PRODUCT NUMBERING SYSTEM SERIES PHASE. 1: Single Phase 3: Three Phase
|
|
- Posy Bates
- 5 years ago
- Views:
Transcription
1
2 TABLE OF CONTENTS Product Numbering System and Specifications... Safety... Receiving and Inspection... Installation... Electrical...6 Start-up...7 INTRODUCTION The compressor you have purchased is a combination of nearly 00 different components, all of which have been carefully designed, engineered, and assembled to ensure a long, dependable, trouble-free life. The product has been fully tested at the factory and has gone through quality-control inspection prior to shipping. Like any mechanical piece of equipment, it is necessary to fully understand the proper use of its operation and application. Misuse of this valuable and helpful air-power source may shorten its expected life as well as void the warranty of the entire unit. We ask you take the time to read this manual to ensure the dependable service you can expect from your C-Aire compressor. Failure to do so can cause serious injury and may void all warranties. Please take special notice of the safety precautions and safety information contained in this manual. Compressed air, like electricity, is a very helpful and necessary tool. However, compressed air can be extremely dangerous and harmful when it is not understood or is misused. PRODUCT NUMBERING SYSTEM Maintenance...7 Valves and Switches...8 Troubleshooting...8 Warranty...9 Parts Diagram...0 Air Compressor Basics... Back Cover S60 R LD P HD SD 300 LD 60 6 MOUNTING OPTIONS B: Baseplate H: Horizontal Tank V: Vertical Tank (Only on S500 and larger) R: Riser Mount SERIES HD: Heavy Duty (5,000+ hour life) SD: Standard Duty (5,000+ hour life) LD: Light Duty (,000+ hour life) PHASE : Single Phase 3: Three Phase VOLTAGE 5 (Available on S500 and smaller) 30 (08/30v) 60 ADDITIONAL OPTION P: Prewired Power Cord S: Prewired Magnetic Starter U: 30-0psi Adjustable Pressure Switch D: Digital Pressure Switch (Also available in PU and SU) Not all combinations are possible. WHISPER QUIET - 60dB DESIGNED TO LAST YEARS BASED ON RUN TIME OF 30 MINUTES PER DAY SPECIFICATIONS: Must be used with an Air Pressure Maintenance Device. HP SYSTEM CAPACITY PRESSURE SWITCH CFM PUMP CYLINDERS VOLTS PHASE RUNNING AMPS BREAKER SIZE TANK SIZE OUTLET DIMENSIONS WEIGHT 0 PSI 60 GALLONS 0 PSI 50 GALLONS 0 PSI 00 GALLONS OFF CYLINDER, OIL FREE CERAMIC COMPOSITE AMP RECOMMENDED GALLON / NPT 36 x0.5 x7 LBS.
3 SAFETY DEFINITIONS DANGER: Indicates a hazardous situation that, if not avoided, will result in death or serious injury. WARNING: Indicates a hazardous situation that, if not avoided, could result in death or serious injury. CAUTION: Indicates a situation that will or could cause minor injury or property damage. GENERAL PRECAUTIONS Read the Owner s Manual before operating. DANGER: Do not use compressed air for breathing air applications. Beware of high voltage: disconnect lockout/tagout electric supply before servicing. Ground compressor per codes. WARNING: Beware of high-pressure air: do not bypass, modify, or remove safety/relief valves. Beware of hot surfaces: allow unit to cool before servicing. Do not operate with safety guards removed. CAUTION: Never operate the compressor near flammable liquids or vapors. Do not direct the air stream at body. Drain tank air every day to decrease risk of bursting. NOTE: Per UL 50:6.7 C-Aire recommends a maximum of 70% duty cycle for its compressors. RECEIVING AND INSPECTION Upon receipt, inspect the unit for damage and missing parts. If either is apparent, make notations on the delivery receipt, before signing the receipt. Ask the carrier how to file a claim for shipping damages. If concealed damage is discovered (after receiving the unit), notify the carrier within 5 days of receipt, in writing. INSTALLATION SELECTING A LOCATION: C-Aire compressors are to be installed and operated in a clean, dry, well-lighted, and well-ventilated area. Mounts to risers.5 -, concrete or cinder block walls or studs on a drywall. Provide at least 00 cubic feet of fresh air per hp. Ideal operating temperatures are between 3 F and 00 F. Avoid excessively humid areas, as moisture may form in the pump, producing sludge and causing moving parts to wear prematurely. NOTE: The dry pipe/sprinkler system compressor is to be installed in accordance with the Standard for Installation of Sprinkler Systems, NFPA 3. CAUTION: If temperatures consistently drop below 3 F, install the compressor in a heated area. (INSTALLATION CONTINUED ON NEXT PAGE)
4 CAUTION: Never operate the compressor in temperatures below 0 F or above 0 F. WARNING: A compressor should never be used in an area where toxic, corrosive, or volatile agents may be present. MOUNTING THE COMPRESSOR CAUTION: Remove the compressor from the shipping packaging before mounting. CAUTION: Do not mount riser mount unit horizontally. MOUNT TO RISER. Install mounting bracket on riser. Hang unit on mounting bracket 3. Bolt unit to mounting bracket. Install air filter assembly 3 (INSTALLATION CONTINUED ON NEXT PAGE)
5 MOUNT TO CONCRETE WALL C-Aire compressors are to be installed and operated in a clean, dry, well-lighted, and well-ventilated area.. Hammer drill holes for hollow wall anchor. Put hollow wall anchor into holes 3. Tap hollow wall anchor into cinder block with hammer. Attach mounting bracket to wall with bolt and washer into anchor 5. Locate hangers on back of unit 6. Hang unit onto the mounting bracket 7. Slip bolt through unit to mounting bracket 8. Tighten bolt to unit and mounting bracket 9. Install air filter assembly (INSTALLATION CONTINUED ON NEXT PAGE)
6 MOUNT TO CINDER BLOCK C-Aire compressors are to be installed and operated in a clean, dry, well-lighted, and well-ventilated area.. Hammer drill holes for hollow wall anchor. Put hollow wall anchor into holes 3. Tap hollow wall anchor into cinder block with hammer. Attach mounting bracket to wall with bolt and washer into anchor 5. Locate hangers on back of unit 6. Hang unit onto the mounting bracket 7. Slip bolt through unit to mounting bracket 8. Tighten bolt to unit and mounting bracket 9. Install air filter assembly 5 (INSTALLATION CONTINUED ON NEXT PAGE)
7 MOUNT TO DRYWALL C-Aire compressors are to be installed and operated in a clean, dry, well-lighted, and well-ventilated area.. Attach xs to studs in drywall. Attach mounting bracket to wall with bolt and washer into anchor 3. Hang unit onto the mounting bracket. Slip bolt through unit to mounting bracket 5. Tighten bolt to unit and mounting bracket 6. Install air filter assembly INLET AND DISCHARGE PIPING CAUTION: Do not operate unit without inlet-air filtration. If the air is dirty, pipe the filter to a source of clean air. Do not install piping with a diameter lower than that of the pump intake. CAUTION: Do not use PVC plastic in the discharge line. Use hand-welded or threaded steel or copper pipes and cast-iron fittings that are safe for the discharge pressure and temperature. ELECTRICAL WARNING: Compressor installation must be performed by a qualified electrician in accordance with the National Electrical Code (NEC) or the Canadian Electrical Code (CEC), the National Electrical Safety Code (NESC) OSHA code, and/or any local or state codes having precedence. Be sure of proper wire sizing and that the circuit breaker and the distance from the breaker is within suggested range. (ELECTRICAL CONTINUED ON NEXT PAGE) 6
8 Confirm your electrical-supply voltage matches what is required for the motor. WARNING: The compressor must be grounded. Grounding reduces the risk of electric shock. Certain C-Aire models are equipped with a cord that has a grounding wire with a grounding plug. The plug must be plugged into an outlet that is installed and grounded in accordance with all local codes and ordinances. WARNING: Improper installation of the grounding plug will result in a risk of electric shock. When repair or replacement of the cord or plug is required, do not connect the grounding wire to either flat-blade terminal. The insulated wire with a green outer surface and yellow stripes is the grounding wire. NOTE: The installation, electric motor, wiring, and all electrical controls must be in accordance with NFPA National Electric Code, National Electric Safety Code, and state and local codes. WIRING DIAGRAM Failure to abide by the national, state, and local codes may result in physical harm and/or property damage. Wire to motor Wire to power source DANGER: High voltage may cause personal injury or death. Disconnect and lockout/tagout, per OSHA regulation 90.7, all electrical power supplies before opening the electrical enclosure or servicing. Wire to power source DANGER: Never assume a compressor is safe to work on if it is not operating. It could restart at any time. Always disconnect/lockout/tagout before servicing. CAUTION: Dry pipe sprinkler compressor must be wired to a reliable power source to be compliant with NFPA 3. PRESSURE SWITCH START UP NOTE: There is no need to break-in your compressor. It has been tested and run at the factory by qualified personnel. When operating the compressor for the first time, do the following:. Perform an inspection of the compressor to ensure there are no obstructions that might interfere with moving parts.. Release any remaining tank pressure by slowly opening the manual drain valve. 3. Connect the compressor to the power source (the compressor will start). MAINTENANCE WARNING: Before performing maintenance, release air pressure from the system and disconnect/lockout/tagout the main power supply. WEEKLY MAINTENANCE Drain moisture from your air compressor s tank WEEKLY! CAUTION: Open the drain valve slowly to release the moisture, as pressure in the tank can cause the moisture to expel at very high velocity. Check for any unusual noises, vibrations, or permanent leaks from the unloader valve. BIANNUAL MAINTENANCE TURN OFF POWER, and check and tighten all electrical connections. Change air-intake filter(s). Check to make sure all bolts are tight. 7
9 VALVES AND SWITCHES - Compressor will not operate - Knock occurs while compressor is loading - Tank does not hold pressure when compressor is turned off - Tank pressure builds up slowly - Fuses or breaker trip - Reset mechanism cuts out repeatedly. Fuses of proper size blow. TROUBLESHOOTING - No electrical power - Loose wire connections - Pressure switch not making contact - Overload/stripped - Connection rod bearings - Wrist pins, wrist pin bearings - Loose connecting rod nut - Suction and discharge valves - Check all fittings - Make sure Petcock is closed - Faulty Check Valve - Dirty air filter - Blown cylinder head gasket - Worn or broken suction/discharge valves - Air leaks - Wrong size fuses or breaker - Wrong size wire - Motor starting under load - Loose wires - Compressor is being overworked - Variable overload on compressor started needs adjusting - Motor overload - Malfunctioning or improperly adjusted pressure switch or pilot valve - High ambient temperature - Turn on power - Tighten connection - See pressure switch adjustment - Reset overload - Replace rod - Replace complete piston assembly - Tighten - Replace Valves - WARNING: Bleed tank. Disassemble Check Valve assembly, clean or replace faulty parts. - DANGER: Do not disassemble Check Valve with air in tank - Clean or replace filter element - Install new gasket - Install new valve - Tighten joints - Check fuse/breaker size - Check volts/amps - Make sure pump is unloading when compressor shuts off - Check electrical connections - Compressor should not run more than 6 out of 0 minutes on average - Call C-Aire - Shut down immediately to avoid damage - Adjust or replace - Provide ventilation - Overheating compressor - Poor ventilation - Relocate compressor - Internal pump problem - Have unit serviced - Water in air receiver - Condensation in the air receiver - Drain daily or install an Automatic Tank Drain 8
10 WARRANTY C-Aire Inc. warrants its compressors to be free from defects in material and workmanship subject to the following provisions: STANDARD WARRANTY DURATION: months from date of purchase. WHAT THE WARRANTY COVERS DURING THE WARRANTY DURATION: All components on the compressor except for those items listed in the section titled What is excluded from warranty coverage. WHAT IS EXCLUDED FROM THE WARRANTY COVERAGE: A) Air intake filters and compressor oil, which are maintenance items. B) Failure due to improper installation, including absence of mounting pads, and insufficient power. C) Oil leaks will be covered under warranty for a period of 60 days from purchase. D) Freight damaged items. (REJECT THE SHIPMENT or note damage on Bill of Lading) E) Any labor, freight or transportation charges that are not pre-approved by C-Aire. F) Labor charges incidental to the installation, electrical connections, repair, service, adjustment, removal, or replacement. G) Misuse or abuse. H) C-AIRE HAS NO OBLIGATION UNDER THESE WARRANTIES OR OTHERWISE (REGARDLESS OF THE FORM OF ACTION) FOR SPECIAL, INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES, INCLUDING WITHOUT LIMITATION, LOSS OF USE, LOST PROFITS, LOST INCOME, WHETHER SUFFERED BY THE BUYER OR A THIRD PARTY. HEAVY DUTY SERIES WARRANTY: C-Aire warrants its compressor pumps from the Heavy Duty Series (noted by the HD in its part number) to be free from defects in material and workmanship for a period of 36 months from the date of purchase. The 3 year warranty for HD units only covers the compressor pump. All other components are covered under the Standard Warranty Duration, which is months from date of purchase. C-AIRE S OBLIGATIONS: C-Aire will repair or replace, at C-Aire s option, defective parts, pay reasonable labor costs of replacing or repairing the defective part, and pay ground freight for the return of defective parts and shipment of the replacement part(s). ALL LABOR AND FREIGHT MUST BE PRE-APPROVED AND ARRANGED BY C-AIRE. PURCHASER S OBLIGATION: ) Properly install and start up the compressor using the checklist located at the back of this Owner s Manual. (Keep Installation Checklist for future reference.) ) Ensure the compressor is sized properly for the application. (the compressor should run no more than 7 out of 0 minutes on average.) 3) Maintain proof of purchase and Installation Checklist. WARRANTY CLAIMS: Please contact C-Aire at or Please have your completed Installation Checklist available. 9
11 ITEM NO. PART NO. RM 60R-000 RM 60R RM 60R-0003 RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R-000 RM 60R-00 RM 60R-00 3 RM 60R-003 RM 60R-00 5 RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R-000 RM 60R-00 RM 60R-00 3 RM 60R-003 RM 60R-00 5 RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R-000 RM 60R-00 RM 60R-00 3 RM 60R-003 RM 60R-00 6 RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R RM 60R-006 ITEM NO Description QTY Plastic Cover Filter Cover Filter Element Filter Base O Ring ø5 Gasket Pipe Hexagon Socket Screw Cylinder Head Gasket M*8 Screw Locking Block Valve Plate Valve Disc Valve Plate Washer M*8 Screw O Ring Cylinder M6*6 Screw 56 ITEM NO Air Compressor Exploded Parts Diagram S60R-LD-5P Description QTY ITEM NO. Description QTY ITEM NO. Description QTY Pressure Plate Piston Ring Connecting Rod Bearing Hexagon Socket Screw Crankcase Bushing Capacitor M*60 Stud ø Spring Washer Protecting Cover Self-tapping Screw Fan Blade ø Outside Spring Crank Throw Stator Rotor Bearing ø5 Outside Spring M*0 Screw Capaciter Cover Power Cord Metal Hose Check Valve Strain Relief Copper Tube Pressure Switch Tank Drain Valve Hex Screw Washer Mounting Plate Nut Pressure Gauge Vibration Dampener Washer Nut Mounting Bracket Hex Screw Safety Valve
12 AIR COMPRESSOR BASICS Best practices: Tank mounted, direct driven compressors Tank mounted = reserve supply of air Air Source On 55psi air pressure- Off 0psi air pressure Air Pressure Maintenance Device System pressure 3-0psi Low Pressure High Pressure Dry Pipe Valve Water in system MODEL SERIAL # MFG. # Make a permanent record of the Model and Serial Number of your compressor by filling in the fields above. You ll save time and expense by including this reference identification on replacement part orders. 380 West st Street, Dresser, WI 5009 // // //
Electrical... 5 Start-up... 6 Digital Pressure Switch Programming and Instructions... 7 Maintenance... 8 PRODUCT NUMBERING SYSTEM PHASE SERIES
TABLE OF CONTENTS Product Numbering System and Specifications... Safety... Receiving and Inspection... Installation... Electrical... 5 Start-up... 6 Digital Pressure Switch Programming and Instructions...
More informationPRODUCT NUMBERING SYSTEM SERIES PHASE. HD: Heavy Duty (15,000+ hour life) SD: Standard Duty (5,000+ hour life) LD: Light Duty (2,000+ hour life)
TABLE OF CONTENTS Product Numbering System...1 Safety...2 Receiving and Inspection...2 Installation...2 Electrical...3 Parts Identification...7 Lubrication...9 INTRODUCTION The compressor you have purchased
More informationC T h e A d va n t a g e
C The Advantage TABLE OF CONTENTS Introduction...1 Product Numbering System...1 Safety...2 Receiving and Inspection...2 Installation...2 Electrical...3 Parts Identification...7 Lubrication...9 Start-up...10
More informationSPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI
15 GALLON AIR COMPRESSOR Model: 7678 DO NOT RETURN TO STORE Please call 800-348-5004 for parts and service CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials
More informationSPECIFICATIONS: Tank Size: 80 gallons PUMP RPMs: 1050 CFM: 40PSI; 90 PSI Max Pressure: 150 PSI Thermal overload protection
5HP 80 GALLON TWO STAGE COMPRESSOR Models: 51866, 51870 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement,
More informationAIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST
AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST BELT TYPE IMPORTANT PLEASE MAKE CERTAIN THAT THE PERSON WHO IS TO USE THIS EQUIPMENT CAREFULLY READS AND UNDERSTANDS THESE INSTRUCTIONS BEFORE STARTING
More information6 Litre Oil-Less Air Compressor
Operator s Manual 6 Litre Oil-Less Air Compressor WARNING! Before using this appliance, read the Operator s manual and follow all its safety rules and instructions. SPECIFICATION HWKAC1 1.1 kw / 1.5 HP
More informationPortable Electric/Gas Compressor Operating Instructions
Portable Electric/Gas Compressor Operating Instructions NOTICE Carefully read this instruction manual before attempting to operate this compressor. MODEL # SERIAL # 1-800-551-2406 TABLE OF CONTENTS Safety
More information6L Oil-less Air Compressor 53103
6L Oil-less Air Compressor 53103 Operating Instructions Please read and save these instructions before attempting to assemble, install, operate or maintain the product. Protect yourself and others by observing
More informationPortable Oil Free Silent Series Compressor Operating Instructions
Portable Oil Free Silent Series Compressor Operating Instructions NOTICE Carefully read this instruction manual before attempting to operate this compressor. MODEL # SERIAL # 1-800-551-2406 www.eaglecompressor.com
More informationESE Series Cast Iron Sewage Pumps
Owner s Manual ESE Series Cast Iron Sewage Pumps TABLE OF CONTENTS General Safety.................... 2 Specifications..................... 3 Installation.................... 4 & 5 Troubleshooting...................
More informationSee Warranty on page 6 for important information about commercial use of this product.
See Warranty on page 6 for important information about commercial use of this product. Operating Instructions WL6000 Series Please read and save these instructions. Read carefully before attempting to
More informationHazardous Location Direct-Drive Exhaust Fans. Operating Instructions & Parts Manual
Operating Instructions & Parts Manual EN Hazardous Location Direct-Drive Exhaust Fans Models 10D996 thru 10D999, 10E001 thru 10E007, 10E009 thru 10E020, 32ZN53 and 32ZN54 474904 PLEASE READ AND SAVE THESE
More informationEnclosed Electric Rotary Screw Compressor Installation Guide
Enclosed Electric Rotary Screw Compressor Installation Guide Air compressors should only be installed trained installation personnel call 800-531-9656 to find a local trained. Warning: Read all installation
More informationInstallation and Service Manual for RV33, RV332, RV75, RV752, RV100, RV1002
Rotary Vane Compressors RV Series Installation and Service Manual for RV33, RV332, RV75, RV752, RV100, RV1002 Thank you for purchasing the Stratus RV series rotary vane compressor. This instruction manual
More informationSUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL
SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200
More informationJet Fans. Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY
Jet Fans Instruction Manual READ AND SAVE THESE INSTRUCTIONS WARRANTY All Leader Fan products are guaranteed to be free from defects of workmanship or material and to function satisfactorily when properly
More informationHEAVY DUTY ONBOARD AIR SYSTEM PART NO
IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL FOR FUTURE REFERENCE
More informationPARTS MANUAL FOR TWO STAGE AIR COMPRESSOR
PARTS MANUAL FOR TWO STAGE AIR COMPRESSOR SPECIFICATION CHART Model No. Horsepower Voltage-Single Phase Minimum Branch Circuit Requirement *Fuse Type Air Tank Capacity Approximate Cut-in Pressure Approximate
More informationOPERATING SERVICE MAINTENANCE MANUAL
OPERATING SERVICE MAINTENANCE MANUAL ALL-STAR ROCKING PISTON COMPRESSOR AND VACUUM PUMP Registered by one or more of these standards agency ISO RoHS 9001 Compliant CE Read through carefully and understand
More informationIron Horse Air Compressor part breakdown - IHD6160V1 Item Description IHD6160V1 IHD6160V1 Call for the Customer Service Department.
Iron Horse Air Compressor part breakdown - IHD6160V1 Item Description IHD6160V1 1 Compressor w/ Flywheel CC2065 2 Discharge Tube w/ Fittings TU-23-AL 3 Pressure Gauge PG200-2.5R 4 Air Receiver 60V20X48SPL
More informationSUNC3000 / Item #40885
SUNC3000 / Item #40885 AUTOMATIC POOL COVER PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM 1 . Performance GPH of Water @ Total Feet Of Lift MODEL HP Max. Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. SUNC3000 1/3
More informationSEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL
SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL NOTE! To the installer: Please make sure you provide this manual to the owner of the equip ment or to the responsible party
More informationInstallation and Operating Manual
Installation and Operating Manual OIL-LESS RECIPROCATING AIR COMPRESSOR CIL Series INSTALLATION & OPERATING MANUAL OIL-LESS RECIPROCATING AIR COMPRESSOR TABLE OF CONTENTS Page 1 DESCRIPTIONS A. GENERAL
More informationSHALLOW WELL JET PUMP
SHALLOW WELL JET PUMP MODEL FJ05S 1/2 HP flintandwalling.com ATTACH YOUR RECEIPT HERE Serial Number Purchase Date 1 FW1642 B TABLE OF CONTENTS Product Specifications...2 Safety Information...2 Package
More informationAIR COMPRESSOR IDENTIFICATION
AIR COMPRESSOR IDENTIFICATION For information and questions contact customer service at 1-800-232-1195. Please fill out the information below and have it accessible prior to calling. For the Serial Number
More informationSTAR STOP SHALLOW WELL JET PUMP
SHALLOW WELL JET PUMP MODEL SJ0S / HP STAR starwatersystems.com STOP Questions, problems, missing parts? Before returning to your retailer, call our customer service department at -800-7-0, 7:0 a.m. -
More informationQUALITY MISTING PUMPS
DIRECT DRIVE TOTALLY ENCLOSED FAN COOLED 60200KH, 60201KH MISTING PUMP MANUAL INCLUDING: SPECIFICATION DATA, GENERAL SAFETY PRECAUTIONS, OPERATION, INSTALLATION, PARTS, MAINTENANCE & WARRANTY QUALITY MISTING
More informationElectric Reciprocating Compressor. Installation Guide
Electric Reciprocating Compressor Installation Guide Air compressors should only be installed trained installation personnel call 800-531-9656 to find a local trained. Warning: Read all installation steps,
More informationQUALITY MISTING PUMPS
TOTALLY ENCLOSED DIRECT DRIVE 60030KH, 60031KH, 60050KH, 60051KH 60100KH, 60101KH, 60150KH, 60151KH MISTING PUMP MANUAL INCLUDING: SPECIFICATION DATA, GENERAL SAFETY PRECAUTIONS, OPERATION, INSTALLATION,
More informationInstallation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752
Rocking Piston Compressors Installation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752 Thank you for purchasing the Stratus SRC series rocking piston compressor. This instruction manual
More informationHALLMARK INDUSTRIES INC
Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge
More informationNECO Pumping Systems
INSTALLATION OPERATION & MAINTENANCE INSTRUCTIONS For Your NECO Pumping Systems PACKAGED CIRCULATING SYSTEM THIS COMPLETELY ASSEMBLED, TESTED, PACKAGED CIRCULATING SYSTEM IS OF THE HIGHEST QUALITY AND
More informationUser s Manual D-Series Blowers and Exhausters
User s Manual D-Series Blowers and Exhausters D05-1 ½ HP TEFC 115/230 VOLTS, 1 PH D05-3 ½ HP TEFC 208/230/460 VOLTS, 3 PH D10-1 1 HP TEFC 115/230 VOLTS, 1 PH D10-3 1 HP TEFC 208/230/460 VOLTS, 3 PH D15-1
More informationEND SUCTION CENTRIFUGAL PUMPS
OWNERS GUIDE TO INSTALLATION AND OPERATION FW000 009 Supersedes 07 END SUCTION CENTRIFUGAL PUMPS READ THESE INSTRUCTIONS CAREFULLY Read these installation instructions in detail before installing your
More informationPump Owner s Manual. PLEASE! Read All Instructions Carefully Before Installing Pump
Pump Owner s Manual PLEASE! Read All Instructions Carefully Before Installing Pump Guarantee Associate Engineering Corporation warrants that pumps purchased from them will be free of defects in material
More information24/3000H-3PH 24/4500H-3PH 24/6000H-3PH
Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 120015D OWNERS
More informationADI-125/750 ADI-125/1500 ADI-125/2500
Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121094B OWNERS
More informationGRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13
GRINDER PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #2701-0005 Español p. 13 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP
INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT & DIRECT DRIVE XB, HV, HVA, ADD, DDS, DDP The purpose of this manual is to aid in the proper installation and operation of the fans.
More informationAUTO CHARGE D PUMP PLUS
INSTRUCTION MANUAL AUTO CHARGE D PUMP PLUS AUTOMATIC DUAL OUTPUT BATTERY CHARGER Designed Specifically for Vehicles with DDEC ENGINES MODEL #: 091-9-DPP INPUT: 120 Volt, 60 Hz, 8 Amps OUTPUT VEHICLE BATTERY:
More informationAIR COMPRESSOR IDENTIFICATION
AIR COMPRESSOR IDENTIFICATION For information and questions contact customer service at 1-800-232-1195. Please fill out the information below and have it accessible prior to calling. For the Serial Number
More informationINSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS
INSTALLATION, OPERATION AND MAINTENANCE MANUAL WALL EXHAUST FANS BELT DRIVE XBL FANS The purpose of this manual is to aid in the proper installation and operation of the fans. These instructions are intended
More informationCOMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL
COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL Model Number: Service: Serial Number: Installation Date: Installation Location / Application: PLEASE RECORD THE FOLLOWING DATA (Information is
More information40041 Heavy Duty ADA System with Booster Bracket for JK Heavy Duty ADA System with Booster Bracket for 2012 to Current JK
40041 Heavy Duty ADA System with Booster Bracket for 2007-2011 JK 40044 Heavy Duty ADA System with Booster Bracket for 2012 to Current JK 40049 Heavy Duty ADA System Universal for all vehicles (booster
More informationREAD AND SAVE THESE INSTRUCTIONS. High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting
READ AND SAVE THESE INSTRUCTIONS INSTALLATION, OPERATING INSTRUCTIONS & PARTS MANUAL High Velocity Restaurant-Duty Utility Set Belt Driven for Roof Mounting Electrical wiring and connections should be
More informationIon Technologies SHR-HR Submersible Sewage Pump Single Seal, Single Phase, & Three Phase Power
Page 1 of 8 equipment and follow handling procedures per OSHA 29 CFR 1910.1030 when handling equipment after waste water source has been connected to system. WARNING: Risk of Asphyxiation. Installer(s)
More informationModel C230 Pump Controller
MANUAL Model C230 Earthsafe Systems, Inc. 7553 S. Madison Willowbrook, IL 60527 T: (630) 794-5100 F: (630) 794-5106 info@earthsafe.com www.earthsafe.com March 1, 2010 The information contained herein is
More informationStormPro BA Series Sump Pump
Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:
More informationDC to AC Power Inverters
Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com ISO 9001:2000 Certified
More informationAUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL
INSTRUCTION MANUAL AUTO CHARGE D2 AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER Designed Specifically for Vehicles with DDEC ENGINES MODEL #: 091-74-12 INPUT: 120 Volt, 60 Hz, 8 Amps OUTPUT VEHICLE BATTERY 1
More informationREAD THIS MANUAL CAREFULLY BEFORE USING THE PUMP
OWNER S MANUAL Pond Pump READ THIS MANUAL CAREFULLY BEFORE USING THE PUMP Important Notice: This manual contains important information about the installation, operation and safe use of this product. This
More informationDC to AC Power Inverters
Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121114C OWNERS
More informationHEAVY DUTY ONBOARD AIR SYSTEM
HEAVY DUTY ONBOARD AIR SYSTEM PART NO. 10005 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this
More informationWash Prep Systems featuring CAT PUMPS DUPM623 DUPM820 / DUPM820-TS DUPM820D / DUPM820D-TS DUPM1010. Owner s Manual #
Wash Prep Systems featuring CAT PUMPS DUPM623 DUPM820 / DUPM820-TS DUPM820D / DUPM820D-TS DUPM1010 Serial Number: Owner s Manual #0779 072415 Installation Date: Please read and understand this manual.
More informationMOTORIZED FOLDING CAMPER WINCH
OWNER'S MANUAL MOTORIZED FOLDING CAMPER WINCH With 1200lb Lift Capacity The 12 Volt Motorized Folding Camper Winch is used to raise and lower folding campers with the touch of the switch, eliminating hand
More informationD-Series Blowers and Exhausters
Operation and Maintenance Manual D-Series MONOXIVENT - SOURCE CAPTURE SYSTEMS - info@ Oct. - 2015 MONOXVENT BLOWERS AND EXHAUSTERS D05-1 D05-3 D10-1 D10-3 D15-1 D15-3 D20-1 D20-3 D30-1 D30-3 ½ HP TEFC
More informationAIR COMPRESSOR AC5161B AC5161BP. User Manual
AIR COMPRESSOR AC5161B AC5161BP User Manual table of contents table of contents Safety 6 Safety Rules 7 Safety Warnings Overview 11 Basic Air Compressor Components Assembly 13 Assembling the Compressor
More informationMODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM
MODEL NUMBER: 10003 MEDIUM DUTY ONBOARD AIR SYSTEM IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using
More informationAir Operated Double Diaphragm Pump. M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL
Air Operated Double Diaphragm Pump M-Pump ½ Metallic Non Metallic Pump INSTALLATION, OPERATION & MAINTENANCE MANUAL 0.5 I.O.M rev 05. 12/2015 INDEX Title Section Introduction.1 Safety.2 Warranty, General
More informationMEDIUM DUTY ONBOARD AIR SYSTEM
MEDIUM DUTY ONBOARD AIR SYSTEM PART NO. 10003 IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this
More informationINSTALLATION VARIABLE FREQUENCY DRIVE THREE PHASE ALX SERIES SPUN ALUMINUM EXHAUSTERS
SPUN ALUMINUM EXHAUSTER OPERATION INSTRUCTIONS AND PARTS MANUAL READ AND SAVE THESE INSTRUCTIONS The purpose of this manual is to aid in the proper installation and operation of the blowers. These instructions
More informationModels & Options Lubrication. 1/2 Through 10 Hp Models 1Ø 3Ø 1/2 Through 10 Hp Models 1Ø and 3Ø
P U R E A I R T E C H N O L O G Y Climate Control Duplex Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect
More informationUser s Manual and Operating Instructions
User s Manual and Operating Instructions Model Numbers: CL-36-BDF-A, CL-42-BDF-A, CL-48-BDF-A E355088 READ AND SAVE THESE INSTRUCTIONS IMPORTANT: Read and understand all of the instructions in this manual
More informationPHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES
Document No: ICM-IOM Date: 0411 PHANTOM (PH10 and PH12) COMMERCIAL AND INDUSTRIAL SERIES Installation, Operation and Maintenance Manual Please read and save these instructions. Read carefully before attempting
More informationM-3025CB-AV Fuel Pump
SAVE THESE INSTRUCTIONS M-3025CB-AV Fuel Pump Owner s Manual TABLE OF CONTENTS General Information... 2 Safety Instructions... 2 Installation... 3 Operation... 4 Maintenance... 4 Repair... 5 Troubleshooting...
More information24 VOLT AUTOMATIC BATTERY CHARGER PART NO
24 VOLT AUTOMATIC BATTERY CHARGER PART NO. 957732 AC Input: DC Output: Battery Type: Specifications 230 volts, 50 hertz, 3.5 amps, single-phase 24 volts, 20 amps initially tapering to 6 amps 24 volt, 12
More informationAir Storm Fans AS-57EBDBP AS-57EBDBP-HE
AS-57EBDBP AS-57EBDBP-HE Fan 57" Panel Composite BD 1.5HP 230/115V 50/60Hz W/Cone Fan 57" Panel Composite BD 1.5HP 230/115V 50/60Hz W/Cone High Efficiency Table of Contents GrowerSELECT General Page...3
More informationREAD AND SAVE THESE INSTRUCTIONS. Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting
READ AND SAVE THESE INSTRUCTIONS INSTALLATION, OPERATING INSTRUCTIONS & PARTS MANUAL Centrifugal Downblast Exhaust Fan Belt Driven for Roof & Wall Mounting Electrical wiring and connections should be done
More informationRead this entire manual before operation begins.
Read this entire manual before operation begins. Record below the following information which is located on the serial number data plate. Serial No. Model No. Date of Installation Contents Specifications.............
More informationMODEL EGA200 OWNERS MANUAL
3/8 RATCHET WRENCH MODEL EGA200 OWNERS MANUAL www.eaglecompressor.com 1-800-551-2406 READ THE ENTIRE MANUAL BEFORE PUTTING THIS TOOL IN SERVICE Limited Air Tool Warranty Wood Industries, Inc. warrants
More informationInstallation Manual. D3600- Series Duplex Grinder Systems. Contents
Installation Manual 7353000E D3600- Series Duplex Grinder Systems Features: 36 Diameter Fiberglass Tank Available in 48, 60, 72, 84, and 96 heights LSG Single or LSGX 2 Stage 2HP Grinder Pumps Factory
More informationOperating Instructions - Electric Pow'r-Riser Models
ADivisionOf Templeton, Kenly& Co., Inc. Operating Instructions - Electric Pow'r-Riser Models Table of Contents 1.0 Recieving Instructions 2.0 Safety 3.0 Specifications 4.0 Initial Installation Before Operating
More informationGARDEN HOSE UTILITY PUMP
GARDEN HOSE UTILITY PUMP MODEL #HPP360, HPP12V, 473707 MODEL #HPP360, 473707 MODEL #HPP12V ATTACH YOUR RECEIPT HERE Purchase Date SAFETY INFORMATION Please read and understand this entire manual before
More informationWELDING FUME EXHAUSTERS & ARMS
WELDING FUME EXHAUSTERS & ARMS The Ace 75 Series is our flexible and effective line of welding fume exhausters and extraction arms for shops that elect to exhaust their weld fumes outdoors instead of through
More informationStormPro BCV400 Sewage Ejector Pump
Page 1 of 8 Marks & Meanings DANGER: Keep the pump equipment out of the reach of children! Warns that the failure to follow the directions given could cause serious risk to individuals or objects. WARNING:
More information4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause
4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL BEFORE INSTALLING PUMP, BE SURE TO READ THIS OWNER S MANUAL CAREFULLY. CAUTION Fill pump with water before starting or pump will be damaged. The motor on
More informationOWNERS MANUAL JANUARY 2007 ISO
Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121231B OWNERS
More informationQUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE
QUICK START GUIDE OWNER S MANUAL SAFETY, INSTALLATION, OPERATION & PARTS AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL 877-278-2797 DO NOT RETURN TO STORE! WARNING This equipment must be installed
More informationLAWN SPRINKLER, IRRIGATION PUMP
LAWN SPRINKLER, IRRIGATION PUMP MODEL #, SP0P, SP5P, SP20P, EL0P, EL5P, EL20P SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.
More informationUtility Distribution Systems Installation, Operation, and Maintenance Manual
Utility Distribution Systems Installation, Operation, and Maintenance Manual RECEIVING AND INSPECTION Upon receiving unit, check for any interior and exterior damage, and if found, report it immediately
More informationSEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14
SEWAGE PUMP Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. MODEL #1261-0001 Español p. 14 ATTACH YOUR RECEIPT HERE Serial Number Purchase Date Questions, problems, missing parts?
More informationVariable Speed Misting Pump Totally Enclosed Direct Drive MODEL HDE-1PH-230VFD
Variable Speed Misting Pump Totally Enclosed Direct Drive MODEL 60100-HDE-1PH-230VFD SAFETY, GENERAL INFORMATION, ELECTRICAL DEFINITIONS WARNING CAN cause DEATH, SEVERE INJURY or substantial property damage.
More informationOWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP
Model 54011-0 OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475
More information110 Volt/12 Volt Portable Inflator
110 Volt/12 Volt Portable Inflator Owner s Manual WARNING: Read carefully and understand all ASSEMBLY AND OPERATION INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety
More informationDimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company
Manufacturer of Dimensions Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com OWNERS MANUAL April
More informationAUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:
INSTRUCTION MANUAL AUTO CHARGE 4000 AUTOMATIC DUAL OUTPUT BATTERY CHARGER MODEL #: 091-89-12 INPUT: 120 Volt, 50/60 Hz, 8 Amps OUTPUT BATTERY CHARGER: 40 Amps OUTPUT BATTERY SAVER: 5 Amps File: IM_091-89-12_reve.indd
More informationHigh Frequency SineWave Guardian TM
High Frequency SineWave Guardian TM 380V 480V INSTALLATION GUIDE FORM: SHF-IG-E REL. January 2018 REV. 002 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation
More informationDISCLAIMER: SPECIFICATIONS:
5HP 80 GALLON TWO STAGE COMPRESSOR Models: 7654 CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials such as wood, paint, metal, concrete, cement, or other
More information1/4 ANGLE DIE GRINDER
1/4 ANGLE DIE GRINDER MODEL EGA500 OWNERS MANUAL www.eaglecompressor.com 1-800-551-2406 READ THE ENTIRE MANUAL BEFORE PUTTING THIS TOOL IN SERVICE Limited Air Tool Warranty Wood Industries, Inc. warrants
More informationMODEL EGA130 OWNERS MANUAL
3/4 IMPACT WRENCH MODEL EGA130 OWNERS MANUAL www.eaglecompressor.com 1-800-551-2406 READ THE ENTIRE MANUAL BEFORE PUTTING THIS TOOL IN SERVICE Limited Air Tool Warranty Wood Industries, Inc. warrants air
More informationPremium Supply. Direct Push. Models PCK-3530-DP PCK DP PCK-530-DP. Operator s Manual and Installation Instructions
Direct Push Models PCK-3530-DP PCK-3530-2DP PCK-530-DP Operator s Manual and Installation Instructions Premium Supply 2038 West Interstate 30 866-934-0777 Proud members of: and June 20, 2018 Table of Contents
More informationHigh Pressure Pump Units featuring CAT PUMPS DUPM550 & DUPM570
High Pressure Pump Units featuring CAT PUMPS DUPM550 & DUPM570 Serial Number: Owner s Manual #0789 122315 Installation Date: Please read and understand this manual. Store in safe location for future reference.
More informationAir Compressor. Owner s Manual
35 WARNING! READ AND UNDERSTAND ALL SAFETY PRECAUTIONS IN THIS MANUAL BEFORE OPERATING. FAILURE TO COMPLY WITH INSTRUCTIONS IN THIS MANUAL COULD RESULT IN PERSONAL INJURY, PROPERTY DAMAGE, AND/ OR VOIDING
More informationINSTALLATION OPERATING MAINTENANCE INSTRUCTIONS
INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS ROTARY VANE -00% OIL-FREE VACUUM PUMP OR COMPRESSOR 0 to 08 0 to 0 3060 to 3080 C CE RoHS ISO 9000:00 300 to 30 Read through carefully and understand these
More informationAtlas PV-9WP Addendum
Atlas PV-9WP Addendum 9,000 lb. Capacity Two-Post Overhead Lift The Atlas PV-9WP above ground hoist is 6 inches wider than the Atlas PV-9P, giving it an overall width of 141 (11 9 ) and a drive thru width
More informationKING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.
KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC. WARRANTY & SERVICE INFORMATION 1-YEAR LIMITED WARRANTY FOR THIS 950W
More informationPORTABLE AIR COMPRESSOR
PORTABLE AIR COMPRESSOR AC206 USER MANUAL BEPOWEREQUIPMENT.COM Introduction 4 Using the Operator s Manual 4 Specifications Product Identification 5 Record Identification Numbers Safety 6 Receipt and Inspection
More informationRead this entire manual before operation begins.
Read this entire manual before operation begins. Record below the following information which is located on the serial number data plate. Serial No. Model No. Date of Installation Contents Specifications.............
More informationMODEL EGA220 OWNERS MANUAL
1/4 MINI RATCHET MODEL EGA220 OWNERS MANUAL www.eaglecompressor.com 1-800-551-2406 READ THE ENTIRE MANUAL BEFORE PUTTING THIS TOOL IN SERVICE Limited Air Tool Warranty Wood Industries, Inc. warrants air
More information