Fiber Optic Splice Module
|
|
- Leslie Booth
- 5 years ago
- Views:
Transcription
1 .COM 2016 O 24 Fiber Optice Splice Module in open position INSTALLATION INSTRUCTIONS Fiber Optic Splice Module Part Numbers: FHD-FOSMF, FHD-FOSMM 12 Fiber Optice Splice Module in open position Contents: CAUTION: Fiber optic cable is sensitive to excessive pulling, bending and crushing forces. Consult the manufacturer s cable specification sheet for the specific cable in use. WARNING: UNMATED CONNECTORS MAY EMIT INVISIBLE LASER RADIATION. DO NOT LOOK DIRECTLY INTO THE END OF THE CONNECTOR. DO NOT INSPECT WITH MAGNIFYING DEVICES. MAINTAIN CAP ON UNMATED CONNECTORS. Care should be taken when opening and closing fully loaded drawer in order to protect fiber components. ASSEMBLY VIEW (24 Fiber Optice Splice Module Shown) Figure 1 Page 1 of 6
2 .COM 2016 INSTALLATION INSTRUCTIONS 12 Fiber Optice Splice Module Figure 2 Page 2 of 6
3 .COM 2016 INSTALLATION INSTRUCTIONS Typical cable routing for 12 Fiber Optice Splice Module or 24 Fiber Optice Splice Module Route sub-unit tube(s) through retention bridge as shown. Route 900µm buffered fiber from the trunk cable and splice to pigtail. Use enough cable length, approximately 1.2m (47") to ensure one complete loop of individual fibers around FHD-FOSM slack spools. Pigtails leading to FAPs should be a minimum of 1m (39.4"). Figure 3 Figure 4 Page 3 of 6
4 .COM 2016 INSTALLATION INSTRUCTIONS FHD-1UFCE and FHD-2UFCE Fiber Optic Splice Module Installation If 4 or 8 FHD-FOSMs are to be installed in the FHD-1UFCE or FHD-2UFCE, side latches on top module must be broken off to close the enclosure drawer. shown. Once mounted, fully seat fasteners to secure. Figure 5 Fully extend drawer to ensure proper amount of slack is used. Finish splicing in each FHD-FOSM before adding/stacking subsequent FHD-FOSMs. (cables omitted for clarity) Figure 5A Page 4 of 6
5 .COM 2016 INSTALLATION INSTRUCTIONS FHD-4UFCE Fiber Optic Splice Module Installation Place FHD-FOSM holder over M4 studs on sliding tray,secure with M4*8 hex nut. Remaining FHD-FOSMs are stacked on top of each other and snap in place after termination of lower tray. shown. Once mounted, fully seat to secure FAPs. Fully extend tray to ensure proper amount of slack is used. Finish splicing in each FHD-FOSM before adding/stacking subsequent FHD-FOSMs. (cables omitted for clarity). Figure 6 Page 5 of 6
6 .COM 2016 INSTALLATION INSTRUCTIONS FHD-2UFRME and FHD-4UFRME-N Fiber Optic Splice Module Installation Place first FHD-FOSM over M4 studs on sliding tray, and secure with M4*8 hex nut. Remaining FHD-FOSMs are stacked on top of each other and snap in place after termination of lower tray. shown. Once mounted, fully seat to secure FAPs. Figure 7 FHD-1UFMT-N and FHD-2UFMT Fiber Optic Splice Module Installation To remove top cover (not shown), remove screw at rear of enclosure, slide cover back and off. Utilizing double stick tape on underside, place first FHD-FOSM into tray. Remaining FOSMs are stacked on top of each other and snap in place after termination of lower tray. Figure 8 If 4 FHD-FOSMs are to be installed in the FHD-1UFMT-N, side latches on top module must be broken off to close enclosure drawer. shown. Once mounted, fully seat to secure FAPs. Page 6 of 6
Opticom Rack Mount Fiber Enclosures
Opticom Rack Mount Fiber Enclosures Part Numbers: FRME1U, FRME2U Panduit Corp. 2011 INSTALLATION INSTRUCTIONS FRME1U FRME2U Contents - (#) indicates FRME2U quantity 1 - ENCLOSURE 2 - MOUNTING BRACKETS
More informationPanView iq (PViQ) Fiber Tray
PVQ-FMT PanView iq (PViQ) Fiber Tray Part Number: PVQ-FMT Contents: 1 - FIBER TRAY (HOUSING & DRAWER) 6 - #12-24 x 1/2" SCREWS 6 - M6 x 1.0 x 16 SCREWS 2 - STRAIN RELIEF BRACKETS 2 - #10-32 BLACK HEX NUTS
More information8400 Series Fiber Distribution System
8400 Series Fiber Distribution System Instructions January 1997 34-7041-4699-1-A 1 Contents: 1.0 General... 3 2.0 System Components... 4 3.0 System Engineering... 5 4.0 Hardware Installation... 7 5.0 Cable
More informationFiber Connector Shelf (CCS)
Corning Cable Systems Standard Recommended Procedure (SRP) 003-595 Issue 3, May 2007 Page 1 of 6 Fiber Connector Shelf (CCS) Table of Contents 1. General... 1 2. Precautions... 1 3. Components... 2 4.
More informationPretium Wall-Mountable Housing (PWH-02P/-04P/- 06P/-12P and FZB-02P-JB)
1. Precautions 2. Carton Contents Pretium Wall-Mountable Housing OR Fiber Zone Box (FZB-02P-JB) PWH-02P and FZB-02B-JP have: (15 inches) edge grommet (1) Laser warning label (2) Fiber identification labels
More informationSYSTIMAX G2 4U Fixed Rear Access Combination Shelf Instructions
Instruction Sheet 860452176 SYSTIMAX Solutions SYSTIMAX 360 360G2 4U Fixed Rear Access Combination Shelf Instructions General The SYSTIMAX 360 360G2 4U rear access fiber optic combination shelf mounts
More informationEnvironmental Distribution Center (EDC-06P-NH)
Corning Cable Systems Standard Recommended Procedure (SRP) 003-545 Issue 4, July 2004 Page 1 of 13 Environmental Distribution Center (EDC-06P-NH) 1.2 To purchase any accessories that are sold separately,
More informationINSTALLATION INSTRUCTIONS
144F TABLE OF CONTENTS GENERAL... 2 SPECIFICATIONS... 2 PACKAGE CONTENTS... 2 PACKAGE CONTENTS: ACCESSORIES... 3 REQUIRED TOOLS... 3 ADD-ON COMPONENTS... 3 CABINET MOUNTING WALL MOUNT BRACKET ATTACHMENT...
More informationINSTALLATION INSTRUCTIONS
TABLE OF CONTENTS GENERAL...2 SPECIFICATIONS...2 PACKAGE CONTENTS...2 PACKAGE CONTENTS: ACCESSORIES...3 REQUIRED TOOLS...3 ADD-ON COMPONENTS...3 CLOSURE MOUNTING...3 LOCK AND UNLOCK EXTERIOR DOOR...3 CABLE
More informationFIBER CONNECTOR SAFETY WARNINGS
FIBER CONNECTOR SAFETY WARNINGS SAFETY INFORMATION 1. Always wear safety glasses. 2. Isopropyl alcohol is flammable and may cause eye irritation. In case of contact with eyes, flush with water for at least
More informationFiber optic splice closure
FOSC-450A I N S T A L L A T I O N I N S T R U C T I O N TC-772-IP Rev A, Mar 2017 www.commscope.com Fiber optic splice closure Content 1 Introduction 2 General 2.1 Kit content 2.2 Tools 2.3 Accessories
More informationInstructions for Use - Opt-X 1000i Enclosure
5R1UM-F03, 5R1UM-S03, 5R2UM-F06, 5R2UM-S06, 5R3UM-F09, 5R3UM-F12, 5R4UM-F12, 5R4UM-F15 Instructions for Use - Opt-X 1000i Enclosure 5R1UM-*03 5R2UM-*06 5R3UM-F** 5R4UM-F** Page 1 of 8 Leviton Network Solutions,
More informationOFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION
OFS 400A FIBER OPTIC INTERCONNECT 636-299-109-01 Instruction Sheet UNIT (FOIU) Comcode 846 586 212 INSTALLATION This instruction sheet covers the 400A1 (106266901) and 400A2 (106414170) Fiber Optic Interconnect
More informationSYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions
Instruction Sheet 860564707 Issue 2, January 2014 SYSTIMAX Solutions SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions General The SYSTIMAX 360
More informationPanduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF
Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF242430 and ZDF242430-6 Table of Contents Figure 1: Industrial Distribution Frame (IDF) Equipment Elevation
More informationSYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions
Instruction Sheet 860564699 Issue 2, January 2014 SYSTIMAX Solutions SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions General The SYSTIMAX 360 fiber optic
More informationFiber Splice Panel Rack Mount User Manual
Fiber Splice Panel Rack Mount User Manual Content Page INTRODUCTION... 1 Revision History... 1 List of Changes... 1 Trademark Information... 2 Admonishments... 2 1. DESCRIPTION... 2 A. Product Definition
More informationPanduit PreConfigured ZDF48-RA Industrial Distribution Frame (IDF) Installation Instructions
Panduit PreConfigured ZDF48-RA Industrial Distribution Frame (IDF) Installation Instructions Figure 1: Industrial Distribution Frame (IDF) Equipment Elevation V00028CA Rev01 Page 1 of 14 Table of Contents
More informationSYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions
Instruction Sheet 860445121 Issue 2, December 2012 SYSTIMAX Solutions SYSTIMAX 360 ipatch G2 High Density Sliding Fiber Shelf Instructions General The SYSTIMAX 360 ipatch G2 High Density Sliding Fiber
More informationUniversal Splice Tray Installation Instructions
Universal Splice Tray Installation Instructions Table of Contents General Product Information... 1.0 Safety Precautions... 2.0 Package Contents... 3.0 Installing the Product... 4.0 Tower Mounting... 5.0
More informationSYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions
Issue 6, June 2014 SYSTIMAX 360 ipatch InstaPATCH Fiber Shelf Instructions General The SYSTIMAX 360 ipatch InstaPATCH fiber shelf is a SYSTIMAX approved product and is available in a sliding configuration
More informationCOYOTE STP (Service Termination Point)
JANUARY 2017 COYOTE STP (Service Termination Point) Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.
More informationSplice Trays. features and benefits. specifications. A LANscape. Solutions Product. Splice Capacity
features and benefits Metal trays powder coated Clear plastic covers Fiber loop retention Positive holding action specifications SPECIFICATION SHEET LAN-331-EN PAGE 1 Ruggedness and durability Fiber visibility
More informationPatching & Splicing Shelf. 4.2 Side cable termination directly on the shelf using cable termination plate. IFC cable/break-out cable
FIST-GPS2/GPST-12 I N S T A L L A T I O N I N S T R U C T I O N Patching & Splicing Shelf Contents 1 Introduction 2 General 2.1 Kit contents 2.2 Tools 2.3 Optional accessories 3 Installation of the shelf
More informationCOYOTE STP (Service Termination Point)
March 2019 COYOTE STP (Service Termination Point) Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED TM product before application.
More informationLPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions
LPC Series Fiber Panel 12/24 Fiber Rack-Mount Enclosure Installation Instructions ADCP-92-129 Issue 1 6/2010 Content Page INTRODUCTION.............................................................................
More informationFL2000 Termination/Splice Panels User Manual
FL2000 Termination/Splice Panels User Manual Content Page INTRODUCTION... 1 Revision History... 1 List of Changes... 1 Trademark Information... 2 Related Publications... 2 Admonishments... 2 General Safety
More informationFOSC-400D5 INSTALLATION INSTRUCTION. Fibre Optic Splice Closure with integrated organiser system
FOSC-400D5 INSTALLATION INSTRUCTION Fibre Optic Splice Closure with integrated organiser system 1 General 1.1 The installation instruction describes the necessary steps to install the FOSC-400D5. The
More informationCORNING. CamSplice User Guide 2. TOOLS AN MATERIALS 1. GENERAL 3. LOADING CAMSPUCE INTO TOOL
CORNING CamSplice User Guide pin 006-038, Issue 13 1. GENERAL This procedure outlines the use of the Cam Splice and TKT-1 00-01 and TKT-100-02 tool kit for splicing optical fibers (see Table 1). This document
More informationINSTALLATION INSTRUCTIONS
TABLE OF CONTENTS GENERAL...2 SPECIFICATIONS...2 PACKAGE CONTENTS...2 PACKAGE CONTENTS: ACCESSORIES...3 REQUIRED TOOLS...3 ADD-ON COMPONENTS...3 CABINET MOUNTING HAND-HOLE OR VAULT...3 CABINET MOUNTING
More informationipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions
Instruction Sheet 860463090 Issue 3, December 2012 SYSTIMAX Solutions ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions General These instructions describe how to install ipatch Ready
More informationCOYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation
NOVEMBER 2016 COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED
More informationFIST-FPS. Front Patching Shelf. Contents. 1 Introduction. 3 Installation of the shelf. 2 General. 1 Introduction
FIST-FPS I N S T A L L A T I O N I N S T R U C T I O N Front Patching Shelf Contents 1 Introduction 2 General 2.1 Kit content 2.2 Tools 3 Installation of the shelf 3.1 Side cable termination directly on
More informationOFS Fitel LST1U-072/7 and LSTLW Instruction Sheet (LaserWave) Fiber Optic Comcode: Termination Shelf Installation
OFS Fitel LST1U-072/7 and LSTLW 636-299-103-5 Instruction Sheet (LaserWave) Fiber Optic Comcode: 845 866 409 Termination Shelf Installation Preface This instruction sheet covers the installation of the
More informationZ22C-** Preconfigured Network Zone System
Z22C-** Preconfigured Network Zone System Page 1 of 12 TABLE OF CONTENTS Overview of Products Specs / Tools Needed Safety Information / Warnings Wall Mounting Bracket Installation Wall Mounting Removable
More informationSYSTIMAX SMB-4-3/4, SMB-8-1/2 Shelf-Mounted Cable Bracket Kits and 1000G2-XCPB Expanded Cable Protector Kit
Instruction Sheet 860380799 SYSTIMAX Solutions SYSTIMAX SMB-4-3/4, SMB-8-1/2 Shelf-Mounted Bracket Kits and 1000G2-XCPB Expanded Protector Kit General The SYSTIMAX SMB-4-3/4 and SMB-8-1/2 shelf mounted
More informationNEMA-Rated Fiber Optic Wallmount Enclosure. Protects your fiber cabling in a damp environment.
JPM4001A-R2 NEMA-Rated Fiber Optic Wallmount Enclosure Protects your fiber cabling in a damp environment. BLACK BOX Single rubber gasket door has a hex nut security lock. Cable enters or exits the enclosure
More informationLightLink Fiber Optic Splice Trays
LightLink Fiber Optic Splice Trays AFL s LightLink series of Fiber Optic Splice Trays offers a variety of unique and flexible splice and storage possibilities. They are available in industry standard config
More informationSplice Only Sub Assembly. Follow all local safety regulations related to optical fibre plant elements
FIST-SOSA I N S T A L L A T I O N I N S T R U C T I O N Splice Only Sub Assembly Single element sub-assemblies Single circuit sub-assemblies Ribbon sub-assemblies FIST-SOSA-2SE8/2- X FIST-SOSA-4SC2/0-
More informationLSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL CUSTOMER SERVICES REFERENCES TOOLS REQUIRED
OFS Fitel LSS1U-144/7 Fiber Optic 636-99-103-1 Instruction Sheet Splice Shelf Installation COMCODE 845 866 474 LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL This instruction sheet provides
More informationMultilink s Family of Wall Mount Enclosures
Multilink s Family of Wall Mount Enclosures The Multilink family of wall mounted optical termination enclosures are designed to provide solutions for both the interconnection of patch cabling and a combination
More information12-Inch Hybrid Fiber Access Terminal Installation Instructions
12-Inch Hybrid Fiber Access Terminal Installation Instructions 19683-A Content Page 1 PRODUCT DESCRIPTION.................................................................. 2 2 PRODUCT FUNCTION.....................................................................
More informationOFS LSS1U-864/ Instruction Sheet Fiber Optic Comcode: Splice Shelf Installation
OFS LSS1U-864/9 636-299-103-49 Instruction Sheet Fiber Optic Comcode: 848 461 620 Splice Shelf Installation LSS1U-864/9 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL This instruction sheet provides procedures
More informationCOYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure
AUGUST 2013 COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED TM product
More informationPLEASE READ THIS INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION
INSTALLATION INSTRUCTIONS PART NUMBER: L0SXC000 DESCRIPTION: 09 ASCENT TRAILER HITCH PLEASE READ THIS INSTRUCTIONS CAREFULLY, BEFORE YOU START INSTALLATION SAFETY PRECAUTION: When installing Trailer Hitch,
More informationINSTALLATION INSTRUCTIONS
TABLE OF CONTENTS GENERAL...2 SPECIFICATIONS...2 PACKAGE CONTENTS...2 PACKAGE CONTENTS: ACCESSORIES...3 REQUIRED TOOLS...3 ADD-ON COMPONENTS...3 CABINET MOUNTING HAND-HOLE OR VAULT...3 CABINET MOUNTING
More informationInstructions for Use - Opt-X Ultra Enclosure Directives Enceintes Opt-X Ultra MC Instrucciones de Uso Caja Opt-X Ultra MR
5R1UH-S03 5R2UH-S06 5R4UH-S12 Instructions for Use - Opt-X Ultra Enclosure Directives Enceintes Opt-X Ultra MC Instrucciones de Uso Caja Opt-X Ultra MR 5R1UH-S03 5R2UH-S06 5R4UH-S12 Page 1 of 26 Leviton
More information19 1HU Splicing and Front Patching Shelf
FOMS-FPS-O-XXXX-XX I N S T A L L A T I O N I N S T R U C T I O N 19 1HU Splicing and Front Patching Shelf Contents 1 Introduction 2 General 2.1 Characteristics 2.2 Kit contents 2.3 Tools 3 Installation
More informationBe sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.
5 NOVEMBER 2010 COYOTE Dome 9.5 x 28 Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application. 1. 7. 2. 4. 10.
More informationMini-OTE 400. Mini-OTE 400. Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide.
Mini-OTE 400 INSTALLATION INSTRUCTION TC-1335-IP Rev C, March 2017 www.commscope.com Mini-OTE 400 Content 1 General 1.1 General product information 1.2 Cable types 1.3 Symbols in this guide 2 Tools Required
More informationEnglish. 1 of 5. Parts Supplied:
English Fitting Instructions: Daytona 675, Street Triple, Street Triple R, Tiger 800 and Tiger 800XC A96809 - Daytona 675 up to VIN 874, Street Triple and Street Triple R (79 kw models only) A96807 - Daytona
More informationCOYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications
OCTOBER 2017 COYOTE Dome Closure 9.5" x 28" with Transition Tray for High Density Splice Applications Be sure to read and completely understand this procedure before applying product. Be sure to select
More informationMARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits
MARCH 2012 COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before
More informationFIST-GSS2. Fist Generic Splicing Shelf MK2. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails
FIST-GSS2 I N S T A L L A T I O N I N S T R U C T I O N Fist Generic Splicing Shelf MK2 Contents 1 Introduction 2 General 2.1 Kit content 2.2 Tools 2.3 Optional extra s 3 Installation of the shelf 3.1
More informationPart No. PAFULAxxx. Figure 2
Part No. PAFULAxxx - Exhaust Vent -To be installed prior to siding- Remove the trim ring and collar from the vent assembly. Place tape or sealant between the Exhaust Vent and house. Align the tube with
More informationWOC-364 Installation Instructions Ranger XP Heater System
WOC-364 Installation Instructions Ranger 2011-12 XP Heater System Order of installation for a Complete Enclosure Always install the Heater System first if possible NOTE: If installing the Heater System
More informationFIST-GSS2 FIST-GSS3. Fist Generic Splicing Shelf. Contents. 1 Introduction. 2 General. 3 Installation of the shelf. 5 Termination of the pigtails
FIST-GSS2 FIST-GSS3 I N S T A L L A T I O N I N S T R U C T I O N Fist Generic Splicing Shelf Contents 1 Introduction 2 General 2.1 Kit content 2.2 Tools 3 Installation of the shelf 3.1 Mounting the shelf
More informationInstructions for Preparing AFL OPTICAL GROUND WIRE CABLE (HEXACORE CABLE DESIGNS)
Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE IN THE OPTI-GUARD SPLICE ENCLOSURE (HEXACORE CABLE DESIGNS) NOTE: EXCEPT AS MAY BE OTHERWISE PROVIDED BY CONTRACT, THESE DRAWINGS AND/OR SPECIFICATIONS
More informationGENUINE PARTS INSTALLATION INSTRUCTIONS
GENUINE PARTS INSTALLATION INSTRUCTIONS 1. 2. 3. 4. DESCRIPTION: APPLICATION: PART NUMBER: KIT CONTENTS: Accent light Kit Versa Note 999F3 4Z000 - Accent Lighting Kit. 999Q9 AY000 - Accessory Service Connector
More information3M Fiber Dome Closure FDC 10
3M Fiber ome losure F 10 With 3M Fiber Optic Splice Tray 2541 Instructions 1.0 General 2.0 Kit ontents The 3M Fiber ome losure F 10 can accommodate two 1.06" (27 mm) main cables, five 0.71" (18 mm) branch
More informationCOYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure
AUGUST 2012 COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.
More informationFeatures: Use the selection chart below to choose the Splice Case and splice tray organizer which meet the requirements for your application.
FIBERLIGN Organizers For s (Protected and ) and Mechanical s FIBERLIGN Fiber Optic Organizers are designed to help organize, secure, support and protect delicate optical fibers before, during and after
More informationGenesis 2 Measuring System
Genesis Measuring System R 999 Chief Automotive Systems, Inc. GENESIS PARTS INFORMATION If it becomes necssary to order replacement parts or accessories for your Genesis Measuring System, or contact a
More informationFOSC-400A4 INSTALLATION INSTRUCTION
FOSC-400A4 INSTALLATION INSTRUCTION TC-441-IP Rev A, Mar 2017 www.commscope.com Fibre Optic Splice Closure with integrated organiser system 1 General 1.1 The installation instruction describes the necessary
More information2013 Road King CVO FLHRSE5 Detachable Fairing w/ Garmin Zumo 665 Installation Instructions
2013 Road King CVO FLHRSE5 Detachable Fairing w/ Garmin Zumo 665 Installation Instructions 1 1. Turn ignition switch to on position and leave there. This will prevent alarm from going off when you disconnect
More informationReplacing the T320 Cooling System Components. Replacing a T320 Fan Tray. Removing a T320 Front Fan Tray
Replacing the T320 Cooling System Components Replacing a T320 Fan Tray Replacing a T320 Fan Tray on page 1 Replacing a T320 Air Filter on page 5 The T320 router has two front fan trays. The front fan trays
More informationSection 3 FIBERLIGN Closure Series
FIBERLIGN Closure Series: Section 3 Section 3 FIBERLIGN Closure Series Table of Contents Page FIBERLIGN s...3-2 FIBERLIGN Organizers...3-3 FIBERLIGN UNI-CLOSURE...3-8 FIBERLIGN Fiber Safe...3-11 FIBERLIGN
More informationNetwork Zone System. Part Numbers: Z22N-****** Z22R-****
Network Zone System Panduit Corp. 2015 INSTALLATION INSTRUCTIONS Network Zone System Part Numbers: Z22N-****** Z22R-**** Page 1 of 13 TABLE OF CONTENTS Overview of Products Safety Information / Warnings
More informationUniversal Network Zone System Part Numbers: Z23U-****
Universal Network Zone System Part Numbers: Z23U-**** Page 1 of 13 TABLE OF CONTENTS Overview of Products Safety Information / Warnings Specs / Tools Needed Wall Mounting Bracket Installation Wall Mounting
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Accessory Application Publications No. AII 33373 ATTACHMENT KIT (TRUNK MOUNT) 2007 S2000 Issue Date AUG 2006 PARTS LIST Plain washer CD Changer Attachment Kit: P/N 08B26-S2A-100A
More informationBUDI-S-SP. Building distributor. Introduction. Seals. Kit content. Accessories. TC-957-IP Rev A, Feb Wrap around cable seals
BUDI-S-SP I N S T A L L A T I O N I N S T R U C T I O N TC-957-IP Rev A, Feb 2017 www.commscope.com Building distributor Introduction Seals The Budi is a building distributor for a fiber managment system
More informationNetwork Zone System Part Numbers: Z23N-***** Z23R-****
Network Zone System Part Numbers: Z23N-***** Z23R-**** Page 1 of 14 TABLE OF CONTENTS Overview of Products Specs / Tools Needed Safety Information / Warnings Wall Mounting Bracket Installation Wall Mounting
More informationVector Measuring System PARTS MANUAL
Vector Measuring System 00 Chief Automotive Systems, Inc. Parts Ordering Information If it becomes necessary to order replacement parts or accessories for your Vector Measuring System, or contact a service
More informationFIST-GPS2-J. 19 2HU Splicing, Patching and Storage shelf. 5 Fiber routing. 1 Introduction. Contents. 2 General. 6 Storage. 3 Installation of the shelf
FIST-GPS2-J I N S T A L L A T I O N I N S T R U C T I O N 19 2HU Splicing, Patching and Storage shelf Contents 1 Introduction 2 General 2.1 Kit contents 2.2 Tools 2.3 Optional extras 3 Installation of
More informationJANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools
JANUARY 2015 COYOTE Dome Closure 6-1/2" x 17" Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED TM product before application. 1 2
More informationINSTALL INSTRUCTIONS DC C-EV. Installation Instructions: DC C-EV.
INSTALL INSTRUCTIONS DC6-48-60-0-8C-EV Installation Instructions: DC6-48-60-0-8C-EV INSTALL INSTRUCTIONS DC6-48-60-0-8C-EV Contents Section Description Page 1 Copyright 2 1.1 Disclaimer 2 1.2 Warnings
More informationInstallation instructions, accessories. Body kit
Installation instructions, accessories Instruction No 31265373 Version 1.1 5 Part. No. Body kit IMG-256263 Volvo Car Corporation Body kit - 31265373 - V1.1 Page 1 / 42 Equipment A0000162 A0000163 IMG-239664
More informationCOYOTE Dome Closure 6.5" x 22" Kits. COYOTE Dome Closure 6.5" x 22" for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer
JANUARY 2015 COYOTE Dome Closure 6.5" x 22" Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application. 1 2 3 6
More informationTHE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.
THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION. DO NOT APPLY RTV TO THE GASKET WHEN SEALING THE SB01 SPLICE ENCLOSURE. SEE SECTION 18 FOR UPDATED INSTRUCTIONS.
More informationTHE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION.
THE SB01 SPLICE ENCLOSURE NOW INCLUDES A LID GASKET THAT DOES NOT REQUIRE RTV APPLICATION. DO NOT APPLY RTV TO THE GASKET WHEN SEALING THE SB01 SPLICE ENCLOSURE. SEE SECTION 10 FOR UPDATED INSTRUCTIONS.
More informationFibre Optic. Page Fibre Optic Splice Trays 6-9 Fibre Optic Internal Wall Boxes 10 Fibre Optic Splice Closures Closure Accessories 21
Page Fibre Optic plice Trays 6-9 Fibre Optic Internal Wall oxes 10 Fibre Optic plice Closures 11-0 Closure Accessories 1 5 Fibre Optic Fibre Optic plice Trays Hellacurve TM Unique curved design Compact
More informationNo. Tool Vendor P/N. Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL Furukawa FITEL.
TOUCH Plus SC Splice-On Connector for Cordage Standard assembly procedure of TOUCH Plus SC Splice-On Connector is as below. Caution : Wear eye protection glasses when handling optical fibers. 1. Preparation
More informationPower Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables
Power Connection Kit Installation Instructions Terminator DP-M for use with TEK and HTEK series constant watt heating cables For Power Connection (1 Cable), In-Line Splice Connection, or End Termination
More informationCOYOTE Terminal Dome Closure 6.5" x 22"
FEBRUARY 2015 COYOTE Terminal Dome Closure 6.5" x 22" Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.
More informationREVISION DESCRIPTION:
14401 Keil Road NE, Aurora, Oregon, USA 97002 PHONE 503-678-6545 FAX 503-678-6560 www.vansaircraft.com info@vansaircraft.com Service Letters and Bulletins: www.vansaircraft.com/public/service.htm REVISION
More informationE90 AVIN Non-iDrive Head Unit Install with Logic 7 Integration
E90 AVIN Non-iDrive Head Unit Install with Logic 7 Integration Option 1: If you prefer to go an easier route you can order our BMW MOST interface. It would make the install a lot easier and will not require
More informationThree Function Remote Control System with Alarm (Model RCA-3)
Golden RODtronics P.O. Box 146 Golden Colorado 80402-0146 Phone 303-423-8597 Fax 303-420-4575 Three Function Remote Control System with Alarm (Model RCA-3) Congratulations! You have just purchased one
More informationCommScope MULTILAYERED 289-TYPE INSTALLATION INSTRUCTIONS
CommScope MULTILAYERED 289-TYPE 63-460-32-03 BUILDING ENTRANCE PROTECTOR (BEP) Issue 5, February 2004 Material ID 847 364 882 INSTALLATION INSTRUCTIONS General This instruction sheet provides procedures
More informationFiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide)
Fiber Optic Above-Ground) Cross-Connect Enclosure (ACE) Model ACE-200DS Installation Guide) 13536-A Figure 1. ACE-200DS Enclosure With OCM-HD Panels Content Page INTRODUCTION... 2 1 PRODUCT DESCRIPTION...
More informationPHASE 3 POWERSPORTS AUDIO KIT MAVERICK X3 CAN-AM. pg 3 Disassembly, Wire and Amplifier Plate Installation. pg 11 Dash Kit Installation
CAN-AM MAVERICK X3 PHASE 3 POWERSPORTS AUDIO KIT pg 3 Disassembly, Wire and Amplifier Plate Installation pg 11 Dash Kit Installation pg 15 Underseat Subwoofer Installation pg 19 Dash Speaker Pods Installation
More informationOPTICAL FIBER CLOSURE
OPTICAL FIBER CLOSURE INSTALLATION MANUAL STC-HTM Read these instructions carefully and completely before beginning installation. For assistance, contact Technical Support at 82.61.373.7500(South Korea),
More informationFOSC-100 B/H FOSC-100 B2/H
FOSC-100 B/H FOSC-100 B2/H INSTALLATION INSTRUCTION TC-273-IP Rev A, Mar 2017 www.commscope.com Fiber Optic Splice Closure with integrated organizer system 1 1 General 1.1 The installation instruction
More informationOFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions
Instruction Sheet 860385855 Issue 3, June 2013 Uniprise Solutions OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures Instructions General Uniprise OFE-CLS-Type Outside Plant (OSP) Fiber Optic Closures
More informationDIN RAIL FIBER ENCLOSURE
USER MANUAL JPM397A, JPM398A DIN RAIL FIBER ENCLOSURE 24/7 AT OR VISIT BLACKBOX.COM TABLE OF CONTENTS 1. SPECIFICATIONS... 3 2. OVERVIEW... 4 2.1 Description...4 2.2 What s Included...4 2.3 Part Numbers...4
More informationTRUSCAN MEASURING SYSTEM
TRUSCAN MEASURING SYSTEM PARTS MANUAL PB00 08 Chief Automotive Technologies CO987.7 LP068 Rev. - /06/8 PARTS ORDERING INFORMATION If it becomes necessary to order replacement parts or accessories for your
More informationTESLA MODEL S REAR UNDER SPOILER & DIFFUSER SYSTEM
TESLA MODEL S Thank you for purchasing your Unplugged Performance Rear Under Spoiler & Diffuser System for the Tesla Model S! Please read this manual carefully prior to installation. REAR UNDER SPOILER
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Accessory Application Publications No. AII 26320 ATTACHMENT KIT 2004 S2000 Issue Date OCT 2003 PARTS LIST CD Changer Attachment Kit: P/N 08B26-S2A-100A Plain washer Template CD
More informationBEND LIMITING TUBING AND ACCESSORIES
OFBLT Optical Fiber Bend Limiting Tubing The routing of fiber, cable and patch cords in racks and cable nodes is generally a difficult exercise. The resulting spaghetti is prone to transient losses and
More informationGENUINE PARTS INSTALLATION INSTRUCTIONS
GENUINE PARTS INSTALLATION INSTRUCTIONS 1. 2. 3. 4. DESCRIPTION: Accent light Kit APPLICATION: R42H (2011) PART NUMBER: 999F3 AW000 - Universal Accent Lighting Kit. KIT CONTENTS: Item QTY Description Service
More informationSWING DOOR SOFT ENCLOSURE (part# 16733)
800-643-7332 americanlandmaster.com This kit is for use with all fullsize, 2 passenger ALM utility vehicles. SWING DOOR SOFT ENCLOSURE (part# 16733) NOTE TOOLS REQUIRED Drill 1/4 Drill Bit 7/16 Wrench
More information