RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

Size: px
Start display at page:

Download "RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC"

Transcription

1 Characteristics time delay relay 2 functions s..300 h V AC - 2 OC Main Range of product Product or component type Electrical connection Discrete output type Contacts type and composition Component name Time delay type Time delay range [Us] rated supply voltage Voltage range [In] rated current Complementary Product front plate size Control type Housing material Jul 26, 2018 Zelio Time Electronic timing relay 11 pin plug-in sub-base Relay 2 C/O timed contacts AgNi (cadmium free) RE48A A B C Di s s s s h min s h min s h min h min V AC/DC 50/60 Hz Us AC Us DC 5 A 48 x 48 mm Selector switch on front panel Self-extinguishing Repeat accuracy +/- 0.2 % of the maximum setting value conforming to IEC Temperature drift +/ %/ C of the maximum setting value conforming to IEC Voltage drift +/- 0.2 %/V of the maximum setting value at V +/- 1 %/V of the maximum setting value at V 1 Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications

2 Setting accuracy of time delay +/- 5 % of full scale at 25 C conforming to IEC Minimum pulse duration Reset time Pick up duration 20 ms >= 25 ms on de-energisation 55 ms On-load factor 100 % Power consumption in VA Power consumption in W Breaking capacity Minimum switching current Maximum switching current Maximum switching voltage Electrical durability Mechanical durability Output voltage Marking 1.1 VA at 24 V 4.8 VA at 240 V 1.7 W at 240 V 0.5 W at 24 V 1250 VA 100 ma 5 A 250 V AC/DC cycles cycles 240 V at 5 A AC V at 2 A DC V at 1.5 A AC-15 CE Surge withstand 1 kv differential mode conforming to IEC level 3 2 kv common mode conforming to IEC level 3 Mounting support Local signalling Product weight Base mounted: socket Panel mounted: system supplied with the product 1 LED yellow output relay state LED indicator green flashing: relay energised timing in progress LED indicator green on steady: relay energised, no timing in progress 0.14 kg Environment Humidity drift +/ %/%RH of the maximum setting value conforming to IEC Immunity to microbreaks < 10 ms Dielectric strength 1 kv at 1 ma/1 minute conforming to IEC Protection against electric shocks 4 kv class III conforming to IEC kv class III conforming to IEC Standards Product certifications 73/23/EEC 89/336/EEC 93/68/EEC EN /2 EN /2 IEC IEC CSA C-Tick culus GL UL Ambient air temperature for storage C Ambient air temperature for operation C IP degree of protection IP40 housing conforming to IEC IP50 front face conforming to IEC Vibration resistance 0.35 mm Hz conforming to IEC Relative humidity 93 % without condensation conforming to IEC Resistance to electrostatic discharge 6 kv at in contact conforming to EN/IEC level 3 8 kv at in air conforming to EN/IEC level 3 Resistance to electromagnetic fields 10 V/m 26 MHz to 1 GHz conforming to IEC level 3 Resistance to fast transients 2 kv capacitive connecting clip conforming to EN/IEC level 4 4 kv direct conforming to EN/IEC level 4 Immunity to radioelectric fields 10 V at MHz conforming to EN/IEC level 3 Immunity to voltage dips 30 % for 10 ms conforming to EN/IEC

3 60 % for 100 ms conforming to EN/IEC % for 5 s conforming to EN/IEC Disturbance radiated/conducted Class B at MHz conforming to EN (EN group 1) Contractual warranty Warranty period 18 months 3

4 Dimensions Drawings Width 48 mm 4

5 Mounting and Clearance Panel Cut-Out and Mounting Panel Cut-Out n Number of devices mounted side-by-side Mounting Cover positioning and mounting e Panel thickness 1 Protective cover 2 Panel mounting frame 3 Locating screw 5

6 Connections and Schema Wiring Diagram 6

7 Technical Description Function A : Power on Delay Relay Description The timing period T begins on energisation. After timing, the output R closes. T = t1 + t2 + t3 7

8 Technical Description Function B : Interval Relay with Control Signal Description After power-up, pulsing or maintaining control contact C starts the timing T. The output R closes for the duration of the timing period T then reverts to its initial stat T = t1 + t2 + t3 8

9 Technical Description Function C : Off-Delay Relay with Control Signal Description After power-up and closing of the control contact, the output closes. When control contact re-opens, timing T starts. At the end of the timing period, the output r T = t1 + t2 + t3 9

10 Technical Description Function Di : Symmetrical Flasher Relay (Starting Pulse On) Description Repetitive cycle with two timing periods T of equal duration, with output changing state at the end of each timing period T. 10

11 Technical Description Legend Relay de-energised Relay energised Output open Output closed C Control contact G Gate R Relay or solid state output R1/R2 2 timed outputs R2 inst.the second output is instantaneous if the right position is selected T Timing period Ta - Adjustable On-delay Tr - Adjustable Off-delay U Supply 11

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC

RE48AML12MW time delay relay 2 functions s..300 h V AC - 2 OC Characteristics time delay relay 2 functions - 0.02 s..300 h - 24..240 V AC - 2 OC Complementary Product front plate size Control type Housing material Main Range of product Product or component type Electrical

More information

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12

XMLR160M2P05 Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12 Characteristics Pressure sensors XMLR 160bar - G 1/4-24VDC - 2xPNP - M12 Main Range of product Product or component type Pressure sensor type Pressure switch type of operation Device short name Pressure

More information

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal) 86 Timer modules 86 Timer modules for use in conjunction with relay & socket. 86.00T - Multi-function & multi-voltage timer module 86.30T - Bi-function & multi-voltage timer module Complies with EN 45545-2:2013

More information

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12

XMLR400M1N75 Pressure sensors XMLR 400bar - G 1/4-24VDC V - NPN - M12 Characteristics Pressure sensors XMLR 400bar - G 1/4-24VDC - 0..10 V - NPN - M12 Main Range of product Product or component type Pressure sensor type Pressure switch type of operation Device short name

More information

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC ma - NPN - M12

XMLR400M1N26 Pressure sensors XMLR 400bar - 1/4 18 NPT - 24VDC ma - NPN - M12 Characteristics Pressure sensors XMLR 400bar - 1/4" 18 NPT - 24VDC - 4..20 ma - NPN - M12 Main Range of product Product or component type Pressure sensor type Pressure switch type of operation Device short

More information

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets 86 Series - Timer modules Features 86.00 86.30 Timer modules for use in conjunction with relay & socket. 86.00 - Multi-function & multi-voltage timer module 86.30 - Bi-function & multi-voltage timer module

More information

2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets

2 pole, 10 A AC/DC supply non polarized Plug-in for use with 94 series sockets Miniature plug-in timers 7-10 A Plug-in timer.02-2 Pole 10 A.03-3 Pole 10 A.04-4 Pole 7 A Multifunctions Seven time scales, from 0.05 s to 100 h 94 series sockets for 35 mm rail (EN 60715) mount with push-in

More information

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A

RSB1A160B7 interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Characteristics interface plug-in relay - Zelio RSB - 1 C/O - 24 V AC - 16 A Stock Code: Stock - Normally stocked in distribution facility Price*: 4.20 USD Complementary Shape of pin Jul 8, 2015 Main Commercial

More information

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12

XMLRM01G1P25 Pressure sensors XMLR -1 bar - G 1/4-24VDC ma - PNP - M12 Characteristics Pressure sensors XMLR -1 bar - G 1/4-24VDC - 4..20 ma - PNP - M12 Complementary Current consumption Electrical connection Type of output signal Analogue output function Discrete output

More information

XT130B1NAL2 capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m

XT130B1NAL2 capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m Characteristics capacitive sensor - XT1 - cylindrical M30 - brass - Sn 10 mm - cable 2 m Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 159.00 USD Main Range

More information

XXV18B1PAL2 Ultrasonic sensor - M18 metal - Sn 50mm - PNP NO - cable 2m

XXV18B1PAL2 Ultrasonic sensor - M18 metal - Sn 50mm - PNP NO - cable 2m Characteristics Ultrasonic sensor - M18 metal - Sn 50mm - PNP NO - cable 2m Product availability : Stock - Normally stocked in distribution facility Price* : 98.00 USD Main Range of product Sensor type

More information

K50H004UP cam changeover switch - 4-pole A - screw mounting

K50H004UP cam changeover switch - 4-pole A - screw mounting Characteristics cam changeover switch - 4-pole - 60-50 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

K30H001YP cam star-delta switch - 3-pole A - screw mounting

K30H001YP cam star-delta switch - 3-pole A - screw mounting Characteristics cam star-delta switch - 3-pole - 60-32 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing

More information

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED

RUMC22F7 universal plug-in relay - Zelio RUM - 2 C/O V AC - 10 A - with LED Characteristics universal plug-in relay - Zelio RUM - 2 C/O - 120 V AC - 10 A - with LED Product availability : Stock - Normally stocked in distribution facility Price* : 13.79 USD Main Range of product

More information

Surface mounting, flush mounting, and DIN track mounting

Surface mounting, flush mounting, and DIN track mounting Solid-state Timer H3JA Economical, Compact, Plug-in Timer Time limit, ON-delay, operation with automatic resetting. DIN size (36 x 36 mm), fits standard 8-pin sockets. Wide choice of supply voltages: 24,

More information

RPF2AF7 power relay plug-in - Zelio RPF - 2 NO V AC - 30 A

RPF2AF7 power relay plug-in - Zelio RPF - 2 NO V AC - 30 A Characteristics power relay plug-in - Zelio RPF - 2 NO - 120 V AC - 30 A Product availability : Stock - Normally stocked in distribution facility Price* : 12.69 USD Main Range of product Series name Product

More information

Model Number Structure

Model Number Structure Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved

More information

MasterINTERFACE 39 Series - Relay interface modules

MasterINTERFACE 39 Series - Relay interface modules MasterINTERFACE 39 Series - Relay interface modules Common features Space saving 6.2 mm wide Connections for 16-way jumper link Integral coil indication and protection circuit Secure retention and easy

More information

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS

XB5AD33 SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS Characteristics SELECTOR SWITCH 230VAC 2AMP XB5 +OPTIONS Product availability : Stock - Normally stocked in distribution facility Price* : 68.00 USD Main Range of product Product or component type Device

More information

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h) Mechatronic Analog Timer H3AM Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and

More information

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current

More information

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T

46 and 56 Series - Relays for railway applications 8-12 A. Features 46.52T 56.32T 56.34T 46 and 56 Series - Relays for railway applications 8-12 A Features 46.52T 56.32T 56.34T Plug-in power relays: 8 A, 2 pole 12 A, 2 and 4 pole DC coils with extended range Complies with UNI CEI 11170-3 (protection

More information

XMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O

XMLA002A2C11 pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O Characteristics pressure switch XMLA 2.5 bar - fixed scale 1 threshold - 1 C/O Product availability : Non-Stock - Not normally stocked in distribution facility Main Range of product Product or component

More information

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2 Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.

More information

Solid State Relays contactor with Integrated Fuse Type RGC1F

Solid State Relays contactor with Integrated Fuse Type RGC1F Solid State Relays contactor with Integrated Fuse Type RGC1F Solid State Contactor with integrated fuse Zero Cross Switching Operational voltage: 230 VAC and 600 VAC 35mm width Control voltage: 4-32 VDC

More information

XMLA160D2S11 pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O

XMLA160D2S11 pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O Characteristics pressure switch XMLA 160 bar - fixed scale 1 threshold - 1 C/O Product availability : Stock - Normally stocked in distribution facility Main Range of product Product or component type Pressure

More information

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA

VEO. V2TF01 Art.Nr.: V2TF01P Art.Nr.: TECHNICAL DATA P Temperature monitoring (PTC) Short-circuit monitoring Supply voltage 24-240 V AC/DC 1 normally open contact Width 22,5 mm Status indication LED U: Supply voltage LED TFailure: Temperature failure TECHNICAL

More information

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16 Characteristics limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 47.90 USD Main Range

More information

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Characteristics limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx Main Range of product OsiSense ATEX D Series name Standard format Product or component type Limit switch Device short name XCKJ

More information

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP Soft Starter Three-Phase Scroll Compressor Soft Starter Types RSBD Soft starting of 3-phase scroll compressors up to 95Amp Patented auto-adaptive algorithm for optimum inrush current reduction (No user

More information

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1

ILE2K661PC1A1 brushless dc motor V- EtherNet/IP interface - L = 174 mm- 18:1 Characteristics brushless dc motor 24..48V- EtherNet/IP interface - L = 174 mm- 18:1 Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network number

More information

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O

XMLB300D2C11 pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O Characteristics pressure switch XMLB 300 bar - adjustable scale 2 thresholds - 1 C/O Complementary Possible differential minimum at low setting Possible differential minimum at high setting Maximum permissible

More information

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai Last Amended on - Page 1 of 10 I. EMI / EMC TESTS 1. IT Products / Household / Industrial / Medical / Network Telecommunications Equipment Radiated Emission Test (RE) CISPR11:2010 BSEN 55011:2010 CISPR22:2008

More information

K50F003UP cam changeover switch - 3-pole A - screw mounting

K50F003UP cam changeover switch - 3-pole A - screw mounting Characteristics cam changeover switch - 3-pole - 60-50 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

K63F003UP cam changeover switch - 3-pole A - screw mounting

K63F003UP cam changeover switch - 3-pole A - screw mounting Characteristics cam changeover switch - 3-pole - 60-63 A - screw mounting Complementary Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product

More information

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description Capacitive sensor, Foreground Suppression Main features Compact housing Supply voltage: 10 to 30 VDC Output: 100 ma, NPN or PNP preset Make or break switching function LED indication for output and power

More information

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O

XMLB020A2S13 pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O Characteristics pressure switch XMLB 20 bar - adjustable scale 2 thresholds - 1 C/O Main Range of product Product or component type Pressure sensor type Device short name Pressure sensor size Controlled

More information

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector

ILA2D572TC1F0 integrated drive ILA with servo motor V - DeviceNet - indus connector Characteristics integrated drive ILA with servo motor - 24..48 V - DeviceNet - indus connector Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Phase

More information

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD Bulletin Product Selection Open Type and Non-Combination Enclosed (IP, NEMA /) Controllers For use with Line-Connected Motors Rated Voltage [V AC] / Motor Current [A]...... Max. kw, Hz Max. Hp, Hz Control

More information

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements. Datasheet Single- and three-phase switched-mode power supply units NEW The new power supplies offer a wide range of robust solutions for demanding application requirements. C SEMI F47 US Designed for high

More information

H3DS-X - Solid State Two-Wire Timer

H3DS-X - Solid State Two-Wire Timer OMRON Analog Set Multifunction Timers H3DS Series To view data sheets, click on any link below: H3DS - Standard Timer H3DS-F - Twin Timer H3DS-G - Star-Delta Timer H3DS-X - Solid State Two-Wire Timer Multi-function

More information

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW) Product datasheet Characteristics ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/400...440V(45kW) Complementary Assembly style Function available Supply voltage limits Main Range of product

More information

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

ILE1F661PC1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox Characteristics brushless dc motor 24..36 V - CANopen DS301 interface - L = 122 mm - w/o gearbox Main Range of product Product or component type Device short name Motor type Number of motor poles 6 Network

More information

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input) Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai- Ph: + Fax: E-mail: info@intechchennai.com Website: www.intechchennai.com Temperature Controllers ECS CSM_ECS_DS_E Simple Functi ons in

More information

RUC industrial relays of small dimensions

RUC industrial relays of small dimensions RUC 135 with adaptor (V) Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load Min. switching current Max. inrush current Rated current

More information

55 Series - Miniature General Purpose Relays 5-10 A

55 Series - Miniature General Purpose Relays 5-10 A Series - Miniature General Purpose Relays -0 A - Plug-in or P.C.B. versions - AC or DC coils - Lockable test button and mechanical flag indicator as standard on and CO relays types - Sockets and accessories:

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Main Range of product Product or component type Device short name Complementary Control station type Enclosure material Electrical circuit

More information

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit SSR with Failure Detection Function Detects failures in SSRs used for heater temperature control and simultaneously outputs alarm signals. This product supports the safe design of heater control systems,

More information

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox

ILE1F661PB1A0 brushless dc motor V - CANopen DS301 interface - L = 122 mm - w/o gearbox Characteristics brushless dc motor 24..36 V - CANopen DS301 interface - L = 122 mm - w/o gearbox Product availability : Stock - Normally stocked in distribution facility Price* : 840.00 USD Main Range

More information

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010 INSTALLATION INSTRUCTIONS Revision A1 Rapid City, SD, USA, 01/2010 MODELS 201A 201A-9 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580 fax (605) 348-5685 BE SURE POWER

More information

40 Series - Miniature PCB relays A. Features

40 Series - Miniature PCB relays A. Features 1. = 12.4 1. = 12.4 1. = 12.4 40 Series - Miniature PCB relays 8-10 - 16 A Features 40.31 40.1 40.2 1 & 2 Pole relay range 40.31-1 Pole 10 A (3. mm pin pitch) 40.1-1 Pole 10 A ( mm pin pitch) 40.2-2 Pole

More information

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery AC/DC Battery Controller Power Supply TSPC-240UPS Series Compact universal 24 VDC power supply with integrated battery controller module Battery protection for over voltage, deep discharge, short circuit

More information

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12) s www.siemens.com/energy Auxiliary Relay (7PJ) and Trip Relay (7PJ2) Better protection and more efficiency for your power system Answers for infrastructure and cities. Auxiliary Relay and Trip Relay Catalogue

More information

Safety technique. Emergency Stop Module BH 5928, BI 5928

Safety technique. Emergency Stop Module BH 5928, BI 5928 Safety technique Emergency Stop Module BH 5928, BI 5928 with time delay safemaster 0226419 Function diagram According to EU directive for machines 98/37/EG According to IEC/E 60 204, E 954-1 Safety category

More information

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive MAKING MODERN LIVING POSSIBLE Design Guide VLT MCD 100 Soft Starter the single speed drive Contents Contents 1.1.1 Introduction 2 1.2 Technical Data 3 1.3.1 Functional Diagram 4 1.3.4 Wiring 5 1.3.5 Adjustments

More information

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation

More information

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi

CO (DPDT) 16/25 250/ /440 2,000 4, /0.5/ /0.5/ (5/5) 300 (5/5) AgNi 46 Series - Miniature industrial relays 8-16 A Features 46.52 46.61 1 & 2 Pole relay range 46.52-2 Pole 8 A 46.61-1 Pole 16 A Socket mount or direct connection via Faston connectors AC coils & DC coils

More information

Electronic On-Delay Timers TA8-A/TA8-SA

Electronic On-Delay Timers TA8-A/TA8-SA Electronic On-Delay imers A8-A/A8-SA New short body on-delay timers, with 16 ranges selectable from front panel. Plug-in or panel mounting iming ranges 0.05 secs to 60 hours 16 ranges, front panel selectable

More information

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY CONNECTIONS INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION!! FOLLOW NATIONAL, STATE AND LOCAL CODES! READ THESE INSTRUCTIONS

More information

Electronic timers CT-S range Function diagrams

Electronic timers CT-S range Function diagrams CT-S range Function diagrams - X1-Z2 = ON- delay CT-ERS, CT-MBS, CT-MFS t = set delay time / ts = storing time; t = t1 + t2 = OFF-delay CT-AHS, CT-MBS, CT-MFS X1-Z2 t = set delay time / ts = storing time;

More information

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ.

PRODUCT SPECIFICATION OUTPUT CURRENT (A) OUTPUT CURRENT TOLERANCE ±7% ±7% ±10% ±10% ±7% 1.8. Units % % % Typ. Typ. 0-10V Dimmable FEATURES: AC Input 100~277VAC Built-in Active PFC Function Protection: SCP / OVP / OTP 24V Auxiliary Output 0-10V Dimming Control Dimming 1 ~ 100 Flicker Free High Operating Ambient Temp.:

More information

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101428D0201 28/03/11 -.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

Presentation Soft starters 0 Altistart 48 soft start - soft stop units Presentation Soft starters 5 6 7 65_Ver.-EN.fm/ Presentation (continued) Soft starters Applications The Altistart 8 soft start - soft stop unit is a controller with 6 thyristors which is used for the torque-controlled

More information

ILA1F572PB1F0 integrated drive ILA with servo motor V - CANopen - PCB connector

ILA1F572PB1F0 integrated drive ILA with servo motor V - CANopen - PCB connector Characteristics integrated drive ILA with servo motor - 24..36 V - CANopen - PCB connector Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 1860.00 USD Main Range

More information

LR9 F OVERLOAD RELAYS

LR9 F OVERLOAD RELAYS Issued November 2009 DATA SHEET LR9 F OVERLOAD RELAYS Based on Schneider MKTED2050EN Catalogue General 6 Motor protection Operating conditions There are many possible causes of electric motor failure.

More information

ILE1B661PC1A1 brushless dc motor V - Profibus DP interface - L = 174 mm - 18:1

ILE1B661PC1A1 brushless dc motor V - Profibus DP interface - L = 174 mm - 18:1 Characteristics brushless dc motor 24..36 V - Profibus DP interface - L = 174 mm - 18:1 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 1640.00 USD Main Range

More information

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101415D0201 25/03/11 AF30-30-11-.. / AF30Z-30-11-.. 2-stack 3-pole Contactors AC / DC Operated - with Screw Terminals AF30(Z) contactors are used for controlling power circuits

More information

Slim P.C.B. Relays (EMR or SSR) A

Slim P.C.B. Relays (EMR or SSR) A 34 SЕRIES Slim P.C.B. Relays (EMR or SSR) 0.1-0.2-2 - 6 Bottling plant Packaging machines Labelling machines Road / tunnel lighting Burners, boilers and furnaces Timers and lighting controls Electronic

More information

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION! INSTALLATION INSTRUCTIONS FOR SYMCOM S MOTORSAVER MODEL 460 BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

More information

5 mm contact pin pitch PCB or 95 series sockets

5 mm contact pin pitch PCB or 95 series sockets 1. = 12.4 1. = 12.4 44 Series - Miniature PCB relays 6-10 A Features 44.2 44.62 2 Pole relay range 44.2-2 Pole 6 A ( mm pin pitch) 44.62-2 Pole 10 A ( mm pin pitch) PCB mount - direct or via PCB socket

More information

2 pole 10 A PCB mount A1 A

2 pole 10 A PCB mount A1 A Series - Miniature general purpose relays - 0 A Features Printed circuit mount, general purpose, & Pole relays. - Pole 0 A. - Pole 0 A. - Pole A AC coils & DC coils Cadmium Free contacts (preferred version)

More information

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101419D0201 06/04/11-40-00-.. / Z-40-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440

More information

ILE2T661PB1A3 brushless dc motor V - Modbus TCP interface - L = 174 mm - 54:1

ILE2T661PB1A3 brushless dc motor V - Modbus TCP interface - L = 174 mm - 54:1 Characteristics brushless dc motor 24..48 V - Modbus TCP interface - L = 174 mm - 54:1 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 1540.00 USD Main Range of

More information

www.ic-electronic.com Soft starter with integrated Motor Protection, Current and Voltage control Single phase controlled with internal by-pass ated operational Voltage 230VAC Frequency 45... 65Hz Self

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A 55 Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage

Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage 35 Royal Road Flemington, NJ 08822-6000 Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage R ated load Min. switching current Max. inrush current

More information

Safety Standards. Model Number:

Safety Standards. Model Number: Highlights & Features RoHS Compliant Relay alarm indirection Built-in 2 channel DC OK signal Caused by rugged handing Conformal coating on PCBA to protect against chemical and dust pollutants Class I,

More information

Electronic timers CT-E range Selection and ordering details

Electronic timers CT-E range Selection and ordering details Selection and ordering details Characteristics 12 single function and 2 multifunction (24-240VAC/DC) Single or dual supply voltage ranges 24VAC/DC, 110-130VAC, 220-240VAC Output contacts 1c/o contact (250V

More information

Electronic Timer - Series Micon 225 Signal Based Multi - Function

Electronic Timer - Series Micon 225 Signal Based Multi - Function Electronic imer - eries Micon 225 ignal Based Multi - Function Multi-function with ignal tart and upply tart. 16 iming Functions selected by DIP switch. wo independent relay outputs with either both relays

More information

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet SBC042D020 06/04/ -22-00-.. / Z-22-00-.. 4-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 440 V DC.

More information

Test report. Type VRLTC load tap changer VRLTC 1500A Type test summary report

Test report. Type VRLTC load tap changer VRLTC 1500A Type test summary report Test report Type VRLTC load tap changer VRLTC 1500A Type test summary report Date: 10 October 2012 Type Test Summary Report Type VRLTC Vacuum/Reactance Load Tap Changer ABB has tested the Type VRLTC, vacuum

More information

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter. Standard AC SB5W Standard AC Intro duction Induction Reversible Right -Angle Gearheads SB5W AC Speed Control Inverter SB5W US ES2 FE1/FE2 Watertight, Dust-Resistant Torque Accessories Installation A-143

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional

More information

Model Number Structure. Characteristics. Model Number Legend. Soft Starter. Applicable Motors. Accessories

Model Number Structure. Characteristics. Model Number Legend. Soft Starter. Applicable Motors. Accessories Three-phase Hybrid Soft er (Soft, Kick, Current Limit, Soft Stop) CSM DS_E_6_1 Built-in Bypass Relay and Smooth s/stops Achieved in a Compact er Advanced functions include soft start, kick start, and soft

More information

Design Guide. VLT Soft Start Controller MCD 100

Design Guide. VLT Soft Start Controller MCD 100 Design Guide VLT Soft Start Controller MCD 100 Introduction The MCD 100 soft starters are designed for soft starting and stopping of 3 phase a.c. motors, thus reducing the inrush current and eliminating

More information

Solid State Relays, 3-phase

Solid State Relays, 3-phase PMA Prozeß- und Maschinen-Automation GmbH Solid State Relays, 3-phase Zero-Point switching, heatsink integrated Main Characteristics: Three-phase controlled Zero switching LED display Various connection

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

Cat N 3. OVERALL DIMENSIONS

Cat N 3. OVERALL DIMENSIONS Cat N Motor driven remote control module 87045 LIMOGES Cedex - FRANCE Telephone : + 33 5 55 06 87 87 Fax: + 33 5 55 06 88 88 Cat N : : 4 062 91 CONTENTS PAGE 1. Description - Use...1 2. Product range...1

More information

Note1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2)

Note1: tested at nominal Vin, full load and at +25 C ambient. Package (3) CTRL Logic (2) Features Regulated Converters : Wide input voltage range.6kvdc Isolation UL, IEC/EN69 and EN certified Efficiency up to 88% OVP, OCP & OTP + C max. case temperature Description The RPA-AW series are high

More information

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29 87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 CTX 3 Control relays Cat. N (s) : 4 168 00..04/06/09..14/16/19..24/26/29 CONTENTS PAGES 1. Description - Use... 1 2. Range... 1 3.

More information

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals 25 to 55 A culus CE Application AF09... AF38 4-pole contactors are used for controlling power circuits up to 600 V AC and 240 V DC.

More information

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices)

Subrange SmartWire-DT electronic motor starters. Basic function Reversing starters (complete devices) DATASHEET - EMS-RO-T-9-SWD-ADP Reversing starter 9A with SmartWire-DT Part no. EMS-RO-T-9-SWD-ADP Catalog No. 172763 Eaton Catalog No. EMS-RO-T-9-SWD-ADP EL-Nummer 4110026 (Norway) Delivery program Product

More information

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors 90 Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors Environment characteristics Conforming to standards IEC 60947, NF C 63-110, VDE 0660, BS 5424 Product certifications LCp

More information

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h No Filter 81.6 % Auto 9.1 m3/h 250.0 m3/h Auto 99.7 m3/h 100.0 m3/h Auto 91.3 m3/h 92.0 m3/h Auto 40.0 m3/h 7. MW Auto 50.7 m3/h 50.0 m3/h 7.2 % Auto.6 % 45.0 % ABB NF Contactor Relays Overview...3 Ordering

More information

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC101412D0201 25/03/11-30-00-.. / Z-30-00-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220

More information

XACA871 pendant control station XAC-A - 8 pushbuttons

XACA871 pendant control station XAC-A - 8 pushbuttons Characteristics pendant control station XAC-A - 8 pushbuttons Complementary Control station colour Connections - terminals Mechanical durability Cable entry Contact code designation [Ithe] conventional

More information

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi

881WP. Type List. Ordering Information 881 WP1-1A C - - C Basic series designation 4. C -- Contact material AgNi Type List Terminal style WP (High power type, terminals)-.0mm pitch Contact form A (SPNO) Features Low Profile mm w/ fasten terminals. High Rating 7A 277VAC. High temperature withstand up to 2. UL/CUL

More information

Application example of a motor controlled by MCD100 and protected by a circuit breaker

Application example of a motor controlled by MCD100 and protected by a circuit breaker VLT T Soft Start Controller MCD 100 MCD 100 is a cost effective and extremely compact soft starter for AC motors up to 11 kw. Due to a unique semiconductor design MCD 100 is a true fit and forget product.

More information