SICON. Connectors with Stepless Shear-Off Bolts. the power connection THE PFISTERER GROUP
|
|
- Sharleen Wilson
- 5 years ago
- Views:
Transcription
1 SICON Connectors with Stepless Shear-Off Bolts THE PFISTERER GROUP the power connection
2 SICON The Right Connection for All Conductors For years now, bolted clamps, connectors and cable lugs have been gaining ground - with good reason. Bolted connectors offer technical and practical advantages that compression technology cannot match. Simple Installation with Standard Tools SICON bolted connectors are installed directly onto the ends of the conductor with a standard allen key. The innovative design of the stepless shear bolt allows installation regardless of the conductor type. Thanks to the special design of the bolt, optimal contact force is always achieved. Easy to Install All SICON connectors can be easily installed, even under tight spots. The bolt shears off smoothly when it is tightened. The remains stay in the tool and can be safely disposed of. The bolt always shears off at the top edge of the connector body. This way, there are no sharp protrusions. All edges of the connector body are rounded. Cost-Effective Thanks to Versatility Every SICON connector covers a wide -section range. This way, you always have the right connectors with you on site. And even if during repair work it is unclear what type of conductors must be connected and in which condition are they in, SICON is the right choice. SICON connectors are electrically/mechanically type-tested in accordance with IEC class A. Go to Video SICON Customized Etensive product range: SICON provides the right connector for any application. PFISTERER also manufactures SICON shear bolt connectors to meet individual customer requirements. Our eperts will carry out all the necessary consultation, dimensioning, engineering, pilot production, testing and series production. 2 SICON
3 SICON Bolt Prevents Installation Errors The patented SICON bolt was developed without predetermined shear-off points. This means that the full load capacity of the thread is always used, thus ensuring perfect contact pressure. A friction disc on the tip of the bolt ensures that the conductor strands are not damaged. Always the right connector: Large ranges ensure high fleibility at the construction site. Benefits Reliable connection for all conductors Optimal contact force for all conductors No damage to individual strands Installation with standard tools Ideal for all type of joints or termination Wide application range SICON in Numbers Conductor cross-section: mm² Conductor material: aluminum, copper (all common types) All Conductors are Optimally Connected SICON connectors can be used independently of the conductor material, type, voltage level and current. No matter whether aluminum or copper, solid or stranded the conductor is always connected with perfect contact pressure. For aluminum conductors, this means with a contact force up to 30% higher than of conventional connectors. The transverse grooves in the clamping channel break through the oidation layers and reliably establish the contact. Always the right choice: SICON combines all conductor designs and materials safely and reliably. SICON 3
4 Covering Caps Cover up completely the entire bore countersinks Restore a full cylindrical shape No sharp edges - which eliminates possible damages of the joint body. Stepless Shear-Off Bolt No predetermined shear-off points Always full load capacity of the thread No time consuming rework necessary The optimal shear off torque will always be reached automatically. Centering Rings One-click fast installation Centered position of small conductors Minimizes voltage stress at transition from connector body to cable insulation. Short Connector Length Easier centering in the middle of the stress control area Fits into shorter joints, bigger application range. Oil Stop Ensures proper conductor positioning Eliminates oil leakage when connecting oil impregnated conductors Accommodates transition applications from polymeric to oil impregnated conductors. 5 SICON
5 Universal Application Covers a wide cross section range All conductor designs For aluminum and copper conductors Reduces inventory and prevents accidental use of wrong connector. Copper Aluminum Installation with Standard Tools Ratched and appropriate heagonal socket Impact wrench Easy installation. Transverse Grooves Breaks through oidation layers Higher tensile strength Higher cross-line conductivity of stranded conductors, increased current flow from inner to outer strands Ensures low contact resistance and long term reliability. Friction Disc Independet contact force of aluminum and copper conductors Higher contact force No damage of single strands Reliable and good electrical contact. SICON 6
6 SICON Application Range Split Connector This split connector can be used in installations where it is difficult to install the connector on the conductor. The connector comes apart in 2 pieces and allows easy installation. The 2 pieces are then bolted together in the middle to form one connector again. Typical uses are PILC to PILC 3/C joints and any tight spot where it is difficult to bend the cable. Branch Connector The branch connector can be used to join 3 different conductors regardless of size or material. These are typically used when joining two main lines and then running a tap or a branch. These can be used in heat shrink, cold shrink and hand-taped joints 360 Cable Lug PFISTERER SICON bolted cable lugs enable you to connect the cable ends of electrical devices with a bolt or a stud. Standard cable lugs are used in cable terminations for indoor and outdoor applications and can be used in both heat shrink and cold shrink accessories. Centered cable lugs are mainly used in seperable connectors. Cable lugs with 2-hole palms are also available. 4 SICON
7 Product Selection Guide Connector cross-section L OD l H z He Size Part No. (mm²) (mm) (mm) (mm) (mm) (mm) (mm) (Al + Cu) Bolted Connector (MC-OS) sector Standard Cable Lug Cable Lug (MCL) Two Mounting Holes with Mounting Hole Distance 44.5 mm [y] Branch Connector (BMC) / Split Connector (SPLIT-MC) Repair Connector (RMC-OS) Others are available by special request Technical Drawings Branch Connector Standard Cable Lug Cable Lug Bolted Connector l l l l y y H H z z H H z z SICON 7
8 PFISTERER Holding AG Rosenstraße Winterbach Germany Phone: Fa: info@pfisterer.com The PFISTERER Group, which also includes LAPP Insulators, is amongst the world s leading specialist equipment and system suppliers in the energy infrastructure industry. Around 2,700 employees develop, produce and distribute components and complete solutions for the particularly sensitive interfaces in modern energy networks. With a complete range of products and services, the PFISTERER Group provides customised solutions for the complete transmission chain from low and medium to high and ultra-high voltage. Everything from a single source. Worldwide For our customers, that means: the best possible solutions for all their requirements now and in the future. SICON M EN / 2017 PFISTERER Holding AG We accept no liability for printing errors/subject to technical modifications
TENSOREX C+ Spring Automatic Tensioning Device for Railway and Tramway Overhead Contact Lines. the power connection THE PFISTERER GROUP
Spring Automatic Tensioning Device for Railway and Tramway Overhead Contact Lines THE PFISTERER GROUP the power connection Constant Tension from a Compact Design The overhead contact lines of railways
More informationRailway Infrastructure. Competent Solutions for Electric Railways and Tramways. the power connection THE PFISTERER GROUP
Competent Solutions for Electric Railways and Tramways THE PFISTERER GROUP the power connection Solutions for Today s and Future Challenges Reliable and maintenance-free infrastructure provides the basis
More informationMechanical Connectors, Lugs and Repair Sleeves for Medium Voltage Cable Accessories up to 42 kv
Mechanical Connectors, Lugs and Repair Sleeves for Medium Voltage Cable Accessories up to 42 kv Mechanical Connectors, Lugs and Repair Sleeves for Medium Voltage Cable Accessories up to 42 kv Features
More informationNexans Power Accessories. Bolted connectors
Nexans Power Accessories Bolted connectors 1 Summary 1. The function of bolted connectors The function Physical parameters Crimped versus bolted connectors Advantages of bolted connectors 2. Presentation
More informationMECHANICAL SHEAR-BOLT CONNECTORS A Best Fit Solution for Jointing Cable Conductors
MECHANICAL SHEAR-BOLT CONNECTORS A Best Fit Solution for Jointing Cable Conductors INTRODUCTION Cable accessories have many decades of outstanding performance around the world. The technology for jointing
More informationCONNECTORS AND FITTINGS
Industry photo: should be a the same image as larger industry photo. Either a different crop or different angle. Human photo. Can be environmental/ documentaty style or portrait of engineer. Human photo.
More informationHybrid Energy. CrossPower makes the desert green.
Hybrid Energy CrossPower makes the desert green. CrossPower 135 kw-system successfully in service in the Lithuanian Armed Forces since February 2016 Bringing electricity to people to improve their lives
More informationPower cable accessories catalogue
Power cable accessories catalogue Cable Lugs and Connectors Renewables A brighter future Jointing Tech is a specialist electrical distributor supplying a full range of power cable and accessories into
More informationPower cable accessories catalogue
Power cable accessories catalogue Cable Lugs and Connectors Renewables A brighter future Jointing Tech is a specialist electrical distributor supplying a full range of power cable and accessories into
More informationPFISTERER RAIL SYSTEMS. Components and Systems for the Electrification of Railway Lines.
Connectors, Clamps, Compensating Devices, Insulators and Safety Equipment for Electrification of Rail PFISTERER RAIL SYSTEMS Components and Systems for the Electrification of Railway Lines. Welcome to
More informationNexans WINDLINK connection system. Nexans Power Accessories Germany GmbH
Nexans WINDLINK connection system Nexans Power Accessies Germany GmbH Technical instructions and application infmation Reprinting, even partial, only with special allowance. The data given were determined
More informationPRODUCT SHEET. Elastimold advanced connection system (shear bolt)
PRODUCT SHEET Elastimold advanced connection system (shear bolt) 2 Elastimold cable accessories The Elastimold advanced connection system - shear bolt is the latest solution to be incorporated into the
More information3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series
3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series Data Sheet March 2011 Description 3M Cold Shrink 1/C Transition Splice Kits QS-III, 5510A-1T-PILC Series (which includes 5513A-1T-PILC,
More informationTerminations. 3M Cold Shrink Terminations FAX TERMINATIONS. Glossary of Terminations Terms 263 Cable Types for Terminating 264 3M
Terminations Glossary of Terminations Terms 263 Cable Types for Terminating 264 3M Cold Shrink QT-III Silicone Rubber Terminations 265 3M Cold Shrink Termination QT-III 69 kv/72,5 kv 270 3M Cold Shrink
More informationPRODUCT BROCHURE. Elastimold advanced connection system (shear bolt)
PRODUCT BROCHURE Elastimold advanced connection system (shear bolt) 2 ELASTIMOLD ADVANCED CONNECTION SYSTEM (SHEAR BOLT) Elastimold cable accessories The Elastimold advanced connection system shear bolt
More informationMedium Voltage. Joints & Terminations
57 - Cold Shrink Joints Supporting Core Radially shrinkable elastomeric splice Semi-conductive layer High permitivity insulation layer 6.6/11/(12) kv 3M QS1000 is a one-piece cold shrink joint body manufactured
More informationIEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector
www.chardongroup.com IEC Separable Connectors 36 kv and 42 kv, 630A and 1250A Front T-Body / Coupling (Rear) T-Body Connector Application Chardon Front T-Body / Coupling (Rear) T-Body connectors are fully
More information3M Mechanical Shearbolt Connectors, QCI Series
M Mechanical Shearbolt Connectors, QCI Series Data Sheet November 2011 Description Connector Contents M Mechanical Shearbolt Connectors, QCI Series are designed to cover a wide range of conductor sizes
More informationCLICK-FIT. High Voltage Accessories for Extruded Cables
CLICK-FIT High Voltage Accessories for Extruded Cables Linking the future As the worldwide leader in the cable industry, Prysmian Group believes in the effective, efficient and sustainable supply of energy
More informationThrottle Cable Pull - Patent Pending By: NetGain Controls, Inc.
Throttle Cable Pull - Patent Pending By: NetGain Controls, Inc. Powering the future! Installation Guide 2011 All Rights Reserved NetGain Controls, Inc. 1 of 8 Introduction Thank you for purchasing a NetGain
More informationPROSTHETIST MANUAL. MC Triad Preamp Systems. Introduction. Features. Components
PROSTHETIST MANUAL MC Triad Preamp Systems Introduction The Motion Control Triad Preamp System is a versatile preamp/electrode system. It provides four different installation options and interchangeability
More informationER Collets Nuts Disks
Collets Nuts Disks 1 Collets - Features Benefits 2 Concentricity T.I.R. 3 Assembly Instructions 4 8 8-UP 8-MB 5 11 11-UP 11-MB 11-ND 6 16 16-UP 16-MB 7 20 20-UP 8 25 25-UP 9 32 32-UP 10 40 40-UP 12 50
More informationQTII (X) Series Silicone Rubber Cold Shrink Termination Kits
QTII (X) Series Silicone Rubber Cold Shrink Termination Kits For MV Armored/Non-Armored Cables up to 36kV DATA SHEET Update: August 2006 1. Product Description The 3M QTII (X) Series are Silicone Rubber
More information3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination
3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination Instructions IEEE Std. No. 48 Class 1 Termination CAUTION Working around energized electrical systems may
More informationCold Shrink QS T Trifurcating Transition Splice Kit
Cold Shrink QS2012-13-3T Trifurcating Transition Splice Kit Instructions IEEE Std. 404-1993 15 kv Class 110 kv BIL Completed Splice Cable Size Range Requirements PILC 500 kcmil Conductor Size (240 mm 2
More informationFLUID POWER FLUID POWER EQUIPMENT TUTORIAL PIPE WORK. This work covers part of outcome 2 of the Edexcel standard module:
FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PIPE WORK This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed for outcome 2 is
More informationResin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide
1ZSC000563-AAC en, Rev. 2 Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers,
More informationPF Coil Fabrication Overview
PF Coil Fabrication Overview PF Coils Information Meeting Barcelona - 15 th October 2012 This presentation is intended for reference purposes only and is not a legally binding document PF Building Layout
More information3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits
3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits With High-K Stress Relief For 3-Conductor Type G (Ground Wire), Copper Tape Shield, Armored Cables 7600-S-3G Series Instructions IEEE Std.
More informationMetAl. Optimum core drilling with the new FEIN KBB core drilling units and HSS drill bits.
MetAl Optimum core drilling with the new FEIN KBB core drilling units and HSS drill bits. Introduction New application solutions from FEIN. In 1895, FEIN invented the world s first electric hand drill.
More informationGatesFacts Technical Information Library Gates Compass Power Transmission CD-ROM version 1.2 The Gates Rubber Company Denver, Colorado USA
MAKING THE RIGHT SHAFT CONNECTIONS Daniel Schwartz & Gary Porter Power Transmission Design August, 1996 Securing a belt pulley to a drive shaft often seems like such a routine task, that engineers and
More informationpower cable accessories
power cable accessories kv up to 4 kv Completing the picture based on experience is the future nkt cables GmbH NKT was established in 89 as cable manufacturer. In 999 NKT A/S Denmark merged with Felten
More informationCable systems We offer you the essential components for a future-oriented e-mobility.
Range We are working for you worldwide. Cable systems We offer you the essential components for a future-oriented e-mobility. Individual items We start with your ideas, so you can make your vision of intelligent
More informationHYMAX VERSA by Krausz Coupling and Repair Solutions
HYMAX VERSA by Krausz Coupling and Repair Solutions HYMAX VERSA. VERSATILE STAINLESS STEEL COUPLING. Krausz HYMAX VERSA products provide a highly versatile stainless steel coupling solution for connecting
More informationLoadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.
3 Loadbreak Elbows 200 Amp 5-15 kv Industrial pg. 252 Loadbreak Elbows 200 Amp 25 kv Industrial pg. 254 Loadbreak Elbows 200 Amp Industrial pg. 255 Loadbreak Elbows Accessories 3 Loadbreak Elbows 3M 200
More informationWRSS Wraparound Repair Sleeve Installation Instructions
WRSS Wraparound Repair Sleeve Installation Instructions TECP-30-263. Issue 1. 4/2016 1.0 General Product Information This practice provides information regarding the description and use of Raychem s WRSS
More informationLOCKING BUSHES & SHAFT COLLARS
LOCKING BUSHES & SHAFT COLLARS INDEX TAPER BUSHES Page 3 WELD-ON HUBS Page 4 QD BUSHES Page 5 MECHANICAL LOCKING BUSHES CAL1 (Not Self-Centering) Page 6 CAL2 (Not Self-Centering) Page 7 CAL3 (Self-Centering)
More informationBranch Splice QS-2001B
Branch Splice QS-2001B Data Sheet 1. Product Description The 3M Branch Splice QS-2001B molded rubber splice kits are designed to connect extruded dielectric power cables rated 15 kv. The basic kits handle
More informationHigh Voltage Joints and Terminations up to 72,5 kv 145 kv
High Voltage Joints and Terminations up to 72,5 kv 145 kv 3M Cold Shrink Termination Kits QT-III and Joint Kits are designed to provide high reliability and save you time and money. They install quickly
More informationINDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS
INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS TKF TECHNOLOGICAL LEADERSHIP IN CONNECTIVITY SOLUTIONS Since its establishment in 1930 TKF developed from
More information3M Cold Shrink Splice Kits, QS T Series
3M Cold Shrink Splice Kits, QS-2000-3T Series For 15 kv Trifurcating Transition Splice Kits Data Sheet October 2011 Description 3M Cold Shrink Splice Kits, QS-2000-3T Series for 15 kv Trifurcating Transition
More informationDRUM BRAKE RIMS Periodic inspection of drum brake rims is necessary to determine indications of uneven or excessive wear. In general, brake rim failures other that regular wear are caused by brake linings
More informationUnderground Distribution
Aluminum Flood-Seal TM Mechanical Connectors Save outlet space These connectors feature the Sweetheart TM outlet configuration that nests two equal-sized service cables from #6 to 2/0 or two different-sized
More information4. SHIELDS. 4.1 Power Cable. 4.2 Electronic Cable Conductor Shield (Strand Shield) Outer Shield (Insulation Shield) 60
4. SHIELDS 4.1 Power Cable 4.1.1 Conductor Shield (Strand Shield) 60 4.1.2 Outer Shield (Insulation Shield) 60 4.2 Electronic Cable 4.2.1 Foil Shield 62 4.2.2 Copper Braid Shield 63 4.2.3 Spiral (Serve)
More informationTIDALFLUX 2300 F Quick Start
Quick Start Electromagnetic flow sensor for partially filled pipes The documentation is only complete when used in combination with the relevant documentation for the signal converter. KROHNE CONTENTS
More informationYOUR SPECIALIST AROUND CABLE AND WIRE. Catalog
Catalog "upi Cable- And wirestockings, Quality based on tradition The company rupi cologne is your perfect partner for anything in Cable and rope stockings. Since 1966 we have been the market leader in
More informationAccessories. Introduction. Cable Hangers LINE PRODUCTS TRANSMISSION
Accessories Introduction While a number of cable related accessories are available on the market, RFS components are of the highest quality and are designed to provide years of trouble-free service. Together
More informationIEC Separable Connectors 17.5 kv/24 kv, 630A
IEC Separable Connectors 17.5 kv/24 kv, 630A Front T-Body / Coupling (Rear) T-Body Connector Application The Chardon T-Body connectors are used to terminate polymeric cable to dead front apparatus such
More informationTransformer Bushing Type EKTO
Transformer Bushing Type EKTO Mounting Operating and Maintenance Instructions Operating Instructions BAL EKTO/04e Visum 01/14 T/gue Page 1 of 16 SAFETY INSTRUCTIONS These instructions are valid for mounting,
More informationsa B-CABLES nv PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water sa B-CABLES nv ENERGY
PROTOLON(ST) NTSCGEWOEU Medium Voltage Flexible Cables for Use In Water ENERGY Technical Data Electrical Thermal Type Type designation PROTOLON(ST) NTSCGEWÖU Approvals/ standards DIN VDE 0250 part 813
More informationTransformer Bushing Type EKTG
Transformer Bushing Type EKTG Mounting Operating and Maintenance Instructions Operation Instructions BAL EKTG/05e Visum 01/14 T/gue Page 1 of 18 SAFETY INSTRUCTIONS These instructions are valid for mounting,
More informationService Instruction Front Suspension PASHLEY-MOULTON. 1.0 General Description. 2.0 Adjustment
Service Instruction Front Suspension PASHLEY-MOULTON 1 General Description 2 Adjustment 3 Problems and their Remedies 3.1 Clunking or Banging Noises 3.2 Suspension Squeaking 3.3 Seized Suspension 4 Disassembly
More information(K),(M),(P)489TB/G Up to 42 kv
IS91374-ENG - 489TB/G-45/S 22 October 2012 - Revision 1 - Supersedes edition of 4 May 2012 Page 1 of 9 CAUTION : Read instructions thoroughly and completely prior to beginning installation. Installation
More information3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable
3M Cold Shrink 3-Conductor Inline Splice Kits QS-III 5786A- MT, 5787A-MT and 5788A-MT 25/28 kv for use with Armored and Non- Armored 3/C Cable Data Sheet September 2010 Description 3M Cold Shrink 3-Conductor
More information1 Product Description System Layout Safety Instructions Intended Use Installation... 3
Order Number 0812xx- Contents 1 Product Description... 2 2 System Layout... 2 3 Safety Instructions... 3 4 Intended Use... 3 5 Installation... 3 5.1 Hanger Clamp... 3 5.2 Cutting of Conductor Rail... 4
More informationINSTALLATION INSTRUCTION PEM1093ENG ENGLISH
INSTALLATION INSTRUCTION PEM1093ENG 2017-04 ENGLISH HEAT SHRINK TERMINATIONS FOR SINGLE CORE CABLES INDOOR TERMINATIONS HIT1.12, HIT1.24 AND HIT1.36 OUTDOOR TERMINATIONS HOT1.12, HOT1.24 AND HOT1.36 2/12
More informationweb:
web: CONTENTS INTRODUCTION 00 CU LUGS 00 TERMINALS 00 HEAT SHRINKABLES 00 CABLE TIES 00 CABLE MARKERS 00 GLANDS 00 CLEATS 00 PVC TAPES 00 INTRODUCTION Aftec Electrical Solutions Aftec international with
More information(K),(M)430TB/G Up to 36 kv
IS90722-ENG - 430TB/G-45 25 June 2009 - Revision 8A - Supersedes edition of 25 November 2008 Page 1 of 10 CAUTION : Read instructions thoroughly and completely prior to beginning installation. Installation
More informationPower cable accessories catalogue
Power cable accessories catalogue MV Terminations & MV Joints Excellence in Training Obtain an accreditation in a wide range of joints and terminations. Courses available in low voltage, medium voltage
More informationCABLE SYSTEMS. Accessories and Systems for Medium and High-Voltage Cables up to 300 kv.
MV-CONNEX, HV-CONNEX, IXOSIL Terminations, IXOSIL MSA Slip-on Joint Boxes CABLE SYSTEMS Accessories and Systems for Medium and High-Voltage Cables up to 300 kv. Welcome to the CABLE SYSTEMS Centre of Competence.
More informationHigh Voltage Accessories up to 72.5 kv
High Voltage Accessories up to 72.5 kv Technical instructions and application information The data given were determined diligently, but do not release our customers of the duty to carry out tests themselves
More informationDesign specifications
Design specifications Design To relevant standards: IEC, VDE, DIN, ISO, EN With squirrel-cage or slipring rotor Degree of protection IP 55 / IP 65 Cooling method IC511, suitable for both indoor and outdoor
More information600 A 35 kv class deadbreak accessories, tools, and replacement parts
Deadbreak Connectors Catalog Data CA650006EN Supersedes 600-66 July 2014 COOPER POWER SERIES 600 A 35 kv class deadbreak accessories, tools, and replacement parts General Eaton's Cooper Power series 600
More informationMedium voltage - Cable accessories up to 36 kv. Tapes Connection technique Tools
Medium voltage - Cable accessories up to 36 kv Tapes Connection technique Tools TABLE OF CONTENTS General information... 6 7 CAST RESIN-TECHNIQUE...8 11 Straight-through joints for polymeric-insulated
More informationJoined Forces Extensive product portfolio and technologies. Cable Accessories from 1 kv to 550 kv. nkt.com
Joined Forces Extensive product portfolio and technologies Cable Accessories from kv to 550 kv nkt.com NKT manufacturing and testing equipment ensures high quality products. Concentrated Competence With
More informationMINING ROPES.
MINING ROPES www.diepa.de QUALITY MADE IN GERMANY TABLE OF CONTENTS DIEPA Mining Ropes 4 Rope Selection 6 DIEPA MX-series 8 DIEPA ML-series 10 DIEPA MB-series 12 Rope terminations 14 DIEPA MINING ROPES
More informationCATALOG. Sta-Kon Power, connection & control Wire termination & insulation
CTLOG Sta-Kon Power, connection & control Wire termination & insulation Thomas & etts is now Installation Products, but our long legacy of quality products and innovation remains the same. From connectors
More information114 NOSE SEIKO CO.,LTD NOSE SEIKO CO.,LTD
114 NOSE SEIKO CO.,LTD NOSE SEIKO CO.,LTD 115 and Part Code Applicable axis diameter Feature Part Code 5 ~ 3 General purpose cam follower with screwdriver groove on the stud head. Available with stainless
More information1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide
1ZSC563-AAA EN, REV. 7 Transformer bushings type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More information1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide
1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical
More informationInstallation Instructions for Lifeline MC: Cable Splice Using Ceramic Standoffs Technical Information Sheet #402
Installation Instructions for Lifeline MC: Cable Splice Using Ceramic Standoffs Technical Information Sheet #402 Classified by Underwriters Laboratories to UL 2196 for one hour installations For use with
More informationComparison Chart. extremely difficult. Finally, separated components can rarely be re-used.
JAN 2014 Traditional Connections Why Go Keyless Keyed Bushing Systems Both QD and Taper-Lock bushing and weld-on hub systems are popular component mounting technologies. Yet both are ultimately keyed connections
More informationPower & Control Cable IEC
(2-, 3-, and 4-cores) U 0 PVC-Insulation, Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14).
More informationJOSLYN. Underground Cable Accessories. Table of Contents. JPT/JIPT Polymer Terminations. ShrinkTite Sealing Kits. Easy-On II Terminations
Underground Cable Accessories JOSLYN Table of Contents JPT/JIPT Polymer Terminations 15kV, 25kV & 35kV ShrinkTite Sealing Kits 1kV In-Line Splice Sealing Kit Cable Jacket Sealing Kit Easy-On II Terminations
More information2. Hydraulic Valves, Actuators and Accessories. 24 Marks
2. Hydraulic Valves, Actuators and Accessories 24 Marks Co related to chapter 602.2 Describe working principle of various components used in hydraulic & pneumatic systems. 602.3 Choose valves, actuators
More informationMedium Voltage Catalogue 2013
Medium Voltage Catalogue 2013 D813 SAP.Nr. 198693 1112 Medium Voltage 2013 Data, values and illustrations given in this documentation are correct and reliable according to the current state of our knowledge.
More informationProduct Catalog. Fittings ½ AIR PIPE FITTINGS Fitting, 1/2 Air Pipe End Cap Coupler, with Tank Valve
To complement our extensive line of cable pressurization products, System Studies also sells a variety of air pipe and pressure tube fittings. This section of the catalog describes these commonly used
More information1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide
1ZSE 2750-106 EN, REV. 7 Oil SF 6 bushings type GOEK Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationREPAMAX. Versatile Stainless Steel Coupling. Versatile Stainless Steel. By Krausz Wide-Range Couplings. Joins as a coupling. Repairs as a clamp.
JOIN REPAIR RESTRAIN REPAMAX Versatile Stainless Steel By Krausz Wide-Range Couplings Joins as a coupling. Repairs as a clamp. Versatile Stainless Steel Coupling REPAMAX Product Information Versatile Stainless
More informationAssembly Manual. 1/10th Formula 1 Car
Assembly Manual 1/10th Formula 1 Car Center Pivot Bag 1 3374 - Center Pivot Socket 40194 - Hard Anodized Alum Pivot ball 3254-2-56 *Note - Sometimes it is helpful to slightly over-tighten the top clamp
More informationHeat-Shrink Indoor and Outdoor Termination SKSE
Heat-Shrink and Termination SKSE For Polymer-Insulated and Paper-Insulated Power Cables ) = 0.6 / 1 (1.2) kv The conductors of the cables are connected to longitudinally sealed compression lugs or terminal
More informationEnergy Chain Systems Triflex R Energy Tubes
Energy Chain Systems Triflex R Energy Tubes Multi-Dimensional Movement Energy Chains For Robotic Applications Triflex R Triflex R Series A modular, multi-axis, energy-supply protection system Triflex R:
More information00000 Series Clevis Pin Slotted Hexagon Hex Key Recommended Corresponding Part No. Part No. Size Torque Preload SLT* SLT* HEX
00000 Series Clevis Pin All clevis pins are manufactured from heat treated 416 stainless steel to provide superior strength and wear. Hardness is between 37-40 Rc. The DCD Clevis Pin is a shouldered type
More information3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series
3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series For 3-Conductor Copper Tape Shield Cables without Ground Wires Instructions IEEE Std. No. 48 Class 1 Termination CAUTION Working
More informationInstallation Instruction Heatshrink Termination For 3 Core Polymeric Cables 7.2kV to 36kV
Installation Instruction Heatshrink Termination For 3 Core Polymeric Cables 7.2kV to 36kV * PLEASE READ INSTRUCTIONS THOROUGHLY BEFORE PROCEEDING * INDOOR OUTDOOR Download free QR code scanning software
More informationThe H-MAC Heavy Metal Articulating Chassis Construction Guide
The H-MAC Heavy Metal Articulating Chassis Construction Guide The Heavy Metal Chassis is constructed with two identical drive modules built using 10 mechanical sub-assemblies. The drive modules are integrated
More informationOur tyres for summer and winter. Gislaved. A brand of Continental.
Our tyres for summer and winter Gislaved. A brand of Continental. 2 Nordic know-how Gislaved stands for 110 years of experience with a focus on tyres for difficult road conditions. Its Swedish heritage
More informationINSTALLATION INSTRUCTIONS COOLANT TANK KIT
INSTALLATION INSTRUCTIONS COOLANT TANK KIT 2017+ Honda Civic Type-R Document: 19-0197 Support: info@radiumauto.com NOTES: Installation to be performed on engines that are completely cooled down. Do NOT
More informationTE S RAYCHEM RSTI-CC-58 SCREENED, SEPARABLE COUPLING SYSTEM
Industry photo: should be a the same image as larger industry photo. Either a different crop or different angle. industry photo. This image and the one above should be different versions of the same photo
More informationMedium Voltage (MV) Accessories Catalog
Medium Voltage (MV) Accessories Catalog LINKING ACCESSORIES TO CABLE SOLUTIONS Linking power grids to sustainability TERMS AND CONDITIONS Prysmian shall have the right at any time prior to delivery or
More information3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW)
3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW) for Tape Over Wire and Wire Over Tape Shielded Cable Instructions Class 1 Termination IEC 60840 72,5 kv 69 kv Class 325
More informationWelcome to INTERTECH
Welcome to INTERTECH Intertech Engineering designs, supplies and installs cable accessories for power transmission and distribution. Our wide range of products is suitable for applications from 6.6kV to
More informationCold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit
Cold Shrink QS2013-3T-WS Trifurcating Transition Splice Kit Instructions for Shielded and Belted PILC Cable IEEE Std. 404-1993 15 kv Class 110 kv BIL Completed Splice UniShield Wire Shielded Longitudinally
More informationJabiru J170/230/430/250/450 Constructors Manual. Pre-Paint>Fuselage>Undercarriage>Assemble main gear
Objectives of this task: In this task you will assemble the main undercarriage legs, which includes fitting the axles, disc brakes and wheels and adjusting the brakes. Materials required: Cards # J8 Dual
More informationPower & Control Cable IEC
(2-, 3-, 4,- and 5-cores) U 0 Application For electricity supply and control in public networks and industrial plants; suitable for use in zone 1 and zone 2 group ΙΙ classified areas (IEC 60079-14). Recoended
More informationCold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions
Cold Shrink - Silicone Rubber QTII(X)4S-32H Series Cable Termination Instructions Class I Indoor Termination Voltage Designation: 12/20(24) kv Kit Contents: 1 HeatShrinkBreakoutBootAssembly 3 HeatShrinkBindingSleeves
More information1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide
1ZSE 2750-112 EN, REV. 4 Wall bushings type GSA-AA Technical guide Original instruction The information provided in this document is intended to be general and does not cover all possible applications.
More informationCYLINDER HEAD ASSY (1MZ FE)
OVERHAUL 1. REMOVE W/HEAD STRAIGHT SCREW PLUG NO.1 14209 1405K01 Using a 14 mm straight hexagon wrench, remove the screw plug. 2. REMOVE W/HEAD STRAIGHT SCREW PLUG NO.2 Using a 14 mm straight hexagon wrench,
More informationCompressed Air and Electric Supply System Program C40
Compressed Air and Electric Supply System Program C40 Table of Contents Overview 4 Product Description...4 System Overview....4 Rail Components 5 General Information...5 Load Diagram....5 Rail Couplers....6
More informationPROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation
PROTOLON (SB) PROTOLON (SB) with Copper Core Shield Flexible Cables for Trailing Operation 2 17 BUIS_003.tif 2 18 BUIS_004.tif Selection and dimensioning criteria Refer to Section 4 for further details