CPO Commerce, LLC 60 Crestridge DR Suwanee, GA Customer service#:

Size: px
Start display at page:

Download "CPO Commerce, LLC 60 Crestridge DR Suwanee, GA Customer service#:"

Transcription

1 Model: 2200I Inverter Generator OPERATOR S MANUAL CPO Commerce, LLC 60 Crestridge DR Suwanee, GA Customer service#: customerservice@cpocommerce.com SAVE THIS MANUAL FOR FUTURE REFERENCE This manual contains important information regarding safety, operation, and maintenance.

2 TABLE OF CONTENTS Introduction...3 Parts Ordering / Customer Service...3 Safety Rules...4 Safety Symbols...4 Safety Instructions...4 Features...7 Control Panel Functions...8 ON/OFF Start Switch and Choke...8 Indicator Lights...8 DC Protector...9 Engine Smart Control (EMS)...9 Parallel Outlets...9 Fuel Cap Air Vent...10 Ground Terminal...10 Assembly...11 Connecting Generator to an Electrical System...11 Adding Fuel...11 Adding / Checking Oil...12 Operation...13 Grounding the Generator...13 How to Start Engine...13 How to Stop Engine...14 Attaching Electronic Devices...14 Charging a 12 Volt Battery...15 AC Parallel Operation...16 Don t Overload Generator...17 Wattage Reference Guide...17 Maintenance...18 Maintenance Schedule...18 Checking Spark Plug...19 Changing Oil...20 How to Clean Air Filter...21 How to Clean Fuel Filter...22 How to Store...22 Troubleshooting...24 Diagrams Wiring Diagram

3 INTRODUCTION Thank you for purchasing this superior quality portable generator. When operating and maintaining this product as instructed in this manual, your generator will give you many years of reliable service.. It is designed to supply electrical power to operate tools, appliances, camping equipment, lighting, or serve as a back up power source during power outages. AC Output DC Output Engine Rated AC Voltage Rated Frequency Rated Output Maximum Output USB Outlet Cigarette Outlet Displacement Engine Type Engine Oil Type Engine Oil Capacity Fuel Tank Capacity 120V 60Hz 1700W 2200W 5V DC 1.5A 12V DC 8A 80cc Single cylinder, 4 Stroke, OHV, Air Cooled SAE 10W30 350ml / 11.8oz 4.5L / 1.18Gal Emissions The United States Environmental Protection Agency (US EPA) (and California Air Resources Board (CARB), for engines/equipment certified to California standards) requires that this engine/equipment complies with exhaust and evaporative emissions stan-dards. Locate the emissions compliance decal on the engine to determine applicable stan-dards. For emissions warranty information, please reference the included emissions war-ranty. It is important to follow the maintenance specifications in the manual to ensure that the engine complies with the applicable emissions standards for the duration of the product s life. 3

4 SAFETY RULES Safety Symbols CAUTION! Indicates a potentially hazardous situation which could result in serious injury or death if not avoided. Indicates a potentially hazardous situation which could result in damage to equipment or property. Toxic Fumes Risk of explosion Risk of electric shock Hot surface Safety Instructions the user must understand and follow all manual instructions and use common sense. Read and understand this manual in its entirety before operating this generator. Improper use of this generator could result in serious injury or death. monoxide gas from dissipating. Using a generator indoors WILL KILL YOU IN MINUTES! Carbon monoxide gas is a poisonous, odorless gas that can cause headache, confusion, fatigue, nausea, fainting, sickness, seizures, or death. If you start to experience any of these symptoms, IMMEDIATELY get fresh air and seek medical attention. Install a battery operated carbon monoxide alarm near bedrooms. When working in areas where vapors could be inhaled, use a respirator mask according to all of its instructions. Engine exhaust contains chemicals that lead to cancer and cause birth defects. Always wash hands after handling generator. 4

5 SAFETY RULES Never exceed generators wattage / amperage capacity. This could damage the generator and / or connected electrical devices. Check operating voltage and frequency requirements of all electrical devices prior to plugging them into the generator. Never start or stop engine with electrical devices plugged in to the receptacles. Failure to do so could damage the generator and / or connected electrical devices. Always start the engine and let it stabilize before connecting any electronic devices. Disconnect all electronic devices before stopping the engine. Starter and other moving parts can catch on clothing, jewelry, and hair. Do not wear loose clothing or gloves. Remove jewelry or anything else that could be caught in moving parts. Tie back or wear protective head covering to contain long hair. death. on the unit before starting the engine. Never smoke while operating or fueling this unit. Generator should have at least 5 feet of clearance from buildings or other equipment during operation. When adding or draining fuel, unit should be turned off for at least 2 minutes to cool before removing fuel cap. If unit has been running then the fuel cap is under pressure, remove slowly. To keep fuel from spilling, secure unit so it cannot tip while operating or transporting. When transporting unit, disconnect the spark plug wire and make sure the fuel tank is empty with the 3 in 1 switch is turned to the off position. Pull cord recoils rapidly and pulls arm towards engine faster than you can let go which could result in injury. To avoid recoil, pull starter cord slowly until resistance is felt, then pull rapidly. Avoid contacting hot areas of this unit. Allow hot components to cool before touching. 5

6 SAFETY RULES This generator produces a very high voltage which could result in burn or electrocution causing serious injury or death. Never handle the generator, electronic devices, or any cord while standing in water, while barefoot, or when hands or feet are wet. Always keep the generator dry. Never operate generator in rain or under wet conditions. Use a ground fault circuit interrupter (GFCI) in a damp or highly conductive area, such as metal decking or steel work. Never plug electronic devices into generator having frayed, worn, or bare wires. Never touch bare wires or make contact with receptacles. generator at all times. If using the generator for back up power, notify the utility company. install a transfer switch. Failure to isolate the generator from the power utility could result in serious injury or death to electric utility workers. Generator must be properly grounded to prevent electrocution. Only operate generator on a level surface. Always connect the nut and ground terminal on the frame to an appropriate ground source. Never modify this unit in any way or modify governed speed. Increasing governing speed is dangerous which can result in personal injury and / or damaged equipment. Decreasing governing speed adds an excessive load and can damage equipment. Only when operating at the preset governing speed will this generator supply the correct rated frequency and voltage. Only use this unit as it is intended or serious injury or death could result. Do not bypass any safety device. Moving parts are covered with guards. Make sure all protective covers are in place. Never transport or make adjustments to this unit while it is running. Never insert objects through cooling slots. Never operate this unit if there are any broken or missing parts and only use our Improper treatment of generator can damage the unit and shorten its life. service center. PROP 65 WARNING: This product contains chemicals known to the state of California to cause cancer and birth defects or other reproductive harm. 6

7 FEATURES A B E F G C H D I S O N P Q A - Spark Plug Cover B - Spark Arrestor D - Outer Casing (Side Panel) E - Handle (Grip) F - Air Vent G - Fuel Cap H - Recoil Starter I - Control Panel J - Oil Warning Light K - Overload Indicator Light L - AC Pilot Light M - 3 in 1 Start Switch (RUN / OFF and Choke) N - Economy Switch O - USB Outlet 5VDC 1.5A P - AC Outlet 7 Q - Parallel Outlets R - Ground Terminal S - 12V DC Port

8 CONTROL PANEL FUNCTIONS ON/OFF Start Switch and Choke Start Switch OFF When the Start Switch is in the OFF position the fuel valve is switched off and the engine will not run. Start Switch CHOKE When the Start Switch is in the CHOKE position the fuel valve is switched on and the engine can be started. Start Switch ON When the Start Switch is in the ON position the fuel valve is switched on and the engine can run., Note: The Choke is not required to start a warm engine Oil Warning Indicator Light When the oil falls below the minimum level, the oil warning indicator light comes on and the engine stops automatically. The engine will not Note: If the oil warning indicator light does not come on and the engine stalls, turn the Start Switch to ON and pull the recoil starter. Engine Overload Indicator Light, If the engine overload indicator light comes on, the generator s wattage / amperage capacity has been exceeded by connected electrical devices or by a power surge. When this occurs, the green AC Pilot Indicator Light will go off. The engine will continue to run, but the red Engine Overload Indicator Light will stay on and power will no longer be supplied to connected electronic devices. Oil Warning Indicator Overload Indicator AC Pilot Indicator How to Correct 1. Disconnect any electronic devices then stop the engine. 2. Reduce the total wattage of connected electronic devices until it is within the generator s rated output. 3. Inspect the Air Inlet and Control Panel for any blockage. Remove blockage if found. 4. Restart Engine. Note: The engine overload indicator light may turn on for a few seconds when attaching a load due to a power surge. This is normal. Oil Warning Indicator Overload Indicator AC Pilot Indicator 8

9 CONTROL PANEL FUNCTIONS AC Pilot Indicator Light The green AC Pilot Indicator Light comes on when the engine starts and generates power. Oil Warning Indicator Overload Indicator AC Pilot Indicator DC Circuit Breaker When the DC Circuit Breaker is in the ON position, the generator is able to supply power to connected electronic devices. When the DC Circuit Breaker is in the OFF position, the generator will no longer supply power. The DC Circuit Breaker automatically turns OFF when connecting electronic devices to the generator that exceed the generator s rated output. If the DC Circuit Breaker turns off, reduce the load of connected electronic devices until the load is within the specified rated output. To re-establish power, return the DC Circuit Breaker back to the ON position. CAUTION! If the DC Circuit Breaker turns off again, stop using the generator immediately and consult our dealers. Engine ECO Control When the Engine ECO switch is turned to the ON position, the economy control unit automatically determines the generator s proper engine speed based on the connected electronic load. This results in superior fuel economy and reduces noise. When the ECO switch is turned to the OFF position, the engine runs at the rated speed of 4,850 r/min. Note: The ECO switch must be turned to the OFF position when using electronic devices that require a large starting current, such as a compressor. Parallel Outlets Located just above the Ground Terminal, the generator s Parallel Outlets enable a user to run two D2200iS generator s simultaneously. This operation requires special cables. When operating parallel generators, the rated output is 3.4kVA and the rated current is 28A/120V. For cables and instructions consult a dealer for a PARALLEL OPERATION CABLE KIT. Never connect generators that are different models. Only connect this generator to another D2200iS Standard Generator or D2200iS Companion Generator Only use brands approved parallel operation cable kit to connect generators 9

10 CONTROL PANEL FUNCTIONS Fuel Cap Turn counterclockwise to remove the fuel cap Fuel Cap Air Vent The fuel cap is equipped with an air vent to stop fuel from flowing to the carburetor. The Air Vent must be in the ON position to allow fuel to flow so that the engine can run. Turn the Air Vent to the OFF position to stop fuel flow. ON OFF Ground Terminal The generator s ground terminal must always be used to connect the generator to a driven ground rod. Connect the ground terminal to the driven ground rod with a No 8 AWG (American Wire Gage) copper wire. The wire connects to the terminal between the lock washer and nut. Tighten the nut securely to ensure good connection. Grounding the generator protects you from electric shock that results from a build up of static electricity or undetected ground faults. Generator must be properly grounded to prevent electrocution. Only operate generator on a level surface. Always connect the nut and ground terminal on the frame to an appropriate ground source. 10

11 ASSEMBLY Connecting Generator to an Electrical System If connecting generator to a building s electrical system for standby power, The power from the generator must be isolated from the circuit breaker or alternative power source. The connection must comply with all electrical codes and applicable laws. UNPLUG Never directly connect generator to a household power source. This generator produces a very high voltage which could result in burn or electrocution causing serious injury or death. Never handle the generator, electronic devices, or any cord while standing in water, while barefoot, or when hands or feet are wet. Always keep the generator dry. Never operate generator in rain or under wet conditions. Use a ground fault circuit interrupter (GFCI) in a damp or highly conductive area, such as metal decking or steel work. Never plug electronic devices into generator having frayed, worn, or bare wires. Never touch bare wires or make contact with receptacles. generator at all times. If using the generator for back up power, notify the utility company. install a transfer switch. Failure to isolate the generator from the power utility could result in serious injury or death to electric utility workers. Adding Fuel Set generator on a clean and level surface in an area that is well ventilated. Remove fuel cap. Insert a funnel into the fuel tank and carefully pour gasoline into the tank until fuel level reaches about 1 ½ inches below the top of the neck. Be careful not to overfill the tank to provide space for fuel expansion. Replace fuel cap and secure tightly. ON OFF Turn cap counterclockwise to remove. Do not smoke when adding fuel. provide space for fuel expansion. 11

12 ASSEMBLY Place generator on a level surface. Remove screws and then remove the outer casing cover.(you must remove the spark plug cover to push the side panel off from the inside). Remove the crankcase dipstick. Insert a funnel into the crankcase dipstick hole and carefully add the specified amount of 4-Cycle engine oil (SAE 10W- 30) to empty reservoir until or oil reaches the outer edge of the oil fill hole (crankcase dipstick hole). Be sure to replace dipstick and securely tighten before attempting to start the engine. To check oil, set generator on a level surface, wipe dipstick clean, then reinsert dipstick without re-threading. Recommended Oil: SAE 10W-30 Oil Capacity: 0.35L (11.8oz) CAUTION! generator. Always check oil level before each operation. 12

13 OPERATION Grounding the Generator To avoid electrocution, this generator must be properly grounded prior to use. For instructions see Control Panel Functions pg. 10. Standard Atmospheric Conditions Ambient Temperature: 77ºF (25ºC) Barometric Pressure: 100kPa Relative Humidity: 30% Generator output will vary due to changes in temperature, altitude, and humidity. If the temperature, humidity, or altitude are higher than standard atmospheric conditions, the generator s output will be reduced. The load attached to the generator must therefore be reduced. How to Start Engine Place generator on a level surface. All electrical loads MUST be disconnected from generator. Turn the ECO switch to OFF Turn the Air Vent to the ON position. Turn the 3 in 1 Start Switch to CHOKE Pull recoil handle (starter cord) slowly until resistance is felt, then pull rapidly. Let engine run for several seconds and then gradually, as engine warms up, turn the 3 in 1 Start Switch to the ON position. OFF OFF ON ON Pull cord recoils rapidly and pulls arm towards engine faster than you can let go which could result in injury. To avoid recoil, pull starter cord slowly until resistance is felt, then pull rapidly. Note: To start the generator with the ECO switch in the ON position Disconnect all electrical loads from generator. If ambient temperature is below 32ºF (0ºC) allow 3 minutes for the engine to warm up. The ECO is in ON position, the unit returns to normal operation after the above warm up time. ECO switch must be turned to the OFF position when using electronic devices that require a large starting current, such as a compressor. 13

14 OPERATION How to Stop Engine Turn the ECO switch to the OFF position. Disconnect any electronic device. All loads MUST be disconnect from the generator. Never start or stop the engine with electrical devices plugged in to the receptacles. Turn the 3 in 1 Start Switch to the OFF position. Turn the Air Vent to the OFF position. OFF ON ON OFF Never start or stop engine with electrical devices plugged in to the receptacles. Failure to do so could damage the generator and / or connected electrical devices. Always start the engine and let it stabilize before connecting any electronic devices. Disconnect all electronic devices before stopping the engine. How to Attach Electronic Devices 1. Before Starting generator Make sure the generator is grounded (see page 10 for instructions). Make sure the attached load is within the generator rated output and the receptacle s rated current. Make sure all electrical cords and receptacles are in good condition. Make sure all electronic devices are turned OFF before plugging them into the generator. 2. Start engine 3. If the attached load is small, turn the ECO switch to the ON position. For a larger load, or if attaching multiple electronic devices turn the ECO switch to the OFF position. 4. Make sure the green AC pilot indicator light is on.. 6. Allow generator output to stabilize (engine and attached devices run evenly) before plugging in the next load. 14

15 OPERATION Charging a 12 Volt Battery This generator can be used to charge a 12 volt automotive or storage battery by taking the following steps: ONLY level is low. Never add tap water. 1. Use a wire brush to clean battery terminals if corroded. 2. Before connecting battery to generator, start generator engine. Make sure the DC Protector is turned to the ON position. 3. Securely connect the red cable clamp to the positive (+) battery terminal. 4. Securely connect the black cable clamp to the negative (-) battery terminal. 5. Turn the ESC switch to the OFF position to start battery charging. 6. and 1.28 when measured by a hydrometer. Note: It is strongly recommended to check the gravity level of the electrode at least once per hour with a hydrometer to prevent overcharging and to test the battery s condition. Be careful to follow the hydrometer manufacture s instruction. Battery electrolyte is poisonous and dangerous. Do not disconnect battery clamps while charging. Batteries produce explosive gasses. Disconnecting the battery clamps while charging could spark and ignite. Do not charge battery in an enclosed area. Never smoke while charging the battery or operating or fueling this generator. Battery electrolyte contains sulfuric acid. Avoid contact with skin, eyes, and clothing. Always wear eye protection when charging battery. get immediate medical attention. For internal ingestion, drink large quantities of water or milk, followed by milk of magnesia, beaten egg, or vegetable oil. Contact a medical physician immediately. 15

16 OPERATION AC Parallel Operation The 2200I generator has two models that are compatible with each other (Standard and Companion). It is possible to connect two 2200I generators to each other, using a parallel cable kit. Connect PARALLEL OPERATION CABLES to two 2200I generators according to the instructions provided with the cable kit. Make sure the ECO switch is in the same position on both generators. All electronic devices should be turned OFF and disconnected from generators prior to starting generator engines. Start generator engines. Make sure the green output indicator light comes on for each generator. Allow generator output to stabilize (engine and attached devices run evenly) before plugging in the next load. Parallel Box Maximum Power in Parallel Operation: 4.4kVA Rated Power in Parallel Operation: 3.4kVA For continuous operation, do not exceed the rated output. Note: It is strongly recommended to plug in devices with the overloading the generator. Note: Most electronic devices require power beyond its rated wattage to start. This additional power is referred to as surge watts and usually lasts between 2-3 seconds. When an electronic device is started, the red overload indicator may come on. This is normal. If the light stays on disconnect all electronic devices and stop the engine. Refer to Engine Overload Indicator Light on page 8. Only connect electronic devices to the generator that are in good working order and do not exceed the rated power supply of the parallel generators or the desired receptacle. A faulty appliance or power cord can create an electric shock. Do not use electronic devices that have a damaged cord or plug. If an appliance begins to operate abnormally, becomes sluggish, or stalls, turn off and disconnect appliance immediately. The appliance may have a fault or its rated load capacity exceeds the power supply of the generator. To avoid damage to generator or electronic device, do not connect a load to the generator if its electrical rating exceeds that of the receptacle. Never connect generators that are different models. Only connect this generator to another 2200I Generator or 2200I Companion Generator Only use brands approved parallel operation cable kit to connect generators. The parallel cable must be removed if operating only one generator. Never disconnect or remove the parallel operation cable while generator is still running. 16

17 OPERATION Don t Overload Generator Make sure you can supply enough rated watts for all electronic devices connected to the generator. Rated watts refer to the power a generator must supply to keep a device running. Surge watts refer to the power a generator must supply to start an electronic device. This power surge for starting a device usually lasts between 2-3 seconds but this additional output must be taken into account when selecting the electronic devices you plan to attach to the generator. To prevent overloading the generator take the following steps: 1. Add up the total rated wattage of all electronic devices that will be connected to the generator simultaneously. 2. Estimate surge watts by adding the item(s) with the highest output (it is unnecessary to calculate the surge output for all devices as they should be connected one at a time). 3. Add the Surge Watts to the total Rated Watts in step 1. Keep total load within generator s power capacity. Wattage Reference Guide (Wattages listed are just approximations. Check electronic device for actual wattage) Essentials Rated Watts Surge Watts 75W Light Bulbs 75 each 75 each 18 CU Ft Refrigerator / Freezer Furnace Fan (⅓ HP) Sump Pump (⅓ HP) Water Pump (⅓ HP) Heating/Cooling Table Fan Electric Blanket Space Heater Kitchen Blender Toaster (2 slice) Coffee Maker Electric Range (1 element) Dishwasher Laundry Room Iron Washing Machine Gas Clothes Dryer Bathroom Rated Watts Surge Watts Hair Dryer Curling Iron Family Room X-Box or Play Station 40 0 AM/FM Radio VCR Color TV (27 ) Fax Machine 65 0 Personal Computer (17 Monitor) Laser Printer Copy Machine Power Tools 1000W Quartz Halogen Work Light Airless Sprayer (⅓ HP) Reciprocity Saw Circular Saw (7 ¼ ) Mitar Saw (10 ) Table/Radial Arm Saw Electric Drill (½ HP, 5.4 Amps)

18 MAINTENANCE Regular maintenance will extend the life of this generator and improve its performance. The warranty does not cover items that result from operator negligence, misuse, or abuse. To receive full value from the warranty, operator must maintain the generator as instructed in this manual, including proper storage. Before inspecting or servicing this machine, make sure the engine is off and no parts are moving. Disconnect the spark plug wire and move it away from the spark plug. CAUTION! If you are unsure of how to perform a maintenance task, have the unit serviced by our dealers. CAUTION! Only use our spedified replacement parts. Maintenance Schedule Pre-Operation Steps Before starting the engine, perform the following pre-operation steps: Check the level of the engine oil and the fuel tank level. Check for any leakage. Check fuel hose for cracks or damage. Replace if necessary. pick up loose debris. If dirt is caked on, use a soft bristle brush. Inspect the work area for hazards. After Each Use Follow the following procedure after each use: Shut off engine. Store unit in a clean and dry area. After First 5 Hours Change Oil. After 8 Hours or Daily Clean Debris. Check Engine Oil Level. 6 Months (100 hr Use) Check and Clean Air Filter Element. (Service more often under wet or dusty conditions.) Change Engine Oil. (Service more often under dirty or dusty conditions.) Service Spark Plug. 12 Months (300 hr Use) Clean Fuel Filter. Replace if necessary. Check Crankcase Breather Hose for cracks or damage. Replace if necessary. De-carbonize cylinder head. See dealer. Check and adjust Valve Clearance. See dealer. Check all Fittings and Fasteners. See dealer. 18

19 MAINTENANCE Checking Spark Plug Remove cap. Then remove spark plug cap. Disconnect the spark plug wire from the spark plug. Before removing the spark plug, clean the area around its base to prevent debris from entering the engine. Insert a spark plug socket wrench through the opening on the outside of the cover. Turn the wrench counterclockwise. Check for discoloration and clean carbon deposits off the electrode with a wire brush. Check the electrode gap and slowly adjust to mm ( in) if necessary. Reinstall spark plug and tighten to Torque 20.0Nm (14.8ft-lb). If spark plug is worn replace only with an equivalent replacement part. Spark plug should be replaced annually. Reconnect spark plug wire. Replace spark plug cap, then replace cap mm Standard Spark Plug: E6TC/E6RT/BPR6HS Spark Plug Gap: mm ( in) Spark Plug Torque: 20.0Nm (14.8ft-lb) Carburetor Adjustment The carburetor is low emission and is equipped with a non-adjustable idle mixture valve. If adjustment is needed contact an authorized dealer. 19

20 MAINTENANCE Changing Oil Place generator on a level surface. Run the generator for several minutes until the engine is warm. Turn off generator. Remove screws, then remove outer casing. Remove the crankcase dipstick. Place an oil pan underneath the engine. Tilt generator to collect used oil. Allow oil to drain completely. Return generator to a level surface. (Crankcase Dipstick hole). Use a clean rag to wipe up any spilled oil. Replace crankcase dipstick. Reinstall outer casing and tighten screws. Recommended Engine Oil: SAE 10W-30 Recommended Engine Oil Grade: API Service SE type or higher quality of engine oil. Engine Oil Quantity: 0.35L (11.8oz) CAUTION! the engine. CAUTION! Make sure no foreign matter enters the crankcase 20

21 MAINTENANCE Air Filter To clean, remove the screws then remove outer casing. Remove the foam element. Wash the foam element in solvent and let dry. Pour a small amount of oil on the foam element then squeeze out, but do not wring out, excess oil. Foam element should be damp, but not dripping. CAUTION! Do not run the generator without reinstalling the foam element or excessive piston and cylinder wear may result. Check the muffler screen and spark arrester for damage.if damaged replace with Our replacement parts Install the outer casing and tighten the screws. Remove screws, then remove shown area of outer casing. Avoid contacting hot areas of this unit. Allow hot components to cool before touching. 21.

22 MAINTENANCE Fuel Tank Filter Install fuel cap. Fuel Filter To clean, remove screws, remove outer casing, and drain fuel. Lift and hold onto the clamp, then remove hose from tank. Install hose and clamp. Open fuel valve. Inspect for leakage. Install outer casing and tighten screws. Storage To protect your generator from deterioration during long term storage, take the following preventative measures: EXTERIOR pick up loose debris. If dirt is caked on, use a soft bristle brush. Inspect air cooling slots. Remove any debris if obstructed. Store indoors and use a protective cover to protect from dust. FUEL For short-term storage, add fuel stabilizer to prevent stale fuel from causing acid and gum deposits in the fuel system and carburetor. For long-term storage, drain the fuel. ENGINE Remove spark plug. Pour about 1 TBL of SAE 10W-30 engine oil into the spark plug hole, then reinstall spark plug. With the 3 in 1 switch in the OFF position, pull the recoil starter several times to coat cylinder walls with oil. Slowly pull the recoil starter until you feel the engine build compression (when you feel resistance). Leave the engine in this state. This will help prevent rust build up in the cylinder walls. 22

23 MAINTENANCE How to drain fuel Turn the 3 in 1 switch to the OFF position. Use a siphon to transfer gasoline from generator into a gasoline approved container. Wipe up any spilled fuel with a clean rag. Start generator engine and let it run until it stops and all remaining fuel is consumed. Do not connect electronic devices to generator during this process. Remove outer casing screws, then remove outer casing.. Turn the 3 in 1 switch to OFF Tighten the drain screw. Install the outer casing and tighten screws. When the engine has completely cooled down, turn the Fuel Cap Air Vent to the OFF position. 23

24 TROUBLESHOOTING Problem Cause Solution Generator is running, but does not supply power. Engine runs good without load but bogs down when loads are connected Engine will not start, shuts down during operation, or starts and runs rough. 1. DC Circuit Breaker is OFF 2. Green AC Pilot Light Indicator is off. 3. Poor connection 4. Defective cord set 5. Connected device is faulty 6. Fault in generator 1. Short circuit in connected device 2. Generator is overloaded 4. Engine speed is too slow 5. Short circuit in generator 1. 3 in 1 switch set to OFF 1. Turn DC Circuit Breaker ON 2. Stop engine and restart. 3. Check and repair 4. Check and repair 5. Connect a device that is working properly 6. Contact service department 1. Disconnect device 2. See pg 17 Don t overload generator 4. Contact service department 5. Contact service department 1. Turn switch to CHOKE then pull recoil starter. Engine lacks power Engine hunts or falters 4. Out of fuel or Stale fuel 5. Spark plug wire disconnected from spark plug 6. Bad spark plug 7. Water in fuel 8. Overchocking 9. Low oil level 11. Faulty ignition 1. Generator is overloaded 4. Engine needs servicing 1. Choke was removed too soon 3. Carburetor is running too rich or too lean 4. Replace fuel 5. Reconnect spark plug wire 6. Clean or replace spark plug 7. Drain fuel tank and replace fuel 8. Turn off choke 9. Add oil level. 10. Wait 5 minutes and recrank engine 11. Contact our dealer 1. See pg 17 Don t overload generator 4. Contact service department 1. Move to choke until engine runs evenly 3. Contact service department 24

25 DIAGRAMS Generator Engine Generator Set Model No. 2200I Type Inverter Rated Frequency 60Hz Rated Voltage 120V Maximum Output Power 2.2kW Rated Output Power 1.7kW Power Factor 1.0 AC Output Quality ISO8528 G1 THD 3% Noise Level 58-60dBA DC Output 12V/8A DC Non-Fuse Protector Overload Frequency Regulator Overload Protect AC Protection Process Control Engine DH80i Engine Type Single Cylinder, 4-Stroke, Forced Air Cooling, OHV Displacement 80cc Fuel Type Unleaded Gasoline Fuel Tank Capacity 4.5L Continued Running Time (At Rated Power) 4h Fuel Tank Capacity 350ml Spark Plug Model No. E6TC/E6RTC Starting Mode Recoil Starter Length Width Height mm Net Weight 21kg 25

26 WIRING DIAGRAM W W! P /1

OPERATOR S MANUAL. Model: PG4000iSR. Inverter Gasoline.

OPERATOR S MANUAL. Model: PG4000iSR. Inverter Gasoline. TM Model: PG4000iSR Inverter Gasoline OPERATOR S MANUAL Warning: The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive

More information

OPERATOR S MANUAL. Model: PG2000iS. Inverter Gasoline.

OPERATOR S MANUAL. Model: PG2000iS. Inverter Gasoline. Model: PG2000iS Inverter Gasoline OPERATOR S MANUAL Warning: The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive

More information

8500M INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL

8500M INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL 8500M INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL IT IS EXTREMELY IMPORTANT TO READ AND UNDERSTAND THE ENTIRE CONTENTS OF THIS OPERATOR S MANUAL BEFORE ATTEMPTING TO OPERATE THE PRODUCT. THIS EQUIPMENT

More information

9000RC INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL

9000RC INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL 9000RC INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL IT IS EXTREMELY IMPORTANT TO READ AND UNDERSTAND THE ENTIRE CONTENTS OF THIS OPERATOR S MANUAL BEFORE ATTEMPTING TO OPERATE THE PRODUCT. THIS EQUIPMENT

More information

9500M. WARNING American Fab of SC, LLC Travelers Rest, SC OPERATOR S MANUAL INDUSTRIAL GASOLINE GENERATOR

9500M. WARNING American Fab of SC, LLC Travelers Rest, SC OPERATOR S MANUAL INDUSTRIAL GASOLINE GENERATOR 9500M INDUSTRIAL GASOLINE GENERATOR OPERATOR S MANUAL WARNING American Fab of SC, LLC Travelers Rest, SC It is extremely important to read and understand the entire contents of this operator s manual before

More information

ITEM#: PG1202S Generator OPERATOR S MANUAL

ITEM#: PG1202S Generator OPERATOR S MANUAL ITEM#: PG1202S Generator OPERATOR S MANUAL Warning: The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. INTRODUCTIONS

More information

PowerMaxConverters.com

PowerMaxConverters.com Inverter Gasoline OPERATOR S MANUAL Model: PMG4000iSR Warning: The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive

More information

3kW GENERATOR. Owner s Manual

3kW GENERATOR. Owner s Manual 3kW GENERATOR SILENT INVERTER GASOLINE ENGINE GENERATOR Owner s Manual ORIGINAL INSTRUCTION Thank you for choosing a silent inverter gasoline engine generator set of our company. This manual contains

More information

Generator OPERATOR S MANUAL

Generator OPERATOR S MANUAL ITEM#: PG1202S Generator OPERATOR S MANUAL Warning: The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. www.pulsar-products.com

More information

Gasoline Inverter Generator

Gasoline Inverter Generator user manual Gasoline Inverter Generator table of contents Preface Introduction... Safety Information Exhaust fumes are poisonous... Fuel is highly flammable and poisonous... Engine and muffler may be hot...

More information

KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC.

KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC. KING CANADA 950W PORTABLE GENERATOR MODEL: KCG-951G INSTRUCTION MANUAL COPYRIGHT 2011 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC. WARRANTY & SERVICE INFORMATION 1-YEAR LIMITED WARRANTY FOR THIS 950W

More information

Generator OPERATOR S MANUAL. Model: FG6250E ITEM# F10525E99.

Generator OPERATOR S MANUAL. Model: FG6250E ITEM# F10525E99. Generator OPERATOR S MANUAL Model: FG6250E ITEM# F10525E99 www.fordpower.cc TABLE OF CONTENTS Introduction...3 Product Specifications...3 Parts Ordering / Customer Service...3 Safety Rules...4 Safety Symbols...4

More information

PORTABLE INVERTER GENERATOR MODEL

PORTABLE INVERTER GENERATOR MODEL 3200Watts PORTABLE INVERTER GENERATOR MODEL #104612 Operation Manual This safety alert symbol identifies important safety messages in this manual. Failure to follow this important safety information may

More information

1200W INVERTER GENERATOR

1200W INVERTER GENERATOR 1200W INVERTER GENERATOR MODEL NO: IG1200 PART NO: 8877070 OPERATION & MAINTENANCE INSTRUCTIONS LS0117 INTRODUCTION Thank you for purchasing this CLARKE 1200W Inverter Generator. Before attempting to use

More information

GASOLINE GENERATOR SET SPG8000 PORTABLE GENERATOR INSTRUCTION MANUAL IMPORTANT!

GASOLINE GENERATOR SET SPG8000 PORTABLE GENERATOR INSTRUCTION MANUAL IMPORTANT! GASOLINE GENERATOR SET SPG8000 PORTABLE GENERATOR INSTRUCTION MANUAL IMPORTANT! Please make certain that persons who are to use this equipment thoroughly read and understand these instructions and any

More information

YK1900i DIGITAL INVERTER GASOLINE GENERATOR OWNER S MANUAL PLEASE READ THIS MANUAL CAREFULLY. IT CONTAINS IMPORTANT SAFETY INFORMATION.

YK1900i DIGITAL INVERTER GASOLINE GENERATOR OWNER S MANUAL PLEASE READ THIS MANUAL CAREFULLY. IT CONTAINS IMPORTANT SAFETY INFORMATION. YK1900i DIGITAL INVERTER GASOLINE GENERATOR OWNER S MANUAL PLEASE READ THIS MANUAL CAREFULLY. IT CONTAINS IMPORTANT SAFETY INFORMATION. PREFACE Thank you for purchasing YANGKE generator. This manual covers

More information

GASOLINE GENERATOR SET USER S MANUAL

GASOLINE GENERATOR SET USER S MANUAL GASOLINE GENERATOR SET USER S MANUAL Foreword Thank you for purchasing our gasoline generator and hope that you will enjoy operating your unit, one of the finest models in the market. This Manual provides

More information

950 Watts (104609) /1200Watts (104610) /2000Watts (104611) PORTABLE INVERTER GENERATORS. MODELS #104609, # and #

950 Watts (104609) /1200Watts (104610) /2000Watts (104611) PORTABLE INVERTER GENERATORS. MODELS #104609, # and # 950 Watts (104609) /1200Watts (104610) /2000Watts (104611) PORTABLE INVERTER GENERATORS MODELS #104609, #104610 and #104611 Operation Manual This safety alert symbol identifies important safety messages

More information

Reproduction. Not for. Wiring Diagram. Model / Modelo Mfg. No. Description / Descripción

Reproduction. Not for. Wiring Diagram. Model / Modelo Mfg. No. Description / Descripción Wiring Diagram This generator is rated in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-94 (motor and generators). Questions? Help is just a moment away! Preguntas? La ayuda

More information

HD675, HD775 Owner's Manual

HD675, HD775 Owner's Manual EN ESS HD675, HD775 Owner's Manual FRC IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Refer to operating instruction of equipment that this engine powers.

More information

3250 3250 1-866-591-8921 The generator is a potential source of electrical shock if misused. Do not expose the generator to moisture, rain or snow. Do not let the generator get wet, and do not operate

More information

1100W PORTABLE GENERATOR

1100W PORTABLE GENERATOR 1100W PORTABLE GENERATOR MODEL NO: G1200 PART NO: 8010110 OPERATION & MAINTENANCE INSTRUCTIONS LS0312 INTRODUCTION Thank you for purchasing this CLARKE 1100W Portable Generator. Before attempting to use

More information

5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616

5.5KVA GENERATOR MODEL NO: PG6500DVES OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0616 5.5KVA GENERATOR MODEL NO: PG6500DVES PART NO: 8857810 OPERATION & MAINTENANCE INSTRUCTIONS LS0616 INTRODUCTION Thank you for purchasing this CLARKE 5.5KVA Generator. Before attempting to use this product,

More information

SGB12000HX PORTABLE GENERATOR

SGB12000HX PORTABLE GENERATOR 12KWG022004KOD PRINTED IN CANADA SGB12000HX PORTABLE GENERATOR OPERATING INSTRUCTIONS AND PARTS MANUAL John Brooks Company Limited Mississauga, Ontario L5N 7K5 12 1 Troubleshooting The majority of problems

More information

4000W GASOLINE DIGITAL INvERTER GENERATOR

4000W GASOLINE DIGITAL INvERTER GENERATOR 04/2017 4000W GASOLINE DIGITAL INvERTER GENERATOR Read this manual. Do not attempt to operate this generator until you have read and understood the safety, operation, and maintenance instructions MODEL:

More information

Gas Powered Generator Operator s Manual

Gas Powered Generator Operator s Manual Gas Powered Generator Operator s Manual BNG2000 (2KW) BNG3000 (3KW) BNG5000 (5KW) BNG6500 (6.5KW) BNG7500 (7.5KW) Page 1 Generator_Instruction_Manual May 17, 2017 Contents INTRODUCTION... 3 SAFETY RULES...

More information

GEN2000 i 2,000 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL

GEN2000 i 2,000 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL GEN2000 i 2,000 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.

More information

Owner s Manual ELECTRIC GENERADORS R7100DP / G7100G

Owner s Manual ELECTRIC GENERADORS R7100DP / G7100G Owner s Manual ELECTRIC GENERADORS R7100DP / G7100G Thank you for choosing a generator set of our company. This manual contains the information on how to do that. Please read it carefully before operating.

More information

EZT715-EZT750 Owner's Manual

EZT715-EZT750 Owner's Manual EN EZT715-EZT750 Owner's Manual ESS FRC IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Refer to operating instruction of equipment that this engine powers.

More information

INVERTER GENERATOR P2000i

INVERTER GENERATOR P2000i INVERTER GENERATOR P2000i Operating Manual We Appreciate Your Business. Thank you and congratulations on choosing PRAMAC. This Operating Manual has been designed to instruct you on the correct use and

More information

GENERATOR MODEL NO: FG3005 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0413

GENERATOR MODEL NO: FG3005 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0413 GENERATOR MODEL NO: FG3005 PART NO: 8857707 OPERATION & MAINTENANCE INSTRUCTIONS LS0413 INTRODUCTION Thank you for purchasing this CLARKE Generator. Before attempting to use this product, please read this

More information

Owner s Manual. GENERATOR EU2000i. o Honda Motor Co., Ltd. -All Rights Reserved. See page 82 for Initial Use Instructions

Owner s Manual. GENERATOR EU2000i. o Honda Motor Co., Ltd. -All Rights Reserved. See page 82 for Initial Use Instructions Owner s Manual GENERATOR EU2000i o2001-2009 Honda Motor Co., Ltd. -All Rights Reserved See page 82 for Initial Use Instructions The engine exhaust from this product contains chemicals known to the State

More information

WARNING: Read these instructions before using the machine GENERATOR MODEL NO: IG3500F PART NO: OPERATION & MAINTENANCE INSTRUCTIONS

WARNING: Read these instructions before using the machine GENERATOR MODEL NO: IG3500F PART NO: OPERATION & MAINTENANCE INSTRUCTIONS WARNING: Read these instructions before using the machine GENERATOR MODEL NO: IG3500F PART NO: 8877100 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0217 INTRODUCTION Thank you for purchasing

More information

ZT710-ZT740 Owner's Manual

ZT710-ZT740 Owner's Manual EN ZT710-ZT740 Owner's Manual ESS FRC IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Refer to operating instruction of equipment that this engine powers.

More information

PORTABLE TRASH PUMPS MTP200 MTP300 MTP400

PORTABLE TRASH PUMPS MTP200 MTP300 MTP400 PORTABLE TRASH PUMPS MTP200 MTP300 MTP400 OPERATING & PARTS MANUAL INTRODUCTION This manual provides information and procedures to safely operate and maintain the engine and pump. For your own safety and

More information

3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV

3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV 3KVA DUAL VOLTAGE GENERATOR MODEL NO: PG3800DV PART NO: 8857815 OPERATION & MAINTENANCE INSTRUCTIONS LS1016 INTRODUCTION Thank you for purchasing this CLARKE 3KVA Dual Voltage Generator. Before attempting

More information

OWNER S MANUAL Titan 6500 Industrial Generator

OWNER S MANUAL Titan 6500 Industrial Generator P.O.Box 791, Travelers Rest, S.C. 29690 Phone 864-834-7212 Service/Replacement Parts 800-845-4141 OWNER S MANUAL Titan 6500 Industrial Generator The Emission Control System for this generator is warranted

More information

XTX650, XTX675, XTX775, XTX950, XTX1100 Owner's Manual

XTX650, XTX675, XTX775, XTX950, XTX1100 Owner's Manual EN ESS XTX650, XTX675, XTX775, XTX950, XTX1100 Owner's Manual FRC IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Refer to operating instruction of equipment

More information

720W PORTABLE GENERATOR

720W PORTABLE GENERATOR 720W PORTABLE GENERATOR MODEL NO: G720 PART NO: 8857800 OPERATION & MAINTENANCE INSTRUCTIONS LS0214 INTRODUCTION Thank you for purchasing this CLARKE 720W Portable Generator Before attempting to use this

More information

5625W GASOLINE GENERATOR WITH WHEEL KIT

5625W GASOLINE GENERATOR WITH WHEEL KIT 5625W GASOLINE GENERATOR WITH WHEEL KIT Read this manual. Do not attempt to operate this generator until you have read and understood the safety, operation, and maintenance instructions MODEL: KCG-5625G

More information

Genquip Gi1000 Digital Inverter Petrol Generator. Owners Manual

Genquip Gi1000 Digital Inverter Petrol Generator. Owners Manual Owners Manual page 1 Notes page 2 Table of Contents Control Function 4 Pre Operation Checklist 5 Fuel System Check Fuel Level Control Function 6 Engine Oil Oil Warning System Engine Switch DC Protector

More information

LDG6000SA DIESEL GENERATOR OWNERS MANUAL

LDG6000SA DIESEL GENERATOR OWNERS MANUAL LDG6000SA DIESEL GENERATOR OWNERS MANUAL BEFORE OPERATING THIS EQUIPMENT PLEASE READ THESE INSTRUCTIONS CAREFULLY Preface Thank-you for purchasing this generator. This operation manual contains information

More information

OWNERS MANUAL. Product Support

OWNERS MANUAL. Product Support Product Support OWNERS MANUAL Product Information, Application, Service Info & Warranty Questions Please email us at support@duromaxgenerators.com or call (800) 629-3325 Monday Friday 6:00 am 6:00 pm (PST)

More information

KS530-KS595 Owner's Manual

KS530-KS595 Owner's Manual EN ESS KS530-KS595 Owner's Manual FRC IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Refer to operating instruction of equipment that this engine powers.

More information

SV471-SV601 Owner's Manual

SV471-SV601 Owner's Manual EN ESS SV471-SV601 Owner's Manual FRC IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Refer to operating instruction of equipment that this engine powers.

More information

PW2750 HOT WATER HI PRESSURE WASHER INSTRUCTION MANUAL

PW2750 HOT WATER HI PRESSURE WASHER INSTRUCTION MANUAL 4/10/2012 PW2750 HOT WATER HI PRESSURE WASHER INSTRUCTION MANUAL READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.

More information

PORTABLE TRASH PUMPS MDP200

PORTABLE TRASH PUMPS MDP200 PORTABLE TRASH PUMPS MDP200 OPERATING & PARTS MANUAL INTRODUCTION This manual provides information and procedures to safely operate and maintain the engine and pump. For your own safety and protection

More information

Generator OPERATOR S MANUAL. Model: PG5250.

Generator OPERATOR S MANUAL. Model: PG5250. Generator OPERATOR S MANUAL Model: PG5250 www.pulsar-products.com TABLE OF CONTENTS Introduction...3 Product Specifications...3 Parts Ordering / Customer Service...3 Safety Rules...4 Safety Symbols...4

More information

AIR-COOLED DIESEL GENERATOR OWNERʼS MANUAL. This manual contains important safety information. TDG2500E TDGW7000E TDG7000SE TDG4500E

AIR-COOLED DIESEL GENERATOR OWNERʼS MANUAL. This manual contains important safety information. TDG2500E TDGW7000E TDG7000SE TDG4500E AIR-COOLED DIESEL GENERATOR OWNERʼS MANUAL This manual contains important safety information. TDG2500E TDGW7000E TDG7000SE TDG4500E TDG8000-3 TDG7000SE-3 TDG7000E TDG8000E TDGW7000SE TDG7000E3 TDGW8000E

More information

KT715-KT745 Owner's Manual

KT715-KT745 Owner's Manual EN KT715-KT745 Owner's Manual ESS FRC IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Refer to operating instruction of equipment that this engine powers.

More information

MODEL cc Generator

MODEL cc Generator MODEL 4750 223 cc Generator Item # 56475 Owner s Manual Manual del Propietario Questions? Problems? Please call our customer help line: (800) 232-1195 M-F 8-5 CST FEATURES 4750 Surge Watt Output 3750 Rated

More information

CH940-CH1000 CV940-CV1000 Owner's Manual

CH940-CH1000 CV940-CV1000 Owner's Manual CH940-CH1000 CV940-CV1000 Owner's Manual IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Refer to operating instruction of equipment that this engine powers.

More information

1000 RATED WATTS/1200 MAXIMUM WATTS PORTABLE POWER GENERATOR

1000 RATED WATTS/1200 MAXIMUM WATTS PORTABLE POWER GENERATOR 1000 RATED WATTS/1200 MAXIMUM WATTS PORTABLE POWER GENERATOR 1200 W P OW E R G E N E R ATO R MODEL # 101174 Operation Manual This safety alert symbol identifies important safety messages in this manual.

More information

SH255, SH265 Owner's Manual

SH255, SH265 Owner's Manual EN DE SH255, SH265 Owner's Manual ESE ESS FRC FRF HR ID IT PT RO RU SL TR ZH IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Refer to operating instruction

More information

GENERATOR MODEL NO: FG2500 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0114

GENERATOR MODEL NO: FG2500 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0114 GENERATOR MODEL NO: FG2500 PART NO: 8857727 OPERATION & MAINTENANCE INSTRUCTIONS LS0114 INTRODUCTION Thank you for purchasing this CLARKE Generator. Before attempting to use this product, please read this

More information

Owner s Manual. GENERATOR EU1000i. o2013 Honda Motor Co., Ltd. -All Rights Reserved. See page 84 for Initial Use Instructions

Owner s Manual. GENERATOR EU1000i. o2013 Honda Motor Co., Ltd. -All Rights Reserved. See page 84 for Initial Use Instructions Owner s Manual GENERATOR EU1000i o2013 Honda Motor Co., Ltd. -All Rights Reserved See page 84 for Initial Use Instructions The engine exhaust from this product contains chemicals known to the State of

More information

General Power Products

General Power Products Portable Electric Generator Owners Manual MODEL: APP 6000 General Power Products IMPORTANT Please make certain the person who uses this Generator thoroughly reads these instructions and all other instructions

More information

AC2T & AC2T-ES INDUSTRIAL GASOLINE AIR COMPRESSOR

AC2T & AC2T-ES INDUSTRIAL GASOLINE AIR COMPRESSOR AC2T & AC2T-ES INDUSTRIAL GASOLINE AIR COMPRESSOR INDUSTRIAL GAS AIR COMPRESSOR OPERATOR S MANUAL IT IS ETREMELY IMPORTANT TO READ AND UNDERSTAND THE ENTIRE CONTENTS OF THIS OPERATOR S MANUAL BEFORE ATTEMPTING

More information

OPERATING AND MAINTENANCE INSTRUCTIONS. Generator Models SXA1900HX, SXA2800HX,SXB2800HX SXB4000HX, SXB5500HX(S), SXB7000HX(S)

OPERATING AND MAINTENANCE INSTRUCTIONS. Generator Models SXA1900HX, SXA2800HX,SXB2800HX SXB4000HX, SXB5500HX(S), SXB7000HX(S) GASOLINE POWERED PORTABLE GENERATORS OPERATING AND MAINTENANCE INSTRUCTIONS Generator Models SXA1900HX, SXA2800HX,SXB2800HX SXB4000HX, SXB5500HX(S), SXB7000HX(S) JOHN BROOKS COMPANY LIMITED TORONTO - MONTREAL

More information

Make/Type/Size/Model Honda Generator EB 3500X & EB5000X Operators Manual Open Well Ventilated Area to Start & Shut Down Machine

Make/Type/Size/Model Honda Generator EB 3500X & EB5000X Operators Manual Open Well Ventilated Area to Start & Shut Down Machine HONDA GENERATORS ARE DESIGNED TO GIVE SAFE AND DEPENDABLE SERVICE IF OPERATED ACCORDING TO INSTRUCTIONS. YOU CAN HELP PREVENT ACCIDENTS BY BEING FAMILIAR WITH YOUR GENERATORS CONTROLS AND BY OBSERVING

More information

WUXI KIPOR POWER CO., LTD. DIGITAL INVERTER GENERATOR

WUXI KIPOR POWER CO., LTD. DIGITAL INVERTER GENERATOR R R WUXI KIPOR POWER CO., LTD. SINEMASTER DIGITAL INVERTER GENERATOR IG2000 IG2000s IG2000p PREFACE Thank you for purchasing our generators. This manual covers operation and maintenance of the IG2000,

More information

Light condition and operation Windshield glass condition Wiper blade condition Paint condition and corrosion Fluid leaks Door and hood lock condition

Light condition and operation Windshield glass condition Wiper blade condition Paint condition and corrosion Fluid leaks Door and hood lock condition GENERAL CHECKS Engine Compartment The following should be checked regularly: Engine oil level and condition Transmission fluid level and condition Brake fluid level Clutch fluid level Engine coolant level

More information

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI 15 GALLON AIR COMPRESSOR Model: 7678 DO NOT RETURN TO STORE Please call 800-348-5004 for parts and service CALIFORNIA PROPOSITION 65 WARNING: You can create dust when you cut, sand, drill or grind materials

More information

PF-4000, PF-4010, PF-4210 MULTI-PURPOSE ENGINE

PF-4000, PF-4010, PF-4210 MULTI-PURPOSE ENGINE PF-4000, PF-4010, PF-4210 MULTI-PURPOSE ENGINE Date 09-26-01 Supplier To The Outdoor Power Equipment Industry ISM, Inc. 1028 4 th Street SW Auburn, WA 98001 Phone: (253) 333-1200 Fax: (253) 333-1212 WWW.TANAKA-USA.COM

More information

GEN Surge Watts / 1500 Running Watts PORTABLE GENERATOR INSTRUCTION MANUAL

GEN Surge Watts / 1500 Running Watts PORTABLE GENERATOR INSTRUCTION MANUAL GEN154 2000 Surge Watts / 1500 Running Watts PORTABLE GENERATOR INSTRUCTION MANUAL READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation

More information

GENERAC. The Reliable Ones SE5000. Portable Generator Owner s Manual

GENERAC. The Reliable Ones SE5000. Portable Generator Owner s Manual GENERAC The Reliable Ones SE5000 Portable Generator Owner s Manual DANGER! This generator is designed for outdoor use only. Never use this generator inside any building or enclosure including the generator

More information

Part No FJ180V KAI. 4-stroke air-cooled gasoline engine OWNER, S MANUAL

Part No FJ180V KAI. 4-stroke air-cooled gasoline engine OWNER, S MANUAL Part No. 99920-2280-02 FJ180V KAI 4-stroke air-cooled gasoline engine OWNER, S MANUAL SAFETY AWARENESS FOREWORD TABLE OF CONTENTS Whenever you see the symbols shown below, heed their instructions! Always

More information

GEN3500 i 3,000 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL

GEN3500 i 3,000 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL GEN3500 i 3,000 MAX WATTS INVERTER GENERATOR INSTRUCTION MANUAL READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.

More information

Generator OWNER S MANUAL. Read this manual carefully before operating this machine. PRO 2.8 i 7VU L1

Generator OWNER S MANUAL. Read this manual carefully before operating this machine. PRO 2.8 i 7VU L1 Generator OWNER S MANUAL Read this manual carefully before operating this machine. PRO.8 i 7VU-899-L - Read this manual carefully before operating this machine. This manual should stay with this machine

More information

These labels warn you of potential hazards that can cause serious injury. Read them carefully.

These labels warn you of potential hazards that can cause serious injury. Read them carefully. 6000 6000 The generator is a potential source of electrical shock if misused. Do not expose the generator to moisture, rain or snow. Do not let the generator get wet, and do not operate it with wet hands.

More information

No part of this publication may be reproduced without written permission.

No part of this publication may be reproduced without written permission. Thank you for purchasing a Honda generator. This manual covers operation and maintenance of the EB3000 and EB4000 generators. All information in this publication is based on the latest product information

More information

Commercial Series Generator Operator Manual (with Kohler Command series engines)

Commercial Series Generator Operator Manual (with Kohler Command series engines) Commercial Series Generator Operator Manual (with Kohler Command series engines) PN: 220880 PREFACE Thank you for purchasing a Wanco Commercial Series portable generator set. This manual contains important

More information

Owner s Manual. GENERATOR EB2000i. o2013 Honda Motor Co., Ltd. -All Rights Reserved. See page 78 for Initial Use Instructions

Owner s Manual. GENERATOR EB2000i. o2013 Honda Motor Co., Ltd. -All Rights Reserved. See page 78 for Initial Use Instructions Owner s Manual GENERATOR EB2000i o2013 Honda Motor Co., Ltd. -All Rights Reserved See page 78 for Initial Use Instructions The engine exhaust from this product contains chemicals known to the State of

More information

CH682, CH732, CH742, CH752 CV682, CV732, CV742, CV752 Owner's Manual

CH682, CH732, CH742, CH752 CV682, CV732, CV742, CV752 Owner's Manual EN ESS CH682, CH732, CH742, CH752 CV682, CV732, CV742, CV752 Owner's Manual FRC IMPORTANT: Read all safety precautions and instructions carefully before operating equipment. Refer to operating instruction

More information

MODEL HP Generator

MODEL HP Generator MODEL 3500 7 HP Generator Item # 56352 Owner s Manual Manual del Propietario Questions? Problems? Please call our customer help line: (800) 232-1195 M-F 8-5 CST FEATURES 3500 Surge Watt Output 3000 Rated

More information

2000 WATT DIGITAL GENERATOR

2000 WATT DIGITAL GENERATOR APG3102 TM Owner s Manual 2000 WATT DIGITAL GENERATOR Distributed by: ALL-POWER AMERICA 2005 ALL-POWER AMERICA 16273 E. Gale Ave City Of Industry, California 91745 www.allpoweramerica.com www.allpoweramerica.com

More information

Inverter Generator. Operator s Manual

Inverter Generator. Operator s Manual Inverter Generator Operator s Manual This generator is rated in accordance with CSA (Canadian Standards Association) standard C22.2 No. 100-14 (motors and generators). BRIGGS & STRATTON POWER PRODUCTS

More information

OWNER S MANUAL. 2.4kVA Portable Petrol Inverter Generator

OWNER S MANUAL. 2.4kVA Portable Petrol Inverter Generator OWNER S MANUAL 2.4kVA Portable Petrol Inverter Generator Thank you for purchasing your Cromtech Outback 2.4kVA portable petrol inverter generator. This manual provides understanding of the operation and

More information

Application/Equipment Rated Watts (Running) Maximum Watts (Starting) Light Bulb 75W Refrigerator/Freezer TOTALS

Application/Equipment Rated Watts (Running) Maximum Watts (Starting) Light Bulb 75W Refrigerator/Freezer TOTALS Generator Selecting a Generator You must know the rated and maximum wattage for appliances to be used with a generator. Appliances with electric motors may require 2-3 times the rated power when starting

More information

GT2600. Introduction. Description Of Symbols. Specifications. Environmental Protection. Scope Of Product

GT2600. Introduction. Description Of Symbols. Specifications. Environmental Protection. Scope Of Product Contents Introduction...3 Environmental Protection...3 Scope of Product...3 Description of Symbols...3 Specifications...3 Safety Rules...4 Unpacking the Generator...6 Features and Controls...7 Preparation

More information

Introduction INTRODUCTION READ THIS MANUAL THOROUGHLY GENERAL HAZARDS SAFETY RULES

Introduction INTRODUCTION READ THIS MANUAL THOROUGHLY GENERAL HAZARDS SAFETY RULES Introduction INTRODUCTION Thank you for purchasing this model by Generac Power Systems, Inc. This model is a compact, high performance, air-cooled, engine driven generator designed to supply electrical

More information

Owner s Manual. GENERATOR EU3000i. o2009 Honda Motor Co., Ltd. -All Rights Reserved. See page 83 for Initial Use Instructions

Owner s Manual. GENERATOR EU3000i. o2009 Honda Motor Co., Ltd. -All Rights Reserved. See page 83 for Initial Use Instructions Owner s Manual GENERATOR EU3000i o2009 Honda Motor Co., Ltd. -All Rights Reserved See page 83 for Initial Use Instructions The engine exhaust from this product contains chemicals known to the State of

More information

TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL

TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL IT IS EXTREMELY IMPORTANT TO READ AND UNDERSTAND THE ENTIRE CONTENTS OF THIS OPERATOR S MANUAL BEFORE ATTEMPTING TO OPERATE THE PRODUCT. THIS EQUIPMENT IS

More information

EZV2000P_UG_EN_

EZV2000P_UG_EN_ ezv2000p USER GUIDE This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more

More information

7000 RATED WATTS/8750 MAXIMUM WATTS PORTABLE POWER GENERATOR

7000 RATED WATTS/8750 MAXIMUM WATTS PORTABLE POWER GENERATOR 30A 7000 RATED WATTS/8750 MAXIMUM WATTS PORTABLE POWER GENERATOR 8 7 5 0 W P O W E R G E N E R AT O R START MODEL # 101175 Operation Manual This safety alert symbol identifies important safety messages

More information

Owner s Manual PORTABLE GENERATOR. Model: PR2800 PR6500

Owner s Manual PORTABLE GENERATOR. Model: PR2800 PR6500 PORTABLE GENERATOR Owner s Manual Model: PR2800 PR6500 ALLPOWER INDUSTRIES AUSTRALIA A.B.N 46 650 681 742 Unit 5, 102-128 Bridge Road, Keysborough, VIC 3173, Australia Telephone: +61 38726 1444 / 1800

More information

2-Stroke 900 Rated Watt Generator

2-Stroke 900 Rated Watt Generator 2-Stroke 900 Rated Watt Generator Item # 56100 Owner s Manual Manual del Propietario FEATURES: 1000 Surge Watt Output 900 Rated Watt Output (7.5Amps at 120Volts) 2 HP Single Cylinder 2-Stroke Engine One

More information

030212 (2.5 kw) 030213 (2.8 kw) Owner s Manual Before using this product, read this manual and follow all Safety Rules and Operating Instructions. Questions? Help is just a moment away! Find your Briggs

More information

Fig. 1. Fig. 2. Fig. 3. Fig. 5. Fig. 4. AC Breaker. DC Breaker. Carburetor Drain Screw. Fuel Tank. Fuel Cap. Fuel Filter. Fuel Valve.

Fig. 1. Fig. 2. Fig. 3. Fig. 5. Fig. 4. AC Breaker. DC Breaker. Carburetor Drain Screw. Fuel Tank. Fuel Cap. Fuel Filter. Fuel Valve. AC Breaker DC Breaker Fig. 1 Carburetor Drain Screw Fig. 2 Fuel Cap Fuel Tank Fuel Filter Fuel Valve Choke Lever Air Filter Recoil Starter Grip Oil Cap/dipstick Fig. 3 Fuel Cap Fuel Tank Oil Cap/ Dipstick

More information

EZV2000S_UG_EN_

EZV2000S_UG_EN_ ezv2000s USER GUIDE This product can expose you to chemicals including carbon monoxide, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more

More information

AG-HA-2500N GASOLINE GENERATOR

AG-HA-2500N GASOLINE GENERATOR AG-HA-2500N GASOLINE GENERATOR OWNER S MANUAL BEFORE OPERATING THIS EQUIPMENT PLEASE READ THESE INSTRUCTIONS CAREFULLY (I)WARNING 1. Read the operator s instruction manual. 2. Attention! Exhaust gases

More information

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609

GENERATOR MODEL NO: FG3000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS0609 GENERATOR MODEL NO: FG3000 PART NO: 8857700 OPERATION & MAINTENANCE INSTRUCTIONS LS0609 INTRODUCTION Thank you for purchasing this CLARKE Generator. Before attempting to use this product, please read this

More information

Earth Auger MAG500 MAG500RS

Earth Auger MAG500 MAG500RS Earth Auger MAG500 MAG500RS US Owner s/operator s Manual Completely read and understand this manual before using this product. - 0 - Foreword This Owner s/ Operator s Manual is designed to familiarize

More information

INVERTER GENERATOR Owner's Manual

INVERTER GENERATOR Owner's Manual INVERTER GENERATOR Owner's Manual 2000i Tips- read this manual carefully before operating this generator. Save this operating manual properly and carry it with the generator for the convenience of emergency

More information

Owner's Manual. XG Series 6,500-8,000 Watt Portable Generator. or

Owner's Manual. XG Series 6,500-8,000 Watt Portable Generator.  or MODELS: 005796-0 (XG6500), 005797-0 (XG7000), 005798-0 (XG7000E), 005800-0 (XG8000), 005747-0 (XG8000E) Owner's Manual XG Series 6,500-8,000 Watt Portable Generator www.generac.com or 1-888-436-3722 Table

More information

Digital Inverter Generator DG-3500

Digital Inverter Generator DG-3500 Digital Inverter Generator DG-3500 OPERATING INSTRUCTIONS PLEASE READ THIS MANUAL CAREFULLY BEFORE USING MACHINE Thank you for using our generator. PREFACE This manual includes the operation and maintenance

More information

AUTOMOTIVE POWER INVERTERS INSTRUCTIONS. Item #31463, #31464, #31465

AUTOMOTIVE POWER INVERTERS INSTRUCTIONS. Item #31463, #31464, #31465 AUTOMOTIVE POWER INVERTERS INSTRUCTIONS Item #31463, #31464, #31465 EASTWOOD AUTOMOTIVE POWER INVERTERS are heavy-duty professional grade pieces of equipment designed to bring 120 volt power to any automobile.

More information

Water pump Owner's Manual

Water pump Owner's Manual Water pump Owner's Manual Safety Precautions I. General Safeguards Please read this operation manual to have a thorough understanding of the content there before use the product. Failure to do so may lead

More information

PLEASE READ THIS MANUAL

PLEASE READ THIS MANUAL POWERHOUSE PH2700PRi Digital Inverter Generator OWNER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE USING QUICK START Pre-Operation: Use outdoors only. Generators produce carbon monoxide a poisonous,

More information

POLARIS POWER P3000iE

POLARIS POWER P3000iE PMS 419 POLARIS POWER P3000iE Operator s Manual (Australian model) Failure to properly follow the instructions and precautions in this manual can result in property damage, serious injury or DEATH! For

More information