1 2015 TOTALINE HVAC/R PARTS CATALOG WHAT ARE YOU WORKING ON TODAY? TM UTC, Business-Industrial-Systems (BIS) Carrier Corporation Printed in the U.S.A. Edition Date: 02/2015

2 Table of Contents Categorized Listing 1 TOTALINE CAPACITORS 2 Genaral Information 2 Oval Motor Run Capacitor - Dual 3 Oval Motor Run Capacitor - Single 4 Round Motor Run Capacitor - Dual 5 Round Motor Run Capacitor - Single 5 TOTALINE CAPACITOR ACCESSORIES 6 Start Kit 6 Bracket, End Cap, Boot 6 Wire Kit 6 Start Thermister 6 Strap 6 TOTALINE RELAYS 7 Relay Application Data - Control Relays 7 Fan & Power Relays 8 Two Pole Fan Relays 8 Heavy Duty Fan Relays 8 Start Relays 8 Fan Control Center Relays 8 TOTALINE CONTACTORS 9 General Information 9 TOTALINE CONTROL TRANSFORMERS 10 General Information 10 TOTALINE PROTECTION CONTROLS 10 Head Pressure Control With Optional Heat Pump Override 10 Head Pressure Control With Optional Heat Pump Override-line Voltage 11 Monitors 12 Defrost Control 13 Timers And Delays 14 Timers And Delays 16 Start Kits 16 FUSES AND ACCESSORIES 17 Fuses 17 Littelfuse Fuse Accessories 20 TOTALINE WIRING ACCESSORIES 22 Terminal Kits 22 Cable Ties - Natural Color 22 Cable Ties - Black 23 Other Wiring Accessories 24 Shrink Tubing 25 Tew Thermoplastic Equipment Wire 26 Terminals And Connectors 27 Kits And Application Tools 31 I

3 Components The following section contains information on common electrical components, including: Totaline Capacitors Totaline Capacitor and Accessories Totaline Relays Totaline Contactors Totaline Control Transformers Totaline Protection Controls Fuses and Accessories Totaline Wiring Accessories Totaline Universal HVAC/R Part and Supplies Totaline.com 1

4 TOTALINE CAPACITORS Genaral Information This capacitor series is designed specifically for the motor run applications where the capacitors are used in conjunction with permanent split capacitor type motors. They may be used on either 50 or 60-Hertz systems but should not be used at higher frequencies or in applications where higher frequency harmonics are present. For those types of applications the General Purpose AC Capacitors should be used. Features And Benefits Reliability tested to meet 60,000 service hours, per United Technologies application parameters High grade metallized Polypropylene Film (5 to 12 microns thick) RoHS Compliant UL Approved with Pressure Sensitive interrupter of 1000 AFC Performance tested per United Technologies reliability requirements for capacitance ratings, power factor, dissipation factor and high voltage testing Product Range Capacitance: 5uF to 80uF Tolerance: +/- 6% Voltage: 370 to 440 VAC Op Temp: -29o to +68o C Note: Distributors that have historically stocked 440 volt and 370 volt capacitors round and / or oval designs can standardize inventory to use a 440 volt capacitors as replacement for a 370 volt capacitor provided the capacitance in (Mfd.) stays exactly the same. Warning Note: Under no circumstances are we recommending usage of a 370 volt capacitor to replace a 440 volt capacitor. Also our capacitor straps are designed to secure and ground the capacitor, so we don t recommend mixing oval or round capacitor designs. 2 Totaline Universal HVAC/R Part and Supplies Totaline.com

5 TOTALINE CAPACITORS Oval Motor Run Capacitor - Dual Cap Grp Voltage (VAC) Capacitance (μf ) MFD Dia Height P Oval Dual 370 5/ P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P S Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P S Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P S Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / P Oval Dual / Totaline Universal HVAC/R Part and Supplies Totaline.com 3

6 TOTALINE CAPACITORS Oval Motor Run Capacitor - Single Cap Grp Voltage (VAC) Capacitance (μf ) MFD Dia Height P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P S Oval Single P Oval Single P Oval Single P S Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single P Oval Single Totaline Universal HVAC/R Part and Supplies Totaline.com

7 TOTALINE CAPACITORS Round Motor Run Capacitor - Dual Cap Grp Voltage (VAC) Capacitance (μf ) MFD Dia Height P RS Round Dual / P RS Round Dual / P R Round Dual / P RS Round Dual / P R Round Dual / P R Round Dual / P RS Round Dual / P R Round Dual / P RS Round Dual / P R Round Dual / P RS Round Dual / P RS Round Dual / P R Round Dual / P RS Round Dual / P R Round Dual / P RS Round Dual / P R Round Dual / P RS Round Dual / P RS Round Dual / P R Round Dual / P R Round Dual / P RS Round Dual / P RS Round Dual / P R Round Dual / P RS Round Dual / P RS Round Dual / P R Round Dual / P R Round Dual / P RS Round Dual / P RS Round Dual / P RS Round Dual / P RS Round Dual / P RS Round Dual / P R Round Dual / P RS Round Dual / P RS Round Dual / P RS Round Dual / P RS Round Dual / P RS Round Dual / P RS Round Dual / P RS Round Dual / P R Round Dual / P RS Round Dual / P RS Round Dual / P RS Round Dual / P RS Round Dual / P RS Round Dual / P R Round Dual / P RS Round Dual / P R Round Dual / P RS Round Dual / P R Round Dual / P RS Round Dual / P RS Round Dual / P R Round Dual / P RS Round Dual / P R Round Dual / P RS Round Dual / P RS Round Dual / P RS Round Dual / P RS Round Dual / Round Motor Run Capacitor - Single Cap Grp Voltage (VAC) Capacitance (μf ) MFD Dia Height P R Round Single P R Round Single P R Round Single P R Round Single P R Round Single P R Round Single P R Round Single P R Round Single P R Round Single P R Round Single P RS Round Single P R Round Single P R Round Single P R Round Single P R Round Single P R Round Single P R Round Single P R Round Single P RS Round Single P R Round Single P R Round Single P R Round Single P R Round Single P R Round Single P R Round Single Totaline Universal HVAC/R Part and Supplies Totaline.com 5

8 TOTALINE CAPACITOR ACCESSORIES Start Kit Totaline Start Kits are for use with PSC compressors requiring additional starting torque. Totaline Start Kits are available for the most popular Copeland, Tecumseh, Bristol, and Carlyle compressors. The Kit contains the following: Start Capacitor Start Relay Wire Kit (1) Black Wire 54 Long (1) Brown Wire 16 Long (1) Blue Wire 38 Long (1) Brown Wire 30 Long End Cap Bracket Instruction Sheet Start Capacitor Start Relay Mfd Range Volts Contact Rating Max Oper Volts Pickup Volts Dropout Volts P AMP P AMP P AMP P AMP P AMP P AMP P AMP P AMP P AMP P AMP P AMP P AMP Bracket, End Cap, Boot Wire Kit An assortment of wires to be used to connect a Start Relay and Start Capacitor to a unit for hard start capability. Description P (1) Black Wire 44 IN. Long, (1) Blue Wire 22 IN. Long, (1) Black Wire 14 IN. Long, (1) Yellow Wire 29 IN. Long P (1) Black Wire 54 IN. Long, (1) Brown Wire 16 IN. Long, (1) Blue Wire 38 IN. Long, (1) Brown Wire 30 IN. Long Start Thermister This 25 ohm PTC device provides additional starting torque for compressors. Connects in parallel to run capacitor. Part Name P Start Thermistor Strap Part Name Use With Capacitor P Mounting Strap 1.21 x 2.06 Oval P Mounting Strap 1.81 x 2.81 Oval P Mounting Strap 1.87 x 3.56 Oval P Mounting Strap 15 Fit All Part Name Use With Capacitor P Start Capacitor Bracket 3-3/8" Long P Start Capacitor Bracket 4-3/8" Long P Capacitor End Cap 1-13/16" Diameter P Capacitor End Cap 2-1/16" Diameter P Capacitor End Cap 2-9/16" Diameter P Terminal Boot Single Oval Top Outlet P Terminal Boot Single Oval (2) Side Outlets P Terminal Boot Single Round P Terminal Boot Dual Oval 6 Totaline Universal HVAC/R Part and Supplies Totaline.com

9 TOTALINE RELAYS Relay Application Data - Control Relays The main function of any relay is switching electrical circuits. Selection depends on load characteristics which should be matched closely to the rating of the relay to avoid contact point deterioration. Relay ratings in amperes are listed in this brochure as nductive or resistive. Inductive Rating - applies to switching of motors and coils for contactors and relays. Resistive Rating - applies to switching of electric resistance heating elements.the relays shown on the following pages have been classified into two major categories, power rated relays for intermediate loads and pilot duty relays for low level switching. Pilot duty relays:contacts are made of a fine silver alloy and are shaped and sized for low level current switching. The fine silver alloy contact provides a very low surface resistance for the best possible contact life. Use on higher or intermediate loads would melt the relay points causing a welded contact. Power Rated Relays:Contacts are generally made of silver cadmium oxide with a very high surface resistance. They are sized larger than pilot duty contacts to handle switching of intermediate loads during which a slight arc may occur. Due to being larger in size, they must operate with a lower unit pressure on the contacts and, for satisfactory performance, depend on the makebreak arc process to break down the resistance of deposits formed on the contacts. Use of this type relay to switch low level loads is not recommended by Carrier or its suppliers due to the lower contact pressure, the high surface resistance of the contacts and the absence of the slight arc during switching. A continuing build-up of deposits on contact points will cause a nonconductive surface and a failed relay. In some instances a power rated relay will fail to switch a pilot duty load on initial use. For reliable relay operation, it s advisable not to use a power rated relay for a pilot duty relay or vice versa. DB - Indicates contacts are Double Break type in which stationary contacts are connected by a bridging bar. Two examples of a double break arrangement are shown with contacts #1 and #2 stationary. Both are SPST, normally closed, double break arrangements. Totaline Universal HVAC/R Part and Supplies Totaline.com 7

10 TOTALINE RELAYS Fan & Power Relays General Purpose Relay Dependable, low cost solution for air conditioning and heating switching. Insulating Material - Constructed of UL recognized Class B insulating material Temperature Range to 150 Fahrenheit Single Pole Fan Relays- Similar To Type 84 Fan Relays Fan control Appliances Business Machines Photoelectric control and general purpose switching Contact Rating 125/250 Vac Description P Amps (Ind.) 16 Amps (Res.) SPST, 24 V Coil P Continuous SPST, 110 V/120 V Coil P Amps Inrush SPST, 208/240 V Coil P Amps (ind.) 8 Amps (res.) SPDT, 24 V Coil P Continuous SPDT, 110/120 V Coil P Amp Inrush SPDT, 208/240 V Coil Two Pole Fan Relays Start Relays Features: Single pole, NC relays Totally Enclosed Contacts rated for a max.arc rupturing capacity at 600 vac and under. 1/4" Quick connects G.E. 3arr3 type & rbm type 50/60 hz Volts Contact Rating Pickup Dropout Max Oper P Amp P Amp P Amp P Amp P Amp P Amp P Amp P Amp P Amp P Amp P Amp P Amp P Amp P Amp P Amp Features: Vending machines Appliances Safety control Fan control Heating Air conditioning and general purpose switching Terminals Description P Power Power 24 V Coil P Power Power 110 V/120 V Coil P Power Power 208/240 V Coil P Power Pilot 24 V Coil P Power Pilot 110 V/120 V Coil P Power Pilot 208/240 V Coil P Pilot Pilot 24 V Coil P Pilot Pilot 110 V/120 V Coil P Pilot Pilot 208/240 V Coil Heavy Duty Fan Relays Contact Arrangement Description P SPDT - NO 24 V Coil P SPDT - NO 24 V Coil P SPNO - SPNC 24 V Coil Fan Control Center Relays Features: 40 VA transformer 24 volt secondary Fits standard 4 Junction box. Self-contained unit requires no additional closure. Unit imprinted with wiring diagram Resistive contact rating: 277v Relay coil volts: 24 Inductive contact rating: 3/4 h.p., 120v; 3/4 h.p., 240v Contact Arrangement Transformer Primary Plug-In Relay P DPDT 120/208/240 Semi-Enclosed P SPNO/SPNC 120 Semi-Enclosed P SPDT 120 Semi-Enclosed P SPST 120 Semi-Enclosed P SPDT 240 Semi-Enclosed P SPDT 120 Semi-Enclosed 8 Totaline Universal HVAC/R Part and Supplies Totaline.com

11 TOTALINE CONTACTORS General Information Design Construction: 50/60 Hz Meets specifications for devices up to 600 VAC in accordance with U/L bulletin no. 508 Industrial Control Equipment Coil Insulation: Standard Class B insulation. Terminals: Power #10-32 combination hex washer head screw, #10-32 combination hex head with pressure plate or box lug for 4-14 CU/AL wire. Quick Connects - 2) male push-ons available on each pole Coil - (2) male push-ons. Covers: Standard on 40 amp and larger. Mounting Panel mount and straight thru wiring. Application: Designed for use in residential and commercial refrigeration, air conditioning, & heating applications. Also: Water pump motors Blower or fans Compressor motors Resistance heating & other similar applications. UL / CSA recognized Pole Amps Terminal Type Coil Vac Aux Contact Length In Height In P Single Pole 30 (Screw Term. & Shunt) (8.38) 2.3 (5.84) P Single Pole 30 (Screw Term. & Shunt) (8.38) 2.3 (5.84) P Single Pole 30 (Screw Term. & Shunt) 208/ (8.38) 2.3 (5.84) P Two Pole 30 (Screw Terminals) (8.38) 2.5 (6.35) P Two Pole 30 (Screw Terminals) (8.38) 2.5 (6.35) P Two Pole 30 (Screw Terminals) 208/ (8.38) 2.5 (6.35) P Two Pole 40 (Lug Terminals) (8.38) 2.6 (6.60) P Two Pole 40 (Lug Terminals) (8.38) 2.6 (6.60) P Two Pole 40 (Lug Terminals) 208/ (8.38) 2.6 (6.60)- P A Three Pole 30 (Screw Terminals) 24 P282-X (8.64) 2.6 (6.60) P A Three Pole 30 (Screw Terminals) 120 P282-X (8.64) 2.6 (6.60) P A Three Pole 30 (Screw Terminals) 208/240 P282-X (8.64) 2.6 (6.60) P A Three Pole 40 (Lug Terminals) 24 P282-X (8.64) 2.6 (6.60) P A Three Pole 40 (Lug Terminals) 120 P282-X (8.64) 2.6 (6.60) P A Three Pole 40 (Lug Terminals) 208/240 P282-X (8.64) 2.6 (6.60) P Three Pole 50 (Lug Terminals) 24 P282-X (10.67) 3.6 (9.14) P Three Pole 50 (Lug Terminals) 120 P282-X (10.67) 3.6 (9.14) P Three Pole 50 (Lug Terminals) 208/240 P282-X (10.67) 3.6 (9.14) P Three Pole 60 (Lug Terminals) 24 P282-X (10.67) 3.6 (9.14) P Three Pole 60 (Lug Terminals) 120 P282-X (10.67) 3.6 (9.14) P Three Pole 60 (Lug Terminals) 208/240 P282-X (10.67) 3.6 (9.14) P Three Pole 75 (Lug Terminals) 24 P282-X P Three Pole 75 (Lug Terminals) 120 P282-X P Three Pole 75 (Lug Terminals) 208/240 P282-X P Three Pole 90 (Lug Terminals) 24 P282-X P Three Pole 90 (Lug Terminals) 120 P282-X P Three Pole 90 (Lug Terminals) 208/240 P282-X Totaline Universal HVAC/R Part and Supplies Totaline.com 9

12 TOTALINE CONTROL TRANSFORMERS General Information Features: For low and medium VA requirements. Use to step down voltage for control circuits. Large selection of ratings and mounting. Fig VA Rating Primary Volts Hz Secondary Volts P * A /60 24 P * A /208/240 50/60 24 P * C /208/240 50/60 27/12/2.5 P * C /208/240 50/60 24 P * C / /60 12/24 P B /208/240/480 50/60 24 P B /208/240/480 50/60 24 *Supplied with 9 inch leads. TOTALINE PROTECTION CONTROLS Head Pressure Control With Optional Heat Pump Override Head Pressure Controls - Temperature sensitive fan motor control which regulates head pressure at low ambients by varying the air volume through the condenser. Its unique construction permits exceptionally quick response times to changes in liquid line temperatures. Application Ideal for low ambient conditions found in: Supermarkets - Frozen Storage Computer rooms Temperature/ Humidity Sensitive Environments FEATURES / APPLICATIONS Intregal Heat Pump Bypass circuitry allows electronic bypass of speed control during heat pump operation. Eliminates overshoots common to on/off and pressure switch controls. Helps prevent evaporator freeze-ups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions. One model covers VAC Features: hard start, low temperature cutoff, high temperature bypass, isolated 24VAC supply. Controls up to 3 refrigerant circuits. Typical application: heat pumps. Specs Input: Control: VAC Line Input: VAC Output: Triac max: 10 amps min: 100 ma Output: Range: VAC Replaces Hoffman: 800/800A/800ASA/ RANCO: E31 Series Johnson Controls: P66 ACT: FM2000 Volts Description P H VAC HPC w/optional,hp override 10 Totaline Universal HVAC/R Part and Supplies Totaline.com

13 TOTALINE PROTECTION CONTROLS Head Pressure Control With Optional Heat Pump Override P C Volts Description P C VAC HPC (Canada) Head Pressure Control With Optional Heat Pump Override-line Voltage P H, P H FEATURES / APPLICATIONS Built-in transformer eliminates cost, reduces installation time and simplifies wiring. Direct set up from line voltage. Helps prevent evaporator freezeups, low pressure cut-outs and liquid-slugged compressors in low ambient conditions. Features: hard start, low temperature cutoff, high temperature bypass, isolated 24 VAC supply is built into the control. Mechanical dimensions: 4.5 L x 3 W x 2 H. Ideal for heat pumps, line voltage, air conditioning and refrigeration SPECS Input: Frequency: 50/60 Hz Power Consumption: 4 24 VAC Output Type: Triac Output Voltage: P H: 120 or 208/240 VAC P H: 480 VAC Output Current: max: 10 amps min: 100 ma REPLACES Hoffman: 800/800A/800ASA/ RANCO: E31 Series Johnson Controls: P66 Integral transformer reduces inventory Volts Description P H 120 or 240 VAC Line Voltage,HPC w/optional,hp Override P H 480 VAC Line Voltage,HPC w/optional,hp Override *Supplied with 9 inch leads. Totaline Universal HVAC/R Part and Supplies Totaline.com 11

14 TOTALINE PROTECTION CONTROLS Monitors Three Phase Monitor Features / Application Lower cost, full performance protection. Monitors front and back sides of system VAC operation. Bright LED indicators. Identifies front and back side faults. Knob-adjustable features. Reset-auto or manual (1 trial). Built-in short cycle protection. Monitors: voltage unbalance, high/low voltage, phase loss, reversal, incorrect sequencing, rapid short cycling. Specs Input: Line Voltage: VAC Unbalance: adj. 2-25% Control: VAC Frequency: 50/60 Hz Output: Relay,SPDT n.o.: 10amps n.c.: 6 amp Replaces Diversified: AC-2020 AC-301, 302 Motorsaver: 455 SSAC: QLM/QLV TmeMark: 265 Wagoner: WPC-800 WATSCO: EAC-800, EAC-8000 Volts Control Voltage P VAC Three Phase Programmable Monitor P Features / Application Monitors front and back side of system. Programmable-25-fault memory storage. Independent high/low voltage settings for dual voltage compressor applications. Identifies front & back side faults. High temperature LCD to 167 F VAC operation Simultaneous voltage display-no scrolling. Line voltage programmable. Reset-auto or manual. Non-volatile memory. Monitors: voltage unbalance, high/low voltage, phase loss, reversal, incorrect sequencing, rapid short cycling. Does not require control voltage for operation. Specs INPUT: Voltage: VACI Frequency: 50/60 Hz Voltage Unbalance: adj. 2-25% Control: VAC OUTPUT: Relay, SPDT n.o.: 10 amps n.c.: 6 amps Replaces Diversified: AC-2020, AC-301, 302 Motorsaver: 455 SSAC: QLM / QLV TimeMArk: 265 Wagner: WPC-800 Watsco: EAC-800, EAC-8000 Volts Description P Programmable Three Phase VAC 12 Totaline Universal HVAC/R Part and Supplies Totaline.com

15 TOTALINE PROTECTION CONTROLS Monitors Three Phase Line Voltage Monitor P & P Features / Application Low cost, single side 3-phase protection Bright LED indications for faults and loads energized Easy to install, no adjustments Wide operating range: VAC Less than 1 second phase loss response Automatic reset from a fault condition Compact packaging: fits almost anywhere Rugged, epoxy-encapsulation for extreme conditions Works great with the Totaline P for load side monitoring of part winding start and multiple compressor systems. Specs Line Voltage: VAC Frequency: 50/60 Hz Control Voltage: P : VAC P : VAC Output: Relay: SPST P : N.O. 10 amps P : N.O. 30 amps Case Dimensions:3.1 x 3.2 x 1.4 h Volts Control Voltage Description P VAC Low Cost Three Phase P VAC Low Cost Three Phase Single Phase Monitor Features / Application Low cost single phase motor protection. Built-in anti-short cycle protection. Detects high/low voltage conditions. Helps prevent rapid system recycling. LED indicator: red for fault, green for normal conditions. Heavy duty SPDT, isolated relay output. 5-second interrogation delay prevents nuisance trips. Specs Input: Line: VAC Output: Relay,SPDT n.o.: 5 amps n.c.: 5 amps Time delay Range: adj sec. Replaces Diversified: CV-100-RS CV-200-RS15 CV-200-RS20 WATSCO: EAC-401 EAC-402 EAC-403 EAC-404 Defrost Control Volts Description P B VAC Single Phase Monitor Features / Application Direct replacement for OEM type 621 Low cost, time/temperature defrost. 24 VAC operation (18-30 VAC). 10 min. defrost interval. Pin-selectable interval times (30/60/90). Test pins reduce test time by 256x. HOLD input accumulates actual compressor run times. Sensor input for defrost terminate. Conformally coated. Specs VAC 50/60 Hz Output: Relay,output Form:SPDT n.o.: 2 amps Defrost: 10min. fixed Time delay Interval times: Pin selectable 30/60/90 min. Replaces Amana C ARCO Avion DFT100 Coleman 30130B3741 ICM DFOS Intertherm Janitrol B Lennox 66G950 Ranco DT Rheem/Ruud Snyder General , Weatherking Description P Vac Defrost Control Totaline Universal HVAC/R Part and Supplies Totaline.com 13

16 TOTALINE PROTECTION CONTROLS Timers And Delays Bypass Timer Designed to bypass a control or device during startup. Typically used to bypass a low pressure switch during compressor heat pump startup or to bypass an oil pressure switch upon startup. Helps to eliminate nuisance lockouts. Features / Application Designed to bypass a low pressure switch or other device during startup. Ideal for low ambient startups. Integral component for winter start kits. Helps to reduce nuisance lockouts. Universal AC voltage operation. Knob-adjustable time delays. Epoxy-encapsulated circuitry. Specs VAC 1 Amp 10 Amp inrush Knob-adjustable time Delays: 10-1,000 sec. Replaces Mars: Supco: TDP68 Description P VAC, 1 Amp Bypass Timer Post Purge Fan Delay Timers Model P Controls the circulating fan in heat pump, air conditioning and forced air systems. OFF delay timing function continues to run the fan at the end of the heating/cooling cycle, thereby purging ducts of residual air and increasing system efficiency. Features / Application Designed to bypass a low pressure switch and other device during startup Ideal for low ambient startups. Integral component for winter start kits Helps to reduce nuisance lockouts Universal AC voltage operation Knob-adjustable time delays Epoxy-encapsulated circuitry Specs Input: VAC 1 Amp, 10 Amp inrush SPST, N.O. Time Delays: fixed or adj ON: sec OFF: sec Replaces Mars: Gemline: 1C216 Description P VAC, 1 Amp, 10 Amp Inrush Model P Controls the circulating fan in heat pump, air conditioning and forced air systems. OFF delay timing function continues to run the fan at the end of the heating/cooling cycle, thereby purging ducts of residual air and increasing system efficiency. Features / Application Low cost open board design. High power, relay output. Dual function fan delay timer. Controls the circulating fan in heat pump and A/C and forced systems. OFF delay purges ducts of residual air. ON delay allows air to reach the proper comfort level prior to energizing the fan. Specs Input: VAC N.O. -20 VAC N.C VAC Time delays fixed at: ON: 1 sec. OFF: 60 sec. Replaces EMI WATSCO: AHBC-060, AHBC-090 Description P VAC, 1 Amp Post Purge Fan Delay Timer 14 Totaline Universal HVAC/R Part and Supplies Totaline.com

17 TOTALINE PROTECTION CONTROLS Timers And Delays Delay-On-Break Timer - Not Adjustable Helps to protect air conditioning, refrigeration and heat pump equipment from damage which may be caused by the rapid short-cycling of compressor. Features / Application Higher 1.5 amp power rating. Compressor lockout/anti-short cycle timer. Helps to protect compressors from damage caused by rapid short cycling Simple, 2-wire hookup. Compact 2 x 2 package. Description Specs Input: VAC 1.5 amps 15 amp inrush Voltage drop 3.5 V typical 4.5 V max P VAC, 1.5 amps, Delay-On-Break Timers Replaces Diversified: ASC-500, SC 501, SC Gemline: IC321, IC322 WATSCO: EAC-500, EAC W, EAC W Delay-On-Break Timer - Adjustable Delay Helps to protect air conditioning, refrigeration and heat pump equipment from damage which may be caused by the rapid short-cycling of compressor. Features / Application Universal voltage operation. Higher 1.5 amp power rating. Compressor lockout/anti-short cycle timer. Helps to protect compressors from damage caused by rapid short cycling. Simple, 2-wire hookup. Compact 2 x 2 package. Description Specs Input: VAC 1.5 amps 15 amp inrush Voltage drop 3.5 V typical 4.5 V max knob adjustable delays min P VAC, 1.5 amps, Delay-On-Break Timers Replaces Diversified: ASC-500, ASC 501 ASC502, ASC Gemline: IC320 WATSCO: EAC501-ADJ, EAC501-ADJ-X MARS: Robertshaw: Supco: TD-73 Delay-On-Break Timer - Fixed and Adjustable Delay Helps to protect air conditioning, refrigeration and heat pump equipment from damage which may be caused by the rapid short-cycling of compressor. Features / Application UL 873 recognition as compressor controller. Help to prevent scroll compressors from reversing. Fast response time: 16 ms. Compressor lockout/anti-short cycle timer. Prevents low voltage starts. Eliminates relay chatter due to thermostat bounce or tampering. Works with anticipator-type thermostats. Description P VAC, 1.5 amps, Delay-On-Break Timers Specs Input: VAC 1.5 amps 15 amp inrush 3 or 5 min. fixed or 10 min. adjustable time delays Replaces Gemline: IC243 MARS: & Robertshaw: , WATSCO: EAC-511, EAC , EAC , EAC , EAC-426-ADJ Totaline Universal HVAC/R Part and Supplies Totaline.com 15

18 TOTALINE PROTECTION CONTROLS Timers And Delays Delay-On-Make Timer Helps to protect air conditioning, refrigeration and heat pump equipment from damage which may be caused by the rapid short-cycling of compressor. Features / Application Universal voltage operation. Higher 1.5 amp power rating. Knob-adjustable time delays. Specs Input: VAC 1.5 amps 15 amp inrush Replaces Diversified: AC-800 fixed volt: ASC-00/601 Gemline: IC310/ICS213 Work with anticipator-type thermostats. SPST, N.O. Mars: 32391/32367 One model replaces many in field. Ideal for Adjustable delays Robertshaw: compressor staging min.( sec.) Supco: TD-68 D-69 Simple 2-wire hookup. Voltage drop: WATSCO: EAC-701-ADJ., 1.5 amps X, EAC-700-A Compact 2 x 2 package. Description P VAC, 1.5 amps, Delay-On-Break Timers Start Kits Smart Start Kits - Current Sensing By monitoring the compressor current upon start-up, the Smart Start is able to engage the hard start capacitor for precisely the correct amount of time, ensuring maximum starting torque without the risk of supplying too much current into the start winding. A timed safety circuit is provided in the event the motor fails to start within 600ms. Current sensing Hard Start precisely increases starting torque. Operates from VAC Max Input Voltage: 502 VAC Patented current sensing circuitry Self-Adjusting to voltage fluctuation Easy to install, 2 wires, clips or screws Bos starting torque Disengages upon start HP Rating Replaces P /2-3 HP Supco : SPP-8 Kickstart : TO-5 A-1 : WSX-1 P HP Kickstart : KS1 P HP -- Smart Start Kits - Voltage Sensing Products employ patented circuitry which monitors differential compressor auxiliary voltage,determines the state of the motor and precisely engages and disengages the start capacitor. Not Effected by Ambient temperature Recycles instantly (less than 1 second) Multi-voltage operation - either 115 or 230 VAC Ideally suited for: Water Coolers Vending Machines Household Refrigerators (115 or 230 VAC) Commercial Refrigeration (115 or 230 VAC) Air Conditioners and Heat Pumps Voltage Replaces Voltages MFD Oper Temp Range Max Input Voltage Range Recommended Range P VAC Supco : SPP-5 MARS : 330 capacitor C to + 65 C 390 VAC 1/12-10 HP 1/12-1 HP A-1 : WSX-5 P VAC Supco : SPP-6 MARS : A-1 : WSX capacitor C to + 65 C 390 VAC 1/12-10 HP 1/2-1 HP 16 Totaline Universal HVAC/R Part and Supplies Totaline.com

19 FUSES AND ACCESSORIES Fuses FLNR-ID TYPE - 250V ATO TYPE - 32V AC FLM TYPE - 250V Min Order Description 0ATO003.V 100 Auto Blade3 AMP 0ATO004.V 5 Auto Blade4 AMP 0ATO005.V 100 Auto Blade5 AMP ATO 7-1/2 5 Auto Blade7.5 AMP 0ATO010.V 5 Auto Blade10 AMP 0ATO015.V 5 Auto Blade15 AMP ATO20 5 Auto Blade20 AMP ATO25 5 Auto Blade25 AMP ATO30 5 Auto Blade30 AMP FLQ TYPE - 500V Min Order Description RK5 Dual Elem. FLNR035.TXID AMP FLNR040.TXID AMP FLNR045.TXID AMP FLNR050.TXID AMP FLNR060.TXID AMP FLNR 70 ID 5 70 AMP FLNR 80 ID 5 80 AMP FLNR 90 ID 5 90 AMP FLNR100.VXID AMP FLNR 200 ID AMP FLNR TYPE - 250V Min Order Description FLM 3/10 10 Midget TD 3/10 AMP 0FLM.600T 10 Midget TD 6/10 AMP FLM 1 10 Midget TD 1 AMP FLM 2 10 Midget TD 2 AMP FLM 3 10 Midget TD 3 AMP FLM 5 10 Midget TD 5 AMP 0FLM008.T 10 Midget TD 8 AMP 0FLM010.T 10 Midget TD 10 AMP 0FLM015.T 10 FUSETRON 15A 0FLM020.T 10 Midget TD 20 AMP 0FLM030.T 10 Midget TD 30 AMP 312 TYPE - 250V Min Order Description Time Delay Midget FLQ 1/2 10 1/2 AMP 0FLQ02.5T /2 A 0FLQ003.T 10 3 AMP FLQ AMP 0FLQ005.T 10 5 AMP FLQ AMP 0FLQ008.T 10 8 AMP 0FLQ010.T AMP 0FLQ015.T AMP 0FLQ020.T AMP FLQ AMP 0FLQ030.T AMP Min Order Description RK5 Dual Elem. FLNR AMP FLNR04.5T /2 AMP FLNR005.T 10 5 AMP FLNR010.T AMP FLNR015.T AMP FLNR020.T AMP FLNR025.T AMP FLNR030.T 10 30AMP FLNR035.T AMP FLNR040.T 10 40AMP FLNR045.T AMP FLNR050.T AMP FLNR060.T AMP FLNR AMP FLNR AMP FLNR100.V AMP Min Order Description AG Glass 1/10 AMP AG Glass 1/4 AMP AG Glass 1/2 AMP AG Glass 3/4 AMP AG Glass 1.5 AMP VXP 5 3AG Glass 1 AMP VXP 5 3AG Glass 2.5 AMP VXP 5 3AG Glass 2 AMP VXP 5 3AG Glass 4 AMP VXP 5 3AG Glass 5 AMP VXP 5 3AG Glass 6 AMP VXP 5 3AG Glass 7 AMP VXP 5 3AG Glass 8 AMP VXP 5 3AG Glass 10 AMP Totaline Universal HVAC/R Part and Supplies Totaline.com 17

20 FUSES AND ACCESSORIES Fuses 314 TYPE - 250V 312 TYPE - 32V Min Order Description AG Glass 12 AMP VXP 5 3AG Glass 15 AMP VXP 5 3AG Glass 20 AMP VXP 5 3AG Glass 25 AMP AG Glass 30 AMP Min Order Description AB Ceramic 1 AMP AB Ceramic 2 AMP VXP 5 3AB Ceramic 3 AMP VXP 5 3AB Ceramic 4 AMP VXP 5 3AB Ceramic 5 AMP VXP 5 3AB Ceramic 6 AMP VXP 5 3AB Ceramic 8 AMP VXP 5 3AB Ceramic 10 AMP VXP 5 3AB Ceramic 15 AMP VXP 5 3AB Ceramic 20 AMP 313 TYPE - 250V 362 TYPE - 250V 313 TYPE - 32V Min Order Description 3AG Glass AG Glass 1/10 AMP VXP 5 3AG Glass 1/8 AMP AG Glass 2/10 AMP AG Glass 1/4 AMP AG Glass 4/10 AMP AG Glass 6/10 AMP AG Glass 7/10 AMP AG Glass 3/4 AMP VXP 5 3AG Glass 1 AMP VXP 5 3AG Glass 1.5 AMP VXP 5 3AG Glass 2.5 AMP AG Glass 2 AMP VXP 5 3AG Glass 3 AMP AG Glass 4 AMP VXP 5 3AG Glass 5 AMP AG Glass 7 AMP AG Glass 8 AMP Min Order Description VXIDP 5 3AG Glass 10 AMP AG Glass 15 AMP Min Order Description AG Glass 1/8 AMP AG Glass 3/16 AMP AG Glass 1/4 AMP V 5 8AG Glass 1/2 AMP MDA2 5 8AG Glass 1 AMP V 5 8AG Glass 2.5 AMP V 5 8AG Glass 3 AMP FLSR-ID TYPE - 600V Min Order Description RK5 Dual Elem. FLSR 10 ID AMP FLSR015.TXID AMP FLSR020.TXID AMP FLSR025.TXID AMP FLSR030.TXID AMP FLSR035.TXID AMP FLSR040.TXID AMP FLSR045.TXID AMP FLSR050.TXID AMP FLSR060.TXID AMP FLSR070.VXID 5 70 AMP FLSR080.VXID 5 80 AMP FLSR090.VXID 5 90 AMP 18 Totaline Universal HVAC/R Part and Supplies Totaline.com

21 FUSES AND ACCESSORIES Fuses FLSR TYPE - 600V Min Order Description RK5 Dual Element FLSR010.T AMP FLSR015.T AMP FLSR020.T AMP FLSR025.T AMP FLSR030.T AMP FLSR035.T AMP FLSR040.T AMP FLSR AMP FLSR050.T AMP FLSR060.T AMP FLSR070.V 5 70 AMP FLSR AMP FLSR AMP JLLS TYPE - 600V AC Min Order Description JLLS015.T AMP JLLS025.T AMP JLLS030.T AMP JLLS035.T AMP JLLS050.T AMP JLLS060.T AMP KLK TYPE - 600V Min Order Description 0KLK.300T 10 Midget 3/10 AMP KLK 1/2 10 Midget 1/2 AMP KLK 1 10 Midget 1 AM. 0KLK01.5T 10 Midget 1-1/2 AMP KLK 2 10 Midget 2 AMP 0KLK02.5T 10 Midget 2-1/2 AMP 0KLK003.T 10 Midget 3 AMP 0KLK03.5T 10 Midget 3-1/2 AMP 0KLK004.T 10 Midget 4 AMP 0KLK005.T 10 Midget 5 AMP 0KLK007.T 10 Midget 7 AMP 0KLK008.T 10 Midget 8 AMP 0KLK010.T 10 Midget 10 AMP 0KLK020.T 10 Midget 20 AMP KLK Midget 25 AMP 0KLK030.T 10 Midget 30 AMP KLKR TYPE V Min Order Description KLKR 1-1/2 10 Midget 1-1/2 AMP KLKR002.T 10 Midget 2 AMP KLKR 3-1/2 10 Midget 3-1/2 AMP KLKR 5 10 Midget 2 AMP KLKR006.T 10 Midget 3-1/2 AMP KLKR010.T 10 Midget 4 AMP KLKR015.T 10 Midget 5 AMP KLKR020.T 10 Midget 6 AMP KLKR030.T 10 Midget 10 AMP KLDR TYPE - 600V Min Order Descriptionn UL Glass KLDR.250T 10 1/4A KLDR.500T 10 1/2A KLDR A KLDR 1-1/ A KLDR002.T 10 2A KLDR02.5T A KLDR003.T 10 3A KLDR03.5T A KLDR A KLDR005.T 10 5A KLDR008.T 10 8A KLDR010.T 10 10A LGR TYPE - 300V NLN TYPE - 250V Min Order Description Knob Assm 0LGR003.V 5 3 AMP 0LGR004.V 5 4 AMP LGR AMP Min Order Description UL Class K5 0NLN010.T AMP NLN AMP NLN AMP NLN AMP 0NLN060.T AMP Totaline Universal HVAC/R Part and Supplies Totaline.com 19

22 FUSES AND ACCESSORIES Fuses SLC TYPE - 600V Min Order Description Class G Medium TD 0SLC002.T 10 2 AMP 0SLC003.T 10 3 AMP 0SLC005.T 10 5 AMP 0SLC006.T 10 6 AMP SLC AMP 0SLC010.T AMP 0SLC015.T AMP 0SLC020.T AMP TOO TYPE Min Order Description Dual Element TD TOO AMP TOO AMP 0TOO015.Z 4 15 AMP 0TOO020.Z 4 20 AMP TOO AMP 0TOO030.Z 4 30 AMP TOO 3-1/ /2 AMP TOO AMP TOO 6-1/ /4 AMP Littelfuse Fuse Accessories SLC TYPE - 480V SLO TYPE Min Order Description Class G Medium TD 0SLC025.T AMP 0SLC030.T AMP 0SLC035.T AMP 0SLC040.T AMP Min Order Description Medium Time Delay 0SLO015.Z 4 15 AMP SOO TYPE Min Order Description Dual Element TD 0SOO010.Z 4 10 AMP SOO 1-1/ /4 AMP 0SOO012.Z 4 12 AMP 0SOO015.Z 4 15 AMP 0SOO020.Z 4 20 AMP SOO AMP SOO AMP 0SOO6.25Z 4 6 1/4 A SOO AMP TLO TYPE Min Order Description Medium Time Delay TLO AMP TLO AMP TLO AMP Panel Mounted Fuse Holders Standard For 1-13/32" - 1-1/2" Diameter Midget And Class CC Fuses Fuse Length Range For Use With CCL 1-1/2" Class CC Fuses Standard For 13/32" Diameter Midget And Class CC Fuses Fuse Length Range For Use With /16-1-3/8 Midget Fuses /32-1-1/2 Midget Fuses Standard For 3AG 1-1/4" x 1/4" Fuses With Low Profile Fingertip Knob AMPS VOLTS 03453LF8X In-Line Fuse Holders Model U For Type Sfe Fuses Unassembled: For Assembly to #14 AWG Wire U *Comes with GLQ 10A fuse. **Comes with GMQ 3-1/2A fuse. Model ZXA For Fuse 1/4 in. x 1-1/4 in. 20A ASSEMBLED: Includes SFE 20 and 19 LOOP of #14 AWG Red Vinyl Insulated Wire Fuse Installed ZXA SFE Totaline Universal HVAC/R Part and Supplies Totaline.com

23 FUSES AND ACCESSORIES Littelfuse Fuse Accessories Midget Fuse Blocks 3 Poles Pressure plate/q.c. terminals Max wire size of #10 CU Rated for 30 Amperes,600 Volts (Amperage Range: 2/10 60) Amperage Range: L60030M-3PQ 2/10 60 Fuse Pullers Midget Fuse Pullers For use with 3/16 to 1/2" diameter Fuses. MFP Pocket Fuse Puller Description Midget Fuse Puller For use with: A 250V A 600V (9/ /32 diameter Fuses) LPFP Description Pocket Fuse Puller Box Cover Units For Plug Fuses Class T Fuse Blocks Features To Be Mounted On LSRU One Edison-Base Fuse Holder & 2-1/4 in.handy Box Grounding Receptacle LSSU One Edison-Base Fuse Holder & Single 2-1/4 in. Handy Box Pole Switch LSSY* One Edison-Base Fuse Holder & Single Pole Switch 4 in. Square Box * Do not use on DC. Universal In-Line Fuseholder Supplied with 15 loop of #14 AWG wire and 3 springs to accommodate SFE sized fuses Z 3 AG Omni Blok For use with JLLS (600 V) type fuses 3 Poles Box lug connector type Max wire size of #2 CU-AL Molded base type fuse block 1 Pole NEMA Style 1/4" Q.C. terminal Anti-rotation boss Rated for 30 A, 300 V BL Description Class H Fuse Blocks Amp rating LT600303CR 30 LT600603CR V, 3 Ag Omni Blok For use with NLN (600 V) Type uses 3 Poles Heavy Duty In-line Fuseholder For ATO Fuses Use with ATO 25 and 30 amp fuses. Supplied with two 4 wire leads of 12 gauge orange wire. Description FHA 2 Heavy Duty In-line Fuseholder Amp rating Connecror Type Max Wire LH S 30 SCREW #10 CU LH S 60 SCREW #10 CU LH C 30 BOX LUG #2 CU-AL Totaline Universal HVAC/R Part and Supplies Totaline.com 21

24 TOTALINE WIRING ACCESSORIES Terminal Kits Terminal & Tool Organizer A 21 compartment, metal box with a sturdy plastic tray insert and a metal latch. This Terminal Kit Box provides organized storage for solder less terminals, connectors and your crimping tool. The lid features a matrix chart for part number identification. Color Description P298-TKBOX Black 13.5 x 9.5 x 2 Terminal Kit Box HVAC Repair Kit TOTALINE HVAC Repair Kit contains 400 of the most popular terminals & connectors as well as a crimping tool for the AWG wire ranges. The terminals are stored in a metal terminal box with a sturdy plastic 21 compartment insert and a metal latch for securing the lid. TOTALINE graphics appear on the label set, with a matrix chart on the inside lid describing the parts, including illustrations and individual TOTALINE re-order part numbers. Color Description P298-HVACKIT Black x 9 x 2.25 AC Repair Kit Cable Ties - Natural Color Standard Ties Minimum Tensile Unlocking Strength Versatile, multiple purpose Extra Strong For Move Demanding Application Maximum Bundle Diameter Width Length Qty/Pkg P298-TF3 18 lbs. (8.2 kg) 7/8 (22.2 mm).095 (2.4 mm) 4.1 (10.4 cm) 100 P298-TF3B 18 lbs. (8.2 kg) 7/8 (22.2 mm).095 (2.4 mm) 4.1 (10.4 cm) 1000 P298-TF4 40 lbs. (18.1 kg) 1-7/16 (36.5 mm).140 (3.5 mm) 5.8 (14.8 cm) 100 P298-TF4B 40 lbs. (18.1 kg) 1-7/16 (36.5 mm).140 (3.5 mm) 5.8 (14.8 cm) 1000 P298-TF5 50 lbs. (22.7 kg) 1-7/8 (47.6 mm).180 (4.5 mm) 7.5 (19.2 cm) 100 P298-TF5B 50 lbs. (22.7 kg) 1-7/8 (47.6 mm).180 (4.5 mm) 7.5 (19.2 cm) 1000 P298-TF6 50 lbs. (22.7 kg) 3-1/16 (77.7 mm).180 (4.5 mm) 11.3 (28.5 cm) 50 P298-TF6B 50 lbs. (22.7 kg) 3-1/16 (77.7 mm).180 (4.5 mm) 11.3 (28.5 cm) 1000 P298-TF8 50 lbs. (22.7 kg) 4-1/8 (104.7 mm).180 (4.5 mm) 14.5 (36.9 cm) 50 P298-TF8B 50 lbs. (22.7 kg) 4-1/8 (104.7 mm).180 (4.5 mm) 14.5 (36.9 cm) 1000 Heavy Duty Ties Minimum Tensile Unlocking Maximum Bundle Diameter Width Length Qty/Pkg Strength P298-TF7 120 lbs. (54.4 kg) 4-1/16 (103.1 mm).300 (7.6 mm) 15 (38.3 cm) 25 P298-TF7B 120 lbs. (54.4 kg) 4-1/16 (103.1 mm).300 (7.6 mm) 15 (38.3 cm) Totaline Universal HVAC/R Part and Supplies Totaline.com

25 TOTALINE WIRING ACCESSORIES Cable Ties - Natural Color Heavy Duty Duct Straps For use with flexible air ducts and air connectors Minimum Tensile Unlocking Maximum Bundle Diameter Width Length Qty/Pkg Strength P298-TF lbs. (79.3 kg) 11 (279.4 mm).340 (8.6 mm) 37.3 (94.6 cm) 25 P298-TF lbs. (79.3 kg) 14.5 (368.3mm).340 (8.6 mm) 48.5 (123.1 cm) 25 P298-TF lbs. (79.3 kg) 14.5 (368.3mm).340 (8.6 mm) 48.5 (123.1 cm) (Gray)25 Mounting Cable Ties One Piece Minimum Tensile Unlocking Maximum Bundle Diameter Width Length Qty/Pkg Strength P298-TF3H 30 lbs. (13.6 kg) 1-1/4 (31.7 mm).138 (3.5 mm) 5.8 (14.9 cm) 100 P298-TF3HB 30 lbs. (13.6 kg) 1-1/4 (31.7 mm).138 (3.5 mm) 5.8 (14.9 cm) 1000 P298-TF5H 50 lbs. (22.7 kg) 1-3/4 (44.4 mm).177 (4.4 mm) 8.0 (20.3 cm) 50 P298-TF5HB 50 lbs. (22.7 kg) 1-3/4 (44.4 mm).177 (4.4 mm) 8.0 (20.3 cm) 1000 P298-TF7H 120 lbs. (54.4 kg) 4-1/16 (103.1 mm).298 (7.5 mm) 15.7 (39.8 cm 50 P298-TF7HB 120 lbs. (54.4 kg) 4-1/16 (103.1 mm).298 (7.5 mm) 15.7 (39.8 cm 500 Cable Ties - Black Standard Ties Minimum Tensile Unlocking Strength Versatile, multiple purpose Maximum Bundle Diameter Width Length Qty/Pkg P298-TF3X 18 lbs. (8.2 kg) 7/8 (22.2 mm).095 (2.4 mm) 4.1 (10.4 cm) 100 P298-TF3XB 18 lbs. (8.2 kg) 7/8 (22.2 mm).095 (2.4 mm) 4.1 (10.4 cm) 1000 P298-TF4X 40 lbs. (18.1 kg) 1-7/16 (36.5 mm).140 (3.5 mm) 5.8 (14.8 cm) 100 P298-TF4XB 40 lbs. (18.1 kg) 1-7/16 (36.5 mm).140 (3.5 mm) 5.8 (14.8 cm) 1000 P298-TF5X 50 lbs. (22.7 kg) 1-7/8 (47.6 mm).180 (4.5 mm) 7.5 (19.2 cm) 100 P298-TF5XB 50 lbs. (22.7 kg) 1-7/8 (47.6 mm).180 (4.5 mm) 7.5 (19.2 cm) 1000 P298-TF6X 50 lbs. (22.7 kg) 3-1/16 (77.7 mm).180 (4.5 mm) 11.3 (28.5 cm) 50 P298-TF6XB 50 lbs. (22.7 kg) 3-1/16 (77.7 mm).180 (4.5 mm) 11.3 (28.5 cm) 1000 P298-TF8X 50 lbs. (22.7 kg) 4-1/8 (104.7 mm).180 (4.5 mm) 14.5 (36.9 cm) 50 P298-TF8XB 50 lbs. (22.7 kg) 4-1/8 (104.7 mm).180 (4.5 mm) 14.5 (36.9 cm) 1000 Heavy Duty Ties For use with flexible air ducts and air connectors Minimum Tensile Unlocking Maximum Bundle Diameter Width Length Qty/Pkg Strength P298-TF7X 120 lbs. (54.4 kg) 4-1/16 (103.1 mm).300 (7.6 mm) 15 (38.3 cm) 25 P298-TF7XB 120 lbs. (54.4 kg) 4-1/16 (103.1 mm).300 (7.6 mm) 15 (38.3 cm) 500 Totaline Universal HVAC/R Part and Supplies Totaline.com 23

26 2015 TOTALINE HVAC/R PARTS CATALOG COMPRESSORS UTC, Business-Industrial-Systems (BIS) Carrier Corporation Printed in the U.S.A. Edition Date: 02/2015

27 TOTALINE WIRING ACCESSORIES Terminals And Connectors Closed End Connectors - Nylon Insulated Compressor Terminal Wire Range-AWG Qty/Pkg P298-CES ( ) 50 P298-CES ( ) 40 Tab Width In (mm) Wire Range AWG Qty/Pkg (mm2) P298-COM (6.35) 12-8 ( ) 20 Twist-On Wire Connectors Self-Stripping Tap Connectors Wire Range AWG (mm2) Qty/Pkg P298-SSTCR ( ) Red 25 P298-SSTCB ( ) Blue 25 P298-SSTCY ( ) Yellow 20 Compressor Hook-up Lead Kit UL Listed/CSA Approved 221 F/105 C (Available in Blister Boxes, TOTALINE Boxes or Bulk Packs) AWG (mm2) Color/Voltage Qty/Pkg P298-WC/GREY ( ) Min. 2 # 22 Grey 100 (Blister Box) P298-WC/GREY/M ( ) Max. 2 # Volt 1,000 (Bulk Pack) P ( ) Min. 2 #18 Blue 100 (Blister Box) P298-29B ( ) Max. 3 # Volt 100 (Totaline Box) P298-WC/BLUE/M ( ) ,000 (Bulk Pack) P ( ) Min. 2 #18 Orange 75 (Blister Box) P298-31B ( ) Max. 2 # Volt 100 (Totaline Box) P298-WC/ORANGE/D ( ) (Bulk Pack) P ( ) Min. 3 #18 Yellow P298-33B ( ) Max. 4 # Volt 100 (Totaline Box) and 1 #18 P298-WC/YELLOW/D ( ) (Bulk Pack) P ( ) Min. 2 #14 Red 35 (Blister Box) P298-35B 18-8 ( ) Max. 4 # VOLT 100 (Totaline Box) P298-WC/RED/D 18-8 ( ) (Bulk Pack) Tab Width In (mm) Wire Range AWG (mm2) Qty/Pkg P298-LEADS (6.35) 10 (6.0) 3-8 Leads With Flags 3- Heat Shrinkable Butt Connectors Totaline Universal HVAC/R Part and Supplies Totaline.com 27

28 TOTALINE WIRING ACCESSORIES Terminals And Connectors Ring Terminals Vinyl Insulated P298-YS ( ) Yellow # P298-YS ( ) Yellow # P298-YS ( ) Yellow # Butt Connectors Wire Range AWG (mm2) In / Ga (mm) Qty/Pkg P298-RR ( ) Red # P298-RR ( ) Red # P298-RR ( ) Red # P298-RR ( ) Red 1/ P298-RR ( ) Red 3/ P298-BR ( ) Blue # P298-BR ( ) Blue # P298-BR ( ) Blue # P298-BR ( ) Blue 1/ P298-BR ( ) Blue 5/ P298-BR ( ) Blue 3/ P298-YR ( ) Yellow # P298-YR ( ) Yellow # P298-YR ( ) Yellow # P298-YR ( ) Yellow 1/ P298-YR ( ) Yellow 5/ P298-YR ( ) Yellow 3/ P298-YR ( ) Yellow 1/ Heavy Duty Ring Terminals Vinyl Insulated Wire Range Awg (mm2) In / Ga (mm) Qty/Pkg P298-8R (8.0) Red 1/ P298-8R (8.0) Red 5/ P298-8R (8.0) Red 3/ P298-8R (8.0) Red 1/ P298-6R (14.0) Blue 1/ P298-6R (14.0) Blue 5/ P298-6R (14.0) Blue 3/ P298-6R (14.0) Blue 1/ Block Spade Terminals Vinyl Insulated Vinyl Insulated Wire Range Awg (mm2) Qty/Pkg P298-RBS ( ) Red 100 P298-BBS ( ) Blue 100 P298-YBS ( ) Yellow 75 Heat Shrinkable Butt Connectors Environmentally Sealed Wire Range Awg (mm2) Qty/Pkg P298-HSRBS ( ) Red 10 P298-HSBBS ( ) Blue 10 P298-HSYBS ( ) Yellow 8 Double Male-Female Adapters Tab Width In (mm) Qty/Pkg P (6.35) (Piggyback) 30 P298-7MMF (4.75) (Flat) 40 P298-7MMF (6.35) (Flat) 40 Multi-Stack Disconnects Wire Range Awg (mm2) In / Ga (mm) Qty/Pkg P298-RS ( ) Red # P298-RS ( ) Red # P298-RS ( ) Red # P298-BS ( ) Blue # P298-BS ( ) Blue # P298-BS ( ) Blue # Vinyl Insulated Tab Width In (mm) Wire Range Awg (mm2) Qty/Pkg P298-RQDFM.250 (6.35) ( ) Red 30 P298-BQDFM.250 (6.35) ( ) Blue Totaline Universal HVAC/R Part and Supplies Totaline.com

29 TOTALINE WIRING ACCESSORIES Terminals And Connectors P298-HTYR ( ) # P298-HTYR ( ) # P298-HTYR ( ) 1/ Double Male Quick Disconnects High Temperature Butt Connectors Vinyl Insulated Tab Width In (mm) Qty/Pkg P298-DMD (6.35) 10 Female Flag Quick Disconnects Uninsulated Wire Range AWG (mm2) Qty/Pkg P298-HTRBS ( ) 100 P298-HTBBS ( ) 100 P298-HTYBS ( ) 75 High Temperature Female Quick Disconnect Tab Width In (mm) Wire Range AWG (mm2) Qty/Pkg P298-RF (4.75) ( ) 50 P298-RF (6.35) ( ) 50 P298-BF (4.75) ( ) 50 P298-BF (6.35) ( ) 50 P298-YF (6.35) ( ) 40 Fully Insulated Nylon Vinyl Insulated Wire Range AWG (mm2) In / Ga (mm) Qty/Pkg P298-HTBQDF ( ) Quick Disconnect Terminals Female Tab Width In (mm) Wire Range AWG (mm2) Qty/Pkg P298-RFFI (4.75) ( ) 30 P298-RFFI (6.35) Red 30 P298-BFFI (4.75) ( ) 30 P298-BFFI (6.35) Blue 30 High Temperature Ring Terminals 900ºF / 482ºC Continuous Temperature Rating. Steel Construction. Nickel Plating Wire Range AWG (mm2) In / Ga (mm) Qty/Pkg P298-HTRR ( ) # P298-HTRR ( ) # P298-HTBR ( ) # P298-HTBR ( ) # P298-HTBR ( ) 1/ Vinyl Insulated Female Tab Width In (mm) Wire Range AWG (mm2) Qty/Pkg P298-RQDF (2.79) ( ) Red 100 P298-RQDF (4.75) ( ) Red 100 P298-RQDF (6.35) ( ) Red 100 P298-BQDF (2.79) ( ) Blue 100 P298-BQDF (4.75) ( ) Blue 100 P298-BQDF (6.35) ( ) Blue 100 P298-YQDF (6.35) ( ) Yellow 75 Totaline Universal HVAC/R Part and Supplies Totaline.com 29

30 TOTALINE WIRING ACCESSORIES Terminals And Connectors High Temperature Female Flag Disconnect Quick Disconnect Terminals Male Vinyl Insulated Male Wire Range AWG (mm2) In / Ga (mm) Qty/Pkg P298-HTBFF ( ) High Temperature Male Quick Disconnect Tab Width In (mm) Wire Range AWG (mm2) Qty/Pkg P298-RQDM (4.75) ( ) Red 100 P298-RQDM (6.35) ( ) Red 100 P298-BQDM (4.75) ( ) Blue 100 P298-BQDM (6.35) ( ) Blue 100 P298-YQDM (6.35) ( ) Yellow 75 Wire Range AWG (mm2) In / Ga (mm) Qty/Pkg P298-HTBQDM ( ) Mating Fully Insulated Quick Disconnects Female Mating Fully Insulated Quick Disconnects Nylon Insulated Male Nylon Insulated Female Tab Width In (mm) Wire Range AWG (mm2) Qty/Pkg P298-RQDFFI (4.75) ( ) Red 40 P298-RQDFFI (6.35) ( ) Red 40 P298-BQDFFI (4.75) ( ) Blue 40 P298-BQDFFI (6.35) ( ) Blue 40 P298-YQDFFI (6.35) ( ) Yellow 30 Tab Width In (mm) Wire Range AWG (mm2) Qty/Pkg P298-RQDMFI (4.75) ( ) Red 40 P298-RQDMFI (6.35) ( ) Red 40 P298-BQDMFI (4.75) ( ) Blue 40 P298-BQDMFI (6.35) ( ) Blue 40 P298-YQDMFI (6.35) ( ) Yellow 30 Snap Plugs High Temperature Spade Terminals Wire Range AWG (mm2) In / Ga (mm) Qty/Pkg P298-HTRS ( ) # P298-HTBS ( ) # P298-HTYS ( ) # Vinyl Insulated Wire Range AWG (mm2) in (mm) Qty/Pkg P298-RBM ( ) Red P298-RBM ( ) Red P298-BBM ( ) Blue P298-BBM ( ) Blue P298-YBM ( ) Yellow P298-YBM ( ) Yellow Totaline Universal HVAC/R Part and Supplies Totaline.com

31 TOTALINE WIRING ACCESSORIES Terminals And Connectors Ratchet Action Crimp Tool Kit With 4 Interchangeable Dies Snap Plug Receptacles Wire Range AWG (mm2) in (mm) Qty/Pkg P298-RBFFI ( ) Red P298-RBFFI ( ) Red P298-BBFFI ( ) Blue P298-BBFFI ( ) Blue P298-YBFFI ( ) Yellow P298-YBFFI ( ) Yellow Double Female Snap Plug Receptacles This kit was designed for the professional that insists a high quality commercial grade full cycle crimp tool. System integrity is maintained when components are terminated with this tool. An ergonomic progressive pivoting design provides maximum crimping force with reasonable hand pressure. The ratcheted design eliminates variability from crimp to crimp.this kit includes four interchangeable dies to crimp a variety of solderless terminals. Crimp Die A for AWG (.33 mm2 to 5.26 mm2) insulated Terminals Crimp Die C for AWG (.33 mm2 to 5.26 mm2) insulated Quick Disconnected Terninals Crimp Die 22-18/8 for 22-8 AWG (.33 mm2 to 8.36 mm2) uninsulated and high temperature Terminals Crimp Die F for AWG (.33 mm2 to 2.08 mm2) fully insulated flag Terminals Dia.in (mm) Qty/Pkg P298-DBR P298-DBR Kits And Application Tools Description P Ratchet Action Crimp Tool Kit With 4 Interchangeable Dies Repair and Maintenance of HVAC/R Electronic Wiring Twist on Wire Connector Kit AWG P298-TWISTONKIT This six section kit is a convenient way to store the complete assortment of color coded twist on connectors and cable ties used daily by HVC/R technicians. Fixed square spring in the connector provides a more secure grip on conductors. CSA and UL approved. Description 22-8 AWG (.33 mm2 to 8.36 mm2) 375 pieces Solderless Terminal Kit AWG An economical 18 compartment, plastic kit box contains 450 of the most popular TOTALINE solderless terminals and connectors. TOTALINE graphics appear on the label set, with a matrix chart on the inside lid describing the parts, illustrations & individual TOTALINE re-order part numbers. This kit was designed as a sales tool for branch sales counters. The kit comes with three totaline application tool as well as solderless Terminals and 5 lengths of wire. Contractors at the sales counters can physically crimp a terminal on a wire or strip a wire to withness firsthand the quality of these tools. The kit includes: P298-WS Heavy Duty wire Striper & Cutter P298-RACT Ratchet Action Crimp Tool for AWG insulated Terminals P298-RACTF Ratchet Action Crimp Tool for AWG insulated Flag Terminals P298-DEMOKIT Description Application Tool Kit for the Repair and Maintenance of HVAC/R Electronic Wiring P298-TERMKIT450 Description AWG (.33 mm2 to 5.26 mm2) 450 pieces Totaline Universal HVAC/R Part and Supplies Totaline.com 31

32 TOTALINE WIRING ACCESSORIES Kits And Application Tools Heavy Duty Tension Tool for installing Duct Straps P298-CT300 Description Features: 120 lb to 175 lb duct straps Manual tension control Neatly cuts off straps Metal construction Packaged individual box Manual Cut Off Heavy Duty Tension Tool For lb Ties Crimping & Stripping Tool AWG (.33 mm2 to mm2) This economical crimp tool crimps AWG (.33 mm2 to 3.08 mm2 ) insulated and uninsulated terminals. It strips 22-8 AWG (.33 mm2 to 8.36 mm2) soild or stranded wire; cuts and rethreads five common sizes of bolts. Adjustable machined nut and bolt for precise pivoting. Made from heat treated tool steel with cushioned grip handles. A P298-CT Heavy Duty Wire Stripper Cutter & Crimping Tool AWG (.204 mm2 to 5.26 mm2) Crimps insulated and uninsulated AWG(.33 mm2 to 5.26 mm2) terminals strips AWG (.204mm2 to 5.26 mm2) wire includes built in cutter adjustable stopper enables user to pre to pre-determine the required strip length and can be swiveled if user does not require this function. P298-WS Description AWG (.204 mm2 to 5.26 mm2) Ratchet Action Crimp Tool for Insulated and Insulated Flag Terminals Ratcheted design eliminates variability from crimp to crimp. System integrity is maintained when components are terminated with this tool. P298-RACT P298-RACTF Description AWG (.32 mm2 to 5.26 mm2) AWG (.32 mm2 to 2.08 mm2) 32 Totaline Universal HVAC/R Part and Supplies Totaline.com

33 2015 TOTALINE HVAC/R PARTS CATALOG MOTORS & ACCESSORIES UTC, Business-Industrial-Systems (BIS) Carrier Corporation Printed in the U.S.A. Edition Date: 02/2015

34 Table of Contents Categorized Listing Oils & Chemicals 1 TOTALINE OILS 1 Copeland Scroll Oil 1 Bristol R-410A Compressor oil 1 Solest 170 Polyol Ester Oil 1 Mineral Refrigeration Oils 1 Vacuum Pump Oil 1 Polyol-Ester Oils 1 Alkylbenzene Refrigeration Oils 1 Totaline Oils Reference for Carlyle and Totaline Compressors 2 TOTALINE CHEMICALS 3 Chemicals - Coil Cleaners 3 Chemicals - Other Cleaners 4 Chemicals - Protectors, Inhibitors and Sanitizers 5 Other Chemicals 6 Totaline Chemical Accessories 6 Touch-Up Paint 9 I

35 TOTALINE OILS Copeland Scroll Oil These oils were specified by Copeland for the first generation scrolls in late 1990s. Type Duty P QT EAL 22 CC Refrigeration P GAL 3 MA POE A/C P QT 3 MA POE A/C Bristol R-410A Compressor oil Type Duty P OZ CAN 32 BC A/C Solest 170 Polyol Ester Oil Type Description SOLEST170-1G 1 GAL POE Solest 170 Polyol Ester Oil SOLEST170-5G 5 GAL POE Solest 170 Polyol Ester Oil Mineral Refrigeration Oils This is a refined oil used specifically for air conditioning and refrigeration. The low moisture content means less failure. A non-foaming, waxfree oil to prevent plugged capillaries and sticking expansion valves. OEM approved by most manufacturers. Viscosity P GAL (3.8 liters) 150 P GAL (18.9 liters) 150 P QT (.95 liters) 150 P GAL (208.2 liters) 150 P GAL (3.8 liters) 300 P GAL (18.9 liters) 300 P GAL (208.2 liters) 300 P GAL (3.8 liters) 500 P GAL (18.9 liters) 500 P GAL (208.2 liters) 500 Vacuum Pump Oil A highly purified purpose vacuum pump oil that cleans and lubricates. The quart bottle (9.5 liters) has a convenient flip-top-cap. P QT (.95 liters) P GAL (3.8 liters P GAL (18.9 liters) P GAL (208.2 liters) Polyol-Ester Oils These environmentally friendly products are specifically formulated to use with the non- CFC refrigerant R-134a. The base fluids have been engineered to be totally miscible with R134a over a very wide temperature range while maintaining excellent lubricating properties. P GAL (3.8 liters) P GAL (18.9 liters) P QT (.95 liters) P GAL (3.8 liters) P QT (.95 liters) P GAL (3.8 liters P GAL (18.9 liters) P QT (,95 liters) P GAL (3.8 liters) P GAL (18.9 liters) P QT (.95 liters) P GAL (3.8 liters) P GAL (18.9 liters) P OZ Alkylbenzene Refrigeration Oils The Z-Series are high quality synthetic Alkylbenzene Refrigeration fluids for us with HCFC, CFC and ammonia refrigerants in refrigeration and air conditioning applications. Due to superior miscibility, Totaline Z-Series lubricants are excellent for systems utilizing environmentally sound refrigerants MP39, MP60, HP80 or HP81. Totaline Z-Series are superior products for all R-22, R-123 and R- 502 Systems, particularly at low temperatures. Z-200CX is formulated with a unique additive package providing extreme pressure (EP) lubricity and foam control at operating conditions. P QT (.95 liters) P GAL (3.8 liters) P GAL (18.9 liters) P QT (.95 liters) P GAL (3.8 liters) P GAL (18.9 liters) P QT (.95 liters) P GAL (3.8 liters P GAL (18.9 liters) Oils & Chemicals Totaline Universal HVAC/R Part and Supplies Totaline.com 1

36 TOTALINE OILS Totaline Oils Reference for Carlyle and Totaline Compressors Oils & Chemicals COMPRESSOR MODEL REFRIGERANT R-12, R-22 (L & H TEMP.) REFRIGERANT R-507, R-404A (MED. TEMP) REFRIGERANT R-507, R-404A (LOW. TEMP) REFRIGERANT R-134AH (M & H TEMP) TOTALINE TOTALINE TOTALINE TOTALINE OIL MODEL PART NO. OIL MODEL PART NO. OIL MODEL PART NO. OIL MODEL PART NO. Z-150 P SW68 P E68 (Do not use P SW68 P P P SW-68 for P P Carlyle 06D, E semihermetic P P Low P P Temp) RO 15 P P P Z-150 P SW68 P E68 (Do not use P SW 68 P P P SW-68 for P P Carlyle 5F/H open P P Low P P Temp) RO 15 P P P P P P P Carlyle 05T/06T E-100 P P903- E-100 Solest P P903- E-100 P P903- E-100 Solest P Screw (74) Solest Solest P Carlyle 06N Screw P SW-220 (R- (104 mm Global N/A N/A N/A N/A N/A N/A P a Only) Chiller) P P Mobil Arctic Millennium Scroll P Model now Technologies Z-150 P N/A N/A N/A N/A obsolete FLUID ANALYSIS Totaline s Fluid Analysis Service is a cost-effective method of assessing the condition of internal fluids used in all types of HVAC & R equipment and system applications. Sample Kits include the supplies needed to sample, store and ship the fluids to the lab for nalysis. Description P Lithium Bromide Analysis Kit: Uninhibited Nitrate inhibited Chromate inhibited molybdate Aresenite Inhibited Refrigerant Water P Lithium Chloride Analysis kit: Chromate Inhibited Molybdate Inhibited Available Options Octyl Alcohol Ammonia Arsenite Molybdate & Nitrate Purge Gas GCMS test for volatile arganic Contaminants Molybdate only Chromate Only Dissolved Fe Dissolved Cu P Brine Analysis Kit (Glycol) Freeze Pt & Concentration Only Total Condition Analysis BrineServe Energy Analysis P Fluid Loop Inventory Kit Glycol Fluid Analysis Glycol Fluid & Energy Analysis P Inorganic Brine Analysis P Cooling Tower Water Analysis Ammonia Other Element P Standard Oil Analysis Kit Chlorides/Fluorides Ion Activity Viscosity Mixed Oil Percentage P Refrigerant Analysis Kit Includes DOT Approved Sample Cylinder, Shipping And Labeling Instruction. Other refrigerant contamination Non-Condensables Standard Service 5-7 days turnaround Oil lib r, refrigerant water & glycol samples RUSH Service hours turnaround Oil lib r, refrigerant water & glycol samples 2 Totaline Universal HVAC/R Part and Supplies Totaline.com

37 TOTALINE CHEMICALS Chemicals - Coil Cleaners Internal Coil Cleaner Condenser Cleaner Non-Acid Concentrate Features: Foams out stubborn deposits from coils. Very effective on heavy grease accumulations. Ideal for cleaning grease contaminated refrigeration coils and condensers. USDA accepted P OZ AEROSOL P GAL (3.8 liters) P GAL (22.7 liters) P GAL (133 liters) P GAL (208.2 liters) Indoor Coil Cleaner Concentrate Features: Cleans and treats air-conditioning systems for maximum efficiency Retards future dirt accumulation Eliminates slime in condensate areas Easy to use, non-toxic and deodorizes Only equipment required is hand-type sprayer. USDA accepted. Features: Cleans interior lines in air conditioning and refrigeration systems after compressor burnout or prior to new installation. Breaks down carbon deposit, tar sludge, oil, grease & neutralizes acids in systems. Environmentally sound replacement for R11, R12 and chlorinated solvents. Does not contaminate refrigerant or oil, contains no CFCs, leaves no residue. Biodegradable. P GAL (3.8 liters) Condenser Cleaner Non-Acid Super Concentrate Features: Non-acid super concentrate is formulated with twice the active ingredients insuring a much more versatile cleaner with multiple dilution rates for cleaning applications. Non-acid super concentrate is non acid for improved user safety and yet produces excellent foaming action, superior cleaning, even on greasy surfaces and effectively brightens aluminum this one versatile product allows the user to efficiently and economically clean virtually any component of the a/c system. Oils & Chemicals P GAL (3.8 liters) P GAL (22.7 liters) P GAL (208.2 liters) P oz. Aerosol P B 1 GAL (3.8 liters) Non-Acid Total Bright Condenser Cleaner And Brightener Indoor Coil Cleaner Self-Rinsing Super Concentrate Features: No foaming action - only attacks dirt buildup, not metal. Dilutes with 24 parts water - 1 quart makes over 6 gallons evaporator cleaner. Rinsing not required - normal condensation will carry away dirt and contamination. Contains no toxic petroleum solvents, & the surfactants used are biodegradable. P A Features: Brightens better than typical alkaline products. Foams out stubborn deposits from air cooled condensers. Ideal for cleaning and brightening grease contaminated air conditioning condensers. 1 GAL (3.8 liters) P A 1 GAL (3.8 liters) Totaline Universal HVAC/R Part and Supplies Totaline.com 3

38 TOTALINE CHEMICALS Chemicals - Coil Cleaners Indoor Coil Cleaner Base, Super Concentrated Oils & Chemicals Environmentally Sound Coil Cleaner Safely cleans both evaporator and condenser coils without potential damage to equipment, personnel or the environment. Unlike strong acid or highly alkaline cleaners that actually eat away a thin layer of aluminum to remove contamination, it attacks only the dirt build up and leaves metal surfaces clean and free of corrosion. P GAL (3.8 liters) P GAL (22.7 liters) P GAL (208.2 liters) Outdoor Condenser Cleaner Concentrate Features: Foams out stubborn deposits from air cooled condensers Reduces head pressure Increases system capacity Only equipment required is plastic or other acid-resistant hand-type sprayer This self-rinsing base effectively cleans evaporators, removes mold, dust, and greasy residue. Concentrated, you just add water. No rinsing required. Dilution Rate = 24 parts water P oz. (.95 liters) Chemicals - Other Cleaners Electronic Air Cleaner Concentrate Easily removes grease, soot, grime, oil, tobacco tars, wax, carbon, gummy dust, and many other stubborn deposits. Electronic air filters Permanent filters Air ducts and grills Heating parts Fan blades and blowers Refrigeration parts USDA accepted P GAL (3.8 liters) P GAL (3.8 liters) P GAL (22.7 liters) P GAL (208.2 liters) Outdoor Coil Cleaner Base, Super Concentrated No extra water added...100% cleaning ingredients. Non-acid formula with foaming action to clean even the most greasy surfaces. Dilute with water for use on air-cooled condensers, evaporators, and electronic filters. P oz. (.95 liters) P GAL (208.2 liters) Scale Remover (Low Foaming) Features: Safely removes scale, heavy slime and algae from: cooling towers, condensers, and pipes Reduces head pressure Increases system capacity Reduces power consumption Labor saving P GAL (3.8 liters) P GAL (22.7 liters) P GAL (208.2 liters) Scale Remover With ph Indicator Eliminates the tedious and time consuming necessity of constantly checking the activity of the cleaning solution with ph paper. P GAL (3.8 liters) P GAL (22.7 liters) 4 Totaline Universal HVAC/R Part and Supplies Totaline.com

39 TOTALINE CHEMICALS Chemicals - Other Cleaners Ice Machine Cleaner (Metal Safe) Chemicals - Protectors, Inhibitors and Sanitizers Winter Corrosion Protector A non-foaming metal safe ice machine cleaner. safe to use on all types of ice machines including those with nickel plated drums. Meets Manitowoc s specification GES-6. USDA accepted. P OZ (.24 liters) P GAL (3.8 liters) Protects interior of chilled water systems that have been drained for winter lay-up. Spring start-up labor and equipment deterioration are greatly reduced by the prevention of corrosion and rust in the system. P GAL (22.7 liters) Oils & Chemicals Degreasing Solvent One Shot Scale And Corrosion Inhibitor Non-chlorinated full strength that combines cleaning effectiveness with personal safety and environmental concerns. Slow evaporating. Contains no toxic substances as defined by SARA Title III, Section 313. P GAL (3.8 liters) P GAL (208.2 liters) Solvent Cleaner And Degreaser Removes oil, grease and grime from mechanical parts, sheet metal, switches, motor armatures, etc. Spray, soak or brush parts. Controlled evaporation ensures deep soil penetration for effective cleaning. Nonchlorinated, high flash point (140 F), pleasant citrus scent. P GAL (3.8 liters) P * 32 oz. (.95 liters) *Spray Bottle Total 9 Buffered ph Cleaner, Concentrate Concentrated all purpose cleaner, formulated to quickly remove grease and heavy soils. Cleans any washable, nonporous surface. Environmentally friendly, safer to use alternative to bleaches, solvents and toxic cleaners. Excellent in parts washers. Ideal formulation for use on HVAC equipment, appliances, boat, truck, RV exteriors. Easily cleans glass and stainless steel. P Gal (3.8 liters) Features: Multifunctional liquid cooling water treatment Keeps recirculation cooling water in a buffered alkaline state. Inhibits microbiological growth and maintains water quality Coil And Duct Sanitizer Spray Algeacide P GAL (3.8 liters) P GAL (22.7 liters) P GAL (208.2 liters) EPA registered as a bacteriostat, fungistat, germistat and all purpose deodorizer for use on HVAC systems (including duct work and evaporator coils). Controls microorganism growth and eliminates odors caused by their growth. Easy to use. Clean the area and thoroughly spray all parts. Environmentally safe. P GAL (3.8 liters) P * 32 oz. (.95 liters) *Spray Bottle A quaternary ammonium chloride formulation that quickly destroys algae and slime to improve cooling system performance. Noncorrosive, safe on wood, metal and plastics. Non-foaming, non-volatile. P GAL (3.8 liters) Totaline Universal HVAC/R Part and Supplies Totaline.com 5

40 Oils & Chemicals TOTALINE CHEMICALS Chemicals - Protectors, Inhibitors and Sanitizers System Sanitizer, Concentrated EPA registered specifically for HVAC and air duct sanitation and deodorization. Concentrated and easily applied with the use of a hand held fogger or air driven sprayer to mist through a pre-cleaned system. No rinsing is required. Effective against a broad spectrum of microorganisms. No toxic chemical residue or odors. P oz. (96ml) Leak Reactant Totaline Leak Reactant provides a quick and easy way to pinpoint gas leaks from any pressurized gas system. Thick, tacky fluid clings to surfaces even the underside of pipes, and instantly produces an easy to see, long lasting stream of bubbles. Quart size spray bottles include heavy duty adjustable trigger sprayer Available in one gallon size refills non - clogging, non- hazardous, non- corrosive, biodegradable formulaton. P QT (.95 liters) P GAL (3.8 liters) Fin Protectant Other Chemicals Flame Retardant FIN Protectant is a specially formulated coating containing acrylic polymers and anti-corrosion agents designed to protect painted or unpainted metals from rust and corrosion. FIN Protectant seals and protects aluminum, copper, brass, bronze, chrome, galvanized metal, titanium, and stainless steel. It is ideally suited for use on air cooled condensers located in corrosive environments such as airports, adjacent to freeways, and salt air areas. Recommended for use with P Condenser Cleaner. P GAL (3.8 liters) P oz (454 gr) aerosol can Inhibits the spreading of flames on natural fiber materials. Non-hazardous and easy to use, it will not retard and synthetic, metal, plastic, or other man-made or previously treated material. Gas Leak Locator Features: Large leaks bubble up immediately Slow, small leaks bubble up within a few seconds Wasp And Hornet Spray P OZ. (.24 liters) P GAL (3.8 liters) Features: Dielectric strength over 40,000 v/cm Iong spray pattern up to 20 feet aid in reaching nests 16 oz. Can (454 grams) P Totaline Chemical Accessories Trigger Spray With Extension Tube P oz (.95 liters) A heavy duty trigger sprayer with a 24 extension tube and cap. Easily attaches directly to a one gallon bottle P Totaline Universal HVAC/R Part and Supplies Totaline.com

41 TOTALINE CHEMICALS Totaline Chemical Accessories Chemical Fogger One Quart Spray Bottle Tank Sprayer Designed especially for smaller jobs. Heavy duty, handy trigger P High quality plastic pressure sprayer with funnel top for easy filling. Reinforced 36 (91 cm) hose and 12 (30 cm) poly/brass wand with adjustable spray head. Operating Capacity P GAL (7.56 liters) 1-1/2 GAL (5.67 liters) P /2 GAL (5.67 liters) 1 GAL (3.8 liters) The Totaline P Chemical Fogger is used for applying sanitizers, disinfectants, and deodorizers. Excellent for these effective Totaline products: Totaline Coil and Duct Spray: (P , P ) Totaline System Sanitizer: (P ) Total Fresh Odor Neutralizer: (Liquid P , P ) 1-1/2 gallon, durable, one-piece, seamless tank 3-1/2 opening for easy filling Versatile 48 Flex hose Adjustable flow from 0-18 oz/min 110v/60Hz, 2-stage motor Constructed entirely of corrosion-resistant materials Dispenses materials (water based, room temperature) at average droplet size from 20 to 80 microns Easy clean-up Oils & Chemicals Foam Cleaning Fluid & Foam Cleaning Gun P Totaline Condensate Drip Pan Cleaner Features: Formulated to clean coils Gun attached to garden hose and applies cleaning solution at proper dilution P GAL (3.8 liters) P GAL (22.7 liters) P GAL (208.2 liters) P Foam Fluid Gun Features: EPA registered. Water Activated. Time released control of microbial contaminants. Reduces foul odors, drain stoppages, corrosion and promotes system hygiene. Kills mold, algae, fungus, legionella bacteria and other microorganisms. High capacity lasts up to 6 months. Unit Application P x 3/4 x 1/4 Window / Fan and Coil (Bulk Pkg. 20 Strips) P x 3/4 x 1/4 Window / Fan and Coil P x 1-1/4 x 1/4 Up to 2.5 Tons P x 1-1/2 x 1/4 3-5 Tons P x 1-1/2 x 5/ Tons P x 3 x 5/8 Up to 20 Tons P x 3 x 5/ Tons Totaline Universal HVAC/R Part and Supplies Totaline.com 7

42 TOTALINE CHEMICALS Totalfresh II Odor Neutralizer Total Tabs For Condensate Drain Pans Oils & Chemicals Features: Safe, easy to use, and completely soluble. Formulated with the compound at-8, are non-toxic and noncorrosive. Clean sludge, scum, and other accumulations in condensate pans preventing odors caused by these accumulations. P TABS New pleasant scent, white colored. Description P /2 lb tub P lb tub P lb tub Totalfresh Odor Neutralizer Features: Eliminates odors and air contamination. Inhibits the growth of certain molds and bacteria. Solid gel which is basically odorless after 12 hours. Draws the smell out of the air to give you a clean and healthful atmosphere. Light odor 1/2 to 1 lb/400 sq ft. Medium odor 2 lbs/400 sq ft. Heavy odor 3 to 4 lbs/400 sq ft. Aqua color. Use 3 lb tubs in central air return ducts. Description P /2 lb tub P lb tub P lb tub P oz spray bottle (citrus scent) P lb pail P lb blocks for wall unit P Wall unit with 6 blocks P oz spray bottle (unscented) 8 Totaline Universal HVAC/R Part and Supplies Totaline.com

43 TOTALINE CHEMICALS Touch-Up Paint Touch-up Spray Paint comes in 16 ounce cans, ideal for various touch-up jobs. All paint labels meet O.S.H.A. requirements and Federal Safety Codes. Paint Color Series Used On PH23JA012 Gloss Ivory Misc. PH23WL012 Alpine Mist 28, 400B, OH PH23GH018 Parchment 36R,S, 42A,B, 50BQ PH23ZS016 Silver Sage 28, 34, 58, 40, , 350, 355, 58MXA, 58MVP, 394C, 58WAV, 376C, 58ZAV PH23GH019 Fawn Beige 51 PH23FS010 Sand Beige 50BT, BU PH23NB015 Malibu Beige 58ES PH23PE023 Silver Grey 38CQ, EC, UE, TO, HO, TE, RQ, RE, QW, QF, VE, VH, VJ, VT, QB Dark Grey TECH Light Grey TECH Sand Piper Beige Reliant/Endura S/S Kona Black Cond Coils Swiss Mosha Brown Cobra, Eventemp S/S Gray Mist Furnace Prod after 9/95 Models 373LAV, 383KAV, 58RAV, 58PAV, GB1AAV, GB3AAV PH23GL012 Sea Spray Green Misc. 38, 48, 50, 58, 38GR, CB, CC PH23VS016 Vista Green (Dull Finish) CE,EA,EB,SE, EE PH23VS017 Vista Green (High Gloss) 38GR, CB, CC, CE PH23GH020 Pale Green 38GF, 40GC PH23PC016 Medium Green 38CU PH23GH017 Horizon Green 19D,C PH23TZ150 Midnight Blue 58SE 38UE Blue (for coils) 38VE, VH, VJ, VT,UE PH23US016 Burgundy (for coils) 38CO, RQ PH23RZ016 Chocolate Brown 58SE PH23FH010 Chocolate Brown 58HK, HM, HS, HW PH23RZ010 Chocolate Brown 50BT, BU PH23SS012 Chestnut Brown 38EC, ED 38LE Light Green -- 42CA Parchment Beige -- 48KH33178DP23 Dark Green -- PH23SG016 Grey Metallic -- 42CA Champagne Beige -- 37AE White Acrylic Enamel -- Oils & Chemicals Totaline Universal HVAC/R Part and Supplies Totaline.com 9

TOTALINE PROTECTION CONTROLS

TOTALINE PROTECTION CONTROLS TOTALINE PROTECTION CONTROLS SOLID STATE HEAD PRESSURE CONTROL WITH OPTIONAL HEAT PUMP OVERRIDE Head Pressure Controls Temperature sensitive fan motor control which regulates head pressure at low ambients

More information

Part # Features & Applications Specifications Cross Reference

Part # Features & Applications Specifications Cross Reference Solid State Controls 24-ICM450 24-ICM400 Fully Programmable - with LCD diagnostic display. Easy to configure - simple 7-step push-button setup. Easy to customize - set points, variables and features are

More information

TOTALINE PROTECTION CONTROLS

TOTALINE PROTECTION CONTROLS TOTALINE PROTECTION CONTROLS SOLID STATE HEAD PRESSURE CONTROL WITH OPTIONAL HEAT PUMP OVERRIDE Head Pressure Controls Temperature sensitive fan motor control which regulates head pressure at low ambients

More information

TOTALINE CAPACITORS RUN CAPACITORS OVAL MOTOR RUN CAPACITORS DUAL SINGLE

TOTALINE CAPACITORS RUN CAPACITORS OVAL MOTOR RUN CAPACITORS DUAL SINGLE TOTALINE CAPACITORS RUN CAPACITORS OVAL MOTOR RUN CAPACITORS P 2 9 1 - RUN CAPACITOR SINGLE P238 MFD PART NUMBER SIGNIFICANCE MFD NON-PCB DIELECTRIC FLUID UL APPROVED CURRENT INTERRUPTER MULTIPLE ELECTRICAL

More information

HVACR Controls by ICM

HVACR Controls by ICM HVACR Controls by ICM Specifically designed for Heating, Ventilation, Air Conditioning and Refrigeration Applications Motor protection Defrost Controls Duty cycle timers Delay on make timers Delay on break

More information

Table of Contents. HCC Contactor Nomenclature

Table of Contents. HCC Contactor Nomenclature Table of Contents HC HCC SERIES: Definite Purpose Contactors... Page 1 Auxiliary Switches & Termination Drawings HCC SERIES: 1 & Pole Definite Purpose Contactors... Page 0 HCC SERIES: & Pole Definite Purpose

More information

PULLOUT DISCONNECT SWITCHES

PULLOUT DISCONNECT SWITCHES PULLOUT DISCONNECT SWITCHES Includes multiple knockouts on all enclosure sides Rainproof NEMA 3R outdoor enclosure Pullout Disconnect Switches Fused (Top Open) ENCLOSURE MATERIAL DOOR STYLE VOLTAGE (V)

More information

JARD by MARS JARD by MARS

JARD by MARS JARD by MARS Table of Contents Description Page No. Capacitors Motor Run....................................................................................... J-3 J-5 Motor Start...........................................................................................J-6

More information

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q 14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose

More information

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)

Coil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT) 14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose

More information

Phone: Fax: Web: -

Phone: Fax: Web:  - Timer - Delay-on-Make The TAC1 Series was designed to delay the operation of a compressor relay. It eliminates the possibility of relay chatter due to half-wave failure of the output. It connects in series

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

SECTION MOTOR CONTROL

SECTION MOTOR CONTROL SECTION 26 24 19 MOTOR CONTROL PART 1 - GENERAL 1.1 SECTION INCLUDES A. Manual motor starters B. Magnetic motor starters C. Combination magnetic motor starters D. Solid-state reduced voltage motor starters

More information

For information on our complete range of American-made products plus wiring diagrams, troubleshooting tips and more, visit us at

For information on our complete range of American-made products plus wiring diagrams, troubleshooting tips and more, visit us at Our products are proudly manufactured in the USA For information on our complete range of American-made products plus wiring diagrams, troubleshooting tips and more, visit us at www.icmcontrols.com About

More information

AC Leak Freeze AIR CONDITIONING. AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems

AC Leak Freeze AIR CONDITIONING. AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems AC Leak Freeze AC Leak Freeze permanently seals leaks in air conditioning and refrigeration systems Will continue to seal additional Leaks for up to 1 year that meet testing specifications Does not contain

More information

Midget & Electronic Fuses

Midget & Electronic Fuses Midget Fuses 50-5 Electronic Fuses 55-59 Automotive Fuses 0-005 Littelfuse POWR-GARD Products Catalog w w w. l i t t e l f u s e. c o m Midget Fuses Supplementary Overcurrent Protection KLK Fuses Fast-Acting

More information

Application Engineering

Application Engineering Application Engineering March 2011 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital compressor or the

More information

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4 CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power

More information

Fuseholders PAGE. Fuseholders.

Fuseholders PAGE. Fuseholders. PAGE International Shock-Safe (Panel Mount).......................................................................... 467-468 Flip-Top Shock-Safe (Panel Mount)..................................................................................

More information

Industrial Control Transformers

Industrial Control Transformers 6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids

More information

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers

More information

Timer Relays - Fixed & Adjustable

Timer Relays - Fixed & Adjustable Solid State Solid State relays are suitable across all applications where reliability is paramount. Unlike conventional relays, Solid State relays use electronics in place of traditional contacts, allowing

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

Horizontal Circuit Switchers

Horizontal Circuit Switchers > Transformer Protection > CIRCUIT SWITCHERS C A T A L O G B U L L E T I N General Application Southern States Types CSH and CSH-B Horizontal Circuit Switchers provide an economical, versatile, space saving

More information

MODEL 422 Submersible Pump Controller

MODEL 422 Submersible Pump Controller MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

Thermal-cutoff, Fuse and Fuseholder Incorporated into a Simple Compact Device

Thermal-cutoff, Fuse and Fuseholder Incorporated into a Simple Compact Device Thermal-cutoff, Fuse and Fuseholder Incorporated into a Simple Compact Device It is generally known to employ a fuse for overcurrent protection and a thermal fuse or a thermostat for overheat protection

More information

OTEC Transfer switch open transition

OTEC Transfer switch open transition Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator

More information

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE

IMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE USER MANUAL IMI vibration switch INSTALLATION - OPERATION - MAINTENANCE Z0929039_A ISSUED 03/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. contents Overview General

More information

BLADE TERMINAL AND SPECIAL PURPOSE FUSES

BLADE TERMINAL AND SPECIAL PURPOSE FUSES BLADE TERMINAL AND SPECIAL PURPOSE FUSES LOW VOLTAGE ATO Fuse Fast-Acting Type U L Designed and originated by Littelfuse for the automotive industry, the ATO fuse has become the original equipment circuit

More information

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave Rectifiers for use with Armature Actuated Brakes Product Overview NOTE: For brake response times with and without rectifiers see page 94. Full Wave A rectifier in which both positive and negative half-cycles

More information

Transfer switch OTEC and OTECSE open transition

Transfer switch OTEC and OTECSE open transition Specification sheet OTEC and OTECSE open transition 125-600 Amp Description OTEC transfer es are designed for operation and ing of electrical loads between primary power and standby generator sets. They

More information

BF Series Flasher Thermal flasher circuitry

BF Series Flasher Thermal flasher circuitry BF Series Flasher Thermal flasher circuitry Long life 2A load rating @ 115V AC Low cost Small size All units work on AC and DC input voltage 3 terminal configuration 6V to 115V input voltages available

More information

Electropneumatic Timing Relays Series 7000 Industrial

Electropneumatic Timing Relays Series 7000 Industrial DESIGN FEATURES Available in On-Delay, True Off-Delay, and On/Off-Delay. Timing from 0.1 seconds to 60 minutes, fully calibrated in linear increments. Oversize time-calibrated adjustment knobs, serrated

More information

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards: SECTION 26 29 13 ENCLOSED MOTOR CONTROLLERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM Contents Section Page 1.0 Introduction 1 2.0 Specification 1-4 3.0 Installation 5-8 4.0 Programming 9-10 5.0 Menus 10-12 6.0 Fault Finding/Diagnostics 12-13 7.0 Communication 13 8.0 Setting Up 13-16 1.0

More information

Timer Relays - Fixed & Adjustable

Timer Relays - Fixed & Adjustable Solid State Solid State relays are suitable across all applications where reliability is paramount. Unlike conventional relays, Solid State relays use electronics in place of traditional contacts, allowing

More information

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS

Module 2 CONTROL SYSTEM COMPONENTS. Lecture - 4 RELAYS 1 Module 2 CONTROL SYSTEM COMPONENTS Lecture - 4 RELAYS Shameer A Koya Introduction Relays are generally used to accept information from some form of sensing device and convert it into proper power level,

More information

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are: Introduction Motor starters are one of the major inventions for motor control applications. As the name suggests, a starter is an electrical device which controls the electrical power for starting a motor.

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Application Description

Application Description -14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....

More information

Transfer switch OTEC open or delayed transition

Transfer switch OTEC open or delayed transition Transfer switch OTEC open or delayed transition 40-1000 Amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and standby generator sets.

More information

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC)

Switches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC) SWITCH SELECTION GUIDE Toggle Switches SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY (Resistive @ 115VAC, 28VDC) T1 2 or 3 Position, Momentary, 8A MIL-PRF-83731 15/32" or 1/4" dia.

More information

Circuit Breakers/Protection, Fuses/Fuse Products

Circuit Breakers/Protection, Fuses/Fuse Products Circuit Breakers/Protection, Fuses/Fuse Products CRCUT BREAKERS/PROTECTON, PAGES 169-172 FUSES/FUSE PRODUCTS, PAGES 174-182 i Understanding Type 1, Type 2 & Type 3 Circuit Breakers Type 1 Automatic Reset

More information

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS 550.13-TG1Y(98) SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS HCA300, 360, 80 & 600 5 THRU 50 NOMINAL TONS HCA80 DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece

More information

G72x Series Direct Spark Ignition Controls

G72x Series Direct Spark Ignition Controls Installation Sheets Manual 121 Gas Combustion Combination Controls and Systems Section G Technical Bulletin G72x Issue Date 1299 G72x Series Direct Spark Ignition Controls Figure 1: G72x Direct Spark Ignition

More information

A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures

A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures A419 Issue Date February 10, 2003 A419 Series Electronic Temperature Controls with Display and NEMA 1 or NEMA 4X Watertight Enclosures The A419 series controls are single-stage, electronic temperature

More information

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866) .4 Miniature Circuit Breakers and Supplementary Protectors SPHM Supplementary Protector SPHM Supplementary Protector Product Description The SPHM Supplementary Protector is a dual rated product for both

More information

Pressure Controls type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Pressure Controls type KPU REFRIGERATION AND AIR CONDITIONING. Technical leaflet Pressure Controls type KPU REFRIGERATION AND AIR CONDITIONING Technical leaflet Contents Page Introduction... 3 Features... 3 Approvals... 3 Materials in contact with medium... 3 Technical data... 4 Ordering...

More information

Transformer Disconnects

Transformer Disconnects Catalog April 05 Class 9070 CONTENTS Description..............................................Page Introduction................................................. 3 Standard Features............................................

More information

Introduction. Series P100. Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty. Feature and Benefits

Introduction. Series P100. Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty. Feature and Benefits PSC9919 European Refrigeration Controls Catalogue Catalog Section 6 Product Bulletin P100 Series P100 Encapsulated Pressure Control. Auto-reset Standard Duty and Heavy Duty. Manual reset Standard Duty.

More information

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400 Page -2 Page -4 Page -6 FOR BG SERIES MINI-CONTACTORS Type RF9, phase failure sensitive, manual resetting Type RFA9, phase failure sensitive, automatic resetting Type RFN9, non-phase failure sensitive,

More information

Pressure Control Type KPU

Pressure Control Type KPU MAKING MODERN LIVING POSSIBLE Data sheet Pressure Control Type KPU KPU controls are designed for use in refrigeration and air-conditioning systems to protect the systems from excessively low suction or

More information

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 15 Troubleshooting Basic Controls UNIT OBJECTIVES After studying this unit, the reader should be able to Describe and identify power- and non-power-consuming Describe

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation MATRIX FILTER SERIES D 600 Volts, 60HZ USER MANUAL PART NO. INSTR 026 REL. 080920 2008 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter is designed for harmonic mitigation

More information

Bussmann series Quik-Spec Coordination Panelboard

Bussmann series Quik-Spec Coordination Panelboard Quik-Spec electrical gear 12 Contents Bussmann series Quik-Spec Coordination Panelboard Section page Description Quik-Spec Coordination Panelboards Up to 400 A 2 600 to 1200 A 3 Quik-Spec elevator disconnects

More information

37T Series Moisture Resistant Temperature Controls

37T Series Moisture Resistant Temperature Controls 37T Series Moisture Resistant Temperature Controls Moisture Resistant Temperature Control The 37T series of 3/4 (19mm) bimetal disc temperature controls from Therm-O-Disc offers proven reliability in a

More information

Drop-in Alternative to Tyco/Kilovac* 500+ Amp EV200, plus a lot more (Compare Products) RoHS Compliant, all date codes

Drop-in Alternative to Tyco/Kilovac* 500+ Amp EV200, plus a lot more (Compare Products) RoHS Compliant, all date codes Drop-in Alternative to Tyco/Kilovac* 500+ Amp EV200, plus a lot more (Compare Products) RoHS Compliant, all date codes Patent Pending File E320908 All contact ratings and coil versions may not be UL recognized.

More information

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012 SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive

More information

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES

FRACTIONAL HORSEPOWER MOTORS & ACCESSORIES TABLE OF CONTENTS Motor Information Guide Definitions And Abbreviations... page 2 Motor Identification Without A Nameplate What To Look For... page 3 Direct Drive Blower Motors: Two Speed... page 4 Three

More information

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers IEC Rated C60N/H/L Circuit Breakers Standard Features Fast Closing Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when

More information

FLASHERS & TOWER LIGHTING CONTROLS

FLASHERS & TOWER LIGHTING CONTROLS FLASHERS & TOWER LIGHTING CONTROLS Flashers for incandescent or LED lighting used with both alternating and non-alternating applications in the signaling, communications, and advertising industries. FAA

More information

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS 1 Catalog KM-MCD-0818A Replaces KM-CSA-101A, KM-DSA-101A, KM-MSA-1213A, KM-CSE-101A and KM-MSE-101A DSA, CSA, MSA, CSE, AND MSE SERIES MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS MEDIUM

More information

HEAVY DUTY POWER RELAYS FEATURES

HEAVY DUTY POWER RELAYS FEATURES VDE VC HEAVY DUTY POWER RELAYS VC RELAYS Faston terminal Screw terminal mm 9 FEATURES VC power relays are designed for controlling heavy duty loads safely: Contact gap of 3 mm or more -point contacts for

More information

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING

Northwest RV Supply Manual Compliments of Printed From TROUBLESHOOTING TROUBLESHOOTING for the 5 BUTTON 3109228.001 COMFORT CONTROL CENTER SYSTEM INTRODUCTION The Comfort Control Center control system can be used to operate the following Duo-Therm Units: Roof Top Air Conditioners

More information

FLQ /2A 500V TD CT Midget Fuse. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories

FLQ /2A 500V TD CT Midget Fuse. Long Description. Manufacturer Information. Taxonomies, Classifications, and Categories 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 FLQ112 1-1/2A 500V TD CT Midget Fuse Littelfuse Catalog Number Manufacturer Description Weight per unit Product Category

More information

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control SERVICE UNIT INFORMATION SUPPLEMENT HP21 Corp. 9426 L10 Litho U.S.A. All HP21-4 and -5 units (single and three phase) are equipped with a TSC6 two-speed control. The TSC6 (A14) two-speed control contains

More information

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY CONNECTIONS INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION!! FOLLOW NATIONAL, STATE AND LOCAL CODES! READ THESE INSTRUCTIONS

More information

Command and signalling E 250, E 259 selection table

Command and signalling E 250, E 259 selection table E 250, E 259 selection table Latching relays E250 Installation relays E259 Contacts switching on each impulse sent to the control coil. Contacts maintained in switched position only while the control coil

More information

FLQ4 4A 500V TD CT Midget Fuse. Descriptions 4A 500V TD CT MIDGET FUSE Time Delay Midget Fuse 4 Amp. Manufacturer Information

FLQ4 4A 500V TD CT Midget Fuse. Descriptions 4A 500V TD CT MIDGET FUSE Time Delay Midget Fuse 4 Amp. Manufacturer Information 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 FLQ4 4A 500V TD CT Midget Fuse Littelfuse Catalog Number Manufacturer Description Weight per unit Product Category Descriptions

More information

DIFFERENTIAL THERMOSTAT

DIFFERENTIAL THERMOSTAT DIFFERENTIAL DSD-2 Differential Thermostat. This microcomputer based controller is capable of Testing and Controlling the Temperature Difference between Two remote locations. It reads the temperature from

More information

MERCURY CONTACTORS & RELAYS

MERCURY CONTACTORS & RELAYS MERCURY CONTACTORS & RELAYS PHONE: 704-399-4248 FAX: 704-399-4167 WWW.SETHERMAL.COM INDEX GLOSSARYOFTERMS&EXPRESSIONS...1 GENERALINFORMATIONFEATURES&SELECTIONFACTORS...13 MERCURY TO METAL CONTACTORS AND

More information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from Omron STI Application Support Thank you for your interest in Omron STI products. Please contact Omron STI with your application questions. Support Engineers are available at our USA headquarters from 4:00

More information

For more Parts Information:

For more Parts Information: For more Parts Information: https://manitowocfsg.sysonline.com/default.aspx TABLE OF CONTENTS Manitowoc Foodservice [Updated: Apr. 23, 2015] Manitowoc - Ice & Related Parts Catalog Ice Machine Indigo Series

More information

A419ABG-3C Electronic Temperature Control

A419ABG-3C Electronic Temperature Control Installation Instructions Issue Date June 16, 2003 A419ABG-3C Electronic Temperature Control Application IMPORTANT: Use this A419ABG-3C Electronic Temperature Control only as an operating control. Where

More information

HWP Protection Board

HWP Protection Board February 2009 HWP Protection Board Features and Operation This board provides the system protection features necessary to keep our HWP (Water Sourced Heat Pump) units safe in the instances when they are

More information

www. ElectricalPartManuals. com Systems Pow-R Breaker Transfer Switches Technical Data Page 1

www. ElectricalPartManuals. com Systems Pow-R Breaker Transfer Switches Technical Data Page 1 Cl November 1984 New Information Mailed to: E, D, C/29-900A Westinghouse Electric Corporation Distribution and Protection Business Unit Commercial Division - Assemblies London, KY 407 41 Technical Data

More information

CTi Automation - Phone: Fax: Web:

CTi Automation - Phone: Fax: Web: CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net The control & protection you expect in an innovative soft starter design... Flexibility

More information

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA: Supersedes: 160.55-PW4 (1199) FORM 160.55-PW4 (600) PRODUCT DRAWING YORK INTERNATIONAL CORPORATION P.O. Box 1592, YORK, PA 17405 CONTRACTOR ORDER NO. YORK CONTRACT NO. YORK ORDER NO. WIRING DIAGRAM FIELD

More information

The Benefits of AC Hard Starts

The Benefits of AC Hard Starts The Right Choice SEALED UNIT PARTS CO., INC. PO Box 21, 2230 Landmark Place Allenwood, NJ 08720 USA 800-333-9125 www.supco.com The Benefits of AC Hard Starts From the Pioneer of Hard Start Technology THE

More information

WATER SOURCE HEAT PUMPS REPLACEMENT PARTS MANUAL MODELS: General Notes. Contents. Important

WATER SOURCE HEAT PUMPS REPLACEMENT PARTS MANUAL MODELS: General Notes. Contents. Important REPLACEMENT PARTS MANUAL WATER SOURCE HEAT PUMPS MODELS: GTB-A GTA300UDAA GTA0UDAA GTC3S2-ADC GTCS2-ADC GTC0S2-ADC GTC3S2-ADN GTCS2-ADN GTC0S2-ADN Blower Section Coil Section Coil Section General Notes

More information

Shunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian

Shunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian Shunt Capacitor Bank Protection in UHV Pilot Project Qing Tian 2012-5 INTRODUCTION State Grid Corp. of China, the largest electric power provider in the country, has first build a 1000 kv transmission

More information

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING Matrix AP 400V 690V INSTALLATION GUIDE FORM: MAP-IG-E REL. May 2017 REV. 002 2017 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

Contacts The moveable contact, which is the one affected by the armature is sometimes referred to as the hinge contact.

Contacts The moveable contact, which is the one affected by the armature is sometimes referred to as the hinge contact. Relays & Wiring 101 Basically, a relay is an electrically operated, remotely controlled switch. A simple electromagnetic relay is an adaptation of an electromagnet. It consists of a coil of wire surrounding

More information

Designed for ease of integration with automation systems

Designed for ease of integration with automation systems BAS, 200 ~ 600V, 1/2-30HP BUILDING AUTOMATION STARTER SMARTER AND MORE VERSATILE THAN EVER Smartstart Equipped with advanced I/O including Fireman s Override and damper control, the BAS was designed from

More information

LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block

LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block 3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 LH600303C 1/10-30A 3P 600V Class H Box Lug Fuse Block Littelfuse Catalog Number LH600303C Manufacturer Littelfuse Description

More information

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h) Mechatronic Analog Timer H3AM Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and

More information

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK

SECTION MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK PART 1 - GENERAL 1.1 GENERAL: SECTION 15150 MOTORS, MOTOR STARTERS, VARIABLE FREQUENCY DRIVES AND ELECTRICAL WORK A. The Mechanical Contractor shall furnish to the Electrical Contractor for installation,

More information

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual Complete Installation and Operating Manual for the MEP 002/003 Auto / Remote Starter for the following MEP Power Generators: MEP 002A/003A/011A/802A/803A/811A

More information

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com

More information

OTPC-SE Service entrance transfer switch open transition

OTPC-SE Service entrance transfer switch open transition Specification sheet OTPC-SE Service entrance transfer switch open transition 40 1000 amp Description OTPC service entrance transfer switches are designed for operation and switching of electrical loads

More information

Digital Room Thermostats with Touch Screen LCD

Digital Room Thermostats with Touch Screen LCD TC40 Touch Series Digital Room Thermostats with Touch Screen LCD Revision Date February 22, 2013 Features Wall-mount Display Control to match any decor Extra large easy-to-read Liquid Crystal Display (LCD),

More information

PARTS & SERVICE MANUAL

PARTS & SERVICE MANUAL PARTS & SERVICE MANUAL Impinger Low Profile Advantage Digital Series (Electric) International Models MODELS: Please note that the model numbering system changed March 2007. The chart below shows the old

More information

wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS

wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 580F 036-150 3 to 12 1 / 2 Tons Cancels: New WD 580F.36.1 10/15/00 *Low NOx/California compliant units. DIAGRAM INDEX UNIT LABEL

More information

TA Ta VA CTRL-XFRMR

TA Ta VA CTRL-XFRMR 3804 South Street 7964-7263, TX Nacogdoches Phone: 936-69-7941 Fax: 936-60-468 TA2437 Ta-2-437 10VA CTRL-XFRMR Acme Electric Catalog Number TA2437 Manufacturer Acme Electric Description Control Transformer,

More information

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure 2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure SafeGear Motor Control Center Arc resistant Metal-Clad construction Brochure Table of Contents 1. Description 1 1 2. SafeGear

More information

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A PCB Relay Miniature Single-pole Relay with 80-A Surge Current and 20-A Switching Current Ideal for motor switching. Miniature, relay with high switching capacity built-in applications. Creepage distance

More information

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low

More information

Brief Operating Description: Longer Motor Life Starts with a Switch

Brief Operating Description: Longer Motor Life Starts with a Switch Contents Brief Operation Description............................................ 1 Application................................................... Design Features....................................................

More information