Flexible Sprinkler Connector Braided & Unbraided
|
|
- Isaac Rich
- 5 years ago
- Views:
Transcription
1 Model: FX / FXU Technical Features Hose Types: raided or Unbraided Hose Lengths:, 6, 8, 60, 7 Maximum Working Pressure: 75 PSI Maximum Working Temp: 5 F K factor: ½ Outlet 5.6, ¾ Outlet 8.0 onnections: To branch line (inlet) via /5.mm NPT male thread onnections: To sprinkler (outlet) via ½ or ¾ 5mm or 0mm NPT female thread pprovals & Standards raided: UL, UL, FM 67 Unbraided: UL, UL Part Material Flexible Hose Nut Type 0 Stainless Steel S0 Gasket Seal Nylon 66 Silicon Zinc Plated Grade 00 Steel End & enter rackets L Square ar Zinc Plated Steel Grade 00 Steel K J E. Stainless Steel Flexible Hose. onnection Nut G. Sprinkler H. Steel ar F G H I. Inlet Nipple D. E. enter racket I. J. K. F. L. ranch Line Inches Outlet Size Inches ends Min end Sch. 0 Pipe Inches Outlet Size Inches ends Min end Sch. 0 Pipe / / / / / / / / / / / / / / / / / / / /
2 Model: FX / FXU Inlet Nipple NPT FX RIDED UL / FM REDUER 5.5 Length* Inlet Nipple NPT FXU UNRIDED UL REDUER 5.5 Length* * Other Reducer lengths vailible Suspended eiling T-ar Grid System STNDRDS OF OMPLINE UL standards for Flexible Sprinkler Hose with Fittings for fire protection service Item Stainless Steel Flexible Sprinkler Hose Steel Square ar 5 & 50 97mm End racket with Wing Nut enter racket D-Type / or / Reducer NPT 97mm End racket with Wing Nut FM class number 67 approved standard for Flexible Sprinkler Hose with Threaded Ends and Fittings. NFP Standard for the installation of sprinkler system. NFP D Standard for the installation of sprinkler systems in one and two family dwellings and manufactured homes. NFP R Standard for the installation of sprinkler systems in residential occupancies up to and including four stories in height. STM 65 Standards specification for the manufacture, performance, and testing of metal suspension systems for acoustical tile and lay-in panel ceilings. STM 66 Standards practice for installation of metal ceilings suspension systems for acoustical tile and lay-in panels.
3 Model: FX / FXU Metal Joist / Stud (Option ). Metal Stud End racket (Part# FX-E-MTL). Metal Stud ( hannel) Package Includes: () Stainless Steel Flexible Sprinkler Hose () Steel Square ar () End rackets () enter racket Metal Joist / Stud (Option ). End racket (Part# FX-E-97MM). Metal Stud ( hannel). -/ #0 Self-Drilling Sheet Metal Screw Package Includes: () Stainless Steel Flexible Sprinkler Hose () Steel Square ar () End rackets () enter racket Wood Joist / Stud. End racket (Part# FX-E-97MM). Wood Joist. -/ #0 Self-Drilling Wood Screw Package Includes: () Stainless Steel Flexible Sprinkler Hose () Steel Square ar () End rackets () enter racket
4 Model: FX Parts List FX-NPT-050 FX-NPT-075 FX-NPT-700 FX-NPT-900 Straight Reducer /" Outlet x 5-/ Length Straight Reducer /" Outlet x 5-/ Length Straight Reducer /" Outlet x 7 Length Straight Reducer /" Outlet x 9 Length FX-NPT-INL FX-S-5 Square ar - 5" FX-S-50 Inlet Nipple x -/8 NPT Square ar - 50" FX-90D-50 FX-90D-75 90º Degree Elbow Reducer /" NPT 90º Degree Elbow Reducer /" NPT FX-GSKT EPDM Gasket FX- enter racket DX--D enter racket D TYPE FX-E-97MM 97mm End racket FX-E-MTL STUD Metal Stud End rackets
5 Model: FX Installation Instructions *For STM 65 metal ceiling suspension systems installed in accordance with STM 66 standards. WRNING * Read and follow these installation instructions before attempting to install Fivalco products. * Installer must understand the purpose of these products with common standards of the industry for safety, and the consequences of improper product installation. * Wear safety glasses, hardhat, and foot protection during installation. * Failure to follow these instructions could cuase improper sprinkler operation, resulting in serious personal injury and / or property damage. * The flexible hose are not to be bent within.5 inches of the connection nut at both ends. SSEMLY INSTRUTIONS () Pipe side: pply PTFE thread seal tape or pipe joint compound to the tapered threads of the inlet nipple. () Flexible hose side: DO NOT use both pipe PTFE or pipe joint compund. Tighten the inlet nipple into branch line using pipe wrench. onnect the nut of flexible hose to the inlet nipple using a pipe wrench. DO NOT use PTFE or pipe joint compound on the inlet nipple at the hose side since there is already a seal gasket in place to seal the joint. Tighten the connection to a maximum torque of 5 ft-lbs/0 N*m. Too much torque may cause damage to the seal gasket.
6 Model: FX Installation Instructions *For STM 65 metal ceiling suspension systems installed in accordance with STM 66 standards. onnect the nut of the flexible hose to the outlet reducer. DO NOT use PTFE or pipe joint compound since on outlet reducer at the hose side since there is already a seal gasket in place to seal the joint. Tighten the connection to a maximum torque of 5 ft-lbs/0 N*m. TOO much torque may cause damage to the seal gasket. 5 5 Indentify the t-bar bracket assembly and confirm if all parts are in present: () end bracket at each side, () center bracket, () square steel bar. djust as necessary if the positions of the end brackets to match the length of the t-bar rails. 6 6 ttach the end brackets to the t-bar rails by loosening the wing nut and pushing in the end bracket into the t-bar rail. 7 7 Tighten the wing nut to a torque of ft-lbs/ N*m to secure end brackets to the rails.
7 Model: FX Installation Instructions *For STM 65 metal ceiling suspension systems installed in accordance with STM 66 standards. 8 8 djust the positions of the center bracket and the flexible hose to desired location. 9 9 Slide the outlet reducer into the center bracket. 0 0 With outlet reducer positioned inside the center bracket, grasp and firmly close the handle completely to secure the reducer in place. Optional: Tighten the wing nut to a torque of ft-lbs/ N*m.
8 Model: FX Installation Instructions *For STM 65 metal ceiling suspension systems installed in accordance with STM 66 standards. pply PTFE or pipe joint compound to the male threads of sprinkler. Install the sprinkler into the female threads of the outlet reducer by following sprinkler manufacturer s installation instructions. HRD-LID EILING JOIST / STUD SSEMLY INSTRUTIONS Metal Joist / Stud (Option ) Refer to instructions for STM 65 Metal eiling Suspension Systems and perform steps to. Slide the Metal Stud End racket ( FX-E-MTL) on each end of square steel bar, making sure the lip of the bracket engages the metal joist/stud. Tighten the wing nuts to a torque of ft-lbs/ N*m to secure to the metal joist/stud. Perform steps 8 to of the STM 65 Metal eiling Suspension Systems. Metal Joist / Stud (Option ) Refer to instructions for STM 65 Metal eiling Suspension Systems and perform steps to. Place the bracket assembly on top of the metal joist/stud, where the end brackets ( FX-E-97MM) are on the inner side of each metal joist/stud. Drill -/ inch long #0 self-drilling sheet metal screws () in the locations shown in the picture. Perform steps 8 to of the STM 65 Metal eiling Suspension Systems. Wood Joist / Stud Refer to instructions for STM 65 Metal eiling Suspension Systems and perform steps to. Place the bracket assembly on top of the wood joist/stud, where the end brackets ( FX-E-97MM) are on the inner side of each wood joist/stud. Drill -/ inch long #0 self-drilling wood screws () in the locations shown in the picture. Perform steps 8 to of the STM 65 Metal eiling Suspension Systems.
I-VICFLEX.AB7 VicFlex Sprinkler Fittings for Ceiling Suspension Systems STYLE AB7
INTRODUCTION WARNING Read and understand all instructions before attempting to install any Victaulic VicFlex products. Wear safety glasses, hardhat, and foot protection. These installation instructions
More informationData Sheet 3.11 Issue F
General Description Rapidrop flexible sprinkler hoses are typically used as an alternative to traditional hard pipe arm overs and are particularly suited for use in suspended ceiling applications. The
More informationData Sheet 3.03 Issue D
Description Rapidrop Flexible Sprinkler Hose connects the sprinkler to the branch pipe. The flexible stainless steel hose and fittings are particularly suited for use in suspended ceiling applications.
More informationData Sheet 3.01 Issue C
Description Rapidrop Flexible Sprinkler Hose connects the sprinkler to the branch pipe. The flexible stainless steel hose and fittings are particularly suited for use in suspended ceiling applications.
More informationI-VICFLEX.AB1/AB2/AB10
INSTALLATION INSTRUCTIONS I-VICFLEX.AB1/AB/AB10 Victaulic VicFlex Flexible Hose with Fittings for Fire Protection Service Styles AB1, AB, and AB10 Brackets Flexible Hose Listing and Approval Information
More informationModel VKFD28 Flexible Sprinkler Drops (LPCB Approved) Installation Manual. January 2016 Form No. F_ Rev 16.1
Model VKFD28 Flexible Sprinkler Drops (LPCB Approved) Installation Manual January 2016 Page 2 of 10 TABLE OF CONTENTS Section Description Page 1 Benefits 3 2 Installation Instructions 3 3 Technical Data
More informationI-VICFLEX.AB11. Victaulic VicFlex Style AB11 Low-Profile Sprinkler Fitting for Suspended Ceiling Systems WARNING INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS I-VICFLEX.AB11 Victaulic VicFlex Style AB11 Low-Profile Sprinkler Fitting for Suspended Ceiling Systems Read and understand all instructions before attempting to install any Victaulic
More informationI-VICFLEX.AB5. Victaulic VicFlex Style AB5 Sprinkler Fitting for Wood or Metal Joists/Studs and CD Profile (60 mm) Channel Ceiling Systems WARNING
INSTALLATION INSTRUCTIONS I-VICFLEX.AB5 Victaulic VicFlex Style AB5 Sprinkler Fitting for Wood or Metal Joists/Studs and CD Profile ( mm) Channel Ceiling Systems WARNING Read and understand all instructions
More informationKOFULSO /Easyflex flexibles sprinklers drop distributed by
KOFULSO /Easyflex flexibles sprinklers drop distributed by Simplicity Flexibility Affordability No pipe cuting 100% corrosion-resistant 33 flexibles sprinklers drop distributed by ROLLAND Assembly KOFULSO
More informationPROFLEX FLEXIBLE SPRINKLER HOSES (PAGE 1/5)
FLEXIBLE SPRINKLER HOSES (PAGE 1/5) DESCRIPTION A flexible sprinkler hose assembly consists of a braided or unbraided hose with on one side an inlet connection for the branch line, and on the other side
More informationCOACHSTEP TRIPLE STEP RECALL REPAIR INSTRUCTIONS RECALL# 15E-078 LABOR FLAT RATE: 0.5 HOURS
Purpose OHSTEP TRIPLE STEP RELL REPIR INSTRUTIONS RELL# 15E-078 LOR FLT RTE: 0.5 HOURS The intent of this document is to provide instructions for the replacement of the oachstep Linkage ssembly and the
More informationInverted Dual High-Pressure Fluid Filter Assemblies
Instruction Sheet P/N 1093-04 Inverted Dual High Pressure Fluid Filter Assemblies Introduction WARNG: High pressure fluids are hazardous. To prevent serious injury when installing and servicing filters,
More informationINSTALLATION INSTRUCTIONS FREESTANDING ELECTRIC RANGE WITH DOUBLE OVENS
INSTLLTION INSTRUTIONS FRSTNING LTRI RNG WITH OUL OVNS Table of ontents RNG SFTY... 1 INSTLLTION RQUIRMNTS... 2 Tools and Parts... 2 Location Requirements... 2 lectrical Requirements... 4 INSTLLTION INSTRUTIONS...
More informationACCESSORIES & FITTINGS 800 SERIES CONTROL VALVES
ACCESSORIES & FITTINGS 800 SERIES CONTROL VALVES 8 VALVE FITTING PART NUMBERS 2" & 3" PRESSURE REDUCING VALVES* 10645 8970-002 (9526-006) 1/4" tube (9526-006) Flow 8970-001 (9526-001) 8970-010 (9526-010)
More informationPaint/Solvent/Dump Valve and Flow-Through Valve
Instruction Sheet P/N 08573D Paint/Solvent/Dump Valve and Flow-Through Valve. Description See Figure. The paint/solvent/dump valve is a normally-closed valve that opens to trigger and/or dump coating material.
More informationInverted High Pressure Fluid Filters
Instruction Sheet P/N 33290-03 Description See Figure. Nordson high-pressure fluid filters prevent nozzle-plugging by filtering contaminants out of coating materials. These stainless steel, wall-mounted
More informationSECTION 8 Fire Protection
Bronze Wet Barrel Fire Hydrants With over 100 years of experience on the west coast the heart of the wet barrel market James Jones Company, LLC is the innovator in the bronze wet barrel hydrant industry.
More informationFlexible Sprinkler Connections
SuperFlex is the ultimate solution in flexible fire sprinkler drops. No need to measure or count the number of bends, no leaks, no worries! SuperFlex provides all the flexibility needed for an error free
More informationListings and Approvals. G5 QR Gasket culus QR G5 SR Gasket culus, FM SR G5
Model Series Sprinklers Available with Solid, Perforated, or Gasket Standard Coverage, Concealed Pendent K2.8, 4.2, 5.6, & 8.0 (40, 60, 80, & 115 metric) Features Flat concealed cover plate available solid
More informationEasy Riser swing check valve Models E-1 & F-1
Page 1 of 7 1. DESCRIPTION The Viking Easy Riser Swing Check Valve is a general purpose rubber-faced approved for use in fire service systems. The valve is for use in wet system risers, preaction system
More informationSUPPLY JOINTS CONTENTS
ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS CONTENTS Specifications, Order Codes, Size Table 371 Dimensions 373 NCU Specification Order Codes, Model Table 379
More informationResilient-Seated Gate Valves with Vertical or Cross Wall Post Indicator
Worldwide ontacts www.tyco-fire.com Resilient-Seated Gate Valves with Vertical or ross Wall Post Indicator General Description TYO Resilient-Seated Gate Valves with Vertical and ross Wall Indicators are
More informationResilient-Seated Gate Valves with Vertical or Cross Wall Post Indicator
Worldwide ontacts www.tyco-fire.com Resilient-Seated Gate Valves with Vertical or ross Wall Post Indicator General Description TYO Resilient-Seated Gate Valves with Vertical and ross Wall Indicators are
More informationFAX
INSTALLATION INSTRUCTIONS 6090 Air Suspension Kit (pat. pending) 1999-2006 Tahoe, Suburban, Avalanche, Yukon Thank you for purchasing a quality Hellwig Product. PLEASE READ THIS INSTRUCTION SHEET COMPLETELY
More informationPowrTwin 6900GHD Insert Sheet
For professional use only PowrTwin 00GHD Insert Sheet Parts Lists and Service Instructions Main Assembly Model Numbers: Gas Bare -0 Gas Complete -0 Gas/Electric Complete -0 0V Electric International -0
More informationOPERATOR S MANUAL X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE INCLUDE MANUAL: S-632 GENERAL INFORMATION MANUAL (PN )
OPERATOR S MANUAL 650110-X INCLUDING: OPERATION, INSTALLATION & MAINTENANCE INCLUDE MANUAL: S-632 GENERAL INFORMATION MANUAL (PN 97999-624) 2 AIR MOTOR 2:1 RATIO 6 STROKE 2 DIFFERENTIAL TRANSFER PUMP (CARBON
More informationNylon Fluid Regulators
Instruction Sheet P/N 08880B Introduction The FR- and RA- nylon fluid regulators are patented, electrically non-conductive, air-operated, pressure regulators. Except for the body shape and fluid connection
More informationWelded Outlet Fittings For Fire Protection & Other Low Pressure Piping Systems
Welded Fittings For Fire Protection & Other Low Pressure Piping Systems SPF Welded Fittings offer the user a high strength, low cost forged threaded and grooved line of fittings specifically designed and
More information4. Remove (4) 10mm and (1) 7mm bolt that holds fascia at front corners, on each side
2010 Camaro LS3 1. Disconnect battery ground 2. Remove front wheels 3. Remove (5) push pins and (5) #20 torx screws on inner front wheel well liners and remove liners on each side 4. Remove (4) 10mm and
More informationMEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:
MEDIA LED Pendant Standard Mount WARNING: Disconnect main power at the source prior to installation! Thread gripper base onto 1 /4 20 stud, or with #8 screw. Depress gripper nozzle to insert aircraft cable.
More informationEscape Cylinder and Valve
Escape Cylinder and Valve MAINTENANCE AND REPAIR TAL 1601 (L) Rev. 2 MSA 2016 Prnt. Spec. 10000005389 (I) Mat. 10064389 Doc. 10064389 CYLINDER COMPONENTS Item Part No. Description 818159 5 Minute, Aluminum
More informationI-799/79V Coil Components
WARNING Read and understand all instructions before attempting to install any Victaulic products. Depressurize and drain the piping system before attempting to install, remove, or adjust any Victaulic
More informationMale stud fittings. Male stud elbow. Fluid... Working pressure... Vacuum level... Rated temperature...
FITTINGS Push - in fittings 431 Series Fluid... Working pressure... Vacuum level... Rated temperature... Torque... Standards... Materials... Compressed air Max. 20 bar (290 psi) 55 mm Hg vacuum (99 %)
More informationPRODUCT SAFETY NOTICE
PRODUCT SAFETY NOTICE Congratulations. This vehicle has been equipped with a Firestone air suspension system. This suspension will enhance the vehicle s handling when loaded, however, the vehicle s performance
More informationMiniature Fittings Stainless Steel 316. Hose nipple. Barb Configuration for easy insertion into the tube Holds the tube tightly.
Miniature Fittings Stainless Steel 316 Series MS Applicable Tubes: ø3.2, ø4, ø6 Connection Thread:, R 1/ For use in corrosive environments Compact piping space Tube has a large retaining force. Hose nipple
More informationModel RM-1 Riser Manifold Commercial and Residential General Description
Worldwide Contacts www.tyco-fire.com Model RM- Riser Manifold Commercial and Residential General Description The TYCO commercial and residential Model RM- Riser Manifold provide the necessary waterflow
More informationXP-300 Series Sprinklers Installation & Service Instructions
XP-300 Series Sprinklers Installation & Service Instructions Introduction The XP-300 Series Sprinkler is a multiple-stream gear-driven sprinkler ideal for residential and commercial applications. Sprinkler
More informationTubing. Barb. Sleeve. Attaching the sleeve achieves a larage retaining force. Detaching it allows easy removal of the tube. Electroless nickel plated
iniature Fittings Series pplicable Tubing: ø2 onnection Thread:, RoHS ade to Order (Refer to page 9 for details.) pplicable O.D. x I.D.: ø2 x ø.2 onnection thread: / One-touch fitting size: ø.2 / ø Tubing
More informationSection 3. Stainless Steel Series. Shurjoint Stainless Steel Piping Series Grooved Mechanical Couplings. Cast Grooved Fittings.
Section 3 Stainless Steel Series Shurjoint Stainless Steel Piping Series... 84 Grooved Mechanical ouplings SS-5 Rigid oupling... 85 SS-7 Rigid oupling... 86 SS-7X Rigid oupling... 87 SS-8 Flexible oupling...
More informationThe Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York Bulletin 617 Rev. C
ulletin 617 Rev. Model R ommercial Riser Riser Manifold for ommercial pplications ulletin 617 Rev. vailable Sizes/Pressure Ratings: 1 1 / 2 (40mm) and 2 (50mm) Threaded - 250 psi (17,2 bar) Working Pressure
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS GMT 560 (4500/5500) CREW CAB (2351A000) Link Mfg. Ltd. 223 15th St. N.E. Sioux Center, IA USA 51250-2120 The CABMATE MODEL 2351A000 fits the 2003 and later GM 4500 / 5500 crew
More informationValves & Flow Control Components Valves & Flow Control Components
Section 4 Valves & Flow ontrol omponents Valves & Flow ontrol omponents... 106 SJ-200 Low-Profile utterfly Valve... 107 SJ-300N utterfly Valve... 108 SJ-300F utterfly Valve (for Fire Protection)... 110
More informationIntroduction. We stay ahead of today s evolving market requirements by committing to a program of continued research and development.
Pipes & Fittings SHIELD Introduction SHIELD is a company created to cater to the infrastructure, fire protection and building services industries with a comprehensive range of products designed to be competitive
More informationPRODUCT SAFETY NOTICE DEALER/INSTALLER NOTICE
PRODUCT SAFETY NOTICE Congratulations. This vehicle has been equipped with a Firestone air suspension system. This suspension will enhance the vehicle s handling when loaded, however, the vehicle s performance
More informationMiniature Fittings Series M
Miniature Fittings Series M pplicable Tubing: Ø 3.2, Ø 4, Ø 6 onnection Thread:, M, arb onfiguration for easy insertion into the tube Holds the tube tightly ody With electroless nickel plated Low tightening
More informationDEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE
DEFENDER SERIES 5 Gallon, Double Walled, Field Replaceable Spill Container Model 705-550 Series INSTALLATION, OPERATION, & MAINTENANCE Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Tel:
More informationINSTALLATION INSTRUCTIONS Auto Level Compressor Kit IMPORTANT NOTES
INSTALLATION INSTRUCTIONS 4880 Auto Level Compressor Kit Thank you for purchasing a quality Hellwig Product. PLEASE READ THIS INSTRUCTION SHEET COMPLETELY BEFORE STARTING YOUR INSTALLATION IMPORTANT NOTES
More informationINSTALLATION INSTRUCTIONS Air Spring Kit Dodge WD IMPORTANT NOTES
INSTALLATION INSTRUCTIONS 6211 Air Spring Kit 2003+ Dodge 1500 4WD Thank you for purchasing a quality Hellwig Product. PLEASE READ THIS INSTRUCTION SHEET COMPLETELY BEFORE STARTING YOUR INSTALLATION IMPORTANT
More informationINSTALLATION, OPERATION, AND MAINTENANCE MANUAL
INSTALLATION, OPERATION, AND MAINTENANCE MANUAL MODEL 4D-200 REDUCED PRESSURE PRINCIPLE (RPZ) & MODEL 4D-700 REDUCED PRESSURE DETECTOR ASSEMBLY (RPDA) BACKFLOW PREVENTERS 2 ½ 10 Conbraco Industries Inc.
More informationMiniature Regulator. Standard Specifications. Model IN side OUT side (Applicable tubing O.D.) Proof pressure Maximum operating pressure
Miniature Regulator Series 00F Compact and lightweight ( g) Low cracking pressure 0.0 MPa Standard model equipped with backflow function Standard Specifications Port size Fluid side side (Applicable tubing
More informationBlow Off Valve Retrofit Kit
Instruction Sheet P/N 37 56C low Off Valve Retrofit Kit WRNING: llow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation..
More informationINSTALLATION INSTRUCTIONS FRONT CONTROL ELECTRIC RANGES
INSTLLTION INSTRUTIONS FRONT ONTROL ELETRI RNGES Table of ontents RNGE SFETY...2 INSTLLTION REQUIREMENTS...3 Tools and Parts...3 Location Requirements...3 Electrical Requirements - U.S.. Only...5 INSTLLTION
More informationFluidizing Pickup Tube Kits
Instruction Sheet P/N 303787-02 Introduction The fluidizing pickup tube kit retrofits your existing mobile powder system with fluidizing air. It injects fluidizing air at the pickup tube inlet with minimal
More informationTube Applicable for nylon, soft nylon and polyurethane tubing.
Miniature Fittings Series M pplicable Tubing: ø3.2, ø4, ø6 onnection Thread:, M, arb onfiguration for easy insertion into the tube Holds the tube tightly ody With electroless nickel plated Low tightening
More informationTECHNICAL DATA OBSOLETE
August 31, 2006 Check Valve 815a 1. PRODUCT NAME Viking Easy Riser Swing Check Valve Model E-1: Available since 1992 Model F-1: Available since 1994 2. MANUFACTURER The Viking Corporation 210 N. Industrial
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS FOR COLD PLANER sprinkler KIT (LAF5400) INSTRUCTIONS NUMBER: MR05678 Complete operator s and parts manuals are supplied with the Cold Planer. 800-456-7100 www.paladinlcg.com 2800
More informationargco.com
800-854-1015 argco.com STRUT SUPORT SYSTEM STRUT SUPPORT CHANNEL US Strut Support Channel Quick, strong attachment of single or multiple pipes horizontally or vertically Unlimited applications - range
More informationSignet 2517 Brass Paddlewheel Flow Sensor * *
Signet 2517 Brass Paddlewheel Flow Sensor -250.090 English -2517.090 Rev. F 11/06 English SAFETY INSTRUCTIONS 1. Do not remove from pressurized lines. 2. Do not exceed maximum temperature/pressure specifi
More informationI-317. AWWA Check Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS SERIES 317 WARNING
Read and understand all instructions before attempting to install, remove, adjust, or perform maintenance on any Victaulic piping products Wear safety glasses, hardhat, and foot protection. Failure to
More informationER TRANSIT PARTS MANUAL. Cooling Section. Page 7-1. Cooling 05/97
Cooling Page 7-1 Plumbing Cummins 6BTA/6BG Page 7-2 Cooling Plumbing Cummins 6BTA/6BG 1 62190751 1 Tube - Coolant, Lower Radiator 2 61190162 3 Clamp - 2 1/16" - 3" 3 61190422 1 Hose - Rubber, Curved 2
More information27" Natural Gas Conversion Manual
S o n o m a PLATINUM EDITION 27" Natural Gas Conversion Manual FOR OUTDOOR USE ONLY TM 1 2 3 4 8 7 5 9 6 Part No. Qty Description 1 44213827 1 Hose 27" - 3/8" Flare Both Ends for Side Burner (NG) 2 40275101
More informationDocument: 3 inch Vane Pump System-in-a-Box Assembly Instructions SPS100370
1.0 What is a System-in-a-Box? System-in-a-Box for 3 inch vane pumps (SPSZRS-V3N VANE SYS KIT) contains all of the castings, mounting plates and hardware that make up the base system, with the exception
More informationTECHNICAL DATA CAUTION
Page 1 of 6 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood assembly, used to increase the operating speed of a differential type dry pipe valve.
More information2 NPT FILTER REPLACEMENT SCREENS FOR 1 1/4 & 2 FILTERS
ALUMINUM Y FILTERS 50 GPM Rating is with the lowest flow screen with no head loss. 200 PSI Max Working pressure. 80 GPM Rating is with the lowest flow screen with no head loss. 200 PSI Max Working pressure.
More informationFire Protection Price List
Piping. Systems. Solutions. Fire Protection Price List The Victaulic website is an information resource that can help you with your piping projects. Among the many resources available at the site: Fully
More informationModel CV-1FR Grooved-End Riser Check Valves 2 Inch to 12 Inch (DN50 to DN300) General Description. Installation. Technical Data
Worldwide Contacts www.tyco-fire.com Model CV-FR Grooved-End Riser Check Valves Inch to Inch (DN0 to DN00) General Description The TYCO Model CV-FR Grooved- End Riser Check Valve is a compact and rugged
More information1 1/4 NPT FILTER 2 NPT FILTER REPLACEMENT SCREENS FOR 1 1/4 & 2 FILTERS 1 1/4 SCREENS 2 SCREENS. Hole Size Designation 150 Mesh 1M150
ALUMINUM Y FILTERS 50 GPM Rating is with the lowest flow screen with no head loss. 200 PSI Max Working pressure. 80 GPM Rating is with the lowest flow screen with no head loss. 200 PSI Max Working pressure.
More information3/4" BRASS AGRICULTURAL SPRINKLERS WR-33 WR-32 WR-35
3/4" BRASS AGRICULTURAL SPRINKLERS WR-33 WR-32 WR-35 NOTE: All sprinklers are double nozzle, but are shipped with the removable spreader nozzle plug installed and no range nozzle. All nozzles are ordered
More informationPRESS SWING CHECK VALVES. UPC NSF1-8 Double O-Ring Blow Out Proof Stem 250 CWP Max Temp: 300 F
PRESS 1 PRESS SWING HEK Lead Free ompliant One-Piece Body Design EPDM O-Ring Seal Heavy Pattern ast Brass Press Swing heck Valve One-piece body design EPDM o-ring seal Heavy pattern cast brass construction
More informationINSTALL MANUAL. FOR ON LINE ORDERING- E Commerce Visit Our Website
INSTALL MANUAL FOR ON LINE ORDERING- E Commerce Visit Our Website WWW.PRESSUREGUARD.COM Contact Information Technical Support: Chris@pressureguard.com Sales Support: Sales@pressureguard.com By Phone: 615-227-6024
More informationInde-Pendants Family. 32L Cylinder with Ring Chicago Plenum Ceiling Types. Document No
Inde-Pendants Family 32L with Ring Chicago Plenum Ceiling Types Installation instructions for: 32L-CRxx-P-ID-CCEA 32L-CRxx-P-D-CCEA Document No. 32L Inde-Pendants: with Ring (Plaster Trim, Grid and Drywall
More informationViking Installation Guide
iking Installation Guide iking Range orporation Front Street Greenwood, Mississippi 890 US (66) 455-00 For product information, call -888-IKING (845-464) or visit the iking Web site at vikingrange.com
More informationNETAFIM FLEXIBLE PIPES FLEXNET HP INNOVATIVE MAINLINE AND SUB-MAINLINE PIPING SOLUTIONS THAT ARE EASY TO INSTALL, RECOIL AND RELOCATE
NETAFIM FLEXIBLE PIPES INNOVATIVE MAINLINE AND SUB-MAINLINE PIPING SOLUTIONS THAT ARE EASY TO INSTALL, RECOIL AND RELOCATE APPLICATIONS For seasonal crop: Sub main for all drip irrigation and sprinkler
More informationPRODUCT MANUAL GEARCAGE SYSTEM - ASSEMBLY, INSTALLATION, AND OPERATION INSTRUCTIONS: Description
Gearage -FP6 Hitch Rack TwinTube ased Slide-Out Mounting System PROUT MNUL Installation & Safe Use Operation Highlights Fits 2 size receiver hitches. Rated for 300 lbs of cargo payload. lass II minimum
More informationUSER MANUAL. LP Unit 5000 PSI. HP Unit 7500 ALL - IN - ONE ALL - IN - ONE ALL - IN - ONE. 4" Drive Handles. LP Units Available in 12" Insertion Length
LP Unit 5000 PSI Flow Innovations MADE IN USA USER HP Unit 7500 PSI MANUAL Flow Innovations MADE IN USA ATOMIZER ATOMIZER COUPON HOLDER 4" Drive Handles COUPON HOLDER INJECTION QUILL INJECTION QUILL LP
More informationREAD AND SAVE MANUAL FOR FUTURE REFERENCE. Assemble your grill immediately. Missing or damaged parts should be claimed within 30 days of purchase.
SSEMLY MNUL uisinart Gourmet 600S 85-3078-6 (G41803) Propane 85-3079-4 (G41804) Natural Gas R ND SVE MNUL FOR FUTURE REFERENE. ssemble your grill immediately. Missing or damaged parts should be claimed
More informationMiniature Fittings Stainless Steel 316. Hose nipple. Barb. Configuration for easy insertion into the tube Holds the tube tightly.
iniature Fittings Stainless Steel 316 Series S RoHS Applicable Tubes: ø3.2, ø4, ø6 Connection Thread:, R 1/ For use in corrosive environments Compact piping space Tube has a large retaining force. Hose
More informationFire Protection Price List. Piping. Systems. Solutions A FP.
Piping. Systems. Solutions. Fire Protection Price List The Victaulic website is an information resource that can help you with your piping projects. Among the many resources available at the site: Fully
More informationTOYOTA TRUCKS / SUVs COLD AIR INTAKE Section I Installation Preparation. 4.0L V6 (1GR-FE) Part Number(s): PTR
Section I Installation Preparation Part Number(s): PTR05-35061 Kit Contents Item # Quantity Reqd. Description 1 1 Intake Tube 2 1 Air Filter Housing 3 1 TRD Air Filter w/ #096 clamp 4 1 Adapter, Filter
More informationInstallation Instructions
Important The Drinking Water Filter with MACguard will not make biologically unsafe water safe to drink since activated carbon will not kill bacteria. When applying the filter to non-chlorinated water
More informationSuspension Leveling Kits HIGH LOW REGULAR. .f. KT ASSEMBLY AND USAGE GUIDE
Suspension Leveling Kits LOW.f. REGULAR - HIGH t KT 192299 ASSEMBLY AND USAGE GUIDE INTRODUCTION ROCK RIDE Air suspension kits are designed to replace conventional steel springs or shock absorbers of your
More informationSINGLE WALL AL 29-4C SPECIAL GAS VENT
Straight Lengths: Saf-T Vent EZ Seal SINGLE WLL L 29-4 SPEIL GS VENT 6" Length Install vent with a continuous pitch of 1/4 per foot, sloping upward toward the termination, draining back Part Number DIM
More informationTABLE OF CONTENTS SPECIFICATIONS 3 INSTALLATION 4. Direct Mount 4. Ducted Installations 5. Installing Plenum 5. Machine Mount Stand 5.
TABLE OF CONTENTS PAGE SPECIFICATIONS 3 INSTALLATION 4 Direct Mount 4 Ducted Installations 5 Installing Plenum 5 Machine Mount Stand 5 Ceiling Mount 6 Pedestal Stand 7 Drain Installation 7 Electrical 8
More informationRA-20 Paint/Solvent/Dump Valve
Instruction Sheet P/N 74B0 RA-0 Paint/Solvent/Dump Valve Description The paint/solvent valve is a normally closed valve used to trigger coating material. The valve may be used alone to actuate paint or
More informationE Series Enclosures Installation Instructions (UL /UL2416 E Series Equipment Cabinet/Rack)
E Series Enclosures Installation Instructions (UL60950-1/UL2416 E Series Equipment Cabinet/Rack) WeRackYourWorld.com 1-866-TRY-GLCC (879-4522) Instructions for the following Great Lakes Enclosures: GL720E-2432,
More informationSchedule 40 Fittings & Accessories Turf Swivel Joints
Turf Swivel Joints Turf Swivel Joints, Compact Turf Swivel Joints and Turf Swivel Joint Kits are designed for open discharge systems and are not to be used with valve-in-head sprinklers or quick coupler
More informationHigh-Flow Stainless Tubes. Standard Tubes BRASS 18 LONG STAINLESS STEEL 18 LONG H11. All stainless construction for high strength and durability
High-Flow Stainless Tubes H11 ll stainless construction for high strength and durability Use with all PCS cascades J in part number indicates next largest thread TUE TUE L = 12 18 24 36 HF093T-.090.076
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS Part # 751-FP2500 IMPORTANT INFORMATION This Jagg oil cooler must be installed following these instructions. Read the easy-to-follow instructions fully prior to starting the installation
More information1 1/4 NPT FILTER SIZE DESIGNATION PRICE 2 NPT FILTER REPLACEMENT SCREENS FOR 1 1/4 & 2 FILTERS 1 1/4 SCREENS 2 SCREENS HOLE SIZE DESIGNATION PRICE
ALUMINUM Y FILTERS 50 GPM Rating is with the lowest flow screen with no head loss. 200 PSI Max Working pressure. 80 GPM Rating is with the lowest flow screen with no head loss. 200 PSI Max Working pressure.
More informationPipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.
Signet 50 High Performance Flow Sensor English *3-50.090* 3-50.090 Rev. F 11/1 English For the most up-to-date information, please refer to our website at www.gfsignet.com SAFETY INSTRUCTIONS 1. Do not
More informationSection 8. Copper Series
Section 8 opper Series Grooved ouplgs, Fittgs & omponents for opper Tubg... 164 Pressure Ratgs of opper Tubg... 164 Standard Roll Groove for U.S. Standard opper Tubg... 164 Grooved ouplgs & Flanges for
More informationFast-Flo Pump INSTRUCTIONS-PARTS LIST. Table of Contents 1:1 RATIO
INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. First choice when quality counts. 07 7 Rev. Z Supersedes W Includes Rev. Y changes
More informationMULTI-JET WATER METERS
MULTI-JET WATER METERS INSTALLATION INSTRUCTIONS General Information Technical Data 3 Features 3 Applications 3 Dimensions 3 Pulse Rate 3 Pressure Loss Curve 3 Shipping Weight 3 Installation Position 4
More informationFLUID POWER FLUID POWER EQUIPMENT TUTORIAL PIPE WORK. This work covers part of outcome 2 of the Edexcel standard module:
FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PIPE WORK This work covers part of outcome 2 of the Edexcel standard module: UNIT 21746P APPLIED PNEUMATICS AND HYDRAULICS The material needed for outcome 2 is
More informationGeneral Information. Assembly Instructions B L R F. 3000TM Fold Assist Kit
Fold Assist Great Plains Manufacturing, Inc. 000TM Fold Assist Kit General Information These Instructions explain how to install the fold assist kit update. This update only applies to the 000 Turbo Max.
More informationTL960 PARTS MANUAL. Fuel Section. Page 9-1. Fuel 09/97
Fuel Section Fuel Page 9-1 Fuel Tank Between The Rails Page 9-2 Fuel Fuel Tank Between The Rail Item Part Num. Number Qty. Description Notes 1 61360662 1 Elbow, 90 o, 1/2" NPT x 5/8" T 2 61270100 1 Sender
More informationCENTRO-MATIC PUMP, MODELS 84050, & 85460
CENTRO-MATIC DEC - 2006 Section - C8 - C8 Page - 142S Table of Contents Page Safety...2 Specifications...2 Description...2 Pump Operation...2 Installing the Pump...2 Optional Devices......3 Puffing Pump
More informationQuicklub Lubrication Systems Fittings, Adapters and Accessories
Divider Valve Mounting Accessories 246416 Valve mounting bracket 51304 ¼" nylon locknut for valve mounting 247023 Grade 8, ¼" valve mounting bolt 239499 Template for divider valve mounting (6, 8, 10 and
More informationONE TOUCH FITTINGS Series WP2
ONE TOUCH FITTINGS - M5 1/ 1/ 3/ 1/2 Features Attractive design Compact size ed nipples of L, T & Y fittings enable plastic portion to turn by 30º Full area of the inner bore of the tubing is available
More informationMODEL VFF30 REPAIR KIT INSTALLATION INSTRUCTIONS
INSTALLATION SAFETY PRECAUTIONS: 1. Do NOT use Teflon thread tape on any of the NPT pipe-thread fittings where fuel travels. Use a suitable fuel-resistant joint compound. 2. Be sure to leak-check all fittings
More information