OmniLogic Main Circuit Board (HLX-PCB-MAIN)
|
|
- Virginia Welch
- 5 years ago
- Views:
Transcription
1 b20v3 OmniLogic Main Circuit Board (HLX-PCB-MAIN) Pg.1
2 OmniLogic: Component Description **Click On Component To Advance** A E D F G H Z X Y W B J L M I N T U V C K O P Q R S Pg.2 A Sensor Blocks (SENS 1-4) N High Voltage Relay Port (HVR 1-4) B Low Voltage Relays (LVR 1-4) O High Voltage Relay 9 & 10 Ports (HVR 9 (Left) & 10 (Right)) C Valve Actuator Ports (VLV 1-4) P (2) 20 Amp Fuse (Surge Protection) D (2) Smart Component Comm Ports Q (1) 5 Amp Fuse Prevents Board Overdraw) E (2) RS485 Comm Terminal Blocks R 120 AC into the board (From Breaker) F (3) High Speed Buses S 120 AC to Power Supply G (1) High Speed Terminal Block T Rectifier Input/output AC to DC (Cell Circuit) H 4 Amp Fuse (Protects Valve Actuator Circuit) U 20 Amp Fuse (Protects the Cell Circuit) I MSP Power and Comm Port (Local Display) V Transformer Output (Cell Circuit) J Flow Switch Ports (FLOW SWITCH 1-2) W DC Output from Power Supply (Board Function Power) K Turbo Cell Female Receptacle (CHLR1) X 4 Amp Fuse (Protect the Transformer - Cell Circuit) L WiFi Antenna LAN Power (HLWLAN) Y Transformer Input (Cell Circuit) M Relay Bank Port (HVR 5-8) Z I/O Expansion Socket (For I/O Expansion Card)
3 OmniLogic: (A) Sensor Block & (B) LVR Block +3.3VDC +3.3VDC +3.3VDC +3.3VDC +3.3VDC Dry Contact Dry Contact Dry Contact Dry Contact Pg.3
4 OmniLogic: (C) Valve Actuator Circuit ON VLV4 +24VAC OFF VLV3 +24VAC ON VLV2 SUCTION +24VAC OFF VLV1 RETURN +24VAC PCB *Default State is OFF **Note: These circuits are susceptible to shorting. It is recommended to test with the actuators plugged in; if this is not an option extreme care should be used to avoid shorting pins when testing these circuits. Pg.4
5 OmniLogic: (D) Smart Component Comm Ports & (E) RS485 Comm Terminal Blocks COMM BUS COMM BUS +12VDC +12VDC PCB USE: Sense & Dispense Color Logic Module COMM BUS Port Description 1 +12VDC 2 tx (Data) 3 rx (Data) USE: Variable Speed Pumps Pg.5
6 OmniLogic: (F) High Speed Buses & (G) High Speed Terminal Block HS BUS +12VDC PCB HS BUS HS BUS +12VDC +12VDC USE: Wired Remotes & Expansion Panel Comm Port Description 1 +12VDC 2 tx (Data) 3 rx (Data) 4 USE: Wired Remotes & Expansion Panel Comm. 5 COMMON Pg.6
7 OmniLogic: Fuses (H) 4amp, (P) 2x 20amp, (Q) 5amp, (U) 20amp, (X) 4amp H P X U Q H P Q U X 4 amp fuse designed to protect the actuator circuit. (2) 20 amp fuses designed the protect the board from an electrical event (such as a heavy voltage spike). 5 amp fuse designed to protect the circuit incase the board draws more than 5amps due to equipment failure. 20 amp fuse designed to protect the Chlorinator circuit. 4amp fuse designed to protect the Transformer (used for chlorination and valve actuator power). Pg.7
8 OmniLogic: (I) MSP Power & (L) WiFi Antenna LAN Power +12VDC +24VDC FOR WiFi Power FOR MSP (Display) *Note: These circuits are susceptible to shorting. It is recommended to test on the cables; if this is not an option extreme care should be used to avoid shorting pins when testing these circuits. Pg.8
9 OmniLogic: (M) Relay Bank Port, (N) HVR Port 1-4 & (O) HRV 9+10 RELAY BANK HV BANK Communication +25VDC HV9 HV10 *Note: These circuits are susceptible to shorting. It is recommended to test directly on the low voltage side of the relay; if this is not an option extreme care should be used to avoid shorting pins when testing these circuits Pg.9
10 OmniLogic: (R) 120AC Main Power IN & (S) 120AC to Power Supply OUT From Breaker 120VAC NEUTRAL *Test on white connector To Power Supply (PSU) 120VAC 120VAC *Test on red connector Pg.10
11 OmniLogic: (T) Rectifier Output, (V) Transformer Output & (Y) Transformer Input Transformer Supply From Board (Formerly Blue, White, Violet and Grey) NEUTRAL 120VAC NEUTRAL 120VAC Transformer Output Total 24VAC 24VAC Rectifier Input (Orange) & Output (Red/Black) 24VAC 12VDC 12VDC Pg.11
12 OmniLogic: (W) DC Output from Power Supply & (Z) I/O Expansion Socket Z W W USE: DC power off Power Supply (for most board functions). +24VDC +12VDC Z USE: Communication to an I/O Expansion card for 4 additional valves, low voltage relays and sensors. Pg.12
OnCommand Troubleshooting Guide Hayward Industries
OnCommand Troubleshooting Guide 2010 Hayward Industries Table of Contents Safety Precautions Page 1 Overview Pages 2-5 Software Troubleshooting Page 6 Local Display Pages 7-8 Relays Pages 9-10 Heaters
More informationAutomation & Sanitization REPLACEMENT PARTS
& Sanitization PROLOGIC GLX-PS-AQC Main PCB-PRO ProLogic with AquaConnect Bundle GLX-PCB-PRO* Main PCB, ProLogic GLX-PL-LOC-P-4 Display, Local, ProLogic, P-4 GLX-PL-LOC-PS4 Display, Local, ProLogic, PS-4
More informationGCL-GT HEAVY-DUTY GEAR HEAD TROLLEY OPERATOR
GCLGT HEAVYDUTY GEAR HEAD TROLLEY OPERATOR Single Phase MODULE MOUNTING LOCATIONS TROUBLE SHOOTING LEDs BOARD PORT LIMIT SENSOR HOIST MOTOR S GROUND NOT FOR RESIDENTIAL USE 208/230V 1PH 115V 1PH ROUTE
More informationELSEMA 240VAC Slider Control Board, SLD
SLD Slider Control Board ELSEMA Features For Single 240VAC Motor Built-in transformer, auto close, open only, security close & special security close Application Control an automatic door or gate with
More informationFigure 3-9. Right-Hand Port Connector Configuration. 1. Remove electrical power to the Hydraulic Control Unit.
Figure 3-9. Right-Hand Port Connector Configuration Extend and Retract Limit Switch Configuration (if required) 1. Remove electrical power to the Hydraulic Control Unit. WARNING: DO NOT REMOVE OR INSTALL
More informationIRRIGATION 810-3T-PLUS TRANSMITTER GUIDE
IRRIGATION 810-3T-PLUS TRANSMITTER GUIDE Pg. 2 HOT SHOT OVERVIEW 3 STANDARD OPERATION MODE 4 HOW TO CONTROL AND SHARE MULTIPLE S 5 TRANSMITTER FUNCTION SWITCH SETTINGS 6 OPERATING THE TEST BEACON 7 OPERATING
More informationPOOL PILOT PROFESSIONAL
POOL PILOT PROFESSIONAL PRO2US: Professional System 78102A Professional Unit with 2 Power Modules 941-215AC Professional Manifold 2-Cells PRO6US: Professional System 78106A Professional Unit with 6 Power
More informationProLogic /AquaLogic. Troubleshooting Guide Residential. TSG-PL447b. Copyright 2016 Hayward Industries Inc.
ProLogic /AquaLogic Troubleshooting Guide Residential TSG-PL447b Copyright 2016 Hayward Industries Inc. Safety Precautions Warning! High Voltage Electrocution Hazard Hazardous voltage can shock, burn,
More informationSingle or Double 240VAC motor control for domestic and industrial gates and doors.
COBO30 Double 240V Motor Drive Controller Features For 240Volt Motors Auto Closing Open Only Security Closing and Extended Lock Pulse (user selectable) Travel Timer Push Button Input Photo Cell Input Option
More informationFM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017
FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017 Maxi-Tronic, Inc. 417 Wards Corner Road Loveland, OH 45140 513.398.2500 800.659.8250 FAX: 513.398.2536 info@maxitronic.com
More informationELSEMA Single / Double Gate Controller, for 12V / 24V Motor, GATCO12S, GATCO24S, GATCO12D, GATCO24D
GATCO12S, GATCO24S, GATCO12D, GATCO24D Single / Double Gate Controller, for 12V / 24V Motor Features 4 Versions: 12V / 24V Single / Double Motor Application Control an automatic door or Gate GATCO12S 12V
More informationTECHNICAL DATA SHEET KVA UPS Systemss
Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800
More informationINSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBER
TO-161 073085 INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBER 6184-3..-.-.._. HOBART BROTHERS COMPANY Power Systems Division Troy, Ohio 45373
More informationTo ensure proper installation, digital pictures with contact information to before startup.
Check List for Optimal Filter Performance [ ] There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing
More informationPOOL PILOT PROFESSIONAL
POOL PILOT PROFESSIONAL PRO2US: System 78102A Unit with 2 Power Modules 941-215AC Manifold 2-Cells PRO6US: System 78106A Unit with 6 Power Modules 941-615AC Manifold 6-Cells PART # PRO2US PRO3US PRO4US
More informationINSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBERS
081385 INSTRUCTIONS FOR REMOVAL OF GROUND FAULT PROTECTION DEVICE FROM HOBART GENERATOR SETS SPECIFICATION NUMBERS 6184-2 HOBART BROTHERS COMPANY Power Systems Division Troy, Ohio 45373 INSTRUCTIONS FOR
More informationSeries BFM Bulk Flow Monitor 1A FUSE RED LED RELAY. Part Number BFM-1 BFM-2 BFM-3 BFS-1
Series Bulk Flow Monitor Specifications - Installation and Operating Instructions Bulletin FL-1-4x 3/4 CONDUIT KNOCKOUTS BFS 1A FUSE RED LED RELAY 5-9/64 [130.45] TRANSFORMER 3[76.20] GREEN LED 7 [177.80]
More informationThis chapter contains information on DC Generation, External Power, and Electrical Load Distribution.
CIRRUS AIRPLANE MAINTENANCE MANUAL Electrical Power CHAPTER 24-00: ELECTRICAL POWER GENERAL 24-00: ELECTRICAL POWER 1. General This chapter contains information on DC Generation, External Power, and Electrical
More informationSwitchgear Skid, C1192
CUSTOM SOLUTIONS 15kV Modular Stairs stored on floor in front of battery bay Ground grid stored on front tongue of trailer Stairs deployed for unit access Storage box for fencing materials and other parts
More informationUSER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply
www.eaton.com/dxups USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply CONTENTS 1.Brief introduction 1 1.1 System and model description 1 1.2 Description of commonly used symbols
More informationProLogic Controls. Line Reference Item No. Description Sugg. List
ProLogic Controls W000543.00 GLXPCBPRO Main PCB, ProLogic $1,086.00 W000343.80 l GLXPLLOCP4 Display, Local, ProLogic, P-4 $687.60 W000447.00 l GLXPLLOCPS4 Display, Local, ProLogic, PS-4 $894.00 W000551.80
More information0500 Low Voltage on the Battery or Dead Cell in the Battery
0500 Low Voltage on the Battery or Dead Cell in the Battery Whenever you press the remote transmitter and you get one short beep from the control box, you press the remote and hear a warning buzzer but
More informationCover. L5v2 Plug-In Conversion Module(PCM) Diagnostic Trouble Codes
Cover L5v2 Plug-In Conversion Module(PCM) Diagnostic Trouble Codes Copyright 2009 A123 Systems, Inc. All rights reserved DOCUMENT NOTICE: The information contained in this manual is the property of A123
More informationABB - DMPC PG Solar, Nov 2016 ABB: a leading company in solar The most comprehensive value proposition
ABB - DMPC PG Solar, Nov 2016 ABB: a leading company in solar The most comprehensive value proposition ABB in solar: most comprehensive value proposition Remote control and monitoring Global sales and
More informationZipLink Ready to Wire Pigtail Cable Installations
ZipLink Ready to Wire Pigtail able Installations Ziplink readytowire pigtail cables allow the use of Ziplink Modules (FeedThrough, Fuse, Relay, or LED versions, either or channel) with any brand of PL.
More informationPOWER kva
TECHNICAL DATA SHEET B9000 FXS 60-80-100-125-160kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos φ 0,8) kva 60 80 100 125 160 Nominal output power
More informationilevil 2 AW Wireless Integrated Avionics Module AD-AHRS, GPS, ADS-B 978 / 1090 MHz Receiver Instruction Manual
ilevil 2 AW Wireless Integrated Avionics Module AD-AHRS, GPS, ADS-B 978 / 1090 MHz Receiver Instruction Manual ilevil 2 AW ADS-B ANTENNA GPS ANTENNA STATIC PRESSURE DYNAMIC PRESSURE ON/OFF SWITCH CHARGING
More informationSE2000BX Static Exciter
Rev 3 SE2000BX Static Exciter The SE2000BX Static Exciter is designed to replace most electronic, saturable reactor and rotary exciters used on slip ring or rotor fed electric generators. The SE2000BX
More informationLB LOAD BANK MANUAL CONTAINS OPERATING INSTRUCTIONS PARTS LIST WIRING DIAGRAMS SERVICE INSTRUCTIONS
LB-60-30 LOAD BANK MANUAL CONTAINS OPERATING INSTRUCTIONS PARTS LIST WIRING DIAGRAMS SERVICE INSTRUCTIONS 4031 W Kiehnau Ave Milwaukee, WI 53209 CAUTION THIS LOAD BANK IS DESIGNED FOR THE TESTING AND SERVICING
More information3 Slot Payphone Controller
S Coin Controller 2A Information on your Telephone For Your Records Manufacturer Date of Original Manufacture Drawing Reference One of the original patents --- US 2,043,201 This Telephone is Property of
More informationExplanation 1 Input External Switch 2 Input Hipot Safety Switch
on the 1100H+ The 1100H+ has capability, which allows you to set up the tester to control external devices with tester functions. You can also use an input on the tester to start a test. For example, the
More informationInstallation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor
World Leader in Modular Torque Limiters Installation and Maintenance Instructions PTM-4 Load Monitor 1304 Twin Oaks Street Wichita Falls, Texas 76302 (940) 723-7800 Fax: (940) 723-7888 E-mail: sales@brunelcorp.com
More informationDoorway Foamer. Packers Chemical 3729 Peddle Hollow Rd Kieler Wi, Phone Fax
Doorway Foamer Packers Chemical 3729 Peddle Hollow Rd Kieler Wi, 53812 Phone 608.568.3841 Fax 608.568.7582 Doorway Foamer SAFETY As with any equipment of this type, when electricity and chemicals are involved,
More informationPOWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)
TECHNICAL DATA SHEET B9000 FXS 200-250 - 300kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE - Double Conversion Nominal output power (Cos φ0,8) kva 200 250 300 Nominal output power (Cos φ1,0)
More informationFUEL MANAGEMENT SYSTEM SentryGOLD INSTALLATION MANUAL
FUEL MANAGEMENT SYSTEM SentryGOLD INSTALLATION MANUAL TRAK SentryGOLD Installation Manual rev.03 4-18-2014 IMPORTANT The SentryGOLD and associated equipment will be installed in close proximity to combustible
More information3 Installation of Display Unit > 3.5 Installation of Option Equipment
W853:H-7ZCNA4160(included in CML-836-DC) Connect the W853 cable connector labeled P51 to the J51 connector on the PSU. Connect the W853 cable connector labeled P839 to the J839 connector on the RIF. Co-tighten
More informationWiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Figure Number. Label Diagram No. 30HX ALL ALL
Wiring Diagrams 30HXA, 30HXC Condenserless and Fluid-Cooled Chillers 50/60 Hz DIAGRAM INDEX POWER SCHEMATICS Unit 30HXA,C Voltage Figure Number Label Diagram No. 30HX 076-186 ALL 1 500141 206-271 ALL 2
More informationPOWER kva
+44 (0)20 8868 3732 TECHNICAL DATA SHEET B9600 400-800kVA GENERAL INFORMATION UPS Type ON LINE - Doppia Conversione Nominal output power (Cos φ0,8) kva 400 500 600 800 Nominal output power (Cos φ1,0) kw
More informationPower Switching Devices
Watlow has manufactured solid state power controllers for over forty years. Watlow s is a microprocessor-based product that features application flexibility unmatched by any other silicon controlled rectifier
More informationShaved-B. Installation Manual & Operation Instructions
Shaved-B Installation Manual & Operation Instructions Each Kit Contains The Following Components (1) Receiver (2) Remotes (2) Wire Harnesses Installation Instructions for SPAL Shaved Door Handle Kit Shaved-40
More informationFILE # 220V TO 120V CONVERTER
14 February, 2018 FILE # 220V TO 120V CONVERTER Document Filetype: PDF 367.79 KB 0 FILE # 220V TO 120V CONVERTER JRing 240V Mains To 12V DC Cigarette Lighter Voltage Converter Power Adapter (10A). What
More informationG-Series. Circuit Breaker.
-Series Circuit Breaker Carling Technologies -Series hydraulic/magnetic circuit breakers offer the highest quality solution to your circuit protection requirements. The -Series is designed to sense over-current
More informationMODEL POWER BATTERY VOLTAGE COMMUNICATION. LBC SxxxG* 8000 W 110 V CAN or Ethernet. LBC SxxxG* W 110 V CAN or Ethernet
The shelf consists of a ruggedized Battery Charger, PSU with a 3-phase input for 400 / 480 VAC (line to line) and with an output suitable for 110V battery charging. DC-DC stage to convert the 3-phase input
More information1VAL2401-SG Rev D. Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches
1VAL2401-SG Rev D Spare parts list for Outdoor Products Reclosers, breakers, & padmount switches Reclosers GridShield recloser 12A00736H05 Actuator assist capacitor Single-phase upgrade 15 KV, 800 A, 12.5
More informationAQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2
AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2 INTRODUCTION The Aquavar Intelligent Pump Controller from utilizes an all new Aquavar platform, and combines it with over 20 years of
More informationParts Catalog TECHNICAL DOCUMENTS TABLE OF CONTENTS. Electric. Other. Non-electric
TECHNICAL DOCUMENTS Parts Catalog TABLE OF CONTENTS Electric Pumps... 2 Compressors.... 3 Fans.... 3 Valves... 3 Pressure switches.... 4 Dial pots and switches... 4 Breakers and fuses.... 5 Transformers....
More informationU n i n t e r r u p t i b l e P o w e r S y s t e m
SMART ON-LINE UPS User s Manual U n i n t e r r u p t i b l e P o w e r S y s t e m Smart On-Line UPS 2KVA ~ 20KVA 20KVA Exhaust hole (16)Main breaker (12)Heat exhaust hole (15)Telephone (Rj11) or network
More informationGLM SERIES CONTROL Users Manual Rev:
GLM SERIES CONTROL Users Manual Rev: 808062 Connecting Power Page 2 Motor Terminal Wiring Diagrams Page 3 Getting Started / Setup Page 4 1. Obstruction Detection Devices Page 4 2. Checking Power and Direction
More informationOWNER'S OPERATING MANUAL
OWNER'S OPERATING MANUAL SG Series UPS Plus Uninterruptible Power Supply Models: SG5K-1TX, SG5K-1TXC, SG5K-X1T SG5K-2T. SG5K-2TC, SG5K-X2T SG5K-2TX, SG5K-2TXC, SG5K-X2TC, SG6K-1TX, SG6K-X1T SG6K-2T, SG6K-X2T,
More information24 ELECTRICAL DC ELECTRICAL SYSTEM DESCRIPTION
24 ELECTRICAL DC ELECTRICAL SYSTEM DESCRIPTION The Direct Current electrical system provides power to most equipment through an electrical bus system. The power may be supplied from one of three sources:
More informationIllustrated Parts Guide DSD EDGE 120VAC. Page 1 of 32
Illustrated Parts Guide DSD EDGE 120VAC Illustrated Parts Guide Page 1 of 32 This document is designed to provide a quick reference to the major replacement parts and components for the DSD EDGE. Parts
More information24-00 ELECTRICAL POWER
ELECTRICAL POWER 1. GENERAL This chapter contains information on DC Generation, External Power, and Electrical Load Distribution. The airplane is equipped with a two-alternator, two-battery, 28-volt direct
More informationParts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)
Parts Manual Transfer Switch 50/225/260 Amps OTPCB (Spec A) English Original Instructions -203 962 0228 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation
More informationCP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 Comm Metr PDSTL Milbank MFG. Catalog Number Manufacturer Description Weight per unit Product Category Descriptions Long
More informationAssembly Manual for ISDR-136-KIT
Assembly Manual for ISDR-136-KIT ICAS Enterprises Last Updated March 21 st, 2012 This SDR receiver kit is intended for the 136kHz band. The kit utilizes DIP IC components (no SMD) so that even a beginner
More informationParts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)
Parts Manual Transfer Switch 00/00/600 Amps OTPCC (Spec A) English Original Instructions -20 962 0229 (Issue ) This catalog covers models produced under the Cummins /Onan and Cummins Power Generation brand
More informationInstallation Instructions
SPECIFICATIONS v2 Fixture Mount Power Pack Model: Fixture Sensor Power Pack V2 120/277/347VAC, 60Hz @347VAC 3.4A () 2A () Power...120/277/347VAC, 60Hz Relay Type... Form C with Zero Crossing on N.O. only
More informationLED Drivers A Practical Understanding for Lighting Applications. Dr. Adan Hernandez, Philips-Advance Al Marble, Philips-Advance
LED Drivers A Practical Understanding for Lighting Applications Dr. Adan Hernandez, Philips-Advance Al Marble, Philips-Advance Outline What is a driver? Design types Constant current vs. constant voltage
More informationContinuing Education Course #206 Introduction to Designing Machine Control Systems Part 2
1 of 5 Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2 1. Continuing to answer the following questions indicates that you understands that the presented material
More informationUninterruptible Power System
USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS AVR Protection
More informationParalleling Equipment
Paralleling Equipment PowerCommand Model 300 Digital Master Control Description The PowerCommand TM Digital MasterControl is a microprocessor-based paralleling system component, designed to directly interface
More informationTECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)
TECHNICAL DATA SHEET B8033FXS 10 15 20 kva 3Ph(In) 3Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cosϕ 0.9) kva 10 15 20 Nominal output power (Cosϕ 1.0) kw 9 13.5
More informationJRVCS105 TROUBLESHOOTING GUIDE
JRVCS105 TROUBLESHOOTING GUIDE This guide is made to ease troubleshooting the in-command system. It will cover the wiring code and where those wires are connected to the Body Control Module (BCM) and Display
More informationBrake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.
Standard AC SB5W Standard AC Intro duction Induction Reversible Right -Angle Gearheads SB5W AC Speed Control Inverter SB5W US ES2 FE1/FE2 Watertight, Dust-Resistant Torque Accessories Installation A-143
More informationCHAPTER 24 - ELECTRICAL POWER TABLE OF CONTENTS
ELECTRICAL POWER 24-00 General 1 Electrical Power - Serials w/o Perspective Avionics 1 Electrical Power - Serials w/ Perspective Avionics 1 Troubleshooting 2 DC GENERATION 24-30 Description 1 DC Generation
More informationQuick Installa on Guide. For SK-SU.
Quick Installa on Guide For SK-SU www.solaxpower.com Grid ed storage inverter (SK-SU) Grid ed charger (SK-BMU) Object A B C D E F G H I J K L M Description DC switch DC connector area Ethernet connector
More informationPowerCommand iwatch Wireless
PowerCommand iwatch Wireless Description The PowerCommand iwatch Wireless remote monitoring system provides a simple, inexpensive method for remotely monitoring gensets. The monitor communicates with a
More informationSilver T E L E C O M. 1. Features. 2. Description. IEEE802.3af compliant. Small SIL package size - 56mm (L) x 14mm (H) Low output ripple and noise
Silver T E L E C O M V2.0 Aug 2008 Pb. Features IEEE802.3af compliant Small SIL package size - 56mm (L) x 4mm (H) Low output ripple and noise Input voltage range 36V to 57V Only one low cost external decoupling
More informationTECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)
TECHNICAL DATA SHEET B8031 FXS 10 15 20 kva 3Ph(In) 1Ph(Out) GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos 0.9) kva 10 15 20 Nominal output power (Cos 1.0) kw 9 13.5
More informationOPERATING MANUAL BDP600 UNIVERSAL BATTERY DISTRIBUTION PANEL
BDP600 UNIVERSAL BATTERY DISTRIBUTION PANEL www.unipowerco.com Manual No. BDP600-2 bdp600-man-rev2-0416.indd 2016 UNIPOWER LLC All Rights Reserved NORTH AMERICA 3900 Coral Ridge Drive, Coral Springs, Florida
More informationELSEMA Single / Double Gate Controller, with Battery Charger, for 12V / 24V Motor, Enclosed, GATCOxxxCH
GATCO12SCH, GATCO24SCH, GATCO12DCH, GATCO24DCH Single / Double Gate Controller, with Battery Charger, for 12V / 24V Motor Features 4 Versions: GATCO12SCH 12V Single motor GATCO24SCH 24V Single motor GATCO12DCH
More informationINTECH Micro 2300-RTD6
INTECH Micro 2300-RTD6 6 Channel RTD Input Station Overview. The Intech Micro 2300 Series is a system of modular I/O Remote Stations, that add an even lower cost option to Intech s already extensive intelligent
More informationINSTRUCTIONS. DO NOT CONNECT TO MAINS POWER ( V AC).
P.O Box 578 Casino, NSW, 2470 Australia Phone: International ++614 2902 9083 Australia (04) 2902 9083 Website: http://rcs-rc.com E mail: Info@rcs-rc.com ALPHA-3v2 Electronic Speed Controller Supplied for
More informationPivot Point Lite Wiring Manual
2009-10 Pivot Point Lite Wiring Manual (small square single circuit board design) Section 1 Pages 2-3 Pivot wiring to monitor and/or stop the irrigation system. Section 2 Page 4 Section 3 Page 4 Simple
More informationEnterra /Eclipse Junior/Interra VLC Curing Unit
Enterra /Eclipse Junior/Interra VLC Curing Unit Service Manual Model Number Voltage Frequency 9495100/9495102/9495400 100-120V 50-60Hz 9495101/9495151/9495401 200-240V 50-60Hz TABLE OF CONTENTS Safety...2
More informationGLMB209DBC GLMB209DQC GLMB209DSC PLMB209DCD
Product No. GLMB209DBC GLMB209DQC GLMB209DSC PLMB209DCD Market North America North America North America North America Color black bisque white stainless steel Volts 120 120 120 120 Watts 1200 1200 1200
More informationTable of Contents. 350 V, 80 kw, 20 kwh, traction battery pack, specifications
350 V, 80 kw, 20 kwh, traction battery pack, specifications Table of Contents 1 Description...2 2 Block diagram...3 3 Electrical Specifications...4 Pack...4 Charger...5 DC-DC converter...5 4 Mechanical
More informationSOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet
SOLAR SMART 12/24V 20Amp MPPT Solar Charge controller with Ethernet Embedded web pages, SNMP support, output port for external Relay board and GSM SMS unit port USER MANUAL PLEASE READ THIS MANUAL CAREFULLY
More informationUsers Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B
Users Manual Defender 1 8.0KW to 14.0KW Online Lighting Inverter Technical Manual #018-0102-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail:
More informationUsers Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B
Users Manual Cobra Plus Stand-By Lighting Inverter Technical Manual #018-0110-01 Revision B Phone: 1.877.DSPM.POWER 1.877.377.6769 Fax: 909.930.3335 Website: www.dspmanufacturing.com E-Mail: techsupport@dspmanufacturing.com
More informationLBC S102G 8000 W Ethernet CAN bus on request. LBC S101G W CAN bus Ethernet on request
The shelf consists of a ruggedized Battery Charger, PSU with a 3-phase input for 400 / 480 VAC (line to line) and with an output suitable for 110V battery charging. DC-DC stage to convert the 3-phase input
More informationTECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)
TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power
More informationUser Manual V1.1 OptiFlex 1100 / OptiFlex 2000
User Manual V1.1 OptiFlex 1100 / OptiFlex 2000 Uninterruptible Power Supply System Table of Contents 1. Important Safety Warning 2 1-1. Transportation 2 1-2. Preparation 2 1-3. Installation 2 1-4. Operation
More informationSola 3000 Guide Specifications
Sola 3000 Guide Specifications CSI 16610 - Static Uninterruptible Power Supply Systems - Sola 3000 Guide Specifications for a 700 to 2200 VA Single - Phase Uninterruptible Power Supply System 1.0 GENERAL
More informationUnpack. Left Handing (L) the Operator. StrongArmPark DC Breakaway Bracket Installation Video
DC Left Handing (L) Standard. Factory ships left handing operator. NOTE: If your site requires right handing, place the order with your distributor as a StrongArmPark DC with right handing. Handing changes
More informationBT300 HVAC Drives Conventional Bypass (C-Bypass) Options
BT300 HVAC Drives Conventional Bypass (C-Bypass) Options Description The BT300 Conventional Bypass is a companion package for the family of BT300 HVAC Drives. For information on the family of BT300 HVAC
More informationmagellan commercial UPS solutions Magellan Power Modular - Flexible UPS
magellan commercial UPS solutions Magellan Power Modular - Flexible UPS Commercial UPS Solutions 2 MPM3320-60kVA MPM3320-100kVA MPM3320-200kVA MPM3340-400kVA MPM3340-520kVA 2015 W www.magellan-power.com.au
More information1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8
Contents : 1. INTRODUCTION...1 2. IMPORTANT SAFETY INSTRUCTIONS...2 3. SYSTEM DESCRIPTION...4 3.1 Front Panel...4 4. CONNECTION AND OPERATION...6 5. TROUBLESHOOTING...8 6. MAINTENANCE...9 6.1 Operation...9
More informationDC TO AC POWER INVERTER
DC TO AC POWER INVERTER 12V / 24V / 48Vdc Input 115V / 230Vac Output 150W ~ 6000W Output cont. L-Series User Manual Before install and use your Inverter, read the User Manual and safety instructions. Cooler
More informationFIRE DOOR OPERATOR WARNING INSTALLATION LOGIC BOARD REPLACEMENT KIT K , K A-400 & K B-400 APPLICATION REMOVE AC AND DC POWER
APPLICATION Replacement of logic board for Models FDO and FDC operators with Rev. 400 wiring. FIRE DOOR OPERATOR LOGIC BOARD REPLACEMENT KIT K79-3493-400, K79-3493A-400 & K79-3493B-400 WARNING To prevent
More informationWEM-MX-333mV. Integrated Meter Installation Guidelines
WEM-MX-333mV Integrated Meter Installation Guidelines Energy Tracking, LLC Dated: February 8, 2013 By: Support Staff Table of Contents Enclosure Mounting... 2 High Voltage Wiring Type... 4 High Voltage
More informationModel PRO9801C Installation Manual
Model PRO9801C Installation Manual SELECTABLE FEATURES The selectable features can be set manually as explained below, with the RF feature programmer. To set features using the RF programmer, follow the
More informationXtalin Accumulator Monitoring System and. Xtalin Accumulator Balancing System devices
www.xtalin.com lagler@xtalin.com Xtalin Accumulator Monitoring System and Xtalin Accumulator Balancing System devices Datasheet - Public Table of content 1. List of abbreviations... 4 2. List of all AMS
More informationInstalling a Programmed Fronius SCERT in a Managed AC Coupled system
Installing a Programmed Fronius SCERT in INTRODUCTION This document is included with Fronius SCERT PV Inverters that have been programmed. It applies only to units that have been programmed and are ready
More informationPosi-Lok Plugs and Panels
FEMALE PANEL PART NUMBERS RECEPTACLES PER PANEL FEMALE PANELS COVER COLOR CODE 3 E0400-1685 GR, WH, BK 4 E0400-1686-NN GR, BK, RD, BU 4 E0400-1696 GR, WH, BK, RD 4 E0400-1883-NN GR, BRN, ORG, YEL 5 E0400-1687
More informationTECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III
TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III 1. SCOPE A. The Central Lighting Inverter shall be a solid-state three phase system designed to provide
More informationG3 PRIMO CAPPUCCINO SYSTEMS
G3 PRIMO CAPPUCCINO SYSTEMS TROUBLESHOOTING GUIDE MODELS: PCGT3, PCGT4, PCGT5, PCGT6 PCGT3 PARTS IDENTIFICATION FRONT VIEW CHASSIS VIEW HEATING TANK VIEW 3 18 19 5 4 20 22 1 2 11 12 13 14 8 9 10 15 16
More informationDART Charger Product Description, Information and Specification
g Digital Energy DART Charger Product Description, Information and Specification Document Number : PRPI-029 Version : 1.00 Revision : 2 Date : 03.02.11 Classification: NOTICE OF COPYRIGHT & PROPRIETARY
More informationModel AS-9234E. Table Of Content: of 32. Installation Manual Vehicle Security System With Remote Start
Model AS-9234E Installation Manual Vehicle Security System With Remote Start Table Of Content: Before You Begin Page 2 Wire Harness Quick View Pages 3 & 4 Mounting Of The Major Components Page 5 6 Pin
More informationElectro-Mechanical Swing Operator. Table of Contents
*640072* 640072 Electro-Mechanical Swing Operator Models 8230 & 8240 Installation Instructions Table of Contents General...1 Replacement Parts & System Components...1 1 Pre-Installation Site & Product
More information