1 Drive Technology \ Drive Automation \ System Integration \ Services Data sheet MOVIAXIS MultiAxis Servo Inverter Information regarding UL Edition 0/0 057 / EN

2 SEWEURODRIVE Driving the world

3 Contents Contents Information regarding UL.... Field Wiring Power Terminals.... Short Circuit Current Rating.... Branch Circuit Protection Overload Protection Ambient Temperature... 6 Wiring diagrams Connection of supply module, capacitor / buffer module, axis module, brake and V switchedmode power supply module Connecting braking resistors Connecting of regenerative power module... 6 Information regarding UL Information regarding UL

4 Information regarding UL Field Wiring Power Terminals Information regarding UL. Field Wiring Power Terminals Use 60 / 75 C copper wire only. Tighten terminals to inlbs (Nm) as follows Tightening torque Power supply module Mains connection X Braking resistor terminals Size in.lb ( Nm) in.lb ( Nm) Size in.lb (.0.0 Nm) in.lb (.0.0 Nm) Size in.lb ( Nm) in.lb (.0.0 Nm) Regenerative power module Mains connection X Emergency braking resistor terminals One size in.lb ( Nm) in.lb (.0.0 Nm) Regenerative power module Mains connection X EcoLine Filter in.lb ( 5 Nm) connection X Size in.lb ( Nm) Size in.lb (..5 Nm) Size in.lb (.5.7 Nm) Size in.lb (.0.0 Nm) Size in.lb (.0.0 Nm) Size in.lb ( Nm) DC link discharge module Braking resistor connection X5 All sizes in.lb (.0.0 Nm) Models DClink bars All Models in.lb (.0.0 Nm). Short Circuit Current Rating Suitable for use on a circuit capable of delivering not more than 00,000 rms symmetrical amperes when protected by fuses and circuit breakers as described in the tables below. 65,000 rms symmetrical amperes when protected by ABB and Rockwell Type E Combination lers as described in the tables below. Max. voltage is limited to 500 V. Information regarding UL Information regarding UL

5 Information regarding UL Branch Circuit Protection. Branch Circuit Protection Model MXP8XA00X X (Size ) MXP8XA05X Y (Size ) MXP8XA05X 0 (Size ) MXP8XA050XX (Size ) MXP8XA075XX (Size ) Integral solid state short circuit protection does not provide branch circuit protection. Branch circuit protection must be provided in accordance with the National Electrical Code and any additional local codes. SCCR: 00 ka/ 500 V when protected by: Non Semiconductor Fuses (currents are maximum values) SCCR: 00 ka/ 500 V when protected by: InverseTime Circuit Breaker SCCR: 65 ka/ 80 V when protected by: ) SCCR: 65 ka/ 60 V when protected by: Type E Combination Controller 0 A / 600 V 5 A max / 500 V Min ABB, Model MS0 Rated 80 V, 0 HP 0 A / 600 V ABB, Model MS500E Rated 80 V, 0 HP 80 A / 600 V 75 A max / 500 V Min ABB, Model MS9575E Rated 80 V, 60 HP 80 A / 600 V 75 A max / 500 V Min ABB, Model MS9575E Rated 80 V, 60 HP 5 A / 600 V 75 A max / 500 V Min Rockwell Automation Model 0M D8EC0, Rated 60 V, 5 HP Rockwell Automation Model 0MF8EC5, Rated 60 V, 0 HP ) Drives employing Type E Combination Controller model MS0, must be installed with Current Limiter Series S80W SCLxxxSR manufactured by ABB, otherwise SCCR rated 0kA/ 80Vrms. Model MXR80A075XX (50 kw) MXR80A075XX (75 kw) SCCR: 00 ka/ 500 V when protected by: Non Semiconductor Fuses (currents are maximum values) SCCR: 00 ka/ 500 V when protected by: InverseTime Circuit Breaker SCCR: 65 ka/ 80 V when protected by: SCCR: 65 ka/ 60 V when protected by: Type E Combination Controller 80 A / 600 V 75 A max / 500 V Min ABB, Model MS9575E Rated 80 V, 60 HP 5 A / 600 V 75 A max / 500 V Min MXR8A050XX 00 A / 600 V 75 A max / 500 V Min ABB, Model MS9590E Rated 80 V, 75 HP MXR8A075XX 50 A / 600 V 75 A max / 500 V Min If you use cable cross sections that are dimensioned for a smaller current than the rated current of the unit, make sure that the fuse is dimensioned for the used cable cross section. For information on selecting cable cross sections, refer to the project planning manual. Comply with the countryspecific installation regulations in addition to the above notes. The plugin connections of the V supply are limited to 0 A. Option cards that are supplied via the 0 V and V terminals at the front must be protected individually or in groups by A melting fuses according to UL 8.. Overload Protection The units are provided with load and speedsensitive overload protection and thermal memory retention upon shutdown or power loss. The trip current is adjusted to 50 % of the rated motor current. Information regarding UL Information regarding UL 5

6 Information regarding UL Ambient Temperature.5 Ambient Temperature The units are suitable for an ambient temperature of 5 C. NOTES UL certification does not apply to operation in voltage supply systems without earthed star point (IT systems). 6 Information regarding UL Information regarding UL

7 Wiring diagrams Connection of supply module, capacitor / buffer module, axis module, brake Wiring diagrams. Connection of supply module, capacitor / buffer module, axis module, brake and V switchedmode power supply module.. Wiring of power terminals MXP80.. Size and L L L K L L L Line filter L L L X L L L Cable length < 600 mm ) ) ) ) ) ) Capacitor module Supply module R R U V switchedmode power supply unit X X For connection of BW see chapter "Connection of braking resistor" ** ) = DC link bus bar = (grounding point of housing) = Power shield clamp * When F6 (trip contact at overload relay) triggers, K must be opened and DI00 "Output stage enable" must receive a "0" signal. F6 is a signal contact, which means the resistor circuit must not be interrupted. ** Make sure to provide separate isolation for the brake lines when ling the brakes with V. We recommend using SEW hybrid cables that offer complete shielding with shielding supports as well as separate shielding for the brake line. *** Install the connection cables between the brake rectifier and the brake separately from other power cables when installing the brake rectifier in the cabinet. Joint installation is only permitted with shielded power cables. Information regarding UL Information regarding UL 7

8 Wiring diagrams Connection of supply module, capacitor / buffer module, axis module, brake.. Wiring of power terminals MXP80.. Size L L L K L L L Line filter L L L Cable length < 600 mm X L L L ) ) ) ) ) ) Capacitor module Supply module R R X U X V Switchedmode power supply unit For connection of BW see chapter "Connection of braking resistor" ** ) = DC link bar = (housing grounding point) = Power shield clamp Footnotes: (page 7) 8 Information regarding UL Information regarding UL

9 Wiring diagrams Connection of supply module, capacitor / buffer module, axis module, brake.. Wiring the MXP8.. power connections with integrated braking resistor L L L K X L L L Line filter L L L Cable length < 600 mm L L L Supply module Ri R R Ri U X ** X = (Housing grounding point) = Power shield clamp Footnotes: (page 7) Information regarding UL Information regarding UL 9

10 Wiring diagrams Connection of supply module, capacitor / buffer module, axis module, brake.. Wiring the MXP8.. power connections with external braking resistor L L L K X L L L Line filter L L L Cable length < 600 mm L L L Supply module Ri R R Ri U X Connection of BW see chaoter Connection of braking resistor ** X = (Housing grounding point) = Power shield clamp Footnotes: (page 7) 0 Information regarding UL Information regarding UL

11 Wiring diagrams Connecting braking resistors. Connecting braking resistors Supply module X R R Supply module X R R BW...P F affects K RB RB BW...T T T F6 affects K Supply module X R R Supply module X R R F6 affects K F6 affects K Ω BW... BW BW...P BW...T BW..., BW...0 If the signal contact F6 trips, K must open. When F6 (trip contact at overload relay or temperature switch) triggers, K must open and "Output stage enable" must receive a "0" signal. F6 is a signal contact, which means the resistor circuit must not be interrupted. When the internal temperature switch trips, K must open. When F6 (trip contact at overload relay or temperature switch) triggers, K must open and "Output stage enable" must receive a "0" signal. F6 is a signal contact, which means the resistor circuit must not be interrupted. When the external bimetallic relay (F6) trips, K must open. When F6 (trip contact at overload relay or temperature switch) triggers, K must open and "Output stage enable" must receive a "0" signal. F6 is a signal contact, which means the resistor circuit must not be interrupted. Braking resistor type BW.. BW...0 BW...T BW...P Overload protection External bimetallic relay F6 External bimetallic relay F6 Internal temperature switch or External bimetallic relay F6 Internal bimetallic relay F6 Information regarding UL Information regarding UL

12 Wiring diagrams. BMK brake with terminal box U ** *** X 5a a a K U AC 5 BMK TS BS BMK brake with SB plug connector U ** *** X K 5 BMK TS BS U AC BMK brake with SBB plug connector U ** *** X D B C K 5 BMK TS BS UAC Footnotes: (page 7) Information regarding UL Information regarding UL

13 Wiring diagrams BME brake with terminal box U ** *** X U AC 5a a a F/5 TS BS K DB00 K DGND 5 BME Directly led motor brake U ** X Footnotes: (page 7) Information regarding UL Information regarding UL

14 Wiring diagrams BP brake BMV with terminal box U ** *** X 5a a K DC V 5 BMV BP brake BMV with SB plug connector U ** *** X D C K DC V 5 BMV BP brake BMV with SBB plug connector 650 U ** *** X K DC V 5 BMV Footnotes: (page 7) Information regarding UL Information regarding UL

15 Wiring diagrams BY brake BMV with terminal box U ** *** X 5a a a K DC V 5 BMV TS BS BY brake BMV with SB plug connector U ** *** X D B C K DC V 5 BMV TS BS BY brake BMV with SBB plug connector U ** *** X K 5 BMV TS BS DC V Footnotes: (page 7) BST brake For information about BST brake, refer to the "BST SafetyRelated Module" operating instructions. Information regarding UL Information regarding UL 5

16 Wiring diagrams Connecting of regenerative power module. Connecting of regenerative power module.. Wiring of the power connections without NFH EcoLine filter L L L N DC V 5 6 Cable length 5 m A A K ** K F6 * NOT AUS *** U V W L L L X8 Line filter L L L OFF Cable length.5 m / AWG U Choke U X Cable length.5 m ON K L L L W V U X8 Sa Sb X9 Regenerative power module R R U X X = (grounding point of housing) = Power shield clamp * When F6 (trip contact at overload relay) triggers, K must be opened and "Output stage enable" must receive a "0" signal. F6 is a signal contact, which means the resistor circuit must not be interrupted. ** Emergency stop release delay only in line with applicable system and countryspecific safety regulations and customer specifications. 6 Information regarding UL Information regarding UL

17 Wiring diagrams Connecting of regenerative power module.. Wiring of the power connections with NFH EcoLine filter L L L N DC V 5 A A K F6 * 6 L L L NFH K EMERG. STOP** Cable length 5 m Cable length.5 m / AWG U V W L L L L L L X8 Line filter L L L U Choke U X OFF ON K Cable length m Cable length.5 m L L L W V U X8 Sa Sb X9 Regen. supply module R R U X X = (housing grounding point) = Power shield clamp Footnotes: (page 6) Information regarding UL Information regarding UL 7

18

19

20 SEWEURODRIVE Driving the world SEWEURODRIVE Driving the world SEWEURODRIVE GmbH & Co KG P.O. Box BRUCHSAL GERMANY Phone Fax sew@seweurodrive.com

Operating Instructions

Operating Instructions Drive Technology \ Drive Automation \ System Integration \ Services Operating Instructions MOVIAXIS MultiAxis Servo Inverter Information regarding UL Edition 0/0 685 / EN SEWEURODRIVE Driving the world

More information

Data sheet. MOVIDRIVE MDX60B/61B/62B, MOVIDRIVE MDR60A/61A, MOVIDRIVE compact, MOVIDRIVE A Information regarding UL * _0119*

Data sheet. MOVIDRIVE MDX60B/61B/62B, MOVIDRIVE MDR60A/61A, MOVIDRIVE compact, MOVIDRIVE A Information regarding UL * _0119* Drive Technology \ Drive Automation \ System Integration \ Services *25950274_0119* Data sheet MOVIDRIVE MDX60B/61B/62B, MOVIDRIVE MDR60A/61A, MOVIDRIVE compact, MOVIDRIVE A Information regarding UL Edition

More information

Data Sheet. MOVIDRIVE MDX60B/61B/62B, MOVIDRIVE MDR60A/61B MOVIDRIVE compact, MOVIDRIVE A Information regarding UL

Data Sheet. MOVIDRIVE MDX60B/61B/62B, MOVIDRIVE MDR60A/61B MOVIDRIVE compact, MOVIDRIVE A Information regarding UL Drive Technologie \ Drive Automation \ System Integration \ Services Data Sheet MOVIDRIVE MDX60B/6B/62B, MOVIDRIVE MDR60A/6B MOVIDRIVE compact, MOVIDRIVE A Information regarding UL Ausgabe 03/203 20644

More information

Data sheet. MOVITRAC 07B, MOVITRAC 07A Information regarding UL * _1216*

Data sheet. MOVITRAC 07B, MOVITRAC 07A Information regarding UL * _1216* Antriebstechnik \ Antriebsautomatisierung \ Systemintegration \ Services *23056916_1216* Data sheet MOVITRAC 07B, MOVITRAC 07A Information regarding UL Ausgabe 12/2016 23056916/DE SEW-EURODRIVE Driving

More information

* _0817* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. MOVIMOT MM..D with AC Motors DT/DV

* _0817* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. MOVIMOT MM..D with AC Motors DT/DV Drive Technology \ Drive Automation \ System Integration \ Services *23582456_0817* Revision MOVIMOT MM..D with AC Motors DT/DV Edition 08/2017 23582456/EN SEW-EURODRIVE Driving the world Amendments/revisions

More information

Revision. Mechatronic Drive System MOVIGEAR DBC-B, DAC-B, DSC-B, SNI-B, * _0315*

Revision. Mechatronic Drive System MOVIGEAR DBC-B, DAC-B, DSC-B, SNI-B, * _0315* Drive Technology \ Drive Automation \ System Integration \ Services *21931585_0315* Revision Mechatronic Drive System MOVIGEAR DBC-B, DAC-B, DSC-B, SNI-B, Edition 03/2015 21931585/EN SEW-EURODRIVE Driving

More information

moog MSD Servo Drive UL-Certification MSD Servo Drive product range

moog MSD Servo Drive UL-Certification MSD Servo Drive product range MSD Servo Drive UL-Certification MSD Servo Drive product range 2 UL-Certification Id No : CC36842-001, Rev. 1.0 Date: 05/2017 We reserve the right to make technical changes. The content of our documentation

More information

Synergy EN product information

Synergy EN product information Synergy EN60947-4-2 product information Rated operational voltages U e 200Vac to 480Vac Rated operational currents I e See Rating Table Rating index See Sizing Guide Rated frequency/frequencies 50-60Hz

More information

Thermal overload relay TF65 and TF96

Thermal overload relay TF65 and TF96 Data sheet Thermal overload relay TF65 and TF96 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against overload and

More information

Brake Chopper BC BC 4.1. Instruction and Operation Manual

Brake Chopper BC BC 4.1. Instruction and Operation Manual Brake Chopper BC 2.1 - BC 4.1 Instruction and Operation Manual Caution: There is always a risk involved in the handling of electrical machinery! Therefore mounting and maintenance should only be done by

More information

Electronic overload relays EF205 and EF370

Electronic overload relays EF205 and EF370 Data sheet Electronic overload relays EF205 and EF370 Electronic overload relays offer reliable protection in case of overload and phase-failure. They are the alternative to thermal overload relays. Motor

More information

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130 Operating Manual (Edition 04/2004) sinamics Braking Module / Braking Resistor SINAMICS G130 04/04 Contents Contents 1 Safety Information 1-1 2 General 2-1 3 Mechanical Installation 3-1 4 Connection 4-1

More information

8 BK brakes. 8.1 Description of BK brakes (CMP40 to CMP63) Description of BK brakes (CMP40 to CMP63)

8 BK brakes. 8.1 Description of BK brakes (CMP40 to CMP63) Description of BK brakes (CMP40 to CMP63) 8 BK brakes Description of BK brakes (CMP0 to CMP6) 8 BK brakes 8. Description of BK brakes (CMP0 to CMP6) The mechanical brake is a holding brake implemented as a permanent magnet brake. The standard

More information

For regenerative operation, the MOVIPRO is connected to an external braking resistor.

For regenerative operation, the MOVIPRO is connected to an external braking resistor. External braking resistors for MOVIPRO External braking resistors for MOVIPRO.1 External braking resistors for MOVIPRO For regenerative operation, the MOVIPRO is connected to an external braking resistor.

More information

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF140DU and TF140DU-V1000 Data sheet Thermal overload relay TF140DU and TF140DU-V1000 Thermal overload relays are economic electromechanical protection devices for the main circuit. They are used mainly to protect motors against

More information

Electronic overload relay EF65, EF96 and EF146

Electronic overload relay EF65, EF96 and EF146 Data sheet Electronic overload relay EF65, EF96 and EF146 Electronic overload relays are the alternative to the thermal overload relays. An electronic overload relay offers reliable and fast protection

More information

Technical Information

Technical Information -100 Controller IEC Performance Data (CSA C22.2, UL 508 No. 14 in connection with a short-circuit protection device Catalog No. -100... 25A 40A 63A 90A Maximum Short-Circuit Current 480V [ka] 65 65 42

More information

Braking resistor. Braking resistor types for Infranor drives.

Braking resistor. Braking resistor types for Infranor drives. Braking resistor Braking resistor types for Infranor drives www.infranor.com 1 WARNING! This is a general manual describing various braking resistor types for servo drives having output capability suitable

More information

Question Number: 1. (a)

Question Number: 1. (a) Session: Summer 2008 Page: 1of 8 Question Number: 1 (a) A single winding machine cannot generate starting torque. During starting the switch connects the starting winding via the capacitor. The capacitor

More information

Kinetix 5700 Capacitor Modules

Kinetix 5700 Capacitor Modules Installation Instructions Kinetix 5700 s Catalog Numbers 98-CAP-40, 98-CAP-DCBUS-IO Topic Page About the s Before You Begin Install the s Connector Data 6 Wiring Requirements 8 Additional Resources Summary

More information

1.1 Caution Statements

1.1 Caution Statements USER MANUAL 1.1 Caution Statements Caution Statements cannot cover every potential cause of equipment damage but can highlight common causes of damage. It is the installer's responsibility to read and

More information

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x. Types MS116, MS132, MS5x, MS9x are electromechanical devices for motor and circuit protection. These devices offer local motor disconnect means, manual ON/OFF control, and protection against short circuit,

More information

Revision MOVITRAC LTE-B * _1114*

Revision MOVITRAC LTE-B * _1114* Drive Technology \ Drive Automation \ System Integration \ Services *13599_1114* Revision SEW-EURODRIVE GmbH & Co KG P.O. Box 303 7664 Bruchsal/Germany Phone +49 751 75-0 Fax +49 751-1970 sew@sew-eurodrive.com

More information

Miniature Circuit Breakers

Miniature Circuit Breakers S00 Series Miniature S00 Series Miniature Circuit Breakers Description The S00 Series miniature circuit breaker offers a compact solution for protection requirements. The S00 devices are UL tested limiting

More information

Index. Cable Brakemotor cable for decentralized MOVI SWITCH Catalog AC Motors DR , DT56, DR /EN 10/14

Index. Cable Brakemotor cable for decentralized MOVI SWITCH Catalog AC Motors DR , DT56, DR /EN 10/14 Index A AC motors Mounting position designations... 89 Additional documentation... 12 Add-on encoder cables... 579, 585 Anti-condensation heating... 500 B Backstop... 471 BE brake technical data... 375

More information

Fuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4

Fuses for Semiconductor Protection European Standard Sizes 000 and 00. Protection of Power Semiconductors according to IEC and -4 URB Fuses for Semiconductor Protection European Standard Sizes 000 and 00 Class: ar Voltage ratings: AC 660 V AC 1000 V Current ratings: 16 A to 400 A Approvals: Standards: DIN 43653 IEC 60269-1 and -4

More information

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931 Data Bulletin 0931DB0101 July 2001 Cedar Rapids, IA, USA Ground-Censor Ground-Fault Protection System Type GC Class 931 09313063 GT Sensor Shunt Trip of Circuit Interrupter Window Area for Conductors GC

More information

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Coordinate starter needs for mechanical equipment prior to 50% CD and confirm again for 100% CD submittal. B. Coordinate temperature controls requirements

More information

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4 CHAPTER ELECTRICAL 2 INSTALLATION Contents of this Chapter... 2.1 Warnings & Agency Approvals..................2 2 2.1.1 Isolation..............................................2 2 2.1.2 Electrical Power

More information

Drive Technology \ Drive Automation \ System Integration \ Services MOVITRAC B. Revision. Edition 07/ / EN

Drive Technology \ Drive Automation \ System Integration \ Services MOVITRAC B. Revision. Edition 07/ / EN Drive Technology \ Drive Automation \ System Integration \ Services MOVITRAC B Edition 07/2008 16658019 / EN Revision 1 Notes 1 Notes NOTES This supplementary information does not replace the detailed

More information

Manual. Conversion Aid MOVIDRIVE MDR60A Regenerative Power Supply Unit Series from DCV185 to DCV200

Manual. Conversion Aid MOVIDRIVE MDR60A Regenerative Power Supply Unit Series from DCV185 to DCV200 Drive Technology \ Drive Automation \ System Integration \ Services Manual Conversion Aid MOVIDRIVE MDR60A1320-503-00 Regenerative Power Supply Unit Series from DCV185 to DCV200 Edition 06/2010 16994426

More information

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You

Circuit Breakers. Excerpt from Master Catalogue. Circuit Breakers. Specifically For You Circuit Breakers Specifically For You Excerpt from Master Catalogue Circuit Breakers DIN rail mount, thermal/magnetic circuit breakers. Their compact dimensions, ease of mounting and excellent performance

More information

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web:  - MAKING MODERN LIVING POSSIBLE Quick Setup VLT FCM 300 Series Factory setting Motors type B14 & B34 mounting Reset (pushbutton) Start Jog Speed reference Fig. 1 - Reset to be closed short time for resetting

More information

BT300 Variable Frequency Drive Bypass

BT300 Variable Frequency Drive Bypass Document No. DPD01375 BT300 Variable Frequency Drive Bypass Product Description The Siemens BT300 Bypasses are companion packages for the family of BT300 HVAC Variable Speed Drives. Product Numbers BTC

More information

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24

More information

ABB industrial drives ACS800, drive modules. 2 to Vac 5 to Vac

ABB industrial drives ACS800, drive modules. 2 to Vac 5 to Vac ABB industrial drives ACS800, drive modules Technical catalog 0.75 to 250 HP @ 240 Vac 2 to 2800 HP @ 480 Vac 5 to 2400 HP @ 600 Vac Contents ABB industrial drives 1 2 3 4 Product series Drive Modules

More information

General Purpose US Fuses

General Purpose US Fuses SMARTSPOT with Maximum circuit protection Amp-trap 2000 SmartSpot AJT fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product line the AJT fuse provides

More information

Series L9 UL-489 Miniature Circuit Breakers

Series L9 UL-489 Miniature Circuit Breakers Series UL-489 iniature Breakers Industrial Breakers for Branch up to 40 Amps Sprecher+Schuh includes a line of circuit breakers approved for branch circuit applications in the United States and Canada

More information

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U

Three-phase 200 V series: FRN0025 to 0060C2S-2U Three-phase 400 V series: FRN0013 to 0030C2S-4U Instruction Manual Supplement for FRN-C2S-2U/4U (7.5 to 20 HP) Compact Inverter 200 V series: FRN0025 to 0060C2S-2U series: FRN0013 to 0030C2S-4U Thank you for purchasing our FRENIC-Mini series of inverters.

More information

Essential equipment for all your requirements

Essential equipment for all your requirements NEW CTX CONTACTORS Essential equipment for all your requirements 9 A TO 310 A THREE-POLE INDUSTRIAL CONTACTORS CTX three-pole industrial contactors, a sense of family The new range of CTX contactors provides

More information

SUPPLEMENT MANUAL IM250R03. AQUAVAR CPC SUPPLEMENT A - Variable Speed Drive SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167)

SUPPLEMENT MANUAL IM250R03. AQUAVAR CPC SUPPLEMENT A - Variable Speed Drive SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167) SUPPLEMENT MANUAL IM250R03 AQUAVAR CPC SUPPLEMENT A - Variable Speed Drive SUPPLEMENT TO THE INSTALLATION AND OPERATION MANUAL (IM167) TABLE OF CONTENTS SAFETY Use of Warnings and Notes...3 INSTALLATION

More information

Braking Unit, Braking Resistor Unit

Braking Unit, Braking Resistor Unit YASKAWA AC Drive 1000-Series Option Braking Unit, Braking Resistor Unit Installation Manual Type: CDBR- LKEB- D To properly use the product, read this manual thoroughly and retain for easy reference, inspection,

More information

SMT-BM 20 A BMM 05 F BMM 05 AF

SMT-BM 20 A BMM 05 F BMM 05 AF gb SMT-BM 20 A BMM 05 F BMM 05 AF SINGLE-AXIS RACKS 1 2 SINGLE-AXIS RACKS This is a general manual describing a series of racks receiving servo amplifiers having output capability suitable for driving

More information

Protection Equipment. 5/2 Introduction

Protection Equipment. 5/2 Introduction Protection Equipment /2 Introduction SIRIUS 3RV2 Motor Starter Protectors/ Circuit Breakers up to 40 A /6 General data /12 For motor protection /14 For motor protection with overload relay function /1

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed

More information

NR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA

NR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA R Relays C US LISTED EU Germany Ukrain Russia South Africa USA NR Thermal Overload Relay. General. Certificates: CE, VDE, Ukrain, PCT, RCC, UL;. Electric ratings: AC 50/0Hz, 90V, 0.A~30A;.3 Tripping class:

More information

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B

SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B Solid State Relays SOLITRON MIDI - With Integrated Heatsink Types RJ1A, RJ1B AC semiconductor contactor Zero switching (RJ1A) or instant-on switching (RJ1B) Direct copper bonding (DCB) technology LED-indication

More information

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description UL 489 Series UL 489 Series Description The Series miniature circuit breaker offers a compact solution for protection requirements. The U AND UP devices are UL 489 tested limiting and DIN rail mounted.

More information

Description CMP servomotors are delivered with 2-pole resolvers as standard. Further information on other resolvers is available on request.

Description CMP servomotors are delivered with 2-pole resolvers as standard. Further information on other resolvers is available on request. Motor types Standard type encoders 11 11 Motor types 11.1 Standard type encoders 11.1.1 Resolver Type designation /RH1M Description CMP servomotors are delivered with 2-pole resolvers as standard. Further

More information

UMBW-UL489 and UL1077 Listed

UMBW-UL489 and UL1077 Listed -UL489 and UL77 Listed Introducing the New WEG Series Thermal-Magnetic Miniature Breakers. This new offering includes both UL489 and UL77 approvals to provide a solution for circuit & equipment protection

More information

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI . Technical Data and Specifications Ratings Frames EG, JG and LG EG JG LG Maximum rated current (amperes) 15, 160 1 50 400, 630 Breaker type 3 B B E S S H H C E S H C U X E S H C U X of poles 1, 3, 4,

More information

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E Issued to: ABB FRANCE ACTIVITE PROTECTION ET CONTROL 10 RUE AMPERE 69685 CHASSIEU CEDEX FRANCE This is to certify that representative samples of MOTOR CONTROLLERS, MAGNETIC See Addendum Pages Have been

More information

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00, Low-Voltage Controls and Distribution > Industrial Controls > Protection Equipment > Circuit Breakers/Motor Starter Protectors > Motor Starter Protectors SIRIUS RV up to 00 A RV0-0DA5 CIRCUIT-BREAKER,

More information

COMBIVERT F5 ELEVATOR DRIVE

COMBIVERT F5 ELEVATOR DRIVE COMBIVERT F5 ELEVATOR DRIVE Version 1.72 00.F5.LUB-K172 This instruction manual describes the COMBIVERT F5 ELEVATOR DRIVE. Before working with the unit the user must become familiar with it. This especially

More information

Solid State Relays, 3-phase

Solid State Relays, 3-phase PMA Prozeß- und Maschinen-Automation GmbH Solid State Relays, 3-phase Zero-Point switching, heatsink integrated Main Characteristics: Three-phase controlled Zero switching LED display Various connection

More information

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA: Supersedes: 160.55-PW4 (1199) FORM 160.55-PW4 (600) PRODUCT DRAWING YORK INTERNATIONAL CORPORATION P.O. Box 1592, YORK, PA 17405 CONTRACTOR ORDER NO. YORK CONTRACT NO. YORK ORDER NO. WIRING DIAGRAM FIELD

More information

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany File E47705 Project 97ME18400 August 21, 1997 REPORT on MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany Copyright 1997 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above

More information

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame

Cutler-Hammer Molded Case Circuit Breakers Amperes. January 2001 Vol. 1, Ref. No. [0477] G-Frame Cutler-Hammer January 200 Vol., Ref. No. [077] s Molded Case s 5-00 Amperes 2- 2-2 Product Line Overview January 200 Vol., Ref. No. [068] 2 Product Line Description Cutler-Hammer Molded Case s are designed

More information

TMC 91H is now TMC 60 C Series

TMC 91H is now TMC 60 C Series TMC 91H is now TMC 60 C Series The new Thermal Magnetic Circuit Breaker is once again available and better than ever! The new version is not only UL recognized with the same electrical performance as the

More information

Cabinet-built single drives, ACS880-07

Cabinet-built single drives, ACS880-07 Cabinet-built single drives, ACS880-07 Our cabinet-built single drives are built to order, meeting customer needs despite any technical challenges. Designed on ABB's common drives architecture, this compact

More information

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised: File E47705 Vol. 7 Sec. 9 Page 1 Issued: 1997-08-29 and Report Revised: 2005-06-30 DESCRIPTION PRODUCT COVERED: USL, CNL - Type Nos. 3RV1021, 3RV1121, 3RV1321 or 3RV1421, followed by combination of 0,

More information

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION.   quality IN MOTION IRT quality IN MOTION www.irtsa.com 4000 AT-S/M/L Technical Manual IRT quality IN MOTION E2 0 8 4 1 5 September 2013-Rev. 5 UL Requirements Drives Series 2000 / 4000 AT 1. Field wiring terminal to use

More information

ZE motor-protective relay Overload monitoring of EEx e motors

ZE motor-protective relay Overload monitoring of EEx e motors Building Automation Industrial Automation Systems Hardware and Engineering ZE motor-protective relay Overload monitoring of EEx e motors 0/0 AWB300-5GB A Think future. Switch to green. All brand and product

More information

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer DATASHEET - ZB65-65 Delivery program Overload relay, 50-65A, 1N/O+1N/C Part no. ZB65-65 Catalog No. 278460 Eaton Catalog No. XTOB065DC1 EL-Nummer 0004131855 (Norway) Product range Overload relay ZB up

More information

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA Table of Contents TPS NQ & AQ Series Overview 2 Switchboard Technical Data 3-5 Panelboard Technical Data 5-11 1 Tier Power

More information

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB Motors Automation Energy Transmission & Distribution Coatings UMBW UL489 and UL1077 Thermal-Magnetic MCB UL489 AND UL1077 Circuit Protection Overview: Single pole and multi-pole thermal-magnetic minature

More information

Application guide. Tmax Link OEM UL 891 Switchboard Program

Application guide. Tmax Link OEM UL 891 Switchboard Program Application guide Tmax Link OEM UL 891 Switchboard Program 04 Tmax Link Overview 04 Standards 04 UL File Extension Process Overview 05 Electrical Data 05 Technical Data 05 Ambient Conditions 08 Circuit

More information

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60

Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60 Solid State Relays Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60 Zero switching (RM1A) or instant-on switching (RM1B) AC Solid State Relay Direct copper bonding

More information

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation M T E C o r p o r a t i o n dv/dt Filter Series A 440-600 VAC USER MANUAL PART NO. INSTR - 019 REL. 041119 2004 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation dv/dt Filter is designed

More information

Power systems Protection course

Power systems Protection course Al-Balqa Applied University Power systems Protection course Department of Electrical Energy Engineering Dr.Audih 1 Part 3 Protective Devices Fuses & Circuit Breakers 2 Introduction: Fuse Is advice used

More information

Single Cable Motion Solution Kinetix 5500 Servo Drive and VP Low Inertia Motor

Single Cable Motion Solution Kinetix 5500 Servo Drive and VP Low Inertia Motor Single Cable Motion Solution Kinetix 5500 Servo Drive and VP Low Inertia Motor 2 Kinetix 5500 Servo Drive and VPL motor The Kinetix 5500 and VP Low Inertia Motor are designed to connect and operate with

More information

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units

Table Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units -22 2 Amperes January 1 Vol. 1, Ref. No. [0488] Table -. FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. Cont. Ampere Rating @ 40 C 600V AC Maximum, 0V DC 277V AC Maximum,

More information

FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS

FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS Supersedes: 160.75-PW2 (508) Form 160.75-PW2 (311) FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS WIRING DIAGRAM CONTRACTOR ORDER NO. YORK CONTRACT NO.

More information

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3 Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

SD Series Non-Fused Load Switches

SD Series Non-Fused Load Switches SD Series Non-Fused Load Switches The SD1 and SD2 series of non-fused load switches are listed as Manual Motor Controllers and are designed for use in local motor isolation. The SD series of modular load

More information

Braking Unit, Braking Resistor Unit

Braking Unit, Braking Resistor Unit YASKAWA AC Drive Option Braking Unit, Braking Resistor Unit Installation Manual CDBR- D LKEB- Type: CDBR- LKEB- D To properly use the product, read this manual thoroughly and retain for easy reference,

More information

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A) Controls THERMAL OVERLOAD RELAYS RW..D (up to 0A) 0800 7 9 Thermal Overload Relays RW..D (up to 0A) THERMAL OVERLOAD RELAYS RW..D (up to 0A) Summary Introduction RW7-D Thermal Overload Relay from 0.8 up

More information

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters. Lecture 6 Contactors and Motor Starters ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters Text Book: Chapter 6, Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill, 2015. Paul I-Hai

More information

Series KTU7 UL489 Molded Case Circuit Breakers

Series KTU7 UL489 Molded Case Circuit Breakers Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current

More information

Motor Protection. Presented By. Scott Peele PE

Motor Protection. Presented By. Scott Peele PE Motor Protection Presented By Scott Peele PE Motor Protection Overload on the motor load Fuses Heater Magnetic relay Short Circuit on motor circuit Fuses Breakers Single Phasing Overload Protection NEC

More information

WARREN COUNTY, N.Y. M/E REFERENCE

WARREN COUNTY, N.Y. M/E REFERENCE SECTION 262000 - ELECTRIC DISTRIBUTION PART 1 - GENERAL 1.1 DESCRIPTION A. Provide a complete secondary distribution system as indicated on the Contract Documents and as specified herein. 1.2 QUALITY ASSURANCE

More information

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits Fuses for Semiconductor Protection - European Standard Class: ar Voltage ratings: 660V AC to 1000V AC Current ratings: 16 A to 400 A Standards: UL 248-13 IEC 60269-1 & 4 DIN VDE 0636-40 DIN 43653 Approvals:

More information

COMBIVERT F5 ELEVATOR DRIVE

COMBIVERT F5 ELEVATOR DRIVE COMBIVERT F5 ELEVATOR DRIVE Version 1.72 00.F5.LUB-K172 REV 1D -09/2015 This instruction manual describes the COMBIVERT F5 ELEVATOR DRIVE. Before working with the unit the user must become familiar with

More information

POWER FACTOR CORRECTION MOTOR LOAD (ML) FIXED CAPACITOR

POWER FACTOR CORRECTION MOTOR LOAD (ML) FIXED CAPACITOR User s Manual for The POWER FACTOR CORRECTION MOTOR LOAD (ML) FIXED CAPACITOR 301 Gaddis Boulevard Dayton, Ohio 45403 U.S. Toll Free 866-261-1191 (937) 253-1191 Fax: (937) 253-1723 Web site: www.stacoenergy.com

More information

ABB industrial drives ACS800, single drives ACS800, regenerative AC drives ACS800, ultra low harmonic drives

ABB industrial drives ACS800, single drives ACS800, regenerative AC drives ACS800, ultra low harmonic drives ABB industrial drives ACS800, single drives ACS800, regenerative AC drives ACS800, ultra low harmonic drives Technical catalog 0.75 to 75 HP @ 240 Vac 2 to 2250 HP @ 480 Vac 5 to 3000 HP @ 600 Vac BUSINESS

More information

Manual motor starter MS132

Manual motor starter MS132 Data sheet Manual motor starter MS132 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less

More information

ABB industrial drives ACS800, single drives ACS800, regenerative AC drives ACS800, ultra low harmonic drives

ABB industrial drives ACS800, single drives ACS800, regenerative AC drives ACS800, ultra low harmonic drives ABB industrial drives ACS800, single drives ACS800, regenerative AC drives ACS800, ultra low harmonic drives Technical catalog 0.75 to 75 HP @ 240 Vac 2 to 2250 HP @ 480 Vac 5 to 3000 HP @ 600 Vac BUSINESS

More information

ABB machinery drives. Application guide Common DC system for ACS380 drives

ABB machinery drives. Application guide Common DC system for ACS380 drives ABB machinery drives Application guide Common DC system for ACS380 drives List of related manuals Drive manuals and guides ACS380 hardware manual ACS380 firmware manual ACS380 quick installation and start-up

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

Control Circuit Protection

Control Circuit Protection Contents 5SJ4 Branch Circuit Protectors 5SY4 Supplementary Protectors 5SY6 Supplementary Protectors 16/19 5SJ4 Page Selection and ordering data 1-pole up to 63A 16/4 1-pole, 2-pole, 16/5 3-pole, 240VAC

More information

Drive Technology \ Drive Automation \ System Integration \ Services. Revision MOVIFIT FC

Drive Technology \ Drive Automation \ System Integration \ Services. Revision MOVIFIT FC Drive Technology \ Drive Automation \ System Integration \ Services Revision MOVIFIT FC Edition 09/2010 17022819 / EN SEW-EURODRIVE Driving the world Type Designation of MOVIFIT FC Sample EBOX nameplate

More information

Manual motor starters Overview and benefits

Manual motor starters Overview and benefits Manual motor starters Overview and benefits ABB offers a complete standard motor-protection concept for the world market IEC motor branch protection UL type E/F Motor applications with fuseless protection

More information

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 060628 2006 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter

More information

Cutler-Hammer. January 2001

Cutler-Hammer. January 2001 Cutler-Hammer Vol. -2 Product Line Overview Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case s are designed to provide circuit protection for low voltage distribution systems.

More information

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X Manual motor protectors Type MS116 Type MS32 Type MS4X Type MS49X Manual motor protectors MS116 MS32 MS4X MS49X Description Type MS116 Suitable for use with 3-phase motors up to 10 HP @ 480V UL ed and

More information

J1000 D E F I 1000 J1000 J1000 J1000 J1000

J1000 D E F I 1000 J1000 J1000 J1000 J1000 Compact Inverter SERIES J1000 GB D E F I 1000 J1000 J1000 J1000 J1000 The J-Type YASKAWA Inverter Drive Technology Contents Page 2 Experience & Innovation A leader in Inverter Drives technology Page 3

More information

DIN EN UL 508 / CSA 3RF A A 0 2

DIN EN UL 508 / CSA 3RF A A 0 2 PMA Prozeß- und Maschinen-Automation GmbH Solid State Relays Zero-Point Switching, heatsink integrated Main Characteristics: Zero switching LED display Various connection technologies Plug-in control terminal

More information

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting. DATASHEET - ZB12-2,4 Delivery program Overload relay, 1.6-2.4 A, 1N/O+1N/C Part no. ZB12-2,4 Catalog No. 278437 Eaton Catalog No. XTOB2P4BC1 EL-Nummer 0004131832 (Norway) Product range Overload relay ZB

More information

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD. DATASHEET - DILMC9-10(24VDC) Technical data General Contactor, 3p+1N/O, 4kW/400V/AC3 Part no. DILMC9-10(24VDC) Catalog No. 277468 Eaton Catalog No. XTCEC009B10TD EL-Nummer 4110305 (Norway) Standards IEC/EN

More information