1 o.fdm005c BRUSHLESS BLOWER 60DCF475 60DCF477 60DCF478 nstruction Manual Minebea Co., Ltd. Special Device Business Unit 585 Katase, Fujisawa, Kanagawa Contact Us Special Device Commercial Product Sales Management Mita, Minatoku, Tokyo TEL (0) FX (0)

2 60DCF475 BLOWER :6075 DRVER :MDS0L000 60DCF477 BROWER :6076 DRVER :MDS0L000 60DCF478 BROWER :6077 DRVER :MDS0L000 o.fdm005c BRUSHLESS BLOWER nstruction Manual 60DCF475 (00W),60DCF477 (800W),60DCF478(600W) <Safety Precautions> Thank you for adopting a Minebea product. For proper use, please carefully read this nstruction Manual and other supporting documents before usage (installation, operation, maintenance, inspection). Do not use until all technical/safety information and reminders are fully understood. Keep the nstruction Manual in an accessible place for ready reference and also make sure that it is delivered to end customers. General notes <Configuration> The photograph shows a 60DCF475. This product was developed for use in industrial equipment. Do not use for equipment in areas which require a high degree of reliability and safety such as aerospace equipment, trunkline communication equipment, nuclear control equipment, life support machines, automobiles, traffic signals, medical devices, and so forth. Minebea will take no responsibility for failures which arise from false or inappropriate use of the product, such as not complying with product usage conditions and precautions depicted in the specifications (drawings) and instruction manual. Please request a reference drawing or delivery specifications to confirm. Due to performance upgrades and production reasons, the product specifications, exterior, and configurations described in these specifications are subject to change without prior notice. Do not use it in outdoor. n this <Safety Precaution>, the safety precaution levels are classified as "WRG" and "CUTO." WRG ndicates a potential situation that could result in death or serious injury to user if device is operated improperly. CUTO ndicates a potential situation that could result in injury to user or physical damage if device is operated improperly.. Precautions against electrical shock W R G Do not modify or disassemble this product. Doing so may cause electrical shock. Before conducting wiring operations and inspection, confirm that no voltage is present at the driver terminal using a tester or the like 0 minutes after the power supply is turned OFF. Conduct a Cclass(earth resistance 0Ω or less) or higher earth connection for the Blower and Driver. Wiring work and inspection should be performed by a professional engineer (a Second Class Electrician or higher is recommended). n order to prevent electric shock and injury, conduct wiring after the main body is set in place. n order to prevent electric shock, avoid touching the Blower and Driver with wet hands. n order to prevent electric shock, do not damage, forcibly pull, place heavy objects on, or pinch the Blower cable. n order to prevent electric shock, do not connect or disconnect the blower connector while C power is being supplied (during Operation and Standby).

3 o.fdm005c. Precautions against fire C U T O n case of Blower or Driver malfunction, cut off the power supply. Continuous flow of a large amount of current may cause fire. Do not connect the control /O connector to the C power supply. Doing so may cause fire. Do not block the vent hole of the Driver. Doing so may cause fire. Do not use with the air inlet or outlet of the Blower completely blocked. Doing so may cause fire.. Precautions against failure C U T O Do not apply voltage other than the rated voltage specified for each terminal. Doing so may result in blowout or damage. Do not mix up the terminal connections. Doing so may result in explosion or damage. Do not reverse the polarity (+, ). Doing so may result in explosion or damage. Do not touch the Blower and Driver while power is turned on or for a while after power is turned off as they may be hot. Doing so may result in burns. Do not put tools, fingers, or other objects near the Blower inlet/outlet and the Driver vent hole. Doing so may result in explosion or damage. 4. Miscellaneous Precautions Please pay adequate attention to the following precautions. mproper handling may cause unexpected accident, electrical shock, or injury. C U T O () bout transportation and mounting Transport the product using a correct method that corresponds to the product weight. Failure to do so may cause injuries. Do not stack higher than recommended. nstall Blower using the main frame mounting feet. Do not install directly on air inlet or outlet. nstall Driver using the main frame mounting feet. Do not mount in any direction other than that indicated in drawings. nstallation should be made on a structure that can withstand the product weight and vibration. Do not operate with a damaged Blower or Driver installed. Do not hold cover or lead wire during active operation. Doing so may result in damage. Do not step on or place objects on the product. Direction of the Blower duct (exhaustion and suction) must conform to the specified requirements. f the Blower is installed without ducting on the inlet and outlet, directly used in ambient air, an appropriate protection frame or screen must be applied to the inlet and outlet to ensure safety. Prevent conductive objects such as screws and metal pieces and flammable objects such as oil as well as other foreign objects that can disturb the rotation of the Blower from entering the inside of the Blower and Driver. s the Blower and Driver are precision instruments, do not drop or apply unreasonable force. Please use under the environmental conditions given below. Usage under other environmental conditions may lead to malfunction. mbient Temperature: 0 to +50 (no frost) mbient Humidity: 90 % RH or less (no frost) Storage Temperature: 0 to +65 Other conditions: To be used indoors. o corrosive gases, flammable gases, oil mist, powder, or dust. ltitude above sea level: 000 m or lower Vibration: 5.9m/s or less(jsc09 compliant) Do not use in a closed area. Use in a wellventilated area.

4 o.fdm005c C U T O () bout wiring Connect load (CL) and neutral (C) of the C power supply input correctly. Do not apply C power to the FG terminal. n order to protect the Blower, connect a Current Overload Protection device (a breaker or an electromagnetic switch) of 5 to the device. Do not conduct an insulation resistance test or a dielectric strength voltage test. () bout trial operations Consider how to prevent malfunction of the Blower and Driver from affecting other devices. (4) bout usage Do not apply C power while a control input signal is being provided. Doing so will cause the Blower to restart suddenly. Do not start/stop Blower using the braker or the electromagnetic switch of the C power supply. lways precede start/stop with a control input signal. Reduce the effects of electromagnetic disturbance by placing a noise filter near the Blower. (5) Measures in case of abnormality Consider how to prevent a machine/device from being in a hazardous situation even in the event of Blower malfunction. (6) bout Maintenance and nspection Perform the contents below at least once a year. Check for abnormalities (such as abnormal noise) while the device is in a running state. f dust is attached to the vent hole, air inlet, or Driver cover, remove it. (7) bout storage The storage period should not exceed 6 months. (8) bout disposal Please treat as general industrial waste. (9) Operating Precautions f an unusual noise or smell is noticed, immediately terminate the C power supply and control input signal, stop usage, and then contact the distributor. 4

5 o.fdm005c.part names <BLOWER> <DRVER> UP D M O R U E C T T O G The photograph shows a 60DCF475 Blower Vent hole Mounting feet Lead wire(motor) 4 Lead wire(sensor) 5 ir nlet cover 6 ir Outlet 7 Housing 8 ir nlet The photograph shows a 60DCF475 Driver Vent hole Mounting feet Cooling fan 4 Driver BOX 5 Cover 6 Sensor Connector 7 Motor Connector 8 Control input/output Connector 9 C nput Terminal block.connection Diagram Drive Connector Connector Connector Open collector DC 0~0V Blower Terminal block C 入力 60DCF475,477 :C80~64V 60DCF478 only :C 90~64V 5

6 input / output teminal o.fdm005c Connection Terminal o. Terminal name Contents Specification Remarks S_CTR Speed control input Between S_CTR terminal and The Blower output can be CTR_GD terminal adjusted by adjusting the input voltage (+ side) nput voltage:dc 0 ~ 0 V (ote ) nput current: m or less Connector (SGL) (ote ) 4 CTR_GD FOLT FOLT_GD Speed control input (GD side) Error output in abnormal circumstances Between FOLT terminal and FOLT_GD terminal Open collector output (ote 4) The signal can be output by connecting the pullup resistor on the outside. Pull up voltage:5 V or less Error : Low Output Error output in abnormal Sink current:0 m or less Rotation : Pulse Output circumstances (GD side) Terminal block FG Frame GD t connects it with the earth. (CPUT) S_CL C single phase input (nonearth side) C 80~64V (note ) S_C C single phase input C 90~64V(60DCF478 only) (earth side) Connector CT_ Sensor connector input for (SESOR) blower Connector CT_ Motor connector input for (MOTOR) blower ote : The connection must use the connector (The maker: JST and model number: XHP4). ote : Driver connection to input terminal block should be firmly fixed using a crimptype terminal with an insulating cover. (Recommendation: R.5 4, JSC805 compliance) and electric wire equivalent to or larger than.5 mm. ote : Please input the DC voltage that meets the input voltage specification between the terminal S_CTR and the terminal CTR_GD. ote 4: FOLT terminal is open collector output of a photo coupler, so when using as signal output, please make the pull up outside in resistance which meets the specification outside. f terminal block is placed near the Blower, make sure vibration / air stream does not cause mechanical fatigue of wire. Fixed attachment to a nylon clamp and/or duct is recommended. Make sure connector is pushed all the way down..rotation Speed Modulator The Blower output can be adjusted by adjusting the input voltage between the control /O connector terminal S_CTR and the CTR_GD terminal. nput voltage: 0 V DC to 0 V DC, nput current: m or less Please input the DC voltage that meets the input voltage specification between the terminal S_CTR and the terminal CTR_GD. 4.Guaranteed term t will assume the responsibility of the repair or the exchange free of charge about the accident that occurs because of imperfect of a design or a defective material or construction by the time it reaches either condition from an initial delivery to within year or 5000 hours in the total operation time. However, will not do this guarantee in the following cases. ()When it is admitted that the breakdown was caused by user's fault. () when it was used under the prescribed conditions for use and the condition beyond the environment. ()When it is caused because of manufacturing other than Blois. (4) when it depends on user's remodeling. (5) when fire and a natural disaster depend on irresistible force We don't shoulder this responsibility about the secondary claim. 6

7 o.fdm005c 5.Specification 60DCF475 o. tem Specification Remarks Rated air flow.9 m /min any more (0 atmosphere) t air pressure 0 kpa C 40V +0% 5% Current t stop :C 0.6 or less ncluding blower and drivers t rating:c 8.0 or less at C 40V Supply voltage Single phase 80V~64V C40Vrms (+0%,5%) 50/60Hz 60DCF477 o. tem Specification Remarks Rated air flow 4 m /min any more (0 atmosphere) Blower exhaust hole open C 40V +0% 5% Current t stop :C 0.6 or less ncluding blower and drivers t rating:c 8.0 or less at C 40V Supply voltage Single phase 80V~64V C40Vrms (+0%,5%) 50/60Hz 60DCF478 o. 4 tem Specification Remarks ir flow.5 m /min any more Blower exhaust hole open ir pressure 0kPa any more Blower exhaust hole close Current t stop :C 0.6 or less t rating:c 8.0 or less Supply voltage Common specification Single phase C00Vrms (±0%) C40Vrms (+0%,5%) 50/60Hz (0 atmosphere) C 00V ±0% ncluding blower and drivers at C 00V 90V~64V o. tem Specification Remarks Operating temperature 0 ~ +50 Operating condition. range Storage temperature 0 ~ +65 onoperating condition. range Operating humidity 0% ~ 80% range 4 nsulation class class B 5 Mass Blower :.0 kg or less Driver :.5 kg or less 6 Mounting direction Blower :xis horizontal Driver :Vertical 6.Others Blower and driver is away from the closed space, please set up to where the air enters from outside. Use beyond the operating temperature limit causes a breakdown. Please don't carry around with a harness of blower. The lead wires to the C input terminals are short circuit because of the risk of contact with driver box cover, please use ring terminals with insulation. fter wiring, please be sure to use terminal cover attached. Please note that product can be subject to change without notice. 7

8 o.fdm005c 7.Dimensions BLOWER(60DCF475 60DCF477 60DCF478 same size) name plate color 60DCF475:white 60DCF477:red 60DCF478:blue DRVER(MDS0L000) UP Driver mounting direction 8

Filterpack FR-BFP2-(H)0.4K to (H)15K

Filterpack FR-BFP2-(H)0.4K to (H)15K INVERTER INSTRUCTION MANUAL FR-BFP2-(H)0.4K to (H)15K 1. Product Checking... 1 2. Applicable Inverter... 1 3. Installation... 2 3.1 Inverter Installation (installation of the )...2 4. Wiring... 4 5. Main

More information

I. Safety precautions

I. Safety precautions . Safety precautions The items described in these instructions and on the inverter itself are very important so that you can use the inverter safely, prevent injury to yourself and other people around

More information

BEFORE USING THE PRODUCT

BEFORE USING THE PRODUCT HL-17015-5 BEFORE USING THE PRODUCT Thank you for purchasing an Oriental Motor product. Please read this BEFORE USING THE PRODUCT and the separate manual entitled OPERATING MANUAL thoroughly to ensure

More information

This section is specifically about safety matters

This section is specifically about safety matters 6 4 ) 1 6 4 1 -, 1 8-4 6-4 1 6 4 7 + 6 1 ) 7 ) - -, - - + 6. 4 ) 6 J E? A Thank you for choosing this Mitsubishi transistorized Inverter option. This instruction manual gives handling information and precautions

More information

VF-S11 RS485 built-in board option RS4003Z Instruction Manual

VF-S11 RS485 built-in board option RS4003Z Instruction Manual VF-S11 RS485 built-in board option RS4003Z Instruction Manual NOTICE 1. Make sure that this instruction manual is delivered to the end user of RS485 built-in option board. 2. Read this manual before installing

More information

MITSUBISHI LARGE CAPACITY INVERTER MELTRAC-REC(MT-REC) -INSTRUCTION MANUAL- 12 Pulse Bridge Converter

MITSUBISHI LARGE CAPACITY INVERTER MELTRAC-REC(MT-REC) -INSTRUCTION MANUAL- 12 Pulse Bridge Converter A MITSUBISHI LARGE CAPACITY INVERTER 12 Pulse Bridge Converter MELTRAC-REC(MT-REC) -INSTRUCTION MANUAL- NOTICE : READ ENTIRE MANUAL PRIOP TO CONNECTING AND OPERATING EQUIPMENT IB-T7237B Thank you for choosing

More information

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2 Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.

More information

Spec.No. CBF2525-VBVB-01E-1. Orion Model CBF2525-VBVB-01. Date Aug APPD CKD DWN. Kuroiwa Yamada Takei Takahashi ORION MACHINERY CO., LTD.

Spec.No. CBF2525-VBVB-01E-1. Orion Model CBF2525-VBVB-01. Date Aug APPD CKD DWN. Kuroiwa Yamada Takei Takahashi ORION MACHINERY CO., LTD. Spec.No. CBF2525-VBVB-01E-1 Orion Trade Name DRY PUMP Orion Model CBF2525-VBVB-01 Date Aug.30.2011 APPD CKD DWN Y. F. N. Y. Kuroiwa Yamada Takei Takahashi ORION MACHINERY CO., LTD. Spec.No. CBF2525-VBVB-01E-1

More information

Extended Panel Operation Manual RKP001Z-0

Extended Panel Operation Manual RKP001Z-0 Extended Panel Operation Manual RKP001Z-0 Table of Contents 1. NAMES AND FUNCTIONS OF MAIN PARTS...3 2. CONNECTION AND START-UP...4 3. DIMENSIONS...5 4. PROTECTION FUNCTION...6 5. SPECIFICATIONS...6 6.

More information

NIDEC COPAL ELECTRONICS CORP. 1 / 7. Model No. Issuing Date

NIDEC COPAL ELECTRONICS CORP. 1 / 7. Model No. Issuing Date NIDEC COPAL ELECTRONICS CORP. / 7 Specifications Model No. Issuing Date TF037C-200-P Aug., 207. Scope This specification applies to Blower Kit:TF037C-200-P (hereinafter referred to as "the PRODUCT"), a

More information

Brushless DC Motor Unit. Brushless DC Motor (24 V DC Input) 50 W Model 24DCM W Model 24DCM-372 MDS-01AL

Brushless DC Motor Unit. Brushless DC Motor (24 V DC Input) 50 W Model 24DCM W Model 24DCM-372 MDS-01AL Brushless DC Motor Unit Brushless DC Motor (24 V DC Input) 50 W Model 24DCM-371 100 W Model 24DCM-372 Driver MDS-01AL002-01 User s Guide Thank you for purchasing the Minebea 24DCM brushless DC motor unit.

More information

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4 Braking Resistor Units 3G3IV-PCDBR2 B/4 B Braking Units Thank you for choosing an OMRON Braking Resistor Unit and Braking Unit. Proper use and handling

More information

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY EB RELAYS (AEB) (1A type) FEATURES Compact and high capacity using double contacts in series and permanent magnet installed. (1,A/3 times)

More information

OPERATING MANUAL. High-efficiency AR Series. Stepping motor and driver package. Introduction. Applicable motor. Before use

OPERATING MANUAL. High-efficiency AR Series. Stepping motor and driver package. Introduction. Applicable motor. Before use HM-08 OPERATING MANUAL Stepping motor and driver package High-efficiency AR Series DC power input Built-in Controller Type (RS-8 communication function) Driver Introduction Before use Only qualified personnel

More information

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER THT-500-A/R No.THT51E1 2017.12 Thank you for purchasing our THT-500-A/R, Temperature and Humidity Transmitter (mounted within control panel). This

More information

DC-DC STEP DOWN CONVERTER CV 24/12V - 15 A Pro

DC-DC STEP DOWN CONVERTER CV 24/12V - 15 A Pro User s Manual DC-DC STEP DOWN CONVERTER CV 24/12V - 15 A Pro ACMA115 INTRODUCTION Thank you for choosing a PRESIDENT product. You can be sure that the product you have purchased is one of the best that

More information

NIDEC COPAL ELECTRONICS CORP.

NIDEC COPAL ELECTRONICS CORP. 1 / 8 Specifications Model No. TF037F-2000-F Issuing Date Aug.1, 2017 1.Scope This document applies to Blower TF037F-2000-F (hereinafter referred to as "PRODUCT"), a product of NIDEC COPAL ELECTRONICS

More information

EVS RP6020. Instruction Manual

EVS RP6020. Instruction Manual Instruction Manual TDK Lambda BEFORE USING THE PRODUCT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product.

More information

ZWS-BAF Series. Instruction Manual. TDK-Lambda. ZWS-BAF Series Instruction Manual A H

ZWS-BAF Series. Instruction Manual. TDK-Lambda. ZWS-BAF Series Instruction Manual A H BEFORE USING THE POWER SUPPLY UNIT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product. Incorrect usage could

More information

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake

Instruction Manual. Table of Contents. Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake ZJ-267A Powder Clutch, Brake MODEL ZKB-AN,BN Powder Clutch ZKB-YN,XN Powder Brake Instruction Manual Table of Contents Cautions on Safety - - - - - - - - - - - - - - - - - 1 1. Cautions before use - -

More information

Submersible Pump Instructions. Safety Instructions

Submersible Pump Instructions. Safety Instructions Submersible Pump Instructions Safety Instructions Before operating of this pump, read this manual and follow all safety rules and operating instructions. Before operating of this pump, read this manual

More information

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual. Walrus America Inc. ISO 9001 Certified TPH Series MULTISTGE CENTRIFUGL PUMP Instruction Manual ISO 9001 Certified Walrus merica Inc 234867 EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. ddress: No. 83-14, Dapiantou, Sanjhih

More information

Lumitester PD-20 Control Kit

Lumitester PD-20 Control Kit 日本語による取扱説明は 17 ページからとなります Lumitester PD-20 Control Kit Operation manual Thank you for purchasing the Lumitester PD-20 Control Kit. To use this kit safely and correctly, read this operation manual carefully

More information

VECTOR INVERTER -INSTRUCTION MANUAL- ADDITIONAL OPEN COLLECTOR OUTPUT / PLG PULSE DIVISION OUTPUT FR-V5AY

VECTOR INVERTER -INSTRUCTION MANUAL- ADDITIONAL OPEN COLLECTOR OUTPUT / PLG PULSE DIVISION OUTPUT FR-V5AY VECTOR INVERTER -INSTRUCTION MANUAL- ADDITIONAL OPEN COLLECTOR OUTPUT / PLG PULSE DIVISION OUTPUT FR-V5AY Thank you for choosing the Mitsubishi vector inverter option unit. This instruction manual gives

More information

SAFETY PRECAUTIONS (Always read these precautions prior to use.)

SAFETY PRECAUTIONS (Always read these precautions prior to use.) Terminal Block Converter Module for Programmable Controller Analog Module Model FALTB40DAG, FATB20TD, FALTB40ADGN, FALTB40TDG, FATB20TC, FALTB40ADDG, FALTB40RD3G Terminal Block Converter Module for Programmable

More information

DC I/O Conversion Module FA1-TESV32XY FA1-TESV38COM User's Manual

DC I/O Conversion Module FA1-TESV32XY FA1-TESV38COM User's Manual DC I/O Conversion Module FA1-TESV32XY FA1-TESV38COM User's Manual Thank you for purchasing the FA Goods product. Before using the product, please read this User s Manual and the relevant manuals carefully

More information

NIDEC COPAL ELECTRONICS CORP.

NIDEC COPAL ELECTRONICS CORP. NIDEC COPA EECTRONICS CORP. 1 / 5 Specifications Model No. TF037C-2100-F Issuing Date Aug.1, 2017 1. Scope This specification applies to Blower TF037C-2100-F (hereinafter referred to as "the PRODUCT"),

More information

INSTRUCTION MANUAL MANOSTAR TRANSMITTER EMT1. RoHS READ THE INSTRUCTION MANUAL BEFORE USING. No. TR-EMT1-E08

INSTRUCTION MANUAL MANOSTAR TRANSMITTER EMT1. RoHS READ THE INSTRUCTION MANUAL BEFORE USING. No. TR-EMT1-E08 RoHS READ THE INSTRUCTION MANUAL BEFORE USING INSTRUCTION MANUAL MANOSTAR TRANSMITTER No. TR--E08 1-2-,Nishi-shiriike-cho,Nagata-ku,Kobe,Hyogo 65-001 JAPAN TEL. +81(78)-61-6000 FAX. +81(78)-61-6020 INTRODUCTION

More information

SHOCK RELAY R INSTRUCTION MANUAL WARNING

SHOCK RELAY R INSTRUCTION MANUAL WARNING EHFSB006000A0 SHOCK RELAY R TSBSB Series INSTRUCTION MANUAL! WARNING Make sure you read this instruction manual thoroughly before installing, wiring, operating and inspecting this SHOCK RELAY Please make

More information

ZWS-BP Series. Instruction Manual. TDK-Lambda. ZWS-BP Series. Instruction Manual A C

ZWS-BP Series. Instruction Manual. TDK-Lambda. ZWS-BP Series. Instruction Manual A C BEFORE USING THE POWER SUPPLY UNIT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product. Incorrect usage could

More information

Read and understand this manual for safely usage.

Read and understand this manual for safely usage. TS02-0183 INSTRUCTION MANUAL FOR GUARD TYPE LEVEL SENSOR MODEL:FC Read and understand this manual for safely usage. This manual describes the product of standard specification. Read the other manual for

More information

No.LV31JE To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

No.LV31JE To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. INSTRUCTION MANUAL LEVEL SWITCH LV-300 No.LV31JE2 2008.05 To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual. Safety Precautions (Be sure to

More information

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference. Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories. Be sure to thoroughly read and understand the SAFETY PRES given in this section before using the equipment in order to operate the equipment correctly. The precautionary measures described in this section

More information

AZ Series Motor OPERATING MANUAL. Introduction. Safety precautions. CE Marking

AZ Series Motor OPERATING MANUAL. Introduction. Safety precautions. CE Marking HM-6244-3 OPERATING MANUAL Closed Loop Stepping and Driver Package AZ Series Introduction Before use Only qualified personnel should work with the product. Use the product correctly after thoroughly reading

More information

PANcharge1k Battery Charger User's Manual

PANcharge1k Battery Charger User's Manual PANcharge1k Battery Charger User's Manual Ver.1.00E Table of Contents 1. Important Safety Instructions... 3 1-1 General Safety Precautions... 3 1-2 Battery Precautions... 3 1-3 Electromagnetic Disturbance...

More information

MCF3 25CT Inrush-withstand

MCF3 25CT Inrush-withstand RoHS Pb Dimensions and construction: (mm) Case: End-cap substrate metal: End-cap primary plating: End-cap surface plating: Adhesive: Marking: Ceramic Copper t=0.25 mm Nickel plated, 0.5 μm or more Tin

More information

Lead-free glass Nickel plated brass Ceramic 100 ma 15 A. Tube: End-cap: Core: Solder: 200 A. Marking: 100 ma 8 A Over 8 A 20 A. Rated breaking current

Lead-free glass Nickel plated brass Ceramic 100 ma 15 A. Tube: End-cap: Core: Solder: 200 A. Marking: 100 ma 8 A Over 8 A 20 A. Rated breaking current * RoHS Dimensions and construction: (mm) Tube: End-cap: Core: Solder: Marking: Lead-free glass Nickel plated brass Ceramic 100 ma 15 A 20 A 100 ma 8 A Over 8 A 20 A Sn-1.5Cu Pb87.5-Sn10.0-Ag2.5* Pb90-Cu*

More information

DIGITAL CLAMP TESTER MODEL HCL-5000D

DIGITAL CLAMP TESTER MODEL HCL-5000D DIGITAL CLAMP TESTER MODEL HCL-5000D INSTRUCTION MANUAL Thank you very much for selecting our digital clamp tester model HCL-5000D for AC line current in Hi-voltage circuit. This model is complex instrument

More information

POWER REGULATOR LD -40PSU

POWER REGULATOR LD -40PSU JZ99D4121A AMPIFIRE AMPIFIRE TYPE D-4PSU ZJ-46A ISTRUCTI MAUA Manual number JZ99D4121 Sub number A Date of preparation ov. 2 Thoroughly read this instruction manual, and then use the unit correctly. Especially,

More information

Instruction Manual for Safety and Comfort

Instruction Manual for Safety and Comfort GMH500160110 *GMH500160110* Instruction Manual for Safety and Comfort All of the Safety Instructions contained in this Manual must be read carefully and must be fully understood before you attempt to use

More information

High Vacuum Diaphragm-Type Dry Vacuum Pump

High Vacuum Diaphragm-Type Dry Vacuum Pump No 腄 26300-2-02-3 High Vacuum Diaphragm-Type Dry Vacuum Pump DTC-120 DTC-120A, 120B, 120C (According to CE) Request to Users Please read this manual thoroughly to ensure safe and effective use of the equipment.

More information

Selection Guide SANKEN ELECTRIC CO.,LTD

Selection Guide SANKEN ELECTRIC CO.,LTD SANKEN ELECTRIC CO.,LTD Selection Guide 3-phase DC Brushless Motor Driver IC (35 V to 60 V) DC Brush Motor Driver IC (44 V) Stepper Motor Driver IC - Bipolar (40 V to 60 V) - Unipolar (100 V) The all contents

More information

SPECIFICATIONS. Soundproof Diesel Engine-Driven DC Welder MODEL DAW-300SSEK. [50Hz,220V] HEAD OFFICE

SPECIFICATIONS. Soundproof Diesel Engine-Driven DC Welder MODEL DAW-300SSEK. [50Hz,220V] HEAD OFFICE SPEC.No. D48343 02814 DATE F e b. 1 9, 2 0 0 8 SPECIFICATIONS Soundproof Diesel Engine-Driven DC Welder MODEL DAW-300SSEK [50Hz,220V] HEAD OFFICE 2-8-5 Nihonbashi-horidomecho, Chuo-ku, Tokyo, 103-8566

More information

Power Inverter 400 MW Owner s Manual

Power Inverter 400 MW Owner s Manual Power Inverter 400 MW 1204 Owner s Manual For safe and optimum performance, the Power Inverter must be used properly. Carefully read and follow all instructions and guidelines in this manual and give special

More information

Transmitter CSA-591 Instruction Manual

Transmitter CSA-591 Instruction Manual Transmitter CSA-591 Instruction Manual EN294-1141-F FOREWORD Thank you very much for your purchasing our Transmitter CSA 591. This manual explains installation procedures and connecting method and also

More information

Installation and Service Manual for RV33, RV332, RV75, RV752, RV100, RV1002

Installation and Service Manual for RV33, RV332, RV75, RV752, RV100, RV1002 Rotary Vane Compressors RV Series Installation and Service Manual for RV33, RV332, RV75, RV752, RV100, RV1002 Thank you for purchasing the Stratus RV series rotary vane compressor. This instruction manual

More information

The Power of Reliability INSTRUCTION MANUAL

The Power of Reliability INSTRUCTION MANUAL The Power of Reliability INSTRUCTION MANUAL SAFETY & WARNINGS Read this manual carefully and understand all Warnings and Cautions before connections are made to the Inverter. If unsure about any aspects

More information

Lead-free glass Nickel plated brass 62 ma 1.25 A Over 1.25 A 3 A Epoxy resin 62 ma less than 1 A. Tube: End-cap: Solder: Adhesive: Marking: 1 A 3 A

Lead-free glass Nickel plated brass 62 ma 1.25 A Over 1.25 A 3 A Epoxy resin 62 ma less than 1 A. Tube: End-cap: Solder: Adhesive: Marking: 1 A 3 A RoHS Pb Dimensions and construction: (mm) Tube: End-cap: Solder: Adhesive: Marking: Lead-free glass Nickel plated brass 62 ma 1.25 A Over 1.25 A 3 A Epoxy resin 62 ma less than 1 A 1 A 3 A Sn-0.7Cu Sn-3.0Ag-0.5Cu

More information

MEMS Air Velocity Sensor D6F-W. Application Examples. Ordering Information

MEMS Air Velocity Sensor D6F-W. Application Examples. Ordering Information MEMS Air Velocity Sensor Compact, intelligent sensors featuring MEMS precision technology for repeatable airflow detection. Precision uni-directional air velocity detection. Integral passive Dust Segregation

More information

Pure sine wave charger inverter Product Manual

Pure sine wave charger inverter Product Manual Pure sine wave charger inverter Product Manual The inverter installer must be professional, for the high pressure in the inverter, unprofessional person please do not open it. The inverter should be installed

More information

MCF3 DC86V11CT Inrush-withstand

MCF3 DC86V11CT Inrush-withstand RoHS Pb Dimensions and construction: (mm) Case: Cover: Terminal substrate metal: Terminal primary plating: Terminal surface plating: Adhesive: Marking: Ceramic Ceramic Copper t=0.1 mm Nickel plated copper,

More information

High-frequency AC Method. panasonic-electric-works.net/sunx

High-frequency AC Method. panasonic-electric-works.net/sunx 1091 PHOTO PHOTO Thin Type Ionizer High-frequency AC Method General terms and conditions... F-17 Related Information Glossary of terms... P.1401 guide... P.1075~ General precautions... P.1405 Conforming

More information

HYBRID HYDRAULIC O OIL COOLING EQUIPMENT O-1

HYBRID HYDRAULIC O OIL COOLING EQUIPMENT O-1 HYBRID HYDRAULIC O OIL COOLING EQUIPMENT O-1 List of Hybrid Unit Models Various specifications for each model. DAIKIN s lineup provides a variety of functions and capacities depending on the machine type.

More information

PL Submersible, Semi-Vortex, Water Feature Pump

PL Submersible, Semi-Vortex, Water Feature Pump TM M 2001992 Introduction Submersible, Semi-Vortex, Water Feature Pump This manual provides information and procedures to safely install, operate and maintain this TSURUMI model. For your own safety and

More information

TOWA SEIDEN INDUSTRIAL CO., LTD.

TOWA SEIDEN INDUSTRIAL CO., LTD. INSTRUCTION MANUAL SOUNDING LEVEL METER MODEL: TLX-120AP/200AP Meanings of indications for safety used in this Instruction Manual are as follows. WARNING: Indicates that improper handling assumes the risk

More information

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit SSR with Failure Detection Function Detects failures in SSRs used for heater temperature control and simultaneously outputs alarm signals. This product supports the safe design of heater control systems,

More information

Braking unit Option Instruction Manual PB7-4132K

Braking unit Option Instruction Manual PB7-4132K Braking unit Option Instruction Manual PB7-4132K NOTICE 1. Make sure that this instruction manual is delivered to the end user of Braking unit option. 2. Read this manual before attaching the Braking unit

More information

Read and understand this manual for safely usage.

Read and understand this manual for safely usage. TS02-0180 INSTRUCTION MANUAL FOR AIR BUBBLER SYSTEM LEVEL MEASUREMENT MODEL:LA100 MODEL:LA110 MODEL:LA1000 Read and understand this manual for safely usage. This manual describes the product of standard

More information

TR514H-D DC 5 Phase Micro Stepping Motor Driver User's Manual

TR514H-D DC 5 Phase Micro Stepping Motor Driver User's Manual TR14H-D-TS-V01E TR14H-D DC Phase Micro Stepping Motor Driver User's Manual Selection for 1~20 micro divisions Switch for two kinds of division externally Small volume, Simple controlling Reverse power

More information

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date:

ISP-500B. Oil-free Scroll Vacuum Pump. Instruction Manual. View our inventory. Record of Pump Information. Serial Number: Purchase date: ISP-500B Oil-free Scroll Vacuum Pump Instruction Manual View our inventory Serial Number: Record of Pump Information Purchase date: In Service date: Dealer information: IM-500B 1/3/07 Page 1 of 26 Important

More information

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL AL- Model Number Date Code / Serial Number Date of Purchase LIMITED WARRANTY ALITA warrants to the original retail consumer purchaser ( Customer ) that

More information

User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh)

User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh) User s Manual Lithium-ion Storage Battery Unit (Home-use, 9.89 kwh) EOW-LB100-PNUS2 Thank you for purchasing this product from Tabuchi Electric. Read this User s Manual carefully to ensure safe use of

More information

1/2 HP SUMP PUMP OWNER'S MANUAL

1/2 HP SUMP PUMP OWNER'S MANUAL TM 1/2 HP SUMP PUMP OWNER'S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious

More information

TSURUMI MANUFACTURING CO., LTD.

TSURUMI MANUFACTURING CO., LTD. 17200075/B-10073-5 OM COMPACT SUBMERSIBLE SEMI-VORTEX PUMP OPERATION MANUAL FOR DEWATERING INTRODUCTION Thank you for selecting a Tsurumi Compact Submersible Semi-Vortex pump for your dewatering application.

More information

Installation & Operation Manual

Installation & Operation Manual GFR30 ROTARY TYPE POWDER FILLING & CAPPING MACHINE Installation & Operation Manual 1. Summarize GFR30 rotary type powder filling machine is arranged the container by conveyor belt and send to station for

More information

RP Instruction Manual

RP Instruction Manual Instruction Manual TDK Lambda BEFORE USING THE PRODUCT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product.

More information

BITMAIN. APW PSU Series User Guide

BITMAIN. APW PSU Series User Guide BITMAIN APW5-12- 2600 PSU Series User Guide 1 Content 1. Overview... 3 2. Features... 3 3. Specifications... 4 4. Order Information & Wire Type... 6 5. Trouble Shooting & FAQ... 7 6. Precautions for Use...

More information

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24

20 amps 220 amps, 60 Hz VDC VAC G3PA-420B-VD-2 DC amps 440 amps, 60 Hz G3PA-450B-VD-2 DC12-24 Solid State Relays (SSRs) G3PA/G3PB Long Service Life for Circuits that Cycle Frequently D D D D D Built-in heat sink increases life and reliability Voltage turn-on at zero crossing reduces initial inrush

More information

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007) Installation, Operation and Maintenance Manual (from February 2007) Publication 2698C (GB) 0207 1A 3319 8035B Donaldson reserve the right to alter design without notice. Freedom from patent restrictions

More information

Tube: End-cap: Core: Solder: Lead-free glass Nickel plated brass Ceramic Sn-1.5Cu. Pb87.5-Sn10-Ag2.5* ma less than 1 A.

Tube: End-cap: Core: Solder: Lead-free glass Nickel plated brass Ceramic Sn-1.5Cu. Pb87.5-Sn10-Ag2.5* ma less than 1 A. * 1 RoHS Dimensions and construction: Tube: End-cap: Core: Solder: Lead-free glass Nickel plated brass Ceramic Sn-1.5Cu (mm) Marking: Pb87.5-Sn10-Ag2.5* 1 100 ma less than 1 A 1 A 15 A SOC [rated current]

More information

troubleshooting Outdoor Unit: KSIE009-H221-O, KSIE012-H220-O, KSIE018-H220-O KSIE024-H220-O, KSIR036-H218, KSIR048-H218

troubleshooting Outdoor Unit: KSIE009-H221-O, KSIE012-H220-O, KSIE018-H220-O KSIE024-H220-O, KSIR036-H218, KSIR048-H218 troubleshooting Table of Contents 1. Troubleshooting Model Numbers: Indoor Unit: KDIR09-H2, KTIR09-H2, KUIR09-H2 KDIR12-H2; KTIR12-H2, KUIR12-H2 KDIR18-H2, KTIR18-H2, KUIR18-H2 KDIR24-H2, KTIR24-H2, KUIR24-H2

More information

EX Series. Electric Actuators for Ball and Butterfly Valves

EX Series. Electric Actuators for Ball and Butterfly Valves EX Series Electric Actuators for Ball and Butterfly Valves Next Generation Electrical Actuator Realization of Upgraded General-Purpose Actuators The modularization and the adoption of common parts have

More information

CONTENTS 0.005 0.004 0.003 0.002 0.001 0 SE15 SE23SC23 SE30SC30 SE45SC45 0 200 400 600 800 1000 Category Option Manufactured by order (Note 8) Item SG series SE series SC series Motor Intermediate

More information

Instruction Manual. DMF-1-Series Coriolis Mass Flow Meter

Instruction Manual. DMF-1-Series Coriolis Mass Flow Meter 1 京制 01050054 号 Instruction Manual DMF-1-Series Coriolis Mass Flow Meter Beijing Sincerity Automatic Equipment Co., LTD Tel: +86(010)52073959/ 52073956 18600270515 2 NOTICE We thank you very much for your

More information

2-Color Display High-Precision Digital Pressure Switch

2-Color Display High-Precision Digital Pressure Switch 2-Color Display High-Precision Digital Pressure Switch Series ZSE3/ISE3 2-color digital display allows you to choose the setting according to your application requirements. 4 different display settings

More information

Air duct switching damper

Air duct switching damper English LOSSNAY HEAT RECOVERY VENTILATOR SYSTEM COMPONENT Air Duct Switching Damper MODEL P-133DUE-E Applicable Model VL-220CZGV-E Air duct switching damper Contents 1. Safety Precautions 2 2. Outside

More information

230VAC Power Inverter 400W Owner s Manual

230VAC Power Inverter 400W Owner s Manual 400W 230VAC Power Inverter 400W Owner s Manual For safe and optimum performance, the Enerdrive epower Inverter must be used properly. Carefully read and follow all instructions and guidelines in this manual

More information

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372

TPH Series. MULTISTAGE CENTRIFUGAL PUMP Instruction Manual WALRUS PUMP CO., LTD. ISO 9001 Certified NSF/ANSI 372 TPH Series MULTISTAGE CENTRIFUGAL PUMP Instruction Manual NSF/ANSI 372 ISO 9001 Certified WALRUS PUMP CO., LTD. EC Declaration of Conformity Manufacturer: Walrus Pump Co., Ltd. Address: No.8314, Dapiantou,

More information

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to PRM-4 Phase Sequence and Motor Rotation Tester Users Manual For detailed specifications and ordering info go to www.testequipmentdepot.com PRM-4 Phase Sequence and Motor Rotation Tester English Users Manual

More information

DC power supply connect to VF-AS1/PS1 Optional initial charger MCR-2550 Instruction manual

DC power supply connect to VF-AS1/PS1 Optional initial charger MCR-2550 Instruction manual DC power supply connect to VF-AS1/PS1 Optional initial charger Instruction manual NOTE 1. Make sure that this instruction manual is delivered to the end user of the optional initial charger. 2. Read this

More information

Differential Pressure Transmitter

Differential Pressure Transmitter Specifications/Instructions Differential Pressure Transmitter General Model PY9000D is a differential pressure transmitter that uses a ceramic cantilever sensor. Deflection of the ceramic cantilever caused

More information

DRB-1 Series Instruction Manual

DRB-1 Series Instruction Manual Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.

More information

Installation manual. Modbus Interface DIII EKMBDXA7V1. Installation manual Modbus Interface DIII. English

Installation manual. Modbus Interface DIII EKMBDXA7V1. Installation manual Modbus Interface DIII. English Modbus Interface DIII EKMBDXA7V1 Modbus Interface DIII English 379 mm 0 C 100 mm 50 mm 50 mm 40 mm 87 mm 300 mm IP X0 50 mm 60 C 365 mm 124 mm Max. 100 mm Min. 1 2 3 1 www.daikineurope.com/support-and-manuals/product-information/

More information

Measurements are expressed in millimeters.

Measurements are expressed in millimeters. T-Rex user manual Measurements are expressed in millimeters. 1 Lamp access 2 Focus adjustment 3 Mounting bracket 4 Swivel locks 5 Clamp hole 6 Air vent 190 285 7 AC input & main fuse 8 Microphone 490 164

More information

Remote Control Engine Starter System Owner s Manual

Remote Control Engine Starter System Owner s Manual Remote Control Engine Starter System Owner s Manual Introduction 1. Introduction 2 2. Features of the System 3 3. Safety Precaution 4 4. Name of each part 6 5. Display 7 6. Operating the Transmitter 8

More information

Battery Unit BHM60PC/BHM100PC Instruction Manual

Battery Unit BHM60PC/BHM100PC Instruction Manual Battery Unit BHM60PC/BHM100PC Instruction Manual For the use of UPS BH60PCW/BH100PCW This manual contains important information regarding the safe use of the BHM60PC/BHM100PC for the Backup Power Supply

More information

Matala. VersiFlow Series. Instruction and Maintenance Manual

Matala. VersiFlow Series. Instruction and Maintenance Manual VersiFlow Series High Flow Multi-Purpose "Versatile " Pump V-3200 1/5HP 150W / Discharge 2 V-3900 1/3HP 250W / Discharge 2 V-4700 1/2HP 400W / Discharge 2 V-5600 1HP 750W / Discharge 2 Instruction and

More information

User Manual. SV-DBH Series. LG Dynamic Braking Units. LG Industrial Systems

User Manual. SV-DBH Series. LG Dynamic Braking Units. LG Industrial Systems User Manual L Dynamic Braking Units SV-H Series Read this manual carefully before installing, wiring, operating, servicing or inspecting the unit. Keep this manual within easy reach for quick reference.

More information

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual Version 1.1 Version 2 Nature Power Inverters True Sinewave Inverter Modified Sinewave Inverter Owner s Manual!!!!!!!!!!! 38304 38204 For safe and optimum performance, the Power Inverter must be used properly.

More information

FR-CV POWER REGENERATION COMMON CONVERTER MODEL

FR-CV POWER REGENERATION COMMON CONVERTER MODEL OER REGEERATIO COMMO COVERTER MOEL FR-CV Mitsubishi Electric Corporation agoya orks is a factory certified for ISO400 (standards for environmental management systems) and ISO900(standards for quality assurance

More information

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING dv Sentry TM 208V 600V INSTALLATION GUIDE FORM: DVS-IG-E REL. January 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION 11/05 Form #273 OPERATING INSTRUCTION MODEL 4105 Disital Earth Resistance Tester 2150 joshua's Path, Suite 302, Hauppauge, NY 11788 Phone : 1-800-645-5398 or 1-639-231-7050 Fax : 1-639-434-3128 E-mail

More information

Lead-free glass Nickel plated brass Ceramic Tin plated copper Sn-1.5Cu Pb87.5-Sn10.0-Ag2.5* SOC NSD9 D32V [rated current]

Lead-free glass Nickel plated brass Ceramic Tin plated copper Sn-1.5Cu Pb87.5-Sn10.0-Ag2.5* SOC NSD9 D32V [rated current] * RoHS Dimensions and construction: (mm) Tube: End-cap: Core: Lead wire: Solder: Marking: Lead-free glass Nickel plated brass Ceramic Tin plated copper Sn-1.5Cu Pb87.5-Sn10.0-Ag2.5* SOC NSD9 D32V [rated

More information

Check-Rod Type Mounting Attachment with Slide Stop Mechanism CCACC010- B (S) Instruction Manual EN E

Check-Rod Type Mounting Attachment with Slide Stop Mechanism CCACC010- B (S) Instruction Manual EN E Check-Rod Type Mounting Attachment with Slide Stop Mechanism CCACC010- B (S) Instruction Manual EN294-1365-E Forward Thank you very much for your purchasing Minebea's Mounting attachment with slide stop

More information

Model Number Structure

Model Number Structure Conductive Level Controller CSM DS_E_1_1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at or using self-holding circuits. Sensitivity adjustment of operating

More information

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3

SOS SERIES SOS1 SOS2. Spares On Site Battery Cabinet Installation Guide rEV3 Atlantic Battery Systems 1065 Market Street Paterson, NJ 07513 Phone: (800) 875-0073 Fax: (973) 523-2344 sales@atbatsys.com www.atbatsys.com SOS1 SOS2 SOS SERIES Spares On Site Battery Cabinet Installation

More information

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories.

cause injury to humans and other physical damage. : Gives information that does not fall in the WARNING or CAUTION categories. Be sure to thoroughly read and understand the SAFETY PRES given in this section before using the equipment in order to operate the equipment correctly. The precautionary measures described in this section

More information

Duplex Booster System Instruction Manual

Duplex Booster System Instruction Manual Duplex Booster System Instruction Manual ISO 9001 Certified Walrus America Inc Congratulations on your purchase of Walrus IC Series Inverter Control System. Please read all instructions carefully before

More information

Installation manual wall-mounted distributor

Installation manual wall-mounted distributor EN Installation manual wall-mounted distributor EN 60003233 Issue 11.2016 2016-14-11 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3 Signal words used 4 2

More information