Testing and Reporting Requirements for Linear Replacement Lamps

Size: px
Start display at page:

Download "Testing and Reporting Requirements for Linear Replacement Lamps"

Transcription

1 Testing and Reprting Requirements fr Linear Replacement Lamps The DLC defines all tube-style LED prducts that use the lamp hlders (i.e. sckets r tmbstnes) in the luminaire t mechanically r electrically cnnect t the fixture husing and electric supply t fall under these testing requirements. Prducts that d nt emply lamp hlders will be classified as Retrfit Kits, regardless f frm factr. Please see the Prduct Eligibility page and Technical Requirements fr mre details n prduct classificatin. The DLC accepts QPL applicatins fr tw-ft, three-ft, fur-ft, eight-ft, and U-Bend Linear Replacement Lamps. The Testing and Reprting Requirements described belw are intended t evaluate the perfrmance f the lamp itself, and its perfrmance in an apprpriate reference fixture, representative f the mst cmmn applicatin fr each flurescent replacement lamp type. General Applicatins Tw-ft, three-ft, and U-bend replacement lamp general applicatins are restricted t LED lamps intended t replace flurescent T8. Eight-ft replacement lamps are restricted t lamps intending t replace T8 flurescent lamps. Fur-ft replacement lamp general applicatins are restricted t LED lamps intended t replace flurescent T8, T5, and T5HO lamps at this time. Prduct specificatin sheets must clearly indicate fr which specific linear replacement lamp type (i.e. T8, T5, r T5HO) the prduct is intended, and list the base type and the nminal length in inches. T8 Tw-Ft Linear Replacement Lamps LED lamps intended t replace T8 flurescent lamps. These LED lamps shall be 24 inches lng and emply a G13 base. Marketing material shall indicate that they are intended t replace T8 flurescent lamps f the same length. Prducts f different lengths and bases are nt eligible under this general applicatin. Prducts intended t perate n magnetic ballasts are nt eligible. Testing and Reprting Requirements fr Linear Replacement Lamps Page 1 f 17

2 T8 Three-Ft Linear Replacement Lamps LED lamps intended t replace T8 flurescent lamps. These LED lamps shall be 36 inches lng and emply a G13 base. Marketing material shall indicate that they are intended t replace T8 flurescent lamps f the same length. Prducts f different lengths and bases are nt eligible under this general applicatin. Prducts intended t perate n magnetic ballasts are nt eligible. T8 Fur-Ft Linear Replacement Lamps LED lamps intended t replace T8 flurescent lamps. These LED lamps shall be 48 inches lng and emply a G13 base. Marketing material shall indicate that they are intended t replace T8 flurescent lamps f the same length. Prducts f different lengths and bases are nt eligible under this general applicatin. Prducts intended t perate n magnetic ballasts are nt eligible. T5 Fur-Ft Linear Replacement Lamps LED lamps intended t replace T5 flurescent lamps (nte, nt T5 High Output r T5HO). These LED lamps shall be 46 inches lng and emply a G5 base. Marketing material shall indicate that they are intended t replace T5 flurescent lamps f the same length. Prducts f different lengths, bases, r marketed as intended t replace ther types f flurescent lamps are nt eligible under this general applicatin. T5HO Fur-Ft Linear Replacement Lamps LED lamps intended t replace T5HO flurescent lamps. These LED lamps shall be 46 inches lng and emply a G5 base. Marketing material shall indicate that they are intended t replace T5HO flurescent lamps f the same length. Prducts f different lengths, bases, r marketed as intended t replace ther types f flurescent lamps are nt be eligible under this general applicatin. T8 Eight-Ft Linear Replacement Lamps LED lamps intended t replace T flurescent lamps. These LED lamps shall be 96 inches lng and emply a FA8 base. Marketing material shall indicate that they are intended t replace T flurescent lamps f the same length. Prducts f different lengths and bases are nt eligible under this general applicatin. Prducts intended t perate n magnetic ballasts are nt eligible. Testing and Reprting Requirements fr Linear Replacement Lamps Page 2 f 17

3 U-Bend Replacement Lamps LED lamps intended t replace T8 flurescent lamps. These LED lamps shall emply a G13 base. Marketing material shall indicate that they are intended t replace T8 flurescent lamps f the same shape. Prducts f different bases are nt eligible. Primary Use Designatins Under the Technical Requirements Table, replacement lamps will fall under ne f the fllwing fur Primary Use Designatins: Replacement Lamps (UL Type A): Tw-ft, three-ft, fur-ft, eight-ft, and U-bend LED "tubes" designed t replace tw-ft, three-ft, fur-ft, eight-ft, and U-bend flurescent lamps, respectively. Prducts in this primary use designatin emply lamp hlders t cnnect t the fixture being retrfitted and are designed t be "plug and play" replacements fr flurescent lamps. That is, prducts in this categry perate utilizing an existing flurescent ballast, and d nt require mechanical r electrical changes t the fixture. Nte that due t testing cnsideratins, at this time nly prducts that perate utilizing specific ballasts types are eligible. Please see Fixture Level Test requirements belw. Replacement lamps designed t perate utilizing magnetic ballasts r ther types f electrnic ballasts nt specified are nt eligible at this time. Internal Driver/Line Vltage Lamp-Style Retrfit Kits (UL Type B): Tw-ft, three-ft, fur-ft, eight-ft, and U-bend LED "tubes" designed t replace tw-ft, three-ft, fur-ft, eight-ft, and U-bend flurescent lamps, respectively. Prducts in this categry emply lamp hlders t cnnect t the fixture being retrfitted, but d nt perate utilizing the existing flurescent ballast. These prducts require rewiring f the existing fixture t bypass the ballast and send line vltage directly t the lamp hlders. External Driver Lamp-Style Retrfit Kits (UL Type C): Tw-ft, three-ft, fur-ft, eight-ft, and U-bend LED "tubes" designed t replace tw-ft, three-ft, fur-ft, eight-ft, and U-bend flurescent lamps, respectively. Prducts in this categry emply lamp hlders t cnnect t the fixture being retrfitted, d nt perate utilizing the existing flurescent ballast, and require rewiring f the existing fixture t replace the Testing and Reprting Requirements fr Linear Replacement Lamps Page 3 f 17

4 ballast with an external driver. The lamp hlders are then wired t receive nly the lw-vltage electricity that is supplied by that external driver. Dual Mde Internal Driver (UL Type A and Type B): Tw-ft, three-ft, fur-ft, eight-ft, and U-bend LED "tubes" designed t replace tw-ft, three-ft, fur-ft, eight-ft, and U-bend flurescent lamps, respectively. Prducts in this categry perate utilizing the existing flurescent ballast and als have the ability t perate utilizing line vltage if the fixture is rewired t bypass the ballast. These prducts cnnect t the fixture using standard pin-base cnnectins t the lamp hlders. Nte that due t testing cnsideratins, at this time nly prducts that perate utilizing specific ballasts types are eligible. Please see testing requirements belw. Replacement lamps designed t perate utilizing magnetic ballasts, r ther types f electrnic ballasts nt specified, are nt eligible at this time. Fr testing purpses, the DLC requires testing f bth the bare lamp and lamps installed in a typical fixture husing. These typical fixture husings are intended t prvide testing results f the mst cmmn applicatins in which these prducts are used, including representative thermal cnditins f the fixtures in which the lamps wuld be installed. In specifying these fixture husings, the DLC des nt endrse r exclude any particular make r mdel frame fr use in energy efficiency prgrams. Supprting Dcumentatin Applicants shall prvide the fllwing supprting dcumentatin in additin t the test data described belw. Installatin Instructins Installatin instructin sheets must be submitted with the applicatin t indicate hw the replacement lamp will be installed in an existing fixture in the field. This must be prvided in additin t all necessary dcumentatin required fr ther prduct categries. Lamps that require specialized cmpnents fr installatin t perfrm t the abve criteria are nt eligible fr qualificatin. Lamps that emply rtatable end-caps are eligible, but must clearly indicate this feature in the prduct spec sheet. Testing and Reprting Requirements fr Linear Replacement Lamps Page 4 f 17

5 Safety Certificatin Dcumentatin DLC has updated the Safety Certificatin Dcumentatin requirements and prcesses. The dcumentatin required fr the lamp under the new plicy must be submitted with the crrespnding applicatin. Please review the updated Safety Certificatin Dcumentatin detailed requirements utlined in the V4.3 Primary Technical Requirements page released with this dcument. Bth plicies will be fficially implemented n March 26 th, Lamp Level Tests All lamps seeking qualificatin by the DLC must test the bare lamp accrding t LM- 79. Table 1: Individual Replacement Lamp Criteria: T8, T5, and T5HO Replacements Individual Lamp Criteria Tw-ft Lamps, T8 replacements Three-ft Lamps, T8 replacements Fur-ft Lamps, T8 replacements Fur-ft Lamps, T5 replacements Fur-ft Lamps, T5HO replacements Eight-ft Lamps, T8 replacements U-bend Lamps, T8 replacements System Efficacy 110 lm/w 110 lm/w 110 lm/w 110 lm/w 110 lm/w 110 lm/w 110 lm/w Initial Light Output Crrelated Clr Temp. (CCT) Clr Rendering Index (CRI) 800 lm 1,200 lm 1,600 lm 1,600 lm 3,200 lm 3,200 lm 1,400 lm 5000K 5000K 5000K 5000K 5000K 5000K 5000K Pwer Factr Ttal Harmnic Distrtin 20% 20% 20% 20% 20% 20% 20% Testing Ntes Fr T8 replacement lamps designed t perate utilizing existing flurescent ballasts, testing must be cnducted using a standard 0.88 ballast factr, electrnic instantstart ballast. Fr T5 and T5HO replacement lamps designed t perate utilizing existing flurescent ballasts, testing must be cnducted using a nrmal 1.0 ballast factr, electrnic prgrammed-start ballast. Specificatin sheets fr the ballasts used during testing must be prvided with the applicatin and the ballast make and Testing and Reprting Requirements fr Linear Replacement Lamps Page 5 f 17

6 mdel number must be nted in the test reprt. Ballasts used in testing must be certified t the applicable safety standards and must cmply with applicable ANSI standards. Fr Type B and Type C prducts (i.e. lamp-style retrfit kits, which cnnect mechanically and/r electrically t the fixture via standard lamp hlders, but which require an electrical mdificatin t the existing fixture), lamp -level testing is als required. If the system is designed t perate multiple lamps utilizing an external driver, the driver shuld be laded as it wuld be in the field, with apprpriate steps taken t calculate the efficacy f the single lamp. Fr example, fr a tw-lamp kit, ne lamp shuld be measured fr light utput, while the system as intended (with tw identical lamps n the driver) shuld be measured fr electrical input. The wattage int the driver can then be divided by tw, and that wattage divided int the lamp lumens t determine system efficacy. Fr questins, please cntact applicatins@designlights.rg. Fixture Level Tests: Tw-Ft Linear Replacement Lamps Please nte that at the time f this release, lamps intended t replace T5-diameter flurescents are nly eligible in the fur-ft categries. Only lamps intended t replace T8 flurescents are currently eligible in the 2-ft categries. All lamps seeking qualificatin must be tested inside in a reference trffer. Type A, Type B, and Dual-mde tw-ft lamps shall test with three (3) lamps installed in an apprpriate reference trffer. Type C lamps shall test with the apprpriate number f lamps as are intended t be perated n the external driver included in that Type C system; ne, tw, three, and fur lamp Type C systems are eligible. The reference trffer may be any f the fllwing, r a pre-apprved equivalent: Lithnia 2GT8 lensed 2x2 Lithnia 2SP8 lensed 2x2 Lithnia 2PM3 9 cell 2x2 parablic Clumbia Lighting lensed 2x2 4PS22 Clumbia Lighting P222 9 cell 2x2 parablic Pre-apprved equivalent A.L.P. EL-2x2-20-* (*= # f lamps) Saylite 131-A-2-17-E120 Mnmuth Lighting Crp RF24 Simkar Crpratin TY Lensed Trffer 2x2 Testing and Reprting Requirements fr Linear Replacement Lamps Page 6 f 17

7 Jun Lighting Grup S2x2BL LSI LA/FLA 2x2 Clumbia Lighting JT822 Visineering Crp. ERCTB 2x2 US Energy Sciences YTR-02-5 Pre-apprved Equivalents The DLC des nt endrse r exclude any particular make r mdel f reference fixture. Optins listed are intended t illustrate cmmn fixtures f the apprpriate type. Manufacturers may test in alternative fixtures t thse listed, with preapprval frm the DLC. Pre-apprved fixtures must meet the fllwing cnditins: Alternative fixtures must be cmmnly used in the applicatin categry intended fr which they are t be applied. Dcumentatin may be required t demnstrate fixtures apprpriate use if questins arise. Alternative fixtures must prvide similar thermal envirnments t thse listed. Particularly, alternative fixtures may nt be significantly different in internal vlume r cnstructin materials. Table 2: In-situ Testing Perfrmance Requirements: Tw-Ft Linear T8 Replacement Lamps In-situ Lamp Criteria fr Tw-Ft Linear Replacement Lamps Luminaire Efficacy Minimum Initial Luminaire Light Output Spacing Criteria Lumen Maintenance L lm/w 2 lamps installed = 1,350 lm 3 lamps installed = 2,000 lm 4 lamps installed = 2,700 lm Spacing Criteria: = = Znal Lumen Distributin: 0-60 : 75% 50,000 hurs Lumen Maintenance LM-80 fr the package/mdule/array (6,000 hurs minimum) Testing and Reprting Requirements fr Linear Replacement Lamps Page 7 f 17

8 In-situ Temperature Measurement Test (ISTMT) in selected reference luminaire. Type A, Type B, and Dual-mde tw-ft lamps shall test with three (3) lamps installed. Type C lamps shall test with the apprpriate number f lamps as are intended t be perated n the external driver included in that Type C system. TM-21 Calculatr, apprpriately filled ut ( Testing Ntes Fr Replacement Lamps designed t perate utilizing existing flurescent ballasts, testing must be cnducted using a standard 0.88 ballast factr, electrnic instantstart ballast. Specificatin sheets fr the ballasts used during testing must be prvided with the applicatin and the ballast make and mdel number must be nted in the test reprt. Ballasts used in testing must be certified t the applicable safety standards, and must cmply with applicable ANSI standards. Replacement Lamps that utilize rtatable end caps shuld be tested in the rientatin specified as the default in the manufacturer s installatin instructins. If the installatin instructins d nt specify an rientatin, the lamps shuld be riented straight dwn (this is cmmnly the zer degree setting). DLC reviewers will review the installatin instructins prvided with the applicatin t verify the apprpriate testing rientatin, and cmpare this against dcumentatin in the LM-79 reprt and IES file. Rtatable end cap linear replacement lamp listings will include infrmatin n the testing rientatin in the Ntes field. Fixture Level Tests: Three-Ft Linear Replacement Lamps Please nte, at the time f this release, lamps intended t replace T5-diameter flurescents are nly eligible in the fur-ft categries. Only lamps intended t replace T8 flurescents are currently eligible in the 3-ft categries. All lamps seeking qualificatin must be tested inside in a reference strip fixture. Type A, Type B, and Dual-mde three-ft lamps shall test with tw (2) lamps installed in an apprpriate reference fixture. Type C lamps shall test with the apprpriate number f lamps as are intended t be perated n the external driver included in that Type C system; ne r tw lamp Type C systems are eligible. The reference fixture may be any f the fllwing, r a pre-apprved equivalent: Lithnia C 2 25 MVOLT GEB10IS Lithnia Z 2 25 MVOLT GEB10IS Testing and Reprting Requirements fr Linear Replacement Lamps Page 8 f 17

9 Clumbia CS3-225-EU Clumbia CH3-225-EU Pre-apprved equivalent Pre-apprved Equivalents The DLC des nt endrse r exclude any particular make r mdel f reference fixture. Optins listed are intended t illustrate cmmn fixtures f the apprpriate type. Manufacturers may test in alternative fixtures t thse listed, with preapprval frm the DLC. Pre-apprved fixtures must meet the fllwing cnditins: Alternative fixtures must be cmmnly used in the applicatin categry intended t be applied fr. Dcumentatin may be required t demnstrate fixtures apprpriate use if questins arise. Alternative fixtures must prvide similar thermal envirnments t thse listed. Particularly, alternative fixtures may nt be significantly different in internal vlume r cnstructin materials. Table 3: In-situ Lamp Criteria fr Three-Ft Linear Replacement Lamps In-situ Lamp Criteria fr Three-Ft Linear Replacement Lamps Luminaire Efficacy Minimum Initial Luminaire Light Output 100 lm/w 2 lamps installed x 2,200 lm Spacing Criteria Lumen Maintenance L 70 Znal Lumen Distributin: 0-60 : 40% 50,000 hurs Lumen Maintenance LM-80 fr the package/mdule/array (6,000 hurs minimum) In-situ Temperature Measurement Test (ISTMT) in selected reference luminaire. Type A, Type B, Dual-mde and ne-lamp Type-C three-ft lamps shall test with tw (2) lamps installed. Type C lamps shall test with the apprpriate number f lamps as are intended t be perated n the external driver included in that Type C system. TM-21 Calculatr, apprpriately filled ut ( Testing and Reprting Requirements fr Linear Replacement Lamps Page 9 f 17

10 Testing Ntes Fr Replacement Lamps designed t perate utilizing existing flurescent ballasts, testing must be cnducted using a standard 0.88 ballast factr, electrnic instantstart ballast. Specificatin sheets fr the ballasts used during testing must be prvided with the applicatin and the ballast make and mdel number must be nted in the test reprt. Ballasts used in testing must be certified t the applicable safety standards, and must cmply with applicable ANSI standards. Replacement Lamps that utilize rtatable end caps shuld be tested in the rientatin specified as the default in the manufacturer s installatin instructins. If the installatin instructins d nt specify an rientatin, the lamps shuld be riented straight dwn (this is cmmnly the zer degree setting). DLC reviewers will review the installatin instructins prvided with the applicatin t verify the apprpriate testing rientatin, and cmpare this against dcumentatin in the LM-79 reprt and IES file. Rtatable end cap linear replacement lamp listings will include infrmatin n the testing rientatin in the Ntes field. Fixture Level Tests: Fur-Ft Linear Replacement Lamps All T8 and T5 replacement lamps seeking qualificatin must be tested inside a reference trffer. Type A, Type B, and Dual-mde fur-ft lamps shall test with tw (2) lamps installed in an apprpriate reference trffer. Type C lamps shall test with the apprpriate number f lamps as are intended t be perated n the external driver included in that Type C system; ne, tw, three, and fur lamp Type C systems are eligible. The reference trffer may be any f the fllwing, r a pre-apprved equivalent: Lithnia 2GT8 lensed 2x4 (T8 replacements) Lithnia SP5 lensed 2x4 (T5 replacements) Lithnia 2PM3N 12 cell 2x4 parablic (T8 r T5 versin, as apprpriate) Clumbia Lighting lensed 4PS24 (T8 r T5 versin, as apprpriate) Clumbia Lighting P cell parablic (T8 r T5 versin, as apprpriate) Pre-apprved equivalent A.L.P. EL-2x4-23-* (*= # f lamps) Lithnia 2SP8 G 2 32 A12 XXXX XX XXXX Saylite 131-A-2-32-MV Clumbia Lighting 4PS24 Mnmuth Lighting Crp DCP 22 Simkar Crpratin TY Lensed Trffer 2x4 Testing and Reprting Requirements fr Linear Replacement Lamps Page 10 f 17

11 Jun Lighting Grup S2x4BL LSI GA 2x4 Clumbia Lighting JT824 Visineering Crp. ERCTB 2x4 US Energy Sciences YTR-04-7 Philips Day-Brite 2SPG232-FS01-UNV-1/2EB All T5HO replacement lamps seeking qualificatin must be tested inside a reference high bay. Type A, Type B, and Dual-mde fur-ft lamps shall test with fur (4) lamps installed in an apprpriate reference high bay. Type C lamps shall test with the apprpriate number f lamps as are intended t be perated n the external driver included in that Type C system; three, fur, and six lamp Type C systems are eligible. The reference trffer may be any f the fllwing, r a pre-apprved equivalent: Lithnia IBZT5 4 high bay Clumbia Lighting LHA4-4 (T5HO versin) Pre-apprved equivalent Pre-apprved Equivalents The DLC des nt endrse r exclude any particular make r mdel f reference fixture. Optins listed are intended t illustrate cmmn fixtures f the apprpriate type. Manufacturers may test in alternative fixtures t thse listed, with preapprval frm the DLC. Pre-apprved fixtures must meet the fllwing cnditins: Alternative fixtures must be cmmnly used in the applicatin categry intended t be applied fr. Dcumentatin may be required t demnstrate fixtures apprpriate use if questins arise. Alternative fixtures must prvide similar thermal envirnments t thse listed. Particularly, alternative fixtures may nt be significantly different in internal vlume r cnstructin materials. Testing and Reprting Requirements fr Linear Replacement Lamps Page 11 f 17

12 Table 4: In-situ Testing Requirements: Fur-Ft Linear T8, T5, and T5HO Replacement Lamps In-situ Lamp Criteria Fur-Ft Linear T8 and T5 Replacement Lamps Fur-Ft Linear T5HO Replacement Lamps Luminaire Efficacy 100 lm/w 105 lm/w Minimum Initial Luminaire Light Output Spacing Criteria 2 lamps installed = 3,000 lm 3 lamps installed = 4,500 lm 4 lamps installed = 6,000 lm Spacing Criteria: = = Znal Lumen Distributin: 0-60 : 75% 3 lamps installed = 7,500 lm 4 lamps installed = 10,000 lm 6 lamps installed = 15,000 lm Znal Lumen Distributin: : 30% Lumen Maintenance L70 50,000 hurs 50,000 hurs Lumen Maintenance LM-80 fr the package/mdule/array (6,000 hurs minimum) In-situ Temperature Measurement Test (ISTMT) in selected reference luminaire. Type A, Type B, Dual-mde and ne-lamp Type-C fur-ft lamps shall test with tw (2) lamps installed. Type C lamps shall test with the apprpriate number f lamps as are intended t be perated n the external driver included in that Type C system. TM-21 Calculatr, apprpriately filled ut ( Testing Ntes Fr T8 replacement lamps designed t perate utilizing existing flurescent ballasts, testing must be cnducted using a standard 0.88 ballast factr, electrnic instantstart ballast. Specificatin sheets fr the ballasts used during testing must be prvided with the applicatin and the ballast make and mdel number must be nted in the test reprt. Ballasts used in testing must be certified t the applicable safety standards, and must cmply with applicable ANSI standards. Testing and Reprting Requirements fr Linear Replacement Lamps Page 12 f 17

13 Fr T5 and T5HO replacement lamps designed t perate utilizing existing flurescent ballasts, testing must be cnducted using a nrmal 1.0 ballast factr, electrnic prgrammed-start ballast. Specificatin sheets fr the ballasts used during testing must be prvided with the applicatin and the ballast make and mdel number must be nted in the test reprt. Ballasts used in testing must be certified t the applicable safety standards, and must cmply with applicable ANSI standards. Prduct specificatin sheets must clearly indicate fr which specific linear replacement lamp type (i.e. T8, T5, r T5HO) the prduct is intended, and list the base type and nminal length in inches. Replacement Lamps that utilize rtatable end caps shuld be tested in the rientatin specified as the default in the manufacturer s installatin instructins. If the installatin instructins d nt specify an rientatin, the lamps shuld be riented straight dwn (this is cmmnly the zer degree setting). DLC reviewers will review the installatin instructins prvided with the applicatin t verify the apprpriate testing rientatin, and cmpare this against dcumentatin in the LM-79 reprt and IES file. Rtatable end cap linear replacement lamp listings will include infrmatin n the testing rientatin in the Ntes field. Fixture Level Tests: Eight-Ft Linear Replacement Lamps All eight-ft T8 replacement lamps seeking qualificatin must be tested inside a reference strip fixture using an apprpriate integrating sphere. Additinally, using a gniphtmeter, a fur-ft linear replacement lamp with identical cnstructin as half f the eight-ft linear replacement lamp must be tested inside a reference strip fixture. Representative identical fur-ft linear lamps must be a sellable prduct, with a distinct mdel rdering number, that is marketed and prduced by the same manufacturer. Identical linear lamps, while having the base type G13 as utlined in fur-ft lamp requirements, are defined as having the same type and quantity f driver(s), driving the LEDs at the same current, and having the same number f LEDs and PCBs as half f the eight-ft lamp. The representative lamp must als be f identical cnstructin having identical crss-sectins, the same tube material and thickness, and same heatsink material and extrusin. The gniphtmeter testing results frm the fur-ft strip fixture shall be extraplated t represent the eight-ft strip fixture by multiplying the candela f the fur-ft gniphtmeter utput by a scale factr. That factr shall be derived thrugh dividing the tested lumen utput f the eight-ft strip fixture by the tested lumen utput f the fur-ft strip fixture, as btained frm the integrating sphere. Testing and Reprting Requirements fr Linear Replacement Lamps Page 13 f 17

14 The results must meet the in-situ testing requirements in Table 5. Applicants must prvide results frm the eight-ft testing in the integrating sphere, the fur-ft testing in the integrating sphere, and the fur-ft testing in the gniphtmeter. Prduct specificatin sheets fr bth the fur-ft and eight-ft prducts must be submitted with the applicatin. Applicant must als prvide wrkflw demnstrating the calculatin f the scale factr and identifying, within the phtmetric reprt, the candela values derived via calculatin. In additin, a pht f the eight-ft and fur-ft LED layut side-by-side, as well as a crss sectin diagram f cnstructin fr bth prducts must be submitted. Type A, Type B, and dual mde eight-ft lamps shall test with tw (2) lamps installed in an apprpriate reference strip. Type C lamps shall test with the apprpriate number f lamps as are intended t be perated n the external driver included in that Type C system; ne, and tw lamp Type C systems are eligible. The eight-ft reference strip may be any f the fllwing, r a pre-apprved equivalent: Lithnia C 2 96T8 MVOLT GEB10IS Clumbia CS8-296T8-EU Saylite C 259 MV Pre-apprved equivalent The fur-ft reference strip may be any f the fllwing, r a pre-apprved equivalent: Lithnia C 2 32 MV Clumbia CS4-232-EU Saylite C 232 MV Pre-apprved equivalent Pre-apprved Equivalents The DLC des nt endrse r exclude any particular make r mdel f reference fixture. Optins listed are intended t illustrate cmmn fixtures f the apprpriate type. Manufacturers may test in alternative fixtures t thse listed, with preapprval frm the DLC. Pre-apprved fixtures must meet the fllwing cnditins: Alternative fixtures must be cmmnly used in the applicatin categry intended t be applied fr. Dcumentatin may be required t demnstrate fixtures apprpriate use if questins arise. Alternative fixtures must prvide similar thermal envirnments t thse listed. Particularly, alternative fixtures may nt be significantly different in internal vlume r cnstructin materials. Testing and Reprting Requirements fr Linear Replacement Lamps Page 14 f 17

15 Table 5: In-situ Testing Requirements: Eight-Ft Linear T8 Replacement Lamps In-situ Lamp Criteria fr Eight-Ft Linear T8 Replacement Lamps Luminaire Efficacy Minimum Initial Luminaire Light Output Spacing Criteria Lumen Maintenance L lm/w 2 lamps installed = 6,000 lm Znal Lumen Distributin: 0-60 : 40% 50,000 hurs Lumen Maintenance LM-80 fr the package/mdule/array (6,000 hurs minimum) In-situ Temperature Measurement Test (ISTMT) in selected reference luminaire. Type A, Type B, Dual-mde and ne-lamp Type-C eight-ft lamps shall test with tw (2) lamps installed. Type C lamps shall test with the apprpriate number f lamps as are intended t be perated n the external driver included in that Type C system. TM-21 Calculatr, apprpriately filled ut ( Testing Ntes Fr T8 replacement lamps designed t perate utilizing existing flurescent ballasts, testing must be cnducted using a standard 0.88 ballast factr, electrnic instantstart ballast. Ballasts fr each lamp length, including representative identical lamps, shall be determined fr testing based n the apprpriate ballast fr installatin with that lamp length. Specificatin sheets fr the ballasts used during testing must be prvided with the applicatin and the ballast make and mdel number must be nted in the test reprt. Ballasts used in testing must be certified t the applicable safety standards, and must cmply with applicable ANSI standards. Replacement Lamps that utilize rtatable end caps shuld be tested in the rientatin specified as the default in the manufacturer s installatin instructins. If the installatin instructins d nt specify an rientatin, the lamps shuld be riented straight dwn (this is cmmnly the zer degree setting). DLC reviewers will review the installatin instructins prvided with the applicatin t verify the apprpriate testing rientatin, and cmpare this against dcumentatin Testing and Reprting Requirements fr Linear Replacement Lamps Page 15 f 17

16 in the LM-79 reprt and IES file. Rtatable end cap linear replacement lamp listings will include infrmatin n the testing rientatin in the Ntes field. Fixture Level Tests: U-bend Replacement Lamps All lamps seeking qualificatin must be tested inside in a reference trffer. Type A, Type B, and dual mde U-bend lamps shall test with tw (2) lamps installed in an apprpriate reference trffer. Type C lamps shall test with the apprpriate number f lamps as are intended t be perated n the external driver included in that Type C system. The reference trffer may be any f the fllwing, r a pre-apprved equivalent: Lithnia 2GT8 lensed 2x2 Lithnia 2SP8 lensed 2x2 Lithnia 2PM3 9 cell 2x2 parablic Clumbia Lighting lensed 4PS22 Clumbia Lighting P222 9 cell parablic Pre-apprved equivalent A.L.P. EL-2x2-20-* (*= # f lamps) Saylite 131-A-2-32U-E120 Mnmuth Lighting Crp RF24 Simkar Crpratin TY Lensed Trffer 2x2 Jun Lighting Grup S2x2BL LSI LA/FLA 2x2 Clumbia Lighting JT822 Visineering Crp. ERCTB 2x2 US Energy Sciences YTR-02-5 Pre-apprved Equivalents The DLC des nt endrse r exclude any particular make r mdel f reference fixture. Optins listed are intended t illustrate cmmn fixtures f the apprpriate type. Manufacturers may test in alternative fixtures t thse listed, with preapprval frm the DLC. Pre-apprved fixtures must meet the fllwing cnditins: Alternative fixtures must be cmmnly used in the applicatin categry intended t be applied fr. Dcumentatin may be required t demnstrate fixtures apprpriate use if questins arise. Testing and Reprting Requirements fr Linear Replacement Lamps Page 16 f 17

17 Alternative fixtures must prvide similar thermal envirnments t thse listed. Particularly, alternative fixtures may nt be significantly different in internal vlume r cnstructin materials. Table 6: In-situ Testing Requirements: U-bend Linear Replacement Lamps In-situ Lamp Criteria fr U-bend Linear Replacement Lamps Luminaire Efficacy Minimum Initial Luminaire Light Output Spacing Criteria Lumen Maintenance L lm/w 2 lamps installed: 2,500 lm 3 lamps installed: 3,750 lm Spacing Criteria: = = Znal Lumen Distributin: 0-60 : 75% 50,000 hurs Lumen Maintenance LM-80 fr the package/mdule/array (6,000 hurs minimum) In-situ Temperature Measurement Test (ISTMT) in selected reference luminaire. Type A, Type B, Dual-mde and ne-lamp Type-C U-shaped lamps shall test with tw (2) lamps installed. Type C lamps shall test with the apprpriate number f lamps as are intended t be perated n the external driver included in that Type C system. TM-21 Calculatr, apprpriately filled ut ( Testing Ntes Fr Replacement Lamps designed t perate utilizing existing flurescent ballasts, testing must be cnducted using a standard 0.88 ballast factr, electrnic instantstart T8 ballast. Specificatin sheets fr the ballasts used during testing must be prvided with the applicatin and the ballast make and mdel number must be nted in the test reprt. Testing and Reprting Requirements fr Linear Replacement Lamps Page 17 f 17

SECOND DRAFT Testing and Reporting Requirements for Linear Replacement Lamps

SECOND DRAFT Testing and Reporting Requirements for Linear Replacement Lamps SECOND DRAFT Testing and Reprting Requirements fr Nte: This draft represents updates t the existing Testing and Reprting Requirements fr t include 3-ft, 8-ft, and 2G11 base lamps. All changes frm the existing

More information

DRAFT Testing and Reporting Requirements for Linear Replacement Lamps

DRAFT Testing and Reporting Requirements for Linear Replacement Lamps DRAFT Testing and Reprting Requirements fr Linear Replacement Lamps Nte: This draft represents updates t the existing Testing and Reprting Requirements fr Linear Replacement Lamps. All changes frm the

More information

Linear Replacement Lamps

Linear Replacement Lamps Linear Replacement Lamps PLEASE NOTE: DLC DEFINES ALL TUBE-STYLE LED PRODUCTS THAT USE THE LAMP HOLDERS (I.E. SOCKETS OR TOMBSTONES ) IN THE LUMINAIRE TO MECHANICALLY OR ELECTRICALLY CONNECT TO THE FIXTURE

More information

MEDMASTER TROFFER Luminaires for MRI/Imaging Suites LED MRIT SERIES

MEDMASTER TROFFER Luminaires for MRI/Imaging Suites LED MRIT SERIES MEDMASTER TROFFER Luminaires fr MRI/Imaging Suites PRODUCT FEATURES: Recessed munt Grid; 2' 2', 2' 4' Nn-ferrus cnstructin safe fr sensitive MRI equipment High-utput, high-cri LED lamp ptins NSF2 rating

More information

TRUCK AND TRANSPORT MECHANIC STATUTORY DECLARATION OF WORK EXPERIENCE

TRUCK AND TRANSPORT MECHANIC STATUTORY DECLARATION OF WORK EXPERIENCE T qualify t challenge certificatin in this trade r be granted authrity t supervise and sign-ff n apprentices in this trade, individuals must have: wrked a minimum f 9,540 hurs perfrming the tasks listed

More information

The new generation of energy saving tube lighting

The new generation of energy saving tube lighting Lighting The new generatin f energy saving tube lighting MASTER LEDtube EM/Mains The Philips MASTER LEDtube integrates a LED light surce int a traditinal flurescent frm factr. Its unique design creates

More information

Lithium Battery Shipping Overview

Lithium Battery Shipping Overview Lithium batteries are used in many electrnic devices such as cameras, cell phnes, laptp cmputers, medical equipment and pwer tls. When shipping r imprting lithium batteries, including thse cntained in

More information

HIGH POWER RGB LED SERIES. The HB Series Advantage! Architectural Illumination Systems!

HIGH POWER RGB LED SERIES. The HB Series Advantage! Architectural Illumination Systems! The HB Series Advantage SGS listed cnfirming t UL Standard 2108 & 8750 Certified t CSA Standard C22.2 N.9 LED Life f 50K+ hurs, under nrmal perating cnditins Lw wattage, lw heat, lw vltage (12DVC & 24VDC

More information

The new generation of energy saving T8 tube lighting

The new generation of energy saving T8 tube lighting Lighting The new generatin f energy saving tube lighting MASTER LEDtube InstantFit HF Philips MASTER LEDtube InstantFit integrates a LED light surce int a traditinal flurescent frm factr. Its unique design

More information

The best LED solution for High Intensity Discharge (HID) lamp replacement

The best LED solution for High Intensity Discharge (HID) lamp replacement Lighting The best LED slutin fr High Intensity Discharge (HID) lamp replacement TrueFrce LED Public (Urban/Rad HPL/SON) Philips TrueFrce LED lamps prvide an easy LED slutin with a fast payback t replace

More information

Classic heritage design

Classic heritage design Lighting Classic heritage design Classic LEDsptMV Featuring a classic heritage design, Classic LEDsptMV delivers warm halgen-like light while saving arund 90% n energy csts. It is cmpatible with mst existing

More information

Summary of Regulations for Commercial Driver s Licenses from the Federal Motor Carrier Safety Administration (Excerpts 2010)

Summary of Regulations for Commercial Driver s Licenses from the Federal Motor Carrier Safety Administration (Excerpts 2010) Summary f Regulatins fr Cmmercial Driver s Licenses frm the Federal Mtr Carrier Safety Administratin (Excerpts 2010) Classes f License: The Federal standard requires States t issue a CDL t drivers accrding

More information

Low initial investment LED solution provides instant saving while retaining your uniqueness

Low initial investment LED solution provides instant saving while retaining your uniqueness Lighting Lw initial investment LED slutin prvides instant saving while retaining yur uniqueness TrueFrce LED Public (Urban/Rad HPS/MH) Philips TrueFrce LED Public Urban lamps prvide an easy LED slutin

More information

Low initial investment LED solution provides instant saving while retaining your uniqueness

Low initial investment LED solution provides instant saving while retaining your uniqueness Lighting Lw initial investment LED slutin prvides instant saving while retaining yur uniqueness TrueFrce LED Public (Urban/Rad HPS/MH) Philips TrueFrce LED Public Urban lamps prvide an easy LED slutin

More information

NON-ROAD DIESEL EMISSIONS FUEL EFFICIENCY PLAN GUIDELINE VANCOUVER FRASER PORT AUTHORITY

NON-ROAD DIESEL EMISSIONS FUEL EFFICIENCY PLAN GUIDELINE VANCOUVER FRASER PORT AUTHORITY NON-ROAD DIESEL EMISSIONS FUEL EFFICIENCY PLAN GUIDELINE VANCOUVER FRASER PORT AUTHORITY January 31, 2017 VANCOUVER FRASER PORT AUTHORITY Nn-Rad Diesel Emissins Fuel Efficiency Plan Guideline Table f Cntents

More information

The affordable LED solution

The affordable LED solution Lighting The affrdable LED slutin repr LEDtube EM/Mains T8 The repr LEDtube is an affrdable LED slutin suitable fr replacing T8 flurescent lamps. The prduct prvides a natural lighting effect fr use in

More information

BIG-VUE Series Meter

BIG-VUE Series Meter USA SINCE 1936 RELIABILITY BEYOND MEASURE Technical Data Sheet BIG-VUE Series Meter File N. E471457 LAC DU FLAMBEAU,WI LAC DU FLAMBEAU,WI 1/2 The mving irn & mving cil panel meters sizes 2 " 1/2, 3 " are

More information

Model: TM-3 INSTALLATION AND OPERATION INSTRUCTIONS

Model: TM-3 INSTALLATION AND OPERATION INSTRUCTIONS 120 Mdel: TM-3 INSTALLATION AND OPERATION INSTRUCTIONS IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL OR OPERATE INTRODUCTION This Wired Wall Timer system was

More information

TECHNICAL SPECIFICATION. SPC-4T Stirling Process Cryogenerator

TECHNICAL SPECIFICATION. SPC-4T Stirling Process Cryogenerator TECHNICAL SPECIFICATION SPC-4T Stirling Prcess Crygeneratr Reference 80 8044_00 Issue Date April 20, 2016 Stirling Crygenics is a registered trade name f DH Industries BV Fr mre infrmatin n the Stirling

More information

C-BOA Tool Validation of Energy Savings Estimation Methods

C-BOA Tool Validation of Energy Savings Estimation Methods C-BOA Tl Validatin f Energy Estimatin Methds February 21, 2012 1 f 7 Table f Cntents Summary... 3 Recmmendatin... 3 Evaluatin Apprach... 3 Technical Advisry Grup Oversight... 3 Prject Specificatins...

More information

Motorized Pulley 320L, 320M & 320H, Ø in. (321 mm)

Motorized Pulley 320L, 320M & 320H, Ø in. (321 mm) Mtrized Pulley 320L, 320M & 320H, Ø 12.6 in. (321 mm) Our 12.6 diameter Mtrized Pulley range fers three different perfrmance levels fr BULK applicatins: - L fr Light duty - M fr Medium duty - H fr Heavy

More information

PRE-PLANNING & DELIVERY GUIDE

PRE-PLANNING & DELIVERY GUIDE TM PRE-PLANNING & DELIVERY GUIDE Need Assistance? Call 1-888-329-4847 PRE-DELIVERY Spa Delivery Preparatin Yur spa delivery will arrive CURBSIDE at the specified delivery address yu prvided at the time

More information

CIRCULAR LED HIGH BAY

CIRCULAR LED HIGH BAY SPECIFICATION SHEET SUBJECT BLACKSTAR CIR. LED HIGH BAY CUSTOMER PROJECT Prject: Type: Cat. N.: DESCRIPTION Qty: The BLACKSTAR Circular LED High Bay luminaires have a similar lk and feel f the traditinal

More information

Draft ADEM Guidance Proposed Additions to the Alabama UST Regulations

Draft ADEM Guidance Proposed Additions to the Alabama UST Regulations Draft ADEM Guidance Prpsed Additins t the Alabama UST Regulatins Yu may have heard abut upcming changes t the undergrund strage tank regulatins (UST regulatins). On Octber 13, 2015 EPA finalized the first

More information

ADVISORY: General Motors Upfitter Integration Bulletin #108d P a g e 1 May 18, 2016

ADVISORY: General Motors Upfitter Integration  Bulletin #108d P a g e 1 May 18, 2016 Subject: Aftermarket ALDL r DLC Interface Devices Causing Multiple Issues Mdels All Passenger Cars and Trucks Affected: Mdel Years: 2006 and beynd Date: February 4, 2013 Revisin Date: May 18, 2016 ADVISORY:

More information

Technical Manual. eluma. Aluminum Frame LED Panels. patents pending. Technical Specifications Subject to Change

Technical Manual. eluma. Aluminum Frame LED Panels. patents pending. Technical Specifications Subject to Change Technical Manual eluma Aluminum Frame LED Panels patents pending TM Technical Specificatins Subject t Change TABLE OF CONTENTS General Specificatins.. Page 3 Prfile Specificatins EL001.. Page 4 Prfile

More information

TECHNICAL STANDARD ORDERS (TSO) CERTIFICATION CONSIDERATION IN CHINA FOR INTEGRATED MODULAR AVIONICS (IMA) HARDWARE ELEMENTS

TECHNICAL STANDARD ORDERS (TSO) CERTIFICATION CONSIDERATION IN CHINA FOR INTEGRATED MODULAR AVIONICS (IMA) HARDWARE ELEMENTS TECHNICAL STANDARD ORDERS (TSO) CERTIFICATION CONSIDERATION IN CHINA FOR INTEGRATED MODULAR AVIONICS (IMA) HARDWARE ELEMENTS Presented By: Frank(Fei) Xia, AVIAGE SYSTEMS Date: April 21, 2016 ABOUT AVIAGE

More information

Traffic Logix SafePace 400 Radar Speed Sign Product Specifications Version 1.2

Traffic Logix SafePace 400 Radar Speed Sign Product Specifications Version 1.2 Traffic Lgix SafePace 400 Radar Speed Sign Prduct Specificatins Versin 1.2 Traffic Lgix Crp. I 3 Harriet Lane I Spring Valley, New Yrk 10977 T (866) 915-6449 F (866)995-6449 I www.trafficlgix.cm I inf@trafficlgix.cm

More information

ABTQ-103 rev 01 Last review:

ABTQ-103 rev 01 Last review: INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR ABTECH PCS Cntrl Statin Purpse f Instructins Wrking in hazardus areas, the safety f persnnel and plant depends n cmplying with all relevant safety

More information

Update on Emerging Technologies of the RfG

Update on Emerging Technologies of the RfG An Cimisiún um Rialáil Fóntas Cmmissin fr Regulatin f Utilities Update n Emerging Technlgies f the RfG Reprting Perid May July 2018 Infrmatin Paper Reference: CRU18223 Date Published: 1/10/2018 Clsing

More information

Introduction Specifications Structure & Performance Assembly Folding Operation Care & Maintenance...

Introduction Specifications Structure & Performance Assembly Folding Operation Care & Maintenance... n Intrductin... 3 Specificatins... 4 Structure & Perfrmance... 5 Assembly... 6 Flding... 7 Operatin... 8-12 Care & Maintenance... 13-15 2 P a g e Read and fllw all instructins, warnings, and ntes in this

More information

Update on Emerging Technologies of the RfG

Update on Emerging Technologies of the RfG An Cimisiún um Rialáil Fóntas Cmmissin fr Regulatin f Utilities Update n Emerging Technlgies f the RfG Reprting Perid March May 2018 Infrmatin Paper Reference: CRU/18/121 Date Published: 26/07/2018 Clsing

More information

efficiently illuminating your way Technical Datasheet High efficiency LED retro lights

efficiently illuminating your way Technical Datasheet High efficiency LED retro lights efficiently illuminating yur way Aerlite LRL High efficiency LED retr lights www.grahlighting.cm Setting new standards in LED lighting AEROLITE family is a grup f currently ne f the mst advanced street

More information

REQUEST FOR QUALIFICATIONS FOR ENGINEERING SERVICES RELATED TO SALEM BIKE-PED CORRIDOR PHASE 2 DESIGN AND CONSTRUCTION SUPERVISION

REQUEST FOR QUALIFICATIONS FOR ENGINEERING SERVICES RELATED TO SALEM BIKE-PED CORRIDOR PHASE 2 DESIGN AND CONSTRUCTION SUPERVISION REQUEST FOR QUALIFICATIONS FOR ENGINEERING SERVICES RELATED TO SALEM BIKE-PED CORRIDOR PHASE 2 DESIGN AND CONSTRUCTION SUPERVISION The Twn f Salem, New Hampshire is requesting qualificatins frm qualified

More information

Annex to the EU Type-Examination Certificate No. EU-BD 758 of

Annex to the EU Type-Examination Certificate No. EU-BD 758 of Annex t the EU Type-Examinatin Certificate N. EU-BD 758 f 2016-04-01 1 Scpe f applicatin 1.1 Use as braking device part f the the prtectin device against verspeed fr the car mving in upwards directin permissible

More information

Traffic Logix SafePace 475 Radar Speed Signs Product Specifications Version 1.2

Traffic Logix SafePace 475 Radar Speed Signs Product Specifications Version 1.2 Traffic Lgix SafePace 475 Radar Speed Signs Prduct Specificatins Versin 1.2 1 Table f Cntents Dimensins... 3 Sign Weight... 3 Accessries... 3 Technical Specificatins... 4 Pwer... 4 Radar... 4 Display...

More information

Franchised Hauler Exemption for Recycling Application

Franchised Hauler Exemption for Recycling Application Franchised Hauler Exemptin fr Recycling Applicatin City f Ann Arbr Franchised Hauler Exemptin fr Recycling Applicatin Exemptins frm cmmercial trash services prvided by the city-selected franchised hauler

More information

Update on Emerging Technologies of the RfG

Update on Emerging Technologies of the RfG An Cimisiún um Rialáil Fóntas Cmmissin fr Regulatin f Utilities Update n Emerging Technlgies f the RfG Reprting Perid July 2017 Infrmatin Paper Reference: CRU17326 Date Published: 27/11/2017 Clsing Date:

More information

CERTIFICATE OF APPROVAL No CF 119 DORMA UK LTD

CERTIFICATE OF APPROVAL No CF 119 DORMA UK LTD CERTIFICATE OF APPROVAL N CF 119 1 This is t certify that, in accrdance with TS00 General Requirements fr Certificatin f Fire Prtectin Prducts The undermentined prducts f Wilbury Way, Hitchin, Hertfrdshire

More information

Gearbox Installation Manual

Gearbox Installation Manual Gearbx Installatin Manual Rtrk Gears HOB/MPR & HOS/MPR ranges (Electrnic cpy available n www.rtrk.cm)! This manual cntains imprtant safety infrmatin. Please ensure it is thrughly read and understd befre

More information

Traffic Logix SafePace 475 Radar Speed Signs Product Specifications Version 1.0

Traffic Logix SafePace 475 Radar Speed Signs Product Specifications Version 1.0 Traffic Lgix SafePace 475 Radar Speed Signs Prduct Specificatins Versin 1.0 1 Table f Cntents Dimensins... 3 Sign Weight... 3 Accessries... 3 Technical Specificatins... 4 Pwer... 4 Radar... 4 Display...

More information

The new generation of energy-saving LED PLC tube lighting

The new generation of energy-saving LED PLC tube lighting Lighting The new generatin f energy-saving LED PLC tube lighting Philips is the ideal uplamping slutin fr dwnlights in a wide range f general lighting applicatins. It integrates a LED light surce int a

More information

Temporary Use and Vendor Stand Online Permit Submittal

Temporary Use and Vendor Stand Online Permit Submittal Temprary Use and Vendr Stand Online Permit Submittal A Temprary Use Permit is an pen-air small business that is there fr a limited time fr the uses listed belw. Temprary Use Duratin Extensin Agricultural

More information

INVERTER/CHARGERS EVOLUTION SERIES. Off-Grid Power Solutions. How an Inverter/ Charger. Works... ORDER NOW

INVERTER/CHARGERS EVOLUTION SERIES. Off-Grid Power Solutions. How an Inverter/ Charger. Works... ORDER NOW D yu yu need reliable AC pwer in a vehicle, remte lcatin r fr emergency back-up? Samlex s inverter/charger is THE chice fr a cmplete ff-grid pwer slutin. Off-Grid Pwer Slutins LUTION SERIES S Sine 1 Pure

More information

Essential LEDtube - Affordable LED solution

Essential LEDtube - Affordable LED solution Lighting Essential LEDtube - Affrdable LED slutin Essential LEDtube Essential LEDtube is an affrdable LED tube that is suitable fr replacing T8 flurescent lamps. The prduct prvides a natural lighting effect

More information

/2017. Flexline rapid clamping systems with drive chain clamping element, T-slot and adjustment track

/2017. Flexline rapid clamping systems with drive chain clamping element, T-slot and adjustment track Traveling unit chain (adjustment track) in 3 lengths s in varius designs Mtr Advantages 8 different clamping elements 4 different T-slts 3 different adjustment tracks drive mtr and die mnitr attachable

More information

General Faucet Installation Instructions

General Faucet Installation Instructions General Faucet Installatin Instructins Step 1: Psitin the Faucet Begin installing yur faucet by placing the gasket and faucet in psitin n the sink. (Diagram A) Frm under the sink, thread the plastic munting

More information

Diagram1- typical B-Triple. Diagram 2 typical AB-Triple. Diagram 3 typical Road Train

Diagram1- typical B-Triple. Diagram 2 typical AB-Triple. Diagram 3 typical Road Train NSW ROAD TRAIN MODERNISATION PROGRAM B-TRIPLE & AB-TRIPLE OPERATING CONDITIONS Applicatin These perating cnditins apply t: B-Triples, which are a vehicle cmbinatin cnsisting f a prime mver twing three

More information

Traffic Logix SafePace 450 (Full & Compact) Radar Speed Signs Product Specifications Version 1.6

Traffic Logix SafePace 450 (Full & Compact) Radar Speed Signs Product Specifications Version 1.6 Traffic Lgix SafePace 450 (Full & Cmpact) Radar Speed Signs Prduct Specificatins Versin 1.6 2014-2016 Traffic Lgix Crpratin www.tapcnet.cm 5100 West Brwn Deer Rad Brwn Deer, WI 53223 1 Table f Cntents

More information

PLANNING MEETINGS CHEFS, AWGIC AND HOST SOCIETY

PLANNING MEETINGS CHEFS, AWGIC AND HOST SOCIETY Planning Meetings PLANNING MEETINGS CHEFS, AWGIC AND HOST SOCIETY The Arctic Winter Games Internatinal Cmmittee (AWGIC) establishes a series f planning meetings with each Hst Sciety and Chefs de Missin

More information

FC Sıcaklık Serisi FLAMEPROOF SWITCHES. IECEx CoC

FC Sıcaklık Serisi FLAMEPROOF SWITCHES. IECEx CoC FLAMEPROOF SWITCHES SPECIFIER'S GUIDE FOR PRESSURE SWITCHES PRESSURE DIFFERENCE SWITCHES VACUUM SWITCHES TEMPERATURE SWITCHES APPROVED with IECEx CC CCOE apprved KLPL apprved FC Sıcaklık Serisi 7 Using

More information

Essential LEDtube - Affordable LED solution

Essential LEDtube - Affordable LED solution Lighting Essential LEDtube - Affrdable LED slutin Essential LEDtube Essential LEDtube is an affrdable LED tube that is suitable fr replacing T8 flurescent lamps. The prduct prvides a natural lighting effect

More information

PRAIRIE 360 4X4 (KVF360-A/C), PRAIRIE 360 2X4 (KVF360-B), PRAIRIE 650 4X4 (KVF650-A/B), PRAIRIE 700 4X4 (KVF700-A/B/D),

PRAIRIE 360 4X4 (KVF360-A/C), PRAIRIE 360 2X4 (KVF360-B), PRAIRIE 650 4X4 (KVF650-A/B), PRAIRIE 700 4X4 (KVF700-A/B/D), SERVICE REPLACES: Please discard ATV 07-02 dated 4/5/07 MODEL: PRAIRIE 360 4X4 (KVF360-A/C), PRAIRIE 360 2X4 (KVF360-B), PRAIRIE 650 4X4 (KVF650-A/B), PRAIRIE 700 4X4 (KVF700-A/B/D), KFX700 (KSV700-A/B/C),

More information

Genesys Certification Study Guide

Genesys Certification Study Guide Genesys Certificatin Study Guide Genesys Certified Prfessinal 8 System Cnsultant, iwd Slutin (GCP8 - CiWD) Exam Cde Type f Exam Number f Items GCP8-CiWD (Prmetric cde: GE0_809) Written, multiple-chice

More information

Webinar: Ontario s 2012 Building Code: Electric Vehicle Charging. Presented by the Ministry of Municipal Affairs

Webinar: Ontario s 2012 Building Code: Electric Vehicle Charging. Presented by the Ministry of Municipal Affairs Webinar: Ontari s 2012 Building Cde: Electric Vehicle Charging Presented by the Ministry f Municipal Affairs Ntice This presentatin is intended fr general infrmatin purpses related t electric vehicle charging

More information

Create a warm, welcoming ambience with superior quality lighting

Create a warm, welcoming ambience with superior quality lighting Lighting Create a warm, welcming ambience with superir quality lighting MASTER LEDspt MV ExpertClr creates a warm and cmfrtable ambience fr hspitality venues, hmes and restaurants It creates such an ambience

More information

TCL Air Cooled Condensers

TCL Air Cooled Condensers PRODUCT DATA & INSTALLATION Bulletin T50-TCL-PDI-6 Part # 1089597 PRODUCT SUPPORT web: t-rp.cm/tcl email: acc-fc@t-rp.cm call: 1-844-893-3222 x526 scan: TCL Air Cled Cndensers One t Furteen Fan Mtrs R407A

More information

CASTLE ROCK BUSINESS AND DEVELOPMENT INCENTIVE PROGRAM

CASTLE ROCK BUSINESS AND DEVELOPMENT INCENTIVE PROGRAM CASTLE ROCK BUSINESS AND DEVELOPMENT INCENTIVE PROGRAM PROGRAM OVERVIEW Ecnmic Vitality is a critical factr in ensuring Castle Rck s lng-term success and in achieving its Visin f being a Self-Sufficient

More information

Ideal for HPI/SON/HPL LED replacement in Highbay application

Ideal for HPI/SON/HPL LED replacement in Highbay application Lighting Ideal fr HPI/SON/HPL LED replacement in Highbay applicatin TrueFrce LED Industrial and Retail (Highbay HPI/SON/HPL) Philips TrueFrce LED Industrial and Retail lamps give yu a quick and easy payback

More information

Pre-Planning Delivery Guide

Pre-Planning Delivery Guide Pre-Planning Delivery Guide Need Assistance? Call 1-888-768-6772 Pre-Delivery Spa Delivery Preparatin Yur spa delivery will arrive CURBSIDE at the specified delivery address yu prvided at the time f yur

More information

Safe Handling of High Voltage Electrical components in Electrical End of Life Vehicles

Safe Handling of High Voltage Electrical components in Electrical End of Life Vehicles Safe Handling f High Vltage Electrical cmpnents in Electrical End f Life Vehicles The fllwing infrmatin is extracted frm the dcument Safe Handling f High Vltage Electrical cmpnents in Electrical End f

More information

Prepared By: Lisa McAvoy 28/Nov/17 dd/mmm/yy. Approved By: Veronica Harris-McAllister 30/Nov/17 dd/mmm/yy

Prepared By: Lisa McAvoy 28/Nov/17 dd/mmm/yy. Approved By: Veronica Harris-McAllister 30/Nov/17 dd/mmm/yy Standard Operating Prcedure Otscpes and Ophthalmscpes SOP Number: SOP-OO-01.1 Categry: Lab Prcess Supersedes: SOP-OO-01 Effective Date: December 1, 2017 Pages 7 Subject: Otscpes and Ophthalmscpes Prepared

More information

Hub/Remote Operations in version 3.0

Hub/Remote Operations in version 3.0 Hub/Remte Operatins in versin 3.0 In StckTrac Enterprise 3.0, the Hub and Remte perate quite a bit differently than they did in 2.0. In 2.0, the shps stred their business fr the day int daily files which

More information

{EMS Shock} Student Name: Period:

{EMS Shock} Student Name: Period: {EMS Shck} Student Name: Perid: 5 th Grade Engineering Pulleys Unit Rubric Lab #0016 Pulley Frame Pulley Frame: Student cnstructed the Pulley Frame t lab specificatins. Pulley Frame was nt apprved 0 pints

More information

SAE Certified Vehicle Electrification Professional

SAE Certified Vehicle Electrification Professional SAE Certified Vehicle Electrificatin Prfessinal Bdy f Knwledge fr the CVEP Secnd Editin Table f Cntents Intrductin... 2 CVEP Examinatin Structure... 4 Essential Safety Examinatin... 4 Knwledge-based Examinatin...

More information

72 Mustang Mach 1 tachometer cluster and gauge conversion

72 Mustang Mach 1 tachometer cluster and gauge conversion 72 Mustang Mach 1 tachmeter cluster and gauge cnversin Dated: 02-17-2009 (drafted by a Chevy persn wrking n his first Frd -nt gd-) The fllwing infrmatin pertains t hw I went abut cnverting the standard

More information

21 Econo Place, Silverdale, NSW 2752 P F SPAN TABLES

21 Econo Place, Silverdale, NSW 2752 P F SPAN TABLES 21 Ecn Place, Silverdale, NS 2752 P 1300 132 787 F 02 4774 2679 www.quickbuiltsystems.cm.au SPAN TABLES ROSS Engineers have prepared these tables fr use by peple skilled in the design and specificatin

More information

100 KW / 125 KVA POWERED by

100 KW / 125 KVA POWERED by 100 KW / 125 KVA POWERED by MODEL Tritn Pwer is a wrld leader in the design, manufacture f statinary, mbile and rental generatr sets and Pwer Mdules frm 10 t 2000 kw. Thrugh ur cmmitment t quality we manufacture

More information

SERVICE FACTORY DIRECTED MODIFICATION MC IMMEDIATE INSPECTION REPAIR ONLY AS REQUIRED ENGINE PULLEY WEAR

SERVICE FACTORY DIRECTED MODIFICATION MC IMMEDIATE INSPECTION REPAIR ONLY AS REQUIRED ENGINE PULLEY WEAR SERVICE REPLACES: Please discard MC 06-07 dated June 27, 2006 MODEL: 2004-2005 VULCAN 2000 (VN2000-A1/L-A2/L) MC 06-07 Date: July 28, 2006 First Issued: June 27, 2006 Page 1 f 7 TITLE: ENGINE PULLEY WEAR

More information

Elegance meets efficiency

Elegance meets efficiency Lighting Elegance meets efficiency MASTER LEDbulbs The MASTER LEDbulb range delivers a dimmable glw effect fr a welcming, warm atmsphere, making it ideal fr general lighting applicatins in the hspitality

More information

Design Standard - Fume Hoods & Fume Hood Exhausts

Design Standard - Fume Hoods & Fume Hood Exhausts 1.0 Intrductin Design Standard - Fume Hds & Fume Hd Exhausts The fume hd is the primary cntrl device in mst labratries fr prtecting emplyees and students frm expsure t hazardus chemicals. It is als an

More information

EnergyBar 6. Setup Guide

EnergyBar 6. Setup Guide EnergyBar 6 Setup Guide WELCOME Cngratulatins n yur purchase f the Apex EnergyBar 6! The EnergyBar 6 allws the Apex system t cntrl up t six 230 vlt items such as lights, pumps, fans, heaters, chillers

More information

VEHICLE ACTIVATED SPEED LIMIT SIGNS

VEHICLE ACTIVATED SPEED LIMIT SIGNS VEHICLE ACTIVATED SPEED LIMIT SIGNS TRS-VASL VEHICLE ACTIVATED SPEED LIMIT SIGNS Vehicle Activated Speed Limit (VASL) signs measure the speed f appraching vehicles. If the speed f the vehicle is higher

More information

Transport Research Laboratory Creating the future of transport

Transport Research Laboratory Creating the future of transport Transprt Research Labratry Creating the future f transprt CLIENT PROJECT REPORT CPR2188 Survey f vehicle radwrthiness f HCVs and driver cmpliance with EU rules n driving times, breaks and rest perids -

More information

TAFE Digital Application Form for Certificate III UEE30811 Electrotechnology Electrician

TAFE Digital Application Form for Certificate III UEE30811 Electrotechnology Electrician ELECTROTECHNOLOGY - CERT III ELECTRICIAN Natinal cde: UEE30811 Training package: UEE11 TAFE Digital Applicatin Frm fr Certificate III UEE30811 Electrtechnlgy Electrician OFFICE USE ONLY Date received:

More information

Proposed Changes to Ontario s Building Code Summer and Fall 2017 Consultation: Electric Vehicle Charging in Multi-Unit Residential Buildings

Proposed Changes to Ontario s Building Code Summer and Fall 2017 Consultation: Electric Vehicle Charging in Multi-Unit Residential Buildings Prpsed Changes t Ontari s Building Cde Summer and Fall 2017 Cnsultatin: Electric Vehicle Charging in Multi-Unit Residential Buildings Purpse T prvide infrmatin n prpsed changes t the Building Cde regarding

More information

Smart Look Series Meter

Smart Look Series Meter File N. E471457 Technical Data Sheet Smart Lk Series Meter 1/2 The mving irn & mving cil panel meters sizes 2 " 1/2, 3 " are hused in a mulded plycarbnate cases which are suitable fr the measurement f

More information

SUBARU 5 YEAR/125,000 KILOMETRE SERVICE PLAN PROGRAM TERMS & CONDITIONS

SUBARU 5 YEAR/125,000 KILOMETRE SERVICE PLAN PROGRAM TERMS & CONDITIONS SUBARU 5 YEAR/125,000 KILOMETRE SERVICE PLAN PROGRAM TERMS & CONDITIONS Under the Subaru 5 Year/125,000 Kilmetre Service Plan ( Service Plan ) wners f eligible Subaru vehicles are cvered fr scheduled servicing

More information

Installation Guide Contigo 6100

Installation Guide Contigo 6100 Installatin Guide Cmmercial Vehicle Prductivity and Security The is a high-perfrmance beacn designed fr cmmercial prductivity and security. It is ideally suited t installatins in delivery and service fleets

More information

ADDENDUM NO. 1 REQUEST FOR PROPOSAL NO CLOSING DATE: September 14, 2012, 12:00 NOON (LOCAL TIME)

ADDENDUM NO. 1 REQUEST FOR PROPOSAL NO CLOSING DATE: September 14, 2012, 12:00 NOON (LOCAL TIME) Michael Pachlk (Acting) Directr Purchasing & Materials Management Divisin City Hall 100 Queen Street West 18 th Flr, West Twer Trnt, Ontari M5H 2N2 Elena Carus, Manager Gds and Services August 28, 2012

More information

PSS INSTALLATION INSTRUCTIONS

PSS INSTALLATION INSTRUCTIONS PSS INSTALLATION INSTRUCTIONS Imprtant - Read Befre Starting! Befre starting yur installatin carefully read the fllwing warnings and instructins. Failure t prperly fllw the warnings and instructins culd

More information

Methanol Recovery Systems

Methanol Recovery Systems Methanl Recvery Systems Methanl Recvery fr bidiesel is an imprtant part f the entire bidiesel prcess and invlves the highest cst f peratin fr a bidiesel plant. Only abut half f the methanl used is actually

More information

The MODUM Fire Escape Ladder

The MODUM Fire Escape Ladder The MODUM Fire Escape Ladder The MODUM Fire Escape Ladder is elegantly designed fr permanent wall munting - and it is ready fr use in secnds. The MODUM Fire Escape Ladder is designed and manufactured in

More information

You have a Chiller, Now What?

You have a Chiller, Now What? Yu have a Chiller, Nw What? Raschell Hickmtt Reginal Sales Manger Dimplex Thermal Slutins Klant Klers Brand Chillers Agenda This presentatin is develped t be a very brief and generic intrductin t anyne

More information

Volume 1.1 OPERATIONAL MANUAL MODEL: CG-211Y PIPE TORCH/BURNER MACHINE. by BLUEROCK Tools

Volume 1.1 OPERATIONAL MANUAL MODEL: CG-211Y PIPE TORCH/BURNER MACHINE. by BLUEROCK Tools Vlume 1.1 OPERATIONAL MANUAL MODEL: CG-211Y PIPE TORCH/BURNER MACHINE by BLUEROCK Tls UNPACKING THE ITEM Cautin: This machine is packed tgether with items that may be sharp, ily and verly heavy bjects.

More information

BHC-P-11.1 Temporary Works

BHC-P-11.1 Temporary Works Berkeley Hme Cunties Safety Prcedures Cntents 1.0 Purpse 2.0 Scpe 3.0 Definitins 4.0 Main requirements 5.0 Guidance dcuments and references 6.0 Appendices Revisin register BHC-P-11.1 Temprary Wrks Date

More information

BC7 BATTERY CABINET INSTALLATION / OPERATION / MAINTENANCE

BC7 BATTERY CABINET INSTALLATION / OPERATION / MAINTENANCE BC7 BATTERY CABINET INSTALLATION / OPERATION / MAINTENANCE 1. INTRODUCTION... 3 2. PRECAUTIONS... 3 3. INSPECTION UPON RECEIPT OF GOODS... 4 3.1 GENERAL... 4 3.2 VISIBLE DAMAGE... 4 3.3 CONCEALED DAMAGE...

More information

The new generation of energy-saving LED PLC tube lighting

The new generation of energy-saving LED PLC tube lighting Lighting The new generatin f energy-saving LED PLC tube lighting CrePr LED PLC Philips CrePr LED PLC is the ideal uplamping slutin fr dwnlights in a wide range f general lighting applicatins. It integrates

More information

Idaho: Idaho revised vehicle code:

Idaho: Idaho revised vehicle code: Idah: Idah revised vehicle cde: http://www.legislature.idah.gv/idstat/title49/t49.htm (6) "Trailer" means: (a) General. Every vehicle withut mtive pwer designed fr carrying persns r prperty and fr being

More information

WORLD COAL AUGUST VOLUME 20 NUMBER World Leader in Material Handling and Coal Preparation

WORLD COAL AUGUST VOLUME 20 NUMBER World Leader in Material Handling and Coal Preparation WORLD COAL AUGUST 2011 AUGUST 2011 - VOLUME 20 NUMBER 08 www.energyglbal.cm Wrld Leader in Material Handling and Cal Preparatin Smth peratins, n s r a L d i v Da., C n t r e t s e A.W. Chnes a simple US,

More information

EZYTrigger. Sales and Distribution Europe. Active Trigger units for firing Power Thyristors

EZYTrigger. Sales and Distribution Europe. Active Trigger units for firing Power Thyristors Active Trigger units fr firing Pwer Thyristrs Sales and Distributin Eurpe Tel.: +49 (0)2432 49677 Fax: +49 (0)2432 49656 Mail: inf@amelectrnic.de www.amelectrnic.de Active Trigger units fr firing Pwer

More information

Motorized Pulley 165E, Ø 165 mm

Motorized Pulley 165E, Ø 165 mm Mtrized Pulley 165E, Ø 165 mm Mtrized Pulley 165E, with machined helical gear b, perfrms an efficiency, in a cmpact diameter f 165 mm nly. With a min RL f 400 mm and and pwers ranging frm 0.11kW t 1.5kW

More information

Parts Checklist: XJ Front 3-Link Long Arm Upgrade Installation Instructions *BOX 1* *BOX 2* Jeep Cherokee XJ

Parts Checklist: XJ Front 3-Link Long Arm Upgrade Installation Instructions *BOX 1* *BOX 2* Jeep Cherokee XJ XJ Frnt 3-Link Lng Arm Upgrade Installatin Instructins 84-01 Jeep Cherkee XJ Parts Checklist: *BOX 1* Instructins Invice Lg decal 10001 (1) Rck-Link decal 13287 (2) Irnrckffrad.cm decal (1) Subframe center

More information

Installation Guide Contigo 6150 & 6151

Installation Guide Contigo 6150 & 6151 Installatin Guide Cntig 6150 & 6151 Cmmercial Vehicle Prductivity and Security The Cntig 6150 & 6151* (cllectively knwn as the Cntig 615X) are highperfrmance beacns designed fr cmmercial prductivity and

More information

Dana Spicer Driveshaft. Installation Guide DSIG-3311 March 2004

Dana Spicer Driveshaft. Installation Guide DSIG-3311 March 2004 Dana Spicer Driveshaft Installatin Guide DSIG-3311 March 2004 Safety Precautins General Safety Infrmatin T prevent injury t yurself and /r damage t the equipment: Read carefully all wners manuals, service

More information

EDBRO RIGID INCLINOMETER

EDBRO RIGID INCLINOMETER EDBRO RIGID INCLINOMETER RINC01 Installatin & Operating Instructins E5542 rev 1 (June 2010) Edbr PLC Nelsn Street, Bltn BL3 2JJ UK Tel: +44 (0) 120 4528888 Fax: +44 (0) 120 4531957 E-mail: pstmaster@edbr.cm

More information

FIRST: Top battery (closest to the arm) SECOND: Middle battery. LAST: Top battery (furthest from arm)

FIRST: Top battery (closest to the arm) SECOND: Middle battery. LAST: Top battery (furthest from arm) Hw t Install the Batteries Hw t Hld the Lamp: The InteliEnergy Lamp selectin switches utilize the same technlgy as cell phnes: Capacitive Tuch. This assures the ultimate in lngevity because there are n

More information

MASTER LEDbulb - Elegence meets efficiency

MASTER LEDbulb - Elegence meets efficiency Lighting MASTER LEbulb - Elegence meets efficiency MASTER LEbulb MASTER LEbulb range delivers a dimmable glw effect fr a welcming, warm atmsphere, making it ideal fr general lighting applicatins in the

More information

WELCOME. WEB LOCATION Los Angeles, CA

WELCOME. WEB   LOCATION Los Angeles, CA WELCOME Thank yu fr chsing AC Infinity. We are cmmitted t prduct quality and friendly custmer service. If yu have any questins r suggestins, please dn t hesitate t cntact us. Visit www.acinfinity.cm and

More information

Uninterruptible Current Supply USV V / 1.2 Ah

Uninterruptible Current Supply USV V / 1.2 Ah Uninterruptible Current Supply USV 011 +24 V / 1.2 Ah The USV 011 Uninterruptible current supply is used t buffer the +24 V supply f an Industry PC (C-IPC, SIPC). The +24 V supply is nrmally cnnected t

More information