ELEKTROMATEN ST Sliding-door-drive
|
|
- Cori Stone
- 6 years ago
- Views:
Transcription
1 ST Sliding-door-drive for sliding doors ST 9.5 ST 80. Output torque: Nm Output speed: 5 - rpm Control panels for ST WS 905 / TS Subject to alterations. (_Db).000
2
3 ST Sliding-door-drive For driving: Sliding-doors Series SG50R ST 9.5 ST 9. Series ST 6.5 ST 0. Series SG5R ST 60.5 ST 80. ST are special drives for sliding-doors designed for industrial use. ST comprises of: Worm gear with integrated friction clutch, interchangeable output-shaft, magnetic brake (optional), emergency manual operation (optional), integrated limit switch (optional), mounting accessories and electrical motor. Output side: The interchangeable output-shaft allows easy modification from left- to right-hand use. Friction clutch: The integrated friction clutch guarantees impact-damped, low-wear operation. Magnetic brake (optional): Ensures precise positioning of the door limit position, slightly heating ensures trouble-free operation at low outside temperatures. Integrated limit switch (optional): No need of separate limit switches SG50R Approvals and certificates Type test according to: DIN EN 5 DIN EN 605- DIN EN SG5R Emergency manual operation (optional) E.g.: for top-hung sliding doors Hand crank NHK Hand chain operator KNH Limit switch integrated (optional) Mechanical limit NES operating, emergency- and auxiliary limit switches Digital limit DES Absolute encoder, after a power failure, re-adjustment is not required Separate limit switch (optional) Roller-arm limit switch Inductive limit switch Mounting Foot angle (standard fitting) Mounting base Special versions Increase of movements per hour Other voltages and frequencies ST-TRK: Sliding-door with magnetic brake ST-SI: Sliding-door with integrated safety brake, e.g. for sliding doors operating on an incline Door controls Simple connection to the limit switch by means of non-interchangeable plug connections allowing simple exchange with other GfA control panels Control voltage: V Frequency: 50 / 60 Hz Supply voltage: N~0V, ~0V, N~00V, ~00V Details of all GfA door controls for sliding doors can be found from page.0. Subject to alterations. (_Cf).0
4 . Technical data Series ST 9.5 SG50R ST 9. SG50R ST 6.5 ST 6. ST 0.5 Output torque Output speed Max. door weigth Door speed Output shaft / hollow shaft (Ø) Permitted OPEN / CLOSE output speed in frequency-inverter operating mode Motor power Supply voltage Operating frequency Operating current Max. movements per hour 5 Supply side wiring fusing (delayed-action) Limit switch range 6 Weight Spare parts: Catalogue page Part no. installation drawing (dxf, dwg) Part no. Nm rpm N cm/ sec mm rpm kw V - Hz Hz A kg / 6 / 6 / 6 / 6 / 6 0,0 0,7 0,55 0,0 0,75 ~0 / 00V ~0 / 00V ~0 / 00V ~0 / 00V ~0 / 00V ,6 /,5, /,, /,8, /,8 5, /, x,5² / 0A 5x,5² / 0A 5x,5² / 0A 5x,5² / 0A 5x,5² / 0A 0 / 0 0 / 0 0 / 0 0 /0 0 / Series ST 0. ST 60.5 SG5R ST 60. SG5R ST 80.5 SG5R ST 80. SG5R Output torque Output speed Max. door weigth Door speed Output shaft / hollow shaft (Ø) Permitted OPEN / CLOSE output speed in frequency-inverter operating mode Motor power Supply voltage Operating frequency Operating current Max. movements per hour 5 Supply side wiring fusing (delayed-action) Limit switch range 6 Weight Spare parts: Catalogue page Part no. installation drawing (dxf, dwg) Part no. Nm rpm N cm/ sec mm rpm kw V - Hz Hz A kg / 6 / 6 / 6 / 6 / 0,85,0,50,0,00 ~0 / 00V ~0 / 00V ~0 / 00V ~0 / 00V ~0 / 00V , /,6 7, /, 6,7 /,9 7,0 /, 8, /, x,5² / 0A 5x,5² / 0A 5x,5² / 0A 5x,5² / 0A 5x,5² / 0A 0 / 0 0 / 60 0 /60 0 / 60 0 / Generally applies: Protection class IP5, permissible temperature range -0 C...+0 C (+60 C), from -0 C in combination with a permanently used magnetic brake, operating sound pressure level SPL 70 db(a) See.6 Door speed when operated with standard chain wheel, see 5. We recommend the selection of a special (enquire) for use with frequency inverter, OPEN drive speed at 87 Hz, see.6 and.7 The operating current in door drives can reach up to x the rated current for limited periods, see.7 and.8 5 When using a temperature range of +0 C C use half of maximum movements per hour, see also. 6 Maximum possible revolutions of output-shaft with integrated limit switch, see.9.0 Subject to alterations. (_Cf)
5 . Notes. European directive In accordance with the product standard EN - Doors- and EN 5 Safety in use of power operated doors-requirements.. Movements per hour The indicated movements per hour (See item -. Technical data) may not be exeeded.. Magnetic brake The optional magnetic brake locks the output-shaft when the motor is switched off. The magnetic brake ensures precise positioning of the door in the limit position and avoids overrunning the limit position of the door. Slight heating ensures trouble-free operation at low outside temperatures.. Gear self-braking / Brake Drives without an electric brake have a self-sustaining worm gear and stop automatically. On drives with an electric brake, stopping is achieved by the external brake. Brake inspection must always be carried out by qualified service engineers..5 Manual operation In the event of power failure, the door can be opened by hand after releasing the friction clutch. Emergency manual operation by crank handle or chain is also available as an option (e.g. for top-hung sliding doors)..6 Output torque / Door weight / Friction clutch.7 Motor overload protection Motor overload protection must be able to withstand x the operating motor current because the starting current of the drive unit can reach these levels for short periods..8 Use with external frequency inverter For external frequency inverters applies: A higher than recommended drive speed puts extra load onto the gear. This extra load must be taken into account when sizing a drive by reducing the available output torque.. The admissible drive speeds may not be exceeded (See item -. Technical data). The operating forces must comply with EN 5, and the corresponding EMC directives must likewise be observed. If selecting a frequency inverter, note that the starting current of the drive unit can reach x of the operating motor current..9 Integrated limit switch The door construction should be designed to prevent the disengaging of drive elements (sprocket, chain, rack etc.). The stopping accuracy of the ST with magnetic brake and a limit switch range of E0 is approximately +/- 5mm (for E0, approx. +/- 5mm). The door construction must be designed to compensate onsite these differences (e.g. height- of the rubber profile of the safety edge). For higher requirements regarding stopping accuracy, we recommend the use of separate limit switches (roller-arm limit switches, inductive limit switches, etc.). The integrated slipping clutch guarantees impact-damped, lowwear operation. The admissible output torque is pre-adjusted. If the clutch is subject to higher forces than the admissible (e.g. the possibility of attempted forced entry) additional improvements of the door design may be required to prevent undesired opening of the door. The weights indicated apply to horizontal, rail-mounted sliding doors.. Dimensions. ST 9.5 ST 9. SG50R Worm gear with friction clutch Motor Terminal box / optional: integrated limit switch Magnetic brake 5 Hand wheel for slipping clutch adjustment 6 Output-shaft right (optional: left) 7 Optional: WS 905 control panel 8 Cover 6 Permitted installation: horizontal (as shown) or vertical (motor to the top) Subject to alterations. (_Cf).0
6 . ST 6.5 ST Worm gear with friction clutch Motor Terminal box / optional: integrated limit switch Magnetic brake 5 Hand wheel for friction clutch adjustment 6 Output-shaft right (optional: left) 7 Optional: WS 905 control panel 8 Cover ST 6.5 ST 6. ST 0.5 ST 0. L Permitted installation: horizontal (as shown) or vertical (motor to the top). ST 60.5 ST 80. SG5R Worm gear with friction clutch Motor Terminal box / optional: integrated limit switch Magnetic brake 5 Friction clutch adjustment (SW 7) 6 Output-shaft right (optional: left) 7 Optional: WS 905 control panel 8 Cover ST 60.5 ST 60. ST 80.5 ST 80. L Permitted installation: horizontal (as shown) or vertical (motor to the top). Emergency manual operation optional Hand crank operation NHK Rapid hand chain operator SK ( SG50) Hand chain operator KNH ( SG85 / SG5) Read note in.5.0 Subject to alterations. (_Cf) For Series Part no. L H SG50 SG85 SG
7 5. Attachments / Accessories 5. Mounting base ST 9.5 ST Housing ST 9.5 ST 0. ST ST 9.5 / 9. Part no. 000 Right- or left-hand use Housing Part no Right- or left-hand use Locking cpl. for housing Part no units 5. Sprockets / chain Chain (p x b) Description Part no. B- (/ x 7/6 ) 6 B- ( x 7,0mm),0m 5,0m Link,5m 5,0m Link Sprockets for Designation Teeth s Part no. D K D 0 D n D i B H ST 9.5 / ST 9. ST 6.5 ST 0. ST 60.5 ST 80. B- (/ x 7/6 ) 0000,9 90 5, 0 6 B- ( x 7,0mm) , , 5 6 B- ( x 7,0mm) , , 5 5. C-profile For For Chain Part no. A B C S ST 9.5 / ST 9. ST 6.5 ST 80. B- (/ x 7/6 ) 007 9,5 6 B- ( x 7,0mm) ,5 5.5 Chain-tensioner For For Chain Part no. L ST 9.5 / ST 9. ST 6.5 ST 80. B- (/ x 7/6 ) B- ( x 7,0mm) Subject to alterations. (_Cf).05
8
9 Door controls for ST WS 905 TS 00 WS 905 Reversing contactor control WS 905 Technical data Suitable for ST with NES mechanical limit switch Supply voltage: N~0V, PE ~0V, PE N~00V, PE Control voltage: V AC reversing contactors Permissible temperature range: C Housing Dimensions W x H x D [mm]: 5 x 0 x 09 Protection class: IP5 Design Mechanically locked reversing contactors Positioning button CLOSE / OPEN Plug-in connection cable to for configuration with integrated mechanical limit switch NES Available with optional readywired CEE plug, regarded as mains circuit breaker under the terms of EN 5. Functions Operating mode: Hold to run CLOSE / OPEN via an external control device TS 00 TS 00 Automatic door control Technical data Suitable for ST with DES digital limit switch or NES mechanical limit switch Supply voltage: N~0V, PE / ~0V, PE / N~00V, PE Control voltage: V DC Mains supply ratings for external devices: V DC (0.5A) / 0V AC (A) integrated reversing contactors (up to kw motor power) Display for programming ( lines with 0 signs) Permissible temperature range: C Housing Synthetic housing with transparent cover, Dimensions W x H x D [mm]: 0 x 00 x 85 Protection class: IP55 Design Plugged terminals with screw connections Pluggable cable sets to the with DES or NES Integrated push buttons for the adjustment of the door positions in use with DES Connectors for control devices ( for the door area, for gatekeeper operation) Functions Automatic detection of DES or NES limit switches Intermediate open position for passengers (for use with NES is an additional limit switch required) Convinient adjustment via selector switch and display status Adjustment of the door final positions and intermediate positions from the operator level (DES) Self-hold in both directions, in case of failure - automatic switching to Hold to run mode Safety edge system 8k, evaluation for 6 safety edges Connection plugs for control devices with next function (pull switch or external radio receiver) Integrated timer with week program, OFF via external switch Automatical run-time monitoring (real runtime + 8%) Automatic closing feature adjustable (-999 sekc.), adjustable in steps of seconds Possibility of adjustable clearance time (-99 Sek.) Separated adjustment of the automatic closing function for complete- or partially opening Adjustable function of the traffic lights in the final door positions or the clearance time Adjustable reaction of the photo cell in the final limit position OPEN Fault memory Cycle counter (non-resettable) and maintenance cycle counter Modul with Relays for the final door positions and faults (potential free) Subject to alterations. (_Dc).0
10 Connection options TS 00 Slot for inductive signal transmission (ASO) Slot for -channel radio 6 safety edges 8 K x x x V / 0.5 A External Potential-free signal contacts Slot for loop detector N~0 V, PE ~0 V, PE N~00 V, PE 0 V /.0 A External Door controls and accessories Designation Description Part no. WS Reversing contactors V For drives without limit switch; with 0.8m cable and connection plugs for, without CEE-plug WS Reversing contactors V For drives with limit switch; with 0.8m cable and connection plugs for, without CEE-plug TS 00 ST-door control for DES/NES DES connection cable for TS 00 NES connection cable for TS 00 Inductive signal transmission (ASO) 5 Connection to drives with digital limit switch, pluggable on both sides; length of cable:.0m Connection to drives with mechanical limit switch, pluggable on both sides; length of cable:.0m Modul for TS 00 for monitoring of inductive signals from safety edges (brand ASO) Radio receiver -channel Loop detector -channel 6 7 Modul for TS 00 (for Opening and Intermediate opening) Modul for TS 00 (for OPEN- and CLOSE signal) Subject to alterations. (_Dc)
ELEKTROMATEN SI Rapid Safedrive. Emergency manual operation. Door controls. Limit switches. Mounting. Special versions. Series SG63F SI 17.
SI Rapid Safedrive For driving: High-speed sectional doors and high-speed rolling doors which require an anti-fallback device Series SG6F SI 7. Series SI 5. - SI 0. SI 0.70 - SI 8.6 Series SG5F SI 60.
More informationELEKTROMATEN SE Sectional-door-drive. Emergency manual operation. Special versions. Limit switches. Door controls. Mounting
SE Sectional-door-drive For driving: Counterbalanced sectional doors Series KG0 SE. / SE. WS Series / E SE 9. -. SE. DU SE.80 FI / SE.80 FI SE are special drives for counterbalanced sectional doors. The
More informationELEKTROMATEN SI FI Safedrive with built-on frequency inverter
SI FI Safedrive with built-on frequency inverter For driving: High-speed sectional doors and high-speed rolling doors which require an anti-fallback device Series SGF SI,.0 FI - SI.0 FI Series SG8F SI
More informationOpener with external control unit Opener with integrated control unit (Illustration: Deadman mode)
Informations Door system Opener with external control unit 1 8 2 7 6 5 6 7 4 Opener with integrated control unit (Illustration: Deadman mode) 1 2 4 Opener with external control unit 1 Opener 2 Control
More informationMechanical Operating Instructions
Mechanical Operating Instructions SE 5.24 WS / SE 5.24 51172095 / 04.2006 Bau muster Zertifizierung geprüft EN 13241-1 OPERATING INSTRUCTIONS 52210111 consisting of: M : Mechanical Operating Instructions
More informationDoor Control Panel TS 960. instructions. (Design and functions subject to change) /
Electrical operating Operating instructions Door Control Panel TS 960 GB (Design and functions subject to change) 51171098 / 10.2002 OPERATING INSTRUCTIONS PAGE SAFETY DIRECTIONS...4 FUNCTION OVERVIEW...6
More informationOperating Instructions for Roll-Up Door Operators / MDF
Operating Instructions for Roll-Up Door Operators / MDF GB Roll-Up Door Operator / MDF / Rev. 0.0 1 1. Contents 3. General safety instructions 1. Contents 2 2. Key to symbols 2 3. General safety instructions
More informationRolling door drives and controls robust and safe
Rolling door drives and controls robust and safe A lot of advantages The robust elero door drives are available in different versions. Combined with equal controls they offer a solution for almost every
More informationInstallation instructions
Installation instructions Door control TS 971 Automatic control panel with radio Version: 51171521 -en- Version: f / 07.2015 0000000 0000 51171521 XXXXX GfA ELEKTROMATEN GmbH & Co. KG Wiesenstraße 81 40549
More informationElectrical operating instructions
en Electrical operating instructions Door control panel TS 958 Software 1.0 - (Design and functions subject to change) 51171324 - c 03.2007 OPERATING INSTRUCTIONS Page SAFETY DIRECTIONS...4 INSTALLATION
More informationSYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN
SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT
More informationInstallation Instructions
Installation Instructions ELEKTROMAT SE 15.48-25,40 NOT DEFINED Model: 10004112 10006 -en- Status: 21.07.2016 2 GfA ELEKTROMATEN UK Ltd Titan Business Centre Spartan Close Warwick CV34 6RR United Kingdom
More informationSYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN
SYMBOL LEGEND DANGER THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN WARNING THIS WARNS THAT MATERIALS MAY BE DAMAGED IF APPROPRIATE PRECAUTIONS ARE NOT
More informationLexium integrated drives
Description ILp for DeviceNet, EtherCAT, Modbus TCP, ILE with brushless DC motor Description ILE comprise control electronics with a fieldbus interface for DeviceNet, EtherCAT, Modbus TCP or and a brushless
More informationInstallation instructions
en Installation instructions Door control TS 970 51171582_c_01.2014 0000000 0000 51171582 XXXXX 2 GfA - Gesellschaft für Antriebstechnik GmbH Wiesenstraße 81 D-40549 Düsseldorf, Germany www.gfa-elektromaten.de
More informationElectrical operating instructions
en Electrical operating instructions Door control panel TS 961 Software 2.6 (Design and functions subject to change) 51171292 - f 02.2013 OPERATING INSTRUCTIONS Page SAFETY DIRECTIONS...4 INSTALLATION
More informationLexium integrated drives
Description ILp for CANopen, PROFIBUS DP, RS ILE with brushless DC motor Description ILE comprise control electronics with a fieldbus interface for CANopen DS, PROFIBUS DP or RS and a brushless DC motor.
More informationMechanical operating instructions
en Mechanical operating instructions Safedrive - ELEKTROMATEN SI / SIK 51172028 - i 09.2011 OPERATING INSTRUCTIONS 52210113 consisting of: M : Mechanical operating instructions E : Electrical operating
More informationCI-tronic Soft Start Motor Controller Type MCI 25B with Brake
Data sheet CI-tronic Soft Start Motor Controller Type MCI 25B with Brake MCI 25B motor controller with brake is designed for soft starting and braking of 3 phase AC motors. The digital controlled soft
More informationElectrical operating instructions
en Electrical operating instructions Reversing contactor universal 2 Contactor / 24V for three- and single- phase motor 51171134 - d 04.2009 OPERATING INSTRUCTIONS 52210115 consisting of: E : Electrical
More informationHITACHI ELECTRIC CHAIN HOISTS
HITACHI ELECTRIC CHAIN HOISTS Hitachi s reputation for excellence in design, quality, reliability and performance has made this brand a global market leader. With over three decades of proven reliability
More informationHIGH SPEED SLIDING GATE OPENER
HIGH SPEED SLIDING GATE OPENER Model: is1200 + Elsema s Eclipse Control Card with GDS Operator USER MANUAL CONTENTS Section No: Page No: 1 Safety Precautions 3 2 Wiring Requirements 4 3 Installation details
More informationACME SCREW LINEAR ACTUATOR. OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor
ACME SCREW LINEAR ACTUATOR ATL 10 AC motor Stroke OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor Rear bracket SP Pin Standard head with threaded hollow bore 80 BA depth 17 Stroke end reed switches FCM
More informationSlide gate openers MOVEMENT BRINGS MORE
Slide gate openers MOVEMENT BRINGS MORE Our standard. Responsible production. - 2 - Our tradition. Striving for perfection. 30 years of experience made ELKA one of the leading companies in the field of
More informationENGINE WINCHES from 300 to 5000 kg - TS and TD Series
ENGINE WINCHES from 300 to 5000 kg - TS and TD Series INSTRUCTION MANUAL START-UP AND MAINTENANCE In an endeavor to improve its products, HUCHEZ reserves the right to alter the equipment described herein,
More informationCompact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:
Compact Heat Meters Features Compact design Simple operation Pulsed output Measures heating or cooling Specification Product Codes Water Meter Temp. range 10 to 90 C Nominal pressure 16bar Installation
More informationOverload Relays. SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A for standard applications. 5/78 Siemens IC Overview
SIRIUS 3RU2 Thermal Overload Relays 3RU2 up to 40 A Overview 1 2 3 4 6 1 2 NSB0_0207a Connection for mounting onto contactors: Optimally adapted in electrical, mechanical and design terms to the contactors.
More informationIndex. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.
Index Index Page Manual Motor Starters 1 Auxiliary Contact Blocks 1 Trip Alarm Auxiliary 1 Switch Shunt Release 1 Under-voltage Release 2 Accessories 2 Busbar Connectors 2 Enclosures 2 Leistung, kw C mv
More informationREVISED ATM72 Auto Transfer Module
Capricorn Controls DA01ATM1-1 Data & Application Note Page 1 of 8 REVISED - - - ATM72 Auto Transfer Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom
More informationAE 9... AE 40 Contactors NE... Contactor Relays
Technical data AE 9... AE 0 Contactors NE... Contactor Relays AE 9... AE 0 Contactors NE.. Contactor Relays Contents AE 9... AE 0 Contactors Description... 2 Ordering Details... 3 Technical Data... Terminal
More informationZAP Controls. ZAP Controls. Series 3 Commercial Operator Catalog. Series 3 Commercial Operator Catalog. ZAP Series 3 Simply Logical.
Series 3 Commercial Operator Catalog Series 3 Commercial Operator Catalog 1 Table of Contents Product Commercial Operators 4 825-3 Medium Duty Sectional Door Operator 5 8825-3 Heavy Duty Sectional Door
More informationTransmission systems: Multiple components that have the same type of movement (rotational, linear, etc)
Transmission systems: Multiple components that have the same type of movement (rotational, linear, etc) Transformation systems: Different components in the system have different types of movement Ex: rotational
More information06/001. Overload Relays, Motor-Protective Relays Overview. Overload / Motor-Protective Relays. Moeller HPL /2002
Overload Relays, Motor-Protective Relays Overview 06/00 Overload relays, motor-protective relays Page Technical overview 06/00 System overview 05/006 Overload relays, motor-protective relays 06/004 ZE,
More informationInstallation instructions
aus Installation instructions Door Control TS 970 51171635 b 11.2013 0000000 0000 511711635 XXXXX 2 GfA-ELEKTROMATEN Australia Pty Ltd P.O. Box 267 Roseville 2069 NSW Telephone: 02 9882 2782 Facsimile:
More informationTechnical Data Sheets
GE Consumer & Industrial Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 160 200 250 300 kva PurePulse TM 400 Vac CE Series 1 Date of issue: 15.02.2007 SGSE160-200S1UPS01
More information! C A U T I O N! Damages on the machine possible.
1 The PIK is a connecting element between electro motor and hydraulik pump in combination with an oil - air cooler. General Hints Please read through these mounting instructions carefully before you assemble
More informationModifications List. Control and Panel Modifications. Call: Effective Nov. 1, 2012
Modifications List The following chart provides a list of modifications which are available. For more details about these modifications, please refer to the following pages. Note: If more than one modification
More informationDycon D2430 EN54-4 Fire Alarm Power Supply Series
Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product
More informationDKG-114 MANUAL AND REMOTE START UNIT
DKG-114 MANUAL AND REMOTE START UNIT FEATURES Both manual and remote controlled engine starting and stopping, Automatic shutdown on fault condition, Optional cooldown cycle on remote start operation, Optional
More informationSPEEDROLLER SERVICE MANUAL CE DECLARATIONS LOG BOOK USER MANUAL. Edition : May 2011
SERVICE MANUAL CE DECLARATIONS LOG BOOK USER MANUAL SPEEDROLLER Edition : May 2011 1 8 2 3 4 Main components 1 drive 2 wind roller with hood (optional) 3 door panel 4 aluminium hinge profile 5 window section
More informationInterroll. Product Description. Material Versions. Technical Data. Options. Order Information. Accessories. Standard Asynchronous
D rum Motor Product Description Material Versions Applications Characteristics The drum motor is perfect for high torque applications with limited space or access. Small feed conveyors with high-duty cycles
More informationElectrical Operating Instructions
Electrical Operating Instructions Door Control Panel TS 970 Software 4.5 - (Design and functions subject to change) 51171271 - i 01.2012 Northern Sales & Distribution Centre The Door Centre, Discovery
More informationCOOKSON OWNER'S MANUAL
COOKSON OWNER'S MANUAL FDO-A10 INDUSTRIAL DUTY FIRE DOOR OPERATOR R L I S T E D 3040233 US CONTROL PANEL SERIAL# OPERATOR SERIAL# 9001.DWG ECN 0959 REV 4 SPECIFICATIONS MOTOR TYPE:...INTERMITTENT HORSEPOWER:...1/8
More informationmono-mix Contents Complete Equipment with Scope of Supplies 3 Accessories 4-5 Spare Parts
mono-mix Contents Page Complete Equipment with Scope of Supplies 3 Accessories 4-5 Spare Parts mono-mix-fu 230V 1ph 6-9 Control panel FU 230V 1ph 10-13 Control panel FU 230V 1ph with water delay relay
More informationSMS PRODUCT CATALOGUE
SMS PRODUCT CATALOGUE CONTENTS 1 TAKEDO 3VF-NXP - LIFT INVERTER Page 3 2 TAKEDO 3VF-V20 - OPEN LOOP LIFT INVERTER Page 6 3 TAKEDO ENERGY - DYNAMIC BRAKING REGENERATIVE UNIT Page 7 4 HYDROVERT VVVF FOR
More information1. Basic parameters... 1
WS standard version CONTENT 1. Basic parameters... 1 2. Basic diameters... 2 2.1. WS PRIME, WS ECONOMIC machine with standard turntable... 2 2.2. WS PRACTIC machine with turntable with cut-out... 3 3.
More informationAssembly and Operating Instructions
A35AE FU...A150AE FU en Assembly and Operating Instructions Plug-in drives Important information for: Fitters / Electricians / Users Please forward accordingly! These instructions must be kept safe for
More informationLIFTMASTER MAGIC BUTTON FS10 & LPK5 FAST SLIDER
R MAGIC BUTTON FS0 & LPK5 FAST SLIDER OPERATORS MANUAL FEATURES High speed -800mm/second Corrosion resistant - Hot dip galvanised base with stainless steel cover Speed flexibility - Slow start / slow stop
More informationBETA Switching Switches and Light Indicators
Siemens AG 2008 BETA Switching /2 Product overview /3 5TE8 control switches / 5TE4 pushbuttons /2 5TE5 light indicators /5 5TE8 ON/OFF switches /22 5TE9 busbars /24 5TE switch disconnectors Siemens ET
More informationCommercial Garage Door & Gate Operators
Commercial Garage Door & Gate Operators Approved to UL Standard 325 Industrial Electronic Door Control LYNX 6000 2 1. Electronic Control Provides unmatched ruggedness that incorporates the newest features
More informationElectrical Operating Instructions
Electrical Operating Instructions Door Control Panel TS 958 Software 1.2 - (Design and functions subject to change) 51171324 - f 01.2010 Northern Sales & Distribution Centre The Door Centre, Discovery
More information3RT14 Contactors with 3 Main Contacts
3RT14 Contactors with 3 Main Contacts for Switching Resistive Loads Contactor Size 3RT14 46 Mechanical endurance Oper. 10 million Electrical endurance Oper. 0.5 million C-1 utilization category at I e
More informationTAE pole Contactors
TAE9...26 3-pole Contactors d.c. operated with double-winding coil SB8033C3 Utilisation TAE9 to TAE26 contactors are a compliment to the DC control contactor range. The coils have large voltage ranges
More informationSD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,
4 Electrics for Rolling Stock Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches, Change-Over-Switches 600 V to 3 kv Catalogue F84.en
More informationTechnical Data Sheets
GE Digital Energy Power Quality Technical Data Sheets Digital Energy Uninterruptible Power Supply SG-CE Series 60 80 100 120 kva PurePulse 400 Vac CE Series 1 SG-CE Series 100-120 kva PurePulse SG-CE Series
More informationTechnical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter
Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control
More informationPSM72H Push-Button Start Module
Capricorn Controls DA02PSM72H1-2 Data & Application Note Page 1 of 6 PSM72H Push-Button Start Module Genset Controls - Timers/Monitors/Trips - Battery Charging Spares & Accessories - Custom Products Ultra
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE704 AUTOSTART CONTROL MODULE OPERATING MANUAL 057-042 704 Operating Instructions Issue 2.1 18/06/2007 11:27:00 JR - 1 - Deep Sea Electronics Plc
More informationLocking Assemblies & Locking Elements
US 01 2016 Locking Assemblies & Locking Elements Partner for Performance www.ringfeder.com Welcome to your system supplier for every aspect of power transmission Today s RINGFEDER POWER TRANSMISSION GMBH
More informationBALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. MASS [Kg] STROKE T STROKE LENGTH STROKE LENGTH. standard brake CODE
BALL SCREW LINEAR ACTUATOR OVERALL DIMENSIONS BSA 10 AC motor Stroke La =Lc + Stroke Lc Capacitor T Rear bracket SP Pin Standard head with threaded hollow bore BA 80 depth 17 Stroke end reed switches FCM
More informationInterroll. Material Versions. Product Description. Technical Data. Options. Accessories. Order Information. Standard Asynchronous
Product Description Material Versions Applications Characteristics This drum motor has been developed especially for applications requiring a strong drive. Small conveyors with high-duty cycles Airport
More informationMax. stand-by power without accessories Use frequency 100% Max leaf width Motor Motor powered at 36V with encoder Max.
Automated system for NEW Passage opening 700-3.000 mm Max. leaf weight 110-2x70 Kg FAAC SERIES automated systems are intended for the automation of exits in compliance with European Standard EN16005; in
More informationElectrical operating instructions
en Electrical operating instructions Door control panel TS 981 FT Software 2.1 - (Design and functions subject to change) 51171393 - f 06.2014 OPERATING INSTRUCTIONS Page SAFETY DIRECTIONS...4 INSTALLATION
More informationThe electro-mechanical power steering with dual pinion
Service Training Self-study programme 317 The electro-mechanical power steering with dual pinion Design and function The electro-mechanical power steering has many advantages over the hydraulic steering
More informationTHREE PHASE AND SINGLE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATION AND MAINTENANCE BOOKLET Rev
MORATTO S.R.L. Electrical Machinery I 31030 PERO DI BREDA (Treviso) Italy Via A Volta, 2 Tel. +390422904032 fax +39042290363 www. moratto.it - moratto@moratto.it THREE PHASE AND SINGLE PHASE ASYNCHRONOUS
More informationSafety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries
Safety Relay Unit Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries Two-pole slim models that are only 22.5 mm wide, three-pole models that are only 68 mm wide,
More informationC-SERIES S-SERIES. Metric Machine Screw Jacks EMA LINEAR ACTUATORS
C-SERIES S-SERIES Metric Machine Screw Jacks EMA LINEAR ACTUATORS Power Jacks has a proud engineering heritage dating from the earliest years of the 20th Century. A heritage that is about excellence: about
More informationWEEK DELIVERY. High-Speed Doors. For optimised material flow and improved efficiency. Made in Germany
WEEK DELIVERY High-Speed Doors For optimised material flow and improved efficiency Made in Germany Hörmann Advantages Quality features of the flexible high-speed doors 1 Safety as standard SAFETY LIGHT
More informationDEVICE STATE/BYPASSED FAILURE OVERLOAD
Technical specifications Type 5. 7. Control electronics Rated values Terminal Rated control supply voltage A1A2 V AC 115 230 115 230 Tolerance % -15+10-15+10 Rated control supply STANDBY ma 15 15 Rated
More informationTeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series
Selection 3-pole shockproof contactors FG d.c. supply Selection guide for utilisation categories DC-1 to DC-5 Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current
More informationProduct Information ECN 425 EQN 437. Absolute Rotary Encoders with Hollow Shaft and Expanding Ring Coupling for Safety-Related Applications
Product Information ECN 425 EQN 437 Absolute Rotary Encoders with Hollow Shaft and Expanding Ring Coupling for Safety-Related Applications 4/2014 ECN 425, EQN 437 Rotary encoders for absolute position
More informationElectrical operating instructions
en Electrical operating instructions Door control panel TS 981 Software 2.6 (Design and functions subject to change) 0000000 0000 51171314 XXXXX 51171314 - q 07.2015 OPERATING INSTRUCTIONS Page SAFETY
More informationHP High-Performance Gear Units with <2' Adjustable Backlash
Page HP High-Performance Gear Units with
More informationINTERROLL DRUM MOTOR 80i
Product Description Material Versions Applications Characteristics The drum motor is perfect for high torque applications with limited space or access. Small feed conveyors with high-duty cycles Packaging
More informationPower Electronics. Motor brake relay GA 9031 ministop
Power Electronics Motor brake relay GA 90 ministop 0 Thyristor electronic brake relay for motors up to kw Adjustable braking current up to 0 A Adjustable braking time Automatic standstill monitoring (optional)
More informationTechnical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis
Preliminary Datasheet Technical Datasheet Compact DC Energy Meter RISH EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control
More informationPage. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases
Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar
More information702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS
702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS > TABLE OF CONTENTS 1 DESCRIPTION OF OPERATION... 4 1.1 MANUAL MODE OPERATION... 4 1.2 AUTOMATIC MODE OF OPERATION...
More informationControls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)
Controls THERMAL OVERLOAD RELAYS RW..D (up to 0A) 0800 7 9 Thermal Overload Relays RW..D (up to 0A) THERMAL OVERLOAD RELAYS RW..D (up to 0A) Summary Introduction RW7-D Thermal Overload Relay from 0.8 up
More informationzelsius Installation and operating manual All that counts EnergyMetering
EnergyMetering zelsius Installation and operating manual Electronic compact heat meter M-Bus and 2 inputs/outputs optional Coaxial measuring capsule 2" q p 0.6/1.5/2.5 m³/h All that counts General information
More informationDC-PMM/24V Power Management Modul für Positionier-Motor POSMO A Power Management Module for Positioning Motor POSMO A
s DC-PMM/24V Power Management Modul für Positionier-Motor POSMO A Power Management Module for Positioning Motor POSMO A Best. Nr. / Order No.: 9AL2137-1AA00-1AA0 Betriebsanleitung Operating Instructions
More informationTITANO 400V SLIDING GATE OPENER
TITANO 400V SLIDING GATE OPENER USE AND MAINTENANCE MANUAL V07 /2018 TECHNICAL FEATURES א א א א QK-T3000 QK-T4000 QK-T6000 (VAC) 400 Three Phase א א א א (W) 700 750 1500 א א א א (A) 1,7 2,2 3,7 א א C -30/+70
More informationDC motors. G-motion. CTi Automation - Phone: Fax: Web:
G-motion No matter which drive solution you imagine, we make your dreams come true. True to our slogan (one stop shopping) we offer you a complete programme of electronic and mechanical drive systems which
More informationGate & Door Controller with LCD and Intelligent Technology
2nd Edition Gate & Door Controller with LCD and Intelligent Technology 24Sv1 and 12Sv1 Motor Controllers Setup and Technical information for single motor controller for gates & doors Includes latest Intelligent
More informationRotary-Linear Actuator HSE4 Hydraulic / 100 Bar
Rotary-Linear Actuator HSE4 Hydraulic / 100 Bar 4 Function and features K A1 G1 B1 G2 KM Y B2 RE A2 Z S2 A S1 W B KS [ Operation ] [ Operating pressure ] The Eckart rotary-linear actuator HSE4 is a combination
More informationRotary Indexing Tables are used in rotary special purpose machines and other types of machines to mount fixtures, work pieces for precision indexing.
GMT Rotary Indexing Tables are used in rotary special purpose machines and other types of machines to mount fixtures, work pieces for precision indexing. The GMT Rotary Indexing Tables are fitted with
More informationAlpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter
Alpha EM DC Technical Datasheet Compact DC Energy Meter ALPHA EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor and control the target
More informationDatasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.
Datasheet Compact Heat Meters Technical Overview Heat energy is calculated by using a matched pair of high accuracy sensors to measure the difference between the forward and flow temperatures. The amount
More informationWELDING POSITIONER S OPERATION MANUAL CWP40
WELDING POSITIONER S OPERATION MANUAL CWP40 Revision May 19 2015 Note: The information contained in this manual is intended to be accurate. However the manufacturer retain the rights to make changes in
More informationHigh performances 5 Axis Machining Center Performance Technology Power Accuracy
High performances 5 Axis Machining Center Performance Technology Power Accuracy Powerfull, Rapid, Accurate 5 Axes High Performance Machining Center The MX multifunction machining center offers high levels
More informationMounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)
Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator) Linear Actuator with Type 3260 Control Valve Rotary actuator with lever system Linear actuator with Type 3321 (V2001) Control
More informationModel ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG iss 9 1
Model ER-340XRi / ER-680XRi / ER-1220XRi DC drive product manual HG102909 iss 9 1 This drive is an isolated 4 Quadrant speed controller for shunt wound or permanent magnet motors. It utilises speed feedback
More informationModel 340i / 680i / 1220i DC drive product manual HG iss 8 1
Model 340i / 680i / 1220i DC drive product manual HG102938 iss 8 1 Sprint Electric Limited, Arundel, UK Tel. +44 (0)1903 730000 Fax. +44 (0)1903 730893 Email. info@sprint-electric.com www.sprint-electric.com
More informationCompact Units. For fluid grease, NLGI grades 000, 00 Group MKF 0.1 or 0.2 l/min EN
1-16-EN Compact Units For fluid grease, NLGI grades, Group MKF.1 or.2 l/min MKF1-KW2-2 MKF2-KW3-2 MKF2-KW6-22 These MKFcompact units were developed to supply intermittently operated single-line centralized
More informationElectronic Circuit Breaker ESS20
Electronic Circuit Breaker ESS20 Description Electronic circuit breaker type ESS20 is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 24 V switch-mode
More informationINSTRUCTION & INSTALLATION
INSTRUCTION & INSTALLATION MANUAL MODELS: CCL-eHOME T1C16 CCL-eHOME T1C32 CCL-eHOME T2C16 CCL-eHOME T2C32 WALLBOX ehome SERIES WALLBOX ehome Instruction and Installation manual This document is copyrighted,
More informationMODEL JH JACKSHAFT INDUSTRIAL DOOR OPERATOR INSTALLATION MANUAL. OPERATOR SPECIALTY COMPANY, INC. P.O. Box 128 Casnovia, MI 49318
MODEL JH JACKSHAFT INDUSTRIAL DOOR OPERATOR INSTALLATION MANUAL OPERATOR SPECIALTY COMPANY, INC. P.O. Box 128 Casnovia, MI 49318 OSCO requires the use of a reversing edge or photoelectric control for pedestrian
More informationLow-Voltage Motors N-compact Standardline Operation on supply system
Low-Voltage Motors N-compact Standardline Operation on supply system 2 2/2 Overview 2/2 Benefits 2/2 Technical specifications 2/2 Selection and Ordering Data 2/ Options 2/ Dimensional drawings 2/4 More
More informationVigilec doble. Pump controlller and protection for two (3ph/1ph) pumps INSTALLATION AND OPERATION
V2P/V2T Vigilec doble INSTALLATION AND OPERATION V2P V2T Pump controlller and protection for two (3ph/1ph) pumps (V2P: control by pressure switches/ V2T: control by pressure transducer) General Description
More informationEM DC Multi-Function DC Energy Meter
Analogue Meters With Moving - Iron Movement EM DC Compact DC Energy Meter Ziegler EM DC series is specially designed to measure, display and communicate DC Voltage, Current, Power and Energy to monitor
More information