1 Installation Instructions LPK-OH - LEGACY/PHOENIX NG to LP Gas Conversion Kit Models: LEGACY42-IFT PHOENIX42-IFT WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable code and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer s instructions supplied with the kit. CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during installation. Sheet metal edges are sharp. Note: An arrow ( ) found in the text signifies change in content. 1 Components LPK-OH Description Dexen Valve Regulator Replacement Kit. Includes gas regulator, conversion label and instructions Main Burner Orifice (LP) Pilot orifice (.014 for LP) Installation instructions Installer conversion label Table 1.1 Note: The LPK-OH kit is for a one time conversion only. Discard unused parts. Note: For gas models not listed, refer to the model s installation instructions for proper conversion kit or contact your Hearth & Home Technologies dealer. For the dealer nearest you, please visit 1
2 2 Orifice Sizes for Conversions A. Conversion - Orifices LPK-OH (CONVERT TO LP) Threaded Orifice Size Model Table LEGACY42-IFT PHOENIX42-IFT 3 Preparation Required Tools 7/16 in. Open End Wrench (2) 3/4 in. Open End Wrench Safety Glasses Manometer #20 Tamper Proof Torx Small Cabinet Screwdriver Non-corrosive Leak-Check Solution A. Turn off the Gas and Electrical Power To turn off the gas, locate the manual shutoff valve in the control area in the bottom of the appliance. Turn the manual shutoff valve so it is perpendicular to the gas line (Figure 3.1). Shut off all electrical power to the appliance by turning off the appropriate circuit breaker or removing the fuse in the electrical panel. B. Access the Control Area Note: Care must be taken when working on appliance to avoid damage to logs, burner and hearth pieces. Remove the logs and grate, set aside. Remove (3) Front Hearth Refractory pieces. See Figure 3.2. OFF Front Hearth Refractory Grate Assembly Figure 3.1 Manual Shutoff Valve Figure 3.2 2
3 Remove (2) Side Hearth Refractory pieces. See Figure 3.3. Side Hearth Refractories Disconnect incoming flexible gas line from gas valve. Remove orange and green wires from the valve. Slide Burner Assembly towards the front of the appliance and stand upright. Make certain Burner Assembly is stable and will not fall over. Caution: Use care not to damage Burner Top or Refractory when standing Burner Assembly upright. When Burner Assembly is standing upright, access to components for conversion is possible. See Figure 3.6. Orifice Figure 3.3 Remove left and right Side Hearth Refractory Brackets, (3) screws each. See Figure 3.4. Valve Pilot Figure 3.6 Go to Section 4 - Converting the Appliance. Hearth Refractory Bracket Figure 3.4 Remove (4) screws, (2) per side, securing Burner Assembly to the base of the appliance. See Figure 3.5. Figure 3.5 3
4 4 Converting the Appliance The LEGACY42-IFT/PHOENIX42-IFT come equipped with a Dexen PIP valve.(figure 4.1) use only the Dexen Valve Regulator Replacement Kit or Replacement Valve. Follow the regulator replacement instructions that came with the regulator replacement kit. After completion of the regulator replacement instructions, return to these instructions. Note: Save the label that came with the Dexen conversion kit for later placement. Note: Remove all components blocking your access and set aside. Figure 4.1 Dexen Intermittent Pilot Valve 4
5 5 Replace the Pilot and Burner Orifice WARNING Fire Risk Orifices must be replaced Failure to replace the orifices could result in overheating the gas appliance and possibly damaging your appliance and your home. Note: Appearance of pilot may vary. PILOT ORIFICE PILOT HOOD A. Replace Pilot Orifice Loosen the nut at the base of the pilot hood with a 7/16 in. wrench. See Figures 5.1 & 5.2. Turn the nut until it comes free of the pilot. Discard the pilot orifice and replace it with the new LP pilot orifice. Handle carefully. Do not drop. Tighten the nut with a 7/16 in. wrench. Tighten until snug. (Used in assembly with 2-sided hood). PILOT TUBE ASSEMBLY CHECK FOR LEAKS Figure 5.2 Pilot Figure 5.1 Pilot Location 5
6 B. Replace Burner Orifice(s) Note: Test fittings for leaks with the pilot lit and the burner off. Burner Orifices - Novus NDV & NBV Using (2) 3/4 in. wrenches, disconnect flexible gas line from threaded orifice. See Figure 5.3. Using 3/4 in. wrench remove NG orifice from burner neck and discard orifice. See Figure 5.3. Replace the existing orifice with the appropriate propane orifice and tighten. Remove the NG air shutter. When converting from NG to propane, the air shutter must be removed. See Figure 5.4. Reconnect the flexible gas line to the new propane threaded orifice and tighten. All connections must be tightened and checked for leaks with a commercially available, non-corrosive leak check solution. Be sure to rinse off the solution when done leak testing. Natural Gas Figure 5.4 Air Shutter (Before & After) Propane Burner Neck Flexible Gas LIne Orifice Figure 5.3 Burner Orifice 6
7 6 Adjust the Air Shutter The LEGACY IFT/PHOENIX42-IFT require the air shutter be removed when the appliance is converted to burn propane. No futher air shutter adjustments need to be made. 7
8 7. A. Leak Test Checking Your Conversion WARNING Fire Risk Explosion Risk All connections must be checked and leaks must eliminated. Incomplete gas line connections could cause a gas leak. Turn on the gas and electricity. Gas Leak Test All connections must be tightened and checked for leaks with a commercially available, non-corrosive leak check solution. Be sure to rinse off the solution when done leak testing. If the solution indicates there is a leak, tighten and seal the connection and then retest. Leak Test Dexen Intermittent Pilot Ignition Models Turn on the appliance and test for leaks at the valve and the burner orifice using the method above. Inlet Gas Pressure Verify the inlet gas supply pressure by connecting a manometer to the inlet side of the valve. If the inlet gas pressure is incorrect, do not adjust without specific approval and instruction from the gas supplier. Changing inlet pressure may effect other appliances in the residence. Manifold Gas Pressure To measure the manifold pressure, loosen the manifold pressure tap with a small flathead screwdriver, and connect a manometer to the 1/8 in. manifold pressure tap on the side of the valve. See Figure 7.1. Ignite the appliance and ensure the pressure is between in. for NG and in. for LP water column. Shut off Appliance Remove the manometer and tighten the manifold pressure tap. 1. Loosen the Tap marked "OUT" with a small Screwdriver. B. Checking the Pressure Dexen Valve WARNING Fire Risk! Explosion Risk! Asphyxiation Risk! Manometer 2. Attach manometer hose. 3. Light main burner and check pressure. High pressure will damage valve. Low pressure could cause explosion. Check all fittings and connections with a noncorrosive commercially available leak-check solution. DO NOT use open flame. Figure 7.1 Intermittent Pilot Manometer Adjustment 8
9 8 All labels must be filled out and/or installed by the individual completing the conversion. This must be finished or the conversion is not complete. See Figures Fill out the installer conversion label (Figure 8.1). After filling out the label, clean an area near the existing rating label and attach. Attach the valve manufacturer conversion labels as indicated in Figures 8.2 and 8.3 Locate the lighting instruction card and attach the red LP or blue NG label (included with this conversion kit) over the existing blue or red label. LPK-OH Attaching Labels Place conversion label here Figure 8.2 Dexen Conversion Label Placement THIS PLATE MUST BE AFFIXED AS CLOSE AS POSSIBLE TO THE EXISTING RATING PLATE. THE FOLLOWING MUST BE COMPLETED BY THE INDIVIDUAL CONVERTING THISAPPLIANCE: THIS APPLIANCE HAS BEEN CONVERTED TO FUEL, ORIFICE, MANIFOLD PRESSURE, AND INPUT, ON (date), WITH KIT # LPK-OH BY (name &address of organization making this conversion) WHOACCEPTS THE RESPONSIBILITY FOR THE CORRECTNESS OF THIS CONVERSION. Figure 8.1 Conversion Label A THIS CONTROL HAS BEEN CONVERTED TO LP Figure 8.3 Dexen Conversion Label THIS CONTROL HAS BEEN CONVERTED TO NG 9
GAS CONVERSION KIT INSTALLATION INSTRUCTIONS
GAS CONVERSION KIT INSTALLATION INSTRUCTIONS These instructions apply to the following gas conversion kits: 8261139 8261140 8261141 8261142 8261143 8261144 8261158 8261747 8261748 8261964 8261965 8263059
More informationINSTALLATION INSTRUCTIONS FOR PCDE-36VA CONVERSION KIT
INSTALLATION INSTRUCTIONS FOR PCDE-36VA CONVERSION KIT CONVERTING FROM NATURAL GAS TO PROPANE/LP GAS For Use When Converting Model (V)V36ENA Series This conversion kit must be installed by a qualified
More informationInstallation Instructions for. For Use When Converting Model (V)M42(B) Vented Decorative Fireplace. Fold Bi-Fold Door After Releasing
Installation Instructions for PCBM-42 conversion kit Converting from Natural Gas to Propane/LP Gas For Use When Converting Model (V)M42(B) Vented Decorative Fireplace This conversion kit must be installed
More informationCHALLENGER Propane to Natural Gas Instructions
Kit Part Number: CCRKIT02 Kit Includes: - Rating Label - (3) Natural Gas Orifices - T-15 Torx Wrench Recommended Tools: - Phillips-Head Screwdriver - Standard Adjustable Wrenches - Calibrated Combustion
More informationINSTALLATION INSTRUCTIONS FOR PCBM-36C CONVERSION KIT From Natural Gas to Propane/LP Gas
INSTALLATION INSTRUCTIONS FOR PCBM-36C CONVERSION KIT From Natural Gas to Propane/LP Gas For Use When Converting Models CB36N and VCB36N This conversion kit must be installed by a qualified service agency.
More informationGas Conversion Kits and Instructions
General and Warnings FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance. Do not touch any electrical switch; do not use any phone in your building. Leave the building immediately.
More information1080 CF Valve Replacement Instructions
Overview This kit includes the newer American Flame gas control valve designed specifically for the 1080 CF gas fireplace. If you have a 1080 CF fireplace, and you are uncertain as to whether this kit
More informationTC30 TRANQUILITY BURNER KIT INSTRUCTIONS
IMPORTANT: THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER These instructions are supplementary to the Installation and Operating Instructions supplied with the fi replace and should be kept together.
More informationDVM36/42 SERIES LOG SET/BURNER MODULES INSTALLATION INSTRUCTIONS
DVM36/42 SERIES LOG SET/BURNER MODULES INSTALLATION INSTRUCTIONS For Use With (V)TC36 Series, (V)VC36/42 Series, (V)KC36/42 Series or DVC Series Fireplaces This log set/burner module must be installed
More informationApplies to: Models F, B, FE, and BE with spark pilot
Form CP-F/B-GC (11/17) R8 Obsoletes Form CP-F/B-GC (Version A.2) Gas Conversion Kits and Instructions Applies to: Models F, B, FE, and BE with spark pilot NOTE: Units with standing (match - lit) pilots
More informationCAUTION WARNING WARNING PROFLAME 2 UPGRADE KIT RX RX 300 NG/LP. Installation & Maintenance Manual
& Maintenance Manual PROFLAME 2 UPGRADE KIT + RX 300 NG/LP Upgrade Kit NG/LP Proflame 2 (Basic to Full Load with Remote) THIS KIT IS FOR USE WITH THE FOLLOWING MODELS: RX200: B34DT-2-F : B34 TOP VENT,
More informationROBERT H. PETERSON CO. AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS. Model APK-17(M)(P)
ROBERT H. PETERSON CO. Owner s Manual AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS FEATURES: CONTROL OPERATED ON/OFF VARIABLE FLAME-HEIGHT
More informationLegacy Combustion Chamber Replacement Kit
H0324700- Replacement Kit Instructions WARNING FOR YOUR SAFETY - This product must be installed and serviced by authorized personnel, qualifi ed in pool/spa heater installation. Improper installation and/or
More informationQ35 Series Automatic Vent Damper System
Installation Sheets Manual 121 Energy Conservation and Miscellaneous Kits Section Q Technical Bulletin Q35 Issue Date 0999 Q35 Series Automatic Vent Damper System Figure 1: Q35 Automatic Vent Damper System
More informationInstallation Instructions
PART NUMBER: CPLPCONV007A00 60,000---130,000 BTU/HR 2TO5TONS SMALL PACKAGED PRODUCTS GAS HEATING/ELECTRIC COOLING UNITS HIGH ALTITUDE ONLY 2001---6000 FT PROPANE CONVERSION KIT Installation Instructions
More informationTable of Contents. Parts Overview 1-3. Tools Needed 4. Recommended Service Parts 4. Gas Fire-Up Check List 5. Troubleshooting Flow Chart 6-9
GreenSmart TM 2 Parts Overview & Troubleshooting 6/13/2014 Table of Contents Section Page Number(s) Parts Overview 1-3 Tools Needed 4 Recommended Service Parts 4 Gas Fire-Up Check List 5 Troubleshooting
More informationAUTOMATIC REMOTE CAPABLE SAFETY PILOT SYSTEM
OWNER S MANUAL AUTOMATIC REMOTE CAPABLE SAFETY PILOT SYSTEM PRE-ASSEMBLED READY FOR INSTALLATION FEATURES: NON-STANDING FLAME-SENSING PILOT MANUAL SWITCH ON/OFF OPTIONAL REMOTE CONTROL BATTERY OPERATION
More informationModels: AFVK-SP-SPLIT AFVK-SP-H/L-SPLIT AFVK-SP-MH/L-SPLIT INSTALLATION AND OPERATING INSTRUCTION
Electronic Safety Pilot System for Vented Gas Logs Models: AFVK-SP-SPLIT AFVK-SP-H/L-SPLIT AFVK-SP-MH/L-SPLIT IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT ATTEMPT TO INSTALL
More informationNATURAL GAS CONVERSION MANUAL For Model FSISLP
NATURAL GAS CONVERSION MANUAL For Model FSISLP FOR OUTDOOR USE ONLY 1 4 3 6 5 2 Part No. Qty Description 1 RCOZZ00341A 1 Main Burner Valve & Manifold Assembly with Valves (NG) 2 RPAZZ00002A 1 Thread Sealing
More informationTroubleshooting Guide
Troubleshooting Guide IntelliFire Plus Ignition System *For authorized gas technicians use only. 9/15/2011 Hearth & Home Technologies Page1 Guide Table of Contents Introduction. 3 Tools and Instruments...
More informationSIT Pilot Assembly Retrofit - # 308 (Replaces R. Shaw Pilot Asbly) (SKU # )
Check Condition of Shipment SIT Assembly Retrofit - # 308 Upon receipt of this kit, check the condition of the packaging. Damage to the package should be noted on the carrier's freight receipt. Any damage
More informationRobert H. Peterson Co.
RHP Robert H. Peterson Co. OWNER S MANUAL AUTOMATIC REMOTE CAPABLE SAFETY PILOT SYSTEM PRE-ASSEMBLED READY FOR INSTALLATION (Suitable for G4, G45, and PB series burners) (Sizes 12"- 24" for natural; 12"-
More informationAUTOMATIC REMOTE CAPABLE SAFETY PILOT SYSTEM
OWNER S MANUAL AUTOMATIC REMOTE CAPABLE SAFETY PILOT SYSTEM PRE-ASSEMBLED READY FOR INSTALLATION (Suitable for G4, G45, and PB series burners) (Sizes 12"- 24" for natural; 12"- 36" for propane gas) MODEL
More informationTroubleshooting Manual
Troubleshooting Manual NOTICE: DO NOT DISCARD THIS MANUAL Models: LEGACY42-IFT PHOENIX42-IFT 1 TABLE OF CONTENTS A. Normal Operation...3 B. Wiring Diagram...4 C. Troubleshooting IntelliFire Touch...5 D.
More informationH280-series Valve Overheat / Relocation Kit Instructions: Standard Oven. Instructions for Applying Kit #
H280-series Valve Overheat / Relocation Kit Instructions: Standard Oven Instructions for Applying Kit #4522559 This kit is for a Standard 36 oven only. For convection RC 36 oven, use Kit #4522368 Installation
More information5270 Edison Ave., Chino, CA (Tel) (Fax)
5270 Edison Ave., Chino, CA 91710 (Tel) 800-790-1299 (Fax) 909-718-1949 NOTICE Dear Customers: Thank you for choosing our barbeque grill and hope that you enjoy our product. Our gas valves and components
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS NATURAL GAS CONVERSION KIT Standard Altitude Only / 0 2000 FT (0 610m) Small Package Products / 40,000 130,000 Btu/hr NPNGCONV004C00 This kit is used on: Two Stage Models: PGR5
More informationTroubleshooting Electronic Ignition
Troubleshooting Electronic Ignition Bob Wise CVC Coaching This session is designed to provide a broad approach to troubleshooting electronic ignition systems. Various hearth electronic systems will be
More informationMODEL RVS304. REMOTE CONTROLLED SAFETY PILOT KIT Supplemental Installation Instructions for use with Natural Gas Log Sets
MODEL RVS304 REMOTE CONTROLLED SAFETY PILOT KIT Supplemental Installation Instructions for use with Natural Gas Log Sets NOTE: This kit is for both Natural Gas and LP Gas applications. For LP (Propane)
More informationInstallation Manual. English. French
Installation Manual For model N400 - a 4.5 cu. ft., 2-way or 3-way, refrigerator. For model N500 - a 5.5 cu. ft., 2-way or 3-way, refrigerator. For model N510 - a 5.5 cu. ft., 2-way or 3-way, refrigerator.
More informationPHOENIX42-IFT. Service Parts. Part number list on following page. 10/ True View
42 True View 1 2 3 4 5 6 13 10 11 12 7 7.1 7.2 7.3 8 9 Part number list on following page. 10/18 ITEM DESCRIPTION COMMENTS PART NUMBER 1 Cover Plate, Top SRV4095-138 2 Insulation, Box SRV4095-311 3 Flue
More informationSERVICE MANUAL Model: SF-INS30-BK - Instructions -
SERVICE MANUAL Model: SF-INS30-BK - Instructions - NOTICE! DO NOT discard any hardware while servicing. It must be reused. This manual will assist a qualified service technician in the replacement of parts.
More informationMODERUSTIC Battery Operated Remote Control Electronic Safety Pilot System IPI Intermittent Pilot Light For Fire Pits or Fireplaces
MODERUSTIC Battery Operated Remote Control Electronic Safety Pilot System IPI Intermittent Pilot Light For Fire Pits or Fireplaces Model: AFVK-SP-MH/L Remote flame height adjustment DC Motor Drive Hi,
More informationGAS FIRED BROILERS 36W36 235W36 43W36 243W36 136W36 C36 V136W36 C45
DESIGN C E R TI F I E D THE MONTAGUE CO. SERVICE & PARTS MANUAL GAS FIRED BROILERS 36W36 235W36 43W36 243W36 136W36 C36 V136W36 C45 NOTICE This manual is prepared for the use of Service Technicians and
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS PROPANE GAS CONVERSION KIT High Altitude Only / 2001 6000 FT (610 1829m) Small Package Products / 40,000 130,000 Btu/hr NPLPCONV014B00 This kit is used on: Two Stage Models: PGR5
More informationAUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM FOR NATURAL OR PROPANE GAS EPK-1 PILOT KITS
INSTALLATION & OWNER S MANUAL AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM FOR NATURAL OR PROPANE GAS Models: EPK-1(M)(P) FEATURES: INTERMITTENT PILOT IGNITION NON-STANDING FLAME-SENSING PILOT MANUAL
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS PROPANE GAS CONVERSION KIT High Altitude Only / 2001 6000 FT (610 1829m) Small Package Products / 40,000 130,000 Btu/hr NPLPCONV014C00 This kit is used on: Two Models: PGR5 (Two
More informationTroubleshooting Guide
Troubleshooting Guide *For Authorized Gas Technicians Use Only* 1 Table of Contents Introduction 3 Tools and Instruments 4 Intellifire Component Parts 5 Intellifire Basics 7 Problem: The Ignitor makes
More informationB21 Series BASOTROL Gas Valve
Installation Instructions B21 Issue Date September 19, 2017 Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing BASO Gas Products. Carefully
More information27" Natural Gas Conversion Manual
S o n o m a PLATINUM EDITION 27" Natural Gas Conversion Manual FOR OUTDOOR USE ONLY TM 1 2 3 4 8 7 5 9 6 Part No. Qty Description 1 44213827 1 Hose 27" - 3/8" Flare Both Ends for Side Burner (NG) 2 40275101
More informationOWNER S MANUAL: Model # JGSBSEAR Searing Burner Station
JACKSON GRILLS INC. #106-2480 Mt. Lehman Rd. Abbotsford, BC V4X 2N3 TEL: 1(888) 287-3333 FAX: 1(877) 855-5373 SUPPORT: support@jacksongrills.com WEB SITE: www.jacksongrills.com OWNER S MANUAL: Model #
More informationINSTALLATION INSTRUCTIONS NATURAL TO PROPANE CONVERSION KIT
INSTALLATION INSTRUCTIONS NATURAL TO PROPANE CONVERSION KIT NAHA0080LP or PART NO. 83388 NOTE: Read the entire instruction manual before starting the installation. SAFETY CONSIDERATIONS Installing and
More informationSafety Pilot System For Vented Gas Logs
HI A M E R I C A N F L A M E A F Models: AFVK AFVK-H/L AFVK-VH/L Safety Pilot System For Vented Gas Logs Manual Flame Height Adjustment High to Low (Natural/Propane Gas) Remote Flame Height Adjustment
More informationPAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting
PAGE 1 This document outlines questions to ask and components to check during TES troubleshooting. More detailed troubleshooting procedures are available in the TES Troubleshooting Guide. 1. Flow Light
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS PROPANE GAS CONVERSION KIT Standard Altitude Only / 0 2000 FT (0 610m) Small Package Products / 40,000 130,000 Btu/hr NPLPCONV013C00 This kit is used on: Two Stage Models: PGR5
More informationELITE 2-BURNER PROPANE BARBECUE Assembly Manual
ELITE 2-BURNER PROPANE BARBECUE Assembly Manual 85-3136-8 (G36402) Propane 1 Year limited Warranty Read and save manual for future reference. Assemble your grill immediately. Missing or damaged parts claims
More informationSAVANNAH EI & DELUXE SYSTEM TROUBLE SHOOTING GUIDE
SAVANNAH EI & DELUXE SYSTEM TROUBLE SHOOTING GUIDE ***PLEASE MAKE SURE TO LEARN THE REMOTE TO THE SYSTEM (REFER TO PG 6) AND CHECK THE BATTERIES FIRST!!! (American Flame AF-4000 Series) Intermittent Pilot
More informationPOCKET GUIDE for TROUBLESHOOTING Gas Products To be used by F.P.I. trained service technicians only.
POCKET GUIDE for TROUBLESHOOTING Gas Products To be used by F.P.I. trained service technicians only. 908-489 02/26/99 Table of Contents Tools and Instruments...3 Problem A Pilot not igniting after repeated
More informationf i r e - p a r t s. c o m
A M E R I C A N F L A M E A F AF-4000 Series Electronic Gas Control Valve APPLICATION The AF-4000 Electronic Gas Control Valve is designed for use in gas in hearth products, wall mount furnaces, and space
More informationSERVICE MANUAL RRG SERIES HEAVY DUTY GAS GRIDDLE - NOTICE - ML ML ML RRG Shown
SERVICE MANUAL RRG SERIES HEAVY DUTY GAS GRIDDLE 24RRG 36RRG 48RRG 60RRG ML-135339-00024 ML-135340-00036 ML-135341-00048 ML-135342-00060 24RRG Shown - NOTICE - This Manual is prepared for the use of trained
More informationAUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS APK-17 PILOT KITS
INSTALLATION & OWNER S MANUAL AUTOMATIC REMOTE LIGHTING SAFETY PILOT SYSTEM WITH VARIABLE FLAME-HEIGHT REMOTE FOR NATURAL OR PROPANE GAS Models: APK-17(M)(P) FEATURES: CONTROL OPERATED ON/OFF VARIABLE
More informationTroubleshooting Guide
Troubleshooting Guide This guide contains information for identifying and correcting issues that may arise. Applicable Models: i200 i200p i250 i250p i200x i201x i250x i251x iq251 iq251d iq751 iq1001 iq1501
More informationSELECT 4-BURNER PROPANE BARBECUE Assembly Manual
SELECT 4-BURNER PROPANE RBECUE Assembly Manual 85-3064-8 (G43257) Propane 1 Year limited Warranty Read and save manual for future reference. Assemble your grill immediately. Missing or damaged parts claims
More informationf i r e - p a r t s. c o m
GNDC36, GNDC36L, & S.I.T Novus 36 Gas Fireplace - DV 1 2 8 3 9 10 11 4 5 12 13 6 IMPORTANT: THIS IS DATED INFORMATION. Parts must be ordered from a dealer or distributor. Hearth and Home Technologies does
More information2.0 Burner Operating Parameters and Requirements
ECLIPSE INFORMATION GUIDE Silicon Carbide Radiant Auto-Recupes Info 322 2/99 WARNING Handle silicon carbide tubes carefully. Do not drop them or hammer on them. Although they feature excellent mechanical
More informationGAS FIRED BROILERS E36W36 E236W36 E43W36 E243W36 E136W36 EC36 EV136W36 EC45
DESIGN C E R T IF I E D THE MONTAGUE CO. SERVICE & PARTS MANUAL GAS FIRED BROILERS E36W36 E236W36 E43W36 E243W36 E136W36 EC36 EV136W36 EC45 NOTICE This manual is prepared for the use of Service Technicians
More informationAmerican Flame AF-4000 Series Intermittent Pilot Ignition System Trouble Shooting Guide
American Flame AF-4000 Series Intermittent Pilot Ignition System Trouble Shooting Guide Contents IPI System Overview Pgs. 2-5 Module Audible Alerts Pgs. 6-7 Module Error Codes Pgs. 8-9 Extension Module
More informationSERVICE INSTRUCTIONS KEATING keatingofchicago.com
SERVICE INSTRUCTIONS 1-800-KEATING keatingofchicago.com FIELD REPLACEMENT KIT - for replacing Flame Switch 037406 and Hardware with Spark Ignition Module For use on all 14" rear drain and all larger size
More informationAssemble your grill immediately. Missing or damaged parts should be claimed within 30 days of purchase.
SSEMLY MNUL Cuisinart CERMIC SMLL SPCES 85-3112-4 (G35801) Propane 85-3113-2 (G35802) Natural Gas Read and save manual for future reference. ssemble your grill immediately. Missing or damaged parts should
More informationCUISINART C790SR Assembly Manual
TM Manual Revision #: 17052011 PD CUISINRT C790SR ssembly Manual 85-3032-4 (G51217) Propane 85-3033-2 (G51218) Natural Gas LIMITED 5-YER WRRNTY Read and save manual for future reference. ssemble your grill
More information¾ open ended wrench ¼ nut driver. 7/16 open ended wrench (Natural Gas Only) 1
These are the pictorial instructions for changing out a suspect valve with the replacement valve assembly that you have received from Atwood. For LP please begin at slide #2 For Natural Gas please begin
More informationN-084M and N-069M-DV Series Heat Exchanger Replacement
N-084M and N-069M-DV Series Heat Exchanger Replacement Models Include: N-069M-DV, N-084M, N-084M-DV N-084M-ASME, N-084M-DV-ASME This instructional manual is only intended for use by a qualified service
More informationSERVICE INSTRUCTIONS KEATING keatingofchicago.com
SERVICE INSTRUCTIONS 1-800-KEATING keatingofchicago.com FIELD REPLACEMENT KIT - for replacing Flame Switch 037406 with External Spark Module Box Assembly For use on all 10x11 fryers, 14" Front Drain fryers
More informationCUISINART C780sR Assembly Manual
TM Manual Revision #: 23102009 PD CUISINRT C780sR ssembly Manual 85-3032-4 (G51213) Propane 85-3033-2 (G51214) Natural Gas Limited 5-Year Warranty Read and save manual for future reference. ssemble your
More informationPRIME 3-BURNER PROPANE BARBECUE Assembly Manual
PRIME 3-BURNER PROPANE BARBECUE Assembly Manual 85-3135-0 / G32010 1 Year limited Warranty Read and save manual for future reference. Assemble your grill immediately. Missing or damaged parts claims must
More informationSection 7 - Troubleshooting Guide
Section 7 - Troubleshooting Guide Section 7 - Troubleshooting Guide IMPORTANT While this troubleshooting guide provides information to aid in troubleshooting problems with the range, it does not contain
More informationELECTROLUX HOME PRODUCTS NORTH AMERICA SERVICE MANUAL. Outdoor Gas Grill. White-Westinghouse
ELECTROLUX HOME PRODUCTS NORTH AMERICA SERVICE MANUAL Outdoor Gas Grill White-Westinghouse 5995420543 March 2005 1 SAFE SERVICING PRACTICES - ALL APPLIANCES To avoid personal injury and/or property damage,
More informationSERVICE MANUAL (INTERNATIONAL)
SERVICE MANUAL (INTERNATIONAL) IMPINGER CONVEYOR OVENS MODEL 1433-000-E, 1434-000-E, 1456, 1457 WITH PUSH BUTTON CONTROLS Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804
More informationRANGER 900 POWER STEERING KIT
RANGER 900 POWER STEERING KIT P/N 2880083 APPLICATION MY14 AND NEWER RANGER XP 900 MODELS IMPORTANT It is strongly recommended that this kit be installed by an authorized Polaris dealer. NOTE Use of this
More informationTO BE USED ONLY BY AUTHORISED PERSONNEL
SERVICE MANUAL for BOSTON (MG 3000 STD) SANTA FE (CALGARY, MG 3000 FLS) & ODESSA (PG 3000) GAS FIRES TO BE USED ONLY BY AUTHORISED PERSONNEL PART No 588402 Issue E Nov. 2001 CONTENTS TROUBLESHOOTING Page
More informationPRIME 3-BURNER PROPANE BARBECUE Assembly Manual
PRIME -BURNER PROPANE RBECUE Assembly Manual 85-15-0 / G2012 1 YEAR LIMITED WARRANTY READ AND SAVE MANUAL FOR FUTURE REFERENCE. Assemble your grill immediately. Missing or damaged parts claims must be
More informationGAS COUNTER EQUIPMENT PARTS / SERVICE MANUAL
THERMA-TEK RANGE CORPORATION QUALITY AND STRENGTH GAS COUNTER EQUIPMENT PARTS / SERVICE MANUAL Models covered in this manual include: Open Top Hot Plates: TCHP12-1, TCHP12-2, TCHP24-2, TCHP24-4, TCHP36-6,
More informationPage 1 of 9 Home Account Contact ALLDATA Log Out Help DAN GRIMWOOD DAN GRIMWOOD00002 Select Vehicle New TSBs Technician's Reference Component Search: OK 1985 Dodge Truck D 350 Pickup V8-360 5.9L VIN I
More informationREAD AND SAVE MANUAL FOR FUTURE REFERENCE. Assemble your grill immediately. Missing or damaged parts should be claimed within 30 days of purchase.
SSEMLY MNUL Cuisinart Gourmet 700 85-3056-8 (G52505) Propane 85-3057-6 (G52506) Natural Gas RED ND SVE MNUL FOR FUTURE REFERENCE. ssemble your grill immediately. Missing or damaged parts should be claimed
More informationWater Supply Valve Maintenance (H4)
Water Supply Maintenance (H4) To service the Water Supply (H4) Seat and Seal in the ANKOM, follow the steps below. 1. Remove the back panel of the instrument. a. Using a 1/8 Allen Wrench, remove the six
More informationReproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.
SERVICE MANUAL GAS BRAISING PANS (30 & 40 GALLON) VG30 VG40 ML-126847 ML-126848 VG40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used by
More informationNatural Gas Conversion Instructions for
CONVERSION INSTRUCTIONS Natural Gas Conversion Instructions for WM16-GBC1405WV WARNING FOR YOUR SAFETY: For Outdoor Use Only (outside any enclosure) WARNING FOR YOUR SAFETY: 1. Improper installation, adjustment,
More informationRemote Flame Height Adjustment Solenoid Hi to Lo (Natural/Propane Gas) Remote Flame Height Adjustment DC Motor Drive Hi to Lo (Natural/Propane Gas)
N N H L N H L A M E R C A N F L A M E A F Electronic Safety System Models: AFVK-SP Manual Flame Height Adjustment Hi to Lo (Natural/Propane Gas) AFVK-SP-H/L AFVK-SP-MH/L (SPLPK-18 or SPLPK-24 Kits are
More informationG600 Series Replacement Intermittent Pilot Ignition Controls
Installation Instructions G600 Issue Date 0601 G600 Series ment Intermittent Pilot Ignition Controls Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing
More informationMODELS GAS-FIRED. Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.
INSTALLATION Instructions AND Owner's Manual OUTDOOR Log Set FOR OUTDOOR GAS FIREPLACES MODELS OLX24WR-1 OLX30WR-1 GAS-FIRED WARNING: If the information in these instructions are not followed exactly,
More informationMASTER SERIES HEAVY DUTY GAS CHAR-BROILER MODELS: MST17B, MST24B, MST34B; MST17BE, MST24BE, MST34BE
Page 86 FORM # Ranges MST Models (Rev 2) MASTER SERIES HEAVY DUTY GAS CHAR-BROILER S:,, ; E, E, E Models:,,, E, E, E 2526000 LP BG Flue Cap 34 1 1 1 2526001 LP BG Flue Cap 24 1 1 2526002 LP BG Flue Cap
More informationODFORTG-36. Service Parts. Log Assembly. Part number list on following page. 12/18. Fortress 36 Outdoor Gas Fireplace
Fortress 36 Outdoor Gas Fireplace Log Assembly 7 3 4 2 6 8 5 1 26 27 24 25 23 22 21 10 9 11 12 13 20 19 14 15 1617 18 Part number list on following page. 12/18 IMPORTANT: THIS IS DATED INFORMATION. Parts
More informationElectronic Safety Pilot System for Vented Gas Logs Models: AFVK-SP AFVK-SP-MH/L
L H L H L A M E R C A N F L A M E A F Electronic Safety System for Vented Gas Logs Models: AFVK-SP AFVK-SP-H/L AFVK-SP-MH/L F YU CANNT READ R UNDERSTAND THESE NSTALLAT NSTRUCTS D NT ATTEMPT T NSTALL R
More informationSELECT 3-BURNER PROPANE BARBECUE Assembly Manual
SELECT 3-BURNER PROPANE BARBECUE Assembly Manual 85-3096-2 (G31221) Propane 1 Year limited Warranty Read and save manual for future reference. Assemble your grill immediately. Missing or damaged parts
More informationInstallation Instructions
40,000-130,000 Btu/hr Part Number: CPLPCONV013C00 SMALL PACKAGED PRODUCTS ACCESSORY PROPANE GAS CONVERSION KIT STANDARD ALTITUDE ONLY 0---2000 FT (0---610 m) Installation Instructions NOTE: Read the entire
More informationS380 Barbecue Assembly Manual
S380 arbecue ssembly Manual 199-9558-8 (G31216) Propane 1 YER LIMITED WRRNTY RED ND SVE MNUL FOR FUTURE REFERENCE. If pre-assembled, leave this manual with unit for consumer s future reference. For product
More informationInstallation Instructions
40,000-130,000 Btu/hr Part Number: 013B00 SMALL PACKAGED PRODUCTS ACCESSORY PROPANE GAS CONVERSION KIT STANDARD ALTITUDE ONLY 0---2000 FT (0---610 m) Installation Instructions This kit is used on: Two
More informationInstallation Instructions
KGANP54011SP Gas Conversion Kit Natural --- to --- Propane for Low---Capacity Gas Furnace 26,000 BTUH Only NOTE: Installation Instructions CERTIFIED Read the entire instruction manual before starting the
More informationX4 Installation and Operation Manual - POWER FLAME INCORPORATED
7.13.2 Set the burner s combustion air inlet damper to the approximate setting as shown in this manual for the desired firing rate. Also, verify that the correct main orifice is installed in the main orifice
More informationPart number list on following page. 08/18
Gas Stove - DV TIARII-CES-IPI, TIARR-IPI, TIARK-IPI Log Set Assembly 4 3 6 5 2 1 8 7 28 12 11 10 9 27 13 14 15 18 19 20 21 22 23 26 25 17 24 16 Part number list on following page. 08/18 IMPORTANT: THIS
More informationCENTRO Assembly Manual (G51206) Propane (G51209) Natural Gas LIMITED 5-YEAR WARRANTY
CENTRO 3900 ssembly Manual -626- (G06) Propane -6-2 (G09) Natural Gas LIMITED -YER WRRNTY Read and save manual for future reference. ssemble your grill immediately. Missing or damaged parts should be claimed
More informationCNXT4236IT, CNXT4236IH
Caliber 36 Gas Fireplace - DV Log Set Assembly 7 3 6 4 8 1 5 2 9 10 11 14 13 12 16 15 17 18 19 28 27 20 21 26 25 22 23 (Valve Assy.) 24 Part number list on following page. 06/17 Log/Grate Assembly 4047-007
More informationSolstice and Solstice Supreme High Efficiency Gas Fryers SG/SSH Series Service Manual
Solstice and Solstice Supreme High Efficiency Gas Fryers SG/SSH Series Service Manual Notice In the event of problems or questions about your order, contact the Pitco Frialator factory at (603) 225-6684.
More informationOWNER'S MANUAL WARNING DANGER. Propane cylinders sold separately. The propane cylinder must be disconnected when this firebowl is not use.
OWNER'S MANUAL READ BEFORE USE! Model No.: BH5003-3 Style No.: 66646 For Outdoor Use Only! Use Propane Gas Only! Propane cylinders sold separately. USE PROPANE GAS ONLY! -Do not store or use gasoline or
More informationAssemble your grill immediately. Missing or damaged parts should be claimed within 30 days of purchase.
SSEMLY MNUL Cuisinart Gourmet 750 85-3122-0 (G53505) Propane 85-3123-8 (G53506) Natural Gas Read and save manual for future reference. ssemble your grill immediately. Missing or damaged parts should be
More informationTECHNICAL MANUAL WENDY'S RANGE MODEL: C0300HT AND C0301 HT
southbend TECHNICAL MANUAL A MIDDLEBY COMPANY WENDY'S RANGE MODEL: C0300HT AND C0301 HT This manual is intended for the use of Southbend Authorized Service Agencies and their associates. Service work should
More information100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE
100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE Start-up must be performed by a trained, experienced service person. The following general start-up
More informationSAVE THESE INSTRUCTIONS
OPERATION MANUAL WARHORSE IMPORTANT SAFETY INSTRUCTIONS WARNING: Failure to observe these instructions can cause personal injury to machine operator or bystanders. WARNING: Asphyxiation Hazard. An improperly
More informationTOYOTA TACOMA EC REARVIEW MIRROR Preparation
Preparation Part Number: PT374-35052 Kit Contents Item # Quantity Reqd. Description 1 1 AD Mirror Assembly 2 1 Hardware bag Hardware Bag Contents Item # Quantity Reqd. Description 1 1 T-tap Connectors,
More informationInstallation Kitchen Faucet Filtration System Instructions GXK285JBL
Installation Kitchen Faucet Filtration System Instructions GXK285JBL BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT Save these instructions for local inspector s use. IMPORTANT
More information