DN9C. Up to 9 contacts 30 A / 415 V max. IP54/IP55 Metal page 74. Up to 7 contacts 25 A / 500 V max. IP66/IP67 GRP or metal page 72
|
|
- Allen Harrington
- 6 years ago
- Views:
Transcription
1 PN7C DN9C PN12C Up to 7 contacts 25 A / 500 V max. GRP or metal page 72 Up to 9 contacts 30 A / max. IP54/IP55 Metal page 74 Up to 12 contacts 16 A / 480 V max. GRP or metal page 76 70
2 RANGE SIGNAL & CONTROL MARECHAL multicontact connectors are used for signal and control applications such as temporary phone lines and control of overhead cranes. The solid silver-nickel contacts assure superior conductivity, electrical performance and durability. Also the materials used for the bodies resist extreme conditions in harsh environments. Find all information on our website: MULTI marechal.com Technical documentation Product configurator DN20C DSN24C DSN37C Up to 20 contacts 25 A / max. IP54/IP55 Metal page 78 Up to 24 contacts 16 A / max. GRP page 80 Up to 37 contacts 16 A / max. GRP page 82 71
3 PN7C MULTI-CONTACT CONNECTORS GRP OR METAL 16/25 A WALL MOUNTING SOCKET PN7C TYPICAL CONFIGURATION PLUG PN7C 01NA053 Straight handle poly 01NA013 Socket-outlet 01P4061 Inlet 01P8061 MAIN FEATURES Rated current/contact (wiring according to standard) of currents (contacts) Maximum voltage IP protection lid closed IP protection connected plug Shock resistance (poly casing) 25 A 130 A 500 V IK08 Shock resistance (metal casing) IK09 Ambient temperature -40 C to +60 C Flexible wiring (min-max) 1-4 mm 2 Stranded wiring (min-max) 1-6 mm 2 Wiring (terminals) screw-type Keying positions 5 Umax Polarity Part no. Part no. 500 V 500 V 500 V SOCKET- OUTLET female PN7C (16/25 A) GRP INLET male PN7C (16/25 A) GRP 5P (25 A)01P405001P8050 6P (16 A)01P406001P8060 7P (16 A)01P407001P8070 4P+E (25 A)01P404101P8041 5P+E (25 A)01P405101P8051 6P+E (16 A)01P406101P8061 Note: When using two different voltages on the same site, thank you for contacting us. SOCKET- OUTLET female PN7C (16/25 A) METAL Umax Polarity Part no. Part no. INLET male PN7C (16/25 A) METAL 5P (25 A)09P405009P8050 6P (16 A)09P406009P8060 7P (16 A)09P407009P8070 4P+E (25 A)09P404109P8041 5P+E (25 A)09P405109P8051 6P+E (16 A)09P406109P
4 MULTI BOXES Cable gland not included Entry poly straight metal straight inclined metal 45 poly + inclined poly 70 M20 01NA053 01NA055 09NA055 09NA653 Not drilled and M25 M32 09NA NA without cable gland Part no. 51AA058 SLEEVES metal 30 poly A057 09NA027 51AA757 HANDLES Angled poly with poly cable gland Straight metal with metal cable gland without cable gland with metric threaded entry 9-18 mm01na013 01NA mm01na mm09na963 M2001NA mm 611A mm01na25325p8-16 mm09na95325m M2501NA mm01na25332p16-24 mm09na95332m M3201NA Locking with padlock (ø 4 mm) without shaft (padlocks not supplied) Socket no Screw locking imprint BTR 2,5 Socket no Reversed interior and contacts (inlet cap is included) Inlet no Socket no IP55 self-closing lid (Socket-outlet) Replace P by S Eg: 400 V 3P+N+E poly = 01S4017 Inlet cap 01NA126 Self-returning lid Socket no. + R 180 opening lid Socket no opening and self-returning lid Socket no
5 DN9C METAL MULTI-CONTACT CONNECTORS 30 A IP55 WALL MOUNTING SOCKET DN9C TYPICAL CONFIGURATION PLUG DN9C metal A053 Straight handle poly 191A013 Socket-outlet Inlet MAIN FEATURES Rated current/contact (wiring according to standard) of currents (contacts) Maximum voltage IP protection lid closed IP protection connected plug Shock resistance 30 A 210 A IP55 IP54 IK09 Ambient temperature -40 C to +60 C Flexible wiring (min-max) 1-6 mm 2 Stranded wiring (min-max) 1,5-10 mm 2 Wiring (terminals) screw-type Keying positions 2 SOCKET- OUTLET female DN9C (30 A) INLET male DN9C (30 A) Note: When using two different voltages on the same site, thank you for contacting us. Umax Polarity Part no. Part no. 6P P P P P+E P+E P+E P+E AUXILIARY CONTACTS Including 2 pilot contacts (30 A) Socket no Including 2 pilot contacts (30 A) Inlet no Including 4 pilot contacts (30 A) Socket no Including 4 pilot contacts (30 A) Inlet no
6 DN MULTI BOXES Cable gland not included Entry metal 20 inclined metal 70 inclined metal 30 M20 191A A A A095 straight metal sleeve M25 191A A A A M32 191A A A A M40 873A A A SLEEVES metal 30 metal 70 Straight metal 191A A A127 HANDLES with poly cable gland Straight metal with metal cable gland without cable gland with metric threaded entry mm191a mm 191A mm 191A963 M20 191A mm 191A473* 9-18 mm 191A25325P 8-16 mm 191A95325M M25 191A mm 191A25332P mm 191A95332M M32 191A mm 191A25340P mm 191A95340M M40 191A *With built-in finger draw plate (recommended for inline connections) Locking with shaft for 3 padlocks ø 8 mm (padlocks not supplied) Socket no Lockable plug: contact us Padlocking device 1 to 6 padlocks 873A541 E-Stop button Socket no Inlet cap 191A opening lid Socket no Self-returning lid Socket no. + R 180 opening and self-returning lid Socket no (socket & inlet) Part no
7 PN12C MULTI-CONTACT CONNECTORS GRP OR METAL 16 A WALL MOUNTING SOCKET PN12C TYPICAL CONFIGURATION PLUG PN12C 01NA053 Straight handle poly 01NA013 Socket-outlet 01A4001 Inlet 01A8001 ELECTRICAL FEATURES Maximum voltage 480 V Impulse withstand voltage 5 kv / Pollution degree 3 Contact resistance 2mΩ Permited current range 4-20 ma / 16 A Rated current percontact (max) 16 A Total current carried 110 A Flexible wiring (min-max) 1-2,5 mm 2 Wiring (terminals) Crimp type terminals (tool optional) or directly soldered Keying positions 2 CLIMATIC FEATURES Ambient temperature IP protection connected plug IP protection lid closed Salt, Fog performance Resistance to fluids -40 C to +60 C 200 hrs minimum connected Motor oils, petrol, fats, detergents... MECHANICAL FEATURES Butt contacts Female contacts: copper alloy silver plated / Male contacts: Silver-nickel tips Contact protection Silvering Load cycles More than 5000 cycles Shock resistance (poly casing) IK08 Shock resistance (metal casing) IK09 Vibration Frequency Hz, 1g / (90 minutes on each critical frequency) according to IEC SOCKET- OUTLET female PN12C (16 A) INLET male PN12C (16 A) Umax Contacts Part no.* Part no.* 480 V 12 contacts 01A A8001 * The listed Part nos. call up GRP casings. For metal casings, replace prefix 01 with 09 Each product is supplied with 1 bag of 13 contacts depending on the maximum configuration. This allows you to configure the product as required. BAG OF 13 CONTACTS (SUPPLIED WITH INSULATION SLEEVES AND FERRULES) Female socket-outlet Part Number Male inlet Part Number 01AA213 01AA113 76
8 MULTI BOXES Cable gland not included Entry poly straight metal straight inclined metal 45 poly + inclined poly 70 M20 01NA053 01NA055 09NA055 09NA653 Not drilled and M25 M32 SLEEVES 09NA NA without cable gland Part no. 51AA058 HANDLES metal 30 poly A057 09NA027 51AA757 Angled poly with poly cable gland Straight metal with metal cable gland without cable gland with metric threaded entry 9-18 mm01na013 01NA mm01na mm09na963 M2001NA mm 611A mm01na25325p8-16 mm09na95325m M2501NA mm01na25332p16-24 mm09na95332m M3201NA Locking with padlock (ø 4 mm) without shaft (padlocks not supplied) Socket no Screw locking imprint BTR 2,5 Socket no Crimping tool 61CA500 Helavia sleeve expansion tool Bag of 13 heat shrink insulation sleeves 61CA400 61CA083 Reversed interior and contacts (inlet cap is included) Inlet no Socket no Inlet cap 01NA126 Self-returning lid Socket no. + R 180 opening lid Socket no opening and self-returning lid Socket no
9 DN20C METAL MULTI-CONTACT CONNECTORS 25 A IP55 WALL MOUNTING SOCKET DN20C TYPICAL CONFIGURATION PLUG DN20C metal A653 Straight elastomer 659A013D35 Socket-outlet Inlet MAIN FEATURES Rated current/contact (wiring according to standard) of currents (contacts) Maximum voltage IP protection lid closed IP protection connected plug Shock resistance 25 A 350 A IP55 IP54 IK09 Ambient temperature -40 C to +60 C Flexible wiring (min-max) 1-6 mm 2 Stranded wiring (min-max) 1,5-10 mm 2 Wiring (terminals) screw-type Keying positions 4 SOCKET- OUTLET female DN20C (25 A) INLET male DN20C (25 A) Note: When using two different voltages on the same site, thank you for contacting us. Umax Polarity Part no. Part no. 10P P P P P P P P P P P P+E P+E P+E P+E P+E P+E P+E P+E P+E P+E P+E
10 DN MULTI BOXES Cable gland not included Entry inclined metal 70 inclined metal 30 straight metal sleeve M32 879A A A M40 879A A A M50 879A A A095 M63 879A A A SLEEVES metal 30 metal 70 Straight metal 196A A A127 HANDLES* Straight elastomer with metal cable gland Straight metal with metal cable gland without cable gland with metric threaded entry mm 659A013D mm 619A25363M16-24 mm 196A95332MM63 619A mm 659A013D mm 196A mm 659A013D mm 196A95350M * For use at 135 C, use only metal handles. Locking with shaft for 3 padlocks ø 8 mm (padlocks not supplied) Socket no Lockable plug: contact us Padlocking device 1 to 6 padlocks 873A541 E-Stop button Socket no Inlet cap 196A126 Closing mechanism Draw lever only: 196A376 Draw plate only: 196A opening lid Socket no Self-returning lid Socket no. + R 180 opening and self-returning lid Socket no (socket & inlet) Socket no
11 DSN24C MULTI-CONTACT CONNECTORS GRP 16 A WALL MOUNTING SOCKET DSN24C TYPICAL CONFIGURATION PLUG DSN24C poly 70 51BA058 Straight handle poly 613A013 Socket-outlet 61B4002 Inlet 61B8002 ELECTRICAL FEATURES Maximum voltage 480 V Impulse withstand voltage 5 kv / Pollution degree 3 Contact resistance 2mΩ Permited current range 4-20 ma / 16 A Rated current percontact (max) 16 A Total current carried 230 A Flexible wiring (min-max) 1-2,5 mm 2 Wiring (terminals) crimping Keying positions 1 CLIMATIC FEATURES Ambient temperature IP protection connected plug IP protection lid closed Salt, Fog performance Resistance to fluids -40 C to +60 C 200 hrs minimum connected Motor oils, petrol, fats, detergents... MECHANICAL FEATURES Butt contacts Female contacts: copper alloy silver plated / Male contacts: Silver-nickel tips Contact protection Silvering Load cycles More than 5000 cycles Shock resistance IK08 Vibration Frequency Hz, 1g / (90 minutes on each critical frequency) according to IEC SOCKET- OUTLET female DSN24C (16 A) INLET male DSN24C (16 A) Umax Contacts Part no. Part no. 480 V 24 contacts 61B B8002 Each product is supplied with 2 bags of 13 contacts depending on the maximum configuration. This allows you to set up the product to suit your needs. BAG OF 13 CONTACTS (SUPPLIED WITH INSULATION SLEEVES AND FERRULES) Female socket-outlet Part Number Male inlet Part Number 01AA213 61CA113 80
12 MULTI DN BOXES Cable gland not included inclined straight metal sleeve poly + inclined poly 70 Entry M20 613A A A095 Not drilled and M25 613A A A without cable M32 613A A gland M40 613A A Part no. 51BA058 SLEEVES poly 70 Straight metal 613A027 51BA A127 HANDLES with poly cable gland Straight metal with metal cable gland without cable gland with metric threaded entry 5-21 mm613a mm 613A mm 613A963M20 613A mm 613A25325P 8-16 mm 613A95325M M25 613A mm 613A25332PM32 613A mm 613A25340PM40 613A Locking with shaft for 3 padlocks ø 4 mm (padlocks not supplied) Socket no Locking with shaft for 2 padlocks ø 8 mm (padlocks not supplied) Socket no. + Z1646 Lockable plug: contact us Crimping tool 61CA500 Helavia sleeve expansion tool Bag of 13 heat shrink insulation sleeves 61CA400 61CA083 E-Stop button Socket no Inlet cap 613A426 Closing mechanism (in-line connections) (a pair of finger draw plates) 613A opening lid Socket no Self-returning lid Socket no. + R 180 opening and self-returning lid Socket no
13 DSN37C MULTI-CONTACT CONNECTORS GRP 16 A WALL MOUNTING SOCKET DSN37C TYPICAL CONFIGURATION PLUG DSN37C poly 70 51CA058 Straight handle poly 616A013 Socket-outlet 61C4003 Inlet 61C8003 ELECTRICAL FEATURES Maximum voltage 480 V Impulse withstand voltage 5 kv / Pollution degree 3 Contact resistance 2mΩ Permited current range 4-20 ma / 16 A Rated current percontact (max) 16 A Total current carried 360 A Flexible wiring (min-max) 1-2,5 mm 2 Wiring (terminals) crimping Keying positions 3 CLIMATIC FEATURES Ambient temperature IP protection connected plug IP protection lid closed Salt, Fog performance Resistance to fluids -40 C to +60 C 200 hrs minimum connected Motor oils, petrol, fats, detergents... MECHANICAL FEATURES Butt contacts Female contacts: copper alloy silver plated / Male contacts: Silver-nickel tips Contact protection Silvering Load cycles More than 5000 cycles Shock resistance IK08 Vibration Frequency Hz, 1g / (90 minutes on each critical frequency) according to IEC SOCKET- OUTLET female DSN37C (16 A) INLET male DSN37C (16 A) Umax Contacts Part no. Part no. 480 V 37 contacts 61C C8003 Each product is supplied with 3 bags of 13 contacts depending on the maximum configuration. This allows you to set up the product to suit your needs. BAG OF 13 CONTACTS (SUPPLIED WITH INSULATION SLEEVES AND FERRULES) Female socket-outlet Part Number Male inlet Part Number 01AA213 61CA113 82
14 DN MULTI BOXES Cable gland not included Entry inclined straight metal sleeve inclined metal 70 poly + inclined poly 70 M25 616A A A A053 Not drilled and M32 616A A A M40 616A A A without cable gland Part no. 51CA058 SLEEVES poly 70 Straight metal metal A027 51CA A A087 HANDLES with poly cable gland Straight metal with metal cable gland without cable gland with metric threaded entry mm 616A mm 616A25320P 7-13 mm 616A95320M M20 616A mm 616A473* 9-18 mm 616A mm 616A963 M25 616A mm 616A25332P mm 616A95332M M32 616A mm 616A25340P mm 616A95340M M40 616A *With built-in finger draw plate (recommended for inline connections) Locking with shaft for 3 padlocks ø 4 mm (padlocks not supplied) Socket no Locking with shaft for 2 padlocks ø 8 mm (padlocks not supplied) Socket no. + Z1646 Lockable plug: contact us Crimping tool 61CA500 Helavia sleeve expansion tool Bag of 13 heat shrink insulation sleeves 61CA400 61CA083 E-Stop button Socket no Inlet cap 616A426 Closing mechanism (in-line connections) (a pair of finger draw plates) 616A opening lid Socket no Self-returning lid Socket no. + R 180 opening and self-returning lid Socket no
MULTICONTACT. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates
MULTICONTACT Number of connections up to 2000 matings. Very good resistance to vibrations. Resistance to current fluctuation. Resistance to corrosion. Solid silver-nickel contacts assure superior conductivity.
More informationDNROBUST DECONTACTOR 20 A / 30 A / 50 A / 90 A / 150 A SILVER-NICKEL BUTT CONTACTS
DNROBUST DECONTACTOR 20 A / 30 A / 50 A / 90 A / 150 A AUTOMATIC IP54/ WATER- AND DUST-TIGHT IMPACT-RESISTANT METAL CASING SUITABLE FOR HEAVY INDUSTRY The DN family of decontactors cover ratings from 30
More informationDECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A
DECONTACTOR FOR INDUSTRY 30 A / 50 A / 90 A / 150 A / 250 A SAFE AND SIMPLE CONNECTION, EVEN AT 250 A SAFETY SHUTTER GRP OR METAL CASING The DS family of decontactors offer ratings from 30 to 250 A (ratings
More informationINDUSTRIAL PLUGS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates
INDUSTRIAL PLUGS A range from 16 A to 600 A 1000 V. Automatic watertightness from IP44 to 66/67. From -40 to +240 C. GRP or metal casing. Reliable & compact. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com
More informationSWITCH SHOULD BE ON THE UPPER SIDE!
COMPACT AND WATERTIGHT DECONTACTOR 20 A / 32 A / 63 A AUTOMATIC WATER- AND DUST-TIGHT SEALING AC-22 AND AC-23 BREAKING CAPACITY IMPACT-RESISTANT GRP CASING With sizes from 20 to 63 A, DSN decontactors
More informationSWITCH SHOULD BE ON THE UPPER SIDE!
COMPACT AND WATERTIGHT DECONTACTOR 20 A / 32 A / 63 A AUTOMATIC WATER- AND DUST-TIGHT SEALING AC-22 AND AC-23 BREAKING CAPACITY IMPACT-RESISTANT GRP CASING With sizes from 20 to 63 A, DSN decontactors
More information20 A / 32 A / 63 A DECONTACTOR MOUNTING: SWITCH SHOULD BE ON THE UPPER SIDE!
COMPACT AND WATERTIGHT DECONTACTOR 20 A / 32 A / 63 A AUTOMATIC ip66/ip67 water- and dust-tight sealing AC-22 and ac-23 breaking capacity Impact-resistant GRP casing With sizes from 20 to 63 A, DSN decontactors
More informationWATER & WASTE WATER INDUSTRIES
WATER & WASTE WATER INDUSTRIES INDUSTRIAL PLUGS & SOCKET-OUTLETS hyconelec.co.za MARECHAL TECHNOLOGY SAFE AND RELIABLE ELECTRICAL CONNECTIONS IDEALLY SUITED TO THE WATER & WASTE WATER INDUSTRIES. MARECHAL
More informationMOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS. hyconelec.co.za MARECHAL TECHNOLOGY
MOTOR CONNECTIONS MOTOR-DECONTACTOR & INDUSTRIAL PLUGS & SOCKET-OUTLETS hyconelec.co.za MARECHAL TECHNOLOGY SAFE AND RELIABLE ELECTRICAL CONNECTIONS FOR YOUR MOTORS. MARECHAL ELECTRIC offers a range of
More informationINDUSTRIAL DECONTACTOR & CONNECTOR SYSTEMS
COLTERLEC ELECTRICL ENGINEERING PRODUCTS SECTION INDUSTRIL DECONTCTOR & CONNECTOR SYSTEMS Industrial Decontactor & Connector Systems COLTERLEC ELECTRICL ENGINEERING PRODUCTS 385 TM Industrial Decontactors
More informationDECONTACTOR. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates
DECONTACTOR Switch with socket-outlet. The plugs and sockets as well as socket-outlet boxes and junction boxes in this range are meant for use in hazardous areas in compliance with the ATEX 2014/35/EU
More informationPXN12C DXN25C DXN37C MULTI-CONTACT CONNECTORS 10 A TECHNICAL FEATURES
PXN12C DXN25C DXN37C MULTI-CONTACT CONNECTORS II2 G D Ex e ia or ib IIC FROM 12 TO 37 CONTACTS LOCKING IN CONNECTED OR DISCONNECTED POSITION CORROSION-FREE METAL CASING TECHNICAL FEATURES PXN12C DXN25C
More informationDSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A
DSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A Automatic IP66/IP67/IP69k AC-22 and ac-23 breaking capacity Chemical resistant GRP UL 94 casing Impact resistance IK08, vibration resistance -40
More informationDECONTACTOR SWITCH WITH SOCKET-OUTLET
DECONTACTOR SWITCH WITH SOCKET-OUTLET This extensive and comprehensive product range covers all industrial applications. With sizes up to 400 A, it offers a wide range of mounting and installation options.
More informationDSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A
DSN COMPACT AND WATERTIGHT DECONTACTOR GRP 20 A/32 A/63 A Automatic IP66/IP67/IP69k AC-22 and ac-23 breaking capacity Chemical resistant GRP UL 94 casing Impact resistance IK08, vibration resistance -40
More informationINDUSTRIAL PLUGS & SOCKET-OUTLETS DECONTACTOR & BOXES
INDUSTRIAL PLUGS & SOCKET-OUTLETS DECONTACTOR & BOXES EXPLOSION-PROOF PLUGS & SOCKETS MULTICONTACT CONNECTORS HIGH CURRENT PLUGS & SOCKETS HIGH TEMPERATURE marechal.com CONTENT INDUSTRIAL POWER SUPPLY
More informationINDUSTRIAL PLUGS & SOCKET-OUTLETS DECONTACTOR & BOXES
INDUSTRIAL PLUGS & SOCKET-OUTLETS DECONTACTOR & BOXES EXPLOSION-PROOF PLUGS & SOCKETS MULTICONTACT CONNECTORS HIGH CURRENT PLUGS & SOCKETS HIGH TEMPERATURE marechal.com CONTENT INDUSTRIAL POWER SUPPLY
More information20 A / 32 A / 63 A DECONTACTOR MOUNTING: SWITCH SHOULD BE ON THE UPPER SIDE!
& WATERTIGHT DECONTACTOR DXNCOMPACT 20 A / 32 A / 63 A II2 G D Ex de IIC WATER- AND DUST-TIGHT INTEGRATED LOAD-BREAK SWITCH ROBUST AND COMPACT DESIGN HIGH PERFORMANCE POLY CASING DXN decontactors are designed
More informationPORTS, MARINAS, SHIPYARDS & VESSELS
PORTS, MARINAS, SHIPYARDS & VESSELS INDUSTRIAL PLUGS & SOCKET-OUTLETS SAFE AND RELIABLE ELECTRICAL CONNECTIONS IDEALLY SUITED TO PORTS, MARINAS, SHIPYARDS & VESSELS MARECHAL ELECTRIC offers a range of
More informationINDUSTRIAL PLUGS & SOCKET-OUTLETS DECONTACTOR & BOXES
INDUSTRIAL PLUGS & SOCKET-OUTLETS DECONTACTOR & BOXES EXPLOSION-PROOF PLUGS & SOCKETS MULTICONTACT CONNECTORS HIGH CURRENT PLUGS & SOCKETS HIGH TEMPERATURE marechal.com CONTENT INDUSTRIAL POWER SUPPLY
More informationMechanical features. Spring-loaded elastic terminals: resist vibrations
DXN 20 A 32 A 63 A Explosive atmospheres as standard Compact & robust design Safe & easy operation DXN decontactors are designed for explosive atmospheres, with de protection mode. They comply with the
More informationHEAVY-DUTY PLUGS & SOCKETS
HEAVY-DUTY PLUGS & SOCKETS 315 A/400 A/500 A/600 A Up to 600 A/1 000 V Automatic IP66/IP67 water-and dust-tight Mechanical and electrical interlocking Up to 6 auxiliary and 2 pilot contacts Marine aluminum
More informationSwitch rated plugs and receptacles with nema 4X protection
DSn Features and Ratings p. 24 DSN20 p. 25 DSN30 p. 27 DSN60 p. 29 Spare parts p. 31 Dimensions p. 33 23 Switch rated plugs and receptacles with nema 4X protection DSN Series products are switch and hp
More informationProducts for. Section
2 Products for Section Chemical Industries Grain silos Oil and Gas industry Plastics Fertilisers and insecticides Wood Cosmetics and perfumes lcohol and spirits Pharmaceutical Industries, etc. 90 2005-2006
More informationDSN. Switch-rated plug and receptacle with Type 4X protection
DSN Features and Ratings p. 24 DSN20 p. 25 DSN30 p. 27 DSN60 p. 29 DSN150 p. 31 Spare parts p. 33 Dimensions p. 35 Switch-rated plug and receptacle with Type 4X protection DSN Series products are switch
More informationSOCKET-OUTLETS WITH PROTECTION
BM MODULAR BOXES Assembly from 1 to 6 modules IP66/IP67 sealing 1 or 2 cable glands per side Range of protection levels available page 112 CD SOCKET-OUTLETS WITH PROTECTION From 16 up to 63 A RCD protection
More informationSwitch rated plugs and receptacles
DS Features and Ratings p. 36 DS20 p. 37 DS30 p. 39 DS60 p. 41 DS100C p. 43 DS100 p. 45 DS200 p. 47 Spare parts p. 49 Dimensions p. 51 35 Switch rated plugs and receptacles DS Series Decontactors provide
More informationRobust construction and high amperage capabilities
DR Features and Ratings p. 94 DR30 p. 95 DR50 p. 97 DR100 p. 99 DR150 p. 101 DR 250 p. 103 DR400 p. 105 Spare parts p. 107 Dimensions p. 109 Robust construction and high amperage capabilities DR series
More information315 A / 400 A / 500 A / 600 A
PF HEAVY-DUTY PLUGS & SOCKETS 315 A / 400 A / 500 A / 600 A UP TO 600 A / 1000 V AUTOMATIC WATER- AND DUST-TIGHT MECHANICAL AND ELECTRICAL INTERLOCKING UP TO 6 AUXILIARY AND 2 PILOT CONTACTS Big equipment
More informationRobust construction and high amperage capabilities
DR Features and Ratings p. 130 DR30 p. 131 DR50 p. 133 DR100 p. 135 DR150 p. 137 DR 250 p. 139 Spare parts p. 141 Dimensions p. 143 Robust construction and high amperage capabilities 129 DR series plugs
More informationDECONTACTOR FOR INDUSTRY 30 A/50 A/90 A/150 A/250 A/ 400 A
DS DEONTATOR FOR INDUSTRY 30 A/50 A/90 A/150 A/250 A/ 400 A Atomatic IP54/55 Optional IP66 from 90 A Integrated load break switch: A-22 and A-23 breaking capacity hemical resistant GRP UL 94 casing p to
More informationPOWER GENERATION SWITCH RATED ELECTRICAL CONNECTORS FOR INDUSTRY. hyconelec.co.za MARECHAL TECHNOLOGY
POWER GENERATION SWITCH RATED ELECTRICAL CONNECTORS FOR INDUSTRY MARECHAL TECHNOLOGY Connectors designed specifically for your plant operations MARECHAL DECONTACTOR series products combine the safety and
More informationCUSTOMIZED SOLUTIONS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates
CUSTOMIZED SOLUTIONS MARECHAL offers a wide range of distribution boxes for all industrial applications and a large choice of products designed specifically for power-supply in tunnels. FIND ALL INFORMATION
More informationDECONTACTOR FOR INDUSTRY 30 A/50 A/90 A/150 A/250 A/ 400 A
S EONTATOR FOR INUSTRY 30 A/50 A/90 A/150 A/250 A/ 400 A Atomatic IP54/55 Optional IP66 from 90 A Integrated load break switch: A-22 and A-23 breaking capacity hemical resistant GRP UL 94 casing p to 150
More informationSERIES MHV (H4) HIGH VOLTAGE CONNECTORS
SERIES MHV (H4) HIGH VOLTAGE CONNECTORS DESCRIPTION CONTENTS PAGE HUBER+SUHNER MHV connectors are coaxial miniature high voltage (MHV = Miniature High Voltage) connectors with 5 kv rms test voltage (mated
More informationHan-Power Energy Bus Components
HARTING Electric Han-Power Energy Bus Components People Power Partnership Han Data Sheet 0080-7 Han-Power T Han-Power T Part-Number Drawing Dimensions in mm 09 12 008 4701 Cable gland please order separately
More informationBoxes and Socket-outlets for tunnel applications
Boxes and Socket-outlets for tunnel applications Connectors for smoke extraction fans Boxes for emergency lighting (page 4) (page 5 to 7) Without cutting cable The leading range MARECHAL ELECTRIC is a
More informationMAIN OPTIONS DESCRIPTION OF THE KEY OPTIONS OF OUR PRODUCTS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates
MAIN OPTIONS DESCRIPTION OF THE KEY OPTIONS OF OUR PRODUCTS. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com Dimensions and certificates 216 MECHANICAL LOCKING... P. 218 STOP-LATCH... P. 219 TYPOLOGY
More informationATEX Approved Ex Connectors
TEX pproved Ex Connectors 0081 IECEx 2 www.marechal.com - +33 (0)1 45 11 60 00 MRECHL ELECTRIC TEX approved explosion-proof products XN - Compact ECONTCTOR X - Metal ECONTCTOR CRIC - Terminals B2X - istribution
More informationRockStar HighPower. Contents. RockStar HighPower Introduction C.2 C.1
ontents Introduction.2 HighPower 250 A.4 4000 V 250 A 1 4 poles HighPower 550 A.10 4000 V 550 A 1 3 poles.1 Introduction Uncompromising power in clever and safe packaging. The modular high-current connector
More informationSwitch rated connectors for. Ports, Shipyards & Vessels
Switch rated connectors for Ports, Shipyards & Vessels Marechal s DECONTACTOR ideally suited Connect with confidence & disconnect with safety Thanks to its integral load-break isolating switch mechanism,
More informationLimit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.
Presentation Compact design, plastic, with reset knob, types XCNR and XCNTR b XCNR with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page b XCNTR with
More informationSelf-ejecting systems applications
Self-ejecting systems applications Self-ejecting systems avoid the rupturing of an electric circuit when a mobile apparatus is moved without first disconnecting the electrical supply. The applications
More informationWastewater Solutions
Wastewater Solutions Featuring Meltric s Switch-Rated Plugs, Receptacles and Electrical Connectors meltric.com A company of MARECHAL ELECTRIC GROUP Meltric DECONTACTOR TM Series Plugs & Receptacles Decontactors
More informationMagnetic and Hydraulic-Magnetic Circuit Breaker 8340-G V
Description Single and two pole magnetic circuit breakers with trip-free mechanism and push/pull on/off manual actuation. A choice of fast magnetic only or hydraulically delayed switching characteristics
More informationNFPA 70E 68! & CSA Z462
DB Switch-Rated plug and receptacle Main Advantages u Switch & Hp rated u 100 ka short circuit rated* u IP67 environmental ratings u Up to 4 auxiliary contacts u Durable metal construction * See note under
More informationHK-003,HC SERIES HK-003 HCSERIES. Modular Heavy-current connector WAIN 12-01
HK-00, SERIES HK-00 SERIES Modular Heavy-current connector 12-01 HK-00/0HK-00/2 Heavy-current inserts HE-006 HK-00 Technical characteristics Specifications Approvals Inserts Number of contacts Electrical
More informationThermal-Magnetic Circuit Breaker 201/-WA
Thermal-Magnetic Circuit Breaker 0/-WA Description Single pole thermal-magnetic circuit breaker with tease-free, trip-free, snap action mechanism and two button operation (M-type TM CBE to EN 60934). Featuring
More informationMMC RTX series EN3716
MMC RTX series EN3716 7 CONTENTS Page Introduction... 7-4 Application 7-4 Features... 7-4 Product overview... 7-5 Electrical characteristics... 7-6 Mechanical & environmental characteristics... 7-6 Products
More informationSolenoid Locking Safety Switches
HSC HSC Full Size Solenoid Locking Switches Key features: Rugged aluminum die-cast housing 00N locking retention force Flexible Installation: The actuator can be accessed from two directions Select from
More informationEPIC CIRCON M23 Series
M23 Series EPIC EPIC CIRCON M23 Series Application Advantage Rugged nickel-plated, die-cast zinc body Positive vibration protection for use with motor drives and moving assemblies Integral EMC cable gland
More informationHan K 3/0, K 3/2 / Han HC Modular. Contents Technical characteristics Han K 3/0, Han K 3/ Inserts Han K 3/0, Han K 3/
Han K 3/0, K 3/2 / Han HC Contents Page Technical characteristics Han K 3/0, Han K 3/2... 14.02 Inserts Han K 3/0, Han K 3/2... 14.03 Hoods/Housings Han 24 HPR for Han K 3/0, Han K 3/2... 14.04 Technical
More informationAF40... AF96 3-pole contactors Technical data
Main pole - Utilization characteristics according to IEC Standards IEC 60947- / 60947-4- and EN 60947- / 60947-4- Rated operational voltage Ue max. 690 V Rated frequency (without derating) 50 / 60 Hz Conventional
More informationElectronic Circuit Breaker ESS20-0..
Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode
More informationThermal-Magnetic Circuit Breaker 2210-S291-P9M A
Thermal-Magnetic Circuit Breaker 0-S9-P9M-40033-...A Description Single pole thermal-magnetic circuit breaker with trip-free mechanism and toggle actuation. Two-chamber construction with cascade contact
More informationHS5D Miniature Interlock Switches
HS5D Miniature Interlock Switches Head Removal Detection Function for Safer Performance Clearwater Tech - Phone: 8094.04 - Fax: 8.368.04 - Web: www.clrwtr.com - Email: info@clrwtr.com New Generation Miniature
More information13.1. Range of Enclosures. KRONECTION Box A 2 for up to 2 pairs. Expert Knowledge. Short survey of the KRONECTION Box A 2 for up to 2 pairs
KRONECTION Box A 2 for up to 2 pairs Short survey of the KRONECTION Box A 2 for up to 2 pairs The KRONECTION Box A 2, which is equipped with connection contacts on the right and left, serves as a line
More informationLimit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation
Presentation Variable composition Spring-rod lever with thermoplastic end () Spring-rod lever, metal () Variable length thermoplastic roller lever () Round rod lever, thermoplastic, Ø mm L = mm () ZCK
More informationHS1C Interlock Switches with Solenoid
HSC es with The guard door remains locked until the machine stops completely. With the actuator mounted on the guard door and the interlock switch on the machine, the door is mechanically locked when closed.
More informationMagnetic Overcurrent Circuit Breaker
Magnetic Overcurrent Circuit Breaker 808-... Description ngle pole miniaturised magnetic circuit breakers with unique highspeed operating mechanism and push/pull on/off manual actuation. Fitted with electrically
More informationAmphenol SCE2/Terrapin Series
APPLICATIONS TECHNICAL SPECIFICATIONS Amphenol SCE2/Terrapin Series Radios Headsets MATERIALS AND FINISHES Shell Material Shell Plating Contact Material Contact Plating MINIATURE PUSH-PULL CONNECTOR FOR
More informationDS Switch-Rated. plug and receptacle. Main Advantages. DS100 p. 48 DS200 p. 50 Spare parts p. 52 Dimensions p. 54
DS SwitchRated plug and receptacle Main Advantages u Switch & Hp rated (AC only) u 65 ka to 100 ka short circuit rated* u Up to 6 auxiliary contacts u Amperage ratings up to 200A u Metal or Poly construction
More informationLK Position Switches TECHNICAL DATASHEET.
LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions
More informationCL-3/1297 CGL INDUSTRIAL POWER INPUT CONNECTORS UP TO 700 V
CL-3/1297 INDUSTRIAL POWER INPUT CONNECTORS UP TO 700 V Contents Introduction... 2 Features... 3 How to Order... 4 Part Number Explanation... 5 Technical Data... 6 250 / 500 Volt Contact Arrangements...
More informationBOXES AND BOARDS. Versatility and modularity of solutions and materials STANDARD HEAVY DUTY
BOXES AND BOARDS Versatility and modularity of solutions and materials STANDARD HEAVY DUTY 8 BOXES AND BOARDS Versatility and modularity of solutions and materials STANDARD PRIMA topter empty distribution
More information8N45S NC Series Non-safety classified connectors for EPR reactors
Description Quick-connect ¼ turn bayonet coupling mechanism Straight backshell with sealing gland and cable clamp Integrated 60 ground termination mechanism compliant with EPR reactors wiring specifications
More informationCrimpmate Range pitch 5.00
Contents pitch. pitch. pitch. Male and female connectors with solder connection. Male and female connectors with crimp connection. Crimp contacts..1 pitch. RSV 1. S Derating curve RSV1. S SN Rectangular
More informationStandard Interlock Safety Switches
Subminiature Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening Action Actuators comply with
More informationWastewater Solutions. DECONTACTOR TM Series. Featuring Meltric s. Switch Rated Plugs, Receptacles and Electrical Connectors
Wastewater Solutions Featuring Meltric s DECONTACTOR TM Series Switch Rated Plugs, Receptacles and Electrical Connectors Meltric DECONTACTOR TM Series Plugs & Receptacles Decontactors are a combination
More informationWaterproof Series Waterproof
Waterproof Series Waterproof Technical Data Panel connector Panel connector, cable connector and coupler connector circular housing Locking screw connection Protection IP 65 with flat-gasket for panel
More informationLimit switches 3. Page 92. Page 92
Presentation, general characteristics b XCKS with cable entry v With head for linear movement (plunger) Page v With head for rotary movement (lever) Page Environment characteristics Conformity to standards
More informationHS1L Interlock Switches with Solenoid
HS1L Interlock Switches with Solenoid 3000N locking strength (largest in class)! * Suitable for large and heavy doors. Same actuator as HS1E (actuator retention force 3000N) Six contacts in a compact housing
More informationSFS-UFS Single Foot Switches
SFS-UFS Single Foot Switches Technopolymer housing, shock proof Protection degree IP53 or IP65 13 contact blocks available Various auxiliary devices available UFS Series SFS Series Options & Ordering Codes
More informationSSX 19 PIN REVERSE SERIES
SSX 19 PIN REVERSE SERIES The SYNTAX SSX series, designed for professional lighting applications and perfectly compatible with standard Socapex 419 series, is extremely robust being made of thick wall
More informationATX PRE Series 125 Amp Plugs and Sockets Increased Safety
ATX PRE Series 125 Amp s and Sockets Applications s and sockets are used with stationary or portable electrically operated devices such as: Welding devices Lighting systems Conveyors Heaters Motor generator
More informationP17 Tempra. and Hypra. Plugs and. Sockets PRODUCTS AND SYSTEMS FOR ELECTRICAL INSTALLATIONS AND INFORMATION NETWORKS. P17 Tempra. plugs and.
PRODUCTS AND SYSTEMS FOR ELECTRICAL INSTALLATIONS AND INFORMATION NETWORKS P17 Tempra plugs and sockets P. 344 Surface mounting sockets Hypra Prisinter and Hypra plugs and sockets P. 345 Prisinter panel
More informationPRE Series 125 Amp Plugs and Sockets Increased Safety
s and Receptacles ATEX/IECEx/NBR IEC Ex e Zone 1 Rated s and Receptacles PRE Series 125 Amp s and Sockets - IK10 Applications s and sockets are used with stationary or portable electrically operated devices
More informationB6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data
B6, B7, BC6, BC7, TBC7 - and 4-pole mini contactors VB6, VB7, VBC6, VBC7 - and 4-pole mini reversing contactors Main pole Utilization characteristics according to IEC Standards IEC/EN 60947-1, IEC/EN 60947-4-1
More informationHS5D Miniature Interlock Switches
Head removal detection for safer performance. Head removal detection function turns OFF the main circuit (-) when the head of the is removed. The is the same size as contact interlock switches (HS5B).
More informationAmphenol-Tuchel Electronics 44 Series
44 Series Amphenol-Tuchel Electronics 44 Series Cost-effective environmental sealing Amphenol Tuchel 44 series connectors offer cost-effective performance for applications requiring environmental sealing.
More informationHARTING. Interface Connectors. People Power Partnership
11 4 HARTING Interface Connectors People Power Partnership People Power Partnership Quality Connections Worldwide HARTING was founded in 1945 by the family that still owns the company. Today, HARTING employs
More informationPowermate Range pitch 7.00 Powermate Range pitch 7.00
Contents lug and socket connectors with leaf spring connection.2 lug and socket connectors with TO connection.6.1 lug and socket connectors with leaf spring connection STVS S Derating curve STVS SB Socket
More informationAF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals
Technical Datasheet 1SBC101404D0201 24/03/11-30-10-.. / Z-30-10-.. 3-pole Contactors AC / DC Operated - with Screw Terminals (Z) contactors are used for controlling power circuits up to 690 V AC and 220
More informationPower distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly
NH fuse-switch disconnectors, size 000 Version -pole, cable outlet at the top/bottom For the use of fuse inserts to EN 60 - Technical specifications to IEC/EN 60 947-, see chapter -5, page 6 see chapter
More informationContents Technical characteristics Han A Technical characteristics Han 3 A with HARAX Termination
Contents Page... 01.02 3 with HRX Termination... 01.04 3, 3 with HRX Termination... 01.05 4... 01.06 10... 01.07 16... 01.08 32... 01.09 01 Features Metal and plastic version available 3 hoods/housings
More information55 Series - Miniature General Purpose Relays 5-10 A
Series - Miniature General Purpose Relays -0 A - Plug-in or P.C.B. versions - AC or DC coils - Lockable test button and mechanical flag indicator as standard on and CO relays types - Sockets and accessories:
More information1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide
1ZSE 2750-102 en, Rev. 7 Transformer bushings, type GOB Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical
More informationShell material Insulator Contacts Sealing Temperature Mating Protection
Technical Data Shell material Machined components: die cast components: Shell plating: Cable entry: Copper-Zinc alloy (CuZn) Zinc (GD-Zn) Nickel (Ni) plated max. 10 mm Insulator Connector inserts: Polyamid
More information38999 Series III Composite Connectors
8D Series Composite 38999 Series III Composite Connectors The RoHS connector with the best performance in weight saving and corrosion resistance for MilAero applications. MIL-DTL-38999 Standard Versatility
More informationM3 Series Product. Class 0 - protection against electric shock relies upon basic insulation
Product Changeover circuit with rating 16A ong life snap action contacts mechanism Self-cleaning contact action Variety of actuators Screw, front screw or quick connect (faston) terminals dimensions according
More informationD X X - XX - XX - X X
CONSTRUCTION MATERIAL FINISH Shell Alluminium Alloy Cadmium Olive Drab over Electroless Nickle Electroless Nickle Insert Engineering Plastic Natural O-ring Silicone Rubber Natural Contact Retainer Beryllium
More informationContact gap 7 mm (norm >5.5 mm) ÿ IN ENCLOSURE. ÿ WITH CLUTCH DRIVE
Switch disconnectors A modular and flexible range Contact gap 7 mm (norm 5.5 mm) Reversible terminal feature ÿ IN ENCLOSURE - Degree of protection: up to IP 66 - For 25A to 100A size switches (see Ithe
More informationabout us In 2011, Switchcraft was acquired by HEICO Corporation and became part of their Electronic Technologies Group.
table of contents 2 about us 3 custom products circular connectors & cable assemblies 6 en2 0.53 [13mm] od - 2-7 contacts 10 micro-con-x 0.53 [13mm] od - 2-7 contacts 16 en3 0.71 [18mm] od - 2-18 contacts
More informationMore than safety. Product Overview. Automation
More than safety. Product Overview Automation Automation at a glance Ident Systems CIS3 CIS3A CIS3A -Mini Read system Read/write system Read system Read/write system Read system Read/write system Housing
More informationMSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3
Introducing the New WEG Series. The was developed according to IEC 60947-3 & UL508. The compact, reliable design of the allows the operator to safely disconnect power and isolate the circuit within the
More informationOiltight Switches & Pilot Devices
Oiltight Emergency Stop Stations Part Numbers: Emergency Stop Stations Description Contacts Plastic Bezel Metal Bezel Ø 40mm Pushlock Turn Reset 1NO-1NC HW1X-BV411-R* HW4X-BV411-R* 2NC HW1X-BV402-R* HW4X-BV402-R*
More informationAF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts
AF4... AF96 -pole contactors to 6 hp at 48 V AC AC / DC operated with N.O. N.C. auxiliary contacts Description AF4... AF96 contactors are mainly used for controlling -phase motors and power circuits up
More informationFISCHER ULTIMATE TM SERIES RUGGED COMPACT LIGHTWEIGHT KEY FEATURES
H CHAPTER PAGES FISCHER TM SERIES RUGGED COMPACT LIGHTWEIGHT KEY FEATURES IP68 to -0m / IP69 / Hermetic 60 EMC shielding High corrosion resistance 0,000 mating cycles H - FISCHER TM SERIES Table of contents
More informationApprovals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking
MainswitchRearmounting Partno. T0-2-1/V/SVB-SW Articleno. 045992 Front IP65 Deliveryprogramme Product range Switch-disconnectors Basic function Main switches Maintenance switches Manual override switches
More informationFulfilling your needs & Safe
MEETING CZEPJ Industrial plugs and sockets Fulfilling your needs & Safe Pavel Mony, product management Plug and socket What s on the cable Connecting building and equipment Socket Connector Inlet Plug
More information