1 Operating Instructions Heavy Duty Sieve Shaker "analysette 18"
2 Fritsch GmbH Laborgerätebau Industriestrasse 8 D Idar-Oberstein Phone: *6784/ 70-0 Fax: *6784/ info@fritsch.de Internet: Fritsch GmbH, Laborgerätebau has been certificated by the TÜV- Zertifizierungsgemeinschaft e.v. on June 24, An audit certificated the accordance of the Fritsch GmbH to the DIN EN ISO The enclosed declaration of conformity calls the directives which the analysette 18 corresponds to. This permitts us to mark the instrument with the CE-Sign. Instrument number and applies as of serial number 100 Edition 09/2003 Index 000
3 Table of contents page 1 General Information / Introduction Notes about Operating Instructions Explanations of the signs at the instrument and in the operating instructions Short Description of the Machine Applications Method of Operation Technical Data Operating Safety General Safety Instructions Operators Installing the unit Unpacking Assembly Removal and Replacement of Transportation Bolts Levelling Sieve Stacking Electrical connection Using the sieve shaker Sieve Stacking Controls Power Supply Unit Controls Mains Inlet Mains Switch Mains Connected Indicator Mains Power Indicator Power Supply Unit Removable Low Voltage Control Unit Mains Power Indicator Process Timer Start Button Run Indicator Stop Button Safety Key Lock Safety Instructions Cleaning Maintenance Fuse Replacement Motor Removal Spring Replacement Warranty General Advice...11 analysette 18
4 1 General Information / Introduction 1.1 Notes about Operating Instructions The copyright to these technical documents is the property of Fritsch GmbH, Manufacturers of Laboratory Instruments. These operating instructions are not to be reprinted or copied without the express approval of Fritsch GmbH. Please study these instructions carefully before operation. All operators must be familiar with the contents of the operating instructions. Please observe all notes concerning your safety. The sieve shaker was designed with the user's safety in mind, however inherent risks cannot be excluded. Follow the advices in these instructions to avoid risks to users. The symbols in the right hand margin highlight the risks described in the text. Symbols are also to be found on the instrument warning users of possible risks. Warning symbols are surrounded by a triangle. These operating instructions do not constitute a complete technical description. They describe only the details required for safe operation and maintenance for usage under normal conditions. analysette 18 page 1 Attention! observe operating instructions
5 1.2 Explanations of the signs at the instrument and in the operating instructions Attention! warning against danger spot observe operating instructions Attention! mains voltage Attention! risk of explosion Wear protective gloves! Wear ear protectors! Wear safety goggles! Do not step below lifted load! analysette 18 page 2
6 1.3 Short Description of the Machine Applications The analysette 18 is a heavy duty vibrating shaker designed to conduct sieve tests in conjunction with sieve stacks for particle sizing of various material samples. It is a heavy duty sieve shaker for separation and classification of grain fractions, which has analytical screens up to 400 mm or 16" in diameter. It is especially suitable for particle size analysis or for separation of coarse-grained material in large quantities. The movement of a rotary sieve is a three dimensional movement, which is why it is often employed whenever mechanical screening has the advantage over hand screening for reasons of cost, or because of the required reproducibility of the results Method of Operation By utilising two off-set vibratory motors, mounted directly onto a location plate, the analysette 18 induces both vertical and rotational movement of the sample. This produces the optimum action for effective and efficient sieving. The analysette 18 is a fixed amplitude shaker. An incremental timer provides a range of pre-set and repeatable sieve test run times. The analysette 18 is not recommended for any Wet Sieving operation. The analysette 18 is fully EMC and LVD compliant and complies with all relevant European directives. analysette 18 page 3
7 1.4 Technical Data Model Heavy Duty Sieve Shaker analysette 18 Dimensions and Weight Dimensions: 385 mm High (excluding rods) 1,135 mm High (775 mm rods fitted) 580 mm Square Weight: 92 kg (net) Operating Noise The noise level can be as high as approx. 60dB (A). The value fluctuates greatly depending on the numbers of sieves used and the material being sieved. Voltage and Power consumption Voltage: Frequency: 50 Hz/60 Hz 50 Hz/60 Hz Phase: Single Power conspt. 280VA 480 VA Transient over voltages according to over voltage category II allowed. Electrical Fuses (Live & Neutral) These are 1¼ inch long anti-surge ceramic fuses that protect the electrical components within the equipment. It is important that the recommended current rating is not exceeded (3.15 amperes for 230 volts, 5 amperes for 110 volts) and the fuse is replaced with the same type and size. If the fuse blows after replacement then a fault exists in the equipment. Class 1 (earthed) Motor Speed 1,500 per min at 50 Hz 1,500 per min at 50 Hz 1,800 per min at 60 Hz 1,800 per min at 60 Hz Process Time 5 to 60 minutes Fritschs policy is one of continuous development and we reserve the right to modify future models. analysette 18 page 4
8 2 Operating Safety 2.1 General Safety Instructions Read the operating instructions carefully before use. The instrument can only to be used for the purpose described in Chapter Short Description of the Instrument Use only original accessories and original spare parts. Failure to do so may call into question the performance of the instrument. Do not use damaged accessories. The operators must be familiar with the contents of the operating instructions. To this end, for example, the operating instructions must with the instrument. Do not remove labels. Protective devices must not be made unserviceable or removed. Unauthorized modification of the instrument or any part thereof will result in the loss of the conformity to European directives which is asserted by Fritsch and the warranty. Wear protective gloves! Grinding bowls may be very hot after grinding. Wear safety glasses Don t run the instrument several hours without cooling phases - Danger of overheating. The analysette 18 is not recommended for any Wet Sieving operation. Behaviour at all times must be such as to strictly preclude any accidents. Furthermore, the MAC values at place of work specified in the pertinent safety regulations must be adhered to. Where applicable, ventilation must be provided or the instrument must be operated under an exhaust hood. When oxidizable materials such as metals, organic materials, wood, coal, plastic, etc. are sieved, the risk of spontaneous ignition (dust explosion) exists whenever the fine particles exceed a specific percentage. While such materials are being sieved, it is therefore necessary to take special safety precautions (e.g. wet grinding) and the work must be supervised by a specialist. The instrument is not explosion-proof and is unsuitable to grind or sieve materials which are explosive, combustible or promote combustion. Do not allow the analysette 18 to run unsupervised. Due to the vibrations, under certain operating conditions, the machine may creep along the surface on which it is located or mounted. analysette 18 page 5 Attention! observe operating instructions wear protective gloves wear safety goggles! wear ear protectors! Attention! risk of explosion
9 2.2 Operators No one other than authorized persons should operate the instrument and it must be serviced and repaired by trained specialists. No one suffering from medical problems or under the influence of medications, drugs, alcohol or overtiredness should be permitted to operate the instrument. 3 Installing the unit 3.1 Unpacking The shaker should be set up according to the following procedure and the diagram opposite. The internal packing and the following list of items should be removed from the case and checked before the analysette 18 is removed : 1 off Instruction Manual. 2 off Lifting Eyebolts. 2 off Long Clamp Rods. 2 off Standard Clamp Rods. 2 off M12 Plated Lock Nuts. 2 off M12 Plated Plain Washers. 1 off Clamp Plate complete with Clamping Assemblies. 1 off Control Unit (complete unit with 2 safety keys) 1 off Short Control Cable. 1 off Long Control Cable. 1 off Mains Cable. 3 off 10 mm Diameter. Location Pins. 3 off 15 mm Diameter. Location Pins. Screw the two M12 eyebolts provided into the top location plate and using a suitable lifting device, lift the analysette 18 and packing case on to suitable blocks to access the underside and remove the two M12 transit bolts. Do not lift the analysette 18 by the location plate without the transportation bolts fitted. 3.2 Assembly Once removed, lift the analysette 18 from the packing case and position on a level, rigid and robust floor, suitable for the operation of the sieve shaker (placing the shaker on a level surface ensures an even distribution of the sample over the sieves and ensures machine stability). Take Care as the shaker weighs 92 Kg When the analysette 18 is placed in its operating position the lifting eyebolts and transportation bolts can be removed, see diagram below (Retain for future use). analysette 18 page 6
10 3.3 Removal and Replacement of Transportation Bolts Fit one M12 nut and washer provided onto each clamp rod selected for use, then screw the pair of clamp rods into the location plate and tighten the locknuts. Warning: Transportation bolts must be removed before operating machine. 3.4 Levelling Release the locknuts on the machine feet and adjust until the shaker is level, then retighten the locknuts. 3.5 Sieve Stacking The analysette 18 shaker accommodates up to the following number of sieves in a stack plus the required lid and receiver: Diameter 350 mm 400 mm 450 mm/18 inch Screw the appropriate location pins into position on the location plate for the sieve stack range selected. Use the 15 mm diameter pins for the metric (350, 400 & 450 mm) range of sieves and the 10 mm diameter pins for the imperial (18 in.) sieves. Place the receiver centrally between the location pins. Stack the required sieves on top of the receiver. Put the sample under test in the top sieve and fit the lid. 3.6 Electrical connection Ensure that the voltage and frequency on the Rating Label at the rear of the shaker correspond with the electrical mains supply. If there is any discrepancy, please consult your supplier or a qualified electrician. Do Not Connect to any other supply other than that stated on the nameplate Important - This equipment must be connected to mains earth The analysette 18 sieve shaker is provided with a detachable 2 metre long mains cable, incorporating an IEC moulded connector and plug suitable for connecting to the local mains supply. Certain models may be supplied with a fused plug. In the event of failure the fuse must be replaced with a fuse of identical rating. For starting up the sieve, the main switch on the front must be switched on. The timer should be in the "Off" position. The green standby indicator should be on. analysette 18 page 7
11 4 Using the sieve shaker 4.1 Sieve Stacking Align the locking assemblies in the two side lugs of the clamp plate with the round clamp rods. Slide the clamp plate down squarely onto the lid at the top of the sieve stack. Ensure that the clamping hand wheels at the top are loose and the locking assemblies are fully pushed down. There should be a 5 mm gap between the large plain washer and the face of the hand wheel. Place one hand on the top of the clamp plate and hold square while locking one side handle lever. Repeat for the opposite side handle lever. The side handle levers can be set vertically downwards by pressing on the RED button and pulling the handle outwards to release. Turn the handle to a safe, convenient angle downwards and release to engage the teeth. Screw the two clamping hand wheels down simultaneously to ensure the clamping plate is square. Continue until the hand wheels are tight against the internal stop. Hand tightness must be exerted so that the assembly does not loosen during vibration. The locking side handle levers and clamping hand wheels must be tightened sufficiently to ensure that the sieves and receiver are clamped securely during operation. Damage may occur if the shaker is allowed to operate with a loose clamping plate. 4.2 Controls Operators should be familiar with, and fully understand the controls and indicators before operating the machine Power Supply Unit Controls The power supply unit is mounted in the rear of the shaker base, the following controls and indicators are on this: Mains Inlet Mains inlet with integral line filter. Ensure the IEC connector on the mains lead is pushed fully into the inlet Mains Switch This controls the electrical supply to the equipment. The side marked I is On and the side marked O is Off Mains Connected Indicator This indicates electrical power is connected to the equipment, even though the Mains switch is in the OFF position. The l.e.d. is illuminated when the IEC connector is pushed fully into the inlet and power is switched on at the local outlet. If the l.e.d. fails to light with the local outlet switch in the ON position then a Fuse has blown or power is not present at the mains analysette 18 page 8
12 4.2.5 Mains Power Indicator The l.e.d. indicates that power has been switched ON at the Mains switch. The shaker will operate when the appropriate actions or settings are made on the low voltage control unit. 4.3 Power Supply Unit Removable Low Voltage Control Unit The control unit can be mounted on the front of the shaker base (use the short low voltage cable) or in some other suitable remote position ie. bench, desk or wall mounted, where connection is made using the three metre long low voltage cable, which should be positioned to avoid trapping or creating any safety hazards. Do not connect or disconnect the control unit while the Power is connected Mains Power Indicator The l.e.d. indicates that power has been switched ON at the Mains switch at the rear of the shaker Process Timer Sets the overall time of the sieving operation. It may be set for operating periods of 5 to 60 minutes in 5 minute increments, the setting is increased by rotating clockwise and decreased by rotating anticlockwise Start Button Operates the machine when all conditions are satisfied Run Indicator The l.e.d. indicates that the shaker is operating Stop Button Stops the shaker during operating mode. The shaker cannot be restarted until the Reset Alarm sounds after approximately 20 seconds Safety Key Lock Immobilises the shaker during loading or unloading sieves, the Safety Key Lock also isolates the Start button which prevents the shaker from being restarted Safety Instructions Take Care that there are no loose sieves on the shaker! Do not attempt to remove the sieves before the shaker has come to a halt Do not unscrew clamping hand wheels or side handle levers while shaker is in operation analysette 18 page 9
13 5 Cleaning The machine can be cleaned with a soft damp cloth using a solution of water and a mild liquid detergent. Do not use any solvents for cleaning Do not allow any liquids to seep into the machine. 6 Maintenance Before commencing maintenance work, disconnect the mains plug and secure the machine against being switched on again unintentionally. When maintenance work is being performed, this should be indicated with a warning sign. The Fritsch analysette 18 sieve shaker is maintenance free o- ther than keeping external surfaces clean. 6.1 Fuse Replacement Should a fuse require replacement this must be of the identical type and rating as the original. The rating of the fuse is marked on a label above the fuse. Switch off the mains supply at the switch at the rear of the shaker and remove the mains cable. Unscrew the central cap of the fuse holder with a suitable coin or screwdriver, extract the holder and the fuse together. Remove the blown fuse or fuses and place the new fuse in to the metal retaining spring within the cap. Fit the cap and fuse back in the holder and screw in fully. Do not over tighten All replacement parts must be ordered by quoting the shaker serial number and the correct part number. Part numbers can be obtained from our sales or technical department. 6.2 Motor Removal Disconnect the electrical supply from the machine. Remove the clamp rods and location pins. Refit and tighten the three M6 transportation bolts through the outermost location pin holes. Carefully turn the shaker over to access the motors from underneath. Disconnect the wiring from the motor (noting the colour/ terminal connection). The bolts holding the motors can now be removed, to release the motors. To reassemble the shaker, reverse the actions listed above insuring that the fixing bolts are tightened to a Torque of 7.5 Kg.m. analysette 18 page 10 Fehler! Verweisquelle konnte nicht gefunden werden. Attention! mains voltage
14 6.3 Spring Replacement If a problem develops on any of the spring assemblies it is recommended that the parts are replaced as a complete set of four. Follow sequence above in the Motor Removal section. Carefully turn the shaker back over. Loosen the four spring fastening screws on the location plate. Remove the Three M6 transportation bolts from the location pin holes. Lift the location plate off the shaker base. The spring assemblies can be removed by loosening the four spring fastening screws on the base. To reassemble the spring assemblies, reverse the actions listed at 2 to 6 above, and then follow the instructions in the Motor Removal section to rebuild the shaker. 7 Warranty The warranty card enclosed with this shipment must be returned to the supplier completely filled out in order for the warranty to take effect. Fritsch GmbH of Idar-Oberstein and our "Application technology laboratory" and/or our agent in your country will be glad to advise and aid you. In order to answer any questions you may have, we will require the serial number stamped on the nameplate. 8 General Advice Fritsch shakers are fully tested and factory checked before shipping to customers. No parts require lubrication or resetting unless disturbed. The sieve shaker has been constructed and factory tested to ensure correct operation when connected to the specified electricity supply indicated on the machines rating plate. Use of unapproved spares or any alteration to the machine would invalidate all warranties and compliance with European directives for 'CE' Marking. Fritsch does not accept any responsibility if the operating instructions contained in this manual are not strictly followed. Warning Note: The analysette 18 is not recommended for use with liquids. analysette 18 page 11
The Powermatic User Guide Test Sieve Shaker
The Powermatic User Guide Test Sieve Shaker ISSUE 04-02 Contents Description Page 1 Setting Up: 2-8 Unpacking 2 Assembly 3-4 Levelling 4 Electrical Connections 5 Sieve Stacking 6-8 Operating Instructions
More informationOperating Manual. Translation of the original FRITSCH HEAVY DUTY SIEVE SHAKER
Operating Manual Translation of the original FRITSCH HEAVY DUTY SIEVE SHAKER Fritsch GmbH Milling and Sizing Industriestrasse 8 D - 55743 Idar-Oberstein Phone: +49 (0)6784/ 70-0 Fax: +49 (0)6784/ 70-11
More informationThe EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents
The EFL 2000/1 & 2 User Guide Test Sieve Shaker ISSUE 04-02 Contents Description Page 1 Setting Up: 2-8 Unpacking 2 Assembly 3 Clamping Assembly 4 Electrical Connections 5 Sieve Stacking 6 8 Operating
More information3. Operating instructions: Minor 200
1. Technical specifications 3. Operating instructions: Minor 200 Copyright 2015 by Endecotts Ltd. 13 1. Setting up Technical specifications SIEVE SHAKER MODEL: Minor 200 General Information The Minor 200
More informationMeinzer II TM. Testing Sieve Shaker
Meinzer II TM Testing Sieve Shaker Operation & Set-up Manual Model: 18480100 CSC Scientific, Inc. 2799-C Merrilee Drive Fairfax, VA 22031 USA Telephone: (703) 876-4030 (800) 621-4778 Fax: 703-280-5142
More informationSieve Shaker 200mm/300mm - 8/12 inch SV003
Sieve Shaker 200mm/300mm - 8/12 inch SV003 CONTENTS Introduction Specification Installation Controls Operation Maintenance Spares and Accessories 1 Introduction The unique action of this Sieve Shaker (Fig
More informationUser s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation
User s Manual 701934 Power Supply Yokogawa Electric Corporation 2nd Edition Foreword Revisions Thank you for purchasing the 701934 Power Supply. This user's manual contains useful information about the
More information& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL
72-6850 & 72-6852 HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL Table of Contents Introduction 2 Specification 2 Safety 4 EMC 5 Installation 6 Connections 6 Operation 7 Maintenance and Repair 8 www.tenma.com
More informationINSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE
INSTRUCTION MANUAL FOR THE CLINICAL 50 CENTRIFUGE 82013-800 January 2006 INDEX PAGE 1. General Information... 2 1.1 Description... 2 1.2 Safety precautions to be observed before operating the centrifuge...
More informationInstallation, Operating and Maintenance Instructions Retractable Door / Art.-Nr.:
Installation, Operating and Maintenance Instructions Retractable Door 06.2008 / Art.-Nr.: 1 818 024 ENGLISH CONTENTS PAGE 1 SAFETY REQUIREMENTS 3 1.1 Symbols and key words used 3 1.2 Designated use 3 1.3
More informationInstallation, Operation and Maintenance Manual. EVC Controller (from February 2007)
Installation, Operation and Maintenance Manual (from February 2007) Publication 2698C (GB) 0207 1A 3319 8035B Donaldson reserve the right to alter design without notice. Freedom from patent restrictions
More information1200W INVERTER GENERATOR
1200W INVERTER GENERATOR MODEL NO: IG1200 PART NO: 8877070 OPERATION & MAINTENANCE INSTRUCTIONS LS0117 INTRODUCTION Thank you for purchasing this CLARKE 1200W Inverter Generator. Before attempting to use
More informationLastolite Lastolite Lumen8 F200 Lumen8 F400 Stored Energy Guide Number (m/100iso) Recycling Time (100%) Flash Duration Flash Power
Lastolite Lastolite Lumen8 F200 Lumen8 F400 Stored Energy 200 w/s 400 w/s Guide Number (m/100iso) 42 60 Recycling Time (100%) 0.3 ~ 0.9 sec 0.4 ~ 1.6 sec Flash Duration 1/700 ~ 1/1700 sec 1/700 ~ 1/1700
More informationLED Twister II. User manual UK Version 1.0
LED Twister II User manual 152.624UK Version 1.0 LED DUOPLEX: For indoor use only CAUTION! Please read this manual carefully before operating! Pay special attention to Sections 3 & 5 of this document.
More informationSwitching DC Power Supply
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Model 1693, 1694 Switching DC Power Supply INSTRUCTION MANUAL 1 Safety Summary
More informationCatalyser Introduction. 3. Hazard Information. 2. Area of Application. 3.1 Symbology
ENGLISCH Catalyser 2300-0001 1. Introduction We are pleased with your decision to purchase the Catalyser. Please read the following operating instructions carefully and observe the safety information they
More informationDrive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions
Drive Unit e-drive1 Installation instructions 04/2014 English translation of the original German installation instructions Contents Foreword... 3 Availability... 3 Structural features in the text... 3
More informationInstruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:
Check out what else you can get from Martindale: 17th Edition Testers Accessories Calibration Equipment Continuity Testers Electricians Kits Environmental Products Full Calibration & Repair Service Fuse
More informationNANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500
NANOPAC-300 & 500 Power Supply Instruction manual NANOPAC-300 & NANOPAC-500 Version 01C Feb 5th, 2014 1 Packing list NANOPAC-300 or 500-1x NANOPAC-300 Power Supply or NANOPAC-500-1x Power Cord - 1x Instruction
More informationOPERATING & MAINTENANCE INSTRUCTIONS
8 WETSTONE BENCH GRINDER OPERATING & MAINTENANCE INSTRUCTIONS 0805 Thank you for purchasing this Clarke Bench Grinder. Before attempting to operate this bench grinder please read this instruction manual
More informationBT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT
BT403 A Geno Technology, Inc. (USA) brand name BT-300 Power Supply Cat. No. BT403 1-800-628-7730 1-314-991-6034 info@btlabsystems.com WARNING... 3 SAFETY INFORMATION... 3 ENVIRONMENTAL CONDITIONS... 4
More informationPeristaltic Cased Tube Pumps
Peristaltic Cased Tube Pumps Operating Manual Verderflex Economy Version 1.0v-01/2014 Print No. 01 45, 500, 1500, 3000, 8000 Verderflex Economy 1.0v-01.2014 Version 1.0v-01/2014 Print-No. 01 Verderflex
More informationContents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01
PrintPRO Universal Contents Overview 1 01 02 03 Overview of your extraction system (front) Overview of your extraction system (back) Overview of the Control Panel Safety Instructions 2 01 Important safety
More informationAIR FILTER MODEL NO: AF1000 OPERATION & MAINTENANCE INSTRUCTIONS PART NO:
AIR FILTER MODEL NO: AF1000 PART NO: 6471160 OPERATION & MAINTENANCE INSTRUCTIONS 1208 INTRODUCTION Thank you for purchasing this Clarke Air Filter. Before you try to use this product, read this manual
More informationSBCNNS. Abrasive Blast Cabinet Assembly & Operating Instructions
SBCNNS Abrasive Blast Cabinet Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.
More informationVSM480. Instruction Manual VARIABLE SPEED MIXER. Read instructions before operating this tool.
VSM480 VARIABLE SPEED MIXER Instruction Manual Read instructions before operating this tool. Important Please read these operating and safety instructions carefully and completely. For your own safety,
More information6 x 10 Belt Disc Sander
6 x 10 Belt Disc Sander FOR HELP OR ADVISE ON THIS PRODUCT PLEASE CALL OUR CUSTOMER SERVICE HELP LINE : 01509 500400 THE MANUFACTURER RESERVES THE RIGHT TO ALTER THE DESIGN OR SPECIFICATION TO THIS PRODUCT
More informationDRAFT COPY, NOT FOR DISTRIBUTION
GENERAL INFORMATION This manual contains relevant information concerning the technical aspects of using the Mediheat MH900/12 Portable Fluid Bag Warmer, and should be read by all persons expected to operate
More informationELECTRIC CAR POLISHER
ELECTRIC CAR POLISHER MODEL NO: CP254 PART NO: 6462108 OPERATION & MAINTENANCE INSTRUCTIONS LS0610 INTRODUCTION Thank you for purchasing this CLARKE electric car polisher. Before attempting to use this
More informationDC POWER SUPPLY ALIMENTATION C.C.
DC POWER SUPPLY ALIMENTATION C.C. ISO-TECH IPS 303A 201-3424 ISO-TECH IPS 601A 201-3446 SAFETY TERMS AND SYMBOLS These terms may appear in this manual or on the product: WARNING. Warning statements identify
More informationECSS. Electric Chain Saw Chain Sharpener Assembly & Operating Instructions
ECSS Electric Chain Saw Chain Sharpener Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. This manual provides
More informationUser s Manual Power Supply. IM E 3rd Edition. Yokogawa Electric Corporation
User s Manual 700938 Power Supply Yokogawa Electric Corporation 3rd Edition Introduction Revisions Thank you for purchasing the 700938 Power Supply. This Instruction Manual contains useful information
More informationRental Industry Safety Tester Safe Check 5s
Rental Industry Safety Tester Safe Check 5s Feb 2006 2006 Clare Instruments Inc. Issue 2.0 Firmware Version : 1.2a Limited Warranty & Limitation of Liability Clare Instruments Inc, guarantees this product
More informationDeclaration of Conformity as per Directive 97/23/EC
Declaration of Conformity as per Directive 97/23/EC The manufacturer declares that:, 47906 Kempen, Germany PTFE-lined Rotary plug valves Series 23e, with packing with lever for 90 operation with worm gear
More informationContents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2
INSTRUCTION MANUAL Contents Introduction Inspection Notes on Safety Precautions i i ii vii Chapter 1 Overview 1 1.1 Product Overview 1 1.2 Names of Parts 2 Chapter 2 Specifications 5 2.1 Product Specifications
More informationORIGINAL INSTRUCTIONS
OPERATION & MAINTENANCE INSTRUCTIONS CBB200 Shown here BUFFER/POLISHER MODEL NO: CBB150, CBB200 PART NO: 6500485, 6500490 ORIGINAL INSTRUCTIONS LS0818 - ISS 1 INTRODUCTION Thank you for purchasing this
More informationInstructions for Fitting, Operating and Maintenance Canopy Door RE / (St.: )
EN Instructions for Fitting, Operating and Maintenance Canopy Door 1 818 012 RE / (St.: 12.2010) 12.2010 ENGLISH Contents 1 Safety Instructions... 3 1.1 Qualified persons... 3 1.2 Symbols and signal words
More informationDC Master 24/ A
USERS MANUAL DC Master 24/12 50-60A DC-DC converter MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com ENGLISH Copyright 2015
More informationOPERATION MANUAL OM-K
UltraSonic Polisher OPERATION MANUAL OM-K0517 001 1. P 2 2. P 3 3. P 4 4. P 6 5. P 7 6. P 8 7. P 9 8. P 9 9. P10 10. P11 11. P11 12. P12 13. P13 CONTENTS 1. CAUTIONS FOR HANDLING AND OPERATION P16 2. SPECIFICATIONS
More information1100W PORTABLE GENERATOR
1100W PORTABLE GENERATOR MODEL NO: G1200 PART NO: 8010110 OPERATION & MAINTENANCE INSTRUCTIONS LS0312 INTRODUCTION Thank you for purchasing this CLARKE 1100W Portable Generator. Before attempting to use
More informationBowl feeder WV401-1 / Translation of operating and installation instructions
Bowl feeder WV401-1 / 402-1 Translation of operating and installation instructions Copyright by Afag GmbH This operation instruction applies to: Bowl feeder WV401-1 Bowl feeder WV402-1 Type 230 V / 50
More information12v / 24v Diesel Transfer Pump Kit
Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate
More informationOperating and Installation Instructions Diaphragm Vacuum Pumps and Compressors
Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected
More informationRE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW
Page 1 of 5 RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & Features: Benefits: 0-10Vdc or 0-5Vdc control input Over temperature protection with auto reset Din-rail mounting Efficient electronic switching No
More information28W WORK LAMP Model: CTL28 Part No:
28W WORK LAMP Model: CTL28 Part No: 4002905 INSTRUCTION MANUAL GC0609 INTRODUCTION Thank you for purchasing this CLARKE 28W Work Lamp. Before attempting to use the product, it is essential that you read
More informationOperating & Maintenance Instructions Thermobend Elite Range
Operating & Maintenance Instructions Thermobend Elite Range Table of Contents 1. Setting Up... 2 1.1 Introduction... 2 1.2 Location & Assembly... 4 1.3 Electrical Supply & Connection... 5 1.4 Pneumatic
More informationPURE SINE WAVE DC TO AC POWER INVERTER
PURE SINE WAVE DC TO AC POWER INVERTER 60S-12A / 60S-24A 60S-12E / 60S-24E 100S-12A / 100S-24A 100S-12E / 100S-24E 150S-12A / 150S-24A 150S-12E / 150S-24E Instruction manual SINE WAVE INVERTER Please read
More informationEXHAUST HOODS HNPD, HNPA, HPPD, HFPD, HNCD, HNCA, HPCD, HFCD, HKCD, HNPDC. Installation, Operation and Maintenance Manual
EXHAUST HOODS HNPD, HNPA, HPPD, HFPD, HNCD, HNCA, HPCD, HFCD, HKCD, HNPDC Installation, Operation and Maintenance Manual VALID FROM 2016 Introduction Novameta exhaust hoods are designed to fulfill the
More informationTechnical Information Manual
Technical Information Manual Revision n. 4 18 June 2008 MOD. A3000NF 3-PHASE NOTCH FILTER MANUAL REV. 4 NPO: 00120/04:3000N.MUTx/04 CAEN will repair or replace any product within the guarantee period if
More informationInstruction Manual. Labnet Spectrafuge 16M Microcentrifuge
Instruction Manual Labnet Spectrafuge 16M Microcentrifuge Labnet International PO Box 841 Woodbridge, NJ 07095 Phone: 732 417-0700 Fax: 732 417-1750 email: labnet@labnetlink.com Safety Precautions NEVER
More informationTension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!
Tension Meter FT Series S C H M I D T c o n t r o l i n s t r u m e n t s Edition FT 03.E Model FT Instruction Manual Valid as of: 01.09.2011 Please keep the manual for future reference! Contents 1 Warranty
More information1 MECHANICAL FUEL METER
1 MECHANICAL FUEL METER USER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious
More information90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 1410 90W DC Power Supply User Manual Safety Summary The following safety precautions
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies
Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions contain
More informationDUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL
72-7570 DUAL 60V 20A POWER FLEX POWER SUPPLY INSTRUCTION MANUAL Table of Contents Specification 1 Safety 3 EMC 4 Installation 5 Connections 5 Operation 6 Maintenance 8 Specification General specifications
More informationELECTRIC LIFTING HOIST
ELECTRIC LIFTING HOIST COMPLIES TO AS 1418 STANDARDS KP1201 125/250KG KP1202 400/800KG ED 2 / JULY / 15 TYPE 2 1 Table of Contents 1 Know Your Product...2 Electric Lifting Hoist Safety Instructions...3
More informationabb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.
Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.12 Product Overview ABB's type-tested ring main unit (RMU) is an SF 6 insulated RMU utilising the latest developments
More informationOperating Instructions
Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Notes Regarding Safety...3 4 Intended Area of Application...4 5 Technical Data...5
More informationRENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev
Manual Part #: M-3022 Feeder AF371 Operations Rev. 3-16-04 1 RENA AF371 Feeder YOUR RENA AF371 IS DISTRIBUTED BY RENA SYSTEMS INC. SERVICE AND SUPPORT FOR THIS PRODUCT IS PROVIDED BY YOUR RENA DEALER.
More informationType Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies
Type 5282 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation Contents 1 Operating Instructions... 2 2 Authorized use...
More informationOPERATION INSTRUCTIONS
www.r-techwelding.co.uk Email: sales@r-techwelding.co.uk Tel: 01452 733933 Fax: 01452 733939 ProArc 175 INVERTER ARC WELDER OPERATION INSTRUCTIONS Version 2017-10 2 3 Thank you for selecting the R-Tech
More informationAUTOGARD SERIES 820 TORQUE LIMITER Installation and Maintenance Manual DB0009 Issue 11 21 Feb 2017 British Autogard Ltd 2 Wilkinson Rd., Love Lane Industrial Estate, Cirencester, Glos., GL7 1YT UK Tel.
More informationHeavy Duty Series (HDS) Installation and user guide
Heavy Duty Series (HDS) Installation and user guide HDS20-50 HDS20-100 (2x50 Watt transducers) (2x100 Watt transducers) www.shipsonic.com a brand of: delta-sistems BV Blokjesplaat 1 4465 BC Goes The Netherlands
More informationINSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.
INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS. Before installing and/or using this product, please check for any visual damage of the enclosure, power
More informationUsers Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery
MS5900 Users Manual Table of Contents Introduction Motor and Phase Rotation Indicator is a handheld, battery-operated instrument designed to detect the rotary field of three-phase systems and determine
More informationInstallation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z
Installation and operating instructions Solar charge controller MPPT 10 A / 20 A EN 1 Contents 1. About these instructions... 3 1.1 Applicability... 3 1.2 Users... 3 1.3 Description of symbols... 3 2.
More informationSERVICE MANUAL SECOH AIR PUMPS
SERVICE MANUAL SECOH AIR PUMPS (SHOWN AT EL SERIES) MODEL: SLL-20, 30, 40 & 50 EL-60, 80-15, 80-17 & 100 EL-120W, 150 & 200-0 - This manual is not meant to be included in the scope of delivery (for this
More informationBowl Feeder BF10 / BF15 Translation of operating and installation instructions
Bowl Feeder BF10 / BF15 Translation of operating and installation instructions Copyright by Afag GmbH This operation instruction applies to: Bowl feeder right 12 Bowl feeder left 12 Type Order number BF10
More informationHST -LS Interlocking device (Translation of Original Manual)
Installation and Operating Manual for Components HST -LS Interlocking device (Translation of Original Manual) HST-LS Ident.-No.: 10268 HST-LS Ident.-No.: 10269 HST-LS, pictured Ident-Nr. 10269 The image
More informationOPERATING INSTRUCTIONS
Emergency Cord Switch Type PRS Device identification No.: 91.054 033.001, /.101 and /.201 OPERATING INSTRUCTIONS 2 CE Sign and Conformity The device meets the requirements of the valid European and national
More informationInstruction manual Hand-filing machine DIPROFIL FPT/ER and FPV/ER. Order no.: and
Instruction manual Hand-filing machine DIPROFIL FPT/ER and FPV/ER Order no.: 0 005 204 and 0 005 208 1 List of contents 1 List of contents Page 02 2 Tips on using the manual Page 02 3 Safety instructions
More informationSafety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15
17 Elster GmbH Edition 1.17 Translation from the German 519 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas VG VG 15/1 Contents Solenoid valve for gas
More informationPIL0478 ISSUE 01/ 07/16
ISSUE 01/ 07/16 PIL0478 ZAFIR G9 CEILING FITTING PIL0478 ISSUE 01/ 07/16 PART C PART E PART 21 SELV 1 1.B 1 3.1 3.3 3.4 3.5 3.6, 3.8 3.10 3.12 3.14 3.16 3.17 3.18 3.19 3.19 ATTENTION! THE TABLE BELOW
More informationOperating instructions Rotary actuators M135 M140 M150 M180. June 2012 / / EN
Operating instructions Rotary actuators M135 M140 M150 M180 June 2012 / 118614 / EN General information General information Proof of amendment Copyright Subject to alterations Manufacturer Version Date
More informationALL POSITION VARIABLE SPEED TRAVEL CARRIAGE
ALL POSITION VARIABLE SPEED TRAVEL CARRIAGE MODEL GK-189-045 PARTS LIST & OPERATING INSTRUCTIONS Distributed by: Website: www.gullco.com GULLCO INTERNATIONAL LIMITED CANADA Phone: 905-953-4140 Fax: 905-953-4138
More informationInstallation, Operation & Maintenance Instructions 250 C Laboratory Fan Ovens Apex Range models AX30, AX60 & AX120
Installation, Operation & Maintenance Instructions 250 C Laboratory Fan Ovens Apex Range models AX30, AX60 & AX120 This manual is for the guidance of operators of the above Carbolite products and should
More informationType 6213 EV, 6281 EV
Type 6213 EV, 6281 EV 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies Operating Instructions Bedienungsanleitung Manuel d utilisation 1 OPERATING INSTRUCTIONS The operating instructions
More informationPro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.
Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate
More informationThese installation and maintenance instructions must be read in full and completely understood before the installation!
These installation and maintenance instructions must be read in full and completely understood before the installation! 1. General information on the installation and maintenance instructions These instructions
More informationCompact System NRGS 11-2 NRGS Original Installation Instructions English
Compact System NRGS 11-2 NRGS 16-2 EN English Original Installation Instructions 810366-05 1 Contents Important Notes Page Usage for the intended purpose...4 Safety note...4 LV (Low Voltage) Directive
More informationMMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS
www.r-techwelding.co.uk MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS 2 Thank you for selecting the R-Tech MMA160S Inverter Arc Welder. The MMA160S has many benefits over traditional Arc welders, including
More informationZone 1 Linear Range - Installation Guide
Zone 1 Linear Range - Installation Guide CML14ATEX3119 & IEC Ex CML15.0001 This installation guide provides instructions for installing SPARTAN series of explosion protected Zone 1 Linear luminaires. Text
More informationOperating Manual for FINE-SPRAY gun W 3/FZ-Duo
Operating Manual for FINE-SPRAY gun W 3/FZ-Duo Read this manual carefully before installing, operating or servicing this spray gun. Keep always handy for further use. 1 Introduction The FINE-SPRAY gun
More informationHOT AIR GUN MODEL No. CHG 1500B Part No
HOT AIR GUN MODEL No. CHG 1500B Part No. 3400751 OPERATING & MAINTENANCE INSTRUCTIONS 0201 Thank you for selecting this CLARKE Hot Air Gun, which is designed for DIY and professional use alike. Before
More informationSIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions
SIP Direct Drive Oil-Lube Air Compressors - Operating & Maintenance Instructions Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.
More informationCordless Rechargeable Saw Instructions for Use
Technical data Voltage: DC 10.8V Weight: 1.25Kg Stroke rate: 0-2100/min Stroke: 15mm Cutting capacity: max diameter in wood 80mm / in soft metal 7mm Charging time: Between 5.0-5.5 Hours Battery: 1.3Ah
More informationOPERATION & MAINTENANCE INSTRUCTIONS
AUTOMATIC BATTERY CHARGER / MAINTAINER MODEL NO: CBO9-6/12 PART NO: 6267020 OPERATION & MAINTENANCE INSTRUCTIONS LS0615 INTRODUCTION Thank you for purchasing this CLARKE product. Before attempting to use
More informationFlexible Arm Stand F 360. User Manual
User Manual To ensure proper use of this instrument as well as to avoid injury while operating instrument, understanding this manual completely before use is highly recommended. Flexible Arm Stand User
More informationUsers Manual. Phase Rotation Indicator
9040 Phase Rotation Indicator Users Manual PN 2438546 April 2005, Rev.2, 5/11 2005-2011 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are
More informationOPERATOR S MANUAL Please read all the information in this booklet before using the unit.
TECHNE UCAL400 + Calibrator OPERATOR S MANUAL Please read all the information in this booklet before using the unit. Unit Serial number: 4/02 Issue 1 TECHNE is a registered Trademark of Techne Incorporated.
More informationOPERATING INSTRUCTION
11/05 Form #271 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 OPERATING INSTRUCTION Visit us at www.testequipmentdepot.com MODEL 3132 ANALOG INSULATION-CONTINUITY TESTER
More informationService Instructions. Syntron Electromagnetic Feeder Model: F-010-B DF-010-B
Service Instructions Syntron Electromagnetic Feeder Model: F-010-B DF-010-B Service Manual Syntron Electromagnetic Feeder Models: F-010-B and DF-010-B Installation Operation Maintenance 1 Table of Contents
More informationPROFESSIONAL CORDLESS IMPACT SCREWDRIVER
PROFESSIONAL CORDLESS IMPACT SCREWDRIVER Model CIS00 Part No 4500625 OPERATING & MAINTENANCE INSTRUCTIONS GC0309 INTRODUCTION Thank you for purchasing this CLARKE Impact Screwdriver. Before attempting
More informationc-go 24V/6A 24V/8A 24V/12A
c-go 24V/6A 24V/8A 24V/12A Battery charger GB Instruction manual 1 Index 1. Product description... 2 2. Safety advices... 3 3. Quick start guide... 4 4. Operation... 4 5. Problem solving... 6 6. Specifications...
More informationUser s Manual Power Supply IM E. 5th Edition
User s Manual 700938 Power Supply 5th Edition Thank you for purchasing the 700938 Power Supply. This user s manual contains useful information about the instrument s functions and operating procedures
More informationOPERATION & MAINTENANCE INSTRUCTIONS
AUTOMATIC BATTERY CHARGER / MAINTAINER MODEL NO: CBO9-12 PART NO: 6267025 OPERATION & MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS LS0118 - ISS 3 INTRODUCTION Thank you for purchasing this CLARKE product.
More informationSPARK PLUG CLEANING KIT OPERATING MANUAL
SPARK PLUG CLEANING KIT OPERATING MANUAL Spark Plugs - Tools & Accessories P/N 01.20.002 Rev. 08/2015 Copyright Copyright 2015 MOTORTECH GmbH. All rights reserved. Distribution and reproduction of this
More informationPOWER FOR TOMORROW. Motive Power. Network Power. Chargers. Bloc Batteries. Accessories. Service
POWER FOR TOMORROW TODAY The Eternity Technologies range is built using only the highest quality and most efficient production processes at our state-of-the-art manufacturing centre in the UAE. It is this
More informationINSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT
CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER INSTRUCTION MANUAL 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT These instructions contain both information and warnings
More informationEJ212 Electric Jack 1 Ton (2,000 lbs) Assembly & Operating Instructions
EJ212 Electric Jack 1 Ton (2,000 lbs) Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.
More information