INSTRUCTIONS PARTS LIST For use with Plural Component Precision Mixing Systems.

Size: px
Start display at page:

Download "INSTRUCTIONS PARTS LIST For use with Plural Component Precision Mixing Systems."

Transcription

1 INSTRUCTIONS PARTS LIST This manual contains IMPORTANT WARNINGS AND INSTRUCTIONS READ AND RETAIN FOR REFERENCE Rev B Supersedes A PRO Pulse ELECTRONIC VOLUMETRIC FLOW METER For use with Plural Component Precision Mixing Systems psi (196 bar) FLOW METER MAXIMUM WORKING FLUID PRESSURE Part No , Series A Flow Meter with 0.1 cc per tooth fluid volume flow Part No , Series A Flow Meter with 0.4 cc per tooth fluid volume flow Part No , Series A Flow Meter Receiver Module NOTE: See the ACCESSORIES section to order Fiber Optic Cables and to order the Fluid Manifold. U.S. and Foreign Patents Pending ELECTRONIC VOLUMETRIC FLOW METER FLOW METER RECEIVER MODULE ÎÎÎ ÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎ ÎÎÎÎÎ ÎÎÎ 0172A 0173 GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN COPYRIGHT 1991 GRACO INC.

2

3 WARNINGS SERIOUS BODILY INJURY, EXPLOSION, FIRE, OR ELECTRIC SHOCK CAN OCCUR IF THE PRECAUTIONS BELOW ARE NOT FOLLOWED. ELECTRICAL EQUIPMENT SHALL ONLY BE INSTALLED, OPERATED, AND SERVICED BY TRAINED, QUALIFIED PERSONNEL WHO SHALL BE FULLY CONVERSANT WITH THE REQUIREMENTS STATED WITHIN THIS INSTRUCTION MANUAL. READ AND UNDERSTAND ALL INSTRUCTION MANUALS AND WARNING LABELS BEFORE OPERATING THE EQUIPMENT. FIRE. EXPLOSION, OR ELECTRIC SHOCK HAZARD All parts of the fluid system must be properly grounded to reduce the risk of static electricity discharge. Sparks can ignite fumes from solvents and the fluid being dispensed, dust particles and other flammable substances, whether you are spraying indoors or outdoors, and can cause a fire or explosion and serious bodily injury and property damage. If you experience any static sparking or feel even a slight shock, STOP SPRAYING IMMEDIATELY. Check the entire system for proper grounding. DO NOT use the system again until the problem has been identified and corrected. This meter is designed to be used in a Class I, Group D hazardous environment. To reduce the risk of fire, explosion, or electric shock, IT IS ESSENTIAL THAT: 1. The meter s electrical chassis is properly grounded by mounting it on a grounded metal surface. Check the electrical grounding as instructed on page Water or other liquids are not spilled on the electrical chassis. 3. The air line to the electrical chassis is turned OFF and the pressure is relieved by following the Pressure Relief Procedure, below, before servicing or flushing the meter. 4. Follow the material suppliers Material Specification Data Sheets whenever flushing or servicing this meter. EQUIPMENT MISUSE HAZARD General Safety Any misuse of this equipment such as over-pressurizing the meter, using incompatible chemicals and fluids, modifying parts, or using worn or damaged parts, can cause equipment to rupture or malfunction, and can result in serious bodily injury, electric shock, fire, explosion, or property damage. ALWAYS follow the Pressure Relief Procedure, at right before removing or servicing the meter or any other part of the spray system. NEVER alter or modify any electrical components or circuits as this could cause a fire or explosion. Repair or replace worn or damaged parts immediately. Use only Graco replacement parts. System Pressure The meter has a maximum working fluid pressure of 2800 psi (196 bar). Never exceed the maximum working pressure of the meter or any other component or accessory used in the system. Fluid Compatibility BE SURE all fluids and solvents used are chemically compatible with the Wetted Parts shown in the TECH- NICAL DATA. Check the material data sheet or the fluid manufacturer s literature to see if the fluid is compatible with the meter s wetted parts. Pressure Relief Procedure To reduce the risk of serious bodily injury, including splashing in the eyes or on the skin, or injury from moving parts, fire, explosion, or electric shock, always follow this procedure when shutting off the system, when checking or servicing any part of the spray system, and whenever you stop operation. 1. Turn off the air supply to the meter. 2. Allow air to exhaust out of the exhaust port. 3. Turn off the fluid supply to the meter. 4. Shut off all electrical power to the fluid system or air system. 5. Follow the Pressure Relief Procedure for your fluid system dispensing device. IMPORTANT United States Government safety standards have been adopted under the Occupational Safety and Health Act. These standards particularly the General Standards, Part 1910 and the Construction Standards, Part 1926 should be consulted.

4 CONTENTS Warnings PrecisionMix Description Installation Operation Maintenance Flow Meter Parts List Receiver Module Parts Drawing & List Accessories Dimension Drawing Technical Data Troubleshooting Chart Important Phone Numbers Back Cover Service Warranty Back Cover Flow Meter Parts Drawing PRECISIONMIX DESCRIPTION The PRO Pulse Volumetric Flow Meter is designed to be used with the Graco PrecisionMix plural component mixing system when it is necessary to install the flow meter and dispensing system in a hazardous environment. The standard Graco PrecisionMix can be used to blend all popular two-component epoxy or polyurethane paints containing non-abrasive filler. For information on handling abrasive fluids, contact your Graco representative. The PrecisionMix is not intended for use with quick-setting paints (those with a pot life of less than 30 minutes). The system can be installed to mix components supplied from pressure vessels, from feed pumps transferring the fluids from their original containers, or from a central paint recirculating line. The standard PrecisionMix is designed to operate a single conventional spray gun in an air spray or airassisted airless spray system. To modify the unit to operate two guns, contact your Graco representative. Refer to the PrecisionMix Instruction Manual, Graco Form No , for more information on the PrecisionMix.

5 TYPICAL INSTALLATION M L G A B 2 C D E NON-HAZARDOUS AREA HAZARDOUS AREA H F N A B 1 C D E J P K KEY A Air Supply Line B Bleed-Type Air Supply Line Shut-off Valve (required) C Air Line Filter D Air Line Lubricator E Air Line Regulator F Pump G Fiber Optic Cable H Flow Meter J Fluid Supply Line K Fluid Supply L Receiver Module M Control Cabinet N Pump Grounding Wire (required) P Fluid Manifold WARNING To help reduce the risk of serious bodily injury, including splashing in the eyes or on the skin, the bleed-type air shut-off valve (B 1 ) MUST be installed in the system to relieve air trapped between this valve and the pump after the air is shut off. Trapped air can cause the pump to cycle unexpectedly. Locate the valve close to the pump. Fig 1 The PRO Pulse Volumetric Flow Meter is designed to detect the pulses induced on a magnetic sensor each time a gear tooth passes by the sensor. A specific volume of fluid flows through the meter with each gear tooth rotation. See the front cover for the specific fluid volume flow for your meter. See page 4 for a description of Graco PrecisionMix plural component mixing system. Installing the System The Typical Installation shown above is only a guide for selecting and installing the flow meter. The particular type and size system for your application must be custom designed for your needs. For assistance in designing a system, contact your Graco representative. Install the air line accessories in the order shown in the Typical Installation, using adapters as necessary The Receiver Module (M) mounts into a 19 in. (483 mm) Schroff, Rital, or equivalent enclosure. Mount the backplane circuit board to the back mounting bracket as shown in Fig 3, page 6. Slide the receiver module into the enclosure to mate connectors and secure to the front mounting brackets as shown in Fig 3. Have a qualified electrician install the Flow Meter as shown in Figs 2 to 5, pages 6 and 7. Connect the air line to the Flow Meter by pressing the front ferrule (D) and back ferrule (C) onto the tubing (A). Press the assembly into the fitting (E) and tighten the nut (A). See Fig 2. Connect the fiber optic cables by pressing the front ferrule (L) and back ferrule (K) onto the cable (G). See Figs 2 and 3. The maximum fiber optic cable length is 100 ft (30.5 m) with two splices. See ACCESSORIES to order cables.

6 INSTALLATION KEY A Tubing, 1/4 OD B Nut, nylon C Ferrule, back, nylon D Ferrule, front, nylon E Air Inlet Fitting F Meter G Fiber Optic Cables H Fluid Manifold J Nut, aluminum K Ferrule, back, aluminum L Ferrule, front, aluminum J K L F E Fiber Optic Sender 1 Fiber Optic Sender 2 Flow Indicator Light (Green) Power Indicator Light (Yellow) Fig 2 G A B C D H 0175A KEY A Back-plane Circuit Board B Fiber Optic Cables C Screw D Receiver Module E Control Cabinet A E From Precision Mix to TB-1 B ÎÎ ÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎ ÎÎÎ C Fiber Optic Transmitting Indicator Lights (Red) D Fig 3 Power Indicator Light (Red) 0176

7 INSTALLATION GNDS and +24VDC Connected Internally To Plural Component Mixing System EXTERNAL WIRING CONNECTION OF BACK-PLANE CIRCUIT BOARD For Remote Monitoring Spares Fig Descriptions of External Wiring Connections for Back-plane Circuit Board PIN DESCRIPTION PIN DESCRIPTION TBI-1 TBI-2 TBI-3 TBI-4 TBI-5 TBI-6 TBI-7 TBI-8 TBI-9 TBI-10 GND, DC retrun for +24 VDC GND, DC return for +24 VDC +24 VDC, 300mA minimum +24 VDC, 300mA minimum A1 Out, Part A Channel 1, +22 VDC (high), Open (low) A2 Out, Part A Channel 2, +22 VDC (high), Open (low) B1 Out, Part B Channel 1, +22 VDC (high), Open (low) B2 Out, Part B Channel 2, +22 VDC (high), Open (low) OPTO +25 VDC Max, +5 to +25 VDC Supply for OPTO Isolator Outputs OPTO A1 Out, Part A Channel 1, Optically Isolated Voltage (high) TBI-9 Supply, Voltage (low) 0 VDC (thru 2.43 Resistor) TBI-12 TBI-13 TBI-14 TBI-15 TBI-16 TBI-17 TBI-18 TBI-19 TBI-20 OPTO B1 Out, Part B Channel 1, Optically Isolated Voltage (high) TBI-9 Supply, Voltage (low) 0 VDC (thru 2.43 Resistor) OPTO B2 Out, Part B Channel 2, Optically Isolated Voltage (high) TBI-9 Supply, Voltage (low) 0 VDC (thru 2.43 Resistor) OPTO GND, +5 to +25 VDC DC Return for OPTO Isolator Outputs (Note: DC return is not electrically connected to TBI-1 or TBI-2 unless externally jumpered by customer.) Spare, No Connection Spare, No Connection Spare, No Connection Spare, No Connection Spare, No Connection Spare, No Connection TBI-11 OPTO A2 Out, Part A Channel 2, Optically Isolated Voltage (high) TBI-9 Supply, Voltage (low) 0 VDC (thru 2.43 Resistor)

8 INSTALLATION FIBER OPTIC CABLE HOOK-UP DIAGRAM Back-plane Wiring Diagram TB1 In a typical PrecisionMix System, there will be two Flow Meters, which are represented here by the letters A and B. Each Flow Meter will have two fiber optic cables, which are represented by the numbers 1 and 2. The Flow Meter is the Sender of the fiber optic signal (see Fig 2). The Receiver Module is the Receiver of the fiber optic signal. On the front panel of the Receiver Module, there are two sets of lights (set A1, A2 and set B1, B2), one set for each Flow Meter. See Fig 3. If lights (L.E.D.) A1 and A2 are on, the fluid is flowing through Flow Meter A and its signal is being properly received at the Receiver Module. If lights B1 and B2 are on, the fluid is flowing through Flow Meter B and its signal is being properly received at the Receiver Module. FIBER OPTIC CABLES FROM FLOW METER A FIBER OPTIC CABLES FROM FLOW METER B A2 F.O.* Receiver A1 F.O. Receiver B2 F.O. Receiver B1 F.O. Receiver *F.O. Fiber Optic Fig 5 Fiber Optic Cable Connectors Spares 0177 Check the Electrical Grounding WARNING Proper electrical grounding of your system is essential when used with flammable or combustible liquids. For your safety, read the warning section, FIRE, EXPLOSION, OR ELECTRIC SHOCK HAZARD, on page 3. Electrical Chassis Grounded Mounting Surface When using flammable or combustible liquids, ground the flow meter by mounting it on a grounded metal surface. Have a qualified electrician check the electrical grounding continuity between the flow meter electrical chassis and a true earth ground as shown in Fig 6. If the resistance is greater than 25 ohms, check the mounting or add a ground strap to the chassis. Digital Voltage Meter Water-base System Note: When electrostatically spraying water-base fluids, with flashpoints above 140 F (60 C) and less than 20% (by weight) organic solvents concentration, the entire fluid supply must be isolated from ground to maintain voltage at the spray device. Fig 6 True Earth Ground 0179A See the Water-base System Warnings on page 3 and Graco Water-base System Instruction Manual for proper installation of a water-base system.

9 OPERATION Operating Checklist Check the following list daily, before starting to operate the system, to help ensure you of safe, efficient operation. 1. Be sure all operators are properly trained and qualified to safely operate your system. 2. Be sure all operators are trained how to properly and completely relieve system pressure according to the Pressure Relief Procedure, at right. 3. Be sure the system is thoroughly grounded. See FIRE, EXPLOSION, OR ELECTRIC SHOCK HAZARD, page 3, and Check the Electrical Grounding, page Be sure the operator and all persons entering the installation site are properly grounded by wearing shoes with conductive soles or personal grounding straps. 5. Be sure ventilation fans are operating properly. WARNING To avoid a chemical reaction, which could lead to serious injury and equipment and property damage, BE SURE all fluids and solvents used are chemically compatible with the Wetted Parts shown in the TECHNICAL DATA. Check the material data sheet or the fluid manufacturer s literature to see if the fluid is compatible with the meter s wetted parts. WARNING Pressure Relief Procedure To reduce the risk of serious bodily injury, including splashing in the eyes or on the skin, or injury from moving parts, fire, explosion, or electric shock, always follow this procedure when shutting off the system, when checking or servicing any part of the spray system, and whenever you stop operation. 1. Turn off the air supply to the meter. 2. Allow air to exhaust out of the exhaust port. 3. Turn off the fluid supply to the meter. 4. Shut off all electrical power to the fluid system or air system. 5. Follow the Pressure Relief Procedure for your fluid system dispensing device. Operation Operate the flow meter between 20 and 50 psi (1.4 and 3.5 bar) air inlet pressure. Check to see that both the proper corresponding Flow Meter and Receiver Module indicator lights are on when the fluid is flowing. See the PrecisionMix Instruction Manual to operate the PrecisionMix system. MAINTENANCE WARNING Before checking, cleaning, or servicing the meter, ALWAYS follow the Pressure Relief Procedure, above, to help reduce the risk of serious bodily injury, including splashing in the eyes or on the skin, or injury from moving parts, fire, explosion, or electric shock. CAUTION DO NOT immerse the meter in solvent. Solvent could damage the meter s electrical components. 1. Clean the fluid and air line filters daily. 2. Clean the outside of the meter with a soft cloth dampened in a compatible solvent as needed. Flushing the Meter 1. Follow the Pressure Relief Procedure, above. 2. Connect the fluid line to the solvent supply unit. 3. Flush the meter until it is clean. 4. Follow the Pressure Relief Procedure, then disconnect the fluid line from the solvent supply unit. 5. Reconnect the fluid line to the fluid (paint) supply. 6. Turn on the fluid supply. 7. Operate until the meter and fluid line are free of solvent. 3. Flush the fluid supply line and meter fluid reservoir daily with a compatible solvent as instructed at right.

10 TROUBLESHOOTING CHART WARNING Installing and servicing this equipment requires access to parts that may cause electric shock or other serious bodily injury if the work is not performed properly. DO NOT install or service this equipment unless you are trained and qualified. Before checking, adjusting, cleaning or servicing any part of the meter, ALWAYS follow the Pressure Relief Procedure on page 9 to help reduce the risk of serious bodily injury, including splashing in the eyes or on the skin, or injury from moving parts, fire, explosion, or electric shock. PROBLEM CAUSE SOLUTION No power to flow meter; yellow LED is off Gears are not moving; green LED is off Receiver module not receiving signal; red LED is off 1. Insufficient air supply 2. Turbine alternator not working 3. Faulty turbine alternator 4. Excess moisture in air lines 5. Turbine not connect to PC board 6. Top PC board not connected to bottom PC board 7. Alternator shorted to chassis 1. Dried paint/fluid in gear track 2. Worn gears 1. Poor fiber optic cable connection 2. Damaged fiber optic cable 1. Adjust air regulator. 2. Check for dirt or moisture in turbine. 3. Be sure plug is in place on back of turbine alternator housing. Remove and test alternator. 4. Use air filter-moisture separator 5. Connect 3-pin connector to square pins. 6. Tighten bolts to compress gasket to in. 7. Check that insulating pad is in place. Replace pad if necessary. 1. Flush fluid section of meter as instructed in MAINTENANCE. 2. Replace faulty gears. 1. Check connection to ensure it is tight and free of contaminates. 2. Replace fiber optic cable.

11 SERVICE WARNING Installing and servicing this equipment requires access to parts that may cause electric shock or other serious bodily injury if the work is not performed properly. DO NOT install or service this equipment unless you are trained and qualified. Before checking, adjusting, cleaning or servicing any part of the meter, ALWAYS follow the Pressure Relief Procedure on page 9 to help reduce the risk of serious bodily injury, including splashing in the eyes or on the skin, or injury from moving parts, fire, explosion, or electric shock. NOTE: Check all possible remedies in the TROUBLESHOOTING CHART before dissassembling the meter. Follow the Pressure Relief Procedure and flush the meter as described on page 9. Disconnect the fiber optic cable(s) (G) from the electronic module (B). See Fig Carefully pull the alternator (14) away from the top housing. 4. Using an ohmmeter, test the coil in the turbine alternator. Measure the resistance between the two outer terminals of the 3-pin connector (J). The resistance should be 3 to 5 ohms. If the reading varies from this value, replace the alternator (14). 5. Lubricate the alternator o-ring (14a) seal with petroleum jelly. 6. Insert the alternator (14) into the top chassis (13). 7. Connect the 3-pin connector (J) to the 3 square pins (H) in the top chassis (13). 8. Check to see that the gasket (5) is not damaged. If damaged, replace the gasket. 9. Snap top and bottom chassis connector together. 10. Install and tighten the chassis screws (4) until the gasket (5) is compressed to inches. Disconnect the air hose fitting and remove the air hose from the meter. Disconnect both fluid hose fittings and remove the fluid hose from the meter. Remove the four screws (A) to separate the gear housing (F) from the adaptor plate (D) or mounting plate. CAUTION NEVER remove the electronic module (B) from the top gear housing (E). The electronic module is calibrated to the gear housing assembly and will not function properly if removed Torque to 7.5 ft-lb (10 N m) A 14a H G B 14 J F 5 E C* D Fig A 12 Replacing the Turbine Alternator 1. Unscrew the top chassis (13) from the bottom chassis (12). See Fig Disconnect the 3-pin connector (J) from the square pins (H). Fig A

12 SERVICE Replacing Worn Bearings A repair kit is available to service the bearings. An asterisk after the description or reference letter indicates a part included with the repair kit. See page 13 to order the proper kit for your meter model. CAUTION This is a close-tolerance device. It will be damaged if forced apart during disassembly. 1. Loosen the four screws (N). See Fig 9. Leave about two threads connected. 2. The two halves of the gear housing are pegged together and will be difficult to separate. The pegs are part of the top gear housing (E). Hold the housing and tap the screws one at a time in a consistent sequence, and eventually the two halves will come apart. 3. Before removing the gears (L), note which peg the gear is being removed from. The gears must be installed on the same peg they were removed from. 3. Replace the four shims (K*) and the large o-ring (M*) with the kit parts. See Fig Install the gears on their proper pegs. 5. Press the gear housings together and secure them with the four screws (N). Torque the screws to 7.5 ftlbs (10 N m). 6. Install the meter back onto the adapter plate. NOTE: When installing the screws (A), replace the meter s two o-rings (C*) with o-rings from the kit. Torque screws to 7.5 ft-lbs (10 N m). See Fig 7. Kit has two sets of o-rings. Use the o-rings that match the o-rings you are replacing and discard the others. CAUTION NEVER immerse a meter in solvent for cleaning. Doing so will damage the electronics. CAUTION ALWAYS reinstall the gears on the peg they were removed from to ensure proper calibration with the electronic module. 4. Support a gear on its sides and position the bearing tool* on the gear as shown in Fig 10. Make sure the gear has sufficient clearance in the center to press out the bearings and washers. 5. Press the bearing tool with an arbor press or tap it with a soft hammer until the bearings and washers are removed. Repeat with the other gear. E K* L K* M* To install the kit parts and assemble the gear housing: 1. Place a gear on a flat surface. Position the bearings*, spacers*, and washers* and the bearing tool* as shown in Fig Press the bearing tool with an arbor press or tap it with a soft hammer until bearings, spacers, and washers are installed into the gear. Repeat with the other gear. Fig 9 N Torque to 7.5 ft-lb (10 N m) 01012A

13 SERVICE Removing Bearings Installing Bearings Bearing Tool* Bearing Tool* Inner Spacer* Gear ÉÉ ÉÉ ÉÉ ÉÉ Bearing Assembly Support *Outer Spacer Gear ÉÉ ÉÉ ÉÉ ÉÉ Top Bearing* Bottom Bearing* Flat Surface Fig Fig BEARING REPAIR KIT Bearing Repair Kit For Meter Model , with 0.1 cc per tooth fluid volume flow Bearing Repair Kit For Meter Model , with 0.4 cc per tooth fluid volume flow Bearing Repair Kit For Meter Model , with 1.6 cc per tooth fluid volume flow Not Included with Kit 0967

14 FLOW METER PARTS DRAWING a a A

15 FLOW METER PARTS LIST Part No , Series A 0.1 cc/tooth fluid volume flow Part No , Series A 0.4 cc/tooth fluid volume flow REF NO. PART NO. DESCRIPTION QTY 1 GEAR HOUSING ASSY; See ordering information at right FLAME ARRESTOR FITTING, air inlet; 1/4 tube SCREW, top mounting; M4 x 0.7 x 30 mm long GASKET, adhesive backing BALL SPRING WASHER, flow FITTING, valve BODY RETAINER CHASSIS ASSY, bottom; Includes item 12a 1 12a PAD, insulating CHASSIS ASSY, top ALTERNATOR; Includes item 14a 1 14a O-RING, alternator; Viton NUT, tube fitting; 1/4 OD FERRULE, back; 1/4 OD FERRULE, front, 1/4 OD 2 To Order Gear Housing Assembly (item 1) To replace the Gear Housing Assembly, you must send the complete flow meter assembly back to your local Graco distributor. The flow meter needs to be recalibrated when a new gear housing is installed. HOW TO ORDER REPLACEMENT PARTS 1. To be sure you receive the correct replacement parts, kits or accessories, always give all of the information requested in the chart below. 2. Check the parts list to identify the correct part number; do not use the ref. no. when ordering. 3. Order all parts from your nearest Graco distributor. 6 digit Part Number Qty Part Description Viton is a registered trademark of the Du Pont Company. RECEIVER MODULE PARTS DRAWING & LIST ÎÎ ÎÎÎ ÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎ ÎÎÎ Part No , Series A Receiver Module REF NO. PART NO. DESCRIPTION QTY PANEL BOARD, back BOARD, receiver

16 ACCESSORIES Fiber Optic Cables Fiber Optic Cable Assembly For connection between receiver module and flow meter or between receiver module and bulkhead connector. PART NO. LENGTH ft (1.8 m) ft (5 m) ft (8 m) ft (11 m) ft (15 m) ft (23 m) ft (30.5 m) Fluid Manifold Contact your local Graco respresntative to order proper manifold Part No Part No Bleed-type Master Air Valve psi (21 bar) Maximum Working Pressure Relieves air trapped in the air line between the pump air inlet and this valve when closed. 1/2 npt 0183 Fiber Optic Cable Extender For connection between flow meter and bulkhead connector or between two bulkhead connectors. PART NO. LENGTH ft (1.8 m) ft (5 m) ft (8 m) ft (11 m) ft (15 m) ft (23 m) ft (30.5 m) Grounding Clamp and Wire ga, 25 ft (7.6 m) wire Bulkhead Connector For connection between two fiber optic cables. 0185

17 NOTES

18 FLOW METER DIMENSIONAL DRAWING Part No. Dim. A Dim. B Dim. C DIM. A in. (108 mm) 4.10 in. (104 mm) 4.44 in. (113 mm) in. (108 mm) 4.25 in. (108 mm) 4.50 in. (114 mm) DIM. B in. (108 mm) 4.77 in. (121 mm) 4.22 in. (107 mm) TECHNICAL DATA DIM. C 0182A Maximum Working Fluid Pressure psi (35 bar) Maximum Working Air Pressure psi (3.5 bar) Fluid Pressure Operating Range Air Pressure Operating Range. Air Inlet psi (0 35 bar) psi ( bar) 1/4 inch OD tube Maximum Fiber Optic Cable Length ft (30.5 m) with two splices Wetted Parts Carbon Steel, Nickel Chrome Plating, Stainless Steel, EPDM (ethylene propylene)

19 RECEIVER MODULE DIMENSIONAL DRAWING Technical Description Standardized Euroboard Plug-in Unit for a Modular 19 in. (482.6 mm) Rack System per DIN 41494, Part 5, ANSI/IEEEE 1101 Connector to DIN 41612, 1EC 603-2, Type C ÎÎÎ ÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎÎÎ ÎÎÎÎÎÎ ÎÎÎÎÎ ÎÎÎ 6.7 in in. ( mm mm) 5.1 in. (128.7 mm) 2.8 in. (71.12 mm) 0173

20 THE GRACO WARRANTY AND DISCLAIMERS WARRANTY Graco warrants all equipment manufactured by it and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use. As purchaser s sole remedy for breach of this warranty, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment proven defective, with the exception of defects in the internal power supply and alternator, which will be repaired or replaced for thirty-six months from the date of sale. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco s written recommendations. This warranty does not cover, and Graco shall not be liable for, any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility with Graco equipment of structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco. This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor and transportation. DISCLAIMERS AND LIMITATIONS THE TERMS OF THIS WARRANTY CONSTITUTE PURCHASER S SOLE AND EXCLUSIVE REMEDY AND ARE IN LIEU OF ANY OTHER WARRANTIES (EXPRESS OR IMPLIED), INCLUDING WARRANTY OF MERCHAN- TABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND OF ANY NON CONTRACTUAL LIABILITIES, INCLUDING PRODUCT LIABILITIES, BASED ON NEGLIGENCE OR STRICT LIABILITY. EVERY FORM OF LIABILITY FOR DIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES OR LOSS IS EXPRESSLY EX- CLUDED AND DENIED. IN NO CASE SHALL GRACO S LIABILITY EXCEED THE AMOUNT OF THE PUR- CHASE PRICE. ANY ACTION FOR BREACH OF WARRANTY MUST BE BROUGHT WITHIN TWO (2) YEARS OF THE DATE OF SALE. EQUIPMENT NOT COVERED BY GRACO WARRANTY GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, WITH RESPECT TO ACCESSORIES, EQUIPMENT, MATERIALS, OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motor, switches, hose, etc.) are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties. IMPORTANT PHONE NUMBERS TO PLACE AN ORDER, contact your Graco distributor, or call Graco: Toll Free FOR TECHNICAL ASSISTANCE, service repair information or answers about the application of Graco equipment, call: Toll Free Factory Branches: Atlanta, Chicago, Dallas, Detroit, Los Angeles, Mt. Arlington (N.J.) Subsidiary and Affiliate Companies: Canada; England; Switzerland; France; Germany; Hong Kong; Japan; Korea GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN PRINTED IN U.S.A /91 Revised 4/92

PRO ES Test Fixture, High Voltage Test Probe, & KV Meter

PRO ES Test Fixture, High Voltage Test Probe, & KV Meter INSTRUCTIONS PARTS LIST 308 217 This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE Rev. B Supersedes A PRO ES Test Fixture, High Voltage Test Probe, & KV Meter To Test

More information

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

INSTRUCTIONS PARTS LIST This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE INSTRUCTIONS PARTS LIST 308 493 This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE Rev. A Second Gun Hose Kit 100 psi (6.9 bar) Maximum Working Pressure These kits include

More information

Viscount I Hydraulic Motor and Displacement Pump

Viscount I Hydraulic Motor and Displacement Pump INSTRUCTIONS-PARTS LIST 308 674 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Rev. C Supersedes Rev. B Viscount I Hydraulic Motor and Displacement Pump

More information

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type INSTRUCTIONS-PARTS LIST 306 460 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Rev. E Supercedes D Detachable-type LUBRICATOR GUN 10,000 psi (700 bar)

More information

Spray Nozzle Adapters

Spray Nozzle Adapters INSTRUCTIONS-PARTS LIST 306 788 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. First choice when quality counts. Rev. G Supersedes Rev. F DIRECTIONAL

More information

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser INSTRUCTIONS-PARTS LIST 30 455 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Rev. C Supercedes B Hand-Operated Portable Grease Dispenser Buckshot Luber

More information

INSTRUCTIONS PARTS LIST

INSTRUCTIONS PARTS LIST INSTRUCTIONS PARTS LIST 30812 This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE See manual 308393 for complete gun washer warnings and instructions. Rev. B AIR SPRAY

More information

Pro Shot Grease Dispense Valve

Pro Shot Grease Dispense Valve Instructions Parts List Pro Shot Grease Dispense Valve 309032J For high pressure grease dispense. 8000 psi (55 MPa, 552 bar) Maximum Working Pressure Model No. 242055, Series B, 1/4 npt Fluid Inlet Model

More information

Air Control Kit INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

Air Control Kit INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 308 648 Rev. B Supersedes A HIGH VOLUME Air Control Kit 250 psi (.7 MPa, 7.2 bar)

More information

Stainless Steel Air Motor Conversion Kits

Stainless Steel Air Motor Conversion Kits Instructions Stainless Steel Air Motor Conversion Kits 096B Conversion Kit 650 For 00 Pumps Conversion Kit 65 For 590 Pumps Conversion Kit 65 For 50 Pumps Model 650 Model 65 Model 65 Graco Inc. P.O. Box

More information

Pressurized oil drain for collection of used lubricants and anti-freeze.

Pressurized oil drain for collection of used lubricants and anti-freeze. Instructions - Parts List 24-Gallon (90-Liter) Oil Ace 30864B Pressurized oil drain for collection of used lubricants and anti-freeze. Model 9577 Series A 8 psi (55 kpa,5 bar) Maximum Working Pressure

More information

INSTRUCTIONS-PARTS LIST

INSTRUCTIONS-PARTS LIST INSTRUCTIONS-PARTS LIST 308113K Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. Electronic Lubricant Valve, Metered or Unmetered Hi-Flow In-Line

More information

Stainless Steel Air Motor Conversion Kits

Stainless Steel Air Motor Conversion Kits Instructions Stainless Steel Air Motor Conversion Kits 096D Conversion Kit 650 For 00 Pumps Conversion Kit 65 For 590 Pumps Conversion Kit 65 For 50 Pumps Model 650 Model 65 Model 65 Installation Pressure

More information

Old Proportioning Pumps

Old Proportioning Pumps Repair - Parts Old Proportioning Pumps 311391F For proportioning pumps on Gusmer and Old Graco H-25 and H-XP2 Hydraulic Proportioners. Important Safety Instructions Read all warnings and instructions in

More information

Air Actuated Dispense Valve

Air Actuated Dispense Valve Instructions-Parts Air Actuated Dispense Valve 312782B To dispense plural component fluids and solvents. Part No. 15X303 High Pressure Dispense Valve 3000 psi (21 MPa, 210 bar) Maximum Fluid Working Pressure

More information

Precision Pulse Volumetric Fluid Flow Meter

Precision Pulse Volumetric Fluid Flow Meter INSTRUCTIONS PARTS LIST 308 314 This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE Rev. A Precision Pulse Volumetric Fluid Flow Meter Models PPM 3050, 3100, and 3550

More information

Air Control Kits INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

Air Control Kits INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 308 722 Rev. A HIGH VOLUME Air Control Kits 250 psi (.7 MPa, 7.2 bar) Maximum

More information

Pump/Manifold Kits. Instructions F ENG. To convert E-Flo 4-Ball Piston Pumps to a different size lower. For professional use only.

Pump/Manifold Kits. Instructions F ENG. To convert E-Flo 4-Ball Piston Pumps to a different size lower. For professional use only. Instructions Pump/Manifold Kits 311611F ENG To convert E-Flo 4-Ball Piston Pumps to a different size lower. For professional use only. See page 2 for a list of available kits. Important Safety Instructions

More information

Model PPM 200 Precision Pulse Volumetric Fluid Flow Meter

Model PPM 200 Precision Pulse Volumetric Fluid Flow Meter INSTRUCTIONS PARTS LIST 308 331 INSTRUCTIONS This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE Model PPM 200 Precision Pulse Volumetric Fluid Flow Meter Displays instantaneous

More information

Color Change Valve. Instructions Parts List K

Color Change Valve. Instructions Parts List K Instructions List Color Change Valve 0K For color changing or distribution of industrial paints and coatings or fluids. 00 psi (0. MPa, bar) Maximum Air Inlet Pressure 00 psi (. MPa, bar) Maximum Fluid

More information

Air Actuated Dispense Valve

Air Actuated Dispense Valve Instructions-Parts Air Actuated Dispense Valve 312782D EN To dispense plural component fluids and solvents. For professional use only. Part No. 15X303 High Pressure Dispense Valve 3000 psi (21 MPa, 207

More information

Fuel Meter. Instructions - Parts List. Contents B. Model , measures in gallons Model , measures in liters. For metering fuels.

Fuel Meter. Instructions - Parts List. Contents B. Model , measures in gallons Model , measures in liters. For metering fuels. Instructions - Parts List Fuel Meter 311309B For metering fuels. 80 psi (0.55 MPa, 5.5 bar) Maximum Working Pressure Model 260405, measures in gallons Model 260414, measures in liters Important Safety

More information

Model , Series A 9 in. (23 cm) roller frame with 45 angle and 12 in. reach 1/2 in. (13 mm) nap roller cover

Model , Series A 9 in. (23 cm) roller frame with 45 angle and 12 in. reach 1/2 in. (13 mm) nap roller cover Operating Instructions 309899 Rev. A This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. INSTRUCTIONS Manufactured by Model 246818, Series A 9 in. (23 cm) roller frame

More information

INSTRUCTIONS This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE

INSTRUCTIONS This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE INSTRUCTIONS 307 378 INSTRUCTIONS This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE Rev. H Supersedes G Model 600 Air Spray Gun 100 psi (7 bar) Maximum Working Fluid

More information

1 I t NOTE: PARTS LIST. Reassembly

1 I t NOTE: PARTS LIST. Reassembly 10. Remove the four tie rod locknuts (G). Model 210-107 may be turned upright for the remainder of the procedure, if desired. Models 217-022 and 217338 should remain on their side. Remove the four tie

More information

Cleaning System. Instructions/Parts A

Cleaning System. Instructions/Parts A Instructions/Parts Cleaning System 310623A 234533 For use with Multi-Orifice Linear Streaming Applicator (MOLSA) to apply automotive Liquid Applied Sound Deadener (LASD) materials. 100 psi (0.68 MPa, 6.8

More information

Texture Gun & Hopper B

Texture Gun & Hopper B Operation and Parts Texture Gun & Hopper 309584B For Water-Based Materials Only Model 245924 100 psi (7 bar, 0.7 MPa) Maximum Working Air Pressure 60 psi (4.1 bar, 0.41 MPa) Maximum Working Fluid Pressure

More information

ProMix Auto Color and Catalyst Change Kits

ProMix Auto Color and Catalyst Change Kits Installation - Parts ProMix Auto Color and Catalyst Change Kits 311396C EN For proportional mixing of plural component coatings. For professional use only. See page 2 for kit information. Important Safety

More information

Merkur Displacement Pump

Merkur Displacement Pump Repair/Parts Merkur Displacement Pump 32792G EN For use with high-performance finishing and coating pumps in hazardous and non-hazardous locations. For professional use only. Important Safety Instructions

More information

Motor Mounting Kits. Instructions J EN. 16C487 Motor Coupler Kit includes 2.25 in. (57.2 mm) key For NEMA 182/184 TC Frame ATEX Electric Motors

Motor Mounting Kits. Instructions J EN. 16C487 Motor Coupler Kit includes 2.25 in. (57.2 mm) key For NEMA 182/184 TC Frame ATEX Electric Motors Instructions Motor Mounting Kits 31160J EN To install electric motors on E-Flo 4-Ball Piston Pumps. For professional use only. (Kits do not include motors.) 16C487 Motor Coupler Kit includes 2.2 in. (7.2

More information

Pump Package Conversion Kits

Pump Package Conversion Kits Instructions - Parts Pump Package Conversion Kits A0B ENG To install an L00CM or L500CM Check-Mate Displacement Pump on an existing motor. For professional use only. Not for use in explosive atmospheres.

More information

Mechanical Pulse Meter

Mechanical Pulse Meter Instructions Parts List Mechanical Pulse Meter Part No. 215474 Measures in pints, quarts, and gallons 308847D Part No. 215475 Measures in liters For antifreeze or oil. Sends 10 pulses per quart (11 pulses

More information

Instructions-Parts 3A2801G. See page 2 for model part numbers, maximum fluid working pressure, and approvals.

Instructions-Parts 3A2801G. See page 2 for model part numbers, maximum fluid working pressure, and approvals. Instructions-Parts Mix Manifold Kit 3A2801G EN For at-the the-gun mixing of 2 component materials when used with a ProMix PD2K Proportioner. For professional use only. Important Safety Instructions Read

More information

Field Sensitive Magnetic Proximity Cycle Switch

Field Sensitive Magnetic Proximity Cycle Switch Instructions Field Sensitive Magnetic Proximity Cycle Switch 3A0884A EN Bulletin 15600 4-pin micro FSM proximity switch use with MX, MXP & MGO Valve sections. Dry contact, ceramic magnet proximity switch

More information

15H882 Slider Bearing Kit

15H882 Slider Bearing Kit Instructions 15H882 Slider Bearing Kit 311616D ENG To replace slider bearings on E-Flo 4-Ball Piston Pumps. For professional use only. Important Safety Instructions Read all warnings and instructions in

More information

Fast-Flo Air Motor 12.5 bar (1.25 MPa, 180 psi) Maximum Air Working Pressure

Fast-Flo Air Motor 12.5 bar (1.25 MPa, 180 psi) Maximum Air Working Pressure 03652 Instructions Parts List Fast-Flo Air Motor 12.5 bar (1.25 MPa, 180 psi) Maximum Air Working Pressure 307456S Model 215963, Series A 101.6 mm (4 in.) stroke NOTE: To replace Air Motor 215963, order

More information

Displacement Pump. Instructions C EN. Model psi (3.7 MPa, 37 bar) Maximum Working Pressure 12 gpm Flow Rate

Displacement Pump. Instructions C EN. Model psi (3.7 MPa, 37 bar) Maximum Working Pressure 12 gpm Flow Rate Instructions Displacement Pump 308486C EN For use with petroleum-based lubricants only. For professional use only. Model 237527 540 psi (3.7 MPa, 37 bar) Maximum Working Pressure 12 gpm Flow Rate Important

More information

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings - Instructions Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. 311082D Pressure Roller with 24-inch Fixed Extension - For application of architectural

More information

Model For petroleum products and other fluids compatible with aluminum and buna-n seals.

Model For petroleum products and other fluids compatible with aluminum and buna-n seals. Instructions - Parts List Piston Hand Pump 311308C Model 260407 For petroleum products and other fluids compatible with aluminum and buna-n seals. Model 260406 For herbicides and other chemicals or fluids

More information

Universal Hand Pump. Instructions D EN. - For transferring grease to Grease Jockey and G3 Systems - Part No Hand Operated - 35# Pump

Universal Hand Pump. Instructions D EN. - For transferring grease to Grease Jockey and G3 Systems - Part No Hand Operated - 35# Pump Instructions Universal Hand Pump 31758D EN - For transferring grease to Grease Jockey and G3 Systems - Part No. 47886 Hand Operated - 35# Pump 600 psi (4.13 MPa, 41.3 bar) Maximum Working Pressure 85 ml

More information

45:l Ratio King" Pump, Model SP

45:l Ratio King Pump, Model SP INSTRUCTIONS-PARTS LIST 0 308-04 This manual contains IMPORTANT WARNINGS AND INSTRUCTIONS READ AND RETAIN FOR REFERENCE GRACO Rev A SUPPLEMENTARY,NFORMATION 45:l Ratio King" Pump, Model SP 28-335 4050

More information

24G621 Agitator Speed Controller Accessory

24G621 Agitator Speed Controller Accessory Instructions-Parts 24G62 Agitator Speed Controller Accessory 3A35A ENG Accessory kit to control and automatically maintain the speed of an air-powered agitator. For professional use only. Important Safety

More information

Low Pressure Fluid Filters

Low Pressure Fluid Filters Instructions - Parts List Low Pressure Fluid Filters 311775D EN For filtering large volumes of industrial paints and other industrial fluids. For professional use only. See page 3 for model numbers. 500

More information

INSTRUCTIONS-PARTS LIST 30:1 RATIO PRESIDENT HYDRA-SPRAY PUMP. Wall Mount TABLE OF CONTENTS. Rev. E Supersedes Rev. D

INSTRUCTIONS-PARTS LIST 30:1 RATIO PRESIDENT HYDRA-SPRAY PUMP. Wall Mount TABLE OF CONTENTS. Rev. E Supersedes Rev. D INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 307 930 Rev. E Supersedes Rev. D Wall Mount 30:1 RATIO PRESIDENT HYDRA-SPRAY PUMP

More information

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. DISPLACEMENT PUMP 308190 Rev. K 3000 psi (210 bar) MAXIMUM WORKING PRESSURE Model

More information

Electronic Pulse Meters

Electronic Pulse Meters Instructions - Parts List Electronic Pulse Meters 308245P EN For use with petroleum-based lubricants only. 1500 psi (10.3 MPa, 103 bar) Maximum Working Pressure EFC (Electronic Fluid Commander): Model

More information

Instructions 3A4793B EN. See page 3 for a complete list of model descriptions and part numbers.

Instructions 3A4793B EN. See page 3 for a complete list of model descriptions and part numbers. Instructions Variable Frequency Drives 3A4793B EN Variable frequency drives (VFDs) to power and control electric motor driven agitators. For professional use only. Not approved for use in explosive atmospheres

More information

2:1 Ratio Standard Pump 360 psi (25 bar) MAXIMUM FLUID WORKING PRESSURE 180 psi (12.5 bar) MAXIMUM AIR INPUT PRESSURE

2:1 Ratio Standard Pump 360 psi (25 bar) MAXIMUM FLUID WORKING PRESSURE 180 psi (12.5 bar) MAXIMUM AIR INPUT PRESSURE INSTRUCTIONS PARTS LIST 307-026 This manual contains IMPORTANT WARNINGS AND INSTRUCTIONS READ AND RETAIN FOR REFERENCE 2:1 Ratio Standard Pump 360 psi (25 bar) MAXIMUM FLUID WORKING PRESSURE 180 psi (12.5

More information

Vertical Hydraulic Driver

Vertical Hydraulic Driver Repair-Parts Vertical Hydraulic Driver 3A001C EN For use with a vertically mounted proportioning pump. For professional use only. D30 - Vertical Hydraulic Driver 100 psi (8. MPa, 8.7 bar) Maximum Working

More information

Displacement Pump INSTRUCTIONS-PARTS LIST psi (250 bar, 24.8 MPa) Maximum Working Pressure Model , Series A. Model , Series A

Displacement Pump INSTRUCTIONS-PARTS LIST psi (250 bar, 24.8 MPa) Maximum Working Pressure Model , Series A. Model , Series A INSTRUCTIONS-PARTS LIST 309277 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. First choice when quality counts. Rev. B Displacement Pump 3600 psi (250

More information

Hose Heat Control Kit

Hose Heat Control Kit Instructions - Parts 248921 Hose Heat Control Kit 310798D For monitoring and controlling fluid temperature in low voltage heated hose. Not for use in explosive atmospheres. Important Safety Instructions

More information

Displacement Pump 3600 psi (250 bar, 24.8 MPa) Maximum Working Pressure Model , Series A

Displacement Pump 3600 psi (250 bar, 24.8 MPa) Maximum Working Pressure Model , Series A INSTRUCTIONS-PARTS LIST 308798 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. First choice when quality counts. Rev. U Displacement Pump 3600 psi (250

More information

Instructions Parts List. Table of Contents F. Part No Part No

Instructions Parts List. Table of Contents F. Part No Part No Instructions Parts List PrecisionFlo XL Metering Valve For use when dispensing fluids that meet at least one of the following conditions for non-flammability: The fluid has a flash point above 140F (60C)

More information

Split Manifold Kits. Installation Parts List C. Converts Husky 307 Diaphragm Pump to dual fluid inlet or outlet

Split Manifold Kits. Installation Parts List C. Converts Husky 307 Diaphragm Pump to dual fluid inlet or outlet Installation Parts List Split Manifold Kits 0849C Converts Husky 07 Diaphragm Pump to dual fluid inlet or outlet Part No. 2720 For Husky 07 Polypropylene Pumps Part No. 272 For Husky 07 cetal Pumps Important

More information

Zip-Tex Spray Gun. Instructions A. Model psi (0.86 MPa, 8.6bar) Maximum Working Pressure

Zip-Tex Spray Gun. Instructions A. Model psi (0.86 MPa, 8.6bar) Maximum Working Pressure Instructions Zip-Tex Spray Gun 311159A - For water-based materials only - (Consult your material supplier for Warnings and Application Requirements) Model 249458 125 psi (0.86 MPa, 8.6bar) Maximum Working

More information

Air Regulator 100 psi (.7 MPa, 7 bar) Maximum Air Inlet Pressure

Air Regulator 100 psi (.7 MPa, 7 bar) Maximum Air Inlet Pressure INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. First choice when quality counts. 30934 Rev. A Air Regulator 00 psi (.7 MPa, 7

More information

Repair D EN. Displacement Pump. Model , Series A 190ES/ 210ES, 190LTS/210LTS Pro 230ES, Pro 270ES Pro 270GS

Repair D EN. Displacement Pump. Model , Series A 190ES/ 210ES, 190LTS/210LTS Pro 230ES, Pro 270ES Pro 270GS Repair Displacement Pump 312015D EN Model 255198, Series A 190ES/ 210ES, 190LTS/210LTS Pro 230ES, Pro 270ES Pro 270GS Maximum Working Pressure 3300 psi (223 bar, 23 MPa) Important Safety Instructions Read

More information

810201,810202,810203,810204

810201,810202,810203,810204 810201,810202,810203,810204 IP02 SERIES 2:1 RATIO TRANSFER PUMP OPERATIONING MANUAL WITH PARTS IDENTIFICATION IPM, INC. Manufactured by International Pump Manufacturing, Inc. IP02 series 2:1 RATIO TRANSFER

More information

RS Gun Front Adapter Kits

RS Gun Front Adapter Kits Kit Instructions RS Gun Front Adapter Kits 332520A EN For adapting the internal mix gun for specific field applications. For professional use only. Important Safety Instructions Read all warnings and instructions

More information

PRO Auto Xs Air Spray Gun

PRO Auto Xs Air Spray Gun Instructions/Parts List ELECTROSTATIC, FOR WATERBORNE COATINGS PRO Auto Xs Air Spray Gun 309457G EN Part No. 244591, Series A 100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure 100 psi (0.7 MPa, 7 bar)

More information

Parts 3A2528C EN. Mark VII Max, Mark X Premium, and Mark X Max Electric Airless Sprayers

Parts 3A2528C EN. Mark VII Max, Mark X Premium, and Mark X Max Electric Airless Sprayers Parts Mark VII Max, Mark X Premium, and Mark X Max Electric Airless Sprayers 3A2528C EN For Portable Airless Spraying of Architectural Coatings and Paints. For professional use only. Not approved for use

More information

ASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings.

ASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings. Instruction-Parts ASM Maxi Poles 312483B For the application of architectural paints and coatings. 3400 Series 4050 psi (27.92 MPa, 280 bar) Maximum Working Pressure Important Safety Instructions Read

More information

Single Acting and Double Acting Paint Spray Guns for RoadLazer RoadPak Line Striping System

Single Acting and Double Acting Paint Spray Guns for RoadLazer RoadPak Line Striping System Instructions Single Acting and Double Acting Paint Spray Guns for RoadLazer RoadPak Line Striping System 308613H EN - For the application of road marking paints and coatings - - For professional use only

More information

Elevators and Pump Supports

Elevators and Pump Supports Instructions Parts List Elevators and Pump Supports 306287V Used to raise and lower select Graco circulation and supply pumps. For professional use only. 200 psi (.4 MPa, 4 bar) Maximum Air Input Pressure

More information

Instructions/Parts List

Instructions/Parts List Instructions/Parts List FOR 2: RATIO STANDARD PUMPS Standard Air Motor 30785L 80 psi (.25 MPa, 2.5 bar) Maximum Air Working Pressure Model 204464, Series B For Pump Model 204456 Model 204722, Series C

More information

INSTRUCTIONS. US Patent Pending HVLP Turbine Guns

INSTRUCTIONS. US Patent Pending HVLP Turbine Guns INSTRUCTIONS 309317 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. Rev. A US Patent Pending HVLP Turbine Guns 10 psi (0.07 MPa,.7 bar) Maximum Inlet

More information

Displacement Pump Used in the Ultra Max 695 Sprayers 3000 psi (207 bar, 21 MPa) MAXIMUM WORKING PRESSURE

Displacement Pump Used in the Ultra Max 695 Sprayers 3000 psi (207 bar, 21 MPa) MAXIMUM WORKING PRESSURE INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 308815 Rev. J Displacement Pump Used in the Ultra Max 695 Sprayers 3000 psi (207

More information

Proportioning pumps and hydraulic cylinders used on Hydraulic Proportioners. Model : 2000 psi (13.8 MPa, 138 bar) Maximum Working Pressure

Proportioning pumps and hydraulic cylinders used on Hydraulic Proportioners. Model : 2000 psi (13.8 MPa, 138 bar) Maximum Working Pressure - Parts Proportioning Pumps 3068F Proportioning pumps and hydraulic cylinders used on Hydraulic Proportioners. Important Safety Instructions Read all warnings and instructions in this manual and in manuals

More information

Stainless Steel 1000cc Lower

Stainless Steel 1000cc Lower Instructions - Parts List Stainless Steel 1000cc Lower 311716C ENG Designed for low to medium pressure, medium volume circulation of finishing materials. For professional use only. Not approved to European

More information

PROVEN QUALITY, LEADING TECHNOLOGY

PROVEN QUALITY, LEADING TECHNOLOGY Instructions Parts List Fluid Outlet Filter 303Z For filtering of finishing materials. For professional use only. Important Safety Instructions Read all warnings and instructions in this manual. Save these

More information

INSTRUCTIONS-PARTS LIST

INSTRUCTIONS-PARTS LIST INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. First choice when quality counts. 307 620 Rev. M Supersedes J and PCN K PORTABLE

More information

Instructions Parts List

Instructions Parts List Instructions Parts List WITH OR WITHOUT ELECTRONIC METERS V5 V12 EM6 and EM12Dispense Valves 308642N For dispense of petroleum and synthetic based oils. 1500 psi (10 MPa, 102 bar) Maximum Working Pressure

More information

Texture Gun & Hopper

Texture Gun & Hopper Operation and Parts Texture Gun & Hopper 309584H - For Water-Based Materials Only - Model 245924 Series A, B, and C 100 psi (7 bar, 0.7 MPa) Maximum Working Air Pressure 60 psi (4.1 bar, 0.41 MPa) Maximum

More information

Instructions Parts List

Instructions Parts List Instructions Parts List DOUBLE ACTING Falcon and Falcon II Air Motors 08995E Part No. 41504, Series C Falcon Air Motor 150 psi (1.0 MPa, 10 bar) Maximum Air Input Pressure Part No. 41505, Series C Falcon

More information

Integrated and 2-Button Interlock Air Controls for use with Supply Systems.

Integrated and 2-Button Interlock Air Controls for use with Supply Systems. Instructions-Parts Air Controls 312374A Integrated and 2-Button Interlock Air Controls for use with Supply Systems. Important Safety Instructions Read all warnings and instructions in this manual. Save

More information

50:1 Ratio Fire-Ball Pumps

50:1 Ratio Fire-Ball Pumps INSTRUCTIONS PARTS LIST 306 517 This manual contains important warnings and information. READ AND RETAIN FOR REFERENCE Rev. S Supersedes P and PCN R 50:1 Ratio Fire-Ball Pumps FOR LUBRICATING PRODUCTS

More information

Displacement Pump 3600 psi (250 bar, 24.8 MPa) Maximum Working Pressure Model , Series A

Displacement Pump 3600 psi (250 bar, 24.8 MPa) Maximum Working Pressure Model , Series A INSTRUCTIONS-PARTS LIST 309277 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. First choice when quality counts. Rev. M Displacement Pump 3600 psi (250

More information

950SeriesSealantGun. Instructions-Parts D. Models Palm Grip Gun: Pistol Grip Gun: ENG

950SeriesSealantGun. Instructions-Parts D. Models Palm Grip Gun: Pistol Grip Gun: ENG Instructions-Parts 950SeriesSealantGun 309968D ENG For dispensing sealant from caulking tubes. For professional use only. Important Safety Instructions Read all warnings and instructions in this manual.

More information

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5 MODELS 282050, 282716 & 283513 AIR OPERATED CHASSIS PUMP SERIES A OWNER/OPERATOR MANUAL SPECIFICATIONS Airmotor effective dia. in. 2.5 Airinlet Material outlet 1/4 NPTF 1/4 NPTF Liquid to Air Pressure

More information

D Instructions/Parts. Siphon Feed Detail Spray Gun D

D Instructions/Parts. Siphon Feed Detail Spray Gun D Instructions/Parts D-5-55 Siphon Feed Detail Spray Gun FOR PRODUCT INFORMATION CALL: 1-800-742-7731 309991D Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.

More information

4:1 Fusion Static Mixer Kit

4:1 Fusion Static Mixer Kit Instructions-Parts 4:1 Fusion Static Mixer Kit 1294A For use with 4:1 ratio material and Graco Fusion MP gun only. Not for use in explosive atmospheres. 500 psi (24.5 MPa, 245 bar) Maximum Fluid Working

More information

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup. Instructions/Parts MGFHVLP Mini Gravity Feed System FOR PRODUCT INFORMATION CALL: 1-800-742-7731 309989E For gravity feed spraying of automotive colors and clears. Ideal for touch-up and detail work. Important

More information

Horizontal Hydraulic Driver

Horizontal Hydraulic Driver Repair-Parts Horizontal Hydraulic Driver 3A000A ENG For use with two horizontally mounted proportioning pumps. For professional use only. Not for use in explosive atmospheres. 5877 - Horizontal Hydraulic

More information

INSTRUCTIONS-PARTS LIST. BLACK MAX Airless Spray Gun psi (24.8 MPa, 248 bar) Maximum Working Pressure. Rev. F Supersedes D and PCN E

INSTRUCTIONS-PARTS LIST. BLACK MAX Airless Spray Gun psi (24.8 MPa, 248 bar) Maximum Working Pressure. Rev. F Supersedes D and PCN E INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. First choice when quality counts. 307 821 Rev. F Supersedes D and PCN E BLACK

More information

Water Sandblaster Kit

Water Sandblaster Kit a Instructions - Parts List Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. Water Sandblaster Kit 308544 - For suction fed injection of sand into

More information

Split Manifold Kits. Installation - Parts List D. Converts Huskyt 307 Diaphragm Pump to dual fluid inlet or outlet

Split Manifold Kits. Installation - Parts List D. Converts Huskyt 307 Diaphragm Pump to dual fluid inlet or outlet Installation - Parts List Split Manifold Kits 0849D Converts Huskyt 07 Diaphragm Pump to dual fluid inlet or outlet Part No. 2720 For Husky 07 Polypropylene Pumps Part No. 272 For Husky 07 cetal Pumps

More information

UltraMix Pumps. Repair - Parts A

UltraMix Pumps. Repair - Parts A Repair - Parts UltraMix Pumps 310671A Read warnings and instructions. See page 3 for model information, including maximum working pressure and approvals. TI4598a Graco Inc. P.O. Box 1441 Minneapolis, MN

More information

T1-Titanium Non-HVLP Spray Gun

T1-Titanium Non-HVLP Spray Gun T1-Titanium Non-HVLP Spray Gun THE SPRAY GUN PEOPLE FOR PRODUCT INFORMATION CALL: 1-800-742-7731 Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions.

More information

PROVEN QUALITY. LEADING TECHNOLOGY.

PROVEN QUALITY. LEADING TECHNOLOGY. Instructions Stainless Steel, Air Operated Dispensing Valve 306715M EN 3000 psi (21 MPa, 210 bar) Maximum Working Pressure Model No. 205612, Series B Without seat or fluid needle. Model No. 205435 Includes

More information

Displacement Pump. Repair-Parts. Contents D ENG. Part No psi (13.8 MPa, 138 bar) Maximum Working Pressure

Displacement Pump. Repair-Parts. Contents D ENG. Part No psi (13.8 MPa, 138 bar) Maximum Working Pressure Repair-Parts Displacement Pump 313383D ENG For use with polyurethane foam, polyurea, and similar non-flammable material. For professional use only. Not for use in explosive atmospheres. Part No. 257344

More information

390 Airless Sprayer. Parts J EN. Models: , , , , , ,262024, , , , Hi-Boy.

390 Airless Sprayer. Parts J EN. Models: , , , , , ,262024, , , , Hi-Boy. Parts 390 Airless Sprayer 37J EN Models: 253958, 254998, 2209, 25498, 25499, 2539,22024, 2539, 25392, 2548, 82084 Important Safety Instructions Read all warnings and instructions in the Operation and Repair

More information

3:1 Ratio President Pump

3:1 Ratio President Pump INSTRUCTIONS-PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 307 674 Rev. G Supersedes D and PCN F 3:1 Ratio President Pump 360 psi (25 bar)

More information

Proportioning Pumps. Repair - Parts M EN

Proportioning Pumps. Repair - Parts M EN - Parts Proportioning Pumps 3068M EN Proportioning pumps and hydraulic cylinders used on Hydraulic Proportioners. For professional use only. For professional use only. Not for use in explosive atmospheres.

More information

INSTRUCTIONS PARTS LIST Rev. D

INSTRUCTIONS PARTS LIST Rev. D INSTRUCTIONS PARTS LIST 307 860 Rev. D This manual contains IMPORTANT WARNINGS AND INSTRUCTIONS READ AND RETAIN FOR REFERENCE Supersedes B Model AS4000M MANUAL ELECTROSTATIC METALLIC AIR SPRAY GUN 100

More information

Pistol Grip Mastic Flo Gun

Pistol Grip Mastic Flo Gun Instructions Parts List Pistol Grip Mastic Flo Gun 308206E For spraying highly filled texture materials. 4050psi (27.6 MPa, 276 bar) Maximum Working Pressure Model 224990, Series A; Model 289670 With Diffuser,

More information

Instructions Parts List

Instructions Parts List 06372 Instructions Parts List STAINLESS STEEL, AUTOMATIC Hydra Spray Guns, less tip 306815L For Automatic, Airless, Circulating, and Non Circulating Systems 3000 psi (21 MPa, 210 bar) Maximum Working Pressure

More information

INSTRUCTIONS-PARTS LIST

INSTRUCTIONS-PARTS LIST INSTRUCTIONS-PARTS LIST 308968 INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. First choice when quality counts. Rev. C Part No. 233021 Part No. 617418

More information

3600 psi (250 bar, 24.8 MPa) Maximum Working Pressure Model , Series A Ultra Max II and Ultimate Mx II 695 and 795

3600 psi (250 bar, 24.8 MPa) Maximum Working Pressure Model , Series A Ultra Max II and Ultimate Mx II 695 and 795 Repair Displacement Pump 310643H 3600 psi (250 bar, 24.8 MPa) Maximum Working Pressure Model 248204, Series A Ultra Max II and Ultimate Mx II 695 and 795 Model 248205, Series A Ultra Max II and Ultimate

More information

SaniForce Air Motors. Instructions/Parts 3A1211N

SaniForce Air Motors. Instructions/Parts 3A1211N Instructions/Parts SaniForce Air Motors 3A2N EN For use on SaniForce piston pumps, which are used to transfer medium to high viscosity fluids in applications requiring high sanitation. For professional

More information

Model PRO 3500hc Electrostatic Air Spray Gun 65 kv, HIGH CONDUCTIVITY, MANUAL GUN

Model PRO 3500hc Electrostatic Air Spray Gun 65 kv, HIGH CONDUCTIVITY, MANUAL GUN INSTRUCTIONS-PARTS LIST This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 308018 Rev. W INSTRUCTIONS Model PRO 3500hc Electrostatic Air Spray Gun 65 kv, HIGH CONDUCTIVITY,

More information