CLARKSON URETHANE KNIFE GATE VALVES FIGURE SU10R

Size: px
Start display at page:

Download "CLARKSON URETHANE KNIFE GATE VALVES FIGURE SU10R"

Transcription

1 CLARKSON URETHANE KNIFE GATE VALVES Installation and maintenance instructions for field replaceable urethane lined knife gate valves GENERAL INFORMATION The Clarkson SU10R knife gate valve offers bi-directional isolation with a field replaceable liner that completely protects the wetted area from abrasion and corrosive slurries, increasing reliability and service life. Note: 1. Face to Face to MSS SP Bi-directional valve, no special concerns in relation to direction of flow are required when installing the valve. 3. Mating line flanges must be properly aligned. Never try to make up for misaligned pipe flanges by the line bolting. 4. Slip-on or weld flanges can be used. The flange inside diameter can t be any larger that the outside diameter of schedule 40 pipe, plus 2mm (3/32). Generally, the life and sealing will be better with full face flanges. 5. Flange fasteners should be tightened in a uniform manner using a cross-pattern to pull the flange down uniformly onto the integral flange seal. Additional gaskets are not required but a hard compressed fiber sheet gasket can be used if desired. Do not use soft gaskets. Compression of the liner flange locks it to the valve body 6. Pipe supports and/or expansion joints should be used to minimize pipe loads on valves. SU10R valves are suitable for use in either vertical or horizontal lines. If installation is other than vertical, additional support will be required for cylinder actuated valves. INITIAL INSPECTION 1. Examine entire valve and report any damage or discrepancies immediately. 2. Accessories, if any, including solenoids, limit switches, positioners, etc., are tested for functionality prior to shipment. Examine carefully for damage which may occur during shipment. 3. Operators: Large manual hand wheels may sometimes be shipped loose for field installation. 4. Packing assembly: The packing gland bolts should be checked and adjusted to obtain a first time packing seal. Packing glandnuts may become slightly loose when the valve is shipped. This is normal. Field adjustment is expected and desired. Tighten just enough to stop any leakage. Overtightening may increase valve operating force and shorten packing life. Label contents Item Description Example MAWP Maximum allowable working pressure 1000 kpa Comply Manuf. Ref. Manufacturers reference. N/A CRN Canadian Registation Number N/A Patent Patent N/A Size Valve nominal size DN250 Flange Valve mounting flange standard. ASME 150 Body Body material. ASTM A Gate Gate material 316 S/S Temp Maximum working temperature, wet or dry 50 C Wet/80 C Dry Emerson.com/FinalControl 2017 Emerson. All Rights Reserved. VCIOM EN 17/09

2 J K ØF C3 C4 C1 C2 ØF1 C G ØB ØA H D E Dimensions (mm) Valve Size DN ØA ØB C C1 C2 C3 C4 D E ØF ØF1 G H J K Ø P Ø P Ø P Ø P Ø B20 P SQ B20 P Ø B20 P Ø B20 P Ø B20 P Ø B20 P Ø B30 P Ø BG44GT P18 Dimensions (inches) Valve Size NPS ØA ØB C C1 C2 C3 C4 D E ØF ØF1 G H J K Ø P Ø P Ø P Ø P Ø BG3 P SQ BG3 P SQ BG3 P SQ BG3 P SQ BG4 P SQ BG42 P SQ BG42 P Ø BG44GT P18 H/W mass (kg) H/W mass (lbs) B/gear Pneu mass act mass (kg) (kg) B/gear Pneu mass act mass (lbs) (lbs) Bevel gear model Bevel gear model Pneu Act model Pneu Act model NOTES: D = The face to face dimension. E = The maximum valve or upstand clearance dimension for installation. G = The maximum valve width clearance dimension for installation. P = Pneumatic actuator based on air supply pressure of 550 kpa (80 psi) and clean water service. 2

3 Bolting and Installation Instructions The SU10R flange configuration is tapped holes in the chest and through bolting through the valve flange. Flange mounting holes in the chest area have limited depth and care must be taken to ensure the flange bolt does not bottom out in the hole, causing damage to the valve body. Studs can be used instead of bolts to avoid this damage. The flange bolts are a structural component of the valve and must have a minimum yield strength. For Metric bolts, the minimum yield strength is 640MPa, which is equivalent to ISO898 Class 8.8 or better. ISO A2-80 and A4-80 stainless steel bolts are also suitable. For ASME flanges, ASME B16.5 Table 1B High Strength bolts are suitable. Flange bolts must have the required torque as shown in Table 1. Additional gaskets are not required as the Polyurethane liner flanges perform this function. If additional gaskets are desired use thin compressed fiber sheet gaskets. Do not use thick soft gaskets as the liner flange may not lock into place on the body. TABLE 1 - MINIMUM AND MAXIMUM TORQUE ON FLANGE BOLTS OR STUDS Valve size Bolt Min torque Max torque DN (NPS) size Nm (ft-lb) Nm (ft-lb) 50 (2) M M16 & ⅝ UNC (3-8) All (10) M16 & ⅝ UNC M20 and larger (12) All (14-20) M20-M M24 (+1"UNC) and larger (24) M M27 (+1 1 /4 "UNC) and larger NOTES: Maximum torque should not be exceeded to insure threaded flange holes in valve body are not damaged. Warning: Valves are normally shipped with the gate in the Open position. However, valves fitted with spring to extend actuator (Fail Close) are shipped with the gate in the Closed position. All SU10R valves are to be installed with the Gate in Open Position, exercise caution when applying air/hydraulic pressure to open valve and ensure that it is locked in Open Position when installing in-line. WARNING: Flange Bolts are structural components in valve and must comply with stated ISO or ASME grades. Care must be taken when installing studs or bolts in tapped flange holes in chest area to prevent damage to internal wall profile. 3

4 Pipe Flanges 1. SU10R polyurethane liner flange provides sealing between valve and pipe flange. 2. The liner flange is locked to valve body by a locking tab. This locking tab is compressed into the liner flange by the pipe flange, providing the locking to prevent the liner flange from moving. 3. Slip on flanges can be used on the pipe flange. However, the pipe flange must compress the polyurethane over the locking tab to locate the liner flange and provide sealing. The following conditions must be met: Inside diameter of pipe flange cannot be any larger than Schedule 40 pipe OD plus 2mm ( 5 /32) Flange ID must be concentric with valve bore during installation 4. Flat flanges, with an inside diameter of the flange matching valve bore, provides best sealing and liner life when valve is being used at its maximum allowable working pressure. Slip on flanges will still provide acceptable life. Slip On Flange Locking Tab Slip On Flange ID must cover locking tab all the way around Pipe Gate Locking Tab Body Liner Flange Valve bore 4

5 Table 2 Valve size DN (NPS) Valve Chest full Flange bolting AS 2129 Table C, D Flange bolting AS 2129 Table E Flange bolting ASME 150 face to thread Thread Chest bolt Thru bolt Chest stud Thread Chest bolt Thru bolt Chest stud Thread Chest bolt Thru bolt Chest stud face depth length length length length length length length length length mm mm mm UNC in 50 (2) M M ⅝ 1 ⅜ 4 ½ 1 ½ 80 (3) M M ⅝ 1 ½ 5 1 ¾ 100 (4) M M ⅝ 1 ½ 5 1 ¾ 150 (6) M M ¾ 1 ¾ 5 ½ (8) M M ¾ 2 6 ½ 2 ¼ 250 (10) M M ⅞ ¼ 300 (12) M M ⅞ ¼ 350 (14) M M ¼ 8 2 ½ 400 (16) M M ½ 8 ½ 2 ¾ 450 (18) M M ⅛ 2 ½ 9 2 ¾ 500 (20) M M ⅛ ¼ 600 (24) M M ¼ ¼ DETERMINING VALVE BOLT AND STUD LENGTHS WARNING: Flange and washer thickness can vary. Check flange bolting is correct length for chest bolts. Bolts that are too long will damage valve chest and/or prevent flange sealing beads from being compressed. Chest bolts that are too short could result in the chest threads stripping. Consider chest studs to avoid this issue. Note: The valve face to face is after compression of the flange seals. Face to face will be slightly bigger before valve installation. Blind Chest Thread Stud Length: Stud length = Chest full thread depth + Pipe flange thickness + Washer thickness + Nut thickness Round up or add at least 5mm to ensure there are threads outside the nut. This is an option instead of chest bolts. Through Bolt Length: Bolt length = Washer thickness + 2 x Pipe flange thickness + Valve face to face + Nut thickness Round up or add at least 5mm to ensure there are threads outside the nut. Blind Chest Thread Bolt Length: Bolt length = Washer thickness + Pipe flange thickness + Chest full thread depth. Always round down to avoid damage at bottom of tapped hole. If rounding down length by more than 3mm consider adding another flat washer and using the next bolt length up to ensure maximum thread engagement. 5

6 Clarkson URETHANE KNIFE GATE VALVEs Lock nut and cap screw DN Lock out pin goes thru gate to lock the in the open position. Lockout pin goes over the gate to lock in the close position. Lock nut all sizes Gland box adjustment Lockout pin illustration LOCKOUTS Options Optional pin style lockouts for open and closed are available for hand wheel, pneumatic and hydraulic valves. Handwheel style lockouts are available on bevel gear operated valves due to the mechanical advantage of the bevel gear. Use energy lockouts for electric, pneumatic and hydraulic cylinder actuators to lock out the actuator from the valve. Safety Pin-style lockouts assume the potential energy of the actuator has been removed through other means and are designed to prevent gate movement caused by line pressure. Lockout Pins are not designed to overcome or resist an energized pneumatic or hydraulic cylinder actuator. Pin-style lockouts are designed as a deterrent to resist unauthorized manual operation of the valve and prevent gate movement caused by line pressure. Pin style lockouts are not available on bevel gear actuated valves. A lockout that locks the bevel gear hand wheel to the gearbox is available. OPERATIONAL CONSIDERATIONS 1. All valves should be operated within their design pressure and temperature ranges. Under no circumstances should a valve be operated at conditions outside these parameters. 2. The operator should have an understanding of the effects of opening/closing a valve with regards to its role in the overall piping system. Take caution to ensure that each valve is in good operating condition prior to operating it under pressure. 3. Care should be taken when processes contain hazardous and/or otherwise unstable media to ensure the operator is aware of specific health and safety risks associated with that medium. Note that a worn out or split liner can result in leakage between valve body halves. 4. Stand clear of any moving parts such as the stem and/or gate assembly when operating, use of gloves is suggested when operating manual valves to minimize risk of injury. 5. All manual handwheel operated valves are designed for hand input. Do not apply excessive input torque via pipe wrenches, 'cheater bars', or other devices. If a manual handwheel actuated valve is difficult to operate due to torque requirements, it is recommended that the valve be supplied with or converted to a bevel gear, air/ hydraulic cylinder or electric motor actuator. 6. Electric motor actuated valves should be left in their factory set condition unless the system operating parameters dictate a change. If changes are necessary, they should be performed in small increments using the lightest/lowest setting possible to achieve the desired performance and then the valve/actuator function inspected. Excess torque and/or thrust in the motor settings may damage the valve or liner. 7. For electric motor actuation the travel switches must be set, otherwise liner damage may occur. The limit should be set such that the gate tip bottoms out in seat groove to a maximum of 1mm compression. 8. Care should be taken to ensure that electrical motors are wired correctly. Incorrect phasing of 3-phase wiring may cause valve/motor damage. 6

7 GENERAL MAINTENANCE It is recommended that all Clarkson SU10R series valves be inspected every 60 days. The following points should be examined and corrected as required: 1. Cylinder rods: Wipe to remove build up if required. Look for wear. Check for cylinder rod seal blow-by. 2. Packing gland: Check for leaks or worn packing. If leakage is occurring around the packing gland, tighten the packing gland bolts evenly at all points, being careful not to over tighten. If the valve requires repacking, see additional instructions. 3. Polyurethane liner: Examine the body for leakage between body halves. Leakage could indicate the liner is split or worn through. To replace a liner, disassembly of the valve is required. See additional instructions. 4. If possible, stroke valve through the full open and closed position to make sure it is functioning properly. 5. Check the liner flanges are sealing. Check flange bolt torques if leakage is evident. Note: If the valve is not in line the gate should be open. This is the best storage position for liner sealing. GLAND PACKING INSTRUCTIONS 1. Prepare the line and valve to be off line and dismantled. 2. Retract the gate to make it easier to withdraw from the liner. Warning, if the liner and gate are worn, the gate may close under its own weight. If this is the case, leave the gate in the closed position as it will be easy to withdraw from the liner. 3. Disconnect the clevis pins or bolts from the gate. 4. Remove the actuator and bridge. 5. Remove the gate and gland box. For large valves, the gate will be heavy and it may be desirable to leave the gate in the body. The options then are to repack the gland box and then fit it over the gate or to place the gland box over the gate and then repack the gland box. Both methods will require some care. 6. See the table below for packing details. 7. Packing should be cut with 45 degree mitres on the ends of each piece of packing. These mitres sit on top of each other and the join should be placed in the middle of the long side of the gland box. 8. Packing is slightly longer that the gland box length, to ensure there is compression on the join. 9. Joins for different layers of packing should be staggered to the opposite side so that there are not 2 joins in contact with each other. 10. Work the layer of packing around the gate being sure not to have any twist. 11. Once the first layer of packing is installed, neatly continue with the second layer. The DN600 (NPS 24) only has a third layer. 12. Use a blunt tool, such as that shown in the photos, to work the packing. This will avoid damaging the packing or gland box paint. It is also safer for the installer. 13. Refit the bridge and actuator. Reconnect the clevis pin/bolts 14. Adjust packing nuts firmly, without over tightening. 15. Cycle the gate several times. This will distribute the packing evenly and normally reduce the packing compression. Adjust gland box nuts again. 16. Commission valve in the pipeline and adjust packing until it seals. PACKING Details Valve Size Length Section Layers DN (NPS) mm (in) mm (in) 50 (2) 196 (7.72) 10 (⅜) 2 80 (3) 260 (10.24) 10 (⅜) (4) 310 (12.20) 10 (⅜) (6) 430 (16.93) 12.7 (½) (8) 537 (21.14) 12.7 (½) (10) 650 (25.59) 12.7 (½) (12) 745 (29.33) 12.7 (½) (14) 850 (33.46) 12.7 (½) (16) 940 (37.01) 12.7 (½) (18) 1040 (40.94) 12.7 (½) (20) 1140 (44.88) 14 (9/16) (24) 1370 (53.94) 15 (9/16) 3 1). Start the packing in the middle of the long side. 2). Work the packing around with a blunt tool. 3). The packed gland box. 7

8 CYLINDER SUPPORT METHODS FOR HORIZONTALLY OR OFF-VERTICAL MOUNTING Cylinders may require additional support when mounted in the other than vertical position. Failure to do so could lead to premature failure of cylinder and/or valve. The following illustrations are suggestions; specific details will have to be determined by customer so support best suits surrounding area. It is important that the cylinder/gate alignment be maintained during valve operation. Supports should be designed to maintain alignment and support bulk of cylinder weight. Installation A Appropriate tie-in capable of supporting load Turnbuckle for adjustment saddle style hanger Installation b Recommended long term storage The following are recommendations for storage procedures to retain maximum product integrity during long term storage of 1 to 5 years. Storage facility The preferred storage location is a clean, dry protected warehouse. If valves are to be stored outside, precautions should be taken to keep valves clean and dry. Standard packaging materials cannot be considered sufficient for outdoor storage. Handwheel or bevel gear operated valves Equipment orientation Valves may be stored in the vertical or horizontal position Preparation for storage Valves may be stored as shipped, provided the storage facility and equipment orientation instructions above are followed. If valve packaging is altered or removed for receiving inspection, repackage valve as originally received. Standard packaging materials cannot be considered sufficient for outdoor storage. Cylinder storage These cylinder storage instructions are not intended to replace the instructions of the specific cylinder manufacturer and are to be used as a guide only. If specific instructions are required, please contact our office. For storage of up to 3 years; operate cylinder 6-12 times on a yearly basis. For storage 3-5 years; Securely plug cylinder ports with pipe plugs, if cylinder is not prepiped to control accessories. If cylinder is prepiped to accessories, plug all input and output ports of accessories. Storage inspection Visual inspection shall be performed on a semiannual basis and results recorded. Inspection as a minimum shall include reviewing the following: Packaging Flange covers Dryness Cleanliness Maintenance Maintenance shall consist of correcting deficiencies noted during inspection. All maintenance shall be recorded. Contact factory prior to performing any maintenance if valve is still covered under warranty. CYLINDER OPERATED VALVES Saddle style support Appropriate tie-in capable of supporting load Installation C Appropriate tie-in capable of supporting load Turnbuckle for adjustment Appropriate head-support, saddle style perferred Equipment orientation Valves may be stored in the vertical or horizontal position. For large pneumatic actuators P7 and above, or for all spring return cylinders, the actuator must be supported in storage. This is to ensure the actuator load is taken off the valve top works and the valve gate/ liner. Preparation for storage Valves may be stored as shipped, provided the storage facility and equipment orientation instructions above are followed. If valve packaging is altered or removed for receiving inspection, repackage valve as originally received. Standard packaging materials cannot be considered sufficient for outdoor storage. 8

KEYSTONE KNIFE GATE VALVE FIGURE OS1700

KEYSTONE KNIFE GATE VALVE FIGURE OS1700 Installation and maintenance instructions for Class 150 knife gate valves GENERAL INFORMATION The Keystone OS1700 knife gate valve is a bidirectional zero leakage ASME Class 150 rated knife gate valve.

More information

CLARKSON KNIFE GATE VALVE MODEL ZP3OO INSTALLATION AND MAINTENANCE INSTRUCTIONS

CLARKSON KNIFE GATE VALVE MODEL ZP3OO INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood GENERAL INFORMATION The Clarkson ZP300 knife gate valve is designed to meet extremely rugged and challenging requirements of expansible

More information

Keystone knife gate valves Figure OS1700

Keystone knife gate valves Figure OS1700 Bi-directional zero leakage ASME Class 150 rated knife gate valve. Designed for the rigors of high pressure slurry and oil sands applications Features General application The OS1700 has many features to

More information

Fabri-Valve Push Through Slurry Valve SV1. Engineered Valves

Fabri-Valve Push Through Slurry Valve SV1. Engineered Valves Fabri-Valve Push Through Slurry Valve SV1 Engineered Valves Fabri-Valve SV1 - Push Through Slurry Valve The Fabri-Valve SV1 Push-Through Slurry Valve is one of the most versatile knife gate valve configurations

More information

Clarkson Slurry Knife Gate Valves KGA and KGA+

Clarkson Slurry Knife Gate Valves KGA and KGA+ KGA and KGA+ Installation and maintenance instructions KGA+ index Clarkson KGA+ valve assemblies 1. General information... 2 2. Initial inspection... 2 3. Installation instructions... 3 4. Operation...

More information

CLARKSON SERIES KGF AND KGF-HP SLURRY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

CLARKSON SERIES KGF AND KGF-HP SLURRY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood This instruction manual provides installation, operation and maintenance recommendations for both the Clarkson KGF and Clarkson

More information

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL FRP BALL VALVES TABLE OF CONTENTS MAINTENANCE AND INSTALLATION INSTRUCTIONS 1. 2. 2.1 2.2 2.3 2.4 GENERAL...Page 1 HANDLING...1 Receiving and Storing...1

More information

Maintenance instruction

Maintenance instruction Maintenance instruction This maintenance instruction is a step-by-step instruction for service and maintenance on Stafsjö s HG valve. Same procedure also applies for HL, HP and HPT. The instruction shall

More information

OPERATION AND MAINTENANCE INSTRUCTIONS

OPERATION AND MAINTENANCE INSTRUCTIONS OPERATION AND MAINTENANCE INSTRUCTIONS 334 SERIES THREE-PIECE BALL VALVES 1/4 to 2-1/2 Installation and Operation Always install your valve according to accepted industry standards and practices and operate

More information

IOM Manual. IOM Manual. Series 76/77.

IOM Manual. IOM Manual. Series 76/77. IOM Manual IOM Manual Series 76/77 www.flowlinevalves.com Flow Line Valve and Controls, L.L.C. 110 Main Project Road Schriever, LA 70395 P.O. Box 677 Schriever, LA 70395 Phone 985-414-6004 * Toll Free

More information

DeZURIK KSV CL150 & CL300 BONNETLESS KNIFE GATE VALVES

DeZURIK KSV CL150 & CL300 BONNETLESS KNIFE GATE VALVES KSV CL150 & CL300 BONNETLESS KNIFE GATE VALVES Instruction D11021 October 2016 Instructions These instructions provide information about DeZURIK KSV CL150 & CL300 knife gate valves. They are intended for

More information

J Flow Controls Model Numbering

J Flow Controls Model Numbering 4665 Interstate Dr Cincinnati, OH 45246 Phone 513-731-2900 Fax 513-731-6939 3500 Series Valve Instruction and Maintenance Manual Caution: Prior to performing any repairs or maintenance on the valve assembly,

More information

KEYSTONE PNEUMATIC ACTUATOR FIGURE 738

KEYSTONE PNEUMATIC ACTUATOR FIGURE 738 The F78 is a linear pneumatic actuator, designed especially for use on linear actuated valves FEATURES Suits all linear actuated valves. The Keystone F78 pneumatic actuator series is engineered to provide

More information

KEYSTONE SERIES GRF RESILIENT SEATED BUTTERFLY VALVES INSTALLATION AND OPERATION MANUAL

KEYSTONE SERIES GRF RESILIENT SEATED BUTTERFLY VALVES INSTALLATION AND OPERATION MANUAL Before installation these instructions must be fully read and understood Intended valve use The valve is intended to be used only in applications within the pressure/temperature limits indicated in the

More information

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822 Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822 Statements: NIBCO High Performance Butterfly Valves, Series 6822 and 7822, have been designed

More information

HD150/HD300 Heavy Duty Knife Gate Valve

HD150/HD300 Heavy Duty Knife Gate Valve Fabri-Valve HD150/HD300 Heavy Duty Knife Gate Valve HEAVY DUTY VALVES FOR THE OIL SANDS INDUSTRY Heavy Duty Knife Gate Valve The HD150 and HD300 Heavy Duty Knife Gate Valve The Fabri-Valve HD line of Heavy

More information

Fisher POSI-SEAL A31D Double-Flange High-Performance Butterfly Valve

Fisher POSI-SEAL A31D Double-Flange High-Performance Butterfly Valve Instruction Manual A31D Valve Fisher POSI-SEAL A31D Double-Flange High-Performance Butterfly Valve Contents Introduction... 1 Scope of Manual... 1 Description... 2 A31D Valve Specifications and Materials

More information

DeZURIK KUL KNIFE GATE VALVES

DeZURIK KUL KNIFE GATE VALVES KUL KNIFE GATE VALVES Instruction D11025 September 2013 Instructions These instructions are intended for personnel who are responsible for the installation, operation and maintenance of your KUL knife

More information

Gearbox Installation Manual

Gearbox Installation Manual Gearbox Installation Manual Rotork Gears IW, MOW, MTW, IB and IS ranges (Electronic copy available on www.rotork.com)! This manual contains important safety information. Please ensure it is thoroughly

More information

INSTALLATION - MAINTENANCE MANUAL Severe Service Series M4 Ball Valve

INSTALLATION - MAINTENANCE MANUAL Severe Service Series M4 Ball Valve INSTALLATION - MAINTENANCE MANUAL Severe Service Series M4 Ball Valve Date: May 2016/ Page 2 of 12 Table of Contents 1. Safety Information - Definition of Terms..........................2 2. Bill of Materials....................................

More information

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves Installation, Operation, Maintenance Instructions Standard Valves Series 035 000 Globe Valves Series 031 000 Angle Valves Series 033 000 3-Way-Valves 1 GENERAL INFORMATION These instructions are designed

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL. 0.- Description Handling Installation Actuators Maintenance...

INSTALLATION, OPERATION & MAINTENANCE MANUAL. 0.- Description Handling Installation Actuators Maintenance... INSTALLATION, OPERATION & MAINTENANCE MANUAL INDEX Page 0- Description 2 1- Handling 2 2- Installation 2 3- Actuators 5 4- Maintenance 5 41- Gland packing replacement 5 42- Seal replacement 6 43- Gasket

More information

Fabri-Valve. CF33/CF133 Ported Slide Gate Valve

Fabri-Valve. CF33/CF133 Ported Slide Gate Valve Fabri-Valve CF33/CF133 Ported Slide Gate Valve CF33/CF133 Ported Slide Gate Valve Fabri-Valve Figures C33 / C133 / F33 / F133 are bi-directional soft seated, slide gate valves designed for on/off service

More information

KEYSTONE FIGURES 310/312 K-LOK BUTTERFLY VALVES

KEYSTONE FIGURES 310/312 K-LOK BUTTERFLY VALVES 310 - Wafer high performance butterfly valve 312 - Lugged high performance butterfly valve FEATURES GENERAL APPLICATION High performance applications such as steam, chill water, water, utility lines, gasoline,

More information

WKM Model MB DynaCentric High Performance Butterfly Valve

WKM Model MB DynaCentric High Performance Butterfly Valve Document Number: TC003001-10 Revision: Rev 1 WKM Model MB DynaCentric High Performance Butterfly Valve Installation, Operation, and Maintenance Manual TABLE OF CONTENTS BILL OF MATERIALS... 3 CATALOG NUMBER

More information

Bray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual

Bray/ VAAS Slurry Series Knife Gate Valve 760/762/765/766/767/768 Series Operation and Maintenance Manual Bray/ VAAS Knife Gate Valve 760/762/765/766/767/768 Series Table of Contents Definition of Terms 1 Safety Instructions 1 Introduction 2 Unpacking 2 Storage 2 Installation 3 Commissioning 3 Cylinder-Operated

More information

Sub Section Title Page No.

Sub Section Title Page No. Sub Section Title Page No. 1 Introduction 3 2 Routine Maintenance 3 3 Disassembly 4 3.1 Disassembly of Double Crank Design 4 3.2 Disassembly of Scotch Yoke Design 5 3.3 Disassembly of Actuator Cylinder

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Industrial Process Installation, Operation, and Maintenance Manual Cam-Tite Ball Valve Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health and safety...2

More information

Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions

Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions Instruction Manual D103356X012 24000C Control Valve Baumann 24000C Carbon Steel Little Scotty Control Valve Instructions CONTENTS Introduction...1 Scope...1 Safety Precautions...1 Maintenance...2 Flow

More information

Fabri-Valve. C67 Bi-Directional Knife Gate Valve

Fabri-Valve. C67 Bi-Directional Knife Gate Valve Fabri-Valve C67 Bi-Directional Knife Gate Valve C67 Bi-Directional Knife Gate Valve The Fabri-Valve Figure C67 features a unique, patented*, perimeter seal that provides bi-directional shutoff. The seal

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL Description Handling Installation Actuators...

INSTALLATION, OPERATION & MAINTENANCE MANUAL Description Handling Installation Actuators... INSTALLATION, OPERATION & MAINTENANCE MANUAL INDEX Page 0 - Description 2 1 - Handling 2 2 - Installation 2 3 - Actuators 5 4 - Maintenance 5 41 - Gland packing replacement 6 42 - Seal replacement 6 43

More information

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM.  QAD#IM6055.REVA LSSN Butterfly Valve Installation Operation Maintenance Licence Number: 5326 www.challengervalves.com.au 1 Index 1. INTRODUCTION 1.1 Design Features 3 1.2 Flange and Pipe Compatibility 4 1.3 Operating

More information

SLURRY KNIFE GATE VALVE

SLURRY KNIFE GATE VALVE SERIES D FLEXGATE SLURRY KNIFE GATE VALVE Installation, Operation and Maintenance Manual The Red Valve Series D Flexgate Slurry Knife Gate Valve is a 100% full bore, truly bi-directional valve designed

More information

Baumann Way Control Valve

Baumann Way Control Valve Instruction Manual 24003 Valve Baumann 24003 3-Way Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Educational Services... 3 Maintenance... 3 Installation... 3 Air

More information

I-795/906. Series 795 and 906 Installation-Ready Knife Gate Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS

I-795/906. Series 795 and 906 Installation-Ready Knife Gate Valves WARNING INSTALLATION AND MAINTENANCE INSTRUCTIONS INSTALLATION AND MAINTENANCE INSTRUCTIONS I-795/906 Series 795 and 906 Installation-Ready Knife Gate Valves HANDWHEEL OPERATOR PNEUMATIC OPERATOR HYDRAULIC OPERATOR WARNING Read and understand all instructions

More information

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

DeZURIK  BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT DeZURIK 20 144" BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT Instruction D10373 April 2017 Instructions These instructions provide information about the 20 (250 F2 model only) and the 24-144 BAW

More information

Installation, Operation, and Maintenance Manual

Installation, Operation, and Maintenance Manual Industrial Process Installation, Operation, and Maintenance Manual Series PBV Plastic Lined Ball Valve Table of Contents Table of Contents Introduction and Safety...2 Safety message levels...2 User health

More information

ENGINEERING STANDARD

ENGINEERING STANDARD PAGE: 1 OF 31 SUBMITTED BY: J. JOSEPH APPROVED BY: ED PEARSON Overview Vendor: Cameron Valves and Measurement 3250 Briarpark Drive Houston, Texas 77041 U.S.A. Telephone: 281-499-8511 Fax: (281) 261-3635

More information

KTM Hindle Series 300 Ultra-Seal two piece metal seated ball valves Installation and Maintenance Instructions

KTM Hindle Series 300 Ultra-Seal two piece metal seated ball valves Installation and Maintenance Instructions Before installation these instructions must be fully read and understood Warning For safety reasons, it is important to take the following precautions before you start work on the valve: 1. Personnel making

More information

INSTALLATION & MAINTENANCE MANUAL

INSTALLATION & MAINTENANCE MANUAL INSTALLATION & MAINTENANCE MANUAL 3-WAY/4-WAY/5-WAY MULTI-PORT BALL VALVES T TEFLON PARTS - 1. Seat x 5 pcs. 2. Joint Gasket x 5 pcs. 3. Retainer Seal x 5 pcs. 4. Thrust Washer x 1 pc. 5. O-Ring x 1 pc

More information

Fabri-Valve XS150. Knife Gate Valve

Fabri-Valve XS150. Knife Gate Valve Fabri-Valve XS150 Knife Gate Valve XS150 XS150 High Performance Knife Gate Valve The Fabri-Valve XS150 High Performance Knife Gate valve features a robust perimeter seal that provides bi-directional bubble

More information

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance OPERATION: (4-2010) The Onyx series CAR-PFO and CAP-PFO pinch valves fail open on loss of air. The simple spring and air bag arrangement drives

More information

COMMERCIAL. BV & BVM Series Installation Instructions 06/29/15

COMMERCIAL. BV & BVM Series Installation Instructions 06/29/15 COMMERCIAL Bray Controls Commercial Division 13788 West Road, Suite 00A Houston, Texas 77041 BCDSales@Bray.com Phone: 1-888-41-79 Fax: 1-888-41-70 www.braycommercialdivision.com BV & BVM Series Installation

More information

DOUBLE OFFSET BUTTERFLY VALVE

DOUBLE OFFSET BUTTERFLY VALVE Flange STD: ASME CLASS 150 LB ASME CLASS 300 LB Temp :210 ~29 Work pressure: VF-91_/92_/93_ 2 ~48 150LB VF-94_/95_/96_ 2 ~24 300LB Pd. date 2011.5 Please read all of these instructions before installing

More information

Gearbox Instruction Manual

Gearbox Instruction Manual Gearbox Instruction Manual Rotork Gears gearbox ranges IW, MOW, MTW, IB, IS, HOB/MPR & HOS/MPR! This manual contains important safety information. Thoroughly read and understand it before installing the

More information

MP and MP Diaphragm and Seal Kits for MP8000 Series Actuators

MP and MP Diaphragm and Seal Kits for MP8000 Series Actuators MP8000-6325 and MP8000-6350 Diaphragm and Seal Kits for MP8000 Series Actuators Contents of the MP8000-6325 Diaphragm and Seal Kit for MP82 and MP83 Actuators One seal, 5/8 in. Internal Diameter (I.D.)

More information

Fig.01 Fig.02 Fig.03. Disassembly & Reassembly Instructions SBV-HP - Page 3

Fig.01 Fig.02 Fig.03. Disassembly & Reassembly Instructions SBV-HP - Page 3 M12A14 WITH FLOATING BACKSEAT 3 Fig.01 Fig.02 Fig.03 Disassembly & Reassembly Instructions SBV-HP - Page 3 M12A14 WITH FLOATING BACKSEAT 3 1. Caution, before any attempt is made to disassemble, verify

More information

Keystone Figures 310/312 K-LOK Butterfly Valves

Keystone Figures 310/312 K-LOK Butterfly Valves 310 - Wafer high performance butterfly valve 312 - Lugged high performance butterfly valve Features General Application High performance applications such as steam, chill water, water, utility lines, gasoline,

More information

INSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE

INSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE INSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE Page 1 of 13 1.1 General CHAPTER 1 - GENERAL INFORMATION This manual contains maintenance instructions with pertinent

More information

DeZURIK MANUAL G-SERIES ACTUATOR USED ON PEF 100% PORT PLUG VALVES

DeZURIK MANUAL G-SERIES ACTUATOR USED ON PEF 100% PORT PLUG VALVES MANUAL G-SERIES ACTUATOR USED ON PEF 100% PORT PLUG VALVES Instruction D10456 August 2012 Manual G-Series Actuator used on Instructions These instructions provide information about Manual G-Series Actuators

More information

ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance

ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance ONYX VALVE CO MODEL DAC-PFO Installation & Maintenance OPERATION: (01-10) The Onyx series DAC-PFO pinch valve fails open on loss of air. This simple spring and air bag arrangement that drives a pair of

More information

Technical changes kept in reserve INSTALLATION, OPERATION & MAINTENANCE MANUAL. 0.- Description Handling Installation...

Technical changes kept in reserve INSTALLATION, OPERATION & MAINTENANCE MANUAL. 0.- Description Handling Installation... INSTALLATION, OPERATION & MAINTENANCE MANUAL INDEX Page 0.- Description...... 2 1.- Handling...... 2 2.- Installation...... 2 3.- Actuators...... 5 4.- Maintenance...... 6 4.1.- Gland packing replacement....

More information

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL

5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL Date: August 2011 / Page 1 of 6 5000/6000 SERIES BALL VALVES INSTALLATION - MAINTENANCE MANUAL DESIGN The design features three piece construction and a free floating ball allowing ease of maintenance

More information

Baumann 24000F Wafer Control Valve

Baumann 24000F Wafer Control Valve Instruction Manual 24000F Valves Baumann 24000F Wafer Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 2 Installation... 3 Air Piping... 3 Disassembly...

More information

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-ADA pinch valve is an open frame valve without housing enclosure and fails last position on loss of air. This actuator

More information

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-PFC pinch valve is an open frame valve without housing enclosure and fails closed on loss of air. The actuator drives

More information

Installation, Operation, and Maintenance Manual Full Port Y-Pattern, Bolted Bonnet, Globe and Check Valves

Installation, Operation, and Maintenance Manual Full Port Y-Pattern, Bolted Bonnet, Globe and Check Valves SMITH VALVES Installation, Operation, and Maintenance Manual Full Port Y-Pattern, Bolted Bonnet, Globe and Check Valves Globe Valve Series: YG80/YG15 Welded Bonnet Globe Valve Series: YG87/YG17 Piston

More information

YOUR GLOBAL FLOW CONTROL PARTNER. BRAY/MCCANNALOK EN High Performance Butterfly Valve Operation and Maintenance Manual

YOUR GLOBAL FLOW CONTROL PARTNER. BRAY/MCCANNALOK EN High Performance Butterfly Valve Operation and Maintenance Manual YOUR GLOBAL FLOW CONTROL PARTNER BRAY/MCCANNALOK EN High Performance Butterfly Valve TABLE OF CONTENTS 1.0 Definition of Terms....................................... 2 2.0 Introduction...........................................

More information

CENTER LINE. INSTALLATION and MAINTENANCE INSTRUCTIONS RESILIENT SEAT BUTTERFLY VALVES MANUAL AND AUTOMATED

CENTER LINE. INSTALLATION and MAINTENANCE INSTRUCTIONS RESILIENT SEAT BUTTERFLY VALVES MANUAL AND AUTOMATED INSTALLATION and MAINTENANCE INSTRUCTIONS MANUAL AND AUTOMATED RESILIENT SEAT BUTTERFLY VALVES CONTENTS Introduction Valve Description... Valve Design Features... Flange and Pipe Schedule Compatibility...

More information

Serie 2003/2013. Three-way Control Valve, mixing/diverting. Wörth am Main. Service. Control Valve Division

Serie 2003/2013. Three-way Control Valve, mixing/diverting. Wörth am Main. Service. Control Valve Division Serie 2003/2013 Three-way Control Valve, mixing/diverting Service Preventive maintenance Preventive maintenance primarily consists of making a regular visual inspection of the valve assembly. This can

More information

Double Offset High Performance Butterfly Valve

Double Offset High Performance Butterfly Valve Double Offset High Performance Butterfly Valve INSTALLATION OPERATION MAINTENANCE APOLLO INTERNATIONAL HIGH PERFORMANCE BFV IOM - Page 2 of 20 TABLE OF CONTENTS INTRODUCTION 3 PRODUCT STORAGE 3 PRODUCT

More information

Knife gate valve HG - Standard

Knife gate valve HG - Standard Knife gate valve HG - Standard V R Data is only for informational purpose. All specifications are subject to change without notice. 1 Knife gate valve HG Stafsjö s knife gate valve HG has excellent flow

More information

Split Body Valves with Bellows Seal Series Globe Valves Series Angle Valves Series Way-Valves

Split Body Valves with Bellows Seal Series Globe Valves Series Angle Valves Series Way-Valves Installation, Operation, Maintenance Instructions Split Body Valves with Bellows Seal Series 025 300 Globe Valves Series 027 300 Angle Valves Series 028 300 3-Way-Valves 1 GENERAL INFORMATION These instructions

More information

Baumann Sanitary Diaphragm Angle and Inline Control Valve

Baumann Sanitary Diaphragm Angle and Inline Control Valve Instruction Manual 84000 Valve Baumann 84000 Sanitary Diaphragm Angle and Inline Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 2 Flow Direction...

More information

Fabri-Valve. CF37 Heavy Duty Knife Gate Valve

Fabri-Valve. CF37 Heavy Duty Knife Gate Valve Fabri-Valve CF37 Heavy Duty Knife Gate Valve CF37 Heavy Duty Knife Gate Valve Fabri-Valve Figures C37 and F37 are some of the most popular knife gate valve configurations. Figure C37 knife gate valves

More information

Series Single seated top guided control valve. Preventive maintenance. Overhauling procedure. Wörth am Main SERVICE NOTE. Control Valve Division

Series Single seated top guided control valve. Preventive maintenance. Overhauling procedure. Wörth am Main SERVICE NOTE. Control Valve Division Series 2000 Single seated top guided control valve Subject to change without notice Fig. 1: Series 2000 valve assembly Preventive maintenance Preventive maintenance consists of making a periodic visual

More information

Operating & Maintenance Manual For Steam Conditioning Valve

Operating & Maintenance Manual For Steam Conditioning Valve For Steam Conditioning Valve 1 Table of Contents 1.0 Introduction 3 2.0 Product description 3 3.0 Safety Instruction 4 4.0 Installation and Commissioning 5 5.0 Valve Disassembly 6 6.0 Maintenance 6 7.0

More information

Baumann Little Scotty Bronze Control Valve

Baumann Little Scotty Bronze Control Valve Instruction Manual 24000 Valve Baumann 24000 Little Scotty Bronze Control Valve Contents Introduction... 1 Scope of Manual... 1 Safety Precautions... 2 Maintenance... 2 Installation... 3 Air Piping...

More information

½" to 4" (DN15 to DN100) LEA31 and LEA33 ANSI Control Valves Installation and Maintenance Instructions

½ to 4 (DN15 to DN100) LEA31 and LEA33 ANSI Control Valves Installation and Maintenance Instructions 00050/1 IM-P0-02 CH Issue 1 ½" to " (DN15 to DN100) LEA1 and LEA ANSI Control Valves Installation and Maintenance Instructions 1. Safety 2. Technical details. Installation and commissioning. Maintenance

More information

310 Wafer high performance butterfly valve 312 Lugged high performance butterfly valve

310 Wafer high performance butterfly valve 312 Lugged high performance butterfly valve 310 Wafer high performance butterfly valve 312 Lugged high performance butterfly valve Features and Benefits Uninterrupted gasket surfaces help eliminate problems associated with seat retaining screws

More information

KEYSTONE FIGURE 79 PNEUMATIC ACTUATOR OPERATING AND MAINTENANCE INSTRUCTIONS

KEYSTONE FIGURE 79 PNEUMATIC ACTUATOR OPERATING AND MAINTENANCE INSTRUCTIONS Operating and Maintenance Instructions for: Figure 79 Pneumatic Actuators (U/E options) Double Acting Actuator 4. If pipelines are hydraulically tested, then the lines should be blown down with high pressure

More information

MK Series - High Performance Butterfly Valves Operation and Maintenance Instructions

MK Series - High Performance Butterfly Valves Operation and Maintenance Instructions COMMERCIAL Bray Controls Commercial Division 13788 West Road, Suite 200A Houston, Texas 77041 BCDSales@Bray.com Phone: 1-888-412-2729 Fax: 1-888-412-2720 www.braycommercialdivision.com MK Series - High

More information

Fisher 657 Diaphragm Actuator Sizes and 87

Fisher 657 Diaphragm Actuator Sizes and 87 Instruction Manual 657 Actuator (30-70 and 87) Fisher 657 Diaphragm Actuator Sizes 30 70 and 87 Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 2 Installation... 3 Mounting

More information

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES Instruction D11023 October 2016 Instructions These instructions provide information about KGN-RSB Knife Gate Valves. They are

More information

Keystone K-LOK Series 36 and 37 High Performance Butterfly Valve Installation and Operation Manual

Keystone K-LOK Series 36 and 37 High Performance Butterfly Valve Installation and Operation Manual Before installation these instructions must be fully read and understood General Suggested installation orientation is with valve shaft horizontal or inclined from vertical. Unless otherwise recommended

More information

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual Before installation these instructions must be fully read and understood Important Before valves are installed or used the following actions are recommended. 1. Valves/parts have to be inspected and thoroughly

More information

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance OPERATION: (4-2010) The Onyx DAO-PFO pinch valve is an open frame valve without housing enclosure and fails open on loss of air. The actuator drives

More information

Before installation these instructions must be fully read and understood

Before installation these instructions must be fully read and understood Before installation these instructions must be fully read and understood Yoke bushing Split gland bushing One-piece body with accessible internals Gland Swing bolts Fully retractable stellite disc Figure

More information

Installation, Operation and Maintenance Manual for the HE Series

Installation, Operation and Maintenance Manual for the HE Series Installation, Operation and Maintenance Manual for the HE Series High Performance Butterfly Valve "Double Offset" CONTENT IOM-HP-100614-1 1. INTRODUCTION 1.1 GENERAL NOTE 1.2 STRUCTURE & TYPE 1.3 OPERATION

More information

Installation Operation Maintenance

Installation Operation Maintenance Installation Operation Maintenance www.challengervalves.com.au 1 QAD#IM1015 REVC 3.10.15 Index 1. INTRODUCTION 3 1.1 Design Features 1.2 Flange and Pipe Compatibility 3 1.3 Operating Pressures and Temperatures

More information

DeZURIK DR 40B ROTARY DIAPHRAGM ACTUATOR

DeZURIK DR 40B ROTARY DIAPHRAGM ACTUATOR DR 40B ROTARY DIAPHRAGM ACTUATOR Instruction D10506 October 2016 Instructions These instructions provide information about s. They are for use by personnel who are responsible for installation, operation

More information

CONTROL VALVES. Installation, Maintenance & Operating Instructions. Read these instructions carefully before installation or servicing.

CONTROL VALVES. Installation, Maintenance & Operating Instructions. Read these instructions carefully before installation or servicing. KOSO HAMMEL DAHL CONTROL VALVES KOSO HAMMEL DAHL 253 Pleasant Street West Bridgewater, MA 02379 tel: 774.517.5300 fax: 774.517.5230 www.hammeldahl.com Installation, Maintenance & Operating Instructions

More information

W-K-M Model MA-1 DynaCentric Butterfly Valve

W-K-M Model MA-1 DynaCentric Butterfly Valve Page 1 of 12 W-K-M Model MA-1 DynaCentric Butterfly Valve Page 2 of 12 Published January 2003 W-K-M and DynaCentric are trademarks of Cooper Cameron Corporation Cooper Cameron Corporation, Cooper Cameron

More information

DeZURIK KGC-MD KNIFE GATE VALVES

DeZURIK KGC-MD KNIFE GATE VALVES KGC-MD KNIFE GATE VALVES Instruction D11032 February 2018 Instructions These instructions are intended for personnel who are responsible for the installation, operation and maintenance of your KGC-MD knife

More information

Fisher 3024C Diaphragm Actuator

Fisher 3024C Diaphragm Actuator Instruction Manual 3024C Actuator Fisher 3024C Diaphragm Actuator Contents Introduction... 1 Scope of Manual... 1 Description... 2 Specifications... 3 Installation... 5 Mounting the Actuator on the Valve...

More information

IOM-CleanFLOW TM. CleanFLOW Series Ball Valves. SV F Flow Controls I N C O R P O R A T E D

IOM-CleanFLOW TM. CleanFLOW Series Ball Valves. SV F Flow Controls I N C O R P O R A T E D !!!CAUTION! Safety Precautions!!! Before removing valve from pipeline NOTE that: Media flowing through a valve may be corrosive, toxic, flammable, a contaminant or harmful nature. Where there is evidence

More information

Recommended spare parts are listed on the assembly drawing. These parts should be stocked to minimize downtime.

Recommended spare parts are listed on the assembly drawing. These parts should be stocked to minimize downtime. Instruction D10411 July 2018 Instructions These instructions are intended for personnel who are responsible for the installation, operation and maintenance of your KGC knife gate valve, including models

More information

Keystone K-LOK Series 360/362 and 370/372 Installation, Operation, Maintenance and Troubleshooting

Keystone K-LOK Series 360/362 and 370/372 Installation, Operation, Maintenance and Troubleshooting Before installation these instructions must be fully read and understood 4. Confirm that the materials of construction listed on the valve nameplate are appropriate for the service intended and are as

More information

OPERATION AND MAINTENANCE MANUAL 2-66 SERIES 2500 RESILIENT WEDGE GATE VALVE

OPERATION AND MAINTENANCE MANUAL 2-66 SERIES 2500 RESILIENT WEDGE GATE VALVE OPERATION AND MAINTENANCE MANUAL 2-66 SERIES 2500 RESILIENT WEDGE GATE VALVE INDEX SERIES 2500 DUCTILE IRON RESILIENT WEDGE GATE VALVE OPERATION and MAINTENANCE MANUAL. OPERATION AND MAINTENANCE Operation,

More information

DeZURIK 2-24 (50-600mm) KGC ES or HD KNIFE GATE VALVES

DeZURIK 2-24 (50-600mm) KGC ES or HD KNIFE GATE VALVES 2-24 (50-600mm) KGC ES or HD KNIFE GATE VALVES Instruction D10411 March 2017 Instructions These instructions are intended for personnel who are responsible for the installation, operation and maintenance

More information

Keystone K-LOK Series 360/362 and 370/372 Installation, Operation, Maintenance and Troubleshooting

Keystone K-LOK Series 360/362 and 370/372 Installation, Operation, Maintenance and Troubleshooting Before installation these instructions must be fully read and understood 4. Confirm that the materials of construction listed on the valve nameplate are appropriate for the service intended and are as

More information

GT-200 GATE VALVES PN16, Screwed end

GT-200 GATE VALVES PN16, Screwed end Document No. : MD-QO-04-281 Date : 2009/07 /17 Version : 1.0 GT-200 GATE VALVES PN16, Screwed end USER MANUAL Modentic Industrial Corporation 14F-1,No.57Taya Rd.,Taichung,Taiwan,R.O.C. Email:modentic@ms9.hinet.net

More information

Power-Seal High Performance Butterfly Valve: Series P1 Installation & Maintenance Manual

Power-Seal High Performance Butterfly Valve: Series P1 Installation & Maintenance Manual CAUTION: 1. For your safety read this manual completely before installation or servicing. 2. Before installing or servicing, please ensure the line pressure has been relieved, and any hazardous fluids

More information

Fisher 2052 Diaphragm Rotary Actuator

Fisher 2052 Diaphragm Rotary Actuator Instruction Manual 2052 Actuator Fisher 2052 Diaphragm Rotary Actuator Contents Introduction... 1 Scope of Manual... 1 Description... 1 Specifications... 4 Installation... 4 Actuator Mounting and Changing

More information

INSTALLATION, OPERATION & MAINTENANCE MANUAL

INSTALLATION, OPERATION & MAINTENANCE MANUAL Rack & Pinion Pneumatic Actuators INSTALLATION, OPERATION & MAINTENANCE MANUAL QSM, Inc. 127 Village Lane Easley, SC 29642 U.S.A. Ph: (864) 605-0150 Fax: (864) 605-0830 www.tru-flo.com TABLE OF CONTENTS

More information

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com W D0446-A 4/1/05 1

PO Box 645, Stockton, Missouri, FAX superiorgearbox.com W D0446-A 4/1/05 1 W000-7000-D0446-A 4/1/05 1 SAFETY PRECAUTIONS CAUTION Please read this entire document prior to operating the gear drive. Gear drive failure and / or injury to operators may be caused by improper installation,

More information

FORGED HIGH PRESSURE BONNETLESS. ASME CLASSES: Sizes: 1 2 4" ( mm) U.S. Patent # Patented Easy Maintenance!

FORGED HIGH PRESSURE BONNETLESS. ASME CLASSES: Sizes: 1 2 4 ( mm) U.S. Patent # Patented Easy Maintenance! FORGED HIGH PRESSURE BONNETLESS ASME CLASSES: 1690 4500 Sizes: 1 2 4" (15 100 mm) U.S. Patent # 4356832 Patented Easy Maintenance! PROFILE Velan is one of the world's leading manufacturers of industrial

More information

F8/FB8 Series Ball Valves IOM-F8/FB8

F8/FB8 Series Ball Valves IOM-F8/FB8 !!!CAUTION! Safety Precautions!!! Before removing valve from pipeline NOTE that: Media flowing through a valve may be corrosive, toxic, flammable, or a contaminant of harmful nature. Where there is evidence

More information

Model DF233 Control Valve

Model DF233 Control Valve Figure 1 DF233 Control Valve TABLE OF CONTENTS Introduction 2 Body and Packing Reassembly 7 Specifications 3 Fail Closed Actuator Reassembly 8 Valve Sizes 3 Fail Open Actuator Reassembly 9 Unpacking 4

More information

Keystone Figure V11 Butterfly Valve Installation, Operation and Maintenance Manual

Keystone Figure V11 Butterfly Valve Installation, Operation and Maintenance Manual Please read these instructions carefully - indicates that it may lead to injuries or damages on the properties. Warning - indicates that it may lead human body to serious injuries. Danger - indicates that

More information