BWT Infinity A DIN 20mm.972 L/s DIN 25mm L/s DIN 32mm L/s
|
|
- Emil Phillips
- 6 years ago
- Views:
Transcription
1 HARVESTED RAINWATER POST FILTRATION & UV DISINFECTION OPTIONS 0.50 L/s 1.40 L/s Automatic Post Filtration BWT Infinity A DIN 20mm.972 L/s DIN 25mm L/s DIN 32mm L/s Install one or two BWT Infinity A automatic backwash filter DIN.. Electronic timer with hour-day-week-month settings depending on the quality of the water, 90 micron anti-scale screen and associated connection module with male/male threaded unions. Each filter is capable of handling a peak demand flow rate of..l/s (Refer above) * Install isolation valves each side of the filters * Tundish to floor-waste or stormwater * 240V 10Amp Gpo within 1 meter of the installed filters above the splash Line of the tundish * Install in a plant room or under all weather sun-proof, vandal-proof, well 1
2 Final bag filtration 1, 5, 10, 25, 50 microns 0.50L/s 1.40 L/s Install (2) two WFC X100B-FSIX100 polypropylene bag filter housing with legs; 2 inlet / outlet ports Supply only: (4) four WFCBPONG25X01-25 micron nominal polypropylene filter bags with polytec seal (two are spares) Install on a manifold in parallel Isolation valves each of the installed bag filter housings Pressure gauges each side of the filter housings Floor waste in vicinity of housing with fall to drain housings during filter bag change (Refer to attached installation & technical data) 2
3 BWT UV disinfection systems where water will come in contact with humans Rainwater UV disinfection systems 0.50 L/s 1.50 L/s Install: (1) one or two BWT Bewades 80W80/11 LC 316 S/S ultra violet disinfection systems with inbuilt agitators to minimise soiling of the quartz sleeve. Technical data: Nominal connection width DIN 32mm Max vol. flow 400 J/m2 at T 100 = 70% transmission 4.50M 3 h Max op pressure 10 bar Min/Max ambient water temp. 5/40 0 C Emitter power W 80 Power 230/50 V/Hz Degree of protection IP 54 UV chamber 316 Ti S/S BMS connections for power & lamp failure Yes Inbuilt turbulators for agitation and even flow of water Yes Isolation valves each side of the install UV chamber Bypass valve & associated pipe-work if 1 system is installed otherwise a second unit in parallel acts as duty standby 240V 15 Amp Gpo with 1 meter of the installed UV system Fall to floor-waste in vicinity of UV chamber to drain during service Install in plant room or under all weather, sun-proof, vandal-proof well 3
4 HARVESTED RAINWATER POST & FINAL FILTRATION & UV DISINFECTION OPTIONS 2.50 L/s 3.05 L/s Automatic Post Filtration BWT Infinity A DIN 40mm 2.50 L/s DIN 50mm 3.05 L/s Install one or two BWT Infinity A automatic backwash filter DIN. Electronic timer with hour-day-week-month settings depending on the quality of the water, 90 micron anti-scale screen and associated connection module with male/male threaded unions. Each filter is capable of handling a peak demand flow rate of.l/s (Refer above) M * Install isolation valves each side of the filters * Tundish to floor-waste or stormwater * 240V 10Amp Gpo within 1 meter of the installed filters above the splash Line of the tundish * Install in a plant room or under all weather sun-proof, vandal-proof, well 4
5 Final bag filtration 1, 5, 10, 25, 50 microns 2.50L/s 3.05 L/s Install (2) two WFC X100B-FSIX100 polypropylene bag filter housing with legs; 2 inlet / outlet ports Supply only: (4) four WFC25X01-25 micron nominal polypropylene filter bags with polytec seal (two are spares) Install on a manifold in parallel Isolation valves each of the installed bag filter housings Pressure gauges each side of the filter housings Floor waste in vicinity of housing with fall to drain housings during filter bag change (Refer to attached installation & technical data) 5
6 BWT UV disinfection systems (where rain-water is in contact with humans) 2.50L/s 3.05 L/s Install: two BWT Bewades 100W100/11 LC 316 S/S ultra violet disinfection system on a manifold in parallel. Technical data: Nominal connection width DIN 50mm Max vol. flow 400 J/m2 at T 100 = 70% transmission 7.00M 3 h Max op pressure 10 bar Min/Max ambient water temp. 5/40 0 C Emitter power W 100 Power 230/50 V/Hz BMS connections for power & lamp failure Yes Inbuilt turbulators for agitation and even flow of water Yes Degree of protection IP 54 UV chamber 316 Ti S/S Isolation valves each side of the install UV chamber Bypass valve & associated pipe-work if 1 system is installed otherwise a second unit in parallel acts as duty standby 240V 15 Amp Gpo with 1 meter of the installed UV system Fall to floor-waste in vicinity of UV chamber to drain during service Install in plant room or under all weather, sun-proof, vandal-proof well 6
7 BWT UV disinfection systems (where rain-water is in contact with humans) 2.80L/s 5.50 L/s Install: (2) two BWT Bewades 200W200/11 LC 316 S/S ultra violet disinfection systems on a manifold in parallel Technical data: Nominal connection width DIN 50mm Max vol. flow 400 J/m2 at T 100 = 70% transmission 10.00M 3 h Max op pressure 10 bar Min/Max ambient water temp. 5/40 0 C Emitter power W 200 Power 230/50 V/Hz BMS connections for power & lamp failure Yes Inbuilt turbulators for agitation and even flow of water Yes Degree of protection IP 54 UV chamber 316 Ti S/S Install UV chambers on a manifold in parallel Isolation valves each side of the install UV chamber Bypass valve & associated pipe-work if 1 system is installed otherwise a second unit in parallel acts as duty standby 240V 15 Amp Gpo with 1 meter of the installed UV system Fall to floor-waste in vicinity of UV chamber to drain during service Install in plant room or under all weather, sun-proof, vandal-proof well 7
8 HARVESTED RAINWATER POST & FINAL FILTRATION & UV DISINFECTION OPTIONS 6.00 L/s L/s BWT RF Multipur A DIN 65mm 6.00 L/s BWT RF Multipur A DIN 80mm L/s * Install filters on a manifold in parallel * Isolation valves each side of the filters * Tundish to floor-waste or stormwater * 240V 10Amp Gpo within 1 meter of the installed filters above the splash Line of the tundish * Install in a plant room or under all weather sun-proof, vandal-proof, well (Refer attached installation & technical data) 8
9 Final bag filtration 1, 10, 25, 50 microns Duty 2.50 L/s L/s Filter bag housings: Install: (2) two or three WFC BFS-2C BSP-316L food quality stainless steel bag filter housings with band clamp closure, 2 BSP inlet/outlet ports that accept P2 size (7 OD x 32 long) filter bags. If flow rates are above 7.00 L/s consider a third or fourth system manifolded in parallel to share the load. Filter bags: Supply only: (4) four WFC BPG-25-2SS-25 micron nominal polypropylene P2 size filter bags with 316 stainless steel rings. (Two cartridges are spares) Install isolation valves each of the installed bag filter housings Install on a manifold in parallel Install Pressure gauges each side of the filter housings Install pressure differential switches across each housing with voltage free connections to BMS system to identify pressure due to blockages of the bag filters Floor waste in vicinity of housing with fall to drain housings during filter bag change 9
10 BWT UV disinfection systems (where rain-water is in contact with humans) 6.00 L/s L/s Install (2) Two UV-disinfection units, manufacture BWT Type Bewades 240W80/22EU UV-disinfection units for microbiological control for drinking and process water - Suitable for wide transmission range (10-90% / 10 cm) - Optimum hydraulic design with Internal mixing devices for generation of turbulence for uniform UV-treatment and advanced disinfection performance - Power socket unit - Calibrated, UVC-selective high quality UV-sensor - Low-pressure UV-lamps with very long life time up to h - UV reaction chamber made of high grade stainless steel 316Ti - Integrated ballast unit - High quality quartz sleeves with expected life time of 3 years Microprocessor controlled unit "UV-Control II" with the following features: - measuring of radiation performance with digital display of UV intensity (% or W/mý) and 0/ ma output for BMS - LED indication for power on, operation and failure - Hours run meter and counter for lamp activations - Supervision of each lamp with local and remote operation/failure indication and safety shut down - Adjustable warning and shut down threshold for low UV-intensity with local and remote alarm for BMS - Connection for external/remote control - Connections for: Shut-off valve Rinsing valve Thermostat Flow control device - Automatic rinsing can be initiated Time, temperature or flow controlled - Local and remote alarm (potential free contact) for failure indication available 10
11 Technical data: Connection width 80mm Nominal flow rate at transmission of 70 %/10 cm and UV-dose of 40 mws/cmý m3/h 22 (After h lamp life time) Nominal pressure max. bar 10 Water temperature min./max. øc. 5/30 Ambient temperature min./max.øc 5/40 Radiator performance W 200 Expect. Lamp life time h UVC-performance W 63 Power supply V/Hz 230/50 Power consumption W approx 260 Number of radiators 3 Dimensions Width mm 219 Height mm 1165 * Free space above UV system for lamp replacement: mm
UV sterilizers and spare parts
UV sterilizers and spare parts WATER TREATMENT COMPONENTS Engineered by Eurotrol S.p.A. Residential U.V. Sterilizers Inox monolamp U.V. sterilizer of close construction in AISI 304 polished material for
More informationWatertreatment. Landbased Farming. Weedfilter. Catvis WATER I NTAKE R ECIRCULATION S YSTEM
Weeds Drum Cartridge UV-unit WATER I NTAKE Screen Pump Weed Drum UV-unit Climate control H ATCHERY N URSERY B ROODSTOCK O NGROWING Oxygen reactor Denitrification Control unit R ECIRCULATION S YSTEM Ozonation
More informationHydrosafe - Model HSFS
Hydrosafe - Model HSFS Whole House Filtration and Water Treatment Triple-Treat Protection Three-In-One Technology The innovative HydroSafe filtration system incorporates three technologies in one unit
More informationGENO -MX 1" - MX DN 100 backwash filter. Intended use. Scope of supply. Function. Structure
Subject to modifications TD2-AM001en_004 Edition June 2017 GENO -MX 1" - MX DN 100 backwash filter Intended use The GENO -MXA backwash filters are suitable for the following sectors: Filtration of drinking
More informationTECHNICAL DESCRIPTION
TECHNICAL DESCRIPTION Of PROJECT : Yacht Hotel Ship SHIPYARD : Boustead Naval Shipyard SHIPOWNER : Sunborn Internation PUMP CAPACITY : 250m3/hr 1 set Skid Type DATE : Apr. 20th, 2011 PANASIA CO., LTD.
More informationEngineered to Higher Standards
Engineered to Higher Standards G, H, J, K & Pro50 www.uvmax.com Engineered to Higher Standards The technology and care that goes into the development of our products is of the highest standards. Our UV
More informationECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES
ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES TECHNICAL AND INSTALLATION DOCUMENTATION STOKVIS ENERGY SYSTEMS UNIT 34 CENTRAL PARK ESTATE 34 CENTRAL PARK ESTATE WEST
More informationTECHNICAL DESCRIPTION
TECHNICAL DESCRIPTION Of PUMP CAPACITY : 700 m3/h x 1 I. SYSTEM GENERAL PANASIA s GloEn-Patrol Type approved by administration in compliance with the Guidelines for approval of (G8) of Res. MEPC.125(53)
More informationEXPERTS IN ULTRAVIOLET DISINFECTION
EXPERTS IN ULTRAVIOLET DISINFECTION www.atguv.com ECL RANGE MEDIUM PRESSURE UV SYSTEMS ECL RANGE - MEDIUM PRESSURE UV www.atguv.com THE IN-LINE UV CHAMBER DESIGN OPTIMISES FLOW HYDRAULICS, PROVIDING A
More informationSOLICITATION C INSTALLATION AND MAINTENANCE OF POTABLE WATER FILTRATION SYSTEMS THROUGHOUT THE STATE OF FLORIDA QUESTIONS AND ANSWER
SOLICITATION 2015013C INSTALLATION AND MAINTENANCE OF POTABLE WATER FILTRATION SYSTEMS THROUGHOUT THE STATE OF FLORIDA QUESTIONS AND ANSWER The following questions have been submitted: 1. Could you tell
More informationREVISED ATM72 Auto Transfer Module
Capricorn Controls DA01ATM1-1 Data & Application Note Page 1 of 8 REVISED - - - ATM72 Auto Transfer Module Genset Controls - Timers - Monitors - Trips - Battery Charging - Spares & Accessories - Custom
More informationULTRAVIOLET WATER DISINFECTION SYSTEM OPERATION & MAINTENANCE MANUAL
ULTRAVIOLET WATER DISINFECTION SYSTEM OPERATION & MAINTENANCE MANUAL GUV-SHIELD, GUV-SHIELD-MAN SERIES UV Systems Model numbers: GUV-7 GUV-SHIELD-7 GUV-SHIELD-7-MAN GUV-SHIELD-10 GUV-SHIELD-10-MAN GUV-SHIELD-15
More informationExpert tip: UNPARALLELED PROTECTION AND VERSATILITY UNDERGROUND IRRIGATION PROGRAMMABLE SOLENOID CONTROL UNIT 1 F. PROGRAMMABLE SOLENOID VALVE.
Masters of Water PROGRAMMABLE SOLENOID Expert tip: The new detachable control units have been redesigned to meet IP 68 standard: the highest level of filter against water, grit and dirt. The new units
More informationUVMAX Light Commercial Series Model description weight NOTES
UVMAX Light Commercial Series 80 GPM K - 80 gpm disinfection, with 2 MNPT inlet/outlet connections on a 316L SS reactor. System comes equipped with an LPHO amalgam UV lamp, and CoolTouch fan to reduce
More informationAQUA2000 From O3PURE
AQUA2000 From O3PURE OWNER S MANUAL INCLUDES: RESTRICTIONS INSTALLATION OPERATION MAINTENANNCE CHANGING THE FILTER CHANGING THE UV LAMP SPECIFICATIONS WARRANTY ADVANCED WATER TREATMENT SYSTEMS CAUTION:
More information1.0 F300S Ultraviolet Flood Exposure System
1.0 F300S Ultraviolet Flood Exposure System Timer ON/OFF switch Timer Handle for opening the chamber UV lamp power supply 1.1 Introduction Figure 1: F300S Ultraviolet Flood Exposure System. F300S is a
More informationDIFFERENTIAL PRESSURE BATTERY CHARGERS
DIFFERENTIAL PRESSURE BATTERY CHARGERS CONVERTING PIPELINE ENERGY TO BATTERY POWER Free Uninterruptible Power 24/7 ISO 9001:2008 Certified Quality System 10-20 Watt Units Available POWER SYSTEMS 12 or
More information... PureLine PQ. Technical Specification. PureLine PQ (Disinfection) Models PQ PQ UV Chamber. Cabinet
PureLine PQ PureLine PQ (Disinfection) Models PQ0200 - PQ 1100... Technical Specification UV Chamber Material: Internal finish: Stainless steel 316L
More informationINSTALLATION AND USER INSTRUCTIONS
Ultraviolet Sterilizers INSTALLATION AND USER INSTRUCTIONS Document applicable to all models 1000 & 1000 eco 2000 & TIO-UV & 2000 eco TIO-UV-eco 10000 1 UV CINTROPUR: Applications p.2 2 Design p.2 3 Installation
More informationGE.VO.360/325.SS+0_all
. Generating Set Diesel +0_all Standard Equipment and features Canopy - Soundproofing Engine Soundproof canopy IP 32 monoblock Engine heater 230 V Polyester class1 soundproofing High coolant temperature
More informationCytotoxic Safety Cabinets ENVAIR eco safe Plus
Cytotoxic Safety Cabinets ENVAIR eco safe Plus Class Cytotoxic Standard Width (m) II Safety EN 12469 0.9 / 1.2 Cabinet DIN 12980 1.5 / 1.8 Clean technology for a clean environment ENVAIR eco safe Plus
More informationIntroduction Advantages of cooperating with Our service - our conditions Our standard central control valve
Introduction Advantages of cooperating with Our service - our conditions Our standard central control valve Gravel-Filter Deferrisation Systems Pressure filter EKF, made of stainless steel (V4A) Pressureless
More informationTEFEN FLOW & DOSING TECHNOLOGIES
DOSING PUMPS Agriculture Livestock Industry Order from irrigationglobal.com mixrite dos injectors for livestock medicators. Tefen TEFEN FLOW & DOSING TECHNOLOGIES contact: irrigationglobal.com for orders
More informationWEDECO DLR SERIES ULTRAVIOLET WATER DISINFECTION UNIT INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-AP SERIES NO'S
INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-AP WEDECO DLR SERIES ULTRAVIOLET WATER DISINFECTION UNIT SERIES NO'S 1 2 4 7 Sold by: Manufactured by: WEDECO Ideal Horizons, Inc. 3520 Westinghouse
More informationWARCO CHEMAG SERIES GH FILTERS
WARCO CHEMAG SERIES GH FILTERS High Performance Pleated & Bag Type Filtration Systems INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Thank you for your purchase of a WARCO Series GH Filtration System.
More informationCooling Tower Control & Dosing Bleed, Inhibitor, Timed Biocide, ORP
DIGI-AB2RX2A-P DIGI-AB2RX2A-P-CABG DIGI-AB2RX2A-P-X/3S DIGI-AB2RX2A-P-X/3S-CABG DIGI-A2RX2A-P DIGI-A2RX2A-P-CABG DIGICHEM -ORP-XP2 Controller with Inhibitor, Non-oxidising Biocide & Chlorine Peristaltic
More informationAGRICULTURE HORTICULTURE GREENHOUSE
AGRICULTURE HORTICULTURE GREENHOUSE Fertilizer & Chemical injectors are water driven only, with no ( other energy required I n j e c t o r s A step up from Different Models Application Fertigation Water
More informationSafeFAST Classic. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.
SafeFAST Classic Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE. OUR COMMITMENTS New technologies for a low environmental impact Fully aware that our choices of today
More informationARKAL FILTERS CATALOGUE
ARKAL FILTERS CATALOGUE Content DISC FILTERS - TECHNOLOGY 4 Automatic Filters Compact 6 2" Compact All Plastic 8 Opal 10 2" Poly Battery 12 Crystal 14 3" Poly Battery 16 Galaxy 18 Galaxy Polymer 20 Manual
More informationORION. Safety Class 2 100% exhaust. ALMOST Rocket Science
LaboGene SCANdinavian by design. ORION ALMOST Rocket Science Safety Class 2 100% exhaust Probably the best Class 2 with 100% exhaust for work with animal handling or high concentrations of organic solvents
More informationMonobloc and Sectional Directional Control Valves
Monobloc and Sectional Directional Control Valves motion and progress 1/220 6 Monobloc directional control valves Contents 6.1 General specifications 66 6.2 Dimensional data 67 6.3 Performances curves
More informationPURE WATER. Installation, Operation and Maintenance Manual. 3-Stage Under Counter Filtration with UV Model PWSYS-UV-3STG. Important.
Installation, Operation and Maintenance Manual 3-Stage Under Counter Filtration with UV Model PWSYS-UV-3STG IOM-WQ-PWSYS-UV-3STG PURE WATER Important Please read the entire manual before proceeding with
More informationUV-AIRE AIR PURIFYING SYSTEM
UV-AIRE AIR PURIFYING SYSTEM Model: UV-16/24 The UV-Aire unit is designed to emit powerful UVC Band light rays, which sterilize and reduce airborne microorganisms as they pass through a heating or air
More informationWL250 TOWER DRAWING AND PARTS LIST
WL250 TOWER DRAWING AND PARTS LIST Yellow = Consumables Green = Recommended spare parts WL250 Manual Page 27 Revision: 4 3 2018 No WLCP Part No. Consumables Description Part No Cold Only Hot & Cold Stocked?
More informationPlanning Manual Passion 300-S. Passion 300-S. Super Power Twin Power. Contents
Planning Manual EN 60335-2-27:2003+A1:2009 The Optimized Performance Concept of the Passion-S series gives the best tanning results under the 0.3 Standard, without an increased risk of sunburn. This result
More informationExcel AD Electromagnetic dosing pump
Flow rate Up to 7.6 l/h Pressure Up to 17.3 bar Liquid ends Acrylic, stainless steel, PP, PVC, PVDF, designed for viscous products, designed for degassing products LCD user interface with display of the
More informationINSTRUMENTATION & CONTROL
Irrigation Controller.................... 172 Window Controller.................... 174 Water Meter Controller.................. 176 Digital Level Switch.................... 177 Filtration Controller Set..................
More informationSPARE PARTS PRICE LIST SEAKEEPER SERIES
SPARE PARTS PRICE LIST SEAKEEPER SERIES UPDATED 3.6.2018 COMMON PARTS SECTION PAGE NUMBER ELECTRONIC SUB-ASSEMBLY 6 SEAKEEPER 3 SECTION PAGE NUMBER ELECTRONIC SUB-ASSEMBLY 7 BRAKE SUB-SYSTEM 7 COOLING
More informationLubrication Systems. Section 26
Lubrication Systems Section 26 26-1 INFORMATION - SYSTEMS The Lincoln QuickLub is an automated and centralised lubrication system that can improve productivity and extend the service life of your plant.
More informationLK Manifold Shunt VS2
LK Manifold Shunt VS2 Design LK Manifold Shunt VS2 is a shunt unit with a two way control valve used in systems with a primary pump. The shunt unit is mountable from both the left and right of LK Manifolds.
More informationUltraviolet Sterilization System Installation Instructions & Owner s Manual
Your best choice in Ultraviolet Sterilization RoHS COMPLIANT Ultraviolet Sterilization System Installation Instructions & Owner s Manual For models: UV-1, UV-2, UV-6, UV-8C, UV-12C, UV-24B UV-100B Table
More informationD M S 760 C01 A A 1 1
CONTENTS Description Features Options Available Selection Method Product Data Cooling Performance Data (85 F Ambient Cooling Performance Data (95 F Ambient) Cooling Performance Data (105 F Ambient)..............................
More informationEach pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.
General 1 Model MS 9-2-60 expandable/modular duplex central vacuum system consisting of two Becker or approved equivalent VT4.25 vacuum pumps mounted on a common skid with expandable automatic alternating
More informationLaboratory Equipment MICROBIOLOGICAL SAFETY CABINETS ENVAIR ECO SAFE COMFORT PLUS CLASS II MICROBIOLOGICAL SAFETY CABINET.
MICROBIOLOGICAL SAFETY CABINETS CLASS II MICROBIOLOGICAL SAFETY CABINET CLEAN TECHNOLOGY FOR A CLEAN ENVIRONMENT - THE CLEAN GENERATION Envair eco safe Comfort Plus Safety Cabinets belong to the latest
More informationCONTROLLERS & SPECIAL VALVES
CONTROLLERS & SPECIAL VALVES G75-C 1, 2 & 4 Valve Controllers.... 70 G75-C-1W & 1W+ Window Controller... 72 G75-DP Differential Pressure Switch.....................................................................
More informationIndustrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized
RATINGS 400 V - 50 Hz Standby kva 3300 KWe 2640 Prime kva 3000 KWe 2400 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator set,
More informationEnvair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets
Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets Envair SCS Evo Comfort + Class II Microbiological Safety Cabinets set the benchmark in laminar airflow technology, creating a new generation
More informationHeating oven with mechanical control
ED series 23 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C. Thanks to the
More informationModel: UV-16R/24 READ THESE INSTRUCTIONS CAREFULLY AND COMPLETELY BEFORE PROCEEDING WITH THE INSTALLATION.
U V - AIRE AIR PURIFYING S YSTEM Model: UV-16R/24 ITEMS INCLUDED IN KIT: 1-24Volt UV-Aire Ballast Assembly 1-Mounting Base 1-Ultraviolet Lamp 6-Sheet Metal Mounting Screws 1-Instruction Sheet 1-Fiberglass
More informationDosing Pump Operational Manual
Chemical Dosing Specialists Dosing Pump Operational Manual Pump Range WMPSP0110 - WMPSP0408 - WMPSP0607 - WMPSP0805 - WMPSP1204 - WMPSP1502 - WMPSP2001 1- Product Introduction 2 1.1 Product Overview 2
More informationPower consumption Operation At rest Wire sizing. Auxiliary switch. EMC Low-voltage directive. Non-operating temperature range 40...
echnical data sheet SM24P-S Robustline damper actuator for operating air dampers in industrial plants and in the technical building installations For air dampers up to approx..2 m 2 orque 8 Nm Nominal
More informationMPD Series. Medium Pressure Duplex
Medium Pressure Duplex 89 Applications of MPD Circulating Lube Oil Systems Power Generation Control Systems Steel Mill Control Systems Pulp & Paper Control Systems Test Stands Automotive Stamping Presses
More informationFabricated Duplex Strainers
Applications Chemical Industry Metals & Mining Process Industry Water & Waste Water Power Industry Pulp & Paper Oil & Gas Fabricated Duplex Strainers Pressures to 1480 PSIG Temperatures to 800ºF FEATURES
More informationVALVES WITH UV ELECTRIC ACTUATOR
505-507 VALVES WITH UV ELECTRIC ACTUATOR CHARACTERISTICS The 505+UV and 507+UV cast iron ball valves are dedicated to the automatic opening/shut-off of pipes carrying low pressure unloaded common fluids.
More informationCrime-lite 2. a new and improved range of forensic light sources
FF(UK):08/11/A Crime-lite 2 a new and improved range of forensic light sources Higher intensity Constant light output Eight wavelengths including UV Uniform beam Extended run time Rugged and splash proof
More informationTreatment Chamber. Control System
The ECOFLO II is the latest, state-of-the-art UV treatment system. Our objective for the product was simple to be the best on the market, no compromise. The ECOFLO II offers the flexibility of a horizontal
More informationElectronic Control Valves
131 Series (Full Internal Port) 631 Series (Reduced Internal Port) MODEL Electronic Control Valves Model 131-01/631-01 Simple Proven Design Quality Solenoid Pilot Controls Ideal For SCADA Systems Multi-Function
More informationEach pump shall be equipped with carbon/graphite vanes. A vacuum relief valve shall be incorporated into the design of the pump.
1 General Model MS300-4-530 expandable/modular central vacuum system consisting of 4 Becker or approved equivalent VTLF2.250 vacuum pumps mounted on a common skid with expandable automatic alternating
More informationMPD Series. Medium Pressure Duplex
Medium Pressure Duplex 81 Applications of MPD Circulating Lube Oil Systems Power Generation Control Systems Steel Mill Control Systems Pulp & Paper Control Systems Test Stands Automotive Stamping Presses
More informationDETAILED EQUIPMENT SPECIFICATION MRO-4 SERIES REVERSE OSMOSIS SYSTEMS
5356 Hillside Avenue Indianapolis, IN 46220 P: +1 888-56-Water (569-2837) F: +1 317-255-4727 info@nancrede.com www.nancrede.com DETAILED EQUIPMENT SPECIFICATION MRO-4 SERIES REVERSE OSMOSIS SYSTEMS 1.0
More informationROTA PULSE FLOW SENSOR Slip Insertion Paddlewheel (with inductive coil pulse output & built in op-amp circuit)
FEATURES ROTA PULSE FLOW SENSOR Slip Insertion Paddlewheel (with inductive coil pulse output & built in op-amp circuit) DATASHEET ± 2.5% accuracy @ velocity range 0.5 to 8.5 m/sec. ± 1.5% accuracy over
More informationElectrical panels TECHNICAL INFORMATION 104 ELECTRICAL PANELS 105 PROTECTION OF ELECTRICAL COMPONENTS 107 ELECTRICAL PANEL ACCESSORIES 110
04 ELECTRICAL PANELS Electrical panels TECHNICAL INFORMATION 104 ELECTRICAL PANELS 105 PROTECTION OF ELECTRICAL COMPONENTS 107 ELECTRICAL PANEL ACCESSORIES 110 103 TECHNICAL INFORMATION Technical information
More informationAGRICULTURE HORTICULTURE GREENHOUSE
AGRICULTURE HORTICULTURE GREENHOUSE TM TM TM Fertilizer ( Injectors A step up from & Chemical injectors are water driven only, with no other energy required Application Fertigation Water Treatment Supplementation
More informationManual Kinematic Viscosity Bath Tamson TV12
Manual Kinematic Viscosity Bath Tamson Rev 1.05 1 Viscosity Business Today Testing kerosene Testing diesel Testing lubricants Testing fuel oils Testing residues Testing bituminous or asphalt samples Testing
More informationInstallation, Operation and Maintenance Manual
Installation, Operation and Maintenance Manual IOM-WQ-SmartStream-A 254 Nanometer Germicidal UV Disinfection Systems Models WA002 WA006 WA008 WA012 SmartStream UV Chemical Free Disinfection of Water Read
More informationIndustrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized
RATINGS 400 V - 50 Hz Standby kva 2250 KWe 1800 Prime kva 2045 KWe 1636 Benefits & features premium quality provides one source responsibility for the generating system and accessories The generator set,
More informationIndirect evaporative air conditioning 100% outside air FACTORY INSTALLATION (CW-160)
FACTORY INSTALLATION (CW-160) Indirect evaporative air conditioning 100% outside air About Climate Wizard Climate Wizard s unique indirect evaporative heat exchange core provides hyper-efficient cooling
More informationThe pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.
General Model MS150-4-150 expandable/modular central vacuum system consisting of 4 Becker or approved equivalent KVX3.140-400 vacuum pumps mounted on a common skid with expandable automatic alternating
More informationElectric FIP Type TKD ABS 3 Way Ball Valve
Electric actuator fitted via EasyFit-F kit Sizes: DN15-50 D20-6 1/2-2 Main JCS Smart electric actuator features: LED light for continual visual actuator status feedback. Fully weatherproof smart industrial
More informationFLUID TRANSFER SECTION 1
SECTION 1 FLUID TRANSFER HF10 FILTRATION UNIT...2 SUPER DELUXE PORTABLE FILTRATION UNIT...2 VISCOMAT OIL TRANSFER PUMPS...3 DC PUMPS VISCOMAT DC...3 HAND OPERATED PUMPS FOR OIL DRUMS...4 CLEAN OIL TRANSFER
More informationGE.PK.022/020.SS+0_all
. Generating Set Diesel +0_all Standard Equipment and features Canopy - Soundproofing Engine Soundproof canopy IP 32 removable High coolant temperature and low oil pressure shutdown system Polyester class1
More information3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow
3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow A-VRFC3C-VEI-VS-LS 0M.43.21.80 - Y - Z RE 18309-63 Edition: 03.2018 Replaces: 03.2016 Technical
More informationMarine Fuel Filtration Marine 800 Series
Racor recyclers offer large diesel engine operators both ease of maintenance and continuous engine operation. Continuous operations include filter changeouts and the draining of accumulated water from
More informationAngle seat valve with diaphragm actuator VZXA-...-M
Angle seat valve with diaphragm actuator VZXA-...-M Instructions Operating (Translation of the original instructions) Festo AG & Co. KG Ruiter Straße 82 73734 Esslingen Germany +49 711 347-0 www.festo.com
More informationINSTALLATION MANUAL & OWNER S GUIDE ULTRAVIOLET WATER TREATMENT SYSTEMS Rev. 07/16
INSTALLATION MANUAL & OWNER S GUIDE ULTRAVIOLET WATER TREATMENT SYSTEMS UVB SERIES UV20 SERIES UVBB SERIES RACK SYSTEM UV1 SERIES ADDON SERIES 36103017 Rev. 07/16 TABLE OF CONTENTS INTRODUCTION DESCRIPTIONS
More informationVALVE WITH UV ACTUATOR
CHARACTERISTICS The 3-way stainless steel 783-5+AP (L-port) and 784-6 +AP (T-port) ball valves are dedicated to the mixing, diverting or automatic discharging of industrial unloaded fluids. The valves
More informationinlet/outlet connection flow rates filtration degrees max. working pressure
Pelmar Engineering Ltd. Tel. (888) 754-6329, (416) 288-1736 E-mail: sales@pelmareng.com Web site: www.pelmareng.com 4-6 SK Galaxy High flow, fine filtration automatic disc filtration system inlet/outlet
More informationAQUA2000 ADVANCED WATER TREATMENT SYSTEMS OWNER S MANUAL INCLUDES: Restrictions. Installation. Operation. Maintenance. Changing the Filter
The world leader in products for a healthy and comfortable environment - bringing the Garden of Eden into your home. AQUA2000 OWNER S MANUAL INCLUDES: Restrictions Installation Operation Maintenance Changing
More informationCALEFFI. FLOWCAL Automatic flow balancing valve with polymer cartridge. 121 series 01141/11 NA. Function
FLOWCAL Automatic flow balancing valve with polymer cartridge 121 series REGISTERED BSI EN ISO 9001:2000 Cert. n FM 21654 UNI EN ISO 9001:2000 Cert. n 0003 CALEFFI 01141/11 NA Function The FlowCal automatic
More informationFiltration Ft-Line 34. Ck-Line 38. Cp-Series 42. FilterMax 46. Cintropur filtration 51. Cartridge housings
0. 20. Ft-Line 34. Ck-Line 38. Cp-Series 42. FilterMax 46. Cintropur filtration 5. Cartridge housings 57. Filter cartridges 6. Containers 62. Big cartridge housings 63. Big filter cartridges 9 Ft-Line
More informationElectronic Temperature Sensor ETS 300
Description: The ETS 300 is a compact electronic temperature sensor with digital display. Two different models are available for optimum adaptation to particular applications. The ETS 300 with built-in
More informationDCE 100 Series Dust Filter
Installation, Operation and Maintenance Manual DCE 100 Series Dust Filter Publication 2638B (GB) 0702 1419-8000A Donaldson Torit DCE reserve the right to alter design without notice. Freedom from patent
More informationINSTALLATION MANUAL & OWNER S GUIDE ULTRAVIOLET WATER TREATMENT SYSTEMS Rev. 5/10
INSTALLATION MANUAL & OWNER S GUIDE ULTRAVIOLET WATER TREATMENT SYSTEMS UVB SERIES UV20 SERIES UVBB SERIES RACK SYSTEM UV1 SERIES ADDON SERIES 36103017 Rev. 5/10 TABLE OF CONTENTS INTRODUCTION DESCRIPTIONS
More informationX100 Convertible Filter Housing and Accessories
X1 Convertible Filter Housing and Accessories Maximizing Filtration Efficiency Minimizing Downtime Reducing Filtration Costs FSI has been serving the industry for over 3 years and has earned an ISO 9 certification
More informationPRODUCT OVERVIEW FILTER UNITS
PRODUCT OVERVIEW FILTER UNITS 2018 1 SAND FILTERS IRON REMOVAL FILTERS ACTIVATED CARBON FILTERS Riser tube Riser tube Riser tube Filter gravel 2-3 mm BIRM hydroanthracite (mixed) Activated carbon Lower
More informationFILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS
AMIAD PLASTIC FILTERS, SCREENS & DISCS Max pressure 10 bar, max temperature 60 O 3/4 to 1 1/2 bodies manufactured from poly acetal 2 bodies and above manufactured from poly made and glass fibre 3/4 to
More informationHARMSCO Filtration Products BC6 Series
HARMSCO Filtration Products BC6 Series INSTALLATION AND OPERATION MANUAL Model BC6-1 Model BC6-2 Model BC6-3 BC6, MANUAL Safety Precautions: Before using and installing the parts of this product, please
More informationLINEAR LS CHILLED / CERAMIC / BAIN MARIE
LINEAR LS CHILLED / CERAMIC / BAIN MARIE RF LSRF2 LSRF3 LSRF4 LSRF5 LSRF6 Deck forced refrigeration Canopy LED light Integral condensor Self evaporating Foam insulated double skin base 65mm deep full size
More informationCAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01
CAPACITIVE LEVEL SWITCHES Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01 HYCONTROL CAPACITIVE LEVEL SWITCH RANGE Hycontrol ME capacitive level switches provide simple, accurate and reliable level
More informationAngle seat valve with piston actuator VZXA-...-K
Angle seat valve with piston actuator VZXA-...-K Festo AG & Co. KG Postfach 73726 Esslingen Germany +49 711 347-0 www.festo.com 3 Further information Accessories www.festo.com/catalogue Spare parts www.festo.com/spareparts
More informationController Specification Sheet
Controller Specification Sheet MC9320AXXXBX Proportional Inhibitor Dosing, Conductivity Bleed Control, Redox Control of Oxidising Biocide and Secondary Biocide Dosing PULSAtrol Controllers are microprocessor
More informationPulsation Dampeners NEW! Wanner Engineering Inc
Pulsation Dampeners NEW! Wanner Engineering Inc Pulsation Dampeners Positive Displacement (PD) pumps create pulsation and hydraulic shock due to the reciprocating nature of their stroking action, potentially
More informationHeating oven with natural convection
ED series 23 Drying ovens / Heating ovens Heating oven with natural convection The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C. Thanks to the
More informationFCU Floor Control Unit
Fully assembled with integrated M3V Control Group including mixing valve and circulating pump and in-line high and low temperature Topway T2 FM manifold options with high and low temperature manifold options
More information1 HYDRAULIC POWER UNITS
1 RAIL CLAMPS 1.0 Hydraulic power units rail clamp series HPT04-RCTM HPT08-RCTM HPT04-RCBM MB1V3 HPT08-RCBM 2 2.0 Principle of Operations All HPT - RC system components are modular and easy field replaceable.
More informationSmart controls Reliable operation User friendly design Plug and play operation
Series H2-ID1 RAINSETS Series H2-ID1 Rainsets manage the distribution and water treatment functions of commercial rainwater system installations. The modular H2-ID1 series is designed for indoor installations
More informationUltraviolet Lamps. Worldwide Suppliers of Specialty Lamps. Creating True Value and True Partnership
Ultraviolet Lamps Worldwide Suppliers of Specialty Lamps Creating True Value and True Partnership Company Profile: Founded in 1983, LightSources Inc. has been offering superior products and processes to
More informationJUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering
Data Sheet 22943 Page 1/9 JUMO ecoline Ci Inductive conductivity and temperature sensor for general water engineering Brief description The sensor detects the electrolytic conductivity of a process liquid.
More informationRB15 KNAPSACK SPRAYER
RB15 KNAPSACK SPRAYER Instruction Manual CONTENTS Introduction... 1 Maintenance... 8 Assembly... 2 Troubleshooting... 8 Nozzle Selection... 2 Inspection Check List.. 9 Strap adjustment... 3 To replace
More informationWL250 TOWER DRAWING AND PARTS LIST
WL250 TOWER DRAWING AND PARTS LIST Yellow = Consumables Green = Recommended spare parts WL250 Manual Page 29 Revision: 10 29 2018 No WLCP Part No. Consumables Description Part No Cold Only Hot & Cold Stocked?
More information