solenoids & relays solenoids & relays Continuous Duty 24V insulated 48V insulated 36V insulated A UL-listed
|
|
- Elaine Moody
- 6 years ago
- Views:
Transcription
1 PVC COATED SOLENOIDS WITH STEEL HOUSINGS PLASTIC ODY SOLENOIDS ELECTRONIC SOLENOIDS RELAYS H H H H4 H5 H H INFORMATION ON SOLENOIDS H6 Continuous Duty 85A except where noted. Normally Open Contacts, SPST, One circuit: Off - On Housings: Plated steel (Phenolic where noted). Contacts: Copper 5/6" -4 thread, hexnuts and lockwashers included. 00A solenoids have silver contacts. Coil, ignition and ground terminals: Steel 0- thread, hexnuts and lockwashers included. racket mounting holes 5/6" x 9/" (7.9 x 5.) on /64" centers (56.0mm). 48V insulated See Section H: 4848 heavy duty. 6V insulated Available in Plastic ody (section H): 466, 486 heavy duty V insulated Also available in Plastic ody (section H): PVC coated and UL-rated model: see A PVC coated model: see UL-listed Same as 4080, but UL and CE rated. Continuous Rating: 65A at 6V DC. Intermittent rating: 0A make, 65A break. 0 sec On, 0 min Off. PVC coated model: see 45-0 Cole Hersee Co. 0OldColonyAve, oston, MA Electrical Rating: 00A carry only. Not to break 00A at 4V DC. Silver contacts. CONTINUED H T F
2 H H 4V grounded Normally On V insulated 45 Continuous Duty 5A. 4 V grounded Also available in Plastic ody (section H): 46-G P 4059 P 408 curved bracket PVC coated model: see UL listed P Same as 4059, but UL and CE rated. Continuous Rating: 65A at V DC. Intermittent rating: 750A make, 00A break. 0 sec On, 0 min Off. Circuit G. PVC coated model: see V 4097 insulated 44 00A 405 grounded Electrical Rating: 00A. Silver contacts. 76 Cole Hersee Co. 0OldColonyAve, oston, MA T F
3 H H Two circuits, DPST Normally Off and Normally On. Special application: for forward and reverse systems in electric golf carts, garden tractors, fork lift trucks, winches, etc. Housing: Steel. Continuous Duty, Normally Closed contacts 5A, Normally Open contacts 85A V insulated Latching Solenoid V Continuous Duty,0A (carry only). Insulated. Plated steel housing. Requires only a momentary application of coil power to operate. Very little heat is generated, because the coil is de-energized when the solenoid is On. 400 Momentary Switch + AT LOAD 440 4V insulated Schematic and picture same as V insulated Schematic and picture same as PVC coated model: see V grounded the latching solenoid motor reversing 4 5 Typical DC series wound permanent magnet circuit, using a pair of double-action solenoids. Use pairs of the following solenoids: 440 (V), 440 (4V), or 4400 (6V). SPDT Control Switch Fwd Rev This special solenoid toggles On and Off, and requires no current to maintain the continuity of the power circuit. Use it with a momentary switch (see Momentary Switches). Actuation of the momentary switch causes current to flow in the solenoid coil, locking the contact in place, maintaining the load circuit in an On position. A second actuation of the momentary switch releases the plunger, turning the load circuit Off. Suggested momentary switches: 5507, Special Applications Remote battery isolator In a two-battery system, use the Latching Solenoid to isolate the batteries from each other, and prevent battery drain from the higher into the lower. It has an advantage over electronic attery Isolators (see attery-related Products), in that it will not produce a voltage drop during operation. 440X Series Solenoid 440X Series Solenoid Remote battery disconnect Use it as a remote attery Disconnect Switch. This eliminates the need for heavy gauge wiring between the control panel and the battery. 4 4 To Motor To Motor CONTINUED H Cole Hersee Co. 0OldColonyAve, oston, MA T F
4 H H Intermittent Duty Normally Off, SPST, One circuit: Off - On 750A make, 00A break, 0sec On, 0min Off, except where noted. Contacts: Copper. Terminals: Copper. Small ignition and ground terminals are 0- thread. Large contact terminals are 5/6" -4 thread. Hexnuts and lockwashers are included. racket mounting holes 5/6 x 9/," /64" on centers (7.9 x 5., 56.0mm) and plated steel housing, except where noted. 4V insulated 0A make, 65A break. 0 sec On, 0 min Off , angled bracket 400 phenolic housing, curved bracket 40 phenolic housing 404 V grounded Also available in Plastic ody (section H): 47-GS7, 46-G. V grounded, Resistor Shorting Circuit In this application, is Normally Open. It becomes common with and 4 when the solendoid is energized. Commonly used in engine starting applications. racket mounting holes 9/" x 5/64," 7/64" on centers (7. x 9.9, 5.6mm). RESISTOR SHORTING CIRCUIT M-0 marine PVC coated model: see phenolic housing Marine construction. Clear protective finish, brass hexnuts and lockwashers. racket mounting holes 9/ x /," /64" on centers (7. x.7, 56.0mm). Contact terminal 5/6" -4 thread. 78 Cole Hersee Co. 0OldColonyAve, oston, MA T F
5 H H 48 phenolic, with breather 40 phenolic housing racket mounting holes 9/ x /," /64" on centers (7. x.7, 56.0mm). Contact terminal 5/6" -4 thread. V insulated Also available in Plastic ody (section H): 45-0, 45-, 46-, 47-S6, 47-S racket mounting holes 5/6" x 9/," 9/6" on centers (8. x 7., 65.mm). 40 phenolic housing PVC coated model: 4076 M-00 marine P Same as 4047, but marine construction. Clear protective finish, brass hexnuts and lockwashers. 6V grounded 404 M-00-0 marine, UL listed Same as M-00, but with UL & CE listing. Intermittent rating: 750A make, 00A break.0 sec On, 0 min Off curved bracket V insulated 404 PVC coated model: 4077 Cole Hersee Co. 0OldColonyAve, oston, MA PVC COATED H T F
6 H H5 RELAYS Relay Sockets Accepts Cole Hersee relays and standard ISO relays. Modular sockets dovetail together. Accepts standard quick-connect terminals. Easy mount bracket. Constructed of rugged glass-filled polyamide. Temperature range -40F to 85C High Power Socket 9906 Heavy Duty Socket For use with Cole Hersee Heavy Duty Relays. Form A (SPST) or Form C (SPDT). Use with Tyco (AMP) terminals 48 or Ark-Les 000HA series (consult terminal manufacturers for full specs). For use with Cole Hersee High Power Relays. Form A (SPST) Use with Tyco (AMP) terminals or (consult terminal manufacturers for full specs). H6 INFORMATION ON SOLENOIDS Solenoids are relays which are commonly used to remotely switch a heavier current. y using a solenoid, the amount of heavy wiring needed to power the load is reduced, since the control circuit mounted inside the cab typically utilizes a smaller wire gauge. Solenoids are commonly used to control starter and winch motors, and they have many other uses on vehicles of all kinds. The diagram shows a magnetic coil surrounding a contact plunger. efore energization, the plunger is not electrically connected to the control circuit. When the control circuit is energized, the electromagnetic force induced in the coil attracts the plunger, which moves to close the load circuit. When the control circuit is de-energized, the spring-loaded plunger returns to its normal state and the load circuit is broken. In continuous duty applications, energization of the coil causes heating, therefore the solenoid housing will become warm even in normal operation. CONTROL CIRCUIT STUDS CONTROL CIRCUIT STUDS COIL HOUSING PLUNGER LOAD CIRCUIT STUDS A typical 4-stud solenoid LOAD CIRCUIT STUDS 4-stud solenoid diagram L Solenoid in its normal state Control circut and load circuit open Energized solenoid Control circut and load circuit closed L For more information on solenoids, visit the interactive training section of the Cole Hersee website: > Resource Center > Training. 88 Cole Hersee Co. 0OldColonyAve, oston, MA T F
solenoids & relays solenoids & relays
H STEEL & PHENOLIC BODY SOLENOIDS PVC COATED SOLENOIDS WITH STEEL HOUSINGS PLASTIC BODY SOLENOIDS MODULES RELAYS INFORMATION ON SOLENOIDS H H H H4 H5 H6 H STEEL & PHENOLIC BODY SOLENOIDS Continuous Duty
More informationSWITCHES SECTION. Fuse Holders. Toggle Switches - Screw Terminals. Fuses. Toggle Switches - Blade Terminals. Terminal Block - Junction Box
SWITCHES Toggle - Screw s Toggle - Blade s Toggle (arine) - Blade s Lighted Toggle (arine) Contura III Rocker (arine) Toggle - icro Switch Key Switch Push-Pull Switch Push Button Switch Weatherproof Boots
More informationrotary & headlamp switches
D1 UNIVERSAL ROTARY SWITCHES ROTARY REVERSING SWITCHES ROTARY HEADLAMP & LIGHT SWITCHES RHEOSTAT, AC AND DEFROSTER SWITCHES PUSH-PULL HEADLAMP SWITCHES ELECTRONIC DIMMER SWITCHES UNIVERSAL ROTARY SWITCHES
More informationInfo Sheet. Listing of Cole Hersee retail packs. Littelfuse Commercial Vehicle Products PDF 105
Info Sheet Listing of Cole Hersee retail packs Dated August 2012 Many of our popular products are offered in see-through clamshell packaging, denoted with a BP suffix in price lists. All BP items are packed
More informationSwitches. Common Used Terminology:
Switches Product Description Page# Ball Switches 158 Breakaway Switch 158 Master Disconnect Switch Battery Master Disconnect Switch & Face Plate 159 Plunger Switch Sealed 158 Push/Pull Switches Medium-Duty,
More informationElectro Wizard TM Battery Disconnect Switch
Electro Wizard TM Battery Disconnect Switch FR1051 Technical Specifications Grounded Solenoid (Power Supply Coil Negative) CHARACTERISTICS FR1051 Nominal tension Max 12V Max. continuous current on main
More informationbattery-related products
BATTERY SEECTOR & MASTER DISCONNECT ITCHES MASTER DISCONNECT ITCHES BATTERY ISOATORS ACCESSORIES INFORMATION J1 J2 J3 J4 J5 J J1 BATTERY SEECTOR / MASTER DISCONNECT ITCHES For any vehicle that needs to
More informationSERIES SINGLE AND DOUBLE-POLE ROCKER SWITCHES
TO 1 (4) A 50 V AC PRODUCT FEATURES 100 million times proven switching principle High, fl exible design variety Excellent actuating characteristic Illuminated and non-illuminated variants ON REQUEST Other
More informationSWITCHES & ELECTRICAL ASSEMBLIES
07 96 Battery Disconnect Switches 97 Ignition & Starter Switches 98 Toggle Switches 101 Rocker Switches 102 Push/Pull Switches SWITCHES & ELECTRICAL ASSEMBLIES 103 Solenoids 104 Miscellaneous Switches
More informationpush-pull, rotary & headlamp
G wiper & dimmer switches G3 Electronic Dimmer Switches 74600-02, 4 Amps, Delphi (Packard) Connector Three wires (load, battery, ground) with Delphi (Packard) connector 2984378 on 3" (76.2mm) leads. Duty
More informationTimer Relays - Fixed & Adjustable
Solid State Solid State relays are suitable across all applications where reliability is paramount. Unlike conventional relays, Solid State relays use electronics in place of traditional contacts, allowing
More informationPilot Lights and Warning Devices
Section R R Cole Hersee Pilot Lights and Warning Devices Panel, Map and Utility Lamps Alarms and Buzzers Motor Flashers Consult factory for lights and alarms having specifications other than those shown
More informationcircuit protection & wiring accessories
circuit protection & wiring accessories J J1 circuit breakers Circuit breakers and fuses are a cost-effective solution to protecting wiring, equipment and subsystems. While fuses are a one-time, disposable
More information8500 Series Subminiature Pushbutton Switches
Subminiature Switches Features/Benefits Pre-travel or over-travel models available Ratings up to 3 AMPS Reliable contact design RoHS compliant Typical Applications Detection Telecommunications and networking
More informationItem Number Amps Input Banks Price BI $ BI $95.30 BI $ BI $ BI $203.
SUBHEAD BATTERY ISOLATION Surepower Industries Eliminates multi-battery drain when two or more battery banks are in a charging system Solid-state electronics Each battery discharges and charges according
More informationContacts The moveable contact, which is the one affected by the armature is sometimes referred to as the hinge contact.
Relays & Wiring 101 Basically, a relay is an electrically operated, remotely controlled switch. A simple electromagnetic relay is an adaptation of an electromagnet. It consists of a coil of wire surrounding
More informationBATTERY DISCONNECT SERVICE MANUAL
Battery Disconnect provides a simple and safe means of remotely disconnecting batteries of an RV or boat. With a touch of a remote switch, the batteries will be completely disconnected, preventing unwanted
More informationICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices
ICT TRANSFORMERS Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices TA SERIES INDUSTRIAL CONTROL TRANSFORMER Industrial control transformers
More informationSTARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS
TJ STARTING SYSTEMS 8B - 1 STARTING SYSTEMS CONTENTS page DESCRIPTION AND OPERATION STARTER MOTOR... 2 STARTER RELAY... 3 STARTING SYSTEM... 1 DIAGNOSIS AND TESTING STARTER MOTOR... 8 STARTER MOTOR NOISE
More informationBasics of Control Components
Basics of Control Components Table of Contents Introduction...2 Electrical Symbols...6 Line Diagrams...16 Overload Protection...22 Overload Relays...26 Manual Control...35 Magnetic Contactors and Starters...41
More informationAEC Weekend Seminars Switches, Relays and Contactors. Switches, Relays and Contactors
Switches, Relays and Contactors The switch is one of the oldest technologies in the electrical electronics industry. It s task could not be simpler... Open and Close an Electric Circuit. The science of
More informationspecial purpose switches
MECHANICAL NEUTAL SAFETY SWITCHES NEUTAL SAFETY & BACK-UP SWITCHES OVEDIVE KICKDOWN SWITCHES HEAVY-DUTY WEATHE-ESISTANT SWITCHES FOOT-OPEATED TUN SWITCHES VOLTAGE EDUCES 1 2 3 4 5 6 1 MECHANICAL NEUTAL
More informationProgrammable Logic Controller. Mat Nor Mohamad
Programmable Logic Controller Mat Nor Mohamad Relays Electromagnetic Control Relays The PLC's original purpose was the replacement of electromagnetic relays with a solid-state switching system that could
More informationVALVE BODY. Shift Pressure Control Solenoid Valve. 1. Leaf spring 2. Contact spring 3. Conductor track 4. O-ring 5. O-ring 6.
72 3650 VALVE BODY Shift Pressure Control Solenoid Valve 8 9 7 7 A B C D 10 7 E F 1. Leaf spring 2. Contact spring 3. Conductor track 4. O-ring 5. O-ring 6. Shift plate 7. Leaf spring and socket bolt 8.
More informationSERIES SINGLE AND DOUBLE-POLE ROCKER SWITCHES
TO 0 (4) A 50 V AC PRODUCT FEATURES 100 million times proven switching principle mechanical life endurance up to 1 million switching cycles Wide variety Variants with IP 67 or dust protection insert Two
More informationElectro Wizard Battery Disconnect Switch
TM Electro Wizard Battery Disconnect Switch FR1051 Mounting Diagram Positive disconnection, 12V GROUNDED SOLENOID (power supply coil negative) FR1051 Technical Specifications Positive disconnection, 12V
More informationGeneral Specifications
Series FB & SB Momentary Pushbuttons General Specifications FB Series Electrical apacity (Resistive Load) Power Level: 500mA @ 125V A for silver Logic Level: 0.4VA max. @ 28V A/D max. for gold (Applicable
More informationIndustrial Control Transformers
6 Industrial Control Transformers Section 6 Industrial Control Transformers provide a low and safe control voltage for the operation of electromagnetic devices, such as motor starters, contactors, solenoids
More informationBringing Component Parts Together
Bringing Component Parts Together About Concentric International Concentric International connects retail, wholesale and original equipment manufacturers (OEM) with the value of global sourcing for products
More informationDrop-in Alternative to Tyco/Kilovac* 500+ Amp EV200, plus a lot more (Compare Products) RoHS Compliant, all date codes
Drop-in Alternative to Tyco/Kilovac* 500+ Amp EV200, plus a lot more (Compare Products) RoHS Compliant, all date codes Patent Pending File E320908 All contact ratings and coil versions may not be UL recognized.
More informationStarting Systems & Traction Motor Systems. ATASA 5 th. ATASA 5 TH Study Guide Chapter 18 Pages Starting & Traction Motor Systems 62 Points
ATASA 5 TH Study Guide Chapter 18 Pages 537 570 Starting & Traction Motor Systems 62 Points Please Read The Summary 1. Electric are used to start the engine & in hybrids are used to move the vehicle. Motors
More informationTA Ta VA CTRL-XFRMR
3804 South Street 7964-7263, TX Nacogdoches Phone: 936-69-7941 Fax: 936-60-468 TA2437 Ta-2-437 10VA CTRL-XFRMR Acme Electric Catalog Number TA2437 Manufacturer Acme Electric Description Control Transformer,
More information2006 MINI Cooper S GENINFO Starting - Overview - MINI
MINI STARTING SYSTEM * PLEASE READ THIS FIRST * 2002-07 GENINFO Starting - Overview - MINI For information on starter removal and installation, see the following articles. For Cooper, see STARTER WITH
More informationFunction Relays, Interfaces and Converters
Function Relays, Interfaces and Converters Interface Relays Narrow Design 3TX70 interface relays 3TX701 Interface relay, plug-in Plug-in socket interface, complete with relay Contact Rated control Width
More informationBattery Operation. Battery Construction. Battery State Of Charge. Battery Load Test. Battery Rating Systems 2/14/12
Battery Operation Batteries, Charging and Donald Jones Brookhaven College Batteries convert chemical energy into electrical energy During discharge the battery s plate composition is changed During charging
More informationGeneral Specifications
Series FB & SB Momentary Pushbuttons General Specifications FB Series Electrical apacity (Resistive Load) Power Level: 500mA @ 125V A for silver Logic Level: 0.4VA max. @ 28V A/D max. for gold (Applicable
More informationMODEL EVA PARTS MANUAL Rev.1.03
MODEL EVA PARTS MANUAL Rev.1.03 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 www.cmadishmachines.com TABLE OF CONTENTS MODEL EVA 1. PARTS MANUAL...3
More informationM O D E L S EST- FL PARTS MANUAL Rev 1.00A
M O D E L S EST- FL PARTS MANUAL Rev 1.00A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com TABLE
More informationSERIES SINGLE AND DOUBLE-POLE ROCKER SWITCHES
TO 1 (4) A 50 V AC ROCKER SWITCHES PRODUCT FEATURES 100 million times proven switching principle High, fl exible design variety Excellent actuating characteristic Illuminated and non-illuminated variants
More informationDistributed by: www.jameco.com 1-800-831-4242 The content and copyrights of the attached material are the property of its owner. Features/Benefits Multi-pole and multi-position Positive detent Shorting
More informationtable of contents Switches J 1 SECTION SECTION J Quick Guide to Switches... J2-J3
table of contents Switches Quick Guide to Switches....................................... J2-J3 Push Switches.............................................. J4-J7 Single Pole ON-OFF.......................................
More informationcircuit protection & wiring accessories
circuit protection & wiring accessories P1 P BLOCKS & BUSBARS TERMINAL BLOCKS P2 P3 CONNECTORS, TERMINALS & FUSES P4 CLAMPS, CLEATS, CLIPS & TIES P5 P1 circuit protection & wiring accessories ACCESSORIES
More informationcolehersee.com heavy duty catalog Manufacturers of DC electrical and electronic switches and connectors for the vehicle industry
D-400 Cole Hersee Co. DC Electrical Switches D-400 Cole Hersee heavy duty catalog colehersee.com Manufacturers of DC electrical and electronic switches and connectors for the vehicle industry Manufacturers
More informationSwitches. SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY 115VAC, 28VDC)
SWITCH SELECTION GUIDE Toggle Switches SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY (Resistive @ 115VAC, 28VDC) T1 2 or 3 Position, Momentary, 8A MIL-PRF-83731 15/32" or 1/4" dia.
More informationMB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR
MB-3688 120A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR User Manual Warning and Precautions MB-3688 is built with corrosion resistant material and the main electronic assembly is well sealed inside
More informationOCTOPUS SELECTION & INSTALLATION GUIDE Rev. C CRA SERIES CONTINUOUS RUNNING PUMPSET
A. GENERAL DESCRIPTION: OCTOPUS SELECTION & INSTALLATION GUIDE Rev. C CRA SERIES CONTINUOUS RUNNING PUMPSET Octopus CRA continuous running pumps are very reliable quiet and efficient devices which will
More informationABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet
ABB Instruction Leaflet 41-137.2E Effective: February 1994 Supersedes I.L. 41-137.2D, Dated February 1973 ( )Denotes Change Since Previous Issue. Type KRV Directional Before putting relays into service,
More informationThe Electromagnet. Electromagnetism
The Electromagnet When you have completed this exercise, you will be able to explain the operation of an electromagnet by using a coil of wire. You will verify your results with a compass and an iron nail.
More informationSpare Parts List. EW-3500-C and D EW-4200-C and D Marine Diesel Generators
ENTEC WEST, INC. Spare Parts List EW-3500-C and D EW-4200-C and D Marine Diesel Generators Every generator produced by Entec West, Inc. has been recorded in a master computer file by serial number. This
More informationELECTRICITY AND HWH COPPER CONDUCTOR
1. PREFACE +BATTERY TERMINAL +BATTERY TERMINAL + + + + + + + + + + + + ELECTRICITY AND HWH In the first section of this school, we did an in-depth study of general hydraulics. In section four, we applied
More informationD. S. HULL COMPANY, INC
M484-BP M493-BP M584-BP 5582-BP 55020-BP 55088 Toggle Switches Cole Hersee Standard Toggle Switches Non-corrosive construction throughout. Durable, moisture repellent plastic housing. Silver contacts.
More information5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps
5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps The 5 series is a 2 coil mechanical latch electrical reset power relay. It is panel mounted with screw terminals, and has 600 volt spacing. The 5 series
More informationrefrigeration SHAKE #15-77CMT ICE CREAM MACHINE ELECTRO FREEZE 21 SHAKE DISPENSE HEAD ASSEMBLY SHAKE BEATER SEAL ASSEMBLY 9
SHAKE DISPENSE HEAD refrigeration SHAKE #-CMT 0 SHAKE BEATER SEAL EF Head Dispense, Shake side EF Bushing, Beater Bearing EF O-Ring Head EF O-Ring Plunger, Lower, pkg of EF0 O-Ring Plunger, Upper, pkg
More informationMODEL EVA PARTS MANUAL Rev.1.05
MODEL EVA PARTS MANUAL Rev.1.05 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 www.cmadishmachines.com TABLE OF CONTENTS MODEL EVA 1. PARTS MANUAL...3
More informationMagnetic Alarm Switches
S99 Can be installed/wired to be Normally Closed & Normally Open Commonly Seen on Door and Window Alarms.315 (8.0) 2.134 (54.2).203 (5.15) 2.134 (54.2).535 (13.6).203 (5.15).203 (5.15).551 (14.0).067 (1.7).787
More informationStreet Trucks Groundskeeping Cranes of all kinds Agriculture, Forestry & Mining
Street Trucks Postal Vehicles Utility Company Trucks Bucket Trucks Delivery Trucks Street Sweepers Garbage Trucks Dumpster Trucks Snowplows Groundskeeping Golf Carts Service Carts Mowers Ditch Diggers
More informationElectropneumatic Timing Relays Series 7000 Industrial
DESIGN FEATURES Available in On-Delay, True Off-Delay, and On/Off-Delay. Timing from 0.1 seconds to 60 minutes, fully calibrated in linear increments. Oversize time-calibrated adjustment knobs, serrated
More informationKEY PART # DESCRIPTION KEY PART # DESCRIPTION
SINGLE HEAD BEATER SHAFT EF0 Head Dispense w/actuator EF Nozzle, Serrated EF Knob, Hand EF00 Handle Assembly Dispense w/knob EF Knob Ball, /"-, THD Black EF Pin Handle EF Plug for O-Ring, pkg of EF Plug,
More informationControl Relays Overview
Control Relays Overview DESIGN FEATURES Among the advances Agastat Control Relays offer over existing designs is a unique contact operating mechanism. An articulated arm assembly amplifies the movement
More informationCruise Control Wiring
Cruise Control Wiring By Matt Sandt, Revised 3-28-16 The approach described in this writing applies to solar car motor controls which use a potentiometer connected to a gas pedal. The potentiometer is
More informationDistinctive Characteristics
Distinctive Characteristics Various cap styles and colors to meet differing application needs. Bright, full face illumination to distinctively indicate status. Rear panel threaded mounting or snap-in mounter
More informationEPIC Hermetic Sealed DC and AC Contactor Amp Power Switching RoHS Compliant, all date codes
EPIC Hermetic Sealed DC and AC Contactor - 150+ Power Switching RoHS Compliant, all date codes File E320908 All contact ratings and coil versions may not be UL recognized. Contact GIGAVAC for a copy of
More informationIMI vibration switch USER MANUAL INSTALLATION - OPERATION - MAINTENANCE
USER MANUAL IMI vibration switch INSTALLATION - OPERATION - MAINTENANCE Z0929039_A ISSUED 03/2017 READ AND UNDERSTAND THIS MANUAL PRIOR TO OPERATING OR SERVICING THIS PRODUCT. contents Overview General
More informationMiniature microswitches - Positive break
1 Miniature microswitches - Positive break 81607 Coil spring snap-action mechanism with wiping contacts Positive opening action according to IEC 6097-5-1 Annex K atings from 10 ma Vc to 6 A 250 Va Very
More informationDeep Well Pump Control Valve
MODEL 61-02 661-02 Deep Well Pump Control Valve Prevent Surges in Pipelines Simple Hydraulic Operation Adjustable Opening & Closing Speeds Solenoid Control Can Be Operated Manually Proven Reliable Design
More informationThe world s leading independent supplier of energy control solutions for engines, turbines, and power equipment.
Over the past 70 years you ve known us as Synchro-Start Products, but in May 2003 we became Woodward. With the resulting expansion in product lines, increased ability to provide customized system solutions,
More informationSERIES SINGLE AND DOUBLE-POLE PUSHBUTTON SWITCHES
PRODUCT FEATURES Illuminated and non-illuminated pushbutton switch Proven jump contact switching system (double interrupting) Opening and closing speed independent of the actuating speed Product-dependent
More informationService Manual for Battery Control Center
Service Manual for Battery Control Center P/N 82 E0071 00 (Ref. 81 1317) June, 1999 Battery Control Box Operation Charging Circuit This function charges the coach battery from the engine alternator while
More informationReversing Hand Throttle and Horn Relay Board RBT / HRB
Instruction Manual Reversing Hand Throttle and Horn Relay Board RBT / HRB Contents Section Page Section Page 1. Introduction... 2 2. Do's and Don ts... 2 3. Horn Relay Board... 3 3.1 HRB Versions... 3
More informationNRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute
RA Series RA Series Key features of the RA series include: Available in 5 different styles Excellent overload and short circuit protection Small size and high-efficiency Life expectancy of over 0,000 operations
More informationLiftgate Terminology
SL-20 Series SL-20 Series Click the appropriate link below for the major component of the liftgate for which you are trying to find the correct part. If you are unsure of the name of the part in Waltco
More informationSolenoid valve. Solenoid Coil
Solenoid valve Solenoid valve Solenoid Coil Plunger Valve body A simple solenoid valve consists ofi: Valve body with a plunger the plunger is made of metal Coil an electrical coil if the coil is given
More informationElectromagnetic Induction
Electromagnetic Induction Question Paper Level ubject Exam oard Unit Topic ooklet O Level Physics ambridge International Examinations Electricity and Magnetism Electromagnetic Induction Question Paper
More informationcircuit protection & wiring accessories
circuit protection & wiring accessories CIRCUIT BREAKERS P1 P BLOCKS & BUSBARS TERMINAL BLOCKS P2 P3 CONNECTORS, TERMINALS & FUSES P4 CLAMPS, CLEATS, CLIPS & TIES P5 P1 circuit protection & wiring accessories
More informationelectronic devices electronic devices MINIBUS DIGITAL DATABUS SYSTEM MiniBus Digital Databus System System Features System components
TIMER/DIMMER MODULES DAYTIME RUNNING MODULE TAILLITE CONVERTER MODULE K1 K2 K3 K4 K K1 MiniBus Digital Databus System Controls and monitors electrical motors and lighting using very low currents. Modular
More informationGrout Pump Automatic & Manual Troubleshooting Gas Wiring Diagram
Grout Pump Automatic & Manual Troubleshooting 40-500 Gas Wiring Diagram Turn engine off and relieve hydraulic pressure and grout pressure before troubleshooting. Note: Typically there is a wiring diagram
More informationAutomotive Parts. Charging & Starting Systems
Automotive Parts Charging & Starting Systems Charging Systems Output voltage kept to about 2 volts higher than battery voltage Controlled by varying current into rotor field winding (voltage regulator
More information8 Channel 5V Optical Isolated Relay Module
Handson Technology Data Specification 8 Channel 5V Optical Isolated Relay Module This is a LOW Level 5V 8-channel relay interface board, and each channel needs a 15-20mA driver current. It can be used
More informationTattletale Annunciators and Magnetic Switches
Tattletale Annunciators and Magnetic Switches Tattletale annunciators and magnetic switches are the nerve centers that translate Swichgage contact operations into decisions and operate the alarm or shutdown
More informationBooster Pump Control Valve
MODEL 60-7 660-7 ooster Pump Control Valve Simple Hydraulic Operation Low Head Loss Horizontal or Vertical Mounting uilt-in Check Valve Proven Reliable Design The Cla-Val Model 60-7/660-7 ooster Pump Control
More informationPush buttons are of two types i) Momentary push button ii) Maintained contact or detent push button
ELECTRO-PNEUMATIC Push button switches A push button is a switch used to close or open an electric control circuit. They are primarily used for starting and stopping of operation of machinery. This causes
More informationMODEL CMA-44 PARTS MANUAL Rev 2.13
MODEL CMA-44 PARTS MANUAL Rev 2.13 CMA DISHMACHINES 12700 KNOTT AVENUE GARDEN GROVE, CALIFORNIA 92841 800-854-6417 FAX 714-895-2141 www.cmadishmachines.com Table of Contents CMA-44 1. PARTS MANUAL... 4
More informationCoil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q
14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose
More informationSwitch Machines Installation & Wiring
Switch Machines Installation & Wiring Conventional Twin Coil Switch Machines Electrically: In use since developed by Walthers in early 1930 s Long time standard for remote operation Currently: Rix, Atlas,
More informationJD TRIPLE EGRESS TRIPLE EGRESS SECTION
JD 52-5525 TRIPLE EGRESS TRIPLE EGRESS SECTION 5525 EGRESS 5-1 ASSEMBLY - TRIPLE EGRESS, CAB TRIPLE EGRESS MOUNTING Park the tractor on a flat, hard, level surface. Lower both side decks down onto the
More informationBERMAD Irrigation. Solenoid Valves S - Series. Water Control Solutions
Solenoid Valves Water Control Solutions Company Profile Experience and proven results have made BERMAD synonymous with water and other fluid control and management. Cutting-edge technology is one of the
More informationSERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY (Resistive)
SWITCH SELECTION GUIDE Trim Switches SERIES FEATURE ACTUATION MAX RATING SEAL RATING MOUNTING CIRCUITRY (Resistive) MT T1 Quiet Operation, Momentary 10mA @ 5VDC IP64, IP68S 11/16 dia. Threaded SPST (x2)
More information» Principals of Spider -Valve VA series
» Principals of Spider -Valve VA series 2-way-Spider -Valve, direct actuated, NC In the rest position the leaf spring pushes the disk armature with sealing element against the valve seat. The medium supports
More informationHYDRAULIC LINEAR ACTUATOR LA17 TABLE OF CONTENTS. 1. GENERAL INFORMATION... p TECHNICAL SPECIFICATIONS and APPLICATION... p.
HYDRAULIC LINEAR ACTUATOR LA17 TABLE OF CONTENTS 1. GENERAL INFORMATION... p. 01 2. TECHNICAL SPECIFICATIONS and APPLICATION... p. 02 3. DESCRIPTION... p. 03 3.1 General 3.2 Pump Unit (HRP17) 3.3 Reservoir/Bypass
More informationHYDRAULIC LINEAR ACTUATOR LA17 TABLE OF CONTENTS. 1. GENERAL INFORMATION... p TECHNICAL SPECIFICATIONS and APPLICATION... p.
HYDRAULIC LINEAR ACTUATOR LA17 TABLE OF CONTENTS 1. GENERAL INFORMATION... p. 01 2. TECHNICAL SPECIFICATIONS and APPLICATION... p. 02 3. DESCRIPTION... p. 03 3.1 General 3.2 Pump Unit (HRP17) 3.3 Reservoir/Bypass
More informationPower systems Protection course
Al-Balqa Applied University Power systems Protection course Department of Electrical Energy Engineering Dr.Audih 1 Part 3 Protective Devices Fuses & Circuit Breakers 2 Introduction: Fuse Is advice used
More informationCoil Data Nominal Current MA Nominal VA Sealed. Coil Data Nominal Current MA Nominal VA Sealed. Single Pole Double Throw (SPDT)
14/03/08 A136 Relay - General Purpose 90-293Q Enclosed fan relays used for switching single or two speed fan motors, solenoids, relays, resistive loads, heating and cooling applications and general purpose
More informationFULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION
505 z 509 FULL VOLTAGE STARTERS z SIZE 8 SERIES B CONSTRUCTION The movable contacts are carried in stainless steel cages which in turn are mounted in cavities in the molded portion of the cross bar. This
More informationPRODUCT CATALOG 2004 SOLENOIDS ACTUATORS ENGINE CONTROLS ELECTROMAGNETIC CONTROLS AND SYSTEMS
PRODUCT CATALOG 2004 SOLENOIDS ACTUATORS ENGINE CONTROLS ELECTROMAGNETIC CONTROLS AND SYSTEMS Over the past 70 years you ve known us as Synchro-Start Products, but in May 2003 we became Woodward. With
More informationElectricity Merit Badge
Electricity Merit Badge Class 2 - Magnetism 1 Classes Class 1 Basic Electricity (shared with the Electronics Merit Badge) Class 2 Magnetism Magnets & Compasses Electromagnets & Coils Solenoids & Electric
More informationDissolved Oxygen Measurement System with Air Blast Cleaner
Product Data Sheet PDS 71-DO-03/04/rev.D August 2004 MODEL DO -03/-04 Dissolved Oxygen Measurement System with Air Blast Cleaner COMPLETE SYSTEM INCLUDES sensor, analyzer, sensor washer head, mounting
More informationThe Complete System Solution! Highest Grade Electronic Components RoHS Compliant.
Advantages of the 72 Alternating Relay The Complete System Solution! Highest Grade Electronic Components RoHS Compliant. The Model 72 series Alternating Relay is designed for duplex pumping systems where
More informationS (8.0) (5.15).551 (14.0) .275 (7.0) S100
Normally Closed & Normally Open S99.315 (8.0) 2.134 (54.2).203 (5.15) 2.134 (54.2).203 (5.15).535 (13.6).203 (5.15).551 (14.0).067 (1.7).787 (20.0).157 (4.0) Type Circuitry Action Actuator 54 627 SPDT
More informationAP MOTRONIX PRIVATE LIMITED
1 of 19 AP MOTRONIX PRIVATE LIMITED 3-18-3, Pragathi Nagar, Ramanthapur, Hyderabad 500013. INDIA. Off.: 040-27038560/1929 E-mails: sales@apmotronix.com; Website: www.apmotronix.com purchases@apmotronix.com
More informationNote 8. Electric Actuators
Note 8 Electric Actuators Department of Mechanical Engineering, University Of Saskatchewan, 57 Campus Drive, Saskatoon, SK S7N 5A9, Canada 1 1. Introduction In a typical closed-loop, or feedback, control
More information