WELCOME TO MAGNATROL

Size: px
Start display at page:

Download "WELCOME TO MAGNATROL"

Transcription

1 Catalog 6

2 BULLETIN 6-INDEX WELCOME TO MAGNATROL Process Control Solenoid Valves For Water Oil Air Gas Steam Cryogenics Vacuum Solvents Brine Oxygen Corrosive Fluids Magnatrol Valve Corp. Established 1936 Experienced Dedicated Sales Staff Application / Engineering Assistance Excellent Product Support Quick Delivery Our continued success has come from manufacturing a top quality product, product support, commitment to service and on-time delivery assuring complete customer satisfaction. Our Products Every valve is manufactured and tested in-house following Quality Assurance Standards where production operations are under the control of our dedicated, experienced staff and workforce. TABLE OF CONTENTS Category Pages(s) Coils Construction Features Bronze Valves N & NR & A & AR & 9 M & MR & S & SR & 13 L & LR & 15 G & GR & 1 D Strainers Stainless Steel Valves J & JR & 21 K & KR & W & WR & Optional Features & 2 Special Valves Universal Mount P Sandy Well Water Gritty Coolant & 31 Ordering Information & Terms & Conditions/Contact Info * Custom Engineered Valves, Special Alloys, Temperatures, Pressures and Applications as well as Modifications to Standard Magnatrol Valves are available through Magnatrol s Clark-Cooper Division. (See bottom of page 3) High Quality Bronze and Stainless Steel Solenoid Valves* Pressures up to 0 * Temperatures up to 0 F * Cryogenic and Oxygen Service Applications Normally Closed (Energize to Open) Normally Open (Energize to Close) Continuous Duty Coils for all & Voltages NO Differential Pressure Required to Open Full Port-Internal Pilot Operated or Direct Acting 2-Way Straight Thru Design Packless Construction 2 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

3 BULLETIN 6-VALVE SELECTION CHART VALVE SELECTION CHART Ordering Information - See Pages 32 & For Optional Features - See Pages 26 & 2 VALVE SELECTION CHART (For Fluids/Gases Not Listed And For Special Applications, Consult Factory) Max. Temperature Up To 212 F Up To 0 F Construction Bronze Stainless Steel Valve Type D G/GR N/NR A/AR M/MR S/SR L/LR K/KR W/WR Page 16 & 1 6 & & 9 & 12 & & & & Max. Pressure / /4-3 3/ -3/ Internal Port Full Full Reduced Full Reduced Full Full Full Full Air Brine Gas Oil Solvents Water Vacuum Steam Cryogenic Oxygen, Liquid Oxygen, Gaseous Corrosive Use the chart above to determine suitable types of Magnatrol valves for a given application. Example: A normally closed valve for use on 0 psi steam, there are three types suitable and the final selection can only be made after referring to Bulletins 6-M, 6-S and 6-W on pages, 12 and 22 respectively. Maximum Differential Pressure: When specifying a valve, the Maximum Differential Pressure must be equal to or greater than the application. Care should be taken not to over specify the valve by choosing a valve with a Maximum Differential Pressure that is excessively beyond the application. If you are unsure please consult the factory. 2-Way and 3-Way 1/4 Thru 6 Pressures to,000 s up to 5 F Dirty / Viscous & Corrosive Fluids Bronze, 316SS, Monel, Alloy 20 & Hastelloy 3-Valve Manifold for CNG Refueling End connections: NPT, Flange, Union, Socket Weld, Butt Weld, Nipples etc. Options: Remote Trip with Manual or Automatic Reset and many others High Pressure Cartridge Valve,000 3-Way Trip Valve with 2 Position Indicating Switches and Manual Reset Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 3

4 BULLETIN 6-COIL SOLENOID COILS CONTINUOUS DUTY COILS ELECTRICAL CHARTERISTICS Coils are stocked for the following voltages: Voltage , Hertz * * 5V for locomotive applications * Furnished with surge protecting capacitor Reference should be made to the Bulletins to determine the availability of a required valve for a specific power supply. Consult the factory for information regarding voltage and frequencies not listed. ENCAPSULATED COIL Valves for A.C. service can be converted for use on other A.C. voltages simply by changing the coil. Similarly D.C. valves can be converted for other D.C. voltages. Consult factory regarding conversion from A.C. to D.C. or D.C. to A.C. CURRENT CONSUMPTION: Current values shown in the bulletins are for 120 volts, hertz. For other voltages the current is inversely proportional: For instance, if a given valve draws 0.5 amperes on 120 volts it would draw 0. amperes on 2 volts, or 0.1 amperes on volts. Where power consumption is shown in D.C. watts, the values given should be divided by line voltage to obtain the current in amperes. Power consumption for all valves is shown in the individual bulletins. CONSTRUCTION: Continuous Duty Construction: Coils can be energized continuously without overheating or failure. Wire Leads: long gauge wire standard (longer continuous leads available) Encapsulated: Coils are encapsulated for temperature of intended service, providing excellent resistance to shock, moisture, oil and chemicals COIL CLASS: GENERAL SERVICE - CLASS B HIGH TEMPERATURE - CLASS H Maximum Fluid Maximum Ambient Maximum Fluid Maximum Ambient Temperature Temperature Temperature Temperature 212 F ( C) 04 F ( C) 00 F (206 C) 12 F (0 C) INSTALLATION: The coil is a two wire device which may be controlled by either a single or double pole switch. The switch should always be installed in the hot leg of 120 volt circuits. Where both legs are hot, such as 2 or volt circuits, a double pole switch is preferable, however, if a single pole switch is used, then the wiring should have top quality insulation since even minute leakage currents may give rise to sticking problems. On motor hookup with step control starter, full voltage should be supplied to coil immediately. Note: Coil can be readily changed while valve is still under pressure. 4 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

5 BULLETIN 6-CONSTRUCTION VALVE CONSTRUCTION FEATURES Valve Construction Features: 2-way straight thru globe design Bronze or Stainless Steel body w/ female NPT threads standard Stainless Steel available with 1# and # flanged ends Full port-internal pilot operated or direct acting Packless construction Continous duty coils for all voltages No differential pressure required to open Easy In-Line Service Inspect, clean or service all internal parts of full port-internal pilot operated or direct acting while the valve body remains in the pipeline shortening costly down time and increasing productivity. HOUSING Construction: Malleable or Cast Iron Designed for rugged industrial use Self contained terminal box with NPS conduit connection COIL Available Class B or H insulation Designed for continuous duty service Available in most or voltages Coil Enclosure Available: NEMA 12, 4, 4X and Explosion Proof Conduit Boss Coil BONNET PISTON ASSEMBLY A sturdily constucted stem assembly consisting of a plunger and stainless steel pilot flexibly connected to the piston Discs are available in various materials dictated by operating conditions A flanged metallic tube encloses the plunger and hermetically seals the top of the valve VALVE BODY Constructed of high pressure cast bronze or stainless steel in a globe pattern with screwed ends* Bonnet Piston Valve Disc Disc Nut Bonnet Ring Plunger Valve Spring Pilot Valve Valve Body Normally Closed Valve shown is typical of Type A, thru 1-1/4 Available in a full range of sizes * Stainless Steel valves available with flanged ends. Flanged Bronze valves available through Magnatrol s Clark-Cooper Division (See bottom of MAGNATROL SOLENOID OPERATED VALVES are used to control the flow of liquids or gases, generally in conjunction with automatic control apparatus such as thermostat, float switch, time switch, or flow meter. Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 5

6 BULLETIN 6-N BRONZE SOLENOID VALVES 212 F FOR OPTIONS & CESSORIES TYPE N - NORMALLY CLOSED TO 3/4 PIPE SIZE DIRECT TING - ORIFICE SIZES 3/32 TO Valve opens when energized and closes when de-energized. In this direct acting valve, when the coil is energized, the stem is lifted from its conical seat by the plunger. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends Coil Enclosure - Malleable Iron, NPS conduit conn. *Valve Stem Stainless Steel *Spring Stainless Steel *Body Seal - Buna N *Orifice Seal - Metal to Metal * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, leads - (Class H available) To control the flow of Water, Oil, Air, Gas, Solvents, Brine, Vacuum and any other fluids not reactive with construction materials and free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 3/ Max. Valve Port Hold Inrush DISCONTINUED -- USE VALVE WITH BUSHING A Dimensions In B C D 3/4 3/ N22 1/4 N42 5 3/16 N /4 5-3/ 2-3/4 2-3/4 0 5/32 N2 1 1/ N62 2 3/32 N2 3/ N22 5 5/16 N32 0 1/4 N / 6-3/ 2-3/4 1 3/16 N52 1/ N62 15 N13 5/16 N / 2-3/4 2-/ 30 N / 6-2-/ 5 5/16 N Voltage ( or ) Optional Soft Seat Orifice Seal (for applications requiring tight seating) Viton - Suitable for Fuel Oils, Gaseous Oxygen and other compatible fluids 6 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

7 BULLETIN 6-NR BRONZE SOLENOID VALVES TYPE NR - NORMALLY OPEN TO 3/4 PIPE SIZE DIRECT TING - ORIFICE SIZES 3/32 TO Valve closes when energized and opens when de-energized. In this direct acting valve, when the coil is energized, the stem is pressed into its conical seat by the plunger. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends Coil Enclosure - Malleable Iron, NPS conduit conn. *Poppet Stainless Steel *Stem Stainless Steel *Spring - Inconel *Body Seal - Buna N *Orifice Seal - Metal to Metal * Shading Coil - Copper *Stem Pin Stainless Steel Coil - Encapsulated Class B, leads - (Class H available) To control the flow of Water, Oil, Air, Gas, Solvents, Brine, Vacuum and any other fluids not reactive with construction materials and free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 212 F FOR OPTIONS & CESSORIES 3/ Max. Valve Port Hold Inrush DISCONTINUED -- USE VALVE WITH BUSHING A Dimensions In B C D Voltage ( or ) 3/4 3/ NR22 1/4 NR42 0 3/16 NR /32 NR / 2-3/4 2-3/4 1 1/ NR62 3/32 NR2 3/ NR22 0 5/16 NR /4 NR / -1/ 2-3/4 1 3/16 NR / NR62 13 NR /16 NR /4 6-3/ 2-3/4 2-/ 2 NR13 0 5/16 NR / -1/4 2-/ Optional Soft Seat Orifice Seal (for applications requiring tight seating) Viton - Suitable for Fuel Oils, Gaseous Oxygen and other compatible fluids Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

8 BULLETIN 6-A BRONZE SOLENOID VALVES 212 F Except valves listed for 0 TYPE A FULL PORT - NORMALLY CLOSED TO 3 PIPE SIZE Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve Stainless Steel *Spring Stainless Steel *Body Seal - Buna N or Non Asbestos Gasket * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, leads - (Class H available) Vacuum materials and free of sediment. Valve operates from zero to maximum horizontal pipe with solenoid enclosure vertical and on top. 3/ / Max Dimension In Hold Inrush A B C D 1 A42 A32 A / 2-3/4 3-1/4 0 EA / 4-1/ 3-1/4 1 A A A / 6 2-3/4 A53 A / 0 E1A / 4-1/ 1 A24 A A / 6-5/ 2-3/4 4-1/ A54 A / - 4-1/ 4-1/ 0 E1A / - 4-1/ 4-1/ 90 A A A / 6-3/4 2-3/4 4- A A / -3/4 4-0 A / -3/ A46 1A46 4. A / 4 4-/ 41A36 41A A / 4-4-/ 0 36A2 36A A /4 5-3/ 6 42A3 42A /4 5-3/ A A2 1 43A4 43A / -1/ 5-/ -1/4 143A A29 44A49 44A /4-6-5/ -3/ 144A D(Flanged) 1# 4-3/ /4 9- FOR OPTIONS & CESSORIES Voltage ( or ) Not available for operation Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

9 BULLETIN 6-AR BRONZE SOLENOID VALVES TYPE AR FULL PORT - NORMALLY OPEN TO 3 PIPE SIZE Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve Stainless Steel *Spring Stainless Steel *Body Seal - Buna N or Non Asbestos Gasket *Orifice Seal - Buna N (Viton or Glass Filled Teflon available) * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, leads - (Class H available) To control the flow of Water, Oil, Air, Gas, Solvents, Brine, Vacuum and any other fluids not reactive with construction materials and free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. FOR OPTIONS & CESSORIES Voltage ( or ) Not available for operation 3/ / Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey F Except valves listed for 0 Max Dimension In Hold Inrush A B C D 1 AR42 AR32 AR / 2-3/4 3-1/4 0 EAR / -1/4 4-1/ 3-1/4 1 AR AR /4-1/ 2-3/4 AR AR /4-1/ 0 E1AR / 4-1/ 1 AR24 AR /4 2-3/4 4-1/ AR34 AR / 4-1/ 0 E1AR /4 -/ 4-1/ 4-1/ 90 AR AR /4-1/ 2-3/4 4- AR AR /4 9-1/ 4-0 AR / AR26 AR / / 41AR AR56-5/ 9-3/4 4-4-/ 0 141AR AR2 36AR / -1/ 5-3/ 6 42AR3 42AR AR / -3/ 5-3/4 6 43AR2 1 43AR AR / -1/4 44AR29 143AR AR AR / -1/ 6-5/ -3/ 144AR D(Flanged) 1# 4-3/ /4 9-9

10 BULLETIN 6-M BRONZE SOLENOID VALVES 0 F 1 FOR OPTIONS & CESSORIES TYPE M - NORMALLY CLOSED 3/ TO 3/4 PIPE SIZE DIRECT TING - ORIFICE SIZES 1/ TO Valve opens when energized and closes when de-energized. In this direct acting valve, when the coil is energized, the stem is lifted from its conical seat by the plunger. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends Coil Enclosure - Malleable Iron, NPS conduit conn. *Valve Stem Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Metal to Metal * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class H, leads To control the flow of Steam, Hot Liquids, Hot Gases, Cryogenics** and any other fluids not reactive with construction materials and free of sediment. Cryogenic fluids include Liquid Oxygen (-29 F), Liquid Argon (-303 F) and Liquid Nitrogen (-320 F). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. INLET 3/ 3/4 Max. Valve Port **Cleaning: Cryogenic valves are degreased and cleaned to keep them free of moisture. Oxygen valves are also black light tested. Hold Inrush 3/ M21 1/4 M41 5 3/16 M /4 5-2-/ 2-5/ 0 5/32 M1 1 1/ M61 3/ M /16 1/4 M31 M / 6-3/ 2-5/ 1 3/16 M51 3/ M22 1/4 M42 5 3/16 M /4 5-2-/ 2-3/4 0 5/32 M2 1 1/ M62 3/ M /16 1/4 M32 M / 6-3/ 2-3/4 1 3/16 M /16 M13 M / 2-/ 2-/ /16 M13 M / 6-2-/ A Dimensions In B C D Optional Soft Seat Orifice Seal (for applications requiring tight seating) Viton - Suitable for Fuel Oils, Gaseous Oxygen and other compatible fluids Voltage ( or ) Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

11 BULLETIN 6-MR BRONZE SOLENOID VALVES TYPE MR - NORMALLY OPEN 3/ TO 3/4 PIPE SIZE DIRECT TING - ORIFICE SIZES 1/ TO Valve closes when energized and opens when de-energized. In this direct acting valve, when the coil is energized, the stem is pressed into its conical seat by the plunger. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends Coil Enclosure - Malleable Iron, NPS conduit conn. * Poppet Stainless Steel *Stem Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Metal to Metal * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class H, leads Voltage ( or ) (See pages 26& 2) 3/ 3/4 Max. To control the flow of Steam, Hot Liquids, Hot Gases, Cryogenics** and any other fluids not reactive with construction materials and free of sediment. Cryogenic fluids include Liquid Oxygen (-29 F), Liquid Argon (-303 F) and Liquid Nitrogen (-320 F). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 0 F 1 FOR OPTIONS & CESSORIES **Cleaning: Cryogenic valves are degreased and cleaned to keep them free of moisture. Oxygen valves are also black light tested. Valve Port Hold Inrush 3/ MR21 1/4 MR41 0 3/16 MR /4 2-/ 2-5/ 90 5/32 MR1 1 1/ MR61 3/ MR /16 1/4 MR31 MR / -1/ 2-5/ 1 3/16 MR51 3/ MR22 1/4 MR42 0 3/16 MR /4 2-/ 2-3/4 90 5/32 MR2 1 1/ MR62 3/ MR /16 1/4 MR32 MR / -1/ 2-3/4 1 3/16 MR /16 MR13 MR /4 6-3/ 2-/ 2-/ 2 0 5/16 MR13 MR / -1/4 2-/ Optional Soft Seat Orifice Seal (for applications requiring tight seating) Viton - Suitable for Fuel Oils, Gaseous Oxygen and other compatible fluids UL Listed Valves - Consult Factory Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 A Dimensions In B C D

12 BULLETIN 6-S BRONZE SOLENOID VALVES 0 F TYPE S FULL PORT - NORMALLY CLOSED TO 3 PIPE SIZE Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Glass Filled Teflon * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class H, leads FOR OPTIONS & CESSORIES Max / / S22 4S42 129S42 14S 4S43 129S43 16S14 6S24 6S44 131S44 1S15 S 132S 1S S16 S26 1S46 141S46 36S1 36S2 42S4 142S4 43S 43S2 43S4 143S4 44S19 44S29 44S49 144S Hold TO CONTROL THE FLOW OF STEAM. Steam must be free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. Inrush Dimension In A B C D UL Listed Valves - Consult Factory Not available for operation / -1/ -/ -3/ 9-3/ -3/ / 13-3/4 5-/ 6-/ 6 6-5/ - 6-3/4-3/4-3/4-1/ 9-1/ -3/4 9-3/4-1/ - 2-/ 2-/ 3-1/4 3-5/ / 5-3/ 5-/ 6-5/ 3-1/4 3-1/ / / 4-/ 6 6-1/4-3/ D(Flanged) 1# 4-3/ /4 9- Voltage ( or ) 12 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

13 BULLETIN 6-SR BRONZE SOLENOID VALVES TYPE SR FULL PORT - NORMALLY OPEN TO 3 PIPE SIZE Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Poppet Stainless Steel *Stem Stainless Steel *Springs - Inconel and 302 Stainless Steel *Body Seal - Non Asbestos Gasket *Orifice Seal - Glass Filled Teflon * Shading Coil - Copper *Stem Pin Stainless Steel Coil - Encapsulated Class H, leads TO CONTROL THE FLOW OF STEAM. Steam must be free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. Voltage ( or ) Max / / SR22 4SR42 129SR42 14SR 4SR43 129SR43 16SR14 6SR24 6SR44 131SR44 1SR15 SR 132SR 1SR SR16 SR26 1SR46 141SR46 36SR1 36SR2 42SR4 142SR4 43SR 43SR2 43SR4 143SR4 44SR19 44SR29 44SR49 144SR Hold Inrush UL Listed Valves - Consult Factory Not available for operation 0 F FOR OPTIONS & CESSORIES Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey Dimension In A B C D -1/ 9-1/ -1/ 9-1/4 9-1/ 9-3/4-3/4-3/ -5/ 12-3/ 12-5/ 6-1/ -3/4-5/ -1/ 9-1/ 9-3/ 9-9-3/4-1/ -3/ 2-/ 2-/ 3-1/4 3-5/ / 5-3/ 3-1/4 3-1/4 4-1/ 4-1/ / 4-/ 1-3/4 5-/ -1/4 6 6 D(Flanged) 1# 4-3/ / / -1/ 6-5/ -3/ 9-

14 BULLETIN 6-L BRONZE SOLENOID VALVES 0 F Except valves listed for 0 TYPE L FULL PORT - NORMALLY CLOSED TO 3 PIPE SIZE Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPT conduit conn. *Pilot Valve Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Glass Filled Teflon * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class H, leads FOR OPTIONS & CESSORIES FOR STEAM APPLICATIONS SEE BULLETIN 6-S Page 12 To control the flow of Hot Liquids, Hot Gases, Cryogenics** and any other fluids not reactive with construction materials and free of sediment. Cryogenic fluids include Liquid Oxygen (-29 F), Liquid Argon (-303 F) and Liquid Nitrogen (-320 F). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 3/ / Max L42 14L32 29L52 E29L62 14L 14L43 29L 129L53 Hold Inrush Dimension In D(Flanged) A B C D 1# 5-/ 2-/ 3-1/4 4-3/4 6-/ 3-1/4 6-/ 4 3-1/4-1/ 6 2-/ 5- -1/ E129L / 4 16L L / 3-1/4 4-1/ 31L L / - 4-1/ 0 E131L / / 90 1L 1L / 6-3/4 4-32L L / -3/4 3-5/ 4-0 1L / -3/ L26 L46 41L36 141L / 9-1/ / 4-/ 0 141L L2 36L4 42L3 42L L L2 43L4.0 43L L L L49 44L39 144L Not available for operation /4 9-3/4 5-3/ 5-3/ / -1/ 5-/ -1/ /4-6-5/ -3/ /4 9- ** CLEANING Cryogenic valves are degreased & cleaned to keep them free of moisture. Oxygen valves are also black light tested. Voltage ( or ) 14 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

15 BULLETIN 6-LR BRONZE SOLENOID VALVES TYPE LR FULL PORT - NORMALLY OPEN TO 3 PIPE SIZE Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seal it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. 0 F Except valves listed for 0 ** CLEANING Cryogenic valves are degreased & cleaned to keep them free of moisture. Oxygen valves are also black light tested. Voltage ( or ) 3/ / CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPT conduit conn. *Poppet Stainless Steel *Stem Stainless Steel *Springs - Inconel and 302 Stainless Steel *Body Seal - Non Asbestos Gasket *Orifice Seal - Glass Filled Teflon * Shading Coil - Copper *Stem Pin Stainless Steel Coil - Encapsulated Class H, leads FOR OPTIONS & CESSORIES FOR STEAM APPLICATIONS SEE BULLETIN 6-SR Page 13 To control the flow of Hot Liquids, Hot Gases, Cryogenics** and any other fluids not reactive with construction materials and free of sediment. Cryogenic fluids include Liquid Oxygen (-29 F), Liquid Argon (-303 F) and Liquid Nitrogen (-320 F). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. Max LR42 14LR32 29LR52 E29LR62 14LR 14LR43 29LR 129LR53 Hold Inrush Dimension In A B C D -1/ 9-1/ 9-1/ -1/4-1/ 2-/ 4 2-/ 3-1/4 3-1/4 3-1/ /4-1/ 0 E129LR /4-1/ LR24 16LR / -3/4 3-1/4 4-1/ 31LR LR / 4-1/ 0 E131LR / 4 4-1/ 90 1LR 1LR /4-1/ 4-32LR 132LR /4 9-1/ 3-5/ 4-0 1LR LR26 5 LR46 41LR36 141LR LR LR2 36LR4 42LR3 42LR / / 9-3/ 4 4-/ / 9-3/4 4-4-/ LR LR2 1 43LR LR3 143LR LR LR LR39 144LR Not available for operation / 12-5/ -1/ -3/ 5-3/ 5-3/ 1-3/4 5-/ -1/ / -1/ 6-5/ -3/ 6 6 D(Flanged) 1# 4-3/ /4 9- Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 15

16 BULLETIN 6-G BRONZE SOLENOID VALVES 212 F 1 TYPE G FULL PORT - NORMALLY CLOSED 1 TO 3 PIPE SIZE Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. FOR OPTIONS & CESSORIES 1 1-1/ Max G24 1G24 1G24 G 1G 1G G26 1G26 1G26 G2 1G2 3G2 43G2 143G2 44G29 144G UL Listed Valves - Consult Factory CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve Stem Stainless Steel *Pilot Valve Disc Holder - Brass *Pilot Valve Seal - Buna N (Viton available) *Spring Stainless Steel *Body Seal - Buna N or Non Asbestos Gasket *Orifice Seal - Buna N (Viton or Glass Filled Teflon available) * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, leads - (Class H available) To control the flow of Water, Air, Gas, Solvents, Vacuum and any other fluids not reactive with construction materials and free of sediment. Buna N seating of the pilot and main orifices make the valves ideal for TIGHT SEATING, LOW PRESSURE and LOW FLOW conditions. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. Hold Inrush Dimension In A B C D / -1/ -1/ 9-1/ 9-/ 9-/ 9-/ 12-1/ 12-1/ / 6-1/ -1/ 6-3/ 6-3/ -3/ / -/ -/ -5/ 9-5/ 2-3/4 2-3/4 2-/ 2-/ 3-1/ 3-1/ 3-3/4 3-3/4 3-3/4 5-/ 5-/ 6-5/ 6-5/ 4-1/ 4-1/ 4-1/ 4-3/ 4-3/ 4-3/ 4-3/4 4-3/4 4-3/4 5-3/4 5-3/4 5-3/4 -/ -/ D(Flanged) 1# 6-3/4-3/4 13-5/16 Voltage ( or ) 16 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

17 BULLETIN 6-GR BRONZE SOLENOID VALVES TYPE GR FULL PORT - NORMALLY OPEN 1 TO 3 PIPE SIZE Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. 212 F 1 CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve Stem Stainless Steel *Pilot Valve Disc Holder - Brass *Pilot Valve Seal - Buna N (Viton available) *Spring Stainless Steel *Body Seal - Buna N or Non Asbestos Gasket *Orifice Seal - Buna N (Viton or Glass Filled Teflon available) * Shading Coil - Copper *Stem Pin - Inconel To control the flow of Water, Air, Gas, Solvents, Vacuum and any other fluids not reactive with construction materials and free of sediment. Buna N seating of the pilot and main orifices make the valves ideal for TIGHT SEATING, LOW PRESSURE and LOW FLOW conditions. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. FOR OPTIONS & CESSORIES Voltage ( or ) 1 1-1/ Max GR24 GR24 GR GR GR26 GR26 GR2 1GR2 43GR2 44GR29 Hold Inrush Dimension In A B C D -5/ 9-5/ 9-3/ -1/ /4-1/4 12-3/4 13-5/ -1/4-1/4-3/4-3/4 -/ -/ 9-1/4 9-1/4-1/4-5/ 2-3/4 2-3/4 2-/ 3-1/ 3-3/4 3-3/4 5-/ 6-5/ 4-1/ 4-1/ 4-3/ 4-3/ 4-3/4 4-3/4 5-3/4 5-3/4 -/ D(Flanged) 1# 6-3/4-3/4 13-5/16 UL Listed Valves - Consult Factory Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 1

18 BULLETIN 6-D BRONZE SOLENOID VALVES 212 F 1 TYPE D FULL PORT - NORMALLY CLOSED 3/ TO 2 PIPE SIZE Valve opens when energized and closes when de-energized. In this direct acting valve the disc holder assembly is lifted from its seat by the plunger. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Disc Holder - Brass Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. n. *Stem Stainless Steel *Spring Stainless Steel *Body Seal - Buna N *Orifice Seal - Buna N (Viton or Glass Filled Teflon available) * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, leads - (Class H available) FOR OPTIONS & CESSORIES To control the flow of Water, Air, Gas, Solvents, Vacuum and any other fluids not reactive with construction materials and free of sediment. Buna N seating of the main orifice make the valves ideal for TIGHT SEATING, LOW PRESSURE and LOW FLOW conditions. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 3/ 3/ /4 1-2 Max D D D12 D12 D13 D13 D14 D14 D15 D15 D16 D16 D1 1D1 Hold Inrush Dimension In A B C D 6-1/4-1/ 6-1/4-1/4 6-/ -3/ / -1/ 9-1/ 9-/ 9-/ 5-3/ 6-3/ 5-6-3/ 5-3/4 6-3/4 6-1/ -1/ 6-3/ -3/ / -/ 2-3/4 2-3/4 2-3/4 2-3/4 2-/ 3-1/ 3-3/4 3-3/4 D(Flanged) 1# 2-/ 2-/ 3-1/ 3-1/ 4-3/ / 4-1/ 6-3/4 4-3/ 4-3/ 4-3/4 4-3/4-3/4 5-3/4 5-3/4 Voltage ( or ) UL Listed Valves - Consult Factory Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

19 BULLETIN 6-STN-Y STRAINERS Bronze Stainless Steel The presence of foreign particles in an automatic valve may seriously affect its dependability. The installation of a strainer close to the inlet side of the valve is the best means of preventing the entrance of pipe chips, scale, rust, pipe dope, welding slag or sediment into the valve, provided the screen is periodically removed for cleaning. CONSTRUCTION: Strainer bodies have screwed ends. Screens are stainless steel with opening sizes as listed in tables below. Other sizes can be furnished upon request. Liberal straining area provides for fluid passage at minimum pressure drop. Screens are easily removed for cleaning. furnished with NPT blow-off connections unplugged. See charts below for blow-off sizes (C Dim.) CLEANING FOR CRYOGENIC & OXYGEN SERVICE: Strainers for Cryogenic applications are degreased and cleaned to keep them free of moisture. Strainers for Oxygen service are degreased and cleaned then black light tested. BRONZE 1/4 TO 3 PIPE SIZE Screen Dimensions In 1/4 BR 0 3/4 2-3/4 2-1/4 1/4 3/ Mesh BR 1 3/4 2-3/4 2-1/4 1/ BR 2 3/4 2-3/4 2-1/4 1/4 3/4 Openings BR /16 3/ 1 BR 4 2-1/4 3-3/4 2-3/4 3/ 1-1/4 BR 5 3-1/4 4-/16 3-5/ 3/ Diameter BR /16 3-/ 3/4 2 Perforations BR 6-1/ 5-1/16 1 Lined With 2-30 Mesh BR / /4 3 BR /4 1- A B C STAINLESS STEEL TO 2 PIPE SIZE Screen Dimensions In Mesh SS / 1/4 3/ SS 3 2-1/4 3-3/4 2-13/16 3/ 1 Openings SS 4 3-1/4 4-5/ 3-1/ 3/ Diameter SS 6 6-3/4 5-5/ 4-3/4 3/4 Perforations 2 Lined w/30 Mesh SS A B C PRESSURE TEMPERATURE RATINGS MATERIAL STEAM LIQUIDS 0 F 0 F STAINLESS F 0 F Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 19

20 BULLETIN 6-J STAINLESS STEEL SOLENOID VALVES 0 F TYPE J - NORMALLY CLOSED 3/ TO PIPE SIZE DIRECT TING - ORIFICE SIZES 1/ TO 3/ Valve opens when energized and closes when de-energized. In this direct acting valve, when the coil is energized, the stem is lifted from its conical seat by the plunger. CONSTRUCTION: (*Wetted parts) *Valve Body Stainless Steel Globe Pattern - NPT ends Coil Enclosure - Malleable Iron, NPT conduit conn. *Valve Stem Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Metal to Metal * Shading Coil - Silver *Stem Pin - Inconel Coil - Encapsulated Class H, leads FOR OPTIONS AND CESSORIES 3/ Max. Valve Port 3/ J21 5 3/16 J51 1 1/ J61 3/ J21 1 3/16 J51 1/ J61 3/ J22 5 3/16 J52 1 1/ J62 3/ J22 1 3/16 J52 1/ J62 To control the flow of Steam, Hot Liquids, Hot Gases, Cryogenics and any other fluids not reactive with construction materials and free of sidement. Cryogenic fluids include liquid oxygen (-29ºF), liquid argon(-303ºf) and liquid nitrogen (-320ºF). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. Hold Inrush A Dimensions In /4 5-2-/ 2-3/ / 6-3/ 2-3/ /4 5-2-/ 2-3/ / 6-3/ 2-3/4 Optional Soft Seat Orifice Seal: (for applications requiring tight seating): Viton - Suitable for Fuel Oils, Gaseous Oxygen and other compatible fluids B C D ** CLEANING Cryogenic valves are degreased & cleaned to keep them free of moisture. Oxygen valves are also black light tested. Voltage ( or ) 20 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

21 BULLETIN 6-JR STAINLESS STEEL SOLENOID VALVES TYPE JR - NORMALLY OPEN 3/ TO PIPE SIZE DIRECT TING - ORIFICE SIZES 1/ TO 3/ Valve closes when energized and opens when de-energized. In this direct acting valve, when the coil is energized, the stem is pressed into its conical seat by the plunger. 0 F ** CLEANING Cryogenic valves are degreased & cleaned to keep them free of moisture. Oxygen valves are also black light tested. Voltage ( or ) 3/ CONSTRUCTION: (*Wetted parts) *Valve Body Stainless Steel Globe Pattern - NPT ends Coil Enclosure - Malleable Iron, NPT conduit conn. *Poppet Stainless Steel *Stem Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Metal to Metal * Shading Coil - Silver *Stem Pin - Inconel Coil - Encapsulated Class H, leads To control the flow of Steam, Hot Liquids, Hot Gases, Cryogenics and any other fluids not reactive with construction materials and free of sidement. Cryogenic fluids include liquid oxygen (-29ºF), liquid argon (-303ºF) and liquid nitrogen (-320ºF). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. Max. Valve Port 3/ JR21 0 3/16 JR51 1 1/ JR61 3/ JR21 1 3/16 JR51 1/ JR61 3/ JR22 0 3/16 JR52 1 1/ JR62 3/ JR22 1 3/16 JR52 1/ JR62 Hold Inrush A FOR OPTIONS AND CESSORIES Dimensions In /4 2-/ 2-3/ / -1/ 2-3/ /4 2-/ 2-3/ / -1/ 2-3/4 Optional Soft Seat Orifice Seal: (for applications requiring tight seating): Viton - Suitable for Fuel Oils, Gaseous Oxygen and other compatible fluids B C D Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 21

22 22 0 F Except valves listed for 0 FOR OPTIONS & CESSORIES 3/ Max. 1 14K42 14K32 BULLETIN 6-K STAINLESS STEEL SOLENOID VALVES TYPE K FULL PORT - NORMALLY CLOSED TO 3 PIPE SIZE Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. Hold Inrush CONSTRUCTION: (*Wetted parts - No Copper Bearing Alloys in contact with fluid) *Valve Body Stainless Steel Globe Pattern - NPT ends (For Flanged Ends see Options page 24) *Piston Stainless Steel Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Glass Filled Teflon * Shading Coil - Silver *Stem Pin - Inconel Coil - Encapsulated Class H, leads To control the flow of Corrosive Fluids, Deionized Water, Condensate, Ammonias, Vegetable Oils, Fuel Oils, Cryogenics**, Flammable Liquids. Cryogenic fluids include liquid oxygen (-29ºF), liquid argon (-303ºF) and liquid nitrogen (-320ºF). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. ping Weights above apply to Threaded Ends Only (except 3 which are Flanged Only) For Flanged Ends contact factory for complete weight and dimensions 3 STAINLESS STEEL VALVES ARE SUPPLIED WITH FLANGED ENDS ONLY A Dimensions In FOR STEAM APPLICATIONS SEE BULLETIN 6-W Page 22 Voltage ( or ) Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 B C D NPT D (Flanged) 1# # / 2-/ 0 29K52 E29K / 4 3-1/ K / 6 2-/ K / 0 E129K K K / 3-1/4 31K / / K54 E131K K / 4 41K / K / K K /4 42K3 42K /4 5-3/ K K49F K39F1 13-3/4-6-5/ 144K59F ** CLEANING Cryogenic valves are degreased & cleaned to keep them free of moisture. Oxygen valves are also black light tested.

23 BULLETIN 6-KR STAINLESS STEEL SOLENOID VALVES TYPE KR FULL PORT - NORMALLY OPEN TO 3 PIPE SIZE Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. CONSTRUCTION: (*Wetted parts - No Copper Bearing Alloys in contact with fluid) *Valve Body Stainless Steel Globe Pattern - NPT ends (For Flanged Ends see Options page 24) *Piston Stainless Steel Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Poppet Stainless Steel *Stem Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Glass Filled Teflon * Shading Coil - Silver *Stem Pin Stainless Steel Coil - Encapsulated Class H, leads To control the flow of Corrosive Fluids, Deionized Water, Condensate, Ammonias, Vegetable Oils, Fuel Oils, Cryogenics**, Flammable Liquids. Cryogenic fluids include liquid oxygen (-29ºF), liquid argon (-303ºF) and liquid nitrogen (-320ºF). Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. ** CLEANING Cryogenic valves are degreased & cleaned to keep them free of moisture. Oxygen valves are also black light tested. Voltage ( or ) 3/ FOR STEAM APPLICATIONS SEE BULLETIN 6-WR Page 0 F Except valves listed for 0 FOR OPTIONS & CESSORIES Max. Dimensions In Hold Inrush D (Flanged) A B C D 1# # 1 14KR42 14KR / 2-/ 29KR / 0 E29KR / KR /4-1/ 2-/ 29KR KR /4-1/ 0 E129KR KR / -3/4 3-1/4 31KR / KR / 0 E131KR KR / KR / KR / 9-3/ KR KR / -1/ 42KR3 42KR / -3/ 5-3/ KR KR49F1 44KR39F / -1/ 6-5/ 9-144KR59F ping Weights above apply to Threaded Ends Only (except 3 which are Flanged Only) For Flanged Ends contact factory for complete weight and dimensions 3 STAINLESS STEEL VALVES ARE SUPPLIED WITH FLANGED ENDS ONLY Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

24 BULLETIN 6-W STAINLESS STEEL SOLENOID VALVES 0 F TYPE W FULL PORT - NORMALLY CLOSED TO 3 PIPE SIZE Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. 3/ FOR OPTIONS & CESSORIES Max. Hold Inrush CONSTRUCTION: (*Wetted parts - No Copper Bearing Alloys in contact with fluid) *Valve Body Stainless Steel Globe Pattern - NPT ends (For Flanged Ends see Options page 24) *Piston Stainless Steel Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Glass Filled Teflon * Shading Coil - Silver *Stem Pin - Inconel Coil - Encapsulated Class H, leads To control the flow of STEAM. Steam must be free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top W22 4W / 2-/ 3-1/ W / 1 14W 4W / 6 2-/ W / 16W W24 6W / 3-1/ W / - W16 W / W W / 4-36W1 36W / W4 142W /4 44W19F1 44W29F W49F W49F A Dimensions In B C D D (Flanged) 1# 4-1/ 6-4-/ 6-5-3/ /4-6-5/ 9- ping Weights above apply to Threaded Ends Only (except 3 which are Flanged Only) For Flanged Ends contact factory for complete weight and dimensions 3 STAINLESS STEEL VALVES ARE SUPPLIED WITH FLANGED ENDS ONLY Voltage ( or ) 24 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

25 BULLETIN 6-WR STAINLESS STEEL SOLENOID VALVES TYPE WR FULL PORT - NORMALLY OPEN TO 3 PIPE SIZE Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and seat it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. CONSTRUCTION: (*Wetted parts - No Copper Bearing Alloys in contact with fluid) *Valve Body Stainless Steel Globe Pattern - NPT ends (For Flanged Ends see Options page 24) *Piston Stainless Steel Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Poppet Stainless Steel *Stem Stainless Steel *Spring - Inconel *Body Seal - Non Asbestos Gasket *Orifice Seal - Glass Filled Teflon * Shading Coil - Silver *Stem Pin Stainless Steel Coil - Encapsulated Class H, leads 0 F To control the flow of STEAM. Steam must be free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. Voltage ( or ) 3/ Max. Hold Inrush FOR OPTIONS & CESSORIES WR22 4WR / 2-/ 3-1/ WR / 1 14WR 4WR /4-1/ 2-/ WR /4-1/ 16WR WR24 6WR / -3/4 3-1/ WR / WR16 WR / WR WR / 9-3/4 4-36WR1 36WR / -1/ WR4 142WR / -3/ 44WR19F1 44WR29F WR49F WR49F / 6-4-/ 6-5-3/ / -1/ 6-5/ 9- Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 A Dimensions In B C D D (Flanged) 1# ping Weights above apply to Threaded Ends Only (except 3 which are Flanged Only) For Flanged Ends contact factory for complete weight and dimensions 3 STAINLESS STEEL VALVES ARE SUPPLIED WITH FLANGED ENDS ONLY

26 BULLETIN 6-OPT OPTIONAL FEATURES For Solenoid Valves See Individual Options For Availability For Use With Specific Valve Types BOTTOM MOUNTED OPTIONS Note: Only One Bottom Mount Option Can Be Installed On Each Valve MANUAL OVERRIDE (Normally Closed valves only) (Designated by Prefix MO ) Enables manual opening of solenoid valve during power failure or to override automatic controls. DASHPOT (Designated by Prefix DP ) Furnished for clean liquids to reduce water hammer effect sometimes encountered in long pipe runs by slowing valve closing. LEVER (Normally Closed valves only) (Designated by Prefix LV ) Enables rapid opening of solenoid valve. Can be chain operated for use at inaccessible locations. FLOW CONTROL (Normally Closed, NR & MR valves, only) (Designated by Prefix FC ) Provides a manual method of reducing or throttling the flow. MOUNTING STUD (Designated by Prefix MS ) 3/ -16 thread can be furnished in bottom of body to facilitate mounting on bracket. (Not available on 2, 2- and 3 ) DRAIN (Normally Closed, NR & MR valves, only) (Designated by Prefix DR ) - 1/4 NPT plug supplied in bottom of valve to facilitate draining of liquid OTHER OPTIONS PILOT TAP (Designated by Prefix PT ) Type D, G & GR Valves can be furnished with 1/ tapped hole for pilot connection or pressure gauge. DIN CONNECTOR (Designated by Suffix DN ) Provides 3 prong connector for easy power connect / disconnect. Not available for Explosion-Proof. 26 HUM FREE : (No Hum/Buzz) (Designated by Suffix HF ) - The HUM FREE option eliminates the hum associated with operated solenoid valves. Enables valves to be used where an hum would not be acceptable and is the only power source available. IE: Hospitals, labs, schools (class rooms), homes, office environments etc. & when 24 vac is required for series valves. Leak / Dead Tight: (Normally Closed valves only) (Designated by Suffix LT ) - The Leak / Dead Tight Option offers soft resilient seating or gapless seal for low pressure applications or less. Consult Factory for Max. Pressure and Valve Type availability. Flanged Ends for Bronze and Stainless Steel Valves: (Designated by Suffix F1 for 1 lb or F3 for lb Flanges) F1 or F3 Flanged ends available on all stainless steel valves. F1 Flanged ends available on bronze valves. F3 Flanged ends for bronze valves available through our Clark-Cooper Division. Explosion-Proof and Watertight Solenoids: (Designated by Prefix F ) are Explosion-proof and NEMA 4, C & D, 9E, F & G suitable for use in hazardous locations requiring Class I, Groups C & D & Class II Groups E, F, and G equipment. NEMA 4X: (Designated by Prefix F AND Suffix ZP ) are suitable for use in locations requiring a NEMA 4X designation. ZP (Zinc Plating) replaces the standard paint used on the Coil housing (cup and base). The additional corrosion protection satisfies NEMA 4X requirements. Internal construction, pressure ratings, power consumption, and external dimensions are the same as for standard valves. Nickel Plating: (Designated by Suffix NP ) - Plating is Thick Meets Mil Spec. C24 Universal Mount Valves For Mounting In Vertical Runs (See Magnatrol Universal Mount Catalog 6-UM) Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

27 BULLETIN 6-POS/IND POSITION INDICATORS For Normally Closed Solenoid Valves Position Switches CONSTRUCTION: Housing Stainless Steel with NPT Conduit Connection Contact - SPDT (Single Pole/Double Throw) Lead Wires - 36 inches long, gauge standard leads potted-in PVC Switch is activated by a ferromagnetic target attached to the valve s piston PS - General Purpose/NEMA 4, 4X PSF - Explosion Proof SPDT Contact Electrical Rating: 120 V / 24 V 2 V / 4 V 1 V & 0 V PS shown with valve body adaptor The PS and PSF can be wired or, N/O or N/C, consume no power to operate, and leave no current leakage or voltage drop PS General Purpose & Water Tight (SPDT Switch) shown on 3 Stainless Steel Valve Position Switches With LED Visual Indication Position Switch on right shown energizing Red LED PL - General Purpose/NEMA 4, 4X PLF - Explosion Proof SPDT Contact Electrical Rating: 120 V / 24 V 120 V / 24 V without the LEDs) The PL and PLF can be wired or, N/O or N/C Ambiant Temperature: - F to 221 F (6 C) NOTE: ONLY ONE BOTTOM MOUNTED OPTION CAN BE INSTALLED ON EH VALVE For multiple switches and where a switch and a bottom mounted option are required, contact our Clark Cooper Division. (See bottom of Page 3) Position Display - Visual Indication ONLY PD - General Purpose / NEMA 4, 4X / Explosion Proof CONSTRUCTION: Housing - Clear High-Strength Polycarbonate Visual indication that valve is Open / Closed When the valve is in the closed position, a ferromagnetic target attached to the valve s piston, lifts a green colored magnet into the adapter hiding it from view. When the valve is energized, (open position), the magnet drops down to a visible position. Position Indicators for Normally Closed Valve Only Available on Type A, S, L, K, W & G Valves HOW TO ORDER: Indicate Option when Ordering: Use the appropriate Prefix: PS, PSF, PL, PLF, or PD Example: PSA44 indicates a Position Switch mounted on a Type A44 valve. Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 2

28 BULLETIN 6-UNIVERSAL MOUNT/ANY POSITION BRONZE SOLENOID VALVES 212 F Except valves listed for 0 TYPE P FULL PORT - NORMALLY CLOSED TO 1- PIPE SIZE Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable Iron, NPS conduit conn. *Plunger Spring Stainless Steel *Pilot Valve Stainless Steel *Spring Stainless Steel *Body Seal - Buna N or Non Asbestos Gasket *Orifice Seal - Buna N (Viton or Glass Filled Teflon available) * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, leads To control the flow of Water, Oil, Air, Gas, Solvents, Brine, Vacuum and any other fluids not reactive with construction materials and free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. Valve can be mounted in ANY POSITION (See box at right). The P Valve is: Multipoised: Ability to be mounted in any position. Spring Loaded: The term used to indicate that the valve has a plunger spring. A spring-loaded plunger permits the valve to be mounted in any position without causing malfunction. 3/ Max P42HF 1P32HF 1P52HF 1PHF 1P43HF 1PHF 1P53HF 1P24HF 1P44HF 1P34HF 1P54HF 41P46HF 41P36HF 41P56HF Dimension In A B C D / -/ 5-/ 6 6-5/ 2-3/4 2-3/4 4-1/ 2-3/4 -/ - 3-1/4 4-1/ 9-1/ 4-4-/ FOR OPTIONS & CESSORIES Voltage ( or ) Explosion Proof: Available for Power Source ONLY (Valves without HF suffix). Use Prefix F (i.e. F1P44). 2 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

29 BULLETIN 6-SANDY WELL WATER BRONZE SOLENOID VALVES SANDY WELL WATER FULL PORT - NORMALLY CLOSED TO 3 PIPE SIZE Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve Stainless Steel *Spring Stainless Steel *Body Seal - Buna N or Non Asbestos Gasket *Orifice Seal - Buna N (Viton or Glass Filled Teflon available) * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, leads - (Class H available) To control the flow of Sandy Well Water, the valve is designed with the piston and other components turned down, offering additional clearance, allowing the valve to operate with fluids containing some sediment typically found in well water. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 212 F Except valves listed for 0 FOR OPTIONS & CESSORIES Voltage ( or ) 3/ / Max A22-V 1A22-V A-V 1A-V 3A-V A24-V 1A24-V 1A24-V 3A24-V A-V 1A-V 1A-V 1A-V A26-V 1A26-V 41A26-V 36A1-V 136A1-V 136A2-V 42A2-V 142A2-V 43A-V 143A-V 243A-V 44A19-V 144A19-V 244A19-V Dimension In A B C D / 2-3/4 3-1/4-1/ 6 2-3/4-1/ -/ 6-5/ 2-3/4 4-1/ -/ - 2-3/4 4-1/ -3/ 6-3/4 2-3/ / -3/ / 4 4-/ 9-1/ 4-4-/ -3/4 5-3/ /4 5-3/ 6 12-/ -1/ 5-/ -1/4 13-3/4-6-5/ -3/ Not available for operation Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 29

30 BULLETIN 6-GRITTY COOLANT/NORMALLY CLOSED BRONZE SOLENOID VALVES 212 F Except valves listed for 0 GRITTY COOLANT FULL PORT - NORMALLY CLOSED TO 1- PIPE SIZE Valve opens when energized and closes when de-energized. When the coil is energized the pilot valve opens, relieving the pressure above the piston, which is then lifted from its seat by the plunger. Upon de-energizing the coil, a spring closes the pilot valve and opens a bleed passageway to permit pressure to build above the piston and seat it. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Pilot Valve Stainless Steel *Spring Stainless Steel *Body Seal - Buna N or Non Asbestos Gasket *Orifice Seal - Buna N (Viton or Glass Filled Teflon available) * Shading Coil - Copper *Stem Pin - Inconel Coil - Encapsulated Class B, leads - (Class H available) To control the flow of Coolant, the valve is designed with the piston turned down and a larger pilot port, offering additional clearance, allowing the valve to operate with fluids containing some grit/sediment typically found in coolant. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 3/ /4 1- Max MSA42-C MSA22-C MS3A42-C MSA43-C MSA-C MS1A-C MS3A43-C MS3A24-C MS3A44-C MS3A-C MS3A-C MS241A46-C Dimension In A B C D 5-/ 2-3/4 3-1/4 A Dimension does not include the MS Mounting Stud (Approx. / ) Note: The addition of any bottom mounted option would replace the MS Mounting Stud and change the prefix to reflect the appropriate option / 6 2-3/4-1/ -/ 6-5/ 2-3/4 4-1/ -3/ 6-3/4 2-3/ / 4 4-/ FOR OPTIONS & CESSORIES Voltage ( or ) Not available for operation 30 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

31 BULLETIN 6-GRITTY COOLANT/NORMALLY OPEN BRONZE SOLENOID VALVES GRITTY COOLANT FULL PORT - NORMALLY OPEN TO 1- PIPE SIZE Valve closes when energized and opens when de-energized. When the coil is energized the plunger presses the poppet, closing the pilot orifice, and opens a bleed passageway to permit pressure to build above the piston and sealing it. Upon de-energizing the coil, the pilot orifice is opened, relieving the pressure above the piston, allowing it to leave its seat. The bottom spring allows the valve to operate at zero pressure drop. CONSTRUCTION: (* Wetted parts) *Valve Body - Cast Bronze, Globe Pattern - NPT ends *Piston - Cast Bronze Coil Enclosure - Malleable or Cast Iron, NPS conduit conn. *Poppet Stainless Steel *Stem Stainless Steel *Spring - Inconel and 302 Stainless Steel *Body Seal - Buna N or Non Asbestos Gasket *Orifice Seal - Buna N (Viton or Glass Filled Teflon available) * Shading Coil - Copper *Stem Pin Stainless Steel Coil - Encapsulated Class B, leads - (Class H available) To control the flow of Water, Oil, Air, Gas, Solvents, Brine, Vacuum and any other fluids not reactive with construction materials and free of sediment. Valve operates from zero to maximum differential pressure indicated in table. Valve must be mounted in horizontal pipe with solenoid enclosure vertical and on top. 212 F Except valves listed for 0 FOR OPTIONS & CESSORIES 3/4 1 Max 1 1 MSAR42-C MSAR-C MS3AR43-C MSAR44-C MS3AR24-C MS3AR44-C Dimension In A B C D 9-3/ -1/4 4-1/ 3-1/4 9-1/4-1/ 2-3/ /4-1/ A Dimension does not include the MS Mounting Stud (Approx. / ) 14-5/ 4-1/ Voltage ( or ) Note: The addition of any bottom mounted option would replace the MS Mounting Stud and change the prefix to reflect the appropriate option. Not available for operation Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0 31

32 BULLETIN 6 - RFQ REQUEST A QUOTE Fill In The Information Below If you have any questions or wish to request a quote: Phone: Fax: info@magnatrol.com We appreciate the opportunity to quote on your requirements. For immediate quote Fill in the information below and CALL: For same day quote Fill in the information below and FAX: For quote within 24 hrs Go online to and go to Quick Quote YOUR COMPANY DATA Company Name: Phone: Contact (Your Name): Fax: Your RFQ Reference (If Any): Type of Business: OEM Re-Seller Consumer/End User VALVE DATA Desired Delivery: Your Reference (Optional): Quantity: Valve Construction Material: Bronze or Stainless Steel : (1/4 thru 3 ): Normally: Closed (Energize To Open) or Open (Energize To Close) Voltage: : Volts/ Hz or : Volts Maximum Differential Pressure: Fluid: Maximum Fluid Temperature: F Optional Feature: (See Optional Feature Details On Pages 26 & 2) Choose One (1) Of The Following Per Valve: MO LV DP FC MS DR PD PS PL Additional Options: HF LT NP PT DN ZP (Can be combined with one (1) of the above Optional Features) Enclosure Options: General Purpose Explosion Proof NEMA 4 NEMA 4X (For Solenoid Housing) (Prefix G - NEMA 12) (Prefix F ) (Prefix E ) (Prefix E & Suffix ZP ) Comments: Quantity Discounts: Consult Factory Delivery: Most orders ship in - days. Small emergency orders can be shipped in 1-2 days. 32 Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

33 BULLETIN 6 - ORDER GUIDELINES ORDERING GUIDELINES Magnatrol Solenoid Valves If you have any questions or wish to request a quote: Phone: Fax: info@magnatrol.com MAGNATROL VALVE TYPE NUMBER DETAIL For Additional Information On Options See Optional Features Pages 26 & 2 PREFIX OPTION FIELD SOLENOID ENCLOSURE FIELD VALVE TYPE NUMBER Refer To Individual Bulletins For Type Number END CONNECTION TYPE VOLTAGE DESC. HERZ DESC. VALVE DISC FLUID FIELD SUFFIX OPTION FIELD(S) (Add As Required) Options: (Choose One) DP - Dashpot (Consult factory for valve type availability) DR - Drain Plug ** FC - Flow Control ** LV - Lever * MO - Manual Override * MS - Mounting Stud PD - Position Display * PL - Position Switch w/led * PS - Position Switch * = == Enclosures: G - General Purpose NEMA12 E - NEMA 4 - NEMA 4X F - Explosion Proof & NEMA 4 === Kerosene, Gasoline, Naptha, Alcohol, Soluable Oil, Coolant, Freon and Refrigerant). * Normally Closed Valves Only End Connection Description: SC - Screwed, FNPT F1-1# Flange F3 - Flanged Voltage Description: A B - 20 C - 2 D - E - 55 F - 6 G - 12 H - 24 ** Normally Closed and NR & MR Valves/FC not available on G valve type Hertz Description: A - / B - C - D - Disc Material: = B - Buna N T - V - Viton M - Metal CR - Clean For Freon/Refrigerant CY - Clean For Oxygen CZ - Clean For Cryogenics DN - Din Connector HF - Hum Free HT - High Temperature Coil LL - 6 Long Lead Wires LT - Leak Tight (Soft Seat Pilot) NP - Nickel Plated (.005 Thickness) Meets Mil Spec C24 PT - Pilot Tap *** RB - Reducing Bushing ZP - Zinc Plated Solenoid Housing Metal Tags: AL - Aluminum Tag SS - Stainless Steel Fluids: C - Gritty Coolant G - Gas/Air/Oxygen H - Hot Liquid == O - Oil/Fuel Oil S - Steam V - Sandy Well Water W - Cold Liquid === Z - Cryogenics/Liquid O2 *** Pilot Tap: Can be used along with any other option. Available On Type D, G and GR only. Consult Factory for Assistance with: Additional voltages End Connections not shown Field designations Check individual bulletins for listed valves Magnatrol Valve Corporation P.O. Box 1 6 Fifth Avenue Hawthorne New Jersey 0

34 BULLETIN 6 - TERMS & CONDITIONS TERMS & CONDITIONS OF SALE CONTT INFORMATION Solenoid valve questions can be answered quickly and accurately over the phone: Phone: Fax: TERMS & CONDITIONS OF SALE Catalog: This catalog supersedes all previous issues. Quotations: Quotations are made for acceptance within days and are subject to change or withdrawal without notice. Prices and Discounts: All prices and discounts are in accordance with the prices and discounts established by Magnatrol and are subject to change without notice. Terms: Net 30 days, subject to establishment of credit. ments: All shipments are F.O.B. factory, Hawthorne, New Jersey. Our responsibility ends with delivery of merchandise to the transportation company and issuance to us of formal shipping receipt. Minimum Billing: Minimum billing charge is $.00 net. Cancellations: Orders are subject to cancellation only with our consent. ping Date: There shall be no liability for default or delay in shipping. All orders, contracts, and agreements are made subject to delays contingent upon accidents, strikes, embargoes or other causes beyond our control. Design and Materials: All materials and designs are subject to change without notice. Weights and Dimensions: Weights and dimensions listed in this catalog are as close to actual as is practicable but are not guaranteed and are subject to change without notice. Errors: All clerical errors are subject to correction. 12. Returns for Repair: Valves retuned for repair must be shipped prepaid and accompanied by a detailed report regarding service application, installation and nature of trouble or malfunction. 13. Returns for Credit: Returns for credit will be accepted only with our consent. Credit will be subject to restocking charge and any additional expenses incurred in restoring valves to salable condition. Credit will be issued only to original purchaser. 14. Taxes: Any manufacturer s excise tax, use tax, sales tax or tax or duty of any nature shall be paid by the buyer. In the event that the seller is required to pay any such taxes or duties, the buyer shall reimburse seller therefore. The buyer may provide seller with an exemption certificate or other documents acceptable to taxing or customs authorities at the time an order is placed. 15. Guarantee: MAGNATROL valves are guaranteed to be free from any defects in material and workmanship for one year or 0,000 cycles, whichever comes first. Our guarantee solely conveys the right to repair or replace free of charge, any defective valves, or parts, thereof, returned to us transportation charges prepaid, within one year after date of original shipment from factory. This guarantee shall not apply if the valve has been: Improperly Installed Used for other than intended service Repaired without authorization Check individual bulletins for listed valves MAGNATROL CONTT INFORMATION Sales, Service, Phone: Tech Support: Fax: info@magnatrol.com techsupport@magnatrol.com Mailing Address: PO Box 1 Hawthorne, NJ 0 ping Address: 21 Horton Avenue Hawthorne, NJ 06 Administrative: 6 Fifth Avenue Hawthorne, NJ 06

WELCOME TO MAGNATROL

WELCOME TO MAGNATROL Catalog 6 BULLETIN 6-INDEX WELCOME TO MGNTROL Process Control Solenoid Valves For Water Oil ir Gas Steam Cryogenics Vacuum Solvents Brine Oxygen Corrosive Fluids Magnatrol Valve Corp. Established 1936

More information

High Pressure Solenoid Valves

High Pressure Solenoid Valves High Pressure Solenoid Valves Available for Quick Delivery Controls the flow of Gases & Liquids up to 15,000 PSIG Natural Gas, Hydrogen & other High Pressure Gases High Pressure Cryogenics Flammable Liquids

More information

Prices Effective April 1, 2017 PRICE BOOK * CHECK ONLINE FOR PRICE BOOK UPDATES

Prices Effective April 1, 2017 PRICE BOOK * CHECK ONLINE FOR PRICE BOOK UPDATES * CHECK ONLINE FOR PRICE BOOK UPDATES PRICE BOOK . Catalog: This catalog supersedes all previous issues. Terms and Conditions of Sale 2. Quotations: Quotations are made for acceptance within 60 days and

More information

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B) 4 Engineering Information Principles of Operation A solenoid valve is a combination of two basic functional units: A solenoid (electromagnet) with its core A valve body containing one or more orifices

More information

Product Manual. EX40, Version Last Updated: 11/7/16. Product Description:

Product Manual. EX40, Version Last Updated: 11/7/16. Product Description: Product Manual EX40, Version 2016.1 Last Updated: 11/7/16 Product Description: The EX40 Series encompasses 2-way piloted solenoid valves with a maximum allowable inlet pressure of 15,000 psi [103.4 MPa].

More information

3 Way/2 Position Valves

3 Way/2 Position Valves Way/ Position Valves Three way valves have three pipe connections and two orifices. When one orifice is open, the other is closed, and vice versa. They are commonly used to alternately apply pressure to

More information

Constructions Suitable for -40 C to -50 C Ambient

Constructions Suitable for -40 C to -50 C Ambient Constructions Suitable for -40 C to -50 C Ambient 2, 3 and 4 Way Constructions Available Brass and Stainless Steel Bodies Air and Inert Gas Service AIR/INERT GAS QUALITY STATEMENT FOR LOW AMBIENT VALVES

More information

2-Way/2 Position Valves

2-Way/2 Position Valves 4 2-Way/2 Position Valves Two-way solenoid valves have one inlet and one outlet, and are used to permit and shut off fluid flow. Two Types of Operations Apply Normally Closed (NC) Fluid is shut off when

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual Technical Manual EH 1.2 General Information about valve sizing: Valves with a Full Port have an internal seat diameter that is the same as the nominal pipe

More information

Size: 1/4 to 3. Material: 316 Stainless Steel, Carbon Steel,

Size: 1/4 to 3. Material: 316 Stainless Steel, Carbon Steel, Size: 1/4 to 4 Material: 316 Stainless Steel, Carbon Steel, Alloy 20, Hastelloy C, Monel, Brass, SW, BW, BSPT, 150#, 300#, 600#, Flanged Pressure: Vacuum to 3000 PSI* -50 to 600 F* ASME B16.34 Design Bottom

More information

Constructions Suitable for -40 C to -50 C Ambient. 2, 3 and 4 Way Constructions Available. Brass, Aluminum and Stainless Steel Bodies

Constructions Suitable for -40 C to -50 C Ambient. 2, 3 and 4 Way Constructions Available. Brass, Aluminum and Stainless Steel Bodies Constructions Suitable for - C to -5 C Ambient, 3 and Way Constructions Available Brass, Aluminum and Stainless Steel Bodies Air and Inert Gas Service INDEX General Service Valves -Way/ Position 8 Aluminum

More information

SECTION VALVES

SECTION VALVES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions Specification Sections, apply to this Section. B. Related Sections:

More information

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017 ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue 2017.1, Released December 13, 2017 Clark Cooper A Division of Magnatrol Valve Corp. 941 Hamilton avenue Roebling,

More information

4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT. Features. Construction.

4 qwer 2/2. Pilot Operated General Service Solenoid Valves. Brass or Stainless Steel Bodies 3/8 to 2 1/2 NPT. Features. Construction. 4 qwer Pilot Operated General Service Solenoid Valves Brass or Stainless Steel Bodies 3/8" to 2 1/2" NPT NC NO 2/2 SERIES Features Wide range of pressure ratings, sizes, and resilient materials provide

More information

SOLENOID CONTROL VALVE

SOLENOID CONTROL VALVE PROJECT NAME LOCATION SOLENOID CONTROL VALVE INTRODUCTION This specification covers the design, manufacture, and testing of 4 in. (100 mm) through 36 in. (900 mm) Control Valves PART 1 - GENERAL 1. Standard

More information

UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F

UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F UNITED ELECTRIC 100 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches Adjustable Ranges 30 Vac to 5000 PSI, -180 to 650 o F DESCRIPTION The 100 Series is a cost-effective pressure and temperature

More information

Technical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE

Technical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE Technical Data SD 4011 SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 TYPE A SERIES AIR ADJUSTED PILOT PRINTED IN U.S.A. SD 4011/9504 Type A or A83 (wt 6 lb) Type A53 or A 85

More information

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures S-SERIES Pressure Switches Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with, or s Features: Set point repeatability, +1% of operating range. All wiring terminals, adjustments

More information

Electronic Control Valves

Electronic Control Valves MODEL 131 Series (Full Internal Port) 631 Series (Reduced Internal Port) Electronic Control Valves Model 131-01/631-01 Simple Proven Design Quality Solenoid Pilot Controls Ideal For SCADA Systems Multi-Function

More information

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE PROJECT NAME LOCATION COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES INTRODUCTION This specification covers the design, manufacture, and testing of 1 in. (25 mm) through 36 in. (900

More information

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No. SECTION 23 22 13 STEAM AND CONDENSATE PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification

More information

check valves BIVCO Check Valves

check valves BIVCO Check Valves BIVCO valves are considered all-purpose valves because they can be tailored in the right combination of materials for the job at hand for liquids, including acids, alkalais, formaldehyde, solvents, oils,

More information

SECTION Pressure & Temperature Control

SECTION Pressure & Temperature Control 16 Pressure & Temperature Control ARMSTRONG PRODUCT CATALOGUE 70 Pressure Reducing s Pressure Reducing s Armstrong pressure reducing valves (PRVs) and temperature regulators help you manage steam, air

More information

15100 VALVES. E. Section Building Automation and Control System Guidelines

15100 VALVES. E. Section Building Automation and Control System Guidelines 15100 VALVES PART 1: GENERAL 1.01 RELATED SECTIONS A. Section 15050 Basic Material and Methods B. Section 15545 Chilled Water System C. Section 15550 Heat Generation D. Section 15790 Coils E. Section 15955

More information

CIRCLE SEAL CONTROLS

CIRCLE SEAL CONTROLS CIRCLE SEAL CONTROLS ATKOMATIC SOLENOID VALVES INSTALLATION, MAINTENANCE, AND OPERATION INSTRUCTIONS 3000 SERIES Bronze, Normally Closed, Direct Lift Installation Instructions WARNING: These instructions

More information

Iron Horse ED Series Pressure Regulator

Iron Horse ED Series Pressure Regulator REGULATORS Applications Pressure Regulation for Steam Distribution Single Point or Multiple Use Applications Pressure Control for Steam Plants District Heating Systems Single Stage Reduction Stations Two

More information

SECTION VALVES PART 1 - GENERAL

SECTION VALVES PART 1 - GENERAL 1.01 RELATED DOCUMENTS SECTION 15100 VALVES PART 1 - GENERAL A. The work in this section includes the furnishing and installation of all control valves and accessories shown on the construction plans and

More information

A. This Section includes general duty valves common to several HVAC piping systems.

A. This Section includes general duty valves common to several HVAC piping systems. SECTION 23 05 23 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating 1/4" NPT VENT 'A' 1/4" NPT 2 - REQ'D 'D' REQ D FOR BASKET REMOVAL 'B' FLOW 'C'

More information

Refrigeration Solenoid Valves & 3-Way Heat Reclaim Valves

Refrigeration Solenoid Valves & 3-Way Heat Reclaim Valves aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Refrigeration Solenoid s & 3-Way Heat Reclaim s Catalog D-1, May 2010

More information

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4 NPT. Features. Construction. Direct Acting Direct Mount Pilot Valves Brass or Stainless Steel Bodies /" NPT / 83 Direct Mount Features NAMUR direct mount version of the rugged, dependable 83 Series valves Direct acting, high flow

More information

Deep Well Pump Control Valve

Deep Well Pump Control Valve MODEL 61-02 661-02 Deep Well Pump Control Valve Prevent Surges in Pipelines Simple Hydraulic Operation Adjustable Opening & Closing Speeds Solenoid Control Can Be Operated Manually Proven Reliable Design

More information

Solenoid Valves for General Purpose 2 Ways

Solenoid Valves for General Purpose 2 Ways 1 127 15 Solenoid Valves for General Purpose 2 Ways 2 19 19 22 2 2 159 1 Normally closed Servo-operated or hung. -4 / -5 127 Normally closed and Normally open Direct acting. - / -7 15 Normally closed and

More information

Technical Information Features Fast Response - Bubble Tight Sealing Small Size - 4 Inches High Single Solenoid - Only 3 Moving Parts Pilot Interchange

Technical Information Features Fast Response - Bubble Tight Sealing Small Size - 4 Inches High Single Solenoid - Only 3 Moving Parts Pilot Interchange Model Number Index Function / Mounting Style N195 4-Way Line Mounting N205 4-Way Non Plug-In Manifold Mounted N215 4-Way Plug-In Manifold Mounted Line Mounting, Non Plug-In, Manifold Mounting Function

More information

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC&R VALVES

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC&R VALVES SECTION 23 05 23 HVAC&R VALVES PART 1 - GENERAL 1.1 SUMMARY: A. Section includes valves for building services piping. 1.2 GENERAL VALVE APPLICATION REQUIREMENTS: A. Provide valve handle extensions that

More information

RESILIENT SEATED BUTTERFLY VALVES. Howell Valve & Automation. Toll Free: Howellvalve.com

RESILIENT SEATED BUTTERFLY VALVES. Howell Valve & Automation. Toll Free: Howellvalve.com RESILIENT SEATED BUTTERFLY VALVES Howell Valve & Automation Toll Free: 1-888-469-3557 Howellvalve.com TABLE OF CONTENTS Description Page Index 2 Resilient Standard Features 3 ST Boot Series with BUNA-N

More information

Specifications, Applications, Service Instructions & Parts. Flanged and Weld-in 3/4" thru 4" Port (20 mm thru 100 mm) for Refrigerants

Specifications, Applications, Service Instructions & Parts. Flanged and Weld-in 3/4 thru 4 Port (20 mm thru 100 mm) for Refrigerants Bulletin Specifications, Applications, Service Instructions & Parts Hs4d TWO STEP solenoid valves Flanged and Weld-in 3/4" thru 4" Port (20 mm thru 100 mm) for Refrigerants 2 (50 mm) HS4D with Optional

More information

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure

More information

CIRCLE SEAL CONTROLS

CIRCLE SEAL CONTROLS CIRCLE SEAL CONTROLS ATKOMATIC SOLENOID VALVES INSTALLATION, MAINTENANCE, AND OPERATION INSTRUCTIONS 13000 SERIES Stainless, Normally Closed, Direct Lift, 3-Way Valve Installation Instructions WARNING:

More information

SECTION MISCELLANEOUS VALVES

SECTION MISCELLANEOUS VALVES SECTION 05140 - PART 1 - GENERAL 1.1 WORK OF THIS SECTION A. The WORK of this Section includes providing miscellaneous valves as indicated, complete and operable, including accessories and operators. 1.2

More information

FILTERS, STRAINERS AND VALVES PRODUCT GUIDE

FILTERS, STRAINERS AND VALVES PRODUCT GUIDE FILTERS, STRAINERS AND VALVES PRODUCT GUIDE TEE FILTERS INLINE FILTERS BRASS FILTERS SPIN ON FILTERS OFF-LINE FILTRATION Y STRAINERS BASKET STRAINERS DUPLEX STRAINERS STRAINING ELEMENTS FRP STRAINERS DUAL

More information

Gasket

Gasket CAST STAINLESS STEEL GATE VALVES API 603 INTEGRAL SEAT, 1 2 1 1 2", (15 40 mm) CLASS 800 GATE VALVES FULL PORT 1 2 1 1 2", (15 40 mm) THREAE OR SOCKET WEL, ASME CLASS 800 Precision High Quality Investment

More information

Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves

Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves Quic-Pics Catalogue Pneumatic Power Valves Series 75/76 Manual, Mechanical, Pneumatic and Electric Valves Contents: Product Line Overviews 2 Manually Operated Valves 5 Pushbuttons 6 Toggle Switch 8 Knob

More information

4 N E X T G E N E R A T I O N

4 N E X T G E N E R A T I O N N X T G N R A T I O N lectronically nhanced Solenoid Valves and Stainless Steel Bodies /" - " NPT / 3/ / SRIS Next Generation Features Increase in DC pressure ratings to AC levels on all products (up to

More information

CUSTOM COMBINATION AIR VALVE

CUSTOM COMBINATION AIR VALVE INSTALLATION / OPERATION / MAINTENANCE CUSTOM COMBINATION AIR VALVE INTRODUCTION This manual will provide you with the information to properly install and maintain this valve to ensure a long service life.

More information

Valve Selection. 1. Function and service considerations

Valve Selection. 1. Function and service considerations 1. Function and service considerations Valve Selection Selection Valves serve the purpose of controlling the fluids in building services piping. Valves are produced in a variety of design types and materials.

More information

Table of Contents. Introduction. Description. Greater Total System Efficiency. Improved Design. Easy Installation and Maintenance

Table of Contents. Introduction. Description. Greater Total System Efficiency. Improved Design. Easy Installation and Maintenance Features & Benefits Table of Contents Features & Benefits................................................................ 13900.1 Scope of Design...................................................................

More information

Crispin Valves Operating Guide. Crispin

Crispin Valves Operating Guide. Crispin Crispin Valves Operating Guide Crispin Since 1905 Crispin Multiplex Manufacturing Co. 600 Fowler Avenue Berwick, PA 18603 1-800-AIR-VALV T: (570) 752-4524 F: (570) 752-4962 www.crispinvalve.com sales@crispinvalve.com

More information

Titan Check Valves. Call. Fax. . Visit. Titan Flow Control. Your Pipeline to the Future

Titan Check Valves. Call. Fax.  . Visit. Titan Flow Control. Your Pipeline to the Future Your Pipeline to the Future TITAN 290 Corporate Drive Lumberton, NC 28358 Titan Check Valves, Inc. is a high quality manufacturer of check valves. With a dedication to great customer service, cutting edge

More information

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING SECTION 220523 - GENERAL-DUTY VALVES FOR PLUMBING PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

MARFAID Solenoid Valves

MARFAID Solenoid Valves Series 125 2-Way Normally Closed Pilot Operated Diaphragm Type Bronze Construction Wide Variety of Voltages Maximum Temperature 190 F Pressure Range 5-150 psi Horizontal or Vertical Installation 1-15 4"

More information

Hoffman Specialty Service Parts Catalog PARTS LIST HS-800C

Hoffman Specialty Service Parts Catalog PARTS LIST HS-800C Hoffman Specialty Service Parts Catalog PARTS LIST HS-800C Hoffman Specialty Table of Contents STEAM TRAPS FLOAT AND THERMOSTATIC SERIES PAGE INVERTED BUCKET SERIES PAGE C 6 B0 H B I B X 6 B 6 8 B 6 0

More information

Technical Data TYPE T124 & T134 TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4512A

Technical Data TYPE T124 & T134 TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4512A WATTS INDUSTRIES, INC. Technical Data SD 4512A SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY 12586-2035 PRINTED IN U.S.A. SD 4512A/9806 T124/T134 PILOT FRONT VIEW 2 1 /16 F 5 7 /8 2 3

More information

Control & Power, Inc

Control & Power, Inc Way/ 2 and 3 Position Four ported valves are generally used to operate double-acting cylinders or actuators. They have four or five pipe connections, commonly called ports: One pressure inlet. Two cylinder

More information

4 qwer. Main Pulse Valves Dust Collector 2/2 SERIES H OME PAGE P RINT. High Flow. Aluminum Bodies Air and Inert Gas 3/4" to 3" NPT.

4 qwer. Main Pulse Valves Dust Collector 2/2 SERIES H OME PAGE P RINT. High Flow. Aluminum Bodies Air and Inert Gas 3/4 to 3 NPT. 4 qwer High Flow Main Pulse Valves Aluminum Bodies Air and Inert Gas 3/4" to 3" NPT NC 2/2 SERIES Features Specially designed for reverse jet-type dust collector systems. High flow Cv s to 140 for effective

More information

Sizes 1/4" through 4" Medium Throttling Band

Sizes 1/4 through 4 Medium Throttling Band Sales Manual Section 160 PRODUCT SPECIFICATION RT-1003-D1,E1,F1 Self-Actuated Temperature Regulator RT-1003 Series FEATURES 1. Large two-ply, seamless Robertshaw bellows used for long life and extra power.

More information

Bourdon Tube Pressure Switches

Bourdon Tube Pressure Switches DA /DS Bourdon Tube es Visible setpoint, adjustable deadband, snap action switch pressure ranges to 000 psi Weather-Proof Types DAW, DSW, DRW -/1 2-1/1 REAR MOUNTING FLANGE ().20 DIA. HOLES AT 120 ON -1/2

More information

EH50 Product Manual Version

EH50 Product Manual Version EH50 Product Manual Version 2015.3 Last Updated: 3/2/15 J.Koba Product Description: The EH50 Series encompasses 2-way, pilot operated solenoid valves with a maximum allowable inlet pressure of 10,000 psi

More information

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT FEATURES Compact design, high fl ow rates Visual position indicator standard For temperatures from 22 F to +430 F / -30 C to 221 C Working pressures up

More information

2/2 ) % ) % ) Assemblies. Solenoid and Piloted Piston Valve Series Condensate Drain Valve Assemblies. Brass or Stainless Steel Bodies 1/4" to 1" NPT

2/2 ) % ) % ) Assemblies. Solenoid and Piloted Piston Valve Series Condensate Drain Valve Assemblies. Brass or Stainless Steel Bodies 1/4 to 1 NPT 4 Solenoid and Piloted Piston Series Condensate Drain Brass or Stainless Steel Bodies 1/4" to 1" NPT 2/2 Features Designed to automatically drain condensate in compressed air systems Piloted piston assemblies

More information

Condensed Catalog 410A January 2008

Condensed Catalog 410A January 2008 CATALOG Page 1 Condensed Catalog January 2008 This condensed catalog contains product specifically for R- applications. By including a minimum of engineering information we are able to provide a concise

More information

Table of Contents. Automatic Section A B V. Coil Piping Packages A B P P. Water Source Heat Pump Hose Kits A B H K

Table of Contents. Automatic Section A B V. Coil Piping Packages A B P P. Water Source Heat Pump Hose Kits A B H K Table of Contents Automatic Section Automatic Balance Valves Installation Operation Maintenance Instructions / Warranty Technical Information How To Order Coil Piping Packages Package Types How To Order

More information

Cash Valve B SERIES PRESSURE REGULATORS. ISSUED - JANUARY 1999 CAVMC-0509-US-0208 ISO 9001 Certified

Cash Valve B SERIES PRESSURE REGULATORS. ISSUED - JANUARY 1999 CAVMC-0509-US-0208 ISO 9001 Certified Cash Valve B SERIES REGULATORS ISSUED - JANUARY 1999 CAVMC-09-US-0208 ISO 9001 Certified GENERAL INFORMATION / REGULATORS B SERIES VALVES DESCRIPTION The Cash Valve Series B pressure reducing and regulating

More information

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation Deluge Valve DV-5 Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation GeneralDescription The Model DV-5 Deluge Valve (described in Technical

More information

/2. Hot Water and Steam Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT ^ % )

/2. Hot Water and Steam Valves Brass or Stainless Steel Bodies 1/8 to 2 1/2 NPT ^ % ) 888-87-6711 Normally Closed or Normally Open ot Water and Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT Features ot water service to 210 psi differential @ 210 F; sevice to 125 psi differential

More information

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series IRRIGATION Title Description Details Page Intro 3 2000 Series 4 Model 2000 Solenoid 1 3 12 Model 2000 Solenoid 4 8 15 Model 2030 Low Power Solenoid 1 3 17 Model 2030 Low Power Solenoid 4 8 19 Model 2160

More information

Index. Butterfly Valves

Index. Butterfly Valves Dry Bulk - Chemical - Petroleum Dry Bulk - Chemical - Petroleum Nozzles Nozzles & Valves & Index Index Part No. Description Page Nozzles P- 202 Overwing Aircraft Refueling, Bronze 1 P- 2022 Overwing Aircraft

More information

4 qwer. Steam and Hot Water Valves 2/2 SERIES. Hot Water/ Steam. Features. Construction. Nominal Ambient Temperature Ranges: Electrical.

4 qwer. Steam and Hot Water Valves 2/2 SERIES. Hot Water/ Steam. Features. Construction. Nominal Ambient Temperature Ranges: Electrical. qwer Normally Closed or Normally Open and Hot Water Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT NC NO 2/2 SERIES Features Handle the challenges of high-temperature fluids. PTFE and EPDM discs,

More information

Model 5000 Level Controller

Model 5000 Level Controller Features Multiple Configurations The 5000 level controller is easily configured for either reverse or direct actions for both pneumatic and electric pilot options. The pneumatic pilot is available in snap

More information

DE- OUT OUT DE- OUT OUT DE- SERIES MODEL E21 2-WAY NORMALLY OPEN CONDUIT HOUSG (700) 235 (0) 1 (3) (1) (700) 235 (0) 1 (3) (1) E21G7XC

DE- OUT OUT DE- OUT OUT DE- SERIES MODEL E21 2-WAY NORMALLY OPEN CONDUIT HOUSG (700) 235 (0) 1 (3) (1) (700) 235 (0) 1 (3) (1) E21G7XC SPECIFICATIONS 2-WAY 3-WAY EXPLOSION PROOF VALVES OPERATG CONDITIONS Media: Air, water, and other fluids, compatible with standard Buna seals. Hot water, steam, gasoline, and many oils require special

More information

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING SUNY GENESEO 220523-1 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

Airsweep Installation & Maintenance Manual. Airsweep Models VA-06 VA-12 VA-51 SECTION THREE SOLENOID VALVES

Airsweep Installation & Maintenance Manual. Airsweep Models VA-06 VA-12 VA-51 SECTION THREE SOLENOID VALVES Airsweep Installation & Maintenance Manual Airsweep Models VA-06 VA-12 VA-51 SECTION THREE SOLENOID VALVES Model DV1251 / Conduit & DIN Connection Model DV06 / RDV / MCA / RCA Diaphragm Valves Goyen Model

More information

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features TAC 1354 Clifford Avenue P.O. Box 2940 Loves Park, Illinois 61132-2940 www.invensysibs.com Two-Way and Three-Way Globe Valve Assemblies with 220 lbf Linear (979 N) Spring Return DuraDrive Actuators Submittal

More information

STYLE B THERMOSTATIC TEMPERATURE REGULATOR

STYLE B THERMOSTATIC TEMPERATURE REGULATOR STYLE B THERMOSTATIC TEMPERATURE REGULATOR MIL-V-19772A and MIL-DTL-19772B TYPE I (3-WAY) / TYPE II CLASS 1 / TYPE II CLASS 2 WITH MANUAL OVERRIDE and OVERHEAT PROTECTION SUITABLE FOR SHIPBOARD SERVICE

More information

Solenoid Valves Catalogue

Solenoid Valves Catalogue Solenoid Valves Catalogue lcon Solenoid Valve Range US Keeping the World Flowing Contents Section Page Section Page Introduction 3 U Series 4 U Series Exd 6 U3/U33 Series 8 U3/U33 Series Exd 0 68 Series

More information

Model BPS-09-Npt. Stainless Steel Back Pressure Bypass Valve

Model BPS-09-Npt. Stainless Steel Back Pressure Bypass Valve Phone (toll-free): (888) 380-9660 Phone (local): (973) 340-9955 Fax: (973) 340-9933 Web: www.straval.com 21 Columbus Avenue Garfield, NJ 07026 Model BPS-09-Npt Stainless Steel Back Pressure Bypass Valve

More information

Self-operated Temperature Regulators Type 1u Temperature Regulator

Self-operated Temperature Regulators Type 1u Temperature Regulator Self-operated Temperature Regulators Type 1u Temperature Regulator ANSI version Application Temperature regulators for cooling installations Control thermostats for set points 1) from 15 to 480 F ( 10

More information

Family of Products 1100 SERIES 1500 SERIES. 3 Piece Full Port Fire Safe Ball Valve ANSI Class WOG

Family of Products 1100 SERIES 1500 SERIES.   3 Piece Full Port Fire Safe Ball Valve ANSI Class WOG Family of Products 3210 S. Susan St, Santa Ana, CA 92704 Tel (714) 427-0877 Fax (714) 427-6392 www.avcovalve.com 1100 SERIES 3 Piece Full Port Fire Safe, PCTFE, PEEK, 1500 SERIES 3 Piece Full Port Fire

More information

DM2500 Series. Flanged Ball Valves SPECIFICATIONS ORDERING SCHEMATIC

DM2500 Series. Flanged Ball Valves SPECIFICATIONS ORDERING SCHEMATIC DM2500 Series Flanged Ball Valves SPECIFICATIONS Available in stainless steel or carbon steel Body and ends are investment cast Self-adjusting stem packing Blow-out proof stem design 100% air tested under

More information

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators I & M Mark (/ ) 0 Wasson Road Cincinnati, OH 0 USA Phone --00 Fax -8-00 info@richardsind.com www.jordanvalve.com Installation & Maintenance Instructions for Mark Pressure Regulators Warning: Jordan Valve

More information

Oil and Gas Products Pressures to 30,000 psi

Oil and Gas Products Pressures to 30,000 psi Oil and Gas Products MAXIMATOR has been designing and manufacturing specialty products to the high pressure market for over thirty years and has a worldwide reputation for quality and reliability. Oil

More information

Sinclair Collins. Process Control Valves. For Steam, Hot and Cold Liquids -40 to 450 F up to 500 psi. Catalog SCV-100/USA April 2001

Sinclair Collins. Process Control Valves. For Steam, Hot and Cold Liquids -40 to 450 F up to 500 psi. Catalog SCV-100/USA April 2001 Sinclair Collins Process Control Valves For Steam, Hot and Cold Liquids -40 to 450 F up to 500 psi April 2001 The Diaphragm Operated Valves on the following pages are designed for directing, diverting

More information

Operating Instructions. Valves Atkomatic Series ATEX and Series ATEX Series Series

Operating Instructions. Valves Atkomatic Series ATEX and Series ATEX Series Series Operating Instructions Valves Atkomatic 15800 Series ATEX and 30800 Series ATEX 15800 Series 30800 Series Atkomatic 15800 Series ATEX and 30800 Series ATEX Installation and Maintenance Instructions Revision

More information

SV80H Safety and Relief Valves

SV80H Safety and Relief Valves Page 1 of 18 BR Rev.02 U SH Safety and Relief alves Description The SH is a full nozzle safety and relief valve with orifices D to T, comply with the API STD 526, beyond others with super capacity. Suitable

More information

2/2 ^ % ) Normally Closed or Normally Open Hot Water and Steam Valves. Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT

2/2 ^ % ) Normally Closed or Normally Open Hot Water and Steam Valves. Brass or Stainless Steel Bodies 1/8 to 2 1/2 NPT Normally Closed or Normally Open Hot Water and Valves Brass or Stainless Steel Bodies 1/8" to 2 1/2" NPT 2/2 Features Handle the challenges of high-temperature fluids PTFE and EPDM discs, stainless steel

More information

Fire Protection Products LLC

Fire Protection Products LLC Fire Protection Products LLC LLC Over 60 years of FIRE PROTECTION CONTROL VALVES: When fire breaks out, water flow is paramount. OCV Control Valves offers a complete line of high performance listed and

More information

SECTION FACILITY FUEL OIL PIPING

SECTION FACILITY FUEL OIL PIPING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:

More information

Weksler Accessories STATIONARY RED SET HAND OVERLOAD STOP SPECIAL DIAL MAXIMUM POINTER VACUUM STOP

Weksler Accessories STATIONARY RED SET HAND OVERLOAD STOP SPECIAL DIAL MAXIMUM POINTER VACUUM STOP 33 Weksler Accessories THROTTLING DEVICES A throttling device should be used when a pressure gauge is subjected to rapid pressure fluctuations, which make the gauge difficult to read because of rapid pointer

More information

International Standard Valve, Inc. Trunnion Mounted Ball Valve

International Standard Valve, Inc. Trunnion Mounted Ball Valve International Standard Valve, Inc. TM ISV Series BT3E & BT3G-International Trunnion Mounted Ball Valve Forged Construction 2 through 56 ASME Class 150-2500 Bolted or Welded Body Flanged & Weld Ends API

More information

304C. Valve Group. Series Farris Engineering Pressure Relief Valves

304C. Valve Group. Series Farris Engineering Pressure Relief Valves 304C Valve Group Series 600 Farris Engineering Pressure Relief Valves Type Numbering System Our type numbering system simplifies the selection and specifying of Farris pressure relief valves because the

More information

PIPING PACKAGES TABLE OF CONTENTS

PIPING PACKAGES TABLE OF CONTENTS PIPING PACKAGES TABLE OF CONTENTS ITEM PAGE General Notes and Legend........................................................ 3 Piping Package Code Descriptions & Diagrams VAV Products and HL, HP, VF, and

More information

packless valves Packless Valves Index Bellows & Diaphragm

packless valves Packless Valves Index Bellows & Diaphragm Packless Valves Bellows & Diaphragm Index 0300 Series (Bellows) 1 4100 Series (Bellows) 4 4200 Series (Bellows) 8 4500 Series (Bellows) 11 4600 Series (Diaphragm) 13 DV1 Series (Diaphragm) 17 HOKE Inc.

More information

Hazardous Factory Sealed Control Devices

Hazardous Factory Sealed Control Devices Hazardous Factory Sealed Control Devices Description Page No. Application/Selection 428, 429 Dimensions 40 Manual Motor Starting Switches & Enclosures EDS Series 440, 44 Pilot Lights EFS Series 45 Pilot

More information

Solenoid Valves Magnetic Level Switches

Solenoid Valves Magnetic Level Switches Solenoid Valves agnetic Level Switches 3000 ODELS FOR ALL TYPES OF FLUIDS Approvals and Certificates Segurança N CC OCP 0034 UL Recognized Jefferson Solenoid Valves Association canadienne de normalisation

More information

Standard-Low Emission Valves to 100 PPM. A-Series Brass Appliance Valves CSA Approved; 1 & 2 piece Body Designs; Threaded & Flare End connections

Standard-Low Emission Valves to 100 PPM. A-Series Brass Appliance Valves CSA Approved; 1 & 2 piece Body Designs; Threaded & Flare End connections Standard-Low Emission Valves to 100 PPM Cast Steel Valves 150 2500 ASME; Gate, Globe & Check Valves; WCB & High Temperature Chrome Valves; Low Temperature Valves; Flanged, Butt-weld, RTG, End Connections;

More information

SECTION VALVES PART 1 -GENERAL

SECTION VALVES PART 1 -GENERAL SECTION 1571 0 VALVES PART 3- EXECUTION General Shut-off Valves Balancing Valves Drain Valves RELATED WORK Section 15430- Plumbing Specialties Section 15450- Plumbing Equipment PART 1 -GENERAL SCOPE This

More information

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment

E. Clark & Associates 10 Brent Drive Hudson, MA Tel. 978 / Fax 978 / Two Switch Output Hex Screw Adjustment CLARK SOLUTIONS 400 Series, Pressure, Vacuum, Diff. Pressure & Temp. Switches 1,2 & 3 Switch output, Adjustable Ranges 30 Vac to 6000 PSI, -180 to 650 o F DESCRIPTION The 400 Series is a versatile family

More information

CASH VALVES TYPE G-4 PRESSURE REGULATORS

CASH VALVES TYPE G-4 PRESSURE REGULATORS A self-actuating pilot operated pressure reducing valve handling air, gas and steam and accurate to within ½% up to 3" and 1% for sizes to 6 FEATURES Extremely compact design enables use of a smaller regulator.

More information

3-Way. Direct Acting & Pilot Operated Quick Exhaust Valves 1/4" - 3/8" NPT. General Description: Applications: Electrical Characteristics:

3-Way. Direct Acting & Pilot Operated Quick Exhaust Valves 1/4 - 3/8 NPT. General Description: Applications: Electrical Characteristics: Direct Acting & Pilot Operated Quick Exhaust Valves 1/4" - 3/8" General Description: Direct Acting & Pilot Operated Quick Exhaust Valves are designed to provide a large orifice for quick exhaust. Increased

More information

^ % P-SERIES Temperature Switches. Switches for -30 through 510 F with Adjustable Set Points and Fixed or Adjustable Deadband

^ % P-SERIES Temperature Switches. Switches for -30 through 510 F with Adjustable Set Points and Fixed or Adjustable Deadband P-SERIES Temperature Switches Switches for -30 through 5 F with Adjustable Set Points and Fixed or Adjustable Features: Set point repeatability, + F (/2 C). All wiring terminals, adjustments and visual

More information