Preinstallation Worksheet 3M Detection Systems Please complete this form and fax it to 3M at

Size: px
Start display at page:

Download "Preinstallation Worksheet 3M Detection Systems Please complete this form and fax it to 3M at"

Transcription

1 Preinstallation Worksheet 3M Detection Systems Please complete this form and fax it to 3M at Today s date Sales consultant Account name Key contact name Phone No. Installation location Install contact name Phone No. Installation date Purchasing/payment contact Phone No. Select a mounting option: Direct Mount Base Plate Buried Cable 2300/3500/3800/ /3500/3800/ /3500/3800/8800 Minimum distance to protected books: 3 ft. [914 mm] System model number(s) Accessories Delayed warranty start date (if applicable) Model/serial number of equipment to be replaced/removed 3M dismantle at additional current rates... Customer dismantle and removal... Preinstallation worksheet reviewer Note: It is the customer s responsibility to move the system within 10 ft. of the installation location before scheduling the installation. Does account require PO number for payment of invoices? Yes No Minimum distance to steel-stud wall: 2300/ ft. [914 mm] in. [457 mm] in. [76,2 mm] Minimum distance to door frame 4 ft. [1,22 m] to comply with ADA Minimum distance to large metal objects: 2300/ ft. [914 mm] in. [457 mm] in. [15,24 cm] Your site layout must meet the following requirements to help ensure optimal performance: Minimum distance from system to large metal objects (windows, doors, walls, display cases, shelves, cabinets, picture frames, counter edges, waste baskets, and furniture): 2300/ ft. [91,4 cm] in. [45,7 cm] in. [15,24 cm] Minimum distance from system to CRT: 3500/ ft. [2,13 m] ft. [91,4 cm] in. [7,6 cm] The electronics enclosure for the Model 3500 must be a minimum of 4 ft. [1,22 m] from system panels, and within 10 ft. [3,05 m] of power source. The system must be at least 5 ft. [1,52 m] from copiers (3 in. [76,2 mm] for the Model 8800). The system must be at least 3 ft. [914 mm] from materials containing security markers. The system must be at least 4 ft. [1,22 m] from door frames to meet ADA requirements. The system must be within 10 ft.* [3,05 m] of the power source (9.84 ft.* 3,0 m for Model 8800). * Wire-run distance, not straight-line distance inch ID non-metallic conduit for buried-cable systems (1.5-inch ID non-metallic conduit for the Model 2300). See the Architect/Contractor Information Package for system dimensions and requirements. 3M Library Systems 3M Center, Bldg N-14 St. Paul, Minnesota Minimum distance to computer: 3500/ ft. [2,13 m] ft. [914 mm] in. [76,2 mm] Maximum distance to power outlet: 2300/3500/ ft. [3,05m] ft. [3,0 m] 1 square = 1 ft. (30.5 cm) Minimum distance to copy machine 5 ft. [1,52 m] (2300/3500/3800 only) Note: The concrete thickness under the mounting feet must be a minimum of 3.5 in. [89 mm]. Draw your system layout in the following grid: Doors Printed in U.S.A. Copyright M. All rights reserved , 060-A, Rev. E-1

2 The eleven most important points for the successful installation of 3M Detection Systems 1 Maintain the proper distance between the Detection System and large metal objects. The minimum distances from a Detection System Panel to a wall using metal studs and metal windows, doors, walls, cabinets, shelves, pipes, counter edges, display cases, wastebaskets, and furniture are: Model in. [457 mm] Model 2300 and Model ft. [914 mm] 2 Locate the Detection System within the maximum distance to a power receptacle: (These distances are measured in wire-run feet, not straight-line distance.) The Model 2300 and Model 3800 power inlet can be a maximum of 10 ft. [3,05 m] from a power receptacle. The Model 3500 electronic enclosure must be mounted within 10 ft. [3,05 m] of a power receptacle and a minimum of 4 ft. [1,2 m] from the detection panels. 3 For buried-cable installations, use the following non-metallic conduit with correct spacing. (Correctly sized conduit is needed to accommodate connectors on the ends of the cables.) Model 2300 and Model 3500 use 1.5-inch [38-mm], non-metallic conduit Model 3800 use 1.25-inch [31,8-mm], non-metallic conduit 4 Locate the Detection System at least 5 ft. [1,52 m] from copier machines. 5 Maintain the minimum distance from the Detection System to a CRT display: Model ft. [9,14 cm] Model ft. [2,44 m] Model ft. [2,13 m] 6 Avoid positioning the Detection System near power panels, data cables, and large conduits. Model ft. [1,52 m] minimum between the Detection System and power/data conduit. Model 2300/Model ft. [3,05 m] minimum between the Detection System and power/data conduit. 7 Provide a 4-foot [1,22 m] clear space between the Model system panels and any door. Required for ADA (Americans with Disabilities Act) compliance. 8 Plan the system layout so that patrons entering and exiting the library do not interfere with each other. Avoid two-way traffic in a single corridor. 9 Plan the system layout so that the corridor(s) are centered on the door(s). 10 Locate the system to allow good observation/supervision of the system by your circulation-desk staff. 11 Locate the system so that books and other secured items are stored at least 3 feet [914 mm] from the Detection System. (This helps ensure that secured items within the library are not detected by the system.) Books and other secured items must be stored at least 3 feet [914 mm] from the Detection System. Patrons and book carts with secured items cannot pass within 3 feet [914 mm] of the Detection System. 1-1

3 System Design Considerations 3M Detection Systems The following design considerations should be addressed when planning the layout of any 3M Detection System. Patron traffic patterns 1 Does your system layout plan center the corridor(s) on the door(s) and help establish normal traffic patterns? 2 Do patrons have an easy exit path? Keep changes in traffic direction between check-out and exit to an absolute minimum. 3 Will patrons entering and exiting the library interfere with each other? Avoid two-way traffic in a single corridor. 4 In the event of an alarm, is there room to identify or stop patrons before they leave the library? 5 Are there enough detection-system corridors available to handle typical amount of traffic and to meet codes? 6 While in the library, will patrons stand directly next to the system or carry secured items within three feet of the system? This may cause false alarms. 7 Will your book carts fit through the corridor? System location 1 Have you attempted to position the system so it can be moved as much as one foot in any direction (if necessary) to compensate for minor environmental interference? 2 Do check-out personnel have good visibility and access to the detection hardware? 3 Are all applicable codes met? 4 Have you investigated whether there are large metal objects hidden within or behind the walls? 5 Is power located to minimize the need to run cords and wire molding through traffic areas? 6 Will book carts with secured items be stored near the detection system? To avoid false alarms, all secured items must be kept at least 3 ft. from the detection system at all times. 7 Have you considered future placement of CRTs and other electronic devices that may cause system interference? 1-2

4 Architects/Contractors Information Package This package provides architects and contractors with all the information necessary to promote successful equipment installation and optimum operating environment for your new 3M Library Detection System. Nearly 30 years of experience in helping libraries protect books and related media from unauthorized removal has provided the basis for this information. The components of this package provide precise dimensional and environmental information to assure optimum performance. This package is divided into two sections: 1. General Information Letter to Architect/Contractor Most Important Points for a Successful Installation 1-2 Preinstallation Worksheet 1-3 Design and Layout Considerations 1-4 Page 2. 3M Model 2300 Series Product Information Product brochure Model 2301/2302 System Layout Checklist 2-1 (contains environmental requirements) Models 2301 and 2302 Installation Specifications 2-3 thru 2-16 (choose the configuration that meets your needs) Contractor Installation Instructions for 3M Model 2301/ Buried Power Contractor Installation Instructions and Layout Plans for 2-18 thru M Models 2301/2302 with Buried Cables We hope this package will address all of your needs. Should you require any additional information or pricing, please call , option #3 to leave a message for the 3M Sales Consultant in your area. 3M Library Systems 3M Center, Bldg N-14 St. Paul, MN Rev. E

5 3M Model 2300 Series System Layout Checklist This checklist contains the information necessary to provide the environment required to successfully install your new Model 2300 system. 4 1/2 in. [114 mm] 36 in. [914 mm] Alarm Light Alarm Light Patron Counter/ Diagnostic Display 67 1/2 in. [1,71 m] 67 1/2 in. [1,71 m] Power Cord 38 in. [965 mm] Model 2301 with Baseplate Model 2302 Direct Mount C Power Requirements 3M Detection Systems are sophisticated computer based devices which require high quality surge and noise free electrical power for optimum performance. Energy Profile 1. Single phase power is required. 2. Designed for worldwide use with internal (manual) switch selection for voltage from 100 to 240 VAC, 50 or 60 Hz. 3. Maximum RMS current draw: a. 100/120 VAC: 0.8A b. 210/240 VAC: 0.4A 4. Power cord: the Model 2300 is supplied with a 16 ga., 3-wire, S-rating, 14-foot [4,26 m] long, NEMA 5-15P plug type power cord. The customer must supply an electrical outlet within the power cord length. Power cannot be supplied from under the detection system. It must be off to the side of the lattice. 5. A dedicated circuit is not required but is recommended to prevent overloading and loss of security. 6. A minimum circuit capacity of 15A is recommended. 7. Circuit loading must not exceed 50% of the rated circuit current to ensure voltage stability System Placement Relative to Interfering Objects The system must be placed in an environment free of certain types of electrical interference. Check the following list of items to verify your system will be located an adequate distance from sources of electrical interference. Computers (CRT) For optimum performance, computer terminals should be placed at least 3 feet [914 mm] from the closest lattice. Multiple computers will generally require a greater distance from the Increase the distance for each additional computer by 1.5 feet [457 mm]. For example, if there are 5 computers within 10 feet [3 m]; the minimum distance for each computer is as follows: Computer #1: 3 feet [914 mm] Computer #2: 4.5 feet [1,37 m] Computer #3: 6 feet [1,82 m] Computer #4: 7.5 feet [2,26 m] Computer #5: 9 feet [2,74 m] Computers that are more than 10 feet [3 m] away from the 2300 should not be a problem. Copy Machines Copy machines are not allowed within 5 feet [1,5 m] of the closest lattice. 2-1

6 Energy Management Large Metal Objects (LMO) Metal Framed Doors, Windows and Counters Protected Material Heating, ventilation and Air Conditioning Energy Management Systems may generate high levels of electronic noise which can reduce the performance level of the Model Please contact EAS Technical Service for more information. Large metal objects are not allowed within 2 feet [609 mm] of a lattice. Examples include: refrigerators, heavy support beams, heating/air conditioning duct work. ADA (Americans with Disabilities Act) requires a 4-foot [1,2 m] clear space at exit doors for wheelchair maneuvering space. This is the recommended system placement. The closest lattice of the Model 2300 system should be located at least 3 feet [914 mm] from a metal door frame. Books and other protected articles should be at least 3 feet [914 mm] from the closest point of the security system. Plan layout so that patrons will not congregate or wait in line within 3 feet [914 mm] of a lattice. Walls (Steel Studs) Walls with steel studs are not allowed within 3 feet [914 mm] of the closest lattice. We recommend the use of wood 2 x 4s for wall studs within 3 feet [914 mm] of the system. System Accessories Alarm/Disable Box Distance Between Systems Exit Control Hardware The optional alarm/disable box is wired to the lattice base. Our standard installation includes 27 feet [8,3 m] of ¼-inch [6 mm] diameter wire. Additional wire length can be purchased at an upcharge for time and material. Use wire mold or ½-inch [13 mm] diameter conduit to protect the wiring. The minimum distance between two Model 2300 systems is 12 inches [304 mm]. The minimum distance to a Model 1365, 1370, or 1850 system is 12 inches [304 mm]. More than two Model 1365, 1370, 1850, or 2300 systems require 18 inches [456 mm] between them. The minimum distance to a Model 3800 system is 30 feet [9,14 m]. The minimum distance to a Model 3500 system is 20 feet (6.0 m). All metal exit control hardware must be located a minimum of 12 inches [304 mm] from each lattice. If a metal rail is placed parallel to the lattice, it must be placed at least 2 feet [609 mm] away from the lattice. Metal railings surrounding the system using two or more horizontal members must be a minimum of 3 feet [914 mm] from each lattice. Alvarado, Accent, and Lawrence are approved vendors for exit control hardware. 2-2

7 3M Model 2301 Detection System with Baseplate Installation Specifications System Information The Model 2301 is a single corridor detection system consisting of two panels that are mounted to a baseplate. The electronics are enclosed in the system pedestals. The corridor width is 36 inches [914 mm] to comply with ADA (Americans with Disabilities Act). An alarm light is located on top of one panel and an audible alarm is located in the pedestal. An LCD Patron/Alarm Counter and Diagnostic Display are mounted on the panel for ease of viewing. Power wiring can be routed on the surface in UL listed wire mold or buried under the finished floor in an approved conduit. Other important product and installation facts are: 1. System can be rotated 180 to reverse the power entry and counter location. 2. System to be located on level surface. 3. System packaged weight is 272 pounds [122 kg]. 4. System Color - Gray 3U. 5. Carpet color is charcoal gray. 6. System is available in 36 inch corridor width. 7. System installation location must comply with the Model 2300 System Layout Checklist to 2-3 avoid performance problems. 8. The system is shipped with provisions for anchoring the baseplate to the floor. 9. The minimum distance between two 2300 systems is 12 inches [304 mm]. 10. The minimum distance between three or more 2300 systems is 18 inches [456 mm].

8 Power Requirements 3M Model 2301 is a computer-based device which requires high quality, surge free, and noise free electrical power for optimum performance. Energy Profile 1. Single phase electrical power is required. 2. System operates on a standard 110/120 VAC, 60 Hz within the U.S. 3. Designed for worldwide use with internal (manual) switch selection for voltages from 100 to 240 VAC, 50 or 60 Hz. 4. Maximum RMS current draw: a. 100/120 VAC -.8 Amps b. 210/240 VAC -.4 Amps 5. Power Cord: 2301 is supplied with a 16 ga. 3-wire, S-rating, 14 feet [4,26 m] long, NEMA 5-15P plug type. 6. Electrical power can be supplied from a wall or floor mounted receptacle. 7. Customer must supply an electrical outlet within the power cord length. A dedicated circuit is not required but is recommended to prevent overloading and loss of security. A minimum circuit capacity of 15 Amps is required. Circuit loading must not exceed 50% of the rated current to ensure voltage stability. Note In all system configurations, avoid running power on the surface across traffic areas. In all cases the power cord must be protected in a covered metal raceway which is anchored to the flooring. Do not run power cords under or through the system baseplate. All conduit, outlet boxes, and covers must be installed in compliance with the National Electrical Code and/or local codes. Options: Remote alarm/disable switch CCTV monitor Auxiliary relay contacts Voice alarm General Notes 1. See System Layout Checklist for System Placement Relative to Interfering Objects. 2. The system is shipped with provisions for anchoring the baseplate to the floor. 3. Remote alarm/disable switch (optional) wiring must enter the system through the pedestal/panel containing the patron counter. Entry points are through the back or ends of the pedestal. Power Wiring Requirements Surface Wiring Power cord enclosed in 2600 series wire mold, enter system through back or ends of the system pedestal. No customer construction required. Under Floor Wiring Floor mounted electrical box placed directly along side the system baseplate. Power cord is connected to the electrical box by plug and receptacle, or by hardwiring the power cord into the box through a sealed fitting. See Contractors Instructions for Buried Power. 2-4

9 Power Cord 14 ft. [4,26 m] Optional Remote Alarm/ Disable Switch (Cable length 27 ft. [8,3 m]) Route through Wire Mold Surface Mount Wire Mold # C IMPORTANT NOTICE: THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTY OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 3M warrants that the Model 2301 will be free of defects in material and manufacture for a period of 90 days from the date of installation by 3M. Provided the system has been properly installed, operated and maintained by purchaser, 3M will, at 3M s option, repair, replace or refund the purchase price of such quantity of product determined to be defective. This warranty shall not apply to any system or component which has been repaired or modified by persons not authorized by 3M so that, in 3M s judgement, the performance or reliability is adversely affected thereby, or which is subjected to accident, misuse or neglect. Except as provided above, 3M shall not be liable or responsible for any loss or damage, whether direct, indirect, or consequential, arising out of the sale, use or misuse of 3M Library Systems products, or the user s inability to use such products. THE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE. Statements or recommendations not contained herein shall have no force of effect unless in an agreement signed by an authorized representative of 3M. 3M reserves the right to make any changes in the design or construction of its products without obligation in respect to products previously sold and delivered. For further information or assistance, please contact 3M Library Systems, 800/

10 3M Model 2302 Detection System with Baseplate Installation Specifications System Information The Model 2302 is a dual corridor detection system consisting of three panels that are mounted to a baseplate. The electronics are enclosed in the system pedestals. The corridor width is 36 inches [914 mm] to comply with ADA (Americans with Disabilities Act.) An alarm light is located on top of each outer panel and an audible alarm is located in the pedestal. An LCD Patron/Alarm Counter and Diagnostic Display are mounted on the panel for ease of viewing. Power wiring can be routed on the surface in UL listed wire mold or buried under the finished floor in an approved conduit. Other important product and installation facts are: 1. System can be rotated 180 to reverse the power entry and counter location. 2. System to be located on level surface. 3. System packaged weight is 410 pounds [185 kg]. 4. System Color - Gray 3U. 5. Carpet color is charcoal gray. 6. System is available in 36 inch corridor width. 7. System installation location must comply with the Model 2300 System Layout Checklist to avoid performance problems. 8. The system is shipped with provisions for anchoring the baseplate to the floor. 9. The minimum distance between two 2300 systems is 12 inches [304 mm]. 10. The minimum distance between three or more 2300 systems is 18 inches [456 mm]. 2-6

11 Power Requirements 3M Model 2302 is a computer-based device, which requires high quality, surge free, and noise free electrical power for optimum performance. Energy Profile 1. Single phase electrical power is required. 2. System operates on standard 110/120 VAC, 60 Hz within the U.S. 3. Designed for worldwide use with internal (manual) switch selection for voltages from 100 to 240 VAC, 50 or 60 Hz. 4. Maximum RMS current draw: 5. Power Cord: 2302 is supplied with a 16 ga. 3-wire, S-rating, 14 feet [4,26 m] long, NEMA 5-15P plug type. a. 100/120 VAC -.8 Amps b. 210/240 VAC -.4 Amps 6. Electrical power can be supplied from a wall or floor mounted receptacle. 7. Customer must supply an electrical outlet within the power cord length. A dedicated circuit is not required but is recommended to prevent overloading and loss of security. A minimum circuit capacity of 15 Amps is required. Circuit loading must not exceed 50% of the rated current to ensure voltage stability. Note In all system configurations, avoid running power on the surface across traffic areas. In all cases the power cord must be protected in a covered metal raceway which is anchored to the flooring. Do not run power cords under or through the system baseplate. All conduit, outlet boxes, and covers must be installed in compliance with the National Electrical Code and/or local codes. Options: Remote alarm/disable switch CCTV monitor Auxiliary relay contacts Voice Alarm General Notes 1. See System Layout Checklist for System Placement Relative to Interfering Objects. 2. The system is shipped with provisions for anchoring the baseplate to the floor. 3. Remote alarm/disable switch (optional) wiring must enter the system through the pedestal/panel containing the patron counter. Entry points are through the back or ends of the pedestal. Power Wiring Requirements Surface Wiring Power cord enclosed in 2600 series wire mold, enter system through back or ends of the system pedestal. No customer construction required. Under Floor Wiring Floor mounted electrical box placed directly along side the system. Power cord is connected to the electrical box by plug and receptacle, or by hardwiring the power cord into the box through a sealed fitting. See Contractors Instructions for Buried Power. 2-7

12 Power Cord 14 ft. [4,26 m] Optional Remote Alarm/ Disable Switch (Cable length 27 ft. [8,3 m]) Route through Wire Mold Surface Mount Wire Mold # C IMPORTANT NOTICE: THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTY OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 3M warrants that the Model 2302 will be free of defects in material and manufacture for a period of 90 days from the date of installation by 3M. Provided the system has been properly installed, operated and maintained by purchaser, 3M will, at 3M s option, repair, replace or refund the purchase price of such quantity of product determined to be defective. This warranty shall not apply to any system or component which has been repaired or modified by persons not authorized by 3M so that, in 3M s judgement, the performance or reliability is adversely affected thereby, or which is subjected to accident, misuse or neglect. Except as provided above, 3M shall not be liable or responsible for any loss or damage, whether direct, indirect, or consequential, arising out of the sale, use or misuse of 3M Library Systems products, or the user s inability to use such products. THE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE. Statements or recommendations not contained herein shall have no force of effect unless in an agreement signed by an authorized representative of 3M. 3M reserves the right to make any changes in the design or construction of its products without obligation in respect to products previously sold and delivered. For further information or assistance, please contact 3M Library Systems, 800/

13 3M Model 2301 Detection System Direct Mount/Buried Cable or Direct Mount/Threshold Installation Specifications Buried Cable 1 1/4 in. [31 mm] Main Power 2 1/2 in. [63 mm] 2 1/2 in. [63 mm] Alarm Light 4 1/2 in. [114 mm] 36 in. [914 mm] 18 in. [457 mm] Max. Depth 4 1/2 in. [114 mm] System Front View 67 1/2 in. [1713 mm] 7/8 in. [22 mm] 38 in. [965 mm] 35 in. [889 mm] 21 in. [533 mm] System Side View 11 3/4 in. [298 mm] Main Power 19 in. [482 mm] 4 in. [101 mm] 45 in. [1143 mm] System Top View 2300_266a 38 in. [965 mm] Installation Specifications Threshold 1 1/4 in. [31 mm] Main Power 2 1/2 in. [63 mm] Alarm Light 4 1/2 in. [114 mm] 36 in. [914 mm] 67 1/2 in. [1713 mm] 7/8 in. [22 mm] 38 in. [965 mm] 35 in. [889 mm] 11 3/4 in. [298 mm] Main Power 19 in. [482 mm] 4 in. [101 mm] 8.3 in. [210 mm] 45 in. [1143 mm] 38 in. [965 mm 2 1/2 in. [63 mm] 1/2 in. [12 mm] Threshold 4 1/2 in. [114 mm] 21 in. [533 mm] System Side View System Top View System Front View 2300_267a 2-9

14 System Information The Model 2301 is a single corridor detection system consisting of two panels that are mounted to the floor using a mounting foot. The electronics are enclosed in the system pedestals. The corridor width is 36 inches [914 mm] to comply with ADA (Americans with Disabilities Act). An alarm light is located on top of one panel and an audible alarm is located in the pedestal. An LCD Patron/Alarm Counter and Diagnostic Display are mounted on the panel for ease of viewing. Power wiring can be routed on the surface in UL listed wire mold or buried under the finished floor in an approved conduit. Other important product and installation facts are: 1. System can be rotated 180 to reverse the power entry and counter location. 2. System to be located on level surface. 3. System packaged weight is 272 pounds [122 kg]. 4. System Color - Gray 3U. 5. System is available in 36 inch corridor width. 6. System installation location must comply with the Model 2300 System Layout Checklist to avoid performance problems. 7. The system is shipped with provisions for anchoring directly to the floor. 8. The minimum distance between two 2300 systems is 12 inches [304 mm]. 9. The minimum distance between three or more 2300 systems is 18 inches [456 mm]. 10. System is anchored to the floor using 3/8 x 3-inch concrete anchors. Direct Mount with Buried Cable System panel-to-panel wires are run below the finished floor in PVC conduit. Conduit installation is the responsibility of the customer. Direct Mount With Threshold Panel-to-panel wiring is enclosed in an 8.3 inch [210 mm] wide anodized aluminum threshold. Power Requirements 3M Model 2301 is a computer-based device, which requires high quality, surge free, and noise free electrical power for optimum performance. Energy Profile 1. Single phase electrical power is required. 2. Designed for worldwide use with internal (manual) switch selection for voltages from 100 to 240 VAC, 50 or 60 Hz. 3. Maximum RMS current draw: a. 100/120 VAC -.8 Amps b. 210/240 VAC -.4 Amps 4. Power Cord: 2301 is supplied with a 16 ga. 3-wire, S-rating, 14 feet [4,26 m] long, NEMA 5-15P plug type. 5. Electrical power can be supplied from a wall or floor mounted receptacle. 6. Customer must supply an electrical outlet within the power cord length. A dedicated circuit is not required but is recommended to prevent overloading and loss of security. A minimum circuit capacity of 15 Amps is required. Circuit loading must not exceed 50% of the rated current to ensure voltage stability. Power Wiring Requirements Surface Wiring Power cord enclosed in 2600 series wire mold, enter system through back or ends of the system pedestal. No customer construction required. Under Floor Wiring Floor mounted electrical box placed directly along side the system. Power cord is connected to the electrical box by plug and receptacle, or by hardwiring the power cord into the box through a sealed fitting. See Contractors Instructions for Buried Power. Note In all system configurations, avoid running power on the surface across traffic areas. In 2-10

15 all cases the power cord must be protected in a covered metal raceway which is anchored to the flooring. All conduit, outlet boxes, and covers must be installed in compliance with the National Electrical Code and/or local codes. Panel-to-Panel Wiring Direct Mount 1. Enclosed in threshold by 3M. Panel-to-Panel Wiring Buried Cable 1. Below finished flooring. (Wiring enclosed in 1.5 inch [38 mm] I.D. PVC, electrical conduit. Conduit installed by customer. See Model 2301 Contractor Layout Plan - Buried Wiring and Power. ) Options: Remote alarm/disable switch CCTV monitor Auxiliary relay contacts Voice Alarm General Notes 1. See System Layout Checklist for System Placement Relative to Interfering Objects. 2. Remote switch (optional) wiring must enter the system through the pedestal/panel containing the patron counter. Entry points are through the back or ends of the pedestal. 2. Panel-to-panel cables are long enough for conduit that is placed a maximum of 18 inches [457 mm] below the finished floor surface. PVC conduit should extend 1/4-1/2 inch [6-12 mm] above the finished floor. 3. Conduit placement is critical as it defines where the system will be located. System location must comply with all requirements of the 3M Model 2300 System Layout Checklist. 2-11

16 Power Cord 14 ft. [4,26 m] Optional Remote Alarm/ Disable Switch (Cable length 27 ft. [8,3 m]) Threshold Route through Wire Mold Surface Mount Wire Mold #2600 or Buried Power/Receptacle C IMPORTANT NOTICE: THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTY OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 3M warrants that the Model 2301 will be free of defects in material and manufacture for a period of 90 days from the date of installation by 3M. Provided the system has been properly installed, operated and maintained by purchaser, 3M will, at 3M s option, repair, replace or refund the purchase price of such quantity of product determined to be defective. This warranty shall not apply to any system or component which has been repaired or modified by persons not authorized by 3M so that, in 3M s judgement, the performance or reliability is adversely affected thereby, or which is subjected to accident, misuse or neglect. Except as provided above, 3M shall not be liable or responsible for any loss or damage, whether direct, indirect, or consequential, arising out of the sale, use or misuse of 3M Library Systems products, or the user s inability to use such products. THE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE. Statements or recommendations not contained herein shall have no force of effect unless in an agreement signed by an authorized representative of 3M. 3M reserves the right to make any changes in the design or construction of its products without obligation in respect to products previously sold and delivered. For further information or assistance, please contact 3M Library Systems, 800/

17 3M Model 2302 Detection System Direct Mount/Buried Cable or Direct Mount/Threshold 1 1/4 in. [31 mm] 2 1/2 in. [63 mm] Installation Specifications Buried Cable Alarm Light 4 1/2 in. [114 mm] Alarm Light 38 in. [965 mm] 35 in. [889 mm] 36 in. [914 mm] 36 in. [914 mm] 67 1/2 in. [1713 mm] Main Power 4 1/2 in. [114 mm] 7/8 in. [22 mm] 11 3/4 in. [298 mm] 2 1/2 in. [63 mm] 18 in. [457 mm] Max. Depth System Front View 21 in. [533 mm] System Side View Main Power 19 in. [482 mm] 4 in. [101 mm] 38 in. [965 mm] 85 1/2 in. [2173 mm] System Top View 2300_264a 1 1/4 in. [31 mm] 2 1/2 in. [63 mm] Installation Specifications Threshold Alarm Light Alarm Light 38 in. [965 mm] 35 in. [889 mm] 36 in. [914 mm] 36 in. [914 mm] 67 1/2 in. [1713 mm] Main Power 7/8 in. [22 mm] 11 3/4 in. [298 mm] 2 1/2 in. [63 mm] 1/2 in. [12 mm] Threshold 4 1/2 in. [114 mm] System Front View 21 in. [533 mm] System Side View Main Power 4 in. [101 mm] 38 in. [965 mm] 19 in. [482 mm] 8.3 in. [210 mm] 2300_265a 85 1/2 in. [2173 mm] System Top View 2-13

18 System Information The Model 2302 is a dual corridor detection system consisting of three panels that are mounted to the floor using a mounting foot. The electronics are enclosed in the system pedestals. The corridor width is 36 inches [914 mm] to comply with ADA (Americans with Disabilities Act.) An alarm light is located on top of each outer panel and an audible alarm is located in the pedestal. An LCD Patron/Alarm Counter and Diagnostic Display are mounted on the panel for ease of viewing. Power wiring can be routed on the surface in UL listed wire mold or buried under the finished floor in an approved conduit. Other important product and installation facts are: 1. System can be rotated 180 to reverse the power entry and counter location. 2. System to be located on level surface. 3. System packaged weight is 410 pounds [185 kg]. 4. System Color - Gray 3U. 5. System is available in 36 inch corridor width. 6. System installation location must comply with the Model 2300 System Layout Checklist to avoid performance problems. 7. The system is shipped with provisions for anchoring directly to the floor. 8. The minimum distance between two 2300 systems is 12 inches [304 mm]. 9. The minimum distance between three or more 2300 systems is 18 inches [456 mm]. 10. System is anchored to the floor using 3/8 x 3-inch concrete anchors. Direct Mount with Buried Cable System panel-to-panel wires are run below the finished floor in PVC conduit. Conduit installation is the responsibility of the customer. Direct Mount With Threshold Panel-to-panel wiring is enclosed in an 8.3 inch [210 mm] wide anodized aluminum threshold. Power Requirements 3M Model 2302 is a computer-based device, which requires high quality, surge free, and noise free electrical power for optimum performance. Energy Profile 1. Single phase electrical power is required. 2. Designed for worldwide use with internal (manual) switch selection for voltages from 100 to 240 VAC, 50 or 60 Hz. 3. Maximum RMS current draw: a. 100/120 VAC -.8 Amps b. 210/240 VAC -.4 Amps 4. Power Cord: 2302 is supplied with a 16 ga. 3-wire, S-rating, 14 feet [4,26 m] long, NEMA 5-15P plug type. 5. Electrical power can be supplied from a wall or floor mounted receptacle. 6. Customer must supply an electrical outlet within the power cord length. A dedicated circuit is not required but is recommended to prevent overloading and loss of security. A minimum circuit capacity of 15 Amps is required. Circuit loading must not exceed 50% of the rated current to ensure voltage stability. Power Wiring Requirements Surface Wiring Power cord enclosed in 2600 series wire mold, enter system through back or ends of the system pedestal. No customer construction required. Under Floor Wiring Floor mounted electrical box placed directly along side the system. Power cord is connected to the electrical box by plug and receptacle, or by hardwiring the power cord into the box through a sealed fitting. See Contractors Instructions for Buried Power. 2-14

19 Note In all system configurations, avoid running power on the surface across traffic areas. In all cases the power cord must be protected in a covered metal raceway which is anchored to the flooring. All conduit, outlet boxes, and covers must be installed in compliance with the National Electrical Code and/or local codes. Panel-to-Panel Wiring Direct Mount 2. Enclosed in threshold by 3M. Panel-to-Panel Wiring Buried Cable 1. Below finished flooring. (Wiring enclosed in 1.5 inch [38 mm] I.D. PVC, electrical conduit. Conduit installed by customer. See Model 2301 Contractor Layout Plan - Buried Wiring and Power. ) Options: Remote alarm/disable switch CCTV monitor Auxiliary relay contacts Voice Alarm General Notes 1. See System Layout Checklist for System Placement Relative to Interfering Objects. 2. Remote switch (optional) wiring must enter the system through the pedestal/panel containing the patron counter. Entry points are through the back or ends of the pedestal. 2. Panel-to-panel cables are long enough for conduit that is placed a maximum of 18 inches [457 mm] below the finished floor surface. PVC conduit should extend 1/4-1/2 inch [6-12 mm] above the finished floor. 3. Conduit placement is critical as it defines where the system will be located. System location must comply with all requirements of the 3M Model 2300 System Layout Checklist. 2-15

20 Power Cord 14 ft. [4,26 m] Optional Remote Alarm/ Disable Switch (Cable length 27 ft. [8,3 m]) Threshold Route through Wire Mold Surface Mount Wire Mold #2600 or Buried Power/Receptacle C IMPORTANT NOTICE: THE FOLLOWING IS MADE IN LIEU OF ALL WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, INCLUDING THE IMPLIED WARRANTY OR CONDITIONS OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 3M warrants that the Model 2302 will be free of defects in material and manufacture for a period of 90 days from the date of installation by 3M. Provided the system has been properly installed, operated and maintained by purchaser, 3M will, at 3M s option, repair, replace or refund the purchase price of such quantity of product determined to be defective. This warranty shall not apply to any system or component which has been repaired or modified by persons not authorized by 3M so that, in 3M s judgement, the performance or reliability is adversely affected thereby, or which is subjected to accident, misuse or neglect. Except as provided above, 3M shall not be liable or responsible for any loss or damage, whether direct, indirect, or consequential, arising out of the sale, use or misuse of 3M Library Systems products, or the user s inability to use such products. THE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE. Statements or recommendations not contained herein shall have no force of effect unless in an agreement signed by an authorized representative of 3M. 3M reserves the right to make any changes in the design or construction of its products without obligation in respect to products previously sold and delivered. For further information or assistance, please contact 3M Library Systems, 800/

21 Contractor Installation Instructions for 3M Model 2301/2302 Buried Power Note Read all installation instructions before starting procedures. If there are any questions, call 3M Technical Service option #6. Materials Required Item Supplier 1. Steel floor box, conduit, and associated wiring Electrical Contractor 2. Floor box cover plate, gasket, and carpet ring if needed Electrical Contractor 3. AC power cord (part of Model 2301/2302 System) 3M 4. Device to cut trench in floor Contractor 5. Material to fill in around and cover conduit after trench is cut Contractor Installation Procedure 1. Install a steel floor box. Position box per Model 2301/2302 Contractor Layout Plan and the figure below. Floor box is typically 5 inches x 5 inches [127 x 127 mm], with a 4 inch [101 mm] cover flange. Some variations from the different suppliers utilize boxes with pre-pour and after-pour level adjustments. If necessary, request assistance from a 3M Service Technician in positioning floor box. The floor box cannot be located under the detection system. It must be off to the side of the lattice. 2. Complete wiring from floor box to Amp circuit, preferably dedicated for the security system. 3. At system install, terminate system power cord to circuit wires, install gasket, cover plate, and carpet ring if required. Allow an extra 2 feet [609 mm] of power cord to be stored in the Model 2300 pedestal. 4. The 3M Service Technician will energize and check out the system. 2-17

22 Contractor Installation Instructions for 3M Model 2301 with Buried Cables (36 in., Corridor) Note Read all installation instructions before starting this installation procedure. If there are any questions, contact 3M Library Systems, Technical Service, , option #6. If AC power wiring is also buried, see Contractor Installation Instructions for 3M Model 2301/2302, Buried Power. Materials Required Item Supplier 1. Model 2301 and mounting hardware 3M 2. Rigid non-metallic conduit, inches [38-50 mm] I.D. as defined in Figure 1 Contractor 3. Concrete as required to pour floor Contractor 4. Device to cut trench in floor (for existing construction) Contractor 5. Materials to hold conduit in position while pouring floor Contractor 6. Finish flooring Contractor Installation Procedure These instructions will be used by 3M installers and the contractor to ensure proper installation of the Model 2301 Detection System and buried cables. 1. At the request of the contractor, the 3M installer will visit the site to examine the site for an acceptable environment and to locate the system in an acceptable location. System setup and testing may be required to verify the location is acceptable. 2. Using the Model 2301 Contractor Layout Plan, the contractor will position and install the Panel-to-Panel Conduit and AC Power Conduit for each system. See Figure 1. For installation details for buried AC power, see Contractor Installation Instructions for 3M Model 2301/2302 Buried Power. The Panel-to-Panel Conduit must have a minimum I.D. of inches [38-50 mm] to accept cables. If this conduit has an I.D. of less than 1.5 inch [38 mm] there will be an additional charge at installation. 3. Each bend radius in 1.5 inch [38 mm] conduit must be typical to the electrical industry. Water type 90 bends or fittings are not acceptable. 4. The contractor must avoid placing conduit or reinforcing rods in the anchor area of the mounting feet. Concrete in the area under the system mounting hardware must be a minimum of 3.5 inches [89 mm] thick for anchoring. 5. The contractor will complete the sub floor and finished floor in the installation area and will complete the AC power wiring to the site. 6. The 3M installer will install the system, anchors, and panel-to-panel wiring. 7. The contractor will provide an electrician for AC power wiring hookup to the system power cord. 8. The 3M installer will energize the system and will complete operational checks and adjustments. 2-18

23 3M Model 2301 Buried Cable (36 in., Corridor) See Model 2301 Contractor Layout Plan for exact location of conduits. Location is critical because conduits must enter openings in system mounting hardware. Notes 1. Maximum depth of inches [38-50 mm] I.D. conduit is 18 inches [457 mm] due to length of panel-to-panel cables. 2. Panel-to-panel conduit must extend 1/4-1/2 inch [6-12 mm] above the finished floor. 6. Floor in area of mounting hardware must be flat, level, and high quality concrete. Minimum concrete thickness is 3.5 inches [89 mm]. 7. See 3M Model 2300 System Layout Checklist for minimum distances to interfering objects. 3. Conduit and reinforcing rod must not interfere with anchor bolt locations. 4. Floor box for AC power must be located on the same side of the system as the patron counter. 5. For existing floors, the floor must be core drilled or trenched to accept buried conduits. Trench width should be kept to a minimum to avoid weakening the concrete in the anchor area. 2-19

24 Model 2301 Contractor Layout Plan Buried Panel to Panel Wiring Conduit 36 in. Corridor Width Electrical Supply Flush service floor box hardwired to power cord A 2.5 in. [63.5 mm] min. CL Conduit Radius to be Typical to Electrical Industry Standards Perimeter of system mounting Foot for reference only! Floor to be flat and level in this area. 1 1/2-2 in. [38-50 mm] I.D. Electrical Conduit Non-Metallic System Depth = 38 in. [965 mm] 40.5 in. [1029 mm] System Width = 45 in. [1143 mm] 3/8 in. [9.5 mm] diameter anchor locations (8), holes to be drilled by 3M technician. Keep electrical conduit and reinforcing rod clear from this area. Note: The installation and Accurate Placement of this Conduit is the Customer's/Contractor's Responsibility. Section A-A 1 1/2-2 in. [38-50 mm] I.D. Rigid, Non-Metallic Conduit 5 ft. [1523 mm] min. SystemCL to Door 4.1 in. [104 mm] 4 x 4 in. [101 x 101 mm] cutout for panel - panel conduit/wire 0.6 in. [15 mm] CL 4.5 in. [114 mm] in. [6-12 mm] 10 in. [254 mm] 21 in. [533 mm] A Notes: 1. Power sources can be from either side of M If underground power is required, use a flush mount floor box and terminate the power cord in the floor box. See "Installation Instructions Under Floor Power." 3. Floor must be level and flat in the area under the mounting foot for each panel, and a minimum of 3 1/2 in. [89 mm] thick. 4. Conduit and reinforcing rod must not be located in anchor hole area under mounting foot. 5. Cable supplied for buried wiring is adequate for conduit buried a maximum depth of 18 in. [457 mm] in. corridor complies with ADA guidelines for corridor widths. See Model 2300 Layout Checklist for Minimum Distances to interfering objects For further information or assistance, please contact: 3M Library Systems 3M Center, Bldg N-14 St. Paul, MN M Library Systems 3M Center, Bldg N-14 St. Paul, MN

25 Contractor Installation Instructions for 3M Model 2302 with Buried Cables (36 in., Corridor) Note Read all installation instructions before starting this installation procedure. If there are any questions, contact 3M Library Systems, Technical Service, , option #6. If AC power wiring is also buried, see Contractor Installation Instructions for 3M Model 2301/2302, Buried Power. Materials Required Item Supplier 1. Model 2302 and mounting hardware 3M 2. Rigid non-metallic conduit, inches [38-50 mm] I.D. Contractor as defined in Figure 1 3. Concrete as required to pour floor Contractor 4. Device to cut trench in floor (for existing construction) Contractor 5. Materials to hold conduit in position while pouring floor Contractor 6. Finish flooring Contractor Installation Procedure These instructions will be used by 3M installers and the contractor to ensure proper installation of the Model 2302 Detection System and buried cables. 1. At the request of the contractor, the 3M installer will visit the site to examine the site for an acceptable environment and to locate the system in an acceptable location. System setup and testing may be required to verify the location is acceptable. 2. Using the Model 2302 Contractor Layout Plan, the contractor will position and install the Panel-to-Panel Conduit and AC Power Conduit for each system. See Figure 1. For installation details for buried AC power, see Contractor Installation Instructions for 3M Model 2301/2302 Buried Power. The Panel-to-Panel Conduit must have a minimum I.D. of inches [38-50 mm] to accept cables. If this conduit has an I.D. of less than 1.5 inch [38 mm] there will be an additional charge at installation. 3. Each bend radius in 1.5 inch [38 mm] conduit must be typical to the electrical industry. Water type 90 bends or fittings are not acceptable. 4. The contractor must avoid placing conduit or reinforcing rods in the anchor area of the mounting feet. Concrete in the area under the system mounting hardware must be a minimum of 3.5 inches [89 mm] thick for anchoring. 5. The contractor will complete the sub floor and finished floor in the installation area and will complete the AC power wiring to the site. 6. The 3M installer will install the system, anchors, and panel-to-panel wiring. 7. The contractor will provide an electrician for AC power wiring hookup to the system power cord. 8. The 3M installer will energize the system and will complete operational checks and adjustments. 2-21

26 3M Model 2302 Buried Cable (36 in., Corridor) See Model 2302 Contractor Layout Plan for exact location of conduits. Location is critical because conduits must enter openings in system mounting hardware. Notes 1. Maximum depth of inches [38-50 mm] I.D. conduit is 18 inches [457 mm] due to length of panel-to-panel cables. 2. Panel-to-panel conduit must extend 1/4-1/2 inch [6-12 mm] above the finished floor. 3. Conduit and reinforcing rod must not interfere with anchor bolt locations. 4. Floor box for AC power must be located on the same side of the system as the patron counter. 5. For existing floors, the floor must be core drilled or trenched to accept buried conduits. Trench width should be kept to a minimum to avoid weakening the concrete in the anchor area. 6. Floor in area of mounting hardware must be flat, level, and high quality concrete. Minimum concrete thickness is 3.5 inches [89 mm]. 7. See 3M Model 2300 System Layout Checklist for minimum distances to interfering objects. 2-22

27 Model 2302 Contractor Layout Plan Buried Panel to Panel Wiring Conduit 36 in. Corridor Width Electrical Supply Flush service floor box hardwired to power cord A CL Conduit Radius to be Typical to Electrical Industry Standards 40.5 in. [1029 mm] Perimeter of system mounting Foot for reference only! Floor to be flat and level in this area. Note: The installation and Accurate Placement of this Conduit is the Customer's/Contractor's Responsibility. Section A-A CL 1 1/2-2 in. [38-50 mm] I.D. Rigid, Non-Metallic Conduit 40.5 in. [1029 mm] 4.1 in. [104 mm] 4 x 4 in. [101 x 101 mm] cutout for panel - panel conduit/wire 0.6 in. [15 mm] CL in. [6-12 mm] 21 in. [533 mm] A Notes: 1. Power sources can be from either side of M If underground power is required, use a flush mount floor box and terminate the power cord in the floor box. See "Installation Instructions Under Floor Power." 3. Floor must be level and flat in the area under the mounting foot for each panel, and a minimum of 3 1/2 in. [89 mm] thick. 4. Conduit and reinforcing rod must not be located in anchor hole area under mounting foot. 5. Cable supplied for buried wiring is adequate for conduit buried a maximum depth of 18 in. [457 mm] in. corridor complies with ADA guidelines for corridor widths. See Model 2300 Layout Checklist for Minimum Distances to interfering objects 2.5 in. [63.5 mm] min. 1 1/2-2 in. [38-51 mm] I.D. Electrical Conduit Non-Metallic System Depth = 38 in. [965 mm] System Width = 85.5 in. [2179 mm] 3/8 in. [9.5 mm] diameter anchor locations (8), holes to be drilled by 3M technician. Keep electrical conduit and reinforcing rod clear from this area. 5 ft. [1524 mm] min. SystemCL to Door 4.5 in. [114 mm] 10 in. [254 mm] For further information or assistance, please contact: 3M Library Systems 3M Center, Bldg N-14 St. Paul, MN M Library Systems 3M Center, Bldg N-14 St. Paul, MN

5. Contractor Information 3M Model 2300 Series System Layout Checklist

5. Contractor Information 3M Model 2300 Series System Layout Checklist 5. Contractor Information 3M Model 2300 Series System Layout Checklist This checklist contains the information necessary to provide the environment required to successfully install your new Model 2300

More information

Detection System Model 8800 Series

Detection System Model 8800 Series Detection System Model 8800 Series rchitect/contractor Information Package 3M Library Systems 3M Center, Building 225-4N-14 St. Paul, Minnesota 55144-1000 www.3m.com/library 78-8126-7738-9_B Copyright

More information

Site Planning Guide. Staff Workstation Model M Library Systems. Printed in U.S.A. 3M 1999 July

Site Planning Guide. Staff Workstation Model M Library Systems. Printed in U.S.A. 3M 1999 July Site Planning Guide Staff Workstation Model 995 3M Library Systems 3M Center, Building 209-1W-09 St. Paul, MN 55144-1000 800-328-0067 www.3m.com\\library Printed in U.S.A. 3M 1999 July 75-0500-2837-4 The

More information

14", 18" & 24" Fiberglass Turbo Fans Installation & Operator s Instruction Manual

14, 18 & 24 Fiberglass Turbo Fans Installation & Operator s Instruction Manual 14", 18" & 24" Fiberglass Turbo Fans Installation & Operator s Instruction Manual 09484:09#52

More information

WattStation Wall Mount User Manual

WattStation Wall Mount User Manual GE Energy WattStation Wall Mount User Manual imagination at work Table of Contents 1. Grounding Instructions...3 1.1 Safety and Compliance...3 1.2 Grounding Instructions...3 2. Installation Instructions...3

More information

Installation Instructions Studio Makeup Station

Installation Instructions Studio Makeup Station Installation Instructions Studio Makeup Station 30" and 36" Models 5-light 30" Studio Makeup Station 8-light 30" Studio Makeup Station 6-light 36" Studio Makeup Station 9-light 36" Studio Makeup Station

More information

#366. Gate Operator Pre-Installation and Site Planning. Introduction

#366. Gate Operator Pre-Installation and Site Planning. Introduction Gate Operator Pre-Installation and Site Planning Introduction Although each manufacturer s equipment has unique design characteristics and functions, gate operators are somewhat similar in many installation

More information

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions

Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions WARNING HIGH VOLTAGE 115V 4 M AP Sentinel Field Satellite Controller Metal Pedestal, Plastic Pedestal and Wall Mount Models Installation Instructions Important: For your protection and the safety of the

More information

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN Installation,Operation and Maintenance Manual PN 750-0098-001 CurrentGuard CurrentGuard Plus Surge Protective Devices CurrentGuard CurrentGuard and CurrentGuard Plus Installation, Operation and Maintenance

More information

idrive Power Cord Extender Installation Instructions MODELS: 3960M/3961S (1) 25 POWER CORD DRILL WITH 3/32 DRILL BIT

idrive Power Cord Extender Installation Instructions MODELS: 3960M/3961S (1) 25 POWER CORD DRILL WITH 3/32 DRILL BIT Wayne-Dalton Corp. P.O. Box 67 Mt. Hope, OH 44660 (888) 827-3667 www.wayne-dalton.com idrive Power Cord Extender Installation Instructions MODELS: 3960M/3961S The idrive Power Cord Extender is intended

More information

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION: 2 Please read the safety and installation instructions carefully to help ensure a correct and SAFE installation of your Second Wind Ultraviolet Germicidal Photo-catalytic Air Purifier. WARNING: FAILURE

More information

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer

BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer BAK1500 INSTALLATION/OWNER'S MANUAL Compact Amplified Subwoofer PREPARATION Getting Started Thank you for purchasing the Dual BAK1500 compact amplified subwoofer. Although Dual has attempted to ensure

More information

Installation Manual. Rev

Installation Manual. Rev Installation Manual ChargePro 620 Charging Station is a trademark of SemaConnect, Inc. All other products or services mentioned are the trademarks, service marks, registered trademarks or registered service

More information

Air Curtain. Installation, Operating and Maintenance Instructions

Air Curtain. Installation, Operating and Maintenance Instructions Installation, Operating and Maintenance Instructions Save this manual for future reference. Air Curtain Model Numbers: ES026, ES036, ES042, ES048, ES060, ES072 READ THIS OWNER S MANUAL CAREFULLY BEFORE

More information

Installation and Operation Guide

Installation and Operation Guide Bus-Scan 500 RF Installation and Operation Guide All Content and Information are Copyright 2018-2019 Robotics Technologies, Inc. Features and Information are subject to change without notice. All Rights

More information

4-SIDED BASKETBALL SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

4-SIDED BASKETBALL SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#: 4-SIDED BASKETBALL SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: 12-04-07 PART#: 98-0001-09 SERVICE & CUSTOMER INFORMATION CUSTOMER MUST HAVE PART NUMBER WHEN ORDERING ITEMS THROUGH THE SERVICE

More information

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION MODEL: PS600 HZ: 60 A model ps600 installation and service manual for federal model ps600 FEDERAL SIGNAL CORPORATION POWER SUPPLY VOLTS: SERIES: 120VAC FEDERAL SIGNAL CORPORATION UNIVERSITY PARK, IL. U.S.A.

More information

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY GC-1 Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY GENERAL INFORMATION The GC-1 heating cable controller has been designed and manufactured for

More information

Firstmate Installation Manual and User's Guide May, 2003

Firstmate Installation Manual and User's Guide May, 2003 Firstmate Installation Manual and User's Guide May, 2003 Aqualogic Marine, Inc. 506-D Terry Lane - Washington - Missouri - 63090 Warning No user serviceable parts are located inside your Firstmate unit.

More information

Installation Manual & Warranty

Installation Manual & Warranty Installation Manual & Warranty MuD Public Workplace Table of Contents What's Included... 2 Before Installation... 3 Safety Check... 4 Grounding Instructions... 4 Recommended Tools... 4 Installing the eluminocity

More information

Electric Vehicle Charging Station

Electric Vehicle Charging Station EVoReel Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL Model: Dual Output Pedestal Mount 30A EVoReel EVSE Model Numbers: With Basic EVSE: EV072-400-002A; With Intelligent ievse: EV072-410-002A;

More information

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by: Storage System Ultrasound Probe Cabinet Operator's Manual Manufactured by: CIVCO Medical Solutions 102 First Street South Kalona, IA 52247 USA 319.248.6757 / 800.445.6741 WWW.CIVCO.COM Copyright 2018 All

More information

SECTION LIFT ARM PARKING GATES

SECTION LIFT ARM PARKING GATES St. Anthony of Padua Catholic Church Phase I The Woodlands, Texas JRA Proj. No. 15004 Issued for Bidding - 1/20/2016 SECTION 11 12 33.13 LIFT ARM PARKING GATES PART 1 - GENERAL 1.01 SUMMARY A. Section

More information

Installation and Operation Guide

Installation and Operation Guide Bus-Scan CR2 RF Installation and Operation Guide All Content and Information are Copyright 2018 Robotics Technologies, Inc. Features and Information are subject to change without notice. All Rights Reserved.

More information

4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#: 4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: 05-15-07 PART#: 98-0006-06 SERVICE & CUSTOMER INFORMATION CUSTOMER MUST HAVE PART NUMBER WHEN ORDERING ITEMS THROUGH THE SERVICE

More information

Level One Electric Vehicle Charging Station Wall Mount Product Guide

Level One Electric Vehicle Charging Station Wall Mount Product Guide Level One Electric Vehicle Charging Station Wall Mount Product Guide Model # WU-120 ShorePower Technologies 2351 NW York St. Portland, OR 98664 503-892-7345 info@shorepower.com www.shorepower.com 2 Table

More information

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

The Ultimate Smart Grid Solution INSTRUCTION MANUAL ECOWISE EW30/1 The Ultimate Smart Grid Solution INSTRUCTION MANUAL Welcome! Congratulations on selecting the ECOWISE unit to manage your energy supply needs. ECOWISE units reduce the amount of electric

More information

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

TBX10A INSTALLATION/OWNER'S MANUAL 10 Sealed Enclosure with Built-in Amplifier TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier Getting Started Thank you for purchasing the Dual TBX10A 10" ported enclosure with built-in amplifier. Although Dual has

More information

OPERATING MANUAL: L/S VARIABLE-SPEED MODULAR DRIVES Model Nos. Pump Drive 07559-00 with Pump Head 07516-00 07559-00 07559-05 07559-10 07559-15 A-1299-7331 Edition 01 (US & Canada only) Toll Free 1-800-MASTERFLEX

More information

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus: 1.0 Introduction: This probe is designed to provide an additional help to automotive technicians in trouble shooting of electrical circuits problems in the car. Apart from using the normal multi tester,

More information

Creating An Accessible World ELVORON CPL.

Creating An Accessible World ELVORON CPL. Creating An Accessible World ELVORON CPL Design And Planning Guide www.garaventalift.com Please note: Dimensions provided in this Guide are for REFERENCE ONLY and should not be used for site preparation

More information

Technical Bulletin July Canoga Traffic Sensing System: Directional Boring for Installing Conduit for 702 Non-invasive Traffic Sensors

Technical Bulletin July Canoga Traffic Sensing System: Directional Boring for Installing Conduit for 702 Non-invasive Traffic Sensors Technical Bulletin July 2008 Canoga Traffic Sensing System: Directional Boring for Installing Conduit for 702 Non-invasive Traffic Sensors Introduction Using Canoga 702 Non-Invasive Traffic Sensors requires

More information

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS 1. SAFETY The MPT-250B Wire Crimp Pull Tester is a force measurement device, and as such should be operated with due caution. Operators should wear safety glasses for eye protection because the crimp under

More information

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC. INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL INS120P TASCO, INC. THIS TESTER IS DESIGNED FOR USE ONLY BY QUALIFIED ELECTRICIANS. IMPORTANT SAFETY WARNINGS mwarning Read and understand this material

More information

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250 PFS Rotameter 09/2018 Rev. 0 Variable Area Flowmeter Instruction Manual PFS-RM200, RM230, RM250 Please note: This instruction manual provides detailed information and instructions that must be read, understood

More information

GLYCOL SYSTEM MONITOR (GSM)

GLYCOL SYSTEM MONITOR (GSM) GLYCOL SYSTEM MONITOR (GSM) The Future of Beer System Diagnostics Glycol cooling systems are typically overlooked by most resturaunts. However, when the unit(s) are performing poorly or there is a component

More information

This document describes:

This document describes: Thank you for purchasing this product from ERM. We appreciate your interest in our unique product line as we try to offer our customers an alternative to today s traditional products. This programmable

More information

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS CONTACT INFORMATION Wolf Customer Service: 800-332-9513 Website: wolfappliance.com As you follow these instructions, you will notice WARNING and

More information

Level One Electric Vehicle Charging Station FREE STANDING Product Guide

Level One Electric Vehicle Charging Station FREE STANDING Product Guide Level One Electric Vehicle Charging Station FREE STANDING Product Guide Model # SC2-120 Shorepower Technologies 2351 NW York St. Portland, OR 98664 503-892-7345 info@shorepower.com www.shorepower.com 2

More information

The Ultimate Smart Grid Solution INSTRUCTION MANUAL

The Ultimate Smart Grid Solution INSTRUCTION MANUAL ECOWISE EW20/1 EW30/1 The Ultimate Smart Grid Solution INSTRUCTION MANUAL Welcome! Congratulations on selecting the ECOWISE unit to manage your energy supply needs. ECOWISE units reduce the amount of electric

More information

PPM EO-100 TM. Operation Manual

PPM EO-100 TM. Operation Manual PPM EO-100 TM Open Loop Electric Prewet Power Module Operation Manual Rev A Page 1 2/23/2010 Copyright 2008 by Cirus Controls, LLC. All Rights Reserved. No part of this material may be reproduced in any

More information

Instruction Sheet. CFRD Series. High CFM Split Rear Doors

Instruction Sheet. CFRD Series. High CFM Split Rear Doors Instruction Sheet CFRD Series High CFM Split Rear Doors C UL R US LISTED NEW THANK YOU Thank you for purchasing the CFRD Seires High CFM Split Rear Doors. Please read these instructions thoroughly before

More information

SUBMERSIBLE MINI-PUMP

SUBMERSIBLE MINI-PUMP SUBMERSIBLE MINI-PUMP Model 41287 Set up And Operating Instructions Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from

More information

(1032 mm) 30.5 (775 mm) 44 ( mm)

(1032 mm) 30.5 (775 mm) 44 ( mm) ALVARADO EDCX-EK Waist High Turnstile Technical Specifications Dimensions Unit Height: Unit Width: Unit Depth: 40.625 (1032 mm) 30.5 (775 mm) 44 (1117.6 mm) Materials Cabinet: Formed and welded 14 gauge

More information

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

INSTALLATION/OWNER'S MANUAL DP  Woofer in Enclosure INSTALLATION/OWNER'S MANUAL DP1000 10" Woofer in Enclosure Installation Thank you for purchasing the DP1000 10" Woofer with enclosure. Although Dual has attempted to make sure all of the information contained

More information

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS

TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS TRINETICS CSD SERIES OIL SWITCH INSTALLATION INSTRUCTIONS 33220900 DECEMBER 2011 Caution: The equipment covered by these installation instructions should be installed and serviced only by properly trained

More information

Turbo-House Air Inlet Installation & Operator s Instruction Manual

Turbo-House Air Inlet Installation & Operator s Instruction Manual Turbo-House Air Inlet Installation & Operator s Instruction Manual October 2011 Chore-Time Warranty Turbo-House Air Inlet Chore-Time Warranty Chore-Time Equipment ( Chore-Time ) warrants each new Chore-Time

More information

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE B-3724M ACTUATOR MANIFOLD MIDLAND MANUFACTURING CORP. 7733 Gross Point Road Skokie, Illinois 60077 Phone (847) 677-0333 FAX (847) 677-0138 WEBSITE

More information

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator Please read this manual completely before installing or operating this unit! BAGR7 Blue Air reserves

More information

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1 Linear Actuator Installation Manual warranty installation parts list January 2004 Linear Actuator Installation Manual Page 1 MA1221B12 Warranty Information Chore-Time Equipment ( Chore-Time ) warrants

More information

WF-5110R True Sine Wave Inverter

WF-5110R True Sine Wave Inverter Operator s Manual WF-5110R True Sine Wave Inverter WF-9900 Series WF-5110R ( The Inverter model number is located on the label on top of the enclosure) Distributed in the U.S.A. and Canada by ARTERRA DISTRIBUTION

More information

Sentinel Field Satellite Controller

Sentinel Field Satellite Controller WARNING HIGH VOLTAGE 115V M AP Sentinel Field Satellite Controller Installation Instructions Important: For your protection and the safety of the product user, please comply with all Caution and Warning

More information

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain 1. 2. 7 3. 4. RollSeal 1733 County Road 68 Bremen, Alabama 35033 256-287-7000 Part No 4801-5176 Rev 12-11-17 Owner s Manual RS-Divider Curtain Table of Contents 1 Warnings (Avertissements)... 3 2 Limited

More information

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company

Instruction Manual. Blink HQ Charger. Charge on. a CarCharging Company Instruction Manual Blink HQ Charger a CarCharging Company 2014 by Blink Network, LLC No part of the contents of this document may be reproduced or transmitted in any form or by any means without the express

More information

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST NOTICE TO INSTALLER: Instructions must remain with installation. SECTION: 6.10.065 Your Peace of Mind is Our Top Priority Product information presented here reflects conditions at time of publication.

More information

Installation & Operation Manual Chef Base

Installation & Operation Manual Chef Base Installation & Operation Manual Chef Base Please read this manual completely before installing or operating this unit! BACB53 BACB53M BACB71 BACB71M BACB74 BACB74M BACB83 BACB83M BACB86 BACB86M BACB96

More information

Publication No.: PSG

Publication No.: PSG TABLE OF CONTENTS PAGE 1.0 SCOPE...2 2.0 STANDARDS...2 3.0 DESIGN REQUIREMENTS...2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Resistors... 3 3.04 Interrupter... 4 3.05 SF 6 Gas System... 4 3.06

More information

Anthro Mobile Device Charging Carts and Cabinets Owners Manual

Anthro Mobile Device Charging Carts and Cabinets Owners Manual Anthro Mobile Device Charging Carts and Cabinets Owners Manual TECHNOLOGY FURNITURE Hello! Thank you for choosing Anthro. Anthro's Tablet Charging Carts and Cabinets are designed to automatically charge

More information

This document describes:

This document describes: Thank you for purchasing this product from ERM Products. We appreciate your interest in our unique product line as we try to offer our customers an alternative to today s traditional products. This universal

More information

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006 B R A N D Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006 For Sales, Support and Service phone: 407-331-4793 fax: 407-331-4708 website: www.xenotronix.com email: information@xenotronix.com

More information

Owner s Manual. 10U Wall-Mounted SmartRack Enclosure. Model: SRW10US W. 35th Street, Chicago, IL USA

Owner s Manual. 10U Wall-Mounted SmartRack Enclosure. Model: SRW10US W. 35th Street, Chicago, IL USA WARRANTY REGISTRATION Register online today for a chance to win a FREE Tripp Lite product www.tripplite.com/warranty Owner s Manual 10U Wall-Mounted SmartRack Enclosure Model: SRW10US Table of Contents

More information

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases Blue Air Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases Please read this manual completely before installing or operating this unit! BACB53 BACB71 BACB74 BACB83 BACB86 BACB96

More information

DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer

DM1016S INSTALLATION/OWNER'S MANUAL 10 Marine DVC Subwoofer DM1016S INSTALLATION/OWNER'S MANUAL 10" Marine DVC Subwoofer DM1016S INSTALLATION Preparation/Installation Please read entire manual before installation. Before You Start Disconnect negative battery terminal.

More information

TRAILER AUXILIARY POWER SYSTEM (TAPS) INSTALLATION GUIDE V1.10

TRAILER AUXILIARY POWER SYSTEM (TAPS) INSTALLATION GUIDE V1.10 TRAILER AUXILIARY POWER SYSTEM (TAPS) INSTALLATION GUIDE V1.10 TAPS INSTALLATION GUIDE V1.10 1 TRAILER AUXILIARY POWER SYSTEM CONTENTS General Information and System Logic... 2 Diagrams... 3 System Diagram

More information

Active Controlled Cooling System

Active Controlled Cooling System Active Controlled Cooling System April 2011 3267 Progress Dr Orlando, FL 32826 www.apecor.com Preliminary www.apecor.com Table of Contents General Information... 3 Safety... 3 Introduction... 3 What s

More information

Installation Guide. Marine Filter SURT023M SURT024M

Installation Guide. Marine Filter SURT023M SURT024M Installation Guide Marine SURT023M SURT024M suo0738a Product Description The APC by Schneider Electric Marine Application reduces the EMI (electro magnetic interference), produced by a connected that

More information

Installation Manual. For. Alumavator and Platinum. Vertical Installation. Elevator Boat Lifts

Installation Manual. For. Alumavator and Platinum. Vertical Installation. Elevator Boat Lifts Installation Manual For Alumavator and Platinum Vertical Installation Elevator Boat Lifts Page 2 Safety Precautions 1. Your boat lift is a heavy duty piece of equipment. It is important that all persons

More information

HBC-20 - LED HIGH BAY

HBC-20 - LED HIGH BAY To prevent death, injury or damage to property, this product must be installed in accordance to National Electrical Code (NFPA70) in the US or Canadian Electrical Code (CSA.) in Canada. Risk of fire or

More information

Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL Manual Part No

Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL Manual Part No PVR-2 Relay Units with Switches Hired Hand, Inc. 1733 Co Rd 68 PO Box 99 Bremen, AL 35033 \ Manual Part No. 4801-1022 PVR-2 Relay Units With Switches 1. WARNINGS...2 2. LIMITED WARRANTY...3 3. PHYSICAL

More information

PCS GEAR SELECT MODULE USER GUIDE v4.0

PCS GEAR SELECT MODULE USER GUIDE v4.0 PCS GEAR SELECT MODULE USER GUIDE v4.0 Ph: 1.804.227.3023 www.powertraincontrolsolutions.com Powertrain Control Solutions 1 Introduction 1.1 Included Components 1 - GSM Cable Motor Enclosur 1 - GSM Driver

More information

Elvoron Home Elevator

Elvoron Home Elevator Creating An Accessible World Elvoron Home Elevator Design And Planning Guide www.garaventalift.com Please note: Dimensions provided in this Guide are for REFERENCE ONLY and should not be used for site

More information

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH STANDBY POWER FURNACE SWITCH Easy/Tran TF Congratulations on your purchase of the Reliance Controls Easy/Tran TF furnace transfer switch. Reliance has been manufacturing transfer switches and equipment

More information

Motion Sensing Coach Light

Motion Sensing Coach Light TM Motion Sensing Coach Light Model: SH-9291AU Installation and Operating Instructions FEATURES Automatically comes on when motion is detected. Automatically turns light off. Photocell keeps the light

More information

Quick Connection Panel (QCP) Installation Guide

Quick Connection Panel (QCP) Installation Guide Quick Connection Panel (QCP) Installation Guide DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read this document first. The installer is responsible for compliance with National Electrical

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS PowerSwitch Enclosed Disconnect Switch with Receptacle (EDSR) Cat. o. EDSR Rated: 30A-600VAC Max. ISTALLATIO ISTRUCTIOS DI-000-0EDSR-00A EDSR Enclosed Disconnect Switch with Receptacle (Figure 4) OTE:

More information

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide

Podiatry Procedures Chair. For Models: Barrier-Free. User s Guide Podiatry Procedures Chair For Models: 646 647 Barrier-Free User s Guide Product Information (The information below is required when calling for service.) Dealer : Date of Purchase: Model / Serial Number:

More information

ALVARADO (1029 mm) 25 (635 mm) 36.5 (927.1 mm)

ALVARADO (1029 mm) 25 (635 mm) 36.5 (927.1 mm) ALVARADO EDCX Bullnose Waist High Turnstile Technical Specifications Dimensions Unit Height: Unit Width: Unit Depth: 40.5 (1029 mm) 25 (635 mm) 36.5 (927.1 mm) Materials Cabinet: Formed and welded 14 gauge

More information

Kitchen Tech Series Air Curtain

Kitchen Tech Series Air Curtain Installation, Operating, and Maintenance Instructions Save this manual for future reference. Kitchen Tech Series Air Curtain Model Numbers: KTECH026, KTECH036, KTECH042, KTECH048, KTECH060, KTECH072, KTECH084,

More information

Patient Care Facility

Patient Care Facility ISIMET Patient Care Facility DLA Controller Individual Room Configuration Style 1 W/ Ver 4.41 pcb & Pulse Relay pcb Installation, Operations, Start-up and Maintenance Instructions Meets all Standards for

More information

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual 25500181 Rev. A0 415 Printed in U.S.A. Copyright 2015 Federal Signal Corporation Limited Warranty The Alerting and Notification Systems

More information

Railway. assembly instructions. data and power solution. model# RAIL-LINEAR model# RAIL-90 model# RAIL-BULLPEN model# RAIL-3WAY model# RAIL-4WAY

Railway. assembly instructions. data and power solution. model# RAIL-LINEAR model# RAIL-90 model# RAIL-BULLPEN model# RAIL-3WAY model# RAIL-4WAY assembly instructions Railway data and power solution model# RAIL-LINEAR model# RAIL-90 model# RAIL-BULLPEN model# RAIL-3WAY model# RAIL-4WAY linear 90 bullpen 3-way 4-way Components and tools Safety instructions/warning

More information

RCL-7A. User s Guide. Battery Charging Station. Technology in Depth

RCL-7A. User s Guide. Battery Charging Station. Technology in Depth RCL-7A Battery Charging Station User s Guide Technology in Depth - NOTICE - This manual and the information contained herein are provided for use as a maintenance and operation guide. No license or rights

More information

Model C230 Pump Controller

Model C230 Pump Controller MANUAL Model C230 Earthsafe Systems, Inc. 7553 S. Madison Willowbrook, IL 60527 T: (630) 794-5100 F: (630) 794-5106 info@earthsafe.com www.earthsafe.com March 1, 2010 The information contained herein is

More information

OPTEVA 378 ENHANCED CASH RECYCLER TERMINAL FRONT LOAD LOBBY UNIT PLAN VIEW FRONT VIEW SIDE VIEW

OPTEVA 378 ENHANCED CASH RECYCLER TERMINAL FRONT LOAD LOBBY UNIT PLAN VIEW FRONT VIEW SIDE VIEW L00 CALL -800--600 OPTEVA 8 ENHANCED CASH RECYCLER TERMINAL WITH mm ( ") UL SAFE 4 ( 6 ") 4 ( 6 ") CONSULT WITH DIEBOLD INSTALLATION/SERVICE BRANCH FOR ADDITIONAL DETAILS AND INFORMATION. PLEASE SEE PLANNING

More information

Installation Instructions for Eaton Surge Protective

Installation Instructions for Eaton Surge Protective Contents Description Page PH Model Introduction.... 2 Safety Precautions.... 2 Operation.... 2 Preparation... 2 Installation Procedures... 3 Enclosure Mounting (New Applications - Eaton PH and PV Models)....

More information

UNDERGROUND SERVICES - SECONDARY

UNDERGROUND SERVICES - SECONDARY UNDERGROUND SERVICES - SECONDARY Contents - Underground Services... U-1 General Requirements for Underground Service...U-2 Names of Parts for Underground Service... U-3 Service Termination in a Service

More information

Feed Scale Installation & Operator s Instruction Manual

Feed Scale Installation & Operator s Instruction Manual Installation & Operator s Instruction Manual May 004 CTB Inc. Warranty CTB Inc. Warranty CTB Inc. warrants each new C-Collect product manufactured by it to be free from defects in material or workmanship

More information

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions ISIMET Drug Testing Labs DLA Controller Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions Meets all Standards for Canadian Industrial Control

More information

HA/HAB Fiberglass Wall Mount Ventilators

HA/HAB Fiberglass Wall Mount Ventilators HA/HAB Fiberglass Wall Mount Ventilators INSTALLATION, OPERATION & MAINTENANCE MANUAL IM-3100 August 2015 Throughout this manual, there are a number of HAZARD S that must be read and adhered to in order

More information

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount

Model AS-FM64 Wall Mount. Full Motion Television Wall Mount Model AS-FM64 Wall Mount Full Motion Television Wall Mount Getting Started Introduction Congratulations on the purchase of your new Audio Solutions AS-FM64 Television Wall Mount. For maximum benefit, please

More information

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

9. Non-Residential Services (Commercial, Industrial, and Agricultural) Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL PAGE: 1 of 6 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. MODEL 4 200 PSIG RATED FILTER UNIT Table of Contents I. INSTALLATION.................................................................

More information

INSTALLATION GUIDE AND USER MANUAL

INSTALLATION GUIDE AND USER MANUAL Electric Vehicle Charging Station INSTALLATION GUIDE AND USER MANUAL Model: 30A EVoCharge EVSE Model Number: EV072-300-001A Product Safety Certification: UL and cul Listed Description: SAE J1772 AC Level

More information

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse Power Pedestal DRILL \ PUNCH OUT TO SIZE REQUIRED DRILL \ PUNCH OUT TO SIZE REQUIRED Lighthouse Power Pedestal - Specifications Lighthouse Power Pedestal Dimensions Height: 44.00" (1117.60 mm) Width: 13.67" (347.22 mm)

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL EUKT05-RGBWW60 RGB + Warm White LED Strip Lighting System INSTALLATION & OPERATION MANUAL What s in the box? XC3-40500-RF RGB+W LED Controller w/ RF Remote Control EULSP0260-5.0 RGB+WW LED Strip Lighting

More information

Model T2642 Wall Mount. Television Wall Mount with Tilt Option

Model T2642 Wall Mount. Television Wall Mount with Tilt Option Model T2642 Wall Mount Television Wall Mount with Tilt Option Getting Started Introduction Congratulations on the purchase of your new Audio Solutions T2642 Television Wall Mount. For maximum benefit,

More information

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher TABLE OF CONTENTS PAGE 1.0 SCOPE... 2 2.0 STANDARDS... 2 3.0 DESIGN REQUIREMENTS... 2 3.01 Service Conditions... 2 3.02 Ratings... 3 3.03 Interrupter... 3 3.04 SF6 Gas System... 4 3.05 Terminal Pads...

More information

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL PAGE: 1 of 6 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. MODEL LCO-8 125 PSIG RATED FILTER UNIT MODEL LCO-8 Table of Contents I. Installation...............................................................

More information

TRANSDUCER INSTRUCTION MANUAL... TYPE SLIM CELL TRANSDUCER. INSTRUCTION NUMBER: AO of 9

TRANSDUCER INSTRUCTION MANUAL... TYPE SLIM CELL TRANSDUCER. INSTRUCTION NUMBER: AO of 9 CLEVELAND-KIDDER SLIM CELL TRANSDUCER INSTRUCTION MANUAL... TYPE SLIM CELL TRANSDUCER INSTRUCTION NUMBER: AO-70165 1 of 9 1.0 GENERAL INFORMATION 1.1 RECEIVING AND UNPACKING Handle and unpack the equipment

More information

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company Manufacturer of Dimensions Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com OWNERS MANUAL April

More information