IntelliTouch Expansion Center Kit

Size: px
Start display at page:

Download "IntelliTouch Expansion Center Kit"

Transcription

1 pool/spa control system IntelliTouch Expansion Center Kit Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

2 2005 Pentair Water Pool and Spa, Inc. All rights reserved This document is subject to change without notice 1620 Hawkins Ave., Sanford, NC (919) West Los Angeles Ave., Moorpark, CA (805) Trademarks and disclaimers IntelliTouch, EasyTouch, IntelliChlor, IntelliFlo, QuickTouch, MobileTouch, SAm, SAL, and FIBERworks, and the Pentair Water Pool and Spa logo are trademarks of Pentair Water Pool and Spa, Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Pentair Water Pool and Spa, Inc. disclaims proprietary interest in marks and names of others. P/N Rev A - 09/27/05

3 i Contents IMPORTANT SAFETY PRECAUTIONS... ii IntelliTouch Expansion Center Kit Contents... 1 About the Installation Guide... 1 Related Manuals... 1 Technical Support... 1 Installation Steps Summary... 2 Expansion Center Enclosure Location... 2 Expansion Center Setup Options... 2 Installing Conduit and Wire... 3 Installing the Outdoor Control Panel... 4 Connecting the Expansion Center Pre-Installed Relays... 5 Installing Auxiliary Relays (Model i5x and i10x)... 6 Connecting the Expansion Center to the Load/Power Center... 7 Connecting the Expansion Center Transformer... 9 System Wiring Diagram Glossary... 11

4 ii IMPORTANT SAFETY PRECAUTIONS Important Notice: Attention Installer: This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner and/or operator of this equipment. WARNING - Before installing this product, read and follow all warning notices and instructions which are included. Failure to follow safety warnings and instructions can result in severe injury, death, or property damage. Call (800) for additional free copies of these instructions. WARNING - Water temperature in excess of 100 degrees Fahrenheit may be hazardous to your health. Prolonged immersion in hot water may induce hyperthermia. Hyperthermia occurs when the internal temperature of the body reaches a level several degrees above normal body temperature of 98.6 F (37 C). The symptoms of hyperthermia include drowsiness, lethargy, dizziness, fainting, and an increase in the internal temperature of the body. The effects of hyperthermia include: 1) Unawareness of impending danger. 2) Failure to perceive heat. 3) Failure to recognize the need to leave the spa. 4) Physical inability to exit the spa. 5) Fetal damage in pregnant women. 6) Unconsciousness resulting in danger of drowning. WARNING - To reduce the risk of injury, do not permit children to use this product unless they are closely supervised at all times. WARNING - The use of alcohol, drugs, or medication can greatly increase the risk of fatal hyperthermia in hot tubs and spas. WARNING - Control System is intended to control heaters with built-in high limit circuits ONLY. Failure to do so may cause property damage or personal injury. WARNING - Do not use this product to control an automatic pool cover. Swimmers may become entrapped underneath the cover. WARNING - For units intended for use in other than single-family dwellings, a clearly labeled emergency switch shall be provided as part of the installation. The switch shall be readily accessible to the occupants and shall be installed at least 10 feet (3.05 m) away, adjacent to, and within sight of, the unit. CAUTION - Except for listed spa-side remote controls, install a minimum of five (5) feet from the inside wall of the pool and spa.

5 iii IMPORTANT SAFETY PRECAUTIONS (Continued) General Installation Information 1. All work must be performed by a licensed electrician, and must conform to all national, state, and local codes. 2. Install to provide drainage of compartment for electrical components. 3. If this system is used to control underwater lighting fixtures, a ground-fault interrupter (GFCI) must be provided for these fixtures. Conductors on the load side of the ground-fault circuit-interrupter shall not occupy conduit, junction boxes or enclosures containing other conductors unless such conductors are also protected by a ground-fault circuit-interrupter. Refer to local codes for details. 4. A terminal bar stamped is located inside the supply terminal box. To reduce the risk of electric shock, this terminal must be connected to the grounding means provided in the electric supply service panel with a continuous copper wire equivalent in size to the circuit conductors supplying this equipment (no smaller than 12 AWG or 3.3 mm). The bonding lug(s) provided on this unit are intended to connect a minimum of one No. 8 AWG for US installation and two No. 6 AWG for Canadian installations solid copper conductor between this unit and any metal equipment, metal enclosures or electrical equipment, metal water pipe, or conduit within 5 feet (1.5 m) of the unit. 5. The electrical supply for this product must include a suitably rated switch or circuit breaker to open all ungrounded supply conductors to comply with Section of the National Electrical Code, ANSI/NFPA The disconnecting means must be readily accessible to the tub occupant but installed at least 10 ft. (3.05 m) from the inside wall of the pool. 6. Supply conductor must be sized to support all loads. Maximum supply conductor current must be 125 Amps at 125 VAC or 63 Amps at 240 VAC.

6 iv

7 1 IntelliTouch Expansion Center Kit Contents The following items are included in the Expansion Center kit. If any items are missing please contact Technical Support. IntelliTouch Expansion Center Outdoor Control Panel. Includes motherboard and Personality board Power Relays - Models i5x and i10x (5 relays) Wiring Diagram Label - To affix to the inside front door (for models i5x and i10x) Label Sheet - A set of adhesive labels for custom identification (for outdoor control panel buttons). Use a pair of fine-tip tweezers to remove the labels from the sheet (this manual) About this Installation Guide Use the information in this manual to install the IntelliTouch Expansion Center kit contents. Related Manuals For information about configuring an Expansion Center with the IntelliTouch system, refer to the IntelliTouch System User s Guide (P/N ) For Load Center and Power Center installation instructions, refer to the Load Center and Power Center Installation Guide (P/N ) For additional IntelliTouch installation information, refer to the IntelliTouch Personality Kit Installation Guide (P/N ) and the IntelliTouch System User s Guide (P/N ) Technical Support Contact Technical Support at: Sanford, North Carolina (8 A.M. to 5 P.M.) Phone: (800) Fax: (919) Moorpark, California (8 A.M. to 5 P.M.) Phone: (800) (Ext. 6502) Fax: (805) Web sites visit and

8 2 Installation Steps Summary Note: Use the following instructions to install and connect additional expansion center enclosures to existing Load Center or Power Center. For Load Center or Power Center installation instructions, refer to the Load Center or Power Center Installation Guide (P/N ). The recommended installation steps for the Expansion Kit are as follows: Install the Outdoor Control Panel (page 4): Remove the high voltage panel from the Expansion Center enclosure and install the Outdoor Control Panel. Connect Pre-installed Relays (page 5): Connect the relay plugs to the Personality board. The four relays are pre-installed in the Power/Load Center. Installing Auxiliary Relays (page 6): Install and connect the relay(s). For models i5x and i10x. Connecting the Expansion Center to the Load/Power Center (page 7): Connect the 4-wire cable from the Load Center or Power Center to the COM port on the Personality board in the Expansion Center enclosure. Connecting the Expansion Center transformer (page 9): Connect the transformer harness to the Personality board. 6 Affixing the System Wiring Diagram Label (page 9): Affix the wiring diagram on the inside of the front door of the Expansion enclosure (for models i5s, i9+3s, i10+3d only). Expansion Center Enclosure Location All pool equipment including the Expansion Center enclosure, with the exception of the Spa-Side remote, must be located at least 10 ft. from the water s edge. Expansion Center Setup Options An Expansion Center enclosure can be a Load Center or Power Center enclosure. Install the Expansion Center enclosure s near to the main Load Center or Power Center. The Expansion Center can support all of the same high voltage connections as the main load to the Load Center or Power Center. For more information, refer to the Load Center and Power Center Installation Guide (P/N ). The Expansion Center enclosure includes COM port connections, and two actuators as does the Load Center or Power Center. The Expansion Center enclosure can be expanded to include up to five actuators (with valve module P/N ). Main Load Center (i9+3, i9+3s, i10+3d) Expansion Center (i5x or i10x) Additional Expansion Center Additional Expansion Center (3 maximum)

9 3 Installing Conduit and Wire Run the appropriate size conduit from the sub-panel to the Expansion Center (see diagram below for knockout locations). Run the appropriate conduit and wire from the main Load Center or Power Center to the Expansion Center. Run a 4-wire communication cable from the Load Center or Power Center to the Expansion Center. Supply cable(s) to the Load Center or Power Center must have a minimum current capacity suitable for the intended load(s). Supply circuit must be protected by suitable breaker rated no higher than 125 AMP. High voltage cover panel attachment screw holes Spring latch Front door removal screw GFCI knockout (approved rainproof cover required) Low voltage raceway knockout Expansion Center Enclosure

10 4 Installing the Outdoor Control Panel The Expansion Center Outdoor Control Panel includes a motherboard and Personality board. The Personality board is mounted on top of the Motherboard which mounts on the back of the Outdoor Control Panel. The Outdoor Control Panel installs in the top part of the Expansion Center. To install the Outdoor Control Panel in the Expansion Center: 1. Unlatch the front door spring latches, and open the front door of the Expansion Center. 2. Remove the cover-panel screws securing the high voltage cover-panel, and remove it from the enclosure. 3. Mount the Outdoor Control Panel in the top part of the Expansion Center. Secure it with two access screws on the bottom edge of control panel. Once secured, the Outdoor Control Panel can hinge out and down to access the Personality board for low voltage connections. 4. When finished with the relay, and transformer connections (see pages 6 through 9), close the hinged Outdoor Control Panel and secure it with the two access screws. 5. Install the cover-panel and secure it with the two retaining screws. 6. Close the front door of the Expansion Center. Fasten the two spring latches. Outdoor Control Panel Access screw Access screw Cover-panel screw (Cover-panel not shown) Cover-panel screw Retaining screw Retaining screw Expansion Center

11 5 Connecting the Expansion Center Pre-Installed Relays There are five pre-installed relays in the Expansion Center. To connect the pre-installed relay cable plugs to the Personality board: Route the power relay cable plugs up through the high voltage compartment to the Personality Board. Insert the plug into the two-pin sockets, beginning with AUX1, then AUX2, AUX3, AUX4, and AUX5. For the two-pin socket locations, refer to the diagram shown below and the System Wiring Diagrams for models i5x, and i10x. AUX1, AUX2, AUX3, AUX4, AUX5 Personality Board Feed each relay cable plug up through holes

12 6 Installing Auxiliary Relays (Model i10x only) Install additional Expansion Center axillary relays as needed. There may be as many as five additional relays. To install a relay: 1. At the Expansion Center, install the relays below the pre-installed relays. Secure in place with two retaining screws. 2. Route the relay cable plug up through the holes into the high voltage compartment to the Personality board. 3. Insert each auxiliary relay plug into the one of the two-pin sockets, beginning with AUX6, AUX7, AUX8, AUX9 and AUX10 on the Personality board. For wiring details, refer to the System Wiring Diagrams for model i10x page 10. Personality Board Relay Retaining Screws Optional Relays (5x)

13 Connecting the Expansion Unit to the Load/Power Center To connect a 4-wire cable from the Load Center or Power Center to the Personality board in the Expansion enclosure: 7 1. CAUTION - Switch the main power off at the Load Center or Power Center. 2. At the Load Center or Power Center, loosen the two access screws securing the Outdoor Control Panel. Fold down the control panel to access the Personality board. 3. Insert one end of the 4-wire cable that connects the Expansion Center to the main Load center or Power Center into plastic grommet on the bottom of the enclosure and route the wire up through the low voltage raceway to the Personality board. Connect the wires to the COM port (see page 8, step 5, 6, and 7 for details). 4. At the Expansion enclosure, Insert the 4-wire cable into plastic grommet on the bottom of the enclosure and route the wire up through the low voltage raceway to the Personality board. If necessary, for easier access to the raceway, remove the two screws securing the high voltage panel cover, and remove it from the Expansion enclosure. Outdoor Control Panel Access screw Access screw Cover-panel screw (Cover-panel not shown) Cover-panel screw Retaining screw Retaining screw Low voltage raceway Plastic grommet Expansion Center

14 8 5. Strip back the cable conductors ¼ inch. Insert the wires into the either of the COM PORTS (J7 and J8) screw terminals located on the left side of the Personality board. Secure the wires with the screws. Make sure to match the color-coding of the wires: GND = Black, Green = -DT, Yellow = +DT, and Red = +15 (see diagram below). For wiring details, refer to the Wiring Diagram for models i5x and i10x (page 10). Note: Multiple wires may be inserted into a single screw terminal. 6. Close the Expansion enclosure Outdoor Control Panel and secure it with the two access screws. 7. If removed, install the high voltage panel cover and secure it with the two retaining screws. Personality Board (Left-side) Note: COM Ports can also be used for connection to IntelliChlor and IntelliFlo Personality Board Feed each relay cable plug up through holes

15 9 Connecting the Expansion Center Transformer To connect the Expansion Center transformer wire harness onto the Personality board: Connect the transformer plug onto connector J2 on the right side of Personality board. The plug is keyed onto the pins so that the six wires point towards back of the board. From left to right the wire colors should be blue, orange, red. For the connector location, refer to the diagram shown below and the System Wiring Diagram (page 10). Note: The transformer terminals can be wired 115 VAC or 230 VAC. Refer to the System Wiring Diagram for models i5x and i10x (see page 10 for wiring connections). Affixing the System Wiring Diagram Label To affix the wiring diagram label on the Expansion Center inside front door: 1. Open the Expansion Center front door. 2. Peel the backing off the wiring diagram label. 3. Position the label in middle of the inside of the front door. Apply even pressure on the surface of the label to secure in place.

16 10 System Wiring Diagram (For models i5x and i10x)

17 11 Glossary Expansion Kit: A kit that includes additional auxiliaries to an existing Personality Kit. Requires a Load Center for each Expansion Kit. Feature Circuits: Programmable circuits that may control relays and/or valve actuators. For details see the IntelliTouch Systems User s Guide (P/N ) High Voltage Compartment: Large lower right compartment of Load Center for all high voltage wiring including circuit breakers, relays, and GFCI. Indoor Control Panel: This fourteen button remote controller with LCD (liquid crystal display) is wired to the Personality board in the Power/Load Center. The control panel can be wall mounted inside a house to control IntelliTouch Systems. is4: Four function Spa-Side remote. Can be spa wall or deck mounted. is10: Up to ten function spa-side remote with temperature changing capability. Can be spa wall or deck mounted. Load Center: Metal enclosure with power relays, transformer, and circuit breakers. The Load Center is Installed prior to Personality Kit installation. Used for distributing power for controlling IntelliTouch Systems. Also known as the sub-panel. Low Voltage Compartment: Top compartment of Load Center for all low voltage wiring. Low Voltage Raceway: Vertical space in the left side of Power/Load Center for low voltage cabling. MobileTouch Controller: Wireless controller for the IntelliTouch Systems with all the functionality of the Indoor Control Panel. Mud Box: Enclosure to provide mounting features for is10 spa-side remote that is cast into gunite, concrete, or other spa wall/deck construction. Outdoor Control Panel: Control panel with flexible hinge installed in upper portion of Power/Load Center to control IntelliTouch systems. Personality Board: The circuit board mounted on top of the Outdoor Control Panel motherboard. The Personality board defines the system capabilities. Personality Kit: Set of parts to define the capability of a system; may include: Outdoor Control Panel, temperature sensors, actuators, control panel (Indoor or MobileTouch), additional relays, actuators. Power Center: Same as Load Center with the exception of the circuit breaker base. Relay Circuits: The circuits that control the relays on the Personality Board. Connectors on top edge of the circuit board. Terminal Connector: Removable connector that may attach to circuit board with multiple sockets (anywhere from 2 to 12) to receive wires from controllers and sensors; wires held by screw terminals; multiple wires of a small enough gauge (usually 22 AWG) may be coupled to a single socket of a terminal connector. Transceiver: Circuit board with attached antenna that can send and receive radio frequency (wireless) transmissions.

18 12 Notes

19

20 P/N Rev A

IntelliTouch Pool and Spa Control System Load Center and Power Center

IntelliTouch Pool and Spa Control System Load Center and Power Center pool/spa control system IntelliTouch Pool and Spa Control System Load Center and Power Center IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Installation Guide 2008

More information

is10 Spa-Side Remote Installation Guide (For IntelliTouch and CP3800 series systems)

is10 Spa-Side Remote Installation Guide (For IntelliTouch and CP3800 series systems) is10 Spa-Side Remote (For IntelliTouch and CP3800 series systems) Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS IMPORTANT SAFETY PRECAUTIONS

More information

INTELLIVALVE 2-WAY, 3-WAY VALVE ACTUATOR

INTELLIVALVE 2-WAY, 3-WAY VALVE ACTUATOR INTELLIVALVE 2-WAY, 3-WAY VALVE ACTUATOR Press MODE button to toggle between: AUTO Mode (Green LED on): The IntelliValve Valve Actuator is controlled automatically when connected to a supported automation

More information

SpaCommand Spa-Side Remote (For EasyTouch, IntelliTouch and Compool CP3800 Series Control Systems)

SpaCommand Spa-Side Remote (For EasyTouch, IntelliTouch and Compool CP3800 Series Control Systems) SpaCommand Spa-Side Remote (For EasyTouch, IntelliTouch and Compool CP3800 Series Control Systems) Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE

More information

WARNING. Important Notice

WARNING. Important Notice CAL (Color AquaLuminator ) Light and Return Water Flow for Above Ground Pools Owners Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION

More information

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 16 1 AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Section Contents 1. Installing a mounting bracket and light

More information

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 1 AQUALUMIN III NICHELESS POOL LIGHT INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Section Contents 1. Installing a mounting bracket and light

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC-1 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH POOL AND

More information

LX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS

LX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS LX-80 COMMERCIAL POOL & SPA CONTROL INSTALLATION INSTRUCTIONS IMPORTANT SAFETY PRECAUTIONS: All wiring must be performed by a qualified electrician. Basic safety precautions and local codes should be observed

More information

INTELLICHLOR SALT CHLORINATOR COMMERCIAL SYSTEM COMSYS-8 (P/N )

INTELLICHLOR SALT CHLORINATOR COMMERCIAL SYSTEM COMSYS-8 (P/N ) INTELLICHLOR SALT CHLORINATOR COMMERCIAL SYSTEM COMSYS-8 (P/N 520973) INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS P/N 520983 Rev. B 1/2016

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC1-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH

More information

MAGICBOWL WATER EFFECT WITH FIREFX LED LIGHT FOR POOL AND SPA

MAGICBOWL WATER EFFECT WITH FIREFX LED LIGHT FOR POOL AND SPA MAGICBOWL WATER EFFECT WITH FIREFX LED LIGHT FOR POOL AND SPA INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS COLORFX Water Bowl Installation

More information

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS AQUALUMINATOR & AQL LIGHT AND RETURN WATER FLOW FOR ABOVE GROUND SWIMMING POOLS INSTALLATION AND USER'S GUIDE Contents SECTION I. IMPORTANT SAFETY INSTRUCTIONS... 2 SECTION II. LAMP HOUSING INSTALLATION...

More information

poollux Power plx-pw60 & plx-pw100

poollux Power plx-pw60 & plx-pw100 poollux Power plx-pw60 & plx-pw100 ETL LISTED Conforms to UL STD 379; Certifi.ed.to.CSA.STD.C22.2.#218.1 5005508 Installation Instructions Read all instructions before attempting to perform installation

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC-2 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH POOL AND

More information

Installation and User Guide

Installation and User Guide Wave PE5 Series Pool/Spa Combination Systems Pool Systems Spa Systems PE45343RC PE45343RCT1 PE45343RCT3 Installation and User Guide Version 4-13-06 I-Wave PE5 Installation Guide Important Safety Instructions

More information

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Installation Instructions: Read these instructions in its entirety before performing any installation work. WIR-TRAN Rated for use on 110/120VAC 60Hz applications Installation Instructions: Read these instructions in its entirety before performing any installation work. FOR USE WITH POOL AND SPA PRODUCTS ETL

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC-2 Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in its entirety before performing any installation work. FOR USE WITH POOL AND

More information

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications WPC2-XXXX-T Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications Installation Instructions: Read these instructions in their entirety before performing any installation work. FOR USE WITH

More information

AquaLuminator Light and Return Water Flow for Above Ground Pools Owner's Manual

AquaLuminator Light and Return Water Flow for Above Ground Pools Owner's Manual AquaLuminator Light and Return Water Flow for Above Ground Pools Owner's Manual IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION I. IMPORTANT

More information

Aboveground Systems Mounting Base Installation Instructions

Aboveground Systems Mounting Base Installation Instructions Aboveground Systems Mounting Base Installation Instructions Kit Contents AG systems mounting base ( the system base ) (Qty 1) 10-24 threaded brass insert (Qty 2) Screw, 10-24 x 2 inch (Qty 2) Washer, 10

More information

Underwater Pool Color-Changing LED Light

Underwater Pool Color-Changing LED Light 5g Underwater Pool Color-Changing LED Light Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Technical Support Phone: (800) 831-7133

More information

IntelliChlor Electronic Chlorine Generator Commercial System COMSYS

IntelliChlor Electronic Chlorine Generator Commercial System COMSYS IntelliChlor Electronic Chlorine Generator Commercial System COMSYS-4 520971 Installation Guide Patents pending Certified to NSF/ANSI 50 IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE

More information

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light installation Manual English Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified

More information

Installation Instructions: Read these instructions in its entirety before performing any installation work.

Installation Instructions: Read these instructions in its entirety before performing any installation work. WIR-TRAN Rated for use on 110/120VAC 60Hz applications Installation Instructions: Read these instructions in its entirety before performing any installation work. FOR USE WITH POOL AND SPA PRODUCTS ETL

More information

INTELLIBRITE 5G COLOR POOL AND SPA LIGHTS

INTELLIBRITE 5G COLOR POOL AND SPA LIGHTS INTELLIBRITE 5G COLOR POOL AND SPA LIGHTS INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INTELLIBRITE 5G White Pool and Spa LED Light

More information

INTELLIBRITE 5G WHITE AND COLOR POOL AND SPA LIGHTS

INTELLIBRITE 5G WHITE AND COLOR POOL AND SPA LIGHTS INTELLIBRITE 5G WHITE AND COLOR POOL AND SPA LIGHTS INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS INTELLIBRITE 5G White Pool and Spa

More information

Installation and User Guide

Installation and User Guide Wave PE4 Series (Mini-Wave) Pool/Spa Combination Systems Pool Systems Spa Systems PE1541RC PE1501RC Installation and User Guide Mini-Wave PE4 Installation Guide Important Safety Instructions All electrical

More information

Amerec T100 Steamer Control For use with AT and 3T steam Generators

Amerec T100 Steamer Control For use with AT and 3T steam Generators Operating Instructions WARNING The T100 control operates on 12VDC and does not present a shock hazard. Electric Shock Hazard - High voltage exists within the steam equipment. There are no user serviceable

More information

Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt. Owners Manual

Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt. Owners Manual Jazz/FX Series Spa Light Jazz Series 120 Volt only FX Series 120 Volt or 12Volt Owners Manual Fiberstars 44259 Nobel Drive Fremont, CA 94538 www.fiberstars.com 79-15014-00 REV B - 1 - CAREFULLY READ AND

More information

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter pool lighting The Treo Micro LED light is 12VAC, 2 Watt LED underwater light designed for accent Available in lengths of 30, 50, 80', 150 50,000 hour lamp life No Earth bonding required White or color

More information

Amerec T100 Steamer Control For use with AT and 3T steam Generators

Amerec T100 Steamer Control For use with AT and 3T steam Generators Operating Instructions WARNING The T100 control operates on 12VDC and does not present a shock hazard. Electric Shock Hazard - High voltage exists within the steam equipment. There are no user serviceable

More information

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

More information

PART B BRAND SPECIFIC MANUAL

PART B BRAND SPECIFIC MANUAL SPA OWNER S MANUAL IMPORTANT SAFETY INSTRUCTIONS PART B BRAND SPECIFIC MANUAL ELECTRICAL CONNECTION KEYPAD OPERATION 200 Series 200-M-B-16 Read in conjunction with Part A General Manual to form a complete

More information

JAZZ J400C (COLOR), J400AS (AUTO SYNC)

JAZZ J400C (COLOR), J400AS (AUTO SYNC) Fiberstars JAZZ J400C (COLOR), J400AS (AUTO SYNC) Owners Manual Fiberstars 44259 Nobel Drive Fremont, CA 94538 www.fiberstars.com Rev.E 08/04/04-1 - P/N 75-15046-PM CAREFULLY READ AND FOLLOW ALL SAFETY

More information

INSTALLATION GUIDE. For Carrier/Bryant Residential Power Systems

INSTALLATION GUIDE. For Carrier/Bryant Residential Power Systems INSTALLATION GUIDE For Carrier/Bryant Residential Power Systems For 100 Amp Automatic Transfer Switch/Load Center Model: KGATX0116100 16 circuit installed with 16kW generators. This Automatic Transfer

More information

Owner's/Installation Manual

Owner's/Installation Manual Owner's/Installation Manual Power Management Module (PMM) and Starter Kit NOTE: The starter kit must be purchased and installed prior to individual PMM usage. Model Numbers: 00686-0 PMM 00699-0 PMM WITH

More information

Photovoltaic Solar Plan Review

Photovoltaic Solar Plan Review PAIGE B. VAUGHAN, CBO Director of Building and Safety Phone (310) 605-5509 Fax Line (310) 605-5598 E-mail:lbutler@comptoncity.org Building & Safety Department Photovoltaic Solar Plan Review Plan Check

More information

MagicStream Laminar. Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

MagicStream Laminar. Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 1 MagicStream Laminar Installation and User s Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 2 IMPORTANT SAFETY PRECAUTIONS Important Notice: Attention Installer:

More information

DASH AUDIO KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev 01 04/16 Page 1 of 6. Verify accessory fitment at Polaris.com.

DASH AUDIO KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev 01 04/16 Page 1 of 6. Verify accessory fitment at Polaris.com. DASH AUDIO KIT P/N 2882030 APPLICATION Verify accessory fitment at Polaris.com. BEFORE YOU BEGIN Read these instructions and check to be sure all parts and tools are accounted for. Please retain these

More information

Installation and Operation Manual

Installation and Operation Manual Installation and Operating Data Installation and Operation Manual Jandy Laminar Jet Pulse Controller LPC4 H0566900A WARNING FOR YOUR SAFETY - This product must be installed and serviced by a pro fes sion

More information

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly. SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS (ELEC) This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

More information

INTELLIFLOXF AND INTELLIPROXF VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP

INTELLIFLOXF AND INTELLIPROXF VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP INTELLIFLOXF AND INTELLIPROXF VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS P/N 353061

More information

SunTouch. Solar. Systems and Parts. Catalog

SunTouch. Solar. Systems and Parts. Catalog SunTouch Systems and Parts Catalog Enlist the green team for customer convenience and energy savings The SunTouch automation system is a perfect fit for customers looking to make the most of the sun s

More information

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903)

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903) ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX 75568 (903) 897-0737 fax (903) 897-0740 Pedestal Starter-Disconnect Pedestal Starter Controller Installation Instructions

More information

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-8 Features: ACSI MODEL 1440 POWER SUPPLY INSTALLATION INSTRUCTIONS Filtered/Regulated 24 Volts DC Up to Full 2 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit

More information

INTELLIFLO VARIABLE SPEED PUMP

INTELLIFLO VARIABLE SPEED PUMP INTELLIFLO VARIABLE SPEED PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL SUPPORT If you have questions

More information

2016 Photovoltaic Solar System Plan Review List

2016 Photovoltaic Solar System Plan Review List Building Division 555 Santa Clara Street Vallejo CA 94590 707.648.4374 2016 Photovoltaic Solar System Plan Review List GENERAL PROJECT INFORMATION PLAN CHECK NO DATE JOB ADDRESS CITY ZIP REVIEWED BY PHONE

More information

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-10 ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit Protection Standby Battery

More information

Metering and Service Installation:

Metering and Service Installation: Table of Contents 1. Metering Installation Requirements, General... 1 2. Type of Service... 2 3. Definitions... 2 4. Who Provides Metering Equipment?... 2 5. Establishment of Service... 2 6. Meter Access...

More information

AquaPure Ei TM Series Replacement Kits

AquaPure Ei TM Series Replacement Kits AquaPure Ei TM Series Replacement Kits for Models APURE35/35C WARNING FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment by the

More information

Pre-Delivery Guide. How to make delivery and installation of your new hot tub fast, easy and trouble-free.

Pre-Delivery Guide. How to make delivery and installation of your new hot tub fast, easy and trouble-free. Pre-Delivery Guide How to make delivery and installation of your new hot tub fast, easy and trouble-free. Important Service Information Please make a record of the following information. It will be valuable

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 2/8/12 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. I am inspecting a building addition. They have a 480V to

More information

Installation Instructions

Installation Instructions NOTE: Read the entire instruction manual before starting the installation. This symbol indicates a change since the last issue. SAFETY CONSIDERATIONS Installing and servicing air conditioning equipment

More information

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw Small Packaged Products to 5 Tons Accessory Electric Heaters Cancels: IIK 564A--1 IIK 564A-- 11-01 Installation Instructions Electric Heaters 5 0 kw NOTE: Read the entire instruction manual before starting

More information

Auxiliary Status Switch Kit

Auxiliary Status Switch Kit Auxiliary Status Switch Kit for OR POWER-CURTAIN Part Number Ordering Number Description 6650-0151 Auxiliary Status Switch Kit for PowerTrak Jr. 6650-0150 Auxiliary Status Switch Kit for PowerCurtain Tools

More information

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw Small Packaged Products 2 to 5 Tons Accessory Electric Heaters Cancels: IIK 564A-24-2 IIK 564A-24- -02 Installation Instructions Electric Heaters 5 20 kw NOTE: Read the entire instruction manual before

More information

Technical Manual. DLM Module. This manual should remain with the unit.

Technical Manual. DLM Module. This manual should remain with the unit. Technical Manual DLM Module This manual should remain with the unit. Safety Rules SAVE THESE INSTRUCTIONS! Read the following information carefully before attempting to install, operate or service this

More information

Owner s Manual. Model 9150 Vehicular Slide Gate Operator

Owner s Manual. Model 9150 Vehicular Slide Gate Operator Owner s Manual Model 9150 Vehicular Slide Gate Operator DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 9150-065 REV D, 5/07

More information

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI II 1400-6 ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI ACSI 1426-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1092, REV. C INSTALLATION For C-UL Listed applications,

More information

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES INFORMATION BULLETIN / PUBLIC - ELECTRICAL CODE REFERENCE NO.: LAMC 93.0230 Effective: 3-24-69 DOCUMENT NO. P/EC 2002-006 Revised: 11-17-00 Previously Issued As: RGA #7-69 TEMPORARY ELECTRIC WIRING FOR

More information

Owner s Manual. Model 9100 Vehicular Slide Gate Operator

Owner s Manual. Model 9100 Vehicular Slide Gate Operator Owner s Manual Model 9100 Vehicular Slide Gate Operator DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 9100-065 REV C, 1/04

More information

Installation Instructions: HYPERION R-Lite SYSTEM

Installation Instructions: HYPERION R-Lite SYSTEM Installation Instructions: HYPERION R-Lite SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS Read

More information

This Automatic Transfer Switch with built-in Load Center includes an Express Install Kit.

This Automatic Transfer Switch with built-in Load Center includes an Express Install Kit. This Automatic Transfer Switch with built-in Load Center includes an Express Install Kit. Saves on installation time and cost, in many cases up to 50% compared to traditional transfer switch installations.

More information

Installation Instructions Used in Conjunction with the MultiWave V3.4 Software

Installation Instructions Used in Conjunction with the MultiWave V3.4 Software WARNING - Risk of Fire or Electric Shock MODEL P5043ME MultiWave Expansion Module Installation Instructions Used in Conjunction with the MultiWave V3.4 Software Disconnect all power before installing or

More information

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS The original TOMMY GATE hydraulic lift Assembling the Auxiliary Battery Box 1. Remove the cover from the auxiliary battery box by removing the two nuts and

More information

MAPNET II Transceiver Installation Instructions

MAPNET II Transceiver Installation Instructions MAPNET II Transceiver Installation Instructions Introduction This publication describes the installation procedure for the following versions of the MAPNET II Transceiver card. 4120/4100-0110 MAPNET II

More information

INTELLIFLO VSF VARIABLE SPEED AND FLOW PUMP

INTELLIFLO VSF VARIABLE SPEED AND FLOW PUMP INTELLIFLO VSF VARIABLE SPEED AND FLOW PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL SUPPORT If

More information

VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP

VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP INTELLIFLO VARIABLE SPEED ULTRA ENERGY EFFICIENT PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL

More information

E.S.P. Embedded Sensing Probes for Motor Brushes

E.S.P. Embedded Sensing Probes for Motor Brushes E.S.P. Embedded Sensing Probes for Motor Brushes 2/13 Installation & Operating Manual MN609 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com

More information

9/7/2010. Objectives. Article 90. Introduction NEC Significant Changes. Review significant revisions in the 2011 NEC

9/7/2010. Objectives. Article 90. Introduction NEC Significant Changes. Review significant revisions in the 2011 NEC 2011 NEC Significant Changes Courtesy of NJATC Courtesy of NFPA Presented By: Michael J. Johnston Executive Director of Standards and Safety, NECA Objectives Review significant revisions in the 2011 NEC

More information

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS

INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS INSTALLATION INSTRUCTIONS FOR EGA AND EGH SERIES ELECTRIC HEATERS IN V OR H SERIES UNITS NOTE TO INSTALLER The words SHALL and MUST indicate a requirement which is essential to satisfactory and safe product

More information

Installation and Operating Instructions SWITCHED NEUTRAL KIT MODEL SNK

Installation and Operating Instructions SWITCHED NEUTRAL KIT MODEL SNK Installation and Operating Instructions SWITCHED NEUTRAL KIT MODEL SNK Warning: The Gen/Tran Switched Neutral Kit should be installed by a professional electrician familiar with electrical wiring and codes,

More information

Sentinel Field Satellite Controller

Sentinel Field Satellite Controller WARNING HIGH VOLTAGE 115V M AP Sentinel Field Satellite Controller Installation Instructions Important: For your protection and the safety of the product user, please comply with all Caution and Warning

More information

These devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series

These devices meet the requirements of OSHA 29 CFR (b)(1)(ii) and OSHA 29 CFR (a) (2)(ii)(G). Airpax LEL series PGFM Series GFCI Ground Fault Protection Sensing Module INTRODUCTION The LineGard PGFM GFCI Sensing Module is a ground fault or equipment leakage sensing device designed and manufactured by North Shore

More information

STA-RITE INTELLIPRO 2 VST VARIABLE SPEED PUMP

STA-RITE INTELLIPRO 2 VST VARIABLE SPEED PUMP STA-RITE INTELLIPRO 2 VST VARIABLE SPEED PUMP INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS i CUSTOMER SERVICE / TECHNICAL SUPPORT

More information

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH IS NOT FOR "DO-IT-YOURSELF" INSTALLATION. It must be installed by

More information

POOL BARON Nicheless Color Changing LED Pool Light

POOL BARON Nicheless Color Changing LED Pool Light POOL BARON Nicheless Color Changing LED Pool Light SPECIFICATIONS: An RGB color changing pool light featuring 16 preprogrammed color modes, including white. Featuring the latest and brightest mid-power

More information

Owner s Manual. Models 6050 and 6100 Vehicular Swing Gate Operators

Owner s Manual. Models 6050 and 6100 Vehicular Swing Gate Operators Owner s Manual Models 6050 and 6100 Vehicular Swing Gate Operators DoorKing, Inc. 120 Glasgow Avenue Inglewood, California 90301 U.S.A. Phone: 310-645-0023 Fax: 310-641-1586 www.doorking.com P/N 6050-065

More information

Spring Test 7 due 05/03/2013

Spring Test 7 due 05/03/2013 Spring Test 7 due 05/03/2013 Multiple Choice Identify the choice that best completes the statement or answers the question. 1. A raceway contains two 3-phase, 3-wire circuits that supply 38 ampere continuous

More information

INSTALLATION M ANUAL

INSTALLATION M ANUAL INSTALLATION MANUAL Table of Contents UL Listings Installing the Warning Sign / Precautions Methods of Installation / Compact Installation Mounting the Secondary Entrapment / Welding Gate Arn Mounting

More information

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information INSTALLATION INSTRUCTIONS Solid-State Series!! NOTE!! Covers the following models: " CS6100 - CS7100 " CS6200 - CS9200 " CS6220 - CS9220 " CS6230 - CS9230 " CS6500 - CS7500 " CS6330 - CS9300 " CS9400 -

More information

Installation Instructions

Installation Instructions 00A0, 0A0-0A0 080A00 08A00 For Use With Vertical EconoMi$ert IV or EconoMi$ert Only SMALL ROOFTOP UNITS ACCESSORY VERTICAL EXHAUST GAS HEATING/ELECTRIC COOLING, ELECTRIC COOLING, AND HEAT PUMP UNITS TO5TON

More information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 5 Swift Lock Ready Shape Tree (Patent Pending) Instructions IMPORTANT SAFETY INSTRUCTIONS When using electrical products, basic precautions should always be followed including the following: READ AND FOLLOW

More information

Model Description Vac. Max rating Pedestal Only: 36 Utility Pedestal W/O Disconnect General Duty Series:

Model Description Vac. Max rating Pedestal Only: 36 Utility Pedestal W/O Disconnect General Duty Series: MAPA Products MPD-XX / Pedestal Disconnect 30, 60, 100 amp February 2014 Pedestal Disconnect Installation Instructions Parts List MAPA Products Fusible Rainproof Pedestal Mounted Safety Switch provides

More information

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual Combiner Box Installation & Operations Manual SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual TABLE OF CONTENTS Notices and Safety Precautions Pages 1-2 Combiner

More information

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS 7.5 Swift Lock Ready Shape Tree (Patent Pending) Instructions IMPORTANT SAFETY INSTRUCTIONS When using electrical products, basic precautions should always be followed including the following: READ AND

More information

ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. User s Manual. Model ACS

ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. User s Manual. Model ACS ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles User s Manual Model ACS PLEASE NOTE This user s manual includes the latest information at the time of printing. ClipperCreek,

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

Installation Instructions: ACCENT SYSTEM

Installation Instructions: ACCENT SYSTEM Installation Instructions: ACCENT SYSTEM READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS WILL VOID YOUR WARRANTY! INSTALLATION TIPS Read this entire

More information

City of Manhattan Beach Community Development

City of Manhattan Beach Community Development City of Manhattan Beach Community Development Phone: (310) 802-5500 FAX: (310) 802-5501 TDD: (310) 546-3501 Photovoltaic Solar Panel Plan Check Guidelines Updated: 12-20-16 ORDINANCE NO. 15-0022 MBMC 9.06

More information

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS EmerGen Switch Manual Transfer Switch OWNER S MANUAL AND INSTALLATION INSTRUCTIONS For A Series Models 6-5001, 6-7501, 10-7501, 10-12K1 PLEASE READ THIS MANUAL IN ITS ENTIRETY BEFORE INSTALLING AND/OR

More information

WIRELESS CAMPER JACK LITERATURE NUMBER REV. C CCD WARNING PERSONAL INJURY & PROPERTY DAMAGE WARNING EXPLOSION. Effective NOV 2018

WIRELESS CAMPER JACK LITERATURE NUMBER REV. C CCD WARNING PERSONAL INJURY & PROPERTY DAMAGE WARNING EXPLOSION. Effective NOV 2018 LITERATURE NUMBER 670903. REV. C WIRELESS CAMPER JACK Effective NOV 2018 Installation Operation Maintenance SAFETY ALERT SYMBOLS Safety Symbols alerting you to potential personal safety hazards. Obey all

More information

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012

COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2014 Supersedes 8/2012 COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES 506953-01 3/2014 Supersedes 8/2012 Litho U.S.A. MSAV Supply Air Blower VFD Kit INSTALLATION INSTRUCTIONS FOR MSAV (MULTI-STAGE AIR VOLUME) SUPPLY AIR BLOWER

More information

ANZI Transfer Switch and Generator Wiring Installation Addendum

ANZI Transfer Switch and Generator Wiring Installation Addendum ANZI Transfer Switch and Generator Wiring Installation Addendum Reference all appropriate documentation. NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICATIONS. THIS PRODUCT CAN BE INSTALLED BY THE

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following model: 6000 Series 85-0100B-AZ Rev 0 5/07 To ensure that the system is installed properly, provide your electrician with these

More information

Requirements for Secondary Voltage Revenue Metering (750 V and less)

Requirements for Secondary Voltage Revenue Metering (750 V and less) Requirements for Secondary Voltage Revenue Metering (750 V and less) To view the latest revision of this document go to: http://www.bchydro.com/ext/metering/ January 28, 2010 Copyright 2008 by BC Hydro.

More information

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

9. Non-Residential Services (Commercial, Industrial, and Agricultural) Section 9 2016 Electric Service Requirements, 3rd Edition Section 9 Non-Residential Services Directory Page 9.1 General Requirements 68 9.2 Direct-Connect Metering, Single Installations 69 9.3 Direct-Connect

More information

Pretest Module 24 Three-phase Service Entrance

Pretest Module 24 Three-phase Service Entrance Pretest Module 24 Three-phase Service Entrance 1. What is the most widely used three-phase service entrance system? 2. What are the three most common voltage combinations for three-phase, four-wire systems?

More information