Solenoid valves for gas VAS Double solenoid valves VCS
|
|
- Hector Osborne
- 6 years ago
- Views:
Transcription
1 Solenoid valves for gas VAS Double solenoid valves VCS roduct brochure GB Edition. Safety shut-off valves for gas Suitable for a max. inlet pressure of 500 mbar (500 ha/7 psig) Easy installation into a system Compact design saves space o extra valve required owing to integrated flow adjustment Check indication by blue ED roof of closure switch with integral visual position indicator Suitable for high-duty cycling EC type-tested and certified F, ASI/CSA and AGA approved, U listed Certified pursuant to GOST-T VAS : certified for systems up to SI and e
2 VAS,VCS Edition. VAS.. quick opening VCS.. with damping unit Application Solenoid valves for gas VAS and double solenoid valves VCS for safeguarding and controlling the air and gas supply to gas burners and gas appliances. For use in gas control and safety systems in all sectors of the iron, steel, glass and ceramics industries, also in commercial heat generation, such as the packaging, paper and foodstuffs industries. VAS..F quick opening VCS..F with proof of closure switch and pressure switch The modular design principle allows the individual components of the VAS, VCS Series to be easily assembled: e.g. quick opening, slow opening, with proof of closure switch and visual position indicator, slow opening with attached pressure switch. Ceramics industry Aluminium industry: curing oven for wheel rims Foodstuffs industry: baking oven
3 VAS,VCS Edition. Examples of application VAS Damping unit with flow adjustment lug with socket lug roof of closure switch VCS VCS Solenoid valve for gas VAS, Double solenoid valve VCS Threaded flange for pipe connections from D 0 to 65, flanged connection for sizes and for pipe connections D 0 and 50. odularly configurable with: Damping unit roof of closure switch lug (with or without socket) ressure test points ressure for inlet and/or outlet pressure Tightness control TC Bypass/pilot gas valve Attachment block for the connection of a pressure gauge, for example. ressure test points ressure Tightness control TC Bypass/pilot gas valve VBY for size Attachment block for Bypass/pilot gas valve VAS pressure gauge DG..C VAS.. DG..C Gas solenoid valve with inlet and outlet pressure switch VAS.., quick opening, pressure for inlet pressure p u and outlet pressure p d VCS.... Double solenoid valve VCS with damping unit VCS.., st valve: quick opening, quick closing, with flow adjustment nd valve: slow opening, quick closing
4 VAS,VCS Edition. Damping unit for VAS/VCS 6 8 Solenoid valve for gas VAS 6 9, Double solenoid valve VCS 6 9 Gas solenoid valve and double solenoid valve with flanged connection (ISO or ASI) for pipe connections from D 65 to 5. VAS 6 9 lug with socket lug VCS 6 9 odularly configurable with: Damping unit for VAS/VCS 6 8 roof of closure switch lug lug with socket ressure test points roof of closure switch VCS 6 9 with threaded connections for: s ressure test points ressure for inlet/interspace pressure Tightness control TC Screw plugs ressure Tightness control TC VAS 6 9 VCS 6 9 lug with socket lug ressure test points easuring adapter Damping unit for VAS/VCS 6 8 roof of closure switch Screw plugs ressure Tightness control TC Bypass adapter elief line adapter T, p Solenoid valve for gas VAS 6 9, Double solenoid valve VCS 6 9 with connection for adapter plates Gas solenoid valve and double solenoid valve with flanged connection (ISO or ASI) for pipe connections from D 65 to 5. odularly configurable with: Damping unit for VAS/VCS 6 8 roof of closure switch lug lug with socket With adapter plates, expandable with: ressure VAS 6 9: for inlet/outlet pressure VCS 6 9: for interspace/outlet pressure ressure test points Bypass or pilot gas valve VAS VCS 6 9 With two threaded connections for: s ressure test points ressure for inlet/interspace pressure Tightness control TC Expandable with relief line adapter ( T, p ) for relief line. ressure Bypass/ pilot gas valve VAS
5 p [mbar] p [mbar] VAS,VCS Edition. 5 VAS..F.. Gas solenoid valve with pilot gas valve and pressure switch VAS..F..: quick opening, quick closing, VAS as pilot gas valve with pressure VAS DG..C VCS..F.. Double solenoid valve with tightness control VCS..F..: quick opening, quick closing valves, tightness control TC 6V TC 6V VAS 5 VAS 0 VAS 0 VAS 5 VAS VAS 0 VAS 5 VAS 0, VAS 50 VAS 65 VAS 665 VAS 50 VAS 780 VAS 800 VAS 95 Flow rate VAS Gas type: natural gas V' [m /h(n)] VAS VCS 5 VCS 0 VCS 0 VCS 5 VCS 5 VCS VCS 0, VCS 50 VCS 0 VCS 50 VCS 65 VCS 665 VCS 780 VCS 800 VCS 95 Flow rate VCS Gas type: natural gas 0 5 V' [m /h(n)] VCS
6 6 VAS,VCS Edition. eplacement possibilities Solenoid valve for gas VG is to be replaced by VAS. Type code VAS Code Description VAS Gas solenoid valve Size T T-product Without inlet and outlet fl ange -0 Blind fl ange 0, 5, 0, 5,, 0, 50, 65 ominal inlet and outlet diameter F / / K Q Y W S G p internal thread T internal thread ISO fl ange Quick opening, quick closing Slow opening, quick closing ains voltage V DC ains voltage 00 V AC; 50/60 Hz ains voltage 0 V AC; 50/60 Hz ains voltage 00 V AC; 50/60 Hz ains voltage 0 V AC; 50/60 Hz roof of closure switch with visual position indicator roof of closure switch for V with visual position indicator Viewed from the right (in the direction of fl ow) Viewed from the left (in the direction of fl ow) Type code VAS 6 9 Code Description VAS Gas solenoid valve 6 9 Size T T-product 65, 80, 00, 5 ominal inlet fl ange diameter F ISO fl ange A ASI fl ange 05 ax. inlet pressure p u max. 500 mbar (500 ha/7 psig) / Quick opening, quick closing / Slow opening, quick closing K ains voltage V DC Q ains voltage 0 V AC; 50/60 Hz W ains voltage 0 V AC; 50/60 Hz A ains voltage 0 0 V AC; 50/60 Hz S roof of closure switch with visual position indicator G roof of closure switch for V with visual position indicator Viewed from the right (in the direction of fl ow) Viewed from the left (in the direction of fl ow) Electrical connection: 0 cable gland screw plugs, at the top, at the inlet and outlet pressure test points, at the top, at the inlet and outlet Accessories, right, inlet / / ressure test point for inlet pressure p u / / / / /B Bypass valve VAS, fi tted /Z ilot gas valve VAS, fi tted /V repared for breather line ½ T /E repared for breather line p - / / / / / / /B /Z /V /E - Accessories, right, outlet ressure test point for outlet pressure p d o accessories Accessories, left, inlet ressure test point for inlet pressure p u Bypass valve VAS, fi tted ilot gas valve VAS, fi tted repared for breather line ½ T repared for breather line p Accessories, left, outlet ressure test point for outlet pressure p d o accessories
7 VAS,VCS Edition. 7 Type code VCS Code Description VCS Gas solenoid valve Size T T-product Without inlet and outlet fl ange 0, 5, 0, 5,, 0, 50, 65 ominal inlet and outlet diameter p internal thread T internal thread F ISO fl ange st valve quick opening, quick closing st valve slow opening, quick closing nd valve quick opening, quick closing K Q Y W S G nd valve slow opening, quick closing ains voltage V DC ains voltage 00 V AC; 50/60 Hz ains voltage 0 V AC; 50/60 Hz ains voltage 00 V AC; 50/60 Hz ains voltage 0 V AC; 50/60 Hz roof of closure switch with visual position indicator roof of closure switch for V with visual position indicator Viewed from the right (in the direction of fl ow) Viewed from the left (in the direction of fl ow) Type code VCS 6 9 Code Description VCS Gas solenoid valve 6 9 Size T T-product 65, 80, 00, 5 ominal inlet fl ange diameter F ISO fl ange A ASI fl ange 05 ax. inlet pressure p e max. 500 mbar (500 ha/7 psig) st valve quick opening, quick closing st valve slow opening, quick closing nd valve quick opening, quick closing nd valve slow opening, quick closing K ains voltage V DC Q ains voltage 0 V AC~; 50/60 Hz W ains voltage 0 V AC~; 50/60 Hz A ains voltage 0 0 V AC~; 50/60 Hz S roof of closure switch with visual position indicator G roof of closure switch for V with visual position indicator Viewed from the right (in the direction of fl ow) Viewed from the left (in the direction of fl ow) Electrical connection: 0 cable gland screw plugs, at the top, at the inlet and outlet pressure test points, at the top, at the inlet and outlet / / / / / / B Z V E - - Accessories, right, inlet ressure test point for inlet pressure p u Accessories, right, interspace Test point for interspace pressure p z Accessories, right, interspace Test point for interspace pressure p z Bypass valve VAS, fi tted ilot gas valve VAS, fi tted repared for breather line ½ T repared for breather line p o accessories Accessories, right, outlet ressure test point for outlet pressure p d o accessories The same accessories can be selected for the left- or right-hand side.
8 8 VAS,VCS Edition. Technical data Gas types: natural gas, G (gaseous), biologically produced methane (max. 0. %-by-vol. H S) or clean air; other gases on request. The gas must be dry in all temperature conditions and must not contain condensate. CE and F approved, U listed, max. inlet pressure p u : 500 mbar (500 ha/7 psig). F approved, non operational pressure: 700 mbar (700 ha/0 psig). ASI/CSA approved: 50 mbar (50 ha/5 psig). Flow adjustment limits the maximum flow volume between approx. 0 and 00%. On VAS, the setting can be monitored on an indicator. Adjustment of the start gas rate: 0 to approx. 70%. Opening times: VAS../ quick opening: s; VAS../ slow opening: up to 0 s. Closing time: VAS../, VAS../ quick closing: < s. Ambient temperature: -0 to +60 C (- to +0 F), no condensation permitted. Storage temperature: -0 to +0 C (- to +0 F), no condensation permitted. Safety valve: Class A Group pursuant to E 6 and E 6, Factory utual (F) esearch Class: 70 and 7, ASI Z. and CSA 6.5. ains voltage: 0 V AC, +0/-5%, 50/60 Hz, 00 V AC, +0/-5%, 50/60 Hz, 0 V AC, +0/-5%, 50/60 Hz, 00 V AC, +0/-5%, 50/60 Hz, V DC, ±0%. Cable gland: 0 x.5. Electrical connection: cable with max..5 mm (AWG ) or plug with socket to E Enclosure: I 65. Duty cycle: 00%. ower factor of the solenoid coil: cos φ =. Switching frequency: VAS..: arbitrary, VAS..: there must be a period of 0 seconds between switching off and on again so that the damping is fully effective. Valve housing: aluminium, valve seal: B. Connection flanges: VAS/VCS with internal thread: p pursuant to ISO 7-, T pursuant to ASI/ASE; VAS/VCS 6 9 with ISO flange (pursuant to ISO 7005) 6, with ASI flange pursuant to ASA. VAS/VCS 9 ains voltage: 0 0 V AC, +0/-5%, 50/60 Hz. Switching frequency: max. x per minute. ax. temperature of solenoid coil: +0 C (+68 F) above ambient temperature. Current consumption at 0 C (68 F): pick-up current:.8 A, holding current: 0. A. aintenance cycles At least once per annum, at least twice per annum for biologically produced methane. If the flow rate drops, clean the strainer! Detailed information on this product Contact Sales Elster GmbH ostfach Osnabrück Strotheweg 950 otte (Büren) Germany T F info@kromschroeder.com We reserve the right to make technical modifications in the interests of progress. Copyright 0 Elster GmbH All rights reserved
Solenoid valves for gas VAS, Double solenoid valves VCS AGA
, AGA Solenoid valves for gas, Double solenoid valves Suitable for a max. inlet pressure of 500 mbar (7 psig) Easy installation into a system Compact design saves space o extra valve required owing to
More informationSolenoid valves for gas VAS, Double solenoid valves VCS
Solenoid valves for gas VAS, Double solenoid valves VCS Product brochure GB 3.1.0.2 Edition 03.08 Safety shut-off of gaseous fuels, a further development of the solenoid valves for gas VG and VS Suitable
More informationSolenoid valves for gas VAS, Double solenoid valves VCS
Solenoid valves for gas VAS, Double solenoid valves VCS Product brochure GB 3.1.0.2 Edition 07.09 Safety shut-off of gaseous fuels, a further development of the solenoid valves for gas VG and VS Suitable
More informationSolenoid valves for gas VAS, Double solenoid valves VCS
Solenoid valves for gas VAS, Double solenoid valves VCS A further development of the solenoid valves for gas VG and VS Suitable for a max. inlet pressure of 500 mbar (7 psig) Easy installation into a system
More informationPressure regulator with solenoid valve VAD Air/gas ratio control with solenoid valve VAG Variable air/gas ratio control with solenoid valve VAV
Pressure regulator with solenoid valve Air/gas ratio control with solenoid valve Variable air/gas ratio control with solenoid valve VAV Product brochure GB 3.1.0.4 Edition 03.08 All-purpose servo regulator
More informationGovernor with solenoid valve VAD Air/gas ratio control with solenoid valve VAG
Governor with solenoid valve Air/gas ratio control with solenoid valve All-purpose servo-governor for gaseous media with integrated safety valve Suitable for a max. inlet pressure of 500 mbar Outlet pressure
More informationTightness control TC. Product brochure GB Edition 12.10
Tightness control TC Product brochure GB 3.1.5. Edition 1.10 Test of both safety valves Short test period thanks to logical decision-making in the program sequence Adjustable test period which can be adapted
More information3 Edition Product brochure GB AGA
TC AGA Tightness controls Adjustable test period which can be adapted to different systems Adjustable test instant allows quick system start Maximum safety thanks to self-monitoring electronics Product
More informationButterfly valves BVG, BVA, BV..F, BVH, BVHR, BVHS, BVHM Butterfly valves with actuator IBG, IBA, IB..F, IBH, IBHR, IBHS
Butterfly valves BVG,, BV..F, BVH, BVHR, BVHS, BVH Butterfly valves with actuator IBG, IBA, IB..F, IBH, IBHR, IBHS Product brochure GB 3 Edition 03.16 For gas, air, hot air and flue gas Low leakage rate
More informationSolenoid actuator MB 7 and butterfly valves BVHM
Solenoid actuator MB 7 and butterfly valves BVHM Product brochure GB 3.2.5 Edition 03.08 For gas, air, hot air and flue gas Low leakage rate and pressure loss Robust design for a long service life Simple
More informationSafety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15
17 Elster GmbH Edition 1.17 Translation from the German 519 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas VG VG 15/1 Contents Solenoid valve for gas
More informationSafety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.
27 Elster GmbH Edition.7 Translation from the German 344297 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve Contents Solenoid valve... Contents... Safety....
More informationActuators IC 40. Product brochure GB 3 Edition 02.16
Actuators roduct brochure GB 3 Edition 02.16 For complex applications with programmable functions for flexible adjustment to the process, with statistics and fault history to support service personnel
More informationButterfly valves BVG, BVA, BV..F, BVH, BVHR, BVHS, BVHM Butterfly valves with actuator IBG, IBA, IB..F, IBH, IBHR, IBHS For gas, air, hot air and
Butterfly valves BVG,, BV..F, BVH, BVHR, BVHS, BVH Butterfly valves with actuator IBG, IBA, IB..F, IBH, IBHR, IBHS For gas, air, hot air and flue gas Low leakage rate and pressure loss High control accuracy
More informationCombination controls CG 10
Combination controls CG 0... Edition 03. GB Combination controls CG 0 Complete with strainer, two solenoid valves and servo-governor for maximum regulation precision. Special low-noise valves. Optional
More informationActuators IC 20, IC 40
Actuators IC 20, roduct brochure GB 3 Edition 06.14 IC 20 for applications with continuous or three-point step control and Automatic/anual mode changeover for easy commissioning, IC 20..E with electronic
More informationSafety 0 50 Please read and keep in a safe place Operating instructions Solenoid valve for gas VAS 1, double solenoid valve VCS 1
0 Elster GmbH Edition 0. Translation from the German 00 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas VAS, double solenoid valve VCS Cert. version
More informationOld documentation - Only for your information! Product is not available any more!
GasBloc Solenoid valve Single or multiple actuator GB 0 D0.1 Printed in Germany Edition 0.10 Nr. 0 9 1 6 Technical description The GB 0 gas valve family comprises 1, or solenoid valves as single or multiple
More informationSafety. Operating instructions Bypass/pilot gas valve VBY 8 DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 12.
07 Elster GmbH Edition.7 Translation from the German 08 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Bypass/pilot valve VBY 8 Contents Bypass/pilot valve VBY 8... Contents...
More informationChecking the usage. Slow opening/slow closing damping unit:
0 Elster GmbH Edition 0. Translation from the German 0 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Converting a solenoid valve without damping unit into a solenoid valve
More informationGasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01
Gasloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating G-M(P) 057 D01 Two stage operating mode G-(LEP)Z 057 D01 Technical Description Multifunctional gas
More informationSKP Series SKP15 U.. Gas Valve Actuator with Safety Shutoff Function
SKP Series SKP15 U.. Gas Valve Actuator with Safety Shutoff Function Document No. 155-751 SKP15 U.. Description Only when assembled to Series VG Gas valves SKP15 electro-hydraulic actuators are used in
More informationDouble solenoid valve Rp 3/8 - Rp 2 nominal diameters DMV-D/11 DMV-DLE/11
Double solenoid valve Rp 3/8 - nominal diameters DMV-D/11 DMV-DLE/11 7.30 Printed in Germany Rösler Druck Edition 10.02 Nr. 218 375 1 6 Technical description The DUNGS double solenoid valve DMV integrates
More informationSingle-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5
Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5 6.20 Printed in Germany Rösler Druck Edition 02.08 Nr. 214 6 1 6 Technical description The DUNGS safety solenoid valve MV/4, MVD, MVD/5, MVDLE/5
More informationSingle-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5
Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5 6.20 Printed in Germany Edition 02. Nr. 214 6 1 6 Technical description The DUNGS safety solenoid valve MV/4, MVD, MVD/5, MVDLE/5 is a single-stage
More informationSingle-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5
Single-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5 6.20 Printed in Germany Edition 09.17 Nr. 214 756 1 6 Technical description The DUNGS safety solenoid valve MV/4, MVD, MVD/5, MVDLE/5 is a single-stage
More informationGasMultiBloc Combined regulator and safety shut-off valves Two-stage function Integrated bypass valve MB-ZRD(LE) B07
GasMultiBloc Combined regulator and safety shut-off valves Two-stage function Integrated bypass valve MB-ZRD(LE) - B07 7. Printed in Germany Rösler Druck Edition 0.0 r. 9 Technical description The DUGS
More informationValve monitoring system VDK 200 A S02
Valve monitoring system VDK 200 A S02 8.11 Printed in Germany Edition 11.17 Nr. 214 768 1 6 Technical description The VDK 200 A S02 is the compact valve monitoring system as per EN 1643 for automatic shut-off
More informationGV-A Manufactured by Germany s Elster GmbH High-Performance Gas Solenoid Valve for Industrial Applications
No. CP-SS-1880E GV-A Manufactured by Germany s Elster GmbH High-Performance Gas Solenoid Valve for Industrial Applications Overview The GV-A High-Performance Gas Solenoid Valve for Industrial Applications
More informationManually operated safety shut-off valve HSAV HSAV/5
Manually operated safety shut-off valve HSAV HSAV/5.23 Printed in Germany Edition 02.10 Nr. 214 758 1 Technical description The DUNGS manual operated shut-off valve HSAV, HSAV/5 is semi-automatic as per
More informationSERIES 2000 GAS SAFETY SHUT OFF VALVE
APPLICATION 2 Series 00 Solenoid Valves are Safety Shut-off or Control Valves for use on gases in gas families 1, 2 and and are also suitable for use with air within the valves pressure range - see specification.
More informationGasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 403 B01 MB-D(LE) 053 B01
GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 0 B0 MB-D(LE) 05 B0 7.0 Printed in Germany Rösler Druck Edition 0.0 r. 765 6 Technical description The DUGS GasMultiBloc
More informationSKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function
SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function Document No. 155-752 SKP25 U.. Description Only when assembled to Series VG Gas valves SKP25 pressure regulating
More informationGasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 403 B01
GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 0 B0 7.0 Printed in Germany Edition 0.8 r. 765 6 Technical description The DUGS GasMultiBloc integrates filter,
More informationSingle-stage safety solenoid valves MV/4 MVD, MVD/5, MVDLE/5
Single-stage safety solenoid valves COMBUTEC MV/4 MVD, MVD/5, MVDLE/5 6.20 Printed in Germany Edition 09.12 Nr. 214 6 1 6 Technical description The DUNGS safety solenoid valve MV/4, MVD, MVD/5, MVDLE/5
More informationMBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N
GasMultiBloc Combined servo pressure regulator and safety shut-off valves MBC-00-SE MBC-700-SE MBC-100-SE MBC-00-N MBC-700-N 7.01 Max. operating pressure mbar Compact design High flow rates Low weight
More informationGasMultiBloc Combined regulator and safety shut-off valves Two-stage function MB-ZRD(LE) B01
GasMultiBloc Combined regulator and safety shut-off valves Two-stage function MB-ZRD(LE) - 12 B01 7.0 Printed in Germany Rösler Druck Edition 0.98 21 76 1 6 Technical description The DUGS GasMultiBloc
More informationMBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N
GasMultiBloc Combined servo pressure regulator and safety shut-off valves MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N 7.01 Max. operating pressure 3 mbar (36 kpa) Compact design High flow rates
More informationGasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01
GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 0-2 B0 7.0 Printed in Germany Rösler Druck Edition 08.00 r. 2 72 Technical description The DUGS GasMultiBloc integrates
More informationGasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01
GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 5-0 B0 7. Printed in Germany Rösler Druck Edition 06.0 r. 5 758 6 Technical description The DUGS GasMultiBloc integrates
More informationSeries 810: 2 Way Angle Body Valves: 1/4 to 3 NPT
Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT FEATURES Compact design, high fl ow rates Visual position indicator standard For temperatures from 22 F to +430 F / -30 C to 221 C Working pressures up
More informationGasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07
GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) 07 - B07 7. Edition 0.6 Nr. 9 6 Technical description The DUNGS GasMultiBloc integrates
More informationHigh-pressure switch for gas, air, flue gases and combustion products GW 500 A4 GW A4/2 HP
High-pressure for gas, air, flue gases and combustion products HP /2 HP 5.04 Printed in Germany Rösler Druck Edition 06.04 Nr. 241 654 1 6 Technical description The pressure is an adjustable pressure for
More informationGasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07
GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) - B07 7.08 Printed in Germany Rösler Druck Edition 08.00 Nr. 9 6 Technical description
More informationVE4000 & VE5000 SERIES
VE4000 & VE5000 SERIES CLASS "A" GAS VALVES PRODUCT HANDBOOK APPLICATION These series class A gas valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers,
More informationDouble solenoid valve Rp 2 (DN 50) DN 65 - DN 125 nominal diameters. DMV/11 eco DMV-D/11 eco DMV-DLE/11 eco
Double solenoid valve DN 65 - DN nominal diameters DMV/11 eco DMV-D/11 eco DMV-DLE/11 eco 7.38 Low power consumption Low weight Compact design High low rates Max. operating pressure 500 mbar (50 kpa) Printed
More informationGasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF
GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-00-VEF 7.03 Max. operating pressure 30 mbar (3 kpa) Compact design High flow values Low weight Low power
More informationTwo-stage safety solenoid valves ZRLE/5, ZRDLE/5
Two-stage saety solenoid valves ZRLE/5, ZRDLE/5 6.22 Printed in Germany Edition 06.16 Nr. 214 7 1 6 Technical description The DUNGS saety solenoid valve ZR... is a two-stage automatic shut-o valve as per
More informationGas Pressure Governors
7 641 ISO 9001 SKP10... SKP20... SKP13... SKP23... VGG... VGF... VGH... Electrohydraulic Actuators SKP1... Gas Pressure Governors SKP2... Gas Valves VGG... VGF... VGH... On / off safety shut-off valves,
More informationProportional Directional Valve System
roportional Directional Valve System in Sectional Design Reference: 31--9589-ENG-2 Issue: 8.215 1/2 Contents age 1 General... 3 1.1 Description... 3 1.2 pplication examples... 3 2 Technical data... 3 3
More informationSILOXA frame-mounted gas drying system, GK model, set up for outdoor installation
Technical Datasheet 1/5 Condensate trap Moulded piece, material No. 1.4571, for fl ange-mounting on gas cooler DN 150-400 Demister, material No. 1.4571 Condensate outlet via liquid shut-off valve Monitoring
More informationAutomatic shut-off valves are necessary in combustion systems to provide reliable, positive shut off of fuels.
Hauck Manufacturing Company COMBUSTION CONTROL ACCESSORIES AUTOMATIC SHUT-OFF VALVES (ASOV) Automatic shut-off valves are necessary in combustion systems to provide reliable, positive shut off of fuels.
More informationFRM. Medium Pressure Regulator. Medium pressure regulator Type FRM
FRM Medium Pressure Regulator Medium pressure regulator Type FRM Direct acting pressure regulator with adjustable setpoint springs and modular mounted safety shutoff valve (SAV) In compliance with EN 334
More informationHigh Pressure Solenoid Valves
High Pressure Solenoid Valves Available for Quick Delivery Controls the flow of Gases & Liquids up to 15,000 PSIG Natural Gas, Hydrogen & other High Pressure Gases High Pressure Cryogenics Flammable Liquids
More informationElectrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)
Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to 0.671 Cv) Order code BM-01-310-HNR-462 Series and function BM = Standard Manual override HNT = non-detented
More informationTwo-stage safety solenoid valves ZRD/5, ZRLE/5, ZRDLE/5
Two-stage saety solenoid valves ZRD/5, ZRLE/5, ZRDLE/5. Printed in Germany Rösler Druck Edition.0 Nr. 14 1 Technical description The DUNGS saety solenoid valve ZR... is a two-stage automatic shut-o valve
More informationFRM. Medium Pressure Regulator. Medium pressure regulator Type FRM
FRM Medium Pressure Regulator Medium pressure regulator Type FRM Direct acting pressure regulator with adjustable setpoint springs and modular mounted safety shutoff valve (SAV) In compliance with EN 334
More informationHigh-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP
High-pressure switch for gas, air, flue gases and combustion products 5.04 Printed in Germany Edition 02.10 Nr. 241 654 1 6 Technical description The pressure switch is an adjustable pressure switch as
More information82170/ /2-way diaphgram valves
> > ort size: DN 8... 50, G1/4... 2 (ISO G/NT) > > For high contaminated fluids > > Solenoid hermetically sealed from fluid > > Compact valve for industrial applications > > Small dimension > > Vacuum
More information3/2-way and 2 x 3/2-way Solenoid Valve for pneumatics
654 3/-way and x 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Fast response times Space saving ( x 3/-way version) Type 654 can be combined with...
More informationModular test system for diaphragm gas meters with critically operated Venturi nozzles
Modular test system for diaphragm gas meters with critically operated Venturi nozzles Product brochure GB Edition 04.07 Highly stable volume flow Unlimited test volumes Short process times Low maintenance
More information3/2-way Solenoid Valve for pneumatics
656 3/-way Solenoid Valve for pneumatics Compact design Single and manifold mounting Low power consumption Rocker pilot in DC Type 656 can be combined with... Fast response times Type 506 Type 510/511
More informationSafety. Operating instructions Protective system control FCU 500 DANGER. Contents WARNING CAUTION. Changes to edition 08.12
03251016 Edition 01.13 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Protective system control Translation from the German 2013 Elster GmbH Contents Protective system control...1
More informationDirect-acting 2/2-way plunger valve
Direct-acting 2/2-way plunger valve Type can be combined with Direct-acting and compact valve up to diameter of DN 6.0 Vibration-proof, bolted coil system Increased leak-tightness with welded plunger guiding
More informationDifferential pressure switches for air, flue and exhaust gases Pressure switch for gas
es for air, flue and exhaust gases Pressure for gas /2 5.08 Printed in Germany Edition 02.18 Nr. 223 839 1 6 Technical description The differential LGW A4 is an adjustable differential as per EN 1854 for
More informationElectrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to Cv)
Electrically operated valves Series BM-01, 3/2-way and 2 x 3/2-way G1/8 550 to 660 Nl/min (0.559 to 0.671 Cv) Order code BM-01-310-HNR-462 Series and function BM = Standard Manual override HNT = non-detented
More informationNAF-Setball ball sector valves for MC-pulp DN , PN 16-40, ANSI Class
NAF-Setball ball sector valves for MC-pulp DN 80-300, PN 16-40, ANSI Class 150-300 Fk 41.54(1)GB 08.12 Primary characteristics NAF-Setball for MC-pulp is a ball sector valve with metalto-metal seating
More informationBGD258 Series BASOTROL CE Approved Class A Gas Valve
Product Bulletin Issue Date May 21, 2010 BGD258 Series BASOTROL CE Approved Class A Gas Valve The BGD258 Series multi-function gas control valve works in conjunction with an electronic sequence control
More informationVOG Series VOG15.01xU1 Oil Safety Shut-off Valves with Proof of Closure (POC)
VOG Series VOG15.01xU1 Oil Safety Shut-off Valves with Proof of Closure (POC) Document No. 129-464 VOG15 March 30, 2010 Description Oil Safety Shutoff Valve The VOG15 is an electro-hydraulically actuated
More informationElectrically operated valves Series BM-02, 3/2-way and 2 x 3/2-way G1/4 920 to 1090 Nl/min (0.935 to Cv)
Electrically operated valves Series BM-02, 3/2-way and 2 x 3/2-way G1/4 920 to 1090 Nl/min (0.935 to 1.001 Cv) Order code BM-02-310-HNR-462 Series and function BM = Standard Manual override HNT = non-detented
More informationWARNING Warnings are indicated when mishandling this product might result in death or serious injury to the user.
CP-UM-5706E Product by Germany s Elster GmbH High-Performance Gas Solenoid Valve for Industrial Applications GV-A User's Manual WARNING Before wiring, installing, or removing the unit, be sure to turn
More informationNorth American 1599 Electro-Hydraulic Gas Shutoff Valve Bulletin 1599
Combustion North American 1599 Electro-Hydraulic Gas Shutoff Valve 1599 valves are normally closed safety shutoff valves which are controlled by an electro-hydraulic actuator. 1599 s can be ordered as
More informationV82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability
V8 series - Redundant valve manifold systems - Compact oo Safety, oo Availability and oo Safety and Availability > > Compact design - Herion valves > > Exhaust guards as standard > > SIL certified components
More informationVQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION
VQ400M SERIES PRODUCT HANDBOOK APPLICATION The VQ400M Series class A safety combination valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting
More informationVE Series. Class "A" Gas Valves. Product handbook APPLICATION CONTENTS. General. Technical. Installation and operation. Various
Class "A" Gas Valves Product handbook APPLICATION These series class A gas valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting furnaces,
More informationDifferential pressure switches for air, flue and exhaust gases GGW A4-U/2
pressure switches for air, flue and exhaust gases -U -U/2 5.03 Printed in Germany Rösler Druck Edition 07.03 Nr. 215 168 1 6 Technical description The differential is an adjustable differential for automatic
More information/2-way piston valves
> > ort size: DN 15... 100, Flange connection, ressure rating N 40 > > djustable: Damped operation () > > Valve operates without differential pressure (Zero delta ) > > Valve piston with TFE guide-ring
More informationPressure switch for gas, GW 500 A4 GW 500 A4/2
for gas, air, flue gases and combustion products /2 5.09 Printed in Germany Edition 02.18 Nr. 255 960 1 6 Technical description The pressure is an adjustable pressure as per EN 1854 (GW 6000 A4 as per
More information2/2-way Compact Solenoid Valve, G 1/4 - G 1/2
2/2-way Compact Solenoid Valve, G 1/4 - G 1/2 Stainless steel body Type 6027 Compact can be combined with Direct-acting, normally closed Brass and stainless steel body Electrical connection cable plug
More information3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base
3/2-way Small Solenoid Valve, G 1/8 - G 1/4 and sub-base Sub-base Direct-acting, normally closed and normally open Brass and stainless steel body Electrical cable plug Form A With or without manual override
More informationFunctional Description HU /2012. Compact Hydraulic Power Packs USMA 05. Replaces HA /2008. p max 3600 PSI (250 bar) 4.
Compact Hydraulic ower acks USA 05 p max 3600 SI (250 bar) 4.5 G (17 L/min) 12/2012 Replaces HA 7211 6/2008 Compact hydraulic power packs for the use in lifting platforms, elevating tables, ramps, presses,
More informationType 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518
3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics Type 658 standard standard High flow-rate capacity Reduced power consumption Single or manifold mounting Standard-, EEx m and EEx i versions
More informationElectrically operated valves Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv)
Series MF-04 for manifold mounting, 5/2- and 5/3-way G1/8 360 Nl/min (0.366 Cv) Order code MF-04-510-HN-442 Series and function (plug pins on top, see pictures) 441 = 12 V DC without plug socket 442 =
More information2/2 way Coaxial valve CXRM compact, pilot operated Modular design
2/2 way Coaxial valve CXRM compact, pilot operated Modular design Model code (also example order) CXRM 2/2 F C 2 08 040 038 V Standard NC (closed when de-energised) With external 3/2-way pilot valve 4
More informationPGM Prepiped Gas Manifold
PGM Prepiped Gas Manifold PGM-1 Edition 03-09 Prepiped and assembled for easy installation Suitable for single and multiple burner applications Automatic safety shutoff valves with visual indication and
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/2-, 5/2-5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More informationVQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION
VQ400M SERIES PRODUCT HANDBOOK APPLICATION The VQ400M Series class A safety combination valves are used for control and regulation of gaseous fluids in gas power burners, atmospheric gas boilers, melting
More informationVQ1000. How to Order Manifold. Kit type
- - ase Mounted VQ000/000 Manifold type D-sub connector ort Solenoid Valve Flat ribbon cable Connector Serial Directional Control Valves VQ000 How to Order, Manifold Options VQ000 How to Order, Manifold
More information5.0 MPa Pilot Operated 2/3 Port Solenoid Valve & Check Valve
5.0 Ma ilot Operated /3 ort Solenoid Valve & Check Valve Series VCH VCH4/4: ort VCH40: 3 ort VCHC40: Check Valve ilot Operated ort Solenoid Valve [Option] Series VCH40 Stable responsiveness Response time
More informationProportional Pressure Reducing Valve PDM08130
Proportional Pressure Reducing Valve PDM08130 up to 80 bar up to 10 l/min Cartridge valves Control electronics Connection housings 486 1. DESCRIPTION 1.1. GENERAL According to DIN-ISO 1219, HYDAC proportional
More informationSpecial valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.
Special valves Operation Series Page no. Function 2/2 Body material Brass Aluminium Solenoids IP Protection class Explosion proof class IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64 EEx
More information2/2-way Globe Valve for media up to +180 C, DN
2/2-way Globe Valve for media up to +180 C, DN 10-100 Compact globe valve version Flange, threaded and welded ports as standard Stainless steel 316L valve body Available with flow direction below and above
More informationSeries 26d Ball Valve
Stainless Steel Series 26d Ball Valve Application Tight-closing ball valve made of stainless steel for corrosive media, especially to meet high process requirements in chemical plants: Nominal sizes DN
More information82610/ /2-way seat valves
> > ort size: DN 1,5... 5, 1/8... 3/8 (ISO G/NT) > > Suitable for vacuum > > High flow rate > > Functional compact design > > Solenoid interchangeable without tools (c) > > Valve operates without pressure
More information3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics
/-, 5/- 5/-way Solenoid Valves for process pneumatics Type 658 stard High flow-rate capacity Reduced power consumption Single or manifold mounting stard Type 658/659 can be combined with... Stard-, EEx
More informationAcoustic Signals Industrial Airhorns > AP Series Product overview
udible Signals INDUSTRIL IRHORNS SOUNDERS coustic Signals Industrial irhorns > Series roduct overview The Series of air horns are suitable for general purpose signalling where high output is required such
More informationMetal tube variable area flowmeter for gases, liquids and steam
Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,
More informationHoneywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION
Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION The VV Series class A vent valves are intended to be used in combination with the VQ400M series combination valve.
More informationBlack Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk
Black Teknigas Powerseat Eco Gas Safety Shut-Off Valve Technical, and Maintenance Details WattsIndustries.co.uk Safety shut off valves for gas, air and oil EN161 approved; EC certificated Robust construction
More informationFor high-viscosity oils and fluid grease of NLGI grades 000, 00 For use in SKF MonoFlex single-line centralized lubrication systems
Gear pump unit roduct series KFB For high-viscosity oils and fluid grease of NLGI grades 000, 00 For use in SKF MonoFlex single-line centralized lubrication systems SKF gear pump units of the KFB product
More information