1 1-kV Safefront 00 mp ulletin 0-10 Page mp air-insulated bushings accept IEEE Standard 00 mp elbows "Elbows" compartment label is visible with doors closed Parking stands are unpainted stainless steel and provide space and grounding for portable devices olt head with grounding eye for attachment of ground wire 11-gauge steel equipment plate is rigid for easier elbow operation ll six bushing locations are punched so additional bushings may be field installed when circuit requirements change Corrosion proof nameplate is located to provide easy access for the operator us and fuse schematic is orange-colored vinyl for high visibility Field-Proven Components including bushings specifically designed for "in-air" operation gives you long-term reliable service Standard Cable Training means quick, economical installation and assures proper operation for the life of the equipment Deep Elbow Compartment and careful placement of bushings and parking stands makes switching and grounding easier and safer Tamper-Resistant meets National and Regional Integrity Standards and virtually eliminates the entrance of airborne contamination to reduce maintenance Coordinated padlock and penta-head or optional hex-head bolt (top and bottom) provides bolted door security with visual confirmation by supervisory personnel. Security bolt is made captive with a stainless steel washer compressed to an oval shape to severely discourage removal. In-ir Insulation eliminates leaking or contamination of insulating medium for long trouble-free operation In-ir Visibility allows visual inspection of all components without the inconvenience or expense associated with equipment which must be de-energized for inspection In-ir ccessibility means every connection may be checked and tightened using hot stick tools without de-energizing the equipment "Transformer" compartment label is visible with doors closed Clear-polycarbonate door safety barriers (transformer side only) allows visual inspection without removal Ground lugs on each wall of the elbow and transformer compartment accept # - #2/0 ground cable Superlife finish includes phosphatizing, rust-inhibiting epoxy primer and Pad- Mount Green (Munsell 7GY 3.29/1.) polyurethane top coat - over mils dry Heavy-duty 11-gauge steel enclosure is all-welded construction for long life Door-holder rods are stainless steel and hold the doors open 100 degrees or 10 degrees Clip-Mounted Current-Limiting Provisions ENCLOSURE OPTIONS: 1) 0.1 #02H32 luminum 2) 12-gauge #30L Stainless Steel Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

2 1-kV Safefront 00 mp ulletin 0-10 Page Cable Training and olt Locations 90" 2. X 2. Galv. Square Washer Ø." olts " 0" 8." lternate #1 28." " " Min. Cable Length Measured from Top of Pad racket # Ø." olts 1." lternate #2 90" 3.37" " 3.37" " 0 kv. 17" 3 ottom Open Code 3 Projected Centerline Equipment Plate 28." " olt Locations 13" " Ø 0.7" " Ø 1. Conductor 0. x " Copper us ir-insulated ushing 21.87" # Insulator # Insulator 27" Min. 20" " Section and Pad Dimensions Top View of One Phase ushing wells may be added if circuit requirements change - see page 17 in this bulletin. EPM-PTS-1-311P-E-CM-0KV Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

3 1-kV Safefront 00 mp ulletin 0-10 Page One Line Diagram Three Phase Two Ways per Phase 00 mp ir-insulated ushings 10 mp () Clip Mounted CL Provisions 8.3/1. kv Grounded Wye Design 9 kv IL "Elbows" Label is Visible with Doors Closed 90" "Transformers" Label is Visible with Doors Closed 90" "Load" 28." ".37" 0 kv Provision for Padlock and Security olt, Top and ottom View Doors & Door Safety arriers Removed 90" " 88" 8" ottom Open " 0" ir-insulated ushings 8" " Insulators Code GPO-3 arrier affled Sectional Door Safety arriers 13" Projected Centerline Equipment Plate " 0 kv 28." " Ø 0.7" Two Ground Provisions Each Side 20" 2 27" 17" affled Section Section ushing wells may be added if circuit requirements change - see page 17 in this bulletin. EPM-PTS-1-311P-E-CM-0KV Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

4 1-kV Safefront 00 mp ulletin 0-10 Page 2018 Cable Training and olt Locations 90" 2. X 2. Galv. Square Washer Ø." olts 1." 0" 8." lternate #1 10.7" 17.7" 17.7" 10.7".37".37" " Min. Cable Length Measured from Top of Pad racket # Ø." olts 1." lternate #2 90" 3.37" " 3.37" " 0 kv. 17" 3 ottom Open Code 3 Projected Centerline Equipment Plate 10.7" 17.7" 17.7" 10.7".37".37" olt Locations 13" " Ø 0.7" " Ø 1. Conductor 0. x " Copper us ir-insulated ushings 10.7" # Insulator " Min. 20" " Section and Pad Dimensions Top View of One Phase EPM-PTS-1-321P-E-CM-0KV Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

5 1-kV Safefront 00 mp ulletin 0-10 Page 2018 One Line Diagram Three Phase Three Ways per Phase 00 mp ir-insulated ushings 10 mp () Clip Mounted CL Provisions 8.3/1. kv Grounded Wye Design 9 kv IL "Elbows" Label is Visible with Doors Closed 90" "Transformers" Label is Visible with Doors Closed 90" "Load" 10.7" 17.7" 17.7" 10.7" 0".37".37" 0 kv Provision for Padlock and Security olt, Top and ottom View Doors & Door Safety arriers Removed 90" " 88" 8" ottom Open " 0" ir-insulated ushings 8" " Insulators Code GPO-3 arrier affled Sectional Door Safety arriers Projected Centerline Equipment Plate 10.7" 17.7" 17.7" 10.7" 13" " 0 kv.37".37" Ø 0.7" Two Ground Provisions Each Side 20" 2 27" 17" affled Section Section EPM-PTS-1-321P-E-CM-0KV Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

6 1-kV Safefront 00 mp ulletin 0-10 Page 2018 Cable Training and olt Locations X 2. Galv. Square Washer Ø." olts " " 8." lternate # ".37" " Min. Cable Length Measured from Top of Pad racket # Ø." olts 1." lternate # " 0" 9.37" 0" 7 kv. 20" 3" ottom Open 29" Code 3" Projected Centerline ".37" olt Locations Equipment Plate 1" " 29" Ø 0.7" 7 Ø 1. Conductor 0. x Copper us ir-insulated ushing 2.1 # Insulator # Insulators 30" Min. 20" 7 Section and Pad Dimensions Top View of One Phase ushing wells may be added if circuit requirements change - see page 17 in this bulletin. EPM-PTS-1-311P-E-CM-7KV Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

7 1-kV Safefront 00 mp ulletin 0-10 Page One Line Diagram Three Phase Two Ways per Phase 00 mp ir-insulated ushings 10 mp () Clip Mounted CL Provisions 8.3/1. kv Grounded Wye Design 9 kv IL "Elbows" Label is Visible with Doors Closed 10 "Transformers" Label is Visible with Doors Closed "Load" " ".37" 7 kv Provision for Padlock and Security olt, Top and ottom View Doors & Door Safety arriers Removed 10 8" 70" 100" 98" ottom Open ir-insulated ushings 7 Insulators Code GPO-3 arrier affled Sectional Door Safety arriers 7 " 8" 1" 7 kv Projected Centerline Equipment Plate " ".37" Ø 0.7" Two Ground Provisions Each Side 20" 2 30" 20" affled Section Section ushing wells may be added if circuit requirements change - see page 17 in this bulletin. EPM-PTS-1-311P-E-CM-7KV Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

8 1-kV Safefront 00 mp ulletin 0-10 Page Cable Training and olt Locations X 2. Galv. Square Washer Ø." olts 1." " 8." lternate #1 10.7" 21." 21." 10.7".37".37" " Min. Cable Length Measured from Top of Pad racket # Ø." olts 1." lternate # " 9.37" 20" 0" 0" 7 kv. 3" ottom Open 29" Code 3" 10.7" Projected Centerline 21." 21." 10.7".37".37" Equipment Plate 1" " 29" 7 Ø 1. Conductor 0. x Copper us ir-insulated ushings 10.7" # Insulator # Insulators 13.37" 30" Min. 20" 7 olt Locations Ø 0.7" Section and Pad Dimensions Top View of One Phase EPM-PTS-1-321P-E-CM-7KV Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

9 1-kV Safefront 00 mp ulletin 0-10 Page One Line Diagram Three Phase Three Ways per Phase 00 mp ir-insulated ushings 10 mp () Clip Mounted CL Provisions 8.3/1. kv Grounded Wye Design 9 kv IL "Elbows" Label is Visible with Doors Closed 10 "Transformers" Label is Visible with Doors Closed 10 "Load" 10.7" 21." 21." 10.7" ".37".37" 7 kv Provision for Padlock and Security olt, Top and ottom View Doors & Door Safety arriers Removed 10 8" 70" 100" 98" ottom Open ir-insulated ushings 7 Insulators Code GPO-3 arrier affled Sectional Door Safety arriers 7 " 8" Projected Centerline Equipment Plate 10.7" 21." 21." 10.7" 1" " 7 kv.37".37" Ø 0.7" Two Ground Provisions Each Side 20" 2 30" 20" affled Section Section EPM-PTS-1-321P-E-CM-7KV Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

10 1-kV Safefront 00 mp ulletin 0-10 Page Cable Training and olt Locations 11" 2. X 2. Galv. Square Washer Ø." olts " " 8." lternate #1 3." ".37" " Min. Cable Length Measured from Top of Pad racket # Ø." olts 1." lternate #2 11".37".37" 3" " " 17 kv. 3" Projected Centerline 3." " olt Locations ottom Open Equipment Plate 1" " 29" 29" Ø 0.7" 7 Ø 1. Conductor 0. x Copper us ir-insulated ushing Code # Insulator # Insulators 2.87" Min. 20" 7 Section and Pad Dimensions Top View of One Phase ushing wells may be added if circuit requirements change - see page 17 in this bulletin. EPM-PTS-1-311P-E-CM-17KV Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

11 1-kV Safefront 00 mp ulletin 0-10 Page One Line Diagram Three Phase Two Ways per Phase 00 mp ir-insulated ushings 10 mp () Clip Mounted CL Provisions 8.3/1. kv Grounded Wye Design 9 kv IL "Elbows" Label is Visible with Doors Closed 11" "Transformers" Label is Visible with Doors Closed 11" "Load" 3." 30.1 ".37" 17 kv Provision for Padlock and Security olt, Top and ottom View Doors & Door Safety arriers Removed 11" 8" 70" " ottom Open ir-insulated ushings 7 Insulators Code GPO-3 arrier affled Sectional Door Safety arriers 7 " 8" 1" 17 kv Projected Centerline Equipment Plate " 3." " Ø 0.7" Two Ground Provisions Each Side 20" 2 affled Section Section ushing wells may be added if circuit requirements change - see page 17 in this bulletin. EPM-PTS-1-311P-E-CM-17KV Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

12 1-kV Safefront 00 mp ulletin 0-10 Page Cable Training and olt Locations 11" 2. X 2. Galv. Square Washer Ø." olts 1." " lternate #1 8." 10.7" 2.7" 2.7" 10.7".37".37" " Min. Cable Length Measured from Top of Pad racket # Ø." olts 1." lternate #2 11".37".37" 3" " " 17 kv. 3" Projected Centerline 10.7" 2.7" 2.7" 10.7" olt Locations.37".37" ottom Open Equipment Plate 1" " 29" 29" Ø 0.7" 7 Ø 1. Conductor 0. x Copper us ir-insulated ushings Code 10.7" # Insulator # Insulators 1.1 Min. 20" 7 Section and Pad Dimensions Top View of One Phase EPM-PTS-1-321P-E-CM-17KV Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

13 1-kV Safefront 00 mp ulletin 0-10 Page One Line Diagram Three Phase Three Ways per Phase 00 mp ir-insulated ushings 10 mp () Clip Mounted CL Provisions 8.3/1. kv Grounded Wye Design 9 kv IL "Elbows" Label is Visible with Doors Closed 11" "Transformers" Label is Visible with Doors Closed 11" "Load" 10.7" 2.7" 2.7" 10.7" ".37".37" 17 kv Provision for Padlock and Security olt, Top and ottom View Doors & Door Safety arriers Removed 11" 8" 70" " ottom Open ir-insulated ushings 7 Insulators Code GPO-3 arrier affled Sectional Door Safety arriers 7 " 8" Projected Centerline Equipment Plate 10.7" 2.7" 2.7" 10.7" 1" " 17 kv.37".37" Ø 0.7" Two Ground Provisions Each Side 20" 2 affled Section Section EPM-PTS-1-321P-E-CM-17KV Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

14 1-kV Safefront 00 mp ulletin 0-10 Page Specification - Page 1 of 3 General The fusible primary transformer station shall be 1 kv class, 9 kv IL, 00 ampere continuous current, suitable for use on 8.3/1. kv grounded wye max design systems. The transformer station shall be constructed for connection to the utility system with 1 kv separable insulated connectors as described in IEEE Standard 38 latest revision (separable insulated connectors shall be supplied by the user). The transformer station shall be designed for and accept standard outdoor pole-type distribution transformers in a compartment separated from the elbow compartment by a steel equipment plate. Provision for clip-mounted currentlimiting fuses on the source side of the transformers shall be located in the transformer compartment in a position that allows fuse replacement with hot-line tools. Separate access shall be provided for each compartment. door safety barrier shall be provided inside the door(s) on the transformer compartment as recommended in IEEE Standard C2 (National Electrical Safety Code) Rule 381G. Tamper resistance shall meet the Security requirements of IEEE Standard C (Pad-Mounted Equipment Integrity). Together, the tamper resistance and the door safety barrier shall resist unauthorized entry, protect authorized and unauthorized persons, and provide positive safety features when installed in areas accessible to the general public. The primary transformer station shall be constructed for outdoor installation in areas subject to heavy precipitation and in areas with windblown contamination. The equipment shall be air-insulated and completely assembled prior to shipment. Construction The enclosure shall be tamper-resistant, all-welded construction utilizing 11-gauge minimum sheet steel. Corner plates and braces shall be used as necessary to assure rigidity. The enclosure top shall be cross-kinked to provide watershed and rigidity. The enclosure shall be open bottom with a 1-inch flange inside, all around. Separate compartments shall be provided for cable termination and for transformers each compartment equipped with its own individual access door(s) furnished with a stainless steel door holder that will latch the door open 100 degrees and 10 degrees and resist accidental closing. The equipment plate separating the two compartments shall be full length, constructed with 11-gauge minimum sheet steel braced to assure rigidity when operating the elbows. Doors shall be provided with provisions for padlocking and a recessed penta-head (or hex-head) security bolt to prevent unauthorized entry (coordinated to prevent installation of the padlock until the security bolt is tightened when closing the door(s) and to prevent a wrench from operating the security bolt until the padlock is removed when opening the door(s)). The security bolt shall be made captive with a stainless steel washer compressed to an oval shape to severely discourage removal. Hinges shall be stainless steel (with stainless steel pins not less than inch diameter) and shall be welded to both the enclosure and the door(s) to maintain door alignment for the life of the equipment., which meets the tamper resistance requirements of IEEE Standard C , shall be provided in the top and bottom sill of the elbow compartment side of the enclosure and in the top and bottom sill of the transformer compartment side of the enclosure. Open-pore filter foam shall be installed in the outermost ventilation area to prevent entry of wildlife including wasps and similar size insects. The protective finish shall include necessary grinding, cleaning and phosphatizing, two-component rust-inhibiting epoxy primer and a Pad-Mount Green two-component polyurethane top coat finish (Munsell color 7GY 3.29/1.). The primer and top coat shall be electronically monitored during application to insure proper ratio and mixing of each component. Total average thickness of paint (after curing) shall be not less than mils. The protective coating shall meet the Coating System requirements of IEEE Standard C (Pad-Mounted Equipment Integrity). Removable lift provisions, adequate to withstand handling with normal utility equipment, shall be provided on the outside of the enclosure. Threaded openings for lift provision bolts shall be blind holes to prevent the entrance of wire or other foreign objects into the enclosure when lift provisions are removed. ushings and Terminals ushings shall be 00 ampere # , 2 kv class (1.2 kv to ground) ir-insulated ushings, 12 kv IL, per IEEE Standard Fig. 13 (Interface 11: a 00 and 900 Deadbreak Interface 1 and 2 kv class) for use with either 8.3/1. kv or 1.2/2.3 kv separable insulated connectors (Elastimold, Eaton s Cooper Power Systems or other approved equal). The bushings shall be pressuremolded cycloaliphatic epoxy with a 1.2-inch diameter tin-plated aluminum conductor on the air-insulated side that is drilled and tapped 0.2-inch 11UNC x 1.2-inch deep to provide direct connection of the bus and/or live parts. Leakage distance from the apparatus connection end of the bushing to ground shall be not less than 30 inches to assure trouble-free operation in a wet and/or contaminated environment. Integral shielding shall be Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

15 1-kV Safefront 00 mp ulletin 0-10 Page Specification - Page 2 of 3 provided to eliminate partial discharge caused by offcenter mounting and mounting holes that may have sharp edges or burrs. ushings shall mount in a inch diameter opening and bolt in place to allow field replacement with standard tools. The bushing mounting bolts shall be self-locking stainless steel serrated-flange hex-head bolts that cut through the enclosure protective finish to ground the integral shielding of each bushing. To assure adequate strength for apparatus support, the bushing shall withstand a minimum cantilever loading of 00 pounds for five minutes without damage. The bushing interface shall be free of all voids, holes and heat sinks to assure proper mating with separable insulated connectors. Each bushing shall be tested in free air, mounted in a grounded steel plate not less than 10 inches x 10 inches, with an insulated protective cap (Eaton s Cooper Power Systems #DPC2 or equal) installed on the interface to accurately simulate operating conditions (gas or liquid dielectric on the interface shall not be acceptable for this test). Each bushing shall meet the requirements for 2 kv devices in accordance with the test values of IEEE Standard 38 (latest revision), including 100 percent production testing. us and s us shall be copper with all burrs and sharp corners removed prior to installation. clips and/or fuse hinges shall be keyed to prevent rotation and to maintain alignment. Positive pressure shall be assured by use of stainless steel fasteners and lock washers or compression washers at all connection points. ll connections shall provide direct contact of current-carrying parts and shall not depend on current transfer through fastener thread-to-thread contact. s and their blown-fuse indicators shall be visible (when the transformer compartment door(s) are open) without removal of the clear-polycarbonate door safety barrier to allow easy identification of blown fuses without de-energizing or removing the fuse from service. Electrical components shall be air-insulated and positioned to allow visual inspection of all internal connections and components without removing the clear-polycarbonate door safety barrier, de-energizing or removing the equipment from service. lternate 1: mountings shall be Code to accept 1. amp to 100 amp (max), Eaton s Cooper Power Systems NX and amp to 10 amp (max), Eaton s Cooper Power Systems X-Limiter TM clip-mounted current-limiting fuses. When 1. amp to 0 amp Code fuses are supplied, one Industries #3901-CM- fuse extender per fuse shall be supplied to extend the Code fuse length to fit Code fuse mountings. Warning Sign, #7201-W , shall be provided inside the transformer compartment door(s) to warn the operator to Park the load side cable before installing or removing fuses. Danger Sign, #7203-D , shall be provided in a prominent location near the fuse clips to warn the operator Do not remove fuse under load. lternate 2: mountings shall be Code to accept 1. amp to 100 amp (max), 1. kv Eaton s Cooper Power Systems NX and amp to 12 amp (max), 1. kv Eaton s Cooper Power Systems X-Limiter TM clip-mounted current-limiting fuses. When 1. amp to 0 amp 1. kv Code fuses are supplied, one Industries #3901-CM- fuse extender per fuse shall be supplied to extend the Code fuse length to fit Code fuse mountings. Warning Sign, #7201-W , shall be provided inside the transformer compartment door to warn the operator to Park the load side cable before installing or removing fuses. Danger Sign, #7203-D , shall be provided in a prominent location near the fuse clips to warn the operator Do not remove fuse under load. arriers Phase and ground barriers shall be provided to assure correct phase-to-phase and phase-to-ground clearances for proper operation at rated voltage. These barriers shall be glass-reinforced polyester (NEM GPO-3 class material) not less than inch thick. removable insulating barrier with a DNGER Keep Out! Hazardous voltage sign, #7203-D , shall be located inside the door(s) on the transformer compartment as recommended in Rule 381G of IEEE Standard C2 (National Electrical Safety Code). When the enclosure width exceeds 7 inches, the removable insulating barrier shall be divided to provide sectional door safety barriers with reduced size for secure handling. The door safety barrier(s) shall be constructed of 0.2-inch clear-polycarbonate (Lexan or equal) and shall completely close the door opening and be provided with a nonconductive safety latch requiring a positive action to remove the barrier. Handles and other hardware extending through this door safety barrier shall be nonconductive material. Handles shall be keyed to prevent rotation for secure handling. Complete visual inspection of the internal components shall be possible without removing the door safety barrier. Grounding Provisions Four high-conductivity bronze eyebolt-type ground lugs, which accept # through #2/0 copper conductor, Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

16 1-kV Safefront 00 mp ulletin 0-10 Page Specification - Page 3 of 3 shall be installed two in the cable terminating compartment and two in the transformer compartment on each side of the door opening in an accessible position (as shown on the drawings). ccessory Equipment Stainless steel parking stands shall be provided in the quantity required to allow use of feed-thru bushings, parking bushings and grounding bushings. The parking stands shall be welded in place, in a position to allow the use of hot-line tools for installation of feed-thru bushings, etc. The parking stands shall be unpainted (except welds shall be painted) to provide a ground for feed-thru bushings and other devices that may be placed into the parking stands. corrosion proof nameplate with permanent thermal transfer printing shall be installed inside one door on the elbow compartment. It shall be located at the top corner farthest from the elbows when the door is open. The nameplate will provide Type of Equipment, Model Number, mps Continuous, kv imum, IL, Serial Number, Job Number, Date Manufactured and Weight of Equipment. us, fuse and transformer connections between bushings shall be displayed (on the cable side of the equipment plate) using 0.-inch-wide solid orange-color pressure-sensitive vinyl tape and die-cut orange-color pressure-sensitive vinyl fuse symbols not less than 2. inches high. The resulting schematic shall clearly indicate the circuit arrangement of the transformer station. The schematic shall be legible at a distance of six feet or more. When enclosures have more than one door (or other access provision) each access shall be labeled in near proximity of the locking provisions with a pressuresensitive vinyl label using letters not less than 0.37-inch nor more than 0.2-inch high. The label shall indicate the type of equipment behind the access (elbows, fuses, bus, etc.). When specified, four anchor-bolt brackets, # or approved equal, shall be supplied with each transformer station to provide a means of clamping the equipment to the concrete pad. Packaging Each transformer station shall be bolted to a solid-top wood pallet (to prevent the forks of a forklift truck from entering the open bottom of the equipment) to prevent hidden damage. The equipment shall be wrapped with 0.12-inch thick polyethylene foam or other suitable material to minimize damage to the finish during shipment. Drawings When specified, drawings shall be furnished for each transformer station that include: 1) enclosure dimensions and location of components. 2) proposed cable-training layout and dimensions. 3) proposed pad dimensions and location of anchor bolts. See ulletin for 1-kV Safefront 200 mp s Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

17 1-kV Safefront 00 mp ulletin 0-10 Page ushing Installation Instructions The primary transformer stations shown in this bulletin have equipment plates punched to accept six bushings. When you purchase a primary transformer station requiring less than six bushings, the extra mounting holes are closed with "bushing-style" insulators or adapter plates. If circuit requirements change, bushings can be added or removed to provide any of the circuit arrangements shown in this bulletin. The mounting hardware used to mount the "bushing-style" insulators or adapter plate is the same hardware used to install a bushing. There is no need to drill holes when modification is required. NOTE: The primary transformer station must be de-energized and grounded in accordance with your company's normal safety procedure before any modifications are made. Procedure for ushing Installation NOTE: The shipping cap on the bushing should be left in place to prevent contamination of the interface. 1. Remove the bolt that fastens the bus bar to the "bushing-style" insulator. 2. On the opposite end of the bus bar, loosen the bolt that fastens the bus bar to the bushing. The bus bar will then drop down so the "bushing-style" insulator or adapter plate assembly can be easily removed. 3. Remove the "bushing-style" insulator or adapter plate assembly from the equipment plate (retain for future use).. Install the bushing into the mounting hole from the transformer side.. Install the serrated-flange bolts. olts should be tightened in a uniform manner applying no more than 90 inch-pounds torque to each bolt. The serrated-flange bolts must "cut" into the mounting plate to provide a connection from the shielding to the grounded mounting plate.. Connect the copper bus bar to the bushing just installed using hardware previously removed. 7. Tighten bolt on both ends of bus bar no more than 88 foot-pounds. IMPORTNT: Do not energize this bushing with only the shipping cap in place. To do so would lead to failure of the bushing and create a hazard to operating personnel. This product is designed to be used only when it is mated with an appropriate 00 mp, 1 kv or 2 kv class elbow conforming to the latest revision of IEEE Standard 38. The elbow should be installed in accordance with the instructions supplied by the elbow manufacturer. Uni-Mount Holes Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

18 1-kV Safefront 00 mp ulletin 0-10 Page mp ushing # Four x 1 Inserts Dia. Tin-Plated luminum Conductor Tapped x 1.2 Deep (both ends of conductor) mp Deadbreak Interface No and 2 kv class per IEEE Standard Conductive Shielding Voltage Class... 2 kv Leakage Distance, Inches...3 Phase-to-Ground Voltage kv Dry rcing Distance, Inches...8. IL kv Mechanical - Strength Rating, Pounds C Withstand - 1 Min. Dry... 0 kv Cantilever, Ultimate 2. inches past end...>1, Sec. Dew... 0 kv Tensile, Pounds...>,000 DC Withstand - 1 Min. Dry kv Torsion, Inch-Pounds (bolt breaks)...>3,00 Corona Extinction Level - Minimum kv Compression, Pounds...20,000 Continuous Current mps Insert Thread Size " 1 x 1" Momentary - RMS, Sym., 0.17 sec... 2,000 mps Conductor (live end) Thread Size x 1. RMS, Sym., 3 sec... 10,000 mps Net Weight, Pounds (kg) (3.8) Specifications - 00 mp 1-kV and 2-kV ushings ushings shall be 00 ampere # , 2 kv class (1.2 kv to ground) ir-insulated ushings, 12 kv IL, per IEEE Standard Fig. 13 (Interface 11: a 00 and 900 deadbreak interface, 1 and 2 kv class) for use with either 8.3/1. kv or 1.2/2.3 kv separable insulated connectors (Elastimold, Eaton s Cooper Power Systems or other approved equal). The bushings shall be pressuremolded cycloaliphatic epoxy with a 1.2-inch diameter tin-plated aluminum conductor on the air-insulated side that is drilled and tapped 0.2-inch 11UNC x 1-inch deep to provide direct connection of the bus and/or live parts. Leakage distance from the apparatus connection end of the bushing to ground shall be not less than 30 inches to assure trouble-free operation in a wet and/or contaminated environment. Integral shielding shall be provided to eliminate partial discharge caused by off-center mounting and mounting holes that may have sharp edges or burrs. ushings shall mount in a 3.12-inch diameter opening and bolt in place to allow field replacement with standard tools. The bushing mounting bolts shall be self-locking stainless steel serrated-flange hex-head bolts that cut through the enclosure protective finish to ground the integral shielding of each bushing. To assure adequate strength for apparatus support, the bushing shall withstand a minimum cantilever loading of 00 pounds for five minutes without damage. The bushing interface shall be free of all voids, holes and heat sinks to assure proper mating with separable insulated connectors. Each bushing shall be tested in free air, mounted in a grounded steel plate not less than 10 inches x 10 inches, with an insulated protective cap (Eaton s Cooper Power Systems #DPC2 or equal) installed on the interface to accurately simulate operating conditions (gas or liquid dielectric on the interface shall not be acceptable for this test). Each bushing shall meet the requirements for 2 kv devices in accordance with the test values of IEEE Standard 38 (latest revision), including 100 percent production testing. Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

19 1-kV Safefront 00 mp ulletin 0-10 Page Selection Information NX Current-Limiting s Clip-Mounted Style Upper Contact Catalog No CM- CM- CM- High-temperatureresistant Tubing Rating Information Lower Contact Indicator utton (hidden) Eaton s Cooper Power Systems Type NX Current-Limiting lown-fuse Indicator utton Features Silent - No gases are expelled because the arc is confined and cooled and the vapor quickly condensed by a sand filler. Safe - No explosion or strong mechanical force is produced to damage surrounding equipment; no burning particles that might be a fire hazard. Current-limiting - Fault current is held to a low value by a fulgurite produced by the fault current itself. Compact - NX fuses require less operating clearance than expulsion fuses. variety of space-saving schemes are available with fuse mountings. Fast, full-range clearing from minimum melt to maximum fuse rating. NX fuses clear faults in one-half cycle or less at high-fault currents. Positive, accurate time-current coordination with other protective devices in the line. lown-fuse indication - red button in the end of the lower contact projects and is visible after the fuse has operated. Two NX fuses can be paralleled for higher capacity. Design enables fuses to handle high energy when clearing faults in parallel. Voltage (kv) ,000 amps Symmetrical Interrupting Rating Rating Continuous Current (amp) Code Number* For Single and Parallel Unit Clip-Style s Catalog Number F3H1 F3H3 F3H F3H F3H8 F3H10 F3H12 F3H18 F3H20 F3H2 F3H30 F3H0 F3H0 F3H F3H80 F3H100 FH1 FH3 FH FH FH8 FH10 FH12 FH18 FH20 FH2 FH30 FH0 FH0 FH FH80 FH100 *Code number of mounting must match code number of fuse or switchblade. t present, 100 amp, 1. kv fuse is suitable for systems up to 13. kv maximum voltage rating. extenders must be used to extend 1. to 0 amp fuses so they fit the 100 amp fuse mountings in Safefront s. Extends Code To Fit Mfg. Code For other combinations see ulletin 3901 Installation is easy using two adjustable wrenches. The fuse extender is pushed onto the top contact of the fuse and the compression nut is tightened. To remove the extender, loosen the compression nut and pull the extender off. Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

20 1-kV Safefront 00 mp ulletin 0-10 Page Selection Information X-Limiter TM Current-Limiting s Clip-Mounted Style Indicator utton (hidden) Upper Contact Catalog No CM- CM- CM- High-temperatureresistant Tubing Rating Information Lower Contact lown-fuse Indicator utton Eaton s Cooper Power Systems X-Limiter TM Full-Range Current-Limiting Features Unique "Power " Coordination Characteristics Full-Range Current Clearing Voltage (kv) ,000 amps Symmetrical Interrupting Rating Rating Continuous Current (amp) Code Number* For Single and Parallel Unit Clip-Style s Catalog Number 83F0-I/I 83F08-I/I 83F10-I/I 83F12-I/I 83F18-I/I 83F20-I/I 83F2-I/I 83F30-I/I 83F0-I/I 83F0-I/I 83F-I/I 83F80-I/I 83F100-I/I 83F12-I/I 83F10-I/I 1F0-I/I 1F08-I/I 1F10-I/I 1F12-I/I 1F18-I/I 1F20-I/I 1F2-I/I 1F30-I/I 1F0-I/I 1F0-I/I 1F-I/I 1F80-I/I 1F100-I/I 1F12-I/I *Code number of mounting must match code number of fuse or switchblade. vailable for Indoor and Outdoor Silent, Non-Expulsive Operation Field-Proven Silver Element To omit Optional lown Indicator delete "/I" Interchangeable with Industry Standard Codes,, and 9 extenders must be used to extend 1. to 0 amp fuses so they fit the 100 amp fuse mountings in Safefront s. Extends Code To Fit Mfg. Code For other combinations see ulletin 3901 Installation is easy using two adjustable wrenches. The fuse extender is pushed onto the top contact of the fuse and the compression nut is tightened. To remove the extender, loosen the compression nut and pull the extender off. Elastimold is a registered trademark of sea rown overi Ltd. Industries, Inc. 109 Hamilton Road ossier City, LoUiSina sales@elliott-industries.com Copyright 2018 Phone Fax

15-kV Safefront 200 Amp Primary Transformer Station Pad-Mounted Outdoor

15-kV Safefront 200 Amp Primary Transformer Station Pad-Mounted Outdoor 1-kV Safefront 200 mp ulletin 0-102 Page 1 2018 200 mp Elliott air-insulated bushing wells accept IEEE Standard inserts and elbows Open bottom and extra depth of elbow compartment provides space for use

More information

15-kV Safefront 200 Amp Source Isolated Cable Switching Station Pad-Mounted Non-Fusible

15-kV Safefront 200 Amp Source Isolated Cable Switching Station Pad-Mounted Non-Fusible ulletin Page 208 -gauge steel equipment plate is rigid for easier elbow operation Heavy-duty -gauge steel enclosure is all-welded construction for long life "Elbows" compartment label is visible with doors

More information

25-kV Safefront Mini-Switch Phase Isolated Pad-Mounted Switchgear 125 Amp (Max) Clip-Mounted Current-Limiting Fuses

25-kV Safefront Mini-Switch Phase Isolated Pad-Mounted Switchgear 125 Amp (Max) Clip-Mounted Current-Limiting Fuses ulletin Page 1 2018 11-gauge steel equipment plate is rigid for easier elbow operation Heavy-duty 11-gauge steel enclosure is all-welded construction for long life us and fuse schematic is orange-colored

More information

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses Page 1 2016 EPMR-35-311S-R2/ESW-CM9 Three Phase Two Ways per Phase 200 Amp 35 kv Class Eaton s CPS LRTPs 50 Amp (Max) 27 kv Clip-Mounted NX Fuse Provisions 21.1/36.6 kv Grounded Wye Max Design, 150 kv

More information

15-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 140 Amp (Max) Clip-Mounted Current-Limiting Fuses

15-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 140 Amp (Max) Clip-Mounted Current-Limiting Fuses Page 1 2016 Heavy duty 11-gauge steel enclosure is all-welded construction for long life 200 Amp Elliott air-insulated bushing wells accept IEEE Standard inserts and elbows ushing wells may be added or

More information

15-kV Live Terminal Primary Metering Station Pad-Mounted Outdoor

15-kV Live Terminal Primary Metering Station Pad-Mounted Outdoor ulletin Page 1 2015 Cross-kinked roof prevents standing moisture Metering Transformer compartment label is visible with doors closed Heavy duty 11-gauge steel enclosure is all-welded construction for long

More information

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch Page 1 2015 Kinked roof prevents standing moisture Glass reinforced barriers meet NEMA GPO-3 Standards 0.625" diameter copper ground bar Elliott air-insulated bushings accept IEEE Standard inserts and

More information

35-kV Safefront 200 Amp Primary Metering Station Pad-Mounted Outdoor

35-kV Safefront 200 Amp Primary Metering Station Pad-Mounted Outdoor ulletin Page 1 2016 Heavy duty 11-gauge steel enclosure is all-welded construction for long life 11-gauge steel equipment plate is rigid for easier elbow operation Upper parking stands extend 3" per IEEE

More information

35-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current-Limiting Fuses

35-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current-Limiting Fuses Page 1 2016 Heavy duty 11-gauge steel enclosure is all-welded construction for long life 11-gauge steel equipment plate is rigid for easier elbow operation Parking stands for the upper two phases extend

More information

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor 35-kV Safefront 2 Amp SuperWell 5-33 Page 1 216 EPM-PMS-35-311P-R2/ESW Three Phase Two Ways per Phase 2 Amp 35 kv Class Eaton's CPS LRTPs NEMA Standard Outdoor Instrument Transformer Provisions 21.1/36.6

More information

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses Page 1 2015 Heavy duty 11-gauge steel enclosure is all-welded construction for long life Corrosion proof nameplate is located to provide easy access for the operator Glass reinforced barriers meet NEMA

More information

Bus and fuse schematic is orange-colored vinyl for high visibility

Bus and fuse schematic is orange-colored vinyl for high visibility -kv Safefront Mini-Switch 0 mp (Max) s and 0 mp (Max) s ulletin 00-0 Page 208 -gauge steel equipment plate is rigid for easier elbow operation Heavy-duty -gauge steel enclosure is all-welded construction

More information

15-kV Live Terminal 200 Amp Mini-Switch Source-Isolated Pad-Mounted Switchgear 40 Amp (Max) Arc-Strangler NX Fuses

15-kV Live Terminal 200 Amp Mini-Switch Source-Isolated Pad-Mounted Switchgear 40 Amp (Max) Arc-Strangler NX Fuses Page 1 2015 Heavy duty 11-gauge steel enclosure is all-welded construction for long life Door safety barrier removal instructions Safety latches on the door safety barriers, front and rear, are insulating

More information

15-kV Safefront 200 Amp Primary Capacitor Station Pad-Mounted Outdoor

15-kV Safefront 200 Amp Primary Capacitor Station Pad-Mounted Outdoor Page 1 2015 Heavy-duty 11-gauge steel enclosure is all-welded construction for long life Clear polycarbonate removable safety barrier separates upper and lower compartment (supplied only with internally

More information

35-kV Safefront 200 Amp SuperWell Primary Capacitor Station Pad-Mounted Outdoor

35-kV Safefront 200 Amp SuperWell Primary Capacitor Station Pad-Mounted Outdoor Page 1 2016 EPM-PCS-35-320P-R2/ESW-GCM6-2S-SA Three Phase Two Ways per Phase 200 Amp 35 kv Class Eaton's CPS LRTPs 35 kv Elliott Air-Insulated SuperWell Bushings 21.1/36.6 kv Grounded Wye Max Design, 150

More information

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 35 kv Separable Insulated Connector (elbow) Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other

More information

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 15 kv or 25 kv Separable Insulated Connector (elbow) Equipment Connection Power Cable Power Cable ELRIM Cycloaliphatic

More information

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection 35 kv Separable Insulated Connector (elbow) Bus Bar or Other Component Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other

More information

25 kv Apparatus Bushings

25 kv Apparatus Bushings Page 1 2001 ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric strength, dielectric loss and power factor Choice of shapes allows design innovation

More information

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection 15 kv or 25 kv Separable Insulated Connector (elbow) Grounded Metal Equipment Plate Equipment Connection Power Cable Power Cable ELRIM Cycloaliphatic

More information

15 kv and 25 kv Thru-Bushings

15 kv and 25 kv Thru-Bushings Page 1 2001 ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric strength, dielectric loss and power factor Choice of shapes allows design innovation

More information

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Equipment Connection Bus Bar, or Grounded Metal Equipment Plate F Series Mounting Holes ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric

More information

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break Part 1-GENERAL 1.1 DESCRIPTION Guide Specification Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break The switchgear shall consist of magnetically actuated solid dielectric insulated

More information

ME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv

ME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv ME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv ABB ME series fused sectionalizing enclosures ABB's dead-front Padmount ME series

More information

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT PADMOUNTED SWITCHGEAR WITH VACUUM LOAD

More information

S&C Manual PME Pad-Mounted Gear

S&C Manual PME Pad-Mounted Gear S&C Manual PME Pad-Mounted Gear Outdoor Distribution,. kv and 5 kv S&C Manual PME Pad-Mounted Gear... Featuring Elbow-Connected Encased Components. S&C Manual PME Pad-Mounted Gear brings in-air insulation,

More information

SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed.

SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed. City of Cartersville Electric System P.O. Box 1390 320 S. Erwin St. Cartersville, GA 30120 770-387-5631 March 2006 SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS This specification provides standardization

More information

Typical Specification

Typical Specification Engineered to Order Built to Last Typical Specification VAULT VRPFI, TWO POSITION, ROTARY PUFFER SWITCHGEAR PART 1- GENERAL 1.1 DESCRIPTION A. The switch shall consist of manually operated load interrupting,

More information

Product Specifications for Phase Over Phase GOABS(r)

Product Specifications for Phase Over Phase GOABS(r) 1. General a) This specification covers the design, manufacture, and shipment of phase-over-phase, 1-way, 2-way, 3-way, and 4-way, gang-operated disconnecting switches, both air-break and load-break, for

More information

Underground Distribution Switchgear

Underground Distribution Switchgear Underground Distribution Switchgear Functional Specification Guide Functional Specification for 15 kv, 25 kv, or 35 kv Underground Distribution Switchgear 1. Scope 1.1. This specification applies to three-phase,

More information

SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES

SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT SUBMERSIBLE AND VAULT MOUNTED

More information

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application The most advanced Arc-Resistant Switchgear, designed and built to provide maximum safety in the event of an Internal Arcing Fault. 5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application Page 1

More information

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 1. APPLICATION A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 2. REFERENCE STANDARDS A. The transformers supplied shall

More information

STANDARD SPECIFICATION FOR TYPE PLD LIVE-FRONT/DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV A. General

STANDARD SPECIFICATION FOR TYPE PLD LIVE-FRONT/DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV A. General Page 1 STANDARD SPECIFICATION FOR TYPE PLD LIVE-FRONT/DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV A. General 1. Product The pad-mounted switchgear shall be in accordance with the applicable plans, drawings,

More information

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings Page 1 Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings I. General This specification covers the design requirements for a pad-mounted capacitor

More information

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak Powergrid Solution s Metal Enclosed Switchgear has many different customizable options and configurations. Customers

More information

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER Solid Dielectric Load Break Switch SPECIFICATION 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT PADMOUNTED VACUUM LOAD INTERRUPTING

More information

100 / 110 DRYWELL FUSE SPECIFICATION

100 / 110 DRYWELL FUSE SPECIFICATION 100 / 110 DRYWELL FUSE SPECIFICATION 15KV & 25KV SUBMERSIBLE VACUUM LOAD INTERRUPTERS AND DRYWELL FUSE ASSEMBLIES MANUALLY OPERATED / REMOTELY OPERATED SUBMERSIBLE SWITCHGEAR WITH LOAD INTERRUPTING SWITCHES

More information

GE 8000-Line Motor Control Centers

GE 8000-Line Motor Control Centers GE 8000-Line -1 ENCLOSURE TYPES TYPE 1 General Purpose, Indoor Intended for use indoors, primarily to prevent accidental contact of personnel with the enclosed equipment, in areas where unusual service

More information

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised

More information

Underground Distribution Switchgear

Underground Distribution Switchgear Underground Distribution Switchgear Functional Specification Guide Functional Specification for 15 kv, 25 kv, or 35 kv Underground Distribution Switchgear 1. Scope 1.1. This specification applies to three-phase,

More information

Product Specifications for Aluminum Vertical Break Switches

Product Specifications for Aluminum Vertical Break Switches 1. General a) This specification covers the design, manufacture, and shipment of aluminum vertical break switches, both air-break and load-break configurations, for substation and transmission switching

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV

DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV TYPE PSE MANUAL DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV Figure 1 Federal Pacific Dead-Front PSE (available as UL Listed) contains an integrated system of fuses and switches with access control features

More information

STANDARD SPECIFICATION FOR LIVE-FRONT 15KV AND 25KV PSI/II PAD-MOUNTED SWITCHGEAR

STANDARD SPECIFICATION FOR LIVE-FRONT 15KV AND 25KV PSI/II PAD-MOUNTED SWITCHGEAR STANDARD SPECIFICATION FOR LIVE-FRONT 15KV AND 25KV PSI/II PAD-MOUNTED SWITCHGEAR A. General 1. Product The pad-mounted switchgear shall be PSI/II design as manufactured by Federal Pacific and shall conform

More information

STANDARD SPECIFICATION FOR PAD-MOUNTED CAPACITOR BANKS FOR 15kV or 25kV APPLICATIONS

STANDARD SPECIFICATION FOR PAD-MOUNTED CAPACITOR BANKS FOR 15kV or 25kV APPLICATIONS A. General 1. Product The pad-mounted capacitor banks shall be in accordance with the applicable plans, drawings, and one-line diagrams and shall conform to these specifications. 2. Assembly The outdoor

More information

Type MOST oil switch

Type MOST oil switch Underground Distribution witchgear CA285002EN Effective October 20 upersedes 285-20 October 2013 COOPER POWER ERIE ype MO oil switch Contents Description Page General...2 Ordering information....2 Features

More information

Technical Specification For Outdoor Substation Harmonic Filter Banks

Technical Specification For Outdoor Substation Harmonic Filter Banks Technical Specification For Outdoor Substation Harmonic Filter Banks One of Three 5th, 11th & 23rd, 34.5 kv, Rated Harmonic Filter Assemblies Provided for a Central Venezuela Heavy Oil Production Field

More information

MATERIAL SPECIFICATION ELECTRIC OPERATIONS ORGANIZATION. M3902 ****Supercedes BECo Standard E and ComElectric Spec ****

MATERIAL SPECIFICATION ELECTRIC OPERATIONS ORGANIZATION. M3902 ****Supercedes BECo Standard E and ComElectric Spec **** Page 1 of 8 ****Supercedes BECo Standard E2.12-2.12 and ComElectric Spec 6-0895**** 1.0 General Requirements SINGLE PHASE PAD-MOUNTED DISTRIBUTION TRANSFORMERS 1.1 These specifications cover single-phase

More information

C1000 Series Automatic Cap Bank

C1000 Series Automatic Cap Bank C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution

More information

Submersible Vacuum Fault Interrupters

Submersible Vacuum Fault Interrupters Submersible Vacuum Fault Interrupters UG Distribution Medium Voltage Vacuum Fault Interrupters Functional Specification Guide PS024002EN Functional Specification for 2.4kV to 17.5kV UG Distribution Medium

More information

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B

CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B CENTER BREAK GROUP OPERATED AIR BREAK SWITCHES RATED 15.5kV THROUGH 170kV EFFECTIVE DATE: 10/25/16 REV B TCV2 Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com

More information

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115 CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115 PADMOUNTED TRANSFORMERS 12kV AND DUAL VOLTAGE, RADIAL FEED STAINLESS STEEL NOVEMBER 2011 Specification:ELE_115_R1 Page

More information

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein. 16425 SWITCHBOARD ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 24 13 An optional keynote to

More information

Three-Phase Pole Mounted Recloser

Three-Phase Pole Mounted Recloser Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE

More information

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications Descriptive bulletin Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications General overview Reliable, low maintenance and economical Load Interrupter

More information

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale S&C Omni-Rupter Switches Outdoor istribution (14.4 kv and 5 kv) Specifications Conditions of Sale STNR: Seller s standard conditions of sale as set forth in Price Sheet apply. SPECIL TO THIS PROUCT: INCLUSIONS:

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34. S&C Power Fuses s SM and SMLa Indoor Distribution (4.16 through 34. ) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set

More information

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum PAGE 1 OF 5 USE: 1. For commercial and industrial installations purchased and installed by the Customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase

More information

Automatic, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

Automatic, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification Automatic, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification 1. General 1.1 This specification is for an automatic, medium-voltage, padmounted, three-phase power capacitor

More information

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV Cutler Hammer SECTION PB-1A-110 PAGE 1 Replaces April, 1996 TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV The PSI/II Padmount is the second generation of switchgear in the PSI switchgear family. The PSI/II

More information

MEH Series Sectionalizing Enclosures. Single-Phase and Three-Phase

MEH Series Sectionalizing Enclosures. Single-Phase and Three-Phase MEH Series Sectionalizing Enclosures Single-Phase and Three-Phase ABB MEH Sectionalizing Enclosures ABB s MEH Sectionalizing Enclosures provide an economical and safe sectionalizing tap point for underground

More information

Fixed, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

Fixed, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification Fixed, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification 1. General 1.1 This specification is for a fixed, medium-voltage, padmounted, three-phase power capacitor bank

More information

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum

CABINET - CURRENT TRANSFORMER Indoor - Outdoor 240 Volts Amperes Maximum PAGE 1 OF 5 USE: 1. For commercial and industrial installations, purchased and installed by customer. 2. For use on the following services: 1 phase 3 wire 240 volts, 3 phase 3 wire 240 volts, 3 phase 4

More information

Technical Specification for Pole Mounted Capacitor Rack

Technical Specification for Pole Mounted Capacitor Rack Technical Specification for Pole Mounted Rack Page 1 1. Scope and Function a) Pole mounted capacitor racks shall be installed on a distribution feed as an economical means of applying capacitor units to

More information

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv) S&C Power Fuses Types SM- 4, SM-5, SMD-0, and SMD-40 Outdoor Distribution (4.16 kv through kv) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: The seller s standard

More information

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet apply, except as modified under

More information

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z PART 1 GENERAL 1.01 1.02 1.03 1.04 1.05 SCOPE The Contractor shall furnish and install fixed power factor correction equipment as specified herein and as shown on the contract drawings. This specification

More information

600 A 15 and 25 kv class Cleer grounding elbow

600 A 15 and 25 kv class Cleer grounding elbow Loadbreak/Deadbreak Connectors CA650013EN Supersedes March 2015 COOPER POWER SERIES 600 A 15 and 25 kv class Cleer grounding elbow General Eaton provides a visible ground on its Cooper Power series 600

More information

AMENDMENT ELECTRIC SERVICE MANUAL 2014

AMENDMENT ELECTRIC SERVICE MANUAL 2014 AMENDMENT (Pages 20,43,50,72,74,,76,78,83,86,99) ELECTRIC SERVICE MANUAL 2014 Effective April 1, 2015 18-7 6.0 SERVICE AND SERVICE ENTRANCES (General), Continued Conductor Sizing It is recommended that

More information

D-73P disconnect and bypass switches

D-73P disconnect and bypass switches Switches atalog Data 008005EN Supersedes pril 2016 OOPER POWER SERIES D-73P disconnect and bypass switches ontents Description Page D-73P disconnect switch....2 D-73P3 bypass switch....5 D-73P-D cutout

More information

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised

More information

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv) Outdoor Distribution (4.4 kv through 46 kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 50 apply, except as modified under WARRANTY QUALIFICATIONS

More information

NX indoor current-limiting fuses

NX indoor current-limiting fuses Fusing Equipment Catalog Data CA132049EN Supersedes 240-60 September 2009 COOPER POWER SERIES NX indoor current-limiting fuses General Eaton provides overload protection for all indoor and underground

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

Disconnect & ByPass Switches

Disconnect & ByPass Switches Disconnect & ByPass Switches Disconnect & Oil Circuit Recloser Bypass Switches; Regulator & Current Transformer Bypass Switches Electrical Apparatus K-SEC 060 & 090 Contents Type D-73 Distribution Class

More information

SPECIFICATION BULLETIN

SPECIFICATION BULLETIN SPECIFICATIONS Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified under WARRANTY QUALIFICATIONS on page 3. SPECIAL TO THIS PRODUCT:

More information

ELF -LR current-limiting fuse

ELF -LR current-limiting fuse Fusing Equipment Catalog Data C132044EN Supersedes 240-71 ugust 2006 COOPER POWER SERIES ELF -LR current-limiting fuse General Eaton's Cooper Power series ELF -LR currentlimiting fuse is a full range current-limiting

More information

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position LET S BE PACIFIC November 0 Volume Number 5 ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position Federal Pacific has the capability to engineer, fabricate and assemble

More information

Solid Dielectric, Single Phase Recloser

Solid Dielectric, Single Phase Recloser Solid Dielectric, Single Phase Recloser Catalog O-vsp17 Viper-SP Viper-SP solid dielectric, single phase recloser combines the time-proven reliability of electronically controlled, vacuum fault interrupters

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

INDEX Welcome 1.2 Contacting Powergrid Solutions, Inc. 1.3 Terms Of Usage 1.4 Product Codes and Descriptions

INDEX Welcome 1.2 Contacting Powergrid Solutions, Inc. 1.3 Terms Of Usage 1.4 Product Codes and Descriptions INDEX SECTION 1 INTRODUCTION 1.1 Welcome 1.2 Contacting Powergrid Solutions, Inc. 1.3 Terms Of Usage 1.4 Product Codes and Descriptions SECTION 2 PADMOUNTED ENCLOSURES/CABLE SWITCHING/TERMINATING GEAR

More information

Product Selection Guide

Product Selection Guide Oil-Submersible Backup Fuses Full-Range CL Fuses External Backup Fuses Molded Fuse Products Product Selection Guide Introduction Electric distribution systems demand high levels of reliability, and flexibility

More information

600 A 15 kv class T-OP II deadbreak connector

600 A 15 kv class T-OP II deadbreak connector Deadbreak Apparatus Connectors CA650017EN Supersedes 600-12 February 2010 COOPER POWER SERIES 600 A 15 kv class T-OP II deadbreak connector General Eaton terminates high-voltage underground cable to transformers,

More information

PAD-MOUNT SWITCHGEAR 15kV 25kV 35kV

PAD-MOUNT SWITCHGEAR 15kV 25kV 35kV PAGE 1 TYPE PSI PAD-MOUNT SWITCHGEAR 15kV 25kV 35kV INSTRUCTIONS For Installation and Operation INTRODUCTION... 1 Receiving... 1 Handling... 1 Storage... 1 GENERAL DESCRIPTION... 1 SAFETY FEATURES... 1

More information

MATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec ****

MATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec **** Page 1 of 8 ****Supercedes BECo Standard E2.12-2.14 and ComElectric Spec 7-0895**** THREE-PHASE DEADFRONT PAD-MOUNTED DISTRIBUTION TRANSFORMERS, LOOP & RADIAL FEED DESIGNS 1.0 General Requirements 1.1

More information

10 Commercial, Industrial, Agricultural Services

10 Commercial, Industrial, Agricultural Services 10 Commercial, Industrial, Agricultural Services This section describes the Power Company requirements for commercial, industrial, and agricultural services. This section covers single phase and three

More information

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL

Deadbreak Apparatus. connectors. 600 A 15/25 kv Class GENERAL Deadbreak Apparatus Connectors 600 A 15/25 kv Class BOL-T Deadbreak Connector Electrical Apparatus 600-30 GENERAL The Cooper Power Systems 600 A, 15/25 kv Class BOL-T Deadbreak Connector is used to terminate

More information

X-Limiter full-range current-limiting fuse

X-Limiter full-range current-limiting fuse Fusing Equipment Catalog Data CA132050EN Supersedes 240-56 June 2012 COOPER POWER SERIES X-Limiter full-range current-limiting fuse General Eaton's Cooper Power series X-Limiter full-range current-limiting

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim Applications The CDP panels provide protection for lightning and power distribution circuits in the commercial and industrial establishments. The circuit breakers thermomagnetic trip allows for momentary

More information

Type EB, EBB, EBF and VEB DOUBLE SIDE BREAK SWITCHES 38 kv through 362 kv 600 to 3000 Ampere

Type EB, EBB, EBF and VEB DOUBLE SIDE BREAK SWITCHES 38 kv through 362 kv 600 to 3000 Ampere Type EB, EBB, EBF and VEB DOUBLE SIDE BREK SWITCHES 8 kv through 62 kv 600 to 000 mpere TYPE EB 1 Morpac Industries, Inc. 2725 East Ginter Road Tucson, rizona 85706 520-294-452 FX 520-294-2 Type EB, EBB

More information

INSTALLATION PRODUCTION TESTS

INSTALLATION PRODUCTION TESTS Deadbreak Apparatus Connectors 600 A 15/25 kv Class Bol-T Deadbreak Connector Electrical Apparatus 600-10 GENERAL The Cooper Power Systems 600 A, 15/25 kv Class Bol-T Deadbreak Connector is used to terminate

More information

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5 PAGE 1 OF 5 USE: Requirements for entrance equipment. PREVIOUS REVISION 07-01-98 ORIGINATED 03-94 PREVIOUS NUMBER ER 100 (12-01-81) LATEST REVISION: Updated meter socket labeling specification and instrument

More information

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide 1ZSC563-AAA en, Rev. 6 Resin impregnated paper bushing, oil to SF 6, type GSBK Technical guide Original instruction The information provided in this document is intended to be general and does not cover

More information

Grounding equipment COOPER POWER SERIES. Temporary Connections CA325004EN. Contents

Grounding equipment COOPER POWER SERIES. Temporary Connections CA325004EN. Contents Temporary Connections CA325004EN Supersedes November 2016 Grounding equipment COOPER POWER SERIES Contents Description Page Grounding elbow products... 2 Grounding elbow and kit product ratings... 5 200

More information

RBA Catalog Numbers and Information

RBA Catalog Numbers and Information 50 RBA s and Information Type RBA Expulsion Fuses for Use Indoors or in an Enclosure Ampere Rating Standard Speed (Fuse Refills) Curve Reference 36-635 Time-Lag (Fuse Refills) Curve Reference 36-635 Approx.

More information

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV) SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information