1 MANUAL Con-Evator Serial No... ISO GB Rev. 03 June 2009

2 Rev. 03 Con-Evator Page CONTENS 2.0 GENERAL INFORMATION Application Restrictions Design Operating principles Certificates TECHNICAL DATA Technical specifications Typeplate Dimensioned drawings Capacity table Noise level ASSEMBLY /DISASSEMBLY Assembly Disassembly Electric connection Control Operation Start Operation Stop ACCESSORIES List of accessories Connecting and installing accessories MAINTENANCE - SVR Maintaining the air filter and the base filter Maintaining the bottom flap SVR (stainless steel) Adjustment of the magnetic switch TROUBLESHOOTING The Con-Evator does not start The Con-Evator capacity has been reduced The Con-Evator stops at short intervals REPAIRS Replacement of fuse for control voltage Replacement of bottom flap SVR (stainless steel)... 30

3 Rev. 03 Con-Evator Page 2 NB! All electrical diagrams can be found in the pocket in the back of the manual

4 Rev. 03 Con-Evator Page GENERAL INFORMATION 2.1 Application The Con-Evator SVR is a vacuum hopper loader designed for conveying of free-flowing granular plastic material from a bag or bin to the intermediate hopper of the processing machine or another hopper. 2.2 Restrictions The SVR unit may only be used for the purposes specified. The SVR unit can be used neither for powders (only in special version) or liquids, nor for living creatures. The SVR unit must be used by a qualified operator only, following the correct procedures. The blower with motor and control must not be used in a potentially explosive atmosphere. The hopper may only be used in such atmosphere if the bottom flap has been fitted with an explosionproof power switch. The power switch will be marked with an explosion-proof label. IMPORTANT! The person in charge of the placing/operation and or owner is responsible for the prescribed and adequate installations, corresponding to the local regulations. In other words, only authorized or trained personnel is allowed to install the equipment. Should the equipment be interfered with by unauthorized or untrained personnel leading to damage, or should the consumer allow the equipment to be interfered with in this manner by third parties, then all claims under guarantee relating to the entirety of the object concerned become null and void. The right to carry out changes in design is reserved, without however incurring the obligation to effect such changes, even in equipment already supplied. This information is based on our present state of knowledge and is intended to provide general notes on our products and their uses. It should not therefore be construed as guaranteeing specific properties of the products described or their suitability for particular applications.

5 Rev. 03 Con-Evator Page Design Con-Evator SVR comprises Description Pos. Material Control (1) Steel / Material hose (2) Plastic Motor (6) - Blower (7) Cast aluminium Vacuum hose (8) Plastic Bottom flap (13) Stainless Suction hose (14) Electroplated Blow-back valve (80) Cast aluminium Silencer (81) Steel Lid (82) Stainless Hopper (83) Stainless Proximity switch - Base (85) Stainless Base filter (86) Stainless synthetic The Con-Evator is available in the following versions: A) Con-Evator with stainless steel hopper and separate control Control separated from the machine with an extra long cable. Applicable to locations difficult to access at which adjustment of the control may be impeded or for applications requiring a stainless steel hopper. R2378_R01

6 Rev. 03 Con-Evator Page Operating principles Conveying (drawing R2369) 1. By means of the blower (7), a vacuum is generated inside the hopper loader (83); the blower is driven by an electric motor (6). This causes the bottom flap (13) to close against the outlet of the hopper resulting in a vacuum in both the conveying hose (2) and the suction probe (14). Ambient air is consequently sucked in through the outer pipe of the suction probe, carrying material with it to the hopper through the suction pipe (14). 2. BLOWER ON time (the time the blower is required to generate a vacuum) is set at the control. 3. During conveying the conveying hose (2) may be cleared. A line clearing valve located right above the suction probe opens in a preset time integrated in the conveying time. Air is admitted into the system, now via the suction hose instead of the suction probe, and thereby clearing of the hose is effected. See section 5.0 Accessories. R When the blower is turned off the weight of the material sucked into the hopper loader will cause the bottom flap (13) to be pressed down and the material to fall into the intermediate hopper (5). 5. If there is sufficient room in the intermediate hopper for all the material, the bottom flap will automatically be released against the outlet (15) and indicate to the control, via the bottom flap, that a new loading cycle should be started. 6. If there is insufficient room in the intermediate hopper for all the material, the material will hold the bottom flap down, and a new loading cycle will only be started when the material level has dropped sufficiently to allow the bottom flap to close against the outlet Filter cleaning 1. A filter (21), located between the blower (7) and the hopper loader (10), protects the blower (7) against dust. 2. Immediately before each loading cycle, the filter is automatically cleaned by the blower reversing its rotating direction. This process also cleans the bottom flap (13).

7 Rev. 03 Con-Evator Page 6 2a. If a blow-back valve (80) has been fitted, the blower will not reverse its rotating direction, only the position of the valve will switch so to utilize the outlet air of the blower for filter cleaning. 3. The air that is forced down through the hopper loader will be sent out through the base filter (11). The filter will catch any dust/particles that would otherwise be blown into the ambient air.

8 Rev. 03 Con-Evator Page Certificates IQ-Net Certificate

9 Rev. 03 Con-Evator Page ISO Certificate

10 Rev. 03 Con-Evator Page TECHNICAL DATA 3.1 Technical specifications Con-Evator LT-I 3 LT-I 4 LT-I 5 LT-I 6 Supply voltage 3~50/60 Hz V Control voltage 24Vac 24Vac 24Vac 24Vac Motor power [Kw] 0,4/0,5 1,1/1,3 1,3/1,6 3,4/4 Installed power [Kw] 0,5/0,6 1,2/1,4 1,4/1,7 3,5/4,2 Motor [rpm] 2820/ / / /3470 Air flow / / mm water column 200/ mm water column 150/170 Water column, mm 1500/ / / /3200 Noise level Conveying hose, inside dia. [Ø mm] ,5 50,8 Vacuum hopper SVR 4 SVR 8 SVR 16 SVR 26 SVR 50 SVR 75 SVR 100 SVR 150 SVR Capacity [litres] Conveying hose inside, dia. [Ømm] ,5 50,8 50,8 50,8 50,8 50,8 Vacuum, receiver kg Conveying hose length[m] Interconnecting cable[m] Telescopic suction, probe [m] 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 0,8 Outer pipe length[mm] Outer pipe, outside dia. [Ømm] ,5 76,2 76,2 76,2 76,2 76,2 Inner pipe length[mm] Inner pipe, dia[mm] ,5 50,8 50,8 50,8 50,8 50,8 We reserve the right to make changes to the specifications without notice. 3.2 Typeplate The identification number consists of a code (A) and (B),a type number (C)and a serial number (D) Codes (A) and (B): The first and last digit (A) of the code identify the year in which the machine was manufactured. Example: 0SA7=2007 The two letters in the middle (B) of the code identify the machine. SA = standard machine KA = special customised design HT = HT/LT model EX = special marking for separate controls ES = special marking for substitute controls

11 Rev. 03 Con-Evator Page Type (C) The type number consists of two digits characterising the machine type: SVR4: 80 SVR75: 41 SVR8: 82 SVR100: 42 SVR16: 87 SVR150: 43 SVR26: 88 SVR200: 44 SVR50: Serial number (D) The serial number is a five-digit number referring to the individual manufacturing number of the machine. 3.3 Dimensioned drawings All measurements are in mm. R2384 R2371

12 Rev. 03 Con-Evator Page Capacity table Con-Evator Horizontal SVR 4 Blower 0.4 kw Capacity table [kg/h] kg/h Vertical Conveying Distance [m] Con-Evator Horizontal SVR 8 Blower 0.4 kw Capacity table [kg/h] kg/h Vertical Conveying Distance [m] Con-Evator Horizontal SVR 4 Blower 1,1 kw Capacity table [kg/h] kg/h Vertical Conveying Distance [m] Con-Evator Horizontal SVR 8 Blower 1,1 kw Capacity table [kg/h] kg/h Vertical Conveying Distance [m]

13 Rev. 03 Con-Evator Page 12 Con-Evator Horizontal SVR 16 Blower 1,1 kw Capacity table [kg/h] kg/h Vertical Conveying Distance [m] Con-Evator Horizontal SVR 26 Blower 1,3 kw Capacity table [kg/h] kg/h Vertical Conveying Distance [m] Con-Evator Horizontal SVR 50 Blower 3,4 kw Capacity table [kg/h] kg/h Vertical Conveying Distance [m] Con-Evator Horizontal SVR 50 Blower 3,4 kw with blow-back Capacity table [kg/h] kg/h Vertical Conveying Distance [m] The above capacities kg/h at the respective distances set out in the table are based on the assumption that the vacuum hopper is completely filled during each conveying cycle. Over and above to the vertical and horizontal conveying distances, the available capacity depends on the characteristics of the pellet, size and bulk density. The specified capacities are based on a general bulk density of 0.6 kg/land the above capacity table states recommended values only.

14 Rev. 03 Con-Evator Page Noise level Noise level dba according to DS/ISO 3746 (without conveying): LT-I 3 /SVR 4-8 LT-I 4 /SVR 16 LT-I 5 /SVR 26 LT-I 6 /SVR

15 Rev. 03 Con-Evator Page ASSEMBLY /DISASSEMBLY 4.1 Assembly Assembly of standard SVR hopper loader with LT-I blower 1. Fit the LT-I blower (88) on a wall, a machine or on another stable object using the angle bracket (5).For dimensions, see section 3.3 fig. 2. Remove the tape that secures the bottom flap during transportation. 3. Fit the SVR hopper directly on the lid of a machine hopper, a bin or a silo mouth-diameter Ø 200.Mount the hopper in the four assembly holes as shown in fig.r2029 section 4.0 Assembly. 4. Fit the conveying hose (2) on the inlet pipe (89) of the SVR hopper using the clip (90). 5. Fit the conveying hose (2) on the suction probe (14) using the clip (90). 6. Fit the vacuum hose (8) between the inlet branch (25) of the angle bracket and the lid (9) of the hopper. 7. Fit the interconnecting cable between hopper (83) and control (1) using the plug connection (87). 8. Connect the machine to the mains voltage. First check that the voltage available corresponds to the voltage specified on the type plate of the unit. 9. If the LT-I blower has been supplied with a blow-back valve, the valve is to be connected to pressure air supply 5-7 bar. SVR 4-50 SVR R2029 R2040

16 Rev. 03 Con-Evator Page Assembly of Con-Evator with separate control 1. Fit hopper, suction probe and suction hose as described in section Fit the control at an appropriate location. 3. Wire following the diagram. 4.2 Disassembly 1. Turn off the machine on the main switch. 2. Remove plug/wire from the mains voltage. 3. Remove the bolts in the flange of the Con-Evator. 4. Disassemble the Con-Evator. 4.3 Electric connection 1. First, assemble the Con-Evator. See section Check that the voltage available corresponds to the voltage specified on the type plate of the unit. See section Fit the unit on an intermediate hopper or another hopper. Connect to mains voltage. 4. Check that the phases of the Con-Evator have been connected in the proper sequence. Check this during conveying and filter cleaning by comparing the direction of rotation the rotating indicator located on the fan hood. If the Con-Evator has been installed properly, air is discharged through the hose connection, when the blower starts shortly for filter clearing 4.4 Control The Con-Evator Control is designed for continuous operation of a vacuum blower 0.1kW - 3,4 kw, V AC for conveying of plastic material. The external inputs for the control are: Position of bottom flap in hopper loader External level control External capacitive sensor. The Con-Evator has 4 (four) basic standard conveying programs. P1: Conveying with filter cleaning (reverse) before conveying (old type M312) Conveying of powder with filter cleaning with compressed air from compressed air container. P2: Conveying with filter cleaning (reverse) after conveying (old type M313) P3: Conveying with filter cleaning via return air valve (old type M314) P4: Conveying in closed system with slide valve (old type M316)

17 Rev. 03 Con-Evator Page Programme Choice The Con-Evator is delivered from factory with Program P1 as standard The program is selected on the DIP-switches on the back of the control front plate, as follows: 1. Disconnect the conventional power to the Con-Evator. 2. Dismantle the front plate/cover from the control 3. Select on the DIP switches one of the following possibilities: P1 = P2 = P3 = P4 = 4. Mount the front plate/cover and connect the conventional power. 5. Turn on the Con-Evator. The display will for 2 seconds show which program is chosen. The Con-Evator will then be operating in this program Programming The Con-Evator control is equipped with 4 operating bottoms and 2 bottoms with 2 functions. = Access to Programme mode / one parameter step down = Selected value one step up = Selected value one step down = Accept of value. Alarm lamp will flash 3 times = accept of new value = Alarm reset 1. Priority = Start / Stop 2. Priority = Out of Programme mode 1. Priority = Quick selection. 2. Priority

18 Rev. 03 Con-Evator Page List of parameters Program P1 Interval Factory settings Recommended sec. Recommended-sec Powder conveying 1: Filter cleaning/reverse : Pause See : Conveying Depend of process Depend of process 4: Ratio Selector Depend of process Depend of process 5: Ratio-Selector 2 5,360 0 Depend of process Depend of process 6: Pipe cleaning : Pause 2 drain of material from loader See Program P2 Interval Factory Recommended sec. settings 1: Conveying Depend of process 2: Ratio selector Depend of process 3: Ratio selector Depend of process 4: Pipe cleaning : Pause See : Filter cleaning/reverse : Pause 2 drain of material See Program P3 Interval Factory Recommended sec. settings 1: Filter cleaning/ Blow back valve : Conveying Depend of process 3: Ratio selector Depend of process 4: Ratio selector Depend of process 5: Pipe cleaning : Pause 1 drain of material : Pause 2 filter cleaning Program P4 Interval Factory Recommended sec. settings 1: conveying valve open Depend of process 2: conveying pipe cleaning valve closed Depend of process 3: Pause 1 drain of material Recommended settings Motor size LT-I 3/0.4kW LT-I 4/1.1kW LT-I 5/1.6kW LT-I 6/3.4kW Pause after filter cleaning Pause after conveying

19 Rev. 03 Con-Evator Page Operation During operation the display will show the actual value of the selected parameter. The function will at the time be shown with diode at the front panel During Pause the display will show S Indicates that the Con-Evator is turned off by pressing the Stand-By bottom OFF Indicates that the Con-Evator is stopped due to an external command H Indicates that the bottom flap is not closed and the Con-Evator is waiting on a new transport cycles. L Indicates that the bottom flap is closed hopper loader is empty. E Indicates that motor for blower has been turned off by thermal protection.

20 Rev. 03 Con-Evator Page Special functions The Con-Evator control is equipped with the following features: Quick-function The Con-Evator control has a Quick function for setting the conveying time. Before start of conveying press and hold the button The display will start blinking and the setting of the transport time will increase. When the hopper loader is full (no flow of material) release the button. The setting indicated on the display is the new conveying time (Accept indicated by alarm lamp) Conveying alarm If the Con-Evator has been running 3 (Three) conveying cycles without additional material it will go into conveying alarm The number of conveying cycles before the conveying alarm is activated can be selected between 0 and 5 Press and Press 2 x : Number of conveying cycles will be show non the display. Note: By 0 the conveying alarm will not be activated.. The operating of the Con-Evator will continue during conveying alarm. The conveying will automatically be reset if the high level sensor has been activated. The conveying alarm can be reset by pushing the reset button. Factory settings The factory settings can be re-activated with the following procedure. 1: Turn off the Con Evator by the main switch 2: Press and hold + at the same time. 3: Turn on the machine and the factory settings has been reactivated for all 4 programs Note: Individual settings of the parameters can be necessary to obtain correct operation.

21 Rev. 03 Con-Evator Page 20 Wireless Remote Control For further user comfort Labotek has developed a wireless remote control which is able to identify and service up to 99 units. It is strongly recommended to user different numbers for different Con-Evators. 1. Turn off the Con-Evator at the main switch 2. Press and hold 3. Turn on the machine at the main switch. A machine number is shown gradually increasing from 01 to At the actual machine number release the button. The Com/alarm lamp blinks 3 times to indicate accepts of number. Note: Machine number 00 can not be used. The following buttons at the control panel corresponds with the following buttons at the remote control. = = = = = = Communication via the remote control is done the following way: 1: Point the remote control at the Con-Evator control and press 2: The display in the control will show the ID number. 3: Press the ID number at the remote control The ID number will disappear from the display and the remote control is now in communication with the control of the Con-Evator and changes of parameters can be done. The communication between the remote control and the Con-Evator control will automatically be disconnected 30 sec after latest change of parameters. Program-Version 1: Turnoff the Con-Evator at the main switch 2. Press and hold 3. Turn on the Con-Evator at the main switch and the program version will be show non the display for 2 seconds.

22 Rev. 03 Con-Evator Page 21 External Connections The Con-Evator can be controlled, on/off, by a non potential signal The following sensors can be connected to the control Button flap PGT Magnet switch SVR Rotating level control drying hopper DH / Material hopper Capacitive sensor Material hopper / Silo Ratio-Selector Pipe cleaning valve Slide valve Blow Back valve Alarm lamp Compressed air valve (filter cleaning) Alarms The Con-Evator is equipped with the following alarms 1:» E» shown in the display indicates that motor is overheated and is disconnected by the thermonal protection. The Con-Evator is totally disconnected and the alarm lamp is blinking. The temperature is measured by a clixon contact built in the motor. Terms for resetting: Motor cooled to temperature with in the specifications. Turn off and turn on the Con-Evator at the main switch. 2: Transport alarm By insufficient martial flow the transport alarm is activated (Com-lamp and external alarm lamp (se 4.5.4) Terms for resetting: Sufficient material flow or press bottom 5. R2382

23 Rev. 03 Con-Evator Page Adjustment of the suction probe In order to achieve maximum and consistent conveying it is important that the suction probe has been adjusted correctly. 1. Press the suction probe down into the granules. 2. Loosen the finger screw (46) to release the suction probe (14) from the outer tube (16). 3. While the Con-Evator is conveying, adjust the suction probe and the outer tube to each other until consistent and uniformed conveying has been established. 4. Tighten the finger screw (46) to secure the suction probe and the outer tube in the adjusted position Fig R Adjusting the bottom flap During normal operation the bottom flap should not be adjusted unless it fails. See section 6.3 and 6.6 Maintaining the bottom flap. 4.6 Start Turn the main switch to position 1. The machine will start after approx. 20 seconds. Before starting: see section 4.1 about machine settings, if required. 4.7 Operation 1. Once the Con-Evator has been started, operation is fully automatic (usually in batch processes as the intermediate hopper will occasionally be full) as the bottom flap acts as level control starting and stopping the loading cycle. 2. To ensure maximum performance and life of the machine, proper maintenance should be strictly observed. See section 6.0 Maintenance. 4.8 Stop 1. Stop the Con-Evator by turning the main switch at the control to position 0, or push the reset/stand-by button.

24 Rev. 03 Con-Evator Page ACCESSORIES 5.1 List of accessories Pos. Description LT. no. 44 Lamp, warning, missing material, 24Vac LT no Lamp, warning, acoustic alarm LT no Bottom flap, SVR, teflon coated 45 Pipe clearing valve, complete Ø32 pipe LT no Pipe clearing valve, complete Ø38 pipe LT no Pipe clearing valve, complete Ø44.5 pipe LT no Pipe clearing valve, complete Ø50.8 pipe LT no Bracket and air filter, for suction probe, Ø32 LT no Filter LT no Bracket and air filter, for suction probe, Ø38 LT no Filter LT no Bracket and air filter, for suction probe, Ø44.5 LT no Filter LT no Bracket and air filter, for suction probe, Ø50.8 LT no Filter LT no Base filter, SVR 4-50 LT no Filter bag, return air SVR 4-50 ltr. LT no Compressed air filter clearing, 2ltr for SVR 4-8 placed at lid LT no Compressed air filter clearing, 2ltr for SVR placed at lid LT no R Connecting and installing accessories Installing filter for suction probe A filter is fitted on the suction probe to prevent that dust and granular pellets inside the intermediate hopper are dispersed on the floor when the Con-Evator is reversing the air flow to clean the disc filter most common at short conveying distances.

25 Rev. 03 Con-Evator Page Remove the conveying hose from the suction probe. 2. Press the filter holder (56) over the inner and outer tube (14) (16) of the suction hose. Check that the O-ring (57) has been fitted correctly. 3. Fit the cartridge filter (58), the disc (59) and the star handle (60) on filter holder (56). 4. Fit the conveying hose on the inner tube (14) R Installing the line clearing valve It is recommended to install a line clearing valve at vertical lifts exceeding 3 metres for LT-I 3 and LT-I 5, and 5 metres for LT-I 6. The line clearing valve prevents material which is in the vertical conveying hose during conveying from falling back and becoming stuck in the hose when conveying stops. By the end of each conveying cycle the line clearing valve admits air into the conveying hose at the point just above the suction probe. The line clearing valve facilitates start of a new conveying cycle, as no mass of compact material is stuck in the pipes. 1. Fit the T-pipe (61) near by the suction probe (14). 2. Fit the conveying hose (2) on the T-pipe (61). 3. Fit the line clearing valve (45) on the T-pipe (61). 4. Connect compressed air supply 4-10 bar to the connecting branch (62) of the line clearing valve. 5. Wire (63) between line clearing valve and control, follow the diagram. OBS! For reason of weight the line clearing valve should be fitted at an appropriate location e.g. a wall. R1197

26 Rev. 03 Con-Evator Page Installing the Teflon-coated bottom flap A Teflon-coated bottom flap is used where the conveyed material has a tendency to stick to the bottom flap, due for instance to static electricity. Granular pellets stuck to the bottom flap may impede the full closure of the bottom flap, thus causing the hopper to leak at the bottom and preventing the generation of vacuum. 1. Turn off the machine by turning the power switch to position Disconnect the mains voltage. 3. Dismount the Con-Evator from the processing machine. 4. Turn the machine upside down or sideways and dismount the bottom flap by removing the screw and the disc (66). 5. Clean of dust and soil from the assembly roller (67). 6. Fit the Teflon-coated bottom flap (51) on the assembly roll (67), the Teflon-coated side facing the outlet branch. To adjust the bottom flap dislocate the flap in the longish hole until the outlet branch is fully covered. R Adjust the spring function of the bottom flap, if required. See section Install the Con-Evator on the processing machine and connect to mains voltage.

27 Rev. 03 Con-Evator Page Fitting the alarm lamp 1. Turn the main switch to position 0 and unplug blower. 2. Remove the front cover of the control (35). 3. Remove blind plugs (68) from the top face of the control. 4A. Fit alarm lamp (44) on the bracket in the free assembly holes. 4B. Fit alarm lamp (44) on the top face of the control in the free assembly holes. 4C. Fit alarm lamp (44) on the bracket in the free assembly holes. 5. Wire in the control follow the diagram. 6. Fit the front cover (35). R2379

28 Rev. 03 Con-Evator Page MAINTENANCE - SVR The filter should be checked and cleaned at least once a week. A worn filter must been replaced. 6.1 Maintaining the air filter and the base filter Note! The air filter and the base filter should be checked at every 24 hours of operation as a minimum Air filter 1. Turn off the machine on the power switch. Open the lid on the SVR hopper loader. 2. Remove the filter (93) and the filter bag by loosening the fly nut (92). 3. Pull the filter bag over the air filter. 4. Shake to have the dust bag cleared. Clean using compressed air, if necessary 5. Clean the air filter using compressed air, and check that the filter is in working order. 6. Clean the filter surfaces. 7. Replace the filter bag over the filter and fasten the filter. 8. Close the lid Base filter 1. Turn off the machine on the power switch. Open the snap lock (94). 2. Remove the fine base filter (95) from the base filter (96). Clean using compressed air and check that the filter is in working order. 3. Insert the filter mesh and close the snap lock (94). R2043 R2042

29 Rev. 03 Con-Evator Page Maintaining the bottom flap SVR (stainless steel) The function of the bottom flap should be checked once a month. A damaged or bent bottom flap must be replaced. 1. Remove the base filter. 2. Check visually whether the bottom flap is intact. 3. Verify that the bottom flap can move freely. 4. Check that the gap between the discharge branch and the bottom flap is approx mm when the bottom flap hangs loose. 5. Replace the filter (96). 6.3 Adjustment of the magnetic switch 1. Clear the intermediate hopper 2. Turn off the machine by turning the power switch to position Remove the filter (96). 4. Remove plug and fit test lamp (97) (optional). 5. The test lamp (97) is to lit up when the bottom flap hangs lose or has been closed. When the bottom flap is fully open, the test lamp must turn off. 6. Adjust the activation point by adjusting the two screws that hold the fixture for the magnetic switch (100). The fixture is adjusted up-and-down so that the magnetic switch (99) is moved to-and-fro the magnet (98). 7. When the activation point has been adjusted, tighten the screws and replace the filter (96) 10-30mm R2045 R2044

30 Rev. 03 Con-Evator Page TROUBLESHOOTING 7.1 The Con-Evator does not start Has the Con-Evator been connected Connect properly No properly to the mains voltage? Yes Is the power switch turned to position 1? No Turn the power switch to position 1. Yes Are the control fuses in working order? No Replace fuse. Yes Has the overload protection disconnected the control voltage? No Has the bottom flap been properly adjusted? See section and No No 7.2 The Con-Evator capacity has been reduced Press the reset button at the overload protection. Adjust the bottom flap. See section and Is the disc filter clean and unclogged? No Clean or replace the filter. Yes Has the suction probe been adjusted correctly? No Yes Has the conveying time been adjusted correctly (setting of conveying time with reference to conveying distance) Yes Is the phase sequence correct? Replace phase, if necessary. Yes Does the blow-back valve change position? No Adjust the suction probe correctly. See section Adjust the conveying time. See section No Check according to section 4.3. No 7.3 The Con-Evator stops at short intervals Because the overload protection has been activated. Check: Compressed air connection, air filter on solenoid valve, connection of solenoid valve. Is the disc filter cleaned and unclogged? Yes Have the settings on the overload protection been adjusted correctly? Yes Does the machine start at short intervals? No No No Clean or replace the disc filter. See section 6.1 Check settings. Adjust according to diagram, if necessary. Increase conveying time. See section

31 Rev. 03 Con-Evator Page REPAIRS 8.1 Replacement of fuse for control voltage 1. Turn the main switch (28) to position 0 and unplug blower. 2. Remove the front cover (35) of the control to allow access to the fuses: (31A) Primary voltage (31B) Secondary voltage 3. Grab the small flap on the fuse and pull it outwards 4. Insert new fuse (31) by pushing it firmly in place. 6. Replace the front cover (35) on the control and connect the machine. R Replacement of bottom flap SVR (stainless steel) 1. Clear the vacuum hopper loader. 2. Disconnect the machine by turning the power switch to position Disconnect the mains voltage. 4. Dismount the vacuum hopper loader from the processing machine. 5. Turn the hopper upside down or sideways. Remove the bottom flap by removing the split pin (101). 6. Remove the magnet (98) and the balance weight (102) at the bottom flap. 7. Fit the magnet (98) and the balance weight (102) on a new bottom flap. 8. Clear dust and soil from the fixture. 9. Fit the bottom flap in the fixture using the split pin (101). 10. Adjust the magnetic switch as described in section Replace the vacuum hopper loader on the processing machine and connect mains voltage. R2046

CVR-625. Compact Vibrating Rod Instruction Manual

CVR-625. Compact Vibrating Rod Instruction Manual CVR-625 Compact Vibrating Rod Instruction Manual BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS

More information

Hopper Loaders S Series

Hopper Loaders S Series Hopper Loaders S Series English The design criteria and the construction modalities of these Single-phase Loaders put the S Series at the top of quality and performance. The workmanship, the body entirely

More information

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference.

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference. AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference. MODEL MC 3000 SPECIFICATION Input Volts: 208-230/430 VAC, 60Hz, 3 Phase

More information

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00 Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION

More information

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100 V acuum Pumps Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100 www.republicsales.com Revised 02.15 2015 Republic Sales & Manufacturing Single Stage Rotary Vane

More information

Electric Diesel Pump EDP/12, EDP/24

Electric Diesel Pump EDP/12, EDP/24 INSTRUCTION MANUAL Electric Diesel Pump EDP/1, EDP/4 S1940, Rev C Congratulations on purchase of this World Class Electric Diesel Pump! Portable Diesel transfer pumps designed for everyday use in Agricultural,

More information

DIAMOND POINT VIBRATING PROBES

DIAMOND POINT VIBRATING PROBES DIAMOND POINT VIBRATING PROBES DP130 DP120 DP140 DP150 Instruction Manual Third revision, April 2016 Hycontrol Ltd., Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, U.K. Tel: + 44 (0)1527

More information

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS Installation and Operating Instructions VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90 1. Model numbering and nameplate format 1.1 Model numbering Example: SBI / SBN

More information

INSTRUCTION MANUAL SVEA-ALLROUND GRAIN AUGER 152 mm

INSTRUCTION MANUAL SVEA-ALLROUND GRAIN AUGER 152 mm INSTRUCTION MANUAL SVEA-ALLROUND GRAIN AUGER 152 mm Original User Guide Subject to alteration Sveaagri AB Vingåkersvägen 73, SE-641 39 Katrineholm TEL +46(0)150 48 77 00, FAX +46(0)150 48 77 77 www.sveaagri.com

More information

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320 Inlet Controller SB 2000 USER'S MANUAL AUTO OPEN MANUAL PUSH TO SEARCH NEXT STAG E CLOSE Aerotech, Inc. FORM: QM 1320 4215 Legion Dr. Mason, MI 48854-1036 USA Rev. 3, Sept. 1997 Ph. (517) 676-7070 Fax

More information

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25 V acuum Pumps Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25 www.republicsales.com Revised 10.14 2014 Republic Sales & Manufacturing Single Stage Rotary Vane Vacuum

More information

MANN+HUMMEL ENTARON XD. Installation and Maintenance Manual. Version 0709

MANN+HUMMEL ENTARON XD. Installation and Maintenance Manual. Version 0709 MANN+HUMMEL ENTARON XD Installation and Maintenance Manual Version 0709 Contact information This installation and maintenance manual is a component part of the scope of delivery. It must be kept in a safe

More information

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS Model 31801 and 31800 Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS INDUSTRIAL DIAPHRAGM PUMPS FEATURES Run Dry Ability Self-Priming Thermal Overload Protected Motor Easy Installation Low Amp Draw Compact

More information

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009 HOT WASHER MODEL NO: KING 125 PART NO: 7320170 OPERATION & MAINTENANCE INSTRUCTIONS LS1009 INTRODUCTION Thank you for purchasing this Hot Washer. This machine is a portable, high pressure power washer,

More information

D10 Page. Contents. Complete Equipment with Scope of Supplies 2. Accessories 3

D10 Page. Contents. Complete Equipment with Scope of Supplies 2. Accessories 3 01.2009 UK D10 1 D10 Page Contents Complete Equipment with Scope of Supplies 2 Accessories 3 Spare Parts D10-III 230V / 400V 4-5 Motors D10 universal 6 Transport shaft, mixing shaft 7 Electric Control

More information

Troubleshooting. This section outlines procedures for troubleshooting problems with the operation of the system:

Troubleshooting. This section outlines procedures for troubleshooting problems with the operation of the system: Troubleshooting This section outlines procedures for troubleshooting problems with the operation of the system: 4.1 System Error Messages... 4-2 4.2 Prep Station Troubleshooting... 4-6 4.2.1 Adapter Not

More information

Pressure chlorine changeover unit C 7520

Pressure chlorine changeover unit C 7520 BW 2 24 04 / 1 Content 1. Scope of delivery 2. Device description 3. Installation 4. Operation 5. Shutdown 6. Maintenance 7. Troubleshooting 1 Scope of delivery The chlorine gas changeover unit C 7520

More information

CRS-D Powder Coating Booth with Reverse Jet Cleaning System

CRS-D Powder Coating Booth with Reverse Jet Cleaning System Operating Instructions CRS-D Powder Coating Booth with Reverse Jet Cleaning System CRS-D (J) 27 1 1 1 2 2 2 4 4 4 3 3 3 CRS-D Booth with Reverse Jet Cleaning System 1 10 2 3 9 12 11 11 1 Exhaust air unit

More information

INSTRUCTION MANUAL. Direct Drive Air Compressor 2320, REV A. 1.

INSTRUCTION MANUAL. Direct Drive Air Compressor 2320, REV A. 1. INSTRUCTION MANUAL 2320, REV A Direct Drive Air Compressor CONSTRUCTION DUAL MATERIAL CONSTRUCTION i) The cylinder block is made up of cast iron that prevents wear & tear thus imparting longevity to the

More information

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS Installation and Operating Instructions VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS Models 1, 3, 5, 10, 15, 20, 32, 45, 64, 90, 120, 150 1. Model numbering and nameplate format 1.1 Model numbering Example:

More information

SBCNNS. Abrasive Blast Cabinet Assembly & Operating Instructions

SBCNNS. Abrasive Blast Cabinet Assembly & Operating Instructions SBCNNS Abrasive Blast Cabinet Assembly & Operating Instructions READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT. This manual provides important information on proper operation & maintenance.

More information

Electric Fuel Pump FPM

Electric Fuel Pump FPM INSTRUCTION MANUAL Electric Fuel Pump FPM S1590, Rev B LISTED MOTOR FPM-12, FPM-24, FPM-115, FPM-220 Congratulations on purchase of this World Class Electric Fuel Pump! Elbow This is an Electric Fuel Pump.

More information

Likorall. LOAD TESTING 12 Mechanical lowering load test (242) Maximum load rail system... DOCUMENTATION 14 Instructions / Instruction guide...

Likorall. LOAD TESTING 12 Mechanical lowering load test (242) Maximum load rail system... DOCUMENTATION 14 Instructions / Instruction guide... 6.1 Likorall 200, 240, 242, 243, 250 Periodic inspection 24-06-26 Lift type:... Prod No:... Version: Serial No:... Prod. Year:... Customer Reference: Contract No:... Name:... Address:... (Zip Code)...

More information

OPERATOR S MANUAL STUDPRO SERIES

OPERATOR S MANUAL STUDPRO SERIES OPERATOR S MANUAL STUDPRO SERIES Capacitor Discharge Stud Welder MODELS: StudPro 2500XI StudPro 2500XIP StudPro 3125XI StudPro 3750XI CONTENTS Description Pages Safety 2 Specifications and Features 3 Product

More information

VAL6 KBE5S. Service Manual

VAL6 KBE5S. Service Manual VAL6 KBE5S Service Manual 1 2 Specifications Type VAL6 KBE5S Heat Output 111,000BTU/h Fuel Kerosene, Diesel Tank Capacity 9 gallons Fuel Consumption 0.85gallon/h Power Source 120V, 60Hz single phase Power

More information

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B) Spring-Set Disc Brakes P/N 8-078-98-0 effective 6/6/0 Installation and Service Instructions for 87,000 & 87,00 Series Self-Adjust Brakes (rev. B) Tools required for installation and servicing: 3/8 hex

More information

Troubleshooting 3Z8 038 Rev B

Troubleshooting 3Z8 038 Rev B Troubleshooting 3Z8 038 Rev B INSTRUCTIONS WARNING INJECTION HAZARD This form is only a quick reference for troubleshooting Graco sprayers. To reduce the risk of serious injury, including fluid injection,

More information

Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide

Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide Arch HTH Water Chemicals Commercial Equipment Trouble Shooting Guide 8/28/00 TROUBLESHOOTER S GUIDE PROBLEM CAUSE SOLUTION Insufficient water flow to chlorinator Check water flow through Flow Controller

More information

SCISSOR LIFT Model MR6K-38 /161108A 6,000lb Capacity Operation Manual

SCISSOR LIFT Model MR6K-38 /161108A 6,000lb Capacity Operation Manual SCISSOR LIFT Model MR6K-38 /161108A 6,000lb Capacity Operation Manual (Version A) 2009. Apr. CONTENT 1. Safety Note, Caution and Warning Important Information Safety Instructions 2. Technical Manual Product

More information

Installation Operation Maintenance ADDENDUM

Installation Operation Maintenance ADDENDUM Installation Operation Maintenance ADDENDUM Bulletin #: PS-IOM-HYPO2-0111-A FACTORY SERVICE POLICY If you are experiencing a problem with your Pulsafeeder pump, first review the IOM, and consult the troubleshooting

More information

Installation- and maintenance instruction BENTOFLEX ST 108 PL

Installation- and maintenance instruction BENTOFLEX ST 108 PL Installation- and maintenance instruction BENTOFLEX ST 108 PL 1 171 625 30 03-01 178 001 13 DESCRIPTION COMPONENTS 1. Reset button 2. Control box 3. Ignition transformer 4. Ignition cables 5. Nozzle assembly

More information

Heavy Duty Sprayer Owners Manual Model MS-O

Heavy Duty Sprayer Owners Manual Model MS-O Heavy Duty Sprayer Owners Manual Model MS-O Table of Contents Warranty 4 Warning 5 Assembly and Preparation 6 Operation 7 Cleaning and Storage 7 Standard Spray Gun & Parts List 8 Trigger Style Spray Gun

More information

SELF PRIMING CHEMICAL SERVICE PUMPS

SELF PRIMING CHEMICAL SERVICE PUMPS SELF PRIMING CHEMICAL SERVICE PUMPS INSTALLATION AND OPERATING INSTRUCTIONS This Manual covers: SELF PRIMING MODEL RANGE J50ECX TO J250ECX STAINLESS STEEL*, and NON METALLIC SEAL PUMP MODEL: SERIAL NO:

More information

Retrofitting Kit Filter Cleaning for Cable Coater ECC 700

Retrofitting Kit Filter Cleaning for Cable Coater ECC 700 Instruction Sheet P/N 397 880 B English Retrofitting Kit Filter Cleaning for Cable Coater ECC 700 Safety Instructions WARNING: Allow only qualified personnel to perform the following tasks. Observe and

More information

CFT24 &CFT230 PART NOS:

CFT24 &CFT230 PART NOS: FUEL TRANSFER PUMP Model Nos. CFT12, CFT24 &CFT230 PART NOS: 7160010, 7160020 & 7160030 INSTALLATION & OPERATING INSTRUCTIONS ORIGINAL INSTRUCTIONS GC05/18 REV 5 INTRODUCTION Thank you for purchasing this

More information

FD 404A1 High-Capacity Air Jogger

FD 404A1 High-Capacity Air Jogger FD 404A High-Capacity Air Jogger 7/203 OPERATOR / PARTS MANUAL FIRST EDITION TABLE OF CONTENTS SUBJECT PAGE DESCRIPTION SPECIFICATIONS UNPACKING SAFETY FEATURES & CONTROL PANEL 2 OPERATION 3 BASIC JOGGING

More information

BULL 240 EBS INDUSTRIAL VACUUM. Operator s Manual VAC.BULL240.EBS. SASE Company, LLC 2475 Stock Creek Blvd. Rockford, TN 37853

BULL 240 EBS INDUSTRIAL VACUUM. Operator s Manual VAC.BULL240.EBS. SASE Company, LLC 2475 Stock Creek Blvd. Rockford, TN 37853 BULL 240 EBS INDUSTRIAL VACUUM Operator s Manual VAC.BULL240.EBS SASE Company, LLC 2475 Stock Creek Blvd. Rockford, TN 37853 P 800.522.2606 F 865.745.4110 SASECompany.com SAFETY INSTRUCTIONS Operators

More information

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B)

Installation and Service Instructions for 87,000 & 87,100 Series Self-Adjust Brakes (rev. B) Spring-Set Disc Brakes P/N 8-078-98-0 effective 03/6/4 Installation and Service Instructions for 87,000 & 87,00 Series Self-Adjust Brakes (rev. B) Tools required for installation and servicing: 3/8 hex

More information

MC2500. Installation and Operation Manual

MC2500. Installation and Operation Manual MC2500 Installation and Operation Manual Important: This manual contains specific cautionary statements relative to worker safety. Read this manual thoroughly and follow as directed. It is impossible to

More information

OPERATION INSTRUCTIONS GFA-W-150\300\500\1000

OPERATION INSTRUCTIONS GFA-W-150\300\500\1000 OPERATION INSTRUCTIONS HORIZONTAL SELF-SUCTION FILLER SERIES GFA-W-10\300\00\1000 Please operate in accordance with the instructions strictly. CONTENTS Overview Maintenance and Service Application Replacement

More information

Ph: (07) Fax: (07) Pump Manual

Ph: (07) Fax: (07) Pump Manual sales@scintex.com.au www.scintex.com.au Ph: (07) 3137 0135 Fax: (07) 3041 0541 Pump Manual 12V 75LPM Vane Pump & Vane Pump Station SPEP12V75 & SP12VFS75 SPEP12V75 SP12VFS75 Parts List No. Part Name QTY

More information

DCE 100 Series Dust Filter

DCE 100 Series Dust Filter Installation, Operation and Maintenance Manual DCE 100 Series Dust Filter Publication 2638B (GB) 0702 1419-8000A Donaldson Torit DCE reserve the right to alter design without notice. Freedom from patent

More information

Inlet Controller SB3500 USER'S MANUAL

Inlet Controller SB3500 USER'S MANUAL Inlet Controller USER'S MANUAL NOTICE Every effort has been made to ensure that this manual is complete, accurate and up-to-date. The information contained in it is however subject to change without notice

More information

Operator s Manual Version 1.21 TR-200. Peristaltic Pump. Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA USA

Operator s Manual Version 1.21 TR-200. Peristaltic Pump. Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA USA Peristaltic Pump TR-200 Operator s Manual Version 1.21 Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA 30087 USA Phone: 800-837-0864 or +1.770.465.7557 Fax: 770.465.7447 e-mail: solutions@durhamgeo.com

More information

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT BT403 A Geno Technology, Inc. (USA) brand name BT-300 Power Supply Cat. No. BT403 1-800-628-7730 1-314-991-6034 info@btlabsystems.com WARNING... 3 SAFETY INFORMATION... 3 ENVIRONMENTAL CONDITIONS... 4

More information

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide Revision 8 THERMO TECHNOLOGIES USDT 2001 Differential Controller Installation and User s Guide USDT 2001 DIFFERENTIAL CONTROLLER Installation and User s Guide Table of Contents Introduction General Information

More information

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors Type range: UN813.3ANI UN813.4ANI UN813.3ANDCB UN813.4ANDCB UN813.5ANI Fig. 1: UN813.3ANI Fig. 2: UN813.4ANI You have selected

More information

Installation, User and Service Manual. Filter Unit WP1-B2-200

Installation, User and Service Manual. Filter Unit WP1-B2-200 Installation, User and Service Manual Filter Unit WP1-B2-200 Disclaimer: All rights reserved. No part of this publication may be reproduced, stored, or transmitted in any form or by any means, without

More information

Installation and Service Instructions for 87,000 Series Manual Adjust Brakes (rev. B)

Installation and Service Instructions for 87,000 Series Manual Adjust Brakes (rev. B) Spring-Set Disc Brakes P/N 8-078-98-06 effective /7/ Installation and Service Instructions for 87,000 Series Manual Adjust Brakes (rev. B) Tools required for installation and servicing: 3/8 hex wrench

More information

NIVOCONT R VIBRATING ROD LEVEL SWITCHES

NIVOCONT R VIBRATING ROD LEVEL SWITCHES For solids NIVOCONT R VIBRATING ROD LEVEL SWITCHES O U R P R O F E S S I O N I S Y O U R L E V E L LEVEL SWITCHES O U R P R O F E S S NIVOCONT R VIBRATING ROD LEVEL SWITCHES MAIN FEATURES Extension up

More information

SERVICE MANUAL (INTERNATIONAL)

SERVICE MANUAL (INTERNATIONAL) SERVICE MANUAL (INTERNATIONAL) IMPINGER CONVEYOR OVENS MODEL 1421-000-E, 1454, 1455 WITH PUSH BUTTON CONTROLS Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States

More information

Warning. Document ref: A October 2015

Warning. Document ref: A October 2015 Sentry Door Curtain Installation, Operation & Maintainance Instructions Dunham-Bush Ltd, Downley Road, Havant, Hampshire, P09 2JD Tel. 023 9247 7700 Email. info@dunham-bush.co.uk Document ref: 128-000-001-A

More information

Service instructions. MAGNA Series 2000

Service instructions. MAGNA Series 2000 Service instructions MAGNA Series 2000 Magna 32-120, 40-120, 50-60, 50-120, 65-60, 65-120 1 phase 50/60 Hz The pump must be serviced by a qualified person. Service must be carried out in accordance with

More information

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work GE Digital Energy Power Quality User Manual Digital Energy Uninterruptible Power Supply ML Series UPS 350-500-700-1000 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno)

More information

Continuous level measuring system NB 3000 Selection list

Continuous level measuring system NB 3000 Selection list Table of contents Page Overview 2 ------------------------------------------------------------------------------------------------------------------- Specifications 3 -------------------------------------------------------------------------------------------------------------------

More information

HOPPER LOADER. Serie ITP. Serie ISP. Serie IPL. Serie IPL-P

HOPPER LOADER. Serie ITP. Serie ISP. Serie IPL. Serie IPL-P HOPPER LOADER Serie ITP Serie ISP Serie IPL Serie IPL-P Hopper Loaders type ITP Suitable for: three-phase version for granulate/regrind filter with large filter surface automatic filter cleaning cycle

More information

P/N Wheeler. user manual

P/N Wheeler. user manual P/N 35000068 Wheeler user manual 1998, 1999 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing from

More information

ARTICLE BEGINNING SERVICE PRECAUTIONS

ARTICLE BEGINNING SERVICE PRECAUTIONS Page 1 of 96 ARTICLE BEGINNING SERVICE PRECAUTIONS WARNING: WARNING: CAUTION: When performing any inspection or service procedure on this vehicle, ensure following service precautions are followed to prevent

More information

SERVICE MANUAL (2)

SERVICE MANUAL (2) Terra 128B - 132B SERVICE MANUAL 146 0721 000(2)2003-04 INDEX GENERAL INFORMATION 3 MACHINE LIFTING 3 MACHINE TRANSPORTATION 3 OTHER AVAILABLE MANUALS 3 SAFETY - ACCIDENT PREVENTION 4 GENERAL SAFETY RULES

More information

Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H

Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H USER NOTE: This addendum serves as additional information for Pulsafeeder PULSAR and PULSAR Shadow metering pumps equipped with

More information

BULK SOLIDS FEEDING. Distributor of. Rotary Valve RV RVR RVR

BULK SOLIDS FEEDING. Distributor of. Rotary Valve RV RVR RVR BULK SOLIDS FEEDING Distributor of Rotary Valve RV RVR RV RVR Rotary Valve RV RVR High filling efficiency and precise metering in gravity feeding and pneumatic conveying of products in powder and granules.

More information

H.S. MACHINERY RING COMPRESSORS

H.S. MACHINERY RING COMPRESSORS OPERATION & PARTS MANUAL Thank you for purchasing an H.S Machinery Limited Regenerative Blower. This product is manufactured under strict ISO-9001-2000 quality control guidelines to ensure your satisfaction.

More information

Installation and Service Instructions for Self Adjust Brakes 82,000 Series

Installation and Service Instructions for Self Adjust Brakes 82,000 Series Spring-Set Disc Brakes P/N 8-078-9-00 effective 0// Installation and Service Instructions for Self Adjust Brakes 8,000 Series Current revision available @ www.rexnord.com/stearns Figure Tools required

More information

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual Raptor user manual 1 mounting bracket 2 swivel lock 3 clamp hole 4 lamp access screws 5 air vents 6 AC input & main fuse 7 cooling fan Thank you for selecting the Martin Raptor. This Martin lighting fixture

More information

Bulk Solids Feeding. Distributor for. Blow-Through Rotary Valves RVS Drop-Through Rotary Valves RVC

Bulk Solids Feeding. Distributor for. Blow-Through Rotary Valves RVS Drop-Through Rotary Valves RVC Bulk Solids Feeding Distributor for Blow-Through Rotary Valves RVS Drop-Through Rotary Valves RVC Blow-Through Rotary Valves RVS Drop-Through Rotary Valves RVC High filling efficiency and precise metering

More information

PNEUMATIC PUMP Series

PNEUMATIC PUMP Series PNEUMATIC PUMP Series 3103... User and Maintenance Manual Original text translation TABLE OF CONTENTS 1. INTRODUCTION 2. GENERAL DESCRIPTION 3. PRODUCT-MACHINE IDENTIFICATION 4. TECHNICAL CHARACTERISTICS

More information

Operating Instructions. International English. CCS Dust Extractor

Operating Instructions. International English. CCS Dust Extractor Operating Instructions International English CCS Dust Extractor Electric Cast Saw Dust Removal System Warnings & Safety Rules WARNING!: THIS EQUIPMENT MUST BE EARTHED! Danger!: Possible explosion hazard

More information

SECTION AIR INTAKE SYSTEM

SECTION AIR INTAKE SYSTEM 09-500.295/ 1 2007AL05 SECTION 09-500.295 AIR INTAKE Air for the engine is taken in through a grille located on the upper-rear, left-hand side of the vehicle. See Figure 1. Air passes through a chamber,

More information

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart

LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. LIQUIDYNAMICS Light Viscosity Bulk Transfer Cart Instruction & Parts Manual This Manual Covers P/N 33271 P/N 33271

More information

Monocellular centrifugal electro-pumps

Monocellular centrifugal electro-pumps Réf. 2100 - O33 / a - 5.95 This manual must be given to the end user LS Monocellular centrifugal electro-pumps Installation and maintenance 1 - GENERAL The LS range of monobloc electro-pump units should

More information

OPERATOR S MANUAL StudPro LiteXI Pin Welder Stud Welding Products, Inc

OPERATOR S MANUAL StudPro LiteXI Pin Welder Stud Welding Products, Inc OPERATOR S MANUAL StudPro LiteXI Pin Welder CONTENTS Description Pages Safety 2 Specifications and Features 3 Product Components 4-5 Screen Operation 6-8 Setup and Welding 9-11 CD Gun Exploded View 12

More information

PROBLEM SOLVING GUIDE ELMECO SLUSH MACHINE MODEL FCM

PROBLEM SOLVING GUIDE ELMECO SLUSH MACHINE MODEL FCM A01 INSTRUCTIONS ON HOW TO READ REFERENCES...2 A10 FEATURES AND TECHNICAL SPECIFICATIONS...3 A15 RECOMMENDED PREVENTIVE MAINTENANCE SPARE PARTS KIT...3 A20 IMPORTANT INFORMATION ON FUNCTIONALITY OF THE

More information

OPERATION, INSTALLATION, & MAINTENANCE MANUAL. Aircon BRS Below-Roof Separator. and. BRV Below-Roof Valve

OPERATION, INSTALLATION, & MAINTENANCE MANUAL. Aircon BRS Below-Roof Separator. and. BRV Below-Roof Valve OPERATION, INSTALLATION, & MAINTENANCE MANUAL for Aircon BRS Below-Roof Separator and BRV Below-Roof Valve Aircon Corporation P.O. Box 80446 2873 Chelsea Avenue Memphis, TN 38108-0446 Telephone: (901)

More information

Operations and Service Manual. X30208 Load Bank

Operations and Service Manual. X30208 Load Bank Operations and Service Manual Read all instructions before using the load bank Contents 1. Components... 3 Total Assembly... 3 2) Specifications... 4 a)... 4 3) Receiving... 5 4) Safety... 5 a) Ground

More information

Installation- and maintenance instruction B20KA/K

Installation- and maintenance instruction B20KA/K Installation- and maintenance instruction B20KA/K 1 171 615 27 05-01 178 091 07 DESCRIPTION COMPONENTS 1. Air intake 2. Scale, nozzle assembly 3. Nozzle assembly adjustment 4. Test nipple 5. Ignition cables

More information

Installation- and maintenance instruction ST120 S75/21

Installation- and maintenance instruction ST120 S75/21 Installation- and maintenance instruction ST120 S75/21 1 171 615 30 05-01 178 058 15 DESCRIPTION Components 1. Reset button 2. Control box 3. Ignition transformer 4. Ignition cables 5. Nozzle assembly

More information

OWNER S MANUAL Please read this manual before operating your power supply

OWNER S MANUAL Please read this manual before operating your power supply AC-DC POWER SUPPLY Switch Mode AC-DC Power Supply Model No. PSU-1210 PSU-1223 PSU-1230 OWNER S MANUAL Please read this manual before operating your power supply Table of Contents Precautions 2 Description

More information

MANUAL D250SA SMARTPASS 120. Input Solar panel Earth Connection

MANUAL D250SA SMARTPASS 120. Input Solar panel Earth Connection MANUAL CONGRATULATIONS on the purchase of your new CTEK charger providing professional battery care. This charger is included in a series of professional chargers from CTEK SWEDEN AB and represents the

More information

Measurements are expressed in millimeters.

Measurements are expressed in millimeters. T-Rex user manual Measurements are expressed in millimeters. 1 Lamp access 2 Focus adjustment 3 Mounting bracket 4 Swivel locks 5 Clamp hole 6 Air vent 190 285 7 AC input & main fuse 8 Microphone 490 164

More information

Installation- and maintenance instruction BENTOFLEX ST120KAV

Installation- and maintenance instruction BENTOFLEX ST120KAV Installation- and maintenance instruction BENTOFLEX ST120KAV 1 171 625 61 05-01 178 001 16 DESCRIPTION COMPONENTS 1. Reset button 2. Control box 3. Ignition transformer 4. Ignition cables 5. Nozzle assembly

More information

Troubleshooting Guide

Troubleshooting Guide Troubleshooting Guide This guide contains information for identifying and correcting issues that may arise. Applicable Models: i200 i200p i250 i250p i200x i201x i250x i251x iq251 iq251d iq751 iq1001 iq1501

More information

The Mobrey product range provides reliable point level detection in a variety of dry solid applications

The Mobrey product range provides reliable point level detection in a variety of dry solid applications Product Data Sheet June 2015 IP400, Rev DG Mobrey Dry Products Level Measurement and Control The Mobrey product range provides reliable point level detection in a variety of dry solid applications The

More information

Installation, Service and Parts List Series 56,800 for Class I & II, Division 2 Manual Adjust Brakes

Installation, Service and Parts List Series 56,800 for Class I & II, Division 2 Manual Adjust Brakes Spring-Set Disc Brakes P/N 8-078-905-8 effective /0/0 Installation, Service and Parts List Series 56,800 for Class I & II, Division Manual Adjust Brakes Tools required for installation and servicing: /8

More information

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007) Installation, Operation and Maintenance Manual (from February 2007) Publication 2698C (GB) 0207 1A 3319 8035B Donaldson reserve the right to alter design without notice. Freedom from patent restrictions

More information

D3000. Troubleshooting Guide

D3000. Troubleshooting Guide Page 1 of 6 17486-00 Rev B s3 April 2009 Contents Description Page Safety.. 3 Introduction 3 Standard External Controls, Indicators and Normal Alarm Conditions 3 Troubleshooting Table.. 4 Unable to program

More information

OPERATOR S MANUAL. TW-i SERIES. Capacitor Discharge Stud Welder. MODELS: TW-i 250 TW-i 250CP TW-i 321 TW-i 375

OPERATOR S MANUAL. TW-i SERIES. Capacitor Discharge Stud Welder. MODELS: TW-i 250 TW-i 250CP TW-i 321 TW-i 375 OPERATOR S MANUAL TW-i SERIES Capacitor Discharge Stud Welder MODELS: TW-i 250 TW-i 250CP TW-i 321 TW-i 375 TRU-WELD EQUIPMENT COMPANY www.truweldstudwelding.com (330) 725-7744 CONTENTS Description Pages

More information

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

Te 803 Electronic Controller. Service, Operation & Technical Information Manual Te 803 Electronic Controller Service, Operation & Technical Information Manual WARNING! Technical descriptions and data given in this document are accurate, to the best of our knowledge, but can be subject

More information

INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS

INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS ROTARY VANE -00% OIL-FREE VACUUM PUMP OR COMPRESSOR 0 to 08 0 to 0 3060 to 3080 C CE RoHS ISO 9000:00 300 to 30 Read through carefully and understand these

More information

COLLECTOR 37 USER MANUAL

COLLECTOR 37 USER MANUAL COLLECTOR 37 USER MANUAL A B E F C D H 2 G ENGLISH INTRODUCTION POWERBOSS,Inc. leaders in the production of sweeping machines, are pleased to welcome you as an owner of the Collector 37 sweeper machine.

More information

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions GRUNDFOS INSTRUCTIONS MTC Installation and operating instructions LIMITED WARRANTY Products manufactured by GRUNDFOS PUMPS CORPORATION (Grundfos) are warranted to the original user only to be free of defects

More information

US - UP2/OIL 12V US - UP2/OIL 24V

US - UP2/OIL 12V US - UP2/OIL 24V SELF PRIMING ELECTRIC PUMP FOR TRANSFERRING LUBRICATING OILS OR VISCOUS FLUIDS INSTRUCTIONS FOR USE 164 220 12-US - UP2/OIL 12V 164 220 13-US - UP2/OIL 24V 15/05/14 Rev.02 A PRODUCT DESCRIPTION Self-priming

More information

Electric Fuel Pump FPM

Electric Fuel Pump FPM INSTRUCTION MANUAL Electric Fuel Pump FPM S1590, Rev B LISTED MOTOR FPM-12, FPM-12/HF, FPM-24, FPM-115, FPM-220 Congratulations on purchase of this World Class Electric Fuel Pump! Pump Outlet Elbow Nozzle

More information

Installation and Operating Instruction for Brake Caliper HW 150 HFA and HW 180 HFA E e

Installation and Operating Instruction for Brake Caliper HW 150 HFA and HW 180 HFA E e Installation and Operating Instruction for Brake Caliper HW 150 HFA and HW 180 HFA E 09.736e Schaberweg 30-38 Phone +49 6172 275-0 61348 Bad Homburg Fax +49 6172 275-275 Germany www.ringspann.com info@ringspann.com

More information

16000SIII Automatic Grease System

16000SIII Automatic Grease System Manual # 99905495 16000SIII Automatic Grease System Effective 20120716 IOWA MOLD TOOLING CO., INC. PO Box 189 Garner, IA 50438 Tel: 641-923-3711 FAX: 641-923-2424 Website: http://www.imt.com Copyright

More information

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web:  - MAKING MODERN LIVING POSSIBLE Quick Setup VLT FCM 300 Series Factory setting Motors type B14 & B34 mounting Reset (pushbutton) Start Jog Speed reference Fig. 1 - Reset to be closed short time for resetting

More information

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver. Advantage-D Series 3 Central Vacuum Systems (Expandable/Modular Models) (Ver. 8/05) Operating Instructions and Maintenance Manual DESCRIPTION The Becker Advantage-D and Advantage-L central vacuum systems

More information

Order Number MOP C2. Microwave Oven

Order Number MOP C2. Microwave Oven Order Number MOP0107026C2 Microwave Oven 2 2001 Matsushita Electric Industrial Co., Ltd. All rights reserved. Unauthorized copying and distribution is a violation of law. 1 Inverter Warning The inverter

More information

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option HT-10000 Dielectric Withstand Tester 0-10000 Volts AC Output 25mA Leakage Option Instruction Manual COMPLIANCE WESTUSA Dear Customer: Congratulations! Compliance West USA is proud to present you with your

More information

Installation- and maintenance instruction B80-2/3

Installation- and maintenance instruction B80-2/3 Installation- and maintenance instruction B80-2/3 1 171 625 22 05-01 178 002 64 DESCRIPTION COMPONENTS 1. Flame cone 2. Shrouded disc 3. Nozzle 4. Nozzle assembly 5. Ignition electrodes 6. Ignition cable

More information

Operation Manual Model: PPSSS Submersible Slurry Pump

Operation Manual Model: PPSSS Submersible Slurry Pump ABN 17 154 031 802 21 Ginger St, Paget Mackay Qld Australia 4740 PO Box 5709, Mackay Mail Centre Qld Australia 4741 Ph: +61 07 4998 5070 Fax: +61 07 4952 1944 Mobile: +61 0409 827 290 Email: admin@pricepumpsaustralia.com.au