Level Measurement Point level measurement - RF Capacitance switches

Size: px
Start display at page:

Download "Level Measurement Point level measurement - RF Capacitance switches"

Transcription

1 Pointek CLS300 - Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. Benefits Active-Shield technology so measurement is unaffected by material buildup or nozzle interference in active shield section Performs in extremely abrasive conditions because of solid rod construction Three LED indicators for adjustment control, output status, and power High-temperature version up to 00 C (752 ) Keep unit out of path of falling material, or protect probe from falling material. Build up of material in active shield area does not affect switch operation. Application Pointek CLS300 standard version has three LED indicators with basic relay and solid-state switch alarms. The robust design of CLS300 makes it specifically applicable for heavy solids applications where abrasive materials occur as in the mining industry. The fully potted electronics are unaffected by condensation, dust or vibration. Wetted parts are made of stainless steel with a PA shield for high chemical resistance, and of ceramic and stainless steel for high temperature version. Materials with low or high dielectric constants can be accurately detected. The unique Active Shield suppresses interference from material buildup or long installation nozzles. The unique modular design of the Pointek CLS300 provides a wide range of configurations, process connections, extensions and approvals to meet the temperature and pressure requirements of specific applications. The modular design makes ordering easier and reduces stocking requirements. A wide range of probe configurations are available, including rod and cable versions. Key Applications: liquids, slurries, bulk solids, relatively high pressure and temperature, hazardous areas, milling and mining applications Install probe at least 50 (2) from tank wall. Note angle of repose and adjust accordingly. Pointek CLS300 installation, dimensions in mm (inch) Min. 50 (2) Min. 50 (2) /2 Siemens I 0 Update /207

2 Pointek CLS300 - Standard Technical specifications Mode of operation Measuring principle Inverse frequency shift capacitive level detection Input Measured variable Change in picoarad (p) Output Output signal Relay output SPDT orm C relay - Max. contact voltage 30 V DC 250 V AC - Max. contact current 5 A (DC) 8 A (AC) - Max. switching capacity 50 W (DC) VA (AC) - Time delay (ON and/or O) s Solid-state output -Output alvanically isolated -Protection Against reversed polarity (bipolar) - Max. switching voltage 30 V (DC) 30 V peak (AC) - Max. load current 82 ma - Voltage drop < V, typical at 50 ma - Time delay (pre or post switching) s Accuracy Resolution Min. sensitivity (p) % change in actual capacitance Max. temperature error 0.2 % of actual capacitance value Rated operating conditions ) Installation conditions Location Indoor/outdoor Ambient conditions Ambient temperature C ( ) 2) Medium conditions Liquids, bulk solids, slurries and interfaces, and applications with viscous materials Relative dielectric constant r Min..5 Process temperature - Rod/Cable version C ( ) 2) - High-temperature version C ( ) Process pressure 3) bar g ( psi g) Design Material (enclosure) Degree of Protection Cable inlet Controls and displays Displays Potentiometers Switches Power supply Supply Certificates and approvals eneral Purpose lameproof Enclosure with IS Probe Powder-coated aluminum with gasket Standard: Type /NEMA /IP65 Optional: Type /NEMA /IP68 2 x M20 x.5 thread (option: 2 x ½" NPT conduit entry including plugged entry) 3 LEDs, for probe status, output status and power supply 2 potentiometers for time delay and sensitivity 5 DIP switches for delay on/off, failsafe high/low, time delay test/adjust, high/low sensitivity, test delay settings V AC/DC, Hz, galvanically isolated, 2 W CSA, M, CE, RCM ATEX II /2 EEx d[ia] IIC T6... T ATEX II /2 D T00 C Dust Ignition Proof with IS Probe ATEX II /2 D T00 C CSA/M Class II, Div., roups E,, CSA/M Class III T Explosion Proof Enclosure with IS Probe Marine Overfill Protection Others CSA/M Class I, Div., roups A, B, C, D CSA/M Class II, Div., roups E,, CSA/M Class III T Lloyds Register of Shipping, Categories ENV, ENV2, and ENV5 WH (ermany) VLAREM II (Belgium) Pattern Approval (China) ) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves starting on page /56. 2) Thermal isolator is used if process connection temperature exceeds 85 C (85 ). 3) Pressure rating of process seal is temperature dependent. See Pressure/Temperature curves starting on page /56. Design: Probe Length Sensor wetted parts Rod version High Temperature version Cable version Min. 250 mm (9.8 inch), max. 000 mm (0 inch) PA (no insulation on active probe), 36L stainless steel, PEEK isolators Min. 250 mm (9.8 inch), max. 000 mm (0 inch) Ceramic (ZrO ) 2 ) isolators (no insulation on active probe), 36L stainless steel Min. 000 mm (0 inch), max mm (98 inch) 36 stainless steel, optional PA, PEEK isolators O-ring seal material KM (optional KM) 2) raphite 2) KM (optional KM) 2) Thermal isolator Optional Standard Optional Extension User selectable length User selectable length User selectable cable length ) Zirconium Oxide 2) or caustic materials, consult a local sales person for alternative O-rings. or more information, please visit Siemens I 0 Update /207 /3

3 Pointek CLS300 - Standard Pointek CLS300 - Standard - Rod Version with Threaded or langed process connection 7ML choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present, and has the ability to tune out buildup on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 36L stainless steel ¾" NPT [(Taper), ANSI/ASME B.20.] 0 A " NPT [(Taper), ANSI/ASME B.20.] 0 B ¼" NPT [(Taper), ANSI/ASME B.20.] 0 C ½" NPT [(Taper), ANSI/ASME B.20.] 0 D R ¾" [(BSPT), EN 0226/PT (JIS-T), JIS B 0203] A R " [(BSPT), EN 0226/PT (JIS-T), JIS B 0203] B R ½" [(BSPT), EN 0226/PT (JIS-T), D JIS B 0203] ¾" [(BSPP), EN ISO 228-/P (JIS-P), 3 A " [(BSPP), EN ISO 228-/P (JIS-P), 3 B ½" [(BSPP), EN ISO 228-/P (JIS-P), 3 D Welded flange, 36L stainless steel, raised face " ASME, 50 lb 5 A " ASME, 300 lb 5 B " ASME, 600 lb 5 C ½" ASME, 50 lb 5 D ½" ASME, 300 lb 5 E ½" ASME, 600 lb 5 2" ASME, 50 lb 5 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 50 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 50 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 36L stainless steel, Type A flat faced DN 25, PN 6 6 A DN 25, PN 0 6 B DN 0, PN 6 6 C DN 0, PN 0 6 D DN 50, PN 6 6 E DN 50, PN 0 6 DN 80, PN 6 6 DN 80, PN 0 6 H DN 00, PN 6 6 J DN 00, PN 0 6 K (Note: flange bolting patterns and facings dimensionally correspond to the applicable ASME B6.5 or EN 092- standard.) Probe length (length from flange face) (threaded lengths include process thread) Note: No Y0 needed in Order code for standard lengths Standard version, rod 350 mm (3.78 inch) A Extended rod, length 500 mm (9.69 inch) B Extended rod, length 750 mm (29.53 inch) C Extended rod, length 000 mm (39.37 inch) D Pointek CLS300 - Standard - Rod Version 7ML5650- with Threaded or langed process connection choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present, and has the ability to tune out buildup on the probe. Add Order code Y0 and plain text: "Insertion length... mm" E mm ( inch) mm ( inch) mm ( inch) Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection temperatures over 85 C (85 )] Wetted seals KM 0 KM [for process temperatures above -20 C (- )] Probe material 36L stainless steel with PA lining and PEEK 0 isolators Approvals Dust Ignition Proof with IS Probe: C CE, RCM, ATEX II /2 D T00 C lameproof Enclosure with IS Probe: D CE, RCM, ATEX II /2 EEx d[ia] IIC T6... T, ATEX II /2 D T00 C lameproof Enclosure with IS Probe, E with WH approval: CE, RCM, ATEX II /2 EEx d[ia] IIC T6... T, ATEX II /2 D T00 C Dust Ignition Proof with IS Probe: CSA/M Class II, Div., roups E,, CSA/M Class III T Explosion Proof Enclosure with IS Probe: CSA/M Class I, Div., roups A, B, C, D CSA/M Class II, Div., roups E,, CSA/M Class III T eneral Purpose (CSA, M) H eneral Purpose (CE, RCM) J eneral Purpose with WH approval K (CSA, M, CE, RCM) Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20 x.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20 x.5 cable inlet, IP68 D Active shield length Standard length - 0 (25 mm threaded, 05 mm flanged) (250 mm threaded, 230 mm flanged) ) 2 (00 mm threaded, 380 mm flanged) 2) ) Available with Probe version options B... D,, only [ 500 mm (9.69 inch)] 2) Available with Probe version options C, D, and only [ 750 mm (29.53 inch)] / Siemens I 0 Update /207

4 Pointek CLS300 - Standard Order code urther designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y0 in plain text description Stainless steel tag [70 x 3 mm (2.75 x 0.5 inch)]: Y5 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C Part 8 and to ISO 9000 Material Inspection Certificate Type 3. per C2 EN 020 Operating Instructions All literature is available to download for free, in a range of languages, at processinstrumentation/documentation Accessories See page /55 Pointek CLS300 - Standard - Cable Version 7ML565- with Threaded or langed process connection choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present, and has the ability to tune out buildup on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 36L stainless steel ¼" NPT [(Taper), ANSI/ASME B.20.] 0 C ½" NPT [(Taper), ANSI/ASME B.20.] 0 D R ½" [(BSPT), EN 0226/PT (JIS-T), D JIS B 0203] ½" [(BSPP), EN ISO 228-/P (JIS-P), 3 D Welded flange, 36L stainless steel, raised face ½" ASME, 50 lb 5 D ½" ASME, 300 lb 5 E ½" ASME, 600 lb 5 2" ASME, 50 lb 5 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 50 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 50 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 36L stainless steel, Type A flat faced DN 0, PN 6 6 C DN 0, PN 0 6 D DN 50, PN 6 6 E DN 50, PN 0 6 DN 80, PN 6 6 DN 80, PN 0 6 H DN 00, PN 6 6 J DN 00, PN 0 6 K (Note: lange bolting patterns and facings dimensionally correspond to the applicable ASME B6.5 or EN 092- standard.) Probe length (length from flange face) (threaded lengths include process thread) Note: No Y0 needed in Order code for standard lengths Extended cable, mm (8. inch), A length can be shortened by customer Extended cable, mm ( inch), B length can be shortened by customer Add Order code Y0 and plain text: "Insertion length... mm" Extended cable, mm E ( inch) Extended cable, mm ( inch) Extended cable, mm ( inch) Extended cable, mm H ( inch) Extended cable, mm J ( inch) Extended cable, mm K ( inch) Siemens I 0 Update /207 /5

5 Pointek CLS300 - Standard Pointek CLS300 - Standard - Cable Version with Threaded or langed process connection choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present, and has the ability to tune out buildup on the probe. 7ML Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection temperatures over 85 C (85 )] Wetted seals KM 0 KM [for process temperatures above -20 C (- )] Probe material Bare 36L stainless steel cable, PEEK isolators and 0 36L stainless steel cable weight PA coated cable, PEEK isolators and 36L stainless steel cable weight Approvals Dust Ignition Proof with IS Probe: C CE, RCM, ATEX II /2 D T00 C lameproof Enclosure with IS Probe: D CE, RCM, ATEX II /2 EEx d[ia] IIC T6... T, ATEX II /2 D T00 C lameproof Enclosure with IS Probe, E with WH approval: CE, RCM, ATEX II /2 EEx d[ia] IIC T6... T, ATEX II /2 D T00 C Dust Ignition Proof with IS Probe: CSA/M Class II, Div., roups E,, CSA/M Class III T Explosion Proof Enclosure with IS Probe: CSA/M Class I, Div., roups A, B, C, D CSA/M Class II, Div., roups E,, CSA/M Class III T eneral Purpose (CSA, M) H eneral Purpose (CE, RCM) J eneral Purpose with WH approval K (CSA, M, CE, RCM) Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20 x.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20 x.5 cable inlet, IP68 D Active shield length Standard length - 0 (25 mm threaded, 05 mm flanged) (250 mm threaded, 230 mm flanged) 2 (00 mm threaded, 380 mm flanged) ) ) Available with Probe version options A, B,... K, only [ 000 mm (39.7 inch)]. Order code urther designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y0 in plain text description Stainless steel tag [70 x 3 mm (2.75 x 0.5 inch)]: Y5 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C Part 8 and to ISO 9000 Material Inspection Certificate Type 3. per C2 EN 020 Operating Instructions All literature is available to download for free, in a range of languages, at processinstrumentation/documentation Accessories See page /55 /6 Siemens I 0 Update /207

6 Pointek CLS300 - Standard Pointek CLS300 - Standard - High Temperature Rod Version with Threaded or langed process connection 7ML choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present, and has the ability to tune out buildup on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 36L stainless steel ¾" NPT [(Taper), ANSI/ASME B.20.] 0 A " NPT [(Taper), ANSI/ASME B.20.] 0 B ¼" NPT [(Taper), ANSI/ASME B.20.] 0 C ½" NPT [(Taper), ANSI/ASME B.20.] 0 D R ¾" [(BSPT), EN 0226/PT (JIS-T), JIS B 0203] A R " [(BSPT), EN 0226/PT (JIS-T), JIS B 0203] B R ½" [(BSPT), EN 0226/PT (JIS-T), D JIS B 0203] ¾" [(BSPP), EN ISO 228-/P (JIS-P), 3 A " [(BSPP), EN ISO 228-/P (JIS-P), 3 B ½" [(BSPP), EN ISO 228-/P (JIS-P), 3 D Welded flange, 36L stainless steel, raised face " ASME, 50 lb 5 A " ASME, 300 lb 5 B " ASME, 600 lb 5 C ½" ASME, 50 lb 5 D ½" ASME, 300 lb 5 E ½" ASME, 600 lb 5 2" ASME, 50 lb 5 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 50 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 50 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 36L stainless steel, Type A flat faced DN 25, PN 6 6 A DN 25, PN 0 6 B DN 0, PN 6 6 C DN 0, PN 0 6 D DN 50, PN 6 6 E DN 50, PN 0 6 DN 80, PN 6 6 DN 80, PN 0 6 H DN 00, PN 6 6 J DN 00, PN 0 6 K (Note: lange bolting patterns and facings dimensionally correspond to the applicable ASME B6.5 or EN 092- standard.) Probe length (length from flange face) (threaded lengths include process thread) Note: No Y0 needed in Order code for standard lengths Standard version rod, 350 mm (3.78 inch) A Extended rod, length 500 mm (9.69 inch) B Extended rod, length 750 mm (29.53 inch) C Extended rod, length 000 mm (39.37 inch) D Pointek CLS300 - Standard - High Temperature 7ML5652- Rod Version with Threaded or langed process connection choices and configurable output. CLS300 is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present, and has the ability to tune out buildup on the probe. Add Order code Y0 and plain text: "Insertion length... mm" E mm ( inch) mm ( inch) mm ( inch) Wetted seals raphite 0 Probe material 36L stainless steel with ceramic (ZrO 2 ) isolators 0 Approvals Dust Ignition Proof with IS Probe: C CE, RCM, ATEX II /2 D T00 C lameproof Enclosure with IS Probe: D CE, RCM, ATEX II /2 EEx d[ia] IIC T6... T, ATEXII /2 D T00 C lameproof Enclosure with IS Probe, E with WH approval: CE, RCM, ATEX II /2 EEx d[ia] IIC T6... T, ATEX II /2 D T00 C Dust Ignition Proof with IS Probe: CSA/M Class II, Div., roups E,, CSA/M Class III T Explosion Proof Enclosure with IS Probe: CSA/M Class I, Div., roups A, B, C, D CSA/M Class II, Div., roups E,, CSA/M Class III T eneral Purpose (CSA, M) H eneral Purpose (CE, RCM) J eneral Purpose with WH approval K (CSA, M, CE, RCM) Enclosure and lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20 x.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20 x.5 cable inlet, IP68 D Active shield length Standard length - 0 (25 mm threaded, 05 mm flanged) (250 mm threaded, 230 mm flanged) ) 2 (00 mm threaded, 380 mm flanged) 2) ) Available with Probe version options B... D,, only [ 500 mm (9.69 inch)] 2) Available with Probe version options C, D, and only [ 750 mm (29.53 inch)] Siemens I 0 Update /207 /7

7 Pointek CLS300 - Standard Order code urther designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y0 in plain text description ) Stainless steel tag [70 x 3 mm (2.75 x 0.5 inch)]: Y5 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C Part 8 and to ISO 9000 Material Inspection Certificate Type 3. per C2 EN 020 Operating Instructions All literature is available to download for free, in a range of languages, at processinstrumentation/documentation Accessories See page /55 ) Not available with Probe length option B. /8 Siemens I 0 Update /207

8 Pointek CLS300 - Digital Overview Configuration Installation Pointek CLS300 (digital version) is an inverse frequency shift capacitance level and material detection switch with optional rod/cable choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. The digital version includes PROIBUS PA, an LCD display, and advanced diagnostic features. Benefits Active-Shield technology so measurement is unaffected by material buildup or nozzle interference in active shield section Performs in extremely abrasive conditions because of solid rod construction Push-button calibration, full-function diagnostics High sensitivity allows installation in a wide range of liquids, solids or slurry applications Integral LCD display allows for easy menu-driven setup PROIBUS PA communication (SIMATIC PDM compatible) Keep unit out of path of falling material, or protect probe from falling material. Build up of material in active shield area does not affect switch operation. Application Pointek CLS300 digital version provides an integral LCD display for stand-alone use, with PROIBUS PA communication (Profile version 3.0, Class B) when required. Solid-state switch alarm is standard. The robust design of CLS300 makes it specifically applicable for heavy solids applications where abrasive materials occur as in the mining industry. The fully potted electronics are unaffected by condensation, dust or vibration. Wetted parts are made of stainless steel with a PA shield for high chemical resistance, and of ceramic and stainless steel for high temperature version. Materials with low or high dielectric constants can be accurately detected. The unique Active Shield suppresses interference from material buildup or long installation nozzles. The unique modular design of the Pointek CLS300 provides a wide range of configurations, process connections, extensions and approvals to meet the temperature and pressure requirements of specific applications. The modular design makes ordering easier and reduces stocking requirements. A wide range of probe configurations are available, including rod and cable versions. Key Applications: liquids, slurries, bulk solids, relatively high pressure and temperature, hazardous areas, milling and mining applications Install probe at least 50 (2) from tank wall. Note angle of repose and adjust accordingly. Pointek CLS300 installation, dimensions in mm (inch) Min. 50 (2) Min. 50 (2) Siemens I 0 Update /207 /9

9 Pointek CLS300 - Digital Technical specifications Mode of operation Measuring principle Inverse frequency shift capacitive level detection Input Measured variable Change in picoarad (p) Output Solid-state output Output alvanically isolated Protection Against reversed polarity (bipolar) Max. switching voltage 30 V (DC) 30 V peak (AC) Max. load current 82 ma Voltage drop < V, typical at 50 ma Time delay (pre or post switching) Programmable by user ( s) ail-safe mode Min. or max. Connection Removable terminal block Accuracy Resolution Min. sensitivity (p) % change in actual capacitance Max. temperature error 0.2 % of actual capacitance value Rated operating conditions ) Installation conditions Location Indoor/outdoor Ambient conditions Ambient temperature C ( ) 2) Medium conditions Liquids, bulk solids, slurries, interfaces, and applications with viscous materials Relative dielectric constant r Min..5 Process temperature - Rod/Cable version C ( ) 2) - High Temperature version C ( ) Process pressure 3) bar g ( psi g) Design Material (enclosure) Powder-coated aluminum with gasket Degree of protection Standard: Type /NEMA /IP65 Optional: Type /NEMA /IP68 Cable inlet 2 x M20 x.5 thread (option: 2 x ½" NPT conduit entry including plugged entry) Controls and displays Local display LCD Configuration Locally, using 3 button keypad (for standalone operation) Remotely, using SIMATIC PDM (for installation on a network) Power supply Bus voltage (at process connection) Standard: V DC Intrinsically Safe: V DC 2.5 ma Current consumption Certificates and approvals eneral Purpose CSA, M, CE, RCM Dust Ignition Proof ATEX II /2 D, 2 D IP6X T00 C lameproof Enclosure With IS Probe ATEX II /2 EEx d[ia] IIC T6... T ATEX II /2 D T00 C Dust Ignition Proof With IS Probe CSA/M Class II, Div., roups E,, CSA/M Class III T Intrinsically Safe ) ATEX II EEx ia IIC T6... T ATEX II /2 D, 2 D IP6X T00 C CSA/M Class I, Div., roups A, B, C, D CSA/M Class II, Div., roups E,, CSA/M Class III T Non-incendive CSA/M Class I, Div. 2, roups A, B, C, D CSA/M Class II, Div. 2, roups, CSA/M Class III T or T6 Explosion Proof with IS Probe CSA/M Class I, Div., roups A, B, C, D CSA/M Class II, Div., roups E,, CSA/M Class III T Marine Lloyds Register of Shipping, Categories ENV, ENV2, and ENV5 Others Pattern Approval (China) Communication PROIBUS PA (IEC 658 CP3 CP3/2) Bus physical layer: IEC MBP-(IS) Device profile: PROIBUS PA profile for Process Control Devices Version 3.0, Class B ISCO field device ) When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves starting on page /56. 2) Thermal isolator is used if process connection temperature exceeds 85 C (85 ) 3) Pressure rating of process seal is temperature dependent. See Pressure/Temperature curves starting on page /56. ) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection Design: Probe Length Sensor wetted parts Rod version High Temperature version Cable version Min. 250 mm (9.8 inch), max. 000 mm (0 inch) PA (no insulation on active probe), 36L stainless steel, PEEK isolators Min. 250 mm (9.8 inch), max. 000 mm (0 inch) Ceramic (ZrO ) 2 ) isolators (no insulation on active probe), 36L stainless steel Min. 000 mm (0 inch), max mm (98 inch) 36 stainless steel, optional PA, PEEK isolators O-ring seal material KM (optional KM) 2) raphite 2) KM (optional KM) 2) Thermal isolator Optional Standard Optional Extension User selectable length User selectable length User selectable cable length ) Zirconium Oxide 2) or caustic materials, consult a local sales person for alternative O-rings. or more information, please visit /50 Siemens I 0 Update /207

10 Pointek CLS300 - Digital Pointek CLS300 - Digital - Rod with Threaded or langed process connection 7ML choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 36L stainless steel ¾" NPT [(Taper), ANSI/ASME B.20.] 0 A " NPT [(Taper), ANSI/ASME B.20.] 0 B ¼" NPT [(Taper), ANSI/ASME B.20.] 0 C ½" NPT [(Taper), ANSI/ASME B.20.] 0 D R ¾" [(BSPT), EN 0226/PT (JIS-T), JIS B 0203] A R " [(BSPT), EN 0226/PT (JIS-T), JIS B 0203] B R ½" [(BSPT), EN 0226/PT (JIS-T), D JIS B 0203] ¾" [(BSPP), EN ISO 228-/P (JIS-P), 3 A " [(BSPP), EN ISO 228-/P (JIS-P), 3 B ½" [(BSPP), EN ISO 228-/P (JIS-P), 3 D Welded flange, 36L stainless steel, raised face " ASME, 50 lb 5 A " ASME, 300 lb 5 B " ASME, 600 lb 5 C ½" ASME, 50 lb 5 D ½" ASME, 300 lb 5 E ½" ASME, 600 lb 5 2" ASME, 50 lb 5 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 50 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 50 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 36L stainless steel, Type A flat faced DN 25, PN 6 6 A DN 25, PN 0 6 B DN 0, PN 6 6 C DN 0, PN 0 6 D DN 50, PN 6 6 E DN 50, PN 0 6 DN 80, PN 6 6 DN 80, PN 0 6 H DN 00, PN 6 6 J DN 00, PN 0 6 K (Note: lange bolting patterns and facings dimensionally correspond to the applicable ASME B6.5 or EN 092- standard.) Probe length (length from flange face) (threaded lengths include process thread) Note: No Y0 needed in Order code for standard lengths Standard version, rod 350 mm (3.78 inch) A Extended rod, length 500 mm (9.69 inch) B Extended rod, length 750 mm (29.53 inch) C Extended rod, length 000 mm (39.37 inch) D Pointek CLS300 - Digital - Rod with 7ML5660- Threaded or langed process connection choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. Add Order code Y0 and plain text: "Insertion length... mm" E mm ( inch) mm ( inch) mm ( inch) Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection temperatures over 85 C (85 )] Wetted seals KM 0 KM [for process temperatures above -20 C (- )] Probe material 36L stainless steel with PA lining and PEEK 0 isolators Approvals Dust Ignition Proof: B CE, RCM, ATEX II /2 D, 2 D IP6X T00 C Intrinsically Safe ) C CE, RCM, ATEX II EEx ia IIC T6... T, ATEX II /2 D, 2 D IP6X T00 C lameproof Enclosure with IS Probe: D CE, RCM, ATEX II /2 EEx d[ia] IIC T6... T, ATEX II /2 D T00 C Dust Ignition Proof with IS Probe: E CSA/M Class II, Div., roups E,, CSA/M Class III T Intrinsically Safe ) CSA/M Class I, Div., roups A, B, C, D CSA/M Class II, Div., roups E,, CSA/M Class III T Explosion Proof Enclosure with IS Probe: CSA/M Class I, Div., roups A, B, C, D CSA/M Class II, Div., roups E,, CSA/M Class III T eneral Purpose (CSA, M) H eneral Purpose (CSA, M, CE, RCM) J Siemens I 0 Update /207 /5

11 Pointek CLS300 - Digital Pointek CLS300 - Digital - Rod with 7ML5660- Threaded or langed process connection choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. Enclosure and Lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20 x.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20 x.5 cable inlet, IP68 D Active shield length Standard length - 0 (25 mm threaded, 05 mm flanged) (250 mm threaded, 230 mm flanged) 2) 2 (00 mm threaded, 380 mm flanged) 3) )Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection 2) Available with Probe version options B... D,, only [ 500 mm (9.69 inch)] 3) Available with Probe version options C, D, and only [ 750 mm (29.53 inch)] Order code urther designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y0 in plain text description Stainless steel tag [70 x 3 mm (2.75 x 0.5 inch)]: Y5 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C Part 8 and to ISO 9000 Material inspection Certificate Type 3. per C2 EN 020 Operating Instructions All literature is available to download for free, in a range of languages, at processinstrumentation/documentation Accessories See page /55 Pointek CLS300 - Digital - Cable with 7ML566- Threaded or langed process connection choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 36L stainless steel ¼" NPT [(Taper), ANSI/ASME B.20.] 0 C ½" NPT [(Taper), ANSI/ASME B.20.] 0 D R ½" [(BSPT), EN 0226/PT (JIS-T), JIS B 0203] D ½" [(BSPP), EN ISO 228-/P (JIS-P), 3 D Welded flange, 36L stainless steel, raised face ½" ASME, 50 lb 5 D ½" ASME, 300 lb 5 E ½" ASME, 600 lb 5 2" ASME, 50 lb 5 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 50 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 50 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 36L stainless steel, Type A flat faced DN 0, PN 6 6 C DN 0, PN 0 6 D DN 50, PN 6 6 E DN 50, PN 0 6 DN 80, PN 6 6 DN 80, PN 0 6 H DN 00, PN 6 6 J DN 00, PN 0 6 K (Note: lange bolting patterns and facings dimensionally correspond to the applicable ASME B6.5 or EN 092- standard.) Probe length (length from flange face) (threaded lengths include process thread) Note: No Y0 needed in Order code for standard lengths Extended cable, mm (8. inch), A length can be shortened by customer Extended cable, mm ( inch), B length can be shortened by customer Add Order code Y0 and plain text: "Insertion length... mm" Extended cable, mm E ( inch) Extended cable, mm ( inch) Extended cable, mm ( inch) Extended cable, mm H ( inch) Extended cable, mm J ( inch) Extended cable, mm K ( inch) /52 Siemens I 0 Update /207

12 Pointek CLS300 - Digital Pointek CLS300 - Digital - Cable with 7ML566- Threaded or langed process connection choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. Thermal isolator Without thermal isolator 0 With thermal isolator [for process connection temperatures over 85 C (85 )] Wetted seals KM 0 KM [for process temperatures above -20 C (- )] Probe material Bare 36L stainless steel cable, PEEK isolators and 0 36L stainless steel cable weight PA coated cable, PEEK isolators and 36L stainless steel cable weight Approvals Dust Ignition Proof: B CE, RCM, ATEX II /2 D, 2 D IP6X T00 C Intrinsically Safe ) C CE, RCM, ATEX II EEx ia IIC T6... T, ATEX II /2 D, 2 D IP6X T00 C lameproof Enclosure with IS Probe: D CE, RCM, ATEX II /2 EEx d[ia] IIC T6... T, ATEX II /2 D T00 C Intrinsically Safe ) CSA/M Class I, Div., roups A, B, C, D CSA/M Class II, Div., roups E,, CSA/M Class III T Explosion Proof Enclosure with IS Probe: CSA/M Class I, Div., roups A, B, C, D CSA/M Class II, Div., roups E,, CSA/M Class III T eneral Purpose (CSA, M) H eneral Purpose (CSA, M, CE, RCM) J Enclosure and Lid Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP65 A 2 x M20 x.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20 x.5 cable inlet, IP68 D Active shield length Standard length - 0 (25 mm threaded, 05 mm flanged) (250 mm threaded, 230 mm flanged) 2 (00 mm threaded, 380 mm flanged) 2) ) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection. 2) Available with Probe version options A, B,... K, only [ 000 mm (39.7 inch)]. Order code urther designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y0 in plain text description Stainless steel tag [70 x 3 mm (2.75 x 0.5 inch)]: Y5 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C Part 8 and to ISO 9000 Material inspection Certificate Type 3. per C2 EN 020 Operating Instructions All literature is available to download for free, in a range of languages, at processinstrumentation/documentation Accessories See page /55 Siemens I 0 Update /207 /53

13 Pointek CLS300 - Digital Pointek CLS300 - Digital - High Temperature Rod version with Threaded or langed process connection choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. Click on the for the online configuration in the PIA Life Cycle Portal. Process connection Threaded, 36L stainless steel ¾" NPT [(Taper), ANSI/ASME B.20.] 0 A " NPT [(Taper), ANSI/ASME B.20.] 0 B ¼" NPT [(Taper), ANSI/ASME B.20.] 0 C ½" NPT [(Taper), ANSI/ASME B.20.] 0 D R ¾" [(BSPT), EN 0226/PT (JIS-T), JIS B 0203] A R " [(BSPT), EN 0226/PT (JIS-T), JIS B 0203] B R ½" [(BSPT), EN 0226/PT (JIS-T), JIS B 0203] ¾" [(BSPP), EN ISO 228-/P (JIS-P), " [(BSPP), EN ISO 228-/P (JIS-P), ½" [(BSPP), EN ISO 228-/P (JIS-P), Welded flange, 36L stainless steel, raised face " ASME, 50 lb 5 A " ASME, 300 lb 5 B " ASME, 600 lb 5 C ½" ASME, 50 lb 5 D ½" ASME, 300 lb 5 E ½" ASME, 600 lb 5 2" ASME, 50 lb 5 2" ASME, 300 lb 5 H 2" ASME, 600 lb 5 J 3" ASME, 50 lb 5 K 3" ASME, 300 lb 5 L 3" ASME, 600 lb 5 M " ASME, 50 lb 5 N " ASME, 300 lb 5 P " ASME, 600 lb 5 Q Welded flange, 36L stainless steel, Type A flat faced DN 25, PN 6 DN 25, PN 0 DN 0, PN 6 DN 0, PN 0 DN 50, PN 6 DN 50, PN 0 DN 80, PN 6 DN 80, PN 0 DN 00, PN 6 DN 00, PN 0 (Note: lange bolting patterns and facings dimensionally correspond to the applicable ASME B6.5 or EN 092- standard.) Probe length (length from flange face) (threaded lengths include process thread) Note: No Y0 needed in Order code for standard lengths Standard version rod, 350 mm (3.78 inch) Extended rod, length 500 mm (9.69 inch) Extended rod, length 750 mm (29.53 inch) Extended rod, length 000 mm (39.37 inch) 7ML D 3 A 3 B 3 D 6 A 6 B 6 C 6 D 6 E H 6 J 6 K A B C D Pointek CLS300 - Digital - High Temperature Rod version with Threaded or langed process connection choices and configurable output. It is ideal for detecting liquids, solids, slurries, foam, and interfaces in demanding conditions where high pressure and temperatures are present and has the ability to tune out buildup on the probe. Add Order code Y0 and plain text: "Insertion length... mm" mm ( inch) mm ( inch) mm ( inch) Wetted seals raphite 0 Probe material 36L stainless steel with ceramic (ZrO 2 ) isolators 0 Approvals Dust Ignition Proof: CE, RCM, ATEX II /2 D, 2 D IP6X T00 C Intrinsically Safe ) CE, RCM, ATEX II EEx ia IIC T6... T, ATEX II /2 D, 2 D IP6X T00 C lameproof Enclosure with IS Probe: CE, RCM, ATEX II /2 EEx d[ia] IIC T6... T, ATEX II /2 D T00 C Intrinsically Safe ) CSA/M Class I, Div., roups A, B, C, D CSA/M Class II, Div., roups E,, CSA/M Class III T Explosion Proof Enclosure with IS Probe: CSA/M Class I, Div., roups A, B, C, D CSA/M Class II, Div., roups E,, CSA/M Class III T eneral Purpose (CSA, M) eneral Purpose (CSA, M, CE, RCM) Enclosure and Lid Aluminum epoxy coated 7ML x ½" NPT via adapter - cable inlet, IP65 A 2 x M20 x.5 cable inlet, IP65 B 2 x ½" NPT via adapter - cable inlet, IP68 C 2 x M20 x.5 cable inlet, IP68 D Active shield length Standard length - 0 (25 mm threaded, 05 mm flanged) (250 mm threaded, 230 mm flanged) 2) 2 (00 mm threaded, 380 mm flanged) 3) ) Barrier or Intrinsically Safe power supply required for Intrinsically Safe protection 2) Available with Probe version options B... D,, only [ 500 mm (9.69 inch)] 3) Available with Probe version options C, D, and only [ 750 mm (29.53 inch)] E B C D H J /5 Siemens I 0 Update /207

14 Pointek CLS Standard and Digital Order code urther designs Please add "-Z" to and specify Order code(s). Total insertion length: enter the total insertion length Y0 in plain text description Stainless steel tag [70 x 3 mm (2.75 x 0.5 inch)]: Y5 Measuring-point number/identification (max. 27 characters) specify in plain text Manufacturer's test certificate: M to DIN 55350, C Part 8 and to ISO 9000 Material Inspection Certificate Type 3. per C2 EN 020 Operating Instructions All literature is available to download for free, in a range of languages, at processinstrumentation/documentation Accessories See page /55 Accessories One metallic cable gland M20 x.5, C ( ) with integrated shield connection (available for PROIBUS PA) eneral Purpose /2" NPT eneral Purpose Cable Entry IP68/IP69K NEMA6, C ( ), cable size mm ( inch) M20 x.5 eneral Purpose Cable Entry IP68/IP69K NEMA6, C ( ), cable size mm ( inch) Hazardous Locations /2" NPT EMC rated Cable land: Dust Ignition Proof, lameproof Exd, and Increased Safety ATEX II 2 D ExtD A2 (Zone, Zone 2, Zone 2, Zone 22, and in as roups IIA,IIB and IIC) C IP66, IP67, IP68, NEMAX, cable sizes mm ( inch) M20 EMC rated Cable land: Dust Ignition Proof, lameproof Exd, and Increased Safety ATEX II 2 D ExtD A2 (Zone, Zone 2, Zone 2, Zone 22, and in as roups IIA,IIB and IIC) C IP66, IP67, IP68, NEMAX, cable sizes mm ( inch) Blind threaded flanges are available. Customers interested in a custom designed device should consult a local sales person. or more information, please visit 7ML930-AQ 7ML830-JA 7ML830-JC 7ML830-JB 7ML830-JD Pointek Specials See page /62 Siemens I 0 Update /207 /55

15 Pointek CLS Standard and Digital Characteristic curves Pressure/temperature curve CLS300 extended rod and cable probes Threaded process connections (7ML5650, 7ML565, 7ML5660 and 7ML566) Permitted operating pressures P 0 bar (580 psi) 30 bar (35 psi) Atmospheric - bar (-.5 psi) -50 ºC (-238 º) -00 ºC (-8 º) 20 bar (290 psi) 0 bar (5 psi) -0 º º (-0 ºC) (-0 ºC) -50 ºC (-58 º) -29 ºC (-20 º) 00 º (38 ºC) 200 º (93 ºC) 0 ºC RT 50 ºC 00 ºC (32 º) (22 º) (22 º) 300 º (9 ºC) 50 ºC (302 º) 00 º (20 ºC) 200 ºC (392 º) 500 º (260 ºC) 250 ºC (82 º) 600 º (35 ºC) 300 ºC (572 º) 700 º (37 ºC) 350 ºC (662 º) 00 ºC (752 º) Permitted operating temperature T Example: Permitted operating pressure = 30 bar (35 psi) at 75 C Pointek CLS300 process pressure/temperature derating curves (7ML5650, 7ML565, 7ML5660 and 7ML566) Pressure/temperature curve CLS300 high temperature rod probes Threaded process connections (7ML5652 and 7ML5662) Permitted operating pressures P 0 bar (580 psi) 30 bar (35 psi) 20 bar (290 psi) Atmospheric - bar (-.5 psi) -50 ºC (-238 º) -00 ºC (-8 º) 0 bar (5 psi) -0 º º (-0 ºC) (-0 ºC) -50 ºC (-58 º) -29 ºC (-20 º) 00 º (38 ºC) 200 º (93 ºC) 0 ºC RT 50 ºC 00 ºC (32 º) (22 º) (22 º) 300 º (9 ºC) 50 ºC (302 º) 00 º (20 ºC) 200 ºC (392 º) 500 º (260 ºC) 250 ºC (82 º) 600 º (35 ºC) 300 ºC (572 º) 700 º (37 ºC) 350 ºC (662 º) 00 ºC (752 º) Permitted operating temperature T Pointek CLS300 process pressure/temperature derating curves (7ML5652 and 7ML5662) /56 Siemens I 0 Update /207

16 Pointek CLS Standard and Digital Pressure/temperature curve CLS300 extended rod and cable probes ASME flanged process connections (7ML5650, 7ML565, 7ML5660 and 7ML566) Permitted operating pressures P 50 bar (725 psi) 0 bar (580 psi) 30 bar (35 psi) ASME 300 lb ) 20 bar (290 psi) Atmospheric - bar (-.5 psi) -50 ºC (-238 º) -00 ºC (-8 º) 0 bar (5 psi) -0 º º (-0 ºC) (-0 ºC) -50 ºC (-58 º) -29 ºC (-20 º) 00 º (38 ºC) 200 º (93 ºC) 0 ºC RT 50 ºC 00 ºC (32 º) (22 º) (22 º) 300 º (9 ºC) 50 ºC (302 º) 00 º (20 ºC) 200 ºC (392 º) 500 º (260 ºC) 250 ºC (82 º) 600 º (35 ºC) 300 ºC (572 º) 700 º (37 ºC) 350 ºC (662 º) ASME 50 lb ) 00 ºC (752 º) Permitted operating temperature T ) The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS300 process pressure/temperature derating curves (7ML5650, 7ML565, 7ML5660, and 7ML566) Permitted operating pressures P 90 bar (.305 psi) Pressure/temperature curve CLS300 high temperature rod probes ASME flanged process connections (7ML5652 and 7ML5662) 80 bar (.60 psi) 70 bar (.05 psi) 60 bar (870 psi) ASME 600 lb ) 50 bar (725 psi) 0 bar (580 psi) 30 bar (35 psi) ASME 300 lb ) 20 bar (290 psi) Atmospheric - bar (-.5 psi) -50 ºC (-238 º) -00 ºC (-8 º) 0 bar (5 psi) -0 º º (-0 ºC) (-0 ºC) -50 ºC (-58 º) -29 ºC (-20 º) 00 º (38 ºC) 200 º (93 ºC) 0 ºC RT 50 ºC 00 ºC (32 º) (22 º) (22 º) 300 º (9 ºC) 50 ºC (302 º) 00 º (20 ºC) 200 ºC (392 º) 500 º (260 ºC) 250 ºC (82 º) 600 º (35 ºC) 300 ºC (572 º) 700 º (37 ºC) 350 ºC (662 º) ASME 50 lb ) 00 ºC (752 º) Permitted operating temperature T ) The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS300 process pressure/temperature derating curves (7ML5652 and 7ML5662) Siemens I 0 Update /207 /57

17 Pointek CLS Standard and Digital Pressure/temperature curve CLS300 extended rod and cable probes EN flanged process connections (7ML5650, 7ML565, 7ML5660 and 7ML566) Permitted operating pressures P 50 bar (725 psi) 0 bar (580 psi) Atmospheric - bar (-.5 psi) -50 ºC (-238 º) -00 ºC (-8 º) 30 bar (35 psi) 20 bar (290 psi) 0 bar (5 psi) -0 º º (-0 ºC) (-0 ºC) -50 ºC (-58 º) -29 ºC (-20 º) 00 º (38 ºC) 200 º (93 ºC) 0 ºC RT 50 ºC 00 ºC (32 º) (22 º) (22 º) 300 º (9 ºC) 50 ºC (302 º) 00 º (20 ºC) 200 ºC (392 º) 500 º (260 ºC) 250 ºC (82 º) 600 º (35 ºC) 300 ºC (572 º) 700 º (37 ºC) 350 ºC (662 º) 00 ºC (752 º) PN 0 ) PN 6 ) Permitted operating temperature T ) The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS300 process pressure/temperature derating curves (7ML5650, 7ML565, 7ML5660 and 7ML566) Pressure/Temperature Curve CLS300 High Temperature Rod Probes EN langed Process Connections (7ML5652 and 7ML5662) Permitted Operating Pressures P 50 bar (725 psi) 0 bar (580 psi) 30 bar (35 psi) 20 bar (290 psi) PN 0 ) Atmospheric - bar (-.5 psi) -50 ºC (-238 º) -00 ºC (-8 º) 0 bar (5 psi) -0 º º (-0 ºC) (-0 ºC) -50 ºC (-58 º) -29 ºC (-20 º) 00 º (38 ºC) 200 º (93 ºC) 0 ºC RT 50 ºC 00 ºC (32 º) (22 º) (22 º) 300 º (9 ºC) 50 ºC (302 º) 00 º (20 ºC) 200 ºC (392 º) 500 º (260 ºC) 250 ºC (82 º) 600 º (35 ºC) 300 ºC (572 º) 700 º (37 ºC) 350 ºC (662 º) PN 6 ) 00 ºC (752 º) Permitted Operating Temperature T ) The curve denotes the minimum allowable flange class for the shaded area below. Pointek CLS300 process pressure/temperature derating curves (7ML5652 and 7ML5662) /58 Siemens I 0 Update /207

18 Pointek CLS Standard and Digital Dimensional drawings Rod version Threaded (7ML5650 and 7ML5660) Lid clip Electronics/ enclosure Lid 20 (0.79) High temperature rod version Threaded (7ML5652 and 7ML5662) 2 cable entries ½" NPT or M20 x.5 Y02 ) Thermal isolator M20: 35 (5.32) ½" NPT: 50 (5.9) Probe Measuring length Y0 (insertion length) min. = 250 (9.8)/max. = 000 (39.37) Ceramic isolator(s) Probe Ø9 (0.75) Ø9 (0.75) Y02 ) Measuring length Y0 (insertion length) min. = 250 (9.8)/max. = 000 (39.37) 59 (6.26) 52 (5.98) Lid with window P, DIP lid, without window XP, lid without window 6 (5.75) 23 (9.2) Thermal isolator Cable version, non-insulated Threaded (7ML565 and 7ML566) Cable version, insulated Threaded (7ML565 and 7ML566) Y02 ) Y02 ) 20 (9.5) 27 (9.72) Stainless steel cable Ø6 (0.2) Stainless steel weight 250 (9.8) Measuring length Y0 (insertion length) min. = 500 (20)/max. = (98) PA insulated cable Ø0 (0.35) Stainless steel weight 250 (9.8) Measuring length Y0 (insertion length) min. = 500 (20)/max. = (98) Note: Ø32 (.26) Ø32 (.26) ) Extended Active Shield (Y02): standard length 25 (.92). Optional active shield lengths: 250 (9.8) or 00 (5.75). Pointek CLS300 threaded process connections, dimensions in mm (inch) Siemens I 0 Update /207 /59

19 Pointek CLS Standard and Digital Rod version Welded flange (7ML5650 and 7ML5660) Lid clip Lid High temperature rod version Welded flange (7ML5652 and 7ML5662) 2 cable entries ½" NPT or M20 x.5 Electronics/ enclosure M20: 35 (5.32) ½" NPT: 50 (5.9) Probe Y02 ) Measuring length Y0 (insertion length) min. = 250 (9.8)/max. = 000 (39.37) Thermal isolator Ceramic isolator(s) Probe Y02 ) Measuring length Y0 (insertion length) min. = 250 (9.8)/max. = 000 (39.37) 8 (7.3) 7 (6.85) Lid with window P, DIP lid, without window XP, lid without window 68 (6.6) 257 (0.2) Thermal isolator 263 (0.35) 270 (0.63) Ø 9 (0.75) Ø 9 (0.75) Cable version, non-insulated Welded flange (7ML565 and 7ML566) Cable version, insulated Welded flange (7ML565 and 7ML566) lange acing (raised face) lange Class acing thickness ASME 50/300 2 (0.08) ASME 600/900 7 (0.28) PN6/0 2 (0.08) Stainless steel cable Ø 6 (0.2) Stainless steel weight 250 (9.8) Y02 ) Measuring length Y0 (insertion length) min. = 500 (20)/max. = (98) PA insulated cable Ø 0 (0.35) Stainless steel weight 250 (9.8) Y02 ) Measuring length Y0 (insertion length) min. = 500 (20)/max. = (98) Ø 32 (.26) Ø 32 (.26) Note: ) Extended Active Shield (Y02): standard length 05 (.3). Optional active shield lengths: 230 (9.06) or 380 (.96). Insertion length does not include any raised face/gasket face dimension (see lange acing Table above) Pointek CLS300 flanged process connections, dimensions in mm (inch) /60 Siemens I 0 Update /207

20 Pointek CLS Standard and Digital Schematics Wiring: Pointek CLS300 standard White Black Red P - + Delay Switch bank S O L2 Output status (+) L Sensor status 3 2 Sensor (f) K Trip point ND L3 Power on 2 3 Power supply 2 to 250 V AC/DC NC NO NO K2 K3 Solid state switch: 30 V DC/30 V AC (peak), 82 ma max. Relay contact: 8 A at 250 V AC, VA 5 A at 30 V DC, 50 W Notes: - Identification label is on underside of lid. Switch and potentiometer settings are for illustration purposes only (refer to operation/setup in manual). - All field wiring must have insulation suitable for at least 250 V. - Relay contact terminals are for use with equipment having no accessible live parts and wiring having insulation suitable for at least 250 V. - Maximum working voltage between adjacent relay contacts shall be 250 V. - Refer to the Instruction manual or contact Siemens representative for detailed wiring information. P2 K Wiring: Pointek CLS300 digital Test input White White Reed contact* Red (+) Alarm output solid-state switch Sensor 2 V DC/PROIBUS PA Black (-) Orange (f) Power connection: 2 V DC or PROIBUS PA bus (not polarity sensitive). Notes: Refer to the instruction manual or contact a Siemens representative for detailed wiring information. *Magnet activated sensor test A magnet can be used to test the sensor without opening the lid of the Pointek CLS300 digital version. Bring the magnet close to the test area indicated on the enclosure. The sensor test starts and finishes automatically after 0 seconds. Pointek CLS300 connections Siemens I 0 Update /207 /6

21 Pointek CLS Specials Selection and ordering data Pointek Specials ) Pointek Specials ) CLS00 Polycarbonate Lid and asket, KM Kit, sensor for cable units, PPS, digital, KM A5E Kit, sensor for cable units, PPS, standard, KM A5E Kit, sensor for cable units, PPS, digital, KM A5E Kit, Lid and gasket, CLS00 enclosure version CLS00 Miscellaneous Parts Custom length of cable is available only for 7ML550-xxxx and 7ML550-xxx5x 2) CLS200 asket (IP65), Synprene A5E06367 Kit, sensor for cable units, PVD, standard, KM Kit, sensor for cable units, PVD, digital, KM Kit, sensor for cable units, PVD, standard, KM Kit, sensor for cable units, PVD, digital, KM A5E06368 A5E A5E A5E06368 CLS200 Mounting Bracket, 36L stainless steel Spare gasket, enclosure version (IP65 versions only) A5E CLS200 asket (IP68), Silicone Spare mounting bracket A5E CLS200 PROIBUS Connector (IP65) Spare gasket, enclosure version (IP68 versions) A5E CLS200 Blind Lid Spare, PROIBUS connector (IP65 versions only) A5E CLS200 Miscellaneous Parts CLS200 with KM O-rings (any version) 2) CLS200 Electronics Test magnet, digital version 7ML830-JE Spare aluminum blind lid (for standard versions only) CLS200 Lid with window A5E06367 Amplifier/power supply kit, standard version Amplifier/power supply, digital version LCD display, digital version A5E ML830-J 7ML830-JK CLS300 Cable Extensions, 36L stainless steel Spare aluminum lid with window CLS200 Sensor Kit for cable units A5E Kit, stainless steel cable extension, m, A5E Kit, stainless steel cable extension, 3 m, A5E Kit, stainless steel cable extension, 5 m, A5E Kit, sensor for cable units, PPS, Standard, KM A5E Kit, stainless steel cable extension, 0 m, A5E06369 Kit, stainless steel cable extension, 5 m, A5E Kit, stainless steel cable extension, 20 m, A5E /62 Siemens I 0 Update /207

Point level measurement Capacitance switches

Point level measurement Capacitance switches Pointek CLS300 Standard Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable choices and configurable output.

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview. Level Measurement Pointek CLS300 Standard Siemens AG 20 Overview Configuration Installation Pointek CLS300 (standard version) is an inverse frequency shift capacitance level switch with optional rod/cable

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Overview Configuration Installation is an inverse frequency shift capacitance level and material detection switch ideal for detecting interfaces, solids, liquids, toxic, and aggressive chemicals in critical

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 5/16 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 5/16 Siemens FI Overview. Level Measurement Pointek LS200 Standard Siemens A 20 Overview onfiguration Installation Pointek LS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable

More information

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview. Overview Configuration is an inverse frequency shift capacitance continuous It is ideal for standard industrial applications in chemical, hydrocarbon processing, food and beverage and mining, aggregate

More information

Level Measurement Continuous level measurement - Capacitance transmitters

Level Measurement Continuous level measurement - Capacitance transmitters Overview Probe Applications Rod version Rod version with stilling well Cable version PFA coated cable version Extended cable with rod version Conductive liquids, slurries or solids Conductive liquids or

More information

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview. SITRANS LC00 Overview Configuration Installation Build up of material or condensation in active shield area does not affect switch operation. SITRANS LC00 is an inverse frequency shift capacitance level

More information

Continuous level measurement Capacitance transmitters

Continuous level measurement Capacitance transmitters Siemens AG 2011 Level Measurement SITRANS LC00 Overview Configuration Installation Build up of material or condensation in active shield area does not affect switch operation. SITRANS LC00 is an inverse

More information

Level Measurement Continuous level measurement Ultrasonic transmitters

Level Measurement Continuous level measurement Ultrasonic transmitters Siemens AG 2018 Overview Configuration ultrasonic level transmitter, ideal for level, volume, and volume flow measurements. It works with liquids, slurries, and bulk materials up to 12 m (0 ft). Benefits

More information

Level Measurement Continuous level measurement - Radar transmitters

Level Measurement Continuous level measurement - Radar transmitters Overview Configuration Installation Note: Beam angle is the width of the cone where the energy density is half of the peak energy density Emission The peak energy density cone is directly in front of and

More information

Level Measurement Point level measurement - Vibrating switches

Level Measurement Point level measurement - Vibrating switches Overview Configuration Horizontal mounting (recommended mounting position, particularly for adhesive applications) Vertical mounting is a compact vibrating level switch for material detection in liquid

More information

Process Protection Motion sensors

Process Protection Motion sensors Overview MFA 4p motion failure alarm controller is a highly sensitive single setpoint motion sensor system, used with Milltronics MSP probes. Application The MFA 4p detects changes in the motion and speed

More information

Process Protection Motion sensors

Process Protection Motion sensors Overview MFA 4p motion failure alarm controller is a highly sensitive single setpoint motion sensor system, used with Milltronics MSP probes. Design Benefits Up to 100 mm (4 inch) gap between target and

More information

Process Protection Motion sensors

Process Protection Motion sensors Overview MFA 4p motion failure alarm controller is a highly sensitive single setpoint motion sensor system, used with Milltronics MSP probes. Application The MFA 4p detects changes in the motion and speed

More information

Level limit switch Series RF 3000 Selection list

Level limit switch Series RF 3000 Selection list Table of content Page Overview P2 Applications P4 ------------------------------------------------------------------------------------------------------------- RF 3100 Standard version P6 -------------------------------------------------------------------------------------------------------------

More information

Level Measurement Point level measurement - Vibrating switches

Level Measurement Point level measurement - Vibrating switches Siemens G 2018 SITRNS LVS200 Overview SITRNS LVS200 is a vibrating point level switch for high, low, or demand level detection of bulk solids. enefits High resistance to mechanical forces Strong vibration

More information

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage Data Sheet Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use Compact

More information

Level instruments. Point level measurement - Vibrating switches SITRANS LVL100. 5/78 Siemens FI Horizontal mounting.

Level instruments. Point level measurement - Vibrating switches SITRANS LVL100. 5/78 Siemens FI Horizontal mounting. evel instruments Siemens AG 2009 Overview Configuration Horizontal mounting (recommended mounting position, particularly for adhesive applications) Vertical mounting with lower density is a compact vibrating

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview Benefits It is compact and light, fitting neatly into dense piping arrangements Effective separation of measurement from plant vibration Reliable measurements due to high signal to noise ratio

More information

SITRANS L Level instruments

SITRANS L Level instruments Overview Configuration is a compact vibrating level switch for use in liquid applications such as overflow, high, low and demand applications, as well as pump protection. It is ideal for use in confined

More information

Belt Scales Speed sensors

Belt Scales Speed sensors Overview is a low- to high-resolution shaft-driven speed sensor. Benefits Compact and economical Easy, low-cost installation Accurate belt speed detection Optional resolutions for measurement over a range

More information

Motion sensors. Milltronics MFA 4p 6/17. Overview

Motion sensors. Milltronics MFA 4p 6/17. Overview Siemens AG 2013 Overview MFA 4p motion failure alarm controller is a highly sensitive single setpoint motion sensor system, used with Milltronics MSP probes. Application The MFA 4p detects changes in the

More information

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4

Level limit switch Series CN 4000 Selection list. Specifications 2. Applications 4 Table of contents Page Specifications 2 Applications 4 ------------------------------------------------------------------------------------------------------------ CN 4020 5 Short extension length ------------------------------------------------------------------------------------------------------------

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

Belt Scales Speed sensors

Belt Scales Speed sensors Overview is a low- to high-resolution shaft-driven speed sensor. Benefits Compact and economical Easy, low-cost installation Accurate belt speed detection Optional resolutions for measurement over a range

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application Overview SITRANS F flowmeters Application Liquid applications Gas applications Pipelines Custody transfer, allocation, Upstream Production wells, line balance, gathering, separation interface/densitometer

More information

Level Measurement Point level measurement - Rotation paddle switches

Level Measurement Point level measurement - Rotation paddle switches Siemens 017 SITRNS LPS00 Overview SITRNS LPS00 is a rotary paddle switch for point level and material detection in bulk solids. enefits Proven paddle switch technology for bulk solids High integrity mechanical

More information

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01 CAPACITIVE LEVEL SWITCHES Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01 HYCONTROL CAPACITIVE LEVEL SWITCH RANGE Hycontrol ME capacitive level switches provide simple, accurate and reliable level

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Application The pressure transmitter is designed for the special requirements of the food, pharmaceutical and biotechnology industries. The use of high-grade materials guarantees compliance with

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The electromagnetic sensor MAG 1100 F is designed to meet applications in the food and beverage industry. Benefits sizes: 10 to 100 (/8 to 4 ) AISI 16 stainless steel enclosure : Hygienic connection,

More information

Temperature Measurement Resistance thermometers

Temperature Measurement Resistance thermometers Temperature transmitters for mounting in the connection head The following temperature transmitters are available for mounting in the connection head: SITRANS TH100 Programmable two-wire temperature transmitter

More information

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage Data Sheet Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage Reliable through well-proven concept - More than 1,000,000 units in use

More information

Overview. Specifications. Applications

Overview. Specifications. Applications Vibranivo Level limit switch 1 Series VN 00 / 000 / 000 / 000 Table of content Page Overview P Specifications P Applications P ------------------------------------------------------------------------------------------------------------

More information

Flow Measurement SITRANS F C

Flow Measurement SITRANS F C Overview The complete flowmeter system SITRANS FC40 can be ordered for standard, hygienic or NAMUR service. All versions can be ordered for CT service, according to OIML R 117 (Liquids other than water)

More information

RS85 Vibrating fork level switch

RS85 Vibrating fork level switch Data sheet DS/-EN Rev. P Multi-option liquid level switch K-TEK Level products Measurement made easy Features Direct replacement for ultrasonic Gap switches, RF capacitance switches, float switches and

More information

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating

V200 Positioner. V200 P Pneumatic Positioner. V200 E Electropneumatic Positioner. Housing Material: Cast aluminium with polyester coating V200 Positioner Housing Material: Cast aluminium with polyester coating Indicator Options: Flat pointed indicator or raised indicator (red/green or yellow/black) One housing for pneumatic or electropneumatic

More information

Continuous level measuring system NB 4000 Selection list

Continuous level measuring system NB 4000 Selection list Table of contents Page Overview P2 Specification / application P3 P4 Options / Accessories P6 Dimensions / materials P7 Spare parts P9 Electrical installation P11 Subject to change. All dimensions in mm

More information

TORRIX Magnetostrictive level sensor

TORRIX Magnetostrictive level sensor TORRIX Magnetostrictive level sensor Precision Versatility Security Sensors & Systems Worldwide: www.fafnir.com FAFNIR Quality and Satisfaction Company: Based in Hamburg, Germany, FAFNIR GmbH has over

More information

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M Overview The electromagnetic sensor MAG 1100 F is designed to meet applications in the food and beverage industry. Benefits sizes: 10 to 100 (/8 to 4 ) AISI 16 stainless steel enclosure : Hygienic connection,

More information

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview

Flow Measurement SITRANS F M. Flow sensor MAG /85. Overview Siemens AG 2010 low Measurement Overview Design Compact or remote mounting possible Easy plug & play field changeability of transmitter Ex ATEX and M/CSA versions High temperature sensor for applications

More information

Sensor boxes SRBE Key features and product range overview

Sensor boxes SRBE Key features and product range overview Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic

More information

Mobrey MSM400 Ultrasonic sludge density measurement system

Mobrey MSM400 Ultrasonic sludge density measurement system Technical specification sheet IP257 October 2008 Mobrey MSM400 Ultrasonic sludge density measurement system Level Features Measuring range up to 50% solids Simple keypad operation HMI menu based programming

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 8032 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable outputs (transistor or relay) Automatic-calibration:

More information

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES Technical Information TI 240F/00/en Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES Compact capacitive level probes (with European certificates). Fully and partially insulated rod and

More information

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit > A Higher Level of Performance Data Sheet Centurion Guided Radar CGR Series For more information, please visit > www.hawkmeasure.com / Dimensions Centurion Guided Wave Radar Radar Principle of Operation

More information

OPTISWITCH 4000/5000. Vibration level switches for liquids

OPTISWITCH 4000/5000. Vibration level switches for liquids OPTISWITCH 4000/5000 Technical Datasheet Vibration level switches for liquids Operates up to 250 C / 480 F and 64 bar / 925 psi Pump dry-run detection High reliability due to permanent fault monitoring

More information

OM004, OM006 & OM008 Oval Gear Meter

OM004, OM006 & OM008 Oval Gear Meter OM SERIES OM004, OM006 & OM008 Oval Gear Meter OM004 (1/8"), OM006 (1/4") and OM008 (3/8") Oval Gear Meters ACCURACY: ±1.0% OF READING Select Your Body Material: Aluminum or Stainless Steel The OM Small

More information

BM 26 BASIC/ADVANCED Technical Datasheet

BM 26 BASIC/ADVANCED Technical Datasheet BM 26 BASIC/ADVANCED Technical Datasheet Magnetic bypass Level Indicator (MLI) for generalpurpose applications Best price / performance ratio Full stainless steel construction IP68 local indicator with

More information

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI Siemens AG Flow sensor MASS DI 3 to DI 0 Overview MASS DI 3 to DI 0 is suitable for accurate mass flow measurement of a variety of liquids and gases. The sensor offers superior performance in terms of

More information

Electromagnetic Flow Monitor magphant

Electromagnetic Flow Monitor magphant Technical Information TI 036D/24/ae Electromagnetic Flow Monitor magphant Flow monitoring in 1 to 80 pipes with conductive liquids Monitoring and measurement Flow monitoring with selectable limit values

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

Level Limit Switch liquiphant FTL 365 / FTL 366

Level Limit Switch liquiphant FTL 365 / FTL 366 Technical Information TI 86F/00/en Level Limit Switch liquiphant FTL 65 / FTL 66 Level limit switch Liquiphant II with vibrating probe. For all types of liquid. With explosionproof housing for use in hazardous

More information

Level Limit Switch soliphant II FTM 30 (D/S), FTM 31 (D/S), FTM 32 (D/S)

Level Limit Switch soliphant II FTM 30 (D/S), FTM 31 (D/S), FTM 32 (D/S) Technical Information TI 9F/00/en Level Limit Switch soliphant II FTM 0 (D/S), FTM (D/S), FTM (D/S) Universal vibration limit switch for fine-grained bulk solids Suitable for dust explosion hazardous areas

More information

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF) Level measurement Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF) TC Fluid Control WIKA data sheet LM LM 3001 30.01 for further approvals see page 3 Applications

More information

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring

More information

Digital ph transmitter

Digital ph transmitter Digital ph transmitter Compact, remote versions for DN 15 to 200 Fully programmable ph transmitter functions for all kinds of ph-measurement tasks Large range of process connections with various fittings

More information

Continuous level measuring system NB 3000 Selection list. Overview

Continuous level measuring system NB 3000 Selection list. Overview Table of contents Page Overview P2 ------------------------------------------------------------------------------------------------------------------- Specifications P3 -------------------------------------------------------------------------------------------------------------------

More information

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve Ex d Ex m IP5 Series 3 Way Direct Acting Balanced Poppet Solenoid Valve DB2S-M2C \ Ex d IIC with Integral Stainless \ Steel Junction Box. \ Valve. \ Manual Override, Option M2. J77072S-M2 \ Ex m II NASS

More information

VersaFlow Vortex 100 Vortex Flow Meter Specifications

VersaFlow Vortex 100 Vortex Flow Meter Specifications VersaFlow Vortex 100 Vortex Flow Meter Specifications 34-VF-03-05 May 2011 The All-In-One Solution The VERSAFLOW is the only vortex flowmeter with integrated and temperature compensation in 2- wire technology.

More information

Micro Motion F-Series Coriolis Flow and Density Meters

Micro Motion F-Series Coriolis Flow and Density Meters Product Data Sheet PS-00603, Rev. F December 2007 Micro Motion F-Series Coriolis Flow and Density Meters Micro Motion F-Series Coriolis meters offer highly accurate mass flow, volume flow, and density

More information

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS

VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS FEATURES AND BENEFITS STANDARD VS. ADVANCED UNITS VRF II Series SURPASSING SENSITIVITY FOR THE TOUGHEST APPLICATIONS The VRF II Series uses radio frequency to detect the presence or absence of material in a vessel. It compensates for the load of the probe

More information

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit > A Higher Level of Performance Data Sheet Centurion Guided Radar CGR Series For more information, please visit > www.hawkmeasure.com / Dimensions Centurion Guided Wave Radar Radar Principle of Operation

More information

SITRANS F C. Flow sensor MC2 4/193. Overview

SITRANS F C. Flow sensor MC2 4/193. Overview Siemens G 2011 low Measurement SITNS C Overview The main applications of the Coriolis flowmeter can be found in all industries, such as: Chemical and pharma Detergents, bulk chemicals, pharmaceuticals,

More information

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter Product Data Sheet February 2015 IP119, Rev CA Displacer Level Transmitter Level, contents or interface measurement transmitter Direct or external chamber mounting 4 20 ma HART output ATEX Intrinsically

More information

STEEMCO Flowmeter for Steam

STEEMCO Flowmeter for Steam STEEMCO Flowmeter for Steam Typical Applications The STEEMCO flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical

More information

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals ABB MEASUREMENT & ANALYTICS DATA SHEET TEIP11 I/P signal converter for standard signals 2 TEIP11 I/P SIGNAL CONVERTER FOR STANDARD SIGNALS DS/TEIP11-EN REV. D Flow in air pressure Proven and reliable concept

More information

SITRANS F M. Flow sensor MAG 1100 F 3/59

SITRANS F M. Flow sensor MAG 1100 F 3/59 Overview Integration The complete flowmeter consists of a sensor and an associated transmitter MAG 5000, 6000 and 6000 I. The flexible communication concept USM II simplifies integration and update to

More information

Paddle-wheel flow controller for On/Off control

Paddle-wheel flow controller for On/Off control Paddle-wheel flow controller for On/Off control Type 803 can be combined with... Indication, monitoring, transmitting and On/Off control in one device Programmable s (transistor or relay) Automatic-calibration:

More information

Belt Scales Milltronics belt scales

Belt Scales Milltronics belt scales Overview pplication provides continuous, in-line weighing at minimal cost. The stainless steel load cells ensure long-term, consistent, reliable measurement. The modular construction and easy assembly

More information

Inductive conductivity meter

Inductive conductivity meter Inductive conductivity meter Type 8228 can be combined with... Configurable outputs: up to 2 transistor and up to 2 analog 4... 20 ma outputs Removable backlighted display Simulation of process values

More information

BM 26 BASIC/ADVANCED Technical Datasheet

BM 26 BASIC/ADVANCED Technical Datasheet BM 26 BASIC/ADVANCED Technical Datasheet Magnetic bypass Level Indicator (MLI) for generalpurpose applications Best price / performance ratio Full stainless steel construction IP 68 local indicator with

More information

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam Metal tube flowmeters Variable area flowmeter for liquids, gases and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h,

More information

Weighfeeders SITRANS WW200

Weighfeeders SITRANS WW200 Introduction Overview is a low- to medium-capacity weighfeeder used for minor ingredient additives. Benefits High accuracy Ideal for low- to medium-capacity loads Fast installation, easy to clean and maintain

More information

Level Measurement Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement Radar transmitters Overview The SITRANS LR250 hygienic encapsulated antenna is a 2 wire 25 GHz pulse radar level transmitter with sanitary and hygienic approvals for continuous monitoring of liquids, slurries and pastes

More information

Inductive conductivity meter

Inductive conductivity meter Inductive conductivity meter CIP version Type 8228 can be combined with... Standard version Perfect for concentrated liquids and wide conductivity range Pre-parameterized versions available for direct

More information

Metal tube variable area flowmeter for gases, liquids and steam

Metal tube variable area flowmeter for gases, liquids and steam Metal tube variable area flowmeter for gases, liquids and steam Metallic or plastic tube with a robust construction Indication by means of magnetic coupling Scales calibrated in l/h, m 3 /h, kg/h, t/h,

More information

STEEMCO-MAS Flowmeter for Steam

STEEMCO-MAS Flowmeter for Steam STEEMCO-MAS Flowmeter for Steam Typical Applications The STEEMCO-MAS flow meters measure the mass flow of superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical

More information

Flap-Type Flow Meter Prall

Flap-Type Flow Meter Prall Suitable for H 2 O, acids, alkaline solutions and gases Spring-loaded flap Horizontal or vertical direction of flow Largely independent of viscosity Limit contacts, optional Analog output 4 20 ma, optional

More information

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids Suitable for all kind of liquids Viscosity up to 120000 mpa s Excellent performance with changing process conditions

More information

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram Data Sheet 403025 Page 1/10 JUMO dtrans p20 Process pressure transmitter Brief description The JUMO dtrans p20 pressure transmitter with HART interface combines maximum precision with easy operation. It

More information

Continuous level measuring system. LevelMax. Selection Guide. Overview 2

Continuous level measuring system. LevelMax. Selection Guide. Overview 2 Table of contents Page Overview 2 ------------------------------------------------------------------- Specification / application 3 ------------------------------------------------------------------- 4

More information

Soliphant II FTM30(D/S)/31(D/S)/32(D/S)

Soliphant II FTM30(D/S)/31(D/S)/32(D/S) Technical Information Soliphant II FTM0(D/S)/(D/S)/2(D/S) Level Limit Switch Universal vibration limit switch for fine-grained bulk solids Suitable for dust explosion hazardous areas Application Soliphant

More information

Continuous level measuring system NB 3000 Selection list

Continuous level measuring system NB 3000 Selection list Table of contents Page Overview 2 ------------------------------------------------------------------------------------------------------------------- Specifications 3 -------------------------------------------------------------------------------------------------------------------

More information

Mobrey Squitch 2 Ultrasonic Liquid Level Switch

Mobrey Squitch 2 Ultrasonic Liquid Level Switch Product Data Sheet Mobrey Squitch 2 Mobrey Squitch 2 Ultrasonic Liquid Level Switch A compact, self-contained, ultrasonic gap sensor, designed for switching in clean liquids Mounting options including

More information

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands

Conductivity meter. PLC Solenoid valve. Type Type On/Off Diaphragm valve. Valve islands Conductivity meter Configurable outputs: two transistor and single or dual analog 4... 20 ma Removable backlighted display Universal process connection Type can be combined with... Three cell constants

More information

DIAMOND POINT VIBRATING PROBES

DIAMOND POINT VIBRATING PROBES DIAMOND POINT VIBRATING PROBES DP130 DP120 DP140 DP150 Instruction Manual Third revision, April 2016 Hycontrol Ltd., Larchwood House, Orchard Street, Redditch, Worcestershire, B98 7DP, U.K. Tel: + 44 (0)1527

More information

Proximity Transmitters, and Seismic Vibration Transmitters

Proximity Transmitters, and Seismic Vibration Transmitters TM016 Velocity/ Acceleration Vibration Transmitter Introduction The TM016 is a solid state loop powered transmitter which provides a 4-20mA output proportional to the machine case vibration level. The

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-1 Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview

SITRANS F flowmeters SITRANS F C SITRANS F C MC2 4/169. Overview Siemens G 2009 SITRNS flowmeters SITRNS C SITRNS C MC2 Overview SITRNS C MC2 is available as a standard version (DN 50 to DN 150 (2 to 6 )) and a hygienic, EHEDG-certified version (DN 20 to DN (¾ to 3

More information

Paddle-wheel flow controller with optical principle for On/Off control

Paddle-wheel flow controller with optical principle for On/Off control Paddle-wheel flow controller with optical principle for On/Off control Type 8039 can be combined with... Indication, monitoring, transmitting and On/Off control in one device. Programmable s (transistor

More information

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65 2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65 Type 2000 can be combined with High flow rate Long life cycle NC and NO universal s with modular universal accessory

More information

Level Probes multicap DC 11/16/21/26 EN multicap DC 11/16/21/26 ES

Level Probes multicap DC 11/16/21/26 EN multicap DC 11/16/21/26 ES Technical Information TI 242F/00/en Level Probes multicap DC 11/16/21/26 EN multicap DC 11/16/21/26 ES Fully and partially insulated rod and rope probes for capacitive level measurement and limit detection

More information

Direct-acting 3/2 way plunger valve

Direct-acting 3/2 way plunger valve Direct-acting 3/2 way plunger valve Direct-acting, compact valve with diameter of up to DN 2.5 Vibration-proof, bolted coil system Banjo threaded connection for direct mounting on pneumatic valves Type

More information

POSITIONERS and Controls for Complete Valve Automation

POSITIONERS and Controls for Complete Valve Automation CONTROLS A Division of AT Controls Pneumatic & Electro-Pneumatic POSITIONERS and Controls for Complete Valve Automation 1 SS SERIES SS Features Easy and quick auto-calibration Detecting RA (reverse acting)

More information

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm Industrial Pressure Transmitter Pressure Ports With Flush Welded Stainless Steel Diaphragm accuracy according to IEC 60770: 0.5 % FSO Nominal pressure from 0... 60 bar up to 0... 400 bar Output signals

More information

Masoneilan Series

Masoneilan Series Masoneilan 12300 Series Digital Level Transmitter & Controller Specification Data CU3000 02/02 Digital Level Measurement and Control Instrumentation Table of Contents General Description...2 Principle

More information

NIVOSWITCH R-400/R-500

NIVOSWITCH R-400/R-500 NIVOSWITCH R400/R500 VIBRATION FORK LEVEL SWITCHES Dual purpose level switch with intelligent electronics applicable for: almost all liquids light, free flowing solids cellent noise immunity through high

More information