TECHNICAL MANUAL AND APPLICATION GUIDE. Engineering Your Power

Size: px
Start display at page:

Download "TECHNICAL MANUAL AND APPLICATION GUIDE. Engineering Your Power"

Transcription

1 r e v. 0 3 r e l e a s e d Engineering Your Power Medium-Voltage Switchgear MILE MP12, MP17 and MP24 Single Busbar Air-Insulated Metal-Clad Switchgear Circuit Breaker mounted on withdrawable Cassette / Truck All switching operations performed with front door closed TECHNICAL MANUAL AND APPLICATION GUIDE

2 TECHNICAL MANUAL AND APPLICATION GUIDE CONTENTS 2 ABBREVIATIONS 5 TECHNICAL MANUAL 6 1. GENERAL Presentation Applicable standards Degrees of protection Normal service conditions Type testing Routine factory tests Internal arc proof 8 2. DESIGN Compartments Busbar compartment Cable compartment Circuit breaker compartment Low voltage compartment Withdrawable parts Main busbars Branch connections Earthing busbar Bushing insulators and shutters Cables Automation and auxiliary wiring Pressure relief flaps and gas exhaust duct Doors Natural ventilation Maintenance BASIC STRUCTURE Typical panels Top Installation EQUIPMENT Cassette/Truck platform Truck/Cassette circuit breaker Abbreviation description Selection parameters ISM15-DOU-LD description ISM25-DOU-LD description ISM15-DOU-HD Description ISM25-DOU-HD Description ISM15-DOUT-HD Description VT-DOU Desctription IT-DOU Description Circuit breaker Presentation Overall design Magnetic actuator Vacuum interrupters Control modules Current transformers 40 2

3 Medium-Voltage Switchgear MILE MP12, MP17 and MP Voltage transformers Zero sequence current transformer Earthing switch Surge Arresters Cassette type to truck type transformation INTERLOCKS AND LOCKING DEVICES TECHNICAL SPECIFICATIONS OVERALL DIMENSIONS 47 APPLICATION GUIDE SELECTION Selection description INSTALLATION Packaging, handling, storage Packaging Storage Unpacking and installation of the equipment Foundation surface Unpacking panels Panels installation, fixing and positioning Positioning panels in switchboard Connecting panels Panels Main busbar Earthing busbar Control cables interconnection Fixing the cables OPERATION Withdrawable Parts Position Definitions Interlocking Conditions Interlock mechanisms Standard supply Optional supply Locking facilities Interlock between panels Circuit breaker panel (IF, OF, BC) Operations with draw-out unit Operations with earthing switch Metering panel (MES) Operations of draw out unit with voltage transformer Operations with busbar earthing switch Load-break switch feeder (LBSF) Operations with load break switch Operations with earthing switch Service trolley operation Moving DOU from the removed position to the isolated position Moving DOU from the isolated position to the removed position Set of tools Troubleshooting CM Malfunction detection Opening of the cable and circuit breaker compartment doors in emergency cases. Interlock overcoming. 71 LIST OF CHANGES 72 NOTES 73 3

4 TECHNICAL MANUAL AND APPLICATION GUIDE It is absolutely necessary to read this document carefully before starting the installation or operation of MILE switchgear and to adhere to the instructions and the relevant regulations contained in it. SAFETY FIRST Make sure that during installation, commissioning and operation, the respective legal regulations (such as IEC) and appropriate national safety regulations are adhered to. Make sure that the installation, commissioning and the operation are carried out by electrical specialists. Only install the switchgear in closed rooms designated for electrical equipment. Make sure that the specified data are not exceeded under the switchgear operation. Make sure that this manual is available to all persons concerned with installation, commissioning and operation. Note especially the important or danger information that is marked as follows in this manual: The user's personnel must act responsibly in all matters affecting safety at work and correct handling of the switchgear. WARNING! Always follow the instruction manual and respect the rules of good engineering practice! Hazardous voltage can cause electrical shocks and burns. Disconnect power, then earth and shortcircuit before proceeding with any work on this equipment. Low voltage devices (mainly control modules) of all types meet the requirements of the EMC Directive 2006/95, the Low Voltage Directive 2004/108 4

5 Medium-Voltage Switchgear MILE MP12, MP17 and MP24 ABBREVIATION TEL - Tavrida Electric (registered TM) TEE - Tavrida Electric Export Ltd. VCB - Vacuum circuit breaker MP - Medium-Voltage switchgear MILE type DOU - Draw-out unit IEC - International Electrotechnical Commission IP - International protection ISM - Indoor switching module CM - Control module LD - Low duty switching module HD - High duty switching module IAC - Internal arc classification RTU - Remote terminal unit IF - Incoming Feeder OF - Outgoing Feeder BC - Bus Coupler BR - Bus Riser BRES - Bus Riser with Earth Switch BRM - Bus Riser with Metering Transformer M - Metering panel MES - Metering panel with Earth Switch STP - Service Transformer Panel LBSF - Load-Break Switch with Fuses Useful Features (useful and helpful information) are highlighted with: Examples of calculations, hints: Note especially the warnings that are marked with: Technical stuff: Danger! : 5

6 TECHNICAL MANUAL AND APPLICATION GUIDE TECHNICAL MANUAL This manual provides general information and specifications, intended for the selection of the switchgear. 1. GENERAL 1.1 Presentation The MILE MP series switchgear is designed for primary distribution networks with the rated voltages of 12kV, 17.5kV and 24kV 50/60Hz intended for indoor installation. The MILE MP series switchgear is airinsulated LSC2B-PM class, with single busbar design. The switchgear concept meets today's owner requirements such as reliability, personnel and operational safety, economy and efficiency in an optimal way. The switchgear is modular and is built up by placing standardized units side by side in a coordinated way. The switchgear is easy to configure and selection of the apparatus and instruments does not imply dedicated solutions. The functional units of the switchgear are guaranteed arc proof AFLR 31,5kA 1s in accordance with the IEC standard, appendix AA, class A accessibility, criteria 1 to 5. All the start-up, maintenance and service operations can be carried out from the front. The switchgear and the earthing switches are operated from the front with the door closed. The MILE MP series switchgear can be with front access or with front and rear access. 1.2 Applicable standards The switchgear and its main apparatus comply with the following standards: IEC : High-voltage switchgear and controlgear Part 1: Common specifications IEC : High-voltage switchgear and controlgear Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kv and up to and including 52 kv IEC : High-voltage switchgear and controlgear Part 200: High-voltage alternating current disconnectors and earthing switches IEC : Insulation co-ordination Part 2: Application guide IEC : High-voltage switchgear and controlgear Part 100: High-voltage alternating current circuit-breakers IEC : High-voltage switches Part 1: Switches for rated voltages above 1 kv and less than 52 kv 1.3 Degrees of protection The degrees of protection of the switchgear conforms with IEC standard. The MILE MP series switchgear is normally supplied with the following standard degrees of protection: IP4X on the external housing IP3X with the doors open 1.4 Normal service conditions The rated characteristics of the switchgear are guaranteed under the following ambient conditions: In accordance with IEC standard. Parameter IP41 on request Parameter value Minimum ambient temperature - 40 C* Maximum ambient temperature +40 C (on request +55 C) Maximum altitude above sea level 3000 m ** Relative humidity 95% Ambient atmoshpere Presence of normal, non-corrosive and uncontaminated atmosphere. * with selected microprocessor electronics only. ** in accordance with IEC for altitudes above 1000 m, it is required to take into consideration the decrease of dielectrical strength applying factor from the table. The MILE MP series switchgear are suitable for operation in the climate of Wda type in accordance with IEC standard. Altitude above sea level, m , , , , , , ,80 Air dielectric strength factor 6

7 Medium-Voltage Switchgear MILE MP12, MP17 and MP Type testing The MILE switchgear has successfully passed all the tests specified by relevant IEC (International Standard) and GOST (Russian national standard) standards. As noted within the regulations of these standards, the tests were carried out on the switchgear units considered to be the most sensitive to stresses applied within the tests and therefore assigned to be valid on the whole range. Type tests: Short-time and peak withstand current test on primary circuits Short-time and peak withstand current test on earthing circuits including draw out unit. Temperature rise and main circuit impedance measurements. Dielectric test on main and auxiliary circuits. Making and breaking capacity of the apparatus. Earthing switch making capacity. Mechanical operations. Verification of the IP coding Internal arc test. 1.6 Routine factory tests Routine tests are performed by the assembly factory as specified in (the standard) IEC to ensure the superior quality of each product to be delivered to a customer site: 1. Visual inspection Conformity of primary and secondary equipment Conformity of measuring instruments Enclosure Coating Equipment marking Wiring marking Wire conformity Conformity of neutral and protection wiring 2. Electrical wiring inspection Wire tightening check Wiring check as per project 3. Mechanical tests Enclosure fittings check Busbars and equipment tightening check Earthing tightening check Circuit breaker Draw-out unit Earthing switch Mechanical interlocks 4. Insulation resistance check Before L1-L2-L3 (L1-L2-L3)-PE After L1-L2-L3 (L1-L2-L3)-PE 5. Power frequency voltage test (L1-L2-L3)-E (L1)-E-L2-L3 (L2)-E-L1-L3 (L3)-E-L1-L2 6. Electrical operability tests Control circuits check Electrical interlock check Measuring circuits check 7

8 TECHNICAL MANUAL AND APPLICATION GUIDE 1.7 Internal arc proof The personnel safety factor was a primary goal when MILE switchgear was designed. Thus, the MILE switchgear has been designed and tested to withstand an internal arc due to a short-circuit current of the same levels as the panel rated breaking currents. These tests ensure that the metal construction of the MILE switchgear is able to protect personnel operating near the switchgear subjected to an internal arc fault. The internal arc is treated to be the most unlikely event from all type of faults, however a small percentage of occurrence still exists due to many factors including improper connection of incoming cables and tightening contact connections, intrusion of the animals, deterioration of the insulation within time or severe atmospheric conditions and human factor. The proved characteristics of the MILE switchgear drastically reduce the incidence of these causes in generation of faults, but some of them cannot be fully eliminated. The event of internal arc produces a huge amount of energy which instantly transforms into phenomena such as rapid increase of the internal pressure and temperature, visual and sound effects, which consequently result in high mechanical stresses on the switchgear structure, structure and in melting and evaporation of the materials. Such significant stresses, unless properly controlled, may cause serious life threat to the service personnel due to harmful effects (shock-wave, flying parts, doors opening, emission of hot gases, open flame). The IEC Standard describes the testmethods and criteria to be used for testing. The MILE switchgear conforms to all criteria stated in the Annex A of the standard: The doors of the switchgear must remain closed and no opening of the cover panels must occur. No part of the switchgear, which may be hazardous for personnel, may be ejected. Arcing does not cause holes in the accessible sides up to a height of 2 m. Vertically and horizontally arranged fabric indicators placed outside the switchgear may not get burnt. All the switchgear earthing connections must remain effective. The MILE switchgear is IAC classified: AFLR 31.5kA, 1s. For the installation of the MILE switchgear the following factors are obligatory to be considered: Level of the fault current ( ka). Duration of the fault ( s). Hot gases evacuation routes. Dimensions of the switchboard room, with special attention to the height. TEE has developed various solutions providing effective control and protection over the arc initiation at earlier stages as well as passive type protection based on construction. 2 2 I t, ka s Total breaking time with arc protection 16 ms Copper fire (~1100 C) Cable fire (~600 C) Steel fire (~1550 C) ms 8

9 Medium-Voltage Switchgear MILE MP12, MP17 and MP24 The arc protection system can be based on different types of arc detection sensors: - microswitches on pressure relief flap; - pressure sensors; - optical sensors with combination of earth-fault detection; - phototyristor sensors. Tavrida circuit breakers are designed with the entire concept in mind optimizing vacuum interrupter, insulation, magnetic actuator and control modules. This has resulted in the fastest circuit breaker, the one cycle interrupter - a breakthrough for fast switching and arc flash protection technology. Once the circuit breaker receives the trip signal from an arc-flash relay, it is able to interrupt in less than sixteen milliseconds (ms) to provide increased arc flash hazard mitigation the fastest arc fault interruption in the industry helping to reduce work-related injuries, fatalities and lost productivity. 9

10 TECHNICAL MANUAL AND APPLICATION GUIDE 2. DESIGN 2.1 Compartments The switchgear panel is assembled of standard prefabricated hot-dip zinc galvanized sheet steel units forming a rigid, free standing structure. The switchgear consists of the four compartments which are separated from each other by means of earthed metal partitions. Depending on circuit breaker draw-out unit, the two types of design are available: the cassette type and the truck type. Regardless of the type of draw-out unit, within the aspects of IEC related to the definition of Loss of Service Continuity, the design category of MILE MP series switchgear is defined as LSC2B-PM. Compartments of the MILE MP series switchgear are presented below: Busbar compartment MILE MP cassette type A - Busbar compartment B - Circuit Breaker compartment C - Low-voltage compartment D - Cable compartment MILE MP truck type The busbar compartment houses the main busbar system connected to the fixed upper isolating contacts of the circuit breaker by means of branch connections. The main busbars are made of electrolytic copper. The busbar compartment of each panel is segregated from the busbar compartments of the neighboring panels. Optionally the busbars can be covered with heat shrinkable insulation sleeves. It is possible for maintenance personnel to access the busbar compartment from the front side, as well as from the rear side of the switchgear Cable compartment The cable compartment houses the branch connections earthing busbar, earthing switch, power cables, surge arrestors, instrument transformers (current transformers, voltage transformers, zero-current transformers). The cable compartment design allows up to 4 cable per phase connections in case of withdrawable voltage transformer truck presence or 7 cable per phase in case of voltage transformer truck absence. Cable fixing plate is suitable to any kind of cable. Optionally the insulation partitions can be situated in cable compartment between phases. Insulation partitions are made from non-flammable material. In the bottom of the panel openings for control cables can be made if they enter from the cable tunnel. 10

11 Medium-Voltage Switchgear MILE MP12, MP17 and MP Circuit breaker compartment The circuit breaker compartment houses the bushing insulators containing fixed contacts for the connection of the circuit breaker to the busbars and to current transformers in the cable compartment. It includes all necessary interlocks for safety operation according to IEC standard and can be added other on request. The bushings are single-pole type and are made of cast resin. An access to the live parts is prevented with movable metal shutters. The metallic shutters operate automatically during movement of the circuit breaker from the test position to the service position or vice versa. They can be fixed in open or closed position by padlocks during maintenance. Circuit breaker compartment can be equipped with heaters. The position of the circuit breaker can be seen from the front of the panel through an inspection window Low voltage compartment The low-voltage compartment is designed to mount all secondary circuit connections within the single panel as well as interconnections between adjacent panels and transit connections. The spacious compartment allows the installation of multi-functional microprocessor protection relay, energy meters, lighting, heating and many other devices. 11

12 TECHNICAL MANUAL AND APPLICATION GUIDE 2.2 Withdrawable parts There are the following types of draw out units available: Vacuum Circuit Breaker Isolating truck Voltage Transformer truck Earthing Truck Draw out unit with CIRCUIT BREAKER (cassette/truck). The main purpose of a draw-out unit unit with circuit breaker is to make a visible break between the busbar and the cable compartment. It is needed for maintenance purposes in the cable compartment to guarantee personal safety. Also, it is used for comfortable service and testing of circuit breaker during commission of substation. The Draw out unit is equipped with all necessary interlocks for safety operation with panel in any condition. Draw out unit with ISOLATING TRUCK. Isolation truck is located in Bus Riser panel and used for making a visible break between sections of switchboard during maintenance procedures. Draw out unit with VOLTAGE TRANSFORMER TRUCK. A draw-out unit with voltage transformers is used for power metering of one feeder or the whole section and for providing voltage for protection devices. It can be placed in the circuit breaker or in the cable compartment. All voltage transformers can be equipped with striker type fuses to protect transformers against fault current. Draw out unit with CB, cassette type Draw out unit with CB, truck type Isolating truck Draw out unit with EARTHING TRUCK. An earthing truck is used for additional earthing of the switchgear. It do not have making capacity and provides only safety earthing during maintenance procedures. This truck is designed for busbar or cable earthing. Draw out unit with POWER CABLE TEST TRUCK. The truck is used for isolation tests of power cables without opening opening the cable compartment door and without disconnection of the cables from the switchgear. Withdrawable parts can easily be easily taken out or moved into panels with a specially designed adjustable ramp (service trolley). To establish the isolating (TEST) position inside the panel, the withdrawable part is moved on bearings by means of a worm-gear mechanism. The withdrawable parts are connected to the earth bar through a sliding contact arranged to make and maintain contact when it is in the Service, Intermediate and Test positions. Draw out unit with VT for circuit breaker compartment Draw out unit with VT for cable compartment 12

13 Medium-Voltage Switchgear MILE MP12, MP17 and MP Main busbars The busbar compartment contains the main busbar system connected to the fixed upper contacts of the circuit breaker compartment by means of branch connections. The main busbars are made of electrolytic copper. The maximum rating of busbar system with natural cooling is 3150A. With compulsory cooling the busbar's nominal rating can exceed 4000A. The busbars are normally covered with heat shrinkable sleeves for the voltage ratings exceeding 6kV. Each busbar compartment within the panel is segregated from the other by means of partitions and supported by pass through insulators. The through insulators have been tested for their capability to withstand stresses due to electro-dynamic forces at the rated breaking currents. 2.4 Branch connections The cable compartment contains the branch system for connection of the power cables to the fixed lower contacts of the circuit breaker compartment. The branch connections are made of electrolytic copper. The busbars are normally covered with heat shrinkable sleeves for the voltage ratings exceeding 12kV. Crossections of the main and of the branch busbars can be different depending on the values of rated currents. Main busbars Main busbars rated current, А Busbar, mm x mm x10x х10х x10x x10x Earthing busbar The earthing busbar is made of electrolytic copper with cross section 10x30mm. It runs along all adjacent panels and connects to a main earthing bar of substation. All current carrier parts are interconnected with each other to equipotential bonding to guarantee personal safety against electric shock. Branch busbars Branch busbars rated current, А Busbar, mm x mm 630 1х10х х10х х10х х10х х10х x10x x10x100 13

14 TECHNICAL MANUAL AND APPLICATION GUIDE 2.6 Bushing insulators and shutters The bushing insulators are located in the circuit breaker compartment, to hold fixed contacts and to be used for connection of the withdrawable unit to the busbar compartment and the cable compartment respectively. The bushing insulators are single-pole type and are made of cast resin. The shutters are made of metal and activated automatically during movement of the withdrawable unit from the test position to the service position or vice versa. 2.7 Cables Single and three-core cables up to a maximum of seven per phase and up to 4 cables with voltage transformers can be used depending on the rated voltages, panel dimensions and the cable cross section. The switchgear can be put the wall. 2.8 Automation and auxiliary wiring Electrical wiring diagrams are the part of switchgear documentation delivered to a customer. A complete set of wiring diagrams for a typical substation is available with ABB, Micom, VAMP, SEL protection relays or other manufacturers. On request, the wiring diagrams and consequently devices and instruments installed in switchgear can be customized to meet customer's specifications. A customer can benefit from the following options. Auxiliary supply voltage: V AC/DC Any type of a microprocessor protection relay can be adopted Solenoid and electromagnet interlocks for earthing switch, draw out units, sectional earthing switch Heating for every compartment, lighting SCADA readiness Arc protection variety selection Commercial metering Electrical drives for draw-out unit and earthing switch 14

15 Medium-Voltage Switchgear MILE MP12, MP17 and MP Pressure relief flaps and gas exhaust duct Pressure relief flaps allow hot gases to be extracted from the compartment in the event of internal arc. A pressure relief flap is mounted at the top of each power Up to 630А nominal current. Flat single sheet Pressure relief flaps design samples compartment of a panel. TEE has designed different versions of the flaps depending on required IP level, nominal currents and rated breaking currents. Over 630А nominal current. Multi edge construction The gas exhaust duct is presumed to evacuate hot gases into dedicated areas. The evacuation of hot gases and other harmful particles can be effected to: Neighbouring rooms Outside restricted areas Dedicated panel with extinguishing cameras equipped with special filters Upstream (special attention to the ceiling height) The gas exhaust duct is fitted at the top of each panel and runs along the whole length of the switchboard. The pressure generated by the internal arc makes pressure relief flaps open thus allowing hot gases to run into the special chimney to be evacuated to the dedicated areas. A complete solution for every installation is to be specified separately. 15

16 TECHNICAL MANUAL AND APPLICATION GUIDE 2.10 Doors The powder coated doors are made from galvanized steel sheets, it provides a rigid structure and resistance to mechanical stresses. Robust hinges and handles provide for convenient and safe closing. Inspection windows are made from explosion-proof glass providing maximal safety for personal Natural ventilation circuit Тhere is a natural ventilation circuit arranged around the circuit breaker to provide powerful extraction of the heat appearing due to circuit breaker operating at high currents or at high ambient temperatures. The cool air is sucked into the circuit, blown through the circuit breaker door and withdrawn from the panel through the gas exhaust channel. In case of internal arc blast, the reverse air current boosted by a high pressure instantly closes the special valve inside the shaft, thus preventing hot gases escaping from the panel Maintenance Basically the MILE MP series switchgear is made with front access, but on request it can be made with front and rear access. For the rear access type the additional interlock is installed for the door blocking if the earthing switch is open. For the convenient access to the current transformers, the rotating CT plate solution has been designed for cable compartment. 16

17 Medium-Voltage Switchgear MILE MP12, MP17 and MP24 3. Basic structure An indoor switchboard consists of different number and types of MP panels with switching devices, control and protection relays, signaling and metering devices and Cassette type other auxiliary equipment, which are interconnected by control cabling. The basic structures of the MP panels are given below. Truck type 1. Vacuum circuit breaker 8. Gas exhaust channel of the circuit breaker compartment 2. Primary contacts insulators 9. Gas exhaust channel of the busbar breaker compartment 3. Current transformers 10. Gas exhaust channel of the cable breaker compartment 4. Draw out unit with voltage transformers/fixed voltage transformers 11. Pressure relief flaps 5. Surge arresters 12. Support insulators with voltage indicator 6. Sealed cable entries 13. Shutter mechanism 7. Earthing switch 14. Main door with inspection window 15. Through insulators 17

18 TECHNICAL MANUAL AND APPLICATION GUIDE Cross - section: cassette type 1. Vacuum circuit breaker 15. Bushing insulators 2. Voltage transformer aux connector Earthing switch (make type) 3. Support insulator with a voltage indicator 17. Current transformers 4. Vacuum circuit breaker 18. Surge arresters 5. Circuit breaker aux connector 19. Outgoing cables 6. Live shutters 20. Bottom with sealed cable entries 7. Busbar earthing switch operation switch 21. Main earthing bar 8. Earthing switch control box 22. Earthing switch operation slot 9. Circuit breaker pressure relief flap 23. Ventilation provision 10. Operation mechanism for earthing switch 24. Cassette operation slot 11. Busbar compartment pressure relief flap 25. Circuit breaker emergency trip 12. Earthing switch top installation 26. Permission for operation with draw-out unit 13. Cable compartment pressure relief flap 27. Inspection window 14. Through insulator 18

19 Medium-Voltage Switchgear MILE MP12, MP17 and MP24 Cross - section: truck type 1. Truck for circuit breaker 15. Earthing switch (make type) 2. Support insulator with a voltage indicator 16. Current transformers 3. Vacuum circuit breaker 17. Surge arresters 4. Circuit breaker aux connector 18. Outgoing cables 5. Live shutters 19. Bottom with sealed cable entries 6. Busbar earthing switch operation switch 20. Main earthing bar 7. Earthing switch control box 21. Earthing switch operation slot 8. Circuit breaker pressure relief flap 22. Truck operation slot 9. Operation mechanism for earthing switch 23. Circuit breaker emergency trip 10. Busbar compartment pressure relief flap 24. Permission for operation with draw-out unit 11. Earthing switch top installation 25. Inspection window 12. Cable compartment pressure relief flap 13. Through insulator 14. Bushing insulators 19

20 TECHNICAL MANUAL AND APPLICATION GUIDE 3.1 Typical panels The available typical panels are presented below. The additional equipment or accessories for each panel can be coordinated within a certain order IF - Incoming feeder The Earthing Switch can be additionally interlocked with an electromagnet or electric drive from BC, BR, IF or upstream CB. Cassette version Truck version * - optional. ** - for truck type fixed voltage transformers only available. 20

21 Medium-Voltage Switchgear MILE MP12, MP17 and MP24 OF- Outgoing feeder Cassette version Truck version * - optional. ** - for truck type fixed voltage transformers only available. 21

22 TECHNICAL MANUAL AND APPLICATION GUIDE BC Bus Coupler BR Bus Riser * - optional. 22

23 Medium-Voltage Switchgear MILE MP12, MP17 and MP24 BRM - Bus-riser with metering transformer BRES - Bus-riser with earth switch * - optional. 23

24 TECHNICAL MANUAL AND APPLICATION GUIDE М - Metering panel MES - Metering panel with earth switch * - optional. 24

25 Medium-Voltage Switchgear MILE MP12, MP17 and MP24 LBSF - Load-break switch with fuses panel STP - Service transformer panel * - optional. 25

26 TECHNICAL MANUAL AND APPLICATION GUIDE 3.2 Top Installation Depending on requirements and structure of panel types in single line diagram the busbar earthing switch or voltage transformer can be installed over the top of any panel. Earthing switch in top installation can be equipped with support insulator with capacitor sensors and electromagnet for providing necessary interlocks. Earthing switch top installation Voltage transformer top installation Branch busbar 2 Support insulators 3 Earthing switch 4 Earthing switch mechanism 5 Socket for earthing switch operating tool 6 Openings for control cables 7 Voltage transformers 26

27 Medium-Voltage Switchgear MILE MP12, MP17 and MP24 4. EQUIPMENT 4.1 Cassette/Truck platform The following equipment can be istalled onto draw-out units depending on their functionality: circuit breaker, Voltage transformers, isolating truck. The equipment is fixed onto a metal support and handling cassette/truck platform. The cassette/truck platform is provided with a wheel system which makes the operations for racking the apparatus in and out of the switchgear possible with the door closed. The truck/cassette platform allows efficient earthing of the apparatus by means of the sliding earth busbar contact and the metal structure of the switchgear. The apparatus cassette/truck platform can be motor operated. The rack-in and rack-out operations can be carried out by means of electrical controls, either locally by an operator or by a remote system. + = Cassette Frame Truck type platform 4.2 Truck/Cassette circuit breaker Tavrida Electric has designed draw-out units ISM-DOU series for application in distribution networks with rated voltages 12-24kV 50/60Hz. These draw out units are based on ISM switching modules and intended for indoor applications in air-insulated switchgear of withdrawable design and MILE MP compatible cradles and power-boxes. ISM-DOU is completely type tested within metal-clad switchgear as per latest standards: IEC : High-voltage switchgear and controlgear Part 100: High-voltage alternating current circuit-breakers IEC : High-voltage switchgear and controlgear Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kv and up to and including 52 kv GOST 14694: Metal-clad switchgear up to 10 kv. Test methods. 27

28 TECHNICAL MANUAL AND APPLICATION GUIDE Abbreviation description ISMXX-DOU-XX-XX/XXX-XXX-xX Draw-out unit type Rated voltage, kv Draw-out unit Place of voltage transformers Short circuit current, ka Rated current, A Pole center distance, mm Draw-out unit interlock type Selection parameters Draw-out unit type ISM Circuit breaker; IT Isolation truck; VT Voltage transformer truck Rated voltage, kv 15 ( ) or 25 (24kV) Draw-out unit DOU Cassette; DOUT - Truck Place of voltage transformers CC VT in cable compartment; CB VT in circuit breaker compartment. Short circuit current, ka 16; 20; 25; 31,5; Rated current, A 630; 800; 1000; 1250;2000;2500;3150 Pole center distance, mm 150; 210; 250 Draw-out unit interlock type e1 version with electromagnet 110V e2 - version with electromagnet 220V m1 version with motor drive 110V m2 version with motor drive 220V *- LD circuit breaker type rated current is 630A is only. Example: ISM15-DOU-25/ e1 Draw-out unit type ISM Circuit breaker Rated voltage, kv 15 ( ) Draw-out unit DOU Cassette Short circuit current, ka 25; Rated current, A 2000 Pole center distance, mm 210 Draw-out unit interlock type e1 - version with electromagnet 110V VCB-DOU Selection table: Rated voltage/ PCD distance 12/17.5kV 150 PCD Rated currents 630A 1250A 2000A 2500A ISM15D-LD/1-150 ISM15D-HD/ /17.5kV 210 PCD ISM15D-HD/1-210 ISM15D-HD/ /17.5kV 275 PCD 24kV 210 PCD ISM25D-LD/1-210 ISM25D-HD/1-210 ISM15D-HD/ kV 275 PCD ISM25D-HD/

29 Medium-Voltage Switchgear MILE MP12, MP17 and MP ISM15-DOU-LD description 20kA; 1000A 150mm, 210mm LD Low Duty 1 Cable hose with auxiliary connector 2 Main contacts position indicator 3 Mechanical counter 4 Circuit breaker manual trip/locking tool 5 Emergency trip push button 6 DOU tool insert slot 7 Shutter actuator 8 Locking handles 9 Upper insulators 10 Movable contacts 11 Vacuum circuit breaker 12 Cassette position mechanical indicator 29

30 TECHNICAL MANUAL AND APPLICATION GUIDE ISM25-DOU-LD description 16kA; 800A 210mm, 275mm LD Low Duty 1 Cable hose with auxiliary connector 2 Main contacts position indicator 3 Mechanical counter 4 Circuit breaker manual trip/locking tool 5 Emergency trip push button 6 DOU tool insert slot 7 Shutter actuator 8 Locking handles 9 Upper insulators 10 Movable contacts 11 Vacuum circuit breaker 12 Cassette position mechanical indicator 30

31 Medium-Voltage Switchgear MILE MP12, MP17 and MP ISM15-DOU-HD Description 25kA, 31.5kA 630A, 1250A, 1600A, 2000A, 2500(3150)A 150mm, 210mm, 275mm HD High Duty Cable hose with auxiliary connector 2 Main contacts position indicator 3 Mechanical counter 4 Circuit breaker manual trip/locking tool 5 Emergency trip push button 6 DOU tool insert slot 7 Shutter actuator 8 Locking handles 9 Upper insulators 10 Movable contacts 11 Vacuum circuit breaker 12 Cassette position mechanical indicator

32 TECHNICAL MANUAL AND APPLICATION GUIDE ISM25-DOU-HD Description 25kA 630A, 1250A 210mm, 275mm HD High Duty 1 Cable hose with auxiliary connector 2 Main contacts position indicator 3 Mechanical counter 4 Circuit breaker manual trip/locking tool 5 Emergency trip push button 6 DOU tool insert slot 7 Shutter actuator 8 Locking handles 9 Upper insulators 10 Movable contacts 11 Vacuum circuit breaker 12 Cassette position mechanical indicator 32

33 Medium-Voltage Switchgear MILE MP12, MP17 and MP ISM15-DOUT-HD Description 25kA, 31.5kA 630A, 1250A, 1600A, 2000A, 2500(3150)A 150mm, 210mm, 275mm, HD High Duty 1 Cable hose with auxiliary connector 2 Main contacts position indicator 3 Mechanical counter 4 Circuit breaker manual trip/locking tool 5 Emergency trip push button 6 DOU tool insert slot 7 Shutter actuator 8 Locking handles 9 Upper insulators 10 Movable contacts 11 Vacuum circuit breaker 12 Cassette position mechanical indicator 13 Frame for cassette 14 Wheels 33

34 TECHNICAL MANUAL AND APPLICATION GUIDE VT-DOU Desctription IT-DOU Description 1 Voltage transformers 2 - Cable hose with auxiliary connector 3 Cassette 4 Secondary circuits terminals 5 Movable contacts 6 Support Insulators 7 - Shutter actuator 34

35 Medium-Voltage Switchgear MILE MP12, MP17 and MP Circuit breaker Presentation The withdrawable versions of TEL circuit breakers are based on ISM and CM modules. These modules are based on the latest switching and electronic control technology can be used as the core components of medium voltage switchgear. There are two basic module types: switching modules (ISM) are used to close and open primary circuits control modules (CM) are used to provide control (close and trip operations) of ISM Switching modules are three pole units. Each pole incorporates a vacuum interrupter and single-coil magnetic actuator encapsulated in solid insulation. Control modules are microprocessor-based electronic units, containing built-in close and trip capacitors. The close and trip capacitors can be discharged onto the actuator coil to provide appropriate operations. The ability to choose switching and control modules separately allows any type of switchgear to be easily configured with regard to its primary and auxiliary circuits. TEL modules have been the product of many years of R&D effort by Tavrida Electric scientists and engineers and their utilization in MILE switchgear will allow customers to benefit from their unique combination of features: no maintenance needed during its entire lifetime long mechanical and interrupting life fast autoreclosing capability low power consumption light weight 35

36 TECHNICAL MANUAL AND APPLICATION GUIDE Overall design In contrast to the majority of conventional circuit breakers, this patented design incorporates three independent magnetic actuators: one per pole. This minimizes the number of moving parts and makes all of these parts coaxial. The vacuum interrupter and the magnetic actuator are located at opposite ends of a hollow support insulator. The actuator armature is rigidly coupled to the vacuum interrupter moving contact by a linear drive insulator within the support insulator. This provides direct linear movement in both directions and avoids the use of rotating shafts, bearings and bell cranks. The result is a maintenance free ISM with a long trouble-free mechanical life. The actuators are situated inside the frame as shown in the figure below. A synchronizing shaft connects the three poles and performs three functions: Magnetic actuator The actuator is held in its two end positions without the use of mechanical latches: in the OPEN position the armature is held by the opening spring in the CLOSED position the armature is held by the magnetic flux produced by a ring magnet This actuator has only one coil. To close and trip the actuator it is necessary to inject current into the coil in different directions. opening synchronization of the poles operation of auxiliary switches link drive for mechanical interlocks on switchgear LD (low-duty) ISM circuit breaker pole cross-section 34

37 Medium-Voltage Switchgear MILE MP12, MP17 and MP24 HD (high-duty) ISM circuit breaker pole cross-section Support insulator Upper terminal Vacuum interrupter Crown-type flexible contact Lower terminal Pulling insulator Stator of actuator Actuator coil Main contacts position indicator actuator Armature of actuator Opening and additional contact pressure springs Interlocking shaft Auxiliary terminals Sinchronizing shaft 37

38 TECHNICAL MANUAL AND APPLICATION GUIDE Vacuum interrupters As soon as the vacuum interrupter contacts open, the interrupting current initiates a so-called "vacuum arc" that burns essentially as plasma originating from evaporated contact material. The current continues to flow through this plasma until a zero current is reached. At this moment the arc is extinguished and a transient recovery voltage appears across the open gap. If the contact surface is locally overheated, it produces a lot of vapour, resulting in the deterioration of the vacuum followed by an electrical breakdown. To avoid this, effective control of the vacuum arc is necessary. The most effective way to achieve this goal is to apply an The family of TEL vacuum interrupters axial magnetic field produced by the interrupting current itself. This method is implemented in vacuum interrupters developed and manufactured by Tavrida Electric for ISM modules. Several major benefits result from this design: high interrupting capacity very compact dimensions low chopping current (4-5 amps) This limits inductive switching overvoltages to safe values axial magnetic field minimizes contact erosion and ensures a very long and reliable life Finely dispersed vacuum arc resulting from stabilizing effect of axial magnetic field 38

39 Medium-Voltage Switchgear MILE MP12, MP17 and MP Control modules Description Code Remarks Picture Control Module СM_12_1(220) 110,220VDC VAC Control Module СM_12_1(60) 24, 48, 64VDC Control Module СM_12_2(220) 110,220VDC VAC Control Module СM_12_2(60) 24, 48, 64VDC Control Module СM_12_3(220) 110,220VDC VAC Control Module СM_12_3(60) 24, 48, 64VDC Control Module СM_15_1(230) 110,220VDC VAC Control Module СM_15_1(60) 24, 48, 64VDC Manual generator SS30-WA 110VDC 39

40 TECHNICAL MANUAL AND APPLICATION GUIDE 4.5 Current transformers The support type current transformers are used to provide current information from line to protection relays, control systems and power metering devices. All current transformers are manufactured with barriers. All active parts are solidly and made from cast resin. It performs good electrical insulating and supporting functions. All current transformers comply with IEC , GOST and DIN The MILE switchgear is designed for mounting all types of manufactures of support type current transformers. 4.6 Voltage transformers The voltage transformers are used to provide voltage information from line to protection relays, control systems and power metering devices. All active parts of transformer are solidly insulated with cast resin. This material performs both the electrical insulating and the mechanical functions. Voltage transformers designed for fixed installation or mounting on withdrawable truck in the switchgear. Both types can be equipped with protection fuses with striker system. This system gives possibility to send a signal of the fuse fault into SCADA. Fixed voltage transformers can be installed directly on the main busbar system on the top of switchgear. The transformers comply with IEC , GOST and DIN Zero sequence current transformer The zero sequence current transformers are used for measuring phase currents or detect earth fault currents. They made of solidly insulated with cast resin. Transformers can be mounted inside of a panel or fitted to the bottom of switchgear in cable tunnel. 40

41 Medium-Voltage Switchgear MILE MP12, MP17 and MP Earthing switch Each panel can be fitted with an earthing switch for cable earthing. The same device can also be used to earth the busbar system in metering or bus couplier panel. On request the busbar earthing switch can be mounted on the top of switchgear. The earthing switch has short-circuit making capacity. Operation with earthing switch is arranged from the front of switchgear and can be manual or motor operated. The position of the earthing switch can be determined from the front of the switchgear by means of a mechanical indicator. For the applications of front and rear access panel, the position of the earthing switch can also be determined from the rear of the panel by means of mechanical position indication through an inspection window. The earthing switch conforms with IEC standard. Earthing switch have 6NO+4NC auxiliary contacts for position indication 4.9 Surge Arresters On request the switchgear can be equipped with surge arresters. They are used for protection panel against lightning and commutation overvoltages andinstalled in the cable compartment. Surge arresters conform with IEC and GOST standards. Auxiliary contacts of earthing switch 41

42 TECHNICAL MANUAL AND APPLICATION GUIDE 4.10 Cassette type to truck type transformation The basic design of the MILE MP/TEE panel is identical for both cassette and truck types. There are only four parts that differ between cassette and truck type panels. front doors, intermediate plate, cable compartment covers special floor slides. The cassette type panel can be easily transformed into the truck type panel. The truck type VCB has the same cassette draw-out unit installed onto a special floor-rolling cassette extension. The cassette VCB can be easily transformed into truck type VCB by fixing it with the 4 bolts onto cassette extension. The pictures of the cassette and truck type VCBs are shown below. Cassette To transform the cassette type panel into truck one the 4 steps should be taken. Truck type Remove cable and circuit breaker compartment doors. 42

43 Medium-Voltage Switchgear MILE MP12, MP17 and MP24 Remove the intermediate plate. Fix the floor slides and cable compartment covers. Mount a single door. To transform from truck type to cassete type panel should be done the same operation but backward. 43

44 TECHNICAL MANUAL AND APPLICATION GUIDE 5. INTERLOCKS AND LOCKING DEVICES The switchgear is fitted with all interlocks needed to guarantee the highest level of safety for operators. According to IEC the interlocking devices prevent: racking-in of the circuit breaker while the earthing switch is closed closing of the earthing switch when the circuit breaker is in the connected or intermediate positions opening of the cable compartment door while the earthing switch is open opening of the earthing switch while the circuit breaker compartment door is open In addition, if a panel is equipped with an earthing switch, the interlocking devices prevent: closing of a circuit breaker in the intermediate position racking-out of a circuit breaker in the closed position racking-in of a circuit breaker in the closed position opening of the circuit breaker compartment door as long as the circuit breaker is not in the test position racking-in of the circuit breaker while the compartment door is open Cable and circuit breaker department doors can be locked by means of padlocks. The operations of circuit breaker racking-in/out and earthing switch opening/closing can be prevented by applying the padlocks or castle lock to the corresponding openings or slots. The metal shutters can be locked by means of two independent padlocks in both the open and the closed positions. 44

45 Medium-Voltage Switchgear MILE MP12, MP17 and MP24 6. TECHNICAL SPECIFICATIONS The rated characteristics of the switchgear are guaranteed under the following ambient conditions: In accordance with standard. Parameter Parameter value Minimum ambient temperature - 40 C* Maximum ambient temperature +40 C (on request +55 C) Maximum altitude above sea level 3000 m ** Relative humidity 95% Ambient atmoshpere Presence of normal, non-corrosive and uncontaminated atmosphere. The panel operation environment must not have dust, particles, fumes or smoke, corrosive or flammable gases, vapors or salts. * with selected microprocessor electronics only. ** in accordance with IEC for altitudes above 1000 m, it is required to take into consideration the decrease of dielectrical strength applying factor from the table. The MILE MP series switchgear are suitable for operation in the climate of Wda type in accordance with IEC standard. 45

46 TECHNICAL MANUAL AND APPLICATION GUIDE Main technical data: Rated voltage, kv 12 17,5 24 Rated insulation voltage, kv 12 17,5 24 Rated frequency, Hz 50/60 50/60 50/60 Rated power frequency withstand voltage, 1 min, kv Rated lightning impulse withstand voltage, kv Rated branch connection current, А 630;1000;1250; 1600;2000;2500; ;1000;1250; 1600;2000;2500; ;1000;1250; 1600;2000 Rated main busbar current, А 1250;2000; ;2000; ;2000 Rated breaking current, ka 25; 31,5 25; 31,5 25 Rated short-time withstand current (3 s), ka 25; 31,5 25; 31,5 25 Rated peak withstand current, ka 64; 83 64; Rated supply voltage for auxiliary circuits, V DC 48; 110; ; 110; ; 110; 220 AC 100; ; ; 230 Insulation level Normal Normal Normal Insulation type Air Air Air IAC classification (IEC ) AFLR 31,5kА/1s AFLR 31,5kА/1s AFLR 25kА/1s Busbar insulation Partly-insulated Insulated Insulated Maintenance version Front; front/rear access Front; front/rear access Front; front/rear access Control versions Local and RTU Local and RTU Local and RTU Height Width, mm 600 Up to 1250A Up to 1250A A A A A A A Depth Class of protection IP 4X (IP 41 on request) IP 4X (IP 41 on request) IP 4X (IP 41 on request) 46

47 Medium-Voltage Switchgear MILE MP12, MP17 and MP24 7. OVERALL DIMENSIONS Voltage Width, A mm Depth, B mm Height, C mm 12kV 600, 750, ,5kV 600, 750, kV 750, ,5 kv Depth (mm) 1350 Height (mm) 2200 Width (mm) Weight (kg) Rated current (A) IF OF BC BR BRES M MES LBSF* 24 kv Depth (mm) 1560 Height (mm) 2200 Width (mm) Weight (kg) Rated current (A) IF OF BC BR BRES M MES LBSF* STP* STP* *STP and LBSF cubicle maximum ratings are 630A 47

48 TECHNICAL MANUAL AND APPLICATION GUIDE APPLICATION GUIDE This guide provides instructions for installation and use of the switchgear. 8. SELECTION 8.1 Selection description MILE MP-XX-XX/XXX-XXX-X-XXX MILE type panel Rated voltage, kv Rated breaking current, ka Branch busbars rated current, A Type of panel Main busbars rated current, A Width, mm Selection parameters: Rated voltage, kv 12, 17.5, 24 Rated breaking current, ka 20; 25; 31.5 Rated current, A 630; 1250; 1600; 2000; 2500(3150) Type of panel IF, OF, BC, BR, BRM, BRES, M, MES, LBSF, STP Main busbars rated current, A A-1250, B-2000, C-2500(3150) Width, mm 600, 750, 1000 Example: MILE MP /2000-OF-B-750 Rated voltage, kv 17.5 Rated breaking current, ka 25 Rated current, A 2000 Type of panel OF Main busbars rated current, A 2000 Width, mm

49 Medium-Voltage Switchgear MILE MP12, MP17 and MP24 9. INSTALLATION 9.1 Packaging, handling, storage Packaging Handling of panel and withdrawable part: Each panel is delivered vertically, in separate packaging. State of the equipment before packaging: withdrawable parts are removed. earthing switch closed. The packaging of panel for road transport: enveloped in plastic stretch wrapping (thickness > 100μ), belted with sticky tape. The packaging of panel for air and sea transport: enveloped in plastic stretch wrapping (thickness > 100μ), packed in wooden crates. Withdrawable parts (circuit breakers, isolating trucks, voltage transformer trucks) are contained in wooden crates. Additional equipment and spare parts packed separately or together in one package. It is important that the forks of the truck are fully engaged throughout the entire width of the wooden crate. The weights of the crates are indicated on their sides. In order to lift or deposit crate use a jib crane. Fix lifting lugs only to the indicated points. Never tip the crates over. Never handle the circuit breaker by its contact parts. Never lift circuit breaker by lifting it under its chassis or under its trolley. Four points are provided for connection of lifting lugs on the sides of each panel. 49

50 TECHNICAL MANUAL AND APPLICATION GUIDE Storage Panels must be stored indoors. The storage area must be free of dust particles, fumes or smoke, corrosive or flammable gases, vapors or salts. Lift the panel unit by 4 lifting lugs. Slide the panel, using three cylindrical rollers of 30 mm min. diameter. 9.2 Unpacking and installation of the equipment Foundation surface 41 The installation of a switchboard requires a flat, concrete structure. The following requirements to the floor surface must be obeyed: Evenness tolerance: ± 1mm within a measuring length of 1m Straightness tolerance: 1mm per 1m, but not more than 3mm over entire length of frame. Floor, ceiling and walls of the building must be finished with materials, which do not raise or collect dust Unpacking panels Use special provisions on withdrawable units for lifting. All lifting, towing equipment must be in good condition, checked, regularly inspected according to national safety rules. Always lift the equipment in a balanced mode. Unpacking panels should only take place on the installation site. Remove plastic stretch wrapping from the panel. Visually inspect the exterior of panel. 50

51 Medium-Voltage Switchgear MILE MP12, MP17 and MP Panels installation, fixing and positioning Panels must be positioned on the site in accordance with developed and approved civil project and electrical diagram. The openings on the floor for passage high-voltage cables must be provided. The openings for the passage of the low-voltage cables must be reserved as shown on the picture. The openings for the passage of the low-voltage cables must be reserved as shown on the picture. 1 Passage for high-voltage cables 2 Opening 60x200 for passage of low-voltage cables (Optional) 3 Fixing places with floor by anchor bolts 51

52 TECHNICAL MANUAL AND APPLICATION GUIDE The panel must be positioned as shown in the picture: a. Back-to-wall positioning. Front access. b. Front and rear access. A Depth of switchgear B - Width of switchgear A special attention to the height of substation ceiling must be taken into consideration due to the requirements for passive arc protection. 52

53 Medium-Voltage Switchgear MILE MP12, MP17 and MP24 Depending on short-circuit current levels and application of gas exhaust chimney the following table must be considered for selection of ceiling height of the substation. Rated short cicuit current 20kA 25kA 31.5kA Arcing time 0.5 sec 1 sec 0.5 sec 1 sec 0.5 sec 1 sec Ceiling height without gas exhaust chimney (H) Ceiling height with gas exhaust chimney (H) The exit area for hot gases evacuation must be chosen carefully with the consideration of the following points: The area must be restricted for access of personnel The area must be clearly indicated H>2,8 m H>3 m H>3 m H>3,5 m H>3,5 m H>4 m H>2,8 m H>2,8 m H>2,8 m H>2,8 m H>2,8 m H>2,8 m The hot gases must not harm the equipment or machinery located nearby The access of water, animals, and small objects into the exhaust chimney must be prevented 9.4 Positioning panels in a switchboards Panels must be positioned in accordance with the single-line diagram. If switchboard is composed of 1-10 panels, it is recommended to begin installation from the first panel, counting from a side opposite to the room entry. If switchboard is composed of more than 10 panels, then begin the installation from the middle of the switchboard. Panels are to be interconnected by M8 bolts in 8 fixing points. 9.5 Connecting panels Panels Panels fixing points Make sure that all panels are perpendicular in relation to the floor surface. Align up the front facing panels. Proceed with the layout of the other panels by repeating the same checks each time. 53

54 TECHNICAL MANUAL AND APPLICATION GUIDE Main busbar Before the assembling of main busbar on substation, the connection surface must be cleaned by wire brush for better electrical contact. Position connection places and fix them together with the help of 4xМ12х65 bolts. Main busbar Recommended tightening torques for busbar bolt connection: Bolt connection size Tightening torque without lubricant, Nm Tightening torque with lubricant, Nm M6 10,5 4,5 M M10 44,1 30 M12 74,6 40 M M Bolt connection Branch busbar Earthing busbar The earthing bar is inserted into the cable compartment through the special rectangular openings and fixed by bolt M8x45. Make sure that contact surface of earthing busbar is flat and clean. Connection between earthing busbar of panels and main earthing bar of substation must be done according to maximum earth-fault current of switchgear. Adjoin the earth busbar to the connection point and fix with M12 bolt. 54

55 Medium-Voltage Switchgear MILE MP12, MP17 and MP Control cables interconnection The interconnection between panels is realized by the control cables through openings in both sides of the low voltage compartment. For connection with external devices (DC distribution board or SCADA) the openings are provided from the top and from the bottom of the cable compartment. Opening for transit cables 9.6 Fixing the cables Before connection the cables make sure that cables are without voltage, the CB is in OPEN position and the earthing switch is in CLOSED position. Cable fixations Cable glands 55

56 TECHNICAL MANUAL AND APPLICATION GUIDE 10. OPERATION 10.1 Withdrawable Parts Position Definitions Service position Main circuits are connected Auxiliary circuits are connected The circuit breaker can be CLOSED and OPENED The circuit breaker compartment door is closed and cannot be opened Intermediate position The withdrawable part is between the service and the test positions Auxiliary circuits are connected The circuit breaker is OPENED and interlocked The circuit breaker compartment door is closed and cannot be opened Test position Main circuits are disconnected Auxiliary circuits are connected The circuit breaker can be CLOSED and OPENED for testing purposes The circuit breaker compartment door can be opened and closed Isolated position Main circuits are disconnected Auxiliary circuits are disconnected The circuit breaker cannot operate The circuit breaker compartment door is open and cannot be closed Removed position The withdrawable part is physically removed from the panel 10.2 Interlocking Conditions It shall not be possible to rack out the withdrawable part from the service position to the test position when the circuit breaker is CLOSED. Similarly, it shall not be possible to rack in the withdrawable part from the test position to the service position, if the circuit breaker is CLOSED. Any attempt to rack out the withdrawable part from the service position to the test position shall not result in TRIPPING of the Circuit Breaker. It shall not be possible to rack in or rack out the withdrawable part when the circuit breaker compartment door is open. It shall not be possible to rack in the withdrawable part from the isolated position to the service position when the low voltage control plug is not connected. Similarly, it shall not be possible to close the circuit breaker compartment door in the isolated position unless the low voltage control plug is connected. It shall only be possible to CLOSE the earthing switch if provided, when the withdrawable part is in the test position. This ensures physical isolation between the withdrawable part and the busbar and cables. It shall not be possible to rack in the withdrawable part from the test position to the service position, in case the cable earthing switch is CLOSED. It shall not possible to operate the circuit breaker when the breaker is in the intermediate position between the service position and the test and vice versa. Additionally, an electro-magnetic interlock shall be provided for earthing switches of incomer and coupler panels. Alternately earthing trucks can be supplied with the electro-magnetic interlock. 56

57 Medium-Voltage Switchgear MILE MP12, MP17 and MP24 Conditions to be met Operations CB CB in Feeder Earthing Switch with Mechanical Interlock Test Position - CB closing Test Position - CB opening Service Position - CB closing Service Position - CB opening CB Moving from Service position to Test position Test position to Service Position Feeder Earthing Switch Open Closed Test Position X X X X Service Position Respective Busbar Earthing Switch Circuit breaker compartment Door with Mechanical Interlock Open Closed Open Closed Open Closed X X X* X X* X X X* X X* X X* X X* X X* X X* Closing X X X X** Opening X X X X** Bus Earthing Switch Closing X X X X Opening X X X X LV Plug Disconnecting X X X Connecting X X X X - Conditions to be met * - Mechanical Interlock ** - mechanical interlock related to the cable compartment door for the cassette version Interlock mechanisms Standard supply The basic set of interlocks provides electrical and mechanical interlocks of the following operations according to IEC Operation of the circuit breaker (CLOSE/TRIP) Operation of the DOU (rack in/out) Operation of the earthing switch (CLOSE/OPEN) The interlocks are provided by the design of the withdrawable part and earthing switch mechanisms. 57

58 TECHNICAL MANUAL AND APPLICATION GUIDE Optional supply The optional mechanisms presented in the picture below can be installed on request: Interlock 1 It is prohibited to close the circuit breaker compartment door when the circuit breaker connector is not inserted. If control circuit connector is not inserted, then lever (1) is in horizontal position and blocks the door's closing, which is shown by a fluorescent red sticker. (2). To close the door the service personnel must push lever down, free access to socket and insert plug. The same interlock is used in cable compartment when draw out unit with voltage transformers is installed. Interlock 2 It is prohibited to open the cable compartment door if the earthing switch operation tool is inserted. If the earthing switch operation tool is inserted then the earthing mechanism's cover (3) blocks to open the cable compartment door. To open the door, the earthing switch operation tool should be removed from the earthing mechanism. Interlock 3 It is prohibited to rack-in the circuit breaker if the earthing switch is CLOSED. When the earthing switch is in CLOSED position the locking shaft (4) withdraws to slide a joint mechanism and forbids the circuit breaker's racking-in. Interlock 4 It is prohibited to open the cable compartment door when the earthing switch is OPEN. When the earthing switch is OPEN the locking shaft fix the door hook (5) in opening (6). To open the cable compartment door turn the operating tool counter clockwise and CLOSE the earthing switch. The locking shaft slides upwards the releasing the hook. 58

59 Medium-Voltage Switchgear MILE MP12, MP17 and MP24 Interlock 5 It is prohibited to rack-in or rack-out the withdrawable part when the circuit breaker is CLOSED. To rack in or rack out withdrawable part it is needed to turn the permission key for operation with draw-out unit (6) counterclockwise to 90. It opens access to the rack-in mechanism (7). If the circuit breaker was CLOSED during turning key (6), interlock trip the circuit breaker to prevent danger situation. Interlock 6 The DOU movement from the test position to the service position is prohibited unless the circuit breaker compartment door is closed. With the door closing the door hook (8) presses on the DOU engaging slide, which releases the DOU operating mechanism. Interlock 7 It is prohibited to operate the earthing switch when cable compartment door is open. When closing the door the blade fits into an opening, releasing a locking pin (9) which allows access to the earthing switch slot. When the door is opened the locking pin is engaged. Interlock 8 The circuit breaker compartment door opening is prohibited unless DOU is not in the test position. After DOU started racking in, the end of the bracket engaged by the shutters mechanism moves downward and blocks the door hook. 59

60 TECHNICAL MANUAL AND APPLICATION GUIDE 10.4 Locking facilities A standard double bit key lock can be used for locking DOU in the test and service positions. The earthing switch can be locked with a padlock. Live shutters can be securely locked in the open and closed positions with a padlock. The access to the circuit breaker or cable compartments can be restricted with the padlocks or key-locks (optionally) Interlock between panels (optional) The busbar earthing switch can only be closed when all the withdrawable parts of a relative busbar section are in the test position (electromechanical interlock ) When the busbar earthing switch is closed, the withdrawable parts of the earthed busbar section cannot be moved from the test position to the service position (electromechanical interlock) 60

61 Medium-Voltage Switchgear MILE MP12, MP17 and MP Circuit breaker panel (IF, OF, BC) VCB READY PROTECTION RELAY REMOTE/LOCAL SWITCH EMERGENCY TRIP VOLTAGE INDICATOR Table with switchgear technical parameters Inspection window Socket for draw out unit interlock Emergency trip push button Socket for operation with draw-out unit Socket for operation with earthing switch Ventilation canal 61

62 TECHNICAL MANUAL AND APPLICATION GUIDE Operations with draw-out unit Accessories: Key 1 for interlock draw-out unit Operations with earthing switch Accessories: Key 3 Tool for operation with earthing switch Key 2 For rack-in and rack-out draw-out unit AT T E N T I O N! F O R O P E R AT I O N W I T H EARTHING SWITCH DRAW-OUT UNIT MUST BE IN TEST POSITION! Switching ON DRAW-OUT UNIT MOVEMENT CAN BE DONE ONLY WHEN EARTHING SWITCH IS OPEN! Draw-out unit movement from TEST to SERVICE position and switching circuit breaker 1. Close the door. 2. Push emergency trip button to guarantee that circuit breaker is open. 3. Socket for draw-out unit interlock: Plug key 1 to draw-out unit interlock socket and turn to 90 counterclockwise to release access to draw-out unit operation socket. 4. Socket for draw out unit operation: Plug key 2 to draw-out unit operation socket and turn it 20 times clockwise. 5. Turn key 1 to 90 clockwise to permit operation with circuit breaker. 6. Take out key 1 from draw-out unit interlock socket 7. Circuit breaker is ready for service. Draw-out unit movement from SERVICE to TEST position 1. Open cover of earthing mechanism. 2. Push the tag downward and insert earthing switch tool (3). 3. Turn tool to 180 clockwise to CLOSE earthing switch. 4. Pull earthing switch tool back to open cable compartment door. Switching OFF 1. Close cable compartment door. 2. Open cover of earthing mechanism. 3. Push the tag downward and insert earthing switch tool (3). 4. Turn tool to 180 counterclockwise to OPEN earthing switch. 5. Pull earthing switch tool back. 1. Switch off circuit breaker. 2. Socket for draw-out unit interlock: Plug key 1 to draw-out unit interlock socket and turn to 90 clockwise to release access to draw-out unit operation socket. 3. Socket for draw out unit operation: Plug key 2 to draw-out unit operation socket and turn it 20 times counterclockwise. 4. Draw-out unit is in TEST position. Door can be opened. ATTENTION! IF CIRCUIT BREAKER IS CLOSED, TURNING KEY 1 TO 90 COUNTERCLOCKWISE WILL LEAD TO EMERGENCY TRIPPING OF CIRCUIT BREAKER. 62

63 Medium-Voltage Switchgear MILE MP12, MP17 and MP Metering panel (MES) VOLTAGE INDICATOR Table with switchgear technical parameters Inspection window Socket for draw out unit interlock Socket for operation with draw-out unit Socket for operation with earthing switch Ventilation canal 63

64 TECHNICAL MANUAL AND APPLICATION GUIDE Operations of draw out unit with voltage transformer Accessories: Key 1 for interlock draw-out unit Operations with busbar earthing switch Accessories: Key 3 Tool for operation with earthing switch Key 2 For rack-in and rack-out draw-out unit DRAW-OUT UNIT MOVEMENT CAN BE DONE ONLY WHEN EARTHING SWITCH IS OPEN! Draw-out unit with VT movement from TEST to SERVICE position 1. Close the door. 2. Socket for draw out unit interlock: Plug key 1 to draw-out unit interlock socket and turn to 90 counterclockwise to release access to draw-out unit operation socket. 3. Socket for draw out unit operation: Plug key 2 to draw-out unit operation socket and turn it 20 times clockwise. 4. Turn key 1 to 90 clockwise to permit operation with circuit breaker. 5. Take out key 1 from draw-out unit interlock socket. Draw-out unit with VT movement from SERVICE to TEST position 1. Socket for draw-out unit interlock: Plug key 1 to draw-out unit interlock socket and turn to 90 clockwise to release access to draw-out unit operation socket. 2. Socket for draw out unit operation: Plug key 2 to draw-out unit operation socket and turn it 20 times counterclockwise. 3. Draw-out unit is in TEST position. Door can be opened. AT T E N T I O N! F O R O P E R AT I O N W I T H EARTHING SWITCH DRAW-OUT UNIT MUST BE IN TEST POSITION! FOR OPERATION WITH BUSBUR EARTHING SWITH IN METERING PANEL, ALL DRAW OUT UNITS OF WHOLE SECTION MUST BE IN TEST POSITION. Switching ON 1. Open cover of earthing mechanism. 2. Push the tag downward and insert earthing switch tool (3). 3. Turn tool to 180 clockwise to CLOSE earthing switch. 4. Pull earthing switch tool back to open cable compartment door. Switching OFF 1. Close cable compartment door. 2. Open cover of earthing mechanism. 3. Push the tag downward and insert earthing switch tool (3). 4. Turn tool to 180 counterclockwise to OPEN earthing switch. 5. Pull earthing switch tool back. 64

65 Medium-Voltage Switchgear MILE MP12, MP17 and MP Load-break switch feeder LBSF Socket for operation with load break switch 1 put the operating lever on the mechanism s shaft; 2 pull back the operation sleeve; 3 close or open switch disconnector depend on its present position Socket for operation with earthing switch The load break switch is mechanically and electrically interlocked with earthing switch Operations with load break switch 1. Put the operation lever to mechanism shaft. 2. To switch ON, turn operation lever 180 clockwise. 3. To switch OFF, turn operation lever 180 counterclockwise Operations with earthing switch 1. Put the operation lever to red mechanism shaft. 2. To switch earthing switch ON, turn operation lever 180 clockwise. 3. To switch OFF, turn operation lever 180 counterclockwise. 65

66 TECHNICAL MANUAL AND APPLICATION GUIDE 10.9 Service trolley operation For the convenience of transportation, inserting and withdrawal of all types of DOUs, TEE has designed a Service Trolley. It is intended for application for both the circuit breaker compartment and the cable compartment DOUs. The service trolley has 2-level adjustable ramps. The upper ramp is used for operations with the circuit breaker compartment DOUs, the lower ramp is used for the cable compartment DOUs. The service trolley is equipped with four wheels with stoppers for moving on the floor surface, hardened handles, and a self-locking mechanism which guarantees secure coupling of the trolley and the MILE switchgear during inserting and withdrawal operations. Both DOUs the circuit breaker and the voltage transformer trucks can be moved at once. Both DOUs are secured with sliding locks during their transportation on the trolley. The MILE switchgear interface for operation of the Service trolley is shown in the picture. Openings for trolley guides Trolley guides 66

67 Medium-Voltage Switchgear MILE MP12, MP17 and MP24 Circuit breaker compartment ramp Openings for sliding locks Service trolley handle fixator Adjustment facilities for the upper ramp Hardened handles Place for tools or voltage transformer ramp Voltage transformer ramp 57 Trolley guides Wheels 67

68 TECHNICAL MANUAL AND APPLICATION GUIDE Moving DOU from the removed position to the isolated position Adjust DOU on the service trolley Open the door of the switchgear Move the trolley close to the panel Position trolley in such a way that trolley guides are directed into the guide openings of the panel. Adjust the height of the ramp, if needed Push the trolley forward until the trolley guides clicks in. The trolley is secured In order to release DOU, slide 2 handles simultaneously to the middle Holding the DOU handles push DOU into the compartment until it gets stuck Release DOU handles. The DOU fixing blades must move into the special slots in the panel and reach the end position. Unless the DOU fixing blades are not placed correctly no operations of the DOU are possible inside the panel In order to remove the service trolley, release it by pressing downward the fixator handle and moving the trolley back at the same time When the trolley is removed, DOU is in the isolated position Position trolley guides directed into the guide openings Slide 2 handles simultaneously to the middle Push DOU into the compartment until it fixes DOU is in the test position 68

69 Medium-Voltage Switchgear MILE MP12, MP17 and MP Moving DOU from the isolated position to the removed position Open the door of the switchgear Disconnect the auxiliary plug. The DOU is in the isolated position Move the trolley close to the panel Position trolley in such a way that trolley guides are directed into the guide openings of the panel. Adjust the height of the ramp, if needed. Push the trolley forward until the fixator clicks. The trolley is secured. In order to release DOU from the compartment, slide 2 handles simultaneously to the middle Pull DOU backward on the trolley ramp until the DOU fixing blades click in Release DOU handles. The DOU fixing blades must move into the special slots of the trolley and reach the end position In order to remove the service trolley, press fixator handle downward and move the trolley back at the same time When the trolley is removed, the DOU is in the removed position Position trolley guides directed into the guide openings Slide 2 handles simultaneously to the middle Pull DOU backward on the trolley ramp until the DOU fixing blades click in DOU is in the removed position 69

70 TECHNICAL MANUAL AND APPLICATION GUIDE Set of tools DOU operation tool Key for interlock of draw out unit Earth switch operation tool Troubleshooting Malfunction Possible origin Solution Cannot open the cable compartment door Earthing switch is open Check if the earthing switch is open by the indicator or through the reer window. Close the earthing switch (see chapter ). Cannot open the CB compartment door CB is not in the test position Check the DOU CB position (indicator, inspection window), move DOU CB to the test position (see chapter ). Cannot close CB compartment door Low voltage plug of DOU is not inserted Сheck the position of low voltage plug of DOU, insert it. Cannot rack in the CB CB is closed Check the condition of CB, open it. CB compartment door is open Earthing switch is closed Check the position of the door, close the door. Check the position of the earthing switch, open it (see chapter ). Cannot rack out the CB CB is closed Check the condition of CB, open it. Cannot close the earting switch Cannot open the earthing switch CB in service or intermediate position The cable compartment door is open Check the position of CB, move it to the test position (see chapter ) Check the position of cable compartment door, close it. Cannot close CB CB is in intermediate position Check the position of CB, move CB to the test or to the service position (see chapters , ). Blinking LED indicator Failure After manual trip RESET was not performed Possibly electrical interlocks are engaged Press OPEN button See auxiliary wiring diagram or proceed with interlock chapters of the current manual. 70

71 Medium-Voltage Switchgear MILE MP12, MP17 and MP CM/TEL Malfunction detection Code of the Failure LED indication Type of malfunction 1 Power outage exceeds 1,5 s ± 0,5 s or applied voltage exceeds prescribed limit 2 Nonconformit of auxiliary contact of ISM 3 Actuator-coil is open-circuited 4 Actuator-coil is short circuited 5 Manual trip >=6 Nonconfirmity of Module In case the malfunction has not been determined and failure cannot be eliminated, please contact your nearest TEL office Opening of the cable and circuit breaker compartment doors in emergency cases. Interlock overcoming. Two openings are placed on side of the cable and circuit breaker door. Put M6 hex key into opening and unscrew two bolt witch hold interlocked hook. When hook is released door can be opened. 71

72 TECHNICAL MANUAL AND APPLICATION GUIDE LIST OF CHANGES Medium-Voltage Switchgear MILE MP12, MP17.5 and MP24 Tavrida Electric Export rev.03 released Nr. Page number Date Author Comments 1 all pages A. Hromov All Pages, release of ver.3 72

73 Medium-Voltage Switchgear MILE MP12, MP17 and MP24 NOTES 73

74 Engineering Your Power AS Tavrida Electric Export Tallinn Office 14, Visase str Tallinn Estonia Tel: Fax: ROMANIA Moscow Office 3rd floor, 1A, Grizodubovoy str., Moscow Russia Tel./Fax: +7 (499) POLAND Vilnius Office 222 Ukmerges str Vilnius Lithuania Mobile: Fax: UZBEKISTAN Cairo Office 25 Tayran Street (Mahmoud Shaltout), Nast City, Cairo, Egypt Tel.: Fax: Web: Your regional office Energobit TAVRIDA Tavrida Electric Polska sp. z o.o. Str. Luncii nr. 5A ul. Towarowa 23a Cod Cluj-Napoca, Romania TYCHY Tel: Tel.:+48 (32) , Fax: (32) , dan.tatar@energobit.com +48 (32) Web: Faks:+48 (32) telp@tavrida.pl Web: TAVRIDA ELECTRIC Uzbekistan Navoi Str. 9, Tashkent Uzbekistan Tel./Fax: info@tavrida.uz Web: This document is copyright and is intended for users and distributors of Tavrida Electric products. It contains information that is the intellectual property of Tavrida Electric and this document, or any part thereof, should not be copied or reproduced in any form without the prior permission of Tavrida Electric Tavrida Electric applies a policy of ongoing development and reserves the right to change products without notice. Tavrida Electric does not accept any responsibility for loss or damage incurred as a result of acting or refraining from action based on information in this Catalogue.

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A. SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation 630 3150A SYSclad 12 17,5kV 16 31,5kA Generalities SYSclad is a medium voltage switchboard metal clad

More information

UniGear. Technical Guide

UniGear. Technical Guide UniGear Technical Guide CONTENTS 0 CONTENTS 1.1 Compartments 1/2 1.2 Components of the structure 1/3 1.2.1 Hot-galvanized steel sheet 1/3 1.2.2 Painted steel sheet 1/4 1.2.3 Copper 1/5 1.2.4 Insulating

More information

Air-insulated switchgear UniGear type ZS1

Air-insulated switchgear UniGear type ZS1 Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 1-7074 D 12-03-2003 - Air-insulated switchgear UniGear type ZS1 ABB Power Technologies / 2-7075 D 1 2-03-2003 - Rated voltage kv 12 17.5

More information

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE

AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE AIR INSULATED EXTENDABLE SWITCHGEAR UP TO 12KV GUIDE Certificate Number FM35831 APPLICATION Typical Uses and Classification The MSGair switchgear is used in transformer and switching substations mainly

More information

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work GE Consumer & Industrial Power Protection New SecoGear 12-24kV GE imagination at work General SecoGear metal-clad switchgear is designed and manufactured with advance technology and has been comprehensively

More information

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel

EMC 24 SERIES METAL CLAD SWITCHGEAR. We engineer, we assure. Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel We engineer, we assure. EMC 24 SERIES METAL CLAD SWITCHGEAR Up to 24 kv - 25 ka With Withdrawable, Air-Insulated, Medium Voltage Distribution Panel Saudi Cable Company REF: EMC24-EN-16-04 2 www.elimsan.com

More information

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV CE - B36 - C - en - REV.00 2011.9 EDIU VOLTAGE EDIU VOLTAGE APPLICATION CE-B etal Clad switchboards are designed for use in public and industrial distribution system up to 36kV for the operation and protection

More information

the safe, reliable, and efficient choice for MV switchgear

the safe, reliable, and efficient choice for MV switchgear Power Xpert UX IEC Medium Voltage switchgear Tested to IEC 62271-200 17.5 kv up to 50 ka - 3 s 24 k V up to 25 ka - 3 s Air insulated switchgear Internal arc classified LSC2B-PM UX the safe, reliable,

More information

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear Circuit-Breaker www.siemens.com/energy Switchgear Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear s Technology Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated

More information

NXPLUS C Single busbar. Maintenance-free for lifetime

NXPLUS C Single busbar. Maintenance-free for lifetime NXPLUS C Single busbar Maintenance-free for lifetime Energy Distribution Welcome! Page 2 Content Overview Technical data Typicals Panel design Circuit-Breaker panel Busbar Operation Metering Low-voltage

More information

with Vacuum Circuit Breaker HAF

with Vacuum Circuit Breaker HAF M E T A L - C L A D S W I T C H G E A R Safety and Reliability with Vacuum Circuit Breaker HAF Flexible Design and Compact with Vacuum Circuit Breaker HVF Easy Installation and Maintenance We build a better

More information

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV MEDIUM VOLTAGE MEDIUM VOLTAGE APPLICATION CE-B Metal Clad switchboards are designed for use in public and industrial distribution system up to 24kV for the operation and protection of lines, generators,

More information

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy Our brand A strong brand for strong products: The ENERGOLINE brand represents our product portfolio of INDUSTRIAL SWITCHGEAR SYSTEMS. Our products are characterized by a high degree of safety, flexibility

More information

CPG.0 Single busbar gas-insulated cubicles

CPG.0 Single busbar gas-insulated cubicles MV Switchgear Primary Distribution CPG.0 Single busbar gas-insulated cubicles Up to 36 kv CPG System The quality of products designed, manufactured and installed by Ormazabal is underpinned by the implementation

More information

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV CE--C-en-REV.04 2016.1 MEDIUM VOLTAGE MEDIUM VOLTAGE APPLICATION CE- Metal Clad switchboards family are designed for use in public and industrial distribution system up to 40,5kV for the operation and

More information

Metal Clad Air Insulated Switchgear

Metal Clad Air Insulated Switchgear Metal Clad Air Insulated Switchgear 1/ SecoGear Metal Clad Switchgear Features Fully metal-clad Equipped with Embedded pole VCB Full Front access (can be installed against wall) Perfect interlocking system

More information

PIX-H Metal-clad switchgear up to 17.5kV

PIX-H Metal-clad switchgear up to 17.5kV AIR INSULATED SWITCHGEAR PIX-H Metal-clad switchgear up to 17.5kV for high rated applications Technical Specifications AREVA T&D Summary - Technical description... 3 - Standards... 6 - PIX in detail...

More information

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS

OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS OVERVIEW DESCRIPTION AND CHARACTERISTICS APPARATUS AND TYPES AVAILABLE SWITCHGEAR CHARACTERISTICS INSTRUMENT TRANSFORMERS MEASUREMENT SENSORS PROTECTION AGAINST INTERNAL ARCS TYPICAL UNITS 3 Characteristics

More information

Benefits, typical uses

Benefits, typical uses R-HA26-013. eps Switchgear Type 8BT1, up to 24kV,Air-Insulated Contents Application Page Application Benefits 2 Typical uses 2 and 3 Technical Data Ratings 4 Classification, dimensions, 5 room planning

More information

Unified requirements for systems with voltages above 1 kv up to 15 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv (1991) (Rev.1 May 2001) (Rev.2 July 2003) (Rev.3 Feb 2015) (Corr.1 June 2018) Unified requirements for systems with voltages above 1 kv up to 15 kv 1. General 1.1 Field of application The following requirements

More information

Switchgear Type 8BT1, up to 24 kv, air-insulated. Medium Voltage Switchgear Catalog HA 26.

Switchgear Type 8BT1, up to 24 kv, air-insulated.   Medium Voltage Switchgear Catalog HA 26. www.siemens.com/medium-voltage-switchgear Switchgear Type 8BT1, up to 24 kv, air-insulated Medium Voltage Switchgear Catalog HA 26.31 2012 Answers for infrastructure and cities. R-HA26-013. eps Contents

More information

UniSafe 36. Medium voltage, arc-proof, air-insulated, metal-clad switchboard

UniSafe 36. Medium voltage, arc-proof, air-insulated, metal-clad switchboard UniSafe 36 Medium voltage, arc-proof, air-insulated, metal-clad switchboard CHARACTERISTICS AND APPLICATIONS DESCRIPTION APPARATUS SWITCHBOARD CHARACTERISTICS REF 542 PLUS UNIT INSTRUMENT TRANSFORMERS

More information

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application The most advanced Arc-Resistant Switchgear, designed and built to provide maximum safety in the event of an Internal Arcing Fault. 5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application Page 1

More information

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear.

Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear. Circuit-Breaker Switchgear Type SIMOPRIME, up to 17.5 kv, Air-Insulated Medium-Voltage Switchgear www.siemens.com/energy Technology s Contents Application Page Benefits 2 Typical uses 2 and 3 Technical

More information

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance

Safe and Reliable. Flexible, Compact Design. Easy Installation and Maintenance M E T A L - C L A D S W I T C H G E A R Safe and Reliable Flexible, Compact Design Easy Installation and Maintenance We build a better future! Hyundai HMS medium-voltage metal-clad switchgears and control-gears,

More information

33KV INDOOR SWITCHGEAR

33KV INDOOR SWITCHGEAR 33KV INDOOR SWITCHGEAR September 2017 Engineering Department WEST BENGAL STATE ELECTRICITY TRANSMISSION COMPANY LIMITED Regd. Office: VidyutBhawan, Block DJ, Sector-II, Bidhannagar, Kolkata 700091. CIN:

More information

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected. Issued: January 2013 Copyright by ZPUE Katowice S.A. All rights reserved. Neither this catalogue nor any part of it may be copied using any method or for any purposes. Most studies are legally protected.

More information

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment General The switchgear must be suitable for 36 kv rated voltage and specifically conceived for the secondary distribution substations in M.V. with either ring or radial type networks. The switchgear must

More information

Gas Insulated Metal-clad Switchgear, HMGS!

Gas Insulated Metal-clad Switchgear, HMGS! Medium Voltage HMGS-G10 HYUNDAI Medium Voltage Gas Insulated Metal-clad Switchgear, HMGS! SF6 Gas Insulated Metal-clad Switchgear is an integrated assembly of vacuum circuit breaker, 3-position switch,

More information

ZX2 Gas-insulated medium voltage switchgear

ZX2 Gas-insulated medium voltage switchgear Gas-insulated medium voltage switchgear Double busbar 13 8 10 12 11 10 9 8 7 2 1 3 4 5 6 2 Versatile Partitioned single or double busbar system for all applications even with the most demanding parameters

More information

Vacuum Circuit Breaker

Vacuum Circuit Breaker Vacuum Circuit Breaker 12/24kV VECTOR series Vacuum Circuit Breaker VMS series Metal-clad Switchgear Medium Voltage Systems 003 FM 73638 12/24kV VECTOR VCB Features of the VECTOR Vacuum Circuit Breaker:

More information

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment)

TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment) TECHNICAL SPECIFICATION OF 11KV SF6 / VCB METAL ENCLOSED, INDOOR (PANEL TYPE) / OUTDOOR RING MAIN UNIT (RMU). (IEC standard equipment) 1 SCOPE OF SUPPLY This specification covers design, manufacture, shop

More information

Power Xpert UX 36 High-voltage switchgear system. Reliable and safe for high performance applications

Power Xpert UX 36 High-voltage switchgear system. Reliable and safe for high performance applications Power Xpert UX 36 High-voltage switchgear system Reliable and safe for high performance applications A high-performance solution for high-voltage power distribution Eaton s Power Xpert UX 36 IEC high-voltage

More information

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards Medium Voltage Switchgear Primary Distribution CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka General description Presentation Ormazabal s CPG System includes the CPG.1

More information

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable www.siemens.com/medium-voltage-switchgear Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear Catalog HA 41.43 2012 Answers for infrastructure and cities. Neue Bilder

More information

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU

Medium Voltage Distribution PIX. Air Insulated Switchgear up to 24 kv PARS TABLEAU Medium Voltage Distribution PIX Air Insulated Switchgear up to kv PIX Air Insulated Switchgear up to kv The PIX system has been designed in accordance with international (IEC) standards, and gives an optimal

More information

Metal Clad Switchgears

Metal Clad Switchgears SNC Series Metal Clad Switchgears > up to 36 kv Rated Voltage > up to 2500 A Rated Current > up to 40 ka Rated Short Time Withstand Current > LSC-2B, PM, AFLR > In Confirmity with IEC 62271-1, 100, 102,

More information

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus DISTRIBUTION SOLUTIONS GSec Gas-insulated switching and isolating apparatus GSec is a three-position SF6 gas-insulated switchdisconnector designed for use in medium voltage switchgear for secondary distribution

More information

Air Insulated Switchgear NXAirS, 40.5kV Answers for infrastructure and cities.

Air Insulated Switchgear NXAirS, 40.5kV Answers for infrastructure and cities. www.siemens.com.cn/medium-voltage-switchgear Air Insulated Switchgear NXAirS, Answers for infrastructure and cities. Applications Page Application Type 2 Typical uses 3 Classification 3 Type NXAirS withdrawable

More information

ZX2.2 Gas-insulated medium voltage switchgear

ZX2.2 Gas-insulated medium voltage switchgear ZX2.2 Gas-insulated medium voltage switchgear 2 Brochure ZX2.2 Power engineering from ABB Solutions for the future As a technology group with global operations, ABB supplies the solutions of the future

More information

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv]

Voltage Rated operating voltage [kv] Rated power frequency withstand voltage [kv] Rated lightning impulse withstand voltage [kv] BasisBlock MC 1 Standards and Regulations IEC 62271-200 ; VDE 0671-200 ; BS EN 62271-200 Technical Data MC1-12 MC1-24 Voltage Rated operating voltage [kv] 12 24 Rated power frequency withstand voltage

More information

UniSafe 36 Product Presentation. ABB Elektrik Sanayi A.S. - Page 1

UniSafe 36 Product Presentation. ABB Elektrik Sanayi A.S. - Page 1 UniSafe 36 Product Presentation Elektrik Sanayi A.S. - Page 1 UniSafe 36 air insulated metal-clad internal arc proof Elektrik Sanayi A.S. - Page 2 for power distribution solutions Elektrik Sanayi A.S.

More information

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT SWITCHCRAFT Switchcraft Europe GmbH Switchgear Product Overview igis Gas Insulated Switchgear isis Solid Insulated Switchgear icb - Vacuum Circuit Breaker iair - Air insulated switchgear panel Switchcraft

More information

KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal. Enclosed Switch. 1.General. 2.Model Definition

KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal. Enclosed Switch. 1.General. 2.Model Definition KYN28-12(GZSI-12Z)Armoured Middle-Mounted Metal Enclosed Switch 1.General KYN28-12 armoured middle-mounted metal enclosed switchgear (hereinafter referred to as switchgear) is a new product with own design

More information

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS) SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS) About company The «Elektroapparat» plant starts its operation in 1922 as a plant manufacturing high-voltage electrical equipment. During the first two

More information

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN

e 2 ALPHA Medium Voltage Switchgear K Catalogue EN e 2 ALPHA Medium Voltage Switchgear K-1.2.3 Catalogue EN WE CREATE IDEAS WITH POWER! ELEKTROMETAL ENERGETYKA SA provides solutions for electrical power engineering. Our services are carried out by a team

More information

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS 2001.09 KYN28A-12 (GZS1) A.C Metalclad Removable Switchgear for Indoor Use --------The Leader in Switchgear Up to 12kV 1. The

More information

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura

GAE CLAD. Catalogue Metal - Clad Switchgear Up To 24 kv. Vacuum Circuit Breaker With Embedded Poles. PT Guna Era Manufaktura GAE CLAD \ METALCLAD SWITCHGEAR up to 24 kv \ M600204.15 PT Guna Era Manufaktura Catalogue 2015 GAE CLAD Vacuum Circuit Breaker With Embedded Poles Metal - Clad Switchgear Up To 24 kv General Description

More information

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear Totally Integrated Power SIMOSEC Catalog HA 41.43 Edition Sept. 2014 Answers for infrastructure and cities. Neue

More information

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

MV Air Insulated Switchgear TAP17. Technical Data TGOOD MV Air Insulated Switchgear TAP17 Technical Data TGOOD 2017.1 Operating environmental conditions Place of installation: Indoor or outdoor Ambient temperature: 25 ~ +40 (higher or lower temperature optional)

More information

8DJ. Maintenance-free for lifetime

8DJ. Maintenance-free for lifetime 8DJ Maintenance-free for lifetime Energy Distribution Welcome! Page 2 October 1 st 2008 8DJ Main Applications for Medium-Voltage Switchgear Power generation Power stations G Power transmission High and

More information

The vacuum circuit breaker for commercial buildings, industrial plants and utilities

The vacuum circuit breaker for commercial buildings, industrial plants and utilities The vacuum circuit breaker for commercial buildings, industrial plants and utilities EasyPact EXE The easy choice for more value 2 EasyPact EXE EasyPact EXE, a medium voltage vacuum circuit breaker optimizing

More information

medium voltage switchgear manufacturer VACUUM CIRCUIT-BREAKER SWITCHGEAR TYPE SIMOPRIME, UP TO 17.5kV, AIR INSULATED MEDIUM-VOLTAGE SWITCHGEAR. UNDER LICENSE BY SIEMENS. www.simosynergy.com/simoprime VACUUM

More information

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN

e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K Catalogue EN e 2 ALPHA -2S Medium Voltage Double Busbar Switchgear K-11.1.2 Catalogue EN We Create Ideas With Power! e 2 ALPHA-2S double busbar switchgear is designed for use in primary and secondary electric energy

More information

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position LET S BE PACIFIC November 0 Volume Number 5 ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position Federal Pacific has the capability to engineer, fabricate and assemble

More information

Unitole UP kv Primary substations Motor control centres

Unitole UP kv Primary substations Motor control centres Unitole UP 3.6-17.5 kv Primary substations Motor control centres Product Focus Air-insulated withdrawable switchgear with vacuum circuit-breakers and contactors Creating Solutions Eaton creates power-engineering

More information

ZX-Family Gas-insulated medium voltage switchgear

ZX-Family Gas-insulated medium voltage switchgear ZX-Family Gas-insulated medium voltage switchgear Minimum overall costs ZX offers maximum economy The compact design of the panels reduces the space required and therefore the size of the station. Freedom

More information

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc

GE Industrial Solutions. User/Installation Manual for 4.76kV -15kV SecoBloc GE Industrial Solutions User/Installation Manual for 4.76kV -15kV SecoBloc Index General Scope...3 Standards...3 Operating conditions...3 Technical specification...3 Basic structure Features...4 Operation...4

More information

USN. Metal-clad type switchgear. Technical information

USN. Metal-clad type switchgear. Technical information Metal-clad type switchgear USN 50 series Technical information ELGA UAB Pramonės str. LT-7850 Šiauliai, Lithuania Tel.: +70 4 59470 Fax: +70 4 59475 E-mail: info@elga.lt Internet: www.elga.lt USN-50-Tech.Inf.

More information

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment. General Unit substations shall be 500 kva minimum, 1500 kva maximum unless approved otherwise by the University. For the required configuration of University substations see Standard Electrical Detail

More information

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications ABB a global leader ABB is a global leader in power and automation technologies that enable utility and industry customers

More information

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec Catalog HA 41.43 Edition 2018 Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable Medium-Voltage Switchgear siemens.com/simosec Application Typical uses R-HA41-135.tif R-HA40-112.tif R-HA41-115.tif

More information

MESG 12 / 17.5 / 24 / 36 KV

MESG 12 / 17.5 / 24 / 36 KV MESG 12 / 17.5 / 24 / 36 KV Medium Voltage Air Insulated Metal Enclosed Switchgear up to 36 kv- up to 1250 A - up to 25 ka for 1 sec. with SF6 or vacuum circuit breakers. 750 METAL ENCLOSED 1 1 ) GENERAL

More information

UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES UP TO 17,5 kv LSC 2B PM (METAL-CLAD) WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES 1 TABLE OF CONTENTS 1. SCOPE 2. GENERAL 2.1 STANDARDS AND REGULATIONS 2.2 OPERATING CONDITIONS 2.3 DOCUMENTATION

More information

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications Medium voltage products UniSec Y800 New 24 kv air-insulated medium voltage switchgear to e-istribuzione specifications UniSec Y800 ubicles available Unit e-istribuzione specifications (Ed. 4) UniSec IS/1

More information

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure 2017 SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Brochure SafeGear Motor Control Center Arc resistant Metal-Clad construction Brochure Table of Contents 1. Description 1 1 2. SafeGear

More information

Unitole UP kv Primary substations Motor control centres

Unitole UP kv Primary substations Motor control centres Unitole UP 3.6-17.5 kv Primary substations Motor control centres Product Focus Air-insulated withdrawable switchgear with vacuum circuit-breakers and contactors Creating Solutions Eaton Holec creates power-engineering

More information

Metal Clad VCBs ~ Mk1

Metal Clad VCBs ~ Mk1 Metal Clad VCBs ~ Mk1 DUVI 150/40 ROLL ON FLOOR VCBs Range: 6kV, 00A, 1.5kA, 12kV, 150A, 40kA ( 4A000A Bus-Bars ) ` Widest range for MV (up to 6kV) Distribution Networks Megawin make metal clad VCB Panels

More information

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR ANGLER SWITCHING DEVICES CONTENTS 1. General 2. Switchgear Types - Switch Disconnector - Disconnector 3. Cubicle Types - Cubicle with Switch Disconnector

More information

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.0 008 Answers for energy. R-HG11-17.tif Siemens HG 11.0 008 Contents Contents Page SION Vacuum Circuit-Breakers Description General Construction

More information

MEDIUM VOLTAGE SWITCHGEAR. DW-2, Primary switchgear, air insulated and metal clad.

MEDIUM VOLTAGE SWITCHGEAR. DW-2, Primary switchgear, air insulated and metal clad. DW-2 MEDIUM VOLTAGE SWITCHGEAR BUILT TO LAST! DW-2, Primary switchgear, air insulated and metal clad. DW-2 s modular design allows you to create rational, economical & custom-made combinations of medium-voltage

More information

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear MEDIUM VOLTAGE PRODUCTS Powerbloc Pre-assembled modules for building medium voltage switchgear Powerbloc are the ideal solution for replacing fixed circuit breakers with withdrawable circuit breakers,

More information

UniSec Operation and maintenance manual

UniSec Operation and maintenance manual Medium voltage products UniSec Operation and maintenance manual Safety 3 For your safety! 3 Skilled personnel 3 Critical messages 3 Contact us! 3 1. Introduction 4 1.1 General aspects 4 1.2 Operation and

More information

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

SION Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG Medium-Voltage Equipment Selection and Ordering Data Catalog HG 11.02 2011 Answers for energy. R-HG11-172.tif 2 Siemens HG 11.02 2011 Contents SION Vacuum Circuit-Breakers Medium-Voltage Equipment Catalog

More information

Instruction for Installation and Operation

Instruction for Installation and Operation KYN79 (i-ax) Metalclad Removable AC Metal-Enclosed Switchgear Instruction for Installation and Operation K 15 24 SM 01 02 Tianshui Changcheng Switchgear Factory January, 2007 Warning: This instruction

More information

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls

11kV Compact Switchgear. tec - range. Minimum to Zero SF6 Insulation Gas. Outec Controls 11kV Compact Switchgear tec - range Minimum to Zero SF6 Insulation Gas. Outec Controls 1 tec xx - 11kV Switchgear Contents 1 tec CB - SF6 Free Switchgear... 3 1.1 Description:... 3 1.2 1.3 Features the

More information

PowerCube type PB series A complete solution for OEMs

PowerCube type PB series A complete solution for OEMs Preliminare july 2006 series A complete solution for OEMs IndustrialIT TM ABB PT Dalmine 1VCP000093 Rev.C, it Presentation 2004.07 QUALITY SYSTEM Certification ISO 9001-2000 ENVIRONMENTAL MANAGEMENT SYSTEM

More information

DISTRIBUTION SOLUTIONS. UniGear MCC Medium-voltage air-insulated motor control center

DISTRIBUTION SOLUTIONS. UniGear MCC Medium-voltage air-insulated motor control center DISTRIBUTION SOLUTIONS UniGear MCC Medium-voltage air-insulated motor control center UniGear MCC as an air-insulated medium-voltage motor control center is designed specifically for motor, transformer

More information

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED) PRODUCED BY THE OPERATIONS DIRECTORATE OF ENERGY NETWORKS ASSOCIATION Issue 3 2012 SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED) www.energynetworks.org 2012 Energy Networks

More information

Reliable medium-voltage switchgear for fail-safe operation, up to 24 kv siemens.com/simoprime-partner

Reliable medium-voltage switchgear for fail-safe operation, up to 24 kv siemens.com/simoprime-partner SIMOPRIME partnering Reliable medium-voltage switchgear for fail-safe operation, up to 24 kv siemens.com/simoprime-partner SIMOPRIME partnering Typical applications SIMOPRIME technology partner: air insulated

More information

TECHNICAL SPECIFICATION. UP TO 36 kv METAL-CLAD. With WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES

TECHNICAL SPECIFICATION. UP TO 36 kv METAL-CLAD. With WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES TECHNICAL SPECIFICATION UP TO 36 kv METAL-CLAD With WITHDRAWABLE VACUUM CIRCUIT BREAKER MEDIUM VOLTAGE CUBICLES 1 TABLE OF CONTENTS 1. SCOPE 2. GENERAL 2.1 STANDARDS AND REGULATIONS 2.2 OPERATING CONDITIONS

More information

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1.

ZX1.5-R. Gas-insulated medium voltage for railway application DISTRIBUTION SOLUTIONS. Gas-insulated medium voltage for railway application ZX1. DISTRIBUTION SOLUTIONS ZX1.5-R Gas-insulated medium voltage for railway application Safety and reliability 20% footprint saving Easy operation Complete solution ZX1.5-R Gas-insulated medium voltage for

More information

Power IT Air Insulated Cubicle Uniswitch

Power IT Air Insulated Cubicle Uniswitch - 1-4/2/2003 Secondary Distribution Switchgear Power IT Air Insulated Cubicle Uniswitch Table of Contents Market segment Ratings New for 2003 Technical features Advantages Market segment Uniswitch Switchgear

More information

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear ATLV MaxSG Low Voltage Metal Enclosed Switchgear ABB, INC. Product General Description MaxSG Switchgear ABB MaxSG switchgear is a further continuation in the development of innovative products from ABB,

More information

B kv T&D GAS INSULATED SWITCHGEAR

B kv T&D GAS INSULATED SWITCHGEAR GAS INSULATED SWITCHGEAR B 105 170 300 kv The increasing demand for electrical power in cities and industrial centers necessitates the installation of a compact and efficient distribution and transmission

More information

ABB AG - EPDS. Ultra-Fast Earthing Switch UFES active internal arc protection

ABB AG - EPDS. Ultra-Fast Earthing Switch UFES active internal arc protection ABB AG - EPDS Ultra-Fast Earthing Switch UFES active internal arc protection Agenda Arc fault Protection concepts Ultra-Fast Earthing Switch type UFES Principle Components Differentiation of protection

More information

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36

10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36 10/2015 CUBICLE AND METAL-CLAD MEDIUM VOLTAGE SWITCHGEARS WEGA 07 WEGA 12 WEGA 17 WEGA 24 WEGA 36 Gdańsk, October 2015 Improving the competitiveness of the company ELMOR through investments introducing

More information

PIX High. Medium-voltage switchgear. Air-insulated switchgear kv ( 50 ka) Assembly - Operation - Maintenance Technical Manual

PIX High. Medium-voltage switchgear. Air-insulated switchgear kv ( 50 ka) Assembly - Operation - Maintenance Technical Manual Medium-voltage switchgear PIX High Air-insulated switchgear 7.5 kv ( 50 ka) Assembly - Operation - Maintenance Technical Manual No. AGS 53 50-0 Edition /04 www.schneider-electric.com Manufacturer: Schneider

More information

with Vacuum Circuit Breaker HAF

with Vacuum Circuit Breaker HAF M E T A L - C L A D S W I T C H G E A R Safety and Reliability with Vacuum Circuit Breaker HAF Flexible Design and Compact with Vacuum Circuit Breaker HVF Easy Installation and Maintenance We build a better

More information

B kv Gas-insulated Substations

B kv Gas-insulated Substations 72.5 145 kv Gas-insulated Substations The increasing demand for electrical power in cities and industrial centres requires the installation of a compact and efficient distribution and transmission network.

More information

Vacuum Circuit Breaker VS1

Vacuum Circuit Breaker VS1 Vacuum Circuit Breaker VS1 Product features Conform to GB, IEC, DL and JB standards KEMA type test Level A certificate Ideal contact material and shape, ensuring low current carrying value and stable contact

More information

Power Systems PU. HYOSUNG Standard High-voltage Switchgear ProSWGR. Medium Voltage Metal-clad Switchgear

Power Systems PU. HYOSUNG Standard High-voltage Switchgear ProSWGR. Medium Voltage Metal-clad Switchgear Power Systems PU HYOSUNG Standard High-voltage Switchgear ProSWGR Medium Voltage Metal-clad Switchgear Power & Industrial Systems Performance Group Hyosung Power Systems has been continuously enhancing

More information

DIRECT CONTACT. Switchgear Sales Team TEL : ~9 CHANGWON PLANT Switchgear Design Team TEL : ~9

DIRECT CONTACT. Switchgear Sales Team TEL : ~9 CHANGWON PLANT Switchgear Design Team TEL : ~9 HEAD OFFICE 450, Gongdeok-Dong, Mapo-Gu, Seoul, Korea 121-720 TEL : 82-2-707-7000 R&D CENTER 183, Hogye-Dong, Dongan-Gu, Anyang-Shi, Gyeonggi-Do, Korea 431-080 TEL : 82-31-428-1000 CHANGWON PLANT 454-2,

More information

CONTENT. EPE METALCLAD SWITCHGEARS AMS SERIES 12kV AMS METALCLAD SWITCHGEAR 24kV AMS METALCLAD SWITCHGEAR 40.5KV AMS METALCLAD SWITCHGEAR

CONTENT. EPE METALCLAD SWITCHGEARS AMS SERIES 12kV AMS METALCLAD SWITCHGEAR 24kV AMS METALCLAD SWITCHGEAR 40.5KV AMS METALCLAD SWITCHGEAR CONTENT EPE METLCLD SWITCHGERS SERIES EPE 1220 / - 12KV METLCLD SWITCHGER EPE 10D - 12KV METLCLD SWITCHGER EPE 24-24KV METLCLD SWITCHGER EPE 36-36KV METLCLD SWITCHGER EPE METLCLD SWITCHGERS MS SERIES 12

More information

Ultra Fast Earthing Switch UFES retrofit Overview

Ultra Fast Earthing Switch UFES retrofit Overview Gordon van der Linde ABB PTMV - Service Ultra Fast Earthing Switch UFES retrofit Overview May 20, 2013 UFES Slide 1 Ultra Fast Earthing Switch UFES retrofit Content 1. Effects of an internal arc 2. The

More information

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS A. 11 KV SWITCHGEAR 1.0 SWITCHGEAR ASSEMBLY 1.1 Make : 1.2 Type : 1.3 Reference Standard : 1.4 Voltage (Nom./Max.) KV : 1.5 Phase, Frequency No,Hz.

More information

AF series contactors (9 2650)

AF series contactors (9 2650) R E32527 R E39322 contactors General purpose and motor applications AF series contactors (9 2650) 3- & 4-pole contactors General purpose up to 2700 A Motor applications up to 50 hp, 900 kw NEMA Sizes 00

More information

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A)

24kV Medium Voltage Switchgear Metal-Enclosed (LSC2A) M6 24kV Medium Voltage Switchgear MetalEnclosed (LSC2A) GENERAL FEATURES GENERAL DESCRIPTION The structure of the cubicles, of considerable strength, has selfsupporting structure and is made of steel sheet

More information

Product Specification

Product Specification KYN28-12 Series H.V Metal Clad Switchgear Product Specification 10/08/2015 Electrical Treasure One-Stop Supplier Of Electrical Equipment 1 KYN28-12 Series With Prevent Wrong Operation Of Metal Clad Switchgear

More information

Modular medium-voltage switchgear. NorMax

Modular medium-voltage switchgear. NorMax Modular medium-voltage switchgear NorMax NorMax MODULAR MEDIUM-VOLTAGE SWITCHGEAR 2 NorMax Modular medium-voltage switchgear Contents Subject Page Table of contents 2 Introduction and main features 2 Technical

More information