AUTOMATIC FILTER & STRAINER SELECTION PG. 3 FI SERIES SINGLE BAG FILTER HOUSINGS PG. 4 FI MULTI BAG FILTER HOUSINGS PG. 6
|
|
- Oswin Roy Sparks
- 6 years ago
- Views:
Transcription
1
2 TABLE OF CONTENTS AUTOMATIC FILTER & STRAINER SELECTION AUTOMATIC FILTER & STRAINER SELECTION PG. 3 FI SERIES SINGLE BAG FILTER HOUSINGS PG. 4 FI MULTI BAG FILTER HOUSINGS PG. 6 MODEL CS SIMPLEX STRAINERS VESSELS PG. 8 All units available in Carbon Steel, Stainless and Alloys. Dimensions are general, all information to be confirmed with design drawing. MODEL CD DUPLEX STRAINER VESSELS PG. MODEL ACM SELF-CLEANING AUTOMATIC STRAINER 4 18 PG. 12 MODEL ACS AUTOMATIC STRAINER PG. 14 AUTOMATIC FILTER MODEL FAFI & FAFX PG. 20 STRAINER SELECTION CHART Degree of Filtration Pipeline Pressure Limits Pipeline Temperature Limits Pressure Temperature Vibration and Shock Corrosion Screen Opening Size Strainer Rating Material of Construction Flow May Be Interrupted Manual Basket Cleaning Simplex Flow May Not Be Interrupted Manual Basket Cleaning Duplex Type of Strainer Flow May Not Be Interrupted Automatic Basket Cleaning Self- Cleaning Pipeline Size Allowable Pressure Drop Size of Strainer 2 RAM LIQUID FILTRATION PRODUCT CATALOGUE 3
3 FI SERIES SINGLE BAG FILTER HOUSINGS FI MULTI BAG FILTER HOUSINGS RAM filter bag vessels are designed for industrial service. Single bag units are ideal for batch service or when flow interruption is possible. Four standard sized vessels handle various rates of flow and service. Industry standard filter bag sizes of LFB1, LFB2, P1S and P2S are used and also available from RAM Liquid Filtration. Consult the filter model table to determine applicable housing size based on flow rate. The RAM duplex model FI-400 is suitable for a maximum flow rate of 360 GPM, above this see multi-filter housings. With any of RAM s single bag unit designs, manifolds can be added to accommodate two or more housings. Manifolding of two or more units allows for continuous flow while one of the bag chambers is taken off line for filter change out. All vessels are equipped with quick opening covers to facilitate quick and seamless bag change out. Housings come standard with # wire mesh basket to support the filter bag. Housings are designed to produce a low pressure drop and provide the greatest efficiency and life of filter bags. SPECIFICATIONS: Quick opening hinged cover with handle Carbon steel, 304L/316L stainless steel All closure hardware Vent and gauge connections Legs or mounting bracket EPDM or BUNA N seals OPTIONS: Displacement float Alternate material of construction Magnetic post inserts Viton or teflon seals Polished finish for clean service Multi bag housings provide the optimal solution for high flow rates or heavier solid load. Each multi bag housing contains a series of # wire mesh baskets to support individual filter bags. The wire mesh basket offers tremendous integrity while providing the highest open area keeping pressure loss to a minimum. Typical applications include cooling water, plant effluents and many high volume liquid products. Not limited with filter area the multi bag housing is ideal for both heavy solid load applications and higher viscosity liquids. SPECIFICATIONS: Quick opening cover with lifting davit Carbon steel, 304L/316L stainless steel All closure hardware Vent and gauge connections Legs or mounting saddle EPDM or BUNA N seals OPTIONS: Displacement floats Alternate material of construction Magnetic post inserts Viton or teflon seals Wedge-wire baskets FILTER MATERIAL COMPATIBILITY For recommendations on which bag or filter housing material to use, contact RAM Liquid Filtration. FLOW RATE PRESSURE DROP DATA For complete technical data or pressure drop and how to size RAM Bag Filters, contact RAM Liquid Filtration. Information for sales reference only is subject to change without notice. 4 RAM LIQUID FILTRATION PRODUCT CATALOGUE 5
4 FI MULTI BAG FILTER HOUSINGS FI MUTLI BAG DRAWINGS FLOW RATE FOR NO. 1 SIZE FILTER BAGS AT A GIVEN VISCOSITY AT 1.0 PSI P TO USE THE CHART 1. Select micron rated bags at bottom of chart. 2. Follow the vertical line up until it intersects with the selected viscosity in centipoise. 3. Cross at right angles to left hand ordinate, which will indicate the flow rate at 1 psi pressure drop. 4. When centipoise lines run off at 80 gpm, DP is less than 1 psi pressure drop. NOTE: (A) For flow rates higher than chart - divide desired flow by flow given in chart to obtain resultant DP. (B) For #2 size bags - multiply results by 2. (C) For LFB-1 size bags - divide results by 4. (D) For LFB-2 size bags - divide results by 2. CONVERSION FORMULA Viscosity Units x Factor* x Specific Gravity / 5.62 = Absolute Viscosity (centipoises) VISCOSITY 70 F FACTOR Saybolt Furol.0 Redwood Standard Redwood Admiralty.87 Engler 34.5 Parlin Cup # Parlin Cup # Ford Cup # MacMichael 1.92 Demmler # Demmler # 14.6 Stormer (approx.) 13 Staybolt Seconds Universal 1.0 *The Conversion Formula is approximately valid when the numerator is greater than 250. For other values, consult Chemical Handbook. Flow Rate (gpm/bag/1.0 P.S.I.) PSI P Bag Micron Rating 0 Values in the graph are used as a reference only FILTER MATERIAL COMPATIBILITY For recommendations on which bag or filter housing material to use contact us at: or info@ramliquidfiltration.com GA1 FLOW RATE PRESSURE DROP DATA Contact us for complete technical data or pressure drop and how to size RAM bag filters. Information for sales reference only is subject to change without notice. Model # of Bag Size Inlet / Recommended Dimensional A B C D E F G&H I J Filter Model # of Bag Code Size Outlet Inlet Size / Recommended Max Flow Rate Dimensional Drawing A B C D E F G&H I J Filter Bags Code Outlet Size Max Flow Rate Drawing FI- 25 Bags 1 LFB- 1 1" 25 GA 1 1/2" 3/4" 5 1/2" 6 1/4" 4 1/2" * * * * FI- 25 FI LFB- 1 LFB " 1/2" GA 1 1/2" 16 3/4" 1/2" 511" 1/2" 67 1/4" 1/2" 4 1/2" * * * * FI- 0 FI LFB- 2 P1S 1 1/2" GA /2" 7/8" 1627" 1/2" 1611" 3/4" 713" 1/2" 48 1/2" 5/8" * * * * FI- 0 FI P1S P2S 2" 2" or 3" GA /8" 3927" 1/2" /4" 13" 8 5/8" * * * * FI- 200 FI P2S 2" 4" or 3" GA /8" 39 1/2" 29 3/4" 13" 8 5/8" * * * * FI- 400 FI P2S To 4" Spec GA " 7/8" " 1/2" 2919" 3/4" 13" 21" 87.5" 5/8" 26" * 3:06 * 2" * 16.5" * FI- 600 FI P2S To Spec GA 12 69" 51.5" 19" 21" 7.5" 8" 26" 3:06 4:08 2" 16.5" FI- 00 FI P2S To Spec GA 2 69" 51.5" 19" 21" 8" 26" 4:08 2" 16.5" FI- 00 FI P2S To Spec GA 2 69" 70" 51.5" 52" 19" 20" 21.5" 21" 8" 26" 4:08 6:08 2" 16.5" 18" FI FI P2S To Spec GA 2 70" 71" 52.5" 52" 20" 21" 21.5" 22" 8" 26" 28" 6:08 2" 18" 20" FI FI P2S To Spec GA 2 71" 73" 52.5" 53.5" 22.5" 21" 22" 23" 9.5" 8" 28" 30" 6:08 8: 2" 20" 22" FI FI P2S To Spec GA 2 73" 75" 53.5" 54.5" 22.5" 24.5" 23" 24" 9.5" 30" 32" 8: 2" 23.5" 22" FI FI P2S To Spec GA 2 75" 54.5" 24.5" 24" 9.5" 32" 34" 8: 2" 23.5" 25" FI FI P2S To Spec GA 2 75" 77" 54.5" 55" 24.5" 27.5" 24.5" 24" 9.5" 34" 38" 8: 2" 25.5" 25" FI FI P2S To Spec GA 2 77" 55" 27.5" 24.5" 9.5" 38" 40" 8: 2" 25.5" 27" FI FI P2S To Spec GA 2 77" 83" 60.5" 55" 27.5" 28" 24.5" 27.5" 9.5" 11" 40" 42" 8: 2" 27" FI FI P2S To Spec GA 2 83" 60.5" 28" 27.5" 11" 12" 42" 44" 8: 2" 29.75" 27" FI FI P2S To Spec GA 2 83" 85" 60.5" 61" 28" 27.5" 28" 12" 44" :12 8: 2" 29.75" FI FI P2S To Spec GA 2 85" 61" 28" 28" 12" 44" 46" :12 2" 29.75" 31.25" FI FI P2S To Spec GA 2 85" 61" 28" 28" 12" 46" :12 2" 31.25" FI FI P2S To Spec GA 2 85" 61" 28" 28" 12" 46" :12 2" 31.25" FI FI P2S To Spec GA 2 85" 61" 28" 28" 12" 46" :12 2" 31.25" FI FI P2S To Spec GA 2 85" 61" 28" 28" 12" 13" 46" 48" :12 2" 31.25" FI FI P2S To Spec GA 2 85" 87" 61" 62" 28" 29" 28" 29" 13" 48" :12 :14 2" 31.25" FI FI P2S To Spec GA 2 87" 88" 62.5" 62" 29.5" 29" 29.5" 29" 13" 48" 50" :14 2" 31.25" 34" FI FI P2S To Spec GA 2 88" 62.5" 29.5" 29.5" 13" 50" :14 2" 34" FI FI P2S To Spec GA 2 88" 89" 62.5" 29.5" 29.5" 13" 50" 52" :14 2" 35.5" 34" FI FI P2S To Spec GA 2 89" 92" 62.5" 64" 29.5" 36" 29.5" 32" 13" 52" 54" :14 2" 35.5" 36" FI P2S To Spec 4000 GA 2 92" 64" 36" 32" 13" 54" :14 2" 36" GA2 Dimensions are general, all information to be confirmed with design drawing. 6 RAM LIQUID FILTRATION PRODUCT CATALOGUE 7
5 MODEL CS SIMPLEX STRAINER VESSELS MODEL CS SIMPLEX STRAINER VESSELS RAM Liquid Filtration model CS is a fabricated single element strainer vessel. Inlet and outlet connections are on the same plane allowing for in-line pipe installation. Designed to be taken offline for basket clean out the CS is ideal for batch operations. The CS can handle high solid loads and higher viscosity liquids than smaller tee style strainers. The CS is offered in both bolted cover and quick opening designs. At the heart of the CS is a wedge wire straining element. This basket material has the highest open area percentage which allows for improved straining efficiency and longer run times between basket clean outs. SPECIFICATIONS: Inlet and outlet are standard ANSI 150# Carbon steel, 304L/316L stainless steel are standards Legs and/or support saddle OPTIONS: Open bottom basket for manual blow down of basket Off set connections with flat top basket flange Cover lifting davit Special alloy construction High pressure / temperature design Jacketing or heat tracing Special coating and lining available Clearance for Basket Removal G C A Dia Dia D F E H NPT B PRESSURE DROP CURVES Pressure Drop P.S.I CORRECTION FACTORS (BASKET SLOT OPENINGS) (Water) (smaller than ). Multiply the pressure drop from the chart by the following factors: Values in the graph are used as a reference only Flow Rate (Water) G.P.M. (0.032" Slot Opening and Larger) VISCOSITY CORRECTION FACTORS 1. Multiply the pressure drop for water by the specific gravity of liquid. 2. Multiply the result by the correction factor for the more viscous liquid. Water has a viscosity of 30 SSU. Dimensions are general, all information to be confirmed with design drawing. 8 RAM LIQUID FILTRATION PRODUCT CATALOGUE 9
6 MODEL CD DUPLEX STRAINER VESSELS MODEL CD DUPLEX STRAINER VESSELS Model CD is a duplexed arrangement of two individual straining chambers. A valve assembly allows either of the chambers to be isolated for cleaning while the opposite chamber maintains system flow. At the heart of the CD strainer are two wedge wire straining elements. This basket material has the highest open area percentage which allows for improved straining efficiency. STANDARD MATERIALS BODY: Carbon Steel or Stainless Steel BASKET: 304 Stainless Steel VALVES: Butterfly with ductile iron body ductile iron and stainless steel disc A C E B F D SPECIFICATIONS: Inlet and outlet are standard ANSI 150# Standard carbon steel, 304L/316L stainless steel Legs and/or support saddle OPTIONS: Open bottom basket for manual blow down of basket Off set connections with flat top basket flange Cover lifting davit Special alloy construction High pressure / temperature design Jacketing or heat tracing Special coatings and lining are available CORRECTION FACTORS (BASKET SLOT OPENINGS) (Water) (smaller than ). Multiply the pressure drop from the chart by the following factors: VISCOSITY CORRECTION FACTORS 1. Multiply the pressure drop for water by the specific gravity of liquid. 2. Multiply the result by the correction factor for the more viscous liquid. G 5 Pressure Drop Curves for CS PRESSURE DROP CURVES DIMENSIONAL CHART (APPROX. IN INCHES) Pressure Drop P.S.I Flow Rate (Water) G.P.M. (0.032" Slot Opening and Larger) Values in the graph are used as a reference only. Values in the graph are used as a reference only Dimensions are general, all information to be confirmed with design drawing. RAM LIQUID FILTRATION PRODUCT CATALOGUE 11
7 MODEL ACM SELF-CLEANING AUTOMATIC STRAINER MODEL ACM SELF-CLEANING AUTOMATIC STRAINER The model ACM self-cleaning strainer provides a highly efficient and reliable means of removing solids from process fluids. A cluster of wedge-wire easy clean straining elements provides positive straining. The exclusive easy clean straining elements are designed with a unique V shape to promote free flow of the incoming liquid and to discourage wedging of any particles. Normal flow is from the inside to the outside of the straining elements and backwashing is accomplished by the reversal of the flow through the elements. The easy clean straining elements are arranged to accumulate debris on the inside. A rotating arm which is vented to the atmosphere isolates each easy clean element for cleaning. Cleaning is accomplished by taking advantage of the system pressure and the use of a small portion of the system flow. When an element is isolated, an effective backwashing action is created without disturbing total flow. Accumulated debris is flushed out of the easy clean element through the backwashing arm and into the drain. The model ACM self-cleaning strainer can be ordered with either continuous backwashing or with the addition of a variety of optional control packages for intermittent backwashing. The model ACM selfcleaning strainers are capable of handling flow rates up to 32,000 USGPM and straining as fine as or 25 micron. TYPICAL STRAINER SPECIFICATION Self cleaning strainer Process liquid fluid type Flow rate in GPM Allowable clean pressure drop Operating pressure and temperature Design pressure and temperature Strainer body material of construction Wedge wire element material of construction Slot opening in element/straining size Inlet and outlet connection type and size Electrical requirements (automatic only) STANDARD MATERIALS Standard construction is carbon steel internal epoxy coated and stainless steel, all grades. STANDARD FEATURES Low initial cost Intermittent or continuous backwashing C D E INLET B G F H OUTLET INSPECTION PORT J INLET Stainless steel backwash assembly guided by maintenance-free marine-type cutless bearings Easy clean reverse wound wedge-wire Continuous flow during backwashing Low backwashing flow requirements TEFC Motor 1/220V, single phase, 50/60 Hz OPTIONS Other materials available, including monel and SMO 254 Eductor pump for low pressure service Horizontal configuration A BACKWASH ARM OUTLET DETAIL OF BACKWASH ARM FILTER ELEMENTS BACKWASH SHOE Pressure Drop Curves for ACM PRESSURE DROP CURVE L DIMENSIONS (APPROX. 150 PSI) K - DRAIN CONNECTION BACKWASH L M DIA. BACKWASH SHOE Pressure Drop P.S.I Flow Rate (Water) G.P.M. (1/32" Slot Opening) Values in the graph are used as a reference only. Dimensions are general, all information to be confirmed with design drawing. 12 RAM LIQUID FILTRATION PRODUCT CATALOGUE 13
8 MODEL ACM DESIGN, FEATURES & OPERATION MODEL ACM EASY CLEAN ELEMENTS Model ACM is offered for either horizontal or vertical installation and is available to strain as fine as degree of cleaning using RAM s own easy clean elements. The ACM has a larger screen area, providing more filtering surface than any other same size automatic strainer in the marketplace, equating a higher filter open area to inlet area ratio; this allows longer straining cycles and less backwash disposal and electrical usage. The ACM strainer is a fabricated, single body vessel with multiple straining elements. It was designed as a fully automatic self-cleaning strainer. The vessel is available fabricated to ASME Code latest edition and addenda ( U stamped) and National Board Registered, or built in general accordance to ASME Code without code stamp or registration. In Canada, it is available also with CRN registration as required by provincial codes. Inlet and outlet connections are on the sides. The debris laden fluid enters the large lower chamber where it slows down and heavier contaminants settle to the bottom. The fluid flows upward into the straining elements. The fluid then passes through the screen media and exits the strainer through the outlet nozzle. Contaminants gather on the inside of the straining elements. The ACM strainer can perform self-cleaning (backwashing) without interruption of flow. These strainers are designed for liquid service where large quantities of debris must be removed. The ACM strainer uses a motor driven backwash arm to clean the straining elements. The strainer is backwashed by starting the backwash drive and opening the backwash drain valve. This backwashing reverses the flow through each straining element sequentially. The backwash assembly is rotated to cover one element hole in the tube sheet opening a flow path to the outside via the backwash drain. The strainer utilizes system pressure and a percentage of system flow to backwash the straining elements. The controls to accomplish this can be as simple as a toggle switch to start and stop the backwash drive motor and a manual gate or ball valve to control the system backwash flow. The ACM straining element is a cylindrical, reverse wound and resistance welded wedge-wire tube easy clean that is closed at one end and open at the other. Flow during straining is from the inside to the outside of this straining element. Flow direction for backwashing, however, is opposite. The straining elements are constructed for easy replacement. They are held in place with hold down rings or plates, bolted to hold down rods. The backwash arms provide a flow path for the debris collected and the fluid to dislodge the debris during the backwash cycle. The backwash arm directs the dirty fluid to a drain or alternate collection device at atmospheric pressure outside of the strainer. The arm is slowly rotated to allow each straining element to be backwashed during a revolution. Each straining element is isolated by a backwash shoe. The backwash drive system converts the high rotational speed motion of the electric motor to a low rotational speed so as to more effectively backwash the straining element. A shear pin protects the gear reducer, shafting and backwash arm. The backwash system consists of the backwash arms, the backwash shoes and piping that allows the backwash fluid to exit the strainer to an open or low pressure dirty outlet connection. RAM wedge-wire screens are designed to give maximum open area and deliver top performance in any screening application. Every step of production from raw material, wire shaping, screen winding to finished product is done under the same roof, ensuring the quality of the most vital part of any liquid or solid separation strainer filter element. The easy clean straining elements manufactured by RAM are available in reverse wrapped configuration from (25 micron) to (12,500 micron). RAM easy clean straining elements are designed to give maximum open area and to deliver top performance in any straining or filtering application. Easy clean elements discourage wedging of particles by helical wrapping of vertical rods with a V shaped profile wire. All internal vertical rods are welded to the surface wire at every intersection. The vertical rods being rigidly welded give a smooth unobstructed surface and do not impede the free flow of materials across the easy clean element. This forms a continuous slot which limits the contact of particles to two points in the screen slot and prevents plugging and avoids the stapling effect inherent with other filter media. In this way, the optimum efficiency is assured by maintaining the maximum effective flow area. OPTIONAL CONTROLS A) NEMA 4 (water and dust tight) control box, complete with solid state adjustable timers Backwash drive motor starter Indicator lights to indicate power on and unit flushing H.O.A. (Hands-Off-Auto) selector switch, permits changing from normal intermittent (differential operation) to continuous back-flushing Internally adjustable backwash timer for manual back-flush cycle start, recycle timer Differential pressure switch Full port ball valve complete with actuator, electric actuation B) Same as A) except the NEMA 4 control box is supplied with an input supply transformer for use at V, single phase, 50/60 Hz. C) Other as specified by specification or customer (example; control boxes NEMA 4X, 7, or 9, external alarm connection, pneumatic actuation, special wiring, specific brand components). MODEL ACM CONTROL SYSTEMS Every ACM strainer is shipped completely assembled, ready to operate. A single 1/3 H.P. motor drives the backwash mechanism of the largest strainer size. The automatic backwash controls (if required) actuate the backwash cycle. RAM automatic controls are engineered and designed to allow for optimal performance and ease of operation. They are factory set and field adjustable so as to provide for a minimal loss of backwash liquid and provide total cleaning of the easy clean elements. Where the loss of backwash liquid or solids is critical, RAM provides the model ACM. APPLICATION AND INDUSTRIAL USES ACM strainers are designed for removal of suspended particulate from all types of liquids, used in practically all industries for quenching, lubrication, spraying, cooling, descaling, pump, valve, heat exchanger and spray nozzle protection. Liquids filtered include well/lake, river, cooling tower or sea (salt water) to white water, black liquor (pulp and paper mills), chemicals, sewage and lubricating oils. 14 RAM LIQUID FILTRATION PRODUCT CATALOGUE 15
9 MODEL ACS AUTOMATIC STRAINER MODEL ACS AUTOMATIC STRAINER 5.0 The model ACS is a custom fabricated selfcleaning strainer designed for continuous backflush operation. Featuring a fabricated backwash arm and a single, replaceable element wedge-wire basket -both of stainless steel construction the model ACS is designed to be unattended for extended periods of time. The large amount of open area allows intermittent back-flush operation, thereby minimizing both operating costs and backwash effluent. The wedge-wire element features a reverse groove design that prevents lodging of debris in the element and creates a vortex during back-flush for a more efficient back-flush operation. The model ACS can be constructed from a variety of materials - from Pressure Drop Curves for ACS PRESSURE DROP CURVES 20 carbon steel to stainless steel to exotic alloys - or can be coated internally with fusion bonded epoxy finish, allowing it to handle any fluid. For a truly customizable strainer that can be designed for any application or budget, the ACS is the only choice. OPTIONAL AND STANDARD FEATURES Standard construction is carbon steel epoxy lined, available in stainless steel all grades, monel, SMO 254. Elements are standard as 304 stainless steel. All other materials are available. Standard unit complete with gear reducer and drive motor for continuous back-flushing. The standard TEFC motor is 1/220V, single phase, 50/60 Hz D - MIN SPACE HEAD/BASKET REMOVAL MOTOR WITH GEAR REDUCER PRESSURE CONNECTIONS B OUTLET 4X DIA. 4X DIA. 4X 45 DEG. 4X K THRU 45 DEG. K THRU INLET 4X J 4X J SECTION A-A SECTION A-A C H 4X L X L PAD 4X L X L PAD BACKWASH E OPTIONAL SPACE FOR CONROL PANEL & DIFF. PRESSURE SWITCH MOUNTING F INSPECTION PORT 3.0 DRAIN / BLOWDOWN Pressure Drop P.S.I OUTLET DRAIN DIMENSIONS (APPROX.) 150PSIG A A A Flow Rate (Water) G.P.M. (1/8" Slot) Values in the graph are used as a reference only. Dimensions are general, all information to be confirmed with design drawing. 16 RAM LIQUID FILTRATION PRODUCT CATALOGUE 17
10 MODEL ACS DESIGN, FEATURES & OPERATION MODEL ACS EASY CLEAN ELEMENTS RAM model ACS strainers are offered in capacities to 0,000 gallons per minute. The strainers are offered for vertical installation and available to degree of cleaning using easy clean elements. RAM model ACS strainer is a fabricated single body vessel with a single straining element. Designed as a fully automatic self-cleaning strainer. The vessel is available fabricated to ASME Code latest edition and addenda ( U stamped) and National Board Registered, or built in general accordance to ASME Code without code stamp or registration. In Canada, it is available also with CRN registration as required by province. Inlet and outlet connections are on the sides. The debris laden fluid enters the large lower chamber where it slows down and contaminants settle to the bottom. The fluid flows upward into the straining basket. The fluid then passes through the easy clean element and exits the strainer through the outlet nozzle. Contaminants gather on the inside of the basket in pockets created by the baskets vertical spacer rods. The backwash arms provide a flow path for the debris collected and the fluid to dislodge the debris during the backwash cycle. The backwash arms direct the dirty fluid to an open pit or tank at atmospheric pressure outside of the strainer. The arms rotate slowly to allow each section of the basket to be backwashed in turn. The backwash drive system converts the high rotational speed of the electric motor to a low rotational speed so as to more effectively backwash the straining basket. A shear pin protects the gear reducer, shafting and backwash arm from serious damage. The ACS strainer can perform self-cleaning (backwashing) without interruption of flow. These strainers are designed primarily for liquid service where large quantities of debris must be removed. RAM model ACS strainer uses a motor driven backwash arm to clean the strainer basket. A hollow shaft with two diametrically opposite arms rotates inside the basket and in turn blocks off a section of the basket. The two arms are open to the basket and to the atmosphere through the hollow shaft and backwash piping. Reversal of flow causes the debris and other contaminants to flow out through the backwash arm and out through a control valve to the drain. The strainer can be set for continuous backwash or automatic intermittent backwash operation. The backwash arm is driven by a standard motor through a reduction gear. Access opening is provided for inspection and removal of large pieces of debris accumulated at the bottom of the strainer. RAM model ACS easy clean element is cylindrical, made of reverse formed and resistance welded wedge-wires. Flow during straining is from the inside to the outside. Flow direction for backwashing, however, is opposite. The basket is a fabricated cage assembly that consists of a top, bottom and middle spacer ring that are fit and welded to the vertical spacer rods. The screen elements are constructed for easy replacement; they are bolted around the cage assembly in equal segments. The easy clean straining elements are available in reverse formed configuration to and are designed to give maximum open area and to deliver top performance in any straining application. OPTIONAL CONTROLS A) NEMA 4 (water and dust tight) control box, complete with solid state adjustable timers. Backwash drive motor starter Indicator lights to indicate Power on and unit Flushing H.D.A. (Hands-Off-Auto) selector switch, permits changing from normal intermittent (differential operation) to continuous back-flushing Internally adjustable backwash timer for manual back-flush cycle start, recycle timer. Differential pressure switch Full port ball valve complete with actuator, electric actuation B) Same as A) except the NEMA 4 control box is supplied with an input supply transformer for use at V, single phase, 50/60 Hz. C) Other as specified by specification or customer (example: control boxes NEMA 4X, 7, or 9, external alarm connection, pneumatic actuation, special wiring, specific brand components). ACS CONTROL SYSTEMS Every ACS strainer is shipped completely assembled, ready to operate. A single 1/3 H.P. motor drives the backwash mechanism of the largest strainer size. The automatic backwash controls (if required) actuate the backwash cycle. RAM Liquid Filtration automatic controls are engineered and designed to allow for optimal performance and ease of operation. They are factory set and field adjustable so as to provide for a minimal loss of backwash liquid and provide total cleaning of the east clean element. APPLICATION AND INDUSTRIAL USES ACS strainers are designed for removal of suspended particulate from all types of liquids, used in practically all industries for quenching, lubrication, spraying, cooling, descaling, pump, valve, heat exchanger and spray nozzle protection. Liquids filtered include well/lake, river, cooling tower or sea (salt water) to white water, black liquor (pulp and paper mills), chemicals, acids, sewage and lubricating oils. 18 RAM LIQUID FILTRATION PRODUCT CATALOGUE 19
11 MODEL FAFI & FAFX AUTOMATIC FILTER MODEL FAFI & FAFX AUTOMATIC FILTER DESIGN RAM modular filter systems consist of three (3) or more single filter units valved in parallel to common headers. The advantage of this type of filter system is that each filter unit can be individually backwashed either automatically, manually, or intermittently while the others remain on stream. PRINCIPLE OF OPERATION The filter works by unfiltered liquid entering the inlet header. It flows through the valve and upward through the filter media from outside to inside. The filtered liquid discharges through the outlet header at the top of the unit. BACKWASHING With the direction of flow (outside to inside), the solids build up on the outside of the filter elements. This makes the element very easy to backwash. Backwashing takes place when the differential pressure between the inlet header and outlet header reaches a preset level. At this point, the filter control module triggers a backwash sequence. In turn, each filter is cleaned while the other units remain on stream. INTERNAL OR EXTERNAL BACKWASHING Internal backwashing is when the filtered liquid is used for backwashing. External backwashing is when a secondary liquid is used. Internal backwashing is usually recommended where the process liquid is free flowing, inexpensive and plentiful. External backwashing is highly recommended when the operating pressure is too low for effective backwashing, or when it is not economically feasible. STANDARD FEATURES Positive basket seal to prevent by-pass Manual or fully automatic self cleaning Continuous flow even white backwashing Maintenance on each filter unit can be performed without shutting down the system Quick opening cover for easy access to filter media Reusable filter elements FLOW DIAGRAM FOR INDIVIDUAL CHAMBER EXTERNAL BACK-WASHING SYSTEM INTERNAL BACK-WASHING SYSTEM 20 RAM LIQUID FILTRATION PRODUCT CATALOGUE 21
12 MODEL FAFI & FAFX AUTOMATIC FILTER MODEL FAFI & FAFX AUTOMATIC FILTER The continuous wedge-shaped slots in the element effectively separates solids from the fluid passing through the unit. The unique RAM wedge design of the element offers high strength, high open area and less clogging than other types of elements. These 316 stainless steel screens are available from to 0.25 slot size. FABRIC RAM fabric media are woven from synthetic fibers and are chemically compatible with most liquids. Fabric media offers an excellent means of filtering liquids with retention levels down to nominal 5 microns. These synthetic fibers also have excellent solids release characteristics for easy cleaning. WIRE MESH Woven wire mesh screens provide good solids release characteristic. The wire mesh screens are made of type 316 stainless steel and wedge-wire inner backing is used to give it support. Wire mesh sizes are available from 1 micron to 0 micron. HOUSING MATERIAL: Standard construction is carbon steel internal epoxy coated and stainless steel, all grades. GASKETS: Available in buna-n, ethylene propylene (EPR), viton, silicone or teflon. FILTER MEDIA: Stainless steel, polyester or polypropylene. DESIGN PRESSURE: 150 psi and 300 psi standard construction. TEMPERATURE LIMITS: Temperature limits will vary depending on the gasket and screen material. FLOW RATE: Max. flow rate per element is 150 GPM. EXAMPLE: Determine filter size for 500 gpm using wedge-wire element with slot. 1. From Table 1 determine sizing factor. (which is 2.1). 2. Multiply the flow by the sizing factor to give us the factored flow. (ie. 500 x 2.1=1,050 factored flow). 3. From Chart 1 determine the number of elements needed. In our example for factored flow of 50, the number of elements needed is Table 2 gives the model # needed for either internal or external backwashing units. 5. Make sure that maximum flow rate per element is not exceeded. Divide the flow rate by the number of elements. The result should not exceed 0 gpm (500/5=0 gpm). FLOW FACTOR (TABLE 1) *Above sizing factor is based on filtering water. Dimensions are general, all information to be confirmed with design drawing. FLOW FACTOR (TABLE 2) SIZING CHART Number of Elements Required Units placed back-to-back are half the Length L. Dimensions are general, all information to be confirmed with design drawing. Factored Flow (GPM) X 0 22 RAM LIQUID FILTRATION PRODUCT CATALOGUE 23
13 RAM LIQUID FILTRATION 1311 Kerrisdale Boulevard, Newmarket, ON L3Y 8Z8
Series 774 Automatic Skid Package
Fluid Engineering 1432 Walnut St Erie, PA 16502 USA PH 814.453.5014 FAX 814.452.6573 www.fluideng.com sales @fluideng.com CONTINUOUS FLOW The Fluid Engineering 774 Strainer Package is designed to handle
More informationAutomatic Self-Cleaning Strainer/Filter Systems
Automatic Self-Cleaning Strainer/Filter Systems The Eliminator 1432 Walnut Street Erie, PA 16502 USA 814.453.5014 - PH 814.452.6573 - FAX www.fluideng.com The Hyper-Jet Engineered Products for Demanding
More informationBasket Strainers. Applications. Pressures to 3705 PSIG. Temperatures to 800ºF FEATURES MATERIALS OF CONSTRUCTION END CONNECTIONS SIZES RATINGS
Applications Process Industry Metals and Mining Power Industry Water & Waste Water Chemical Industry Pulp and Paper Oil and Gas Basket Strainers Pressures to 3705 PSIG FEATURES Temperatures to 800ºF Fabricated
More informationSeries 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW
Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating 1/4" NPT VENT 'A' 1/4" NPT 2 - REQ'D 'D' REQ D FOR BASKET REMOVAL 'B' FLOW 'C'
More informationAutomatic Self-Cleaning Strainer/Filter Systems
Fluid Engineering A Division of TM Industrial Supply, Inc. * An Employee-Owned Company 1432 Walnut Street Erie, PA 16502-1746 USA Phone (814) 453-5014 Fax (814) 452-6573 Email: sales@fluideng.com Web:
More informationSubject title Pipeline Strainers Cover subheadline Titel_englisch.indd :42:10 Uhr
Subject Pipeline title Strainers Cover subheadline Protecting Your Pumps, Filters, Nozzles, Flowmeters, Valves, Heat Exchangers, Condensers, Oil Burners, and Boilers From Pipeline Debris For over 75 years,
More informationRosedale Model HSS300 and HSS750 Single Cartridge Housings for Liquids
H S S S I N G L E C A R T R I D G E H O U S I N G S Rosedale Model HSS0 and HSS750 Single Cartridge Housings for Liquids Precision Machined Knife-Edge Seal The Rosedale Model HSS single element filter
More informationRP-CS 2-98 CERTA-SEAL LIQUID BAG FILTERS WITH THE MATCHED PERFORMANCE DESIGN. Products
RP-CS 2-98 CERTA-SEAL LIQUID BAG FILTERS WITH THE MATCHED PERFORMANCE DESIGN R Products INTRODUCING CERTA-SEAL LIQUID BAG FILTERS... A BETTER DESIGN RIGHT DOWN TO THE LAST NUT AND BOLT Plastic handles
More informationFabricated Duplex Strainers
Applications Chemical Industry Metals & Mining Process Industry Water & Waste Water Power Industry Pulp & Paper Oil & Gas Fabricated Duplex Strainers Pressures to 1480 PSIG Temperatures to 800ºF FEATURES
More informationAutoFilt RF3 Automatic Self-Cleaning Filter
AutoFilt RF3 Automatic Self-Cleaning Filter DESIGN The AutoFilt RF3 is an automatic self-cleaning filtration system designed for continuous maintenance-free filtration for all major manufacturing and processing
More informationAutoFilt RF3 Automatic Self-Cleaning Filter
AutoFilt RF3 Automatic Self-Cleaning Filter DESIGN COST EFFECTIVENESS TECHNICAL DATA Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (800) 426-5480 www.cmafh.com
More informationPortable Liquid Pump and Filter Systems Compressed Air-Powered Pump and Filter System
Portable Liquid Pump and Filter Systems Compressed Air-Powered Pump and Filter System Technical Bulletin C PORTABLE LIQUID PUMP AND FILTER SYSTEMS DESCRIPTION Filtration Systems Portable Liquid Pump &
More informationPRODUCT BROCHURE AUTOMATIC AND MANUAL. filtration systems BOLLFILTER UK LIMITED
PRODUCT BROCHURE AUTOMATIC AND MANUAL filtration systems UK LIMITED EFFICIENT, LOW MAINTENANCE filtration systems The Boll & Kirch Product Range incorporates a comprehensive selection of quality filters
More informationCartridge Filter Housings Nowata A Series
Cartridge Filter Housings Nowata A Series Customization May Change the Model Number Designation to B, D or F Series 1. Introduction All A series cartridge filter housings are designed for efficient liquid
More informationSeries RFLD Duplex In-Line Filter
APPLICATION Series RFLD Duplex In-Line Filter Welded Pressures to 230 psi Flows to 3900 gpm HYDAC RFLD in-line filters are designed for in-line mounting and are mainly used in continuously operating systems.
More informationSuction Diffusers. Applications PROTECTION PUMP. Pressures to 790 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS SIZE RANGES RATINGS
Applications Process Industry Metals and Mining Power Industry Water and Waste Chemical Industry Pulp and Paper Oil and Gas Suction Diffusers Pressures to 790 PSIG Temperatures to 800ºF FEATURES Filtration
More informationSeries RFL In-Line Filter
APPLICATION Series RFL In-Line Filter Pressures 2 bar Flows to 400 l/min HYDAC RFL In-Line Filters are designed for in-line mounting. These filters can be used in hydraulic, flushing, and for extraction
More informationFabricated Tee Strainers Style T & TQ; 150#, 300# and 600# Flanged or Butt Weld Connections...6 Technical Data...7
07/1 Fabricated Strainers Fabricated Y Strainers Style FSA & FSSA; 10#, 00# and 600# Flanged or Butt Weld Connections... Technical Data... Style FSA & FSSA; 900#, 100# and 00# Flanged or Butt Weld Connections...*
More informationDistributed By: M&M Control Service, Inc
Fabricated Strainers Fabricated Y Strainers Style FSA & FSSA; 150#, 300# and 600# Flanged or Butt Weld Connections...2 Technical Data...3 Style FSA & FSSA; 900#, 1500# and 2500# Flanged or Butt Weld Connections...*
More informationHAYWARD FILTRATION AUTOMATIC SELF-CLEANING & FABRICATED PIPELINE STRAINERS
HAYWARD FILTRATION AUTOMATIC SELF-CLEANING & FABRICATED PIPELINE STRAINERS AUTOMATIC SELF-CLEANING STRAINERS The Hayward automatic self-cleaning strainer is a motorized strainer designed for the continuous
More informationTStrainers. Applications. Pressures to 3705 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS SIZES RATINGS
Applications Steam, Liquid, Gas and Oil Service Process Equipment Water and Waste Power Industry Pulp and Paper Chemical Industry Metals and Mining TStrainers Pressures to 3705 PSIG Temperatures to 800ºF
More informationFILTERS, STRAINERS AND VALVES PRODUCT GUIDE
FILTERS, STRAINERS AND VALVES PRODUCT GUIDE TEE FILTERS INLINE FILTERS BRASS FILTERS SPIN ON FILTERS OFF-LINE FILTRATION Y STRAINERS BASKET STRAINERS DUPLEX STRAINERS STRAINING ELEMENTS FRP STRAINERS DUAL
More informationLF/LFM - Low Pressure High Flow Assemblies LF flow rate to 560 lpm, 150 gpm / LFM flow rate to lpm, 4500 gpm.
HY-PRO FILTRATION LF/LFM - Low Pressure High Flow Assemblies LF flow rate to 560 lpm, 150 gpm / LFM flow rate to 16875 lpm, 4500 gpm Features, Benefits, Advantages Carbon steel construction standard (304
More informationHIGH PRESSURE FILTERS
HIGH PRESSURE FILTERS Series DF & LF Pressures to 6 PSI Flows to 18 GPM APPLICATION HYDAC DF & LF In-line High Pressure Filters are designed for use on hydraulic power units, machine tools, plastics machinery,
More informationBackwashable Filter Systems ProGuard 2000 Series
Backwashable Filter Systems ProGuard 2000 Series Continuous Filtration System for Liquids and Slurries Automatic Backwashing Capabilities 1. Introduction The ProGuard 2000 series tubular backwash filters
More informationHIGH PRESSURE FILTERS
APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 4 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold block
More informationTo ensure proper installation, digital pictures with contact information to before startup.
Check List for Optimal Filter Performance? There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and 2 valve should have a 3 waste line. Do not use rubber hosing or
More informationHIGH PRESSURE FILTERS
APPLICATION HIGH PRESSURE FILTERS For Manifold Block Side Mounting Series DF...QE Pressures to 4 psi Flows to 18 gpm HYDAC DF...QE High Pressure Filters are designed to be side mounted directly onto the
More informationTechnical Data P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP SD 9952B
Technical Data SD 9952B SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NEW YORK, 12586-2035 P3 PISTON POWER PUMP NON-ELECTRIC CONDENSATE PUMP Pressures To 250 PSIG (20.7 barg) Temperatures
More informationTemporary Strainers. Applications. Pressures to 3705 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS SIZES
Applications Process Industry Water and Waste Water Power Industry Pulp and Paper Chemical Industry Marine Oil and Gas Steel Mills Metals and Mining Temporary Strainers Pressures to 3705 PSIG Temperatures
More informationCAT231.1 PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø OPERATING CONDITIONS 25 TO 100 PSI 100 F MAX IMUM TEMPERATURE SERIES METER
CAT231.1 STANDARD FEATURES TASK MASTER III - 1 ½ / 2 - FIVE CYCLE 316 STAINLESS STEEL VALVE - SIDE MOUNT SUPER FLOW KIT S ON 2, 3 & 4 SYSTEMS (SERVICE FLOW BYPASS DIAPHRAGM VALVES) ERCt ELECTRONIC TIMER
More informationHARMSCO Hurricane Swing Bolt Water Filters Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL
Models: HUR 1X170FL, HUR 3X170FL HUR 5X170FL, & HUR 8X170FL INSTALLATION AND OPERATION MANUAL HUR 8X170FL HUR 5X170FL HUR 3X170FL HUR 1X170FL Harmsco Filtration Products With Patented Up-Flow and Tangential/Rotational
More informationSpin Klin 12" Super Flow
Spin Klin 12" Super Flow w w w. a r k a l - f i l t e r s. c o m Galaxy Super Flow Spin Klin Battery Standard Automatic Backwash Operation and Maintenance Manual Filtration Process During filtration, water
More informationSECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY
SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure
More informationThe Anatomy of a Drum Filter
The Anatomy of a Drum Filter Theory of Operation Dirty air is introduced into the Drum Filter Enclosure The Main System Fan pulls the air across the filter media The dirty particles are vacuumed off the
More informationMAHLE Automatic Filter Series R8-30W
MAHLE Automatic Filter Series R8-30W With internal pressure segment cleaning, rated pressure to 150 psi Connection Sizes: ANSI 8" to ANSI 20", welded design 1. Features Powerful, fully automatic filtration
More informationD-023 PN 16 / 25. Combination Air Valve for Wastewater PATENTED. Description. Applications. Operation. Main Features
PN 16 / 25 Wastewater Combination Air Valve for Wastewater PATENTED EuroC-D023SWG-15-2 Description The D-023 Combination Air Valve combines an air & vacuum component and an air release component in a single
More informationTechnical Data. Series Oval Flowmeter. Model 9400
Technical Data Series Oval Flowmeter Model 9400 General The Brodie 9400 Series Oval Flowmeters, Models 9402 through 9459 (sizes 1/2-3 ), are mechanical, positive displacement meters designed for use in
More informationARKAL FILTERS CATALOGUE
ARKAL FILTERS CATALOGUE Content DISC FILTERS - TECHNOLOGY 4 Automatic Filters Compact 6 2" Compact All Plastic 8 Opal 10 2" Poly Battery 12 Crystal 14 3" Poly Battery 16 Galaxy 18 Galaxy Polymer 20 Manual
More informationDETAILED EQUIPMENT SPECIFICATION MHC SERIES WATER SOFTENERS
2227 South Street P.O. Box 044170 Racine, Wisconsin 53404-7003 Phone: 262-681-1300 Fax: 262-681-1318 www.marlo-inc.com DETAILED EQUIPMENT SPECIFICATION MHC SERIES WATER SOFTENERS 1.0 SCOPE 1.1 Provide
More informationPRESSURE REDUCING VALVE
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING VALVE with LOW-FLOW BY-PASS FEATURE Main Line valve
More informationPRESSURE REDUCING VALVE
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Closes quickly when downstream pressure exceeds reduced pressure setpoint 3 PRESSURE REDUCING VALVE with SURGE
More informationLiquid Strainers. Protect nozzles, valves and pumps from damaging debris. Experts in Spray Technology Spray Nozzles. Spray Fabrication.
Experts in Technology Nozzles Control Analysis Fabrication Liquid Strainers Protect nozzles, valves and pumps from damaging debris. Table of Contents T Strainers Low to Medium Pressure TW...3 TWC...3 TWF...4
More informationMustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.
PRESSURE REDUCING CONTROL VALVE 02/09 Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Reducing setpoint is adjustable 2 (AOS) P/L Standard Components 1 Main Valve
More informationNFHD Modular Duplex Filter System Pressures to 360 psi Flows to 450 gpm 4 Ports
NFHD Modular Duplex Filter System Pressures to 360 psi Flows to 450 gpm 4 Ports PPLICTIONS HYDC NFHD Return Line Filters are designed for use on hydraulic power units, machine tools, plastics injection
More informationDuctile Iron, Jacketed Pumps: Catalog Section 1602 Cast Iron, Non-Jacketed Pumps: Catalog Section 1401 HL4126A
Page 1601.1 TABLE OF CONTENTS Features & Benefits...2 Port Location Options...2 Model Number Key...3 Standard Materials of Construction...3 Cutaway View & Pump Features...4 Special Materials & Options
More informationCAT231.1 SHUT OFF KIT (SOK) TO PREVENT BYPASS PRESSURE GAUGE AND TEST TAP KIT SKID MOUNTING 220V, 50HZ, 1Ø
CAT231.1 STANDARD TASK MASTER III - 1 ½ VALVE 316 SS - SIDE MOUNT SERVICE FLOW BYPASS DIAPHRAGM VALVES. ERCt ELECTRONIC TIMER 100 PSI EPOXY LINED AND COATED CARBON STEEL MINERAL TANKS ACCUMATIC BRINE SYSTEM.
More informationPRESSURE REDUCING CONTROL VALVE
PRESSURE REDUCING CONTROL VALVE 06/08 Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Reducing setpoint is adjustable 2 (AOS) X P/L Standard Components 1 Main
More informationYStrainers. Applications. Pressures to 3705 PSIG Temperatures to 800ºF FEATURES MATERIALS END CONNECTIONS RATINGS SIZES
Applications Process Industry Metals and Mining Power Industry Water and Waste Chemical Industry Pulp and Paper Oil and Gas YStrainers Pressures to 3705 PSIG Temperatures to 800ºF FEATURES Low pressure
More informationPRESSURE GAGES AND TEST TAPS
CAT 500.1 FRF series filters. Polyglass 100 psi vessels with top mount Task Master II 1 ½ valve and single point PVC internals. FMF series filters. Carbon steel epoxy lined and coated vessels with side
More informationHIGH PRESSURE FILTERS
APPLICATION HIGH PRESSURE FILTERS For Manifold Block Mounting Series DF...P Pressures to 45 psi Flows to 18 gpm HYDAC DF...P High Pressure Filters are designed to be mounted directly onto the manifold
More informationPRESSURE REDUCING VALVE
Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Low Flow By-Pass controls at low flows 4 PRESSURE REDUCING VALVE with LOW-FLOW BY-PASS FEATURE Main Line valve
More informationOverview of Technical Advantages and Product Design. G.S. Presser, P. Eng. November 2004
Acme Automatic Scraper Strainers Overview of Technical Advantages and Product Design G.S. Presser, P. Eng. November 2004 Advantages of Scraper Strainers Can automatically remove large and small particles,
More informationFLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)
FLOOD PROTECTION SHUT DOWN VALVE ( and smaller) 01/10 2 6 To Floor Drain L X JB11 4 FS99 5 Installed upstream of Reduced Zone Backflow Preventer. Normally Open Valve - Closes when discharge from RPZ Relief
More informationNFH Low Pressure Filters
PPLICTIONS NFH Low Pressure Filters Pressures to 360 psi Flows to 450 gpm Water Removal Capability 4 Ports HYDC NFH In-line Return Filters are designed for use on hydraulic power units, machine tools,
More informationCrosby Series BP OMNI-TRIM Pressure Relief Valves for applications involving variable back pressure.
CROSBY Crosby Series BP OMNI-TRIM Pressure Relief Valves for applications involving variable back pressure. Features The balanced piston design offsets the effects of variable back pressure on valve set
More informationMark 5108 Series. Back Pressure Regulating Valves Mark 5108 Series. Back Pressure Regulating Valves. Valve Features. Operation
Mark 5108 Series Back Pressure Regulating Valves In many liquid piping systems, it is vital that line pressure is maintained within relatively narrow limits. The Mark 5108 is designed to do just that.
More informationIndustrial Turbo Meters, Sizes 2" through 6"
Industrial Turbo Meters Sizes 2" through 6" TUR-UM-00530-EN-19 (October 2014) User Manual Industrial Turbo Meters, Sizes 2" through 6" User Manual CONTENTS Scope of the Manual 5 Specifications 5 Product
More informationVAF TM FILTRATION SYSTEMS HYDROCYCLONE SEPARATOR
VAF TM FILTRATION SYSTEMS HYDROCYCLONE SEPARATOR GENERAL INFORMATON Evoqua s VAF TM brand Hydrocyclone Separators are effective in removing suspended particles from any flow stream of water where the specific
More informationBackflushing Filter AutoFilt RF3
Backflushing Filter AutoFilt C 2,5 4 6 8 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL The automatic back-flushing filter AutoFilt is a self-cleaning system for extracting particles from lowviscosity fluids.
More informationBERMAD Irrigation. Media Filtration Systems. Model Filters. Features and Benefits. Typical Applications
BERMAD Irrigation Media Systems Model 4000 BERMAD sand media filtration systems offer a low maintenance and efficient method to filter organic material and fine inorganic particulate from irrigation system
More informationBGT Series. Low Pressure Filters
Low Pressure Filters 60 Applications - Flows to 640 GPM - 3 Micron Absolute to 120 Micron Absolute - Disposable or Recleanable Elements - Visual and Electrical Indicators - Microglass elements - Magnetic
More informationAutomatic Back-Flushing Filter for Process Technology AutoFilt RF3.
Automatic Back-Flushing Filter for Process Technology AutoFilt RF3. AutoFilt RF3: So automatic, The Challenge Particle contamination in process water and other operating fluids accelerates the rate of
More informationLAKOS AUTOMATIC SELF-CLEANING SCREEN FILTERS
LAKOS AUTOMATIC SELF-CLEANING SCREEN FILTERS Low-maintenance, high-efficiency, high-flow screen filtration in a compact footprint APPLICATIONS Industrial Process cooling Chilled water Water treatment Flow
More informationDESIGNER S GUIDE STRAINERS INTERNATIONAL
Y Strainers Basket Strainers T-Strainers Automatic Backwash Strainers Duplex Strainers Suction Diffusers Butterfly Valves Check Valves INTERNATIONAL DESIGNER S GUIDE Formerly SSI Equipment, now manufactured
More informationThompson Strainer MLS-2
Serial Number Location GENERAL SPECIFICATIONS: - Maximum Flow: GPM (No minimum flow requirement). - Maximum Pressure: 5 PSI (Higher pressure models available). - Not Designed for Suction / Vacuum. - Screen
More informationInstallation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC
Installation, Operation & Service Manual PPL Bag Filter Housings Eaton Filtration, LLC 900 Fairmount Avenue, Elizabeth, NJ 07207 Read all instructions before installation or operation of equipment. Failure
More information25 mm (1 in), 38 mm (1-1/2 in) & 50 mm (2 in) TYPE S FLOWMETERS WITH MODEL 157 AND 800 SERIES REGISTERS
TS- Rev. B Type S lowmeters 1, 1 1 2 & 2 mm (1 in), mm (1-1/2 in) & mm (2 in) TYPE S LOWMETERS WITH MODEL 7 AND 8 SERIES REGISTERS 1-1/2" Type S with Model 7 Register SPECIICATIONS 1" Type S with Model
More informationProcess Inline Filter Protective filter PLF2-9HF
Process Inline Filter Protective filter PLF2-9HF Specifications Nominal size: DN 300 - DN 600 Q s max: 3000 m 3 /h p s max: 16 bar Filtration ratings: 1-90 µm 1. GENERAL Product description Protective
More informationMark 6127 Series. Pressure Regulators Mark 6127 Series. Pressure Reducing Valves. Valve Features. Operation
Mark 6127 Series Pressure Reducing Valves The primary function of the Mark 6127 is to reduce a greater upstream pressure to a lesser, more manageable downstream pressure, operating without regard to either
More informationUNIVERSAL PRODUCT LINE: STAINLESS STEEL NON-JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE:
Page 1701.1 TABLE OF CONTENTS Features & Benefits...2 Port Location Options...2 Model Number Key...3 Standard Materials of Construction...3 Cutaway View & Pump Features...4 Special Materials & Options
More informationDETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS
5356 Hillside Avenue Indianapolis, IN 46220 P: +1 888-56-Water (569-2837) F: +1 317-255-4727 info@nancrede.com www.nancrede.com DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS 1.0 SCOPE 1.1
More information2900 MPV Series. Consolidated * Valves. Pilot-Operated Safety Relief Valve
Technical Specifications Rev.A - 07/2018 Consolidated * Valves 2900 MPV Series Pilot-Operated Safety Relief Valve A unique design that combines top performance, capabilities and features within an economical,
More informationPUMPS AND FILTRATION
Rain Bird applies its industry leading irrigation expertise to the design and manufacture of pump stations and filtration products. By doing so, Rain Bird is the only irrigation manufacturer able to provide
More informationMAP Automatic Strainers In-Line Series
MAP Automatic Strainers In-Line Series flow rate filtration degrees inlet / outlet diameters min. operating pressure up to 4.500 m 3 /h (19.800 gpm) 5.000 200 micron up to DN800 (32 ) 1 bar (15 psi) Heavy
More informationAURORA FILTERS. - S 316L Stainless Steel AF-LD C C22 Hastelloy AF-PC-001/2/3/4/5 Flange Type Designation Code
49 Passmore Ave., Toronto, ON, Canada TF 1-888-368-8884 P 416-299-3311 F 416-299-3387 www.aurorafilters.com AURORA FILTERS Introduction AURORA FILTERS has developed a line of portable Filter Systems that
More informationLEAD FREE * LFF115 (Globe) LFF1115 (Angle)
ES-ACV-SB-LFF115_LFF1115 LEAD FREE * Pressure Reducing Control Valve Schematics Throttles to reduce high upstream pressure to constant lower downstream pressure Reducing setpoint is adjustable 2 (AOS)
More informationCrispin Valves Operating Guide. Crispin
Crispin Valves Operating Guide Crispin Since 1905 Crispin Multiplex Manufacturing Co. 600 Fowler Avenue Berwick, PA 18603 1-800-AIR-VALV T: (570) 752-4524 F: (570) 752-4962 www.crispinvalve.com sales@crispinvalve.com
More informationFiltration Solutions. Cover subheadline. Engineered for performance and value in a variety of applications.
AFC-Series Backwash/Tubular Tubular/Backwashing Filter Systems F-Series Filter Systems Liquid Cover headline Filtration Solutions Cover subheadline North America 95 Shaver Road Portage, Michigan 4904 USA
More informationHayward FLT Series Cartridge Filters. Features. Webster In-Tank Filtration Systems
HAYWARD FILTERS Hayward FLT Series Cartridge Filters Designed for the most demanding applications these all plastic cartridge filters are used to filter fine particles from the process fluid. Models are
More informationLIQUID MEASUREMENT STATION DESIGN Class No
LIQUID MEASUREMENT STATION DESIGN Class No. 2230.1 Michael Frey Systems Sales Manager Daniel Measurement & Control, Inc. 5650 Brittmoore Rd. Houston, Texas 77041 INTRODUCTION The industry continues to
More informationTable Of Contents. 1 Tel Fax Toll Free Tel Toll Free Fax
Table Of Contents IFC Simplex Basket Strainers Simplex Basket Strainers............................................2 IFC Series B125 and B300 Style 2 Threaded and Socket Weld Basket Strainers........3
More informationTransportation Products
Transportation Products Butterfly Valves Hopper Tees Actuators Accessories A Name You ve Trusted for Years... Resilient Seated Butterfly Valves 400 & 480 Series 1 Piece Body Design This economical, resilient
More informationSelection Guide Ultipleat High Flow Filter System
Element Data Sheet GDS 131a Selection Guide Ultipleat High Flow Filter System Description The Ultipleat High Flow filter is a large diameter, coreless, single open ended, pleated cartridge with an inside
More information* Contact your sales representative for compliance to NACE MR or later requirements.
VALVES & CONTROLS crosby SERIES 800, 900 OMNI-TRIM, AND BP OMNI-TRIM Crosby s Series 800 adjustable blowdown, Series 900 fixed blowdown OMNI-TRIM, and BP OMNI-TRIM full nozzle pressure relief valves have
More informationHY-PRO FILTRATION. FSL Filter Unit Flow rate up to 22 gpm (83 lpm)
FSL HY-PRO FILTRATION Materials of Construction Assembly Frame: Painted Steel Drip Pan: Painted Steel Filter Assembly: Epoxy coated steel 25 or 50 psid bypass available True differential pressure indicator
More informationCheck Valve MODEL. Schematic Diagram. Product Dimensions Data:
Check Valve Simple Proven Design No-Slam Operation Drip-Tight Shut-Off No Packing Glands or Stuffing Boxes Easy to Install & Maintain 8-0 (Full Internal Port) MODEL 68-0 (Reduced Internal Port) The Cla-Val
More informationLEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology
Technical Bulletin TB-ACV-LFF11RFP_SentryPlus LEAD FREE * LFF11RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology Installed upstream of Reduced Zone Backflow Preventer.
More informationYARWAY HANCOCK Y-PATTERN FORGED STEEL GLOBE STOP VALVES SERIES 4000
Direct contact and metal-to-metal seating make this Y-pattern globe stop valve ideal for most shut-off applications. FEATURES All valves feature integral Stellite hardfacing on both body and disc seating
More informationUNIVERSAL PRODUCT LINE: DUCTILE IRON JACKETED PUMPS TABLE OF CONTENTS SERIES DESCRIPTION RELATED PRODUCTS OPERATING RANGE
Page 1602.1 TABLE OF CONTENTS Features & Benefits...2 Porting & Sealing...2 Jacketing...2 Revolvable Pump Casings...2 Cutaway View & Pump Features...3 Model Number Key...4 Standard Materials of Construction...4
More informationWARCO CHEMAG SERIES GH FILTERS
WARCO CHEMAG SERIES GH FILTERS High Performance Pleated & Bag Type Filtration Systems INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS Thank you for your purchase of a WARCO Series GH Filtration System.
More informationFiltomat M100/MG Filters
Filtomat M100/MG Filters Hydraulic self-cleaning screen filters, with no external power source required flow rates M100: up to 400 m 3 /h (1,760 gpm) MG: up to 800 m 3 /h (3,520 gpm) minimum operating
More informationSeries Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications.
7 YARWAY Hancock T-Pattern Globe valves Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications Features Heavy integral stellite hardfacing on
More informationFilter & Strainer. The primary difference between filters and strainers is in the size of the particulates they are removing.
Filter & Strainer Filters and strainers do have a lot in common. Both products are designed to remove suspended particles from a liquid or gas. They also both deliver similar benefits by protecting downstream
More information8L SERIES THREE SCREW PUMPS
TM 8L SERIES THREE SCREW PUMPS The reliable pump people ROTARY SCREW PUMPS Performance Shown at 1500 PSID (103 BAR), 200 SSU (43 CST) 60 HZ: 870 1150 1750 50 HZ: 960 1450 1200 1100 630M 40 250 1000 900
More informationSeries Split Coupled Vertical In-Line Pumps. File no.: 43.10in Date: august 14, 2013 Supersedes: 43.10in Date:
Series 00 Split Coupled Vertical In-Line Pumps File no.:.0in Date: august, 0 Supersedes:.0in Date: february 0, 0 Series 00 Best commercial hvac pump design available since 99 Life cycle value at every
More informationCheck List for Optimal Filter Performance
Check List for Optimal Filter Performance There should be no back-pressure on the flush line. A 1 valve should have a 2 waste line, and a 1.5" or 2 valve should have a 3 waste line. Do not use rubber hosing
More informationLEAD FREE * LFM115 (Globe) LFM1115 (Angle)
ES-ACV-SB-LFM115_LFM1115 LEAD FREE * Pressure Reducing Control Valve Schematic Throttles to reduce high upstream pressure to constant lower downstream pressure Reducing setpoint is adjustable 2 (AOS) P/L
More informationPWA-IL B73.2 IN-LINE
PWA-IL ANSI/ASME B73.2 IN-LINE PROCESS PUMP PWA-IL ANSI/ASME B73.2 IN-LINE PROCESS PUMP COMPETITIVE ADVANTAGES vs. Ductile Iron n High-strength, impact resistant liquid ends for improved durability and
More informationAIRPRO MAX AIR VALVES. Engineering Creative Solutions for Fluid Systems Since 1901
AIRPRO MAX AIR VALVES Engineering Creative Solutions for Fluid Systems Since 0 TABLE OF CONTENTS AIRPRO MAX AIR VALVES Air Release Valve Data and Sizing Guide... Air Vacuum Valve Data and Sizing Guide...-
More information