Size: px
Start display at page:

Download "Snap-Action Switches Detection Switches General Catalogue Panasonic... the new name for"

Transcription

1 Snap-Action Switches Detection Switches General Catalogue 2005 Panasonic... the new name for

2 TABLE OF CONTENTS Page Selector Chart...4 Technical Terminology & Cautions For Use...10 Turquoise Switches...14 Notes For Turquoise Switches...15 Turquoise Stroke Switches...17 Turquoise Switch J Type (ABJ)...25 S Type (ABS)...35 V Type (ABV)...46 Basic Switch NZ (AM1)...51 Miniature Switch QV (AM5)...60 QV (AM5): Contact gap is more than 1mm type...73 NV (AH7): Heat resistant...74 Subminiature Switch FS/FS-T (AV3/AVT3/AVM3/AVL3)...80 FS (AV3 G): Contact gap is more than 1mm type...92 PS (AVM3 P)...94 CS (AV6)...99 Ultra-miniature Switch FJ (AH1) Smallest Snap-action Switch FU (AV4) Inter Lock Switch GX (AGX) GW (AV1) GL (AGL) Detection Switch FT-2Way Switch (ABC3) FT-µ (ABC2) FT (ABC1) FP (ABP8) New FD (ABU8) Tip (AHF2) Standards Chart

3 Matsushita Electric Works Switch Series Covers All Markets High Environmental Resistance Turquoise Colored Seal Switches P.14 New silent switch with both-sided sliding contact. Boosted employability with ultra-long stroke. IP67 type (Immersion protected) Automotive Cultivator Multistory car park Electric cart Refrigerator Turquoise Stroke Switches Turquoise Switches NEW S type J type V type Snap-action Switch Series with Plenty of Variation P.51 Full lineup of U, J, S, V and Z types. Air conditioner Microwave oven Vending machine Vacuum cleaner Heater FU Switches FJ Switches PS Switches FS/FS-T Switches CS Switches NV Switches QV Switches NZ Basic Switches Pin plunger (Heat resistant type)

4 Environmental resistance Compact Minute current type Miniature Detection Switches Suited for mobile equipment that require compactness and low energy consumption. High reliability at low level load. Smallest worldwide* in its class: 2-directional single ultra-compact detection switch Mobile phone Digital still camera Laptop computer CD-RW FT-2 Way Switches NEW NEW Addition of Long Stroke type FT-µ Switches World s smallest class (1a) (1b).055 (Unit: ) P.126 Silicon audio player FT Switches FP Switches New FD Switches *MEW data as of Aug., Contributes to safety countermeasures by detecting machine tilt. TIP Switches Containing a photo sensor Door Interlock Switch for Office Automation Equipment Complies with safety standards. P.114 GX Switches GW Switches GL Switches For 1-circuit line For 1-circuit line For 2-circuit lines PPC

5 Switch Selector Chart Type of switch J type (Stroke switches) NEW Turquoise J type S type V type Features Compact size and ultralong stroke IP67 Silent operation ASQ ABJ ABS Ultra-miniature size ( mm inch) Adoption of elastomer double molding technology and Ultrasonic swaging technology to uniform sealing in high production quantities High environmental resistance Subminiature size ( mm inch) Adoption of Elastomer double molding technology and Ultrasonic swaging technology to uniform sealing in high production quantities High environmental resistance ABV1 Miniature size ( mm inch) Adoption of Ultrasonic swaging technology and epoxy sealing to uniform sealing in high production quantities High environmental resistance O.F. by pin plunger (gf, Max.) 1.5N (Pin plunger) 1.7N (Leaf lever) 1.5N (Simulated leaf lever) 1.23N 1.96N 2.45N (Long stroke type) 0.98N 1.47N 0.98N 1.96N Max. contact rating (resistive) Rating of low-level circuit type (resistive) Gold plating on both sides of sliding contact 100 ma 30 V DC 1 ma 5 V DC Silver alloy contact Silver alloy contact Silver alloy contact 1.96N type 2 A 125 V AC 2 A 30 V DC O.F. 1.23N 1 A 125 V AC 1 A 30 V DC O.F. 2.45N (Long stroke type) 1 A 125 V AC 1 A 30 V DC Gold-clad contact 0.1 A 125 V AC 0.1 A 30 V DC 5 ma 6 V DC 2 ma 12 V DC 1 ma 24 V DC 2 A 125 V AC 2 A 250 V AC 2 A 30 V DC 0.4 A 125 V DC Gold-clad contact (triple layer) (double layer) 0.1 A 125 V AC 0.1 A 250 V AC 0.1 A 30 V DC 5 ma 6 V DC 2 ma 12 V DC 1 ma 24 V DC 5 A 250 V AC (O.F. min. 1.96N) 3 A 250V AC (O.F. 0.98N) Gold-clad contact 3 A 250 V AC (O.F. min. 1.96N) 1 A 250 V AC (O.F. 0.98N) 5 ma 6 V DC 2 ma 12 V DC 1 ma 24 V DC Expected life (min. ope.) Electrical (Nominal rating) (Low-level rating) (Silver alloy contact type) 10 5 (Gold-clad contact type) (Silver alloy contact type) (Gold-clad contact type) 10 5 (Nominal rating) Mechanical (Low-level rating) Quickconnect Solder Terminal style Screw PC board Lead wire (IP67) Connector Contact material Gold-clad (Standard) Silver alloy (Low-level) Gold-clad (Standard) Silver alloy (Low-level) Gold-clad (Standard) Silver alloy (Low-level) Gold-clad UL, CSA,VDE, SEMKO UL/CSA UL/CSA/VDE/SEMKO UL/CSA/VDE/SEMKO Page

6 Basic Miniature NZ QV NV heat resistant Unit: Versatile range for all applications AM1 AM5 AH7 Reliable design with shock resistance Continuous use at 120 C (248 F) possible High inrush current resistance 0.1 A to 21 A type available 0.69N to 5.30N 0.49N to 3.92N <Silver alloy contact> 0.49N to 3.92N <Gold-clad contact> 0.49N to 1.96N Silver alloy contact Silver alloy contact 15 A 125, 250 or 480 V AC 1/8HP 125 V AC 1/4HP 250 V AC 1/2A 125 V DC 1/4A 250 V DC 21 A 250 V AC (EOL)* 16 A 250 V AC 11 A 250 V AC 6 A 250 V AC *Product is end of life Gold-clad contact 0.1 A 250 V AC 5 ma 6 V DC 2 ma 12 V DC 1 ma 24 V DC 16 A 250 V AC 10 A 250 V AC 5 A 250 V AC Gold-clad contact 3 A 250 V AC 1 A 250 V AC 5 ma 6 V DC 2 ma 12 V DC 1 ma 24 V DC (Nominal rating) (Low-level rating) Silver alloy (Standard) Silver alloy (Low-level) Gold-clad silver alloy Silver alloy UL/CSA UL/CSA/VDE/SEMKO UL/CSA/VDE/SEMKO

7 Switch Selector Chart FS/FS-T Subminiature FS: Greater than 1mm of contact gap PS CS Type of switch Features AV3/AVT3/AVM3/AVL3 AV3 AVM3 AV6 Consistent quality and high precision through sophisticated automatic fabrication system Low-level circuit types available Long life version available Contact gap of greater than 1mm.039inch Door inter-lock switch for OA equipment High capacity micro switch In-line terminals make soldering works easy Using a connector for connections significantly improves operation effectiveness Contact reliability is achived by simple dust prevension guard and gold-clad double layer contacts O.F. by pin plunger (gf, Max.) <Standard> 0.25N (Gold-clad) 0.49N 0.98N <Long life version> 1.47N 1.47N 1.47N 0.50N 1.50N Max. contact rating (resistive) Rating of low-level circuit type (resistive) <Standard> 3 A 250 V AC 3 A 30 V DC 0.4 A 125 V DC <Long life version> 5 A 250 V AC 5 A 30 V DC 0.4 A 125 V DC <Au clad contact> 0.1 A 250 V AC (Triple layer) 0.1 A 30 V DC 1 to 100 ma, 5 to 30 V DC (Double layer) 1 to 100 ma, 5 to 250 V AC (Triple layer) 3 A 30 V AC 10.1 A 250 V AC 0.1 A 30 V DC Expected life (min. ope.) Electrical Mechanical (Long life version) Quickconnect Solder Terminal style Screw PC board Lead wire Contact material Connector (Standard) Silver alloy (Low-level) Gold-clad triple layer, double layer Silver alloy Silver alloy Gold-clad silver alloy UL, CSA,VDE, SEMKO UL/CSA/VDE/SEMKO UL/CSA/TÜV/SEMKO UL/CSA/(VDE)/SEMKO UL/CSA/TÜV Page

8 Unit: Ultra-miniature Inter Lock Switch FJ FU GX GW GL Ultra-miniature size ( mm/ mm inch/ inch) Flux-resistant construction Flat terminal AH1 AV4 AGX AV1 AGL4 Super miniature size ( mm inch) Solder terminal type with mounting holes available Mechanical life Snap-in mounting type Satisfying the downsizing needs 14 mm.551 inch in depth Contact gap of greater than 4 mm.157 inch Dual restoration spring mechanism Insuration distance 8 mm (snap-in mounting 2 form A and 3 form A type) 2-circuit line high capacity load contact and low-level circuit load contact 0.74N 1.47N 0.98N <Standard> 1a: 3.92N 2a: 3.92N 3a: 5.88N <High capacity> 1a: 4.90N 2a 3a: 5.88N 1a: 4.90N 1b: 2.94N 1a1b: 5.88N 2a: 7.85N 3a: 9.81N 3.23N O.F. 1.47N type 3 A 125 V AC 2 A 30 V DC O.F. 0.74N type 1 A 125 V AC 1 A 30 V DC <Ag contact> 0.5 A 30 V DC <Au contact> 0.1 A 30 V DC <Standard> 10.1 A 250 V AC <High capacity> 16 A 250 V AC (EOL)* *Product is end of life 16 A 380 V AC (EOL)* *Product is end of life (High capacity load contact: 1a) 5 A 250 V AC 6 A 30 V DC (Low-level circuit load contact: 1a) 0.1 A 125 V AC 10 ma 8 V DC Au clad contact 5 ma 6 V DC 2 ma 12 V DC 1 ma 24 V DC 5 ma 6 V DC 2 ma 12 V DC 1 ma 24 V DC (Au type: ) (O.F N) (O.F N) (Standard) Silver alloy (Low-level) Gold-clad silver alloy (Standard) Silver alloy (Low-level) Gold plating Silver alloy Silver alloy Silver alloy UL/CSA UL/CSA/VDE/TÜV/ SEMKO UL/CSA/VDE/TÜV/ SEMKO UL/CSA/TÜV/SEMKO

9 Switch Selector Chart Detection Switch FT-2way SW FT-µ SW FT SW FP Type of switch NEW NEW (Addition of Long stroke type) Features Detect laterally in two directions with a single switch Ultra compact and slim for space saving Supports low level loads with twin gold plate contacts ABC3 ABC2 ABC1 ABP8 World s smallest Ultra-low profile 1.4 mm.055 inch Original coil mechanism serves a high contact reliability and wiping effect Horizontal and vertical mounting types are available and detecting from horizontal and vertical directions is possible High overtravel (1.3 mm.051 inch) makes it easy for installation. (Long stroke type) Ultra-low profile 1.4 mm.055 inch The unique coil springactivated mechanism yields a light operating force and a high overtravel to faciliate installation Detecting from vertical and horizontal direction is possible Ultra-miniature size Low operating force High contact reliability in a low-level load by sliding crossbar contacts O.F. by pin plunger (gf, Max.) 0.3N 0.3N 0.3N 0.3N Max. contact rating (resistive) 5 µa to 10 ma 5 V DC 0.01 ma 5 V DC to 10 ma 5 V DC 0.01 ma 5 V DC to 10 ma 5 V DC 0.01 ma 5 V DC to 100 ma 10 V DC Rating of low-level circuit type (resistive) Expected life (min. ope.) Electrical 10 5 (5 ma 5 V DC to 10 ma 5 V DC) 10 5 (0.01 ma 5 V DC to 10 ma 5 V DC) 10 5 (0.01 ma 5 V DC to 10 ma 5 V DC) (0.1 A 10 V DC) 10 5 (0.1 ma 5 V DC) Mechanical Quickconnect Solder Terminal style Screw PC board SMD SMD SMD Lead wire Connector Contact material Gold-clad Gold-clad Gold-clad Gold-clad UL, CSA,VDE, SEMKO Page

10 Detection Switch Unit: Unit: New FD Tip SW ABU8 AHF2 Low operating force Max. Photo sensor inside 0.34N oz The contact type is High contact reliability in a equivalent to normally low-level load by sliding closed contacts, which crossbar contacts satisfies the PL Act. Reflow soldering available 0.34N Operation angle: 25 to 60 degrees 3 ma 6 V DC to 100 ma 30 V DC Photo transistor Please refer to the inside of catalog (0.1 A 30 V DC) 10 5 (1 ma 5 V DC) Gold-clad Silver alloy

11 TECHNICAL TERMINOLOGY & CAUTIONS FOR USE TECHNICAL TERMINOLOGY & CAUTIONS FOR USE TECHNICAL TERMINOLOGY 1. Rated values Values indicating the characteristics and performance guarantee standards of the snap-action switches. The rated current and rated voltage, for instance, assume specific conditions (type of load, current, voltage, frequency, etc.). 2. Mechanical life The service life when operated at a preset operating frequency without passing electricity through the contacts. (The life test is performed at a switching frequency of 60 times/minute and operating speed of 100 mm/second at the regular cam.) 3. Electrical life The service life when the rated load is connected to the contact and switching operations are performed. (The life test is performed at a switching frequency of 20 times/minute and operating speed of 100 mm/second at the regular cam.) 4. Contact form This refers to the components determining the type of application which make up the electrical input/output circuits in the contact. Switching type Normally closed type Normally open type COM COM COM Terminal symbols COM: Common terminal NC: Normally closed terminal NO: Normally open terminal 5. Insulation resistance Resistance between noncontinuous terminals, terminals and metal parts not carrying current, and between terminals NC NO NC NO and the ground. 6. Withstand voltage Threshold limit value that a high voltage can be applied to a predetermined measuring location for one minute without causing damage to the insulation. 7. Contact resistance This indicates the electrical resistance at the contact part. Generally, this resistance includes the conductor resistance of the spring and terminal portions. 8. Vibration resistance Malfunction vibration... Vibration range where a closed contact does not open for longer than a specified time due to vibrations during use of the snap-action switches. 9. Shock resistance Shock durability... Shock range where the mechanical shocks received during snap-action switches transport and installation do not damage the parts or harm the operating characteristics. Malfunction shock... Shock range where a closed contact does not open for longer than a specified time due to shocks during use of the snap-action switches. 10. Operating Force (O.F.) The force required to cause contact snap-action. It is expressed terms of force applied to the plunger or the actuator. 11. Release Force (R.F.) The force to be applied to the plunger or the actuator at the moment contact snaps back from operated position to unoperated position. 12. Pretravel (P.T.) Distance of the plunger or the actuator movement from free position to operating position. 13. Overtravel (O.T.) The distance which the plunger or the actuator is permitted to travel after actuation without any damage to the switching mechanism. 14. Movement Differential (M.D.) The distance from operating to release position of the plunger or the actuator. 15. Operating Position (O.P.) The position of the plunger or the actuator when the traveling contacts snaps with the fixed contact. 16. Free Position (F.P.) Position of the switch plunger or the actuator when no force is applied to. 17. Overtravel Position (O.T.P.) The stopping position of the plunger or the actuator after total travel. 18. Release Position (R.P.) The position of the plunger or the actuator when the traveling contact snaps back from operating position to its original position. The following terminologies are applied to all our switches. F.P. P.T. O.P. O.F. O.T. T T.P. T.F. M.D. R.P. R.F. Center of mounting holes T.T. CAUTIONS FOR USE Technical Notes on Mechanical Characteristics 1. Actuation Force and Stroke may cause actuator damage due to Adequate stroke setting is the key to high inertia of the drive mechanism. It is reliability. It is also important that advisable that the stroke be adjusted with adequate contact force be maintained to the mounting plate or driving mechanism. ensure high reliability. For a normally The figure at right shows a typical closed circuit, the driving mechanism example of activation and contact forces should be set so that the actuator is varying with stroke. In the vicinity of the normally in the free position. For a O.P. and R.P., the contact force is normally open circuit, the actuator should diminished, causing chatter and contact be pressed to 70% to 100% of the bounce immediately before or after specified stroke to absorb possible reversal. For this reason, use the switch errors. while giving due consideration to this. If the stroke is set too close to the This also causes the snap action switch operating point (O.P.), this may cause to be sensitive to vibration or physical unstable contact, and in the worst case impact. 10 Contact force Operating force OF RF NC On FP On reversal On reversal On OTP NO FP RP OP TTP PT MD OT Stroke Stroke

12 2. Changes in Operation Characteristics Exercise design care so that malfunctions will not occur if the snap action switch characteristics vary by as much as 20% from, rated values. 3. Mechanical Conditions for Type Selection Actuator type should be selected according to activation method, activation TECHNICAL TERMINOLOGY & CAUTIONS FOR USE speed, activation rate, and activation frequency. 1) An extremely slow activation speed may cause unstable contact transfer, possibly resulting in contact failures or contact fusion. 2) An extremely high activation speed may cause damage to contacts or contact response failure. 4. Driving Mechanism Use of a driving mechanism which will cause physical impact to the actuator should be avoided. <Example> Bad Good Technical Notes on Electrical Characteristics 1. The snap-action switch is designed for AC operations. While it has small contact gaps and no arc absorber, it may be used for low-capacity DC operations. (However, a DC magnetic blow-out switch is available in the NZ Basic Switches.) 2. For applications with very small switching voltage or current, choose the dry circuit type. Small current and voltage Application Range (Dry Circuit type) Current (ma) Application to Electronic Circuits 1) The snap-action switch contacts can sustain bounce or chatter when closed. Bounce or chatter can cause noise or pulse count errors when the snap action switch is used in electronic circuits. 2) If contact bounce or chatter poses problems in the vicinity of the O.P. and R.P., use a suitable absorption network, such as a C/R network. 4. Check the surge current, normal current and surge duration. 5. Contact resistance given in performance specifications is measured with a voltage drop method using 6 to 8 V DC, 1 A (except for low-level load type). Contact resistance across COM and NC terminals is measured in the open position, while contact resistance across COM and NO terminals is measured in the closed position. 6. Ratings are measured under the following conditions: Inductive load: Power factor = 0.6 to 0.7 Time constant = 7 ms or less (DC) 7. To prevent contact fusion failure, be sure to use a serial resistance for each capacitive load. 8. If snap action switch operation is synchronized with the AC supply phase, this may cause: shortened electrical life, contact fusion failure, contact transfer, or other reliability problems DC voltage (VDC) Cautions in a circuit 1. Contact protection is recommended when snap-action switches are used in an inductive load circuit. (except for NZ Basic Switches magnetic blow-out types for DC) Circuit diagram r c R r c R Notes 1. r = more than 10 ohms 2. In an AC circuit. Impedance of L is to be slightly smaller than impedance of r and c. Can be used for both AC and DC circuits. Impedance of r is nearly equal to impedance of L. C: 0.1 µf 2. Do not connect the contacts on individual switches to different type or different poles of the power supply. Examples of power supply connections (connection to different poles) Wrong Solenoid load Right Lamp load PL Lamp load PL Solenoid load Load connected to same pole Example of wrong power supply connection (connection to different poles of power supply) This may lead to mixed DC and AC. Wrong 3. Avoid circuits which apply voltage between contacts. (This may lead to mixed deposition.) Wrong AC DC Load L Load L diode R For DC circuits only. L 200V ZNR Varistor R Can be used for both AC and DC circuits. 100V 11

13 TECHNICAL TERMINOLOGY & CAUTIONS FOR USE Mounting state and environment 1. Checking the insulation distance After mounting and wiring, check the insulation distance between terminals and the ground. If the insulation distance is inadequate, mount insulating material between as required. 2. Fastening the microswitch body See the Section NOTES for the individual switch. 3. Position adjustment with effector The effector should be positioned so that direct force is not applied to the pushbutton or actuator in its free position. The operating force to the pushbutton should only be applied in a perpendicular direction. 4. Soldering precautions 1) For manual soldering, lay the terminals flat (horizontal with the ground) and quickly perform the soldering operation using a soldering iron with the appropriate heat capacity and the proper amount of solder. Take care that the flux does not flow into the switch interior by using a ventilation fan to discharge flux gas and to prevent contact of the switch body with the soldering iron tip. Be careful not to apply force to the lead wires or the terminal portions immediately after soldering. The temperature setting and time conditions vary depending on the product. See the Section NOTES for each product. 2) For automatic soldering also, see the Section NOTES for each product. <Examples> Wrong Soldering iron tip Correct 5. Avoid using in a silicon atmosphere Avoid using organic silicon rubber, adhesives, sealing compounds, oil, grease, and wires in a silicon atmosphere. 6. Please consult us when using under the following conditions: 1) Environments where hydrogen sulfide or other corrosive gases are present. 2) Environments where gasoline, thinner or other flammable, explosive gases are present. 3) Dusty environments (for non-seal type snap action switches). 4) The perpendicular operating speed exceeds the allowable operating speed. 5) Switching between different poles. 6) Use in environments not in the prescribed temperature or humidity range. 7. Storage precautions To prevent discoloration due to sulfurization of the terminals (silverplated), store the switches in a polyethylene bag or other suitable airtight container. 8. Usage, storage, and transport conditions 1) During usage, storage, or transportation, avoid locations subject to direct sunlight and maintain normal temperature, humidity, and pressure conditions. The allowable specifications for environments suitable for usage, storage, and transportation are given below. Temperature: The allowable temperature range differs for each switch, so refer to the switch s individual specifications. In addition, when transporting or storing switches while they are tube packaged, there are cases when the temperature may differ from the allowable range. In this situation, be sure to consult the individual specifications. Humidity: 5 to 85% R.H. ; ;;;;; 85 Humidity, %R.H. Tolerance range (Avoid freezing when (Avoid used at temperatures condensation when lower than 0 C 32 F) used at temperatures higher than 0 C 32 F) Temperature, C F ;;;;;;;;;; ;;;;;;;;;;; ;;;;;;;;;;; ;;;;;;;;;; Pressure: 86 to 106 kpa The humidity range varies with the temperature. Use within the range indicated in the graph below. 2) Condensation Condensation forms when there is a sudden change in temperature under high temperature, high humidity conditions Condensation will cause deterioration of the switch insulation. 3) Freezing Condensation or other moisture may freeze on the switch when the temperatures is lower than 0 C 32 F. This causes problems such as sticking of movable parts or operational time lags. 4) Low temperature, low humidity environments The plastic becomes brittle if the switch is exposed to a low temperature, low humidity environment for long periods of time. 5) Storage for extended periods of time (including transportation periods) at high temperatures or high humidity levels or in atmospheres with organic gases or sulfide gases may cause a sulfide film or oxide film to form on the surfaces of the contacts and/or it may interfere with the functions. Check out the atmosphere in which the units are to be stored and transported. 6) In terms of the packing format used, make every effort to keep the effects of moisture, organic gases and sulfide gases to the absolute minimum. 9. We reserve the right to modify without notice the materials, internal components, and other parts to improve product quality. 10. Handling precautions When handling the switches, be careful not to drop them on the floor since this may damage them. For items 5. and 6., select contact sulfurization (clipping) prevention products (FS and Au clad 2-layer contacts) for use with extremely small loads or an environment-resistant Turquoise switch ) Failure modes of switches include short-circuiting, open-circuiting and temperature rises. If this switch is to be used in equipment where safety is a prime consideration, examine the possible effects of these failures on the equipment concerned, and ensure safety by providing protection circuits or protection devices. In terms of the systems involved, make provision for redundancy in the design and take steps to achieve safety design. 2) The ambient operating temperature (and humidity) range quoted is the range in which the switch can be operated on a continuous basis: it does not mean that using the switch within the rating guarantees the durability performance and environment withstanding performance of the switch. For details on the performance guarantee, check the specifications of each product concerned. 12

14 Types of actuators Shape Class. TECHNICAL TERMINOLOGY & CAUTIONS FOR USE Pretravel (P.T.) Overtravel (O. T.) Operating Force (O. F.) Vibration Shock Features Pin plunger Small Small Large Outstanding Appropriate for linear short-stroke action. Pin plunger acts directly on snap action mechanism, enabling high-precision positioning. Amount of movement after operation is smallest among all of the actuators, however, so reliable stopper is required. Spring small plunger Small Medium Large Excellent Used in much the same way as the pin plunger, but is easier to use because the amount of movement after operation is larger. Spring short plunger Small Medium Large Good Pin plunger is short, with large plunger diameter that makes centering easier. Like small spring plunger, amount of movement after operation is large. Panel attachment plunger Small Large Large Good Secured to panel with hex or lock nut; used as manual or mechanical plunger. Amount of movement after operation is extremely large and operation point can be adjusted by changing attachment position. Can be used in combination with low-speed cam. Panel attachment roller plunger Small Large Large Possible This is the panel attachment type with a roller, and can be used with fastmoving cams and dogs.. Hinge lever Large Medium Small Possible Little force required for operation. Appropriate for use with low-speed cams and dogs; has large stroke. Lever available in various shapes to fit operating unit. Simulated roller lever Large Medium Small Possible Tip of hinge lever is bent into a semi-circle, enabling use as a simple roller type. Leaf lever Large Large Small Excellent Play in lever is used to assure maximum stroke. Construction provides for space where lever is attached, for outstanding resistance to freezing. Hinge roller lever Large Medium Small Possible This is a hinge lever with a roller, and can be used with high-speed cams and dogs. The force required for pin plunger action is lighter than that of the lever, and the stroke is longer. One way action hinge roller lever Medium Medium Medium Possible This is hinge roller lever type, and can operate in relation to an operating unit from a one way direction, but the roller is bent from the opposite direction and cannot move. This can be used to prevent reverse-direction action. Leaf spring Medium Medium Medium Good This has a leaf spring with offset yield force and has a large stroke. Ideal for driving low-speed cams and cylinders. Fulcrum is fixed for high precision. To prevent leaf damage, movement after operation must be within specified value. Roller leaf spring Medium Medium Medium Good This is a leaf spring with a roller, and can be used with high-speed cams. (O.C. reversed action groove type) Reverse-action hinge lever (O.C. reversed action groove type) Reverse-action hinge roller lever (O.C. reversed action groove type) Reverse-action hinge roller short lever Large Small Medium Excellent Medium Medium Medium Excellent Small Medium Large Excellent This is used for low-speed, low-torque cams. The lever comes in various shapes to fit the operating body. This is a reverse-action hinge lever with a roller and is appropriate for cam operation. Excellent resistance to vibration and impact when not engaged. This is a shorter version of the reverse-action hinge lever with a roller and has a larger action force, but is appropriate for cam operation with a short stroke. Excellent resistance to vibration and impact when not engaged. The plunger is constantly pressed down by a coiled spring, and operating the lever induces reverse action. Because the plunger is depressed when not engaged, vibration and shock resistance are excellent. Pressing the plunger too far does not cause abnormal force to be applied to the switch mechanism, so a stable service life is assured. Rotating-action type Large Large Small Possible This is a rotating, light-action type that is ideal for detecting paper, coins, and similar objects. 13

15 TURQUOISE SWITCHES TURQUOISE SWITCHES High Environmental Resistance Turquoise Colored Seal Switches Against dust, gas and water Elastomer double molding technology, an industry first, and ultrasonic swaging technology contribute to uniform sealing in high production quantities IP67 type (immersion protected) Broad lineup: J, S and V models make up over 1,000 types. J type S type V type Lineup Terminal Actuator Size J type S type V type Type Solder PC board Straight Angle.110 quick-connect.187 quick-connect Wire leads Contact Pin plunger Hinge lever Short hinge lever Long hinge lever Simulated roller lever Roller lever Short roller lever Leaf lever Available Mounting hole Terminals Au, Ag M1.2, Wire leads Au, Ag M2.3, M3 Terminals Au, Ag Wire leads Au, Ag Terminals Au, Ag Wire leads Au, Ag M2.3 M3 Ultrasonic swaging process The rubber cap is securely sealed to the switch cover during an ultrasonic swaging process. Cross section of the rubber cap Cover Rubber cap Cover Rubber cap Protective grade of body: IP67 Dust and immersion protected type Rubber cap Cover Body Ultrasonic swaging process: A process which bends the material through ultrasonic vibration. Cross section of wire leads type Conforming to IP67 Common for dust protected and immersion protected type Rubber cap Elastomer double molding Elastomer double molding Elastomer: Elastic thermoplastic resin Epoxy resin (internal) Terminal position conforming to IP67 Wire leads Elastomer double molding The industry's first elastomer double molding technology is used to mold the elastomer to the switch body. A reliable seal of the body and cover is achieved. Construction The dust protected type (IP50) and the immersion protected type (IP67) pass the following tests, respectively. The immersion protected type is especially tested to check for the entry of water after soaking for a certain period of time. Avoid operation where they are immersed in water. 14 [Test conditions] Dust protected type (IP50) The powder circulation pump may be replaced by other means suitable to maintain the talcum powder in suspension in a closed test chamber. The talcum powder used shall be able to pass through a square- meshed sieve the nominal wire diameter of which is 50 µm and the nominal width between wires 75 µm. The amount of talcum powder to be used is 2 kg per cubic metre of the test chamber volume. The duration of the test is 8 hours. Immersion protected type (IP67) The lowest point of enclosures should be least 1,000 mm below the surface of the water. The duration of the test is 30 minutes.

16 NOTES FOR TURQUOISE SWITCHES TURQUOISE SWITCHES IMPORTANT NOTES REGARDING USE 1. Fastening of the switch body Fasten the switch body onto a smooth surface using the correct screw as shown in the chart below and tighten it with the prescribed torque. Be careful not to exceed the prescribed torque when tightening as this may adversely affect the sealing properties and switch functioning, and also cause damage. If using a torque driver, verify that it is set to the prescribed torque. Also, we recommend that you use a spring washer and adhesive to prevent loosening and to lessen the tightening load on the switch. Screws Tightening torque M1.2 Not more than 0.098N m ABJ M2.3 Not more than 0.29N m M3.0 Not more than 0.29N m ABS M2.3 Not more than 0.29N m ABV M3.0 Not more than 0.49N m 2) Fixed pin type To secure the switch unit, thermally crimp or press-fit the mounting pins. If the pins are to be press-fitted, install a guide on the opposite surface to the mounting pins to prevent them from slipping out of position and developing play. 3) Be sure to maintain adequate insulating clearance between each terminal and ground. 4) The positioning of the switch should be such that direct force is not applied to the pushbutton or actuator in its free position. The operating force to the pushbutton should only be applied in a perpendicular direction. 5) The standard value of overtravel used should be within the range of 70% to 100% of the rated O.T. value. 6) When soldering the V-type turquoise switch or the immersion protected type of the J and S type switches, the sealing material sometimes forms a lump or bulge at the base of the terminal or lead. Be sure to allow enough space for this when attaching the switch. 2. Soldering operations 1) Manual soldering: use soldering irons (max. 350 C 662 F) capable of temperature adjustment. This is to prevent deterioration due to soldering heat. Care should be taken not to apply force to the terminals during soldering. Specifications Wattage Soldering time ABJ 18 W Within 3 seconds ABS 60 W Within 3 seconds ABV 60 W Within 5 seconds 2) Terminal portions should not be moved within 1 minute after soldering. 3. Variance of operating characteristics Allow for up to ±20% variation of the specified characteristics values to compensate for long term operational wear of the switch in your design. 4. Cautions regarding use 1) When switching inductive loads (relays, solenoids, buzzers, etc.), an arc absorbing circuit is recommended to protect the contacts. 2) If switching of the contact is synchronized with the phase of the AC power, reduced electrical life or welded contact may occur. Therefore, test the switch while it is operating under actual loads for this condition. If found, you may wish to take corrective action in your design. 3) In the following operating condition, the electrical life might be greatly reduced depending upon the switching load. Please consult us before use. Switching operation at a high or low speed (near limits specified). 4) If the build up of dust or dirt becomes so severe that it requires the use of the attached lever, there is the concern that the flexible part may be impeded and return movement may not be possible. In this situation take the following precautions: Select a product number for a switch with a higher operation load or use a leaf type lever. Attach a protective cover to the lever. 5) If the leaf lever type switch is excessively pushed (pushed further than the operational limit position) or switching is done at high speed or is accompanied by the impact, the lever will break. Please be careful. Also, be careful with the BV short roller lever type switch as improper return may result from pressing too much. 5. Protection from dust, water and corrosive gas 1) The pin button and the space around the body cap Turquoise switches are sealed with elastic material, the terminal portion is integrally molded. This prevents dust entry and protects the switch against corrosive gases. Wireleaded types are recommended for applications subject to water or oil splash. However, avoid soaking these immersion protected types in oil or water, because they types are not of completely oil tight construction. 2) Take care that breathing actions don t allow water vapor to get inside during opening and closing or cause rapid temperature changes. 3) Keep away from environments where silicon based adhesives, oil or grease are present as faulty contacts may result from silicon oxide. Do not use in areas where flammable or explosive gases from gasoline and thinner, etc., may be present. Dust protection test Test conditions: Dust-protected switches... Repeatedly pass pure talc powder through a standard wire sieve with a 75mm nominal diameter so that the talc is suspended in the air around the switch area. Two kilograms of talc powder should be suspended for each cubic meter of laboratory space. The talc suspension should then be left for eight hours. Contact resistance Waterproof test Test conditions: Immersion protected IP67 switches... Submerge at 1 m below the water surface for 30 minutes. Insulation resistance (MΩ) 1Ω 100mΩ 10mΩ Standard value 8 hours Elapsed time (h) Hydrogen sulfide exposure test Test conditions: Concentration: 3 ppm Temperature: 40 C 104 F Humidity: 75% RH Contact resistance Ω 10Ω 1Ω 100mΩ 10mΩ Standard value 30 minutes Typical products Elapsed time (h) Elapsed time (h) Turquoise switches 6. Oil-proof and chemical-proof characteristics The rubber elastomer swells when exposed to oil and chemicals. The extent of swelling will vary widely depending on the type and amount of oil and chemicals. Check with the actual oil or chemicals used. In particular, be aware that solvents such as freon, chlorine, and toluene cannot be used. 15

17 NOTES FOR TURQUOISE SWITCHES 7. Washability (ABJ and ABS) The Turquoise switch terminal with lead wires type and without lead wires typeshare the same main body. As a result, if the print board terminal type satisfies the set conditions, then it can undergo a complete cleaning after automatic soldering. After soldering is completed, perform cleaning within the prescribed temperature and time range, and pay careful attention to the following points. 1) Perform proper temperature, time, drying control in the cleaning process in order to prevent absorption of the liquid due to respiratory action. Be particularly careful that all the water droplets in the switch area are cleaned off in the final drying process. 2) Some cleaning liquids (solvents) may harm the rubber parts. Use water or a weak alkaline water solution. 3) Ultrasonic cleaning methods may damage the internal components or contacts. Use immersion or shower cleaning methods. In addition to the above points, the use of automatic cleaning equipment is particularly recommended for easy control of the process temperature and time.the recommended cleaning conditions for the Turquoise switches are shown below. However, please evaluate the actual cleaning process to verify its suitability for the switch. Recommended Cleaning Method Cleaning Water or weak alkaline water solution 70 deg.c 3 minutes max. Room temperature 1 minute max. Rinse Water Room temperature 1 minute 70 deg.c max. 3 minutes max. Drying 90 deg.c 3 minutes min. (until the water droplets around the switch area are gone) REFERENCE 1. Dust-protected type This type of construction prevents dust that is large enough to have an effect on operation from getting inside the unit. This construction is stipulated by protective classes against solid matter in the IEC standards (IEC529). Test conditions: The switch is left for eight hours in a test chamber with a constant level of floating pure talc that has passed through a standard 75mm sieve, in a concentration of 2kg of talc per cubic meter of volume in the test chamber. 2. Immersion-protected type This type of construction prevents any harmful effects even after the device is left underwater at a depth of one meter for thirty minutes. This construction is stipulated by protective classes against water in the IEC standards (IEC529). 3. IEC s IP Codes The IEC (International Electrotechnical Commission) has defined the IP characteristic code that represents the levels of protection described in IEC standard 529. The two numbers that follow the IP code (the characteristics numbers) indicate the suitability of this protection for all environmental conditions. 1st characteristics number 2nd characteristics number IP Level of Protection Indicated by the 1st Characteristics Number 1st Characteristics Number Protection level (IEC529/Solid matter) 0 No protection Protected against solid 1 matter larger than 50mm Protected against solid 2 matter larger than 12mm Protected against solid 3 matter larger than 2.5mm Protected against solid 4 matter larger than 1.0mm Dust-protected type Prevents dust that is large 5 enough to have an effect on operation from getting inside the unit Dust-resistant type 6 Prevents dust from getting inside the unit Level of Protection Indicated by the 2nd Characteristics Number JIS C0920 Dropletprotected type I Dropletprotected type II Rainprotected type Splashprotected type Sprayprotected type Waterresistant type Immersionprotected type Underwater type 2nd Characteristics Number Protection level (IEC529/Liquid matter) 0 No protection Protected against water droplets that 1 fall perpendicular to the unit Protected against water droplets that 2 fall from within 15 of perpendicular to the unit Protected against water droplets that 3 fall from within 60 of perpendicular to the unit Protected against water that splashes 4 on the unit from any direction Free from adverse effects even if 5 sprayed directly with water from any direction Protected against water sprayed 6 directly on the unit from any direction Water does not get inside of the unit when submerged in 7 water according to the specified conditions Unit can be used 8 underwater Note: Details of test conditions are the same as JIS C Please refer to them. 16

18 NEW ULTRA-LONG STROKE, HIGH CONTACT RELIABILITY SEAL SWITCHES (SAME SIZE AS J TYPE) FEATURES 1. Same size as J type with ultra-long stroke. For pin plunger type, it maintains an ultra-long stroke O.T. (Over Travel) with over 2.2 mm on the NO side and over 2.5 mm on the NC side. Variations in operation can be absorbed. 2. Since contact pressure does not depend on the operation stroke, the range of possible use over the entire stroke is greatly increased. (Please refer to operation concept diagram.) 3. High contact reliability to support low level switching loads High contact reliability is maintained with gold plating on both sides of sliding contact. 4. Highly effective sealing for resistance against adverse environments Immersion protection type JIS C0920 (water-resistance experiments for electrical machines and protection rating against incursion of solid substances) D2 JIS D0203 (method for testing moisture resistance and water resistance in automotive components) IP67 IEC529 (rating for outer shell protection) ASQ1 TURQUOISE STROKE SWITCHES 5. Silent operation With sliding contact construction there is no operation noise. 6. Direct operation possible from lateral direction with pin plunger (lever-less operation allows space savings) 7. Contains no harmful substances (mercury, lead, sexivalent chrome, cadmium) TYPICAL APPLICATIONS 1. Automobiles (detection of door opening and closing and shift lever position, etc.) 2. Household appliances (propane stoves, vacuum cleaners, air conditioners, and washing machines, etc.) ORDERING INFORMATION Ex. ASQ1 Type of switch ASQ1: Turquoise stroke switch Size of mounting hole 0: 3 mm.118 inch standard type 1: 3 mm.118 inch without boss type Terminal 2: Wire leads right side type (NC and NO type only) 3: Wire leads left side type (NC and NO type only) 4: Solder terminal 5: PC board terminal 6: Wire leads (bottom type) Contact form 1: SPDS 2: SPST-NC (wire lead type only) 3: SPST-NO (wire lead type only) Remark: Not every combination is available. Please refer to the following table, PRODUCT TYPES. Actuator 0: Pin plunger 7: Leaf lever 8: Simulated leaf lever 17

19 ASQ1 OPERATION CONCEPT DIAGRAM (reference) Contact form: terminal type Operation load TF OF Operation load 0 OP (NC) Standard (mounting boss and hole center diameter or standoff) NC side OT (NC) Intermediary OFF range Contact pressure 0 NO side Stroke OT (NO) TTP OP (NO) FP Range of possible use NC side NO side PRODUCT TYPES 1. Terminal type (Mounting hole: 3mm standard type/3mm without boss type) Actuator Operating force Max. Mounting hole: 3mm standard type Solder terminal Mounting hole: 3mm without boss type PC board terminal Pin plunger 1.5N ASQ10410 ASQ11510 Leaf lever 1.7N ASQ10417 ASQ11517 Simulated leaf lever 1.5N ASQ10418 ASQ Wire leads bottom type (Mounting hole: 3mm standard type) Actuator Operating force Max. Wire leads bottom type (Mounting hole: 3mm standard type) Switching type NC type NO type Pin plunger 1.5N ASQ10610 ASQ10620 ASQ10630 Leaf lever 1.7N ASQ10617 ASQ10627 ASQ10637 Simulated leaf lever 1.5N ASQ10618 ASQ10628 ASQ Wire leads side type (Mounting hole: 3mm standard type) Wire leads right side type Wire leads left side type Actuator Operating force Max. (Mounting hole: 3mm standard type) (Mounting hole: 3mm standard type) NC type NO type NC type NO type Pin plunger 1.5N ASQ10220 ASQ10230 ASQ10320 ASQ10330 Leaf lever 1.7N ASQ10227 ASQ10237 ASQ10327 ASQ10337 Simulated leaf lever 1.5N ASQ10228 ASQ10238 ASQ10328 ASQ10338 RATING 1. Rating 1 ma, 5 V DC to 100 ma, 30 V DC Note: Please consult us regarding 42 V DC rating. 2. Operation environment and conditions Item Specifications Ambient and storage temperature 40 C to +85 C 40 F to +185 F (no freezing and condensing) Allowable operating speed 30 to 500 mm/sec. Max. operating cycle rate 120 cpm Note: When switching at low and high speeds or under vibration, or in high-temperature, high-humidity environments, working life and performance may be reduced remarkably depending on the load capacity. Please consult us. 3. Electrical characteristics Withstand voltage (Initial) Insulation resistance (Initial) Contact resistance (Initial) Between non-continuous terminals: 600 Vrms, Between each terminal and other exposed metal parts: 1,500 Vrms, Between each terminal and ground: 1,500 Vrms (at detection current of 1 ma) Min. 100 MΩ (at 100 V DC insulation resistance meter) (Locations measured same as withstand voltage.) Max. 1 Ω (at contact resistance meter) 18

20 ASQ1 4. Characteristics Item Specifications Electrical 5 V DC 1 ma (resistive load) Min Switching frequency: 20 times/min. Conduction ratio: 1:1 switching 16 V DC 50 ma (resistive load) Min Pushbutton operation speed: 100 mm/s life 30 V DC 100 ma (resistive load) Min Pushbutton switching position: free position (FP) to operation limit position (TTP) Vibration resistance (malfunction vibration resistance) Shock resistance (malfunction shock resistance) Vibration resistance endurance Terminal strength Heat resistance Cold resistance Humidity resistance High-temperature, high-humidity resistance Thermal shock resistance Water resistance Single amplitude: 0.75 mm Amplitude of vibration: 10 to 55 Hz (4 minutes cycle) Direction and time: 30 minutes each in X, Y and Z directions Amplitude of vibration: 5 to 200 Hz (10 minutes cycle) Acceleration: 43.1 m/s 2 Direction and time: 30 minutes each in X, Y and Z directions Shock value: 980 m/s 2 Direction and time: 5 times each in X, Y and Z directions Frequency of vibration: 33.3 Hz, Acceleration: 43.1 m/s 2 Direction and time: 8 hours each in X, Y and Z directions 6 N min. (each direction) *Terminal deformation possible. 85 C 185 F 500 houres 40 C 40 F 500 houres 40 C 104 F 95% RH 500 houres 85 C 185 F 85% RH 500 houres 30 min. at 85 C 185 F to 30 min at 40 C 40 F for 1,000 cycles Submersed for 30 min. under 1 m of water. Notes: As long as there are no particular designations, the following conditions apply to the test environment. Ambient temperature: 5 to 35 C 41 to 95 F Relative humidity: 25 to 85% RH Air pressure: 86 to 106 kpa 5. Protective structure 1) JIS C0920: Waterproof type A concrete testing method is to check for any adverse effect on the structure after leaving it submerged for 30 minutes under 1 m ft of water (with temperature difference between water and switch no larger than 5 C 41 F). 2) IEC 529: IP67 (waterproof type) A concrete testing method is to check for any adverse effect on the structure after leaving it submerged for 30 minutes under 1 m ft of water (with temperature difference between water and switch no larger than 5 C 41 F). 3) JIS D0203: Equivalent of D2 A concrete testing method is to check for any adverse effect on the structure after leaving it submerged for 30 minutes under 10 cm inch of water (with temperature difference between water and switch no larger than 30 C 86 F). Note: Names of the standards can be found in the section describing features. 6. Operating characteristics Actuator Pin plunger Leaf lever Simulated leaf lever Operating Force (max. O.F.) * Note 2 1.5N 1.7N 1.5N Total travel Force (max. T.F.) (reference value) (2.0N) (3.1N) (2.8N) Free Position (max. F.P.) From mounting boss and hole center line 9.2mm.362inch 11.5mm.453inch 14.4mm.567inch From standoff 13.4mm.528inch 15.7mm.618inch 18.6mm.732inch Operating Position on NC side O.P. (N.C.) * Note 3 Operating Position on NO side O.P. (N.O.) * Note 4 From mounting boss and hole center line From standoff From mounting boss and hole center line From standoff 8.7±0.3mm.343±.012inch 12.9±0.3mm.508±.012inch 8.4±0.3mm.331±.012inch 12.6±0.3mm.496±.012inch Notes: 1. The above indicates the characteristics when operating the pushbutton from the vertical direction. 2. Indicates operation load for NO contact to achieve ON status. 3. Indicates position for NC contact to achieve OFF status. 4. Indicates position for NO contact to achieve ON status. 9.8±0.5mm.386±.020inch 14.0±0.5mm.551±.020inch 9.3±0.5mm.366±.020inch 13.5±0.5mm.531±.020inch 12.5±0.5mm.492±.020inch 16.7±0.5mm.657±.020inch 12.0±0.5mm.472±.020inch 16.2±0.5mm.638±.020inch Over travel on N.C. side (min. O.T. (N.C.)) 2.5mm.098inch 3.1mm.122inch 3.3mm.130inch Over travel on N.O. side (min. O.T. (N.O.)) 2.2mm.087inch 2.6mm.102inch 2.8mm.110inch Total Travel Position (T.T.P.) From mounting boss and hole center line (5.9mm.232inch) (6.2mm.244inch) (8.7mm.343inch) (reference value) From standoff (10.1mm.398inch) (10.4mm.409inch) (12.9mm.508inch) 19

21 ASQ1 DIMENSIONS General tolerance: ±0.25 ± Terminal type: Mounting hole 3mm, standard type Pin plunger FP MAX. OP (NC) 12.9± ±.012 OP (NO) 12.6± ±.012 TTP ( ) FP MAX. OP (NC) 8.7± ±.012 OP (NO) 8.4± ±.012 TTP ( ) C ± ± ± ± ± ± ± ± ± ± dia..075 dia. Operating Force (max. O.F.) 1.5N Free Position (max. F.P.) Operating Position on NC side O.P. (N.C.) Operating Position on NO side O.P. (N.O.) From mounting boss and hole center line From standoff From mounting boss and hole center line From standoff From mounting boss and hole center line From standoff Over travel on N.C. side (min. O.T. (N.C.)) Over travel on N.O. side (min. O.T. (N.O.)) 9.2mm.362inch 13.4mm.528inch 8.7±0.3mm.343±.012inch 12.9±0.3mm.508±.012inch 8.4±0.3mm.331±.012inch 12.6±0.3mm.496±.012inch 2.5mm.098inch 2.2mm.087inch dia dia ± ± ± ±.006 Leaf lever FP MAX. OP (NC) 14.0± ±.020 OP (NO) 13.5± ±.020 TTP ( ) FP MAX. OP (NC) 9.8± ±.020 OP (NO) 9.3± ±.020 TTP ( ) C ± ± dia..075 dia (18 ) 3.2± ± ± ± R ± ± ± ± Operating Force (max. O.F.) 1.7N Free Position (max. F.P.) Operating Position on NC side O.P. (N.C.) Operating Position on NO side O.P. (N.O.) From mounting boss and hole center line From standoff From mounting boss and hole center line From standoff From mounting boss and hole center line From standoff Over travel on N.C. side (min. O.T. (N.C.)) Over travel on N.O. side (min. O.T. (N.O.)) 11.5mm.453inch 15.7mm.618inch 9.8±0.5mm.386±.020inch 14.0±0.5mm.551±.020inch 9.3±0.5mm.366±.020inch 13.5±0.5mm.531±.020inch 3.1mm.122inch 2.6mm.102inch dia dia ± ± ± ± Note: When switching at high speed or under shock, lever endurance may drop. Therefore, please be sure to conduct an endurance evaluation under actual switching conditions. 20

22 ASQ1 Simulated leaf lever General tolerance: ±0.25 ±.010 FP MAX. OP (NC) 16.7± ±.020 OP (NO) 16.2± ±.020 TTP ( ) FP MAX. OP (NC) 12.5± ±.020 OP (NO) 12.0± ±.020 TTP ( ) R C ± ± dia..075 dia (18 ) 3.2± ± ± ± R ± ± ± ± Operating Force (max. O.F.) 1.5N Free Position (max. F.P.) Operating Position on NC side O.P. (N.C.) Operating Position on NO side O.P. (N.O.) From mounting boss and hole center line From standoff From mounting boss and hole center line From standoff From mounting boss and hole center line From standoff Over travel on N.C. side (min. O.T. (N.C.)) Over travel on N.O. side (min. O.T. (N.O.)) 14.4mm.567inch 18.6mm.732inch 12.5±0.5mm.492±.020inch 16.7±0.5mm.657±.020inch 12.0±0.5mm.472±.020inch 16.2±0.5mm.638±.020inch 3.3mm.130inch 2.8mm.110inch dia dia ± ± ± ± Note: When switching at high speed or under shock, lever endurance may drop. Therefore, please be sure to conduct an endurance evaluation under actual switching conditions. Mounting hole: 3 mm without boss type PC board terminal C ± ± ± ± PC board pattern dia. dia. 5.08± ± ± ±

23 ASQ1 2. Wire leads bottom type: Mounting hole 3mm, standard type General tolerance: ±0.25 ±.010 FP MAX. OP (NC) 8.7± ±.012 OP (NO) 8.4± ±.012 TTP ( ) C ± ± ± ± ± ± dia..075 dia dia dia ± ± R dia dia. 5.0±2.197± ± ± R Wire leads right side type: Mounting hole 3mm, standard type FP MAX. OP (NC) 8.7± ±.012 OP (NO) 8.4± ±.012 TTP ( ) C ± ± R ± ± ± ± dia..075 dia dia dia. 8.3± ± dia..055 dia. R R R ± ± ±2.197±

24 ASQ1 4. Wire leads left side type: Mounting hole 3mm, standard type General tolerance: ±0.25 ±.010 R dia..075 dia. 8.4± ± ± ±.006 FP MAX. OP (NC) 8.7± ±.012 OP (NO) 8.4± ±.012 TTP ( ) C ± ± R dia..055 dia. 8.3± ± ±2.197± ± ±.394 R dia dia..094 NOTES 1. Soldering conditions The application of excessive heat upon the switch when soldering can cause degradation of switch operation. Therefore, be sure to keep within the conditions given below. 1) Manual soldering: use soldering irons (max. 350 C 662 F, within 3 seconds) capable of temperature adjustment. This is to prevent deterioration due to soldering heat. Care should be taken not to apply force to the terminals during soldering. 2) Automatic soldering: Soldering must be done as below; 260 C 500 F: within 6 seconds 350 C 662 F: within 3 seconds 2. Mounting Please avoid use in which load would be applied to the sides (hatch part (both sides) shown below) of the switch in the direction indicated by the arrows. This could cause erroneous operation. Also, when using a metal installation board, please make considerations for burr direction designation and burr suppressing, etc., so that the burr side will not be on the switch installation side. 1) To secure the switch, please use an M3 small screw on a flat surface and tighten using a maximum torque of 0.29 N m. It is recommend that spring washers be used with the screws and adhesive be applied to lock the screws to prevent loosening of the screws. Please make sure not to apply adhesive onto the moving parts. 2) Be sure to maintain adequate insulating clearance between each terminal and ground. 3) Although it is possible to directly operate the pin plunger type from the lateral direction, please consult us if doing so. 4) After mounting please make sure no pulling load will be applied to the switch terminals. 5) Range of possible use: Please set the operation position to within the ranges in the following table so that there is sufficient insulation distance and to maintain contact reliability. Plunger/lever free Actuator From mounting boss and hole From standoff center line Pin plunger Leaf lever Simulated leaf lever Actuator Pin plunger Leaf lever Simulated leaf lever >9.2 >.362 >10.7 >.421 >13.5 >.531 >10.4 >.409 >14.9 >587 >17.7 >697 Plunger/Lever pushed From mounting boss and hole From standoff center line 7.8 to to to to to to to to to to to to Cautions regarding the circuit 1) In order to prevent malfunction in set devices caused by bounce and chattering during the ON-OFF switch operation, please verify the validity of the circuit under actual operating conditions and temperature range. 2) When switching inductive loads (relays, solenoids, buzzers, etc.), an arc absorbing circuit is recommended to protect the contacts. 4. Please verify under actual conditions. Please be sure to conduct quality verification under actual operating conditions in order to increase reliability during actual use. 5. Switch selection Please make your selection so that there will be no problems even if the operating characteristics vary up to ±20% from the standard values. 6. Oil-proof and chemical-proof characteristics The rubber cap swells when exposed to oil and chemicals. The extent of swelling will vary widely depending on the type and amount of oil and chemicals. Check with the actual oil or chemicals used. In particular, be aware that solvents such as freon, chlorine, and toluene cannot be used. 23

25 ASQ1 7. Environment Although continuous operation of the switch is possible within the range of ambient temperature (humidity), as the humidity range differs depending on the ambient temperature, the humidity range indicated below should be used. Continuous use near the limit of the range should be avoided. This humidity range does not guarantee permanent performance. ; ;;;;; Humidity, %R.H. 95 Acceptable range 50 (Avoid freezing when (Avoid used at temperatures condensation when lower than 0 C 32 F) used at temperatures higher than 0 C 32 F) Temperature, C F ;;;;;;;;;; ;;;;;;;;;;; ;;;;;;;;;;; ;;;;;;;;;; Other 1) Please remember that this switch cannot be used under water. Also, pleased be warned that switching and sudden temperature changes with the presence of water droplets can cause seepage into the unit. 2) Keep away from environments where silicon based adhesives, oil or grease are present as faulty contacts may result from silicon oxide. Do not use in areas where flammable or explosive gases from gasoline and thinner, etc., may be present. 3) When using the lever type, please be careful not to apply unreasonable load from the reverse or lateral directions of operation. 4) Do not exceed the total travel position (TTP) and press the actuator. This could cause operation failure. Also, when switching at high speed or under shock even within the operation limit, the working life may decrease. Therefore, please be sure to verify the quality under actual conditions of use. 5) Please make considerations so that the switch does not become the stopper for the moving part. 24

26 Dust protected type Immersion protected type (wire leads bottom type) (Mounting hole 2.3mm.091inch type) (Mounting hole 2.3mm.091inch type) HIGH ENVIRONMENTAL RESISTANCE ABJ1,2,3,4,5 TURQUOISE SWITCHES J TYPE (ABJ) FEATURES Ultra-miniature size ( mm) ( inch) Sealed construction for use in adverse environment-sealed construction by epoxy resin and rubber cap keeps off the cause of miscontact such as dust. Conforming to IP67* of IEC protective construction classification Elastomer double molding technology, an industry first and ultrasonic swaging technology contribute to uniform sealing in high production quantities UL/CSA approved Long stroke type is available Since the repeatability is excellent and the play distance (overtrabel) from the operating position is ample, the task of performing the adjustments during installation is an easy one. Operating position accuracy ±0.4 mm ±.016 inch Overtravel= Min. 2.0 mm.079 inch As wide range of high pressure is achieved, a stable reliability is ensured Leaf lever side wire leads type added. We now offer two types. M3 type installation hole Fixed pin type Immersion protected (wire leads side type) Long stroke type TYPICAL APPLICATIONS Industrial use video jack Automotives (ex. Device for opening and shutting of automobile doors) * Based on the protective construction classification of IEC, items which satisfy the test requirements are denoted with an IP designation. ORDERING INFORMATION Ex. ABJ Type of switch ABJ: Turquoise switch J type Size of mounting hole 1: 1.2 mm (.047 inch) 2: 2.3 mm (.091 inch) 3: 3 mm (.118 inch) 4: Fixed pin (right side pin) type 5: Fixed pin (left side pin) type Terminal 4: Solder terminal 5: PC board terminal 6: Wire leads (bottom type) 7: Wire leads (right side type) 8: Wire leads (left side type) Contact Actuator arrangement 1: SPDT 0: Pin plunger 2: SPST-NC 2: Hinge lever 3: SPST-NO 4: Simulated roller lever 6: Roller lever 8: Leaf lever (Mounting hole 3 mm.118 inch lead wire type only) L: Long stroke type Remarks: 1. Standard packing: Dust protected type 100 pcs./carton, 2,000 pcs./case; Immersion protected type 50 pcs./case. 2. SPST-NC and SPST-NO are only available for wire leads type. 3. Leaf lever is only available for wire leads type 4. Not every combination is available. Please refer to the following table, PRODUCT TYPES. Operating force by pin plunger (max.) 4: 1.23 N 6: 1.96 N 7: 2.45 N (Long stroke type only) Contact 0: Silver-alloy 1: Gold-clad 25

27 ABJ1,2,3,4,5 PRODUCT TYPES 1. Dust protected type (Terminal type) Mounting hole 1.2mm.047inch type / Mounting hole 2.3mm.091inch type Silver alloy Pin plunger Hinge lever Actuator Simulated roller lever Roller lever Operating force Max. Mounting hole 1.2 mm.047 inch type Mounting hole 2.3 mm.091 inch type Solder terminal PC board terminal Solder terminal 1.23 N ABJ ABJ ABJ N ABJ ABJ ABJ N ABJ ABJ ABJ N ABJ ABJ ABJ N ABJ ABJ ABJ N ABJ ABJ ABJ N ABJ ABJ ABJ N ABJ ABJ ABJ Gold-clad Actuator Pin plunger Hinge lever Simulated roller lever Roller lever Operating force Max. Mounting hole Mounting hole 1.2 mm.047 inch type 2.3 mm.091 inch type Solder terminal PC board terminal Solder terminal 1.23 N ABJ ABJ ABJ N ABJ ABJ ABJ N ABJ ABJ ABJ N ABJ ABJ ABJ N ABJ ABJ ABJ N ABJ ABJ ABJ N ABJ ABJ ABJ N ABJ ABJ ABJ (1). Immersion protected type (Bottom wire leads type) Mounting hole 1.2mm.047inch type Silver alloy Actuator Operating force Mounting hole 1.2 mm.047 inch type Max. SPDT SPST-NC SPST-NO Pin plunger 1.23 N ABJ ABJ ABJ N ABJ ABJ ABJ Hinge lever 0.39 N ABJ ABJ ABJ N ABJ ABJ ABJ Simulated roller lever 0.39 N ABJ ABJ ABJ N ABJ ABJ ABJ Roller lever 0.39 N ABJ ABJ ABJ N ABJ ABJ ABJ Mounting hole 2.3mm.091inch type Gold-clad Actuator Operating force Mounting hole 1.2 mm.047 inch type Max. SPDT SPST-NC SPST-NO Pin plunger 1.23 N ABJ ABJ ABJ N ABJ ABJ ABJ Hinge lever 0.39 N ABJ ABJ ABJ N ABJ ABJ ABJ Simulated roller lever 0.39 N ABJ ABJ ABJ N ABJ ABJ ABJ Roller lever 0.39 N ABJ ABJ ABJ N ABJ ABJ ABJ Remarks: When ordering UL/CSA approved types, please attach suffix 9 to the part number. 26

28 ABJ1,2,3,4,5 Mounting hole 2.3mm.091inch type Silver alloy Actuator Operating force Mounting hole 2.3 mm.091 inch type Max. SPDT SPST-NC SPST-NO Pin plunger 1.23 N ABJ ABJ ABJ N ABJ ABJ ABJ Hinge lever 0.39 N ABJ ABJ ABJ N ABJ ABJ ABJ Simulated roller lever 0.39 N ABJ ABJ ABJ N ABJ ABJ ABJ Roller lever 0.39 N ABJ ABJ ABJ N ABJ ABJ ABJ Gold-clad Pin plunger Hinge lever Mounting hole 3mm.118inch type (Leaf lever type) Silver alloy Operating force Mounting hole 3 mm type Actuator Max. SPDT SPST-NC SPST-NO 0.98 N ABJ ABJ ABJ Leaf lever 1.27 N ABJ ABJ ABJ Gold-clad 2-(2). Immersion protected type (Side wire leads type) Fixed pin (right side pin) type Silver alloy Operating force Wire leads type Actuator Wire leads direction Max. SPST-NC SPST-NO 1.27 N Right ABJ ABJ N Left ABJ Leaf lever 1.76 N Right ABJ ABJ N Left ABJ Gold-clad Actuator Simulated roller lever Roller lever Leaf lever Leaf lever Actuator Actuator Operating force Mounting hole 2.3 mm.091 inch type Max. SPDT SPST-NC SPST-NO 1.23 N ABJ ABJ ABJ N ABJ ABJ ABJ N ABJ ABJ ABJ N ABJ ABJ ABJ N ABJ ABJ ABJ N ABJ ABJ ABJ N ABJ ABJ ABJ N ABJ ABJ ABJ Operating force Mounting hole 3 mm type Max. SPDT SPST-NC SPST-NO 0.98 N ABJ ABJ ABJ N ABJ ABJ ABJ Operating force Wire leads type Wire leads direction Max. SPST-NC SPST-NO 1.27 N Right ABJ ABJ N Left ABJ N Right ABJ ABJ N Left ABJ Fixed pin (left side pin) type Silver alloy Operating force Wire leads type Actuator Wire leads direction Max. SPST-NC SPST-NO 1.27 N Right ABJ ABJ N Left ABJ Leaf lever 1.76 N Right ABJ ABJ N Left ABJ Remarks: When ordering UL/CSA approved types, please attach suffix 9 to the part number. 27

29 ABJ1,2,3,4,5 Gold-clad Leaf lever Mounting hole 3mm.118inch type Silver alloy Leaf lever Gold-clad Leaf lever Actuator Actuator Actuator Operating force Max. 3. Immersion protected type (Bottom wire leads type) Long stroke type Mounting hole 2.3mm.091inch type Silver alloy Operating force Mounting hole 2.3 mm type Actuator Max. SPDT SPST-NC SPST-NO Pin plunger (Horizontal) 2.45 N *ABJ261L70 ABJ262L70 ABJ263L70 Remarks: When ordering UL/CSA approved types, please attach suffix 9 to the part number. APPLICABLE CURRENT RANGE Wire leads direction SPST-NC Wire leads type SPST-NO 1.27 N Right ABJ ABJ N Left ABJ N Right ABJ ABJ N Left ABJ Operating force Wire leads type Wire leads direction Max. SPST-NC 1.27 N ABJ Left 1.76 N ABJ Operating force Wire leads type Wire leads direction Max. SPST-NC 1.27 N ABJ Left 1.76 N ABJ Gold-clad Operating force Mounting hole 2.3 mm type Actuator Max. SPDT SPST-NC SPST-NO Pin plunger (Horizontal) 2.45 N *ABJ261L71 ABJ262L71 ABJ263L71 Contact Applicable current range 1mA 0.1A 1A 2A Max. operating force for operation (at pin plunger) 1.23 N 1.96 N Ag Au SPECIFICATIONS 1. Contact rating Type Operating force Max. Standard rating Low-level circuit rating Silver alloy contact 1.76 N, 1.96 N 2 A 125 V AC 2 A 30 V DC 1.23 N, 1.27 N 1 A 125 V AC 1 A 30 V DC Long stroke type Silver alloy contact Gold-clad contact Long stroke type Gold-clad contact 2.45 N 1.23 N, 1.27 N 1.76 N, 1.96 N 2.45 N 1 A 125 V AC 1 A 30 V DC 0.1 A 125 V AC 0.1 A 125 V AC 0.1 A 30 V DC 5 ma 6 V DC 2 ma 12 V DC 1 ma 24 V DC 5 ma 6 V DC 2 ma 12 V DC 1 ma 24 V DC 28

30 ABJ1,2,3,4,5 2. Characteristics Mechanical life (O.T.: Specified value) Electrical life at rated load (O.T.: max.) Insulation resistance Leaf lever, Long stroke type Wire leads (right & left side type) Other types Silver alloy contact type Gold-clad contact type Dielectric strength Between non-continuous terminals Between each terminal and other exposed metal parts Between each terminal and ground Vibration resistance (Pin plunger type) Shock resistance (Pin plunger type) Contact resistance (Initial) Allowable operating speed (at no load) Max. operating cycle rate (at no load) Ambient temperature Unit weight Silver contact type Gold clad contact type Min (at 60 cpm) Min (at 60 cpm) Min (at 60 cpm) Min (at 20 cpm) Min (at 20 cpm) Min. 100 MΩ (at 500 V DC insulation resistance meter) 600 Vrms 1,500 Vrms 1,500 Vrms 10 to 55 Hz at single amplitude of 0.75 mm (Contact opening max. 1 msec.) Min. 294 m/s 2 {30 G} (Contact opening max. 1 msec.) Dust protected type (IP50): Max. 50 mω Immersion protected type (IP67): Max. 100 mω (By voltage drop 1 A 6 to 8 V DC) Dust protected type (IP50): Max. 100 mω Immersion protected type (IP67): Max. 150 mω (By voltage drop 0.1 A 6 to 8 V DC) 1 to 500 mm/sec. Other type: 120 cpm Long stroke type: 60 cpm 40 C to +85 C 40 F to +185 F Approx. 0.5 g.018 oz (IP50 type) 3. Operating characteristics Type of actuator Pin plunger Hinge lever Simulated roller lever Roller lever Leaf lever Operating force, Max. Release force, Min 1.23N 0.15N 1.96N 0.25N 0.39N 0.029N 0.64N 0.049N 0.39N 0.029N 0.64N 0.049N 0.39N 0.029N 0.64N 0.049N Pretravel, Max. Movement differential, Max. Overtravel, Min N 0.20N N 0.22N N 0.26N N 0.29N Operating position, Mounting hole: ± ±.008 Mounting hole: ± ±.008 Mounting hole: ± ±.039 Mounting hole: ± ±.039 Mounting hole: ± ±.039 Mounting hole: ± ±.039 Mounting hole: ± ±.039 Mounting hole: ± ±.039 Mounting hole: ± ±.079 Fixed pin type 10.7± ±.076 Mounting hole: ± ±.076 Fixed pin type 10.7± ±.076 Mounting hole: ± ±.076 Mounting hole: ± ±.079 Long stroke type 2.45N 0.20N ± ±.016 Note: The O.P. differs between the 1.2 mm and 2.3 mm dia. installation hole types. 29

31 ABJ1,2,3,4,5 DIMENSIONS General tolerance: ±0.25 ± Dust protected type 1-(1) PC board terminal Mounting hole 1.2 mm.047 inch type Pin plunger 5.4± ±.012 Pretravel 0.6Max..024Max 1.5 dia.059 dia 1.2±0.05 dia..047±.002 dia. 5.0± ±.006 Operating Position ± ± ± ± ± ± ± ± ± ± dia ± ± ± ± ± ± ± ± C C ± ±.005 t= ± ±.005 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from stand-off, 5.5± ±.088 7± ±.012 Hinge lever ± ±.016 R Pretravel 3.0Max..118Max ±0.05 dia..047±.002 dia Operating Position 6.8± ± ± ± ± ± ± ±.039 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from stand-off, 6.8± ± ± ±.047 Simulated roller lever R R ± ±.016 Pretravel 3.0Max..118Max ±0.05 dia..047±.002 dia. 5.08± ± ± ±.039 Operating Position 9.8± ± ± ±.047 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from stand-off, 9.8± ± ± ±.047 Roller lever Pretravel 3.0Max..118Max dia dia. R13.8 R dia..189 dia. Operating Position Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from stand-off, 13.1± ± ± ±

32 ABJ1,2,3,4,5 1-(2) Solder terminal General tolerance: ±0.25 ±.010 Pin plunger Mounting hole: 1.2 mm.047 inch Mounting hole: 2.3 mm.091 inch 5.4± ±.012 Pretravel 0.6Max..024Max 1.5 dia.059 dia 4.6± ±.012 Pretravel 0.6Max.024Max 1.5 dia.059 dia 5± ± Operating Position ± ± ± ± Operating Position 7± ± ± ± dia dia. 6.5± ± ± ± ± ± ± ± C C ± ± ± ± ± ± ± ±.006 dia dia Remarks: Dimensions of the actuator type are the same as corresponding PC board terminal types. 2. Immersion protected type 2-(1) Bottom wire leads type Pin plunger Mounting hole: 1.2 mm.047 inch Mounting hole: 2.3 mm.091 inch ± ± ± ±.394 5±2.197± Thickness of the lead wire: 0.3 mm 2 UL/CSA approved type: AWG #20 Color of the lead wire: COM...Black N.C....Red N.O....White COM N.O. N.C. 13.9± ± ± ±.394 5±2.197±.079 Thickness of the lead wire: 0.3 mm 2 UL/CSA approved type: AWG #20 Color of the lead wire: COM...Black N.C....Red N.O....White Remarks: 1. As for M1.2 type, other dimensions are the same as those of corresponding PC board terminal types. As for M2.3 type, other dimensions are the same as those of corresponding solder terminal types. 2. Dimensions of the actuator type are the same as corresponding PC board terminal types. 31

33 ABJ1,2,3,4,5 Leaf lever General tolerance: ±0.25 ±.010 Mounting hole: 3 mm.118 inch 13± ± ± ± ± ± Pretravel 6 max..236 max. R Free Position (19.0) (.748) Operating Position (16±2) (.630±.079) Totaltravel Position (11.5 min.) (.453) dia. dia R ± ± ± ±.394 5±2.197± Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, 16.0± ± (2) Side wire leads type Fixed pin type Right side pin type Right wire leads type ± ±.002 Free position (F.P.) max. Operating position (O.P.) 10.7 ± ±.028 Totaltravel position (T.T.P.) (8.55)(.337) R C ± ± ± ± ±0.05 dia..087 ±.002 dia. 2.6 ± ± ± ± ± ± ± ±.394 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, 10.7± ±

34 ABJ1,2,3,4,5 Left wire leads type General tolerance: ±0.25 ± ± ±.002 Free position (F.P.) max. Operating position (O.P.) 10.7 ± ±.028 Totaltravel position (T.T.P.) (8.55)(.337) 5 ±2.197 ± ± ±.394 R C ± ± ± ± ±0.05 dia..087 ±.002 dia. 2.6 ± ± ± ± Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, 10.7± ±.028 Left side pin type Right wire leads type C ± ± ±0.05 dia..087 ±.002 dia ± ± ± ± Free position (F.P.) max. Operating position (O.P.) 10.7 ± ±.028 Totaltravel position (T.T.P.) (8.55)(.337) R ± ± ± ± ± ± ± ±.394 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, 10.7± ±.028 Left wire leads type C ± ± ±0.05 dia..087 ±.002 dia ± ± ± ± Free position (F.P.) max. Operating position (O.P.) 10.7 ± ±.028 Totaltravel position (T.T.P.) (8.55)(.337) ±2.197 ± ± ±.394 R ± ± ± ± Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, 10.7± ±

35 ABJ1,2,3,4,5 Mounting hole 3mm.118 inch type General tolerance: ±0.25 ± dia dia Free position (F.P.) max. Operating position (O.P.) ± ±.028 Totaltravel position (T.T.P.) (14.1)(.555) R C ± ± ± ± ± ± ± ± ± ± Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, 16.25± ± Immersion protected type (Bottom wire leads type) Long stroke type Mounting hole: 2.3 mm.091 inch Free position (F.P.) max. Operating position (O.P.) 2.5 ± ± dia..079 dia dia dia ± ± C ± ± ± ± dia dia ± ± ±2.197 ±.079 COM NO NC 13.9 ± ±.016 Movement differential, Max Overtravel, Min Operating position 2.5 ± ±

36 ORDERING INFORMATION HIGH ENVIRONMENTAL RESISTANCE ABS1,4,5 VDE TURQUOISE SWITCHES S TYPE (ABS) FEATURES Subminiature size ( mm) ( inch) Sealed construction for use in adverse environment-sealed construction by epoxy resin and rubber cap keeps off the cause of miscontact such as dust. Conforming to IP67* of IEC protective construction classification Elastomer double molding technology, an industry first and ultrasonic swaging technology contribute to uniform sealing in high production quantities Expansion of low-level circuit type We offer an Au clad 2-ply contact type (for small loads) that we developed specifically for small current and voltage loads in the range of 1 ma to 100 ma and 5 V to 30 V. UL/CSA/VDE/SEMKO approved (AS for gold-clad twin layer, VDE and SEMKO are not approved.) * Based on the protective construction classification of IEC, items which satisfy the test requirements are denoted with an IP designation. TYPICAL APPLICATIONS Automotives Home appliances (vacuum cleaner, air purifier) Others (gas cookingrange, water vallet) Ex. ABS Type of switch ABS: Turquoise switch S type Wire and terminal position 1: Straight type 4: Right angle 5: Left angle Terminal 1:.110 quick-connect terminal 4: Solder terminal 5: PC board terminal 6: Wire leads Contact arrangement 1: SPDT 2: SPST-NC 3: SPST-NO Actuator 0: Pin plunger 1: Short hinge lever 2: Hinge lever 3: Long hinge lever 4: Simulated roller lever 6: Roller lever 8: Leaf lever Remarks: 1. Standard packing: Dust protected type 100 pcs./carton, 1,000 pcs./case; Immersion protected type 50 pcs./case. 2. SPST-NC and SPST-NO are only available for wire leads type. 3. Leaf lever is only available for wire leads type 4. As for wire position: Operating force by pin plunger (max.) 4: 0.98 N {100 gf} 5: 1.47 N {150 gf} Contact 0: Silver-alloy 1: Gold-clad triple layer 4: Gold-clad double layer Straight type Wire opposite to the actuator side type (Right angle) Wire actuator side type (Left angle) 5. Not every combination is available. Please refer to the following table, PRODUCT TYPES. 35

37 ABS1,4,5 PRODUCT TYPES 1. Dust protected type Silver alloy Pin plunger Actuator Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever Operating force Max..110 quick-connect terminal Solder terminal PC board terminal Terminal position Straight Right angle Left angle 0.98 N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS Gold-clad triple layer Actuator Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever.110 PC board terminal Operating force quick-connect Solder terminal Terminal position Max. terminal Straight Right angle Left angle 0.98 N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS Gold-clad double layer Pin plunger Actuator Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever.110 PC board terminal Operating force quick-connect Solder terminal Terminal position Max. terminal Straight Right angle Left angle 0.98 N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS N ABS ABS ABS ABS ABS Remarks: When ordering UL/CSA approved types, please attach suffix 9" to the part number. When ordering VDE/SEMKO approved types, please attach suffix 8" to the part number. 36

38 2. Immersion protected type (3 wire leads type SPDT) Silver alloy Pin plunger Actuator Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever Operating force Max. SPDT Wire position ABS1,4,5 Straight Right angle Left angle 0.98 N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS Gold-clad triple layer Actuator Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever SPDT Operating force Wire position Max. Straight Right angle Left angle 0.98 N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS Gold-clad double layer Pin plunger Actuator Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever SPDT Operating force Wire position Max. Straight Right angle Left angle 0.98 N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS Remarks: When ordering UL/CSA approved types, please attach suffix 9" to the part number. When ordering VDE/SEMKO approved types, please attach suffix 8" to the part number. 37

39 ABS1,4,5 3. Immersion protected type (2 wire leads type SPST-NC) Silver alloy Pin plunger Actuator Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever Operating force Max. SPST-NC Wire position Straight Right angle Left angle 0.98 N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS Gold-clad triple layer Actuator Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever SPST-NC Operating force Wire position Max. Straight Right angle Left angle 0.98 N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS Gold-clad double layer Pin plunger Actuator Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever SPST-NC Operating force Wire position Max. Straight Right angle Left angle 0.98 N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS Remarks: When ordering UL/CSA approved types, please attach suffix 9" to the part number. When ordering VDE/SEMKO approved types, please attach suffix 8" to the part number. 38

40 4. Immersion protected type (2 wire leads type SPST-NO) Silver alloy Pin plunger Actuator Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever Operating force Max. SPST-NO Wire position ABS1,4,5 Straight Right angle Left angle 0.98 N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS Gold-clad triple layer Actuator Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever SPST-NO Operating force Wire position Max. Straight Right angle Left angle 0.98 N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS Gold-clad double layer Pin plunger Actuator Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever SPST-NO Operating force Wire position Max. Straight Right angle Left angle 0.98 N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS N ABS ABS ABS Remarks: When ordering UL/CSA approved types, please attach suffix 9" to the part number. When ordering VDE/SEMKO approved types, please attach suffix 8" to the part number. 39

41 ABS1,4,5 5. Immersion protected type (3 wire leads type SPDT) Leaf lever type Silver alloy Leaf lever Actuator Operating force Max. SPDT Wire position Straight Right angle Left angle 0.88 N ABS ABS ABS N ABS ABS ABS Gold-clad triple layer Actuator Leaf lever Gold-clad double layer Actuator Leaf lever SPDT Operating force Wire position Max. Straight Right angle Left angle 0.88 N ABS ABS ABS N ABS ABS ABS SPDT Operating force Wire position Max. Straight Right angle Left angle 0.88 N ABS ABS ABS N ABS ABS ABS Immersion protected type (2 wire leads type SPST-NC) Leaf lever type Silver alloy SPST-NC Operating force Actuator Wire position Max. Straight Right angle Left angle 0.88 N ABS ABS ABS Leaf lever 1.08 N ABS ABS ABS Gold-clad triple layer Actuator Leaf lever Gold-clad double layer Actuator Leaf lever SPST-NC Operating force Wire position Max. Straight Right angle Left angle 0.88 N ABS ABS ABS N ABS ABS ABS SPST-NC Operating force Wire position Max. Straight Right angle Left angle 0.88 N ABS ABS ABS N ABS ABS ABS Immersion protected type (2 wire leads type SPST-NO) Leaf lever type Silver alloy SPST-NO Operating force Actuator Wire position Max. Straight Right angle Left angle 0.88 N ABS ABS ABS Leaf lever 1.08 N ABS ABS ABS Gold-clad triple layer Leaf lever Actuator SPST-NO Operating force Wire position Max. Straight Right angle Left angle 0.88 N ABS ABS ABS N ABS ABS ABS Remarks: When ordering UL/CSA approved types, please attach suffix 9" to the part number. When ordering VDE/SEMKO approved types, please attach suffix 8" to the part number. 40

42 Gold-clad double layer Leaf lever Actuator Operating force Max. gf Remarks: When ordering UL/CSA approved types, please attach suffix 9" to the part number. When ordering VDE/SEMKO approved types, please attach suffix 8" to the part number. SPST-NO Wire position ABS1,4,5 Straight Right angle Left angle 0.89 N ABS ABS ABS N ABS ABS ABS SPECIFICATIONS 1. Contact rating Voltage Silver alloy contact type Low-level circuit rating (Gold-clad contact type) Rated voltage Resistive load 6 V DC 5 ma 12 V DC 2 ma 24 V DC 1 ma Gold-clad contact type Gold-clad triple layer Resistive load Inductive load Resistive load Gold-clad twin layer 125 V AC 2 A 2 A 0.1 A 250 V AC 2 A 2 A 0.1 A 30 V DC 2 A 2 A 0.1 A 0.1 A 125 V DC 0.4 A 0.05 A Recommended contact material chart classified by load voltage & current 2A 100mA 1mA 0 DC AC 5 5 Silver-alloy Gold-clad triple layer Gold-clad double layer 15 30V V Remarks: If the contact is being used in the constant low-level circuit load range, the gold-clad twin layer contact is recommended. If there is a danger of the current being less than 0.5 A, for instance if the contact is being turned on and off, the gold-clad triple layer type is recommended. 2. Characteristics Mechanical life (O.T.: Specified value) Electrical life at rated load (O.T.: Max.) Insulation resistance 3. Operating characteristics Leaf lever Other types Silver alloy contact type Gold-clad contact type Dielectric strength Between non-continuous terminals Between each terminal and other exposed metal parts Between each terminal and ground Vibration resistance (Pin plunger type) Shock resistance (Pin plunger type) Contact resistance (Initial) Allowable operating speed (at no load) Max. operating cycle rate (at no load) Ambient temperature Unit weight Silver alloy contact type Gold-clad contact type Type of actuator Operating force, Max. Release force, Min. Pin plunger 0.98N 1.47N 0.15N 0.20N Short hinge lever 0.39N 0.59N 0.034N 0.039N Hinge lever 0.34N 0.54N 0.029N 0.034N Long hinge lever 0.25N 0.44N 0.025N 0.029N Simulated roller lever 0.34N 0.54N 0.029N 0.034N Roller lever 0.39N 0.59N 0.034N 0.039N Leaf lever 0.88N 1.08N 0.17N 0.20N Min. 5x10 5 (at 60 cpm) Min. 5x10 6 (at 60 cpm) Min. 5x10 4 (at 20 cpm) Min. 2x10 5 (at 20 cpm) Min. 100 MΩ (at 500 V DC insulation resistance meter) 1,000 Vrms 1,500 Vrms 1,500 Vrms 10 to 55 Hz at single amplitude of 0.75 mm (Contact opening Max. 1 msec.) Min. 294 m/s 2 (Contact opening Max. 1 msec.) Dust protected type (IP50): Max. 50 mω (By voltage drop 1 A 6 to 8 V DC) Immersion protected type (IP67): Max. 100 mω Dust protected type (IP50): Max. 100 mω (By voltage drop 0.1 A 6 to 8 V DC) Immersion protected type (IP67): Max. 150 mω 0.1 to 500 mm/sec. 120 cpm 40 C to +85 C 40 F to +185 F Approx. 2 g.071 oz (IP50 type) Pretravel, Max Movement differential, Max Overtravel, Min Operating position, 8.4± ± ± ± ± ± ± ± ± ± ± ± ± ±

43 ABS1,4,5 DIMENSIONS General tolerance: ±0.25 ± Dust protected type 1-(1).110 quick-connect terminal Pin plunger 7.6± ±.012 Pretravel 0.6 max..024 max. 1.7 dia..067 dia ± ± ± ± ± ± ±0.05 dia..047±.002 dia ± ± ±0.1 C ± ± ± ± ± ± ± ± ±.012 Operating Position 8.4± ± dia. dia. 11.8± ± ± ±.008 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from stand-off, 8.4± ± ± ±.016 Short hinge lever ± ±.016 R Pretravel 2.5 max..098 max. Operating Position 8.8± ± ± ±.035 (3.7) (.146) Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from stand-off, 8.8± ± ± ±.035 Hinge lever 7.15± ±.016 R Pretravel 2.8 max..110 max. (3.7) (.146) Operating Position 8.8± ± ± ±.035 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from stand-off, 8.8± ± ± ±.035 Long hinge lever 13.1± ±.016 R Pretravel 3.5 max..138 max (3.5) (.138) Operating Position 8.8± ± ± ±.051 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from stand-off, 8.8± ± ± ±

44 ABS1,4,5 Simulated roller lever General tolerance: ±0.25 ± ± ±.016 R R Pretravel 2.8 max..110 max. (3.5) (.138) Operating Position 11.65± ± ± ±.035 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from stand-off, 11.65± ± ± ±.035 Roller lever 5.15± ±.016 R Pretravel 2.5 max..098 max. Operating Position 14.5± ± ± ± dia..197 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from stand-off, 14.5± ± ± ± (2) Solder terminal ± ± ± ± ± ± ± ± ± ± ± ± ± ± dia. dia. 1.85± ± ± ± ± ± ± ± ± ±.004 Remarks: Dimensions of the actuator types are the same as those of corresponding.110 quick-connect terminal types. 1-(3) PC board terminal Straight type ± ± ± ± ± ± ± ± ± ± ± ± dia. dia. 1.85± ± ± ± ± ± ± ± ± ± ±0.05 dia..047±.002 dia. 8.7± ± ± ±.004 Remarks: Dimensions of the actuator types are the same as those of corresponding.110 quick-connect terminal types. 43

45 ABS1,4,5 Right angle type General tolerance: ±0.25 ± ±0.05 dia ±.002 dia. 5.08± ± ± ± ± ± ± ± ± ± Remarks: Dimensions of the actuator types are the same as those of corresponding.110 quick-connect terminal types. Left angle type 3-1.5±0.05 dia ±.002 dia. 5.08± ± ± ± ± ± C0.3 (2.8) (.110) ± ± ± ± ± ± ± ± Remarks: Dimensions of the actuator types are the same as those of corresponding.110 quick-connect terminal types. 2. Immersion protected type Wire leads Pin plunger Straight type ± ± dia. dia. COM NO NC Thickness of the lead wire: 0.5 mm 2 UL/CSA approved type and Right/Left angle type: AWG #20 Color of the lead wire: COM...Black N.C....Red N.O....White Remarks: 1. Other dimensions are the same as those of.110 quick-connect terminal types. 2. Dimensions of the actuator types are the same as those of corresponding.110 quickconnect terminal types. 5±2.197±.079 Right angle type Left angle type 5±2.179± ± ±394 5±2.197± ± ±

46 ABS1,4,5 Leaf lever General tolerance: ±0.25 ±.010 Straight type ± ±.012 8±1.315± Pretravel 4.5 max..177 max. Free Position (16.5) (.650) Operating Position 14.5± ±.059 Totaltravel Position (10.5 min.) (.413) Thickness of the lead wire: 0.5 mm 2 UL/CSA approved type and Right/Left angle type: AWG #20 Color of the lead wire: COM...Black N.C....Red N.O....White ± ± dia. dia ± ±.394 5±2.197± ± ±.016 Right angle type Left angle type ±2.197± ± ± ±2.197± ± ±

47 ABV1 HIGH ENVIRONMENTAL RESISTANCE VDE TURQUOISE SWITCHES V TYPE (ABV) FEATURES Miniature size ( mm) ( inch) Sealed construction for use in adverse environment-sealed construction by epoxy resin and rubber cap keeps off the cause of miscontact such as dust Conforming to IP67* of IEC protective construction classification Elastomer double molding technology, an industry first and ultrasonic swaging technology contribute to uniform seling in high production quantities UL/CSA/VDE/SEMKO approved * Based on the protective construction classification of IED, items which satisfy the test requirements are denoted with an IP designation. TYPICAL APPLICATIONS Automotives Agricultural devices Industrial equipment ORDERING INFORMATION Ex. ABV Type of switch ABV1: Turquoise switch V type Terminal 2:.187 quick-connect terminal 6: Wire leads Contact arrangement 1: SPDT 2: SPST-NC 3: SPST-NO Actuator 0: Pin plunger 2: Hinge lever 4: Simulated roller lever 5: Short roller lever 6: Roller lever Remarks: 1. Standard packing: Dust protected type 50 pcs./carton, 500 pcs./case; Immersion protected type 50 pcs./case. 2. Not every combination is available. Please refer to the following table, PRODUCT TYPES. Operating force by pin plunger (max.) 4: 0.98 N 5: 1.96 N Contact 1: Gold-clad 0: Silver-alloy CONSTRUCTION.187 quick-connect terminal Wire leads Rubber cap Ultrasonic swaging technology contribute for sealing Epoxy resin Epoxy resin (include) Wire leads 46

48 PRODUCT TYPES Silver-alloy Contact Silver-alloy Actuator Pin plunger Hinge lever Simulated roller lever Short roller lever Roller lever Contact Arrangement SPDT SPST-NC SPST-NO SPDT SPST-NC SPST-NO SPDT SPST-NC SPST-NO SPDT SPST-NC SPST-NO SPDT SPST-NC SPST-NO Remarks: When ordering UL/CSA approved types, please attach suffix 9 to the part number. When ordering VDE/SEMKO approved types, please attach suffix 8 to the part number. Operating force, Max. 187 Quick-connect terminal Wire Leads 0.98 N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV ABV1 47

49 ABV1 Gold-clad Contact Gold-clad Actuator Pin plunger Hinge lever Simulated roller lever Short roller lever Roller lever Contact Arrangement SPDT SPST-NC SPST-NO SPDT SPST-NC SPST-NO SPDT SPST-NC SPST-NO SPDT SPST-NC SPST-NO SPDT SPST-NC SPST-NO Remarks: When ordering UL/CSA approved types, please attach suffix 9 to the part number. When ordering VDE/SEMKO approved types, please attach suffix 8 to the part number. Operating force, Max. 187 Quick-connect terminal Wire Leads 0.98 N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV N ABV ABV SPECIFICATIONS 1. Contact rating Type Standard rating Low-level rating Gold-clad contact Silver-alloy 3 A 250 V AC (O.F N) 1 A 250 V AC (O.F N) 5 A 250 V AC (O.F N) 3 A 250 V AC (O.F N) 5 ma 6 V DC 2 ma 12 V DC 1 ma 24 V DC 48

50 2. Characteristics Mechanical life (O.T.: Specified value) Electrical life Insulation resistance Note: *1 O.F. 0.98N type is Min (at 20 com) Min. 5x10 6 (at 60 cpm) Nominal rating (O.T.: Max.) Min (at 20 cpm)* 1 Low-level rating (O.T.: Specified value) Dielectric strength Between non-continuous terminals Between each terminal and other exposed metal parts Between each terminal and ground Vibration resistance Shock resistance Contact resistance Silver alloy contact type Gold-clad contact type Allowable operating speed (at no load) Max. operating cycle rate (at no load) Ambient temperature (at no load) Unit weight Min (at 20 cpm) Min. 100 MΩ (at 500 V DC insulation resistance meter) ABV1 1,000 Vrms 2,000 Vrms 2,000 Vrms 10 to 55 Hz at single amplitude of 0.75 mm (Contact opening: max. 1 msec.) Min. 294 m/s 2 (Contact opening: Max. 1 msec.) Dust protected type (IP50): Max. 50 mω Immersion protected type (IP67): Max. 100 mω (By voltage drop 1 A 6 to 8 V DC) Dust protected type (IP50): Max. 50 mω Immersion protected type (IP67): Max. 100 mω (By voltage drop 0.1 A 6 to 8 V DC) 1 to 500 mm/sec. 120 cpm 40 C to +85 C 40 F to +185 F Approx. 7 g.247 oz (IP50 type) 3. Operating characteristics Type of actuator Operating force, Max. Release force, Min. Pin plunger 1.96N 0.98N 0.39N 0.25N Hinge lever 1.18N 0.59N 0.13N 0.098N Simulated roller lever 1.18N 0.59N 0.13N 0.098N Short roller lever 2.16N 1.08N 0.39N 0.20N Roller lever 1.18N 0.59N 0.13N 0.098N ( ): Low force type Pretravel, Max Movement differential, Max Overtravel, Min Operating position, 14.7± ± ± ± ± ± ± ± ± ±.047 DIMENSIONS General tolerance: ±0.4 ± Dust protected type 1-(1).187 quick-connect terminal Pin plunger Pretravel 1.6 max ± ± dia. dia Operating Position 14.7± ± ± ± ± ± Pretravel, Max. Movement differential, Max. Overtravel, Min. Operating position, ± ±

51 ABV1 Hinge lever General tolerance: ±0.25 ±.010 Pretravel 3.2 max..126 max. R ± ± Operating Position 15.3± ± Pretravel, Max. Movement differential, Max. Overtravel, Min. Operating position, ± ±.047 Simulated roller lever Pretravel 3.2 max..126 max. Operating Position 18.5± ± ± ±.020 R Pretravel, Max. Movement differential, Max. Overtravel, Min. Operating position, ± ±.047 Short roller lever Pretravel 1.6 max..063 max. 20.6± ± Operating Position 20.7± ±.031 R dia..189 dia. Pretravel, Max. Movement differential, Max. Overtravel, Min. Operating position, ± ±.031 Roller lever Pretravel 3.2 max..126 max. 34.2± ± Operating Position 20.7± ±.047 R dia..189 dia. Pretravel, Max. Movement differential, Max. Overtravel, Min. Operating position, ± ± Immersion protected type Wire Leads Pretravel 1.6 max..063 max. Operating Position 14.7± ± ± ± ± ± dia. dia. 22.2± ± ± ± Thickness of the lead wire: Standard type: 0.75mm 2 UL/CSA approved type: AWG #18 Color of the lead wire COM...black N.C....red N.O....white 50

52 HIGH CONTACT CAPACITY, PRECISE OPERATION FEATURES 15 A High current switching capacity and high precision Wide allowance of operating speed Versatile variety of actuators UL/CSA approved NZ BASIC (AM1) SWITCHES AM1 TYPICAL APPLICATION General industrial machinery Medical equipment Measuring instruments Transportation equipment Home electric appliances ORDERING INFORMATION Ex. AM K Type of switch NZ basic (AM1) switch Upper body cover shape & terminal 1: Flat, solder terminal 3: Flat, screw terminal 5: Grooved, solder terminal 7: Grooved, screw terminal Upper body cover shape Flat Grooved Basic specifications 0: Standard type 1: Oil tight type 3: Reversed action type 4: One way type Remarks: Not every combination is available. Please refer to the following table, PRODUCT TYPES. Actuators 0: Pin plunger 1: Hinge lever (leaf spring) 3: Hinge roller lever (roller, leaf, spring) 4: Hinge short roller lever 5: Overtravel plunger 6: Compact overtravel plunger 7: Panel mount plunger 811: Panel mount roller plunger 812: Panel mount cross roller plunger TERMINAL VARIATION Standard types, reversed action types and oil tight types are available in two terminal designs, solder and screw terminals, as shown in the above columns: Differences in dimension between solder and screw terminals are as follows; Solder terminal Screw terminal N.O. CIRCUT N.C. CIRCUT C NO NC Terminal plate M4 screw P

53 AM1 PRODUCT TYPES 1. Standard type Actuator Solder terminal Screw terminal Pin plunger AM1100K AM1300K Over travel plunger AM1105K AM1305K Compact over travel plunger AM1106K AM1306K Panel mount plunger AM1107K AM1307K Panel mount roller plunger AM110811K AM130811K Panel mount cross roller plunger AM110812K AM130812K Flexible leaf lever AM1101K AM1301K Flexible roller leaf lever AM1103K AM1303K Rigid lever AM1501K AM1701K Rigid short roller lever AM1504K AM1704K Rigid roller lever AM1503K AM1703K One way type Rigid short roller lever AM1544K AM1744K One way type Rigid roller lever AM1543K AM1743K Reversed action type Rigid lever AM1531K AM1731K Reversed action type Rigid short roller lever AM1534K AM1734K Reversed action type Rigid roller lever AM1533K AM1733K 2. Oil tight types Actuator Solder terminal Screw terminal Rigid lever AM1511K AM1711K Rigid short roller lever AM1514K AM1714K Rigid roller lever AM1513K AM1713K Remarks: 1. Standard part number indicates UL/CSA mark. 2. Standard packing for inner carton: 20cps. SPECIFICATIONS 1. Contact Rating Type Standard types One way types Reversed action types Oil tight types Voltage Resistive load Inductive load Motor or lamp load (cos φ = 1) (cos φ = 0.6 to 0.7) N.C. N.O. 125 V AC 15 A 10 A 4 A 2 A 250 V AC 15 A 10 A 3 A 1.5 A 480 V AC 3 A 2 A 1.5 A 0.75 A 125 V DC 0.5 A 0.05 A 250 V DC 0.25 A 0.03 A 125 V AC 15 A 10 A 3 A 1.5 A 250 V AC 10 A 6 A 2 A 1.0 A 125 V DC 0.5 A 0.05 A 2. Characteristics Expected life Mechanical Electrical (O.T.: Max.) Item Pin plunger types (O.T.: specified value) Other types (O.T.: specified value) Insulation resistance Between open terminals Dielectric Between each terminal and other exposed metal parts strength Between each terminal and ground Contact resistance (initial) (by voltage drop, 1 A, 6 8 V DC) Vibration resistance (Pin plunger type) Shock Pin plunger types resistance Other types Allowable operating speed (at no load) Max. operating cycle rate (at no load) Ambient temperature Weight Specifications Min (60 cpm) (at rated overtravel) (Oil tight: Min ) Min (60 cpm) (at rated overtravel) (Oil tight: Min ) Min (20 cpm) (at rated load) (Oil tight: Min ) Min. 100 MΩ(at 500 V DC) 1,000 Vrms for 1 min. 2,000 Vrms for 1 min. 2,000 Vrms for 1 min. Max. 50 mω Single amplitude: 0.75 mm, 10 to 55 Hz (contact opening: max. 1 msec.) Min. 300 m/s 2 (contact opening: max. 1 msec.) Min. 50 m/s 2 (contact opening: max. 1 msec.) 0.1 to 1,000 mm/sec. (at pin plunger position) 240 cpm 25 C to +80 C 13 F to +176 F (no freezing at low temperature) Approx. 20 to 55 g.705 to oz 52

54 OPERATING CHARACTERISTICS Standard types Types of actuator Pin plunger Overtravel plunger Compact overtravel plunger AM1 Panel mount plunger Operating force, max N Release force, min N Pretravel, max Movement differential, max Overtravel, min Operating position, 15.9± ± ± ± ± ± ± ±.031 Types of actuator Panel mount roller plunger Panel mount cross roller plunger Flexible leaf lever Standard types (cont' d) Types of actuator Rigid lever Rigid short roller lever Rigid roller lever Operating force, max N 1.57 N 0.98 N Release force, min N 0.42 N 0.2 N Pretravel, max Movement differential, max Overtravel, min Operating position, 19.1± ± ± ± ± ±.028 One way types Types of actuator Rigid short roller lever Rigid roller lever Operating force, max N 1.67 N Release force, min N 0.42 N Pretravel, max Movement differential, max Overtravel, min Free position, max Operating position, 30.2± ± ± ±.016 Flexible roller leaf lever Operating force, max N 1.47 N Release force, min N 0.14 N Pretravel, max Movement differential, max Overtravel, min Operating position, 33.3± ± ± ± ± ±.031 Reversed action types Types of actuator Rigid lever Rigid short roller lever Rigid roller lever Operating force, max N 5.30 N 2.35 N Release force, min N 1.67 N 0.56 N Pretravel, max Movement differential, max Overtravel, min Operating position, 19.1± ± ± ± ± ±.031 Oil tight types Types of actuator Rigid lever Rigid short roller lever Rigid roller lever Operating force, max N 1.67 N 0.98 N Release force, min N 0.42 N 0.20 N Pretravel, max Movement differential, max Overtravel, min Operating position, 19.1± ± ± ± ± ±

55 AM1 DIMENSIONS General tolerance: ±0.4 ± Standard types Pin plunger AM1100K (Solder terminal) AM1300K (Screw terminal) P.T. O.P ± ± ± ± ± ± dia. hole Operating force, max. Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 3.63 N 1.12 N ± ±.016 Overtravel plunger AM1105K (Solder terminal) AM1305K (Screw terminal) P.T. O.P. 23.3± ±.012 Plunger: Hardening steel dia dia..250 Operating force, max. Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 3.63 N 1.12 N ± ±.020 Compact over plunger AM1106K (Solder terminal) AM1306K (Screw terminal) O.P Plunger: Plastic P.T. 0.4 max ± ± ± ± dia dia. dia. Operating force, max. Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 3.63 N 1.12 N ± ±.020 Panel mount plunger AM1107K (Solder terminal) AM1307K (Screw terminal) Plunger: Plastic P.T. 0.4 max ± ±.012 O.P. ± ± ± ± dia. dia dia..325 R8.315 M12 P1 Lock nut (2 thick) Nut (2 thick) Operating force, max. Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 3.63 N 1.12 N ± ±

56 AM1 Panel mount roller plunger General tolerance: ±0.4 ±.016 AM110811K (Solder terminal) AM130811K (Screw terminal) P.T. 0.4 max..016 O.P. ± ± ± ± ± ± Roller 12.7 dia dia..181 : Plastic M12 P1 Nut (2 thick) Operating force, max. Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 3.63 N 1.12 N ± ± dia. dia. Panel mount cross roller plunger AM110812K (Solder terminal) AM130812K (Screw terminal) P.T. 0.4 max..016 O.P. ± ± ± ± ± ± Roller 12.7 dia dia..181 : Plastic M12 P1 Nut (2 thick) Operating force, max. Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 3.63 N 1.12 N ± ± dia. dia. Dimensions and Operating characteristics are the same as those of Panel mount roller plunger type. However, the roller joins the switch body at an angle of 90. Flexible leaf lever AM1101K (Solder terminal) AM1301K (Screw terminal) F.P. O.P. 49.6± ±.031 Leaf: Stainless steel Operating force, max. Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 1.47 N 0.14 N ± ±.031 Flexible roller leaf lever AM1103K (Solder terminal) AM1303K (Screw terminal) F.P. O.P. 46± ±.031 Leaf: Stainless steel Roller 9.5 dia. 4: Plastic Operating force, max. Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 1.47 N 0.14 N ± ±

57 AM1 Rigid lever General tolerance: ±0.4 ±.016 AM1501K (Solder terminal) AM1701K (Screw terminal) 20.1± ± R63.5 Lever: Stainless steel F.P. O.P Operating force, max. Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 0.69 N 0.14 N ± ±.028 Rigid short roller lever AM1504K (Solder terminal) AM1704K (Screw terminal) 20.1± ± R26.7 O.P. F.P. Roller 9.5 dia. 4: Plastic Operating force, max. Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 1.57 N 0.42 N ± ±.016 Rigid roller lever AM1503K (Solder terminal) AM1703K (Screw terminal) 20.1± ± R48.3 O.P. F.P. Roller 9.5 dia. 4: Plastic Operating force, max. Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 0.98 N 0.2 N ± ± One way types This type is operated only to one direction, not to the reversed direction by the construction of the roller lever, pivoting away from the cam on the return stroke. Rigid short roller lever AM1544K (Solder terminal) AM1744K (Screw terminal) 27.8 max max. 20.1± ±.020 R O.P. F.P. Roller 4.75 dia. 4.75: Plastic Operating force, max. Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 2.23 N 0.42 N ± ±

58 AM1 Rigid roller lever General tolerance: ±0.4 ±.016 AM1543K (Solder terminal) AM1743K (Screw terminal) 34.1 max max. 20.1± ± R31 O.P. F.P. Roller 9.5 dia. 4: Plastic Operating force, max. Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 1.67 N 0.42 N ± ± Reversed action types When the actuator is operated, the switching mechanism returns to the free position. Extraordinary force by pushing the plunger too much is not put on the switching mechanism, which means stability in life. Rigid lever AM1531K (Solder terminal) AM1731K (Screw terminal) 20.1± ± ± ± ± ± ± ± R dia. hole Lever: Stainless steel F.P. O.P Operating force, max. Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 1.67 N 0.27 N ± ±.031 Rigid short roller lever AM1534K (Solder terminal) AM1734K (Screw terminal) 20.1± ± R19 O.P. Roller 9.5 dia. 4: Plastic F.P. Operating force, max. Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 5.30 N 1.67 N ± ±.020 Rigid roller lever AM1533K (Solder terminal) AM1733K (Screw terminal) 20.1± ± R41 Roller 9.5 dia. 4: Plastic O.P. F.P. Operating force, max. Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 2.35 N 0.56 N ± ±

59 AM1 4. Oil tight types General tolerance: ±0.4 ±.016 The pushbutton part is sealed with the rubber cap and the connected part between the cap and body is also coated with resin so that these parts are kept off from foreign matters. This type has resistance to oil. Rigid lever Operating force, 0.69 N max. AM1511K (Solder terminal) AM1711K (Screw terminal) 20.1± ±.020 Plunger seal R63.5 Lever: Stainless steel F.P. O.P Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 0.14 N ± ±.028 Rigid short roller lever AM1514K (Solder terminal) AM1714K (Screw terminal) 20.1± ± ± ±0.8 Plunger seal R26.7 O.P. F.P. Roller 9.5 dia. 4: Plastic Operating force, max. Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 1.67 N 0.42 N ± ±.016 Rigid roller lever AM1513K (Solder terminal) AM1713K (Screw terminal) 20.1± ± ± ±.032 Plunger seal R48.3 F.P. O.P. Roller 9.5 dia. 4: Plastic Operating force, max. Release force, min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position, 0.98 N 0.20 N ± ±

60 AM1 TERMINAL COVER FOR NZ BASIC SWITCHES General tolerance: ±0.4 ±.016 Terminal cover (for the standard type with soldering terminal) AA7000 R Terminal cover (for the standard type with screw terminal) R ± ±.004 R ± ± Terminal cover can protect switches from external force and the leakage between terminals can be avoided. Also it can be a simple safety protector because the direct touch of fingers to terminals can be avoided. 2. Nylon 66 is used for higher durability. 3. The height of terminal cover for the solder types is lower than terminal cover for the screw types. 4. AA7000 and AA8000 have 6 knoch-out portions. Lead wire can be taken out from any desired portion. AA8000 R R R NOTES 1. Regarding fastening of switch body 1) In fastening the switch body, use M4 mounting screws to attach switches with the torque 1.5 N m or less. 2) After mounting and wiring, the insulation distance between ground and each terminal should be confirmed as sufficient. 2. Adjustment of the operating device The operating device should be positioned so that it applies no stress to the pushbutton or actuator when the switch is in the open position. If this condition is exceeded, the mechanical and electrical performance will be impaired. In addition, the force applied by the operating device should be in a perpendicular direction. Even if the pushbutton is used in the full total travel position, there will be no influence on the life of the switch. 3. Soldering operations Soldering should be done in less than 5 seconds, with a 60 watt iron (tip temperature = 350 C 662 F max.). Care should be taken not to apply force to the terminal during soldering. 4. Avoid using switches in the following conditions: In corrosive gases such as hydrogen sulfide. In flammable or explosive gases such as gasoline or thinner etc. In a dusty environment. In an ambient humidity over 85%. In the conditions where the perpendicular operating speed is less than 0.1 mm/sec. or more than 1,000 mm/sec. In a silicon atmosphere. 5. Others Caution should be taken not to drop switches. 59

61 AM5 VDE MINIATURE SWITCHES WITH HIGH PRECISION QV (AM5) SWITCHES FEATURES High precision as a result of designing ideal spring by using computer analysis O.P. 14.7±0.4mm.579±.016inch Reliable design with shock resistance min. 980 m/s 2 {100 G} High inrush resistance 160A Wide variety of contact ratings and terminal types UL/CSA/VDE/SEMKO approved Standard type contact gap is 1mm.039inch. Please consult us if you need more than 1mm.039inch contact gap. TYPICAL APPLICATION Home appliances Vending machines Amusement and communication equipment Copiers General industrial machines CONSTRUCTION 1. Silver alloy contact 2. Gold clad contact ORDERING INFORMATION Ex. AM C 5 R Type of Operating force by Contact rating Terminals Actuators Terminals switch pin plunger (max.) Guard AM5: QV switch 00: 0.1 A (Gold clad) 06: 6 A (Silver alloy) 11: 11 A (Silver alloy) 16: 16 A (Silver alloy) 21: 21 A (Silver alloy) (Product is end of life) 1: Bottom COM, SPDT 2: Bottom COM, SPST-NC 3: Bottom COM, SPST-NO 4: Side COM, SPDT 5: Side COM, SPST-NC 6: Side COM, SPST-NO 0: Pin plunger 1: Short hinge lever 2: Hinge lever 3: Long hinge lever 4: Simulated roller lever 5: Short roller lever 6: Roller lever (A:.187 Quickconnect/solder terminal) C:.187 Quickconnect terminal D:.250 Quickconnect terminal 3: 0.49 N 4: 0.98 N 5: 1.96 N 6: 2.94 N 7: 3.92 N R: Right hand guarded L: Left hand guarded Remarks: 1. Not every combination is available. Please refer to the table, PRODUCT TYPES Quick connect/solder terminal and 2.94 N operating force types are custom ordered. Please consult us. 3. When ordering agency standard approved types, please attach the following number to the part number. 9: UL/CSA rated 4: UL/CSA 10 5 rated 3: UL/CSA rated, VDE and SEMKO approved 31: UL/CSA 10 5 rated, VDE and SEMKO approved 8: VDE and SEMKO approved 60

62 TERMINALS.187 Quick-connect terminal.187 Quick-connect/solder terminal Bottom COM terminal.250 Quick-connect terminal Bottom COM terminal AM5 GUARDS Guarded types are available only for Side COM terminal type (.187 Quick-connect). All types of bottom COM are not guarded. NC Left hand guarded NC 1 2 NO NO 3 C C Side COM terminal Side COM terminal Right hand guarded 1 NC 2 NO 3 1 NC 2 NO 3 C C Dimensions.187 Quick-connect terminal Dimensions 1.55 dia..061 dia Dimensions.187 Quick-connect/solder terminal dia dia ± ±.006 R R PRODUCT TYPES A type (Gold clad contact).187 Quick-connect terminal (Guardless) 1) Bottom COM terminal Pin plunger Actuator Short hinge lever Hinge lever Long hinge lever Simulated roller lever Short roller lever Roller lever Operating force, Max. Contact arrangement Contact arrangement SPDT SPST-NC SPST-NO 0.49 N AM50010C3 AM50020C3 AM50030C N AM50010C4 AM50020C4 AM50030C N AM50010C5 AM50020C5 AM50030C N AM50011C3 AM50021C3 AM50031C N AM50011C4 AM50021C4 AM50031C N AM50011C5 AM50021C5 AM50031C N AM50012C3 AM50022C3 AM50032C N AM50012C4 AM50022C4 AM50032C N AM50012C5 AM50022C5 AM50032C N AM50013C3 AM50023C3 AM50033C N AM50013C4 AM50023C4 AM50033C N AM50013C5 AM50023C5 AM50033C N AM50014C3 AM50024C3 AM50034C N AM50014C4 AM50024C4 AM50034C N AM50014C5 AM50024C5 AM50034C N AM50015C3 AM50025C3 AM50035C N AM50015C4 AM50025C4 AM50035C N AM50015C5 AM50025C5 AM50035C N AM50016C3 AM50026C3 AM50036C N AM50016C4 AM50026C4 AM50036C N AM50016C5 AM50026C5 AM50036C5 61

63 AM5 2) Side COM terminal Pin plunger Actuator Short hinge lever Hinge lever Long hinge lever Simulated roller lever Short roller lever Roller lever Operating force, Max. Contact arrangement Contact arrangement SPDT SPST-NC SPST-NO 0.49 N AM50040C3 AM50050C3 AM50060C N AM50040C4 AM50050C4 AM50060C N AM50040C5 AM50050C5 AM50060C N AM50041C3 AM50051C3 AM50061C N AM50041C4 AM50051C4 AM50061C N AM50041C5 AM50051C5 AM50061C N AM50042C3 AM50052C3 AM50062C N AM50042C4 AM50052C4 AM50062C N AM50042C5 AM50052C5 AM50062C N AM50043C3 AM50053C3 AM50063C N AM50043C4 AM50053C4 AM50063C N AM50043C5 AM50053C5 AM50063C N AM50044C3 AM50054C3 AM50064C N AM50044C4 AM50054C4 AM50064C N AM50044C5 AM50054C5 AM50064C N AM50045C3 AM50055C3 AM50065C N AM50045C4 AM50055C4 AM50065C N AM50045C5 AM50055C5 AM50065C N AM50046C3 AM50056C3 AM50066C N AM50046C4 AM50056C4 AM50066C N AM50046C5 AM50056C5 AM50066C5 Remarks: 1. Regarding side COM terminal types, right hand guarded types and left hand guarded types are available. When ordering, please attach suffix R for right hand guarded types or L for left hand guarded types to the part number. <ex.> Guardless type Right hand guarded type AM50040C4 AM50040C4R 2. When ordering agency standard approved types, please attach the following number to the part number. 9: UL/CSA rated 4: UL/CSA 10 5 rated 3: UL/CSA rated, VDE and SEMKO approved 31: UL/CSA 10 5 rated, VDE and SEMKO approved 8: VDE and SEMKO approved 3. Also.187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A. <ex.>.187 Quick-connect terminal.187 Quick-connect/solder terminal AM50010C4 AM50010A Quick-connect terminal is available for operating force min. 0.49N types. When ordering, change the eighth digit of part number C to D. <ex.>.187 Quick-connect terminal.250 Quick-connect terminal AM50010C3 AM50010D3 62

64 2. 6A type (Silver alloy contact).187 Quick-connect terminal (Guardless) 1) Bottom COM terminal Actuator Operating force, Max. Contact arrangement Contact arrangement SPDT SPST-NC SPST-NO 0.49 N AM50610C3 AM50620C3 AM50630C N AM50610C4 AM50620C4 AM50630C4 Pin plunger 1.96 N AM50610C5 AM50620C5 AM50630C5 *2.94 N AM50610C6 AM50620C6 AM50630C N AM50610C7 AM50620C7 AM50630C N AM50611C3 AM50621C3 AM50631C N AM50611C4 AM50621C4 AM50631C4 Short hinge lever 2.16 N AM50611C5 AM50621C5 AM50631C5 *3.14 N AM50611C6 AM50621C6 AM50631C N AM50611C7 AM50621C7 AM50631C N AM50612C3 AM50622C3 AM50632C N AM50612C4 AM50622C4 AM50632C4 Hinge lever 1.18 N AM50612C5 AM50622C5 AM50632C5 *1.77 N AM50612C6 AM50622C6 AM50632C N AM50612C7 AM50622C7 AM50632C N AM50613C3 AM50623C3 AM50633C N AM50613C4 AM50623C4 AM50633C4 Long hinge lever 0.59 N AM50613C5 AM50623C5 AM50633C5 *0.88 N AM50613C6 AM50623C6 AM50633C N AM50613C7 AM50623C7 AM50633C N AM50614C3 AM50624C3 AM50634C N AM50614C4 AM50624C4 AM50634C4 Simulated roller lever 1.18 N AM50614C5 AM50624C5 AM50634C5 *1.77 N AM50614C6 AM50624C6 AM50634C N AM50614C7 AM50624C7 AM50634C N AM50615C3 AM50625C3 AM50635C N AM50615C4 AM50625C4 AM50635C4 Short roller lever 2.16 N AM50615C5 AM50625C5 AM50635C5 *3.14 N AM50615C6 AM50625C6 AM50635C N AM50615C7 AM50625C7 AM50635C N AM50616C3 AM50626C3 AM50636C N AM50616C4 AM50626C4 AM50636C4 Roller lever 1.18 N AM50616C5 AM50626C5 AM50636C5 *1.77 N AM50616C6 AM50626C6 AM50636C N AM50616C7 AM50626C7 AM50636C7 Remarks: 1. Regarding side COM terminal types, right hand guarded types and left hand guarded types are available. When ordering, please attach suffix R for right hand guarded types or L for left hand guarded types to the part number. <ex.> Guardless type Right hand guarded type AM50640C4 AM50640C4R 2. When ordering agency standard approved types, please attach the following number to the part number. 9: UL/CSA rated 4: UL/CSA 105 rated 3: UL/CSA rated, VDE and SEMKO approved 31: UL/CSA 10 5 rated, VDE and SEMKO approved 8: VDE and SEMKO approved 3. Also.187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A. <ex.>.187 Quick-connect terminal.187 Quick-connect/solder terminal AM50610C4 AM50610A4 4. * is a custom order. Please consult us Quick-connect terminal is available. When ordering, change the eighth digit of part number C to D. <ex.>.187 Quick-connect terminal.250 Quick-connect terminal AM50610C3 AM50610D3 AM5 63

65 AM5 2) Side COM terminal Pin plunger Actuator Short hinge lever Hinge lever Long hinge lever Simulated roller lever Short roller lever Roller lever Operating force, Max. Contact arrangement Contact arrangement SPDT SPST-NC SPST-NO 0.49 N AM50640C3 AM50650C3 AM50660C N AM50640C4 AM50650C4 AM50660C N AM50640C5 AM50650C5 AM50660C5 *2.94 N AM50640C6 AM50650C6 AM50660C N AM50640C7 AM50650C7 AM50660C N AM50641C3 AM50651C3 AM50661C N AM50641C4 AM50651C4 AM50661C N AM50641C5 AM50651C5 AM50661C5 *3.14 N AM50641C6 AM50651C6 AM50661C N AM50641C7 AM50651C7 AM50661C N AM50642C3 AM50652C3 AM50662C N AM50642C4 AM50652C4 AM50662C N AM50642C5 AM50652C5 AM50662C5 *1.77 N AM50642C6 AM50652C6 AM50662C N AM50642C7 AM50652C7 AM50662C N AM50643C3 AM50653C3 AM50663C N AM50643C4 AM50653C4 AM50663C N AM50643C5 AM50653C5 AM50663C5 *0.88 N AM50643C6 AM50653C6 AM50663C N AM50643C7 AM50653C7 AM50663C N AM50644C3 AM50654C3 AM50664C N AM50644C4 AM50654C4 AM50664C N AM50644C5 AM50654C5 AM50664C5 *1.77 N AM50644C6 AM50654C6 AM50664C N AM50644C7 AM50654C7 AM50664C N AM50645C3 AM50655C3 AM50665C N AM50645C4 AM50655C4 AM50665C N AM50645C5 AM50655C5 AM50665C5 *3.14 N AM50645C6 AM50655C6 AM50665C N AM50645C7 AM50655C7 AM50665C N AM50646C3 AM50656C3 AM50666C N AM50646C4 AM50656C4 AM50666C N AM50646C5 AM50656C5 AM50666C5 *1.77 N AM50646C6 AM50656C6 AM50666C N AM50646C7 AM50656C7 AM50666C7 Remarks: 1. Regarding side COM terminal types, right hand guarded types and left hand guarded types are available. When ordering, please attach suffix R for right hand guarded types or L for left hand guarded types to the part number. <ex.> Guardless type Right hand guarded type AM50640C4 AM50640C4R 2. When ordering agency standard approved types, please attach the following number to the part number. 9: UL/CSA rated 4: UL/CSA 10 5 rated 3: UL/CSA rated, VDE and SEMKO approved 31: UL/CSA 10 5 rated, VDE and SEMKO approved 8: VDE and SEMKO approved 3. Also.187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A. <ex.>.187 Quick-connect terminal.187 Quick-connect/solder terminal AM50610C4 AM50610A4 4. * is a custom order. Please consult us Quick-connect terminal is available. When ordering, change the eighth digit of part number C to D. <ex.>.187 Quick-connect terminal.250 Quick-connect terminal AM50610C3 AM50610D3 64

66 3. 11A type (Silver alloy contact).187 Quick-connect terminal (Guardless) 1) Bottom COM terminal Actuator Operating force, Max. Contact arrangement Contact arrangement SPDT SPST-NC SPST-NO Pin plunger 0.98 N AM51110C4 AM51120C4 AM51130C4 Short hinge lever 1.08 N AM51111C4 AM51121C4 AM51131C4 Hinge lever 0.59 N AM51112C4 AM51122C4 AM51132C4 Long hinge lever 0.29 N AM51113C4 AM51123C4 AM51133C4 Simulated roller lever 0.59 N AM51114C4 AM51124C4 AM51134C4 Short roller lever 1.08 N AM51115C4 AM51125C4 AM51135C4 Roller lever 0.59 N AM51116C4 AM51126C4 AM51136C4 2) Side COM terminal Actuator Operating force, Max. Contact arrangement Contact arrangement SPDT SPST-NC SPST-NO Pin plunger 0.98 N AM51140C4 AM51150C4 AM51160C4 Short hinge lever 1.08 N AM51141C4 AM51151C4 AM51161C4 Hinge lever 0.59 N AM51142C4 AM51152C4 AM51162C4 Long hinge lever 0.29 N AM51143C4 AM51153C4 AM51163C4 Simulated roller lever 0.59 N AM51144C4 AM51154C4 AM51164C4 Short roller lever 1.08 N AM51145C4 AM51155C4 AM51165C4 Roller lever 0.59 N AM51146C4 AM51156C4 AM51166C4 Remarks: 1. Regarding side COM terminal types, right hand guarded types and left hand guarded types are available. When ordering, please attach suffix R for right hand guarded types or L for left hand guarded types to the part number. <ex.> Guardless type Right hand guarded type AM51140C4 AM51140C4R 2. When ordering agency standard approved types, please attach the following number to the part number. 9: UL/CSA rated 4: UL/CSA 10 5 rated 3: UL/CSA rated, VDE and SEMKO approved 31: UL/CSA 10 5 rated, VDE and SEMKO approved 8: VDE and SEMKO approved 3. Also.187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A. <ex.>.187 Quick-connect terminal.187 Quick-connect/solder terminal AM51110C4 AM51110A Quick-connect terminal is available. When ordering, change the eighth digit of part number C to D. <ex.>.187 Quick-connect terminal.250 Quick-connect terminal AM51110C4 AM51110D4 AM A type (Silver alloy contact).187 Quick-connect terminal (Guardless) 1) Bottom COM terminal Actuator Operating force, Max. Contact arrangement Contact arrangement SPDT SPST-NC SPST-NO 1.96 N AM51610C5 AM51620C5 AM51630C5 Pin plunger *2.94 N AM51610C6 AM51620C6 AM51630C N AM51610C7 AM51620C7 AM51630C N AM51611C5 AM51621C5 AM51631C5 Short hinge lever *3.14 N AM51611C6 AM51621C6 AM51631C N AM51611C7 AM51621C7 AM51631C N AM51612C5 AM51622C5 AM51632C5 Hinge lever *1.77 N AM51612C6 AM51622C6 AM51632C N AM51612C7 AM51622C7 AM51632C N AM51613C5 AM51623C5 AM51633C5 Long hinge lever *0.88 N AM51613C6 AM51623C6 AM51633C N AM51613C7 AM51623C7 AM51633C N AM51614C5 AM51624C5 AM51634C5 Simulated roller lever *1.77 N AM51614C6 AM51624C6 AM51634C N AM51614C7 AM51624C7 AM51634C N AM51615C5 AM51625C5 AM51635C5 Short roller lever *3.14 N AM51615C6 AM51625C6 AM51635C N AM51615C7 AM51625C7 AM51635C N AM51616C5 AM51626C5 AM51636C5 Roller lever *1.77 N AM51616C6 AM51626C6 AM51636C N AM51616C7 AM51626C7 AM51636C7 65

67 AM5 2) Side COM terminal Pin plunger Actuator Short hinge lever Hinge lever Long hinge lever Simulated roller lever Short roller lever Roller lever Operating force, Max. Contact arrangement Contact arrangement SPDT SPST-NC SPST-NO 1.96 N AM51640C5 AM51650C5 AM51660C5 *2.94 N AM51640C6 AM51650C6 AM51660C N AM51640C7 AM51650C7 AM51660C N AM51641C5 AM51651C5 AM51661C5 *3.14 N AM51641C6 AM51651C6 AM51661C N AM51641C7 AM51651C7 AM51661C N AM51642C5 AM51652C5 AM51662C5 *1.77 N AM51642C6 AM51652C6 AM51662C N AM51642C7 AM51652C7 AM51662C N AM51643C5 AM51653C5 AM51663C5 *0.88 N AM51643C6 AM51653C6 AM51663C N AM51643C7 AM51653C7 AM51663C N AM51644C5 AM51654C5 AM51664C5 *1.77 N AM51644C6 AM51654C6 AM51664C N AM51644C7 AM51654C7 AM51664C N AM51645C5 AM51655C5 AM51665C5 *3.14 N AM51645C6 AM51655C6 AM51665C N AM51645C7 AM51655C7 AM51665C N AM51646C5 AM51656C5 AM51666C5 *1.77 N AM51646C6 AM51656C6 AM51666C N AM51646C7 AM51656C7 AM51666C7 Remarks: 1. Regarding side COM terminal types, right hand guarded types and left hand guarded types are available. When ordering, please attach suffix R for right hand guarded types or L for left hand guarded types to the part number. <ex.> Guardless type Right hand guarded type AM51640C5 AM51640C5R 2. When ordering agency standard approved types, please attach the following number to the part number. 9: UL/CSA rated 4: UL/CSA 10 5 rated 3: UL/CSA rated, VDE and SEMKO approved 31: UL/CSA 10 5 rated, VDE and SEMKO approved 8: VDE and SEMKO approved 3. Also.187 Quick-connect/solder terminal is available. When ordering, change the eighth digit of part number C to A. <ex.>.187 Quick-connect terminal.187 Quick-connect/solder terminal AM51610C5 AM51610A5 4. * is a custom ordered product. Please consult us Quick-connect terminal is available. When ordering, change the eighth digit of part number C to D. <ex.>.187 Quick-connect terminal.250 Quick-connect terminal AM51610C5 AM51610D A type (Silver alloy contact).250 Quick-connect terminal (Guardless) 1) Bottom COM terminal Actuator Operating force, Max. Contact arrangement Contact arrangement SPDT SPST-NC SPST-NO Pin plunger *2.94 N AM52110D6 AM52120D6 AM52130D N AM52110D7 AM52120D7 AM52130D7 Short hinge lever *3.14 N AM52111D6 AM52121D6 AM52131D N AM52111D7 AM52121D7 AM52131D7 Hinge lever *1.77 N AM52112D6 AM52122D6 AM52132D N AM52112D7 AM52122D7 AM52132D7 Long hinge lever *0.88 N AM52113D6 AM52123D6 AM52133D N AM52113D7 AM52123D7 AM52133D7 Simulated roller lever *1.77 N AM52114D6 AM52124D6 AM52134D N AM52114D7 AM52124D7 AM52134D7 Short roller lever *3.14 N AM52115D6 AM52125D6 AM52135D N AM52115D7 AM52125D7 AM52135D7 Roller lever *1.77 N AM52116D6 AM52126D6 AM52136D N AM52116D7 AM52126D7 AM52136D7 66

68 2) Side COM terminal Pin plunger Actuator Short hinge lever Hinge lever Long hinge lever Simulated roller lever Short roller lever Roller lever Operating force, Max. Contact arrangement Remarks: 1. When ordering agency standard approved types, please attach the following number to the part number. 9: UL/CSA rated 4: UL/CSA 10 5 rated 3: UL/CSA rated, VDE and SEMKO approved 31: UL/CSA 10 5 rated, VDE and SEMKO approved 8: VDE and SEMKO approved 2. * is a custom ordered product. Please consult us. DATA Gold-clad type Range of low-level current voltage Contact arrangement SPDT SPST-NC SPST-NO *2.94 N AM52140D6 AM52150D6 AM52160D N AM52140D7 AM52150D7 AM52160D7 *3.14 N AM52141D6 AM52151D6 AM52161D N AM52141D7 AM52151D7 AM52161D7 *1.77 N AM52142D6 AM52152D6 AM52162D N AM52142D7 AM52152D7 AM52162D7 *0.88 N AM52143D6 AM52153D6 AM52163D N AM52143D7 AM52153D7 AM52163D7 *1.77 N AM52144D6 AM52154D6 AM52164D N AM52144D7 AM52154D7 AM52164D7 *3.14 N AM52145D6 AM52155D6 AM52165D N AM52145D7 AM52155D7 AM52165D7 *1.77 N AM52146D6 AM52156D6 AM52166D N AM52146D7 AM52156D7 AM52166D7 AM5 500 Current (ma) DC voltage (V) SPECIFICATIONS 1. Contact rating Gold clad contact Silver alloy contact Type 0.1A type 6A type 11A type 16A type 21A type Gold clad contact for low level circuit Voltage Remark: The inductive load for DC should have a time constant of 7 ms or less. Resistive load (cos φ ] 1) Inductive load (cos φ ] 0.6 to 0.7) 250V AC 0.1A 0.1A 125V AC 0.1A 0.1A 30V DC 0.1A 0.1A 250V AC 6A 3A 125V AC 6A 3A 125V DC 0.5A 0.5A 250V AC 11A 6A 125V AC 11A 6A 125V DC 0.6A 0.6A 250V AC 16A 10A 125V AC 16A 10A 125V DC 0.6A 0.6A 250V AC 21A 16A 125V AC 21A 16A 125V DC 0.6A 0.6A 6V DC 5mA 12V DC 2mA 24V DC 1mA 67

69 AM5 2. Characteristics Type 21A type (Silver alloy) 16, 11, 6A type (Silver alloy) 0.1A type (Gold clad) Mechanical 10 7 operations (at 60 cpm) Expected life 10 5 operations (at rated load) (min.) Electrical 10 5 Operations (at rated load 20 cpm) operations (at low-level circuit rating) Insulation resistance 100MΩ (at 500V DC) Between terminals 1,000Vrms for 1 min. Dielectric strength Between terminals and other exposed metal parts Between terminals and ground Contact resistance (initial) Vibration resistance (by pin plunger) Shock resistance (by pin plunger) (contact opening: max. 1msec.) Allowable operating speed Maximum operating cycle rate Ambient temperature Weight 2,000Vrms for 1 min. 2,000Vrms for 1 min. 50mΩ (by voltage drop at 1A 6 to 8V DC) 50mΩ (by voltage drop at 0.1A 6 to 8V DC) 10 to 55Hz at simple amplitude of 0.75mm (Contact opening: max. 1msec.) O.F N max. type O.F N to 0.49 N max. type Min. 98 m/s 2 Min. 98 m/s 2 O.F N max. type O.F N max. type Min. 294 m/s 2 Min. 196 m/s 2 Min. 196 m/s 2 O.F N to 3.92 N max. type O.F N max. type Min. 294 m/s 2 Min. 294 m/s to 1,000mm/sec. (at pin plunger) 600cpm 25 to +105 C 13 to +221 F (Not freezing below 0 C 32 F) 6.3g.222oz 3. Operating characteristics Pin plunger 7th digit of part No Operating force, max N 0.98 N 1.96 N 2.94 N 3.92 N Release force, min N 0.25 N 0.49 N 0.74 N 0.98 N Pretravel, max Movement differential, max Overtravel, min Operating position 14.7± ±.016 Short hinge lever 7th digit of part No Operating force, max N 1.08 N 2.16 N 3.14 N 4.12 N Release force, min N 0.20 N 0.39 N 0.59 N 0.78 N Pretravel, max Movement differential, max Overtravel, min Operating position 15.3± ±.020 Hinge lever 7th digit of part No Operating force, max N 0.59 N 1.18 N 1.77 N 2.35 N Release force, min N N 0.20 N 0.29 N 0.39 N Pretravel, max Movement differential, max Overtravel, min Operating position 15.3± ±.039 Long hinge lever 7th digit of part No Operating force, max N 0.29 N 0.59 N 0.88 N 1.18 N Release force, min N N N 0.15 N 0.20 N Pretravel, max Movement differential, max Overtravel, min Operating position 15.3± ±

70 Simulated roller lever 7th digit of part No Operating force, max N 0.59 N 1.18 N 1.77 N 2.35 N Release force, min N N 0.20 N 0.29 N 0.39 N Pretravel, max Movement differential, max Overtravel, min Operating position 18.5± ±.039 Short roller lever 7th digit of part No Operating force, max N 1.08 N 2.16 N 3.14 N 4.12 N Release force, min N 0.20 N 0.39 N 0.59 N 0.78 N Pretravel, max Movement differential, max Overtravel, min Operating position 20.7± ±.020 Roller lever 7th digit of part No Operating force, max N 0.59 N 1.18 N 1.77 N 2.35 N Release force, min N N 0.20 N 0.29 N 0.39 N Pretravel, max Movement differential, max Overtravel, min Operating position 20.7± ±.039 AM5 DIMENSIONS General tolerance: ±0.25 ± Pin plunger Bottom COM terminal (Guardless).187 Quick-connect terminal.250 Quick-connect terminal 1.55 dia dia dia. (P.T.) 1.4 max..055 (O.P.) ± ± ± ± ± C.134 ±.006 ± ± NC NO dia dia (P.T.) 1.4 max..055 (O.P.) ± ± ± ± ± C.134 ±.006 ± ± NC NO ± ± ± dia dia Side COM terminal (Guardless).187 Quick-connect terminal.250 Quick-connect terminal 1.55 dia dia dia. (P.T.) 1.4 max..055 (O.P.) ± ± ± ± ± C.134 ±.006 ± ± NC 2 NO dia dia (P.T.) 1.4 max..055 (O.P.) ± ± ± ± ± C.134 ±.006 ± ± NC NO ± ± dia dia

71 AM5 Side COM terminal General tolerance: ±0.25 ±.010 (Right hand guarded).187 Quick-connect terminal 1.55 dia (P.T.) 1.4 max..055 (O.P.) ± ± ± ± ± C.134 ±.006 ± ± NC NO dia dia Side COM terminal (Left hand guarded) Pin plunger characteristic chart 0.1A type 6A type 11A type 16A type 21A type 7th digit of part No Operating force, max N 0.98 N 1.96 N 2.94 N 3.92 N Release force, min N 0.25 N 0.49 N 0.74 N 0.98 N Pretravel, max Movement differential, max Overtravel, min Operating position 14.7± ± Short hinge lever The dimensions other than drawn above are same as pin plunger type (P.T.) 1.6 max..063 (O.P.) ± ± ± ± Quick-connect terminal 22.1 ± ± ±0.15 C.134 ±.006 ± ± dia dia dia NC NO dia dia dia ± ±.006 ± ± (P.T.) 1.4 max..055 (O.P.) 10.3 ±0.1 ± ± ± A type 6A type 11A type 16A type 21A type 7th digit of part No Operating force, Max. Release force, Min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position 0.59 N N 1.08 N 0.20 N 2.16 N 0.39 N N 0.59 N 15.3± ± N 0.78 N

72 AM5 3. Hinge lever General tolerance: ±0.25 ±.010 (P.T.) 3.2 max..126 (O.P.) ± ± ± ± ± ± ± C.134 ±.006 ± ± NC NO dia dia dia A type 6A type 11A type 16A type 21A type 7th digit of part No Operating force, Max. Release force, Min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position 0.29 N N 0.59 N N 1.18 N 0.20 N N 0.29 N 15.3± ± N 0.39 N The dimensions other than drawn above are same as pin plunger type. 4. Long hinge lever (P.T.) 7.5 max..295 (O.P.) ± ± ± ± ±0.5 ± ± C.134 ±.006 ± ± NC 2 NO dia dia dia A type 6A type 11A type 16A type 21A type 7th digit of part No Operating force, Max. Release force, Min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position 0.15 N N 0.29 N N 0.59 N N N 0.15 N 15.3± ± N 0.20 N The dimensions other than drawn above are same as pin plunger type. 5. Simulated roller lever (P.T.) 3.2 max..126 (O.P.) ± ± R ± ± ±0.5 ± ± C.134 ±.006 ± ± NC 2 NO dia dia dia A type 6A type 11A type 16A type 21A type 7th digit of part No Operating force, Max. Release force, Min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position 0.29 N N 0.59 N N 1.18 N 0.20 N N 0.29 N 18.5± ± N 0.39 N The dimensions other than drawn above are same as pin plunger type. 71

73 AM5 6. Short roller lever General tolerance: ±0.25 ±.010 (P.T.) 1.6 max..063 (O.P.) ± ± ± ± ±0.5 ± ±0.15 C.134 ±.006 ± ± NC NO dia dia dia A type 6A type 11A type 16A type 21A type 7th digit of part No Operating force, Max. Release force, Min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position 0.59 N N 1.08 N 0.20 N 2.16 N 0.39 N N 0.59 N 20.7± ± N 0.78 N The dimensions other than drawn above are same as pin plunger type. 7. Hinge Roller lever (P.T.) 3.2 max..126 (O.P.) ± ± ± ± ±0.5 ± ±0.15 C.134 ±.006 ± ± NC 2 NO dia dia dia A type 6A type 11A type 16A type 21A type 7th digit of part No Operating force, Max. Release force, Min. Pretravel, max. Movement differential, max. Overtravel, min. Operating position 0.29 N N 0.59 N N 1.18 N 0.20 N N 0.29 N 20.7± ± N 0.39 N The dimensions other than drawn above are same as pin plunger type. NOTES 1. Fastening of the switch body 1) Use flat filister head M3 screws to mount switches with less than a 0.49 N m torque. Use of screws washers or adhesive lock is recommended to prevent loosening of the screws. 2) Check insulation distance between ground and each terminal. 3) When the operation object is in the free position, force should not be applied directly to the actuator or pin plunger. Also force should be applied to the pin plunger from vertical direction to the switch. 4) The standard value of overtravel should be the range of 70% to 100% of the rated O.T. value. 2. Soldering operations Soldering should be accomplished in less than 5 seconds, with a 60 watt iron. Care should be taken not to apply force to the terminal during soldering. 3. Varience of operating characteristics When specifying the switch, allow +20% to the listed operating and release forces. 4. Environment Avoid using the switches in the following conditions; In corrosive gases, such as silicon gas In a dusty environment 5. For switching of inductive loads (relays, solenoids, etc.) 1) In order to prevent damage to contacts due to the occurrence of arcing, an arc absorbing circuit should be applied. 2) Care should be taken that occurrence in AC load possibly shorten the expected life. 6. Please assure the quality and reliability of the switch under the actual service condition. 7. It is recommended to use Gold clad contact type in use of low-level circuit rating. 8. Cover and body are press-fitted. Once it is taken apart, it may cause change of characteristics. USE OF CONNECTOR The.187 Quick-connect terminal and.250 Quick-connect terminal accept the all kinds of 1 polarity connectors and the Positive Lock connectors. Please contact the manufacturers directly. receptacle terminal.250 series.187 series Positive Lock connector. (equipped with the lock construction of low insertion type).187 type (1 polarity).250 type (1 polarity).187 type (2 polarities).187 type (3 polarities) 72

74 <CUSTOM ORDERED PRODUCT> MINIATURE SWITCHES WITH HIGH PRECISION (Contact gap: more than 1mm.039inch type) QV (AM5) SWITCHES Conforms with the IEC950 standards for secondary circuit insulation distance. Assures a contact gap of at least 1mm.039inch Can handle high-capacity loads on the secondary side that S-type size switches cannot High inrush and hard impacts resistant Excellent operating position precision UL/CSA/VDE/SEMKO/TÜV approved PRODUCT TYPES Contact rating: 0.1A, 6A, 11A, 16A (250V AC) Terminal shape:.187 Quick connect terminal,.187 Quick connect/solder terminal For other specifications, please consult us. DIMENSIONS AND NOTES Please refer to Standard QV switches catalog for dimensions and notes. SPECIFICATIONS Contact ratings (0.1 to 16 A) Voltage Resistive load Inductive load (cos φ = 1.0) (cos φ ] 0.6 to 0.7) Type 0.1A 6A 11A 16A 0.1A 6A 11A 16A 250V AC 0.1A 6A 11A 16A 0.1A 3A 6A 10A 125V AC 0.1A 6A 11A 16A 0.1A 3A 6A 10A 125V DC 0.1A 0.5A 0.6A 0.6A 0.1A 0.5A 0.6A 0.6A Remark: The inductive load for DC should have a time constant of 7 ms or less. 0.1A type minimum load: 6V DC 5mA (Resistive load) 12V DC 2mA (Resistive load) 24V DC 1mA (Resistive load) Please consult us for further information. 73

75 AH7 HIGH PERFORMANCE MINIATURE SWITCHES WITH WIDE RANGE FEATURES Extra long-life spring mechanism More than 10 7 mechanical operations, 10 5 electrical High contact rating of 15 Amps with an operating force of only 200 g 7.05 oz Safety insulation guard types available Available in a wide operating force and capacity range UL/CSA/VDE/SEMKO approved NV (AH7) SWITCHES (Heart resistant type) TYPICAL APPLICATIONS Home appliances Vending machines Amusement and communication equipment Copiers General industrial machines ORDERING INFORMATION Ex. AH7 Type of switch NV switch Contact arrangement Terminal Actuators 1: Bottom COM terminal SPDT 2: Bottom COM terminal SPST-NC 3: Bottom COM terminal SPST-NO 4: Side COM terminal SPDT 5: Side COM terminal SPST-NC 6: Side COM terminal SPST-NO *2: (Solder terminal without guard) 5:.187 Quick-connect/ solder terminal without guard 8: (.250 Quick-connect terminal) 0: Pin plunger 1: Short hinge lever 2: Hinge lever 3: Long hinge lever 4: Simulated roller lever 5: Short roller lever 6: Roller lever Heat resistant type (Standard) Heat resistant type (Low-level circuit type) Operating force by pin plunger (max.) Remark: Please consult us for * marked product. When ordering international standard approved types, please attach the following number to the part no. 9: UL/CSA rated 8: VDE/SEMKO 4: UL/CSA 10 5 rated 7: UL TV rating Type 0.49N 0.98N 1.96N 3.92N.187 Quick-connect/ solder terminal without guard Solder terminal without guard.250 Quick-connect terminal *(355) *(455) TERMINALS Quick-connect/solder terminal 1) Bottom COM terminal 2. Solder terminal 1) Bottom COM terminal Quick-connect terminal 1) Bottom COM terminal (10) t= (.394) Quick-connect terminal t= (6.5) (.256) (11) t= (.433) Quick-connect terminal 2) Side COM terminal 2)Terminal portion dimensions dia ) Terminal portion dimensions dia..065 (10) (.394) ± ±.004 3) Terminal portion dimensions 3.2*.126* ± ± dia dia..063 * Indicating for the center of 1.6 dia..063 dia. 74

76 TABLE OF PRODUCT TYPES Types Heat resistant type Heat resistant type (Low-level circuit type) Contact rating 15A 250V AC 10A 250V AC 5A 250V AC 3A 250V AC 1A 250V AC PRODUCT TYPES Contact arrangement Schematic Terminals Operating force, max. SPDT SPST- NC SPST- NO 1. Heat resistant type (Standard).187 Quick-connect/solder terminal without guard Actuators Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Short roller lever Roller lever Bottom COM terminal (without guard) Side terminal (without guard).187 Quickconnect/ solder terminal Solder terminal.250 Quickconnect terminal AH7 0.49N 0.98N 1.96N 2.94N 3.92N Operating force, max. Bottom COM terminal Side COM terminal 0.49N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH N AH AH Remarks: 1. When ordering solder terminal, change the fifth digit of part number from 5 to 2. (ex.) AH AH When ordering 2.94N types, insert the number 655 at the seventh digit of part no. instead of 356, 456, 555 or Please consult us for NC and NO types. 4. When ordering international standard approved types, please attach the following number to the part no. 9: UL/CSA rated 8: VDE/SEMKO 7: UL TV rating 2. Heat resistant type (Low-level circuit type) Actuators Operating force, max. Bottom COM terminal Side COM terminal 0.49N AH AH Pin plunger 0.98N AH AH N AH AH N AH AH Short hinge lever 1.08N AH AH N AH AH N AH AH Hinge lever 0.59N AH AH N AH AH N AH AH Long hinge lever 0.29N AH AH N AH AH N AH AH Simulated roller lever 0.59N AH AH N AH AH N AH AH Short roller lever 1.08N AH AH N AH AH N AH AH Roller lever 0.59N AH AH N AH AH Remarks: 1. Please consult us for NC and NO types. 2. As for International standard, please refer to the Information. 75

77 AH7 SPECIFICATIONS 1. Contact rating Contact Operating force by pin plunger (max.) Rating (resistive load) 0.49N 5A 250V AC, 0.5A 125V DC Silver alloy 0.98N 10A 250V AC, 0.6A 125V DC 1.96N, 3.92N 15A 250V AC, 0.6A 125V DC Gold clad 0.49 to 1.96N 3A 250V AC Gold clad low level circuit type (resistive load) Minimum load: 6V DC 5mA 12V DC 2mA 24V DC 1mA 2. Characteristics Contact Silver alloy Gold clad Operating force by pin plunger (max.) 0.49N 0.98N 1.96N, 2.94N, 3.92N 0.49N 0.98N 1.96N Expected Mechanical (at O.T. rated) Min (at 60 cpm) life (min.) Electrical (at O.T. min.) Min (at rated load, 20 cpm) Insulation resistance (min.) Min. 100MΩ (at 500V DC) Between terminals 1,000V AC for 1min. Dielectric strength Between terminals and other exposed metal parts Between terminals and ground 1,500V AC for 1min. 1,500V AC for 1min. Contact resistance (Initial) Max. 50mΩ (by voltage drop at 1A 6 to 8V DC) Max. 50 mω (by voltage drop at 0.1A 6 to 8V DC) Vibration resistance (by pin plunger types) 10 to 55 Hz at amplitude of 0.75mm (Contact opening: max. 1msec.) Shock resistance (by pin plunger types) Min. Allowable operating speed Max. operating cycle rate Ambient temperature Unit weight 98m/s 2 196m/s 2 294m/s 2 98m/s 2 196m/s 2 294m/s to 1,000mm/sec. 600/min. 25 C to +120 C 13 F to +248 F (No freezing below 0 C) 8g.28oz 3. Operating characteristics 1) Pin plunger Fifth digit of part number O.F. max. R.F. min. P.T. max. M.D. max. O.T. min. O.P. max N 0.12N ± ± N 0.25N ± ± N 0.49N ± ± N 0.74N ± ± N 0.98N ± ±.024 2) Short hinge lever Fifth digit of part number O.F. max. R.F. min. P.T. max. M.D. max. O.T. min. O.P. max N 0.098N ± ± N 0.20N ± ± N 0.39N ± ± N 0.59N ± ± N 0.78N ± ±.031 3) Hinge lever Fifth digit of part number O.F. max. R.F. min. P.T. max. M.D. max. O.T. min. O.P. max N 0.049N ± ± N 0.098N ± ± N 0.20N ± ± N 0.29N ± ± N 0.39N ± ±

78 4) Long hinge lever Fifth digit of part number 5) Simulated roller lever 6) Short roller lever 7) Roller lever DIMENSIONS O.F. max. R.F. min. P.T. max. M.D. max. O.T. min. O.P. max N 0.025N ± ± N 0.049N ± ± N 0.098N ± ± N 0.15N ± ± N 0.39N ± ±.102 Fifth digit of part number O.F. max. R.F. min. P.T. max. M.D. max. O.T. min. O.P. max N 0.049N ± ± N 0.098N ± ± N 0.20N ± ± N 0.29N ± ± N 0.39N ± ±.047 Fifth digit of part number O.F. max. R.F. min. P.T. max. M.D. max. O.T. min. O.P. max N 0.098N ± ± N 0.20N ± ± N 0.39N ± ± N 0.59N ± ± N 0.78N ± ±.031 Fifth digit of part number O.F. max. R.F. min. P.T. max. M.D. max. O.T. min. O.P. max N 0.049N ± ± N 0.098N ± ± N 0.20N ± ± N 0.29N ± ± N 0.39N ± ± Pin plunger Bottom COM terminal (Guardless).187 Quick-connect/Solder terminal Solder terminal AH7 (P.T.) 1.6 max ± ± dia. hole dia. hole (P.T.) 1.6 max ± ± dia. hole dia. hole (O.P.) 14.7 ± ± (O.P.) 14.7 ± ± ± ± ± ± ± ± ± ± ± ± ± ±

79 AH7 Side COM terminal (with right-hand guard) Side COM terminal (Guardless).187 Quick-connect/Solder terminal (P.T.) 1.6 max ± ± dia. hole dia. hole (O.P.) 14.7 ± ± ± ± ± ± ± ± Short hinge lever (P.T.) 1.6 max ± ± (O.P.) 15.3 ± ± Hinge lever (P.T.) 3.2 max ± ± (O.P.) 15.3 ± ± Long hinge lever (P.T.) 7.5 max ± ± (O.P.) 15.3 ± ± Simulated roller lever (P.T.) 3.2 max..126 (O.P.) 18.5 ± ± ± ±.020 3R.118R

80 AH7 6. Short roller lever (P.T.) 1.6 max..063 (O.P.) 20.7 ± ± ± ± dia Roller lever (P.T.) 3.2 max ± ± (O.P.) 20.7 ± ± dia..189 NOTES 1. Use M3 screws to mount switches with less than a 0.49N m torque. Use of screw washers or adhesive lock is recommended. Before mounting, check insulation distance between terminals as well as between terminals and ground. If enough distance is not secured, it is recommended to use insulation material in mounting. Set 70 to 100% overtravel in actual use. When the operation object is in the free position, force should not be applied directly to the actuator or to the pin plunger. Also force should be applied to the pin plunger from vertical direction to the switch. 2. When specifying NV switches, allow ±20% to the listed operating and release forces. 3. Hand soldering should be accomplished in less than 5 seconds, preferably with a 60 watt iron. Avoid contacting the switch case with the soldering iron. 4. Low-level circuit type is recommended for using under low-level current and voltage. 5. Avoid using NV switches in the following conditions: In corrosive gases, such as hydrogen sulfide. In flammable or explosive gases such as gasoline or thinner etc. In a dusty environment. In an ambient temperature under 25 C 13 F or over 80 C 176 F. In an ambient humidity over 85% R.H.. 79

81 AV3,AVM3/AVT3,AVL3 NEW SUBMINIATURE SWITCHES WITH HIGH PRECISION VDE FS FS-T (AV) SWITCHES FS FS-T FEATURES New additions: FS-T Cross-line terminal types Gold-clad double layer types exclusively for low-level circuits Consistent quality and high precision through sophisticated automatic fabrication system O.P.: 8.4±0.3 mm.331±.012 inch (O.P.of conventional subminiature switches: 8.4± ±.020) Flux-resistant construction with integrally molded terminals Solder terminal; Self-standing, internationally common pitch, right angle, left angle terminals for PC board; Quick connect.110 terminals for easy mounting Insulation guard available for safety mounting 2 lever pivot positions available for applications where low operating force is required UL/CSA/VDE/SEMKO approved (As for gold-clad double layer, VDE and SEMKO are not approved) TYPICAL APPLICATIONS Communication equipment Vending machines Security systems Data systems Medical equipment Cassette tape recorders VCR PC board thickness: 1.6 mm.063 inch CONSTRUCTION (Example: AV3/AVM3 type) Standard version 2 lever pivot positions Spring Long life version Arch-shaped independent spring CONTACT ARRANGEMENT Solder-terminal Self-standing PC terminal.110 Quick connect terminal COM NO NC Optional insulation guard Flux resistant construction Remark: As for FS-T switches, the terminals are the different shape. 80

82 ORDERING INFORMATION 1.FS switches AV3,AVM3/AVT3,AVL3 Ex. AV Type of switch FS FS-T switch Version 3: Standard M3: Long life Terminals Actuators Operating force by pin plunger, max. Lever position Contacts 0: Pin plunger Standard version: Nil: Standard 1: Short hinge lever 0: 0.25 N [11: forward] 2: Hinge lever 2: 0.49 N 3: Long hinge lever 4: 0.98 N 4: Simulated roller lever 5: Roller lever 1: Self-standing solder terminal with guard 2: Self-standing solder terminal without guard 3: Self-standing solder terminal with opposite side guard 4: Self-standing PC terminal (5: Internationally common pitch PC terminal) (6: Right angle terminal) (7: Left angle terminal) 8:.110 Quick-connect terminal Long life version: 5: 1.47 N Nil: Standard type 61: Gold-clad triple layer 64: Gold-clad double layer type exlusively for low-level circuits 2.FS-T switches Ex. AV T Type of switch FS FS-T switch Version T3: Standard L3: Long life Terminals Actuators Operating force by pin plunger, max. Lever position Contacts 0: Pin plunger Standard version: Nil: Standard 1: Short hinge lever 0: 0.25 N [11: forward] 2: Hinge lever 2: 0.49 N 3: Long hinge lever 4: 0.98 N 4: Simulated roller lever Long life version: 5: Roller lever 5: 1.47 N 2: Solder terminal 4: PC terminal 8:.110 Quick-connect terminal Nil: Standard type (Not applicable to 0.25 N type) 61: Gold-clad triple layer 64: Gold-clad double layer type exlusively for low-level circuits APPLICABLE CURRENT RANGE Type Standard version Long life version Contact Silver alloy contact Gold-clad triple layer contact type Gold-clad double layer contact type Silver alloy contact Gold-clad triple layer contact type Gold-clad double layer contact type Rating 1mA 100mA 3A 5A 0.25 N 0.49 N Remark: For high capacity contact rating up to 10.1 A, please refer to PS (AVM3 P) switches catalog. O.F N 1.47 N Gold-clad double layer (64) Gold-clad triple layer (61) Au Au CuNi Ag CuNi 81

83 AV3,AVM3/AVT3,AVL3 PRODUCT TYPES 1.FS switches (In-line terminal type) Standard type Part No. Operating Self-standing solder terminal Actuator force,.110 Quickconnect Self-standing Max. With opposite Without guard With guard PC terminal side guard terminal Pin plunger 0.49 N AV3202 AV3102 AV3302 AV3402 AV N AV3204 AV3104 AV3304 AV3404 AV3804 Short hinge lever 0.20 N AV3212 AV3112 AV3312 AV3412 AV N AV3214 AV3114 AV3314 AV3414 AV N AV3222 AV3122 AV3322 AV3422 AV3822 Hinge lever Silver alloy contact 0.34 N AV3224 AV3124 AV3324 AV3424 AV3824 type 0.12 N AV3232 AV3132 AV3332 AV3432 AV3832 Long hinge lever 0.25 N AV3234 AV3134 AV3334 AV3434 AV3834 Simulated roller lever 0.16 N AV3242 AV3142 AV3342 AV3442 AV N AV3244 AV3144 AV3344 AV3444 AV3844 Roller lever 0.20 N AV3252 AV3152 AV3352 AV3452 AV N AV3254 AV3154 AV3354 AV3454 AV N AV AV AV AV AV Pin plunger 0.49 N AV AV AV AV AV N AV AV AV AV AV N AV AV AV AV AV Short hinge lever 0.20 N AV AV AV AV AV N AV AV AV AV AV N AV AV AV AV AV Gold-clad triple layer Hinge lever 0.16 N AV AV AV AV AV contact type 0.34 N AV AV AV AV AV Long hinge lever 0.12 N AV AV AV AV AV N AV AV AV AV AV Simulated roller lever 0.16 N AV AV AV AV AV N AV AV AV AV AV Roller lever 0.20 N AV AV AV AV AV N AV AV AV AV AV N AV AV AV AV AV Pin plunger 0.49 N AV AV AV AV AV N AV AV AV AV AV N AV AV AV AV AV Short hinge lever 0.20 N AV AV AV AV AV N AV AV AV AV AV Gold-clad double N AV AV AV AV AV layer type Hinge lever 0.16 N AV AV AV AV AV exclusively for low-level circuits 0.34 N AV AV AV AV AV Long hinge lever 0.12 N AV AV AV AV AV N AV AV AV AV AV Simulated roller lever 0.16 N AV AV AV AV AV N AV AV AV AV AV Roller lever 0.20 N AV AV AV AV AV N AV AV AV AV AV Remark: When ordering, please refer to Remarks of ordering information. 82

84 2.FS-T switches (Cross-line terminal type) Standard type Operating Actuator force, Max. Silver alloy contact type Gold-clad triple layer contact type Gold-clad double layer type exclusively for low-level circuits Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever Pin plunger Short hinge lever Hinge lever Long hinge lever Simulated roller lever Roller lever Solder terminal without guard AV3,AVM3/AVT3,AVL3 Part No. PC terminal.110 Quick-connect terminal 0.49 N AVT3202 AVT3402 AVT N AVT3204 AVT3404 AVT N AVT3212 AVT3412 AVT N AVT3214 AVT3414 AVT N AVT3222 AVT3422 AVT N AVT3224 AVT3424 AVT N AVT3232 AVT3432 AVT N AVT3234 AVT3434 AVT N AVT3242 AVT3442 AVT N AVT3244 AVT3444 AVT N AVT3252 AVT3452 AVT N AVT3254 AVT3454 AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT N AVT AVT AVT

85 AV3,AVM3/AVT3,AVL3 3.FS switches (In-line terminal type) Long life version Part No. Operating Self-standing solder terminal Actuator force,.110 Quickconnect Self-standing Max. With opposite Without guard With guard PC terminal side guard terminal Pin plunger 1.47 N AVM3205 AVM3105 AVM3305 AVM3405 AVM3805 Short hinge lever 0.59 N AVM3215 AVM3115 AVM3315 AVM3415 AVM3815 Silver alloy contact Hinge lever 0.54 N AVM3225 AVM3125 AVM3325 AVM3425 AVM3825 type Long hinge lever 0.44 N AVM3235 AVM3135 AVM3335 AVM3435 AVM3835 Simulated roller lever 0.54 N AVM3245 AVM3145 AVM3345 AVM3445 AVM3845 Roller lever 0.59 N AVM3255 AVM3155 AVM3355 AVM3455 AVM3855 Pin plunger 1.47 N AVM AVM AVM AVM AVM Short hinge lever 0.59 N AVM AVM AVM AVM AVM Gold-clad triple layer Hinge lever 0.54 N AVM AVM AVM AVM AVM contact type Long hinge lever 0.44 N AVM AVM AVM AVM AVM Simulated roller lever 0.54 N AVM AVM AVM AVM AVM Roller lever 0.59 N AVM AVM AVM AVM AVM Pin plunger 1.47 N AVM AVM AVM AVM AVM Short hinge lever 0.59 N AVM AVM AVM AVM AVM Gold-clad double layer type Hinge lever 0.54 N AVM AVM AVM AVM AVM exclusively for Long hinge lever 0.44 N AVM AVM AVM AVM AVM low-level circuits Simulated roller lever 0.54 N AVM AVM AVM AVM AVM Roller lever 0.59 N AVM AVM AVM AVM AVM Remark: When ordering, please refer to Remarks of ordering information. 4.FS-T switches (Cross-line terminal type) Long life version Operating Actuator force, Max. Solder terminal Without guard Part No. PC terminal.110 Quick-connect terminal Pin plunger 1.47 N AVL3205 AVL3405 AVL3805 Short hinge lever 0.59 N AVL3215 AVL3415 AVL3815 Silver alloy contact Hinge lever 0.54 N AVL3225 AVL3425 AVL3825 type Long hinge lever 0.44 N AVL3235 AVL3435 AVL3835 Simulated roller lever 0.54 N AVL3245 AVL3445 AVL3845 Roller lever 0.59 N AVL3255 AVL3455 AVL3855 Pin plunger 1.47 N AVL AVL AVL Short hinge lever 0.59 N AVL AVL AVL Gold-clad triple layer Hinge lever 0.54 N AVL AVL AVL contact type Long hinge lever 0.44 N AVL AVL AVL Simulated roller lever 0.54 N AVL AVL AVL Roller lever 0.59 N AVL AVL AVL Pin plunger 1.47 N AVL AVL AVL Short hinge lever 0.59 N AVL AVL AVL Gold-clad double layer type Hinge lever 0.54 N AVL AVL AVL exclusively for Long hinge lever 0.44 N AVL AVL AVL low-level circuits Simulated roller lever 0.54 N AVL AVL AVL Roller lever 0.59 N AVL AVL AVL Remark: When ordering, please refer to Remarks of ordering information. 84

86 SPECIFICATIONS 1.Contact rating Voltage Silver alloy contact type Resistive load (cosφ]1) Standard version Inductive load (cosφ] ) Remark: Time constant shall be less than 7 msec. for DC inductive loads. AV3,AVM3/AVT3,AVL3 Long life version Gold-clad contact type Gold-clad contact type Silver alloy contact type Triple layer Double layer Triple layer Double layer Resistive load (cosφ]1) Resistive load (cosφ]1) Resistive load (cosφ]1) Inductive load (cosφ] ) Resistive load (cosφ]1) Resistive load (cosφ]1) 125V AC 3A 2A 0.1A 5A 3A 0.1A 250V AC 3A 2A 0.1A 5A 3A 0.1A 30V DC 3A 2A 0.1A 0.1A 5A 3A 0.1A 0.1A 125V DC 0.4A 0.05A 0.4A 0.05A 2.Characteristics Standard version Long life version Silver alloy contact type Gold-clad contact type Silver alloy contact type Gold-clad contact type Electrical life at rated load (O.T.max.) at 20 cpm at 20 cpm at 20 cpm at 20 cpm Mechanical life at 60 cpm (O.T.max.) (O.T.: Specified value) 10 7 (O.T.max.) at 60 cpm Insulation resistance Min.100MΩ at 500V DC Dielectric strength Between non-continuous terminals Between each terminal and other exposed metal parts Between each terminal and ground Vibration resistance (Pin plunger type) Shock resistance (Pin plunger type) (Contact opening: less than 1 msec.) Contact resistance (Initial) Allowable operating speed Max.operating cycle rate Ambient temeprature Unit weight 294 m/s 2 min. (O.F N) 147 m/s 2 min. (O.F N) 50 mω max. (by voltage drop 1 A 6 to 8V DC) 1,000 Vrms 1,500 Vrms 1,500 Vrms 10 to 55 Hz at single amplitude of 1.5mm (Contact opening: max.1 msec.) 294 m/s 2 min. (O.F N) 147 m/s 2 min. (O.F N) 49 m/s 2 min. (O.F N) 100 mω max. (by voltage drop 0.1 A 6 to 8V DC) 3.Operating characteristics 1) Pin plunger 4th digit number of O.F.max. R.F.min. P.T.max. M.D.max. O.T.max. O.P. Part No N 0.020N 294 m/s 2 min. Au: 50 mω max. (by voltage drop 0.1 A 6 to 8V DC) Ag: 50 mω max. (by voltage drop 1 A 6 to 8V DC) 0.1 to 1,000 mm/sec. 300 cpm 25 C to +85 C 13 F to +185 F (no freezing below 0 C) Approx.2g.07oz N 0.074N N 0.15N 0.6mm.024inch 0.1mm.004inch 0.4mm.016inch Distance from mounting holes: 8.4±0.3mm.331±.012inch Distance from stand-off: FS 11.8±0.4mm.465±.016inch FS-T 11.7±0.4mm.461±.016inch N 0.20N 2) Short hinge lever 4th digit number of O.F.max. R.F.min. P.T.max. M.D.max. O.T.max. O.P. Part No N 0.004N N 0.017N N 0.034N 2.5mm.098inch 0.5mm.020inch 0.8mm.031inch Distance from mounting holes: 8.8±0.8mm.346±.031inch Distance from stand-off: FS 12.2±0.9mm.480±.035inch FS-T 12.1±0.9mm.476±.035inch N 0.039N 85

87 AV3,AVM3/AVT3,AVL3 3) Hinge lever 4th digit number of Part No. O.F.max. R.F.min. P.T.max. M.D.max. O.T.max. O.P N 0.003N N 0.015N N 0.029N 2.8mm.110inch 0.8mm.031inch 1.2mm.047inch Distance from mounting holes: 8.8±0.8mm.346±.031inch Distance from stand-off: FS 12.2±0.9mm.480±.035inch FS-T 12.1±0.9mm.476±.035inch N 0.034N 4) Long hinge lever 4th digit number of O.F.max. R.F.min. P.T.max. M.D.max. O.T.max. O.P. Part No N 0.012N N 0.025N 3.5mm.138inch 1.0mm.039inch 1.6mm.063inch Distance from mounting holes: 8.8±1.2mm.346±.047inch Distance from stand-off: FS 12.2±1.3mm.480±.051inch FS-T 12.1±1.3mm.476±.051inch N 0.029N 5) Simulated roller lever 4th digit number of O.F.max. R.F.min. P.T.max. M.D.max. O.T.max. O.P. Part No N 0.015N N 0.029N 2.8mm.110inch 0.8mm.031inch 1.2mm.047inch Distance from mounting holes: 11.65±0.8mm.459±.031inch Distance from stand-off: FS 15.05±0.9mm.593±.035inch FS-T 14.95±0.9mm.589±.035inch N 0.034N 6) Roller lever 4th digit number of Part No. O.F.max. R.F.min. P.T.max. M.D.max. O.T.max. O.P N 0.017N N 0.034N 2.5mm.098inch 0.5mm.020inch 0.8mm.031inch Distance from mounting holes: 14.5±0.8mm.571±.031inch Distance from stand-off: FS 17.9±0.9mm.705±.035inch FS-T 17.8±0.9mm.701±.035inch N 0.039N General tolerance: ±0.25 ±.010 DIMENSIONS 1.FS switches (In-line terminal type) 1-(1) Self-standing solder terminal PC board pattern Pin plunger 7.6 ± ± (P.T.) 0.6 max ±0.05 dia ±.002 dia C NO ± ±.004 ± ±.004 ± ± ± ±.006 ± ±.012 NC (O.P.) ± (O.P.) ± ± ± ± ± ± ± dia dia ± ± ± ± ±0.12 ± ± ± ±0.2 ±.008 Pretravel, Max Movement differential, Max Overtravel, Min Operating position 8.7 ± ± ± ±.004 Distance from mounting hole, Distance from standoff, 8.4± ± ± ±

88 AV3,AVM3/AVT3,AVL3 Short hinge lever General tolerance ±0.25 ±.010 ±0.4 (P.T.) ± max C NO NC (O.P.) ± ±.031 (O.P.) ± ±.035 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from standoff, 8.8± ± ± ±.035 Hinge lever (P.T.) 7.15 ±0.4 ± max C NO NC (O.P.) ± ±.031 (O.P.) ± ±.035 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from standoff, 8.8± ± ± ±.035 Long hinge lever (P.T.) 3.5 max ± ± C NO NC (O.P.) ± (O.P.) ± ± ±.035 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from standoff, 8.8± ± ± ±.051 Simulated roller lever 6.3 (P.T.) ±0.4 ± max..110 R C NO NC (O.P.) ± (O.P.).459 ± ± ±.035 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from standoff, 11.65± ± ± ±.035 Roller lever (P.T.) 5.15 ± max. ± dia..197 C NO NC (O.P.) Pretravel, Max ± (O.P.).571 ±.031 ± Movement differential, Max ±.035 Overtravel, Min Operating position Distance from mounting hole, Distance from standoff, 14.5± ± ± ±

89 AV3,AVM3/AVT3,AVL3 1-(2) Self-standing solder terminal (without guard) General tolerance ±0.25 ± ±0.15 ±.006 C NO NC ± ±.005 ± ± ±0.2 ± ±0.15 ± ± ±.008 ± ± ± ±.004 ± ±.012 Dimensions other than drawn above is same as self-standing PC board terminal. 1-(3) Self-standing solder terminal (with guard) ± ±.008 C NO NC Dimensions other than drawn above is same as guardless type. 1-(4) Self-standing solder terminal (with opposite side guard) Dimensions other than drawn above is same as guardless type. 1-(5).110 Quick-connect terminal ±0.15 ± ± ±.004 ± dia. ± dia. C 2.5 ± ± ±.006 NO ±.004 ± ± ± ±0.1 ± ±.012 Dimensions other than drawn above is same as self-standing PC board terminal. NC 6-C0.6 ±0.1 6-C.024 ± ± ±0.15 ±.006 ± ± ± FS-T switches (Cross-line terminal type) 2-(1) PC board terminal Pin plunger C 2.5 ± ±.004 NO ± (P.T.) max ± ± ±.004 ± ±.012 NC (O.P.) ± ± dia dia. 6.4 ± ± ± ± to 1.50 dia to.059 dia. PC board pattern ±0.1 (Button position).346 ± ± ±.004 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from standoff, 8.4± ± ± ±.016

90 AV3,AVM3/AVT3,AVL3 Short hinge lever General tolerance ±0.25 ± ±0.4 (P.T.) ± max C NO NC (O.P.) ± ±.031 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from standoff, 8.8± ± ± ±.035 Hinge lever ±0.4 (P.T.).281 ± max C NO NC (O.P.) ± ±.031 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from standoff, 8.8± ± ± ±.035 Long hinge lever (P.T.) ± max ± C NO NC (O.P.) ± ±.047 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from standoff, 8.8± ± ± ±.051 Simulated roller lever (P.T.) 6.3 ± max. ± R C NO NC (O.P.) ± ±.031 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from standoff, 11.65± ± ± ±.035 Roller lever (P.T.) 5.15 ± max. ± dia..197 C NO NC (O.P.) ± ±.031 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, Distance from standoff, 14.5± ± ± ±

91 AV3,AVM3/AVT3,AVL3 2-(2) Self-standing solder terminal General tolerance ±0.25 ± ± ±.012 (P.T.) 0.6 max C 2.5 ± ±.004 NO ± ± ± ±.012 NC (O.P.) ± ± dia dia. 1.8 dia..071 dia. 6-C C ± ±.008 (3.9) (.154) ± ±.008 As for the dimensions of lever types, dimensions other than terminals are same as self-standing solder terminal. 2-(3).110 Quick-connect terminal 7.6 ± ±.012 (P.T.) 0.6 max (O.P.) ± ± C 2.5 ± ±.004 NO NC dia dia. 5.5 ± ±.004 ± ± ± ± ± ± ± ± ± ±.008 ± dia. ± dia. As for the dimensions of lever types, dimensions other than terminals are same as self-standing solder terminal. 90

92 NOTES 1.Regarding fastening of switch body In fastening the switch body, use flat filister head M2.3 screws, with tightening torque of not more than 0.29N m.to prevent loosening of the screws, it is recommended that spring washers be used with the screws and adhesive be applied to lock the screws. After mounting the switch and making wiring connectors, the insulation distance between ground and each terminal should be confirmed as sufficient. The positioning of the switch should be such that the pushbutton or actuator for the switch should not directly apply force to the operating section in the free condition.for a pushbutton, the force from the pushbutton should be applied in a perpendicular direction. In setting the movement after operation, the over-travel should be set not less than 70% as a standard.setting the movement at less than 70% of O.T.may cause troubles such as mis-contact and welding due to small contact force of the switch. N.C. side Contact force N.O. side 0 P.T. 70% of O.T. specified value Usable area O.T. spedified value O.T. max. Stroke 2.Soldering operation For manual soldering: 60W soldering iron, soldering completed within 3 seconds; do not apply force to the terminals. For automatic soldering tank: 250 C +482 F immersion, completed within 6 seconds, 350 C +662 F immersion, completed within 3 seconds. Terminal portions must not be moved in min.1 minutes after soldering.also no tensile strength of lead wires should be applied to terminals. 3.Regarding connector connections (.110 quick connect terminals) For making connections, a dedicated receptacle for.110 quick connect terminals should be used, and the terminals should be inserted parallel to the receptacle.consideration should be given to mounting so that no tensile load is applied to the lead wires. 4.In making the switch selection Consideration should be given to provide for no interference up to +20% variation of the standard characteristics values. 5.Environment Locations where corrosive gases having a bad influence on contacts are present, and locations where there is an excessive amount of siliceous or other abrasive dust should be avoided. AV3,AVM3/AVT3,AVL3 6.Cautions regarding use This subminiatures switch has been designed as a dedicated switch for AC use, but it can be used for low capacity DC circuits. Please select gold-clad contact types when loads are in the low-level area of 1mA up to 100mA and 5V up to 30V. 3 A 100 ma 1 ma 0 DC AC 5 5 For switching of inductive loads (relays, solenoids, buzzers, etc.), in order to prevent damage to contacts due to the occurrence of arcing, an arc absorbing circuit should be applied 7.Quality check under Actual Loading Condition To assure reliability, check the switch under actual loading conditions.avoid any situation that may adversely affect switching performance. 8.When using lever type switch, care should be taken not to apply undue force on the body from the opposite side or side ways to its operating direction. Ag Au (-61) Triple layer contact type Au (-64) Double layer contac type 15 30V V 91

93 AV3 G SUBMINIATURE SWITCHES (Contact gap: more than 1mm.039inch type) VDE FS (AV3 G) SWITCHES FEATURES Conforming to IEC950 Contact gap of greater than 1mm.039inch UL/CSA/VDE/SEMKO under application TYPICAL APPLICATIONS Office equiment (printers, copiers) ORDERING INFORMATION Ex. AV G Type of switch FS switch Version 3: Standard Terminals 2: Self-standing solder terminal without guard 4: Self-standing PC terminal 8:.110 Quick-connect terminal Actuators 0: Pin plunger 1: Short hinge lever 2: Hinge lever 3: Long hinge lever 4: Simulated roller lever 5: Roller lever Operating force by pin plunger, max. 5: 1.47 N Contact gap G: More than 1 mm type PRODUCT TYPES Actuator Operating force Solder terminal Max. Without guard PC board terminal.110 Quick- connect terminal Pin plunger 1.47 N AV3205G3 AV3405G3 AV3805G3 Short hinge lever 0.59 N AV3215G3 AV3415G3 AV3815G3 Hinge lever 0.54 N AV3225G3 AV3425G3 AV3825G3 Long hinge lever 0.44 N AV3235G3 AV3435G3 AV3835G3 Simulated roller lever 0.54 N AV3245G3 AV3445G3 AV3845G3 Roller lever 0.59 N AV3255G3 AV3455G3 AV3855G3 Remark: Unless you request otherwise, the switch comes with a stamp indicating its conformance to standards. SPECIFICATIONS 1. Contact rating Silver alloy contact type Voltage Resistive road (cos φ]1) 30 V DC 3 A 92

94 Remark: Test conditions are in accordance with JIS C AV3 G 2. Characteristics Item Characteristics Expected life Mechanical (O.T.: Specified value) Min (at 60cpm) Electrical (O.T. max.) Min (at 20cpm) Between non-continuous terminals 1,000 Vrms for 1 min. (at 10mA) Breakdown voltage Between each terminal and other exposed metal parts 2,000 Vrms for 1 min. (at 10mA) Between each terminal and ground 2,000 Vrms for 1 min. (at 10mA) Insulation resistance Min. 100MΩ (at 500 V DC) Contact resistance (Initial) Max. 50mΩ (by voltage drop 6 to 8 V DC 1A) Vibration resistance 10 to 55 Hz at single amplitude of 0.75 mm (Contact opening: Max. 1 msec.) Shock resistance Pin plunger type 294m/s 2 (Contact distance: Max. 1 msec.) Lever type 147m/s 2 (Contact distance: Max. 1 msec.) Allowable operation speed (No load) 0.1 to 1,000 mm/s Max. switching frequency (No load) 300 cpm. Ambient temperature 25 C to +85 C 13 F to +185 F (Not freezing below 0 C 32 F) 3. Operating characteristics Actuator Operating force, Max. Release force, Min. Pin plunger 1.47 N N Short hinge lever 0.59 N N Hinge lever 0.54 N N Long hinge lever 0.44 N N Simulated roller lever 0.54 N N Roller lever 0.59 N N Pretravel, Max Movement differential, Max Overtravel, Min Operating position, 8.4± ± ± ± ± ± ± ± ± ± ± ±.031 DIMENSIONS The same size as the standard FS/FS-T switches. Please refer to FS/FS-T switches pages or our web site. URL: 93

95 AVM3 P HIGH CAPACITY, LONG LIFE SUBMINIATURE SWITCH PS (AVM3 P) SWITCHES FEATURES 10.1 Amp. high contact capacity is available Long life Precise operating position (±0.25mm: Pin plunger type) Flux-resistant construction with integrally molded terminals In-line terminals make soldering works easy UL/CSA/SEMKO approved TYPICAL APPLICATIONS Heaters Electric carpets Electric rice cookers Copiers Printers Facsimiles Vending machines Measuring equipment Audio equipment ORDERING INFORMATION Ex. AVM P Type of switch PS switch Terminals 1: Self-standing solder terminal with guard 2: Self-standing solder terminal without guard 3: Self-standing solder terminal with opposite side guard 4: Self-standing PC terminal Actuators 0: Pin plunger 1: Short hinge lever 2: Hinge lever 3: Long hinge lever 4: Simulated roller lever 5: Roller lever Operating force by pin plunger, max. 5: 1.47 N Remarks: When ordering UL/CSA/SEMKO approved types, add suffix 3 to the part No., for example, AVM3205P3. Capacity P: High capacity (10.1 A) CONSTRUCTION ; COM CONTACT ARRANGEMENT: SPST NO NC DATA Electrical life curve No. of operations, Load current (A) 94

96 PRODUCT TYPES Contact Gold-clad Remarks: When ordering UL/CSA/SEMKO approved types, add suffix 3 to the part No., for example, AVM3205P3. SPECIFICATIONS 1. Contact rating Resistive load (cos φ ] 1) Actuator 2. Characteristics Electrical Expected life Mechanical Between terminals Dielectric Between terminals and other exposed metal parts strength Between terminals and ground Insulation resistance Contact resistance (initial) Allowable operating speed (at no load) Max. operating cycle rate (at no load) Ambient temperature Unit weight 3. Operating characteristics Operating force, Actuator Max. Without guard Part No. Self-standing solder terminal With guard With opposite side guard AVM3 P Self-standing PC terminal Pin plunger AVM3205P AVM3105P AVM3305P AVM3405P Short hinge lever AVM3215P AVM3115P AVM3315P AVM3415P Hinge lever AVM3225P AVM3125P AVM3325P AVM3425P Long hinge lever AVM3235P AVM3135P AVM3335P AVM3435P Simulated roller lever AVM3245P AVM3145P AVM3345P AVM3445P Roller lever AVM3255P AVM3155P AVM3355P AVM3455P Release force, Min. Pin plunger 1.47 N 0.20 N Short hinge lever 0.59 N N Hinge lever 0.54 N N Long hinge lever 0.44 N N Simulated roller lever 0.54 N N Roller lever 0.59 N N Pretravel, Max. 0.6 mm.024 inch 2.5 mm.098 inch 2.8 mm.110 inch 3.5 mm.138 inch 2.8 mm.110 inch 2.5 mm.098 inch 10.1A, 250V AC Min (at 20 cpm) (O.T. max.) Min (O.T.: Specified value), at 60 cpm 1,000 Vrms for 1 min. (at 10 ma) 2,000 Vrms for 1 min. (at 10 ma) 2,000 Vrms for 1 min. (at 10 ma) Min. 100MΩ (at 500V DC) Max. 50mΩ (By voltage drop, 1A 6 to 8V DC) 0.1 to 1,000 mm/sec. 300 cpm 25 to +85 C 13 to +155 F (Not freezing below 0 C 32 F) Approx. 2g.07oz Movement differential, Max. 0.1 mm.004 inch 0.5 mm.020 inch 0.8 mm.031 inch 1.0 mm.039 inch 0.8 mm.031 inch 0.5 mm.020 inch Overtravel, Min. 0.4 mm.016 inch 0.8 mm.031 inch 1.2 mm.047 inch 1.6 mm.063 inch 1.2 mm.047 inch 0.8 mm.031 inch Operating position 8.4±0.25 mm.331±.010 inch 8.8±0.8 mm.346±.031 inch 8.8±0.8 mm.346±.031 inch 8.8±1.2 mm.346±.047 inch 11.65±0.8 mm.459±.031 inch 14.5±0.8 mm.571±.031 inch General tolerance: ±0.25 ±.010 DIMENSIONS 1. Self-standing PC terminal (Without guard) Pin plunger PC board pattern ± dia. ± dia C 7.6 ±0.3 ± NO NC (P.T.) 0.6 max..024 (O.P.) 3.4 ± ±.006 (O.P.) ± ±.010 ± ± ±0.12 ± ± ±0.12 ±.005 ± ± ±.006 Pin plunger position ( ) 15.4 ± ± ± ±.004 ±0.15 ± ± ±.006 ± ± ± ± ± ± dia dia ± ± ± ±.004 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, 8.4± ±

97 AVM3 P Short hinge lever General tolerance: ±0.25 ± (P.T.) 2.5 max. 5.0 ± ± C NO 2.5 ± ±.004 ± ±.006 ± ± ± ±.004 ± ± NC (O.P.) ± (O.P.) ± ± ± ± ±.004 ± ± ± ±0.12 ± ± ±0.12 ±.005 ± dia dia..020 Pretravel, Max ± Movement differential, ±.004 Max Overtravel, Min ±0.2 Operating position Distance from mounting hole, 8.8± ±.031 Hinge lever ±0.4 ± (P.T.) 2.8 max NO C NC ± ±.004 ± ±.006 ± ± ± ±.004 ± ± (O.P.) ± (O.P.) ± ± ± ± ±.004 ± ± dia dia ± ± ±0.12 ± ±0.12 ±.005 ± ± ±0.2 ±.008 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, 8.8± ±.031 Long hinge lever ±0.4 ± (P.T.) 3.5 max NO C NC ± ±.004 ± ± ± ±.006 ± ±.006 ± ± ± ± ± ±.004 (O.P.) 8.8 ±1.2 (O.P.) ± ± ± dia dia ± ± ±0.12 ± ±0.12 ±.005 ± ± ±0.2 ±.008 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, 8.8± ±

98 AVM3 P Simulated roller lever General tolerance: ±0.25 ± ±0.4 ± R (P.T.) 2.8 max NO C NC ± ±.004 ± ±.006 ± ± ± ±.004 ± ± ± ± ± ±.004 (O.P.) ±0.8 (O.P.) ± dia dia. ± ± ± ± ±0.12 ± ±0.12 ±.005 ± ± ±0.2 ±.008 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, 11.65± ±.031 Roller lever ± ±.016 (P.T.) 2.5 max dia C NO 2.5 ± ±.004 ± ±.006 ± ± ± ±.004 ± ± NC ± ±.004 (O.P.) 14.5 ±0.8 (O.P.) ± ± ± dia dia. ± ± ± ± ±0.12 ± ±0.12 ±.005 ± ± ±0.2 ±.008 Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, 14.5± ± Self-standing solder terminal Pin plunger With guard With opposite side guard C ± NO ± ±.004 ± ±.004 ±0.15 ± ±.006 ± ± NC R ± ± ± ±.012 R (P.T.) 0.6 max..024 (O.P.) ± (O.P.) ± ± ±.006 ± ± dia dia ± ± ±0.12 ± ±0.12 ±.005 ± ± ±0.2 ± * *.315 * The height from the center of mounting hole to the edge of guard. 97

99 AVM3 P NOTES 1. Fastening of the switch body 1) Use flat filister head M2.3 screws to mount switches with less than a 0.29 N m torque. Use of screws washers or adhesive lock is recommended to prevent loosening of the screws. 2) Check insulation distance between ground and each terminal. 3) When the operation object is in the free position, force should not be applied directly to the actuator or pin plunger from vertical direction to the switch. 4) In setting the movement after operation, the over-travel should be set more than 70% as a standard. Setting the movement at less than 70% of O.T. may cause troubles such as miscontact and welding due to small contact force of the switch. 5) For a lever type, the force from the reverse and side to the operation direction should not be applied. 2. Soldering operations For manual soldering: Soldering should be accomplished in less than 3 seconds, with a 60 watt iron. Care should be taken not to apply force to the terminal during soldering. For automatic soldering: Soldering should be done less than 6 seconds in 260 C 500 F soldering bath or less than 3 seconds in 350 C 662 F soldering bath. Terminal portions should not be moved within 1 minute after soldering. Also no tensile strength of lead wires should be applied to the terminals. 3. Selection of the switch When specifying the switch, allow ±20% to the listed operating characteristics. 4. Environment Avoid using the switches in the following conditions; In corrosive gases, such as silicon gas In a dusty environment 5. Cautions regarding use When switching low-level circuits (6V DC 5mA, 12V DC 2mA, 24V DC 1mA), FS/ FS-T Au clad contact type switches are recommended. When used to switch inductive loads (relays, solenoids, buzzers, etc.), it is recommended that a proper spark quench circuit is inserted in the switch to prevent contact faults caused by electric arcs. Care should be taken that occurrence in AC load possibly shorten the expected life. 6. Quality check under actual loading conditions To assure reliability, check the switch under actual loading conditions. Avoid any situation that may adversely affect switching performance. 98

100 AV6 S Model Switch Connector Type FEATURES Using a connector for connections significantly improves operation effectiveness. Applicable connector: XA connector produced by JST Mfg. Co., Ltd. - Contact: SXA-001T-P0.6 - Housing: XAP-02V-1 CS (AV6) SWITCHES The lever position is available in two types. Standard lever position "Standard lever position" refers to a position in which the lever is installed with the plunger close to the reference. Connector Contact reliability is achived by simple dust prevension guard and gold-clad double layer contacts Backward lever position "Backward lever position" refers to a position in which the lever is installed with the plunger far away from the reference. (with cap removed) A A A-A cross-section (internal parts omitted) Gold clad double layer contacts Gold-clad Copper alloy (SPST-NC) The contact arrangement is available in two types, the SPST-NC and the SPST-NO. TYPICAL APPLICATIONS Detection of vending machine condition whether cans are out of stock Ball detection of pinball game machine PPC (Plain Paper Copier) LBP (Laser Beam Printer) ORDERING INFORMATION Ex. AV Type of switch AV6: CS switch Contact arrangement 2: SPST-NC 3: SPST-NO Actuators 0: Pin plunger 2: Hinge lever 4: Simulated roller lever 5: Roller lever O.F. (by pin plunger) 2: 0.50 N 5: 1.50 N Remarks: 1. Standard packing Inner carton: 100 pcs. Outer carton: 1,000 pcs. 2. When ordering UL, CSA and TÜV approved types, please attach suffix 3 to the part no. Lever position Nil: Standard 12: Backward Contacts 64: Gold clad double layer 99

101 AV6 PRODUCT TYPES 1. Lever position: Standard Pin plunger Hinge lever Actuator Simulated roller lever Roller lever Operating force, Max. SPST-NC Remarks: 1. When ordering UL, CSA and TÜV approved (under application) types, please attach suffix "3" to the part no. Contact arrangement SPST-NO 0.50N AV AV N AV AV N AV AV N AV AV N AV AV N AV AV N AV AV N AV AV Lever position: Backward Hinge lever Actuator Simulated roller lever Roller lever Operating force, Max. Contact arrangement SPST-NC SPST-NO 0.35N AV AV N AV AV N AV AV N AV AV N AV AV N AV AV Remarks: 1. When ordering UL, CSA and TÜV approved (under application) types, please attach suffix "3" to the part no. SPECIFICATIONS 1. Contact rating Contact Voltage Resistive load (cos φ ] 1) Gold clad double layer 30[V] DC 0.1[A] 5[V] DC 1[mA] Low-level circuit rating 2. Characteristics Mechanical Expected life Electrical (Rated load) Insulation resistance Between terminals Dielectric strength Contact resistance (initial) Viblation resistance Shock resistance Between terminals and other exposed metal parts Between terminals and ground Connector insertion force Connector holding force Connector removal operating times Allowable operating speed (No load) Max. operating cycle rate (No load) Ambient temperature Unit weight Min (at 60 cpm) (O.T. max.) Min (at 20 cpm) (O.T. max.) Min. 100MΩ 1,000 Vrms for 1 min. 1,500 Vrms for 1 min. 1,500 Vrms for 1 min. 100MΩ max. (by voltage drop 0.1A 6 to 8 VDC) Value includes the resistance between the connector and the lead (#AWG28, length: 50 mm 1.969inch) 10 to 55 Hz at single amplitude of 0.75mm (Contact opening: max. 1msec.) Applied shock 1.50N type: Min.300m/s 2 {Contact opening: Max. 1msec.} 0.50N type: Min.150m/s 2 {Contact opening: Max. 1msec.} Max. 20N (inserted in removal direction) Min. 20N (extracted by static load, in removal direction) Max. 5 times (in removal direction) 0.1 to 1,000 mm/s (at pin plunger) 300 cpm 25 to +85 C 13 to +185 F (No freezing and condensing) Approx. 2.5g.09oz (pin plunger type) 100

102 3. Operating characteristics 1) Lever position: Standard Type of actuator Pin plunger Hinge lever Simulated roller lever Roller lever Operating force, Max. 2) Lever position: Backward Type of actuator Hinge lever Simulated roller lever Roller lever Release force, Min. Pretravel, Max. 0.50N 0.04N N 0.25N N 0.02N N 0.06N N 0.02N N 0.06N N 0.02N N 0.06N.102 Operating force, Max. Release force, Min. Pretravel, Max. 0.35N 0.03N N 0.10N{ N 0.03N N 0.10N N 0.03N N 0.10N.055 Movement differential, Max, Overtravel, Min. AV6 Operating position, General tolerance: ±0.25 ±.010 DIMENSIONS 1. Pin plunger Movement differential, Max, Overtravel, Min ± ± ± ± ± ± ± ±.031 Operating position, 9.2± ± ± ± ± ±.024 Pin plunger type P.T max. Pin plunger 2.4 type O.P ± ±.012 Base line ± ± ± ± Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, 8.4± ± Hinge lever Lever position: Standard ± ± ± ± P.T max. O.P 10.0 ± ± Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, 10.0± ±.031 Lever position: Backward P.T max. O.P 9.2 ± ± ± ± ± ± Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, 9.2± ±

103 AV6 3. Simulated roller lever Lever position: Standard General tolerance: ±0.25 ± ± ± ± ± P.T max. O.P 12.2 ± ± Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, 12.2± ±.031 Lever position: Backward P.T max. O.P 11.3 ± ± ± ± ± ± Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, 11.3± ± Roller lever Lever position: Standard P.T max ± ± ± ± O.P 15.7 ± ± Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, 15.7± ±.031 Lever position: Backward P.T max. O.P 14.9 ± ± ± ± ± ± Pretravel, Max Movement differential, Max Overtravel, Min Operating position Distance from mounting hole, 14.9± ±

104 NOTES 1. Fastening of the switch body 1) Use flat filister head M2.3 screws to mount switches with less than a 0.29N m torque. Use of screws washers or adhesive lock is recommended to prevent loosening of the screws. 2) Check insulation distance between ground and each terminal. 3) When the operation object is in the free position, force should not be applied directly to the actuator or pin plunger. Also force should be applied to the pin plunger from vertical direction to the switch. 4) In setting the movement after operation, the over-travel should be set more than 70% as a standard. With the lever type, do not apply excessive force in the direction opposite to the movement, or from the horizontal direction. 5) For a lever type, the force from the reverse to the operation direction should not be applied. 2. About the connector 1) The connector on the CS switch is designed to fit with the XA connector produced by JST Mfg. Co., Ltd. Do not use any connector other than the specified connector, or solder the terminals directly. 2) Make sure leads are arranged so that no constant force is applied to them when the connectors are mated. 3) Keep the connector straight when inserting it. If it is inserted at an angle, it may snag near the entrance, or it may be inserted too forcefully. 4) Problems thought to be caused by the XA connector, which is specified as conforming to the CS switch connector, are not covered by the warranty. Please contact JST Mfg., Co., Ltd. and request cooperation in resolving the problem. 3. Selection of the switch When specifying the switch, allow ±20% to the listed operating characteristics. AV6 4. Environment Avoid using the switches in the following conditions; In corrosive gases, such as silicon gas In a dusty environment When cleaning the switch, use a diluted form of a neutral cleaning agent. Using acidic or alkali solvents can adversely affect the performance of the switch. 5. Precautions concerning circuits The CS switch is designed specifically for low-voltage, low-current loads. Avoid using it at loads that exceed the resistive load. 6. Quality check under actual loading conditions To assure reliability, check the switch under actual loading conditions. Avoid any situation that may adversely affect switching performance. 103

105 AH1 ULTRA-MINIATURE SWITCHES WITH HIGH PRECISION FJ (AH1) SWITCHES FEATURES Integrally molded terminal block prevents soldering flux from entering into housing Compact size minimizes size of equipment Flat terminal shape makes soldering works easy Low-level circuit type available Self-standing PC board terminal type available TYPICAL APPLICATIONS Mouse Charger unit for mobile phone Detection of key position for automobiles Light angle terminal Left angle terminal ORDERING INFORMATION Ex. AH Product Name Terminal Operating force by Contact Actuator Contact pin plunger (max.) arrangement 4: 2.0 mm Self-standing PC board terminal with stand off 6: 1.47 N with stand off 0: Pin plunger 2: Hinge lever Nil: Silver alloy 61: Gold-clad Nil: SPDT A: SPST-NO FJ 6: 2.0 mm solder terminal with stand off 7: 2.0 mm PC board right angle terminal 8: 2.0 mm PC board left angle terminal 8: 0.74 N with stand off 4: Simulated roller lever Remark: 2.0 mm PC board terminal straight type is available. For details, please consult us. PRODUCT TYPES The color of: Color Type Body Cap Plunger Standard Black Black White Low-level circuit Black Black Red 1. Self-standing PC board terminal Actuators Operating force, Max. Standard (Silver alloy contact) Low-level circuit (Gold-clad contact) SPDT SPST-NO SPDT Pin plunger 0.74 N AH1480 AH1480A AH N AH1460 AH1460A AH Hinge lever 0.25 N AH1482 AH1482A AH N AH1462 AH1462A AH Simulated roller lever 0.26 N AH1484 AH1484A AH N AH1464 AH1464A AH Solder terminal Actuators Operating force, Max. Standard (Silver alloy contact) Low-level circuit (Gold-clad contact) SPDT SPDT Pin plunger 0.74 N AH1680 AH N AH1660 AH Hinge lever 0.25 N AH1682 AH N AH1662 AH Simulated roller lever 0.26 N AH1684 AH N AH1664 AH

106 AH1 3. PC board terminal right angle Actuators Operating force, Max. Standard (Silver alloy contact) Low-level circuit (Gold-clad contact) SPDT SPDT Pin plunger 0.74 N AH1780 AH Pin plunger 1.47 N AH1760 AH Hinge lever 0.25 N AH1782 AH Hinge lever 0.49 N AH1762 AH Simulated roller lever 0.26 N AH1784 AH Simulated roller lever 0.54 N AH1764 AH PC board terminal left angle Actuators Operating force, Max. Standard (Silver alloy contact) Low-level circuit (Gold-clad contact) SPDT SPDT Pin plunger 0.74 N AH1880 AH N AH1860 AH Hinge lever 0.25 N AH1882 AH N AH1862 AH Simulated roller lever 0.26 N AH1884 AH N AH1864 AH Remarks: 1. The appearance of right and left angle types are as below. Right angle Left angle 2. When ordering UL/CSA approved types, please attach suffix 9 to the part number. 3. Standard packing: 50 pcs./tube. 4. Please consult us for the delivery schedule of PC board terminal SPST-NO type. APPLICABLE CURRENT RANGE Contact Applicable current range Max. operating force for operation (at pin plunger) 1 ma 0.1 A 1 A 3 A 0.74 N 1.47 N Standard type (Silver alloy) Low level circuit type (Gold-clad) SPECIFICATIONS 1. Contact rating (resistive load) Standard rating Minimum rating O.F. 75g 2.65oz 1A 125V AC, 1A 30V DC Standard type O.F. 150g 5.29oz 3A 125V AC, 2A 30V DC Low-level circuit type 0.1A 125V AC, 0.1A 30V DC 5mA 6V DC, 2mA 12V DC, 1mA 24V DC 2. Characteristics Contact arrangement Standard type Low-level circuit type Expected life (Min. operations) Electrical (at rated load, 20 cpm) (O.T.: Max.) Expected life (Min. operations) Mechanical (at 60 cpm) (O.T.: Specified value) Dielectric strength (initial) Between terminals Between terminals and other exposed parts Between terminals and ground Insulation resistance (Min. at 500V DC) Initial contact resistance Allowable operating speed (No load) Max. operating cycle rate (No load) Ambient temperature Shock resistance (Pin plunger type) Vibration resistance (Pin pluger type) Max. 30 mω (by voltage drop, 1A 6 to 8V DC) O.F N: 10 6 O.F N: Vrms for 1 min. 1,500 Vrms for 1 min. 1,500 Vrms for 1 min. 100 MΩ Max. 100 mω (by voltage drop, 0.1A 6 to 8V DC) 1 to 500 mm/sec. 120 cpm 25 to +85 C 13 to +185 F (Not freezing below 0 C 32 F) Min. 294 m/s 2 (Contact opening: Max. 1 msec.) 10 to 55 Hz at single amplitude of 0.75mm (Contact opening: Max. 1 msec.) 105

107 AH1 3. Operating characteristics 1) Pin plunger 3th digit of Part No. 2) Hinge lever 3) Simulated roller lever DATA Operating force, Max. Release force, Min N 0.29 N N 0.20 N N N 3th digit of Part No. Operating force, Max. Release force, Min N N N N N N 3th digit of Part No. Operating force, Max. Release force, Min N N N N Gold-clad type Range of low-level current voltage Pretravel, Max. Movement differential, Max Pretravel, Max. Movement differential, Max. Overtravel, Min Overtravel, Min Pretravel, Max. Movement differential, Max. Overtravel, Min Operating position 5.5± ±.008 (Distance from mounting hole) 7± ±.012 (Distance from stand off) 5.5± ±.008 (Distance from mounting hole) 7± ±.012 (Distance from stand off) 5.5± ±.008 (Distance from mounting hole) Operating position 6.8± ±.059 (Distance from mounting hole) 8.3± ±.047 (Distance from stand off) 6.8± ±.039 (Distance from mounting hole) 8.3± ±.047 (Distance from stand off) 6.8± ±.039 (Distance from mounting hole) Operating position 11.0± ±.047 (Distance from stand off) 9.5± ±.039 (Distance from mounting hole) 11.0± ±.047 (Distance from stand off) 9.5± ±.039 (Distance from mounting hole) 500 Current (ma) DC voltage (V) 106

108 DIMENSIONS 1. Self-standing PC board terminal (Standard type) Pin plunger 5 ± ± ± ± ± ± ± ± dia dia ± ± ± ± ± ±.006 (P.T.) 0.5 max..020 (O.P.) 5.5 ± ±.008 (O.P.) 7 ± ± C0.3 6-C ± ± ± ±.005 t= ± ± ± ± PC board pattern AH1 Pretravel, Max Movement differential, Max Overtravel, Min Operating position 5.08 ± ± ±0.05 dia..200 ± ± ±.002 dia. Distance from mounting hole, Distance from standoff, 5.5± ±.008 7± ±.012 Hinge lever (P.T.) 2.1 max..083 PC board pattern 5 ± ± ± ± ± dia dia..256 ± ± ± ± ± ± ±.006 (O.P.) 6.8 ± ±.039 (O.P.) 8.3 ± ± C0.3 6-C ± ± ± ±.005 t= ± ± ± ± Pretravel, Max Movement differential, Max Overtravel, Min Operating position 5.08 ± ± ±0.05 dia..200 ± ± ±.002 dia. Distance from mounting hole, Distance from standoff, 6.8± ± ± ±.047 Simulated roller lever 5.4 ± ± ± ±.016 (P.T.) 2.1 max..083 PC board pattern 5 ± ± ± ± R.020 R 6.5 ± dia dia..256 ± ± ± ± ± ± ± to 2.7 R.098 to.106 R (O.P.) 9.5 ± ± C0.3 6-C ± ± ± ± ± ±.005 t= ± ± ± ± Pretravel, Max Movement differential, Max Overtravel, Min Operating position 5.08 ± ± ±0.05 dia..200 ± ± ±.002 dia. Distance from mounting hole, Distance from standoff, 9.5± ± ± ± Solder terminal Pin plunger ± ± ± ± dia dia C C ± ± ± ± ± ±.006 t= Remark: As for other actuator types, dimensions are the same as those of corresponding standard PC board terminal type. 107

109 AH1 3. PC board terminal (Right/Left angle type) Pin plunger C0.3 C.347 Right angle Recommended PC board pattern (top view) ±0.05 dia ±.002 dia. Pin plunger ± ±.012 Left angle (P.T.) 0.5 max ± ±.004 (Button position) ± ± ± ± ± ± ± dia. dia..256 ± ± ± ± ± ± ±.006 (O.P.) 5.5 ± ±.008 Left angle 6 ± ± t= Right angle (3.3) 1.6 (.130).063 Remark: As for other actuator types, dimensions are the same as those of corresponding standard PC board terminal type. NOTES 1. Fixing 1) Use 2mm mounting screws to attach switches with Max N m torque. Use of screw washers or adhesiove lock is recommended. 2) When the operation object is in the free position, force should not be applied directly to the actuator or to the pin plunger. Also force should be applied to the pin plunger from vertical direction to the switch. 3) In setting the movement after operation, the over-travel should be set from 70% to 100%. Setting the movement less than 70% may cause degrading the electrical mechanical performance. 2. When specifying FJ switches, allow ±20% to the listed operating and release forces. 3. Soldering operation 1) For manual soldering: 18 W soldering iron, soldering completed within 3 seconds; do not apply force to the terminals. 2) For automatic soldering tank: 260 C +500 F immersion, completed within 5 seconds, 350 C +662 F immersion, completed within 3 seconds. 4. When switching low-level circuits, FJ low-level circuit type is recommended. 108

110 AV4 ONE OF THE SMALLEST SNAP-ACTION SWITCH IN THE WORLD FU (AV4) SWITCHES FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.2g.007oz) Solder terminal type with mounting holes (0.3g.011oz) TYPICAL APPLICATIONS Compact visual equipment Camera, portable VCR Small-sized audio equipment Cassette tape recorder, Car stereo Office automation equipment Light pen for personal computer, floppy disc apparatus, printer, computer Mechanical life of 300,000 operations minimum Stainless steel plated silver or gold is used for actuating spring Switches can be mounted close together in any directions ORDERING INFORMATION Ex. AV Product Name FU Operating force, max. Terminals Actuators Contacts (by pin plunger) 0: Solder terminal with mounting holes (1.65 mm dia..065 inch dia.) 4: PC board straight terminal 5: PC board angle terminal 6: PC board reverse angle terminal 0: Pin plunger 2: Hinge lever 4: Simulated roller lever 4: 0.98 N Nil: Silver contact 61: Gold contact CONSTRUCTION PC board straight terminal type CONTACT ARRANGEMENT Pin plunger Actuating spring COM NO NC Body Self-standing terminal of 2.54 mm pitch Stand off 109

111 AV4 PRODUCT TYPES Type of contacts Silver contact type Gold contact type SPECIFICATIONS 1. Contact rating Type of contact Silver contact Gold contact Type No. Operating PC board terminal Actuator force, Max. Solder terminal Reverse angle Straight terminal Angle terminal with mounting holes terminal Pin plunger 0.98 N AV4404 AV4504 AV4604 AV4004 Hinge lever 0.25 N AV4424 AV4524 AV4624 AV4024 Simulated roller lever 0.29 N AV4444 AV4544 AV4644 AV4044 Pin plunger 0.98 N AV AV AV AV Hinge lever 0.25 N AV AV AV AV Simulated roller lever 0.29 N AV AV AV AV Resistive load (cosφ]1) 0.5A 30V DC 0.1A 30V DC 2. Characteristics Items Mechanical Life Silver contact Electrical Gold contact Insulation resistance Between non-continuous terminals Voltage Between each terminal and other exposed metal parts withstand Between each terminal and ground Pin plunger type Vibration resistance Lever type Pin plunger type Shock resistance Lever type Contact resistance (initial value) Allowable operation speed Mechanical max. switching frequency Ambient temperature Unit weight DATA Gold contact type Range of low-level current and voltage Characteristics Min operations (at 60 cpm) Min operations (0.5A 30V DC; at 20 cpm) Min operations (0.1A 30V DC; at 20 cpm) Min. 100 MΩ (250V DC by insulation resistance meter) 500V AC for 1 min. 500V AC for 1 min. 500V AC for 1 min. 10 to 55 Hz at single amplitude of 0.75mm (contact opening: max. 1 msec.) 10 to 55 Hz at single amplitude of 0.15mm (contact opening: max. 1 msec.) Min. 294m/s 2 (contact opening: max. 1 msec.) Min. 147m/s 2 (contact opening: max. 1 msec.) Max. 200 mω (by YHP4328A) 0.1mm/s to 500mm/s (pin plunger type) 60 operations/min. 25 to +80 C 13 to +176 F (Not freezing below 0 C 32 F) PC board terminal type: Approx. 0.2g.007oz Solder terminal with mounting holes type: Approx. 0.3g.011oz Current (ma) DC voltage (V) 110

112 AV4 DIMENSIONS General tolerance: ±0.15 ± PC board terminal Straight terminal Pin plunger type 0.75 R R.039 (P.T.) 0.3 max PC board pattern dia dia. (F.P.) 5.2 max..205 (O.P.) 4.80 ± ± Pretravel Movement Differential Overtravel Operating Position Free Position max max min. 4.8± ± max. Hinge lever type (P.T.) 2.4 max (O.P.) ± ±.028 (F.P.) 7.5 max Pretravel Movement Differential Overtravel Operating Position Free Position max max min. 5.8± ± max. Note: All other dimensions are the same as those of pin plunger type. Simulated roller lever type R.024 R (P.T.) 2.2 max..087 (O.P.) 6.1 ± ±.028 (F.P.) 8.0 max Pretravel Movement Differential Overtravel Operating Position Free Position max max min. 6.1± ± max. Note: All other dimensions are the same as those of pin plunger type. 111

113 AV4 2. Angle terminal Right angle terminal Pin plunger type General tolerance: ±0.15 ±.006 Pin plunger Right angle terminal 0.75 R.030 R (P.T.) 0.3 max dia (F.P.) 5.2 max (O.P.) 4.80 ± ± Pretravel Movement Differential Overtravel Operating Position Free Position max max min. 4.8± ± max. Note: All other dimensions of hinge lever type and simulated roller lever type are the same as those of straight terminal types. Left angle terminal Pin plunger type Pin plunger Left angle terminal 0.75 R.030 R (P.T.) 0.3 max dia (F.P.) 5.2 max (O.P.) 4.80 ± ± Pretravel Movement Differential Overtravel Operating Position Free Position max max min. 4.8± ± max. Note: All other dimensions of hinge lever type and simulated roller lever type are the same as those of straight terminal types. 3. Solder terminal with mounting holes Pin plunger type (P.T.) 0.3 max (O.P.) ± ± dia..065 (F.P.) 5.8 max..228 Pretravel Movement Differential Overtravel Operating Position Free Position max max min. 5.4± ± max

114 AV4 Hinge lever type General tolerance: ±0.15 ± (P.T.) 2.4 max..094 (O.P.) 6.4 ± ±.024 (F.P.) 9.0 max dia Pretravel Movement Differential Overtravel Operating Position Free Position max max min. 6.4± ± max. Note: All other dimensions are the same as those of pin plunger type. Simulated roller lever type R.024 R (P.T.) 2.2 max (O.P.) 6.7 ± ± dia..065 (F.P.) 9.4 max..370 Pretravel Movement Differential Overtravel Operating Position Free Position max max min. 6.7± ± max. Note: All other dimensions are the same as those of pin plunger type. NOTES 1. Mounting 1) After mounting and wiring, the insulation distance between ground and each terminal should be confirmed as sufficient. 2) When the operation object is in the free position, force should not be applied to the actuator or to the pin plunger. Also force should be applied to the pin plunger from vertical direction to the switch. 3) In setting the movement after operation, the over-travel should be set within the range of the specified O.T. value. 4) In fastening the switch body, use the M1.4 screw, with tightening torque of not more than N m. 2. Soldering 1) Hand soldering should be accomplished in less than 5 seconds with an iron below 18 watts. Keep the soldering tip temperature less than 320 C 608 F. Avoid applying force to the terminals. 2) In the case of automatically soldering bath, soldering should be done less than 5 seconds in 260 C 500 F solder bath. 3) Terminal portion must not be moved within 1 minute after soldering. Also no tensile strength of lead wires should be applied to the terminals. 4) When using the angle terminal type, insert an insulation separator between the switch body and the printed circuit board (Insulation separator 0.2 to 0.4mm.008 to.016 inch thick) to prevent the soldering flux from flowing under the PC board. 3. Cleaning As FU switch is not completely sealed construction, avoid cleaning. 4. Selection of switch When specifying FU switches, allow ±20% to the listed operating characteristics. 5. Avoid using and keeping switches in the following conditions: In corrosive gases In a dusty environment Where silicon atmosphere prevails 6. When switching low-level circuits (max. 100 ma), gold contact types are recommended. 7. When using the lever type, avoid applying force from the reverse and side direction of actuating. 113

115 AGX VDE SAFETY INTERLOCK SWITCH SMALL SIZE & LIGHT FORCE GX (AGX) SWITCHES 1a FEATURES Constructed with dual restoration springs and double cut-off for safety Contact gap of greater than 4mm.157inch (Conforming to IEC 950) As for 3 Form A type, combination of power contact and signal contact is available UL/CSA/SEMKO/TÜV/VDE approved 3a 2a ORDERING INFORMATION TYPICAL APPLICATIONS Door interlock of copiers, printers, facsimiles Door interlock of other compact appliances Ex. AGX Product Name GX PRODUCT TYPES 114 Rating Standard type 10.1A 250V AC High capacity type 16A 250V AC Contact arrangement Capacity and mounting method Terminals 1: 1 Form A Power switching contact 2: 2 Form A Power switching contact 3: 3 Form A Power switching contact 6: 1 Form A Power switching contact and 2 Form A Signal switching contact 7: 2 Form A Power switching contact and 1 Form A Signal switching contact 0: Standard type 10.1 A (Snap-in mounting) 0: High capacity type 16 A (EOL)* (Snap-in mounting) *Product is end of life 5:.250 Quick-connect terminal (O.T. 2 mm) 6:.250 Quick-connect terminal (O.T. 4 mm) Overtravel (O.T.) Min Contact arrangement Switching timing 1st ON 2nd ON Part number 1 Form A Power switching contact AGX105 2 Form A Power switching contact AGX205 1 Form A Power switching contact AGX106 2 Form A Power switching contact AGX206 3 Form A Power switching contact 3a power AGX306 1 Form A Power switching contact 1a power 2a signal AGX606 2 Form A 3 Form A Signal switching contact 2 Form A Power switching contact 1 Form A 2a power 1a signal AGX706 Signal switching contact 1 Form A Power switching contact AGX125 2 Form A Power switching contact AGX225 1 Form A Power switching contact AGX126 2 Form A Power switching contact AGX226 3 Form A Power switching contact 3a power AGX326 1 Form A Power switching contact 1a power 2a signal AGX626 2 Form A 3 Form A Signal switching contact 2 Form A Power switching contact 1 Form A 2a power 1a signal AGX726 Signal switching contact

116 SPECIFICATIONS 1. Contact rating Number of contact Standard type power switching contact High capacity type power switching contact Signal switching contact (3 Form A only) Resistive load (cos φ ] 1) 10.1A 125V AC 10.1A 250V AC 6A 30V DC 3A 48V DC (3 Form A type only) 16A 125V AC 16A 250V AC 6A 30V DC 3A 48V DC (3 Form A type only) 0.1A 48V DC Contact Low-level circuit: 1mA 5V DC Remark: Motor load designates an inrush current switching capability of 6 times the indicating rating Motor load* (EN ) (cos φ ] 0.6) 3A 125V AC 3A 250V AC 4A 125V AC 4A 250V AC AGX 2. Characteristics Type Standard type High capacity type Expected life Mechanical (at 60 cpm) Electrical (at 20 cpm, operating speed: 10mm/sec.) Insulation resistance Between terminals Dielectric strength Between terminals and other exposed metal parts Between terminals and ground *Remark: Test condition and judgement are complying with "JIS C4505", "EN61058" and "UL1054" min (at 10.1A 250V AC) 100MΩ at 500V DC 2,000Vrms for 1 minute 2,500Vrms for 1 minute 10 5 (at 16A 250V AC) 2,000Vrms for 1 minute Initial contact resistance 100mΩ Max. (by voltage drop at 1A, 6 to 8V DC) Temperature rise (terminal portion) Initial 45 deg. Max., After test 55 deg. Max. Vibration resistance 10 to 55Hz at single amplitude of 0.75mm Shock resistance Min. 294m/s 2 Actuator strength 49N for 1 minute (For operating direction) Tensile terminal strength Min. 147N (Pulling for operating direction) Allowable operating speed Min. 10 to 300mm/second Allowable operating cycle rate 60 cpm Temperature resistance 40 C to 45 C 40 F to 49 F: 48 hours, +80 C to +90 C +176 F to +194 F: 48 hours Ambient temperature 25 C to +85 C 13 F to +185 F (Not freezing nor condensing) Flame retardancy Min. UL 94V-1 Tracking resistance (CTI) Min Operating characteristics Contact arrangement Standard type 10.1A 250V AC High capacity type 16A 250V AC Part number Operating force (O.F.) Max. Total operating force (T.F) Max. Push button position: 2.4mm.094inch Free position (F.P.) Max. Operating position (O.P.) Total travel position (T.T.P.) Over travel (O.T.) Min. 1 Form A AGX N 4.90 N ± ± Form A AGX N 4.90 N ± ± Form A AGX N 6.86 N ± ± Form A AGX N 6.86 N ± ± Form A AGX N 5.88 N ± ± Form A AGX N 6.86 N ± ± Form A AGX N 7.85 N ± ± Form A AGX N 8.82 N ± ± Form A AGX N 9.81 N ± ± Form A AGX N 7.85 N ± ± Remark: With the 3 Form A type sequence operation type, the specifications for the contact where the operation position turns ON first are as per the above table. However, the specifications for the contact where the operation position turns ON later are delayed by approximatery 0.8 mm.031 inch compared with the above table. 115

117 AGX CONSTRUCTION Dual safety construction Dual restoration spring Double cut-off type 2mm min..079inch min. 4mm.157inch or more contact gap (2mm.079inch or more on one side) Quick-connect terminal DIMENSIONS General tolerance: ±0.4 ± Form A Hole cutting dimension R0.3 max. R.012 max. 2 Form A (F.P.) (O.P.) Quick-connect terminal dia..197 dia Panel thickness A 1.0 to to to to.098 Dimension A (Cooper is standard as panel material) Remark: 1 Form A type does not have terminal No.1 nor No.2 3 Form A Hole cutting dimension R0.3 max. R.012 max A Power switching contact (F.P.) (O.P.) dia..315 dia Panel thickness Dimension A 0.8 to to (Cooper is standard as panel material) Signal switching contact 1.75 to to Signal switching contact.250 Quick-connect terminal Remark: Power switching contact type has.250 Quick-connect terminal and signal switching contact type has.110 Quick-connect terminal. 116

118 NOTES 1. Switch mounting Mount the switch with the hole cutting dimensions shown in the drawing. 2. Adjustment of the operating device: With respect to the position of the operating device and the switch body, set the position as indicated in the condition on the right. If this condition is exceeded, the mechanical and electrical performance will be impaired. In addition, the force applied by the oprating device should be in a perpendicular direction. Even if the pushbutton is used in the full total travel position, there will be no influence on the life of the switch. Free condition Operating device O.T. 2mm type: 8mm.315inch min. O.T. 4mm type: 10mm.394inch min. Operating condition 1 Form A, 2 Form A: 2.4 to 3mm.094 to.118inch 3 Form A: 2.4 to 4mm.094 to.157inch 3. Confirming insulating distance Before mounting and wiring, the insulating distance between terminals and between the terminals and ground should be checked for assurance of proper distance. With respect to the terminal connections, it is recommended that receptacles with insulating sleeves or "Positive Lock Connector*" be used. Also consideration should be given to the wiring not to apply force to the terminal section normally. *Registered by AMP, Ltd. 4. Regarding fastening lead wires to terminals Use.250 receptacle (terminal thickness 0.8mm.031inch) or.110 receptacle (terminal thickness 0.5mm.020inch) should be used for connection. Make sure the sockets are straight. If they are skewed, the terminals will require excessive insertion force. The insertion force varies according to manufacturer s AGX specifications. Check it for the sockets you are using. 5. Material of the panel Steel sheet is recommended as the panel material. When using soft material, confirm the condition for actual use. 6. Quality check under actual loading conditions To improve reliability, check the switch under actual loading conditions. Avoid any situation that may adversely affect switching performance. 7. Avoid using and keeping switches in the following conditions. In corrosive gases In a dusty environment Where silicon atomosphere prevails REFERENCE 1. Outline of UL1054 test Overload test Standard type: 12.5A 250V AC (Power factor 0.75 to 0.8) High capacity type: 20A 250V AC (Power factor 0.75 to 0.8) Endurance test Standard type: 10A 250V AC (Power factor 0.75 to 0.8) High capacity type: 16A 250V AC (Power factor 0.75 to 0.8) After testing, temperature rise of terminals should be less than 30 C 86 F and no abnormality should be observed in characteristics. 2. Outline of EN test After switching 25,000 times on the +5 above load condition at both 85 0 C F and 25±10 C 77±50 F, temperature rise of terminals should be less than 55 C 131 F and no abnormality should be observed in characteristics. 24A 50 to 100ms 2 sec. 4 sec. J7: 10A AC: 250V (Power factor 0.6) INTRODUCTION OF CONNECTORS (made by Nippon Tanshi co.,ltd) 1. For 2 Form A power switching contact type 2. For 2 Form A power switching contact type of 2 Form A power switching contact + 1 Form A signal switching contact For 2 Form A power switching contact type For 2 Form A power switching contact type of 2 Form A power switching contact type Applicable GX switch part No.: AGX205, AGX206, AGX225, AGX226 * Housing Model number: N * Receptacle Model numbers (for narrow wires, post-plated product) M2 (for narrow wires, wood veneer plated product) M2 (for thick wires) Applicable GX switch part No.: AGX706, AGX726 * Housing Model number: N * Receptacle Model numbers M2, M2, M3 (wire size differences) Remark: Please consult us if you need above connectors. 117

119 AV1 VDE SAFETY INTERLOCK SWITCH CONSTRUCTED WITH DUAL RESTORATION SPRINGS FEATURES 8mm.315inch or more is assured as insulation distance between contacts (Snap-in mounting 2 Form A and 3 Form A type) Durability of 100,000 times (16A 380V AC) is assured for UL interlock circuit Constructed with easy-to-connect terminals Terminal specifications is.250 Quick- Connect (based on DIN standards) Connection can be made with insulating sleeve on connecting lug UL/CSA/VDE/SEMKO approved GW (AV1) SWITCHES TYPICAL APPLICATIONS 1. Office equipment Copies Facsimiles Projectors 2. Home appliances Microwave ovens Refrigerators ORDERING INFORMATION Ex. AV Type of switch AV1: GW switch Contact arrangement 1: 3 Form A (contact gap: 8 mm.315 inch) 2: 2 Form A (contact gap: 8 mm.315 inch) 3: 2 Form A (contact gap: 6 mm.236 inch) 4: 1 Form A 1 Form B 5: 1 Form B 6: 1 Form A Mounting method 0: Screw mounting 1: Snap-in mounting type 2: Snap-in mounting type with button guard Remarks: 1. When ordering UL/CSA (16 A 380 V AC, 1/2HP 125/250 V AC, operating cycle: ) VDEÆSEMKOÆT V approved types, add suffix 9 to the type No., for example AV When ordering UL/CSA (16 A 380 V AC, operating cycle: ) VDE and SEMKO approved types, add suffix 3 to the type No., for example AV This product is end of life (EOL) and will be replaced by a 10.1 A type, scheduled April 2005 PRODUCT TYPES Type Part number Mounting method Button guard Contact arrangement Contact gap 1 Form A Min AV Form B Min AV1505 Screw mounting Without 1 Form A 1 Form B Max AV Form A Min AV Form A Min AV1215 Without 3 Form A Min AV1115 Snap-in mounting 2 Form A Min AV1225 With 3 Form A Min AV

Turquoise Stroke Switches

Turquoise Stroke Switches Long Stroke and Sliding Contact Construction Sealed Switches Turquoise Stroke Switches 13.3 10.1 (Unit: mm) RoHS compliant FEATURES For pin plunger, it maintains a long stroke OT (Over Travel) with over

More information

Turquoise Stroke Mini Switches

Turquoise Stroke Mini Switches Long Stroke, Sliding Contact Construction Sealed Switches Turquoise Stroke Mini Switches 5.3 (Unit: mm) 7.85 5.3 Terminal 13.55 Wire leads RoHS compliant FEATURES Miniaturization achieved with changing

More information

TURQUOISE STROKE SWITCHES

TURQUOISE STROKE SWITCHES ULTRA-LONG STROKE, HIGH CONTACT RELIABILITY SEALED SWITCHES (SAME SIZE AS J TYPE) ASQ1 TURQUOISE STROKE SWITCHES 9.6 13.3 FEATURES (mm) http://panasonic-denko.co.jp/ ac/e/service/environment 1. Same size

More information

High Operating Precision Basic Switches with High Capacity and Long Life

High Operating Precision Basic Switches with High Capacity and Long Life High Operating Precision Basic Switches with High Capacity and Long Life AM1 (NZ) SWITCHES 24.1 49.2 17.5 FEATURES 10 A Current switching capacity High precision and long life Versatile variety of actuators

More information

Selector Chart Technical Terminology & Cautions For Use Turquoise Switches Turquoise Stroke Switches Turquoise Switch Basic Switch Miniature Switch

Selector Chart Technical Terminology & Cautions For Use Turquoise Switches Turquoise Stroke Switches Turquoise Switch Basic Switch Miniature Switch T A B L E O F C O N T E N T S Page Selector Chart...4 Technical Terminology & Cautions For Use...8 Turquoise Switches...12 Notes For Turquoise Switches...13 Turquoise Stroke Switches...15 Turquoise Switch

More information

Ultra-miniature Size Switches with High Precision AH 1. Actuator. 0: Pin plunger 2: Hinge lever 4: Simulated roller lever N 0.25N 0.

Ultra-miniature Size Switches with High Precision AH 1. Actuator. 0: Pin plunger 2: Hinge lever 4: Simulated roller lever N 0.25N 0. Ultra-miniature Size Switches with High Precision AH1 (FJ) Switches Left angle terminal RoHS compliant Right angle terminal FEATURES Compact size, light weight and high precision Switches that can be used

More information

Sliding contact construction Switches for Low-level Loads

Sliding contact construction Switches for Low-level Loads Sliding contact construction Switches for Low-level Loads AEQ (EQ) Switches 13.3 10.1 (Unit: mm) RoHS compliant FEATURES Handles low level load: 100 μa at 3 VDC to 100 ma 30 VDC Long stroke: For pin plunger

More information

ABJ (BJ) Turquoise Switches

ABJ (BJ) Turquoise Switches Ultra-miniature Size Sealed Switches ABJ (BJ) Turquoise Switches Terminal type Mounting hole 2.3 mm type FEATURES Ultra-miniature size, High sealing performance sealed switches Elastomer double molding

More information

ABV (BV) Turquoise Switches

ABV (BV) Turquoise Switches Miniature Size Sealed Switches ABV (BV) Turquoise Switches 15.9 Terminal type 33.0 10.3 FEATURES Integral construction of body and cover, sealed switches Long life (Mechanical life: Min. 5 10 6 ) Wide

More information

TURQUOISE STROKE SWITCHES

TURQUOISE STROKE SWITCHES Long Stroke and Sliding Contact Construction Sealed Switches TURQUOISE STROKE SWITCHES 13.3 10.1 (Unit: ) RoHS compliant FEATURES For pin plunger type, it maintains a long stroke OT (Over Travel) with

More information

ABS (BS) Turquoise Switches

ABS (BS) Turquoise Switches Subminiature Size Sealed Switches ABS (BS) Turquoise Switches 11.1 Terminal type 19.8 6.4 Wire leads FEATURES Subminiature size, High sealing performance sealed switches Elastomer double molding technology

More information

Small, Highly reliable Tilt Detection Switches Containing a Photo Sensor

Small, Highly reliable Tilt Detection Switches Containing a Photo Sensor Small, Highly reliable Tilt Detection Switches Containing a Photo Sensor AHF2 (TiP) Switches RoHS compliant FEATURES Non-contact type switch containing a photo sensor The contact form is equivalent to

More information

TURQUOISE SWITCHES J TYPE (ABJ)

TURQUOISE SWITCHES J TYPE (ABJ) HIGH ENVIRONMENTAL RESISTANCE TURQUOISE SWITCHES J TYPE (ABJ) Dust protected type Immersion protected type (wire leads bottom type) (Mounting hole 2.3mm.091inch type) (Mounting hole 2.3mm.091inch type)

More information

TURQUOISE SWITCHES J TYPE (ABJ)

TURQUOISE SWITCHES J TYPE (ABJ) HIGH ENVIRONMENTAL RESISTANCE ABJ1,2,3,4,5 TURQUOISE SWITCHES J TYPE (ABJ) Dust protected type Immersion protected type (wire leads bottom type) (Mounting hole 2.3mm.091inch type) (Mounting hole 2.3mm.091inch

More information

Operation Switches Selector Chart

Operation Switches Selector Chart Operation elector Chart election item Load edium-to high-capacity loads ymbol aximum rated capacity indicated in the table below. ounting method Protect construction ounting panel with round holes ealed

More information

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal ) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water spray or excessive

More information

Electromechanical Line Card Catalog

Electromechanical Line Card Catalog Electromechanical Line Card Catalog 800-344-2112 na.industrial.panasonic.com industrial@us.panasonic.com ELECTROMECHANICAL na.industrial.panasonic.com/products/electromechanical Light Touch Switches Detector

More information

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- - Sealed Miniature Basic Switch D2VW Sealed Miniature Basic Switch Conforms to IP67 (Molded Lead Wire Type Only) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to

More information

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend General-purpose Basic Switch X Direct Current Switch with Built-in Magnetic Blowout Incorporates a small permanent magnet in the contact mechanism to deflect the arc to effectively extinguish it. Ideal

More information

TURQUOISE SWITCHES ABJ TYPE

TURQUOISE SWITCHES ABJ TYPE HIGH ENVIRONMENTAL RESISTANCE ABJ1,2,3,4,5 TURQUOISE SWITCHES ABJ TYPE.5 12.8 Dust protected type Iersion protected type (wire leads bottom type) (Mounting hole 2.3 type) (Mounting hole 2.3 type) FEATURES

More information

DL (AZD1) Mini Limit Switches

DL (AZD1) Mini Limit Switches COMPACT SIZE LIMIT SWITCES DL (1) Mini Limit Switches (with forced contact opening mechanism) An economic compact limit switch equipped with a forced contact opening mechanism and excellent environment

More information

SAFETY INTERLOCK SWITCH CONSTRUCTED WITH DUAL RESTORATION SPRINGS FEATURES

SAFETY INTERLOCK SWITCH CONSTRUCTED WITH DUAL RESTORATION SPRINGS FEATURES SAFETY INTERLOCK SWITCH CONSTRUCTED WITH DUAL RESTORATION SPRINGS FEATURES mm inch or more is assured as insulation distance between contacts (Snap-in mounting and 3 Form A type) Durability of 100,000

More information

TURQUOISE SWITCHES V TYPE (ABV)

TURQUOISE SWITCHES V TYPE (ABV) HIGH ENVIRONMENTAL RESISTANCE ABV1 TURQUOISE SWITCHES V TYPE (ABV) FEATURES Miniature size (33 15.9.3 mm) (99.626.406 inch) Sealed construction for use in adverse environment Sealed construction by epoxy

More information

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P Sealed Subminiature Basic Switch Sealed Basic Switch with Simplified Construction, Mounting Compatible with SS and D2SW Series. Sealing by using rubber packing means the switch can be used in dust-proof

More information

HL (AZH) Limit Switches

HL (AZH) Limit Switches COMPACT SIZE LIMIT SWITCHES HL (AZH) Limit Switches Compact, high-performance limit switch with superior environmental resistance. Broad lineup covers from die casting cases to economical plastic cases.

More information

D2SW. Sealed Subminiature Basic Switch. Ordering Information Model Number Legend D2SW-

D2SW. Sealed Subminiature Basic Switch. Ordering Information Model Number Legend D2SW- Sealed Subminiature Basic Switch Sealed Subminiature Basic Switch Conforming to IP67 (Molded Lead Wire Type Only) Use of epoxy resin assures stable sealing, making this switch ideal for places subject

More information

AM1 (NZ BASIC) SWITCHES

AM1 (NZ BASIC) SWITCHES HIGH CONTACT CAPACITY, PRECISE OPERATION AM1 (NZ BASIC) SWITCHES 24.1 FEATURES 15 A High current switching capacity and high precision Wide allowance of operating speed Versatile variety of actuators UL/CSA

More information

Low-torque Basic Switch

Low-torque Basic Switch Low-torque Basic Switch Highly Reliable Rotary-action Switch for Low Torque Operation (0.5 m N m {5.1 gf cm}) 0.5-A rated model employs crossbar gold-alloy contacts for excellent contact reliability in

More information

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31 Snap Action Switch Subminiature Snap Action Switch Switches 3 A loads (general-purpose), 1 A loads (low force general-purpose) and 0.1 A loads(microvoltage/ microcurrent) Long life span assured by high-precision

More information

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information Sealed Ultra Subminiature Basic Switch Smallest sealed snap-action switch in the industry with a very long stroke for reliable ON/OFF action. The case dimensions are 78% of conventional, contributing to

More information

High sensitivity. Low current load type. type. Short plunger ~ Fine plunger ~ ~ Lever ~ Roller lever ~ Short roller lever ~

High sensitivity. Low current load type. type. Short plunger ~ Fine plunger ~ ~ Lever ~ Roller lever ~ Short roller lever ~ 6 BZ, BA, BE Series Specifications Standard Basic Switches FEATURES These Switches are Used Extensively and Have Earned the High Respect of Our Customers. Standard basic switches (BZ, BA, BE Series) are

More information

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information Sealed Ultra Subminiature Basic Switch Smallest sealed snap-action switch in the industry with a very long stroke for reliable ON/OFF action. The case dimensions are 78% of conventional models, contributing

More information

HL (AZH) LIMIT SWITCHES

HL (AZH) LIMIT SWITCHES COMPACT SIZE LIMIT SWITCHES LIMIT SWITCHES U L PRODUCT TYPE 1. Limit Switches Actuator Type Push plunger Roller plunger Cross roller plunger Panel mount push plunger Panel mount roller plunger Panel mount

More information

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL.

TL RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, etc. ORDERING INFORMATION TYPES. High Load Relay for Smart Junction Box ACTL. High Load Relay for Smart Junction Box TL RELAYS High heat-resistant type: Sealed Pin in Paste compliant type: Flux tight New 14.4.7 11.433 1.3 FEATURES Large capacity switching

More information

SL (AZ3) Micro Limit Switches

SL (AZ3) Micro Limit Switches SUBMINIATURE SIZE LIMIT SWITCHES SL (AZ3) Micro Limit Switches Quickly upgraded to limit switches with lamps by mounting an LED lamp socket. Rubber cover type (roller ) Compliance with RoHS Directive FEATURES

More information

Technical Guide for Basic Switches

Technical Guide for Basic Switches Terms for Basic Switches Technical Guide for Basic Switches General Terms (1) General Terms Basic Switch: A small-size switch with a very small contact gap and snap-action mechanism and with a contact

More information

VERTICAL TYPE LIMIT SWITCHES (INCLUDES LAMP TYPE)

VERTICAL TYPE LIMIT SWITCHES (INCLUDES LAMP TYPE) VERTICAL TYPE LIMIT SWITCHES (INCLUDES LAMP TYPE) Limit Switches General use vertical limit switch. Type with a lamp which makes maintenance convenient; either a neon AC powered lamp or an LED DC powered

More information

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water spray or excessive

More information

TV-5, TV-8 rated 10mm flat power relays Silent type is available

TV-5, TV-8 rated 10mm flat power relays Silent type is available TV-, TV- rated 1mm flat power relays Silent type is available LK-F RELAYS TV standards compatible: TV- and TV- TV- type: 7 A inrush current and switching possible at A rated current. : 11 A inrush current

More information

Pressure sensor with built-in amplification and temperature compensation circuit

Pressure sensor with built-in amplification and temperature compensation circuit sensor with built-in amplification and temperature compensation circuit PS-A PRESSURE SENSOR (built-in amplification and temperature compensating circuit) NEW FEATURES 1. Contains built-in amplification

More information

Subminiature Basic Switch

Subminiature Basic Switch Subminiature Basic Switch Subminiature Basic Switch Offers Long Life and High Reliability A design that combines simplicity and stability by the use of two split springs ensures a long durability of 30,000,000

More information

Technical Explanation for Basic Switches

Technical Explanation for Basic Switches CSM_MicroSwitch_TG_E_3_2 Introduction What Is a Basic Switch? A Basic Switch is a small switch with a very small contact gap and snap-action mechanism and with a contact structure that switches for a specified

More information

Subminiature Basic Switch

Subminiature Basic Switch Subminiature Basic Switch SS Subminiature Basic Switch Offers Long Life of 30,000,000 Operations A design that combines simplicity and stability by the use of two split springs ensures a long service life

More information

Safety Limit Switch

Safety Limit Switch Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_5_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit

More information

HL (AZH) Limit Switches

HL (AZH) Limit Switches COMPACT SIZE LIMIT SWITCHES HL (AZH) Limit Switches Wide selections of actuators, terminals and bodies to meet any application Excellent environmental resistance Die casting caseiec IP67 Plastic caseiec

More information

Technical Information Solid State Relays. Glossary. Solid State Relays

Technical Information Solid State Relays. Glossary. Solid State Relays Glossary Terms Meaning Circuit functions Photocoupler Transfers the input signal and insulates inputs and outputs as well. Photoctriac coupler Zero cross circuit Trigger circuit Snubber circuit A circuit

More information

List of Models Short post on Long post on left left. Without posts Actuator Terminals Contact form

List of Models Short post on Long post on left left. Without posts Actuator Terminals Contact form Smallest sealed snap-action switch in the industry with a very long stroke for reliable ON/OFF action The case dimensions are 78% of conventional models, contributing to down-sizing of mechanical modules.

More information

AM5 (QV) SWITCHES AM5

AM5 (QV) SWITCHES AM5 MINIATURE SWITHES WITH HIGH PREISION (QV) SWITHES 5.9 FEATURES High precision as a result of designing ideal spring by using computer analysis O.P. 4.7±0.4mm Reliable design with shock resistance min.

More information

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening SPATTER-GUARDED SWITCHES Model LS Effective countermeasures against the adhesion of spatter. UL/CSA/GB(CCC marking)-approved. (excluding some models) ORDER GUIDE Actuator Name Roller lever type Shape Max.

More information

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend ealed ubminiature Basic witch ealed ubminiature Basic witch Conforming to IP67 (Excluding the terminals on terminal ) Use of epoxy resin assures stable sealing, making this switch ideal for places subject

More information

MIDDLE LOAD RELAY FOR SMART J/B

MIDDLE LOAD RELAY FOR SMART J/B MIDDLE LOAD RELAY FOR SMART J/B CN-M RELAYS (ACNM) New Compliance with RoHS Directive FEATURES. Best space savings in its class.. Compact and high-capacity A load switching.. Full line up (High heat-resistant

More information

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend ealed ubminiature Basic witch ealed ubminiature Basic witch Conforming to IP67 (Excluding the terminals on terminal ) Use of epoxy resin assures stable sealing, making this switch ideal for places subject

More information

VL (AZ8) Limit Switches

VL (AZ8) Limit Switches COMPACT SIZE LIMIT SWITCHES Limit Switches A compact and accurate vertical limit switch. Type with a lamp which makes maintenance convenient; either a neon AC powered lamp or an LED DC powered lamp. With

More information

VL (AZ8) Mini Limit Switches

VL (AZ8) Mini Limit Switches COMPACT SIZE LIMIT SWITCHES VL (AZ8) Mini Limit Switches A compact and accurate vertical limit switch. Type with a lamp which makes maintenance convenient; either a neon AC powered lamp or an LED DC powered

More information

D2AW. Long stroke seal switch with high reliability and high insulation performance. Model Number Legend. Sealed Ultra Subminiature Basic Switch

D2AW. Long stroke seal switch with high reliability and high insulation performance. Model Number Legend. Sealed Ultra Subminiature Basic Switch Long stroke seal switch with high reliability and high insulation performance Double reliability by twin contacts (=Clipping contact). Foreign materials are cleaned out by the sliding

More information

VL (AZ8) Limit Switches

VL (AZ8) Limit Switches COMPACT SIZE LIMIT SWITCHES VL (AZ8) Limit Switches A compact and accurate vertical limit switch. Switches with indicator lamp available for convenient maintenance; either a neon AC powered lamp or an

More information

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models Enclosed Switch Economical, High Utility Enclosed Switch High precision and long life (10,000,000 mechanical operations) through employment of the moving spring used in OMRON Z Basic Switch. Sealed with

More information

BZSeries. Basic Switches

BZSeries. Basic Switches Basic Switches BZSeries These switches have been used extensively and have earned the high respect of our cusmers. Standard basic switches BZ Series are representative of Yamatake basic switches for their

More information

Direct Current Switch with Built-in Magnetic Blowout

Direct Current Switch with Built-in Magnetic Blowout General-purpose Basic Switch X Direct Current Switch with Built-in Magnetic Blowout Incorporates a small permanent magnet in the contact mechanism to deflect the arc to effectively extinguish it. Same

More information

1293 Limit Switches Selection Guide

1293 Limit Switches Selection Guide 1293 Limit Classification Subminiature size (Horizontal) size (Horizontal) Product name (AZ3) Micro Limit (AZH) Limit (Die cast case) (AZH) Limit (Die cast case) (AZH) Limit (Plastic case) Appearance USE

More information

Model Number Structure

Model Number Structure Small Sealed Switch D4E-@N Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E Flat springs with an improved lever ratio of the built-in switch ensure smooth snap action

More information

BZSeries. Basic Switches

BZSeries. Basic Switches Basic Switches BZSeries These switches have been used extensively and have earned the high respect of our cusmers. Standard basic switches BZ Series are representative of Yamatake basic switches for their

More information

TC RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, Defogger, Seat heater, etc. ORDERING INFORMATION. High Load Relay for Smart J/B ACTC

TC RELAYS. TYPICAL APPLICATIONS Head lamp, Fog lamp, Fan motor, Defogger, Seat heater, etc. ORDERING INFORMATION. High Load Relay for Smart J/B ACTC High Load Relay for Smart J/B TC RELAYS /High heat-resistant type: Sealed Pin in Paste compliant type: Flux tight FEATURES Large capacity switching despite small size. Can replace

More information

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY

COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY COMPACT BUT CUT OFF DC POWER CURRENT, POWER CAPSULE CONTACT RELAY EB RELAYS (AEB) (1A type) FEATURES Compact and high capacity using double contacts in series and permanent magnet installed. (1,A/3 times)

More information

Pressure Sensor/PS-A (ADP5)

Pressure Sensor/PS-A (ADP5) Sensor PS-A sensor Built-in amplifi er and compensating circuit Features Built-in amplifier and temperature compensation circuit, no need for circuit design and characteristic adjustment High accuracy

More information

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark Limit Switch Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark Features positive opening mechanism (NC contacts only) that opens contacts, thus preventing faulty

More information

COMPACT FLAT SIZE FOR AUTOMOTIVE

COMPACT FLAT SIZE FOR AUTOMOTIVE PACT FLAT SIZE FOR AUTOMOTIVE RELAYS RoHS compliant FEATURES Compact flat type Flat size enables it to be built-in switch units. PC board terminal type: 9.5 mm.374 inch Surface-mount terminal

More information

Limit Switches General Catalogue /2005

Limit Switches General Catalogue /2005 Limit Switches General Catalogue 2005 TABLE OF CONTENTS Page Limit Switches Selector Chart...4 Actuator selection...6 TECHNICAL INFORMATION...7 PROTECTIVE CONSTRUCTION...9 CAUTIONS FOR USE...10 IMPROVEMENT

More information

Cautions in Using The Relays 1/5

Cautions in Using The Relays 1/5 Cautions in Using The Relays 1/5 Cautions for using the relay are mentioned hereafter and please read them before use. Also, in order to increase the reliability when you use the relay, confirm the actual

More information

OMRON Z LIMIT SWITCH

OMRON Z LIMIT SWITCH Issued April 00 DATA SHEET OMRON LIMIT SWITCH Based on OMRON Datasheet General-purpose Basic Switch CSM DS_E Best-selling Basic Switch Boasting High Precision and Wide Variety A large switching capacity

More information

Basic Switches. BZ Series APPLICATIONS SELECTION GUIDE. High-quality switches with UL certification. *C-UL approval number: E96090.

Basic Switches. BZ Series APPLICATIONS SELECTION GUIDE. High-quality switches with UL certification. *C-UL approval number: E96090. Basic Switches BZ Series These switches have been used extensively and have earned the high respect of our cusmers. Standard basic switches BZ Series are representative of Azbil basic switches for their

More information

QL (AZ4) Limit Switches

QL (AZ4) Limit Switches SUMINITURE SIZE LIMIT SWITCHES QL (Z4) Limit Switches High precision micro limit switches with excellent environmental protection. Quickly upgraded to limit switches with lamps by mounting an LED lamp

More information

Compact plastic limit switches with positive opening mechanism

Compact plastic limit switches with positive opening mechanism Compact limit switches with positive opening mechanism LJK-N Series Positive opening mechanism Positive opening mechanism meets standards worldwide. A wide variety of actuators is available. The LJK-N

More information

POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation

POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation (SF3 pending) (SF3 pending) (SF3 pending) POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation SF-RELAYS π.098±.0.098±.0.098±.0 5.0.984 6.5±0.3.650±.0 33±0.3.99±.0 6.5±0.3.650±.0

More information

Limit Switches Technical Information

Limit Switches Technical Information Limit Switches Technical Information Safety Precautions For the individual precautions for each Switch, refer to the Precautions section of each Switch.!WARNING Do not touch the charged switch terminals

More information

Ordering Information. Text Surface-Mounting Signal Relay G6K

Ordering Information. Text Surface-Mounting Signal Relay G6K Surface-Mounting Relay with the World s Smallest Mounting Area and a Height of Only 5.2 mm ROHS compliant. Sub-miniature model as small as 5.2 (H) x 6.5 (W) x 10 (L) mm is ideal for high-density mounting.

More information

COMPACT FLAT SIZE FOR AUTOMOTIVE

COMPACT FLAT SIZE FOR AUTOMOTIVE PACT FLAT SIZE FOR AUTOMOTIVE RELAYS RoHS compliant FEATURES Compact flat type Flat size enables it to be built-in switch units. PC board terminal type: 9.5 mm.374 inch Surface-mount terminal

More information

Best-selling Basic Switch Boasting High Precision and Wide Variety

Best-selling Basic Switch Boasting High Precision and Wide Variety General-purpose Basic Switch Z Best-selling Basic Switch Boasting High Precision and Wide Variety A large switching capacity of A with high repeat accuracy. A wide range of variations in contact form for

More information

Compact plastic limit switches with positive opening mechanism

Compact plastic limit switches with positive opening mechanism Compact limit switches with positive opening mechanism LJK-NSeries Positive opening mechanism Positive opening mechanism meets standards worldwide. A wide variety of actuators is available. The LJK-N conforms

More information

Small Limit Switch D4V

Small Limit Switch D4V Small Limit Switch DV Compact Vertical Models Sized for Asian Standards Compact new design approximately / the size of OMRON vertical Limit Switches. Structure enables the terminal section to be fully

More information

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force.

Tactile Switch. Ordering Information. A Wide Range of Models: 6 x 6 mm, 12 x 12 mm, Vertical, and High-force. Tactile Switch A Wide Range of Models: 6 x 6 mm, 1 x 1 mm, Vertical, and High-force. A positive click action plus a long life equal to that of a no-contact switch. Radial models (taping specifications)

More information

Limit Switches Matsushita Electric Works, Ltd. Matsushita Electric Works, Ltd. Limit Switches ARCT1B272E Please contact...

Limit Switches Matsushita Electric Works, Ltd. Matsushita Electric Works, Ltd. Limit Switches ARCT1B272E Please contact... 06 07 Limit Switches Limit Switches 06 07 Please contact... ARCT1B272E 200609-1YT These materials are printed on ECF pulp. These materials are printed with earth-friendly vegetable-based (soybean oil)

More information

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT NC NC RELAYS Flat type Flat type (PC board) (PC board) FEATURES 1. Compact, slim design Use of high-performance flat electromagnetic design achieves 10.9

More information

2NC (slow-action) Direct. Model. opening

2NC (slow-action) Direct. Model. opening Small Safety Limit Switch CSM DS_E_3_1 Smallest Class of Safety Limit Switches in the World Note: Contact your sales representative for details on models with safety standard certification. The world's

More information

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information with the World s Smallest Mounting Area Subminiature model as small as.2 (H). (W) (L) mm is ideal for high-density mounting ((U)-2F(-Y)). Low profile of.2 mm improves mounting efficiency ((U)-2F(-Y)).

More information

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend

D4NH. Model Number Structure. Safety-door Hinge Switch. Model Number Legend Safety-door Hinge Switch Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment Lineup includes three contact models with 2NC/1NO and 3NC contact forms

More information

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES

TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS YAMATAKE PROXIMITY SENSOR CATEGORIES TECHNICAL GUIDE FOR PROXIMITY SENSORS DEFINITIONS "" includes all sensors that detect the presence of a metallic object approaching the sensing face or near the sensing face without mechanical contact.

More information

Tactile Switch (Hinged Type)

Tactile Switch (Hinged Type) Tactile Switch (Hinged Type) Hinged Design Developed through Ergonomics Quick, superior snap action through hook-type hinge construction. Available with 1 or LEDs or without LEDs. The hinge button is available

More information

EX Series. Electric Actuators for Ball and Butterfly Valves

EX Series. Electric Actuators for Ball and Butterfly Valves EX Series Electric Actuators for Ball and Butterfly Valves Next-Generation Electric Actuator Realization of Upgraded General-Purpose Actuators The modularization and adoption of the common parts have brought

More information

1 Form A 5A small size power relay for interface

1 Form A 5A small size power relay for interface 1 Form A 5A small size power relay for interface PQ RELAYS RoHS compliant Protective construction: Sealed type FEATURES 1. Compact and slim 20 mm (L) mm (W) 16 mm (H).787 inch (L).394 inch (W).630 inch

More information

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2 Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.

More information

QL (AZ4) Micro Limit Switches

QL (AZ4) Micro Limit Switches SUMINITURE SIZE LIMIT SWITCHES QL (Z4) Micro Limit Switches High precision micro limit switches with excellent environment proofing Quickly upgraded to limit switches with lamps by mounting an LED lamp

More information

Miniature Pre-Leaded Vertical Enclosed Switches

Miniature Pre-Leaded Vertical Enclosed Switches Miniature Pre-Leaded Vertical Enclosed Switches 14CE Series Miniature enclosed switches with outstanding harsh environment resistance, ideal for compact machinery and equipment. Easy mounting by tightening

More information

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit SSR with Failure Detection Function Detects failures in SSRs used for heater temperature control and simultaneously outputs alarm signals. This product supports the safe design of heater control systems,

More information

MCF3 25CT Inrush-withstand

MCF3 25CT Inrush-withstand RoHS Pb Dimensions and construction: (mm) Case: End-cap substrate metal: End-cap primary plating: End-cap surface plating: Adhesive: Marking: Ceramic Copper t=0.25 mm Nickel plated, 0.5 μm or more Tin

More information

Reference Only. Inductance Frequency (μh) Tolerance Typ Max (MHz min.) 85 *

Reference Only. Inductance Frequency (μh) Tolerance Typ Max (MHz min.) 85 * P.1/10 CHIP COIL (CHIP INDUCTORS) LQM2HPN G0L REFERENCE SPECIFICATION 1. Scope This reference specification applies to LQM2HPN_G0 series, Chip Coil (Chip Inductors). 2. Part Numbering (ex) LQ M 2H P N

More information

Reference Only. *B: Bulk packing also available. Inductance. Tolerance M:±20% N:±30% 0.150±25% 1.0 * * N:±30% 0.23±25% 0.8 *2 0.

Reference Only. *B: Bulk packing also available. Inductance. Tolerance M:±20% N:±30% 0.150±25% 1.0 * * N:±30% 0.23±25% 0.8 *2 0. CHIP COIL (CHIP INDUCTORS) LQM21PN GRD REFERENCE SPECIFICATION P.1/9 1. Scope This reference specification applies to LQM21PN_GR series, Chip Coil (Chip Inductors). 2. Part Numbering (ex) LQ M 21 P N 1R

More information

HEAVY DUTY POWER RELAYS FEATURES

HEAVY DUTY POWER RELAYS FEATURES VDE VC HEAVY DUTY POWER RELAYS VC RELAYS Faston terminal Screw terminal mm 9 FEATURES VC power relays are designed for controlling heavy duty loads safely: Contact gap of 3 mm or more -point contacts for

More information

Limit Switches with Positive Opening Mechanism

Limit Switches with Positive Opening Mechanism Limit Switches with Positive Opening Mechanism LJA Series Positive opening mechanism Snap action limit switches with positive opening mechanism enables general industrial machines to comply with EC directives

More information

Miniature Limit Switches

Miniature Limit Switches (Horizontal) Plastic od 49.17.1* oller Lever 49.1.01.03 Miniature Limit witches 49 ealed oller Plunger 49 eries Miniature Limit witches Model election...1 Model Number tructure... Technical Data...3 pecification...4