Accurate to 0.1 NIST Traceable Advanced PID Algorithm USB Port Free datalogging/control software

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "Accurate to 0.1 NIST Traceable Advanced PID Algorithm USB Port Free datalogging/control software"

Transcription

1 Accurate to 0.1 NIST Traceable Advanced PID Algorithm USB Port Free datalogging/control software CONTROLLERS Serving the laboratory glassware industry for over 75 years

2 State-of-the-Art and Vacuum Controllers Ace Glass now offers the most advanced laboratory temperature controllers for virtually every application in your lab. From a simple temperature monitor to a full research-grade Quad unit with four fully independent channels, ACE can provide the answer and the best value for your application. Units are available in four different thermocouple types and temperature ranges. Controllers may be purchased with or without thermocouples, and the probe receptacles on each unit are color coded to match the thermocouple types they accept: blue = T ; yellow = K ; Black = J ; and white = RTD. All controllers have free control software that provides 0.1º C regulation of any lab device or piece of equipment. Included in this brochure is a portion of our wide offering of thermocouple probes, and our latest models for vacuum and pressure control, which feature free control software that can also provide data-logging capabilities. 230V versions are CE marked. Economy Controllers Ultra Compact, Ace Economy Controller with J, T, or K thermocouple inputs; output power 120 volt/60 Hz, 15 amp maximum. Bench or bar mountable. 120 volt/60 Hz input. Single-loop time proportional output: 10 seconds cycle rate. Solid state relay control contact. Accuracy over range: 0.25% (max 2 C). Set-point control accuracy: ± 0.1 C. Microprocessor-based 1/32 DIN module, dual process and set-point value display. Auto tuned PID with fuzzy logic. Programmable: ramp and soak (16 segment). Size: 2"x 5¼"x 5¼" (HxWxD); 120vac, 15 amps, Weight: 2 lbs, 2 oz. No 0 to 800 J No 200 to 250 T No 50 to 1200 K Model 150, J-Kem An ideal controller for applications that don t require the precise regulation of 200 Series controllers. This compact unit features 1200 watts of power, sufficient for heating 5 L mantles, many ovens, and other devices. Ramp-to-Set Point feature standard. USB port and data logging and control software optional. 2.5" x 3.75" x 5.25" (HxWxD) / 120vac, 10 amps, 1200 watts 150-T No 200 to 250 T J No 0 to 800 J K No 50 to 1200 K T-S Yes 200 to 250 T J-S Yes 0 to 800 J K-S Yes 50 to 1200 K Model 150/Timer, J-Kem Same power and versatility as the Model 150, but with a 100-hour digital timer to turn heating ON or OFF at a user-specified time. 2.5" x 4.75" x 5.5" (HxWxD) / 120vac, 10 amps, 1200 watts 150/Timer-T No 200 to 250 T /Timer-J No 0 to 800 J /Timer-K No 50 to 1200 K /Timer-T-S Yes 200 to 250 T /Timer-J-S Yes 0 to 800 J /Timer-K-S Yes 50 to 1200 K

3 Single-Channel Controllers Model 210, J-Kem The Model 210 is our most compact research grade controller, yet packed with 1200 watts of power. Sufficient for heating mantles up to 5 L in size, and most laboratory ovens, hot plates, reaction blocks and other heaters. Comes complete with USB port and data logging and control software. Power control computer provides 0.1 C regulation of anything. 3.25" x 5.25" x 7.25" (HxWxD) / 10 amps, 1200 watts. 210-T No 200 to 250 T J No 0 to 800 J K No 50 to 1200 K T-S Yes 200 to 250 T J-S Yes 0 to 800 J K-S Yes 50 to 1200 K Model 310, J-Kem 230V, CE-marked version of Model 210, above. w/ Sensor Cord 310-T-S Yes 200 to 250 T J-S Yes 0 to 800 J K-S Yes 50 to 1200 K Model 210/Timer, J-Kem Same power and versatility as the Model 210, above, but also contains a 100-hour digital timer to turn heating OFF or ON at a user-specified time. A new safety feature automatically disconnects power from the heater following recovery from a power failure. Comes complete with USB port and data logging and control software. Power control computer provides 0.1 C regulation of anything. 3.5" x 6.75" x 6" (HxWxD) / 120vac, 10 amps, 1200 watts. 210/Timer-T No 200 to 250 T /Timer-J No 0 to 800 J /Timer-K No 50 to 1200 K /Timer-T-S Yes 200 to 250 T /Timer-J-S Yes 0 to 800 J /Timer-K-S Yes 50 to 1200 K Model 250, J-Kem The Model 250 has both heating and cooling outlets for maximum versatility. Two heating outlets supply 1800 watts of power for large equipment and heating mantles up to 22 L. The third outlet, also 1800 watts and normally used for cooling, is programmable to provide power above, below, or at the set point. Comes complete with USB port and data logging and control software. Power control computer provides 0.1 C regulation of anything. 3.5" x 7.75" x 9.25" (HxWxD) / 120vac, 15 amps, 1800 watts. 250-T No 200 to 250 T J No 0 to 800 J K No 50 to 1200 K T-S Yes 200 to 250 T J-S Yes 0 to 800 J K-S Yes 50 to 1200 K

4 12318 Model 260/Timer, J-Kem The Model 260/Timer disconnects output power if the process temp exceeds the setpoint by a user specified amount or following a recovery from a power failure. Overtemp is signaled by both a lamp an an audible alarm. Features a 100 hour timer, two power outlets and 0.1º C regulation of anything. NIST traceable, USB port and free data logging and control software. 3.5" x 7.75" x 9.25" (HxWxD) / 15 amps, 1800 watts. VAC 260/Timer-J 120 No 0 to 800 J /Timer-K 120 No 50 to 1200 K /Timer-T 120 No 200 to 250 T /Timer-J-S 120 Yes 0 to 800 J /Timer-K-S 120 Yes 50 to 1200 K /Timer-T-S 120 Yes 200 to 250 T Model 360/Timer, J-Kem 230V, CE-marked version of Model 260/Timer, above. 360/Timer-J-S Yes 0 to 800 J /Timer-K-S Yes 50 to 1200 K /Timer-T-S Yes 200 to 250 T High Safety Controller Model 270, J-Kem Designed for processes requiring uncompromising safety. The only temperature controller available with a built-in, independent backup controller to guard against heating accidents resulting from equipment failure. The desired temperature is entered into the main temperature controller, which regulates heating, and then a high-temperature cut-off is entered into the backup limit controller. If the reaction reaches the high-temperature limit, or if a thermocouple should break, power is turned off to the heater until the controller is manually reset. Both meters independently monitor the reaction temperature. In the event that one meter fails, the other takes over to prevent a heating accident. Provides 100% redundant control. 3.75" x 7.75" x 9.25" (HxWxD) / 120vac, 15 amps, 1800 watts total watts maximum per channel. 270-T No 200 to 250 T J No 0 to 800 J K No 50 to 1200 K T-S Two of each 200 to 250 T J-S Two of each 0 to 800 J K-S Two of each 50 to 1200 K The Model 270 Series units noted above each come with two thermocouple sensors, two cords and two adapters. 4

5 Multi-Channel Controllers Gemini Series, J-Kem The Gemini Series features two temperature controllers in a single cabinet to regulate two independent reactions. This versatile controller has high-power outlets and a 100-hour digital timer (on channel one) to turn heating on or off at a user-entered time. Features include: over-temperature protection circuit with audible alarms; dual temperature displays; selectable operating modes; twin circuit breakers; and 100% solid-state design. 3.75" x 7.75" x 9.25" (HxWxD) / 120vac, 15 amps, 1800 watts total watts maximum per channel. Gemini-T No 200 to 250 T Gemini-J No 0 to 800 J Gemini-K No 50 to 1200 K Gemini-T-S Two of each 200 to 250 T Gemini-J-S Two of each 0 to 800 J Gemini-K-S Two of each 50 to 1200 K Gemini Series, J-Kem 230V, CE-marked version of Gemini Series, above. Gemini-T-S-230 Yes 200 to 250 T Gemini-J-S-230 Yes 0 to 800 J Gemini-K-S-230 Yes 50 to 1200 K Apollo Series, J-Kem Has all the features of the Gemini series, above, but also features an independent 100-hour digital timer on each controller channel. 4" x 8" x 9" (HxWxD) / 120vac, 15 amps, 1800 watts total watts maximum per channel. Apollo-T No 200 to 250 T Apollo-J No 0 to 800 J Apollo-K No 50 to 1200 K Apollo-T-S Two of each 200 to 250 T Apollo-J-S Two of each 0 to 800 J Apollo-K-S Two of each 50 to 1200 K The Apollo and Gemini Series units noted above each come with two thermocouple sensors, two cords and two adapters Quad Series, J-Kem The Quad is your solution when bench space is at a premium the Quad packs four independent temperature controllers into a single unit! Each of the four controller channels has 1200 watts of power, an independent display, and an over-temperature protection circuit. 5.25" x 7" x 7.5" (HxWxD) / 120vac, 15 amps, 1800 watts total watts maximum per channel. Quad-T No 200 to 250 T Quad-J No 0 to 800 J Quad-K No 50 to 1200 K Quad-T-S Four of each 200 to 250 T Quad-J-S Four of each 0 to 800 J Quad-K-S Four of each 50 to 1200 K The Quad Series units noted above each come with four thermocouple sensors, four cords and four adapters. 5

6 High Power Controller Model HCC, J-Kem The HCC line of controllers are designed to power large-scale equipment with volumes up to 100 liters. Built with the same commitment to safety as our controller, the HCC Series features a built-in, independent backup controller to guard against heating accidents resulting from equipment failure. The desired temperature is entered into the main temperature controller, which regulates heating, and then a high-temperature cut-off is entered into the backup limit controller. If the reaction reaches the high-temperature limit, or if a thermocouple should break, power is turned off to the heater until the controller is manually reset. Both meters independently monitor the reaction temperature. In the event that one meter fails, the other takes over to prevent a heating accident. Provides 100% redundant control. These highpower controllers also incorporate a 100-hour timer to turn heating ON or OFF at a user-specified time. Comes complete with USB port and data logging and control software. Power control computer provides 0.1 C regulation of anything. Requires sensor (not included) for operation. 230V version available via special order. 5.5" x 12" x 12.5" (HxWxD) / 130 amps, 3600 watts Instatherm Controller VAC HCC-130-T No 200 to 250 T HCC-130-J No 0 to 800 J HCC-130-K No 50 to 1200 K Model 410, J-Kem The Model 410 is designed for heaters that cannot be operated at 120VAC. This makes the unit perfect for use with many of our Ace Instatherm oil baths. Maximum output voltage of the Model 410 is selected using the power output knob on the front of the controller. Selectable output voltage limit provides precise power and temperature control while protecting low voltage heaters. Comes complete with USB port and data logging and control software. Power control computer provides 0.1 C regulation of anything. 3.25" x 5.25" x 7.25" (HxWxD) / 10, 20, 40, 60, 120 vac, 10 amps, 1200 watts 410-T No 200 to 250 T J No 0 to 800 J K No 50 to 1200 K T-S Yes 200 to 250 T J-S Yes 0 to 800 J K-S Yes 50 to 1200 K Instatherm Bath Kit 9601 Instatherm Bath Kit, Ace/J-Kem Consists of one each and bath, plus one Digital Controller with one J Sensor and controller cord. 120V

7 / Sensors For J-Kem Controllers T- Sensors T thermocouple temperature sensors for use with all J-Kem T model temperature controllers. Either 1/4- or 1/8-inch O.D. Available in 304 stainless steel or PTFE coated stainless steel sheaths of various lengths. O.D. PTFE Coated? 1/8 6 No /8 12 No /8 18 No /8 24 No /8 36 No /8 6 Yes /8 12 Yes /8 18 Yes /8 24 Yes /8 36 Yes /4 6 No /4 12 No /4 18 No /4 24 No /4 36 No /4 6 Yes /4 12 Yes /4 18 Yes /4 24 Yes /4 36 Yes J- Sensors J thermocouple temperature sensors for use with all J-Kem J model temperature controllers. Either 1/4- or 1/8-inch O.D. Available in 304 stainless steel or PTFE coated stainless steel sheaths of various lengths. O.D. PTFE Coated? 1/8 6 No /8 12 No /8 18 No /8 24 No /8 6 Yes /8 12 Yes /8 18 Yes /8 24 Yes /8 36 Yes /4 6 No /4 12 No /4 18 No /4 24 No /4 36 No /4 6 Yes /4 12 Yes /4 18 Yes /4 24 Yes /4 36 Yes K- Sensors K thermocouple temperature sensors for use with all J-Kem K model temperature controllers. Either 1/4- or 1/8-inch O.D. Available in 304 stainless steel or PTFE coated stainless steel sheaths of various lengths. O.D. PTFE Coated? 1/8 6 No /8 12 No /8 18 No /8 24 No /8 36 No /8 6 Yes /8 12 Yes /8 18 Yes /8 24 Yes /8 36 Yes /4 6 No /4 12 No /4 18 No /4 24 No /4 36 No /4 6 Yes /4 12 Yes /4 18 Yes /4 24 Yes /4 36 Yes For extension cords, see Ace straight and coiled cords, on the following page. 7

8 Sensor extension cords for use with all J-Kem thermocouple probes. Cords match color of probe type, blue, black, yellow or white. Available in either 10- or 20-foot coiled or straight styles. Select length, type, and connector, SMP (flat plug) or OST (round plug). OST (Standard) SMP (Mini) Sensor Cords Coiled Probe Style (ft.) Connector J 10 SMP K 10 SMP T 10 SMP RTD 10 SMP J 10 OST K 10 OST T 10 OST J 20 SMP K 20 SMP T 20 SMP J 20 OST K 20 OST T 20 OST Dual Sensor Cords Dual element extension cords for use with dual element sensors for J-Kem models HCC and 270 temperature controllers. Available in T, K, and J types in 10- or 25-ft. lengths. Probe Style (ft.) T J K T J K Sensor Cords Straight Probe Style (ft.) Connector J 10 SMP K 10 SMP T 10 SMP J 10 OST K 10 OST T 10 OST RTD 10 OST J 20 SMP K 20 SMP T 20 SMP J 20 OST K 20 OST T 20 OST Dual Sensors PTFE Coated Dual coupling temperature thermocouple sensors for use with Model HCC and 270 J-Kem temperature controllers. Available in J, T or K types. Probes are PTFE coated stainless steel in various lengths and O.D. Probes require extension cords. O.D. Sensor 1/8 12 T /4 12 T /4 24 T /4 36 T /8 12 J /4 12 J /4 24 J /4 36 J /8 12 K /4 12 K /4 24 K /4 36 K

9 12185 Wire Sensors Flexible 30-gauge thin wire thermocouple. Ideal for small volumes and hard-to-reach spots. Can be used with heating mantles, hotplates, inside of heating equipment and for small surface measurement. Can be inserted through rubber septum for an airtight seal. Available in standard connections, and in 36- and 72-inch lengths. PTFE Coated? Sensor Yes 36 T Yes 36 K No 72 T No 72 K No 72 J Monitor Needle-Tip Sensors Needle-tip, 17-gauge thermocouple sensor for measurement and control of very small volumes and in small systems. Sensors come coated and uncoated in 3.5- or 7-in. lengths. Actual temperature measure is at first 2mm of the probe and must have liquid contact for accurate readings. May be inserted through rubber septa 9107 or 9106 for air-tight seal. Comes with 72-in. PTFE wire extension. Available in T, K, or J type connections. PTFE Coated? Sensor Yes 3.5 T Yes 7.0 T Yes 3.5 K Yes 7.0 K Yes 3.5 J Yes 7.0 J No 3.5 T No 7.0 T No 3.5 K No 7.0 K No 3.5 J No 7.0 J Digital Monitor Monitors and displays the temperature of an attached piece of equipment on a bright LED display. Built-in USB port and free data logging software allows remote temperature monitoring, and provides a GMP, GLP compliant temperature history. is not included. 2.5" x 4.75" x 5.5" (HxWxD) / 50 watts, USB 2.0. DM120-T 200 to 250 T DM120-J 0 to 800 J DM120-K 50 to 1200 K Digital Monitor 230V, CE-marked version of Digital Monitor, above. DM230-T 200 to 250 T DM230-J 0 to 800 J DM230-K 50 to 1200 K

10 Vacuum Regulators Precision Vacuum Regulator, J-Kem Perfect for vacuum distillation, unit automatically compensates for leaks in the equipment under test and maintains precise pressure, even in systems with a continuous gas purge. This computer (built-in) controlled vacuum regulator maintains pressure in the range of 0.1 to 760 Torr (atm pressure) in test instruments with volumes as small as 1 ml. Standard features include 16-step programmable pressure ramp and serial communications for PC control and data logging. DVR Specifications: Transducer Diaphragm: Stainless Steel Accuracy: 0.1% Proof Pressure: 200% Controller Regulation: Resolution: Vapor Path Materials: Ramp Rates: Serial Communications: 0.015% of range 0.1 Torr of 0.01 psi Stainless steel and PTFE 100 Torr/sec to 0.1 Torr/hr. RS232 (RS485 or USB on request) Stainless Steel Proportioning Valves Select one for use with Digital Vacuum Regulator , above. For Reactor Volumes Cv Orifice Size PSV-2 1 ml to 2 L in PSV-3 25 ml to 4 L in PSV ml to 22 L in PSV-5 1 L to 50 L in PSV-6 Large Capacity in PSV-7 Large Capacity in PSV-8 Large Capacity in PSV-9 Large Capacity in DVR-PNV Stainless Steel Needle Valve, improves regulation

11 Connect to any vacuum pump or vacuum source, and then to any piece of equipment, to regulate pressure, in most cases to ±1 Torr. A standard pressure ramp feature evacuates equipment at a user-defined rate to eliminate bumping due to solvent degassing or over-evacuation. Ideally suited for large volume distillations, rotary evporators and vacuum chambers. Not recommended for small volume distillations or applications which involve a continuous purge with gas Vacuum Regulator No Mercury Designed for vacuum systems that run continuously, such as oil-filled vacuum pumps, aspirators, or with systems that are always on, like in-house vacuum systems. The unit regulates pressure by opening and closing a valve that separates the vacuum source from the system being evacuated. DVR Vacuum Regulator No Mercury 230V, CE-marked version of DVR-200 Vacuum Regulator, above. DVR Vacuum Regulator No Mercury Designed for use with diaphragm vacuum pumps. In some systems, pressure is regulated by turning the vacuum pump itself on and off. This unit extends the life of diaphragm pumps by never forcing the pump to start against an established vacuum, which can increase pump life by 100%. DVR Vacuum Regulator No Mercury 230V, CE-marked version of DVR-280 Vacuum Regulator, above. DVR Digital Vacuum Monitor Continuous, no regulation, Not pictured. DVM Digital Vacuum Monitor 230V, CE-marked version of DVM-100 Digital Vacuum Monitor, above. Recovers >99% of solvent from rotary evaporators Solvent DVR Pressure (mm Hg) Solvent Volume Time To Dryness Percent Recovery Ether 475 Torr 340 ml 14.6 min. 99.6% CH 2 CI Torr 360 ml 21.9 min. 99.8% CH 2 CI Torr 255 ml 5.9 min. 99.5% EtOAc 90 Torr 316 ml 17.0 min. 99.9% Toluene 50 Torr 273 ml 15.7 Min. 99.4% DVM V versions are CE marked 11

12 Water Flow Monitors/Controllers Model LS-120 Lab Safety Controller, J-Kem Lab safety controller by J-Kem combines all the features of the Digital Monitor and the Water-Flow Monitor into a single versatile instrument. Plug any piece of equipment into the monitor, then if the water flow rate falls below the set level, or if the reaction temperature goes above or below the user set limits, the outlet power turns off automatically. The unit will also cut off power if the main power is interrupted. The controller then has to be reset. See Ace product family for flow sensors. With Sensor Cord LS-120-T No 200 to 250 T LS-120-J No 0 to 800 J LS-120-K No 50 to 1200 K Description Flow Rate, LPM WFM-01 Flow Sensor 0.1 to WFM-02 Flow Sensor 1 to WFM-03 Flow Sensor 2 to Shut-Off Valve Model WFM-120 Water Flow Monitor, J-Kem J-Kem monitor precisely measures the flow of water through a condenser, bath or a photochemical reactor. Upon interruption or if the flow drops below an operator set rate, power to the monitored equipment is cutoff. Manual power reset. Inclusion of a shut-off valve and either a audible alarm or a digital alarm is recommended. Description Flow Rate, LPM WFM-01 Flow Sensor 0.1 to WFM-02 Flow Sensor 1 to WFM-03 Flow Sensor 2 to Shut-Off Valve WFM-120 Water Flow Monitor Alarm, J-Kem Digital alarm outlet and audible alarm accessories for J-Kem safety controller and water-flow monitors. Allows and units to be set up for alarm warnings when in unsafe conditions. The audible alarm sounds during low or no water conditions for the monitor and the digital alarm activates on either the water flow monitor or the safety controller when conditions are out of set ranges. For Controllers Alarm WFM-AA & Digital WFM-OC Audible CONTROLLERS P.O. Box 688 Vineland, NJ Fax: TOLL-FREE: FAX:

The Safest Heating Method!

The Safest Heating Method! ACE Instatherm For Glass Vessels The Safest Heating Method! Borosilicate Glass Eliminate the need for heating tapes, immersion heaters and heating mantles. Instatherm is a safer, more precise heating method

More information

Vacuum Gauge Catalog

Vacuum Gauge Catalog 2019 Vacuum Gauge Catalog Possibly The World s Best Gauge Tubes! 1/8 in. NPT Standard Internal Volume Only 0.78 cc Working Pressure to 300 PSI (Tested to 1200 PSI) NO PLASTIC! Pirani Gauges 1 to 2000 mtorr.01

More information

Varian, Inc. Vacuum Technologies. TPS Turbo Pumping Systems. Features and Benefits 2-3. Mini-TASK AG TPS-compact 6-7

Varian, Inc. Vacuum Technologies. TPS Turbo Pumping Systems. Features and Benefits 2-3. Mini-TASK AG TPS-compact 6-7 Varian, Inc. Vacuum Technologies TPS Turbo Pumping Systems Features and Benefits 2-3 Mini-TASK AG81 4-5 TPS-compact 6-7 TPS-mobile and TPS-bench 8-10 TPS Turbo Pumping Systems Features and Benefits The

More information

4, 6, 8 & 11 Su p e r Ev a c Vacuum Pumps

4, 6, 8 & 11 Su p e r Ev a c Vacuum Pumps SuperEva c Vacuum Pump Systems hose adapters, valves and Parts vacuum and hoses Recovery YELLOW JACKET 4, 6, 8 & 11 Su p e r Ev a c Vacuum Pumps Pulls a deep vacuum of 15 microns or better, protecting

More information

Stirred Reactors and Pressure Vessels

Stirred Reactors and Pressure Vessels P a r r I n s t r u m e n t C o m p a n y Stirred Reactors and Pressure Vessels Designing and Building Quality Pressure Apparatus for Over 100 Years Bulletin 4500 Volume 14 Start Chapter Eight This pdf

More information

AMI. American Magnetics, Inc. Excellence in Magnetics and Cryogenics

AMI. American Magnetics, Inc. Excellence in Magnetics and Cryogenics Cryogenic Liquid Level Instruments Versatile Reliable Affordable AMI American Magnetics, Inc. Excellence in Magnetics and Cryogenics A Versatile Level Measurement System... A Variety of Liquids Nitrogen

More information

Mixer/Temperature Control

Mixer/Temperature Control Mixer/Temperature Control Dry Bath, Incubator, Shaker, Stirring Water Bath Major Science designs and manufactures a comprehensive range of mixing and temperature control equipments for use in the fields

More information

FN Series Scalable N+1 UPS 3kVA to 24kVA Rackmount

FN Series Scalable N+1 UPS 3kVA to 24kVA Rackmount FN Series Scalable N+ UPS kva to kva Rackmount Advanced Features: * Parallel Rackmount Units with a Single of up to kva * True N+ Redundancy * ECO Mode: 97% Efficiency * DSP Double-Conversion On-line Sinewave

More information

7526A Precision Process Calibrator. Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument

7526A Precision Process Calibrator. Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument 7526A Precision Process Calibrator Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument The 7526A Precision Process Calibrator calibrates a wide range of pressure

More information

1291BL Series Technical Specification Single-Axis Rate and Positioning Table System

1291BL Series Technical Specification Single-Axis Rate and Positioning Table System Datasheet 1291BL Series Technical Specification Single-Axis Rate and Positioning Table System DESCRIPTION The Model 1291BL Single Axis Positioning and Rate Table System is designed to provide precise position,

More information

B BASIC HEAT TREATMENT CONSOLE

B BASIC HEAT TREATMENT CONSOLE Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL

More information

FCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications

FCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications FCI ST50 Series Flowmeters Low Cost, Low Maintenance ir, Compressed ir and Nitrogen Flow Measurement for Process and Plant pplications Wastewater Treatment eration Control lower and Dryer ir Flow Control

More information

Installation Instructions for: Channel Thermocouple Amplifier

Installation Instructions for: Channel Thermocouple Amplifier Installation Instructions for: 30-2204 4 Channel Thermocouple Amplifier WARNING: This installation is not fo r the electrically or mechanically challenged! Use this sensor with EXTREME caution! If you

More information

Stirred Reactors and Pressure Vessels

Stirred Reactors and Pressure Vessels P a r r I n s t r u m e n t C o m p a n y Stirred Reactors and Pressure Vessels Designing and Building Quality Pressure Apparatus for Over 100 Years Bulletin 4500 Volume 14 Start Chapter Two This pdf is

More information

6. Document tasks performed during visit and report any observations to the appropriate

6. Document tasks performed during visit and report any observations to the appropriate Chiller Annual Maintenance RFP Attachment B Services Required Tasking: Vibration Analysis 1. All work shall be performed in accordance with safety policies 2. Check with appropriate customer representative

More information

Model 30GCE Low-Temp Oven POWER. Switch opening. View Setpoint Increase Setpoint Decrease Setpoint (3 sec.) Enter/Exit Menu Levels GCE SERIES

Model 30GCE Low-Temp Oven POWER. Switch opening. View Setpoint Increase Setpoint Decrease Setpoint (3 sec.) Enter/Exit Menu Levels GCE SERIES Model AFE - LT Low-Temp Series Ovens With Microprocessor Control & Digital Display OPERATING MANUAL Standard Contents (1) AFE Series Low-Temp Oven (2) Adjustable chrome wire shelf (4) Shelf brackets Model

More information

SGO Series. SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 SGO5

SGO Series. SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 SGO5 SGO Series SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 Ideal for Industrial, Analytical, and General Laboratory Applications SHEL LAB Gravity Convention Laboratory Ovens are recommended for

More information

Myers Vacuum 1155 Myers Lane Kittanning, PA Phone: Fax: Instruction Manual For Thermocouple Vacuum Gauge GTC-390

Myers Vacuum 1155 Myers Lane Kittanning, PA Phone: Fax: Instruction Manual For Thermocouple Vacuum Gauge GTC-390 1155 Myers Lane Kittanning, PA 16201 Phone: 724-545-8331 Fax: 724-545-8332 For Thermocouple Vacuum Gauge TABLE OF CONTENTS SECTION DESCRIPTION 1.0 INTRODUCTION 1.1 Product Description 1.2 Operating Principles

More information

ValveMate 7000 Controller Operating Manual

ValveMate 7000 Controller Operating Manual A NORDSON COMPANY ValveMate 7000 Controller Operating Manual Steady Test Clear Time Set Fast Slow POWER RUN SETUP CYCLE A NORDSON COMPANY VALVEMATE 7000 Run Setup Purge Program Fast Slow Time Set Pressure

More information

348002K/348012K Manifold Block Style Service Manual 12/2000

348002K/348012K Manifold Block Style Service Manual 12/2000 348002K/348012K Manifold Block Style Service Manual 12/2000 Service Manual 348002K/348012K Manifold Block Style Recovery/Recycling/Recharging Unit For R-12 or R-134a Only TABLE OF CONTENTS: Theory of Operation

More information

Valve Solutions. Downstream Pressure Controllers and Valves PRODUCT SELECTION GUIDE TYPES 651, 1651, 153, 253, 653, AND HEATED VALVES

Valve Solutions. Downstream Pressure Controllers and Valves PRODUCT SELECTION GUIDE TYPES 651, 1651, 153, 253, 653, AND HEATED VALVES Valve Solutions W W W. M K S I N S T. C O M Downstream Pressure Controllers and Valves PRODUCT SELECTION GUIDE TYPES 651, 1651, 153, 253, 653, AND HEATED VALVES Downstream Pressure Controllers and Valves

More information

Operators Manual. Microprocessor Controlled Water Baths /98

Operators Manual. Microprocessor Controlled Water Baths /98 Operators Manual Microprocessor Controlled Water Baths 110-012 7/98 Table Of Contents Section 1 - General Information 1.1 Warranty 1.2 Unpacking 1.3 Package Contents 1.4 Description Section 2 - Set Up

More information

WB 23 & WB 27. High-Speed Eddy-Current Dynamometers WB 23 & WB 27. Features. Description. Operating principles

WB 23 & WB 27. High-Speed Eddy-Current Dynamometers WB 23 & WB 27. Features. Description. Operating principles WB 23 & WB 27 High-Speed Eddy-Current Dynamometers Magtrol offers 3 types of dynamometer brakes to absorb load: Hysteresis, Eddy-Current and Magnetic Powder. Each type of Dynamometer has advantages and

More information

Stirred Reactors and Pressure Vessels

Stirred Reactors and Pressure Vessels Chapter 2 Stirred Reactors Inside this chapter you will find: REACTOR SELECTION GUIDE 4520 BENCH TOP, 1000 & 2000 ml 4520 HP BENCH TOP, 970 & 1900 ml 4530 MOVEABLE CART OR FLOOR STAND, 1000 & 2000 ml 4530

More information

SECTION 8: STATOR WINDING SENSORS

SECTION 8: STATOR WINDING SENSORS SECTION 8: STATOR WINDING SENSORS Install between stator windings for continuous protection of motors and generators Increased safety sensors for use in hazardous areas Single and dual elements offer high

More information

GS2 Series - Introduction

GS2 Series - Introduction GS2 Series - Introduction GS2 Series Drives Rating Hp.25.5 1 2 3 5 7.5 10 kw 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 Single-Phase 115 Volt Class Single/Three-Phase 230 Volt Class Three-Phase 230 Volt Class Three-Phase

More information

ISO-9001:2008 HOT PLATES CATALOG. Phone: Fax: Web:

ISO-9001:2008 HOT PLATES CATALOG. Phone: Fax: Web: ISO-9001:2008 HOT PLATES CATALOG Phone: 281 496 0900 Fax: 281 496 0400 Email: sales@expotechusa.com Web: www.expotechusa.com 32 Digital Feature international symbols for easy recognition by all operators

More information

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT SERIES Features Full Port 16 Stainless Steel ball valve LED light gives continuous status indication IP67 weatherproof polyamide

More information

Procedure for Koehler Digital Constant Temperature Viscosity Bath

Procedure for Koehler Digital Constant Temperature Viscosity Bath Procedure for Koehler Digital Constant Temperature Viscosity Bath Intro: This unit is designed to perform kinematic viscosity tests using glass capillary viscometers, for this lab you will be using Cannon-Fenske

More information

WOB-L. PISTON Pumps and Compressors. 607/668/669/688/689 Series MODELS:

WOB-L. PISTON Pumps and Compressors. 607/668/669/688/689 Series MODELS: WOB-L PISTON Pumps and Compressors 607/668/669/688/689 Series MODELS: Standard models available. 607CA22, 607CA32, 607CD22, 607CD32 668CE44, 668CGHI44 688CE44, 688CGHI44 669CE44, 669CHGI44 689CE44, 689CGHI44

More information

Paralleling Equipment

Paralleling Equipment Paralleling Equipment PowerCommand Model 300 Digital Master Control Description The PowerCommand TM Digital MasterControl is a microprocessor-based paralleling system component, designed to directly interface

More information

An IDEX Water & Wastewater Business. pulsafeeder.com. Boiler. Programmable Boiler Controller

An IDEX Water & Wastewater Business. pulsafeeder.com. Boiler. Programmable Boiler Controller An IDEX Water & Wastewater Business pulsafeeder.com Boiler Programmable Boiler Controller Pulsafeeder Expertise Technology is the key to delivering responsible products to the markets that we serve. Leading

More information

HUMIDITY / TEMPERATURE TRANSMITTER

HUMIDITY / TEMPERATURE TRANSMITTER HUMIDITY / TEMPERATURE TRANSMITTER SEM161, SEM16 CONFIGURATION USING USB PORT POWERED CONFIGURATOR HUMIDITY, TEMPERATURE, DEW POINT MEASUREMENT INTERCHANGEABLE DIGITAL SENSOR HIGH ACCURACY AND STABILITY

More information

Vission 20/20 micro-controller. Operation and service manual Version 2.6

Vission 20/20 micro-controller. Operation and service manual Version 2.6 Vission 20/20 micro-controller Operation and service manual Version 2.6 Important Message READ CAREFULLY BEFORE OPERATING YOUR COMPRESSOR. The following instructions have been prepared to assist in operation

More information

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications DIN-Rail DC UPS Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications Combines all system power functions: power supply, battery charger, UPS circuitry

More information

BARNSTEAD THERMOLYNE CORPORATION MEL-TEMP 3.0 OPERATING INSTRUCTIONS. Model No LT1186X4 5/1/00

BARNSTEAD THERMOLYNE CORPORATION MEL-TEMP 3.0 OPERATING INSTRUCTIONS. Model No LT1186X4 5/1/00 BARNSTEAD THERMOLYNE CORPORATION MEL-TEMP 3.0 OPERATING INSTRUCTIONS Model No. 1401 1402 LT1186X4 5/1/00 Table of Contents Safety Information...3 Alert Signals...3 Intended Use...3 General Usage...3 Warnings...3

More information

Mistral LC-MS Evolution Specification

Mistral LC-MS Evolution Specification Mistral LC-MS Evolution Specification Flow Rate: Outlet Pressure: Purity : Power Consumption : Circuit Breaker: Pressure accuracy : Microprocessor controlled display : Operating conditions : temperature

More information

2006/2007 Product Catalog. The World s Leading SOLAR Controllers

2006/2007 Product Catalog. The World s Leading SOLAR Controllers 2006/2007 Product Catalog The World s Leading SOLAR Controllers OUR COMPANY Morningstar Corporation, founded in 1993, is the world s leading supplier of photovoltaic (PV) controllers. In 2005 we shipped

More information

LUBRICATING OILS. Test Methods

LUBRICATING OILS.  Test Methods LUBRICATING OILS s Page Foaming Characteristics of Lubricating Oils ASTM D892, D6082; IP 146; DIN 51566; FTM 791-3211, 791-3213...108-110 Water Separability of Petroleum Oils and Synthetic Fluids ASTM

More information

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology VALVE CONTROLLERS Controllers for Dust Extraction 2010 Technology / 2011 Valve controllers for all cases HESCH has the skills and technology to tackle any control task for dedusting of filter and dust

More information

VACUUM CONTROL SPI-MODULE INSTRUCTION MANUAL

VACUUM CONTROL SPI-MODULE INSTRUCTION MANUAL SUPPLIES R VACUUM CONTROL TM SPI-MODULE INSTRUCTION MANUAL SPI Supplies Division of STRUCTURE PROBE, inc. 69 East Gay Street, P.O. 66, West Chester, PA 1981-066 (610) 46 400 Fax: (610) 46-7 E-Mail SPISPI@SPI.com

More information

Komatsu Power Generation Systems

Komatsu Power Generation Systems Komatsu Power Generation Systems Komatsu Air-to-Air aftercooled engine Advanced Air-to-Air aftercooled Engines have been introduced. EGS Series Generators are mounted with Komatsu engines that have High

More information

Application Engineering

Application Engineering Application Engineering February, 2009 Copeland Digital Compressor Controller Introduction The Digital Compressor Controller is the electronics interface between the Copeland Scroll Digital Compressor

More information

Engel Injection Molding Machine VERTICAL CLAMP INSERT 330V/90 WP US. Data Sheet INSERT 330V/90 WP US - VERTICAL CLAMP / VERTICAL INJECTION

Engel Injection Molding Machine VERTICAL CLAMP INSERT 330V/90 WP US. Data Sheet INSERT 330V/90 WP US - VERTICAL CLAMP / VERTICAL INJECTION Engel Injection Molding Machine INSERT 330V/90 WP US - VERTICAL CLAMP / VERTICAL INJECTION CLAMP Clamp force US tons 90 Clamp opening force US tons 3.0 Clamp stroke (max.) inches 13.78 Mold height (min

More information

OIL-FREE, ROTARY SCREW AIR COMPRESSORS Two-stage, Air-cooled and Water-cooled Fixed Speed or VFD

OIL-FREE, ROTARY SCREW AIR COMPRESSORS Two-stage, Air-cooled and Water-cooled Fixed Speed or VFD OIL-FREE, ROTARY SCREW AIR COMPRESSORS Two-stage, Air-cooled and Water-cooled Fixed Speed or VFD 40-500 HP 170-2400 SCFM 40-150 PSIG www.knw-series.com High Quality, Quiet and Energy Efficient Both compression

More information

emp. & Humid. Chambers

emp. & Humid. Chambers T emp. & Humid. Chambers was established in 1988 with the goal of delivering the best laboratory equipments for the reliable results. We always strive to develop high technology with ergonomic design for

More information

Miniature Inert PTFE Isolation Valves. Physical Properties Electrical Performance Characteristics

Miniature Inert PTFE Isolation Valves. Physical Properties Electrical Performance Characteristics 2-Way and 3-Way Solenoid Valves Typical Applications Reagent Control Solvent Management Aggressive Liquid Control Product Specifications Valve Type: Diaphragm Isolation Valve Valve Configuration: 3-Way

More information

PARTS LIST. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

PARTS LIST. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800) 1/2 SIZE CONVECTION TJ CINNAMON MCO-E-5 PARTS LIST Toll Free Phone, (US & Canada): (800) 427-6668 Toll Free Fax, (US & Canada): (800) 361-7745 http://www.garland-group.com TJ Cinnamon Oven (Rev 01) Page

More information

Manual Kinematic Viscosity Bath Tamson TV12

Manual Kinematic Viscosity Bath Tamson TV12 Manual Kinematic Viscosity Bath Tamson Rev 1.05 1 Viscosity Business Today Testing kerosene Testing diesel Testing lubricants Testing fuel oils Testing residues Testing bituminous or asphalt samples Testing

More information

Lubricating Oils. Test Methods

Lubricating Oils.  Test Methods Lubricating Oils s Page Foaming Characteristics of Lubricating Oils ASTM D892, D6082; IP 146; DIN 51566; FTM 791-3211, 791-3213...108-110 Water Separability of Petroleum Oils and Synthetic Fluids ASTM

More information

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors Model 8610C Gas Chromatograph Mounts up to Six Detectors and Five Injectors Ambient to 400 C Temperature Programmable Column Ovens Dimensions: 19 wide x 13.5 high x 14.5 deep Implement virtually any EPA

More information

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit. CHAPTER 17 4 Electric Circuits SECTION Introduction to Electricity BEFORE YOU READ After you read this section, you should be able to answer these questions: What are the three main parts of a circuit?

More information

TELEDYNE HASTINGS INSTRUMENTS

TELEDYNE HASTINGS INSTRUMENTS DAVC-4 DAVC-6 FEATURES www.disensors.com TELEDYNE HASTINGS INSTRUMENTS Operates Hastings Instruments Most Popular DV-4 and DV-6 Gauge Tubes Ranges: DV-6 (1 999 mtorr) DV-4 (0.02 20 Torr) Direct Replacement

More information

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase ILLUMINATOR LV Emergency Lighting Inverter System 175VA through 750VA Illuminator Series LV Single Phase ILLUMINATOR SERIES LV The Illuminator Series LV is a 175VA-750VA fast transfer Emergency Lighting

More information

SWA-2441/2451 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL

SWA-2441/2451 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Instruction Manual SWA-2441/2451 PID TEMPERATURE CONTROLLER INSTRUCTION MANUAL Version 1.14 (August, 215) 1. Caution 3. Terminal Assignment Model SWA-2441 Model SWA-2451 This controller is intended to

More information

Copyright 2005 Kegel

Copyright 2005 Kegel Copyright 2005 Kegel 1 Cleaning 5 Cleaner Tank Filter - 154-0212B In-line Filter - 154-0255 Vacuum Motor - See Motors on Page 5 Following Items are Vacuum Housing - 153-0204H Fan Blade - 153-0204F Flexible

More information

Idle Free Systems, Inc. Reference Guide System Component Information

Idle Free Systems, Inc. Reference Guide System Component Information Idle Free Systems, Inc. Reference Guide System Component Information #68004 REV 3 #68004 REV 3 Idle Free Reference Sheets System Components & Trouble shooting Table of Contents RF # 101.0 102.0 103.0 104.0

More information

Product Name. Paraffin Dispenser. Operator s Manual. Histology Innovation for a NEW Generation PD-120; PD-220. A Division of General Data Healthcare

Product Name. Paraffin Dispenser. Operator s Manual. Histology Innovation for a NEW Generation PD-120; PD-220. A Division of General Data Healthcare A Division of General Data Healthcare Histology Innovation for a NEW Generation Pub No.: OM PD-1 June 2013, Version 1.8 PD-120; PD-220 Operator s Manual Product Name Here Catalog #s Paraffin Dispenser

More information

MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY

MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY MEASUREMENT SOLUTIONS FOR THE WATER & WASTEWATER INDUSTRY MUNICIPAL AND INDUSTRIAL WATER & WASTEWATER PROCESSING NOSHOK provides pressure, level and temperature measurement solutions, along with diaphragm

More information

Cyclic Corrosion Chamber C.C.T AUTO Series

Cyclic Corrosion Chamber C.C.T AUTO Series Cyclic Corrosion Chamber C.C.T AUTO Series CCT 5000 AUTO image merely illustrative Cooling system image merely illustrative Specifications/ Models CCT 1300 AUTO CCT 3000 AUTO CCT 5000 AUTO Allows 7 different

More information

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor Frozen pipes can be a costly problem. When pipes are exposed to subzero temperatures they can burst, leading to considerable damage and disruption. The Raychem frost protection system provides an efficient

More information

Cordless LED Lamps. Compatible with all standard leak detection dyes Powered by a rechargeable NiMH battery 120V, 230V, 240V or 100V smart AC charger

Cordless LED Lamps. Compatible with all standard leak detection dyes Powered by a rechargeable NiMH battery 120V, 230V, 240V or 100V smart AC charger Cordless LED Lamps TP-8690UV OPTIMAX 365 Cordless, Rechargeable UV Leak Detection Flashlight (Patent Pending) Makes Even Dirty Diesel Engine Oil Leaks Glow Brightly! State-of-the-art, ultra-high intensity

More information

Rotational Wand Mixer LevTech Disposable Mixing System

Rotational Wand Mixer LevTech Disposable Mixing System April 12, 2006 Rotational Wand Mixer LevTech Disposable Mixing System Contents Rotational Wand Mixing System (RWM): Overview, Specifications & Pictures RWM Disposable Mixing Bags: Description & Drawing

More information

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9.

SED2. Variable Frequency Drives. with Conventional Bypass Options. Variable Frequency Drives. Description. Features F-9. SED2 with Conventional Bypass Options Important Note: VD products are only available through authorized distribution channels. To locate an authorized distributor, please contact a Siemens Building Technologies

More information

Flow Limit Safety Shutoff Valves Model 1

Flow Limit Safety Shutoff Valves Model 1 Flow Limit Safety Shutoff Valves Model 1 Model 1 Series flow limit safety shutoff valves automatically shutoff all flow from the cylinder when flow exceeds a factory preset level. The Model 1 is normally

More information

Precision Regulators.

Precision Regulators. Precision www.numatics.com Table of Contents Features and Benefits 3 Electropneumatic Transducer 4-5 Economy Miniature Electropneumatic Transducer 6-7 Miniature Electropneumatic Transducer 8-9 Precision

More information

Cyclic Corrosion Test CORR Series

Cyclic Corrosion Test CORR Series Cyclic Corrosion Test CORR Series CCT 1300 CORR image merely illustrative Specifications/Model CCT 1300 CORR CCT 3000 CORR CCT 5000 CORR - Mode: SALT SPRAY / SALT FOG - Mode: WATER CONDENSATION HUMIDITY

More information

Thermo Scientific Hot Plates, Stirrers and Stirring Hot Plates

Thermo Scientific Hot Plates, Stirrers and Stirring Hot Plates Thermo Scientific Hot Plates, Stirrers and Stirring Hot Plates >> Performance, technology and safety Dependable Performance. Unmatched Safety. Exceptional Value. The success of your work demands precision

More information

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD)

BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD) LAKEWOOD INSTRUMENTS MODEL 260 SERIES BOILER BLOWDOWN CONDUCTIVITY CONTROLLER (CONTINUOUS METHOD) INSTALLATION & OPERATION MANUAL SERIAL #: Lakewood Instruments 7838 North Faulkner Road, Milwaukee, WI

More information

LAB EQUIPMENTS. Manufacturing & Servicing of:

LAB EQUIPMENTS. Manufacturing & Servicing of: Manufacturing & Servicing of: LAB EQUIPMENTS OVERHEAD STIRRER MAGNETIC STIRRER LAB OIL BATH LAB OIL BATH WITH MAG. STIRRER TEMPERATURE CONTROLLER MULTI CHANNEL TEMP. INDICATOR LAB CENTRIFUGE We Service

More information

Smart Series DSS-15-11, DSS-15-12, DSS DSA-15-11, DSA (AUSTRALIA)

Smart Series DSS-15-11, DSS-15-12, DSS DSA-15-11, DSA (AUSTRALIA) Smart Series DSS-15-11, DSS-15-12, DSS-30-12 DSA-15-11, DSA-15-12 (AUSTRALIA) Microprocessor-Based Temperature Control Module With Dual Digital Display User s Manual D-M-E Company ED-0123-OT-004-C D-M-E

More information

ProMinent Beta Solenoid Diaphragm Metering Pumps

ProMinent Beta Solenoid Diaphragm Metering Pumps Overview: Beta Ideal for basic chemical feed applications (see page 127 for spare parts, page 138 for accessory kits and page 138 for control cables) ProMinent pk_1_004_1 Capacity range 0.2-8.4 gph, 232-29

More information

Paraffin Dispenser Catalog # PD-120, PD-220 Operator s Manual Version 1.5b, Jan 2007

Paraffin Dispenser Catalog # PD-120, PD-220 Operator s Manual Version 1.5b, Jan 2007 Paraffin Dispenser Catalog # PD-120, PD-220 Operator s Manual Version 1.5b, Jan 2007 Be certain to read this manual thoroughly before proceeding with unpacking and installation. TABLE OF CONTENTS Topic

More information

¼ to 1HP Chiller Service Manual

¼ to 1HP Chiller Service Manual ¼ to 1HP Chiller Service Manual Before performing any service to the unit, reset the controller to its default settings. It is our experience that many problems can be resolved by doing so. See Sec. 3.1

More information

Table of Contents. Proportional & Precision Regulator Instrumentation

Table of Contents. Proportional & Precision Regulator Instrumentation Table of Contents Proportional & Precision Regulator Instrumentation...3-27 Features and Benefits... 3 Electropneumatic Transducer...4-5 Economy Miniature Electropneumatic Transducer...6-7 Miniature Electropneumatic

More information

HIGH INTENSITY DISCHARGE BALLASTS

HIGH INTENSITY DISCHARGE BALLASTS Philips Advance ballasts are available to operate the wide variety of metal halide, high pressure sodium and low pressure sodium lamps available in today s marketplace. Like fluorescent, lamps are gas

More information

ROTARY SCREW COMPRESSOR UNITS

ROTARY SCREW COMPRESSOR UNITS S70-200 SPL/MAY 2002 File: SERVICE MANUAL - Section 70 Replaces: S70-200/SPL MAY 2001 Dist: 3, 3a, 3b, 3c Service Parts List ROTARY SCREW COMPRESSOR UNITS WITH QUANTUM CONTROL MODELS: RWB II 60 through

More information

SERVICE MANUAL (DOMESTIC)

SERVICE MANUAL (DOMESTIC) SERVICE MANUAL (DOMESTIC) IMPINGER CONVEYOR OVENS IMPINGER II - ADVANTAGE SERIES Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States of America Phone : (800)

More information

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

A. Danfoss VLT Soft Starter The single speed drive.  For any soft start situation MAKING MODERN LIVING POSSIBLE MAKING MODERN LIVING POSSIBLE Danfoss VLT Soft Starter The single speed drive 3 1600 A For any soft start situation VLT Soft Starters cover the full range from simple start-stop operation to high end performance.

More information

Foaming of Lubricating Oils (manual)

Foaming of Lubricating Oils (manual) Foaming of Lubricating Oils (manual) ASTM D 892, ASTM D 6082 sequence IV, ISO 6247, DIN 51566, IP 146, JIS K2518, BS 5092 (obs.) Product group(s): User group(s): Scope: Lubricant Testing Automotive, Engine

More information

HEAT TREATMENT EQUIPMENT & ACCESSORIES

HEAT TREATMENT EQUIPMENT & ACCESSORIES HEAT TREATMENT EQUIPMENT & ACCESSORIES Dear Customer, ElectroHeat Sweden AB is an innovative company based in Gothenburg, Sweden, and has been operating since 1975. We manufacture industrial furnaces and

More information

ADU 5. Automatic Distillation Unit

ADU 5. Automatic Distillation Unit ADU 5 Automatic Distillation Unit Atmospheric Distillation Distillation tests are used to characterize the volatility of petrochemical products. These volatility characteristics are a critical measurement

More information

Skutt Electric Kilns. Skutt KS and KM Skutt KS and KM Skutt KS and KM Skutt Kilns

Skutt Electric Kilns. Skutt KS and KM Skutt KS and KM Skutt KS and KM Skutt Kilns Skutt Electric Kilns Skutt Kilns are known for their solid construction, energy efficient features, and reasonable pricing. They are available in a wide range of sizes and electrical configurations. Featured

More information

TECHNICAL DATA SHEET KVA UPS Systemss

TECHNICAL DATA SHEET KVA UPS Systemss Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800

More information

MODEL 422 Submersible Pump Controller

MODEL 422 Submersible Pump Controller MODEL 422 Submersible Pump Controller Monitors True Motor Power (volts x current x power factor) Detects Motor Overload or Underload Operates on 120 or 240VAC, Single-phase or 3-phase Built-in Trip and

More information

(770) Turning Parts Changers Into TROUBLESHOOTERS!

(770) Turning Parts Changers Into TROUBLESHOOTERS! Hydraulic Consulting, Inc. Turning Parts Changers Into TROUBLESHOOTERS! This e-book manual is your customized troubleshooting manual in Adobe Acrobat Portable Document File (PDF) format. It requires the

More information

SERVICE MANUAL (INTERNATIONAL)

SERVICE MANUAL (INTERNATIONAL) SERVICE MANUAL (INTERNATIONAL) IMPINGER CONVEYOR OVENS MODEL 1421-000-E, 1454, 1455 WITH PUSH BUTTON CONTROLS Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States

More information

Micro Dyne Motor Testing System

Micro Dyne Motor Testing System Data Sheet Motor Testing System Features designed specifically for miniature and micro s Torque: Easily convertible from 2.0 mn m to 4.0 mn m (0.28 oz in to 0.57 oz in) Speed: up to 100,000 rpm Power:

More information

BUY THE MINISTAR 20 CONTROL AND SAVE ONLY 1 OF OUR 19 OFFERS OF OUR IKA SPECIALS. Our specials, 1st edition 2018.

BUY THE MINISTAR 20 CONTROL AND SAVE ONLY 1 OF OUR 19 OFFERS OF OUR IKA SPECIALS. Our specials, 1st edition 2018. EN BUY THE MINISTAR 20 CONTROL AND SAVE 250.00 ONLY 1 OF OUR 19 OFFERS OF OUR IKA SPECIALS Our specials, 1st edition 2018. SPECIALS /// 1st edition 2018 Welcoming 2018 with new and attractive offers. In

More information

Heating Cable. Description

Heating Cable. Description ITLS Base Panel Heat Tracing Control Panel for Ordinary Areas 10 VGA Touch Screen HMI 40 Amps/Loop @ 100 600 VAC 6 Loops to 72 Loops NEMA 4 or NEMA 4X Enclosure SCR Control Optional Wireless Temperature

More information

Instruction Manual For Thermistor Vacuum Gauge GT-430

Instruction Manual For Thermistor Vacuum Gauge GT-430 1155 Myers Lane Kittanning, PA 16201 Phone: 724-545-8331 Fax: 724-545-8332 www.myers-vacuum.com For Thermistor Vacuum Gauge TABLE OF CONTENTS SECTION DESCRIPTION 1.0 INTRODUCTION 1.1 Product Description

More information

Exercise 3-1. Basic Hydraulic Circuit EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Complete hydraulic circuit

Exercise 3-1. Basic Hydraulic Circuit EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Complete hydraulic circuit Exercise 3-1 Basic Hydraulic Circuit EXERCISE OBJECTIVE When you have completed this exercise, you will be familiar with the hydraulic schematic and components of the nacelle trainer. You will identify

More information

700 KVA / 550 KW POWERED by

700 KVA / 550 KW POWERED by 700 KVA / 550 KW POWERED by MODEL Triton Power is a world leader in the design, manufacture of stationary, mobile and rental generator sets and Power Modules from 10 to 2000 kw. Through our commitment

More information

Signet Conductivity/Resistivity Electrodes

Signet Conductivity/Resistivity Electrodes Signet 2818-2823 Conductivity/Resistivity Electrodes 2818 2819 2820 2821 2822 2823 Sanitary Features Standard process connections - Polypro - SS on 10 and 20 cell - Tri-clamp 1-1½ in., 2 in. - Opt. ½ in.

More information

Environmental Chamber

Environmental Chamber Environmental Chamber JTH Series Welltech quality construction includes: both stainless steel exterior and interior, thermal-breaks and hinged panels. For refrigeration we are using reliable compressors

More information

Synchronous motor with fluid coupling drive arrangement for a preheater ID Fan. presenter Nathan Schachter CIMENTEC Engineering Ltd

Synchronous motor with fluid coupling drive arrangement for a preheater ID Fan. presenter Nathan Schachter CIMENTEC Engineering Ltd Synchronous motor with fluid coupling drive arrangement for a preheater ID Fan presenter Nathan Schachter SLC PLC Lubrication units Cooling Water DCS SUB BD Breaker SR469 GE STAT-XTOR PLC Field Application

More information

PowerCommand 2100 digital generator set control

PowerCommand 2100 digital generator set control Specification sheet PowerCommand 2100 digital generator set control Description The PowerCommand 2100 control is a microprocessor-based generator set monitoring, metering and control system. The control

More information

Weksler Accessories STATIONARY RED SET HAND OVERLOAD STOP SPECIAL DIAL MAXIMUM POINTER VACUUM STOP

Weksler Accessories STATIONARY RED SET HAND OVERLOAD STOP SPECIAL DIAL MAXIMUM POINTER VACUUM STOP 33 Weksler Accessories THROTTLING DEVICES A throttling device should be used when a pressure gauge is subjected to rapid pressure fluctuations, which make the gauge difficult to read because of rapid pointer

More information

System 350 S350P Proportional Plus Integral Temperature Stage Module

System 350 S350P Proportional Plus Integral Temperature Stage Module FANs 930, 930.5 Add-On Modules Section Product/Technical Bulletin S350P Issue Date 0997 System 350 S350P Proportional Plus Integral Temperature Stage Module The S350P is used in conjunction with the A350

More information

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual

INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual INOVA HIGHTECH Ltd. MEP 002/003 Auto Starter Manual Complete Installation and Operating Manual for the MEP 002/003 Auto / Remote Starter for the following MEP Power Generators: MEP 002A/003A/011A/802A/803A/811A

More information