1 Accurate to 0.1 NIST Traceable Advanced PID Algorithm USB Port Free datalogging/control software CONTROLLERS Serving the laboratory glassware industry for over 75 years
2 State-of-the-Art and Vacuum Controllers Ace Glass now offers the most advanced laboratory temperature controllers for virtually every application in your lab. From a simple temperature monitor to a full research-grade Quad unit with four fully independent channels, ACE can provide the answer and the best value for your application. Units are available in four different thermocouple types and temperature ranges. Controllers may be purchased with or without thermocouples, and the probe receptacles on each unit are color coded to match the thermocouple types they accept: blue = T ; yellow = K ; Black = J ; and white = RTD. All controllers have free control software that provides 0.1º C regulation of any lab device or piece of equipment. Included in this brochure is a portion of our wide offering of thermocouple probes, and our latest models for vacuum and pressure control, which feature free control software that can also provide data-logging capabilities. 230V versions are CE marked. Economy Controllers Ultra Compact, Ace Economy Controller with J, T, or K thermocouple inputs; output power 120 volt/60 Hz, 15 amp maximum. Bench or bar mountable. 120 volt/60 Hz input. Single-loop time proportional output: 10 seconds cycle rate. Solid state relay control contact. Accuracy over range: 0.25% (max 2 C). Set-point control accuracy: ± 0.1 C. Microprocessor-based 1/32 DIN module, dual process and set-point value display. Auto tuned PID with fuzzy logic. Programmable: ramp and soak (16 segment). Size: 2"x 5¼"x 5¼" (HxWxD); 120vac, 15 amps, Weight: 2 lbs, 2 oz. No 0 to 800 J No 200 to 250 T No 50 to 1200 K Model 150, J-Kem An ideal controller for applications that don t require the precise regulation of 200 Series controllers. This compact unit features 1200 watts of power, sufficient for heating 5 L mantles, many ovens, and other devices. Ramp-to-Set Point feature standard. USB port and data logging and control software optional. 2.5" x 3.75" x 5.25" (HxWxD) / 120vac, 10 amps, 1200 watts 150-T No 200 to 250 T J No 0 to 800 J K No 50 to 1200 K T-S Yes 200 to 250 T J-S Yes 0 to 800 J K-S Yes 50 to 1200 K Model 150/Timer, J-Kem Same power and versatility as the Model 150, but with a 100-hour digital timer to turn heating ON or OFF at a user-specified time. 2.5" x 4.75" x 5.5" (HxWxD) / 120vac, 10 amps, 1200 watts 150/Timer-T No 200 to 250 T /Timer-J No 0 to 800 J /Timer-K No 50 to 1200 K /Timer-T-S Yes 200 to 250 T /Timer-J-S Yes 0 to 800 J /Timer-K-S Yes 50 to 1200 K
3 Single-Channel Controllers Model 210, J-Kem The Model 210 is our most compact research grade controller, yet packed with 1200 watts of power. Sufficient for heating mantles up to 5 L in size, and most laboratory ovens, hot plates, reaction blocks and other heaters. Comes complete with USB port and data logging and control software. Power control computer provides 0.1 C regulation of anything. 3.25" x 5.25" x 7.25" (HxWxD) / 10 amps, 1200 watts. 210-T No 200 to 250 T J No 0 to 800 J K No 50 to 1200 K T-S Yes 200 to 250 T J-S Yes 0 to 800 J K-S Yes 50 to 1200 K Model 310, J-Kem 230V, CE-marked version of Model 210, above. w/ Sensor Cord 310-T-S Yes 200 to 250 T J-S Yes 0 to 800 J K-S Yes 50 to 1200 K Model 210/Timer, J-Kem Same power and versatility as the Model 210, above, but also contains a 100-hour digital timer to turn heating OFF or ON at a user-specified time. A new safety feature automatically disconnects power from the heater following recovery from a power failure. Comes complete with USB port and data logging and control software. Power control computer provides 0.1 C regulation of anything. 3.5" x 6.75" x 6" (HxWxD) / 120vac, 10 amps, 1200 watts. 210/Timer-T No 200 to 250 T /Timer-J No 0 to 800 J /Timer-K No 50 to 1200 K /Timer-T-S Yes 200 to 250 T /Timer-J-S Yes 0 to 800 J /Timer-K-S Yes 50 to 1200 K Model 250, J-Kem The Model 250 has both heating and cooling outlets for maximum versatility. Two heating outlets supply 1800 watts of power for large equipment and heating mantles up to 22 L. The third outlet, also 1800 watts and normally used for cooling, is programmable to provide power above, below, or at the set point. Comes complete with USB port and data logging and control software. Power control computer provides 0.1 C regulation of anything. 3.5" x 7.75" x 9.25" (HxWxD) / 120vac, 15 amps, 1800 watts. 250-T No 200 to 250 T J No 0 to 800 J K No 50 to 1200 K T-S Yes 200 to 250 T J-S Yes 0 to 800 J K-S Yes 50 to 1200 K
4 12318 Model 260/Timer, J-Kem The Model 260/Timer disconnects output power if the process temp exceeds the setpoint by a user specified amount or following a recovery from a power failure. Overtemp is signaled by both a lamp an an audible alarm. Features a 100 hour timer, two power outlets and 0.1º C regulation of anything. NIST traceable, USB port and free data logging and control software. 3.5" x 7.75" x 9.25" (HxWxD) / 15 amps, 1800 watts. VAC 260/Timer-J 120 No 0 to 800 J /Timer-K 120 No 50 to 1200 K /Timer-T 120 No 200 to 250 T /Timer-J-S 120 Yes 0 to 800 J /Timer-K-S 120 Yes 50 to 1200 K /Timer-T-S 120 Yes 200 to 250 T Model 360/Timer, J-Kem 230V, CE-marked version of Model 260/Timer, above. 360/Timer-J-S Yes 0 to 800 J /Timer-K-S Yes 50 to 1200 K /Timer-T-S Yes 200 to 250 T High Safety Controller Model 270, J-Kem Designed for processes requiring uncompromising safety. The only temperature controller available with a built-in, independent backup controller to guard against heating accidents resulting from equipment failure. The desired temperature is entered into the main temperature controller, which regulates heating, and then a high-temperature cut-off is entered into the backup limit controller. If the reaction reaches the high-temperature limit, or if a thermocouple should break, power is turned off to the heater until the controller is manually reset. Both meters independently monitor the reaction temperature. In the event that one meter fails, the other takes over to prevent a heating accident. Provides 100% redundant control. 3.75" x 7.75" x 9.25" (HxWxD) / 120vac, 15 amps, 1800 watts total watts maximum per channel. 270-T No 200 to 250 T J No 0 to 800 J K No 50 to 1200 K T-S Two of each 200 to 250 T J-S Two of each 0 to 800 J K-S Two of each 50 to 1200 K The Model 270 Series units noted above each come with two thermocouple sensors, two cords and two adapters. 4
5 Multi-Channel Controllers Gemini Series, J-Kem The Gemini Series features two temperature controllers in a single cabinet to regulate two independent reactions. This versatile controller has high-power outlets and a 100-hour digital timer (on channel one) to turn heating on or off at a user-entered time. Features include: over-temperature protection circuit with audible alarms; dual temperature displays; selectable operating modes; twin circuit breakers; and 100% solid-state design. 3.75" x 7.75" x 9.25" (HxWxD) / 120vac, 15 amps, 1800 watts total watts maximum per channel. Gemini-T No 200 to 250 T Gemini-J No 0 to 800 J Gemini-K No 50 to 1200 K Gemini-T-S Two of each 200 to 250 T Gemini-J-S Two of each 0 to 800 J Gemini-K-S Two of each 50 to 1200 K Gemini Series, J-Kem 230V, CE-marked version of Gemini Series, above. Gemini-T-S-230 Yes 200 to 250 T Gemini-J-S-230 Yes 0 to 800 J Gemini-K-S-230 Yes 50 to 1200 K Apollo Series, J-Kem Has all the features of the Gemini series, above, but also features an independent 100-hour digital timer on each controller channel. 4" x 8" x 9" (HxWxD) / 120vac, 15 amps, 1800 watts total watts maximum per channel. Apollo-T No 200 to 250 T Apollo-J No 0 to 800 J Apollo-K No 50 to 1200 K Apollo-T-S Two of each 200 to 250 T Apollo-J-S Two of each 0 to 800 J Apollo-K-S Two of each 50 to 1200 K The Apollo and Gemini Series units noted above each come with two thermocouple sensors, two cords and two adapters Quad Series, J-Kem The Quad is your solution when bench space is at a premium the Quad packs four independent temperature controllers into a single unit! Each of the four controller channels has 1200 watts of power, an independent display, and an over-temperature protection circuit. 5.25" x 7" x 7.5" (HxWxD) / 120vac, 15 amps, 1800 watts total watts maximum per channel. Quad-T No 200 to 250 T Quad-J No 0 to 800 J Quad-K No 50 to 1200 K Quad-T-S Four of each 200 to 250 T Quad-J-S Four of each 0 to 800 J Quad-K-S Four of each 50 to 1200 K The Quad Series units noted above each come with four thermocouple sensors, four cords and four adapters. 5
6 High Power Controller Model HCC, J-Kem The HCC line of controllers are designed to power large-scale equipment with volumes up to 100 liters. Built with the same commitment to safety as our controller, the HCC Series features a built-in, independent backup controller to guard against heating accidents resulting from equipment failure. The desired temperature is entered into the main temperature controller, which regulates heating, and then a high-temperature cut-off is entered into the backup limit controller. If the reaction reaches the high-temperature limit, or if a thermocouple should break, power is turned off to the heater until the controller is manually reset. Both meters independently monitor the reaction temperature. In the event that one meter fails, the other takes over to prevent a heating accident. Provides 100% redundant control. These highpower controllers also incorporate a 100-hour timer to turn heating ON or OFF at a user-specified time. Comes complete with USB port and data logging and control software. Power control computer provides 0.1 C regulation of anything. Requires sensor (not included) for operation. 230V version available via special order. 5.5" x 12" x 12.5" (HxWxD) / 130 amps, 3600 watts Instatherm Controller VAC HCC-130-T No 200 to 250 T HCC-130-J No 0 to 800 J HCC-130-K No 50 to 1200 K Model 410, J-Kem The Model 410 is designed for heaters that cannot be operated at 120VAC. This makes the unit perfect for use with many of our Ace Instatherm oil baths. Maximum output voltage of the Model 410 is selected using the power output knob on the front of the controller. Selectable output voltage limit provides precise power and temperature control while protecting low voltage heaters. Comes complete with USB port and data logging and control software. Power control computer provides 0.1 C regulation of anything. 3.25" x 5.25" x 7.25" (HxWxD) / 10, 20, 40, 60, 120 vac, 10 amps, 1200 watts 410-T No 200 to 250 T J No 0 to 800 J K No 50 to 1200 K T-S Yes 200 to 250 T J-S Yes 0 to 800 J K-S Yes 50 to 1200 K Instatherm Bath Kit 9601 Instatherm Bath Kit, Ace/J-Kem Consists of one each and bath, plus one Digital Controller with one J Sensor and controller cord. 120V
7 / Sensors For J-Kem Controllers T- Sensors T thermocouple temperature sensors for use with all J-Kem T model temperature controllers. Either 1/4- or 1/8-inch O.D. Available in 304 stainless steel or PTFE coated stainless steel sheaths of various lengths. O.D. PTFE Coated? 1/8 6 No /8 12 No /8 18 No /8 24 No /8 36 No /8 6 Yes /8 12 Yes /8 18 Yes /8 24 Yes /8 36 Yes /4 6 No /4 12 No /4 18 No /4 24 No /4 36 No /4 6 Yes /4 12 Yes /4 18 Yes /4 24 Yes /4 36 Yes J- Sensors J thermocouple temperature sensors for use with all J-Kem J model temperature controllers. Either 1/4- or 1/8-inch O.D. Available in 304 stainless steel or PTFE coated stainless steel sheaths of various lengths. O.D. PTFE Coated? 1/8 6 No /8 12 No /8 18 No /8 24 No /8 6 Yes /8 12 Yes /8 18 Yes /8 24 Yes /8 36 Yes /4 6 No /4 12 No /4 18 No /4 24 No /4 36 No /4 6 Yes /4 12 Yes /4 18 Yes /4 24 Yes /4 36 Yes K- Sensors K thermocouple temperature sensors for use with all J-Kem K model temperature controllers. Either 1/4- or 1/8-inch O.D. Available in 304 stainless steel or PTFE coated stainless steel sheaths of various lengths. O.D. PTFE Coated? 1/8 6 No /8 12 No /8 18 No /8 24 No /8 36 No /8 6 Yes /8 12 Yes /8 18 Yes /8 24 Yes /8 36 Yes /4 6 No /4 12 No /4 18 No /4 24 No /4 36 No /4 6 Yes /4 12 Yes /4 18 Yes /4 24 Yes /4 36 Yes For extension cords, see Ace straight and coiled cords, on the following page. 7
8 Sensor extension cords for use with all J-Kem thermocouple probes. Cords match color of probe type, blue, black, yellow or white. Available in either 10- or 20-foot coiled or straight styles. Select length, type, and connector, SMP (flat plug) or OST (round plug). OST (Standard) SMP (Mini) Sensor Cords Coiled Probe Style (ft.) Connector J 10 SMP K 10 SMP T 10 SMP RTD 10 SMP J 10 OST K 10 OST T 10 OST J 20 SMP K 20 SMP T 20 SMP J 20 OST K 20 OST T 20 OST Dual Sensor Cords Dual element extension cords for use with dual element sensors for J-Kem models HCC and 270 temperature controllers. Available in T, K, and J types in 10- or 25-ft. lengths. Probe Style (ft.) T J K T J K Sensor Cords Straight Probe Style (ft.) Connector J 10 SMP K 10 SMP T 10 SMP J 10 OST K 10 OST T 10 OST RTD 10 OST J 20 SMP K 20 SMP T 20 SMP J 20 OST K 20 OST T 20 OST Dual Sensors PTFE Coated Dual coupling temperature thermocouple sensors for use with Model HCC and 270 J-Kem temperature controllers. Available in J, T or K types. Probes are PTFE coated stainless steel in various lengths and O.D. Probes require extension cords. O.D. Sensor 1/8 12 T /4 12 T /4 24 T /4 36 T /8 12 J /4 12 J /4 24 J /4 36 J /8 12 K /4 12 K /4 24 K /4 36 K
9 12185 Wire Sensors Flexible 30-gauge thin wire thermocouple. Ideal for small volumes and hard-to-reach spots. Can be used with heating mantles, hotplates, inside of heating equipment and for small surface measurement. Can be inserted through rubber septum for an airtight seal. Available in standard connections, and in 36- and 72-inch lengths. PTFE Coated? Sensor Yes 36 T Yes 36 K No 72 T No 72 K No 72 J Monitor Needle-Tip Sensors Needle-tip, 17-gauge thermocouple sensor for measurement and control of very small volumes and in small systems. Sensors come coated and uncoated in 3.5- or 7-in. lengths. Actual temperature measure is at first 2mm of the probe and must have liquid contact for accurate readings. May be inserted through rubber septa 9107 or 9106 for air-tight seal. Comes with 72-in. PTFE wire extension. Available in T, K, or J type connections. PTFE Coated? Sensor Yes 3.5 T Yes 7.0 T Yes 3.5 K Yes 7.0 K Yes 3.5 J Yes 7.0 J No 3.5 T No 7.0 T No 3.5 K No 7.0 K No 3.5 J No 7.0 J Digital Monitor Monitors and displays the temperature of an attached piece of equipment on a bright LED display. Built-in USB port and free data logging software allows remote temperature monitoring, and provides a GMP, GLP compliant temperature history. is not included. 2.5" x 4.75" x 5.5" (HxWxD) / 50 watts, USB 2.0. DM120-T 200 to 250 T DM120-J 0 to 800 J DM120-K 50 to 1200 K Digital Monitor 230V, CE-marked version of Digital Monitor, above. DM230-T 200 to 250 T DM230-J 0 to 800 J DM230-K 50 to 1200 K
10 Vacuum Regulators Precision Vacuum Regulator, J-Kem Perfect for vacuum distillation, unit automatically compensates for leaks in the equipment under test and maintains precise pressure, even in systems with a continuous gas purge. This computer (built-in) controlled vacuum regulator maintains pressure in the range of 0.1 to 760 Torr (atm pressure) in test instruments with volumes as small as 1 ml. Standard features include 16-step programmable pressure ramp and serial communications for PC control and data logging. DVR Specifications: Transducer Diaphragm: Stainless Steel Accuracy: 0.1% Proof Pressure: 200% Controller Regulation: Resolution: Vapor Path Materials: Ramp Rates: Serial Communications: 0.015% of range 0.1 Torr of 0.01 psi Stainless steel and PTFE 100 Torr/sec to 0.1 Torr/hr. RS232 (RS485 or USB on request) Stainless Steel Proportioning Valves Select one for use with Digital Vacuum Regulator , above. For Reactor Volumes Cv Orifice Size PSV-2 1 ml to 2 L in PSV-3 25 ml to 4 L in PSV ml to 22 L in PSV-5 1 L to 50 L in PSV-6 Large Capacity in PSV-7 Large Capacity in PSV-8 Large Capacity in PSV-9 Large Capacity in DVR-PNV Stainless Steel Needle Valve, improves regulation
11 Connect to any vacuum pump or vacuum source, and then to any piece of equipment, to regulate pressure, in most cases to ±1 Torr. A standard pressure ramp feature evacuates equipment at a user-defined rate to eliminate bumping due to solvent degassing or over-evacuation. Ideally suited for large volume distillations, rotary evporators and vacuum chambers. Not recommended for small volume distillations or applications which involve a continuous purge with gas Vacuum Regulator No Mercury Designed for vacuum systems that run continuously, such as oil-filled vacuum pumps, aspirators, or with systems that are always on, like in-house vacuum systems. The unit regulates pressure by opening and closing a valve that separates the vacuum source from the system being evacuated. DVR Vacuum Regulator No Mercury 230V, CE-marked version of DVR-200 Vacuum Regulator, above. DVR Vacuum Regulator No Mercury Designed for use with diaphragm vacuum pumps. In some systems, pressure is regulated by turning the vacuum pump itself on and off. This unit extends the life of diaphragm pumps by never forcing the pump to start against an established vacuum, which can increase pump life by 100%. DVR Vacuum Regulator No Mercury 230V, CE-marked version of DVR-280 Vacuum Regulator, above. DVR Digital Vacuum Monitor Continuous, no regulation, Not pictured. DVM Digital Vacuum Monitor 230V, CE-marked version of DVM-100 Digital Vacuum Monitor, above. Recovers >99% of solvent from rotary evaporators Solvent DVR Pressure (mm Hg) Solvent Volume Time To Dryness Percent Recovery Ether 475 Torr 340 ml 14.6 min. 99.6% CH 2 CI Torr 360 ml 21.9 min. 99.8% CH 2 CI Torr 255 ml 5.9 min. 99.5% EtOAc 90 Torr 316 ml 17.0 min. 99.9% Toluene 50 Torr 273 ml 15.7 Min. 99.4% DVM V versions are CE marked 11
12 Water Flow Monitors/Controllers Model LS-120 Lab Safety Controller, J-Kem Lab safety controller by J-Kem combines all the features of the Digital Monitor and the Water-Flow Monitor into a single versatile instrument. Plug any piece of equipment into the monitor, then if the water flow rate falls below the set level, or if the reaction temperature goes above or below the user set limits, the outlet power turns off automatically. The unit will also cut off power if the main power is interrupted. The controller then has to be reset. See Ace product family for flow sensors. With Sensor Cord LS-120-T No 200 to 250 T LS-120-J No 0 to 800 J LS-120-K No 50 to 1200 K Description Flow Rate, LPM WFM-01 Flow Sensor 0.1 to WFM-02 Flow Sensor 1 to WFM-03 Flow Sensor 2 to Shut-Off Valve Model WFM-120 Water Flow Monitor, J-Kem J-Kem monitor precisely measures the flow of water through a condenser, bath or a photochemical reactor. Upon interruption or if the flow drops below an operator set rate, power to the monitored equipment is cutoff. Manual power reset. Inclusion of a shut-off valve and either a audible alarm or a digital alarm is recommended. Description Flow Rate, LPM WFM-01 Flow Sensor 0.1 to WFM-02 Flow Sensor 1 to WFM-03 Flow Sensor 2 to Shut-Off Valve WFM-120 Water Flow Monitor Alarm, J-Kem Digital alarm outlet and audible alarm accessories for J-Kem safety controller and water-flow monitors. Allows and units to be set up for alarm warnings when in unsafe conditions. The audible alarm sounds during low or no water conditions for the monitor and the digital alarm activates on either the water flow monitor or the safety controller when conditions are out of set ranges. For Controllers Alarm WFM-AA & Digital WFM-OC Audible CONTROLLERS P.O. Box 688 Vineland, NJ Fax: TOLL-FREE: FAX: sales@aceglass.com
Accurate to 0.1 NIST Traceable Advanced PID Algorighm USB Port Free datalogging/control software. Controllers I N S C O N TA G N
Accurate to 0.1 NIST Traceable Advanced PID Algorighm USB Port Free datalogging/control software Controllers P 2010 C O N TA R I C I I N S G N Serving the laboratory glassware industry for over 70 years
More informationInstatherm ACE. The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and heating mantles P.
ACE For Glass Vessels Borosilicate Glass Fused-to-Glass Conductive Heating Film Integral Outer Insulation Instatherm The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and
More informationThe Safest Heating Method!
ACE Instatherm For Glass Vessels The Safest Heating Method! Borosilicate Glass Eliminate the need for heating tapes, immersion heaters and heating mantles. Instatherm is a safer, more precise heating method
More informationInstatherm ACE. The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and heating mantles.
ACE For Glass Vessels Borosilicate Glass Fused-to-Glass Conductive Heating Film Integral Outer Insulation Instatherm The Safest Heating Method! Eliminate the need for heating tapes, immersion heaters and
More informationTHERMAL CONTROL SYSTEM OPERATION AND MAINTENANCE MANUAL
Macintyre Electronic Design Associates Inc. 43676 Trade Center Place, Suite 145, Dulles, VA 20166 Phone: (703) 996-8990 FAX: (703) 996-8770 e-mail: sales@meda.com THERMAL CONTROL SYSTEM OPERATION AND MAINTENANCE
More informationParr Instrument Company
No. 446M Parr Instrument Company Operating Instruction Manual for 4836 Temperature Controllers TABLE OF CONTENTS Related Instructions...2 Customer Service...2 Preface...3 Scope...3 Applications...3 Electrical
More informationTime Electronics. Calibration, Test and Measurement. Portable Process and Pressure Calibration Instruments
Time Electronics Calibration, Test and Measurement Portable Process and Pressure Calibration Instruments Calibrators Simulators Sources Pumps Gauges www.timeelectronics.com Loop & Temperature Calibration
More informationProduct Information. Kugelrohr Short-Path Distillation Apparatus. Operation Instructions Z V Apparatus Z V Apparatus
Product Information Kugelrohr Short-Path Distillation Apparatus Operation Instructions Z401137 115V Apparatus Z401145 230V Apparatus Table of Contents Safety Information Intended Use 3 General Usage 3
More informationVacuum Gauge Catalog
2019 Vacuum Gauge Catalog Possibly The World s Best Gauge Tubes! 1/8 in. NPT Standard Internal Volume Only 0.78 cc Working Pressure to 300 PSI (Tested to 1200 PSI) NO PLASTIC! Pirani Gauges 1 to 2000 mtorr.01
More informationRecirculating Coolers
SELECTION GUIDE (General Models) (Low Temp. Models) (Advanced Low Temp. Models) (High Temp. Models) General Models Low Temp. Models Advanced Low Temp. Models High Temp. Models HX-20 Working Cooling Temp.
More informationE v a p o r a t o r s
E v a p o r a t o r s Ni Evaporator 11 to 96 Needles These systems have has a flow meter attached to the side for controlling the gas flow to the equalizer manifold giving equal gas flow to each well.
More informationVarian, Inc. Vacuum Technologies. TPS Turbo Pumping Systems. Features and Benefits 2-3. Mini-TASK AG TPS-compact 6-7
Varian, Inc. Vacuum Technologies TPS Turbo Pumping Systems Features and Benefits 2-3 Mini-TASK AG81 4-5 TPS-compact 6-7 TPS-mobile and TPS-bench 8-10 TPS Turbo Pumping Systems Features and Benefits The
More informationAMI. American Magnetics, Inc. Excellence in Magnetics and Cryogenics
Cryogenic Liquid Level Instruments Versatile Reliable Affordable AMI American Magnetics, Inc. Excellence in Magnetics and Cryogenics A Versatile Level Measurement System... A Variety of Liquids Nitrogen
More informationFN Series Scalable N+1 UPS 3kVA to 24kVA Rackmount
FN Series Scalable N+ UPS kva to kva Rackmount Advanced Features: * Parallel Rackmount Units with a Single of up to kva * True N+ Redundancy * ECO Mode: 97% Efficiency * DSP Double-Conversion On-line Sinewave
More information1291BL Series Technical Specification Single Axis Position and Rate Table System
Datasheet 1291BL Series Technical Specification Single Axis Position and Rate Table System DESCRIPTION The Model 1291BL Single Axis Position and Rate Table System is designed to provide precise position,
More informationMixer/Temperature Control
Mixer/Temperature Control Dry Bath, Incubator, Shaker, Stirring Water Bath Major Science designs and manufactures a comprehensive range of mixing and temperature control equipments for use in the fields
More information4, 6, 8 & 11 Su p e r Ev a c Vacuum Pumps
SuperEva c Vacuum Pump Systems hose adapters, valves and Parts vacuum and hoses Recovery YELLOW JACKET 4, 6, 8 & 11 Su p e r Ev a c Vacuum Pumps Pulls a deep vacuum of 15 microns or better, protecting
More informationStirred Reactors and Pressure Vessels
P a r r I n s t r u m e n t C o m p a n y Stirred Reactors and Pressure Vessels Designing and Building Quality Pressure Apparatus for Over 100 Years Bulletin 4500 Volume 14 Start Chapter Eight This pdf
More informationLiquid Chillers. Options Available Heating RS-232 interface RS-485 interface Computer Communications software Ramping and soaking
Liquid Chillers 730-2700 BTU/hr Teca Liquid Chillers are compact and reliable alternatives to conventional recirculating coolers. A complete integrated package is now offered in a standard configuration.
More informationPETRODIST PILODIST. Crude oil distillation systems according to ASTM - standards for fractionation and boiling analysis
With kind permission of BP Gelsenkirchen GmbH PETRODIST Crude oil distillation systems according to ASTM - standards for fractionation and boiling analysis Version 9/ January 2012 1 PETRODIST is a brand
More informationorb effortless reactions Unrivalled quality» Intuitive design» Exceptional value
orb effortless reactions www.syrris.com Unrivalled quality» Intuitive design» Exceptional value efforless reactions Benefits Quick vessel changes: The unique vessel clamp mechanism allows quick and easy
More information1291BL Series Technical Specification Single-Axis Rate and Positioning Table System
Datasheet 1291BL Series Technical Specification Single-Axis Rate and Positioning Table System DESCRIPTION The Model 1291BL Single Axis Positioning and Rate Table System is designed to provide precise position,
More informationGLASSCO LABORATORY EQUIPMENTS PVT. LTD.
PROGRAMMED FOR PRECISIO N GLASSCO LABORATORY EQUIPMENTS PVT. LTD. STAINLESS STEEL TOP Magnetic Stirrer with Hotplate - Analog Aluminium Moulded Construction Easy temperature & Stir controls Installed with
More information7526A Precision Process Calibrator. Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument
7526A Precision Process Calibrator Calibrate temperature, pressure, and low dc voltage process tools in a single benchtop instrument The 7526A Precision Process Calibrator calibrates a wide range of pressure
More informationIncubators. Incubators
Incubators Stuart has a number of incubators specially designed for accurate and reproducible temperature controlled applications. All incubators have state of the art microprocessor detection, setting
More informationLow Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications
FCI ST50 Series Flow Meters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications FCI ST50 FLOW METER Wastewater Treatment Aeration Control Blower
More informationZINSSER-MINILAB A Complete Laboratory in a Case
ZINSSER-MINILAB A Complete Laboratory in a Case The Zinsser-Minilab has been used in many European schools since the late 80s, but has also become a useful tool for the development and testing of new strategies
More informationPATROL UPLC Process Analysis System for Production
PATROL UPLC Process Analysis System for Production The PATROL UPLC Process Analysis System for Production is an integrated system solution designed and engineered to perform online and atline reaction
More information500/800. CalTrak. High Accuracy Modular Primary Standard Gas Flow Calibrator Cal Labs & Industry. FEATURES DESCRIPTION
High Accuracy Modular Primary Standard Gas Flow Calibrator Cal Labs & Industry FEATURES Primary standard, dimensionally based piston prover system Accuracy: CalTrak 500: up to +/- 0.35% of reading mass
More informationPOWER. Switch opening. Enter/Exit Menu Menu Scroll Increase/Decrease Setpoint GCE SERIES MODEL 10AFE MODEL 20AFE
CMW MANU STOP TUNE Quincy Lab, Inc. Model AFE Digital Series Lab Ovens With Microprocessor Control & Digital Display OPERATING MANUAL Standard Contents (1) AFE Series Lab Oven (2) Adjustable chrome wire
More informationAUTOMATIC 12 WAY HEAT TREATMENT CONSOLE
Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL
More informationB BASIC HEAT TREATMENT CONSOLE
Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL
More informationCooled incubators (ST), laboratory refrigerators
Cooled incubators (), laboratory refrigerators The version has been designed for those customers who look for professional lab equipment at a very competitive price. The cooled incubators () and refrigerators
More informationACE GLASS. Benchtop Reactors. Filter Reactors Pressure Reactors
ACE GLASS Benchtop Reactors Filter Reactors Pressure Reactors 2 Table of Contents Item Page Filter Reactors... 3 Benchtop All-in-One Reactor... 12 Pressure Reactors... 13 Reactor Accessories... 9,20 Temperature
More informationInstallation Instructions for: Channel Thermocouple Amplifier
Installation Instructions for: 30-2204 4 Channel Thermocouple Amplifier WARNING: This installation is not fo r the electrically or mechanically challenged! Use this sensor with EXTREME caution! If you
More informationLevel and Flow Measurement. Sludge Finder 2
Level and Flow Measurement Sludge Finder 2 Sludge Finder 2 Sludge Finder 2 Is a proven effective sludge blanket interface monitor in both waste water and industrial applications. Sludge Finder 2 provides
More information6. Document tasks performed during visit and report any observations to the appropriate
Chiller Annual Maintenance RFP Attachment B Services Required Tasking: Vibration Analysis 1. All work shall be performed in accordance with safety policies 2. Check with appropriate customer representative
More informationSSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview
Product Description The MediaGauge MG-MD is a multi-functional digital pressure gauge consisting of a media isolated piezoresistive pressure sensing element, signal conditioning circuitry for temperature
More informationMyers Vacuum 1155 Myers Lane Kittanning, PA Phone: Fax: Instruction Manual For Thermocouple Vacuum Gauge GTC-390
1155 Myers Lane Kittanning, PA 16201 Phone: 724-545-8331 Fax: 724-545-8332 For Thermocouple Vacuum Gauge TABLE OF CONTENTS SECTION DESCRIPTION 1.0 INTRODUCTION 1.1 Product Description 1.2 Operating Principles
More informationInterface I-300 / I-300 Pro Technical data sheet
Interface I-300 / I-300 Pro Technical data sheet The Interface I-300 or I-300 Pro are the central control unit for all process parameters of a Rotavapor R-300 system: rotation speed, temperature (heating
More informationSGO Series. SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 SGO5
SGO Series SHEL LAB Gravity Convection Laboratory Ovens SGO1 SGO3 Ideal for Industrial, Analytical, and General Laboratory Applications SHEL LAB Gravity Convention Laboratory Ovens are recommended for
More informationModel 30GCE Low-Temp Oven POWER. Switch opening. View Setpoint Increase Setpoint Decrease Setpoint (3 sec.) Enter/Exit Menu Levels GCE SERIES
Model AFE - LT Low-Temp Series Ovens With Microprocessor Control & Digital Display OPERATING MANUAL Standard Contents (1) AFE Series Low-Temp Oven (2) Adjustable chrome wire shelf (4) Shelf brackets Model
More informationB/R Vacuum Distillation ASTM D1160. Fully Automatic Vacuum Distillation According to D1160
B/R Vacuum Distillation ASTM D1160 Fully Automatic Vacuum Distillation According to D1160 B/R Fully Automatic ASTM D1160 Vacuum Distillation Turn Key System: This system includes everything needed to automatically
More informationProcess controller. for pneumatic and electric actuators. Process controller V. Process controller
for pneumatic and electric actuators Process controller 110-240V Process controller dtron 316 in Rittal-cabinet with current loop sensor input for controlling pneumatic and electric actuators with a position
More informationINSTRUCTION MANUAL. TEC Controller/Thermocouple Thermometer
INSTRUCTION MANUAL Model 825A TEC Controller/Thermocouple Thermometer April 26, 2005, Revision 0 Copyright 2005 Aurora Scientific Inc. Aurora Scientific Inc. 360 Industrial Parkway S., Unit 4 Aurora, Ontario,
More informationOPERATION MANUAL. TZ Two Zone Controller
Maritime Stress PO Box 2898, 30 Estates Road Dartmouth, NS, B2W 4Y2, Canada Toll Free: 1-877-468-1781 Phone: (902) 468-7873 Fax: (902) 468-2304 Website: E-mail: info@maritimestress.com OPERATION MANUAL
More informationUninterruptible Power System
USER'S MANUAL Emergency Backup Power Supply For Use With Computer Loads Only Power Surge/Noise Protection Intelligent Auto-Shutdown Software Internet Line Protection Cost Efficiency UPS 1 st Edition Uninterruptible
More informationValveMate 7000 Controller Operating Manual
A NORDSON COMPANY ValveMate 7000 Controller Operating Manual Steady Test Clear Time Set Fast Slow POWER RUN SETUP CYCLE A NORDSON COMPANY VALVEMATE 7000 Run Setup Purge Program Fast Slow Time Set Pressure
More informationIKA Mixing Magnetic stirrers with heating
with heating RET basic safety control RET basic C safety control RET basic safety control IKAMAG, RET basic C safety control IKAMAG with new heating and stirring technology for fast, accurate temperature
More informationElectronic Charging Scales
Recovery YELLOW JACKET HVAC&R valves and Parts vacuum and hoses 68803 YELLOW JACKET Charging Scales Eliminates refrigerant transfer from tank to cylinder to system. The cylinder with refrigerant is weighed
More information2 0 1 7 D E F E Q U I P M E N T C ATA L O G 608-487-9770 www.hartlandlubes.com TD1 Features & Benefits: Great performance and quiet operation Self priming Stainless steel motor shaft Polypropylene housing
More informationDIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications
DIN-Rail DC UPS Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications Combines all system power functions: power supply, battery charger, UPS circuitry
More information348002K/348012K Manifold Block Style Service Manual 12/2000
348002K/348012K Manifold Block Style Service Manual 12/2000 Service Manual 348002K/348012K Manifold Block Style Recovery/Recycling/Recharging Unit For R-12 or R-134a Only TABLE OF CONTENTS: Theory of Operation
More informationThis pdf is chapter two of our Catalog Please refer to all five chapters to make the proper equipment choice for your needs.
This pdf is chapter two of our Catalog 4500. Please refer to all five chapters to make the proper equipment choice for your needs. Chapter 2 2 Stirred Reactors Reactor Selection Procedure: Basic Specifications
More informationHarris IRT Enterprises Digital Resistance Tester Model XP
Harris IRT Enterprises Digital Resistance Tester Model 5012-06XP Specifications & Dimensions 2 Theory of Operation 3 Operator Controls & Connectors 4 Test Connections 5 Calibration Procedure 6-7 Options
More informationSafety drying ovens. Advantages: Areas of application: FDL series 115
FDL series 115 Safety drying ovens Safety drying ovens The BINDER FDL with silicone and dust-free inner chamber, as well as symmetric airflow dries specimens containing solvents perfectly and thus meets
More informationVACUUM PUMP SYSTEMS. 99 Washington Street Melrose, MA Phone Toll Free Visit us at
VACUUM PUMP 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com RECOVERY YELLOW JACKET HVAC&R HOSE ADAPTERS, VALVES AND PARTS VACUUM
More informationWater Baths & Shaking Water Baths. Quality Technology for Routine Applications
Water Baths & Shaking Water Baths Quality Technology for Routine Applications 94 Water Baths and Shaking Water Baths The TW and SW Water Bath Series are microprocessor-controlled, durable, and long-lasting
More informationISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified.
ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified. Environmentally friendly Ultra Deep Freezer, -40 degree powered by Meditech Technology for safe storage. Stable Temperature Control Temperature is
More informationUSER MANUAL LVC-200TC DIGITAL THERMOCOUPLE VACUUM GAUGE
USER MANUAL LVC-200TC DIGITAL THERMOCOUPLE VACUUM GAUGE CONTACT US PHONE/FAX Toll Free: 800.465.1004 Phone: 801.486.1004 Fax: 801.486.1007 ADDRESS LACO Technologies, Inc. 3085 West Directors Row Salt Lake
More informationStirred Reactors and Pressure Vessels
P a r r I n s t r u m e n t C o m p a n y Stirred Reactors and Pressure Vessels Designing and Building Quality Pressure Apparatus for Over 100 Years Bulletin 4500 Volume 14 Start Chapter Two This pdf is
More information3000 SERIES DRY-BLOCK HEAT SOURCE
3000 SERIES DRY-BLOCK HEAT SOURCE USER MANUAL Please read this manual before switching the unit on IMPORTANT safety information inside TABLE OF CONTENTS 1 INTRODUCTION 1 2 SAFETY 2 3 OPERATION 3 3.1 Parts
More informationRemote on/off switch Connector for remote on/off switch available on all models. DIP switch for 50/60Hz selection (48/350 model only)
SinusMax Superior engineering Developed for professional duty, the Phoenix range of inverters is suitable for the widest range of applications. The design criteria have been to produce a true sine wave
More informationKomatsu Power Generation Systems
Komatsu Power Generation Systems Komatsu Air-to-Air aftercooled engine Advanced Air-to-Air aftercooled Engines have been introduced. EGS Series Generators are mounted with Komatsu engines that have High
More informationFlow Measurement Technology Training
Flow Measurement Technology Training Küppers Elektromechanik GmbH TASI Flow Division Küppers Elektromechanik GmbH TASI s Flow Group Territories Küppers Elektromechanik GmbH AW-Lake History AW Company formed
More informationUpgrade your blow molding machine with one of our two new state of the art machine control systems.
Upgrade your blow molding machine with one of our two new state of the art machine control systems. Uniloy is proud to introduce the Allen Bradley Compact Logix, and B&R Control Packages developed for
More informationFCI ST50 Series Flowmeters Low Cost, Low Maintenance Air, Compressed Air and Nitrogen Flow Measurement for Process and Plant Applications
FCI ST50 Series Flowmeters Low Cost, Low Maintenance ir, Compressed ir and Nitrogen Flow Measurement for Process and Plant pplications Wastewater Treatment eration Control lower and Dryer ir Flow Control
More informationWB 23 & WB 27. High-Speed Eddy-Current Dynamometers WB 23 & WB 27. Features. Description. Operating principles
WB 23 & WB 27 High-Speed Eddy-Current Dynamometers Magtrol offers 3 types of dynamometer brakes to absorb load: Hysteresis, Eddy-Current and Magnetic Powder. Each type of Dynamometer has advantages and
More informationQUANTUM LX CONTROL PANEL
Form E90-020 SPC (APR 2006) File: EQUIPMENT MANUAL - Section 90 Replaces: E90-020 SPC (JUN 2005) Dist: 1, 1a, 1b, 1c, 4a, 4b, 4c QUANTUM LX CONTROL PANEL The most technologically advanced screw compressor
More informationManufacturer of Custom Industrial / Laboratory Furnaces and Ovens
Manufacturer of Custom Industrial / Laboratory Furnaces and Ovens express-line express-line Furnaces 1100 C Split Tube for Process Tubes up to 2¾" Diameter 6" inner diameter heated chamber 1100º C (2000º
More informationCalibration Bench. The ultimate multifunction calibration station from Time Electronics TEMPERATURE PRESSURE ELECTRICAL SIGNALS
Calibration Bench The ultimate multifunction calibration station from Time Electronics TEMPERATURE PRESSURE ELECTRICAL SIGNALS Multimeters Clamp meters AC/DC signal sources RTD transmitters Signal generators
More informationFlow Limit Safety Shutoff Valves Model 1
Flow Limit Safety Shutoff Valves Model 1 Model 1 Series flow limit safety shutoff valves automatically shutoff all flow from the cylinder when flow exceeds a factory preset level. The Model 1 is normally
More informationPrecision Control Devices
Precision Control Devices Electro-Pneumatic Servo Pressure Controllers Electro-Pneumatic I/P, E/P, & P/I Transducers Diaphragm Regulators & Relays Diaphragm Cylinders Filter - Regulator - Lubricators Gauge
More informationDME Valve Gate Controls
DME ENERGY EFFICIENT, RELIABLE AND COMPACT HYDRAULIC AND PNEUMATIC CONTROLS 30 DME Valve Gate Controller Products and Solutions DME Valve Gate Controller Products and Solutions Solid-state timers and relays
More informationIndustries: Aerospace. Optical Electronics ASTM Test Ovens. Automotive. Automotive Components. Petroleum Curing Ovens. Ceramics
Products: Industries: Aerospace Equipment Industrial Ovens Aerospace Environmental Processing Optical Electronics ASTM Test Ovens New Energies Automotive Fabricated Metal Optics Conveyor Ovens Pharmaceutical
More informationProduct Guide AC Voltage Control Devices. Guide Guide. Popular Variable Transformers and AC Power Supplies.
Popular Variable Transformers and AC Power Supplies Product Guide AC Voltage Control Devices Guide Guide Your Tailored Power Solutions Provider TM Staco Energy Products Co. has been a leading manufacturer
More information2006/2007 Product Catalog. The World s Leading SOLAR Controllers
2006/2007 Product Catalog The World s Leading SOLAR Controllers OUR COMPANY Morningstar Corporation, founded in 1993, is the world s leading supplier of photovoltaic (PV) controllers. In 2005 we shipped
More informationCHAPTER 4 PARTS. 1234av This chapter describes assemblies/subassemblies/parts considered replaceable at on-site field installation.
CHAPTER 4 PARTS PARTS LIST 1234av This chapter describes assemblies/subassemblies/parts considered replaceable at on-site field installation. NOTE: The following is a breakdown description of the Serial
More informationUPGRADE YOUR BLOW MOLDING MACHINE WITH ONE OF OUR TWO NEW STATE OF THE ART MACHINE CONTROL SYSTEMS.
UPGRADE YOUR BLOW MOLDING MACHINE WITH ONE OF OUR TWO NEW STATE OF THE ART MACHINE CONTROL SYSTEMS. Uniloy is proud to introduce the Allen Bradley Compact Logix, and B&R Control Packages developed for
More informationCordless LED Lamps. Compatible with all standard leak detection dyes Powered by a rechargeable NiMH battery 120V, 230V, 240V or 100V smart AC charger
Cordless LED Lamps TP-8690UV OPTIMAX 365 Cordless, Rechargeable UV Leak Detection Flashlight (Patent Pending) Makes Even Dirty Diesel Engine Oil Leaks Glow Brightly! State-of-the-art, ultra-high intensity
More informationElectric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes
Electric Actuated Ball Valves 150 lb Flanged Stainless Steel, Full Port 1/2 to 4 inch Pipe Sizes SERIES Features Direct mount Full Port 16 Stainless Steel ball valve 2-piece ANSI Class 150 flanged body
More informationSECTION 8: STATOR WINDING SENSORS
SECTION 8: STATOR WINDING SENSORS Install between stator windings for continuous protection of motors and generators Increased safety sensors for use in hazardous areas Single and dual elements offer high
More informationPRODUCT SELECTION GUIDE 651, 1651, 153, 253, 653, and heated valves. Pressure Control Techniques. Dynamic Range
Valve Solutions w w w. m k s i n s t. c o m Downstream Pressure Controllers and Valves PRODUCT SELECTION GUIDE 651, 1651, 153, 253, 653, and heated valves Isolating and close-loop controlling each variable
More informationElectric Actuated 3-Way Ball Valves T-Port, Stainless Steel, Full Port 1/4 to 2 inch NPT
Electric Actuated 3-Way Ball Valves T-Port, Stainless Steel, Full Port 1/4 to 2 inch NPT SERIES Features Full Port 316SS diverter valve Polyamide IP67 weatherproof enclosure with UV protection Multi-voltage
More informationCorning Equipment Guide
Corning Equipment Guide Life Sciences Visit www.corning.com/lifesciences for additional product and technical information. Welcome to Corning Quality and Innovation New Products. More Features. Greater
More informationTHE INSIDE STORY OF THE QPV OR MPV:
BRQPVMPV0305E THE INSIDE STORY OF THE QPV OR MPV: Access Hole Permits Field Adjustments Electronic Control Circuit Available in a Wide Range of Electrical Control Inputs and Analog Outputs Many Connector
More informationAT30 SERIES BATTERY CHARGER
STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,
More informationPF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016
PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS v1.1 Revised Table of Contents 1 Common Alarms and Warnings... 1 2 Common Issues... 6 2.1 Communication problems... 6 2.1.1 Controller communication
More informationElectric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT
Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT SERIES Features Full Port 16 Stainless Steel ball valve LED light gives continuous status indication IP67 weatherproof polyamide
More informationElectric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT
Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 inch NPT SERIES Features Full Port 16 Stainless Steel ball valve LED light gives continuous status indication IP67 weatherproof polyamide
More information3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:
TECHNICAL GUIDE SPECIFICATIONS Power-Lite Single Phase, (200 to 490 Watts) UL924 Central Lighting Inverter 1. SCOPE The Emergency Lighting Power System shall be a solid-state single phase unit designed
More information1Valcor Scientific. Subminiature Teflon Valve. 2-Way, Normally Closed Solenoid Valve Model: SV20-1 APPLICATIONS FEATURES INTRODUCTION DESCRIPTION
1Valcor Scientific Subminiature Teflon Valve 2-Way, Normally Closed Solenoid Valve Model: SV20-1 APPLICATIONS Model SV20-1 is suitable for a broad range of light industrial applications, both new and retrofit.
More informationPrincipal Industrial Training Institute Bilaspur Details of Proposed Procurement under Shopping Mode
Public Disclosure Authorized Public Disclosure Authorized Public Disclosure Authorized Public Disclosure Authorized Principal Industrial Training Institute Bilaspur Details of Proposed Procurement under
More informationFURNACES. Includes Gas Flowmeter and Manifold! F (15) 73 FB cu. ft. (45)
Selection Guide MUFFLE (WITH CONTROLLER) Working Temperature Range Chamber Volume Type F C cu. in. (l) Page Thermolyne Quality - Low Price! FB1300 212-2012 100-1100 76 (1.3) 66 FB1400 212-2012 100-1100
More informationThe FMM force tester can be controlled using L1 software for limit, cycling, hold and coefficient of friction testing.
FMM FMM may be used with L1 software or with a Starrett DFC or DFG digital force gage. FMM digital force testers are compact and ideal for highvolume, lean manufacturing production. FMM testers are available
More informationFeatures and Benefits. Control Features
Features and Benefits AC induction motors have become increasingly dominant in industrial facilities worldwide. Manufacturers faced with increasing pressure to control costs have recognized that motor
More informationElectric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT
Electric Actuated Ball Valves 3-Piece Stainless Steel, Full Port 1/4 to 3 inch NPT SERIES Features Direct mount Full Port 316 Stainless Steel ball valve 3-piece swing out body designed for easy maintenance
More informationAT10.1 SERIES FLOAT BATTERY CHARGERS. Advanced technology microprocessor control
Motive Power Systems Reserve Power Systems Special Power Systems Service AT10.1 SERIES LOAT BATTERY CHARGERS UL-1564 CSA-C22.2 Seismic Zone 4 Qualification Advanced technology microprocessor control Constant
More informationParalleling Equipment
Paralleling Equipment PowerCommand Model 300 Digital Master Control Description The PowerCommand TM Digital MasterControl is a microprocessor-based paralleling system component, designed to directly interface
More informationPRESSURE TRANSDUCERS. Specifications. Individual Specifications
00 Series and 00 Heavy Duty Series Compact OEM Pressure Transmitters 0 50 psi to 0-0,000 psi ranges (0-.5 bar to 0-,00 bar) High Proof Pressures Broad Choice of Outputs RoHS Compliant For OEMs that need
More information