Universal push-button dimmer with PLC interference suppression, W, 2-wire

Size: px
Start display at page:

Download "Universal push-button dimmer with PLC interference suppression, W, 2-wire"

Transcription

1 Technical data sheet X - Universal flush-mounting rotary dimmer with PC interference suppression, W 4 year warranty R,,C CFi oads type of max. min. 325 W 325 W HA V 325 W CFi lamp (max. 10) (max. 10) 230 Vac ± 10%, 50 Hz flush-mounting box with flush-mounting depth of min. 40 mm Command rotary button o-load power consumption < 0.5 W housing temperature (Tc) 90 C wire diameter per connection terminal 2 x 2.5 mm² load Protection protected against thermal overload and short-circuit distance between dimmer and rotary button extension(s) ( x) 75 m Weight 70 g amp-specific dimmer curve adjustable (DIP switches) dimming level adjustable Standards Pack 1 xtension rotary button extension ( x) Up to five extra rotary button extensions can be connected to this dimmer. Finishing (or central plate) 1xx PD X-11 lamp

2 DATASHT Universal push-button dimmer with PC interference suppression, 3, 2-wire Base Dimmer for incandescent lamps, 230 V halogen lamps, all low-voltage halogen lamps and lamps. Connected with 2-wire system. The flush-mounting frame has internal dimensions of 45 x 45mm, centre-to-centre distance of 60 x 71 mm and is equipped with claw fixings. Finishing set XXX Finishing set for electronic switch or push button. Available in any iko finishing colours. Flush surround plate Can be combined with all single or multiple iko flush surround plates from the Original, Intense and Pure series. Base Base for universal push-button dimmer plus, 3-, with claw fixing Centraalplaat Cream White ight grey Greige Sterling Anthracite Bronze Dark brown White coated Champagne coated Black coated Bakelite piano black coated Alu steel grey coated Alu gold coated

3 DATASHT Technical data Minimum load Maximum load Maximum load lamps ight value memory xpansion control points Safety protections Interference suppression Power consumption standby Connection terminals Markering 230 Vac ± 10 %, 50 Hz push button - lamps (max. 10) Yes.O. push buttons, also in case of the replacement of single-pole, two-way or intermediate switching overload protection with automatic reset function electronic short-circuit protection CAB interference suppression 0,15 W 2 x 2,5 mm² + 35 C C-gemarkeerd oads amp lamp (max. 10) Wiring diagram 0 max. 30 x 230 Vac 230 Vac iko nv Industriepark West 40 B-9100 Sint-iklaas tel fax PD sales@niko.be

4 1X 1X DATASHT Universal rotary dimmer with powerline communication interference suppression, 3 -, 2-wired Base / Dimmer for incandescent lamps, 230 V halogen lamps, all low-voltage halogen lamps and lamps. Connected with 2-wire system. The flush-mounting frame has internal dimensions of 45 x 45mm, a centre-to-centre distance of 60 x 71 mm and is equipped with claw fixing ( ) or for screw fixing ( ). Finishing set XXX Finishing set for this rotary dimmer. Available in any iko finishing colours. Flush surround plate Can be combined with all single or multiple iko flush surround plates from the Original, Intense and Pure series. Base DFAUT HAO 2-3X Base for universal rotary dimmer 3 -, with claw fixing DFAUT HAO 2-3X Base for universal rotary dimmer 3 -, for screw fixing Central plate Cream White ight grey Greige Sterling Anthracite Bronze Dark brown White coated Champagne coated Black coated Bakelite piano black coated Alu steel grey coated Alu gold coated

5 DATASHT Technical data Minimum load Maximum load Maximum load lamps ight value memory xpansion control points Safety protections Interference suppression Power consumption standby Connection terminals Marking 230 V AC ± 10%, 50 Hz Rotary dimmer - lamps (max. 10) yes.o. push buttons, also in case of the replacement of single-pole, two-way or intermediate switching overload protection with automatic reset function electronic short-circuit protection PC interference suppression 0.15 W 2 x 2,5 mm² 35 C C marked oads amp lamp (max. 10) O HA 3X 2-0 DF 1X AUT O HA 3X 2- DF 1X AUT Wiring diagram max. 30 x 230 Vac 230 Vac iko nv Industriepark West 40 B-9100 Sint-iklaas tel fax PD x-11 sales@niko.be

6 Technical data sheet ew universal dimmer 5 W to 4 year warranty R,,C CFi oads amp HA.230 V 230 Vac ± 10%, frequency 50 Hz DI rail (1 TU) O or potential-free (8 24 V) Own consumption ± 0.6 W temperature of housing (Tc) 90 C terminal HA V CFi 2.5 mm² Power supply and load Input load Protection Protection against thermal overload and short-circuit Push buttons 230 Vac; 5 ma (not galvanically isolated) or 8 24 Vdc (variable voltage) -5 C + 55 C distance to the last push button 100 m Weight 70 g amp-specific dimmer curve Adjustable (DIP switches) dimming level Adjustable xtra functions All off staircase function light value memory Standards Packaging 1 PD R11383 wire diameter per connection PD indd 3 HA.230 V 21/09/11 11:16

7 Technical data sheet ew universal dimmer 5 W to : analogue 4 year warranty R,,C CFi oads amp HA.230 V HA.230 V 230 Vac ± 10%, frequency 50 Hz DI rail (1 TU) 1 10 V current control ± 0.6 W temperature of housing (Tc) 90 C terminal CFi 0 10 V voltage control Own consumption wire diameter per connection HA V 2.5 mm² Power supply and load Input load Protection Protection against thermal overload and short-circuit -5 C + 55 C Input impedance 0 10 V: 33 kω PD indd 3 distance to the last push button 100 m Weight 70 g amp-specific dimmer curve Adjustable (DIP switches) dimming level Adjustable Standards Packaging 1 PD R V: 22 kω 21/09/11 11:15

General catalogue INTERNATIONAL

General catalogue INTERNATIONAL General catalogue 2018-2019 INTERNATIONAL Let yourself be guided through the catalogue. overview of our flush surround plates. Product photography Niko Published by Niko nv, Industriepark West 40 BE-9100

More information

Transformers for Low-voltage Halogen Incandescent Lamps

Transformers for Low-voltage Halogen Incandescent Lamps Transformers for Low-voltage Halogen Incandescent Lamps Independent electronic converters 10 14 With DLI interface 14 Electronic built-in converters 15 17 Potentiometer and dimmers 18 Electromagnetic safety

More information

Wiring devices Asfora 2015 catalogue

Wiring devices Asfora 2015 catalogue Wiring devices 05 catalogue Contents Presentation Products with cover frame (white, cream) Switches and push-buttons 6 Socket-outlets 8 Communication outlets 9 Dimmers 0 ccessories Products without cover

More information

Wiring Accessories. low voltage. Wiring Accessories

Wiring Accessories. low voltage. Wiring Accessories Wiring Accessories About CBI-electric: CBI-electric: is a South African company with more than half a century of experience in the design and manufacture of a comprehensive range of technically advanced

More information

Pack Cat.Nos Switches16A-250VA. 1 gang - standard switches One-way switch Two-way switch Intermediate switch

Pack Cat.Nos Switches16A-250VA. 1 gang - standard switches One-way switch Two-way switch Intermediate switch switches, automatic switches 7 758 06 Aluminium finish 7 758 20 Aluminium finish 7 758 05 Aluminium finish 7 756 55 Pearl finish 7 756 57 Aluminium finish To be equipped with cover plates (p. 475 to 481)

More information

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control of rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in ventilation and air conditioning

More information

Pack Cat. Nos. Single pole push switches gang 2 way push switch gang 2 way push switch marked PRESS gang 2 way

Pack Cat. Nos. Single pole push switches gang 2 way push switch gang 2 way push switch marked PRESS gang 2 way white 7300 00 7300 02 7300 07 7301 07 7301 33 7300 06 7300 08 7300 09 Terminal screws captive and backed off ready for cabling Surface mounting boxes (see p. 112) Pack Cat. os. Single pole plate switches

More information

SWITCHES - 230V. available as double push-buttons (i.e. 2 functions per lever) and as a regular switch.

SWITCHES - 230V. available as double push-buttons (i.e. 2 functions per lever) and as a regular switch. SWITCHES - 230V CJC offers 2 collections for main voltage installations. The LISA collection exists out of flat push-buttons. These push-buttons can be used with impulse relays (installed in the electrical

More information

Installation & User Instructions

Installation & User Instructions Installation & User Instructions 16/25A Digital Dimmer (416/425) INTRODUCTION The 416 and 425 are Digital Dimmers capable of dimming a single channel with total loads of up to 16A and 25A respectively.

More information

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED Dimming Controller for 110V* & 220V/ 240V AC LED Systems Thank you for purchasing high quality

More information

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module transformers and buzzers and bells socket outlets and special supports 042 25 042 52 041 07 042 80 042 85 Pack Cat.Nos Bell transformers dconform to IEC / EN 61558-2-8 Protected against overloads and short

More information

ELECTRIC POWER REGULATION TEMPERATURE CONTROLLERS. room C

ELECTRIC POWER REGULATION TEMPERATURE CONTROLLERS. room C ELECTRIC POWER REGULATION STS converts 0 10 V signal to one time proportional and up to 3 contact. Each step must be identical in power. input output 1 2- number of steps 2 Vac, 1 VA 0 10 Vdc < 1 ma for

More information

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version)

UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version) UNIVERSAL PUSHBUTTON DIMMER ETD 2 (Rail mount version) With central control inputs, front button and various operating modes and functions General purpose, user-friendly electronic pushbutton dimmer for

More information

Operating Instructions. Tronic Dimmer

Operating Instructions. Tronic Dimmer Operating Instructions 1. Warning Caution! The installation and assembly of electrical equipment may only be performed by a skilled electrician. Not suitable for disconnecting. The load is not galvanically

More information

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series ST 50 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output voltage < 60 V DC ow

More information

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version

Emergency lighting units EM Inverter. EM SELFTEST G2, V SELFTEST version T5 T8 TC- TC-F DE TC- TC-SE TC-TE TC-DD T5c EM SEFTE, 220 240 V SEFTEST version Product description Emergency lighting supply unit with self-test function For linear and compact fluorescent lamps ow-profile

More information

CONTROL UNITS LOCAL EXTRACTORS LOCAL EXTRACTORS. Pure advantage

CONTROL UNITS LOCAL EXTRACTORS LOCAL EXTRACTORS. Pure advantage CONTROL UNITS LOCAL EXTRACTORS Fumex s control unit offers a good working environment, adapted to all types of facilities. The right choice of control units is also very energy-saving and provides the

More information

Power Switching Devices

Power Switching Devices Watlow has manufactured solid state power controllers for over forty years. Watlow s is a microprocessor-based product that features application flexibility unmatched by any other silicon controlled rectifier

More information

1 Phase electronic contactor (SC 1)

1 Phase electronic contactor (SC 1) 1 Phase electronic contactor (SC 1) - Rated operational voltage up to 600VAC 50/60 Hz - Rated operational current up to 15/30A/50/63A AC-1 - Control voltage from or - Compact modular design 22.5, 45, or

More information

Millenium Functionality is more than switching on or off

Millenium Functionality is more than switching on or off Millenium Functionality is more than switching on or off 2 MIEIUM SOUTIOS FOR EECTRICA ISTAATIO I BUIDIGS Find exactly what you are looking for. The Millenium series offers control, functionality and convenience

More information

DELTA i-system. 1/6 Introduction. 1/7 Switches and pushbuttons. 1/13 Shutter/blind controls. 1/19 Socket outlets

DELTA i-system. 1/6 Introduction. 1/7 Switches and pushbuttons. 1/13 Shutter/blind controls. 1/19 Socket outlets 1 1/6 Introduction 1/7 Switches and pushbuttons 1/13 Shutter/blind controls 1/19 Socket outlets 1/25 International plug-and-socket devices 1/26 Lighting controls 1/29 Motion detectors 1/31 Room temperature

More information

CI-TI Contactors and Motor Starters Type CI 6-50

CI-TI Contactors and Motor Starters Type CI 6-50 Data sheet CI-TI Contactors and Motor Starters CI 6-50 CI-TI contactors and motor starters provide trouble-free switching and maximum protection for costly motors and other electrical equipment. The components

More information

PD-Series Ground Fault Circuit Protection

PD-Series Ground Fault Circuit Protection PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized

More information

ICG Switchgear Price List 2009

ICG Switchgear Price List 2009 ICG Switchgear Price List 2009 Section 1 Control Gear Page Contactors (AC,DC & Modular) 2,3 Overload Relays 4 Product Accessories 4,5 Starters-DOL, Star-Delta, Fan/Vibrators, Reversing/Twin 6,7 Section

More information

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point

Power consuption motor (motion) Power consuption standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control of spring return actuator Description Spring-return actuator for adjusting and regulating dampers and valves in air conditioning and ventilation. Torque

More information

Clarian uk ltd SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC.

Clarian uk ltd SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC TOP-TECHNIC. SWITCHES AND CONTROLS TOP-TECHNIC TOP-TECHNIC CONTROL UNITS SWITCH DISCONNECTORS & CAM SWITCHES TOP-TECHNIC TOP-TECHNIC EMERGENCY STOP MAIN SWITCHES MAIN SWITCHES TOP-TECHNIC TOP-TECHNIC CAM SWITCHES FOR

More information

Standard Features 200-600V, 50/60Hz input power supply Built-in run rated (AC1) By-pass contactor up to 820 A * Rated 450% current Conformal coated circuit board Voltage ramp or current limit start modes

More information

Installation. Mounting frames - TECHNICAL CHARACTERISTICS. Conformity to Standards LV Directive EN Standard

Installation. Mounting frames - TECHNICAL CHARACTERISTICS. Conformity to Standards LV Directive EN Standard Installation Mounting frames - TECHNICAL CHARACTERISTICS Technical specifications polycarbonate (Glow Wire 850 C) dielectric strength 2000 V honeycomb structure of stiffening Conformity to Standards LV

More information

EMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com

EMUJC Series. Electronic actuator. Technical Data Sheet. WattsIndustries.com EMUJC Series Electronic actuator Technical Data Sheet WattsIndustries.com Description Watts Water Technologies, Inc. The actuator EMUJC Series is an electronic device with 3-point or proportional control

More information

1 Safety instructions. 2 Device components. Dimmer push-button/2-way low voltage. Order No. : Operating instructions

1 Safety instructions. 2 Device components. Dimmer push-button/2-way low voltage. Order No. : Operating instructions Dimmer push-button/2-way low voltage Order No. : 2262 00 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries,

More information

Grosvenor Plus 138 decorative Solid brass highly polished, with rope-edge detail Pre-treated heat-cured powder lacquer finish Total safety

Grosvenor Plus 138 decorative Solid brass highly polished, with rope-edge detail Pre-treated heat-cured powder lacquer finish Total safety 38 Grosvenor Plus wiring devices decorative www.mkelectric.co.uk range introduction feature benefits Grosvenor Plus stylish solid brass and elegant rope-edge detail combine in an extensive range exclusively

More information

FIRE CONTROL

FIRE CONTROL 48 FIRE CONTROL FIRE HOLD OPEN MAGNETS HYDRAULIC DAMPERS FOR SLIDING DOORS HYDRAULIC IMPACT SHOCK ABSORBERS SINGLE ZONE FI RE CONTROLLER FIRE AND SMOKE DETECTORS 49 50 FIRE CONTROL www.opera-italy.com

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

18000 series Snap-action momentary pushbutton switches

18000 series Snap-action momentary pushbutton switches Distinctive features and specifications Panel and PC mount models Snap-in panel mounting version Tactile feedback ELECTRICAL SPECIFICATIONS Max. current/voltage rating with resistive load : Models for

More information

Local Control Network - building controls in perfection

Local Control Network - building controls in perfection 2 1 F3,15A250V 2 1 1 2 F3,15A250V Installation guide Local Control Network - building controls in perfection Sensor/actuator module for DIN-rail mounting The is a sensor/actuator module for building installation

More information

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS

Power Supply. & Door Controllers 238 SECURITY DOOR CONTROLS Security Door Controls & Door Controllers 5 SDC Access Control Power Supplies have been developed specifically to support access controls and electric locking hardware with clean, consistent power. Combined

More information

1 Safety instructions. 2 Device components. Light Management Rotary dimmer. Operating instructions

1 Safety instructions. 2 Device components. Light Management Rotary dimmer. Operating instructions with 2-way push switch with 2-way push switch Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire

More information

Application. Battery. Public Grid GS HYBRID INVERTER

Application. Battery. Public Grid GS HYBRID INVERTER GS HYBRID SOLAR INVERTER Feed from Solar and Power, Grid backup, Build-in Transfer Switch / Solar Charger/ AC Charger, 500W~3kW, Pure Sine Wave Output GSH-15XX and GSH-30XX are the ideal solutions for

More information

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay DG 14 drawn out from the case The type DG 14 relay is a heavily damped

More information

JUMO MIDAS Pressure transmitter

JUMO MIDAS Pressure transmitter Phone: +44 19 635533 Fax: +44 19 6356 Data Sheet 401001 Page 1/5 JUMO MIDAS Pressure transmitter Brief description Pressure transmitters are used for measuring the relative (gauge) pressure in liquids

More information

DIMMERS. Slide Dimmers C3. Rotary Dimmers. Touch Dimmers C5. Decorator Dimmers C6 C-1

DIMMERS. Slide Dimmers C3. Rotary Dimmers. Touch Dimmers C5. Decorator Dimmers C6 C-1 DIMMERS ENERLITES dimmers can add lighting control flexibility to individual or multiple spaces. They allow users to adjust lighting levels to meet their individual needs in residences, offices, schools,

More information

8000 series Momentary or alternate action pushbutton switches

8000 series Momentary or alternate action pushbutton switches Distinctive features and specifications ushing Ø 6,35 (1/4) and Ø 11,9 (15/32) UL approved ELECTRICAL SPECIFICATIONS Max. current/voltage rating with resistive load : - silver contacts : 3A 250VAC - 6A

More information

ATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor

ATL 12 ACME SCREW LINEAR ACTUATOR OVERALL DIMENSIONS. La =Lc + Stroke Lc T. Rear bracket SP. Stroke. Capacitor ACME SCREW LINEAR ACTUATOR Stroke OVERALL DIMENSIONS La =Lc + Stroke Lc T Capacitor Rear bracket SP Pin Standard head with threaded hollow bore BA depth 17 Stroke end reed switches FCM Lenght Stroke 300

More information

ADEL - BARA NESO - NG

ADEL - BARA NESO - NG - With simple and super-thin design, luminaires looks very modern. With delicate structure of radiator, luminaires is more powerful in heat sinking and can reach IP66. Multiple choose for installation,

More information

Solar off-grid Inverter. SP Junior Series. User Manual

Solar off-grid Inverter. SP Junior Series. User Manual Solar off-grid Inverter SP Junior Series User Manual Contents 1 PREFACE... 3 1.1 Glossary... 3 2 INTRODUCTI... 3 2.1 Description... 3 2.2 Features... 3 2.3 Appearance... 3 3 INSTALLATI... 4 3.1 Safety...

More information

LED CONVERTERS FOR LED MODULES 24 V

LED CONVERTERS FOR LED MODULES 24 V LED Constant Voltage Devices for LED Modules 24 V LED CONVERTERS FOR LED MODULES 24 V Electronic Converters for LED Modules 24 V If LED modules are used that are connected in parallel, this system is activated.

More information

3.5 Amp Bi-polar stepper motor drive MSE570 Evo 2

3.5 Amp Bi-polar stepper motor drive MSE570 Evo 2 3.5 Amp Bi-polar stepper motor drive MSE57 Evo 2 Features Bi-polar drive with pre-set drive currents up to 3.5 Amps per phase Increased operating voltage up to 48 V ½ step drive option for improved damping

More information

Graze MX Powercore high-intensity illumination of multistorey. surfaces. ew Graze MX Powercore. Benefits. Features

Graze MX Powercore high-intensity illumination of multistorey. surfaces. ew Graze MX Powercore. Benefits. Features Lighting Graze MX Powercore high-intensity illumination of multistorey façades and surfaces ew Graze MX Powercore Many architectural structures need a linear fixture capable of illuminating multiple storeys

More information

Dimmer / 2-Way Dimmer

Dimmer / 2-Way Dimmer Dimmer / 2-Way Dimmer Model No. JSJSLW455 Instruction Manual Connect Series www.lightwaverf.house Version 2 EC DECLARATION OF CONFORMITY Responsible Authority: LightwaveRF PLC, Innovation Campus Birmingham

More information

1 Safety instructions. 2 Device components. Light Management LED touch dimmer insert. Art. No LEDDE. Operating instructions

1 Safety instructions. 2 Device components. Light Management LED touch dimmer insert. Art. No LEDDE. Operating instructions Art. No. 1271 LEDDE Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible.

More information

Replace ** for the required coil voltage eg: P7 (230V 50/60Hz) Co nt act or Heating Guides, 9-95A

Replace ** for the required coil voltage eg: P7 (230V 50/60Hz) Co nt act or Heating Guides, 9-95A Co nt act or Heating Guides, 9-95A switching in the event of prolonged overloads at 1.05 Un. 220 / 240V 380 / 415V 660 / 690V 4 7 12 D1210** 2 Pole 5 9 15.5 D1810** 6 11 19 D2510** 8.5 15 25.5 D3210**

More information

2.7. IT system floor-standing distribution cabinet Series -IPS-F

2.7. IT system floor-standing distribution cabinet Series -IPS-F Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str. 65 35305 Grünberg Tel.: 0640 07-0 Fax: 0640 07-25 IT system floor-standing distribution cabinet Series -IPS-F for supplying power to medical locations

More information

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data TC2000 TC2001 EUROTHERM ONTROLS Two phase thyristor power switches Product data TC2000 TC2001 Thyristor power switches Compact, two phase thyristor power switches for electrical heating applications from

More information

Wall Light, 1x11W IP20. Mounting 4 mounting holes, Ø 5 mm

Wall Light, 1x11W IP20. Mounting 4 mounting holes, Ø 5 mm Wall Light, 1x11W WL 39 Type 230V/50Hz/ l.p.f. 230V/60Hz/ h.p.f.c. WL39 5127 0030..-001 5127 0030.. 1. other voltages on request brass Diffuser PC, opal G 23 tubular compact fluorescent lamp 11W resistant

More information

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series ST 90 V SEFTEST series Product description lighting Driver with self-test function For self-contained emergency lighting For modules with a forward voltage of 40 97 V SEV for output voltage < 120 V DC

More information

9000 SERIES SUBMINIATURE MOMENTARY PUSHBUTTON SWITCHES Overview

9000 SERIES SUBMINIATURE MOMENTARY PUSHBUTTON SWITCHES Overview A 9000 SERIES Overview 9 SERIES Number of poles 3 Single pole Electrical functions 2 Normally closed (NC) 3 Normally open (NO) Terminals, case and bushing Case height 8 (.314) 2 Straight terminals - threaded

More information

1SVC F SVC F 0607 R100.20/30 R100.45

1SVC F SVC F 0607 R100.20/30 R100.45 SIGMASWITCH Content Solid state relays Description, certificates, approvals... 163 Ordering details... 164 Technical data R111, R12x... 167 Technical data R100... 168 Technical data HDS R2... 169 Selection

More information

Emergency lighting units EM INVERTER

Emergency lighting units EM INVERTER T T8 TC- TC-F DE TC- TC-SE TC-TE TC-DD Tc EM, 0 40 V 0/0 Hz PRO version Product description Emergency lighting supply unit with DAI interface and automatic test function For linear and compact fluorescent

More information

GP12 TECHNICAL MANUAL

GP12 TECHNICAL MANUAL GP12 D i g i t a l l y C o n t r o l l e d D i m m e r R a c k TECHNICAL MANUAL Contents i Table of Contents Table of Contents... i 1.0 Introduction... 1-1 2.0 Equipment Description... 2-1 2.1 Front panel

More information

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos: PHASE CONVERTERS MODEL NO: PC40 and PC60 MODEL PART No: NO: 6012805 PC20 and PC40 6012810 PC60 PART Nos: 6012800 6012805 6012810 OPERATING & MAINTENANCE INSTRUCTIONS 0107 Specifications PC20 PC40 PC60

More information

MX431 Generator Automatic Voltage Regulator Operation Manual

MX431 Generator Automatic Voltage Regulator Operation Manual Generator Automatic Voltage Regulator Operation Manual Self Excited Automatic Voltage Regulator 1 1. SPECIFICATION Sensing Input Voltage Frequency 190 ~ 264 VAC Max, 1 phase, 2 wire 50 / 60 Hz, selectable

More information

Pushbutton switches & indicators. Panel Sealed to IP65. Push on tab terminals 6A 250VAC AGENCY APPROVALS

Pushbutton switches & indicators. Panel Sealed to IP65. Push on tab terminals 6A 250VAC AGENCY APPROVALS Distinctive features and specifications A01_AX1607US Panel Sealed to IP65 Single pole to four pole changeover Custom engraving or film legends options Push on tab terminals 6A 250VAC PANEL CUT OUT ELECTRICAL

More information

CI-TI Contactors and motor starters Types CI 61 - CI 98

CI-TI Contactors and motor starters Types CI 61 - CI 98 Data sheet CI-TI Contactors and motor starters s CI 6 - CI 98 Contactors CI 6, CI 7, CI 86 and CI 98 switch powers of up to 0 kw, 7 kw, 45 kw and 55 kw respectively under 80 V - loads. Accessories include

More information

TS-350 Fully-Flush Under Vehicle Inspection Light Packages

TS-350 Fully-Flush Under Vehicle Inspection Light Packages General Description The flush-mounted fixture is designed to aid security and safety inspectors by providing high-intensity illumination of vehicle undercarriages. Features include outstanding durability,

More information

2-Way Dimmer (1 Gang)

2-Way Dimmer (1 Gang) lightwaverf 2-Way Dimmer (1 Gang) Model Nos. JSJSLW450 Instruction Manual Connect Series www.megamanuk/lightwaverf.com Get Started How do I get started? If the Dimmer has already been installed, refer

More information

FR circuit breaker - hydraulic magnetic,

FR circuit breaker - hydraulic magnetic, FR circuit breaker - hydraulic magnetic, Datasheet railway, very high current Features Ideal for very high current applications Precise, temperature independent operation Panel mount Integrated auxiliary

More information

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH

More information

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. LB management. Universal touch dimmer insert LED Art. no.: 1711DE Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property damage possible. Please

More information

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter Features TRIAC Dimmable LED Driver Triac dimmable with leading or trailing edge dimmers Class II with SELV output (no earth required) Extra-large screw terminals and integrated cable clamps for easy installation

More information

CONSUMER LIGHTING PRODUCT CATALOGUE

CONSUMER LIGHTING PRODUCT CATALOGUE CONSUMER LIGHTING PRODUCT CATALOGUE WIPRO LED ADVANTAGES Reduce Energy Bills Saves energy upto 6% over CFL Long Life 6 times longer life than CFL Environment Friendly No UV, no infrared & zero mercury

More information

DPX moulded case circuit breakers

DPX moulded case circuit breakers BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations.

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

Pushbutton switches & indicators. Panel Sealed to IP65. Push on tab terminals 6A 250VAC AGENCY APPROVALS

Pushbutton switches & indicators. Panel Sealed to IP65. Push on tab terminals 6A 250VAC AGENCY APPROVALS Distinctive features and specifications Panel Sealed to IP65 Single pole to four pole changeover Custom engraving or film legends options Push on tab terminals 6A 250VAC A01_AX1607USR1 ELECTRICAL SPECIFICATIONS

More information

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point

Power consuption Motor (Motion) Power consuption Standby (end position) Auxiliary switch Contact load Switching point Actuators Technical data sheet Continuous control rotary drive without spring return Description Actuator for adjusting air dampers of 90 angle of rotation to be used in HVAC installations. Torque Motor

More information

SERIES 1000 ELECTRIC ACTUATORS

SERIES 1000 ELECTRIC ACTUATORS DESIGN FEATURES Series 1000 On-Off Rotary Electric Actuator Basic Actuator: Torque Output Range: 347in-lb to 17,359in-lb Housing: NEMA 4X, watertight, corrosion-resistant, robust aluminum die cast Electric

More information

Electronic Circuit Breaker ESS20-0..

Electronic Circuit Breaker ESS20-0.. Electronic Circuit Breaker ES-0.. Description Electronic circuit breaker type ES-0.. is designed to ensure selective disconnection of individual loads in systems which are powered by a DC 4 V switch-mode

More information

Step A decisive step forward

Step A decisive step forward Step A decisive step forward 54 ABB, the world leader in the manufacture and design of high quality switches, presents the new Step series. With over 100 years experience manufacturing switches, ABB has

More information

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCD ECO, W Compact and T5c fluorescent lamps

PHASED OUT. Digital dimmable ballasts for fluorescent lamps ECO series. PCA TCD ECO, W Compact and T5c fluorescent lamps Product description oise-free precise control via signal or switchdim CELMA energy class A1 1) Interfaces switchdim Integrated SMART-Interface Functions Optimum filament heating in any dimmer setting Automatically

More information

Series Motor Protection

Series Motor Protection 320-327 Series Motor Protection Relay Physical Address: 298 Soutter Street, Pretoria West Tel: 083 454 6949, +27 12 327 1729 Fax: +27 (0)12 327 1733 Toll Assist: 0860 10 30 41 www.newelec.co.za sales@newelec.co.za

More information

Prewired position switches FF series

Prewired position switches FF series 2 Prewired position switches FF series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45 46

More information

Mini Contactors CI 4-

Mini Contactors CI 4- Data sheet Mini Contactors CI 4- Introduction CI 4 minicontactors cover the power range 1.5 to 5.9 kw and are available for a.c. and d.c. coil voltages. Characteristic of the minicontactors is that they

More information

General_technical_data Series

General_technical_data Series Slow-make switching element Switching system The double-break, slow-make switching element is equipped with one or two independent contact systems, acting as normally open or normally closed contact. The

More information

ACTUATORS POSITION SENSOR

ACTUATORS POSITION SENSOR POSITION SENSOR 1 2 SUMMARY P INTRODUCTION PAGE 4 P LTS POSITION SENSOR PAGE 5 P LTL POSITION SENSOR PAGE 9 SUMMARY P LTE POSITION SENSOR PAGE 12 3 INTRODUCTION INTRODUCTION Magnetic position sensors are

More information

5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps

5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps 5 Series - Mechanical Latch 2PDT - 4PST, 30 Amps The 5 series is a 2 coil mechanical latch electrical reset power relay. It is panel mounted with screw terminals, and has 600 volt spacing. The 5 series

More information

Ionizer. Discharge time: 0.3 seconds. Series IZS31. Ion balance control by an autobalance sensor CAT.EUS100-68A-UK. Without sensor.

Ionizer. Discharge time: 0.3 seconds. Series IZS31. Ion balance control by an autobalance sensor CAT.EUS100-68A-UK. Without sensor. Ionizer 2 types of sensors are available. Rapid elimination of static electricity by a feedback sensor Continuously emits ions in accordance with the detected polarity of a workpiece. Supply pressure:

More information

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series EM converter EM converter PRO 200 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage

More information

LED CANOPY with j-box

LED CANOPY with j-box ASD Garage Canopy Luminaire with junction box provides a slim, low profile solution for easy mounting. Built with rugged cast aluminum, this luminaire is available with surface or pendant mount. J-Box

More information

Merilux. Lamps for surgery and examination

Merilux. Lamps for surgery and examination Merilux Lamps for surgery and examination Merilux Camera-/monitor system for operating rooms The Merivaara Merilux Vision series is designed for use in multiple locations in modern health care, where transferring

More information

LEDtape 800 TW Tunable White K CRI>90

LEDtape 800 TW Tunable White K CRI>90 LEDtape 800 TW Tunable White 2400-6000K CRI>90 IP20/IP65 Highlights Flexible tunable white LED-tape for professional lighting applications Adjustable color temperature 2400-6000K Simulate everything from

More information

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series PRO 50 V PRO series Product description lighting Driver with DAI interface and automatic test function For self-contained emergency lighting For modules with a forward voltage of 10 52 V SEV for output

More information

2-Way Dimmer (1 Gang)

2-Way Dimmer (1 Gang) 2-Way Dimmer (1 Gang) Model No. JSJSLW450 Instruction Manual Connect Series www.lightwaverf.house Version 2 EC DECLARATION OF CONFORMITY Responsible Authority: LightwaveRF PLC, Innovation Campus Birmingham

More information

LED light engines ready2apply. Engine SLA AC G2 50mm SNC Engine SLA ESSENCE

LED light engines ready2apply. Engine SLA AC G2 50mm SNC Engine SLA ESSENCE Engine SLA AC G2 5mm SNC Engine SLA ESSENCE Product description Fits in most existing MR16 / GU1 halogen luminaires 1 W LED Equivalent to 5 W MR16 halogen with higher lumen output Perfect solution for

More information

DELTA natur 77/1 7/1. 7/6 Frames. 7/7 Switches and pushbuttons. 7/9 Outlets. 7/10 Lighting control. 7/11 Shutter/blind control. 7/12 Communication

DELTA natur 77/1 7/1. 7/6 Frames. 7/7 Switches and pushbuttons. 7/9 Outlets. 7/10 Lighting control. 7/11 Shutter/blind control. 7/12 Communication 7/6 Frames 7/7 Switches and pushbuttons 7/9 Outlets 7/10 Lighting control 7/11 Shutter/blind control 7/12 Communication 7/13 TV / RF / SAT 7/14 Accessories and spare parts 7 77/1 7/1 Want to give your

More information

ELECTRICAL PANELS. Chap.

ELECTRICAL PANELS. Chap. ELECTRICAL PANELS 360 Panel System Electrical Panels 360 Panel System Modular Panels DC Electric Panels AC Electric Panels AC/DC Electric Panels Aber Marine Panels IP 67 Watertight Panels Rotary Switch

More information

Prewired position switches FF series

Prewired position switches FF series 2 Prewired position switches FF series Distributed buy Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable

More information

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number

ST48-WHUV.102. Wiring diagram. Product description. PID controller. Order number ST48-WHUV.12 PID controller Order number 935.15 Wiring diagram Product description This micro-processed controller serves for temperature control at high measuring accuracy. Beside resistance sensors and

More information

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's

More information

THYRISTORS T2-2PH from 45A to 2700A Specifications Universal 2 Phase Thyristor Unit , March 2012

THYRISTORS T2-2PH from 45A to 2700A Specifications Universal 2 Phase Thyristor Unit , March 2012 Technical Information THYRISTORS T-PH from 5A to 700A Specifications Universal Phase Thyristor Unit 55-77-03-63, March 0 GENERAL DESCRIPTION THYRISTORS T-PH is a full digital and universal Thyristor unit

More information

RSS Series Panel Mount Solid State Relays. 4,000 RMS (minute)

RSS Series Panel Mount Solid State Relays. 4,000 RMS (minute) RSS Series Panel Mount Solid State Relays Key features of the RSS series include: Photo isolation 1,200 volt blocking voltage 4,000 volt optical isolation Zero voltage turn-on 100% tested at rated current

More information

Electronic Temperature Sensor ETS 300

Electronic Temperature Sensor ETS 300 Description: The ETS 300 is a compact electronic temperature sensor with digital display. Two different models are available for optimum adaptation to particular applications. The ETS 300 with built-in

More information