Series 45 Axial Piston Open Circuit Pumps. Technical Information

Size: px
Start display at page:

Download "Series 45 Axial Piston Open Circuit Pumps. Technical Information"

Transcription

1 Series 45 Axial Piston Open Circuit Pumps Technical Information

2 Revisions History of Revisions Table of Revisions Date Page Changed Rev. September dimension changes for Frame J FJ June 28 78, 93, 94, 95 various minor edits, removed S5 shaft from Frame E FI May 28 32, 74, 75, 92 correction to schematics drawings FH April correction to S2 spline width (inch measurement only) FG April 28 52, 53 correction to schematics drawings FG April 28 27, 5, 72, 89 add Load sensing - RP and BP must be 2 bar FF April Correction to S2 shaft - Class 6 and mm length FF March 28 4 Correction to TOC FE February 28 Various Add LS setting to specifications for each frame FD December 27 Various Relocate F and E sections, add displacement limiter info. FC November 27 5 Change load sensing setting - bar increments FB September 27 Various Add Frame F, remove Frame G, and many edits FA November 26 51, 52, 53 Revised schematics information E August 25 - Removed Frame H, added Frame J D April 23 Added Frame E C May 21 - Added Frame H and Frame G B May First printing A 28 Sauer-Danfoss. All rights reserved. Sauer-Danfoss accepts no responsibility for possible errors in catalogs, brochures and other printed material. Sauer-Danfoss reserves the right to alter its products without prior notice. This also applies to products already ordered provided that such alterations aren t in conflict with agreed specifications. All trademarks in this material are properties of their respective owners. Sauer-Danfoss and the Sauer-Danfoss logotype are trademarks of the Sauer-Danfoss Group. Front cover illustrations: F11 178, F11 18, F11 337, F11 168, P L519 Rev FJ September 28

3 Contents General information Overview... 6 Design... 6 Typical applications... 6 High performance... 6 Latest technology... 6 Reliability... 6 The Series 45 product family... 7 Basic units... 7 Load sensing open circuit system... 8 Pressure compensated controls... 9 Operation... 9 Pressure compensated system characteristics... 9 Typical applications for pressure compensated systems... 9 Remote pressure compensated controls...1 Remote pressure compensated system characteristics...1 Typical applications for remote pressure compensated systems...1 Load sensing controls...11 Operation...11 Load sensing system characteristics...11 Typical applications for load sensing systems...11 Electrical on/off pressure compensated controls...12 Operating parameters...13 Fluids...13 Viscosity...13 Temperature...13 Inlet pressure...13 Case pressure...13 Pressure ratings...14 Speed ratings...14 Duty cycle and pump life...14 Speed, flow, and inlet pressure...14 Design parameters...15 Installation...15 Filtration...15 Reservoir...15 Fluid velocity...16 Shaft loads...16 Bearing life...16 Mounting flange loads...17 Auxiliary mounting pads...18 Input shaft torque ratings...18 Understanding and minimizing system noise...19 Sizing equations...2 Frames L and K Design...21 Specifications...22 Performance L25C...23 Performance L3D...24 Performance K38C...25 Performance K45D...26 Order code L519 Rev FJ September 28 3

4 Contents Frames L and K (continued) Controls...29 Pressure compensated control (PC)...29 Remote PC control (RP)...29 Load sensing control (LS)...3 Load sensing control with internal bleed orifice (LB)...3 Normally closed on/off electric PC control (ED)...31 Normally open on/off electric PC control (AA)...31 Electric proportional control (EJ) (Normally closed)...32 Input shafts...33 Auxiliary mounting pads...35 SAE-A auxiliary mounting pad...35 SAE-B auxiliary mounting pad...35 SAE-A Auxilliary Pad...36 Mounting pads at 9 degrees...36 Running cover...36 Special SAE-A 11 tooth...36 Displacement limiter...37 Installation drawings...38 Axial ported endcap...38 Radial ported endcap...4 Electric on/off control...42 Frame J Design...43 Specifications...44 Performance J45B...45 Performance J51B...46 Performance J6B...47 Performance J65C...48 Performance J75C...49 Order code...5 Controls...52 Pressure compensated control (PC, BC)...52 Remote PC control (RP, BP)...52 Load sensing control (LS, BS)...53 Load sensing control with internal bleed orifice (LB, BB)...53 Normally closed on/off electric PC control (AG)...54 Normally open on/off electric PC control (AF)...54 Input shafts...55 Auxiliary mounting pads...58 SAE-A auxiliary mounting pad (non-integral)...58 SAE-B auxiliary mounting pad...58 Displacement limiter...59 SAE-C auxiliary mounting pad...6 Running cover...6 Installation drawings...61 Axial ported endcap...61 Radial ported endcap...64 Electric on/off control/radial endcap L519 Rev FJ September 28

5 Contents Frame F Design...68 Specifications...69 Performance F74B...7 Performance F9C...71 Order code...72 Controls...74 Pressure compensated control (PC)...74 Remote PC Control (RP)...74 Load sensing control with internal bleed orifice (LB)...75 Load sensing control (LS)...75 Input shafts...76 Auxiliary mounting pads...77 SAE-A auxiliary mounting pad...77 SAE-B auxiliary mounting pad...77 Displacement limiter...78 SAE-C auxiliary mounting pad...78 Adjustable displacement limiter and running cover...79 Axial ported endcap...8 Radial ported endcap...82 Frame E Design...84 Specifications...85 Performance E1B...86 Performance E13B...87 Performance E147C...88 Order code...89 Controls...91 Pressure compensated control (PC)...91 Remote PC control (RP)...91 Load sensing control (LS)...92 Load sensing control with internal bleed orifice (LB)...92 Input shafts...93 Auxiliary mounting pads...95 SAE-A auxiliary mounting pad...95 SAE-B auxiliary mounting pad...95 SAE-C auxiliary mounting pad...96 Running cover...96 Displacement limiters...97 Installation drawings...98 Axial ported endcap, clockwise rotation...98 Axial ported endcap, counterclockwise rotation... 1 Radial ported endcap, clockwise rotation Radial ported endcap, counterclockwise rotation L519 Rev FJ September 28 5

6 General information Overview Series 45 is a complete family of variable displacement, axial piston pumps for open circuit applications. Each frame within the Series 45 family is uniquely designed to optimize performance, size, and cost, matching the work function requirements of the demanding mobile equipment marketplace. Design High performance Displacements from 25 cm³ cm³ [ in 3 /rev] Speeds up to 36 rpm Pressures up to 31 bar [4495 psi] continuous, and 4 bar [58 psi] peak Variety of control system options including load sensing and pressure compensated Through-drive capability for multi-circuit systems Range of mounting flanges, shafts, and porting options for ease of installation Latest technology Customer-driven using quality function deployment (QFD) and design for manufacturability (DFM) techniques Optimized valve plates for maximum efficiency and quiet operation Computer-modeled castings to optimize inlet conditions for maximum pump speed Compact package size minimizing installation space requirements Heavy-duty tapered roller bearings for long life Single piece rigid housing to reduce noise and leak paths Integrated controls for high speed response and system stability Reliability Designed to rigorous standards Proven in both laboratory and field Manufactured to rigid quality standards Long service life Significantly fewer parts No gasketed joints Robust input shaft bearings to handle large external shaft loads Integrated gauge ports for monitoring operating conditions Typical applications Cranes Telescopic handlers Forklift trucks Wheel loaders Sweepers Backhoe loaders Forestry and agricultural machinery Fan drives Other uses 6 52L519 Rev FJ September 28

7 General information The Series 45 product family Basic units The series 45 family of open circuit, variable piston pumps, offers a range of displacements from 25 to 147 cm³/rev [1.53 to 8.97 in 3 /rev]. With maximum speeds up to 36 rpm and continuous operating pressures up to 31 bar [4495 psi], you can tailor product selection to the flow and pressure requirements of your individual application. K/L Frame J Frame F Frame E Frame General performance specifications for the series 45 pump family Speed Pressure Theoretical flow Pump Displacement Mounting Continuous Max. Min. Continuous Maximum (at rated speed) Model cm 3 in 3 min -1 (rpm) min -1 (rpm) min -1 (rpm) bar psi bar psi US gal/min l/min Flange Frame L See page 21 L25C SAE B - 2 bolt L3D SAE B - 2 bolt Frame K See page 21 K38C SAE B - 2 bolt K45D SAE B - 2 bolt J45B J51B J6B See page 43 SAE B 2-bolt SAE C 2 and 4-bolt SAE B 2-bolt SAE C 2 and 4-bolt SAE B 2-bolt SAE C 2 and 4-bolt J65C SAE B 2-bolt SAE C 2 and 4-bolt J75C SAE B 2-bolt SAE C 2 and 4-bolt Frame F See page 68 F74B SAE B 2-bolt SAE C 4-bolt F9C SAE B 2-bolt SAE C 4-bol Frame E See page 84 E1B SAE C 4-bolt E13B SAE C 4-bolt E147C SAE C 4-bolt 52L519 Rev FJ September 28 7

8 General information Load sensing open circuit system The pump receives fluid directly from the reservoir through the inlet line. A screen in the inlet line protects the pump from large contaminants. The pump outlet feeds a PVG-32 multi-section, load sensing, directional control valve. The PVG valve directs pump flow to the cylinder and gear motor. A heat exchanger cools the fluid returning from the valve. A filter cleans the fluid before it returns to the reservoir. Flow in the circuit determines the speed of the actuators. The position of the PVG valve determines the flow demand. A hydraulic pressure signal (LS signal) communicates demand to the pump control. The pump control monitors the pressure differential between pump outlet and the LS signal, and regulates servo pressure to control the swashplate angle. Swashplate angle determines pump flow. Actuator load determines system pressure. The pump control monitors system pressure and will decrease the swashplate angle to reduce flow if system pressure reaches the PC setting. A system relief valve in the PVG valve acts as a back-up to control system pressure. Pictorial circuit diagram K/L Frame Series 45 open circuit axial piston pump with load sensing control PVG 32 mulit-section load sensing control valve Double-acting cylinder Bi-directional gear motor System pressure Reservoir Filter Heat exchanger Servo pressure Actuator pressure Load sense pressure Actuator return P11 658E Suction / case drain / system return 8 52L519 Rev FJ September 28

9 General information Pressure compensated controls Operation The PC control maintains constant system pressure in the hydraulic circuit by varying the output flow of the pump. Used with a closed center control valve, the pump remains in high pressure standby mode at the PC setting with zero flow until the function is actuated. This condition is often called a dead head condition. Typical operating curve Q max Simple closed-center circuit Flow Pressure PC setting P11 166E Once the closed center valve is opened, P the PC control senses the immediate drop in system pressure and increases pump flow by increasing the swashplate angle. The pump continues to increase flow until system pressure reaches the PC setting. If system pressure exceeds the PC setting, the PC control reduces the swashplate angle to maintain system pressure by reducing flow. The PC control continues to monitor system pressure and changes swashplate angle to match the output flow with the work function pressure requirements. If the demand for flow exceeds the capacity of the pump, the PC control directs the pump to maximum displacement. In this condition, actual system pressure depends on the actuator load. For additional system protection, install a relief valve in the pump outlet line. Each section includes control schematic diagrams, setting ranges, and response / recovery times for each control available. Response is the time (in milliseconds) for the pump to reach zero displacement when commanded by the control. Recovery is the time (in milliseconds) for the pump to reach full displacement when commanded by the control. Actual times can vary depending on application conditions. Pressure compensated system characteristics Constant pressure and variable flow High pressure standby mode when flow is not needed System flow adjusts to meet system requirements Single pump can provide flow to multiple work functions Quick response to system flow and pressure requirements Typical applications for pressure compensated systems Constant force cylinders (bailers, compactors, refuse trucks) On/off fan drives 52L519 Rev FJ September 28 9

10 General information Remote pressure compensated controls The remote PC control is a two-stage control that allows multiple PC settings. Remote PC controls are commonly used in applications requiring low and high pressure PC operation. Typical operating curve Q max Closed center circuit with remote PC Flow Remote PC setting Pressure PC setting P11 969E P The remote PC control uses a pilot line connected to an external hydraulic valve. The external valve changes pressure in the pilot line, causing the PC control to operate at a lower pressure. When the pilot line is vented to reservoir, the pump maintains a low standby pressure of 15 to 2 bar [215 to 3 psi]. When pilot flow is blocked, the pump maintains pressure at the PC setting. An on-off solenoid valve can be used in the pilot line to create a low-pressure standby mode. A proportional solenoid valve, coupled with a microprocessor control, can produce an infinite range of operating pressures. Each section includes control schematic diagrams, setting ranges, and response / recovery times for each control available. Response is the time (in milliseconds) for the pump to reach zero displacement when commanded by the control. Recovery is the time (in milliseconds) for the pump to reach full displacement when commanded by the control. Actual times can vary depending on application conditions. Size the external valve and plumbing for a pilot flow of 3.8 l/min [1 US gal/min]. For additional system protection, install a relief valve in the pump outlet line. Remote pressure compensated system characteristics Constant pressure and variable flow High or low pressure standby mode when flow is not needed System flow adjusts to meet system requirements Single pump can provide flow to multiple work functions Quick response to system flow and pressure requirements Typical applications for remote pressure compensated systems Modulating fan drives Anti-stall control with engine speed feedback Front wheel assist 1 52L519 Rev FJ September 28

11 General information Load sensing controls Operation The LS control matches system requirements for both pressure and flow in the circuit regardless of the working pressure. Used with a closed center control valve, the pump remains in low-pressure standby mode with zero flow until the valve is opened. The LS setting determines standby pressure. Typical operating curve Load sensing circuit Q max Flow Pressure PC setting P11 968E P Most load sensing systems use parallel, closed center, control valves with special porting that allows the highest work function pressure (LS signal) to feed back to the LS control. Margin pressure is the difference between system pressure and the LS signal pressure. The LS control monitors margin pressure to read system demand. A drop in margin pressure means the system needs more flow. A rise in margin pressure tells the LS control to decrease flow. LS control with bleed orifice The load sense signal line requires a bleed orifice to prevent high-pressure lockup of the pump control. Most load-sensing control valves include this orifice. An optional internal bleed orifice is available, if needed. Integral PC function The LS control also performs as a PC control, decreasing pump flow when system pressure reaches the PC setting. The pressure compensating function has priority over the load sensing function. For additional system protection, install a relief valve in the pump outlet line. Each section includes control schematic diagrams, setting ranges, and response / recovery times for each control available. Response is the time (in milliseconds) for the pump to reach zero displacement when commanded by the control. Recovery is the time (in milliseconds) for the pump to reach full displacement when commanded by the control. Actual times can vary depending on application conditions. Load sensing system characteristics Variable pressure and flow Low pressure standby mode when flow is not needed System flow adjusted to meet system requirements Single pump can supply flow and regulate pressure for multiple circuits Quick response to system flow and pressure requirements Typical applications for load sensing systems Priority steering Load independent flow control for boom lift, tilt, and rotation 52L519 Rev FJ September 28 11

12 General information Electrical on/ off pressure compensated controls The electrical on/off pressure compensated control allows the pump to operate as a PC type control under normal operating conditions. A solenoid valve overrides the PC control allowing the pump to operate in a low-pressure standby mode. This function provides reduced horsepower and torque loss in certain situations. It may be particularly useful to reduce loads on a system during engine start. ED schematic (normally closed) S When closed, the solenoid valve prevents L1 P16 44 flow across the LS spool gain orifice, defeating the LS spool. The pump then functions as a PC control pump. When open, the solenoid valve allows flow across the LS spool gain orifice to reservoir. This flow generates a pressure differential across the LS spool that shifts the spool and de-strokes the pump. The pump then operates in a low-pressure standby condition. The solenoid valve is available in a normally closed or normally open configuration. M2 L2 B X ED is the nomenclature for a normally closed on/off control for the L and K frame pumps. Other frame sizes and configurations have different order code designations. (ED) Electric control cross-section System pressure Servo pressure Pilot Pressure Drain Solenoid LS adjustment LS spool PC adjustment PC spool P16 183E 12 52L519 Rev FJ September 28

13 General information Operating parameters Fluids Ratings and performance data for Series 45 products are based on operating with premium hydraulic fluids containing oxidation, rust, and foam inhibitors. These include premium turbine oils, API CD engine oils per SAE J183, M2C33F or G automatic transmission fluids (ATF), Dexron II (ATF) meeting Allison C-3 or Caterpillar T 2 requirements, and certain specialty agricultural tractor fluids. For more information on hydraulic fluid selection, see Sauer-Danfoss publications 52L463 Hydraulic Fluids and Lubricants,, and 52L465 Experience with Biodegradable Hydraulic Fluids,. Viscosity Maintain fluid viscosity within the recommended range for maximum efficiency and bearing life. Minimum viscosity should only occur during brief occasions of maximum ambient temperature and severe duty cycle operation. Maximum viscosity should only occur at cold start: Limit speeds until the system warms up. Fluid viscosity limits Condition mm 2 /s (cst) SUS ν min. ν max. continuous 9 58 intermittent continuous 11 5 intermittent (cold start) 1 47 Temperature Maintain fluid temperature within the limits shown in the table. Minimum temperature relates to the physical properties of the component materials. Cold oil will not affect the durability of the pump components. However, Temperature limits Minimum (intermittent, cold start) - 4 C [- 4 F] Continuous 82 C [18 F] Maximum 14 C [22 F] it may affect the ability of the pump to provide flow and transmit power. Maximum temperature is based on material properties. Don t exceed it. Measure maximum temperature at the hottest point in the system. This is usually the case drain. Ensure fluid temperature and viscosity limits are concurrently satisfied. Inlet pressure Maintain inlet pressure within the limits shown in the table. Low inlet pressure (vacuum) may limit maximum pump speed and cause cavitation. Refer to Inlet pressure vs. speed charts for each displacement. Case pressure Maintain case pressure within the limits shown in the table. The housing must always be filled with hydraulic fluid. Inlet pressure limits Minimum (continuous) Minimum (cold start).8 bar absolute [6.7 in. Hg vac.] (at reduced maximum speed).5 bar absolute [15.1 in. Hg vac.] Case pressure limits Maximum.5 bar [7 psi] above inlet (continuous) Intermittent 2 bar [29 psi] above inlet (cold start) C Caution Operating outside of inlet and case pressure limits will damage the pump. To minimize this risk, use full size inlet and case drain plumbing, and limit line lengths. 52L519 Rev FJ September 28 13

14 General information Operating parameters (continued) Pressure ratings The specification tables in each section give maximum and continuous pressure ratings for each displacement. Not all displacements within a given frame operate under the same pressure limits. Definitions of the operating pressure limits appear below. System pressure is the differential pressure between the outlet and inlet ports. It is the dominant operating variable affecting hydraulic unit life. High system pressure, which results from high load, reduces expected life. System pressure must remain at or below rated pressure during normal operation to achieve expected life. Continuous working pressure is the average, regularly occurring operating pressure. Operating at or below this pressure should yield satisfactory product life. For all applications, the load should move below this pressure. Maximum (peak) working pressure is the highest intermittent pressure allowed. Maximum machine load should never exceed this pressure. Speed ratings The specification tables in each section give minimum, maximum, and rated speeds for each displacement. Not all displacements within a given frame operate under the same speed limits. Definitions of these speed limits appear below. Rated speed is the maximum recommended operating speed at full displacement and 1 bar abs. [ in Hg vac] inlet pressure. Operating at or below this speed should yield satisfactory product life. Maximum speed is the highest recommended operating speed at full power conditions. Operating at or beyond maximum speed requires positive inlet pressure and/or a reduction of pump outlet flow. Refer to Inlet pressure vs. speed charts for each displacement. Minimum speed is the lowest operating speed allowed. Operating below this speed will not yield satisfactory performance. Duty cycle and pump life Knowing the operating conditions of your application is the best way to ensure proper pump selection. With accurate duty cycle information, your Sauer-Danfoss representative can assist in calculating expected pump life. Speed, flow, and inlet pressure Inlet pressure vs. speed charts in each section show the relationship between speed, flow, and inlet pressure for each displacement. Use these charts to ensure your application operates within the prescribed range. The charts define the area of inlet pressures and speeds allowed for a given displacement. Operating at lower displacements allows greater speed or lower inlet pressure L519 Rev FJ September 28 Sample inlet pressure vs. speed chart Inlet Pressure (bar abs) Max. speed Rated speed 1% 9% 8% Shaft Speed min (rpm) (psi gauge) (in Hg vac) P11 972E Operating limit at 8% displacement Operating limit at 9% displacement Operating limit at 1% displacement

15 General information Design parameters Installation Series 45 pumps may be installed in any position. To optimize inlet conditions, we recommend installing the pump at an elevation below the minimum reservoir fluid level. Design inlet plumbing to maintain inlet pressure within prescribed limits (see Inlet pressure limits, page 13) Fill the pump housing and inlet line with clean fluid during installation. Connect the case drain line to the uppermost drain port (L1 or L2) to keep the housing full during operation. To allow unrestricted flow to the reservoir, use a dedicated drain line. Connect it below the minimum reservoir fluid level and as far away from the reservoir outlet as possible. Use plumbing adequate to maintain case pressure within prescribed limits (see Case pressure limits, page 13). Filtration To prevent damage to the pump, including premature wear, fluid entering the pump inlet must be free of contaminants. Series 45 pumps require system filtration capable of maintaining fluid cleanliness at ISO class 22/18/13 or better. Sauer-Danfoss does not recommend suction line filtration. Suction line filtration can cause high inlet vacuum, which limits pump operating speed. Instead we recommend a 125 µm (15 mesh) screen in the reservoir covering the pump inlet. This protects the pump from coarse particle ingestion. Return line filtration is the preferred method for open circuit systems. Consider these factors when selecting a system filter: Cleanliness specifications Contaminant ingression rates Flow capacity Desired maintenance interval Typically, a filter with a beta ratio of β 1 = 1 is adequate. However, because each system is unique, only a thorough testing and evaluation program can fully validate the filtration system. For more information, see Sauer-Danfoss publication 52L467 Design Guidelines for Hydraulic Fluid Cleanliness. Reservoir The reservoir provides clean fluid, dissipates heat, and removes entrained air from the hydraulic fluid. It allows for fluid volume changes associated with fluid expansion and cylinder differential volumes. Minimum reservoir capacity depends on the volume needed to perform these functions. Typically, a capacity of one to three times the pump flow (per minute) is satisfactory. Locate the reservoir outlet (suction line) near the bottom, allowing clearance for settling foreign particles. Place the reservoir inlet (return lines) below the lowest expected fluid level, as far away from the outlet as possible. 52L519 Rev FJ September 28 15

16 General information Design parameters (continued) Velocity equations Fluid velocity Choose piping sizes and configurations sufficient to maintain optimum fluid velocity, and minimize pressure drops. This reduces noise, pressure drops, and overheating. It maximizes system life and performance. SI units Q = flow (l/min) A = area (mm²) Recommended fluid velocities System lines 6 to 9 m/sec [2 to 3 ft/sec] Suction line Case drain 1 to 2 m/sec [4 to 6 ft/sec] 3 to 5 m/sec [1 to 15 ft/sec] Typical guidelines; obey all pressure ratings. US units Q = flow (US gal/min) A = area (in²) Velocity = Q A (m/sec) Velocity =.321 Q A (ft/sec) Shaft loads Series 45 pumps have tapered roller bearings capable of accepting external radial and thrust loads. The external radial shaft load limits are a function of the load position, orientation, and the operating conditions of the pump. The maximum allowable radial load (R e ) is based on the maximum external moment (M e ) and the distance (L) from the mounting flange to the load. Compute radial loads using the formula below. Tables in each section give maximum external moment (M e ) and thrust load (T in, T out ) limits for each pump frame size and displacement. Radial load formula M e = R e L Shaft load orientation Re L = Distance from mounting flange to point of load M e = Maximum external moment R e = Maximum radial side load 9 Re 27 Re T out T in Re Axis of swashplate rotation L Re 21 Mounting flange P11 8E Bearing life All shaft loads affect bearing life. In applications where external shaft loads can not be avoided, maximize bearing life by orientating the load between the 15 and 21 positions, as shown. We recommend tapered input shafts or clamp-type couplings for applications with radial shaft loads. Tables in each section give B 1 bearing life for each pump frame size and displacement L519 Rev FJ September 28

17 General information Design parameters (continued) Mounting flange loads Adding auxiliary pumps and/or subjecting pumps to high shock loads may overload the pump mounting flange. Tables in each section give allowable continuous and shock load moments for each frame size. Applications with loads outside allowable limits require additional pump support. Shock load moment (M S ) is the result of an instantaneous jolt to the system. Continuous load moments (M c ) are generated by the typical vibratory movement of the application. Estimating overhung load moments Use the equations below to estimate the overhung load moments for multiple pump mounting. See installation drawings in each section to find the distance from the mounting flange to the center of gravity for each frame size. Refer to the technical specifications in each section to find pump weight. Overhung load example mounting flange Center of Gravity (CG) pump 1 Center of Gravity (CG) pump 2 L1 L2 P11 81E Shock load formula Continuous load formula M s = G s K (W 1 L 1 +W 2 L W n L n ) M c = G c K (W 1 L 1 +W 2 L W n L n ) SI units M s = Shock load moment (N m) M c = Continuous (vibratory) load moment (N m) G s = Acceleration due to external shock (G s) G c = Acceleration due to continuous vibration (G s) K = Conversion factor =.981 W n = Mass of n th pump (kg) L n = Distance from mounting flange to n th pump CG (mm) US units M s = Shock load moment (lbf in) M c = Continuous (vibratory) load moment (lbf in) G s = Acceleration due to external shock (G s) G c = Acceleration due to continuous vibration (G s) K = Conversion factor = 1 W n = Weight of n th pump (lb) L n = Distance from mounting flange to n th pump CG (in) 52L519 Rev FJ September 28 17

18 General information Design parameters (continued) Auxiliary mounting pads Auxiliary mounting pads are available for all radial ported Series 45 pumps. Since the auxiliary pad operates under case pressure, use an O-ring to seal the auxiliary pump mounting flange to the pad. Oil from the main pump case lubricates the drive coupling. All mounting pads meet SAE J744 Specifications. The combination of auxiliary shaft torque and main pump torque must not exceed the maximum pump input shaft rating. Tables in each section give input shaft torque ratings for each frame size. Applications subject to severe vibratory or shock loading may require additional support to prevent mounting flange damage. Tables in each section give allowable continuous and shock load moments for each frame size. The drawing and table below give mating pump dimensions for each size mount. Refer to installation drawings in each section for auxiliary mounting pad dimensions. Mating pump specifications Mounting flange (ref) mm [in.] P11 79E Undercut spline Sled-runner spline B max. C max. D max. E max. Coupling F min. spline engagement for full torque rating P Ø [+ -.2] Recommended cutter clearance 2.3 [.9] R.8 [.3] max. Dimensions SAE A SAE B SAE C P B C D E F [3.25] 6.35 [.25] 12.7 [.5] 58.2 [2.29] 15. [.59] 13.5 [.53] 11.6 [4.] 9.65 [.38] 15.2 [.6] 53.1 [2.9] 17.5 [.69] 14.2 [.56] 127. [5.] 12.7 [.5] [.92] 55.6 [2.19] 3.5 [1.2] 18.3 [.72] Input shaft torque ratings Input shaft tables in each section give maximum torque ratings for available input shafts. Ensure that your application respects these limits. Maximum torque ratings are based on shaft strength. Do not exceed them. Coupling arrangements that are not oil-flooded provide a reduced torque rating. Contact your Sauer-Danfoss representative for proper torque ratings if your application involves non oil-flooded couplings. Sauer-Danfoss recommends mating splines adhere to ANSI B92.1-Class 5. Sauer-Danfoss external splines are modified class 5 fillet root side fit. The external major diameter and circular tooth thickness dimensions are reduced to ensure a good clearance fit with the mating spline. Tables in each section give full spline dimensions and data L519 Rev FJ September 28

19 General information Design parameters (continued) Understanding and minimizing system noise Tables in each section give sound levels for each frame size and displacement. Sound level data are collected at various operating speeds and pressures in a semi-anechoic chamber. Many factors contribute to the overall noise level of any application. Here is some information to help understand the nature of noise in fluid power systems, and some suggestions to help minimize it. Noise is transmitted in fluid power systems in two ways: as fluid borne noise, and structure borne noise. Fluid-borne noise (pressure ripple or pulsation) is created as pumping elements discharge oil into the pump outlet. It is affected by the compressibility of the oil, and the pump s ability to transition pumping elements from high to low pressure. Pulsations travel through the hydraulic lines at the speed of sound (about 14 m/s [46 ft/sec] in oil) until there is a change (such as an elbow) in the line. Thus, amplitude varies with overall line length and position. Structure-borne noise is transmitted wherever the pump casing connects to the rest of the system. The way system components respond to excitation depends on their size, form, material, and mounting. System lines and pump mounting can amplify pump noise. Follow these suggestions to help minimize noise in your application: Use flexible hoses. Limit system line length. If possible, optimize system line position to minimize noise. If you must use steel plumbing, clamp the lines. If you add additional support, use rubber mounts. Test for resonants in the operating range, if possible avoid them. 52L519 Rev FJ September 28 19

20 General information Sizing equations Use these equations to help choose the right pump size and displacement for your application: Based on SI units Based on US units Flow Output flow Q = V g n η v 1 (l/min) Output flow Q = V g n η v 231 (US gal/min) Torque Input torque M = V g p 2 π η m (N m) Input torque M = V g p 2 π η m (lbf in) Power M n π Q p Input power P = = (kw) 3 6 η t M n π Q p Input power P = = (hp) η t Variables SI units [US units] V g = Displacement per revolution cm 3 /rev [in 3 /rev] p O = Outlet pressure bar [psi] p i = Inlet pressure bar [psi] p = p O - p i (system pressure) bar [psi] n = Speed min -1 (rpm) η v = Volumetric efficiency η m = Mechanical efficiency η t = Overall efficiency (η v η m ) 2 52L519 Rev FJ September 28

21 Frames L and K Design Series 45 Frame L and K pumps have a single servo piston design with a cradletype swashplate set in polymer-coated journal bearings. A bias spring and internal forces increase swashplate angle. The servo piston decreases swashplate angle. Nine reciprocating pistons displace fluid from the pump inlet to the pump outlet as the cylinder block rotates on the pump input shaft. The block spring holds the piston slippers to the swashplate via the slipper retainer. The cylinder block rides on a bimetal valve plate optimized for high volumetric efficiency and low noise. Tapered roller bearings support the input shaft and a viton lip-seal protects against shaft leaks. An adjustable one spool (PC only, not shown) or two spool (LS and remote PC) control senses system pressure and load pressure (LS controls). The control ports system pressure to the servo piston to control pump output flow. Frame K/L cross section LS adjustment screw LS control (attached to endcap) LS spool PC spool PC adjustment screw Endcap (axial ported) Swashplate Bias spring Servo piston Tapered roller bearing Valve plate Block spring Tapered roller bearing Cylinder block Input shaft Shaft seal Piston Slipper retainer Slipper P11 659E 52L519 Rev FJ September 28 21

22 Frames L and K Specifications Features and options Model For general operating parameters, including fluid viscosity, temperature, and inlet and case pressures, see page 13. For system design parameters, including installation, filtration, reservoir, and line velocities, see page 15. Feature Unit L25C L3D K38C K45D Maximum Displacement cm³ [in³] 25 [1.53] 3 [1.83] 38 [2.32] 45 [2.75] Flow at rated speed (theoretical) Input torque at maximum displacement (theoretical) Mass moment of inertia of internal rotating components l/min [US gal/min] N m/bar [lbf in/1 psi] kg m² [slug ft²] 8 [21].398 [243].169 [.125] 96 [25.4].477 [291].161 [.119] 1.7 [26.6].65 [369].184 [.135] Weight Axial ports kg [lb] 19 [42] Radial ports 24 [53] Rotation Clockwise, Counterclockwise Mounting Auxiliary mounting (See page 35) System ports (type) System ports (location) Control types (See page 29) SAE-B SAE-A, SAE-B, SAE-BB SAE O-ring boss Axial, Radial [31.5].716 [438].23 [.15] EP, ED, AA, PC, Remote PC, LS, LS with internal bleed Shafts (See page 33) Splined 13 tooth, 15 tooth Displacement limiters (See page 37) Tapered Straight Ø 25.4 mm [1 in], 1:8 taper Ø mm [.875 in], 1:8 taper Ø mm [.875 in] (short) Optional, adjustable Ø mm [.875 in] (long) For definitions of pressure and speed ratings, see page 14. For more information on external shaft loads, see page 16; mounting flange loads, see page 17. Ratings Model Rating Units L25C L3D K38C K45D Input speed¹ minimum min -1 (rpm) continuous maximum Working pressure continuous bar [psi] 26 [377] 21 [345] 26 [377] 21 [345] External shaft loads maximum 35 [575] 3 [435] 35 [575] 3 [435] External moment (M e ) N m [lbf in] 61 [54] 61 [54] 76 [673] 76 [673] Thrust in (T in ), out (T out ) N [lbf ] 1 [225] 1 [225] 12 [27] 12 [27] Bearing life at 14 bar [23 psi] B 1 hours Mounting flange load moments at 21 bar [345 psi] at 26 bar [377 psi] Vibratory (continuous) N m [lbf in] 15 [8895] Shock (max) 355 [31 42] 1. Input speeds are valid at 1 bar absolute [ in Hg vac] inlet pressure. See Inlet pressure vs. speed charts. For more information on noise levels, see page 19. Sound levels² db(a) 21 bar [345 psi] 26 bar [377 psi] Pump model 18 min -1 (rpm) Rated speed 18 min -1 (rpm) Rated speed L25C L3D 66 7 K38C K45D Sound data was collected in a semi-anechoic chamber. Values have been adjusted (-3 db) to reflect anechoic levels L519 Rev FJ September 28

23 Frames L and K Performance L25C Flow and power data valid at 49 C [12 F] and viscosity of 17.8 mm²/sec [88 SUS]. Flow vs. speed Flow (l/min) Flow (US gal/min) Speed min (rpm) P11 97E Input power vs. speed 5 Power (kw) bar [377 psi] 21 bar [345 psi] 14 bar [23 psi] Power (hp) Speed min (rpm) P11 971E The chart on the right shows allowable inlet pressure and speed at various displacements. Greater speeds and lower inlet pressures are possible at reduced displacement. Operating outside of acceptable limits reduces pump life. Inlet pressure vs. speed Inlet Pressure (bar abs) Shaft Speed min (rpm) 1% 9% 8% (psi gauge) (in Hg vac) P11 972E 52L519 Rev FJ September 28 23

24 Frames L and K Performance L3D Flow and power data valid at 49 C [12 F] and viscosity of 17.8 mm²/sec [88 SUS]. Flow vs. speed Flow (l/min) Flow (US gal/min) Speed min (rpm) P11 973E Input power vs. speed 5 6 Power (kw) bar [345 psi] 14 bar [23 psi] Power (hp) Speed min (rpm) P11 974E The chart on the right shows allowable inlet pressure and speed at various displacements. Greater speeds and lower inlet pressures are possible at reduced displacement. Operating outside of acceptable limits reduces pump life. Inlet pressure vs. speed Inlet Pressure (bar abs) % 9% 8% Shaft Speed min (rpm) (psi gauge) (in Hg vac) P11 972E 24 52L519 Rev FJ September 28

25 Frames L and K Performance K38C Flow and power data valid at 49 C [12 F] and viscosity of 17.8 mm²/sec [88 SUS]. Flow vs. speed Flow (l/min) Flow (US gal/min) Speed min (rpm) P11 975E Input power vs. speed 6 8 Power (kw) bar [377 psi] 14 bar [23 psi] Power (hp) Speed min (rpm) P11 976E The chart on the right shows allowable inlet pressure and speed at various displacements. Greater speeds and lower inlet pressures are possible at reduced displacement. Operating outside of acceptable limits reduces pump life. Inlet pressure vs. speed Inlet Pressure (bar abs) % 9% 8% Shaft Speed min (rpm) (psi gauge) (in Hg vac) P11 977E 52L519 Rev FJ September 28 25

26 Frames L and K Performance K45D Flow and power data valid at 49 C [12 F] and viscosity of 17.8 mm²/sec [88 SUS]. Flow vs. speed Flow (l/min) Flow (US gal/min) Speed min (rpm) P11 978E Input power vs. speed 6 8 Power (kw) bar [345 psi] 14 bar [23 psi] Power (hp) Speed min (rpm) P11 979E The chart on the right shows allowable inlet pressure and speed at various displacements. Greater speeds and lower inlet pressures are possible at reduced displacement. Operating outside of acceptable limits reduces pump life. Inlet pressure vs. speed Inlet Pressure (bar abs) % 9% 8% Shaft Speed min (rpm) (psi gauge) (in Hg vac) P11 977E 26 52L519 Rev FJ September 28

27 Frames L and K Order code J K R S P C D E F G H L M N R KR LR S L R Product K Frame, variable displacement open circuit pump L Frame, variable displacement open circuit pump Rotation Left hand (counterclockwise) Right hand (clockwise) P Displacement and pressure rating 25C 25 cm³/rev [1.53 in³/rev], 26 bar [377 psi] continuous working pressure 3D 38C 45D 3 cm³/rev [1.83 in³/rev], 21 bar [345 psi] continuous working pressure 38 cm³/rev [2.32 in³/rev], 26 bar [377 psi] continuous working pressure 45 cm³/rev [2.75 in³/rev], 21 bar [345 psi] continuous working pressure C Control type PC Pressure compensated control RP LS LB ED EP AA Remote pressure compensated control Load sensing / pressure compensating control Load sensing / pressure compensating control with internal bleed orifice Normally closed on/off electric PC control Normally closed electric proportional control (fan drive applications) Normally open on/off electric PC control D PC setting (2 digit code, 1 bar increments) Example 1 = to 26 bar [145 to 377 psi] (25C and 38C) to 21 bar [145 to 345 psi] (3D and 45D) E Load sensing setting (2 digit code, 1 bar increments) Example 2 = 2 bar to 4 bar [174 to 58 psi] NN RP Not applicable (use with PC and RP controls) Must be 2 bar F Not used NN Not applicable G N H Pilot orifice None (standard) Gain orifice 52L519 Rev FJ September 28 27

28 Frames L and K Order code (continued) J K R S P C D E F G H L M N 3 Standard orifice J1 Input shaft C2 13 tooth, 16/32 pitch (ANSI A Class 5) C3 15 tooth, 16/32 pitch (ANSI A Class 5) T1 T2 K1 K2 Ø 25.4 mm [1 in], 1:8 taper Ø mm [.875 in], 1:8 taper Ø mm [.875 in] (short) Ø mm [.875 in] (long) J2 N R A T G B V Auxiliary mounting flange None Running cover SAE-A, 9-tooth output spline SAE-A, 11-tooth output spline SAE-A, 11 tooth rotated 9 degrees SAE-B, 13-tooth output spline SAE-BB, 15-tooth output spline J3 System port size and location Code Location Port type Inlet size Outlet size K Radial 4 bolt split flange 38.1 mm [1.5 in] 25.4 mm [1 in] M Axial 4 bolt split flange 31.8 mm [1.25 in] 25.4 mm [1 in] F Axial O-ring boss 1 7 /8 in. 1 5 /16 in. G Radial O-ring boss 1 7 /8 in. 1 5 /16 in. K1 Shaft seal A Single lip seal, viton K2 Mounting flange and housing port style 6 SAE-B 2-bolt, SAE O-ring boss housing ports K3 Not used N Not applicable L Displacement limiter KNB None PLB AAA M Special hardware NNN None N Special features NNN None Endcap machined and plugged Adjustable, factory set at max angle 28 52L519 Rev FJ September 28

29 Frames L and K Controls Pressure compensated control (PC) Specifications Schematic diagram PC control setting range Model bar psi L25C L3D K38C K45D PC schematic M2 B Response/recovery times* (ms) Response Recovery L25C 3 9 L3D 3 1 K38C 3 15 K45D 3 11 * For definitions, see page 9 Legend B = Outlet S = Inlet L1, L2 = Case drain M2 = System pressure gauge port L2 S L1 P11 98 Specifications Remote PC control (RP) PC control setting range Model bar psi L25C L3D K38C K45D Response/recovery times* (ms) Response Recovery L25C 3 9 L3D 3 1 K38C 3 15 K45D 3 11 * For definitions, see page 1. Schematic diagram Remote PC schematic X LS setting Model bar psi All 2 29 M2 B Legend B = Outlet S = Inlet L1, L2 = Case drain M2 = System pressure gauge port X = Remote PC port L2 S L1 P L519 Rev FJ September 28 29

30 Frames L and K Controls (continued) Specifications Load sensing control (LS) PC setting range Model bar psi L25C L3D K38C K45D Response/recovery times* (ms) Response Recovery L25C 3 7 L3D 3 7 K38C 3 8 K45D 3 8 Schematic diagram LS Schematic X * For definitions, see page 11. LS setting range Model bar psi All M2 L2 B Legend B = Outlet S = Inlet L1, L2 = Case drain M2 = System pressure gauge port X = LS signal port X L1 P Load sensing control with internal bleed orifice (LB) Specifications PC setting range Model bar psi L25C L3D K38C K45D Response/recovery times* (ms) Response Recovery L25C 3 7 L3D 3 7 K38C 3 8 K45D 3 8 Schematic diagram LB Schematic X * For definitions, see page 11. LS setting range Model bar psi All M2 L2 B Legend B = Outlet S = Inlet L1, L2 = Case drain M2 = System pressure gauge port X = LS signal port S L1 P L519 Rev FJ September 28

31 Frames L and K Controls (continued) Specifications Normally closed on/off electric PC control (ED) PC control setting range Model bar psi L25C, K38C L3D, K45D 1-24 bar [ psi] 1-21 bar [ psi] Response/recovery times* (ms) Response Recovery L25C 3 9 L3D 3 1 K38C 3 15 K45D 3 11 * For definitions, see page 11. Schematic diagram ED schematic X LS setting range Model bar psi All M2 B Legend B = Outlet S = Inlet L1, L2 = Case drain M2 = System pressure gauge port X = Remote PC port L2 S L1 P16 44 Normally open on/off electric PC control (AA) Specifications PC control setting range Model bar psi L25C, K38C, L3D, K45D 1-21 bar [ psi] Response/recovery times* (ms) Response Recovery L25C 3 9 L3D 3 1 K38C 3 15 K45D 3 11 * For definitions, see page 11. Schematic diagram AA schematic X LS setting range Model bar psi All M2 L2 B Legend B = Outlet S = Inlet L1, L2 = Case drain M2 = System pressure gauge port X = Remote PC port S L1 P16 49 Evaluate the system to decide if normally open on/off (failsafe) control is necessary. 52L519 Rev FJ September 28 31

32 Frames L and K Controls (continued) Specifications Electric proportional control (EJ) (Normally closed) PC control setting range Model bar psi L25C, K38C L3D, K45D 1-26 bar bar LS setting range Model bar psi All Schematic diagram EJ schematic X Legend B = Outlet S = Inlet L1, L2 = Case drain M2 = System pressure gauge port X = Remote PC port B M2 L2 S L1 P16 687E 32 52L519 Rev FJ September 28

33 Frames L and K Input shafts Code C2 Description 13 tooth spline 16/32 pitch (ANSI A Class 5) Maximum torque rating¹ N m [lbf in] 288 [2546] Drawing Ø18.82 [.74] MAX Ø21.72 ±.9 [.855 ±.4] 13 TOOTH 16/32 PITCH 3 PRESSURE ANGLE [.813] PITCH DIA FILLET ROOT SIDE FIT COMPATIBLE WITH ANSI B CLASS 5 ALSO MATES WITH FLAT ROOT SIDE FIT 8 ±.475 [.31 ±.2] 15.2 ±.5 [.6 ±.2] COUPLING MUST NOT PROTRUDE BEYOND THIS POINT 33 [1.3] P11 993E C3 15 tooth spline 16/32 pitch (ANSI A Class 5) 44 [3575] 15 TOOTH 16/32 PITCH 3 PRESSURE ANGLE [.938] PITCH DIA FILLET ROOT SIDE FIT CLASS 5 ALSO MATES WITH FLAT ROOT SIDE FIT Ø21.92 MAX [.863] Ø25.27 ±.12 [.995 ±.5] 8±.475 [.31 ±.2] COUPLING MUST NOT PROTRUDE BEYOND THIS POINT ±.5 [.92 ±.2] 38 [1.5] P11 994E T1 Ø 25.4 mm [1 in] 1:8 taper (SAE J51) 362 [32] [1 ] REF [2.75] [1.6] [ ] [ ] WOODRUFF KE Y Ø22.22 GA UGE [.87] 3/4-16UNF-2A THD 8 ±.8 [.31 ±.3] 34.92±.63 [1.375 ±.25] 125 TAPER PER METER COMPATIBLE WITH SAE J [1] NOMINAL SHAFT DIAMETER 9.42 ±.3 [.37 ±.1] GA UGE C OUPLING MUST NO T PR OT RUDE BEY OND THIS POINT P11 996E 1. See Input shaft torque ratings, page 18 for an explanation of maximum torque. 52L519 Rev FJ September 28 33

34 Frames L and K input shafts (continued) Code T2 Description Ø mm [.875 in] 1:8 taper (SAE J51) Maximum torque rating¹ N m [lbf in] 35 [27] Drawing REF [2.35] 23.1 [.91] [ ] [ ] WOODRUFF KE Y Ø22.22 [.875] Ø19.5 [.75] GA UGE 5/8-18 UNF 2A THD 8 ±.3 [.31 ±.3] 28.68±.63 [1.129 ±.25] 125 TAPER PER METER COMPATIBLE WITH SAE J [.874] NOMINAL SHAFT DIAMETER 3.18±.3 [.13 ±.1] GA UGE C OUPLING MUST NO T PR OT RUDE BEY OND THIS POINT P11 995E K1 Ø mm [.875 in] 33 mm [1.3 in] 35 [27] 6.35 [.25] x 12.7 [.5] LONG SQUARE KEY [ ] Ø22.2 ±.25 [.874 ±.1] 8±.8 [.31 ±.3] K2 Ø mm [.875 in] 63 mm [2.48 in] long 35 [27] COUPLING MUST NOT PROTRUDE BEYOND THIS POINT 33 [1.3] P11 997E 6.35 [.25] x 38.1 [1.5] L ONG SQU ARE KE Y [ ] Ø22.2 ±.25 [.874 ±.1] 8 ±.3 [.315 ±.35] CO UPLING MUST NO T PR OT RUDE BEY OND THIS POINT 63 [2.48] P11 998E 1. See Input shaft torque ratings, page 18 for an explanation of maximum torque L519 Rev FJ September 28

35 Frames L and K Auxiliary mounting pads See page 18 for mating pump pilot and spline dimensions. SAE-A auxiliary mounting pad Dimensions 8 ±.8 [.32 ±.3] PER SAE J [8.997] MOUNTIN G FLANGE 3/8-16UNC-2BTHD 17.8 [.7] MI N THD DEPTH R.51 MA X [.2] Ø88.62 [3.49] Ø [ ] 16.4 [4.19] Specifications Coupling 9-tooth 11-tooth 53.2 [2.9] Spline minimum 12.6 mm [.5 in] 13.5 mm [.53 in] engagement Maximum torque 17 N m [95 lbf in] 147 N m [13 lbf in] O-RING SEAL REQUIRED REF [3.237] I.D.X 2.62 [.13] CROSS SECTION P/N [.8] 8.1 ±.7 [.319 ±.28] [2.35] MIN SHAF T CLEARANC E P11999E C OUPLING-SAE A: SPLINE: 11 TO OT H 16/32 PIT CH 3 PRESSURE ANGLE [.6875] PIT CH DI A FILLET RO OT SIDE FIT PER SAE B , CLASS 6 C OUPLING-SAE A: SPLINE: 9T OO TH 16/32 PIT CH 3 PRESSURE ANGL E [.5625] PIT CH DI A FILLET RO OT SIDE FIT PER ANSI B , CLASS 6 See page 18 for mating pump pilot and spline dimensions. SAE-B auxiliary mounting pad Dimensions 8 ±. 8 [.31 ±.3] PER SAE J [8.82] MOUNTIN G FLANGE 1/2-13UNC-2BTHD 19.7 [.76] MI N THD DEPTH R2 MA X [.8] Ø15.64 [4.159] Ø [ ] 146 [5.75] 73 [2.87] Specifications Coupling 13-tooth 15-tooth Spline minimum 13.2 mm [.52 in] 16.1 mm [.63 in] engagement Maximum torque 171 N m [1512 lbf in] 171 N m [1512 lbf in] O-RING SEAL REQUIRED REF [3.989] I.D.X 1.78 [.7] CROSS SECTIO N P/N MIN SHAF T CLEARANC E 1. 3 [.5] 11 ±.13 [.43±.1] [2.18] C OUPLING-SAE B SPLINE: 13 TO OT H 16/32 PIT CH 3 PRESSURE ANGLE [.8125] PIT CH DI A FILLET RO OT SIDE FIT PER ANSI B CLASS 6 C OUPLING-SAE B-B SPLINE: 15 TO OT H 16/32 PIT CH 3 PRESSURE ANGL E [.9375] PIT CH DI A FILLET RO OT SIDE FIT PER ANSI B CLASS 6 P14E 52L519 Rev FJ September 28 35

36 Frames L and K Auxilliary mounting pads (continued) Mounting pads at 9 degrees P16 76E P16 644E SAE-A Auxilliary Pad Special SAE-A 11 tooth Running cover Dimensions [8.37] P16 77E 36 52L519 Rev FJ September 28

37 Frames L and K Displacement limiter L and K Frame open circuit pumps are available with an optional adjustable displacement limiter. This adjustable stop limits the pump s maximum displacement. Setting range L25C to 25 cm³ [ to 1.53 in³] L3D K38C to 3 cm³ [ to 1.83 in³] to 38 cm³ [ to 2.32 in³] Displacement limiter cross-section K45D to 45 cm³ [ to 2.75 in³] P14 84 Displacement per turn L25C 1.2 cm³/rev [.7 in³/rev] L3D K38C K45D 1.43 cm³/rev [.9 in³/rev] 1.81 cm³/rev [.11 in³/rev] 2.15 cm³/rev [.13 in³/rev] 52L519 Rev FJ September 28 37

38 Frames L and K Installation drawings Ø25.4 [1] OUTLET SYSTEM PORT B 345 BAR [5] PSI] SPLIT FLANGE BOSS PER ISO 6162 SAE J518 CODE 61 with 3/8-16 UNC X 2 [.787] MIN THD SYSTEM PORT S (INLET) [2.62] SERVO PRESSURE GAGE PORT ISO SAE J1926/1 3/ [1.31] 33 [1.3] 33 [1.3] 33 [1.3] Clockwise rotation Axial ported endcap [2.312] 3.18 [1.188] 33 [1.3] Split flange axial ports - counterclockwise rotation SYSTEM PORT B (OUTLET) ISO ISO SAE J1926/1 SAE J1926/1 1 7/ /16-12 Ø31.8 [1.25] INLET SYSTEM PORT S 276 BAR [4] PSI] SPLIT FLANGE BOSS PER ISO 6162 SAE J518 CODE 61 with 7/16-14 UNC X 17 [.669] MIN THD LS STANDBY PRESSURE ADJUSTMENT PC PRESSURE ADJUSTMENT SYSTEM PRESSURE GAGE PORT M2 ISO SAE J1926/1 9/16-18 or M14x1.5-6H LS SIGNAL PORT X ISO SAE J1926/1 7/ [6.11] [5.29] 62 [2.44] 7.4 [2.77] 37 [1.46] M [8.79] [7.18] [6.6] [7.16] 15.8 [4.16] 8 [3.15] [6.8] SYSTEM PORTS S & B SPOTFACE DEPTH 67.7 [2.67] 67.7 [2.67] 15 [.59] CASE DRAIN PORT L1 ISO SAE J1926/1 7/8-14 R1 MAX [.4] Ø ±.25 [3.999 ±.1] 9.4 [.37] CASE DRAIN PORT L2 SPOTFACE DEPTH CASE DRAIN PORT L1 SPOTFACE DEPTH SERVO PRESSURE GAGE PORT ISO SAE J1926/1 3/ [6.89] SYSTEM PORT B (OUTLET) ISO ISO SAE J1926/1 SAE J1926/1 1 5/ / [1.3] 33 [1.3] SYSTEM PORT S (INLET) P1617E Counterclockwise rotation Third-angle projection mm [in] 38 52L519 Rev FJ September 28

39 Frames L and K Installation drawings (continued) Axial ported endcap (continued) 99 [3.9] 6.7 [.26] 97.4 [3.83] APPROXIMATE CENTER OF GRAVITY [4.8] 132 [5.2] APPROXIMATE CENTER OF GRAVITY Ø14.3 [.563] 2X CW CCW 32 [1.26] 73 [2.87] 146 [5.75] Split flange axial endcap (counterclockwise rotation shown) 8 [3.15] CASE DRAIN PORT L2 ISO SAE J1926/1 7/ [1.2] 222 [8.74] 83.3 [3.28] Adjustable displacement limiter P1464E Third-angle projection mm [in] 52L519 Rev FJ September 28 39

40 Frames L and K Installation drawings (continued) Radial ported endcap 27.9 [8.19] 9.5 [3.56] 67.7 [2.67] CASE DRAIN PORT L2 SPOTFACE DEPTH SYSTEM PRESSURE GAGE PORT M2 ISO SAE J1926/1 9/ [.59] 67.7 [2.67] CASE DRAIN PORT L1 SPOTFACE DEPTH 27 [8.15] 95 [3.74] 95 [3.74] 8 [3.15] CASE DRAIN PORT L1 ISO SAE J1926/1 7/8-14 R1 MAX [.4] 37 [1.46] 62 [2.44] B Ø11.57 ±.25 [3.999 ±.1] 94.5 [3.72] SYSTEM PORT S SPOTFACE DEPTH 94.5 [3.72] Clockwise rotation 95 [3.74] SYSTEM PORT B SPOTFACE DEPTH 95 [3.74] SYSTEM PORT B (OUTLET) ISO SAE J1926/1 1 5/ [6.54] 9.4 [.37] 94.5 [3.72] SYSTEM PORT B SPOTFACE DEPTH 94.5 [3.72] SYSTEM PORT S SPOTFACE DEPTH P16 171E Counterclockwise rotation Third-angle projection mm [in] 4 52L519 Rev FJ September 28

41 Frames L and K Installation drawings (continued) Radial ported endcap (continued) Ø25.4 [1] OUTLET SYSTEM PORT B 345 BAR [5] PSI] SPLIT FLANGE BOSS PER ISO 6162 SAE J518 CODE 61 with 3/8-16 UNC X 2 [.787] MIN THD Ø38.1 [1.5] INLET SYSTEM PORT S 27 BAR [3] PSI] SPLIT FLANGE BOSS PER ISO 6162 SAE J518 CODE 61 with 1/2-13 UNC X 27 [1.63] MIN THD [2.62] [2.753] 166 [6.54] [1.31] [1.411] 166 [6.54] 99 [3.9] LS SIGNAL PORT X SPOTFACE DEPTH Split flange radial endcap (counterclockwise rotation shown) 4.4 [.17] 146 [5.75] [4.44] 132 [5.2] [4.8] LS STANDBY PRESSURE ADJUSTMENT PC PRESSURE ADJUSTMENT [5.29] APPROXIMATE CENTER OF GRAVITY [6.11] Ø14.3 [.563] 2X CW 73 [2.87] 146 [5.75] CCW APPROXIMATE CENTER OF GRAVITY 32 [1.26] 8 [3.15] 166 [6.54] 2.7 [.81] SYSTEM PORT S (INLET) ISO SAE J1926/1 1 7/8-12 CASE DRAIN PORT L2 ISO SAE J1926/1 7/ [8.74] 83.3 [3.28] P14 65E Adjustable displacement limiter Third-angle projection mm [in] 52L519 Rev FJ September 28 41

42 Frames L and K Installation drawings (continued) Electric on/off control 16.9 [.67] 9.5 [.375] Electric solenoid control assembly (right side) [7.79] 7.8 [.31] Deutsch type (2) pin connector [6.43] [5.69] 2.9 [.11] [4.56] 7.8 [.31] Electric solenoid control assembly (left side) 9.5 [.375] 16.9 [.67] Deutsch type (2) pin connector [6.42] P16 19E Third-angle projection mm [in] 42 52L519 Rev FJ September 28

43 Frame J Design Series 45 Frame J pumps have a single servo piston design with a cradle-type swashplate set in polymer-coated journal bearings. A bias spring and internal forces increase swashplate angle. The servo piston decreases swashplate angle. Nine reciprocating pistons displace fluid from the pump inlet to the pump outlet as the cylinder block rotates on the pump input shaft. The block spring holds the piston slippers to the swashplate via the slipper retainer. The cylinder block rides on a bi-metal valve plate optimized for high volumetric efficiency and low noise. Tapered roller bearings support the input shaft and a viton lip-seal protects against shaft leaks. An adjustable one spool (PC only, not shown) or two spool (LS and PC) control senses system pressure and load pressure (LS controls). The control ports system pressure to the servo piston to control pump output flow. Frame J cross section LS control (attached to endcap) LS spool LS adjustment PC spool PC adjustment LS control Servo piston Bias spring Piston Slipper Tapered roller bearing Valve plate Cylinder block spring Shaft seal Tapered roller bearing Input shaft Cylinder block Slipper retainer Swashplate P14 24E 52L519 Rev FJ September 28 43

44 Frame J Specifications Features and options Model For general operating parameters, including fluid viscosity, temperature, and inlet and case pressures, see page 13. For system design parameters, including installation, filtration, reservoir, and line velocities, see page 15. Feature Unit J45B J51B J6B J65C J75C Maximum Displacement cm³ [in³] 45 [2.75] 51 [3.11] 6 [3.66] 65 [3.97] 75 [4.58] Flow at rated speed (theoretical) Input torque at maximum displacement (theoretical) Mass moment of inertia of internal rotating components l/min [US gal/min] N m/bar [lbf in/1 psi] kg m² [slug ft²] 126. [33.3].716 [436.9].455 [.336] [36.4].811 [495.1].455 [.336] 156. [41.2].956 [583.6].455 [.336] [42.9] 1.35 [631.4].433 [.319] Weight Axial ports kg [lb] [51] Radial ports [58.8] Rotation Clockwise, Counterclockwise Mounting Auxiliary mounting (See page 58) System ports (type) System ports (location) Control types (See page 52) 2 bolt SAE-B and SAE-C, 4 bolt SAE-C SAE-A, SAE-B, SAE-BB, SAE-C SAE O-ring boss. 4-bolt split flange Axial, Radial 18. [47.5] [728.1].433 [.319] AG, AF, PC, Remote PC, LS, LS with internal bleed Shafts (See page 55) Splined 13 tooth, 14 tooth, 15 tooth Displacement limiters Tapered Straight Ø mm [1.25 in], 1:8 taper Ø mm [1.25 in] Optional, adjustable For definitions of pressure and speed ratings, see page 14. For more information on external shaft loads, see page 16; mounting flange loads, see page 17. Ratings Model Rating Units J45B J51B J6B J65C J75C Input speed¹ minimum min -1 (rpm) Working pressure External shaft loads continuous maximum continuous bar [psi] 31 [4495] 31 [4495] 31 [4495] 26 [377] 26 [377] maximum 4 [58] 4 [58] 4 [58] 35 [575] 35 [575] External moment (M e ) N m [lbf in] 226 [2] 226 [2] 226 [2] 226 [2] 226 [2] Thrust in (T in ), out (T out ) N [lbf ] 22 [495] 22 [495] 22 [495] 22 [495] 22 [495] Bearing life at 14 bar [23 psi] B 1 hours Mounting flange load moments at 21 bar [345 psi] at 26 bar [377 psi] at 31 bar [4495 psi] Vibratory (continuous) N m [lbf in] SAE-C: 15 [14 ], SAE-B: 735 [65] Shock (max) SAE-C: 56 [5 ], SAE-B: 26 [23 ] 1. Continuous input speeds are valid at 1 bar absolute [ in Hg vac] inlet pressure. Maximum input speeds require changing the inlet pressure or reducing pump displacement. See Inlet pressure vs. speed charts. For more information on noise levels, see page 19. Sound levels² db(a) 21 bar [345 psi] 26 bar [377 psi] 31 bar [4495 psi] Model 18 min -1 (rpm) Rated speed 18 min -1 (rpm) Rated speed 18 min -1 (rpm) Rated speed J45B J51B J6B J65C J75C Sound data was collected in a semi-anechoic chamber. Values have been adjusted (-3 db) to reflect anechoic levels L519 Rev FJ September 28

45 Frame J Performance J45B Flow vs. speed 15 Flow and power data valid at 49 C [12 F] and viscosity of 17.8 mm²/sec [88 SUS]. Flow (l/min) Flow (US gal/min) Speed min (rpm) P14 26E Input power vs. speed Power (kw) bar [4495 psi] 26 bar [377 psi] 14 bar [23 psi] Power (hp) The chart on the right shows allowable inlet pressure and speed at various displacements. Greater speeds and lower inlet pressures are possible at reduced displacement. Operating outside of acceptable limits reduces pump life. Inlet pressure vs. speed Inlet Pressure (bar abs) Speed min (rpm) Shaft Speed min (rpm) P14 25E 1% 9% 8% (psi gauge) (in Hg vac) P14 27E 52L519 Rev FJ September 28 45

46 Frame J Performance J51B Flow and power data valid at 49 C [12 F] and viscosity of 17.8 mm²/sec [88 SUS]. Flow vs. speed Flow (l/min) Flow (US gal/min) Speed min (rpm) P14 29E Input power vs. speed Power (kw) bar [4495 psi] 26 bar [377 psi] 14 bar [23 psi] Power (hp) The chart on the right shows allowable inlet pressure and speed at various displacements. Greater speeds and lower inlet pressures are possible at reduced displacement. Operating outside of acceptable limits reduces pump life. Inlet pressure vs. speed Inlet Pressure (bar abs) Speed min (rpm) P14 28E 1% 9% 8% Shaft Speed min (rpm) (psi gauge) (in Hg vac) P14 21E 46 52L519 Rev FJ September 28

47 Frame J Performance J6B Flow and power data valid at 49 C [12 F] and viscosity of 17.8 mm²/sec [88 SUS]. Flow vs. speed Flow (l/min) Flow (US gal/min) Speed min (rpm) P14 212E Input power vs. speed Power (kw) bar [4495 psi] 26 bar [377 psi] 14 bar [23 psi] Power (hp) Speed min (rpm) P14 211E The chart on the right shows allowable inlet pressure and speed at various displacements. Greater speeds and lower inlet pressures are possible at reduced displacement. Operating outside of acceptable limits reduces pump life. Inlet pressure vs. speed Inlet Pressure (bar abs) % 9% 8% Shaft Speed min (rpm) (psi gauge) (in Hg vac) P14 213E 52L519 Rev FJ September 28 47

48 Frame J Performance J65C Flow and power data valid at 49 C [12 F] and viscosity of 17.8 mm²/sec [88 SUS]. Flow vs. speed Flow (l/min) Speed min (rpm) P14 215E Flow (US gal/min) Input power vs. speed Power (kw) bar [377 psi] 21 bar [345 psi] 14 bar [23 psi] Power (hp) Speed min (rpm) P14 214E The chart on the right shows allowable inlet pressure and speed at various displacements. Greater speeds and lower inlet pressures are possible at reduced displacement. Operating outside of acceptable limits reduces pump life. Inlet pressure vs. speed Inlet Pressure (bar abs) % 9% 8% Shaft Speed min (rpm) (psi gauge) (in Hg vac) P14 216E 48 52L519 Rev FJ September 28

49 Frame J Performance J75C Flow and power data valid at 49 C [12 F] and viscosity of 17.8 mm²/sec [88 SUS]. Flow vs. speed Flow (l/min) Flow (US gal/min) Speed min (rpm) P14 218E Input power vs. speed Power (kw) bar [377 psi] 21 bar [345 psi] 14 bar [23 psi] Power (hp) The chart on the right shows allowable inlet pressure and speed at various displacements. Greater speeds and lower inlet pressures are possible at reduced displacement. Operating outside of acceptable limits reduces pump life. Inlet pressure vs. speed Inlet Pressure (bar abs) Speed min (rpm) P14 217E 1% 9% 8% Shaft Speed min (rpm) (psi gauge) (in Hg vac) P14 219E 52L519 Rev FJ September 28 49

50 Series 45 Axial Piston Open Circuit Pumps Frame J Order code J K R S P C D E F G H L M N R JR S L R Product J Frame, variable displacement open circuit pump Rotation Left hand (counterclockwise) Right hand (clockwise) P Displacement and pressure rating 45B 45 cm³/rev [2.75 in³/rev], 31 bar [4495 psi] continuous working pressure 51B 6B 65C 75C 51 cm³/rev [3.11 in³/rev], 31 bar [4495 psi] continuous working pressure 6 cm³/rev [3.66 in³/rev], 31 bar [4495 psi] continuous working pressure 65 cm³/rev [3.97 in³/rev], 26 bar [377 psi] continuous working pressure 75 cm³/rev [4.58 in³/rev], 26 bar [377 psi] continuous working pressure C Control type PC Pressure compensated control 1-28 bar [ psi] BC* RP BP* LS BS* LB BB* AG AF Pressure compensated control bar [ psi] Remote pressure compensated control 1-28 bar [ psi] Remote pressure compensated control bar [ psi] Load sensing / pressure compensating control 1-28 bar [ psi] Load sensing / pressure compensating control bar [ psi] Load sensing / pressure compensating control with internal bleed orifice 1-28 bar [ psi] Load sensing / pressure compensating control with internal bleed orifice bar [ psi] Pressure compensated control with electric on/off solenoid operated 2-way valve (normally closed) Pressure compensated control with electric on/off solenoid operated 2-way valve (normally open) * Use only with 45, 51, and 6 cm³ displacements. D PC setting (2 digit code, 1 bar increments) Example 1 = 1 bar to 26 bar [145 to 377 psi] (65C and 75C) to 31 bar [145 to 4495 psi] (45B, 51B and 6B) E Load sensing setting (2 digit code, 1 bar increments) Example 2 = 2 bar to 4 bar [145 to 58 psi] NN RP and BP Not applicable (use with PC controls) Must be 2 bar F Not used NN Not applicable G N Pilot orifice None (standard) H Gain orifice 3 Standard orifice 5 52L519 Rev FJ September 28

51 Frame J Order code (continued) J K R S P C D E F G H L M N J1 Input shaft C2 13 tooth, 16/32 pitch (ANSI A Class 5) C3 15 tooth, 16/32 pitch (ANSI A Class 5) S1 14 tooth, 12/24 pitch (ANSI A Class 5) K4 TO Ø mm [1.25 in] straight key Ø mm [1.25 in], 1:8 taper J2 N A B C T V R G Auxiliary mounting flange type and coupling None (Use with axial ported endcap options 3 and 4 below) SAE-A, 9-tooth output spline SAE-B, 13-tooth output spline SAE-C, 14-tooth output spline SAE-A, 11-tooth output spline SAE-BB, 15-tooth output spline Running cover (Radial ported endcap machined for aux. pad. Pad and coupling sold separately.) Special SAE-A, 11 tooth, rotated 9 degrees J3 Endcap option (system port size and location) Code Port location Port type Inlet size Outlet size 2 Radial 4-bolt split flange 5.8 mm [2. in] 25.4 mm [1. in] 3 Axial O-ring boss 1 7 /8 in. 1 5 /16 in. 4 Axial 4-bolt split flange 5.8 mm [2. in] 25.4 mm [1. in] V * Radial 4-bolt split flange 5.8 mm [2. in] 25.4 mm [1. in] W ** Axial 4-bolt split flange 5.8 mm [2. in] 25.4 mm [1. in] * must have auxilliary mounting flange or runnung cover ** must have displacement limiter FFF K1 Shaft seal A Single lip seal, viton K2 Mounting flange and housing port style 2 SAE-C 4-bolt, SAE O-ring boss housing ports 8 SAE-B 2-bolt, SAE O-ring boss housing ports 9 SAE-C 2-bolt, SAE O-ring boss housing ports K3 Not used N Not applicable L Displacement limiter NNN None FFF * Adjustable, factory set at maximum angle * can only be used with V and W endcap options M Special hardware NNN None N Special features NNN None 52L519 Rev FJ September 28 51

52 Frame J Controls Specifications Pressure compensated control (PC, BC) PC control setting range Model PC BC J45B, J51B, J6B J65C, J75C 1-28 bar [ psi] 1-26 bar [ bar] bar [ psi] N/A Response/recovery times* (ms) Response Recovery J45B J51B J6B J65B J75B * For definitions, see page 9. Schematic diagram PC schematic M1 B Legend B = Outlet S = Inlet L1, L2 = Case drain M1* = System pressure gauge port * M1 port is available on axially ported endcaps only Specifications L2 S L1 P14 22 Remote PC control (RP, BP) PC control setting range Model RP BP J45B, J51B, J6B J65C, J75C 1-28 bar [ psi] 1-26 bar [ bar] bar [ psi] N/A Response/recovery times* (ms) Response Recovery J45B J51B J6B J65B J75B * For definitions, see page 1 Schematic diagram Remote PC schematic X LS setting Model bar psi All 2 29 M1 B X Legend B = Outlet S = Inlet L1, L2 = Case drain X = Remote PC port M1* = System pressure gauge port * M1 port is available on axially ported endcaps only L2 S L1 P Attach remote PC valve at port X. Size the external valve and plumbing for a pilot flow of 3.8 l/min [1 US gal/min] L519 Rev FJ September 28

53 Frame J Controls (continued) Specifications Load sensing control (LS, BS) PC control setting range Code LS BS J45B, J51B, J6B J65C, J75C 1-28 bar [ psi] 1-26 bar [ bar] bar [ psi] N/A Response/recovery times* (MS) J45B J51B J6B J65B J75B Response Recovery * For definitions, see page 11. Schematic diagram LS Schematic X LS setting range Model bar psi All X M1 L2 B Legend B = Outlet S = Inlet L1, L2 = Case drain X = LS signal port M1* = System pressure gauge port * M1 port is available on axially ported endcaps only S L1 P Load sensing control with internal bleed orifice (LB, BB) Specifications PC control setting range Code LB BB J45B, J51B, J6B J65C, J75C 1-28 bar [ psi] 1-26 bar [ bar] bar [ psi] N/A Response/recovery times* (MS) J45B J51B J6B J65B J75B Response Recovery * For definitions, see page 11. Schematic diagram LSBSchematic X LS setting range Model bar psi All X M1 L2 B Legend B = Outlet S = Inlet L1, L2 = Case drain X = LS signal port M1* = System pressure gauge port * M1 port is available on axially ported endcaps only S L1 P L519 Rev FJ September 28 53

54 Frame J Controls (continued) Specifications Normally closed on/off electric PC control (AG) PC control setting range Code AG J45B, J51B, J6B J65C, J75C 1-28 bar [ psi] 1-26 bar [ bar] Response/recovery times* (ms) J45B J51B J6B J65B J75B Response Recovery * For definitions, see page 12. Schematic diagram AG schematic X LS setting range Model bar psi All M1 L2 B S L1 P16 656E Legend B = Outlet S = Inlet L1, L2 = Case drain X = Remote PC port M1* = System pressure gauge port * M1 port is available on axially ported endcaps only Normally open on/off electric PC control (AF) Specifications AF control setting range Code AF J45B, J51B, J6B J65C, J75C 1-28 bar [ psi] 1-26 bar [ bar] Response/recovery times* (ms) J45B J51B J6B J65B J75B Response Recovery * For definitions, see page 12. Schematic diagram AF schematic X LS setting range Model bar psi All M1 L2 B S L1 P16 657E Legend B = Outlet S = Inlet L1, L2 = Case drain X = Remote PC port M1* = System pressure gauge port * M1 port is available on axially ported endcaps only Evaluate your system to decide if normally open or normally closed control override is required for failsafe operation L519 Rev FJ September 28

55 Frame J Input shafts Code C2 Description 13 tooth spline 16/32 pitch (ANSI A Class 5) For use with SAE-B Maximum torque rating¹ N m [lbf in] 288 [2546] Drawing 13 TOOTH 16/32 PITCH 3 PRESSURE ANGLE [.813] PITCH DIA FILLET ROOT SIDE FIT COMPATIBLE WITH ANSI B CLASS 5 ALSO MATES WITH FLAT ROOT SIDE FIT Ø18.63 MAX [.733] Ø21.72 ±.9 [.855 ±.4] 15.2 ±.5 [.6 ±.2] 8±.8 [.31 ±.3] COUPLING MUST NOT PROTRUDE BEYOND THIS POINT 33 [1.3] P14 224E C3 15 tooth spline 16/32 pitch (ANSI A Class 5) For use with SAE-B 44 [3575] 15 TOOTH 16/32 PITCH 3 PRESSURE ANGLE [.938] PITCH DIA FILLET ROOT SIDE FIT COMPATIBLE WITH ANSI B CLASS 5 ALSO MATES WITH FLAT ROOT SIDE FIT Ø21.96 MAX [.864] ±.13 [.995 ±.5] ±.5 [.88 ±.2] 8±.8 [.31 ±.3] 38 [1.5] COUPLING MUST NOT PROTRUDE BEYOND THIS POINT P14 225E 1. See Input shaft torque ratings, page 18 for an explanation of maximum torque. 52L519 Rev FJ September 28 55

56 Frame J input shafts (continued) Code Description Maximum torque rating¹ N m [lbf in] Drawing S1 14 tooth spline 12/24 pitch (ANSI A Class 5) For use with SAE-C 734 [6495] 47.6 [1.87] Ø25.5 MAX [1] 14 TOOTH 12/24 PITCH 3 PRESSURE ANGLE [1.167] PITCH FILLET ROOT SIDE FIT COMPATIBLE WITH ANSI B CLASS 5 ALSO MATES WITH FLAT ROOT SIDE FIT Ø31.14 ±.8 [1.226 ±.3] 28 ±.5 [1.1 ±.2] COUPLING MUST NOT PROTRUDE BETOND THIS POINT 8±.8 [.31 ±.3] P14 226E K4 Ø mm [1.25 in] straight key 655 [5797] 56 [2.2] For use with SAE-C 48.3±.43 [1.89]± [.313] X [1.125] LONG SQUARE KEY 35.2 ±.13 [1.39 ±.1] Ø31.72 ±.25 [1.249 ±.1] 8±.8 [.31 ±.3] COUPLING MUST NOT PROTRUDE BETOND THIS POINT P14 227E 1. See Input shaft torque ratings, page 18 for an explanation of maximum torque L519 Rev FJ September 28

57 Frame J input shafts (continued) Code TO Description Ø mm [1.25 in] 1:8 taper For use with SAE-C Maximum torque rating¹ N m [lbf in] 734 [6495] Drawing [1.69] ±.25 [1.219]± [.315] - + X Dia [1.25] -.25 WOODRUFF KEY 1.-2 UNF-2A THD ±. 3 [.88 ±.1] GA UGE Ø [1.19] GA UGE 125 TAPER PER METER COMPATIBLE WITH SAE J [1.25] NOMINAL SHAFT DIAMETER C OUPLING MUST NO T PR OT RUDE BEY OND THIS POINT P14 228E 8±. 8 [.31 ±.3] 1. See Input shaft torque ratings, page 18 for an explanation of maximum torque. 52L519 Rev FJ September 28 57

58 Frame J Auxiliary mounting pads See page 18 for mating pump pilot and spline dimensions. SAE-A auxiliary mounting pad (non-integral) Dimensions 3 [.12] APPR OX IM AT E CENTER OF GR AV IT Y 23 [.91] APPR OX IM AT E CENTER OF GR AV IT Y [1.41] [5.4] MOUNTING FLANGE 9.8 [.39] 3/8-16 UNC-2B THD 17.8 [.7] MI N FULL THD DEPTH 2X Ø88.62 [3.49] Ø [ ] R1.2 MA X [2.9] [4.19] Specifications Coupling 9-tooth 11-tooth Spline minimum 13.5 mm [.53 in] 15 mm [.59 in] engagement Maximum torque 17 N m [95 lbf in] 147 N m [13 lbf in] O-RING SEAL REQUIRED REF [3.23] I.D x 2.62 [.13] CROSS SECTION P/N [.8] 8.1 [.32] 59.4 [2.34] P14 23E A C OUPLING-SAE A SPLINE: 9T OO TH 16/32 PI TC H 3 PRESSURE ANGLE [.5625] PIT CH DI A FILLET RO OT SIDE FI T PER ANSI B CLASS 6 T C OUPLING-SAE A SPLINE: 11 TO OT H 16/32 PI TC H 3 PRESSURE ANGLE [.6875] PIT CH DI A FILLET RO OT SIDE FI T PER ANSI B CLASS 6 See page 18 for mating pump pilot and spline dimensions. SAE-B auxiliary mounting pad Dimensions 1/2-13UNC-2B TH D 19.7 [.76] MI N THD DEPTH 2X 3.1 [.122] APPRO XIM AT E CENTER OF GRA VIT Y 22 [.87] APPRO XIM AT E CENTER OF GRA VIT Y Ø15.64 [4.159] 26.5 [1.24] [5.4] MOUNTIN G FLANGE 9.8 [.39] R2. MA X [.8] Ø [4.2 - ] 73 [2.87] 146 [5.75] Specifications Coupling 13-tooth 15-tooth Spline minimum 14.2 mm [.56 in] 18.9 mm [.74 in] engagement Maximum torque 249 N m [22 lbf in] 339 N m [3 lbf in] O-RING SEAL REQUIRED REF [3.989] I.D.X 1.78 [.7] CROSS SECTION P/N [.5] 11 ±.12 [.433 ±.5] 55 [2.17] MIN SHAFT CLEARANCE B C OUPLING-SAE B P14 231E SPLINE: 13 TO OT H 16/32 PIT CH 3 PRESSURE ANGL E [.8125] PIT CH DI A FILLET RO OT SIDE FIT PER ANSI B CLASS 6 V C OUPLING-SAE B-B SPLINE: 15 TO OT H 16/32 PIT CH 3 PRESSURE ANGL E [.9375] PIT CH DI A FILLET RO OT SIDE FIT PER ANSI B CLASS L519 Rev FJ September 28

59 Frame J Displacement limiter J Frame open circuit pumps are available with an optional adjustable displacement limiter. This adjustable stop limits the pump s maximum displacement. Setting range J45B 8.4 to 45 cm³ [.51 to 2.75 in³] J51B J6B J65B J75B 13.7 to 51 cm³ [.84 to 3.11 in³] 16.8 to 6 cm³ [1.3 to 3.66 in³] 25.4 to 65 cm³ [1.55 to 3.97 in³] 28.4 to 75 cm³ [1.73 to 4.58 in³] Displacement per turn J45B 6.2 cm³/rev [.38 in³/rev] J51B J6B J65B J75B 6.2 cm³/rev [.38 in³/rev] 6.2 cm³/rev [.38 in³/rev] 7.2 cm³/rev [.44 in³/rev] 7.2 cm³/rev [.44 in³/rev] Displacement limiter cross-section P16 727E Displacement limiters are only available for endcap options V and W. 52L519 Rev FJ September 28 59

60 Frame J Auxiliary mounting pads (continued) See page 18 for mating pump pilot and spline dimensions. SAE-C auxiliary mounting pad Dimensions 1/2-13 UNC-2B TH D 22.7 [.89] MI N THREAD DEPTH 4X 2.9 [.114] APPRO XIM AT E CENTER OF GRA VIT Y 11 [.43] APPRO XIM AT E CENTER OF GRA VIT Y [1.36] [5.5] MOUNTIN G FLANGE [4.51] 57.3 [2.26] 9.7 [.38] Ø [5.18] Ø [5.1- ] Specifications Coupling Spline minimum engagement Maximum torque 14-tooth 18.3 mm [.72 in] 339 N m [3 lbf in] 57.3 [2.26] [4.51] O-RING SEAL REQUIRED REF [4.989] I.D. x 1.78 [.7] CROSS SECTION P/N [.5] 14 [.55] 58. [2.28] MIN SHAFT CLEARANCE C C OUPLING-SAE C P14 232E SPLINE: 14 TO OT H 12/24 PIT CH 3 PRESSURE ANGL E [1.1667] PIT CH DI A FILLET RO OT SIDE FIT PER ANSI B CLASS 6 Running cover [9.86] Endcap and shaft machined to accommodate auxiliary mounting pads; pad and coupling not included. Conversion kits are available for installation in the field. MOUNTING FLANGE P14 233E 6 52L519 Rev FJ September 28

61 Frame J Installation drawings Axial ported endcap [1.33] LS SIGNAL PORT X ISO SAE J1926/1 7/ [1.14] BO TH SIDES [9.7] BO TH SIDES 83.4 [3.28] [2.88] 47 [1.85] 82.1 SY STEM PRESSURE [3.2] GA UGE PORT M1 ISO CASE DRAIN PORT L1 SAE J1926/ 1 ISO /16-18 SAE J1976/ 1 7/8-14 SY STEM PORT B (OUTLET POR T) ISO SAE J1926/ 1 1 5/16-12 APPR OX IM AT E CENTER OF GR AV IT Y [4.5] 15 [.59] R1 MA X [.4] CASE DRAI N PORT L1 SPO TF AC E DEPTH [3.24] Ø11.58 ±.25 [3.999 ±.1] SY STEM PORT S (INLET POR T) ISO SAE J1926/1 1 7/ [1.4 ] [1.75] Clockwise rotation, O-ring boss ports CASE DRAI N PORT L2 SPO TF AC E DEPTH [3.5] [7.83] 9. 4 [.37] SY STEM PORTS (INLET POR T) ISO SAE J1926/ 1 1 7/8-12 SY STEM PORT B (OUTLET POR T) ISO SAE J1926/1 1 5/ [1.8 ] [1.43] Counterclockwise rotation, O-ring boss ports CASE DRAIN PORT L2 ISO SAE J1926/ 1 7/ [5.4 ] 37 [1.46] P16 172E Third-angle projection mm [in] 52L519 Rev FJ September 28 61

62 Frame J installation drawings (continued) Axial ported endcap (continued) The drawings on these pages show a pump with two-bolt SAE-B and SAE-C mounting flanges. This pump is also available with a four-bolt SAE-C mounting flange. The differences are detailed in the drawing to the right. All other dimensions are common [.5] Ø14.4 [.567] X4 Ø ±.25 [4.999 ±.1] [2.25] 2X [4.51] 2X SAE-C four-bolt housing APPR OX IM AT E CENTER OF GR AV IT Y 11.2 [.4]. 9 [.4] PC PRESSURE ADJUSTMENT LS ST ANDBY PRESSURE ADJUSTMENT [3.65] LS SIGNAL PORT X 96.7 [3.81] 146 [5.75] 73 [2.87] [3.4] 53.3 [2.1] LS SIGNAL PORT X AL TERNA TE Ø14. 4 [.567] 2X [9.15] 93 [3.66] P14 234E PC only control Third-angle projection mm [in] 62 52L519 Rev FJ September 28

63 Frame J installation drawings (continued) Axial ported endcap (continued) Ø5.8 [2] OUTLET SYSTEM PORT S (INLET PORT) 27 bar 3 PSI [3.62] SPLIT FLANGE BOSS [1.688] PER ISO SAE J518 [1.43] (CODE 61) with 1/2-13 UNC X 27 [1.63] MIN THREAD Clockwise rotation, split-flange ports Ø25.4 [1] OUTLET SYSTEM PORT B (OUTLET PORT) bar 5 PSI [2.62] SPLIT FLANGE BOSS PER ISO 6162 SAE J518 (CODE 61) with 3/8-16 UNC X [.732] MIN THREAD [1.31] 44.5 [1.75] [2.62] Ø25.4 [1] OUTLET SYSTEM PORT B (OUTLET PORT) 345 bar 5 PSI SPLIT FLANGE BOSS PER ISO 6162 SAE J (CODE 61) [1.75] with 3/8-16 UNC [1.31] [3.62] [1.688] 36.2 [1.43] Ø5.8 [2] OUTLET SYSTEM PORT S (INLET PORT) 27 bar 3 PSI SPLIT FLANGE BOSS PER ISO 6162 SAE J518 (CODE 61) with 1/2-13 UNC X 23 [.96] MIN THREAD Counter clockwise rotation, split-flange ports 52L519 Rev FJ September 28 63

64 Frame J installation drawings Radial ported endcap 47 [1.85] CASE DRAIN PORT L1 PER ISO SAE J 1976/1 7/ [3.23] LS SIGNAL PORT X SAE J1926/ [4.59] BOTH SIDES 99.4 [3.9] 44.9 [1.77] BOTH SIDES LS STANDBY PRESSURE ADJUSTMENT PC PRESSURE ADJUSTMENT [9.44] LS SIGNAL PORT X 2.4 [7.89] LS SIGNAL PORT X ALTERNATE 15 [.59] R1 MAX [.4] 132 [5.2] CASE DRAIN PORT L1 SPOTFACE DEPTH 82.4 [3.24] SYSTEM PORT B OUTLET SYSTEM PORT S INLET CASE DRAIN PORT L2 SPOTFACE DEPTH 77.5 [3.5] Ø11.58 ±.25 [3.999 ±.1] 76.2 [3] 84 [3.31] Counterclockwise rotation Ø5.8 [2] INLET SYSTEM PORT S (INLET PORT) 27 BAR [3 PSI} SPLIT FLANGE PER ISO 6162 SAE J518 (CODE 61) with 1/2-13 UNC X 27 [1.63] MIN THREAD DEPTH [9.54] [7.66] 9.4 [.37] SYSTEM PORT S INLET SYSTEM PORT B OUTLET 37 [1.46] 84 [3.31] 76.2 [3] Clockwise rotation CASE DRAIN PORT L2 PER ISO SAE J1926/1 7/ [5.4] P16 173E Third-angle projection mm [in] 64 52L519 Rev FJ September 28

65 Frame J installation drawings (continued) APPR OX IM AT E CENTER OF GR AV IT Y 1.4 [.4] 3.2 [.1 ] Radial ported endcap (continued) The drawings on these pages show a pump with two-bolt SAE-B and SAE-C mounting flanges. This pump is also available with a four-bolt SAE-C mounting flange. The differences are detailed in the drawing to the right. All other dimensions are common. Ø ±.25 [4.999 ±.1] [.5] SAE-C four-bolt housing Ø14.4 [.567] X [5.1] [2.25] 2X [4.51] 2X APPR OX IM AT E CENTER OF GR AV IT Y [3.8 ] 146 [5.75] [2.62] 73 [2.87] [3.4] [9.45] Ø14. 4 [.567] 2X Ø25.4 [1] SY STEM PORT B (OUTLET POR T) 345 BAR [5 PSI] SPLIT FLANGE PER ISO 6162 SAE J518 (C ODE 61) with 3/8-16 UNC X 22 [.866] MINIMUM THREAD DEPTH [7.43] [1.31] [4.2] P14 236E PC only control Third-angle projection mm [in] 52L519 Rev FJ September 28 65

66 Frame J installation drawings (continued) Electric on/off control/radial endcap 99.4 [3.91] 6.92 [2.4] [11.31] 6.92 [2.4] 99.4 [3.91] [11.31] [5.51] [5.51] 2 Radial endcap with electric on/off right control (clockwise) Radial endcap with electric on/off left control (counterclockwise) 76.9 [3.3] 83.4 [3.28] 269. [1.62] 83.4 [3.28] 76.9 [3.3] 269. [1.62] [5.55] 141. [5.55] 141 [5.55] Axial endcap with electric on/off right control (counter clockwise) Axial endcap with electric on/off left control (clockwise) P16 191E Third-angle projection mm [in] 66 52L519 Rev FJ September 28

67 Frame J Displacement limiter endcaps [9.5] [8.2] [6.6] [8.2] [6.6] [6.4] [5.8] [6.4] [5.8] Radial endcap - counterclockwise [9.5] Axial endcap - counterclockwise [9.5] [8.2] [6.6] [8.2] [6.6] [6.4] [5.8] [6.4] [5.8] Radial endcap - clockwise [9.5] Axial endcap - clockwise P16 728E Third-angle projection mm [in] 52L519 Rev FJ September 28 67

68 Frame F Design Series 45 Frame F pumps have a dual servo piston design with a cradle-type swashplate set in polymer-coated journal bearings. The bias piston increases swashplate angle. The servo piston decreases swashplate angle. At equal pressure, the larger diameter servo piston overpowers the bias piston. Nine reciprocating pistons displace fluid from the pump inlet to the pump outlet as the cylinder block rotates on the pump input shaft. The block spring holds the piston slippers to the swashplate via the slipper retainer. The cylinder block rides on a bi-metal valve plate optimized for high volumetric efficiency and low noise. Tapered roller bearings support the input shaft and a viton lip-seal protects against shaft leaks. An adjustable one spool (PC only, not shown) or two spool (LS) control senses system pressure and load pressure (LS controls). The control ports system pressure to the servo piston to control pump output flow. Frame F cross section LS contro l (attached to endcap) LS spoo l LS adjustmen t PC spoo l PC adjustmen t Se rv o piston Bias sprin g Piston Slipper Ta pered roller bearing V alv e plate Shaf t seal C ylinder block spring Ta pere d roller bearing Input shaf t C ylinder block Bias piston Slipper retainer Swashplat e P14 341E 68 52L519 Rev FJ September 28

Series 45 Frame J Axial Piston Open Circuit Pumps. Technical Information

Series 45 Frame J Axial Piston Open Circuit Pumps. Technical Information Series 45 Frame J Axial Piston Open Circuit Pumps Technical Information Using this manual ORGANIZATION AND HEADINGS To help you quickly find information in this manual, the material is divided into sections,

More information

Technical Information Series 45 G Frame powersolutions.danfoss.com

Technical Information Series 45 G Frame powersolutions.danfoss.com MAKING MODERN LIVING POSSIBLE Technical Information Series 45 G Frame powersolutions.danfoss.com Contents Frame G Design... 4 Specifications... 5 Performance G74B... 6 Performance G9C... 7 Order code...

More information

Series 45 Open Circuit Axial Piston Pumps. Technical Information. Displacement Piston. Swashplate. Piston. Tapered Roller Bearing

Series 45 Open Circuit Axial Piston Pumps. Technical Information. Displacement Piston. Swashplate. Piston. Tapered Roller Bearing Series 45 Open Circuit Axial Piston Pumps Technical Information Displacement Piston Piston Swashplate Tapered Roller earing Tapered Roller earing Valve Plate Cylinder lock Kit Shaft Seal General Description

More information

Series 45 Axial Piston Open Circuit Pumps Technical Information Frame F

Series 45 Axial Piston Open Circuit Pumps Technical Information Frame F Design cross section LS contro l (attached to endcap) LS spoo l LS adjustmen t PC spoo l PC adjustmen t Servo piston Bias sprin g Piston Slipper Tapered roller bearing Valve plate Shaft seal Cylinder block

More information

Series 45 Axial Piston Open Circuit Pumps Technical Information

Series 45 Axial Piston Open Circuit Pumps Technical Information Design Frame E cross section LS control (attached to endcap) LS spool PC spool LS adjustment PC adjustment Adjustable displacement limiter Lifting lug Displacement piston guide Displacement piston Slipper

More information

Series 20 Axial Piston Pumps. Technical Information

Series 20 Axial Piston Pumps. Technical Information Series 20 Axial Piston Pumps Technical Information General Description INTRODUCTION Sauer-Danfoss a world leader in hydraulic power systems has developed a family of axial piston pumps. DESCRIPTION Sauer-Danfoss

More information

Series 20 Axial Piston Pumps. Technical Information

Series 20 Axial Piston Pumps. Technical Information Series 20 Axial Piston Pumps Technical Information General Description INTRODUCTION Sauer-Danfoss a world leader in hydraulic power systems has developed a family of axial piston pumps. DESCRIPTION Sauer-Danfoss

More information

Series 40 Axial Piston Motors

Series 40 Axial Piston Motors Technical Information powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev February 2017 Corrected document formatting 0703 October 2016 Minor updates 0702 January 2014 Danfoss

More information

L and K Frame Variable Motors. Technical Information

L and K Frame Variable Motors. Technical Information L and K Frame Variable Motors Technical Information Revisions Revisions Table of Revisions Date Page Changed Rev. April 2008 6 corrected the schematic drawings BE January 2008 17 removed displacement limiter

More information

Technical Information Series 45 H Frame powersolutions.danfoss.com

Technical Information Series 45 H Frame powersolutions.danfoss.com MAKING MODERN LIVING POILE Technical Information eries 45 H Frame powersolutions.danfoss.com Contents Frame H Design... 4 pecifications... 5 Performance H57... 6 Performance H75D... 7 Order code... 8 Controls...

More information

D1 High Power Open Circuit Pumps Size 130/145/193/260

D1 High Power Open Circuit Pumps Size 130/145/193/260 Technical Information D1 High Power Open Circuit Pumps Size 130/145/193/260 Available only for APAC / EU regions powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev January

More information

Series 40 Direct Displacement Pumps

Series 40 Direct Displacement Pumps Technical Information powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev July 2017 Removed outdated images 0703 January 2017 Minor updates 0702 July 2015 Minor edits 0701 February

More information

Series 90 Axial Piston Motors. Technical Information

Series 90 Axial Piston Motors. Technical Information Series 90 Axial Piston Motors Technical Information HISTORY OF REVISIONS Table of Revisions Date Page Changed Rev. Fourth edition 2 520L0604 Contents GENERAL DESCRIPTION Cross section Cross section Cross

More information

Series 90 Axial Piston Pumps. Technical Information

Series 90 Axial Piston Pumps. Technical Information Series 90 Axial Piston Pumps Technical Information Revisions History of Revisions Table of Revisions Date Page Changed Rev. March 2010 Various Fix O-ring dimensions in dimension drawings FE December 2009

More information

Group 3 Gear Pumps. Technical Information. OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP

Group 3 Gear Pumps. Technical Information. OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP Group 3 Gear Pumps OpenCircuitGear Technical Information General Information History of revisions Table of revisions Date Page Changed Rev. 28, June 21 - First edition A 24, Feb 211 1,2,11, 32 Covers to

More information

shhark continuum PUMPS Group 1 l Technical Information

shhark continuum PUMPS Group 1 l Technical Information shhark continuum PUMPS Group 1 l Technical Information 66M 88Y 55K 77C 33M 50C 100Y 66M 88Y 2 GROUP 1 shhark continuum PUMPS I TECHNICAL INFORMATION History of revisions Date Page Changed Rev. May 2016

More information

T1P Transit Mixer Axial Piston Pump Size 069/089

T1P Transit Mixer Axial Piston Pump Size 069/089 Technical Information T1P Transit Mixer Axial Piston Pump Size 069/089 powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev May 2016 Updated to Engineering Tomorrow design. 0201

More information

Series TMM Axial Piston Motor. Technical Information

Series TMM Axial Piston Motor. Technical Information Series TMM Axial Piston Motor Technical Information General Description GENERAL DESCRIPTION These motors are designed primarily to be combined with other products in closed circuit systems to transfer

More information

CAST IRON GEAR PUMPS AND MOTORS Cascade Group 3 l Technical Information

CAST IRON GEAR PUMPS AND MOTORS Cascade Group 3 l Technical Information CAST IRON GEAR PUMPS AND MOTORS Cascade Group 3 l Technical Information 2 CASCADE GROUP 3 I TECHNICAL INFORMATION History of revisions Date Page Changed Rev. March 2015 - First edition - September 2016

More information

Series 20 Axial Piston Motors. Technical Information

Series 20 Axial Piston Motors. Technical Information Series 20 xial Piston Motors Technical Information General Description INTRODUCTION Sauer-Danfoss a world leader in hydraulic power systems has developed a family of axial piston motors. DESCRIPTION Sauer-Danfoss

More information

Series 40 Axial Piston Motors. Technical Information

Series 40 Axial Piston Motors. Technical Information Series 40 Axial Piston Motors Technical Information Revisions Revisions Table of Revisions Date Page Changed Rev. November 2007 31 correction to maximum torque rating 15 and 19 tooth FB April 2007 29 Revised

More information

H1 Axial Piston Tandem Pumps Size 045/053

H1 Axial Piston Tandem Pumps Size 045/053 MAKING MODERN LIVING POSSIBLE Technical Information H1 Axial Piston Tandem Pumps Size 045/053 powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev November 2015 Master Model

More information

Group 1 Gear Pumps. Technical Information. OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP

Group 1 Gear Pumps. Technical Information. OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP Group Gear Pumps OpenCircuitGear Technical Information General Information History of revisions Table of revisions Date Page Changed Rev., June - First edition A, Feb,,, Covers to blue color, TurollaOCG

More information

H1 Axial Piston Pump Size 115/130, Single. Technical Information

H1 Axial Piston Pump Size 115/130, Single. Technical Information H1 Axial Piston Pump Size 115/130, Single Technical Information Revisions Revision History Table of revisions Date Page Changed Rev 30 Jul, 2009 First edition AA Jun, 2010 4-6, 12, 14, New EC directive

More information

Series 90 Axial Piston Pumps. Technical Information

Series 90 Axial Piston Pumps. Technical Information Series 90 Axial Piston Pumps Technical Information Using this manual ORGANIZATION AND HEADINGS To help you quickly find information in this manual, the material is divided into sections, topics, subtopics,

More information

Series 20 Axial Piston Motors. Technical Information

Series 20 Axial Piston Motors. Technical Information Series 20 xial Piston Motors Technical Information General Description INTRODUCTION Sauer-Danfoss a world leader in hydraulic power systems has developed a family of axial piston motors. DESCRIPTION Sauer-Danfoss

More information

GEAR PUMPS Group 3 l Technical Information

GEAR PUMPS Group 3 l Technical Information GEAR PUMPS Group 3 l Technical Information 2 GROUP 3 GEAR PUMPS I TECHNICAL INFORMATION History of revisions Date Page Changed Rev. 28, June 2010 - First edition A 24, Feb 2011 1,2,11,32 Covers to blue

More information

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s H y d r a u l i c s ydraulics Eaton Medium Duty Piston Pump h y d r a u l i c s Model 70122, 70422, 70423, and 70523 or -Flow Compensated Piston Pumps We Manufacture April 1997 Solutions S o l u t i o

More information

Series 40 Axial Piston Pumps. Technical Information

Series 40 Axial Piston Pumps. Technical Information Series 40 Axial Piston Pumps Technical Information Revisions History of Revisions Table of Revisions Date Page Changed Rev. October 2010 last new last page EJ February 2010 last Fix Osaka address EI June

More information

Group 3 Gear Pumps. Technical Information. OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP

Group 3 Gear Pumps. Technical Information. OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP Group 3 Gear Pumps OpenCircuitGear Technical Information General Information History of revisions Table of revisions Date Page Changed Rev. 28, June 21 - First edition 24, Feb 211 1,2,11, 32 Covers to

More information

Gear Motors Group 1, 2 and 3. Technical Information. OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP

Gear Motors Group 1, 2 and 3. Technical Information. OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP Gear Motors Group 1, 2 and 3 OpenCircuitGear Technical Information Gear Motors Group 1, 2 and 3 General Information Overview The Turolla OCG Gear Motors is a range of peak performance fixed displacement

More information

H1 Axial Piston Tandem Pumps Size 045/053/060/068

H1 Axial Piston Tandem Pumps Size 045/053/060/068 Technical Information H1 Axial Piston Tandem Pumps Size 045/053/060/068 powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev September 2017 add G6 option 0603 June 2017 minor

More information

Series PVP Variable Volume Piston Pumps

Series PVP Variable Volume Piston Pumps Series PVP Variable Volume Piston Pumps Catalog HY28-2661-CD/US zp2 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference Only

More information

H1 Axial Piston Pump Size 045/053, Single. Technical Information

H1 Axial Piston Pump Size 045/053, Single. Technical Information H1 Axial Piston Pump Size 045/053, Single Technical Information Revisions Revision History Table of revisions Date Page Changed Rev 30 Jul, 2009 First edition AA Feb 2010 various 14 teeth added BA Jun,

More information

Distribuíção, revenda emanutenção. CatálogosOnline. (11) (11)

Distribuíção, revenda emanutenção. CatálogosOnline. (11) (11) Distribuíção, revenda emanutenção CatálogosOnline (11)4174-3300-(11)4765-6775 www.hmc.com.br MAKING MODERN LIVING POSSIBLE Technical Information Axial Piston Pumps Series 20 powersolutions.danfoss.com

More information

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA Catalog HY28-6/NA PV, PVT Series Piston Pumps Variable Volume Catalog HY28-6/NA 1 Catalog HY28-6/NA Notes Series PV 2 Catalog HY28-6/NA Introduction Series PV Quick Reference Data Chart Pump Delivery Approx.

More information

P90 VARIABLE DISPLACEMENT PUMP T E C H N I C A L C A T A L O G

P90 VARIABLE DISPLACEMENT PUMP T E C H N I C A L C A T A L O G P90 VARIABLE DISPLACEMENT PUMP T E C H N I C A L C A T A L O G Variable displacement pump POCLAIN HYDRAULICS Design Slider block Swashplate hold-down Servo piston Servo arm Piston Slipper Displacement

More information

Group 1. Gear Pumps Technical Information

Group 1. Gear Pumps Technical Information Group Gear Pumps Technical Information Group Family of Gear Pumps SAUER-SUNDSTRAND High performance gear pumps are fixed displacement pumps which consist of the pump housing, drive gear, driven gear, DU

More information

Directional Control Valve Model Technical Information. Phased Out OUT BASE BKT CYL ROD

Directional Control Valve Model Technical Information. Phased Out OUT BASE BKT CYL ROD BASE BKT CYL ROD OUT IN Directional Control Valve Model 1480 Technical Information History of Revisions Revisions Table of Revisions Date Page Changed Rev. May 2008 - first edition AA 2008 Sauer-Danfoss.

More information

Axial Piston Pumps LPV

Axial Piston Pumps LPV Technical Information Axial Piston Pumps LPV powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev September 2017 update model code 0102 July 2015 Danfoss Layout 0100 January

More information

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW AXIAL PISTON PUMPS SHPV SECTIONAL VIEW 2 SYSTEM CIRCUIT PUMP AND MOTOR CIRCUIT working loop (high pressure) working loop (low pressure) control fluid suction line case drain fluid Above figure shows schematically

More information

GEAR PUMPS Group 4 l Technical Information

GEAR PUMPS Group 4 l Technical Information GEAR PUMPS Group 4 l Technical Information 2 GROUP 4 GEAR PUMPS I TECHNICAL INFORMATION History of revisions Date Page Changed Rev. 28, June 2010 - First edition A 30, Sept 2013 ALL Layout and options

More information

MAKING MODERN LIVING POSSIBLE. Technical Information. Series 45 Pumps. powersolutions.danfoss.com

MAKING MODERN LIVING POSSIBLE. Technical Information. Series 45 Pumps. powersolutions.danfoss.com MAKING MODERN LIVING POSSIBLE Technical Information powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev October 214 Add ETL control and Angle Sensor HB July 214 Danfoss layout

More information

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi)

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi) Vickers Vane Pumps VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi) 5008.00/EN/0596/A A.25 Introduction From the

More information

Series 90 Axial Piston Pumps. Technical Information

Series 90 Axial Piston Pumps. Technical Information Series 90 Axial Piston Pumps Technical Information Revisions History of Revisions Table of Revisions Date Page Changed Rev. July 2011 35 Typo, 45cc should be 42cc GB July 2011 all Major update GA August

More information

Series 40 Direct Displacement Pumps. Technical Information

Series 40 Direct Displacement Pumps. Technical Information Series 40 Direct Displacement Pumps Technical Information Revisions History of Revisions Table of Revisions Date Page Changed Rev. September 2013 5, 11 change system pressure specs FB August 2013 all Remove

More information

H1 Axial Piston Pump Size 147/165, Single. Technical Information

H1 Axial Piston Pump Size 147/165, Single. Technical Information H1 Axial Piston Pump Size 147/165, Single Technical Information Revisions Revision History Table of revisions Date Page Changed Rev 30 Jul, 2009 First edition AA Jul, 2010 4-6, 10, 12-13 New EC directive

More information

LPV Axial Piston Closed Circuit Pumps. Technical Information

LPV Axial Piston Closed Circuit Pumps. Technical Information LPV Axial Piston Closed Circuit Pumps Technical Information Revisions History of Revisions Table of Revisions Date Page Changed Rev. October 2008 6 added serial number plate drawing AE April 2008 29 changes

More information

Series 42 4T Axial Piston Tandem Pumps

Series 42 4T Axial Piston Tandem Pumps Technical Information Series 42 4T Axial Piston Tandem Pumps powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev June 2016 converted to new layout 0101 May 2015 Converted to

More information

Gear Motors Group 1, 2 and 3. Technical Information. OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP

Gear Motors Group 1, 2 and 3. Technical Information. OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP Gear Motors Group 1, 2 and 3 OpenCircuitGear Technical Information Gear Motors Group 1, 2 and 3 General Information Overview The Turolla OCG Gear Motors is a range of peak performance fixed displacement

More information

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93 Vickers Vane Pumps Double Thru-drive Vane Pumps High speed, high pressure VQT Series for mobile equipment Released 7/93 612 Introduction Double VQT high performance pumps are fixed displacement units that

More information

GEAR MOTORS D Series Gear Motors including Fan Drive l Technical Information

GEAR MOTORS D Series Gear Motors including Fan Drive l Technical Information GEAR MOTORS D Series Gear Motors including Fan Drive l Technical Information 2 D SERIES GEAR MOTORS I TECHNICAL INFORMATION History of revisions Date Page Changed Rev. Feb. 2009 - First edition AA Nov.

More information

Open Circuit Axial Piston Pumps Series 45 Frame K and L

Open Circuit Axial Piston Pumps Series 45 Frame K and L Service Manual Open Circuit Axial Piston Pumps Series 45 Frame K and L powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev August 2016 Updated tables and Adjustments chapter

More information

Axial Piston Pumps Series 40 M46

Axial Piston Pumps Series 40 M46 Technical Information Axial Piston Pumps Series 40 M46 powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev March 2017 Minor updates - FNR Control options 0209 October 2016 Minor

More information

Group 2 Gear Pumps. Technical Information. OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP

Group 2 Gear Pumps. Technical Information. OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP Group 2 Gear Pumps OpenCircuitGear Technical Information General Information History of revisions Table of revisions Date Page Changed Rev. 28, June 21 - First edition A 24, Feb 211 1, 2, 12, 44 Covers

More information

Series 42 Axial Piston Pumps. Technical Information

Series 42 Axial Piston Pumps. Technical Information Series 42 Axial Piston Pumps Technical Information Revisions History of Revisions Table of Revisions Date Page Changed Rev. October 2009 59 Connector/Spool: 6=MS, high gain spool CC October 2009 8, 11

More information

D Series Gear Motors Including Fan Drive. Technical Information

D Series Gear Motors Including Fan Drive. Technical Information D Series Gear Motors Including Fan Drive Technical Information Revisions History of Revisions Table of Revisions Date Page Changed Rev. February 09 - First edition AA 09 Sauer-Danfoss. All rights reserved.

More information

420 Mobile Piston Pump

420 Mobile Piston Pump 420 Mobile Piston Pump Technical Catalog Manual ADU041 ADU049 ADU062 Introduction 420 Series mobile pumps are open circuit, axial piston designs. A variety of controls provides the ability to match the

More information

H1 Bent Axis Variable Displacement Motors Frame Size 080 Frame Size 110. Technical Information

H1 Bent Axis Variable Displacement Motors Frame Size 080 Frame Size 110. Technical Information H1 Bent Axis Variable Displacement Motors Frame Size 080 Frame Size 110 Technical Information Revisions History of Revisions Table of revisions Date Page Changed Rev. 1 Dec, 2008 Different pages New frame

More information

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691

Vickers. Piston Motors. Inline Piston Motors. Fixed and Variable Displacement. Revised 5/99 691 Vickers Piston Motors Inline Piston Motors Fixed and Variable Displacement Revised 5/99 691 Table of Contents Introduction........................................................................................

More information

Group 1 Gear Pumps Technical Information General Information

Group 1 Gear Pumps Technical Information General Information General Information OVERVIEW The Sauer-Danfoss Group is a range of peak performance fixed-displacement gear pumps. Constructed of a high-strength extruded aluminum body with aluminum cover and flange,

More information

H1T 045/053/060/068 H1 Axial Piston Tandem Pumps

H1T 045/053/060/068 H1 Axial Piston Tandem Pumps Technical Information H1T 045/053/060/068 H1 Axial Piston Tandem Pumps www.danfoss.com Revision history Table of revisions Date Changed Rev July 2018 Major revision. 0801 June 2018 Angle sensor chapters

More information

4T Axial Piston Pumps. Technical Information

4T Axial Piston Pumps. Technical Information 4T Axial Piston Pumps Technical Information Using this manual ORGANIZATION AND HEADINGS To help you quickly find information in this manual, the material is divided into sections, topics, subtopics, and

More information

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES Certified Company ISO 9001-14001 ISO 9001 Via M. L. King, 6-41122 MODENA (ITALY) Tel: +39 059 415 711 Fax: +39 059 415 729 / 059 415

More information

Group 1 Gear Pumps. Technical Information. OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP

Group 1 Gear Pumps. Technical Information. OpenCircuitGear MEMBER OF THE SAUER-DANFOSS GROUP Group 1 Gear Pumps OpenCircuitGear Technical Information General Information History of revisions Table of revisions Date Page Changed Rev., June 1 - First edition Reference documents Literature reference

More information

Medium Duty Piston Pump Variable Displacement Closed Circuit

Medium Duty Piston Pump Variable Displacement Closed Circuit Medium Duty Piston Pump Variable Displacement Closed Circuit Model 70160 Model 70360 Model 72400 20.3 cm 3 /r [1.24 in 3 /r] 40.6 cm 3 /r [2.48 in 3 /r] 40.6 cm 3 /r [2.48 in 3 /r] 23.6 cm 3 /r [1.44 in

More information

H1 Axial Piston Single Pumps Size 147/165

H1 Axial Piston Single Pumps Size 147/165 MAKING MODERN LIVING POSSIBLE Technical Information H1 Axial Piston Single Pumps Size 147/165 powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev September 2014 MDC, CCO, and

More information

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces: Axial piston variable pump A4VG Series 32 Europe RE-E 92003 Edition: 04.2016 Replaces: 06.2012 High-pressure pump for applications in a closed circuit Size 28 to 125 Nominal pressure 400 bar Maximum pressure

More information

L and K Frame Variable Motors

L and K Frame Variable Motors Technical Information powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev April 2018 Model code minimum angle update 0204 November 2016 Minor updates 0203 June 2015 new cartridge

More information

PowrFlow PVX Vane Pumps

PowrFlow PVX Vane Pumps PowrFlow PVX Vane Pumps POWRFLOW PVX VANE PUMPS YOUR SOURCE FOR VANE PUMPS FOR THE MOST DEMANDING APPLICATIONS What Makes PowrFlow PVX Vane Pumps Your Best Buy? Continental Hydraulics PowrFlow PVX Vane

More information

Series 90 Axial Piston Pumps

Series 90 Axial Piston Pumps MAKING MODERN LIVING POSSIBLE Series 90 Axial Piston Pumps powersolutions.danfoss.com Revision History Table of Revisions Date Changed Rev March 2014 corrections to pin assignments - page 48 FB February

More information

Transit Mixer Axial Piston Motor Size 070/084/089

Transit Mixer Axial Piston Motor Size 070/084/089 Technical Information Transit Mixer Axial Piston Motor Size 070/084/089 powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev June 2017 Update to Engineering Tomorrow 0202 Mar

More information

DDC20 Axial Piston Variable Displacement Pump

DDC20 Axial Piston Variable Displacement Pump Technical Information DDC20 Axial Piston Variable Displacement Pump powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev February 2017 Change charge pump housing 0102 January

More information

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS GEARBOXES - ACCESSORIES THE PRODUCTION LINE OF HANSA-TMP Variable Displacement Closed Loop System CONTENTS General Information... Order Code... Manual Control

More information

Series 42 Closed Circuit Axial Piston Pumps

Series 42 Closed Circuit Axial Piston Pumps Technical Information Series 42 Closed Circuit Axial Piston Pumps www.danfoss.com Revision history Table of revisions Date Changed Rev August 2018 Minor Update 0103 December 2016 Minor Update 0102 June

More information

Mobile Piston Pump Series 620

Mobile Piston Pump Series 620 Mobile Piston Pump Series 620 01.2016 inspired hydraulics. Änderungen und Druckfehler vorbehalten 01.2016 EN 620er Pumpe_EN english Mobile Piston Pump Series 620 Introduction 620 Series Piston Pump Eaton

More information

D Series. Technical Information. OpenCircuitGear. Cast Iron Gear Pumps MEMBER OF THE SAUER-DANFOSS GROUP

D Series. Technical Information. OpenCircuitGear. Cast Iron Gear Pumps MEMBER OF THE SAUER-DANFOSS GROUP D Series Cast Iron Gear Pumps Revisions History of Revisions Table of Revisions Date Page Changed Rev. Jun, 2010 - First edition A December 2010 all Major update B April 2011 all Major update C October

More information

Catalog PowrFlowTM PVX Vane Pumps

Catalog PowrFlowTM PVX Vane Pumps Catalog PowrFlowTM PVX Vane Pumps Your source for vane pumps for the most demanding applications. What Makes PowrFlow PVX Vane Pumps Your Best Buy? Continental Hydraulics PowrFlow PVX Vane Pumps deliver

More information

Hydraulic Pump Series VP1 Variable Displacement

Hydraulic Pump Series VP1 Variable Displacement Variable Displacement Catalog 9129 8222-02 February 1999, GB Content Page General information 3 Design 3 Specifications 4 Ordering information 4 VP1 cross section 4 Installation dimensions 5 Line dimensioning

More information

P90 VARIABLE DISPLACEMENT PUMP T E C H N I C A L C A T A L O G

P90 VARIABLE DISPLACEMENT PUMP T E C H N I C A L C A T A L O G P90 VARIABLE DISPLACEMENT PUMP T E C H N I C A L C A T A L O G Variable displacement pump POCLAIN HYDRAULICS Design Piston Slipper Slider block Servo piston Servo arm Displacement control Feedback linkage

More information

PM50 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C A L C A T A L O G

PM50 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C A L C A T A L O G PM50 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT T E C H N I C A L C A T A L O G PM50 - Variable displacement pump POCLAIN HYDRAULICS OVERVIEW PM50 is a variable displacement, axial piston pump, with

More information

Series 90. Axial Piston Motors Technical Information

Series 90. Axial Piston Motors Technical Information Series 90 Axial Piston Motors Technical Information Series 90 Family of Pumps and Motors Series 90 hydrostatic pumps and motors can be applied together or combined with other products in a system to transfer

More information

Variable Displacement Piston Pumps Series P2/P3. General Information. P3 Series

Variable Displacement Piston Pumps Series P2/P3. General Information. P3 Series General Information General Information P2 Series The newly developed variable displacement piston pumps from Parker Hannifin, designated P2, are intended for mobile applications, featuring a very compact

More information

Vickers 45. VMQ Series 30 Vane Pumps. Fixed Displacement, For Industrial and Mobile Applications (4.188)

Vickers 45. VMQ Series 30 Vane Pumps. Fixed Displacement, For Industrial and Mobile Applications (4.188) [ (4.188) 49,4 (1.94) /21,8 /.86) 174,7/172,3 (6.88/6.78) 332,9/33,5 (13.11/13.1) "M" is marked if metric port threads No marking if inch port threads AS-568-152 O-ring Vickers 45 65,3 (2.57) 13 (5.1 VMQ

More information

GEAR PUMPS D Series and XD Series Gear Pumps l Technical Information

GEAR PUMPS D Series and XD Series Gear Pumps l Technical Information GEAR PUMPS D Series and XD Series Gear Pumps l Technical Information 2 D SERIES AND XD SERIES GEAR PUMPS I TECHNICAL INFORMATION History of Revisions Date Page Changed Rev. Jun, 2010 - First edition A

More information

H1 Axial Piston Pump Size 147/165, Single

H1 Axial Piston Pump Size 147/165, Single MAKING MODERN LIVING POSSIBLE Technical Information H1 Axial Piston Pump Size 147/165, Single powersolutions.danfoss.com Revision History Table of Revisions Date Changed Rev Mar 2014 Converted to Danfoss

More information

SCM SAE. Other advantages: Sunfab s SCM SAE is a range of robust axial piston motors especially suitable for mobile hydraulics.

SCM SAE. Other advantages: Sunfab s SCM SAE is a range of robust axial piston motors especially suitable for mobile hydraulics. Sunfab s SCM 010-130 SAE is a range of robust axial piston motors especially suitable for mobile hydraulics. SCM 010-130 SAE is of the bent-axis type with spherical pistons. The design results in a compact

More information

Open Circuit Axial Piston Pumps Series 45 Frame K2

Open Circuit Axial Piston Pumps Series 45 Frame K2 Open Circuit Axial Piston Pumps Series 45 Frame K2 powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev April 2017 First edition 0101 2 Danfoss April 2017 AX00000301en-US0101

More information

AXIAL PISTON MOTORS SHMF

AXIAL PISTON MOTORS SHMF SECTIONAL VIEW Purge relief valve High pressure relief valves (adjustable) Cylinder block assembly Shaft seal Output shaft Valve block Shuttle valve Swashplate 2 SYSTEM CIRCUIT PUMP AND MOTOR CIRCUIT working

More information

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW AXIAL PISTON PUMPS SHPV SECTIONAL VIEW 2 AXIAL PISTON PUMPS SHPV SYSTEM CIRCUIT PUMP AND MOTOR CIRCUIT working loop (high pressure) working loop (low pressure) control fluid suction line case drain fluid

More information

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model AA4VSE Plug-in dual displacement motor Series Axial piston swashplate design, SAE model RE 91808/09.90 RE 91808/09.90 Brueninghaus Hydromatik Size 250 Nominal pressure 350 bar Peak pressure 400 bar High

More information

H1 Axial Piston Single Pumps Size 147/165

H1 Axial Piston Single Pumps Size 147/165 Technical Information H1 Axial Piston Single Pumps Size 147/165 powersolutions.danfoss.com Revision history Table of revisions Date Changed Rev May 2017 NFPE gen. 3 changes. 0701 November 2015 Master Model

More information

Section 5: Hydraulic Pump SAUER DANFOSS. SERVICE MANUAL Property of American Airlines. 5-5 Page 1 September 09 HYDRAULIC PUMP

Section 5: Hydraulic Pump SAUER DANFOSS. SERVICE MANUAL Property of American Airlines. 5-5 Page 1 September 09 HYDRAULIC PUMP Section 5: Hydraulic Pump SAUER DANFOSS SERVICE MANUAL HYDRAULIC PUMP 5-5 Page 1 September 09 THIS PAGE INTENTIONALLY LEFT BLANK Series 45 Frame G and H Open Circuit Axial Piston Pumps Service Manual Introduction

More information

Eaton PVM Variable Displacement Piston Pumps Vickers Product Line cc 3 ( in 3 )

Eaton PVM Variable Displacement Piston Pumps Vickers Product Line cc 3 ( in 3 ) Eaton PVM Variable Displacement Piston Pumps Vickers Product Line 18-141cc 3 (1.1-8.6in 3 ) Table of Contents M Series Variable Displacement Piston Pumps Introduction.... 3 Hydraulic System Design Calculations....

More information

SCM SAE. Other advantages: Sunfab s SCM SAE is a range of robust axial piston motors especially suitable for mobile hydraulics.

SCM SAE. Other advantages: Sunfab s SCM SAE is a range of robust axial piston motors especially suitable for mobile hydraulics. Sunfab s SCM 010-130 SAE is a range of robust axial piston motors especially suitable for mobile hydraulics. SCM 010-130 SAE is of the bent-axis type with spherical pistons. The design results in a compact

More information

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3

5.2 MEDIUM HEAVY DUTY SERIES SIZE 3 .2 MEDIUM HEAVY DUTY SERIES SIZE 3 CONTENTS PGI101 Ordering Code.2.1 Medium Heavy Duty Series Technical Information.2.2 Specifications.2.3 Hydraulic fluids.2.4 Viscosity range.2. Temperature range.2.6

More information

Technical Information Axial Piston Motors Series 20 powersolutions.danfoss.com

Technical Information Axial Piston Motors Series 20 powersolutions.danfoss.com MKING MODERN LIVING POSSILE Technical Information xial Piston Motors Series 20 powersolutions.danfoss.com General Information Introduction Danfoss a world leader in hydraulic power systems has developed

More information

PVE /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTMENT SERIES 30 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS

PVE /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTMENT SERIES 30 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS 14 110/117 ED PVE VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTMENT OPERATING PRINCIPLE The PVE pumps are variable displacement vane pumps with direct pressure regulator. The pump group

More information

Variable displacement axial piston pumps,

Variable displacement axial piston pumps, LVP 04 T E Variable displacement axial piston pumps, Edition: 04/04.2000 Replaces: 04/10.99 DISPLACEMENTS From To PRESSURE Max. continuous Max. intermittent Max. peak 29 cm 3 /rev 73 cm 3 /rev 280 bar

More information

H1 Axial Piston Single Pumps Size 147/165

H1 Axial Piston Single Pumps Size 147/165 H1 Axial Piston Single Pumps Size 147/165 www.danfoss.com Revision history Table of revisions Date Changed Rev September 2018 MMC update for M option added. 0802 May 2018 Angle sensor for EDC; FDC note

More information