Ampere Hour 77 F (25 C) Weight Weight Model #Cells/Voltage

Size: px
Start display at page:

Download "Ampere Hour 77 F (25 C) Weight Weight Model #Cells/Voltage"

Transcription

1 TEL SERIES Valve Regulated Lead Acid (VRLA) Battery Series Designed for Telecom Power Applications FEATURES & BENEFITS Telecordia certified life exceeding 10 years. Telecordia tested and qualified to meet all SR-4228 requirements. Flame-arresting, one-way pressure-relief vent for safety and long life. Thermally welded case-to-cover bond to ensure a leakproof seal. Flame-retardant polypropylene case and cover compliant with UL94 V-0 with an Oxygen Limiting Index of greater than 28. Absorbent Glass Mat (AGM) technology for efficient gas recombination 99% plus. Complies with UL1778, 924, 1989 and 94 V-0. UL-recognized component. Can be used in any orientation. Upright, side or end mounting recommended. Low-profile terminals with threaded copper alloy inserts for reduced height, reduced maintenance and increased safety. Front Access threaded copper alloy inserts on TEL12-105FS. Multicell design for ease of installation and maintenance. APPLICATIONS Customer Premise PBX Broadband Repeaters Wireless Fixed Wireline Not restricted for air transport - Classified as non-hazardous material, complies with IATA/ICAO Special Provision A67. Not restricted for surface transport - Classified as nonhazardous material, complies with DOT-CFR Title 49 parts TECHNICAL DATA Not restricted for water transport - Classified as nonhazardous material, complies with IMDG exception 238. Ampere Hour 77 F (25 C) Weight Weight Model #Cells/Voltage Operating Time (in hours) to 1.75 Volts Per Cell lbs kg TEL12-30 (*SLC) 6 Cells / 12 Volts TEL12-45 (*SLC) 6 Cells / 12 Volts TEL Cells / 12 Volts TEL12-80 (*SLC) 6 Cells / 12 Volts TEL Cells / 12 Volts TEL12-105FS** 6 Cells / 12 Volts TEL Cells / 12 Volts TEL Cells / 6 Volts *(SLC) battery includes cable assembly **TEL FS replaces TEL F. The TEL FS is 0.56 inches (14.33 mm) shorter than the TEL F /0814/CD

2 SPECIFICATIONS Operating Temperature Range with Temperature compensation Nominal Operation Temperature Range Recommended Maximum Charging Limit Float Charging Voltage Maximum AC Ripple (Charger) Self Discharge Equalize charge and cycle service voltage Terminal Inserted Inserted Copper Alloy Terminal Hardware Initial Torque Inter-unit Connector Terminal Protectors Discharge: -40 F (-40 C) to +160 F (71 C) Charge: -10 F (-23 C) to +140 F (60 C) +74 F (23 C) to +80 F (27 C) C/5 20 Hr 77 F (25 C) 13.5 to 13.8 average per 12V unit (6.75 to 6.90 per 6V 77 F (25 C) AC Ripple Voltage - 0.5% RMS or 1.5% P-P of float charge voltage recommended for best results. AC Ripple - Max current allowed = C/20 AMPS RMS (5 AMPS RMS Per 100Ah) Battery can be stored up to 6 months at 77 F (25 C) before a freshening charge is required. Batteries stored at temperatures greater than 77 F (25 C) will require recharge sooner than batteries stored at lower temperatures. See C&D bulletin , Self-Discharge and Inventory Control for details to VDC average per 12V 77 F (25 C); 7.20 to 7.40 VDC per 6V unit Threaded copper alloy insert terminal to accept: UNF 3 8 inch long screws for: TEL12-30, TEL12-30SLC, TEL12-45 & TEL12-45SLC) 1/4-20 UNC 3 4 inch long screws for: TEL12-70, TEL12-80, TEL12-80SLC, TEL12-90, TEL12-105FS, TEL & TEL in.-lbs. (3.4 N-m) for hardware 110 in.-lbs. (12.4 N-m) for hardware Included with the TEL12-105FS UL94 V0 Terminal protectors available D I M E N S I O N S 1.33 [ 33.7 ] 1/4-20 UNC 1.13 [ 28.7 ] 0.13 [ 3.2 ] (317.8) Note: All dimensions are for reference only. Lug & hardware dimensions not included. Batteries to be mounted with 0.5 in. (12.5 mm) spacing minimum allowing free air ventilation. Contact a C&D Representative for additional dimension information.*(slc) battery includes cable assembly. ** TEL12-105FS is a Front Access Battery and includes rope handles /0814/CD 2

3 TEL12-70 SPECIFICATIONS 69 8 hour rate to IEC Rating: Amperes TEL12-70 RATINGS Constant Discharge Ratings - 77 F (25 C) TEL12-80 (*SLC) SPECIFICATIONS 79 8 hour rate to IEC Rating: 77.5 (*SLC-30 Amps) * TEL12-80 SLC cable connectors ARE rated for ONLY 30 amps discharge 3300 Amperes TEL12-80 & TEL12-80SLC RATINGS TEL12-80SLC CABLE Constant Discharge Ratings - 77 F (25 C) /0814/CD 3

4 TEL12-90 SPECIFICATIONS 88 8 hour rate to IEC Rating: Amperes TEL12-90 RATINGS Constant Discharge Ratings - 77 F (25 C) TEL12-105FS SPECIFICATIONS hour rate to IEC Rating: Amperes TEL12-105FS RATINGS Constant Discharge Ratings - 77 F (25 C) Note: Batteries to be mounted with 0.3 in. (7.5 mm) spacing minimum allowing free air ventilation. Specifications subject to change without notification. TEL SPECIFICATIONS hour rate to IEC Rating: Amperes TEL RATINGS Constant Discharge Ratings - 77 F (25 C) /0814/CD 4

5 TEL12-30 (*SLC) SPECIFICATIONS hour rate to IEC Rating: Amperes (*SLC-11 Amps) * TEL12-30 SLC CABLE CONNECTORS ARE RATED FOR ONLY 11 AMPS DISCHARGE 2150 Amperes TEL12-30 & TEL12-30SLC RATINGS Constant Discharge Ratings - 77 F (25 C) TEL12-30SLC Cable TEL12-45SLC CABLE RING TERMINAL.265 I.D..535 O.D. RING TERMINAL BLACK THERMOPLASTIC INSULATED 14 AWG WIRE BLACK THERMOPLASTIC INSULATED 10 AWG WIRE BLACK SHRINK TUBING RED SHRINK TUBING WITH POSITIVE POLARITY SYMBOLS PART NO (32564) BLACK SHRINK TUBING (32647) GREY SHRINK TUBING RED THERMOPLASTIC INSULATED 14 AWG WIRE MOLEX PLUG BLACK SHRINK TUBING RED SHRINK TUBING WITH POSITIVE POLARITY SYMBOLS PART NO (32640) RED THERMOPLASTIC INSULATED 10 AWG WIRE AMP PLUG TEL12-45 (*SLC) SPECIFICATIONS hour rate to IEC Rating: Amperes (*SLC-11 Amps) * TEL12-45 SLC CABLE CONNECTORS ARE RATED FOR ONLY 11 AMPS DISCHARGE 2500 Amperes TEL12-45 & TEL12-45SLC RATINGS Constant Discharge Ratings - 77 F (25 C) /0814/CD 5

6 TEL6-180 SPECIFICATIONS hour rate to IEC Rating: Amperes TEL6-180 RATINGS Constant Discharge Ratings - 77 F (25 C) The above ratings do not include connector voltage drops. Part Number CLEI Number CPR Number TEL PWCYALS1AA TEL 12-30/SLC SLPQ0DU8AA TEL 12-30/CCD PBMB800FRA TEL PWCYALU1AA TEL 12-45/SLC PWCYALV1AA TEL PWCYALW1AA TEL PWCYAMM1AA TEL 12-80/SLC PWCYAMN1AA TEL PWCYALX1AA TEL FS PWCYAUFBAA TEL PWCYALY1AA TEL PWCYALZ1AA

PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

PURE LEAD PLUS UPS APPLICATIONS. Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell UPS 12-1121 PURE LEAD PLUS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications 305-545 Watts per APPLICATIONS Data Centers Network Operations Centers Industrial Process Control

More information

Valve Regulated Lead Acid (VRLA) Battery Series Designed for UPS Standby Power Applications FEATURES & BENEFITS

Valve Regulated Lead Acid (VRLA) Battery Series Designed for UPS Standby Power Applications FEATURES & BENEFITS 12-1079 HIGH RATE MAX UPS 12-355MRF APPLICATIONS Data Centers Network Operations Centers Industrial Process Control Facilities Internet Housing Sites Semiconductor Manufacturing Banks & Financial Markets

More information

FEATURES & benefits. Constant Power Discharge Ratings - Watts per 77 F (25 F) Operating Time (in minutes) to 1.

FEATURES & benefits. Constant Power Discharge Ratings - Watts per 77 F (25 F) Operating Time (in minutes) to 1. -1029 Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications. APPLICATIONS Data Centers Network Operations Centers Industrial Process Control Facilities Internet Housing Sites Semiconductor

More information

PURE LEAD PLUS UPS APPLICATIONS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell

PURE LEAD PLUS UPS APPLICATIONS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications Watts per Cell -11 PURE LEAD PLUS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications 305-545 Watts per Cell FEATURES & benefits APPLICATIONS Data Centers Network Operations Centers Industrial

More information

FEATURES & BENEFITS. 10 year design 25 C

FEATURES & BENEFITS. 10 year design 25 C 41-27 Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications. TECHNICAL DATA FEATURES & BENEFITS 10 year design life @ 25 C Absorbent Glass Mat (AGM) technology for efficient gas

More information

UPS FEATURES & BENEFITS TECHNICAL DATA Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications.

UPS FEATURES & BENEFITS TECHNICAL DATA Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications. 41-9027 Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications. TECHNICAL DATA FEATURES & BENEFITS 10 year design life @ 25 C Absorbent Glass Mat (AGM) technology for efficient gas

More information

SECTION A Division of Exide Technologies

SECTION A Division of Exide Technologies SECTION 22.61 2016-09 A Division of Exide Technologies From the World Leader in VRLA Battery Technology Designed for durability in Telecommunications and Electric Utility applications, the GNB Industrial

More information

SECTION

SECTION SECTION 22.61 2014-03 From the World Leader in VRLA Battery Technology Designed for durability in Telecommunications and Electric Utility applications, the GNB Industrial Power Front Terminal MARATHON

More information

MHR VRLA batteries are manufactured in compliance with TL, NEBS, GR, SR, IEC, BS, UL, ISO, OSHAS and CE quality and performance standards.

MHR VRLA batteries are manufactured in compliance with TL, NEBS, GR, SR, IEC, BS, UL, ISO, OSHAS and CE quality and performance standards. APPLICATIONS UNINTERRUPTIBLE POWER SUPPLY (UPS) SYSTEMS COMMUNICATIONS DATA CENTERS ALTERNATIVE ENERGY The MHR Modular High Rate Valve Regulated Lead Acid batteries feature the latest advancement in plate

More information

Modular Max AGM Range VRLA

Modular Max AGM Range VRLA Innovative Features Valve Regulated Lead Acid (V.R.L.A.) design Fully tank formed plates Never needs addition of water Spill-proof and leak-proof Proprietary Fixed Orifice Plate Pasting technology applying

More information

Modular Max Range BATTERY SOLUTIONS. NEBS qualified. Reliable capacities. EverExceed power your applications

Modular Max Range BATTERY SOLUTIONS. NEBS qualified. Reliable capacities. EverExceed power your applications EverExceed power your applications Modular Max Range BATTERY SOLUTIONS NEBS qualified Reliable capacities CADMIUM FREE FULLY RECYCLABLE LEAD ACID BATTERIES CONFORMS TO THE EUROPEANE.C.1992 DIRECTIVE ON

More information

C&D Technologies, Inc.

C&D Technologies, Inc. C&D Technologies, Inc. WWW.CDTECHNO.COM WWW.CDTECHNO.COM.CN C&D Technologies, Inc. founded in 190, is a leading North America technology company that produces and markets complete, integrated standby power

More information

Deep Cycle AGM Range VRLA

Deep Cycle AGM Range VRLA 01 DEEP CYCLE AGM RANGE 18Ah to 400Ah @ C20 SEALED MONOBLOC AGM BATTERIES The extremely powerful, compact AGM batteries of EverExceed Deep Cycle AGM Range are an ideal energy Source for durability in Photovoltaic,

More information

SECTION

SECTION SECTION 22.60 2011-08 From the World Leader in VRLA Battery Technology Designed for durability in Telecommunications and Electric Utility applications, the TOP Terminal MARATHON series provides high performance

More information

Switchgear Utility specific gravity nominal sulfuric acid. 10 years, full float service at 77 F (25 C)

Switchgear Utility specific gravity nominal sulfuric acid. 10 years, full float service at 77 F (25 C) 12-373 UL Recognized Component RETURN LEAD RECYCLE LIBERTY SERIES 1000 VALVE REGULATED LEAD-CALCIUM BATTERY FOR STANDBY APPLICATIONS Capacities from 100 to 600 Ampere-hours (8 hours to 1.75 VPC) 343 to

More information

AINO MICRO RANGE VRLA. Compact energy for increased security BATTERY SOLUTIONS. EverExceed power your applications

AINO MICRO RANGE VRLA. Compact energy for increased security BATTERY SOLUTIONS. EverExceed power your applications EverExceed power your applications Maintenance free VRLA design Leak proof / Spill proof Gas recombination Absorbed electrolyte Float / Cycle use Low self-discharge rate Reliable one-way safety valve Lead

More information

DataSafe HX Top Terminated Batteries 6 and 12 Volt HX

DataSafe HX Top Terminated Batteries 6 and 12 Volt HX DATASAFE HX TOP TERMINATED BATTERIES DataSafe HX Top Terminated Batteries 6 and 12 Volt HX Available exclusively from EnerSys, the world leader in stored power solutions. DataSafe HX Top Terminated Batteries.

More information

FAT. FAT Battery Range FIAMM.COM

FAT. FAT Battery Range FIAMM.COM FAT FAT Battery Range FIAMM.COM FIAMM FAT RANGE OF VALVE REGULATED BATTERIES HAS BEEN DESIGNED FOR HIGH RELIABILITY AND SAFETY FRONT TERMINAL TELECOM INSTALLATIONS. MAIN APPLICATIONS: FAT BATTERY RANGE

More information

DATA-SHIELD PURE LEAD VRLA UPS BATTERIES

DATA-SHIELD PURE LEAD VRLA UPS BATTERIES DATA-SHIELD PURE LEAD VRLA UPS BATTERIES Pure Lead VRLA Batteries for UPS HBL s range of Data-Shield high rate batteries are designed to provide the highest discharge rates for critical datacenter/ups

More information

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries RS-2046 Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries FOLLOW MANUFACTURER S PUBLISHED INSTRUCTIONS WHEN INSTALLING, CHARGING AND SERVICING BATTERIES.

More information

SPECIFICATIONS. Top Terminal Batteries. SECTION A Division of Exide Technologies

SPECIFICATIONS. Top Terminal Batteries. SECTION A Division of Exide Technologies SPECIFICATIONS Top Terminal Batteries SECTION 22.70 2017-05 A Division of Exide Technologies From the World Leader in VRLA Battery Technology Designed for superior, high-rate performance in uninterruptible

More information

LIBERTY SERIES 1000 VALVE REGULATED LEAD-CALCIUM BATTERY For standby applications Capacities from 25 to 600 Ampere-hours

LIBERTY SERIES 1000 VALVE REGULATED LEAD-CALCIUM BATTERY For standby applications Capacities from 25 to 600 Ampere-hours RETURN RECYCLE 12-373 LEAD LIBERTY SERIES 1000 VALVE REGULATED LEAD-CALCIUM BATTERY For standby applications Capacities from 25 to 600 Ampere-hours UL Recognized Component C&D Technologies Powercom Division

More information

Battery Performance Specifications

Battery Performance Specifications Performance Specifications Features and Benefits range 105-2000Ah Lead-calcium alloy Valve regulated design with recombinant technology eliminates watering requirements Flame retardant polypropylene jar

More information

Features and Benefits

Features and Benefits C&D Tubular GEL (OPzV) Series For Standby & Cyclic Applications C&D Tubular GEL (OPzV) Series range of valve regulated lead acid stationary batteries combine the benefits of recombination technology (i.e.

More information

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries

Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries RS02046 Installation and Operating Procedures For C&D Technologies TRUE Front Access TEL Series Batteries FOLLOW MANUFACTURER S PUBLISHED INSTRUCTIONS WHEN INSTALLING, CHARGING AND SERVICING BATTERIES.

More information

Pure Lead-Tin Technology

Pure Lead-Tin Technology Pure Lead-Tin Technology Pure Lead-Tin technology offers many advantages which include: High overall efficiency High energy density Excellent high rate performance Excellent low temperature performance

More information

EV Traction Dry Cell Battery Technology

EV Traction Dry Cell Battery Technology EV Traction Dry Cell Battery Technology High performance comes standard Superior performance. Engineered to last. RESPONSIBLE Solution Non-gassing and non-spillable Maintenance-free Approved for environmentally

More information

EV Traction Dry Cell Battery Technology

EV Traction Dry Cell Battery Technology EV Traction Dry Cell Battery Technology High performance comes standard Superior performance. Engineered to last. RESPONSIBLE Solution Non-gassing and non-spillable Maintenance-free Approved for environmentally

More information

EV Traction Dry Cell Battery Technology

EV Traction Dry Cell Battery Technology EV Traction Dry Cell Battery Technology High performance comes standard Superior performance. Engineered to last. RESPONSIBLE Solution Nongassing and nonspillable Maintenancefree Approved for environmentally

More information

VRLA Batteries. Battery Installation And Start up Guide

VRLA Batteries. Battery Installation And Start up Guide TECHNICAL MANUAL 41-7525 VRLA Batteries 26-206 Ampere-Hour Capacity Battery Installation And Start up Guide (For Rack Mounted Systems) 41-7525/0514/CD www.cdtechno.com Table of Contents 12V VRLA Battery

More information

Long Duration MCT LEAD CALCIUM H1T LEAD CALCIUM SECTION

Long Duration MCT LEAD CALCIUM H1T LEAD CALCIUM SECTION Long Duration MCT LEAD CALCIUM H1T LEAD CALCIUM SECTION 33.20 2013-09 LONG DURATION MCT LEAD CALCIUM CAPACITIES 190 A.H. TO 480 A.H. 8 HOUR RATE TO 1.75 V.P.C. @ 77 F (25 C) 20 YEAR LIFE EXPECTANCY SPECIFICATIONS

More information

TECHNICAL BULLETIN Fig #1 - VRLA Battery Components. Intercell Welded Connection Strap joining neg. plates in parallel.

TECHNICAL BULLETIN Fig #1 - VRLA Battery Components. Intercell Welded Connection Strap joining neg. plates in parallel. TECHNICAL BULLETIN 41-7264 IntegrIty testing The valve regulated lead acid (VRLA) battery has several components (Ref. Figure 1), all of which can deteriorate with storage conditions and normal as well

More information

CELLYTE 12 PLF & 12PLT Range

CELLYTE 12 PLF & 12PLT Range CELLYTE 12 PLF & 12PLT Range Sealed VRLA Pure Lead Range of Batteries 15 year design life in float service at 25 o C Pure Lead Monobloc batteries using advanced thin pressed plates to provide very high

More information

SECTION

SECTION SECTION 26.10 2008-08 Page 1 2 10 11 9 4 8 4 7 3 1 5 6 Designed for High Performance and Sustainability 1 2 3 4 High capacity in a small footprint. Frees up valuable floor space for other equipment. Jar

More information

SECTION

SECTION SECTION 62.61 2005-07 Page 1 A WORLD LEADER IN VALVE REGULATED LEAD ACID (VRLA) BATTERY POWER FOR PHOTOVOLTAIC AND ALTERNATIVE ENERGY APPLICATIONS Proven Field Experience Since 1983. The Absolyte was developed

More information

1 2 V F T A S E R I E S

1 2 V F T A S E R I E S 1 2 V F T A S E R I E S The future belongs to those who stake a claim for it here and now. This axiom has been our guiding principle at Amara Raja, helping us ceaselessly innovate and explore the new and

More information

SECTION A Division of Exide Technologies

SECTION A Division of Exide Technologies SECTION 26.10 2015-02 A Division of Exide Technologies Page 1 2 10 11 9 4 8 4 7 3 1 5 6 Designed for High Performance and Sustainability 1 2 3 4 High capacity in a small footprint. Frees up valuable floor

More information

PRODUCT GUIDE Publication No: EN-SBS-PG-001 February 2003

PRODUCT GUIDE Publication No: EN-SBS-PG-001 February 2003 PRODUCT GUIDE Publication No: EN-SBS-PG-001 February 2003 Contents Introduction Introduction 2 Range Summary 3 Recombination Technology 4 Construction 5 Features and Benefits 6 Battery Sizing 7-8 Performance

More information

SPA AGM VRLA batteries

SPA AGM VRLA batteries SPA AGM VRLA batteries for Stationary Applications SPA OVERVIEW Valve Regulated AGM batteries The SPA range of SUNLIGHT Valve Regulated Lead Acid batteries has been developed as general purpose batteries,

More information

305/315/355 SERIES CARD EDGE CONNECTOR.156" (3.96mm) Contact Spacing

305/315/355 SERIES CARD EDGE CONNECTOR.156 (3.96mm) Contact Spacing 305/315/355 SERIES CARD EDGE CONNECTOR.156" (3.96mm) Contact Spacing 305/315/355 SERIES ORDERING CODE Example Part Number 305-056 - 521-2 04 Series Total Number of Contacts Contact Code Insulator Style

More information

V R L A HI-PERFORMANCE BATTERIES

V R L A HI-PERFORMANCE BATTERIES V R L A HI-PERFORMANCE BATTERIES The future belongs to those who stake a claim for it here and now. This axiom has been our guiding principle at Amara Raja, helping us ceaselessly innovate and explore

More information

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL 755-00020-DL 5/17/2017 2 755-00020-OEM R01 TABLE OF CONTENTS 1. Important Information About This Manual... 4 1.1 Manual Symbols...

More information

SSLA. SSLA Battery Range FIAMM.COM

SSLA. SSLA Battery Range FIAMM.COM SSLA SSLA Battery Range FIAMM.COM THE SSLA RANGE HAS BEEN DESIGNED TO COVER A WIDE RANGE OF APPLICATIONS. THE FOOTPRINT OF BATTERIES IS ALSO IDEAL FOR CRITICAL INSTALLATIONS. CONNECTION IS SIMPLE ON SMALLER

More information

SSLA. SSLA Battery Range FIAMM.COM

SSLA. SSLA Battery Range FIAMM.COM SSLA SSLA Battery Range FIAMM.COM THE SSLA RANGE HAS BEEN DESIGNED TO COVER A WIDE RANGE OF APPLICATIONS. THE FOOTPRINT OF BATTERIES IS ALSO IDEAL FOR CRITICAL INSTALLATIONS. CONNECTION IS SIMPLE ON SMALLER

More information

SECTION TECHNOLOGIES I NDUSTRIAL E NERGY

SECTION TECHNOLOGIES I NDUSTRIAL E NERGY SECTION 62.61 2009-09 TECHNOLOGIES I NDUSTRIAL E NERGY Page 1 A WORLD LEADER IN VALVE REGULATED LEAD ACID (VRLA) BATTERY POWER FOR PHOTOVOLTAIC AND ALTERNATIVE ENERGY APPLICATIONS Proven Field Experience

More information

341/391 SERIES CARD EDGE CONNECTOR.100" (2.54mm) Contact Spacing

341/391 SERIES CARD EDGE CONNECTOR.100 (2.54mm) Contact Spacing 341/391 SERIES CARD EDGE CONNECTOR.100" (2.54mm) Contact Spacing 341/391 SERIES ORDERING CODE Example Part Number 341-062 - 520-2 02 Series Total Number of Contacts Contact Code Contact Rows Mounting Options

More information

Tubular Gel Technology For Solar Applications

Tubular Gel Technology For Solar Applications Tubular Gel Technology For Solar Applications Website: www.hazebattery.com E mail : sales@hazebattery.com HAZE Tubular Gel Solar Range utilizes proven materials & construction technology tailored for the

More information

PowerStor Standby Battery Systems

PowerStor Standby Battery Systems PowerStor Standby Battery Systems PowerStor Standby Battery Systems PowerStor Standby Battery Systems In today s environment battery systems must perform in the most challenging applications. The versatile

More information

SECTION 26.10C

SECTION 26.10C SECTION 26.10C 2008-08 Page 1 2 10 11 9 4 8 4 7 3 1 5 6 Designed for High Performance 1 High capacity in a small footprint. Frees up valuable floor space for other equipment. 8 Container and Cover - Polypropylene

More information

LIBERTY 2000 SuperMAX For standby applications Capacities from 295 to 2000 Ampere-hours

LIBERTY 2000 SuperMAX For standby applications Capacities from 295 to 2000 Ampere-hours RETURN RECYCLE 12-372 LEAD UL Recognized Component LIBERTY 2000 SuperMAX For standby applications Capacities from 295 to 2000 Ampere-hours C&D Technologies' Powercom Division valve regulated lead-acid

More information

SECTION A Division of Exide Technologies

SECTION A Division of Exide Technologies SECTION 62.61 2015-02 A Division of Exide Technologies Page 1 A WORLD LEADER IN VALVE REGULATED LEAD ACID (VRLA) BATTERY POWER FOR PHOTOVOLTAIC AND ALTERNATIVE ENERGY APPLICATIONS Proven Field Experience

More information

INSTRUCTION MANUAL CAUTION

INSTRUCTION MANUAL CAUTION FILE: IM_091-128-12E-40-115 Rev B., 2-16-2006 INSTRUCTION MANUAL AUTO CHARGE ODY q AUTOMATIC BATTERY CHARGER MODEL #091-128-12E-40-115 for ODYSSEY AGM BATTERIES CAUTION This charger is calibrated to the

More information

INSTRUCTION MANUAL. Maintenance-free Absorbent Glass Mat technology and valve-regulated batteries. (AGM / VRLA)

INSTRUCTION MANUAL. Maintenance-free Absorbent Glass Mat technology and valve-regulated batteries. (AGM / VRLA) INSTRUCTION MANUAL Maintenance-free Absorbent Glass Mat technology and valve-regulated batteries. (AGM / VRLA) DESCRIPTION / TYPE: SUN BATTERY Nominal values Nominal voltage UN: 2V Cells 6V Blocks 12V

More information

PS-Series General Purpose Batteries

PS-Series General Purpose Batteries PS-Series General Purpose Batteries All PS Series batteries feature: Absorbent Glass Mat (AGM) technology for superior performance. Valve regulated, spill proof construction allows safe operation in any

More information

BR62 Battery Rack Installation, Operation, & Maintenance Manual

BR62 Battery Rack Installation, Operation, & Maintenance Manual BR62 Battery Rack Installation, Operation, & Maintenance Manual 8/28/2012 2 755-00046 R02 Copyright 2012 C&C Power, Inc. All rights reserved. C&C Power, Inc. 395 Mission Street Carol Stream, IL 60188 www.ccpower.com

More information

Pallet Pro On-Board Power System and 6 Volt Group 27 Deep Cycle Bloc Batteries GB A Division of Exide Technologies

Pallet Pro On-Board Power System and 6 Volt Group 27 Deep Cycle Bloc Batteries GB A Division of Exide Technologies Pallet Pro On-Board Power System and 6 Volt Group 27 Deep Cycle Bloc Batteries GB4086 2015-02 A Division of Exide Technologies Element Pallet Pro On-Board Power System Application The Pallet Pro is an

More information

PERFORMANCE SPECIFICATIONS

PERFORMANCE SPECIFICATIONS PERFORMANCE SPECIFICATIONS Introducing the PowerSafe DDm Range The PowerSafe DDm range of valve regulated lead acid batteries further demonstrates EnerSys' commitment to supplying those high quality products

More information

Haze Battery Company Ltd. Sealed Lead Acid 2 Volt Bloc. Gelled Electrolyte Range

Haze Battery Company Ltd. Sealed Lead Acid 2 Volt Bloc. Gelled Electrolyte Range Haze Battery Company Ltd Sealed Lead Acid 2 Volt Bloc Gelled Electrolyte Range CONSTRUCTION - Gel battery construction is as shown in the diagram. The positive and negative grids are cast from a calcium/tin

More information

Industrial Batteries Network Power Powerfit S500 High energy density for maximum security. Specifications

Industrial Batteries Network Power Powerfit S500 High energy density for maximum security. Specifications Industrial Batteries Network Power Powerfit S500 High energy density for maximum security. Specifications If cost efficiency and high performance are requested. Specifications Especially designed for safety

More information

FlexCharger Battery Chargers

FlexCharger Battery Chargers FlexCharger Battery Chargers Operating Instructions Definitions (as used in these instructions) Flooded Battery Lead-acid battery with liquid electrolyte that requires open-venting and regular water replacement.

More information

UPS FEATURES & BENEFITS C&D Technologies flooded batteries are engineered to provide superior performance

UPS FEATURES & BENEFITS C&D Technologies flooded batteries are engineered to provide superior performance 12-1023 All Batteries Capacity tested to 100% H LEAD CALCIUM BATTERIES FOR UPS AND SWITCHGEAR APPLICATIONS CAPACITIES FROM 0.370 TO 7.523 KILOWATTS PER CELL L W C&D Technologies flooded batteries are engineered

More information

Product Guide. An Invensys company

Product Guide. An Invensys company Product Guide An Invensys company Contents Page I/ The principle of the gas-recombination battery... 2 II/ Charge characteristics... 4 III/ Electrical performance tables... 5 IV/ Battery calculations Float

More information

Chapter 3. Direct Current Power. MElec-Ch3-1

Chapter 3. Direct Current Power. MElec-Ch3-1 Chapter 3 Direct Current Power MElec-Ch3-1 Overview Batteries Safety Precautions Marine Storage Battery Charging Systems Battery Utilization MElec-Ch3-2 Batteries Cells and Battery Battery Chemistry Primary

More information

SVTX AGM VRLA batteries

SVTX AGM VRLA batteries SVTX AGM VRLA batteries 2 Energy is what we do SVTX batteries introduction Product Information The SVTX range of SUNLIGHT Valve Regulated Lead Acid batteries has been designed to provide superior performance

More information

XHP. Low maintenance high performance batteries

XHP. Low maintenance high performance batteries Low maintenance high performance batteries Range Low maintenance, high performance Ni-Cd batteries Powerful assurance for critical applications Depend upon where vital UPS, engine starting and emergency

More information

Haze Battery Company Ltd

Haze Battery Company Ltd Haze Battery Company Ltd Sealed Lead Acid 2 Volt Bloc Gelled Electrolyte Range CONSTRUCTION - Gel battery construction is as shown in the diagram. The positive and negative grids are cast from a calcium/tin

More information

Multilink Transportation Power Solutions

Multilink Transportation Power Solutions Multilink Transportation Power Solutions For Traffic, Intelligent Transportation Systems (ITS), Surveillance and Security Applications MULTILINK IS THE CHOICE WHEN SAFETY MATTERS. GoMultilink.com GoMultilink.com.

More information

2 Volt AGM Range. Haze Battery Company Ltd

2 Volt AGM Range. Haze Battery Company Ltd 2 Volt AGM Range Haze Battery Company Ltd Q Q M M The Haze HZB - AGM range covers Ah capacities from 50Ah to 3850Ah (C10) with dimensions suitable for racking systems for maximum space utilisation. Specially

More information

SUBSTATION EQUIPMENT - Page 1 of 8

SUBSTATION EQUIPMENT - Page 1 of 8 BATTERY BANKS 1. GENERAL: JEA utilizes a 125 volt DC system for the control and operation of its transmission and distribution substations. JEA has standardized on lead acid type battery banks to supply

More information

Chapter 6. Batteries. Types and Characteristics Functions and Features Specifications and Ratings Jim Dunlop Solar

Chapter 6. Batteries. Types and Characteristics Functions and Features Specifications and Ratings Jim Dunlop Solar Chapter 6 Batteries Types and Characteristics Functions and Features Specifications and Ratings 2012 Jim Dunlop Solar Overview Describing why batteries are used in PV systems. Identifying the basic components

More information

Industrial Batteries / Network Power. Sprinter P / XP.»Reliable power for increased ed security«

Industrial Batteries / Network Power. Sprinter P / XP.»Reliable power for increased ed security« Industrial Batteries / Network Power»Reliable power for increased ed security« Network Power > Product overview Industrial Batteries The powerful range of Network Power Energy storage solutions for critical

More information

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2 DESCRIPTION AND FEATURES... 3 CHARGING STAGES... 4 Art. No. EC-315 Art. No. EC-330 Art. No. EC-340 PROTECTIONS... 5 INSTALLATION...

More information

Industrial Batteries / Network Power. Marathon L / XL.»More energy for safer storage«

Industrial Batteries / Network Power. Marathon L / XL.»More energy for safer storage« Industrial Batteries / Network Power»More energy for safer storage«« Network Power > Product overview Industrial Batteries The powerful range of Network Power Energy storage solutions for critical systems

More information

UZB GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY REPLACEMENT BATTERY REPLACEMENT 12V, 12AH 1/6.

UZB GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY REPLACEMENT BATTERY REPLACEMENT 12V, 12AH 1/6. U-Series BATTERY REPLACEMENT Maintenance-free VRLA Lead-Acid Battery AGM (Absorbent Glass Mat) Technology Can Be Installed in Any Orientation Except Permanently Inverted 1. GENERAL DESCRIPTION The is a

More information

NorthStar Battery Company DCN: SES DCR: 1548-S09 Date:

NorthStar Battery Company DCN: SES DCR: 1548-S09 Date: Application Manual and Product Information for NorthStar Battery Company Table of Contents Introduction...3 NSB Blue Series Benefits...4 ISO Certifications...5 NSB Blue Product Specifications...6 Leak

More information

BATTERIES BATTERIES VRLA / SLA / GEL 2V/6V/12V. DP Electronics e.k (Deutsche Power Co., Limited)

BATTERIES BATTERIES VRLA / SLA / GEL 2V/6V/12V. DP Electronics e.k (Deutsche Power Co., Limited) BATTERIES BATTERIES VRLA / SLA / GEL 2V/6V/12V VRA / SLA BATTERIES AGM (2V, 12V Cell) Durable and Power Full Batteries A VRLA battery (valve-regulated lead-acid battery) more commonly known as a sealed

More information

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc Haze Battery Company Ltd Sealed Lead Acid 6 & 12 Volt Monobloc AGM Range CONSTRUCTION - AGM battery construction is as shown in the diagram below. The positive and negative grids are cast from a calcium

More information

FIAMM Industrial Batteries December 2012 FIAMM AGM Valve Regulated Recombination Batteries: FLX Series- Engineering Manual TABLE OF CONTENTS

FIAMM Industrial Batteries December 2012 FIAMM AGM Valve Regulated Recombination Batteries: FLX Series- Engineering Manual TABLE OF CONTENTS TABLE OF CONTENTS PAGE 1 OPERATING CHARACTERISTICS 2 2 INSTALLATION 4 3 CHARGING 6 4 STORAGE AND REFRESH CHARGING 8 5 MAINTENANCE AND TESTING 9 6 SAFETY 10 7 APPLICABLE STANDARDS 10 8 RECORDS DATA 10 FIAMM.

More information

OSP Battery Training. Craig Paoli Director Strategic Platforms July 13 th Copyright 2010 The Alpha Group. All Rights Reserved.

OSP Battery Training. Craig Paoli Director Strategic Platforms July 13 th Copyright 2010 The Alpha Group. All Rights Reserved. OSP Battery Training Craig Paoli Director Strategic Platforms July 13 th 2013 Copyright 2010 The Alpha Group. All Rights Reserved. Topics: Types of lead acid batteries o VLA vs. VRLA o AGM vs. Gel o Standby

More information

Product Guide. An Invensys company

Product Guide. An Invensys company Product Guide An Invensys company Contents Introduction Introduction 2 Range Summary 3 Technology 4 Construction 5 Selection of Battery Size 6 Performance Data 7-26 Operating Characteristics 27 Operating

More information

Industrial Batteries / Network Power. Marathon M FT.»AGM modular power«

Industrial Batteries / Network Power. Marathon M FT.»AGM modular power« Industrial Batteries / Network Power»AGM modular power« Network Power > Product overview Industrial Batteries The powerful range of Network Power Energy storage solutions for critical systems that require

More information

Industrial Batteries / Network Power. Marathon M-FT.»AGM modular power«

Industrial Batteries / Network Power. Marathon M-FT.»AGM modular power« Industrial Batteries / Network Power»AGM modular power« Network Power > Product overview Industrial Batteries The powerful range of Network Power GNB Industrial Power offers reliable energy storage solutions

More information

Valve regulated Batteries for Stationary Applications. HAGEN dc plus. An EXIDE Company

Valve regulated Batteries for Stationary Applications. HAGEN dc plus. An EXIDE Company Valve regulated Batteries for Stationary Applications HAGEN dc plus An EXIDE Company The new! HAGEN dc plus The new battery generation dc plus is based on the proven flat plate series HAGEN drysafe compact.

More information

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc

Haze Battery Company Ltd. Sealed Lead Acid 6 & 12 Volt. AGM Range. Monobloc Haze Battery Company Ltd Sealed Lead Acid 6 & 12 Volt Monobloc AGM Range CONSTRUCTION - AGM battery construction is as shown in the diagram below. The positive and negative grids are cast from a calcium

More information

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT: READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL. KEEP IT WITH OR NEAR CHARGER AT ALL TIMES.

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT: READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL. KEEP IT WITH OR NEAR CHARGER AT ALL TIMES. IMPORTANT SAFETY INSTRUCTIONS IMPORTANT: READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL. KEEP IT WITH OR NEAR CHARGER AT ALL TIMES. SPECIFICATIONS: For technical assistance, call your Dealer with the

More information

Industrial Batteries Standby Power Marathon L Reliable and safe energy in long-term storage. Specifications

Industrial Batteries Standby Power Marathon L Reliable and safe energy in long-term storage. Specifications Industrial Batteries Standby Power Marathon L Reliable and safe energy in long-term storage. Specifications This well-proven battery system guarantees safety at all times. Specifications Marathon L provides

More information

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

ST - II Series POWER SUPPLIES USER INSTRUCTIONS Introduction ST - II Series POWER SUPPLIES These instructions detail the installation and operation requirements for the ST20-II & ST35-II power supplies. These have been designed for operation in RV s

More information

Industrial Batteries / Network Power. Marathon M FT.»AGM modular power«

Industrial Batteries / Network Power. Marathon M FT.»AGM modular power« Industrial Batteries / Network Power»AGM modular power« Network Power > Product Overview Industrial Batteries The strong range of Network Power Energy storage solutions for critical systems that require

More information

SECTION 26.10C A Division of Exide Technologies

SECTION 26.10C A Division of Exide Technologies SECTION 26.10C 2015-02 A Division of Exide Technologies Page 1 2 10 11 9 4 8 4 7 3 1 5 6 Designed for High Performance 1 High capacity in a small footprint. Frees up valuable floor space for other equipment.

More information

Batteries for HTM. D. J. McMahon rev cewood

Batteries for HTM. D. J. McMahon rev cewood Batteries for HTM D. J. McMahon 141004 rev cewood 2017-10-09 Key Points Batteries: - chemistry; know the characteristic cell voltages of common chemistries: NiCd/ NiMH 1.2V Hg 1.35V Zn Alkaline 1.5V Ag

More information

NCPP. Nickel Cadmium Pocket Plate Batteries. Block Cell Dimensional and Electrical Data

NCPP. Nickel Cadmium Pocket Plate Batteries. Block Cell Dimensional and Electrical Data NCPP Nickel Cadmium Pocket Plate Batteries Block Cell Dimensional and Electrical Data Nickel Cadmium Pocket Plate Batteries HBL's Nickel Cadmium Pocket Plate Battery designs are based on the superior Pocket

More information

Valve Regulated Pocket Plate Nickel Cadmium Battery. Technical Manual

Valve Regulated Pocket Plate Nickel Cadmium Battery. Technical Manual Valve Regulated Pocket Plate Nickel Cadmium Battery Technical Manual Contents Pages 1.0. Introduction to VRPP battery 2.0. VRPP - Solution to varied applications 3.0. xygen recombination cycle - A technological

More information

Lightweight, On-Board, Power Tender: Models: 12V6A, 24V3A

Lightweight, On-Board, Power Tender: Models: 12V6A, 24V3A Lightweight, On-Board, Power Tender: Models: 12V6A, 24V3A The Tender Light Weight On- Board 12 Volt, 6 Amp 24 Volt, 3 Amp GENERAL DESCRIPTION: The lightweight, on-board, power tender, battery charger is

More information

Power to keep you on the move

Power to keep you on the move Power to keep you on the move Electric Vehicle Gel ELECTRIC VEHICLE applications are wide and varied with many durability & power demands placed firmly on the batteries shoulders. HAZE ELECTRIC VEHICLE

More information

Sealed Lead-Acid Batteries

Sealed Lead-Acid Batteries Sealed Lead-Acid Batteries FEATURES Sealed/Maintenance-Free The valve regulated, spill-proof construction of the Power-Sonic battery allows trouble-free, safe operation in any position. There is no need

More information

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS ASSOCIATED OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS MODEL 6366 12 VOLT, 0-20 AMP 4 X 20 BATTERY CHARGER 1. SAVE THESE INSTRUCTIONS. This manual contains important safety and operating instructions

More information

Standby Products SD-SDH. series. Technical Features. Applications. Product Features

Standby Products SD-SDH. series. Technical Features. Applications. Product Features SD-SDH series The FIAMM s SD-SDH battery range can be used in standby mode for duties requiring high performance and reliability. The SD-SDH family is specially designed for discharge rates that are required

More information

FLOODED (VLA ), SEALED (VRLA), GEL, AGM TYPE, FLAT PLATE, TUBULAR PLATE: THE WHEN, WHERE, AND WHY. HOW DOES THE END USER DECIDE ON THE BEST SOLUTION?

FLOODED (VLA ), SEALED (VRLA), GEL, AGM TYPE, FLAT PLATE, TUBULAR PLATE: THE WHEN, WHERE, AND WHY. HOW DOES THE END USER DECIDE ON THE BEST SOLUTION? BATTCON 2006 FLOODED (VLA ), SEALED (VRLA), GEL, AGM TYPE, FLAT PLATE, TUBULAR PLATE: THE WHEN, WHERE, AND WHY. HOW DOES THE END USER DECIDE ON THE BEST SOLUTION? Dr. Wieland Rusch Keith Vassallo Gary

More information

INSTRUCTIONS FOR CONTINUED AIRWORTHINESS COMPONENT MAINTENANCE MANUAL CONCORDE VALVE REGULATED LEAD-ACID RG-441 BATTERY AUTHORISED UNDER TSO-C173

INSTRUCTIONS FOR CONTINUED AIRWORTHINESS COMPONENT MAINTENANCE MANUAL CONCORDE VALVE REGULATED LEAD-ACID RG-441 BATTERY AUTHORISED UNDER TSO-C173 INSTRUCTIONS FOR CONTINUED AIRWORTHINESS COMPONENT MAINTENANCE MANUAL CONCORDE VALVE REGULATED LEAD-ACID RG-441 BATTERY AUTHORISED UNDER TSO-C173 The data/information contained herein has been reviewed

More information

Batteries for HTM. Basic Battery Parameters:

Batteries for HTM. Basic Battery Parameters: Batteries for HTM Key Points Batteries: - chemistry; know the characteristic cell voltages of common chemistries: NiCd/ NiMH 1.2V Hg 1.35V Zn Alkaline 1.5V Ag Oxide 1.55V Pb 2.0V Li 3.0V LiIon/ LiPo 3.6V

More information