1 Operating Instructions Electric Vibrators Models Single and Three Phase QT-80 DEG-6 QT-60 DEG-45 QT-50 DEG-90 QT-500 DEG-0 QT-000 DEG-50 DEG-50 DEG-5000 DEG-5 Global Manufacturing Inc. 80 East nd St Little Rock, Arkansas TEL TOLL FREE USA & CANADA FAX QT_05/5/0 rev COPYRIGHT 00 - Global Manufacturing, Inc

2 Table of Contents Safety Precautions I. Operation 4 Page II. Installation Procedures 4-6 III. Mounting Locations 7 IV. Channel Iron Dimensions 8 Mount Plate Dimensions 8 Vibrator Bolts & Required Torque 8 V. Electrical Information and Wiring Diagrams 9-4 Heater sizes for Allen Bradley Overload Protectors 9 DEG-6, 45, 90, & QT-000 5V PH 60 Hz 0 DEG-6, 45, 90, & QT-000 0V PH 60 Hz 0 QT-50, 500 5V PH 60Hz QT-50, 500 0V PH 60Hz QT-50, 500, 000, DEG-6, 45, 90, 0, 50, 50, 5000,5 0V PH 60Hz QT-50, 500, 000, DEG-6, 45, 90, 0, 50, 50, 5000, 5 460V PH 60Hz DEG-60, 900, 00, 00, V and 45V PH 50 Hz DEG-6, 45, 90, 0, 50, 50, 500, 5 575V PH 60 Hz VI. Leading Causes of Electric Vibrator Failure 4 VII. Setting Adjustments 4-7 VIII. Dimensions 8-9 IX. Performance Data 0 X. Voltage and Amp Draw Information XI. Troubleshooting

3 SAFETY PRECAUTIONS Follow wiring and installation wiring instructions. A licensed electrician should adhere to all electrical codes when wiring three phase and direct wired single phase vibrators. Take amperage and voltage readings upon completion of installation. See pages 0 - for run and start amp draws for each vibrator and page for more information on voltage drops. High amperage reading means something is wrong and the vibrator may be damaged or not mounted properly. Operate a -phase unit with proper overload protection. Failure to comply voids warranty. For single-phase, use properly grounded -prong receptacle and do not use an extension cord without knowing the voltage drop in order to use the correct gauge size. See page for instructions on how to calculate what size of extension cord you should use. Make sure all electrical connections are secure and will not vibrate loose. Follow all mounting instructions. Bolt vibrator to a flat surface, across a long vertically oriented channel iron flush to the outside of the hopper wall. Contact factory if you are unable to closely follow all installation instructions or if amperage readings are high. Attach a safety cable or chain from vibrator to an independent stronghold. Prior to use, check vibrator for damage (twisted unit, cracked junction box, loose wires, missing end covers, etc.) Do not operate a damaged vibrator. Maximum ambient operating temperature is 04 F (40 C). Do not mount electrical control boxes onto structure (bin/hopper) wall to be vibrated. Do not operate vibrators when structure is empty. Do not operate vibrators when gate is closed or conveyor is stopped unless consolidation of material is desired. Wear ear protection for 90+ decibel levels. Do not operate vibrators without side covers. Always disconnect electricity before maintenance. Follow OSHA regulation Section for lockout program.

4 I. OPERATION These electric vibrators are built for continuous duty, however the vibrators may be cycled on and off for intermittent duty. The minimum time between consecutive starts is two () minutes. Each time the vibrator starts it draws high amperage, therefore allow vibrator to cool or run for two minutes before starting again. Do not operate the vibrator on an empty hopper. The vibration will vibrate the hopper and the vibrator causing damage if no bulk material is present. When the vibrator is mounted rigidly the vibration will pass through the structure and resonate the material inside the hopper. Operate vibrators when discharge gates are open unless compaction of material is desired. The vibrator should appear motionless. Guidelines for all three phase models: 6. Direction of rotation for three phase vibrators cannot be set at the factory. 7. Remove draw bolts or round head screws from unit and pry off the weight cover. 8. Bump the starter just long enough to determine the direction of rotation. 9. If rotation is incorrect, switch connections on any two legs of the circuit. 0. Replace weight covers and draw bolts or screws. Tighten screws securely. Torque draw bolts to value indicated in the weight adjustment section - pages 4-7. II. INSTALLATION PROCEDURES The key to successful vibration is the proper installation of the vibrator. DEG Single Phase Models Figure The eccentric weights, which are found on the end(s) of the motor shaft, should rotate toward the desired direction of material flow. In hopper applications, the weights should rotate towards the bin wall and down. Guidelines for the all single phase models: Safety Cable Junction Box Mount Plate. QT-80-: Mount vibrator with motor on left side - Figure.. QT-60-: Mount vibrator with capacitor on top - Figure.. QT-50- and QT-500-: Mount with motor on right side - Figure QT-000-: Mount vibrator with junction box located on the upper left side - Figure All single phase DEG models: Mount vibrator with junction box located on the upper left side - Figure. Loop electric cord 0 - to allow flexibility. Clamp cord to prevent pulling. Protect cord with grommet. 4

5 QT-80- QT-60- Figure Figure Safety Cable Mount Plate Capacitor Leave slack in cord to allow flexibility Leave slack in cord to allow flexibility Clamp cord to prevent pulling Protect cord with grommet Clamp cord to prevent pulling Protect cord with grommet QT-50- QT-500- Figure 4 QT-000- Figure 5 Junction Box Leave slack in cord to allow flexibility Safety Cable Safety Cable Junction Box Mount Plate Leave slack in cord to allow flexibility Motor Clamp cord to prevent pulling. Protect cord with grommet. Clamp cord to prevent pulling. Protect cord with grommet. 5

6 Caution! Do not mount the vibrator directly to the structure wall. Use a channel iron stiffener for proper mount rigidity and as the transducer of the vibrational energy. The key to successful vibration is a proper mount because rotary vibration resonates the material inside the structure. The vibrator should appear motionless. There should not be a large amount of motion or noise. Follow the instructions on how to mount the vibrator and you will get great results. Important! Channel Iron with Piggy-back Channel Do not weld the ends of the channel iron. This allows the vibrational force to escape. Solid welded ends trap the force, which can cause stress cracks. Channel Iron with Mount Plate Skip weld along back side of plate Length of Channel Piggy-back channel Do not weld the ends of plate to channel Stitch weld channel iron Width of Channel The channel iron should be at least two-thirds of the height of the sloped portion of the hopper but no greater than 0 feet ( m). Channel Irons - How to Mount The channel iron should be at least two-thirds the height of the sloped portion of the hopper, but not less than 6 (.8 m) or greater than 0 ( m) in length. The channel iron width should not be less than the base width of the vibrator. However, a mount plate of / to /4 (.7 to 9.05 mm) thick, sized to fit the foot pattern of the vibrator, may be skip welded to the channel. The mount plate must allow the vibrator to sit FLAT on the plate with no detectable rocking. If the vibrator does not sit flat, the plate may be warped. Shim the vibrator prior to mounting to compensate for any warping. See Table on page 8 for recommended channel iron and mount plate sizes. DO NOT install more than one vibrator on the same channel iron or use a channel iron shorter than the recommended length. A short channel may flex the bin wall. Attach the vibrator to the channel iron. Stitch weld nuts to the back of the channel iron or the channel iron may be drilled and tapped to accept the mounting bolts. An alternate method is to cut a second channel iron slightly longer than the footprint of the vibrator. Stitch weld the second channel iron to the first. Do not weld the ends. Mount the vibrator to the second channel iron. 6 Weld along the length of the channel on back side of plate. Do not weld across the width of channel. Place vibrator on top of mount plate Stitch weld the channel iron vertically to the slope portion of the bin wall. Weld inches (7.5 cm), skip inch (.5 cm), weld inches (7.5 cm), etc... Leave inch (.5 cm) un-welded on the ends and corners. This allows the vibration to dissipate out the ends of channel without causing stress cracks to the hopper or bin. By doing so, should the weld fail, the entire mount will not fall off. Do not mount the channel iron horizontally. Secure the vibrator to the channel iron with SAE coarse thread grade 8 plated bolts with lock washers or an adhesive such as Loctite 6. Tighten bolts in a sequential process. At least two passes are required in most situations. Give all bolts the same torque value. Grade 8 bolts can handle more torque than standard bolts. If Loctite is not used, torque the bolt after the vibrator has operated for a few minutes and check tightness often. If Loctite is used do not torque the bolts a second time as this will break the Loctite bond. Attach a safety cable to a stronghold (not the channel iron mount), which is higher than the mounted vibrator and capable of holding the vibrator s weight.

7 III. MOUNTING LOCATIONS Single Vibrator Install a channel iron stiffener on the outside of the sloping wall / the distance above the discharge opening. Multiple Vibrators Use more than one vibrator when the diameter or width of any wall is greater than feet (.66 m). Always mount the vibrators on different planes. Two Vibrators on Round or Square Hoppers Install channel iron stiffeners 80 apart. Install one vibrator on the outside of the sloping wall / the distance above the discharge opening. Install the second vibrator on the outside of the opposite sloping wall / the distance above the discharge opening. H / of H / of H / of H / of H Three Vibrators Install channel iron stiffeners mounted 0 apart. Install the first vibrator on the outside of the sloping wall /4 the distance above the discharge opening. Install the second vibrator on a separate channel iron at / the distance above the discharge opening. Install the third vibrator on the remaining channel iron at /4 the distance above the discharge opening. H / of H / of H Two Vibrators on Rectangular Hoppers Install channel iron stiffeners on opposite sides of the long walls. Install one vibrator on the outside of the sloping wall / the distance from the discharge opening. Install the second vibrator on the outside of the opposite sloping wall / the distance above the discharge opening. When only one wall slopes, mount both stiffeners on it. Equally space the stiffeners on the wall. Place one vibrator / above the discharge opening on one channel iron and the other vibrator / above the bin s discharge opening on the second channel. / of H / of H Installation on Chutes and Flow Pipes Mount channel iron stiffeners vertically or in the direction of material flow. Center the channel if the chute is less than 6 feet (.8 m) in width. If the chute is greater than 6 feet in width, use two vibrators on separate channel irons. To maximize each vibrator s radius of influence; center each channel iron in each half of the chute. Each channel iron should be located ¼ of the chute width from the edge and ½ of the chute width apart. (e.g. for a chute 8 wide, the channel iron locations would be from each edge and 4 apart.) When wall thickness is less than /8, additional reinforcement may be required. Width is more than 6 H /4 of H ¼ of Width /4 of H / of H ½ of Width ¼ of Width 7

8 IV. CHANNEL IRONS, MOUNT PLATES, AND BOLT SIZES Vibrator Model - and Phase QT-80 QT-60 QT-50, QT-500, QT-000 DEG-6, DEG-45, DEG-90 DEG-0, DEG0-00, DEG-50, DEG-50,DEG-5000, DEG-5 Channel Iron Dimensions for Electric Vibrators Width Minimum Web Thickness Minimum Length Per Length inch inch feet lb/ft mm mm mm kg/m Make channel iron length at least / the height of the slope section of the bin without exceeding 0 ( M) in length. Vibrator Model and Phase QT-60 QT-000 DEG-6, DEG-45, DEG-90 Mount Plate Dimensions for Electric Vibrators DEG-0, DEG-00, DEG-50, DEG-50, DEG-5000, DEG-5 Width Length Minimum Thickness inch inch inch mm mm mm / / / / Skip weld along back side of plate Length of Channel Do not weld the ends of plate to channel Weld along the length of the channel on back side of plate. Do not weld across the width of channel. Width of Channel Place vibrator on top of mount plate 8 Vibrator Bolts and Required Torque - Single and Three Phase Model Bolt Torque QT-80, QT-60 /8-6 UNC Grade 8 Plated lb-ft (45 N-m) QT-50, QT-500, QT-000 / - UNC Grade 8 Plated 80 lb-ft (07 N-m) DEG-6, DEG-45, DEG-90 / - UNC Grade 8 Plated 80 lb-ft (07 N-m) DEG-0, DEG-00, DEG-50, DEG-50, DEG-5000 /4-0 UNC Grade 8 Plated 8 lb-ft (8 N-m) DEG-5 /4-0 UNC Grade 8 Plated 8 lb-ft (8 N-m)

9 Placement on Channel Iron The axis of rotation of the eccentric weights for all rotary vibrators should be oriented in the direction of material flow. The shaft of the vibrator should ideally be in a horizontal position to prolong bearing life. Heater Size for Allen Bradley Overload Protectors Vibrator Model Volts Phase Amps - Max Run (Start) Heater Size QT () N/A QT (.8) N/A Direction of Material Flow QT-50- QT-500- QT-000- QT (9) N/A 0. (6) N/A 5.6 (9) N/A 0. (.6) N/A (4) N/A 0. () N/A 0 8 () W (.5) W-7 QT () W (.5) W-7 V. WIRING ELECTRIC VIBRATORS Only a qualified electrician should connect the wiring of an electric vibrator. All three phase electric vibrators must have overload protection to validate warranty. Using the wrong voltage, phase, or wire size will damage the vibrator and void the warranty. Measure the amperage on all legs after installing the vibrator. If the amperage draw is higher than specified on the motor nameplate, turn the vibrator off. High amperage draw may be due to improper mounting of the vibrator, low voltage, or incorrect voltage. Most of the single and three phase vibrators have a dual voltage motor which can be wired for either 5V/0V and 0V/460V. Simply change the wire connections in the junction box. Exceptions: The 575V DEG models, the QT-80- and QT-60- single voltage motors cannot be wired for a different voltage. The three phase vibrators are supplied with overload protection. See chart in next column for recommended size of heater to use with Allen- Bradley overload protectors. Other brands of equal rating may be used, but never use a higher rated heater. If the wrong overload protection is used the warranty will be void. QT-000- DEG-6- DEG-45- DEG-90- DEG-6- DEG-45- DEG-90- DEG-0- DEG-50- DEG-50- DEG (.5) W () W (44) N/A 0.4 () N/A (7) W (8) W (8) W- 0.8 () W () W (8) W-7 DEG (4) W- DEG () W (6) W () W- Sizes shown are Allen-Bradley brand heaters. 9

10 5 Volt - Single Phase 60 Hertz Model # Part # Amps-Max Run (Start) DEG (44) 4 Yellow 5 Terminal Yellow P.N X DEG (44) DEG (44) QT (4) Terminal Red P.N Electronic Start Solid State Switch P.N.4508 Terminal Ring P.N Yellow Cord Restraint /" P.N Neutral Green 5 Electric Cord 6/ P.N.4506 Side Motor Side 0 Volt - Single Phase 60 Hertz Model # Part # Amps-Max Run (Start) 4 Yellow 5 DEG () DEG () Terminal Yellow P.N x DEG () QT () Terminal Red P.N Electronic Start Solid State Switch P.N Terminal Ring P.N Cord Restraint /" P.N Neutral Green Yellow 5 Electric Cord 6/ P.N.4506 Side Wire Nut P.N Motor Side 0

11 5 Volt - Single Phase 60 Hertz Model # Part # Amps-Max Run (Start) QT (7) QT (9) 4 Yellow Terminal Yellow P.N X Purple Terminal Red P.N Purple Cord Restraint /" P.N Electric Cord 6/ P.N.4506 Electronic Start Solid State Switch P.N.4508 Neutral Green Terminal Ring P.N Yellow Side Motor Side 0 Volt - Single Phase 60 Hertz Purple Model # Part # Amps-Max Run (Start) Purple QT (6) QT (6) Electronic Start Solid State Switch P.N.4508 Terminal Red P.N x Terminal Ring P.N Wire Nut P.N x Neutral Green 4 Yellow Cord Restraint /" P.N Electric Cord 6/ P.N.4506 Side Motor Side

12 0 Volt - Three Phase 60 Hertz Model # Part # Amps-Max Run (Start) QT () QT () QT (.5) DEG (7) DEG (7) DEG (7) DEG () DEG () DEG () DEG () DEG () Junction Box 9 Gray Cord Restraint /" P.N Purple 9 Gray 5 8 Red 0 VAC Phase 60 Hz 8 Red Red 4 Yellow 7 Pink Red Wire Nut P.N x 5 6 Purple 4 Yellow 7 Pink Neutral Green Electric Cord 6/4 P.N.4500 Terminal Ring P.N Side Motor Side 460 Volt - Three Phase 60 Hertz Model # Part # Amps-Max Run (Start) QT (.5) QT (.5) QT () DEG (8) DEG (8) Junction Box Wire Nut P.N x 9 Gray 6 Purple 8 Red 5 6 Purple 9 Gray 5 8 Red 4 Yellow 7 Pink 460V Phase 60 Hz Red DEG (8) DEG () DEG () 7 Pink 4 Yellow DEG () DEG () DEG (6) Cord Restraint /" P.N Red Neutral Green Terminal Ring P.N Electric Cord 6/4 P.N.4500 Side Motor Side

13 575 Volt - Three Phase 60 Hertz Model # Part # Amps-Max Run (Start) DEG (4) DEG (4) DEG (4) DEG (8) DEG (8) DEG (8) DEG (8) DEG () 80 & 45 Volt - Three Phase 50 Hertz Model # Part # Amps-Max Run (Start) DEG (7) DEG (7) DEG () DEG () DEG () Wire Nut P.N x Junction Box Cord Restraint /" P.N Red Neutral Green Electric Cord 6/4 P.N.4500 Side Terminal Ring P.N Motor Side

14 VI. THREE LEADING CAUSES OF ELECTRIC VIBRATOR FAILURE ) Single Phasing: A leading cause of failure in three phase motors is losing one of the three phases, called single phasing. Single phasing can be caused by blowing only one of the three fuses that protect the circuit, by a faulty contact in the motor starter, by losing a phase from the local electric utility, and numerous other ways. A vibrator that burns up due to single phasing is not covered under warranty. While heaters do an excellent job of protecting a motor from overload conditions, they often do not protect a three phase motor from single phasing. Global Manufacturing strongly recommends using a motor starter that is designed to detect a missing phase. The Furnas ESP00 series is a heaterless design which detects phase loss in seconds and shuts the motor off. ) Low Voltage: Another failure point is low voltage caused by high starting current. An electric vibrator will take to seconds to reach full running speed. During this starting period, the vibrator draws more current than it draws at full running speed. The high starting current may cause the voltage to sag or drop below 80% of the rated voltage when measured at the vibrator. If inadequate voltage is provided initially, a voltage drop will cause problems. Low voltage may prevent the vibrator from reaching its rated speed, and cause the motor to continue to draw high starting current for a prolonged period until it burns up. The electric power circuit must be able to handle the high starting current without dropping below 80% of the rated voltage. The most common problems are using a long extension cord with the wire gauge undersized or an undersized transformer which cannot handle the high amp draw on start up. ) Improper Mounting: When an electric motor runs slower than its rated speed, it will draw excessive current and eventually burn up. A non-rigid mount hinders the vibrator from reaching full running speed. In screen and feeder applications, the vibrator may get trapped in the resonant frequency of the structure and not have enough power to reach full running speed. Adjust the springs if possible to change resonant frequency. Improper mounting of the electric vibrator will cause it to fail. VII. WEIGHT SETTING ADJUSTMENTS The centrifugal force of the vibrator may be controlled by adjusting the eccentric weights. The speed of the vibrator is not affected by the adjustment of the eccentric weights. See Performance Data on page 0 for force produced at each setting. There are single and double ended shafts. It is very important to adjust eccentric weights on both ends of the double ended shaft identically. QT-80- The QT-80- has only one adjustable weight. Each weight has settings marked 40,60, and 80 force pounds. The factory setting is 60 force pounds. Cover Socket Set Screw QT-80- Figure 6. Loosen and remove the bolts from the housing cover.. Remove the cover. This may require tapping the empty bolt holes with an object causing the cover to rotate, and the holes to misalign. Tap cover out with an object through empty bolt hole on motor side.. Loosen the set screw securing the weight to the motor shaft. 4. Slide the weight off of the shaft and install the set screw into the desired hole. 5. Replace the weight on the motor shaft and tighten the set screw securely. The set screw must engage the flat on the motor shaft. 6. Check to verify that the weight rotates freely within the housing - adjust if necessary. 7. Reinstall the cover using Loctite 55 Gasket Eliminator. Tighten screws securely. 8. Run the unit to verify proper operation. 4

15 QT-60- The QT-I60 has adjustable weights. Each weight has a setting marked 40, 60, and 80 force pounds. The factory setting is 60 on each weight for a total of 0 force pounds. Set s at the same setting on each end of the shaft for proper operation. QT-60- Figure 7 Cover. Loosen and remove the four draw bolts holding the assembly together.. Remove the weight cover.. Loosen the set screw and slide the weight from the motor shaft. 4. Install the set screw into the desired hole. 5. Replace the weight back onto the motor shaft. 6. Tighten the set screw securely. Be certain the set screw engages the flat machined surface on the motor shaft. 7. Reinstall the cover using Loctite 55 Gasket Eliminator. Torque the draw bolts to 9 ft-lb (. N-m). 8. Run the vibrator to verify proper operation. Cover Sss Draw Bolt Bearing Cover Stator Draw Bolt Sss Housing Socket Set Screw Lock Nut & Flat Washer. Using locking pliers, anchor the draw bolts at any point between the housing ends, while the nuts are removed from one end of the draw bolts.. Remove the draw bolts and weight covers from the housings, exposing the weights. To remove the cover, this may require tapping the empty bolt holes with an object causing the cover to rotate, and the holes to misalign.tap the cover out with an object through the empty bolt hole on motor side.. Loosen the set screw from each weight and slide the weight from the motor shaft. 4. Replace the set screws into the desired hole and replace the weight on the motor shaft. The set screw must engage the flat on the motor shaft. Tighten set screws securely. 5. Verify that the weights rotate freely within the housing. 6. Reinstall the covers using Loctite 55 Gasket Eliminator. Torque the draw bolts to ft-lb (4 N-m). 7. Run the unit to verify proper operation. QT-50 and QT & Phase These two models have one adjustable weight with two settings. The QT-50 has settings marked 75 and 50 force pounds (factory setting is 75). The QT-500 has settings marked 00 and 500 force pounds (factory setting is 00). Cover How To Remove Cover QT-50, QT-500 and QT-000 QT-50 QT-500 Figure 8. Remove draw bolts.. Pry off covers with a screwdriver using the milled-in access slot as shown below.. Upon re-assembly, install draw bolts and torque to 9 ft-lb (. N-m). Removing Bolts Figure 9 5

16 QT & Phase The QT-000 has two adjustable weights. Each weight has a setting marked 50 and 500 force pounds. The factory setting on each weight is 50 for a total of 700 force pounds. Adjust weight to the 500 force pound setting for 000 pounds of force output. Cover SSS Draw Bolt Housing Stator Housing Cover QT-000 Figure 0. Using locking pliers, anchor the draw bolts at any point between the housing ends, while the nuts are removed from one end of the draw bolts.. Remove the draw bolts and weight covers from the housings, exposing the weights. To remove the cover, it may require tapping the empty bolt holes with an object causing the cover to rotate, and the holes to misalign. Tap cover out with an object through empty bolt hole on motor side.. Loosen the set screw from each weight and slide the weight from the motor shaft. 4. Replace the set screws into the desired hole and replace the weight on the motor shaft The set screw must engage the flat milled into the motor shaft. Tighten set screws securely 5. Verify that the weights rotate freely within the housing. 6. Reinstall the covers using Loctite 55 Gasket Eliminator. Torque the draw bolts to 9 ft-lb (. N-m). 7. Run the unit to verify proper operation. DEG Models - & Phase DEG models 6, 45, 90, 0, 00, 50, and 50 have two adjustable weights with three settings (positions). Position - produces the maximum force Position - produces the medium force Position - produces the minimum force Unless otherwise requested, Global will preset the eccentric weights at position, the middle or medium setting. DEG models 5 and 5000 have two adjustable weights with ten settings. When the two weights, the fixed and adjustable, are aligned with each other the force output is at 00%. The vibrator will produce the most force output at that configuration. At position 90, the force output is 90% of the maximum force. At position 80, the force output is 80% of the maximum force and so on. Unless otherwise requested, Global will preset these vibrators at position 50 for 50% of maximum force output the vibrator is capable of producing.. Remove the cover from each end of the vibrator.. Remove the bolt or set screw that fastens the adjustable outer weights. Pull the outer weights off the rotor/shaft. Brace the weights with a wooden pry bar for bolt removal. Do not allow the pry bar to enter the motor housing where it may damage the wiring.. Use Loctite 6 or equivalent adhesive on all fasteners when reassembling vibrators. 4. Reposition the adjustable weights to the desired setting and reinstall the bolt or set screw that fastens the weight. See chart on page 0 for eccentric weight settings. 5. Securely tighten the eccentric weight fasteners. Torque all DEG model draw bolts to ft-lb (6. N-M). 6. Reinstall the covers using Loctite 55 Gasket Eliminator. 6

17 Global Manufacturing, Inc TOLL FREE USA & CANADA DEG-6- or ph DEG-45- or ph DEG-90- or ph DEG-0- DEG-00- DEG-50- DEG-50- Screws Screws /4-0 SCS Adjustable Keyways, & Screws /4-0 Hex Bolt Fixed Bolt Holes,, Screws / - Hex Bolt Flat Washer Key Adjustable Figure Figure DEG DEG-5- Fixed Cover Bolt Adjustable Screws Key Fixed Adjustable Figure 7

18 VIII. DIMENSIONS Vibrator Model DIMENSIONS FOR QT & DEG QUIET THUNDER VIBRATORS DWG QT-80 QT-60 QT-50 QT-500 QT DEG-6 5 DEG-45 5 DEG-90 5 DEG-0 5 DEG-00 DEG-50 5 DEG-50 5 DEG DEG-5 5 A B C D E F G H Total Length Foot Width Total Height Total Width Bolt Hole Center Length Bolt Hole Center Width Foot Thickness Bolt Hole Size lbs in in in in in in in in kg mm mm mm mm mm mm mm mm X 0.68 N/A X X X 64 X N/A X N/A X Drawing A H C B F G D 8

19 Drawing E H F C A B G D Drawing B A GLOBAL MANUFACTURING, INC. C H G F D Drawing 4 A E H C F G D B Drawing 5 A E F C B H G D 9

20 IX. PERFORMANCE DATA Vibrator Model Vibrator Performance Data Unbalance Centrifugal Force Pounds Maximum Material in Minimum Medium Maximum Speed Minimum Medium Maximum Slope lb-in lb-in lb-in RPM Force Pounds Force Pounds Force Pounds Pounds Single Phase Three Phase kg-mm kg-mm kg-mm Kilonewton Kilonewton Kilonewton Kilograms QT-80- QT-60- QT-50- QT-500- QT-000- DEG-6- DEG-45- DEG-90- QT-50- QT-500- QT-000- DEG-6- DEG-45- DEG-90- DEG-0- DEG-50- DEG-50- DEG , n/a n/a 50, n/a n/a.,5.0 n/a.5 50 n/a 500 5, n/a 7.56 n/a.,70.0 n/a n/a 000 0, n/a 46. n/a , , , , , , , , , , , , , ,77 50 Hertz Model DEG-5- DEG , , , ,00 0

21 X. Proper Voltage and Amperage Readings must be done before operating vibrator.! IMPORTANT Typically, motors can tolerate a 0% drop in voltage while running. Since start-up lasts only to seconds, a 0% drop should be tolerated for that short period of time when the motor is pulling higher amps. The best way to check this is to use a voltage meter at the motor. Check minimum voltage during start-up and the running voltage once the motor has reached its running speed. Assuming 0 volt motor, it needs at least 96 volts during start-up, and once the motor reaches its operational speed it needs 08 volts. When sizing an extension cord one must be careful because the extension cord is only one source of voltage drop. The power source might also fluctuate. It is best to assume the power source could fluctuate by 5%. Thus the 0 volt source might at times only provide 4 volts. Therefore, the extension cord cannot cause more than a 5% voltage drop during start-up and only a 5% drop after reaching operational speed. With a 00 4AWG copper wire extension cord, one would get a 0. voltage (6.86%) drop during motor start-up when pulling 9 amps. This means the voltage at the vibrator might be as low as 9.77 volts, too low for proper starting. Once the vibrator reaches full speed it pulls only.6 amps. The voltage drop here would be.49 volts leaving.65 volts, which should be sufficient to keep the unit running. HOWEVER, the low voltage during start-up causes excess heat that degrades the motor insulation. This effect is cumulative, so even though the vibrator starts the first, second, or third time the damage done by low voltage is building. Eventually the insulation fails and the motor will burn up. In this example only the start windings will fail prematurely, which will leave the vibrator inoperable. To further explain voltage drops pertaining to the above example: If a AWG cord is used the voltage drops will be: Start-up=.7 volts giving a net of 0. volts Run=0.849 volts giving a net of. volts This extension cord would be adequate. If a 0AWG cord is used the voltage drops will be: Start-up=8 volts giving a net of 06 volts Run=0.54 volts giving a net of.5 volts This extension cord would be better. There is a good website with a nice voltage drop calculator. If you have the wire size, length, power source voltage, and amp draw it will calculate the voltage drop. YOU MUST ALSO CHECK THE AMP DRAW. It the amp draw exceeds the manufacturer s specifications then the vibrator is probably not properly mounted. The mount may not be level or lack proper rigidity. Please follow the mounting instructions in this manual.

22 XI. TROUBLESHOOTING Problem Probable Cause Solution Single phasing phase vibrators only Circuit breaker is tripped or fuse is blown. Switch or starter contact is not closing properly. Correct the problem that caused the overload to occur. See page 9 and 4. Reset breaker or replace fuse. Replace or repair starter. Conductor or wiring to vibrator is defective. Repair or replace conductor. supply malfunctions, such as the loss of one phase of a distribution transformer caused by lightning, wind, ice storms, etc. Replace damaged wiring. Replace transformer. You may have to contact local electric utility to repair their circuits. Excessive noise Vibrator mount is not rigid. Make sure mount is rigid and the vibrator is perpendicular to channel iron See pages 6-8. Tighten all bolts. Check for cracked welds or broken housing. Vibrator will not start Single phase circuit breaker (purchased separately) is tripped. Circuit is interrupted. Correct the problem that caused the overload. Reset breaker. See page 9 and 4. Make sure all leads are hot. Single phase vibrator has a damaged electronic starting switch. Replace electronic starting switch. Vibrator runs hot or overheats (Check voltage and amp draw on start-up and on run.) Excessive current (Check voltage and amp draw on start-up and on run.) Vibrator mount is not rigid Make sure mount is rigid. See pages 6-8. Tighten all bolts. Check for cracked welds or a broken housing. Single phase vibrator has damaged electronic starting switch. Voltage is low. Conductor gauge or extension cord is inadequate or too small. Stop-Start time intervals too short. The motor is restarted quickly again after stopping. Ambient temperature is too hot for vibrator. Mounting surface is not flat and motor is binding. Vibrator mount is not rigid and/or vibrator is operated on an empty bin. Single phase units - conductor wires may be inadequate, keeping start switch from disengaging starter coils. Replace electronic starting switch. Use a heavier gauge when using extension cords or conductor. See page for voltage/amp information and how to size an extension cord. The time between start-ups needs to be at least two minutes. The amperage draw at start-up is high and creates heat. A two minute time delay allows motor to cool down. Protect vibrator from ambient temperature above 04 F (40 C). Check mount plate surface. Must be flat. Use shims to level the vibrator mount if necessary. Make sure mount is rigid and the vibrator is perpendicular to channel iron. Tighten all bolts. Do not operate vibrator on an empty bin. See pages 6-8. See Voltage and Amperage information on page. Mounting surface is not flat and motor is binding. Check mount plate surface. Must be flat. Use shims to level the vibrator mount if necessary.

Models: DC Electric Vibrators. Operating Instructions CEG CEG CEG CEG CEG CEG

Models: DC Electric Vibrators. Operating Instructions CEG CEG CEG CEG CEG CEG DC Electric Vibrators Operating Instructions Global External bin & hopper 12 & 24 Volt DC Electric Vibrators Models: CEG-400-12 CEG-800-12 CEG-1200-12 CEG-400-24 CEG-800-24 CEG-1200-24 Global Manufacturing

More information

Models: DC Electric Vibrators. Operating Instructions CEG CEG CEG CEG CEG

Models: DC Electric Vibrators. Operating Instructions CEG CEG CEG CEG CEG DC Electric Vibrators Operating Instructions Global External 12-Volt DC Electric Vibrators Intermittent Use Only Models: CEG-1800-12 CEG-2200-12 CEG-2800-12 CEG-3600-12 CEG-4200-12 INDUSTRIAL ELECTRIC

More information

Models RE & RES. Rotary Electric Vibrators. Installation, Operating and Maintenance Instructions

Models RE & RES. Rotary Electric Vibrators. Installation, Operating and Maintenance Instructions Models RE & RES Rotary Electric Vibrators Installation, Operating and Maintenance Instructions IMPORTANT: The dependable performance and safe operation of the RE and RES rotary electric vibrator requires

More information

Cougar B Series Electric Vibrators 3 Frame

Cougar B Series Electric Vibrators 3 Frame Cougar B Series Electric Vibrators 3 Frame Go to Cougar B Series Electric Vibrators web page Operator s Manual M3929 Important MARTIN ENGINEERING HEREBY DISCLAIMS ANY LIABILITY FOR: DAMAGE DUE TO CONTAMINATION

More information

Hydraulic Motors Repair Instructions

Hydraulic Motors Repair Instructions Hydraulic Motors Repair Instructions Motors for Global External Hydraulic Vibrators Models 2HC - pn #251020 5HC - pn #251050 Global Manufacturing, Inc. 101 E 22nd St Little Rock, Arkansas 2206 V I B R

More information

MODEL SCA Installation and Operation Manual Important:

MODEL SCA Installation and Operation Manual Important: MODEL SCA Installation and Operation Manual Important: This manual contains specific cautionary statements relative to worker safety. Read this manual thoroughly and follow as directed. It is impossible

More information

Mizer Single Pump and Starter Box

Mizer Single Pump and Starter Box Mizer Single Pump and Starter Box Table of Contents Line Diagram... 2 Overview... 3 Booster Pump Specifications... 3 Water... 3 Electrical... 3 Models... 3 Mounting... 4 Electrical... 6 Motor Rotation...

More information

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS

ALL700/ALL700-CM INSTALLATION INSTRUCTIONS ALL700/ALL700-CM INSTALLATION INSTRUCTIONS Aladdin Light Lift, Inc. (256) 429-9700 61 Shields Road (877) 287-4601 Huntsville, AL 35811 www.aladdinlightlift.com Patent #5105349 WARNING: Disconnect power

More information

ALL W INSTALLATION INSTRUCTIONS

ALL W INSTALLATION INSTRUCTIONS ALL1000-3300W INSTALLATION INSTRUCTIONS Aladdin Light Lift, Inc. (256) 429-9700 61 Shields Road (877) 287-4601 Huntsville, AL 35811 www.aladdinlightlift.com Patent #5105349 WARNING: Disconnect power source

More information

INSTALLATION MANUAL. Thunderstone Manufacturing LLC 3400 West O Street Lincoln, NE (Fax)

INSTALLATION MANUAL. Thunderstone Manufacturing LLC 3400 West O Street Lincoln, NE (Fax) INSTALLATION MANUAL August 7 th 2018 43 /48 /50 2011 and Older Timpte STD/Split 36 Style Hopper Trailers with Roller Bearing Doors Kit #101533 for 96w & Kit #101534 for 102w Thunderstone Manufacturing

More information

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Model 54011-0 OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475

More information

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference.

AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference. AIR CLEANERS Model MC 3000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference. MODEL MC 3000 SPECIFICATION Input Volts: 208-230/430 VAC, 60Hz, 3 Phase

More information

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP Model 51101-0 OWNER S MANUAL SUBMERSIBLE UTILITY PUMP Questions, problems, missing parts? Before returning to the store call AQUAPRO Customer Service 8 a.m. - 5 p.m., EST, Monday-Friday 1-844-242-2475

More information

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS

INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS 471 US Hwy 250 East, Ashland, Ohio 44805 PH: 419-207-9400 FX: 419-207-8031 INSTALLATION AND SERVICE INSTRUCTIONS AND REPAIR PARTS LIST FOR MODELS K4RP & K4VP SUBMERSIBLE SOLIDS-HANDLING SEWAGE PUMPS 10/2014

More information

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM Performance Model HP GPH of Water @ Total Feet Of Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. 25 ft. Max. Lift SUNC1200

More information

Cougar B Series Electric Vibrators 4 Frame

Cougar B Series Electric Vibrators 4 Frame Cougar B Series Electric Vibrators 4 Frame Go to Cougar B Series Electric Vibrators web page Operator s Manual M3930 Important MARTIN ENGINEERING HEREBY DISCLAIMS ANY LIABILITY FOR: DAMAGE DUE TO CONTAMINATION

More information

INSTALLATION & OPERATION MANUAL

INSTALLATION & OPERATION MANUAL INSTALLATION & OPERATION MANUAL PRE-ASSEMBLED PRIMARY & BATTERY BACK-UP SUMP PUMP SYSTEM 5030CVSPBUSS, 5033CVSPBUSS www.aymcdonald.com A.Y. McDonald BBU Manual Revised 8-13 3210-479 Rev. A 12 This pump

More information

Cougar D and U Series Electric Vibrators

Cougar D and U Series Electric Vibrators Cougar D and U Series Electric Vibrators Go to Cougar D and U Series Electric Vibrators web page Operator s Manual M3933 Important MARTIN ENGINEERING HEREBY DISCLAIMS ANY LIABILITY FOR: DAMAGE DUE TO CONTAMINATION

More information

COOKSON OWNER'S MANUAL

COOKSON OWNER'S MANUAL COOKSON OWNER'S MANUAL FDO-A10 INDUSTRIAL DUTY FIRE DOOR OPERATOR R L I S T E D 3040233 US CONTROL PANEL SERIAL# OPERATOR SERIAL# 9001.DWG ECN 0959 REV 4 SPECIFICATIONS MOTOR TYPE:...INTERMITTENT HORSEPOWER:...1/8

More information

END SUCTION CENTRIFUGAL PUMPS

END SUCTION CENTRIFUGAL PUMPS OWNERS GUIDE TO INSTALLATION AND OPERATION FW000 009 Supersedes 07 END SUCTION CENTRIFUGAL PUMPS READ THESE INSTRUCTIONS CAREFULLY Read these installation instructions in detail before installing your

More information

LESTRONIC II BATTERY CHARGER MODEL 07210

LESTRONIC II BATTERY CHARGER MODEL 07210 LESTRONIC II BATTERY CHARGER MODEL 07210 PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS For correct operation of the equipment, it is important to read and be familiar with this entire manual

More information

MODEL ELC-12/40-CVM-D BATTERY CHARGER

MODEL ELC-12/40-CVM-D BATTERY CHARGER NATIONAL RAILWAY SUPPLY MODEL ELC-12/40-CVM-D BATTERY CHARGER Installing, Operating and Service Instructions for the ELC-12/40-CVM-D Solid State Charger PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING

More information

Installation Manual. For. High Speed Alumavator and Platinum. 10 and 23 Degree. Elevator Boat Lifts

Installation Manual. For. High Speed Alumavator and Platinum. 10 and 23 Degree. Elevator Boat Lifts Installation Manual For High Speed Alumavator and Platinum 10 and 23 Degree Elevator Boat Lifts Page 2 Safety Precautions 1. Your boat lift is a heavy duty piece of equipment. It is important that all

More information

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches An Investment in Plant Floor Safety 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches Notes 2 802C Cable Pull Safety Switches Safety and Application Safety

More information

3 Phase Smart Controller

3 Phase Smart Controller 3 Phase Smart Controller Installation and Owner s Manual STP-SCIII 208-230 VAC, 60Hz, 120 Volt Coil Franklin Fueling 3760 Marsh Rd. Madison WI 53718 USA Tel: +1 608 838 8786 800 225 9787 Fax: +1 608 838

More information

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL LPC 20 LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER Unit supplied with one of these displays MODEL #: 091-207-12 INPUT: 120 Volt, 50/60 Hz, 7 Amps OUTPUT: 20 Amps File:

More information

MODEL ELC-12/60-D BATTERY CHARGER

MODEL ELC-12/60-D BATTERY CHARGER *32198* NATIONAL RAILWAY SUPPLY Installing, Operating and Service Instructions for the 12/60 Solid State Charger MODEL ELC-12/60-D BATTERY CHARGER PLEASE SAVE THESE IMPORTANT SAFETY AND OPERATING INSTRUCTIONS

More information

UNIT VIBRATOR MODELS 60U AND 70U

UNIT VIBRATOR MODELS 60U AND 70U VM-3560B Installation, Operation and Maintenance Instructions UNIT VIBRATOR MODELS 60U AND 70U ERIEZ MAGNETICS HEADQUARTERS: 2200 ASBURY ROAD, ERIE, PA 16506 1440 U.S.A. WORLD AUTHORITY IN ADVANCED TECHNOLOGY

More information

3 FT CORD Models , , , FT CORD W/GFCI Models , , ,

3 FT CORD Models , , , FT CORD W/GFCI Models , , , POWERLINE XP II Swimming Pool Pump (Light Oak color model) With Automatic Timer 3 FT CORD Models 0-1395-226, 0-1396-226, 0-1397-226, 0-1398-226 25 FT CORD W/GFCI Models 0-1395-220, 0-1396-220, 0-1397-220,

More information

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions

Wilo SP Series Submersible Utility Pumps ETT. ETT Installation and operating instructions Wilo SP Series Submersible Utility Pumps ETT ETT24-10.25 Installation and operating instructions 1. PREINSTALLATION CHECK Inspect this pump before it is used. Occasionally, pumps can be damaged during

More information

ALL700RM-230V INSTALLATION INSTRUCTIONS

ALL700RM-230V INSTALLATION INSTRUCTIONS ALL700RM-230V INSTALLATION INSTRUCTIONS Aladdin Light Lift, Inc. (256) 429-9700 61 Shields Road (877) 287-4601 Huntsville, AL 35811 www.aladdinlightlift.com Patent #5105349 WARNING: Disconnect power source

More information

GPS AutoSteer System Installation Manual

GPS AutoSteer System Installation Manual GPS AutoSteer System Installation Manual Supported Vehicles Case IH Vehicles Case 2577 Combines Case 2588 Combines Accuguide Ready PN: 602-0233-01-A LEGAL DISCLAIMER Note: Read and follow ALL instructions

More information

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , ,

3 FT CORD UL/NEC Models , , , FT CORD w/gfci UL Models , , , POWERLINE XP I Swimming Pool Pump (Light Oak color model) 3 FT CORD UL/NEC Models 0-1295-206, 0-1296-206, 0-1297-206, 0-1298-206 25 FT CORD w/gfci UL Models 0-1295-200, 0-1296-200, 0-1297-200, 0-1298-200

More information

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET LESTRONIC II BATTERY CHARGER TAYLOR-DUNN 79-301-10 MODEL 13110-32 TYPE 24LC25-8ET AC Supply: DC Output: Battery Capacity: Specifications 120 volts, 60 Hertz, single-phase 24 volts, 32 amps Use only on

More information

Installation Instructions. QuickSilver Shifter. Fits: GM, Ford, Chrysler Transmissions See Application Guide for Specific Applications Part # 80683

Installation Instructions. QuickSilver Shifter. Fits: GM, Ford, Chrysler Transmissions See Application Guide for Specific Applications Part # 80683 Installation Instructions QuickSilver Shifter Fits: GM, Ford, Chrysler Transmissions See Application Guide for Specific Applications Part # 80683 WORK SAFELY! For maximum safety, perform this installation

More information

PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number and After

PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number and After PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number 28640996 and After Record Platter System Identification Numbers Here: Model # Serial # Table of Contents Program

More information

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax: INSTRUCTION MANUAL AUTO CHARGE 4000 AUTOMATIC DUAL OUTPUT BATTERY CHARGER MODEL #: 091-89-12 INPUT: 120 Volt, 50/60 Hz, 8 Amps OUTPUT BATTERY CHARGER: 40 Amps OUTPUT BATTERY SAVER: 5 Amps File: IM_091-89-12_reve.indd

More information

PUMP PLUS 1000 PLC MODEL #: PP AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

PUMP PLUS 1000 PLC MODEL #: PP AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL PUMP PLUS 1000 PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER Unit supplied with one of these displays MODEL #: 091-215-12-PP INPUT: 120 Volt, 60 Hz, 3.5 Amps OUTPUT BATTERY 1 and 2: 15

More information

Instruction Sheet. 1/2 HP Portable Electric Pumps SAFETY FIRST. L2062 Rev. F 02/ IMPORTANT RECEIVING INSTRUCTIONS 2.

Instruction Sheet. 1/2 HP Portable Electric Pumps SAFETY FIRST. L2062 Rev. F 02/ IMPORTANT RECEIVING INSTRUCTIONS 2. Instruction Sheet 1/2 HP Portable Electric Pumps L2062 Rev. F 02/12 Index: English:...................................... 1-7 Français:.................................... 8-14 Deutsch:...................................

More information

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL INSTRUCTION MANUAL IM245 RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL SAFETY INSTRUCTIONS TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR

More information

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps

Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps Installation, Operation and Maintenance Manual Stancor SSD & SL Series Pumps EI-700-008 Rev -- Table of Contents Safety Guidelines 3 Caution 4 Wiring 4 Maintenance 4 Nameplate format 4 Prior to Operation

More information

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C C Mobile Communications 13 AMPERE POWER SUPPLY 19A704647P1-P3 CAUTION THESE SERVICING INSTRUCTIONS ARE FOR USE BY QUALI- FIED PERSONNEL ONLY. TO AVOID ELECTRIC SHOCK DO NOT PERFORM ANY SERVICING OTHER

More information

ONE TOUCH CONTROL BOX

ONE TOUCH CONTROL BOX ONE TOUCH CONTROL BOX CONVERSION KIT INSTRUCTIONS REMOVAL, INSTALLATION, OPERATION, AND REMOTE CONTROL PROGRAMMING THUNDERSTONE PART #101322 REVISION A JULY 14 TH 2016 2 P a g e INSTALLING THE THUNDER

More information

Model H/HB Heavy-Duty Industrial Drawbar Door Operator Safety, Installation and Service Manual

Model H/HB Heavy-Duty Industrial Drawbar Door Operator Safety, Installation and Service Manual Model H/HB Heavy-Duty Industrial Drawbar Door Operator Safety, Installation and Service Manual OSCO requires use of an electric edge or photoelectric control for pedestrian protection on all automatic

More information

Service Instructions. Syntron Pneumatic Turbine Vibrators Model: TAM TB TBM

Service Instructions. Syntron Pneumatic Turbine Vibrators Model: TAM TB TBM Service Instructions Syntron Pneumatic Turbine Vibrators Model: TAM TB TBM Syntron Pneumatic Turbine Vibrators Models TAM, TB, and TBM Installation Operation Maintenance 1 Table of Contents General Section

More information

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater. 0 EDITION AIM MANUAL SUBMERSIBLE MORS APPLICATION INSTALLATION 60 Hz, Single-Phase and Three-Phase Motors franklinwater.com All Motors System Troubleshooting Motor Does Not Start A. No power or incorrect

More information

Operating Instructions. Internal Concrete Vibrators. VMP with Cage

Operating Instructions. Internal Concrete Vibrators. VMP with Cage Viber Power Unit Operating Instructions Pneumatic Power Unit for Viber Internal Concrete Vibrators MODEL: VMP TURBO VMP with Cage VMP with Handle Global Manufacturing Inc. 1801 East 22nd St Little Rock,

More information

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL PUMP PLUS 2000 PLC AUTOMATIC DUAL OUTPUT BATTERY CHARGER Supplied with Dual Bar Graph Display MODEL #: 091-237-12-PP INPUT: 120 Volt, 60 Hz, 3.5 Amps OUTPUT BATTERY 1 and 2: 15 or 18

More information

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS

Model and Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS. PumpAgents.com - buy pumps and parts online INDUSTRIAL DIAPHRAGM PUMPS Model 31801 and 31800 Series 115 VAC INDUSTRIAL DIAPHRAGM PUMPS INDUSTRIAL DIAPHRAGM PUMPS FEATURES Run Dry Ability Self-Priming Thermal Overload Protected Motor Easy Installation Low Amp Draw Compact

More information

Installation & Operating Manual

Installation & Operating Manual Installation & Operating Manual VN Series Non-Clog Pumps Congratulations On Your Choice In Purchasing This Webtrol Pump 10/15 Edition Its Quality is unsurpassed in material and workmanship and has been

More information

GENESIS Electronic Brake Controller Hayes Brake Controller Company - P/N 81790

GENESIS Electronic Brake Controller Hayes Brake Controller Company - P/N 81790 GENESIS Electronic Brake Controller Hayes Brake Controller Company - P/N 81790 INSTALLATION MANUAL For trailers with 2-8 electric brakes and vehicles with 12 volt negative ground systems only. READ AND

More information

High Frequency SineWave Guardian TM

High Frequency SineWave Guardian TM High Frequency SineWave Guardian TM 380V 480V INSTALLATION GUIDE FORM: SHF-IG-E REL. January 2018 REV. 002 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation

More information

Instruction Bulletin. Jockey Pump Controller

Instruction Bulletin. Jockey Pump Controller Instruction Bulletin Jockey Pump Controller Installation Start Up Service This instruction bulletin is a guide for personnel involved with maintenance, engineering and approval of Fire Pump equipment and

More information

Installation Manual. For. Alumavator and Platinum. Vertical Installation. Elevator Boat Lifts

Installation Manual. For. Alumavator and Platinum. Vertical Installation. Elevator Boat Lifts Installation Manual For Alumavator and Platinum Vertical Installation Elevator Boat Lifts Page 2 Safety Precautions 1. Your boat lift is a heavy duty piece of equipment. It is important that all persons

More information

SUNC3000 / Item #40885

SUNC3000 / Item #40885 SUNC3000 / Item #40885 AUTOMATIC POOL COVER PUMP OPERATIONS MANUAL WWW.SUNRUNNERPOOL.COM 1 . Performance GPH of Water @ Total Feet Of Lift MODEL HP Max. Lift 0 ft. 5 ft. 10 ft. 15 ft. 20 ft. SUNC3000 1/3

More information

AIR CLEANERS. Model MX 6000 OWNER S MANUAL CAUTION. Read complete instructions before operating. Please file for future reference.

AIR CLEANERS. Model MX 6000 OWNER S MANUAL CAUTION. Read complete instructions before operating. Please file for future reference. AIR CLEANERS Model MX 6000 OWNER S MANUAL CAUTION Read complete instructions before operating. Please file for future reference. MODEL MX 6000 SPECIFICATIONS Input Volts: 208-230/460 VAC, 60Hz, 3 Phase

More information

END SUCTION CENTRIFUGAL PUMPS

END SUCTION CENTRIFUGAL PUMPS OWNERS GUIDE TO INSTALLATION AND OPERATION END SUCTION CENTRIFUGAL PUMPS FW000 0 Supersedes 009 READ THESE INSTRUCTIONS CAREFULLY Read these installation instructions in detail before installing your pump.

More information

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS 1 AQUALUMIN III NICHELESS POOL LIGHT INSTALLATION GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Section Contents 1. Installing a mounting bracket and light

More information

Motor Trouble-Shooting Chart Caution:. Disconnect power to the motor before performing service or maintenance.. Discharge all capacitors before servicing motor.. Always keep hands and clothing away from

More information

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light installation Manual English Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light FOR YOUR SAFETY - This product must be installed and serviced by a contractor who is licensed and qualified

More information

Operating Instructions

Operating Instructions DuroSite & SafeSite Area Light with Adapters Important Information: These instructions contain safety information, read and follow them carefully. Dialight will not accept any responsibility for injury,

More information

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER SPECIFICATIONS: *Photo for reference only* Part number 8890439 Mode Select: Selects Battery Type Refer to Section 6. IMPORTANT: READ

More information

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information

INSTALLATION INSTRUCTIONS. Solid-State Series !! NOTE!! Covers the following models: Refer to INSERT for additional information INSTALLATION INSTRUCTIONS Solid-State Series!! NOTE!! Covers the following models: " CS6100 - CS7100 " CS6200 - CS9200 " CS6220 - CS9220 " CS6230 - CS9230 " CS6500 - CS7500 " CS6330 - CS9300 " CS9400 -

More information

INSTALLATION & OWNER S MANUAL

INSTALLATION & OWNER S MANUAL 1 of 18 INSTALLATION & OWNER S MANUAL (*Not including cab & other accessories) A/C Alternator Kit: Yamaha Drive & Drive2 P/N: 1ACYDR2DRK Recommended it be installed with Curtis Cab: Sandstone (p/n 1GCYD1-A,

More information

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate. FEATURES Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate. Silicon diodes with inherent surge protection operated at a conservative percentage

More information

Specifications Mounting Instructions Operating Instructions Parts List Dimensions Maintenance Technical Data

Specifications Mounting Instructions Operating Instructions Parts List Dimensions Maintenance Technical Data Model DC 12 & 24 Volt Battery Operated Specifications Mounting Instructions Operating Instructions Parts List Dimensions Maintenance Technical Data SILENT ^ Corporate HQ & Factory: 75 Stilson Road Wyoming,

More information

XR Conveyor Maintenance Guide

XR Conveyor Maintenance Guide XR Conveyor Maintenance Guide EN-0035 Rev. A XR Conveyor Maintenance Guide www.qdraw.com Table of Contents 05/20/2009 Overview Page 3 XR Conveyor Assembly Page 4 General Information Exploded View of an

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 458295 Automatic Fire Damper Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

HD 7700 Setup & Operator Manual

HD 7700 Setup & Operator Manual HD 7700 Setup & Operator Manual Issue 1 December, 01 Performance Design Inc. The Heavy Duty Ultima (HD 7700) electric punch has been designed to punch most any job that may pass through your bindery or

More information

SERVICE MANUAL (INTERNATIONAL)

SERVICE MANUAL (INTERNATIONAL) SERVICE MANUAL (INTERNATIONAL) IMPINGER CONVEYOR OVENS MODEL 1421-000-E, 1454, 1455 WITH PUSH BUTTON CONTROLS Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States

More information

AUTO CHARGE D PUMP PLUS

AUTO CHARGE D PUMP PLUS INSTRUCTION MANUAL AUTO CHARGE D PUMP PLUS AUTOMATIC DUAL OUTPUT BATTERY CHARGER Designed Specifically for Vehicles with DDEC ENGINES MODEL #: 091-9-DPP INPUT: 120 Volt, 60 Hz, 8 Amps OUTPUT VEHICLE BATTERY:

More information

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING dv Sentry TM 208V 600V INSTALLATION GUIDE FORM: DVS-IG-E REL. January 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Universal Air Series!! NOTE!! Covers the following model: 6000 Series 85-0100B-AZ Rev 0 5/07 To ensure that the system is installed properly, provide your electrician with these

More information

Read carefully and follow all safety rules and operating instructions before first use of this product.

Read carefully and follow all safety rules and operating instructions before first use of this product. operating manual & parts list 82061, 82062, 82071, 82081 & 82101 6, 7, 8 & 10 BENCH GRINDER Read carefully and follow all safety rules and operating instructions before first use of this product. 7.39-020

More information

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V SOLAR LIGHTING CONTROLLER OPERATOR S MANUAL SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V 10A / 12V 10A / 24V 20A / 12V 20A / 24V 1098 Washington Crossing Road Washington Crossing,

More information

Instruction Book for. ContouR ElECtRol

Instruction Book for. ContouR ElECtRol Instruction Book for ContouR ElECtRol IMPORTANT SAFETY INSTRUCTIONS When using your video equipment, basic safety precautions should always be followed, including the following: 1. Read and understand

More information

COOKSON OWNER S MANUAL

COOKSON OWNER S MANUAL COOKSON OWNER S MANUAL ELECTRIC CLUTCH RELEASE FOR TUBULAR MOTOR 3117(1) ECN 0951 BY RG 10/28/10 1 PATENT NO. 6,155,324 SPECIFICATIONS ELECTRICAL SPECIFICATIONS TUBULAR MOTOR FOR TUBULAR MOTOR ELECTRICAL

More information

Lifting height 5.5" - 72" with adapters " Height overall 165" Width between columns 122" Drive through 109" Width overall 151.

Lifting height 5.5 - 72 with adapters  Height overall 165 Width between columns 122 Drive through 109 Width overall 151. Model Number TP12KC-D Capacity 12,000 lbs. Lifting height 5.5" - 72" with adapters 79.625" Height overall 165" Width between columns 122" Drive through 109" Width overall 151.125" Arm extension 37.5" -

More information

HEAVY DUTY ONBOARD AIR SYSTEM PART NO

HEAVY DUTY ONBOARD AIR SYSTEM PART NO IMPORTANT: It is essential that you and any other operator of this product read and understand the contents of this manual before installing and using this product. SAVE THIS MANUAL FOR FUTURE REFERENCE

More information

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL AUTO CHARGE D2 AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER Designed Specifically for Vehicles with DDEC ENGINES MODEL #: 091-74-12 INPUT: 120 Volt, 60 Hz, 8 Amps OUTPUT VEHICLE BATTERY 1

More information

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL INSTRUCTION MANUAL AUTO CHARGE 4000 LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER Unit supplied with this display MODEL #: 091-89-12 INPUT: 120 Volt, 50/60 Hz, 5 Amps OUTPUT: 45 Amps File:

More information

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING Matrix AP 400V 690V INSTALLATION GUIDE FORM: MAP-IG-E REL. May 2017 REV. 002 2017 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

Safe-T-element Installation Instructions

Safe-T-element Installation Instructions Safe-T-element Installation Instructions For: PTI STEZA (2x2 Burner Configuration) & PTI STEZB (3x1 Burner Configuration) Revision K (May. 3 2012) TABLE OF CONTENTS 1. PREPARATION... 3 1.1 General Safety

More information

Syntron Pneumatic Vibrators

Syntron Pneumatic Vibrators Pneumatic Vibrators Syntron Pneumatic Vibrators Syntron Material Handling offers two types of Syntron Pneumatic Vibrators turbine and piston. Turbine models feature rotary action designed to keep noise

More information

Auger Belt Tension Adjustment DB7659

Auger Belt Tension Adjustment DB7659 Rev 1.0 3-23-13 Auger Belt Tension Adjustment DB7659 WARNING Entanglement Hazard - Before performing any adjustment procedures, make sure the engine is off and remove the spark plug wire from the spark

More information

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22 V3 TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22 PREFACE This guide contains instructions for troubleshooting the Steffes Corporation room heating units: Models HPB 11, HPB

More information

Electric Motor Controls BOMA Pre-Quiz

Electric Motor Controls BOMA Pre-Quiz Electric Motor Controls BOMA Pre-Quiz Name: 1. How does a U.P.S. (uninterruptable power supply) work? A. AC rectified to DC batteries then inverted to AC B. Batteries generate DC power C. Generator, batteries,

More information

ESE Series Cast Iron Sewage Pumps

ESE Series Cast Iron Sewage Pumps Owner s Manual ESE Series Cast Iron Sewage Pumps TABLE OF CONTENTS General Safety.................... 2 Specifications..................... 3 Installation.................... 4 & 5 Troubleshooting...................

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Thank you for purchasing ROLTECTM Electric Hopper Conversion. Agri-Cover, Inc. proudly manufactured this hardware using superior quality materials and workmanship. With proper

More information

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

SERVICE MANUAL (DOMESTIC & INTERNATIONAL) SERVICE MANUAL (DOMESTIC & INTERNATIONAL) DUAL TECHNOLOGY FINISHER MODEL 1960 & 1980 SERIES Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States of America Telephone:

More information

Owner s Manual Drill and Light Weight Portable Utility Pumps

Owner s Manual Drill and Light Weight Portable Utility Pumps Owner s Manual Drill and Light Weight Portable Utility Pumps PUP61 Light Weight Utility Pump PUP62 Drill Pump with Kit PUP63 Drill Pump PUP61DC Light Weight Utility Pump LIMITED WARRANTY This pump is warranted

More information

RigMaster Power Service and Repair Manual Document # S901009

RigMaster Power Service and Repair Manual Document # S901009 Document # S901009 WARNING The following procedures present hazards which can result in injury or death. Only persons qualified to carry out electrical and mechanical servicing should undertake this work.

More information

Installation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752

Installation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752 Rocking Piston Compressors Installation and Service Manual for SRC25, SRC252, SRC50, SRC502, SRC75, SRC752 Thank you for purchasing the Stratus SRC series rocking piston compressor. This instruction manual

More information

Matala. VersiFlow Series. Instruction and Maintenance Manual

Matala. VersiFlow Series. Instruction and Maintenance Manual VersiFlow Series High Flow Multi-Purpose "Versatile " Pump V-3200 1/5HP 150W / Discharge 2 V-3900 1/3HP 250W / Discharge 2 V-4700 1/2HP 400W / Discharge 2 V-5600 1HP 750W / Discharge 2 Instruction and

More information

Operating Instructions - Electric Pow'r-Riser Models

Operating Instructions - Electric Pow'r-Riser Models ADivisionOf Templeton, Kenly& Co., Inc. Operating Instructions - Electric Pow'r-Riser Models Table of Contents 1.0 Recieving Instructions 2.0 Safety 3.0 Specifications 4.0 Initial Installation Before Operating

More information

OPERATING INSTRUCTIONS. Note: 6V Charging. Requires Manual Shut Off.

OPERATING INSTRUCTIONS. Note: 6V Charging. Requires Manual Shut Off. Requires Manual Shut Off. 6 / 2 AMP,, DUAL RATE BATTER TTERY CHARGER 45005 OPERATING INSTRUCTIONS E224783 E224783 Note: 6V Charging Due to continuing improvements, actual product may differ slightly from

More information

Maintenance Information

Maintenance Information Form 16575334 Edition 1 April 2005 Electric Screwdrivers EL, EP and ET 34V DC Series Maintenance Information Save These Instructions WARNING Maintenance procedures have the potential for severe shock hazard

More information

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

4 ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause 4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL BEFORE INSTALLING PUMP, BE SURE TO READ THIS OWNER S MANUAL CAREFULLY. CAUTION Fill pump with water before starting or pump will be damaged. The motor on

More information

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE MODEL 600A 6 VOLT BATTERY CHARGER ASSOCIATE IMPORTANT SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS. This manual contains important safety and operating instructions for the battery charger you have purchased.

More information

INSTALLATION AND SERVICE MANUAL FOR TURBO-CARB HIGH CAPACITY CARBONATOR

INSTALLATION AND SERVICE MANUAL FOR TURBO-CARB HIGH CAPACITY CARBONATOR Please refer to the Lancer web site (www.lancercorp.com) for information relating to Lancer Installation and Service Manuals, Instruction Sheets, Technical Bulletins, Service Bulletins, etc. INSTALLATION

More information