Part Number Revision NC, September High Temperature Velocity and Acceleration Sensor Operation and Maintenance Manual

Size: px
Start display at page:

Download "Part Number Revision NC, September High Temperature Velocity and Acceleration Sensor Operation and Maintenance Manual"

Transcription

1 Part Number Revision NC, September High Temperature Velocity and Acceleration Sensor Operation and Maintenance Manual

2 High Temperature Velocity and Acceleration Sensor Operation and Maintenance Manual Copyright 2004 General Electric Company All Rights Reserved. The information contained in this document is subject to change without notice. The following ways of contacting Bently Nevada are provided for those times when you cannot contact your local Bently Nevada representative: Mailing Address 1631 Bently Parkway South Minden, NV USA Telephone Fax Internet About this manual This manual shows how to install the High Temperature Velocity and Acceleration Sensor, how to verify that it is operating correctly, and how to troubleshoot problems. The following publication contains additional information about this sensor: Title Part Number Description High Temperature Velocity and Acceleration Sensor Datasheet List of specifications and ordering information for the sensor ii

3 Installation Installation This section shows how to mount the transducer and electronics and gives guidelines for connecting and routing the integral cable and the interconnect cable. Receiving Inspection The High Temperature Velocity and Acceleration Sensor (HTVAS) consists of a sensing element, an integral cable, electronics and electronics mounting nut (1-12 UNF). Mounting hardware such as transducer bolts, cushion loop clamps and interconnect cables must be purchased separately. Inspect the components of the order as soon as you receive them to see if any damage occurred during shipping. Keep all shipping forms and invoices. If any shipping damage is apparent, file a claim with the carrier and submit a copy to Bently Nevada. Include all model numbers and serial numbers with the claim. We will either repair or replace damaged parts according to the terms and conditions of the sale. Installing the sensor Application Advisory If housing measurements are being made for overall protection of the machine, thought should be given to the usefulness of the measurement for each application. Most common machine malfunctions (imbalance, misalignment, etc.) originate at the rotor and cause an increase (or at least a change) in rotor vibration. In order for any housing measurement alone to be effective for overall machine protection, a significant amount of rotor vibration must be faithfully transmitted to the bearing housing or machine casing, or more specifically, to the mounting location of the transducer. In addition, care should be exercised in the physical installation of the transducer. Improper installation can result in a degradation of the transducer's performance, and/or the generation of signals which do not represent actual machine vibration. Upon request, Bently Nevada can provide engineering services to determine the appropriateness of housing measurements for the machine in question and/or to provide installation assistance. 1

4 High Temperature Velocity and Acceleration Sensor Operation and Maintenance Manual CAUTION The sensor is designed for high temperature applications. Contact with a hot machine or sensor will cause burns. Allow the machine and sensor to cool before installing or servicing the sensor. Step 1- Locate an area to mount the sensor. Verify that the ambient and surface temperatures do not exceed the range listed in Table 1. Table 1: Operating Temperature Range Component Operating Temperature Range C F Sensor Head -54 to to 900 Integral Cable -54 to to 900 Electronics -54 to to 257 Step 2- Prepare or verify that the mounting surface meets the requirements of Figure 1 and Figure 2. 2 Figure 1: Surface Preparation (dimensions are mm [in])

5 Installation Figure 2: Outline Drawing (dimensions are mm [in]) Note: For steps 3 through step 5, refer to Figure 3. Step 3- Mount the sensing element Use four ¼-28 UNF bolts (or equivalent) Torque bolts evenly to 5.65 N-m [50 in-lbs] minimum (higher torque values are possible depending on the bolt grade) Install safety wire fasteners in high temperature or high vibration environments Step 4- Route and install the integral cable. Verify that the ambient and surface temperatures do not exceed the range listed in Table 1. Avoid twisting, kinking or straining the cable Avoid routing the cable near power lines Avoid areas where abrasion will occur Avoid cable bends less than 51 mm [2 in.] radius Secure integral cable at 0.15 m [6 in.] from sensing head using cushion loop clamp Secure integral cable at 0.5 m [18 in.] intervals along remaining integral cable length using cushion loop clamp Step 5- Locate an area to mount the electronics. Verify that the ambient and surface temperatures do not exceed the range listed in Table 1. Fabricate panel 2.3 mm [0.09 in.] to 6.4 mm [0.25 in.] thick with cutout per Figure 3 Avoid twisting the cable more than 45 when inserting the electronics Avoid vibration locations greater than 15g rms Avoid cable bends less than 51 mm [2 in.] radius 3

6 High Temperature Velocity and Acceleration Sensor Operation and Maintenance Manual Secure integral cable at 0.15 m [6 in.] from the electronics using cushion loop clamp Torque electronics mounting nut to N-m [37-52 ft-lbs] Install a safety wire on the mounting nut Figure 3: Sensor, cable and electronics installation (dimensions are mm [in]) Installing the Interconnect/Field Wiring Application Advisory The sensor provides two signals, one for acceleration and another for velocity. The wires for each signal must be connected to the correct monitor type. If a signal is connected to the wrong monitor type, machinery protection will be lost and incorrect data will be reported. 4 The interconnect cable must be purchased separately. Refer to the datasheet at for more information. Step 1- Hand-tighten connector to the electronics. Step 2- Route cable Strap cable every 0.6 m [2 ft.] Avoid routing cable near power lines Avoid sharp corners

7 Step 3- Make electrical connections to the Bently Nevada monitor Consult local authorities for approved installation methods in hazardous areas Follow Figure 4 for electrical connections Current limit non-bently Nevada systems to 40 ma or less Installation Refer to the appropriate Bently Nevada monitor manual for detailed wiring and installation instructions Tightly secure all electrical connections CE Installation Notes Figure 4: Interconnect Field Wiring Cable Note: Unless otherwise specified, output will not deviate by more than 5% FSO (±0.25 Vdc). Test Description Reference Specification Performance Criteria Radiated Emission EN55011 Class B ESD Immunity EN Criteria A Radiated Immunity EN Criteria A Electrical Fast Transient Immunity EN Criteria A Surge Immunity EN Criteria A 5

8 High Temperature Velocity and Acceleration Sensor Operation and Maintenance Manual Conducted Immunity Magnetic Immunity EN EN Criteria A Criteria A CE Product Safety EN Meets directive These instructions are in addition to those contained elsewhere in this manual housing will be connected to ground field cable or equivalent will be used (see Figure 4) Shields will be connected to ground 6

9 Field Testing and Troubleshooting Field Testing and Troubleshooting Problem Cause Solution One Channel Output Bias Out of Specification -12 < Vbias < -8 Both Channels Output Bias Out of Specification -12 < Vbias < -8 Vibration amplitude low Vibration amplitude high Noise Faulty field wiring Fault Type 1: Field/Interconnect cable (see page 8) Swapped conductors Fault Type 1: Field/Interconnect cable (see page 8) Faulty sensor Fault Type 2: Sensor Fault (see page 9) Faulty power Check monitor or power supply for power Faulty field wiring Fault Type 1: Field/Interconnect cable (see page 8) Swapped conductors Fault Type 1: Field/Interconnect cable (see page 8) Faulty sensor Fault Type 2: Sensor Fault (see page 9) Channel type is swapped Fault Type 1: Field/Interconnect cable (see page 8) Channel polarity is switched Fault Type 1: Field/Interconnect cable (see page 8) Loose connection Fault Type 1: Field/Interconnect cable (see page 8) Loose sensor mounting Check and re-torque fasteners Improper bracket design Contact Bently Nevada Services Faulty sensor Fault Type 2: Sensor Fault (see page 9) Channel type is swapped Fault Type 1: Field/Interconnect cable (see page 8) Loose connection Fault Type 1: Field/Interconnect cable (see page 8) Loose sensor mounting Check and re-torque fasteners Improper bracket design Contact Bently Nevada Services Faulty sensor Fault Type 2: Sensor Fault (see page 9) Loss of case isolation Fault Type 3: Signals not Related to Machine Vibration (Noise) (see page 9) Ground loops Fault Type 3: Signals not Related to Machine Vibration (Noise) (see page 9) High voltage lines proximity Fault Type 3: Signals not Related to Machine Vibration (Noise) (see page 9) 7

10 High Temperature Velocity and Acceleration Sensor Operation and Maintenance Manual Fault Type 1: Field/Interconnect cable Interconnect cable is disconnected or connection is loose at the monitor. Visually verify that the sensor is connected to the correct monitor and to the correct electrical terminals. Verify terminals are tight. Interconnect cable is not connected or connection is loose at the sensor. Visually verify that the connector is tight at the sensor. Disconnect the interconnect cable from the monitor and measure the resistance between the following conductor pairs: Measurement Approximate Value Pin 1 to 6 (PWR to COM) 1MΩ <R measure <7MΩ Pin 2 to 3 (Vel+ to Vel-) 1MΩ <R measure <5MΩ Pin 4 to 5 (Accel+ to Accel-) 20kΩ <R measure <200kΩ Resistance outside this range could indicate a faulty cable or sensor. Note: We recommend using an ohmmeter with an open circuit voltage of less than 0.7Vdc for this test. Interconnect Cable is damaged: Shorted Visually inspect the interconnect cable for apparent damage. Disconnect the interconnect cable at both ends. Measure the resistance between conductor pairs and between each conductor and shield of the interconnect cable. Repeat measurement for each conductor until all conductor permutations have been measured. Resistance less than 10MΩ or an intermittent measurement could indicate a faulty cable or field wiring. Interconnect Cable is damaged: Open Visually inspect the interconnect cable for apparent damage. Disconnect the interconnect cable at both ends. Short the following conductor pairs and measure the resistance at the connector: Measurement Approximate Value Pin 1 to 6 (PWR to COM) R measure <100Ω Pin 2 to 3 (Vel+ to Vel-) R measure <100Ω Pin 4 to 5 (Accel+ to Accel-) R measure <100Ω Resistance greater than 100Ω could indicate a faulty cable or field wiring. Velocity and Acceleration Channels are switched. The velocity and acceleration channel DC output bias are similar and cannot be used to identify the channel. Visual verification is necessary. Abnormally low or high vibration readings could indicate reversal of these channel types. Cable conductors are switched Measure the following DC voltage at the monitor terminal: Measurement Pin 1 to 6 (PWR to COM) Pin 2 to 3 (Vel+ to Vel-) Pin 4 to 5 (Accel+ to Accel-) Approximate Value -24 ± 2 Vdc -10 ± 2 Vdc -10 ± 2 Vdc 8

11 Values outside this range could indicate wiring reversal. Field Testing and Troubleshooting Fault Type 2: Sensor Fault Sensor open or shorted Disconnect the interconnect cable from the sensor and measure the resistance between the following conductor pairs: (refer to Figure 4) Measurement Pin 1 to 6 (PWR to COM) Pin 2 to 3 (Vel+ to Vel-) Pin 4 to 5 (Accel+ to Accel-) Approximate Value 1MΩ <R measure <7MΩ 1MΩ <R measure <5MΩ 20kΩ <R measure <200kΩ Resistance outside this range could indicate a faulty sensor Note: We recommend using an ohmmeter with an open circuit voltage of less than 0.7Vdc for this test. Fault Type 3: Signals not Related to Machine Vibration (Noise) Note: The pins on the sensor connector can easily bend. Use care when performing the following maintenance practices. Sensor signal is not isolated, is shorted to the case, or has noise coupled to the signal. Disconnect sensor from interconnect cable. Measure resistance from connector pin 1,2,3,4,5 and 6 to case. Measurements less than 100 MΩ could indicate a faulty sensor. Loose or dirty connection at the sensor Disconnect the interconnect cable from the sensor. Clean the connector and check for frayed or broken insulation on the interconnect cable. Carefully clean the connector on the sensor. Hand tighten the interconnect cable to the sensor. Loose connection at the monitor Check the connections at the back of the monitor. Retighten if necessary. Ground differential Machine ground and signal ground should be at the same voltage potential. To check for this, remove the interconnect cable from the sensor. The interconnect cable still needs to be connected to the monitor. Measure the AC voltage between pin 6 (COM) of the interconnect cable and the sensor case. This voltage should be less than 1 volt. A higher voltage is a possible indication of a grounding problem external to the monitor and sensor. This problem must be corrected in order for the sensor to operate properly. 9

200150, & Accelerometers Bently Nevada* Asset Condition Monitoring

200150, & Accelerometers Bently Nevada* Asset Condition Monitoring 200150, 200155 & 200157 Accelerometers Bently Nevada* Asset Condition Monitoring Description The 20015x Accelerometers are general purpose, wide frequency, case-mounted seismic transducers designed for

More information

Caution. Description. Specifications and Ordering Information and Accelerometers

Caution. Description. Specifications and Ordering Information and Accelerometers R Specifications and Ordering Information 200350 and Accelerometers Description The 200350 and Accelerometers are general purpose, case-mounted seismic transducers designed for use with Trendmaster Pro

More information

and Accelerometers

and Accelerometers 200350 and 200355 Accelerometers Product Datasheet Bently Nevada* Asset Condition Monitoring Description The 200350 and 200355 Accelerometers are general purpose, casemounted seismic transducers designed

More information

and Accelerometers Bently Nevada* Asset Condition Monitoring

and Accelerometers Bently Nevada* Asset Condition Monitoring 200350 and 200355 Accelerometers Bently Nevada* Asset Condition Monitoring Description The 200350 and 200355 Accelerometers are general purpose, casemounted seismic transducers designed for use with Trendmaster*

More information

Hydro Stator End Winding Accelerometer System

Hydro Stator End Winding Accelerometer System Hydro Stator End Winding Accelerometer System Bently Nevada Asset Condition Monitoring Description The hydro Stator End Winding Accelerometer (SEW Accel) system provides a cost effective and reliable method

More information

Hydro Stator End Winding Accelerometer System

Hydro Stator End Winding Accelerometer System Hydro Stator End Winding Accelerometer System Bently Nevada* Asset Condition Monitoring Description The hydro Stator End Winding Accelerometer (SEW Accel) system provides a cost effective and reliable

More information

Load Cell Troubleshooting

Load Cell Troubleshooting VPG TRANSDUCERS Load Cells Application Note VPG-08 Scope Load cells are designed to sense force or weight under a wide range of adverse conditions; they are not only the most essential part of an electronic

More information

Installation Manual A Digital Tachometer. Part Number Rev. H (09/07)

Installation Manual A Digital Tachometer. Part Number Rev. H (09/07) Installation Manual 37506A Digital Tachometer Part Number 40585-01 Rev. H (09/07) 37506A Digital Tachometer Installation Manual Copyright 1988 Bently Nevada LLC All rights reserved. The information contained

More information

High Frequency SineWave Guardian TM

High Frequency SineWave Guardian TM High Frequency SineWave Guardian TM 380V 480V INSTALLATION GUIDE FORM: SHF-IG-E REL. January 2018 REV. 002 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation

More information

ENC 150 REFERENCE MANUAL ACU-RITE

ENC 150 REFERENCE MANUAL ACU-RITE ENC 150 REFERENCE MANUAL ACU-RITE ENC150 Page Introduction... 2 Mounting Preparation... 3 Mounting Information... 4 Encoder Dimensions... 5 Backup Spar Dimensions... 6 Mounting Requirements... 7 Typical

More information

ARM V FDBK ENSURE MOTOR IS NOT ROTATING DURING POWER UP STILL FAULTS? YES ENSURE ARMATURE WIRING IS ISOLATED FROM ANY OTHER POWER LEADS STILL FAULTS?

ARM V FDBK ENSURE MOTOR IS NOT ROTATING DURING POWER UP STILL FAULTS? YES ENSURE ARMATURE WIRING IS ISOLATED FROM ANY OTHER POWER LEADS STILL FAULTS? ARM V FDBK ENSURE MOTOR IS T ROTATING DURING POWER UP This fault can only happen in the first 3 seconds after power up. The processor looks at the armature voltage. The voltage needs to be near 0. Possible

More information

LOAD CELL TROUBLESHOOTING

LOAD CELL TROUBLESHOOTING Technical Notes LOAD CELL TROUBLESHOOTING The objective of this Technical Note is to perform a simple check to identify troubleshooting of a load cell on the field, by using simple instrumentation as a

More information

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING dv Sentry TM 208V 600V INSTALLATION GUIDE FORM: DVS-IG-E REL. January 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR 125-5 P/N 9168800100 Publication: 9168800990 Revision: J 03/09 INTRODUCTION This instruction manual provides information about the operation and installation

More information

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy NorthStar TM brand Instruction Manual SLIM Tach SL56 1.125 Thru-Shaft Diameter Magnetoresistive Encoder Designed for GE Wind Energy Patent Pending *791-1061-00* Rev. B Page 2 Table of Contents Chapter/Paragraph/Illustration

More information

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING SineWave Guardian TM 380V 600V INSTALLATION GUIDE FORM: SWG-IG-E REL. October 2018 REV. 003 2018 MTE Corporation High Voltage! Only a qualified electrician can carry out the electrical installation of

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

HI HLPT SERIES LOAD POINT ASSEMBLIES OPERATION AND INSTALLATION MANUAL

HI HLPT SERIES LOAD POINT ASSEMBLIES OPERATION AND INSTALLATION MANUAL HI HLPT SERIES LOAD POINT ASSEMBLIES OPERATION AND INSTALLATION MANUAL Corporate Headquarters 9440 Carroll Park Drive, Ste. 150 San Diego, CA 92121 Phone: (858) 278-2900 FAX: (858) 278-6700 Web-Site: http://www.hardysolutions.com

More information

Operation Manual Bently Nevada Asset Condition Monitoring

Operation Manual Bently Nevada Asset Condition Monitoring Operation Manual Bently Nevada Asset Condition Monitoring 330500 Velomitor Sensor, 330525 Velomitor XA Sensor, 330530 Radiation Resistant Velomitor Sensor Part Number 100076-01 Rev. H (08/07) 330500 Velomitor

More information

OASIS. Standby Instrument System. Installation Manual. Aerosonic Corporation September 18, N. Hercules Ave. Clearwater, FL USA

OASIS. Standby Instrument System. Installation Manual. Aerosonic Corporation September 18, N. Hercules Ave. Clearwater, FL USA OASIS Standby Instrument System Installation Manual Aerosonic Corporation September 18, 2012 1212 N. Hercules Ave. Clearwater, FL 33765 USA INSTALLATION MANUAL OASIS Original Aerosonic Standby Instrument

More information

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator

User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator User's Manual: Series 270I Model 270I Process Current Loop-Powered Isolator Table of Contents Page Introduction... 1 Description... 1 Specifications... 2 Installation... 3 Calibration... 4 General Maintenance...

More information

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL FORM: MX-TRM-E REL. September 2014 REV. 002 2014 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation

More information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Conforms to EN (TÜV) standards corresponding

More information

Active Controlled Cooling System

Active Controlled Cooling System Active Controlled Cooling System April 2011 3267 Progress Dr Orlando, FL 32826 www.apecor.com Preliminary www.apecor.com Table of Contents General Information... 3 Safety... 3 Introduction... 3 What s

More information

PL Submersible, Semi-Vortex, Water Feature Pump

PL Submersible, Semi-Vortex, Water Feature Pump TM M 2001992 Introduction Submersible, Semi-Vortex, Water Feature Pump This manual provides information and procedures to safely install, operate and maintain this TSURUMI model. For your own safety and

More information

PROVEX Installation Guide. Version 1.0

PROVEX Installation Guide. Version 1.0 Version 1.0 INTRODUCTION The scale must not be loaded beyond its capacity. Do not select a site where overweight load would have to maneuver to avoid crossing the platform. Avoid areas where the scale

More information

GROUP 17 CONTENTS WARNINGS REGARDING SERVICING OF SUPPLEMENTAL RESTRAINT SYSTEM (SRS) EQUIPPED VEHICLES

GROUP 17 CONTENTS WARNINGS REGARDING SERVICING OF SUPPLEMENTAL RESTRAINT SYSTEM (SRS) EQUIPPED VEHICLES 17-1 GROUP 17 CONTENTS ENGINE CONTROL 17-4 GENERAL DESCRIPTION 17-4 ENGINE CONTROL SYSTEM DIAGNOSIS 17-4 INTRODUCTION TO ENGINE CONTROL SYSTEM DIAGNOSIS 17-4 ENGINE CONTROL SYSTEM DIAGNOSTIC TROUBLESHOOTING

More information

1100 Series Piston Type Differential Pressure Gauges

1100 Series Piston Type Differential Pressure Gauges 1100 Series Piston Type Differential Pressure Gauges 1. Safety Before installing, check the Series Number and verify compatibility to the process media and temperature in contact with the wetted parts.

More information

Contents. 1. Preface Product Outline Model Number Construction Specifications Outline Drawings and Wiring diagram...

Contents. 1. Preface Product Outline Model Number Construction Specifications Outline Drawings and Wiring diagram... TY-KM31-001A 1/13 Contents 1. Preface.. 2 2. Product Outline.. 2 3. Model Number Construction.. 2 4. Specifications.. 3 5. Outline Drawings and Wiring diagram... 4 6. External Connection.. 10 7. Function

More information

Pressure Makeup Jockey Pump Controller

Pressure Makeup Jockey Pump Controller Hubbell Industrial Controls, Inc. A subsidiary of Hubbell Incorporated 4301 Cheyenne Dr. Archdale, NC 27263 Telephone (336) 434-2800 FAX (336) 434-2803 Instruction Manual Pressure Makeup Jockey Pump Controller

More information

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number: INSTRUCTION MANUAL FOR VOLTAGE REGULATOR Model: APR 125-5 Part Number: 9 1688 00 100 Publication Number: 9 1688 00 990 Revision H: 07/2001 CONTENTS SECTION 1 GENERAL INFORMATION...1-1 DESCRIPTION... 1-1

More information

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual Hydro-Flow Model 00 Fixed Insertion Vortex Flowmeter Installation and Operation Manual Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines 4 Mechanical Drawing:

More information

Weatherproof Tubular Slip Ring Assembly

Weatherproof Tubular Slip Ring Assembly Weatherproof Tubular Slip Ring Assembly Model B8-4.3W 8 circuit weatherproof slip ring Compact design Mounts on shafts up to 4.3 [109.2 mm] in diameter Permanently lubricated bearings Rugged stainless

More information

TORQUE TRANSDUCER TMHFB-*NM (for Torque Transducer) Instruction Manual. MinebeaMitsumi Inc. Sensing Device Business Unit

TORQUE TRANSDUCER TMHFB-*NM (for Torque Transducer) Instruction Manual. MinebeaMitsumi Inc. Sensing Device Business Unit TORQUE TRANSDUCER TMHFB-*NM (for Torque Transducer) Instruction Manual MinebeaMitsumi Inc. Sensing Device Business Unit Please read this manual thoroughly before attempting to use the equipment. Be sure

More information

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE

FL7M-A Series. Aluminum-chip Immunity DC 2-wire Type Cylindrical Proximity Sensors. Specifications. click FEATURES ORDER GUIDE 6 FL7M-A Series FEATURES Workpieces Reliably Sensed Even if Aluminum or Cast Iron Chips Accumulate on the Sensing Head. This DC 2-wire type proximity sensor can be directly connected to programmable controllers

More information

Inline Ultrasonic Flowmeter

Inline Ultrasonic Flowmeter M-1500 Series Installation and Operating Manual The M-1500 series is an inline primary flow sensor and externally mounted controller unit. The flow sensor is a straight through flow tube that uses Transit

More information

E.S.P. Embedded Sensing Probes for Motor Brushes

E.S.P. Embedded Sensing Probes for Motor Brushes E.S.P. Embedded Sensing Probes for Motor Brushes 2/13 Installation & Operating Manual MN609 Any trademarks used in this manual are the property of their respective owners. Important: Be sure to check www.baldor.com

More information

MODEL SIT -6E PAVEMENT-MOUNTED SNOW AND ICE SENSOR

MODEL SIT -6E PAVEMENT-MOUNTED SNOW AND ICE SENSOR MODEL SIT -6E PAVEMENT-MOUNTED SNOW AND ICE SENSOR DESCRIPTION The Snow Switch Model SIT 6E Pavement-Mounted Snow and Ice Sensor reliably detects snow and ice conditions on pavement surfaces when used

More information

CONTROL MICROSYSTEMS Power Supply. Hardware Manual

CONTROL MICROSYSTEMS Power Supply. Hardware Manual 5103 Power Supply Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support: 888-226-6876

More information

797V Piezoelectric Velocity Sensor

797V Piezoelectric Velocity Sensor 797V Piezoelectric Velocity Sensor Installation Manual (Product # : 9400-09M2A-103) This manual divides into the following sections: Section 1: Section 2: Installation of the 797V Piezoelectric Velocity

More information

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE 2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE For Diaphragm Dosing Pumps FEM 1.02_.55 / FEM 1.09_.55 Controller board package, without pump: ID 160536 Operating and Installation Manual It is important to

More information

Pulse Encoder Interface Kit For Use With FlexPak 3000 and WebPak 3000 DC Drives M/N 907FK0101

Pulse Encoder Interface Kit For Use With FlexPak 3000 and WebPak 3000 DC Drives M/N 907FK0101 Pulse Encoder Interface Kit For Use With FlexPak 3000 and WebPak 3000 DC Drives M/N 907FK0101 Instruction Manual D2-3302-3 The information in this manual is subject to change without notice. Throughout

More information

ESD5550 / 5570 Series Speed Control Units

ESD5550 / 5570 Series Speed Control Units ESD5550 / 5570 Series Speed Control Units 1 The speed control unit is rugged enough to be placed in a control cabinet or engine mounted enclosure with other dedicated control equipment. If water, mist,

More information

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010 INSTALLATION INSTRUCTIONS Revision A1 Rapid City, SD, USA, 01/2010 MODELS 201A 201A-9 2880 North Plaza Drive, Rapid City, South Dakota 57702 (800) 843-8848 (605) 348-5580 fax (605) 348-5685 BE SURE POWER

More information

MTU1 Series Isolated 1W Single & Dual Output SM DC/DC Converters

MTU1 Series Isolated 1W Single & Dual Output SM DC/DC Converters www.murata-ps.com MTU1 Series SELECTION GUIDE FEATURES Patent Protected UL60950 recognised Footprint over pins 0.69cm 2 Single & dual isolated output 1kVDC Isolation Hi Pot Test Efficiency up to 88% (Typ.)

More information

INSTALLATION & MAINTENANCE MANUAL

INSTALLATION & MAINTENANCE MANUAL A Subsidiary of Dynamic Instruments INSTALLATION & MAINTENANCE MANUAL A Subsidiary of Dynamic Instruments 3860 Calle Fortunada San Diego, CA 92123-1825 Phone: 1-(800) 821-5831 Web Site: hardyinst.com (858)

More information

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual Graham TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual Vari Speed S1000 Instruction Manual TABLE OF CONTENTS Introduction 4 Unit Features 5 Operating Conditions 6 Specifications 7 Ratings

More information

ENGINE GOVERNING SYSTEMS

ENGINE GOVERNING SYSTEMS ENGINE GOVERNING SYSTEMS ESD5400 Series Speed Control Unit INSTALLATION The speed control unit is rugged enough to be placed in a control cabinet or engine mounted enclosure with other dedicated control

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 80 Pressure 80.090 80.090 Rev. J 0/ English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation.

More information

Technical information for LFU20-Z07-3A-X2

Technical information for LFU20-Z07-3A-X2 Technical information for LFU20-Z07-3A-X2 Ultrasonic flow sensor and flow controller Applications: closed-loop flow control. Also requires fluid regulator (separate part) Ultrasonic flow sensor IN18796_LFU

More information

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter. Quick Reference ❶ Performance Data Pages

More information

Sensing distance. 4mm. 4mm. 7mm. 12mm. 20mm

Sensing distance. 4mm. 4mm. 7mm. 12mm. 20mm DC2-wire Square Proximity Sensors FL2R/SSeries This DC2-wire Square Proximity sensor Can Be Directly Connected to Programmable Controllers and Units. Wide Range of Models Available. Reduced wiring costs

More information

182T and T182T Back-Up Alternator System ICA Revision: Date: 17 September 2008

182T and T182T Back-Up Alternator System ICA Revision: Date: 17 September 2008 Document Number: NC-08-034 Title: 182T and T182T Back-Up Alternator System ICA Revision: C Date: 17 September 2008 Name Signature Date Author Erik Pederson Signed Copy On File 9/17/08 Approved Erik Pederson

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 8450 Pressure English 8450.090 8450.090 Rev. G /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents

More information

Signet Temperature Transmitter

Signet Temperature Transmitter Signet 80 Temperature English 80.090 80.090 Rev. G /0 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.

More information

Air Gap Transducer System

Air Gap Transducer System Part Number 167684-01 Revision A, October 2004 Air Gap Transducer System Manual R 4000 Series Air Gap Sensor System Manual Copyright 2004 General Electric Company. All Rights Reserved. The information

More information

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual Hydro-Flow Model 00 Retractable Insertion Vortex Flowmeter Installation and Operation Manual Table of Contents Model and Suffix Codes. Theory and Identification.. Installation Guidelines Mechanical Drawing:

More information

Instruction Manual. for Heating Cables and Cold Leads Type and Catalogue no and Hemstedt GmbH.

Instruction Manual. for Heating Cables and Cold Leads Type and Catalogue no and Hemstedt GmbH. Instruction Manual for Heating Cables and Cold Leads Type 68994- and 68997- Catalogue no. 68994- and 68997- Hemstedt GmbH Schleicherweg 19 D-74336 Brackenheim-Botenheim Phone +49 (7135) 9898-0 Fax +49

More information

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING Matrix AP 400V 690V INSTALLATION GUIDE FORM: MAP-IG-E REL. May 2017 REV. 002 2017 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation of this filter.

More information

EVS RP6020. Instruction Manual

EVS RP6020. Instruction Manual Instruction Manual TDK Lambda BEFORE USING THE PRODUCT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product.

More information

Porta-Tronic. Portable Scales. INSTALLATION GUIDE Version 2.0

Porta-Tronic. Portable Scales. INSTALLATION GUIDE Version 2.0 Porta-Tronic Portable Scales INSTALLATION GUIDE Version 2.0 GSE Porta-Tronic Installation Guide Copyright 2008 GSE. All rights reserved. Published by: GSE 1525 Fairlane Circle Allen Park, MI 48101 www.gse-inc.com

More information

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320 Inlet Controller SB 2000 USER'S MANUAL AUTO OPEN MANUAL PUSH TO SEARCH NEXT STAG E CLOSE Aerotech, Inc. FORM: QM 1320 4215 Legion Dr. Mason, MI 48854-1036 USA Rev. 3, Sept. 1997 Ph. (517) 676-7070 Fax

More information

5001TCP SPEED CONTROLLER

5001TCP SPEED CONTROLLER VARIABLE SPEED DRIVE CONTROLLER INSTALLATION AND SETTING UP MANUAL 5001TCP SPEED CONTROLLER With PC101 Torque Limit Control WARNING Disconnect all incoming power before working on this equipment. Follow

More information

Trouble Shooting Instructions

Trouble Shooting Instructions Customer: Date: Trouble Shooting Instructions Electroair Acquisition Corp. 317 Catrell Dr., Suite #2 Howell, MI 48843 USA Ph: 517-552 552-9390 Fax: 517-552 552-9391 Email: sales@electroair.net Electroair

More information

ENGINE AND EMISSION CONTROL

ENGINE AND EMISSION CONTROL 17-1 GROUP 17 ENGINE AND EMISSION CONTROL CONTENTS ENGINE CONTROL.......... 17-3 GENERAL DESCRIPTION...... 17-3 ENGINE CONTROL SYSTEM DIAGNOSIS.................. 17-3 INTRODUCTION TO ENGINE CONTROL SYSTEM

More information

Operations Manual. Zero Speed Switch Sensor Model ZS09P

Operations Manual. Zero Speed Switch Sensor Model ZS09P Zero Speed Switch Sensor Model ZS09P The must be referred to for correct installation. Failure to comply with the shall void all warranties and liabilities. Overview The Phares Electronics Model ZS09P

More information

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09 HAND CRANK & MOTORIZED POWER CORD REELS: SERIES 1125PC SERIES: 1125PC HAND CRANK SERIES: 1125PC MOTORIZED COXREELS The technical data and images which appear in this manual are for informational purposes

More information

AXD 530 MicroManometer

AXD 530 MicroManometer OWNER S MANUAL AXD 530 MicroManometer A TSI Company Table of Contents Features 2 Using the AXD530 Safely 3 Getting Started 4 Installing Batteries 4 Preparing the Instrument 4 Attaching the Optional Pitot-Static

More information

MTU2 Series Isolated 2W Single & Dual Output SM DC/DC Converters

MTU2 Series Isolated 2W Single & Dual Output SM DC/DC Converters www.murata-ps.com MTU2 Series SELECTION GUIDE FEATURES Patent Protected UL 9 Recognised Footprint over pins.69cm 2 Single & dual isolated output 1kVDC Isolation Hi Pot Test Efficiency up to 85% (Typ.)

More information

CALTRAP INSTALLATION AND OPERATIONS MANUAL

CALTRAP INSTALLATION AND OPERATIONS MANUAL INSTALLATION AND OPERATIONS MANUAL NOTE Please read this entire installation and operations manual before energizing the. Safety Considerations: Installing and servicing capacitor equipment can be hazardous.

More information

FTM-L SERIES SINGLE OR TWIN DIRECT STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE PARTS AND SERVICE MANUAL

FTM-L SERIES SINGLE OR TWIN DIRECT STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE PARTS AND SERVICE MANUAL FTM-L SERIES SINGLE OR TWIN DIRECT STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE PARTS AND SERVICE MANUAL EFFECTIVE SEPTEMBER 19, 2014 Superseding All Previous Parts Lists. The Company reserves

More information

Hydro-Flow Model 2200 Installation and Operation Guide B

Hydro-Flow Model 2200 Installation and Operation Guide B Hydro-Flow Model 2200 Installation and Operation Guide 5700507-B Contents: Understanding and Identifying Your Flow Meter 1 Installing Your Flow Meter 3 Making Electrical Connections. 7 Mechanical and Electrical

More information

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure. Guard Lock Safety-door Switch Protective Doors Are Locked Until Machines Completely Stop Operating A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety

More information

Installation Instructions for SINGLE COLOR 24V LINEAR LED NEON

Installation Instructions for SINGLE COLOR 24V LINEAR LED NEON Installation Instructions for SINGLE COLOR 24V LINEAR LED NEON LLI-N2.9W Prior to installation, please confirm that you have the required system components listed below. LED Neon Flow Extrusions/Lens (Optional)

More information

5001TCP SPEED CONTROLLER

5001TCP SPEED CONTROLLER INSTALLATION AND SETTING UP MANUAL 5001TCP SPEED CONTROLLER WARNING Disconnect all incoming power before working on this equipment. Follow power lockout procedures. Use extreme caution around electrical

More information

BML-S1B0-Q _-M _-_0-KA. User's Guide. english

BML-S1B0-Q _-M _-_0-KA. User's Guide. english english User's Guide Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.f. Germany Phone +49 (0) 71 58/1 73-0 Fax +49 (0) 71 58/50 10 Servicehotline +49 (0) 71 58/1 73-3 70 E-Mail: balluff@balluff.de

More information

SERVICE MANUAL Defender Bases Dry-use (B Series) Wet-use (V Series)

SERVICE MANUAL Defender Bases Dry-use (B Series) Wet-use (V Series) SERVICE MANUAL Defender Bases Dry-use (B Series) Wet-use (V Series) Ohaus Corporation, 7 Campus Drive, Suite 310, Parsippany, NJ 07054 (973) 377-9000 SERVICE MANUAL Defender Bases Dry-Use (B Series) Wet-Use

More information

POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation

POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation (SF3 pending) (SF3 pending) (SF3 pending) POLARISED, MONOSTABLE SAFETY RELAY with (mechanical linked) forced contacts operation SF-RELAYS π.098±.0.098±.0.098±.0 5.0.984 6.5±0.3.650±.0 33±0.3.99±.0 6.5±0.3.650±.0

More information

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS XX and XX Series Electric Attitude Indicator

INSTALLATION MANUAL AND OPERATING INSTRUCTIONS XX and XX Series Electric Attitude Indicator INSTALLATION MANUAL AND OPERATING INSTRUCTIONS 4300-3XX and 4300-5XX Series Electric Attitude Indicator MID-CONTINENT INST. CO., INC MANUAL NUMBER 9015692 Copyright 2003 Mid-Continent Instrument Co., Inc.

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

Click Here for Printable PDF File. CHAPTER 3 - BASIC INFORMATION for PERFORMING HYDRAULIC SYSTEM MAINTENANCE

Click Here for Printable PDF File. CHAPTER 3 - BASIC INFORMATION for PERFORMING HYDRAULIC SYSTEM MAINTENANCE HWH Online Technical School Lesson 1: Introduction to Hydraulics Chapter 3 - "BASIC INFORMATION for PERFORMING HYDRAULIC SYSTEM MAINTENANCE" (Filename: ML57000-012-CH3.DOC Revised: 22APR16) Click Here

More information

LS200 Series Instruction Manual

LS200 Series Instruction Manual LS200 Series Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage may lead to an electrical shock, damage to the unit

More information

PETERBILT MIRRORS SERVICE MANUAL

PETERBILT MIRRORS SERVICE MANUAL PETERBILT 579 - MIRRORS SERVICE MANUAL Copyright Lang-Mekra North America LLC 2014 FOREWORD Read this manual carefully before operating. For the most recent version of this manual visit: www.lang-mekra.com.

More information

DVFL2800S Series HIGH RELIABILITY HYBRID DC-DC CONVERTERS DESCRIPTION FEATURES

DVFL2800S Series HIGH RELIABILITY HYBRID DC-DC CONVERTERS DESCRIPTION FEATURES HIGH RELIABILITY HYBRID DC-DC CONVERTERS DESCRIPTION The DVFL series of high reliability DC-DC converters is operable over the full military (-55 C to +125 C) temperature range with no power derating.

More information

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2 Solid-state Contactor (New Heat Sink Construction) G3PB Space and working time saved with new heat sink construction. Series now includes 480-VAC models to allow use in a greater range of applications.

More information

DC2-Wire Unshielded Cylindrical Proximity Switches

DC2-Wire Unshielded Cylindrical Proximity Switches DC2-Wire Unshielded Cylindrical Proximity Switches FL7M Series Unshielded switches achieve especially long sensing distances Long sensing distance (2 times the sensing distance of a regular FL7M) DC2-wire

More information

DIAGNOSIS AND TESTING

DIAGNOSIS AND TESTING 414-00-1 Charging System General Information 414-00-1 DIAGNOSIS AND TESTING Charging System The charging system voltage is controlled by the PCM. The generator charges the battery, and at the Special Tool(s)

More information

Model Number Structure

Model Number Structure Solid State Relays (Single-phase) G3PB New Single-phase Solid State Relays with Compact Size for Heater Control Slim models with a thickness of only 22.5 mm are also available. Compact design achieved

More information

Low Pressure Sensor. Overview. Specifications. Installation and Operation

Low Pressure Sensor. Overview. Specifications. Installation and Operation Overview The Low Pressure Sensor with display measures building pressure, air velocities and volumes. The heart of the unit is a micro-machined silicon pressure sensor. The unit includes a static pressure

More information

DS1 Plug-In Digital Signal Cross-Connect (PIX-DSX-1) 19-Inch Shelf Kit Installation Instructions

DS1 Plug-In Digital Signal Cross-Connect (PIX-DSX-1) 19-Inch Shelf Kit Installation Instructions DS Plug-In Digital Signal Cross-Connect (PIX-DSX-) 9-Inch Shelf Kit Installation Instructions Contents Page INTRODUCTION... Revision History... List of Changes... Trademark Information... Related Publications...2

More information

RP Instruction Manual

RP Instruction Manual Instruction Manual TDK Lambda BEFORE USING THE PRODUCT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product.

More information

100A Series Low Power FM Antenna

100A Series Low Power FM Antenna Installation Instructions 100A Series Low Power FM Antenna Types 100A-1M, 100A-2F, 100A-2F-HW 20100326001_AEN Revision 03 Notice The installation, maintenance, or removal of antenna systems requires qualified,

More information

Signal Conditioner WEB CONTROL PRODUCTS SC100 FORM NO. L B User Manual. MTY (81)

Signal Conditioner WEB CONTROL PRODUCTS SC100 FORM NO. L B User Manual. MTY (81) WEB CONTROL PRODUCTS User Manual Signal Conditioner SC100 FORM NO. L-63-B-0304 1 FORM NO. L-63-B-0304 In accordance with Nexen s established policy of constant product improvement, the specifications contained

More information

OWNERS MANUAL JANUARY 2007 ISO

OWNERS MANUAL JANUARY 2007 ISO Manufacturer of Dimensions TM Inverters 4467 White Bear Parkway St. Paul, MN 55110 Phone: 651-653-7000 Fax: 651-653-7600 E-mail: inverterinfo@sensata.com Web: www.dimensions.sensata.com 121231B OWNERS

More information

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

M9106-AGx-2N0x Series Electric Non-spring Return Actuators Installation Instructions M9106AGx-2N0x Issue Date 08/31/01 M9106-AGx-2N0x Series Electric Non-spring Return Actuators Installation IMPORTANT: The M9106-AGx-2N0x Series actuator is intended to control

More information

SITRANS AS 100. Instruction Manual September 2001 ITRANS AS 100

SITRANS AS 100. Instruction Manual September 2001 ITRANS AS 100 SITRANS AS 100 Instruction Manual September 2001 ITRANS AS 100 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the

More information

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited. SERVICE MANUAL ELECTRIC BRAISING PANS (30 & 40 GALLON) VE30 VE40 ML-126849 ML-126850 VE40 SHOWN - NOTICE - This Manual is prepared for the use of trained Vulcan Service Technicians and should not be used

More information

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY 222 W. Memorial Road, Oklahoma City, OK 73114-2317 Phone: 1-800-624-7697 Fax: 405-755-8425 www.magpowr.com E-mail: magpowr@magpowr.com INSTRUCTION MANUAL MODEL PS-24 24 VDC POWER SUPPLY All of the information

More information

OPERATOR TROUBLESHOOTING GUIDE

OPERATOR TROUBLESHOOTING GUIDE OPERATOR TROUBLESHOOTING GUIDE ABOUT THE TROUBLESHOOTING GUIDE This document is provided for the use of qualified operator installers. The installer should familiarize themselves with this guide Options

More information

MSD-8 Plus Ignition PN 7805

MSD-8 Plus Ignition PN 7805 MSD-8 Plus Ignition PN 7805 Note: Solid Core spark plug wires cannot be used with an MSD Ignition. Parts Included: 1 - MSD-8 Plus Ignition 1 - Mag Pickup Extension Harness, PN 8860 4 - Vibration Mounts

More information