1 TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL TKS-5001, TKS , TKS-6001, TKS-7001 Pneumatic Temperature Transmitters Room General Instructions GENERAL INFORMATION For proportional temperature control, used with RKS series receiver-controllers, for proportional control of pneumatically actuated valves, dampers and similar devices in HVAC systems. May be used with one or more calibrated gauges for continuous temperature indication at local or remote stations. Construction: Bimetal element, non-adjustable. Shipping Ambient Temperature Limits: -20 to 150 F (-29 to 65 C). Air Connections: 5/32" dia. spring reinforced plastic tube. TKS , 1/4" barbed fittings for plastic tubing. TKS-6001, barbed fitting for 5/32" plastic tube. Air Consumption For Sizing Air Compressor:.024 scfm (11.3 ml/s); TKS ,.040 scfm (18.9ml/s). Air Capacity for Sizing Air Mains: 50 scim (13.7 ml/s); TKS , 100 scim (27.3 ml/s). Supply Pressure (Indication Only): 20 psig (138 kpa) nominal. 18 psig (124 kpa) minimum. Maximum Safe Supply Pressure: 30 psig (207 kpa). Mounting Dimensions: Wall: 4-3/8" (111 mm) high x 2-3/4" (70mm) wide x 1-5/8" (41 mm) deep. Aspirating: 5" (127 mm) high x 3-1/2" (89 mm) wide x 2-1/2" (64 mm) deep. Cover, 5-1/2" (140 mm) x 4" (102 mm). Diffuser: Requires 3/8" (10 mm) minimum to 7/8" (22 mm) maximum diameter hole in the diffuser face. Unit protrudes from face approximately 1-1/2" (38 mm). Light Troffer: 3/8" (10 mm) x 3/8" (10 mm) x 3" (76 mm). Mounting Fittings: Order separately for type of wall construction. OPTIONS None. ACCESSORIES AT-504 Plaster hole cover (small) AT-505 Surface mounting base AT-506 Pneumatic wall box fitting (two tubes) used for mounting AT under cover of TKS-5001 AT-509 Wall box required for TKS AT-516 Pneumatic wall box fitting (one tube) AT tee restrictor for 5/32" plastic tubing AT tee restrictor for 1/4" plastic tubing AT-1103 Wire guard AT-1104 Cast aluminum guard AT-1105 Plastic guard AT-1155 Plastic guard AT-1165 Plastic guard AT restrictor (white) AT Adaptor 1/4" plastic to 5/32" plastic AT Adaptor 3/16" copper or 1/4" copper with 1/4" solder coupling (not included) to 5/32" plastic AKS-6000 Stem mounted back connected receiver gauges AKS-9000 Flush panel mounted with U clamp receiver gauges TOOL-100-xxx Calibration fixture Table-1 Part Number Action Mounting TKS-5001 TKS TKS-6001 TKS-7001 Direct Acting *Has beige plastic cover as standard. Wall* Aspirating Light Troffer Diffuser Range F ( C) Non-Adj (10-38) Output Signal psig (kpa) 3-15 (21-103) Printed in U.S.A. 8/06 Copyright 2006 TAC All Rights Reserved. F

2 PRE-INSTALLATION Check the carton and device for signs of damage. TKS-5001 Transmitter is shipped with mounting screws and one inch copper tubes. INSTALLATION MOUNTING FITTINGS Use AT-516 wall box fitting for surface mounting on all surfaces and flush mounting on plastered or stud walls. Use standard 2" x 4" box for flush mounting on masonry walls (available through most electrical supply houses). Mounting Location TKS-5001, TKS Locate the transmitter where it will be exposed to unrestricted natural air circulation representative of the average conditions. The transmitter should not be located near sources of heat or cold such as lamps, motors, sunlight, concealed ducts or pipes. TKS The pneumatic aspirated thermostat fitting is designed for flush mounting. When installing the wall box (AT-509), make sure that the front of the box is flush with the finished wall surface. The box is normally held in place by concrete block or masonry walls. Two holes are provided in the box for installation in lath-and-plaster walls. Using these two holes, the box may be attached to the lath, wall studs, etc., by means of wire, nails, or screws. Figure-1 Note: When using the box in lath-and-plaster walls, seal around the fasteners after mounting the box to prevent wall air currents from entering the box. If desired, this fitting may be surface mounted. TKS-5001 TKS-6000 Troffer and TKS-7001 Diffuser Transmitters See specific installation instructions (page 4) for proper location. RESTRICTORS A remote in-line restrictor is required when used for indication only or if the transmitter is more that 200 ft. (61 m) from the receiver controller. Use an AT kit if restrictor is to be mounted under the cover. Figure-2 Mounting of TKS-5001 to AT-516 Wall Fitting See Figure Remove and discard the cardboard cover plate on the wall box fitting, after the wall is plastered. 2. If the transmitter plastic tubing is too long for easy coiling in the wall box, it can be cut to length. Cut at a 45 angle for ease in inserting the tubing into the O ring seal. Be sure to cut the coil spring off with the tubing. 3. Remove and discard the short plug inserted in the connector head of the wall box fitting. 4. Insert the tube in the center hole in the connector. 2 Copyright 2006 TAC All Rights Reserved. F

3 Caution: Do not use any lubricant on the plastic tubing. 5. Remove cover. Fasten the transmitter to the wall box with the two mounting screws provided. Tighten the screws evenly. 6. Replace cover and tighten cover screw. Figure-5 Figure-3 Mounting of TKS-5001 to an Electrical Switchbox in a Masonry Wall See Figure Connect transmitter plastic tubing to field tubing that has been brought through the knockout holes (See Figure 4). Rotate the plastic tubing slightly back and forth and push firmly onto the adapter. Caution: Do not lubricate the outside of the plastic tubing. Figure-4 2. Remove cover. Place the transmitter against the switchbox and pull the excess plastic tubing through the transmitter backplate. Mounting of TKS-5001 on AT-506 WAll Box Fitting Or Electrical Switchbox with Restrictor Tee Under The Cover (Requires AT Kit - See Figure 5) 1. Remove cover. 2. Remove 5/32" tube on TKS-5001 from mounting plate. Caution: Do not remove the end which is in the tube (connected to sensing element). 3. Cut the tube and spring 2-1/2" (65 mm) from the tygon tubing. 4. Connect the tube to one side of the restrictor tee. 5. Connect the black tube to the main connection of the restrictor tee. Insert one spring into the tube. Cut off excess spring. Insert the black tube through a hole in the left hand side bracket and then through the large oblong hole in the back plate. 6. Connect the white tube to the remaining side connection of the restrictor tee. Insert the other spring into the tube and cut off and excess spring. Insert the white tube through a hole on the right hand bracket next to the transmitter, and then insert through the oblong hole in the back plate. 7. Install the insulator card by inserting the black tube through the left hand hole and the white tube through the right hand hole. 8. Insert the black tube into the left hand hole in the wall fitting or connect to the main line. 9. Insert the white tube into the right hand hole in the wall fitting or connect to the transmitter (branch) output line. 10. Attach the transmitter back plate to the wall box with screws provided. 11. Replace cover and tighten cover screw. Caution: Make certain tubing does not detach from adaptor or transmitter 3. Fasten the transmitter mounting plate to the switchbox with the screws provided. Tighten the screws evenly. 4. Replace cover and tighten cover screw. F Copyright 2006 TAC All Rights Reserved. 3

4 Mounting of TKS Aspirating Transmitter in an AT-509 Wall Box See Figure 6. Mounting of TKS-6001 on Light Troffer Figure-7 Locating TKS-6001 in Troffer End Opposite Exhaust Grill. Figure-6 1. Remove and discard the cardboard cover plate on the wall box. (The cardboard cover protects the fitting while the wall is being plastered.) 2. Attach the transmitter tubing to the field tubing. 1/4" barbed fittings provided for installation to field plastic tubing. If adapting transmitter tubing to 1/4" copper (See Figure 4): a. Remove factory installed barbed fitting from 5/32" plastic tubing. b. Solder AT adaptor to 1/4" solder coupling. c. Attach 5/32" plastic tubing to AT Fasten the transmitter mounting plate to the mounting box with (2) 1/4" #6-32 filister screws supplied. Tighten the screws evenly. 4. Place the aspirating tube over the aspirating nozzle. 5. Install cover plate on box making sure that the aspirating tube is positioned in the hole located in the bottom air baffle (which is part of the cover). 6. Fasten cover plate with four spanner screws provided, making sure that the gasket on the cover seals against the edge of the wall box. Figure-8 Mounting Location The transmitter must be located in the return air grille opposite the fixture exhaust air opening when mounting in recessed combination light fixture/air diffuser (See Figure 7). A 1/2" knockout is provided in the correct end of the light fixture shell for the admittance of the transmitter. Light Fixtures come equipped with the return air grille assembly attached to the hinged access door (See Figure 8). Mounting Barbed end fitting for 5/32" plastic tubing. Run shortest length of 5/32" plastic tubing possible from transmitter [no more than 3 ft. (1 m)] before connecting to 1/4" plastic tubing. Caution: When inserting the transmitter in the return air grille, make sure that the O rings isolate the transmitter from the fixture shell. See location of O rings on transmitter in identification photo. 4 Copyright 2006 TAC All Rights Reserved. F

5 Table-2 Sensor Location and Figure Showing Mounting Details. 8 9 Fig. 13 Air Patterns (As Viewed from Diffuser Face) Number is Air Pattern Designation When Ordering Figure-9 Transmitter Mounted in Perforated Face Ceiling Diffuser Model PB or PS. Figure-10 Room Air Induced Over Transmitter by Discharged Air. Mounting of TKS-7001 Diffuser Transmitter Transmitter should be mounted to the face of the ceiling diffuser so that it projects downward into the room (See Figure 9). If the diffuser has an adjustable pattern, the discharge air direction must be adjusted to a horizontal pattern. This will insure a representative sample of room air over the element (See Figure 10). The transmitter will not perform satisfactorily if the discharge is adjusted to a vertical pattern. A 7/16" (11mm) hole is required in the diffuser face for mounting. The SFS and SFB louver faced diffusers are available in nine air patterns, both in the square and rectangular design. For proper installation, use Table-2 which shows transmitter location and the mounting figure referred to in the installation procedure. Figure-11 Table-2 Sensor Location and Figure Showing Mounting Details. Air Pattern Center of Diffuser Center of Side with No Air Throw Corner Opposite Air Throw End Opposite Air Throw Figure-12 Sq. Rect. Sq. Rect. Sq. Rect. Sq. Rect. 0 Fig. 11 Fig Fig Fig Fig. 11 Fig.13 Figure-13 F Copyright 2006 TAC All Rights Reserved. 5

6 Transmitter Mounting Procedure Using APNS-107 Kit 1. Drill a 5/16" (8 mm) hole for transmitter tubing. a. Figure 11. Locate hole center on an angled surface about 5/16" (8 mm) from an edge of the 1/2" (13 mm) square so as to avoid drill contact with the welded center plate mounting brackets. b. Figure 12. Locate hole center on one louver about 5/16" (8 mm) from junction of two center back to back louvers. c. Figure 13. Locate hole center on an end louver about 1/2" (13 mm) from the junction of the louver and the mounting flange. 2. Bring field tubing through the 5/16" (8 mm) hole. If required, remove the louver assembly from the mounting flange. 3. Center the APNS-107 bracket over the 5/15" (8 mm) hole (use as a template) and drill 1/8" (3.2 mm) holes for the mounting screws. a. Figure 11. Drill two holes near edges of square center plate. b. Figure 12. Drill two holes, one each on bottom edge of back to back louvers. c. Figure 13. Drill one hole on end louver. 4. Assemble the transmitter to APNS-107 bracket as shown in Figures 10, 12, and 13. a. Figure 11. Cut off one side of APNS-107 as shown. 5. Make field connections to transmitter and push tubing up through the 5/16" (8 mm) hole. a. Wrap friction or electrical tape around the tubing and fill the 5/16" (8 mm) hole, preventing direct primary air passage over the sensor. 6. Attach APNS-107 as shown in Figures 11, 12, and 13 using #6 screws. a. Figure 13. Cover the crack between the end louver and mounting flange at least 12" (.3 m) on each side of the sensor. A 24" (.6 m) length of 3/4" (20 mm) tape stuck to the mounting flange can be used. 7. The transmitter installation is complete. FIELD CHECKOUT Dual Input Controller with Two Transmitters 1. Connect the calibration panel (Tool-100) into ports 1 and 2 of the receiver-controller and temperature transmitters as shown in Figure Move toggle switches to the up (transmitter) position. 3. Measure the temperature at each transmitter with an accurate thermometer. (Make certain the transmitters are measuring a stable condition.) 4. Note the readings on the calibration panel gauges for the 50 to 100 F (10 to 38 C) range of transmitters used and compare these to the temperatures measured at the transmitters. Readings should be within +4 F (2.2 C). Replace the transmitter if the readings are not within these limits. Note: With toggle switches in the down (calibration) position, various temperatures can be simulated by using the manual adjuster. Figure-14 Receiver-Controller with Single Transmitter Located More Than 200 ft. (60 m) Up to Maximum of 1000 ft. (300 m) 1. Connect the calibration panel (Tool-100) to main air supply, the receiver-controller port 1 (note that restrictor is blocked) and AT restrictor tee as shown in Figure Move toggle switch to the up (transmitter) position. 3. Measure the temperature at each transmitter with an accurate thermometer. (Make certain the transmitters are measuring a stable condition.) 4. Note the readings on the calibration panel gauges for the 50 to 100 F (10 to 38 C) range of transmitters used and compare these to the temperatures measured at the transmitters. Readings should be within +4 F (2.2 C). Replace the transmitter if the readings are not within these limits. Note: With toggle switch in the down (calibration) position, various temperatures can be simulated by using the manual adjuster. 6 Copyright 2006 TAC All Rights Reserved. F

7 ADJUSTMENTS Figure-15 No field adjustments should be made on the transmitter. Caution: Field adjustments will void factory warranty. MAINTENANCE This is a quality product. Regular maintenance of the total system is recommended to assure sustained optimum performance. REPAIR DO NOT field repair. The transmitter should be replaced if it is causing the system to malfunction. F Copyright 2006 TAC All Rights Reserved. 7

8 Copyright 2006, TAC All brand names, trademarks and registered trademarks are the property of their respective owners. Information contained within this document is subject to change without notice. TAC 1354 Clifford Avenue P.O. Box 2940 Loves Park, IL F

2211 Series. Application. Features. One-Pipe Pneumatic Room Thermostats General Instructions SPECIFICATIONS

2211 Series. Application. Features. One-Pipe Pneumatic Room Thermostats General Instructions SPECIFICATIONS TAC 1354 Clifford Avenue P. O. Box 940 Loves Park, IL 6113-940 www.tac.com 11 Series One-Pipe Pneumatic Room s General Instructions Application The 11 Series Pneumatic Room is designed for proportional

More information

TK-6024, TK-6124, TK-8024, TK-8124

TK-6024, TK-6124, TK-8024, TK-8124 TK-6024, TK-6124, TK-8024, TK-8124 Pneumatic Bulb Thermostats General Instructions APPLICATION For proportional temperature control of pneumatic valves and actuators to maintain air or liquid temperatures

More information

AK Application. Features. Applicable Literature. Positive Positioner Pneumatic Relay General Instructions

AK Application. Features. Applicable Literature. Positive Positioner Pneumatic Relay General Instructions TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com Positive Positioner Pneumatic Relay General Instructions Application The Positive Positioner Pneumatic Relay is used to accurately

More information

TS , -850 Series TS , -850 Series TS-57031, TS

TS , -850 Series TS , -850 Series TS-57031, TS TS-5711-770, -850 Series TS-57011-770, -850 Series TS-57031, TS-57031-850 Electronic Room Temperature Sensors General Instructions Application These sensors provide electronic sensing of room temperature

More information

TS Series TS Series

TS Series TS Series TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com TS-6700-850 Series TS-5700-850 Series Electronic Remote Temperature Sensors General Instructions APPLICATION Electronic thermistor

More information

MK-6600 Series, MK-6800 Series, and MK-6911

MK-6600 Series, MK-6800 Series, and MK-6911 MK-6600 Series, MK-6800 Series, and MK-6911 Pneumatic Valve Actuators General Instructions Application These valve actuators, with a 50 sq. in. (323 cm 2 ) effective diaphragm area, are used for proportional

More information

CP-8551 & CP Application. Features. Applicable Literature. Electronic to Pneumatic Transducers General Instructions

CP-8551 & CP Application. Features. Applicable Literature. Electronic to Pneumatic Transducers General Instructions CP-8551 & CP-8552 Electronic to Pneumatic Transducers General Instructions Application The CP-8551 and CP-8552 transducers receive a variable electronic input signal and produce a 3 to 15 psig (21 to 103

More information

MA-5200 Series MA-5300 Series

MA-5200 Series MA-5300 Series MA-5200 Series MA-5300 Series Two-Position Actuators General Instructions Application The MA-5200 series and MA-5300 series actuators are used for two-position control of valves and dampers which require

More information

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS

SLC-811X Series. Single Loop Proportional Temperature Controller General Instructions APPLICATION SPECIFICATIONS SLC-811X Series TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com Single Loop Proportional Temperature Controller General Instructions APPLICATION Electronic temperature controller

More information

THC-2, THC-3, THCR-4, THCR-5. Enthalpy Control. General Instructions APPLICATION SPECIFICATIONS. ACCESSORIES None

THC-2, THC-3, THCR-4, THCR-5. Enthalpy Control. General Instructions APPLICATION SPECIFICATIONS. ACCESSORIES None THC-2, THC-3, THCR-4, THCR-5 Enthalpy Control General Instructions APPLICATION For ON-OFF (two position) low voltage control of the amount of air brought into the cooling system with respect to the total

More information

AV-430. Application. Features. Applicable Literature. Valve Linkage for Pneumatic Actuators General Instructions

AV-430. Application. Features. Applicable Literature. Valve Linkage for Pneumatic Actuators General Instructions AV-430 Valve Linkage for Pneumatic s General Instructions Application The AV-430 valve linkage is used to field assemble MK-66X1, MK-68X1, and MK-6911 actuators, as well as the obsolete MK-47X1 actuators,

More information

Distributed By: M&M Control Service, Inc Product Product Code Technical Instructions Page #

Distributed By: M&M Control Service, Inc Product Product Code Technical Instructions Page # Table of Contents Product Product Code Technical Instructions Page # Pneumatic Air Station Equipment 201/656/908 155-005/049/086/137P25 H-3 Pressure Gauges GA142AP 155-025P25 H-7 External Restrictors 184

More information

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com MP-5400 Series Electronic Positive Positioning Hydraulic Actuator General Instructions Application The MP-5400 Series Actuators

More information

TSMN-90xxx Series TSMN TSMN TSMN Electronic Room Temperature Sensor General Instructions

TSMN-90xxx Series TSMN TSMN TSMN Electronic Room Temperature Sensor General Instructions TSMN-90xxx Series TSMN-57011-850-0-01 TSMN-58011-000-0-01 TSMN-81011-000-0-01 Electronic Room Temperature Sensor General Instructions Application The Electronic Room Temperature Sensor is a resistance-temperature

More information

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators

MAx-305 & MAx-318 Series MAx-405 Through MAx-419 Series Two-Position Actuators MAx-305 & MAx-38 Series MAx-405 Through MAx-49 Series Two-Position Actuators General Instructions Application For two-position operation of dampers, valves, and other equipment which require the return

More information

VB-9323 Series. Application. Features. Applicable Literature. 2-1/2" to 6" 125 Lb. Flanged Three-Way Diverting Valves General Instructions

VB-9323 Series. Application. Features. Applicable Literature. 2-1/2 to 6 125 Lb. Flanged Three-Way Diverting Valves General Instructions TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com VB-9323 Series 2-1/2" to 6" 125 Lb. Flanged Three-Way Diverting Valves General Instructions Application VB-9323 series three-way

More information

AV-497. Application. Features. Valve Linkage for MK-6811 and MK-6911 General Instructions

AV-497. Application. Features. Valve Linkage for MK-6811 and MK-6911 General Instructions AV-497 Valve Linkage for MK-6811 and MK-6911 General Instructions Application The AV-497 valve linkage kit is used to field assemble MK-6811 actuators onto 2-1/2 to 5 VB-8xxx series valves and MK-6911

More information

Powers Controls TT 184 Temperature Transmitters

Powers Controls TT 184 Temperature Transmitters Powers Controls Document No. 155-077P25 TT 184-1 Room Transmitter Remote Bulb Average Bulb Rigid Bulb Description The are direct acting, one-pipe instruments that sense temperature and transmit a proportional

More information

Square/Rect. and Square Louvered Face and Plaque Face Diffuser

Square/Rect. and Square Louvered Face and Plaque Face Diffuser /Rect. and Louvered Face and Plaque Face Diffuser Series J: Easily Adjustable from Horizontal to Vertical Vertical Discharge Application: Carnes steel (SK) and aluminum (SE) louvered face diffusers are

More information

TAC PNEUMODULAR. Parts & Accessories Data Sheet PANELS. TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL

TAC PNEUMODULAR. Parts & Accessories Data Sheet PANELS. TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL TAC PNEUMODULAR TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com Parts & Accessories Data Sheet The TAC Pneumodular Control System is designed to ease the assembly and installation

More information

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions

CP-9301 CP Application. Features. Applicable Literature. Electronic Actuator Drives General Instructions CP-90 CP-90 Electronic Drives General Instructions Application The CP-90 and CP-90 electronic actuator drives process a variable input signal from a controller to provide proportional control of an electric

More information

TC-200 Series. Application. Features. Applicable Literature. Single Bulb Thermostats General Instructions

TC-200 Series. Application. Features. Applicable Literature. Single Bulb Thermostats General Instructions T-200 Series Single ulb Thermostats General Instructions Application These units are used for on-off control of media temperature in ducts, tanks, etc. Features Mechanism enclosed in rugged die cast case

More information

VB-8000 Series VB-9313 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents. Valve and Actuator Selection Procedure

VB-8000 Series VB-9313 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents. Valve and Actuator Selection Procedure Selection Guide VB-8000 Series VB-9313 Series Schneider ElectricVB-8000 Series and VB-9000 Series 2-1/2 to 6 Globe Valves with Schneider Electric NSR Forta M800A and M1500A Actuators Applications Schneider

More information

Auxiliary Equipment. Table of Contents. Auxiliary Equipment H-1. Product Product Code Technical Instructions Page #

Auxiliary Equipment. Table of Contents. Auxiliary Equipment H-1.   Product Product Code Technical Instructions Page # Table of Contents Product Product Code Technical Instructions Page # Pneumatic Air Station Equipment 201/656/908 155-005/049/086/137P25 H-3 Pressure Gauges GA142AP 155-025P25 H-7 External Restrictors 184

More information

MS Application. Features. Proportional Valve Actuator General Instructions

MS Application. Features. Proportional Valve Actuator General Instructions Proportional Valve Actuator Application The Proportional Valve Actuator is a non-spring return actuator used with proportional to 10 Vdc or 4 to 0 ma controllers and standard 1/" to 1-1/4" two-way and

More information

SECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes:

SECTION HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY. A. Section Includes: SECTION 15970 HVAC CONTROL SYSTEM PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Thermostats, temperature transmitters, controllers, automatic valves, dampers, damper operators, pneumatic/ electric

More information

POWERS TM CONTROLS LC Pneumatic Damper Actuator

POWERS TM CONTROLS LC Pneumatic Damper Actuator POWERS TM CONTROLS Document No. 155-030P25 AP 331-4 Description Features The LC Actuator is a piston type pneumatic actuator. Air pressure is supplied to both sides of the piston to provide a force balance

More information

MP-5200 Series. Application. Features. Applicable Literature. Electronic Hydraulic Actuator General Instructions

MP-5200 Series. Application. Features. Applicable Literature. Electronic Hydraulic Actuator General Instructions TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com MP-5200 Series Electronic Hydraulic Actuator General Instructions Application The MP-5200 Series actuators are for the electronic

More information

MC-351, 421, 431, MC-4311

MC-351, 421, 431, MC-4311 MC-35, 42, 43, MC-43 Three-Wire, Two Position Actuators General Instructions Applications For two-position operation of dampers or valves in heating, ventilating and air-conditioning systems and similar

More information

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions CP-80-xxx Series to 5 Vdc Input Electronic General Instructions Application The CP-80-xxx Series electronic actuator drive is designed to process a variable to 5 Vdc signal from a controller to provide

More information

MF4E MF4E

MF4E MF4E MF4E-60830-100 TAC DuraDrive Non-Spring Return Floating Actuator General Instructions Application The 35 lb-in. (4 N-m) and MF4E-60830-100 70 lb-in. (8 N-m) non-spring return, direct-coupled actuators

More information

Distributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE RESOURCE DOCUMENTS PAGE #

Distributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE RESOURCE DOCUMENTS PAGE # PRODUCT PRODUCT CODE RESOURCE DOCUMENTS PAGE # Pneumatic Receiver-Controllers Single Input Receiver-Controller RC 195 155-119P25 C-3 Multiple Input Receiver-Controller RC 195 155-036P25 C-5 Pneumatic Transmitters

More information

CP CP

CP CP Electronic Drive General Instructions Application Electronic actuat drive is used to provide proptional control of an electric gear train actuat from a variable voltage DC signal from a controller. Features

More information

AM-751, AM-752, AM-753, AM-754, AM-755. Applications. Applicable Literature

AM-751, AM-752, AM-753, AM-754, AM-755. Applications. Applicable Literature AM-751, AM-752, AM-753, AM-754, AM-755 For Schneider Electric DuraDrive 150 in-lb Spring Return and 300 in-lb Non-Spring Actuators General Instructions Applications The AM-751 and AM-752 anti-rotation

More information

Powers TM Controls Three-way Electro-pneumatic (EP) Valve Model 2

Powers TM Controls Three-way Electro-pneumatic (EP) Valve Model 2 Powers TM Controls Three-way Electro-pneumatic (EP) Valve Model 2 Document No. 155-078P25 VE 265-2 Description The VE 265 Electro-Pneumatic Valve is a general purpose, electrically operated, twoposition

More information

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY SECTION 230533 - PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Static pressure

More information

MANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved.

MANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved. MANUAL INSTALLATION Active Chilled Beam Linear ACBL Series v11 Issue Date: 4/1/18 218 Price Industries Limited. All rights reserved. TABLE OF CONTENTS Product Overview Before You Start...1 Maintenance...1

More information

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S PERFORATED FACE DIFFUSERS P SERIES P SERIES PERFORATED FACE DIFFUSERS P SERIES QUALITY AND EFFICIENCY WITHOUT COMPROMISE Application:

More information

TAC TM Butterfly Valve Assemblies

TAC TM Butterfly Valve Assemblies TAC TM Butterfly Valve Assemblies Technical Data TAC s new butterfly valve line offers a wide range of two- and three-way sizes, along with low pressure pneumatic spring return, electric non-spring return,

More information

POWERS CONTROL RC 195 Multiple Input Receiver- Controller

POWERS CONTROL RC 195 Multiple Input Receiver- Controller POWERS CONTROL RC 195 Multiple Input Receiver- Controller Document No. 155-036P25 RC 195-1 Description Features Application The RC 195 Multiple lnput Receiver-Controller is a pneumatic instrument which

More information

CP (Vdc) CP (Milliamp) CP (Slidewire)

CP (Vdc) CP (Milliamp) CP (Slidewire) CP-91-456 (Vdc) CP-91-716 (Milliamp) CP-91-717 (Slidewire) Electronic General Instructions Application Electronic actuator drive is used to provide proportional control of an electric gear train actuator

More information

AV-608 Linkage Adapter Kit

AV-608 Linkage Adapter Kit TAC 1354 Clifford Avenue P. O. Box 2940 Loves Park, IL 61132-2940 www.tac.com AV-608 Linkage Adapter Kit Adapter for AV-607 TAC DuraDrive Linkage, MX-6XXXX Jackscrew Style Actuators, and VB-9XXX 1-1/2"

More information

LINEAR DIFFUSERS AND BAR GRILLES

LINEAR DIFFUSERS AND BAR GRILLES LINEAR DIFFUSERS AND AR GRILLES LINEAR DIFFUSERS AND AR GRILLES LINEAR SLOT DIFFUSER PLENUMS FOR TECHZONE TYPE CEILINGS Model Series 5300TZ Plenums are designed to fit the 5000TZ Series Slot Diffusers.

More information

Installation Instructions

Installation Instructions Installation Instructions Speedcook Oven Read carefully. Keep these Instructions. INSTALLATION INSTRUCTIONS Electrical Requirements Product rating is 240/208 volts AC, 60 Hertz, 30 amps and 6.5 kilowatts.

More information

Introduction to Johnson Controls Dampers

Introduction to Johnson Controls Dampers Damper and Actuator Product Guide 268.1 Damper Engineering Section Product Bulletin Issue Date 1297 Introduction to Johnson Controls Dampers For over 100 years, Johnson Controls has been the industry leader

More information

453X Series. Application. Features. Two-Position Damper Actuator General Instructions

453X Series. Application. Features. Two-Position Damper Actuator General Instructions 453X Series Two-Position Damper Actuator General Instructions Application The 453L, light duty damper actuators are designed for a variety of two-position, spring return, damper applications. The 453L

More information

POWERS Controls No. 4 Pneumatic Damper Actuator

POWERS Controls No. 4 Pneumatic Damper Actuator POWERS Controls No. 4 Pneumatic Damper Actuator Technical Instructions Document No. 155-032P25 AP 331-2 Actuator Assembly 331-2929 Typical Actuator Assembly 331-2904 Typical Actuator Assembly 331-3000

More information

SECTION METERS AND GAGES FOR PLUMBING PIPING

SECTION METERS AND GAGES FOR PLUMBING PIPING PART 1 GENERAL 1.01 SECTION INCLUDES A. Positive displacement meters. B. Flow meters. SECTION 22 0519 METERS AND GAGES FOR C. Pressure gages and pressure gage taps. D. Thermometers and thermometer wells.

More information

HORD INSTALLATION & SERVICE MANUAL. Hospital Operating Room Diffusers INSTALLATION & SERVICE MANUAL. Date: 06 / 12 Reference # : E-10 1

HORD INSTALLATION & SERVICE MANUAL. Hospital Operating Room Diffusers INSTALLATION & SERVICE MANUAL. Date: 06 / 12 Reference # : E-10 1 HORD Hospital Operating Room Diffusers Date: 06 / 12 Reference # : E-10 1 2 Table of Contents Prior to Installation... 4 Ductwork Layout... 4 Installation of HORD Air Curtain System...5-9 T-Bar Ceiling...5-6

More information

POWERS Controls. Technical Instructions Document No P25 AP December 3, No. 6 Pneumatic Damper Actuator.

POWERS Controls. Technical Instructions Document No P25 AP December 3, No. 6 Pneumatic Damper Actuator. POWERS Controls No. 6 Pneumatic Damper Actuator Technical Instructions AP 331-3 331-2793 Actuator 331-2857 Actuator with Clevis and Pin 331-3012 Extended Shaft and Frame Mounting Description The POWERS

More information

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products

SECURITY PRODUCTS GENERAL PRODUCT OVERVIEW. Security Products GENERAL PRODUCT OVERVIEW Security Products Nailor offers a complete line of Security Grilles, Registers and Diffusers. The product line includes grilles and registers for maximum, medium and minimum security

More information

VB-9213 Series. Application. Features. Applicable Literature

VB-9213 Series. Application. Features. Applicable Literature VB-9213 Series 2-1/2" and 3" Screwed NPT 2-1/2" to 6" 125 Lb. Flanged Stem Down to Close Two-Way Valves General Instructions pplication VB-9213 series single seat, stem down to close, twoway valves control

More information

PNEUMATIC CONTROL SYSTEMS DESIGN AND CONSTRUCTION STANDARD PART 1 - GENERAL. A. Codes and Standards that are Standard at the University:

PNEUMATIC CONTROL SYSTEMS DESIGN AND CONSTRUCTION STANDARD PART 1 - GENERAL. A. Codes and Standards that are Standard at the University: PART 1 - GENERAL 1.01 Purpose: A. This design guideline contained here in includes the requirements for pneumatic control systems at The University of Texas at Austin. It is the intent to provide the highest

More information

EVP SERIES PROPORTIONAL CONTROL VALVES

EVP SERIES PROPORTIONAL CONTROL VALVES EVP SERIES PROPORTIONAL CONTROL VALVES 207 Clippard is pleased to add the EVP series proportional control valve to our electronic product line. This product combines the features of the existing EV series

More information

MODEL 8630-CRC-S, 8630-CRC-P PRESSURA CLEAN ROOM PRESSURE CONTROLLER

MODEL 8630-CRC-S, 8630-CRC-P PRESSURA CLEAN ROOM PRESSURE CONTROLLER MODEL 8630-CRC-S, 8630-CRC-P PRESSURA CLEAN ROOM PRESSURE CONTROLLER INSTALLATION INSTRUCTIONS WARNING: The Model 8630-CRC Clean Room Pressure Controller must be wired to 24 VAC only. Wiring the unit to

More information

makes sure products are delivered Products are offered in steel,

makes sure products are delivered Products are offered in steel, Residential Construction Features Residential Registers, Grilles & Diffusers No one satisfies the demands for For example: an electro-deposition air distribution solutions better than paint creates a flawless

More information

T500 Series. Applications. Features. Applicable Literature. Non-Digital, On/Off Thermostat General Instructions

T500 Series. Applications. Features. Applicable Literature. Non-Digital, On/Off Thermostat General Instructions T500 Series Non-Digital, On/Off Thermostat General Instructions Applications The T500 series thermostats are available in four basic models for low and line voltage control of valves, relays, and fan motors

More information

INDEX. Chapter3. air master. Linear Bar Grilles

INDEX. Chapter3. air master. Linear Bar Grilles Chapter3 INDEX A Linear bar grilles: 1. Supply linear bar grille...: ASLG...3.1 2. Supply linear bar register...: ASLR...3.2 3. Return linear bar grille...: ARLG...3.3 4. Return linear bar register...:

More information

ACCESSORY HOOD DODGE RAM. Call Out Description Parts Quantity 1 Hood Supplied in kit 1 2 Bezel Supplied in kit 2 3 Foam tape supplied in kit 1

ACCESSORY HOOD DODGE RAM. Call Out Description Parts Quantity 1 Hood Supplied in kit 1 2 Bezel Supplied in kit 2 3 Foam tape supplied in kit 1 ACCESSORY HOOD 1 DODGE RAM Call Out Description Parts Quantity 1 Hood Supplied in kit 1 2 Bezel Supplied in kit 2 3 Foam tape supplied in kit 1 2 PROCEDURE STEPS: 1. Disconnect the washer fluid hose (1)

More information

AV-401. Application. Features. Applicable Literature. Pneumatic Actuator Valve Linkage Kit General Instructions

AV-401. Application. Features. Applicable Literature. Pneumatic Actuator Valve Linkage Kit General Instructions AV-401 Pneumatic Actuator Linkage Kit General Instructions Application The AV-401 valve linkage kit is used to field assemble MK-4600 series pneumatic actuators to a variety of 1/2" through 2" valve bodies.

More information

AV-611. Application. Applicable Literature. Schneider Electric DuraDrive Globe Valve Linkage General Instructions

AV-611. Application. Applicable Literature. Schneider Electric DuraDrive Globe Valve Linkage General Instructions AV-611 Schneider Electric DuraDrive Globe Valve Linkage General Instructions Application The AV-611 linkage is designed to link the Schneider Electric DuraDrive Mx41-6xx3 non-spring return and Mx40-704x

More information

Guide Specification SECTION HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY

Guide Specification SECTION HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY SECTION 23 21 16 - HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Pressure gages. 2. Pressure gage taps. 3. Thermometers. 4. Thermometer supports. 5. Test plugs. 6. Air

More information

READ THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-LP SERIES. TMI, LLC Managing Environments

READ THIS FIRST. Read and Save These Instructions AIR CURTAINS INSTALLATION INSTRUCTIONS S-LP SERIES. TMI, LLC Managing Environments READ THIS FIRST Carefully examine the crate(s) for damage before opening. If the carton is damaged, immediately notify shipping company. If the unit(s) were shipped on wooden skids, remove protective wood

More information

VB-9313 Series. Application. Features. Applicable Literature

VB-9313 Series. Application. Features. Applicable Literature V-9313 Series 2-1/2" and 3" Screwed NPT 2-1/2" to 6" 125 Lb. Flanged Three-Way Mixing s General Instructions pplication V-9313 series three-way mixing valves control hot or chilled water in heating or

More information

Distributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE #

Distributed By: M&M Control Service, Inc PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE # Switches Selector Switches SW 786 155-118P25 G-3 Positioning Switch SW 141 155-117P25 G-5 Enthalpy Control Switch EE 141 155-054P25 G-7 Static Pressure

More information

COMMERCIAL HYDRONIC PRODUCTS A MESTEK COMPANY. Convectors STEAM AND HOT WATER RADIATION CC-14

COMMERCIAL HYDRONIC PRODUCTS A MESTEK COMPANY. Convectors STEAM AND HOT WATER RADIATION CC-14 COMMERCIAL HYDRONIC PRODUCTS A MESTEK COMPANY Convectors STEAM AND HOT WATER RADIATION CC-1 Sterling Convectors are engineered for both forced hot water and two-pipe steam heating system installation with

More information

Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element

Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element Product Specifications Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element PSS 1-5A1 A MODEL 2761 MODEL 2781 The Foxboro Dew Point Measurement

More information

CENTRAL VACUUM SYSTEMS

CENTRAL VACUUM SYSTEMS CENTRAL VACUUM SYSTEMS INSTALLATION INSTRUCTIONS Review this manual before installing the central vacuum system Dynovac Industries 1 800 226 1221 1 403 346 4877 #1, 6841 52 Avenue Red Deer, Alberta T4N

More information

A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less.

A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less. SECTION 221513 - COMPRESSED-AIR PIPING PART 1 - GENERAL 1.1 SUMMARY A. This Section includes piping and related specialties for general-service compressed-air systems operating at 150 psig or less. 1.2

More information

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes:

Optima EXHAUST GRILL AND AIR LOUVER. Perforated Ceiling Diffusers. Features: Standard square sizes: Perforated Ceiling Diffusers OPTIMA ceiling diffuser with perforated face, are recoended for heating, ventilating and cooling in centralized air conditioning systems. Perforated face diffusers, with 4-3-

More information

Part No. PAFULAxxx. Figure 2

Part No. PAFULAxxx. Figure 2 Part No. PAFULAxxx - Exhaust Vent -To be installed prior to siding- Remove the trim ring and collar from the vent assembly. Place tape or sealant between the Exhaust Vent and house. Align the tube with

More information

Concealite Life Safety Products Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions

Concealite Life Safety Products Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions Important Safeguards When using electrical equipment, basic safety precautions should always be followed: Read and

More information

Powers Controls RL 147 Positioning Relay

Powers Controls RL 147 Positioning Relay Powers Controls Technical Instructions Document No. 155-038P25 RL 147-2 Description Features Rapid response Product Numbers See Table 1. The is a compact, pneumatic device designed to provide positive

More information

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER INSTALLATION INSTRUCTIONS WARNING: The Model 8682 Adaptive Offset Controller must be wired to 24 VAC only. Wiring the unit to 110 VAC will cause serious unit

More information

Installation Instructions

Installation Instructions Installation Instructions Over The Range Microwave Oven BEFORE YOU BEGIN (Read these instructions completely and carefully.) IMPORTANT IMPORTANT Save these instructions for local inspector s use. Observe

More information

Plaster In Grilles 1/1.5/B/1. AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser

Plaster In Grilles 1/1.5/B/1. AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser 1/1.5/B/1 Plaster In Grilles AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser TROX UK Ltd Caxton Way Thetford Norfolk IP24 3SQ Telephone +44 (0) 1842

More information

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS CONTACT INFORMATION Wolf Customer Service: 800-332-9513 Website: wolfappliance.com As you follow these instructions, you will notice WARNING and

More information

series Linear grilles

series Linear grilles series 30 Linear grilles www.koolair.com Series 30 1 CONTENTS Linear grilles 2 Linear floor grilles 3 Quick selection table 4 Example of selection 5 General dimensions 7 Accessories and mounting 10 General

More information

TAC DuraDrive Product Guide Direct Coupled Actuators

TAC DuraDrive Product Guide Direct Coupled Actuators TAC DuraDrive Product Guide Direct Coupled Actuators SPRING RETURN TAC DuraDrive Spring-Return Direct Coupled Actuators TAC OFFERS A COMPLETE LINE OF DIRECT COUPLED ACTUATORS FOR ALL YOUR SPRING RETURN

More information

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features

VA, VF, and VS Series Direct Mounted Globe Valve Assemblies. Application. Features TAC 1354 Clifford Avenue P.O. Box 2940 Loves Park, Illinois 61132-2940 www.invensysibs.com Two-Way and Three-Way Globe Valve Assemblies with 220 lbf Linear (979 N) Spring Return DuraDrive Actuators Submittal

More information

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise LINEAR BAR GRILLES T SERIES Quality and e!ciency without compromise Weltech Business Centre - Ridgeway - Welwyn Garden City - Hertfordshire AL7 2AA Tel: 01707 871526 - Fax: 01707 871 527 - email sales@jprservices.co.uk

More information

A11 Series Low Temperature Cutout Control

A11 Series Low Temperature Cutout Control A11 Series Low Temperature Cutout Control Installation Instructions Part No. 997-358, Rev. F Issued March 2016 Applications IMPORTANT: All Series A11 temperature controls are designed for use only as operating

More information

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless W Track Recessed 120V Flangeless WT4-RTL, WT8-RTL, WT12-RTL SAFETY INSTRUCTION Read all of these instructions before installing the track system. Turn off power at main switch before installing or modifying

More information

INDEX. Chapter1 0. air master. Round Ceiling Diffusers

INDEX. Chapter1 0. air master. Round Ceiling Diffusers air master Chapter1 0 INDEX A. Round ceiling diffusers 1. Fixed round ceiling diffuser...: ARDF...10.1 2. Round ceiling diffuser with adjustable pattern...: ARD...10.2 Standard sizes...10.3 Air pattern...10.3

More information

CHEVROLET CORVETTE

CHEVROLET CORVETTE Suggested Installation Instructions for: 658-133 and 658-134 1968-1976 Air Conditioning Retro-Fit System 1968-76 CHEVROLET CORVETTE CONTROL & OPERATING INSTRUCTIONS The controls on your new Perfect Fit

More information

A91 Series Thermistor Temperature Sensors For Duct, Immersion and Space Sensing

A91 Series Thermistor Temperature Sensors For Duct, Immersion and Space Sensing A91 Series Thermistor Temperature Sensors For Duct, Immersion and Space Sensing Installation Sheets Manual 121 Temperature Controls Section A Technical Bulletin A91 Issue Date 0179 Application These thermistor

More information

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR BAR GRILLES T SERIES T SERIES C O L M A N Air Distribution E N G I N E E R E D A I R P R O D U C T S LINEAR BAR GRILLES T SERIES

More information

SECTION DUCTWORK ACCESSORIES

SECTION DUCTWORK ACCESSORIES SECTION 15910 DUCTWORK ACCESSORIES PART 1- GENERAL SCOPE This sections includes accessories used in the installation of duct systems. Included are the following topics: PART 1- GENERAL Related Work Reference

More information

CRITICAL ENVIRONMENT DIFFUSERS

CRITICAL ENVIRONMENT DIFFUSERS READ COMPLETELY AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE CRITICAL ENVIRONMENT DIFFUSERS SSLF, SSLFHFD, FRD, FRD-HEPA, HRDP, HRDP- HEPA, SSHEMI, SSHEMI-HEPA INSTALLATION AND SERVICE MANUAL THESE

More information

Flare Valves 1/2 inch 2-Way and 3-Way

Flare Valves 1/2 inch 2-Way and 3-Way Valve and Actuator Manual 977 Valve Product Information Section Product Bulletin VTF Series Issue Date 0596 Flare Valves 1/2 inch 2-Way and 3-Way The 1/2 inch flared valve line is designed to accurately

More information

Total comfort control

Total comfort control Total comfort control YORK ACTIVE CHILLED BEAM WITH PERFORATED RETURN DIFFUSER Table of contents Concept & Technology Air Distribution & Facade Orientation Product Features Dimensions Performance Data

More information

Powers TM Controls VP 656 Powermite Three-way Mixing Valves (Flared Type)

Powers TM Controls VP 656 Powermite Three-way Mixing Valves (Flared Type) VP 656-3 Powers TM Controls VP 656 Powermite Three-way Mixing Valves (Flared Type) Description The VP 656 Powermite Three-way Mixing Valves are designed for water mixing applications. The valve body is

More information

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTION INSTALLATION INSTRUCTION 0 F LOW AMBIENT ACCESSORY MODELS 2LA04703425, 3546 & 3658 (208, 230, 460 & 575 VOLT APPLICATIONS) Supersedes: 530.18-N5.6V (1091) 530.18-N5.6V (1193) FOR 15, 20 & 25 TON COOLING

More information

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES.

EX C E L L E N C E ISO 9001 CERTIFIED COMPANY LINEAR BAR GRILLES. 25 YEARS OF EX C E L L E N C E ISO 9001 CERTIFIED COMPANY 3.0 INDEX ISO 9001 CERTIFIED COMPANY SECTION TOPIC PAGE 3.1 Double deflection linear bar grille ASLG 3 3.2 Double deflection linear bar register

More information

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1 filter ILL. 3. Screw ICP INSTALLATION INSTRUCTIONS for (NPECOMZR006A00) ICP's economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions completely and carefully

More information

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Screw. (Note 4) Spacer for 1 filter ILL. 3. Screw MicroMetl INSTALLATION INSTRUCTIONS for 0637-0311 (CPECOMZR006A00) MicroMetl's 0637 economizer is convertible-it will work in either a down discharge or horizontal discharge application. Read these instructions

More information

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1969 CHEVROLET CAMARO/ FIREBIRD NOTE: INSTRUCTIONS DEPICT CAMARO

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1969 CHEVROLET CAMARO/ FIREBIRD NOTE: INSTRUCTIONS DEPICT CAMARO specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1969 CHEVROLET CAMARO/ FIREBIRD NOTE: INSTRUCTIONS DEPICT CAMARO CONTROL & OPERATING

More information

Pneumatic Controls. Pneumatic Controls Sections

Pneumatic Controls. Pneumatic Controls Sections Pneumatic Controls Pneumatic Controls Sections Controllers and Switches Thermostats Relays Sensors and Transmitters See the Contents Section at the front of the Product Catalog for the complete data sheet

More information

Installation Instructions Vanishing Lid Bracket

Installation Instructions Vanishing Lid Bracket -800-447-88 www.coverpools.com Installation Instructions Vanishing Lid WARNING FOR YOUR SAFETY This product must be installed and serviced by a contractor who is licensed and qualified in pool equipment

More information

PROJ. NO SECTION HYDRONIC PUMPS

PROJ. NO SECTION HYDRONIC PUMPS SECTION 23 21 23 HYDRONIC PUMPS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information