Direct Flow Air Cleaners DF600 Series

Size: px
Start display at page:

Download "Direct Flow Air Cleaners DF600 Series"

Transcription

1 5 Air Filtration

2 Why an Air Filtration System is So Important Air Cleaner Housings How to Select an Air Cleaner Air Cleaner Selection Charts Air Filtration Application Guidelines Direct Flow Air Cleaners DF6 Series AH DF9 Series AH AH AH AH AH AH DF12 Series AH AH AH How to Service a Direct Flow System Frequently Asked Questions OptiAir Air Cleaners OptiAir 4 Series Straight Outlet Outlet OptiAir 5 Series Straight Outlet Outlet OptiAir 6 Series Straight Outlet Outlet OptiAir 8 Series Straight Outlet Outlet OptiAir 1 Series Straight Outlet OptiAir 11 Series Straight Outlet OptiAir 13 Series Straight Outlet Straight Inlet How to Service an OptiAir System Metal Air Cleaners Selection Service Parts Style Style Style AH AH AH AH AH1961 AH AH1963 AH AH1965 AH AH AH1927 AH AH1969 AH AH19271 AH AH AH1973 AH AH1975 AH AH AH AH AH Disposable Air Cleaners Throw-Away Style ECB Style ECC Style ECD Style ECO II ECO-SE Air Intake Components Hump Hoses/Hump Hose Reducers Weather Hoods Mounting Brackets Hose Clamps Dust Ejection Valves Elbows Reducing Elbows Reducer Inlet Sleeves Restriction Indicators Pre-Cleaners Why Use a Pre-Cleaner? Visibowl Fleetguard Accessories Service and Maintenance Tips Cleaning Air Filters Glossary of Terms

3 Why an Air Filtration System is So Important There Is Something In the Air Air is not only vital for any life form on earth but also important for today s state of the art diesel engines. An average Heavy Duty Diesel truck engine requires between 3,65 to 5,6 gallons (13, to 2, liters) of air to burn just one liter of fuel. However, this air is polluted with all kinds of contaminants, such as fumes, dust, smog and other particles. Like temperature and humidity, these particles are not always visible to the eye, but they are harmful to the engine. They diminish the purity of the air and can lead to severe damage of all engine components. Under normal highway conditions, the air consumed by a 16 liter engine contains almost 2 kilograms of dirt/contaminants per 62,5 miles (1, kilometers). Don t Compromise On Air Filtration There is no room for compromise. The air intake is an open loop system, and the air filter only has one opportunity to filter the contaminant out of the intake air. Air filters are essential for heavy duty diesel engines, and the air that these engines breathe needs to be as clean as possible. Poor air quality will significantly impact the performance of a diesel engine. Plugged air filters reduce engine performance, create higher fuel consumption, increase exhaust fumes and are harmful to the environment. Fleetguard air filters are engineered to deliver optimized air quality and provide the best overall performance and service life. To properly perform its function of reducing wear and extending engine life, the air filter must filter 1% of the pre-combustion air and remove as much contaminant of any and every particle size as it can to a very high final efficiency. Sooner or later, the choice of the right filter for the right application can make a substantial difference in wear rate, cost and performance of your diesel engine. From Pre-Cleaning to Direct Flow With a range of over 1,5 different air filtration products from clamps to air housings to state-of-the-art air filters, Fleetguard Heavy Duty Air Filtration, covers all the needs for your sophisticated air intake systems. Fleetguard Visibowl Pre-Cleaners and highly efficient Fleetguard pre-cleaner self cleaning Pre-cleaners are strongly recommended for construction, mining, farming, forestry and other segments where operating conditions are severe. For best preventive maintenance practice and to automatically monitor the performance of your air filter, use Fleetguard Restriction indicators. Fleetguard products are engineered to provide the best overall performance and service life. They are the ideal solution in terms of better engine protection, extended service intervals and lower maintenance cost. Our media technology is designed to meet technical specifications including fiber size, shape, pore size, paper thickness and mechanical strength. Fleetguard LIPS (Lenticular Integral Pleat Spacing) ensures that pleats are evenly spaced and that the air spreads equally throughout the surface to maximize filter capacity and life. Special resins impregnated in the media provide maximum performance. Hot melt bonding ensures proper alignment and protection of pleats throughout filter life. Engine Life cumminsfiltration.com 5-3

4 Air Cleaner Housings Fleetguard air housings, air cleaners and intake components meet the needs of over 2 Original Equipment Manufacturers (OEM). Fleetguard leads the way in air filtration technology through state-of-the-art design and manufacturing capabilities worldwide. We have the experience and technical expertise to design air filtration systems that exceed application requirements and maximize system potential. Fleetguard manufacturing facilities around the world produce air filtration systems and are QS 9, ISO 91 and/or TS16949 certified. All performance data displayed in this section is based on ISO 511/SAE J726 standards. Fleetguard products are used in a wide variety of markets, including: n On-Highway - Heavy and Medium Duty Trucks n Construction and Mining n Agriculture n Marine n Industrial 5-4 cumminsfiltration.com

5 How to Select an Air Cleaner Determine the Requirements n Establish the air flow required - Refer to engine data sheet or contact engine manufacturer - Calculate from the available engine data using the formula below n Establish the maximum allowable initial restriction - Refer to engine data sheet or contact engine manufacturer - If no information is available, use the 152 mm H 2, 1.5 kpa, or 6 in H 2 rule of thumb as a guide for On-Highway applications and 254 mm H 2 O, 2.5 kpa, or 1 in H 2 O for Off-Highway/Industrial applications Determine the Class of Air Cleaner: If in doubt always over-specify n In what type of application/ environment will it operate? - Light dust concentration environment (single stage air cleaner) On highway, Marine, Light dust environments - Medium dust concentration environment (2 stage air cleaner) On/off highway, industrial with moderate dust - Heavy dust concentration environment (2 stage air cleaner with safety element) Off road, industrial equipment with heavy dust in the air Select an Appropriate Air Cleaner n Examine the flow versus restriction curves to determine the restriction at your given flow rate n Check the dimensional data to ensure it will fit the customer's application n Verify that the capacity meets the performance requirements n Inlet and outlet size and positioning Determine the Accessories Needed n Mounting Bracket(s) n Weather Hood n Restriction Indicator n Fleetguard Pre-Cleaner n Rubber Elbows, Hump Hoses, Hose Clamps, etc. Air Flow Calculation Formula Metric: Air flow in m 3 /min = 1 engine displacement in liters; 2 maximum engine RPM; 3 Volumetric Efficiency; 4 Pulsation factor Imperial: Air flow in CFM = swept volume 1 (liters) x speed 2 x VE 3 x PF 4 1 x CF swept volume 5 (CID) x speed 2 x VE 3 x PF x CF 5 engine displacement in cubic inches; 2 maximum engine RPM; 3 Volumetric Efficiency; 4 Pulsation factor Volumetric Efficiency (VE) - VE = can be greater than >2 for very new engine designs - VE = 1.3 to 1.8 for 4 stroke engine with turbocharger - VE =.85 for 4 stroke engine that is naturally aspirated - VE = 1.4 for 2 stroke (cycle) engine with Roots-Compressor (blower) - VE = 1.9 for 2 stroke (cycle) engine with Turbocharger Cycle Factor (CF) - CF = 2 for a four stroke (cycle) engine - CF = 1 for a 2 stroke (cycle) engine Pulsation Factor (PF) - only applies to engines that are both naturally aspirated and having 3 cylinders or less - PF = if only 1 cylinder - PF = for two cylinders - PF = 1.33 for three cylinders cumminsfiltration.com 5-5

6 Air Cleaner Selection Charts OptiAir Air Cleaner Selection Chart AH19334 AH Series AH19481 AH Series AH1926 AH1949 AH19479 AH19261 AH Series AH Series AH19483 AH19487 AH19482 AH19486 AH19474 AH19485 AH19496 AH19484 AH19476 AH AH19477 Series AH Series 5 Series Step 1 - Determine intake flow rate for application. (Directly from engine manufacturer or Cummins catalog.) Step 2 - Find flow rate on the horizontal axis and draw a vertical line to see which air cleaners fit the flow rate. Step 3 - Consider alternatives based on where the flow intersect a given air cleaner. Minimum Flow Rate 2 in H 2 O Restriction NO SAFETY ELEMENT NO SAFETY ELEMENT WITH SAFETY ELEMENT WITH SAFETY ELEMENT Maximum Flow Rate 12 in H 2 O Restriction Flow Rate (CFM) Metal Air Cleaner Selection Chart AH1977 AH1927 AH197 AH19269 AH1965 AH19268 AH1966 AH1963 AH1964 AH1961 AH1962 AH1911 AH1919 AH1918 AH1917 AH1978 AH19271 AH19272 AH1969 AH19259 AH198 AH1979 AH1973 AH1974 Step 1 - Determine intake flow rate for application. (Directly from engine manufacturer or Cummins catalog.) Step 2 - Find flow rate on the horizontal axis and draw a vertical line to see which air cleaners fit the flow rate. Step 3 - Consider alternatives based on where the flow intersect a given air cleaner. Minimum Flow Rate 2 in H 2 O Restriction NO SAFETY ELEMENT WITH SAFETY ELEMENT NO SAFETY ELEMENT WITH SAFETY ELEMENT AH1975 AH1976 Maximum Flow Rate 12 in H 2 O Restriction Flow Rate (CFM) 5-6 cumminsfiltration.com

7 Air Cleaner Selection Charts Direct Flow Flow Air Cleaner Selection Chart Inlet Transition Only Pre-Cleaner Only Inlet Transition and Pre-Cleaner Step 1 - Determine intake flow rate for application. (Directly from engine manufacturer or Cummins Catalog). Step 2 - Find flow rate on the horizontal axis and draw a vertical line to see which air cleaners fit the flow rate. Step 3 - Consider alternatives based on where the flow intersects a given air cleaner. DF6 DF12 DF9 Minimum Flow Rate 2 H O Restriction 2 Maximum Flow Rate 12 H O Restriction Flow Rate (CFM) cumminsfiltration.com 5-7

8 Air Filtration Application Guidelines This section describes Air Filtration Application Guidelines as they relate to Engine Manufacturer Requirements, Environmental Considerations, and Durability. Engine Manufacturer Requirements System Restriction Every engine manufacturer has their own recommendation for the maximum allowable initial (clean) restriction for the air intake system, which includes upstream and downstream ducting and grills. If the system's initial restriction requirements are unknown, use 3.74 kpa (15 in H 2 O) for off- highway applications and 2.49 kpa (1 in H 2 O) for on-highway applications. This application is where ducting specifications are important. Pressure loss through the combination of upstream and downstream ducting is generally kpa (3-5 in H 2 O). However, poor ducting designs can more than double that effect. Proper duct design and care taken to minimize initial restriction will improve the air cleaner's capacity and increase service life. The following are key items for minimizing pressure drop: Ensure that air intake openings are as large as possible. Utilize ideal openings or grills (where possible) to straighten the flow path at air intake openings. Minimize the number of turns and transitions and avoid sharp angles and rough surfaces. Keep the duct diameter as large as possible throughout the system and reduce down as close to the engine/turbo intake as possible. When combining two flows, use gradual Y angles. A gradual Y angle is preferred, as T style connections cause pressure loss due to turbulence. Ducting Designs Ideal Design 3 Marginal Design 9 Negative Design One way to describe dust holding capacity is by taking a ratio of the grams of dust processed by the air cleaner per engine airflow (g/cfm). The following dust holding capacities are recommended for the given dust environments: Dust Holding Capacity 3 25 Dust Holding Capacity Recommendations Dust Environments and Typical Applications Heavy = Construction, mining, convoys on dirt roads, agricultural equipment g/cfm Medium = Asphalt equipment, forklifts Light = On-highway vehicles in developed countries, lawn & turf equipment Extra Light = Marine use, residential stationary equipment 5 For light environments the dust holding capacity can range from g/cfm. Heavy Medium Light Dust Conditions Extra Light Heavy and medium dust environments require a two-stage air cleaner such as an integral pre-cleaner with a tangential inlet, or a spinner fin. Dump trucks and on-road trucks spending more than 2% of their time off-road or in developing countries should anticipate medium or heavy dust conditions. Heavy-duty applications should always utilize an air cleaner with a secondary element. The use of a secondary element is also recommended for medium-duty applications. 5-8 cumminsfiltration.com

9 Air Filtration Application Guidelines Environmental Considerations The purpose of the air intake system is to provide clean, cool, quiet, and dry air for the engine. Keep the following environmental conditions in mind when positioning the air cleaner and intake ducting: Protect the intake air from water ingestion by utilizing weather hoods or other protection. Position the air intake to minimize dust ingression. Do not draw air from the wheel well or under carriage areas. The air intake should be positioned as high as possible and toward the front of the vehicle for on-highway vehicles. (Small variations in the air intake position can greatly improve service life.) Air intake ducting should draw air from near-ambient locations. Increased air intake temperatures have a significant effect on engine power. Continuous Operating Temperature Range (COTR) for the plastic air cleaners shown in this catalog is -4 F (-4 C) to 18 F (82 C). Heat shielding and air baffles are acceptable options for reducing skin temperatures. If higher temperature materials are required, contact your Fleetguard sales representative to inquire about custom designs (minimum quantities may apply). Durability Air cleaners should be chassis mounted to minimize vibration. Engine mounting is only recommended with proper validation by a vehicle/equipment designer. Avoid the mounting of air cleaners or other components to 3-cylinder engines, as the vibration level is excessive due to the natural unbalanced condition of the engine. If vibration is a concern, consider iso-mounting or bracket designs to reduce acceleration levels and move the air cleaner resonance points away from the engine or vehicle resonance frequencies. Consider both the engine and vehicle resonance points. Engine resonance frequencies can be easily calculated. Vehicle resonance points are not easy to calculate. However, many on-highway vehicles have their first resonance point at or around 2 Hz. For further assistance in dealing with vibration issues, contact your Fleetguard representative to inquire about custom designs or materials (minimum quantities may apply). When air cleaners are chassis mounted, pay close attention to the clean side ducting design. Because of the relative movement between the air cleaner and the engine, the ducting will be exposed to additional forces and the hose design may need to compensate for significant length changes between connections during operation. Flexible hose connections are essential. Minimize vibration with a chassis mount. Protect the inlet from harmful elements with a weather hood. Ensure that the design accounts for full relative motion between the air cleaner and the engine. Flexible connections are mandatory. Avoid mounting in areas where ducting is exposed to components that could cause abrasive wear. Miscellaneous Guidelines Torque Range: The torque range for plastic inlet/outlet tubes = 25-4 in-lbs ( N m). Do not over-torque connections. Hose Connections: Use appropriate hose connections. SAE HD Worm Gear F-style or T-bolt are recommended. Connection Points: Minimize the connection points. Leakage is a greater risk with multiple connections. Hose Materials: Utilize the appropriate high temperature material at the turbo. Intake Routing: Use caution when routing intake system ducting by avoiding damage from abrasion and heat sources. Excessive Weight: Avoid excessive unsupported weight on clamped joints (< 3 lb (1.4 kg) recommended). Restriction Indicators: Utilize restriction indicators in the system to monitor restriction and maximize performance and service life. cumminsfiltration.com 5-9

10 Notes 5-1 cumminsfiltration.com

11 Reduced Volume - Improved Performance - Flexible Packaging The patented Direct Flow technology provides the flexibility to optimize the air system performance to size ratio, meeting the demands of today s engines and specialized applications. The Direct Flow Advantage Front Inlet/Front Service Air Out Side Inlet/Front Service Air In Air Out Integrated Handle Improved serviceability Element Label Can display service part information and service instructions Air In Service Element Metal-Free Service Element Direct Flow design utilizes more media volume in less space than some cylindrical systems Phenolic Media Water resistant with high stiffness to improve service intervals Direct Flow Air Cleaners cumminsfiltration.com 5-11

12 DF6 Series AH55555 Direct Flow Air Cleaners Filter Service (Front) Outlet (Rear) Inlet (Front) Specifications Specification Length, Overall Width, Overall Height, Overall Flow, Min. (2" restriction) Flow, Max. (12" restriction) Secondary Element Housing Material Pre-cleaner Integral Inlet Transition AH " (254.3 mm) 25.3" (642.6 mm) 22.29" (566.2 mm) 195 CFM (5.52 m 3 /min) 544 CFM (15.41 m 3 /min) Yes Glass-Filled Polyamide Yes No Specifications subject to change without notice cumminsfiltration.com

13 Direct Flow Air Cleaners DF6 Series AH55555 Ordering Information Air Cleaners Accessories Service Parts AH55555 Direct Flow DF6P -with Integral Pre-Cleaner -Front Inlet S 4" Band Clamp S 5" Band Clamp S 4" Hump Hose S 5" Hump Hose S 4" 9 Elbow S 5" 9 Elbow S 5" to 4" Hump Hose Reducer S Restriction Indicator AF555 AF5538 SP14 Primary Element Secondary Element Service Kit: DEV Tube, DEV Cap, J-Clips (4) Dimensions 1.1 (254.3) Cover Width 9.25 (235.) Allowance for Element Removal 5.5 (139.7) (289.8) (492.3) (454.9) (566.2) (317.) 9. (228.6) 12.6 (33.) 9. (228.6) 18. (457.2) 5. (127.) 4.35 (11.5) All dimensions are in inches (millimeters) 1.5 (3.81) Tube M1 x Places 1/8" NPT Filtered Pressure Tap (546.6) 25.3 (642.6) 5.73 (145.5) 5. (127.) Performance System Restriction vs Flow Rate Restriction (inch H 2 O) AH Restriction (kpa) Restriction Flow Rate in H 2 O kpa CFM m 3 /min cumminsfiltration.com 5-13

14 DF9 Series AH55556 Direct Flow Air Cleaners Outlet (Rear) Filter Service (Front) Inlet (Long Side) Specifications Specification Length, Overall Width, Overall Height, Overall Flow, Min. (2" restriction) Flow, Max. (12 restriction) Secondary Element Housing Material Pre-cleaner Integral Inlet Transition AH " (322.3 mm) 24.54" (623.3 mm) 17.67" (448.8 mm) 234 CFM (6.63 m 3 /min) 652 CFM (18.46 m 3 /min) Yes Glass-Filled Polyamide No Yes Specifications subject to change without notice cumminsfiltration.com

15 Direct Flow Air Cleaners DF9 Series AH55556 Ordering Information AH55556 AF5514 AF5538 SP12 SP14 Air Cleaners Service Parts Direct Flow DF9T -with Inlet Transition -Long Side Inlet Primary Element Secondary Element Service Door Service Kit: DEV Tube, DEV Cap, J-Clips (4) Accessories S 4" Band Clamp S 5" Band Clamp S 4" Hump Hose S 5" Hump Hose S 4" 9 Elbow S 5" 9 Elbow S 5" to 4" Hump Hose Reducer S Weather Hood S Restriction Indicator *AP849 *AP8421 *AP844 *AP841 * Based on Flow Rate Accessories Fleetguard External Pre- Cleaner (Flow= CFM) Fleetguard External Pre- Cleaner (Flow=35-5 CFM) Fleetguard External Pre- Cleaner (Flow=5-65 CFM) Fleetguard External Pre- Cleaner (Flow=65-8 CFM) Dimensions (322.3) 14.6 (357.) Allowance for Element Removal (448.8) M6 x 1. 8 Places * Based on Flow Rate 1.62 (41.1) 5. (127.) All dimensions are in inches (millimeters) 15.5 (393.7) INLET 7.75 (196.9) (623.3) (42.1) 5. (127.) OUTLET 5. (127.) 1/8" NPT Filtered Pressure Tap 9. (228.6) 4.5 (114.3) 1. (254.) (293.1) Performance System Restriction vs Flow Rate Restriction (inch H 2 O) AH Restriction (kpa) Restriction Flow Rate in H 2 O kpa CFM m 3 /min cumminsfiltration.com 5-15

16 DF9 Series AH55557 Direct Flow Air Cleaners Outlet (Rear) Filter Service (Front) Inlet (Long Side) Specifications Specification Length, Overall Width, Overall Height, Overall Flow, Min. (2" restriction) Flow, Max. (12 restriction) Secondary Element Housing Material Pre-cleaner Integral Inlet Transition AH " (33.7 mm) 24.54" (623.3 mm) 21.59" (548.4 mm) 2 cfm (5.66 m 3 /min) 541 cfm (15.32 m 3 /min) Yes Glass-Filled Polyamide Yes No Specifications subject to change without notice cumminsfiltration.com

17 Direct Flow Air Cleaners DF9 Series AH55557 Ordering Information Air Cleaners Accessories Service Parts AH55557 Direct Flow DF9P -with Integral Pre-Cleaner -Long Side Inlet S 4" Band Clamp S 5" Band Clamp S 4" Hump Hose S 5" Hump Hose S 4" 9 Elbow S 5" 9 Elbow S 5" to 4" Hump Hose Reducer S Restriction Indicator AF5514 AF5538 SP12 SP14 Primary Element Secondary Element Service Door Service Kit: DEV Tube, DEV Cap, J-Clips (4) Dimensions 13.2 (33.7) 14.6 (357.) Allowance for Element Removal (623.3) 1. (254.) (293.1) (548.4) M6 x 1. 8 Places 1.62 (41.1) 8.88 (225.6) 12.6 (32.) 9.24 (234.7) All dimensions are in inches (millimeters) (317.) 1.5 (38.1) Tube 15.5 (393.7) 7.75 (196.9) 5.73 (145.5) 1/8" NPT Filtered Pressure Tap (42.1) INLET 5. (127.) 5. (127.) OUTLET 9. (228.6) 4.5 (114.3) Performance System Restriction vs Flow Rate Restriction (inch H 2 O) AH Restriction (kpa) Restriction Flow Rate in H 2 O kpa CFM m 3 /min cumminsfiltration.com 5-17

18 DF9 Series AH55558 Direct Flow Air Cleaners Outlet (Rear) Filter Service (Front) Inlet (Long Side) Specifications Specification Length, Overall Width, Overall Height, Overall Flow, Min. (2" restriction) Flow, Max. (12 restriction) Secondary Element Housing Material Pre-cleaner Integral Inlet Transition AH " (448.8 mm) 24.54" (623.3 mm) 21.59" (548.4 mm) 193 CFM (5.47 m 3 /min) 526 CFM (14.89 m 3 /min) Yes Glass-Filled Polyamide Yes Yes Specifications subject to change without notice cumminsfiltration.com

19 Direct Flow Air Cleaners DF9 Series AH55558 Ordering Information Air Cleaners Accessories Service Parts AH55558 Direct Flow DF9C -with Inlet Transition -with Integral Pre-Cleaner -Long side inlet S 4" Band Clamp S 5" Band Clamp S 4" Hump Hose S 5" Hump Hose S 4" 9 Elbow S 5" 9 Elbow S 5" to 4" Hump Hose Reducer S Restriction Indicator AF5514 AF5538 SP12 SP14 Primary Element Secondary Element Service Door Service Kit: DEV Tube, DEV Cap, J-Clips (4) Dimensions (448.8) 14.6 (357.) Allowance for Element Removal M6 x 1. 8 Places (623.3) 1. (254.) (293.1) 1.62 (41.1) (548.4) 12.6 (32.) 8.88 (225.6) 9.24 (234.7) All dimensions are in inches (millimeters) 1.5 (38.1) Tube (393.7) INLET (127.) 7.75 (196.9) 1/8" NPT Filtered Pressure Tap (42.1) OUTLET 5. (127.) 5. (127.) 9. (228.6) 4.5 (114.3) Performance System Restriction vs Flow Rate Restriction (inch H 2 O) AH Restriction (kpa) Restriction Flow Rate in H 2 O kpa CFM m 3 /min cumminsfiltration.com 5-19

20 DF9 Series AH55559 Direct Flow Air Cleaners Outlet (Rear) Filter Service (Front) Inlet (Short Side) Specifications Specification Length, Overall Width, Overall Height, Overall Flow, Min. (2" restriction) Flow, Max. (12 restriction) Secondary Element Housing Material Pre-cleaner Integral Inlet Transition AH " (56.8 mm) 24.54" (623.3 mm) 9." (228.6 mm) 225 CFM (6.37 m 3 /min) 62 CFM (17.56 m 3 /min) Yes Glass-Filled Polyamide No Yes Specifications subject to change without notice. 5-2 cumminsfiltration.com

21 Direct Flow Air Cleaners DF9 Series AH55559 Ordering Information AH55559 AF5514 AF5538 SP12 SP14 Air Cleaners Service Parts Direct Flow DF9T -with Inlet Transition -Short Side Inlet Primary Element Secondary Element Service Door Service Kit: DEV tube, DEV Cap, J-Clips (4) Accessories S 4" Band Clamp S 5" Band Clamp S 4" Hump Hose S 5" Hump Hose S 4" 9 Elbow S 5" 9 Elbow S 5" to 4" Hump Hose Reducer S Weather Hood S Restriction Indicator *AP849 *AP8421 *AP844 * Based on Flow Rate Accessories Fleetguard External Pre- Cleaner (Flow= CFM) Fleetguard External Pre- Cleaner (Flow=35-5 CFM) Fleetguard External Pre- Cleaner (Flow=5-65 CFM) Dimensions 22.8 (56.8) (444.) (623.3) INLET 9. (228.6) All dimensions are in inches (millimeters) 5. (127.) 4.5 (114.3) 14.6 (357.) Allowance for Element Removal M6 x 1. 8 Places 15.5 (393.7) 5. (127.) 1/8" NPT Filtered Pressure Tap (336.3) 5. (127.) 7.75 (196.9) 1. (254.) (293.1) OUTLET 1.62 (41.1) 5. (127.) Performance System Restriction vs Flow Rate Restriction (inch H 2 O) AH Restriction (kpa) Restriction Flow Rate in H 2 O kpa CFM m 3 /min cumminsfiltration.com 5-21

22 DF9 Series AH5556 Direct Flow Air Cleaners Outlet (Rear) Filter Service (Front) Inlet (Short Side) Specifications Specification Length, Overall Width, Overall Height, Overall Flow, Min. (2" restriction) Flow, Max. (12 restriction) Secondary Element Housing Material Pre-cleaner Integral Inlet Transition AH " (569.2 mm) 24.54" (623.3 mm) 14.84" (376.9 mm) 191 CFM (5.41 m 3 /min) 524 CFM (14.84 m 3 /min) Yes Glass-Filled Polyamide Yes No Specifications subject to change without notice cumminsfiltration.com

23 Direct Flow Air Cleaners DF9 Series AH5556 Ordering Information Air Cleaners Accessories Service Parts AH5556 Direct Flow DF9P -with Integral Pre-Cleaner -Short Side Inlet S 4" Band Clamp S 5" Band Clamp S 4" Hump Hose S 5" Hump Hose S 4" 9 Elbow S 5" 9 Elbow S 5" to 4" Hump Hose Reducer S Restriction Indicator AF5514 AF5538 SP12 SP14 Primary Element Secondary Element Service Door Service Kit: DEV Tube, DEV Cap, J-Clips (4) Dimensions (569.2) (623.3) (376.9) (139.7) (234.4) All dimensions are in inches (millimeters) (282.4) (145.5) Cover Height 3.79 (96.3) 14.6 (357.) Allowance for Element Removal M6 x 1. 8 Places 15.5 (393.7) (317.) 1.5 (38.1) Tube (42.1) 4.5 (114.3) 9. (228.6) INLET 1/8" NPT Filtered Pressure Tap (344.7) (127.) OUTLET 7.75 (196.9) 1.62 (41.1) 5. (127.) 1. (254.) (293.1) Performance System Restriction vs Flow Rate Restriction (inch H 2 O) AH Restriction (kpa) Restriction Flow Rate in H 2 O kpa CFM m 3 /min cumminsfiltration.com 5-23

24 DF9 Series AH55561 Direct Flow Air Cleaners Outlet (Rear) Filter Service (Front) Inlet (Short Side) Specifications Specification Length, Overall Width, Overall Height, Overall Flow, Min. (2" restriction) Flow, Max. (12 restriction) Secondary Element Housing Material Pre-cleaner Integral Inlet Transition AH " (687.3 mm) " (623.3 mm) 14.84" (376.9 mm) 183 CFM (5.18 m 3 /min) 494 CFM (13.99 m 3 /min) Yes Glass-Filled Polyamide Yes Yes Specifications subject to change without notice cumminsfiltration.com

25 Direct Flow Air Cleaners DF9 Series AH55561 Ordering Information Air Cleaners Accessories Service Parts AH55561 Direct Flow DF9C -with Inlet Transition -with Integral Pre-Cleaner -Short Side Inlet S 4" Band Clamp S 5" Band Clamp S 4" Hump Hose S 5" Hump Hose S 4" 9 Elbow S 5" 9 Elbow S 5" to 4" Hump Hose Reducer S Weather Hood S Restriction Indicator AF5514 AF5538 SP12 SP14 Primary Element Secondary Element Service Door Service Kit: DEV Tube, DEV Cap, J-Clips (4) Dimensions 27.6 (687.3) (623.3) (376.9) (139.7) (234.4) All dimensions are in inches (millimeters) 1.5 (38.1) Tube 8.4 (213.4) 5. (127.) (42.1) 4.5 (114.3) 9. (228.6) 14.6 (357.) Allowance for Element Removal M6 x 1. 8 Places INLET 1/8" NPT Filtered Pressure Tap (462.8) 5. (127.) 15.5 (393.7) 7.75 (196.9) OUTLET 1.62 (41.1) 5. (127.) 1. (254.) (293.1) Performance System Restriction vs Flow Rate Restriction (inch H 2 O) AH Restriction (kpa) Restriction Flow Rate in H 2 O kpa CFM m 3 /min cumminsfiltration.com 5-25

26 DF12 Series AH55562 Direct Flow Air Cleaners Outlet (Rear) Filter Service (Front) Mounting Feet On All Four Faces Of Air Cleaner Inlet Specifications Specification Length, Overall Width, Overall Height, Overall Flow, Min. (2" restriction) Flow, Max. (12 restriction) Secondary Element Housing Material Pre-cleaner Integral Inlet Transition AH " (468.9 mm) 25." (635. mm) 14.55" (369.6 mm) 294 CFM (8.33 m 3 /min) 797 CFM (22.57 m 3 /min) Yes Metal/Glass-FIlled Polyamide No Yes Specifications subject to change without notice cumminsfiltration.com

27 Direct Flow Air Cleaners DF12 Series AH55562 Ordering Information AH55562 AF5515 AF5539 SP13 Dimensions (468.9) Air Cleaners Service Parts Direct Flow DF12T -with Inlet Transition Primary Element Secondary Element Service Door INLET All dimensions are in inches (millimeters) 5. (127.) (369.6) 14.6 (357.) Allowance for Element Removal 8. (23.2) 4. (11.6) 8.66 (22.) Accessories 25. (635.) (344.7) 1/8" NPT Filtered Pressure Tap (455.2) S 4" Band Clamp S 5" Band Clamp S 6" Band Clamp S 4" Hump Hose S 5" Hump Hose S 6" Hump Hose S 4" 9 Elbow S 5" 9 Elbow S 6" 9 Elbow S 6" to 5" Reducing Elbow S 5" to 4" Hump Hose Reducer S 6" to 5" Hump Hose Reducer S Weather Hood S Restriction Indicator 5. (127.) 1.85 (47.) 6. (152.4) *AP844 *AP8421 *AP844 *AP841 * Based on Flow Rate Accessories Fleetguard External Pre- Cleaner (Flow= CFM) Fleetguard External Pre- Cleaner (Flow=35-5 CFM) Fleetguard External Pre- Cleaner (Flow=5-65 CFM) Fleetguard External Pre- Cleaner (Flow=65-8 CFM) OUTLET (334.5) (184.2) 6.59 (167.4) Performance System Restriction vs Flow Rate Restriction (inch H 2 O) AH Restriction (kpa) Restriction Flow Rate in H 2 O kpa CFM m 3 /min cumminsfiltration.com 5-27

28 DF12 Series AH55563 Direct Flow Air Cleaners Mounting Feet On All Four Faces Of Air Cleaner Outlet (Rear) Filter Service (Front) Inlet Specifications Specification Length, Overall Width, Overall Height, Overall Flow, Min. (2" restriction) Flow, Max. (12 restriction) Secondary Element Housing Material Pre-cleaner Integral Inlet Transition AH " (477. mm) 25." (635. mm) 21.78" (553.2 mm) 266 CFM (7.53 m 3 /min) 737 CFM (2.87 m 3 /min) Yes Metal/Glass-Filled Polyamide Yes No Specifications subject to change without notice cumminsfiltration.com

29 Direct Flow Air Cleaners DF12 Series AH55563 Ordering Information AH55563 Dimensions Air Cleaners Direct Flow DF12P -with Integral Pre-Cleaner (477.) 15. (381.) 14.6 (357.) Allowance for Element Removal Accessories S 4" Band Clamp S 5" Band Clamp S 6" Band Clamp S 4" Hump Hose S 5" Hump Hose S 6" Hump Hose S 4" 9 Elbow S 5" 9 Elbow S 6" 9 Elbow S 6" to 5" Reducing Elbow S 5" to 4" Hump Hose Reducer S 6" to 5" Hump Hose Reducer S Restriction Indicator 8.66 (22.) 25. (635.) (344.7) AF5515 AF5539 SP13 SP14 Service Parts Primary Element Secondary Element Service Door Service Kit: DEV Tube, DEV Cap, J-Clips (4) (533.2) (317.) 8. (23.2) 1.85 (47.) 6. (152.4) (324.9) 1.5 (38.1) Tube All dimensions are in inches (millimeters) 4. (11.6) 5.73 (145.5) 1/8" NPT Filtered Pressure Tap (455.2) INLET 5. (127.) M1 x Places Performance System Restriction vs Flow Rate (334.5) (184.2) OUTLET 6.59 (167.4) Restriction (inch H 2 O) AH Restriction (kpa) Restriction Flow Rate in H 2 O kpa CFM m 3 /min cumminsfiltration.com 5-29

30 DF12 Series AH55564 Direct Flow Air Cleaners Outlet (Rear) Filter Service (Front) Mounting Feet On All Four Faces Of Air Cleaner Inlet Specifications Specification Length, Overall Width, Overall Height, Overall Flow, Min. (2" restriction) Flow, Max. (12 restriction) Secondary Element Housing Material Pre-cleaner Integral Inlet Transition AH " (595.1 mm) 25." (635. mm) 21.78" (553.2 mm) 251 CFM (7.11 m 3 /min) 699 CFM (19.79 m 3 /min) Yes Metal/Glass-Filled Polyamide Yes Yes Specifications subject to change without notice. 5-3 cumminsfiltration.com

31 Direct Flow Air Cleaners DF12 Series AH55564 Ordering Information AH55564 AF5515 AF5539 SP13 SP14 Air Cleaners Direct Flow DF12C -with Inlet Transition -with Integral Pre-Cleaner Service Parts Primary Element Secondary Element Service Door Service Kit: DEV Tube, DEV Cap, J-Clips (4) Accessories S 4" Band Clamp S 5" Band Clamp S 6" Band Clamp S 4" Hump Hose S 5" Hump Hose S 6" Hump Hose S 4" 9 Elbow Accessories S 5" 9 Elbow S 6" 9 Elbow S 6" to 5" Reducing Elbow S 5" to 4" Hump Hose Reducer S 6" to 5" Hump Hose Reducer S Weather Hood S Restriction Indicator Dimensions (595.1) 14.6 (357.) Allowance for Element Removal 8.66 (22.) 25. (635.) (344.7) 1.85 (47.) (533.2) (324.9) 15. (381.) All dimensions are in inches (millimeters) 1.5 (38.1) Tube 5. (127.) 8. (23.2) 4. (11.6) 1/8" NPT Filtered Pressure Tap (455.2) INLET 5. (127.) 6. (152.4) M1 x Places OUTLET (334.5) (184.2) 6.59 (167.4) Performance System Restriction vs Flow Rate Restriction (inch H 2 O) AH Restriction (kpa) Restriction Flow Rate in H 2 O kpa CFM m 3 /min cumminsfiltration.com 5-31

32 How to Service a Direct Flow System Direct Flow Air Cleaners Servicing the Direct Flow Air Cleaners 1. Open the metal latches to remove the service cover. DF6 Element Size DF9 Element Size DF12 Element Size B 1 A B A 2. Remove the primary element.. DF6 Element Size DF9 Element Size DF12 Element Size 2 A A A 3. Remove the secondary element.. DF6 Element Size DF9 Element Size DF12 Element Size 3 B B B 4. Replace the primary and secondary elements in the same order and close the metal latches.. DF6 Element Size DF9 Element Size DF12 Element Size cumminsfiltration.com

33 Direct Flow Air Cleaners Frequently Asked Questions Direct Flow Frequently Asked Questions Why are two types of Direct Flow models available? The Cummins applied models are manufactured with a TBAP (Temperature Barometric Air Pressure) sensor that is tailored for specifics of a Cummins applied engine system. The standard models are manufactured for a broader range of systems. How is Direct Flow different from a traditional cylindrical air cleaner? The Direct Flow filter element utilizes a rectangular V-Block configuration which allows the filter media to be packaged in a smaller volume, improving performance while reducing size. The rectangular design allows the Direct Flow air cleaner to take advantage of the wasted space in the inner diameter of the conventional air cleaner. The benefits of Direct Flow system are an increase in total dust holding capacity and a decrease in size. These features allow for a longer service interval, less maintenance and vehicle down time, a lower cost of ownership, and the ability to mount the air cleaner in location previously unobtainable with a conventional air cleaner. The Direct Flow air cleaner also includes an integrated pre-cleaner and integrated mounting feet. How long will it last? The Direct Flow air cleaner has been designed to package the optimal amount of filter media in the smallest volume, increasing life and service interval. Compared to an equivalent traditional cylindrical air cleaner, the Direct Flow air cleaner will outperform and outlast conventional cylindrical air cleaners. Where can I get replacement Elements? Direct Flow aftermarket replacement filter elements and service parts will be available at hundreds of Cummins Filtration and Fleetguard worldwide retail locations. Visit cumminsfiltration.com for the nearest location. How do I mount this air cleaner? The Direct Flow air cleaners have integrated mounting feet on both the top and bottom sides of the housing which allow for easier and more convenient installations. Additional mounting band clamps are no longer required as compared to the conventional cylindrical air cleaners. The Direct Flow air cleaner can be mounted either vertically or horizontally. What does the sensor do? The sensor is located in the outlet of the air cleaner housing, which provides a consistent location for the sensor while communicating air flow data to the ECM, optimizing engine and system performance. Why is Direct Flow required for Tier 4? The Direct Flow air cleaner has been designed and integrated with the Cummins Engine Business in order to understand and match the engine performance requirements and industrial specifications for the air intake system. The sensor must be mounted at a specific location in the airstream for accurate calculations, therefore, the Direct Flow housing has been specifically designed to minimize variation and achieve optimized system performance. What does a pre-cleaner do? A pre-cleaner is used to remove about 75% of all incoming dust from reaching the filter element. A pre-cleaner uses centrifugal force to move dust particles out of the air stream and then expels these particles back into the environment. What is aspiration? Aspirating the air cleaner increases the efficiency of the precleaner by pulling a small vacuum and extracting the large dust particles from the pre-cleaner. Typically, the efficiency of most pre-cleaners is 75%, an aspirated pre-cleaner is normally 9% efficient. This increase in efficiency increases the life of the filter element about 25%. Aspirating the air cleaner is done by installing an aspirator within the exhaust flow; the aspirator uses a venturi to create a pressure differential which provides the vacuum pressure to the air cleaner. For more information, contact Technical Assistance at FILTER. Can Direct Flow be used for Tier 3 applications? Absolutely. The Direct Flow air cleaner has been designed to operate in any air filtration environment. cumminsfiltration.com 5-33

34 Notes 5-34 cumminsfiltration.com

35 Innovative Design Meets All OEM Requirements Cummins Filtration has revolutionized air filtration design with the introduction of its patented Fleetguard OptiAir technology. OptiAir systems address key design requirements of all equipment manufacturers: Reduction in system size to fit shrinking engine compartments Higher dust holding capacity to extend service intervals Two-stage air housing design to extend filter life Lower system restriction to deliver maximum engine performance Reduced service time to lower maintenance costs Secondary element optional The OptiAir Advantage Outlet Options Systems available in both straight and 9 rotatable designs Two-Stage Air Housing Design Removes large particulates, extending filter life Pressure Tap Easy-to-install filter restriction gauge option Highly Durable Resin Construction Plastic or metal mounting options Optional Secondary Element Design Added engine protection Quick reference Service Label Replacement filter information 2 3 OptiAir Air Cleaners 11 SERIES PRIMARY FILTER AF25962 SECONDARY FILTER AF DOWN Mono Latch Twist Lock Cover with Multi-Locking Positions Installation flexibility, easy to service, reduced maintenance time Dust Ejection Valve Removal of large particulates and moisture Increased Outlet Area Increased area resulting in reduced restriction Highly Resistant Urethane Seal Excellent sealing capacity Increased Filter Media Area Greater capacity - longer filter life cumminsfiltration.com 5-35

36 4 Series Straight Outlet OptiAir Air Cleaners Inlet Twist Lock Cover Outlet Restriction Indicator Port Dust Ejection Valve Specifications Specification AH19474 AH19496 Length Overall 9.3" (237.1 mm) 9.3 (237.1 mm) Cover 5.6 (141.6 mm) 5.6 (141.6 mm) Flow, Min. (2 restriction) 38 CFM (1.1 m 3 /min) 3 CFM (.8 m 3 /min) Flow, Max. (12 restriction) 12 CFM (2.9 m 3 /min) 83 CFM (2.4 m 3 /min) Secondary Element No Yes Housing Material Glass-Filled Polypropylene Glass-Filled Polypropylene Pre-Cleaner Integral Yes Yes Outlet Straight Straight Dust Holding Capacity per Cummins Specification Specification AH19474 AH19496 Allowable Flow for 1 g/cfm < 63 CFM (1.8 m 3 /min) < 57 CFM (1.6 m 3 /min) Allowable Flow for 25 g/cfm < 35 CFM (1. m 3 /min) < 34 CFM (1. m 3 /min) Specifications subject to change without notice cumminsfiltration.com

37 OptiAir Air Cleaners 4 Series Straight Outlet Ordering Information Part Number AH19474 AH19496 Dimensions 1.3 (33.3) Air Cleaners OptiAir 4 Series Air Cleaner without Secondary Element with Straight Outlet OptiAir 4 Series Air Cleaner with Secondary Element with Straight Outlet 2. (5.8) INLET.5 (11.8) Accessories S Mounting Bracket 1 No. of Brackets Required S Outlet Band Clamps S Weather Hood N/A Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator AH19496 AH19474 (not shown) 7.5 (189.3) 1.42 (36) Service Parts AF26116 Primary Element N/A Magnum Primary Element AF2635 Secondary Element S Dust Ejection Valve S Cover Assembly 3.25 (82.6) 2. (5.8) 5.6 (141.6) Cover 3.95 (1.3) 7.1 (18.) Allowance for Element Removal 1.5 (38.1) Tube 5.85 (148.7) OUTLET All dimensions are in inches (millimeters) Performance System Restriction vs Flow Rate Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH19496 AH19496 AH AH Restriction (kpa) Capacity (g) Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (55) 1.98 (1.56) 571 (61) (65) 2.32 (1.84) 42 (465) (74) 2.63 (2.1) 257 (329) (83) 2.89 (2.35) 115 (17) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-37

38 4 Series 9 Outlet OptiAir Air Cleaners Inlet Restriction Indicator Port Twist Lock Cover Outlet Dust Ejection Valve Specifications Specification AH19485 AH19484 Length Overall 1.4" (263.3 mm) 1.4" (263.3 mm) Cover 5.6" (141.6 mm) 5.6" (141.6 mm) Flow, Min. (2" restriction) 35 CFM (1. m 3 /min) 25 CFM (.7 m 3 /min) Flow, Max. (12 restriction) 92 CFM (2.6 m 3 /min) 8 CFM (2.3 m 3 /min) Secondary Element No Yes Housing Material Glass-Filled Polypropylene Glass-Filled Polypropylene Pre-cleaner Integral Yes Yes Outlet 9 Elbow 9 Elbow Dust Holding Capacity per Cummins Specification Specification AH19485 AH19484 Allowable Flow for 1 g/cfm < 57 CFM (1.6 m 3 /min) < 55 CFM (1.6 m 3 /min) Allowable Flow for 25 g/cfm < 32 CFM (.9 m 3 /min) < 31 CFM (.9 m3 /min) Specifications subject to change without notice cumminsfiltration.com

39 OptiAir Air Cleaners 4 Series 9 Outlet Ordering Information Part Number AH19485 AH19484 Dimensions 1.3 (33.3) Air Cleaners OptiAir 4 Series Air Cleaner without Secondary Element with 9 Outlet OptiAir 4 Series Air Cleaner with Secondary Element with 9 Outlet 2. (5.8) INLET.5 (11.8) Accessories S Mounting Bracket 1 No. of Brackets Required S Outlet Band Clamps S Weather Hood N/A Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator AH19484 AH19485 (not shown) 7.5 (189.3) Service Parts AF26116 Primary Element N/A Magnum Primary Element AF2635 Secondary Element S Dust Ejection Valve S Cover Assembly 3.25 (82.6) 5.6 (141.6) Cover 3.95 (1.3) 7.1 (18.) Allowance for Element Removal 1.5 (38.1) Tube 5.85 (148.7) 2. (5.8) All dimensions are in inches (millimeters) 2.6 (66.) OUTLET Performance System Restriction vs Flow Rate Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH AH19484 AH19485 AH Restriction (kpa) Capacity (g) Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (52) 1.81 (1.47) 52 (58) (63) 2.12 (1.78) 364 (45)) (72) 2.38 (2.4) 25 (32)) (8) 2.61 (2.27) 135 (19) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-39

40 5 Series Straight Outlet OptiAir Air Cleaners Inlet Outlet Twist Lock Cover Restriction Indicator Port Dust Ejection Valve Specifications Specification AH19483 AH19482 Length Overall 13.1" (332.3 mm) 13.1" (332.3 mm) Cover 6.5" (166. mm) 6.5" (166. mm) Flow, Min. (2 restriction) 6 CFM (1.7 m 3 /min) 45 CFM (1.3 m 3 /min) Flow, Max. (12 restriction) 163 CFM (4.6 m 3 /min) 12 CFM (3.4 m 3 /min) Secondary Element No Yes Housing Material Glass-Filled Polypropylene Glass-Filled Polypropylene Pre-cleaner Integral Yes Yes Outlet Straight Straight Dust Holding Capacity per Cummins Specification Specification AH19483 AH19482 Allowable Flow for 1 g/cfm < 141 CFM (4. m 3 /min) < 116 CFM (3.3 m 3 /min) Allowable Flow for 25 g/cfm < 85 CFM (2.4 m 3 /min) < 74 CFM (2.1 m 3 /min) Specifications subject to change without notice. 5-4 cumminsfiltration.com

41 OptiAir Air Cleaners 5 Series Straight Outlet Ordering Information Part Number AH19483 AH19482 Dimensions 1.5 (38.1) Air Cleaners OptiAir 5 Series Air Cleaner without Secondary Element with Straight Outlet OptiAir 5 Series Air Cleaner with Secondary Element with Straight Outlet 2.5 (63.5) INLET.4 (9.8) Accessories S Mounting Bracket 1 No. of Brackets Required S Outlet Band Clamps S Weather Hood N/A Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator AH19482 AH19483 (not shown) 11.2 (284.3) 1.5 (38.1) Service Parts AF26168 Primary Element N/A Magnum Primary Element AF26351 Secondary Element S Dust Ejection Valve S Cover Assembly 3.82 (97.) 2.5 (63.5) 4.24 (17.6) OUTLET 6.52 (165.7) Cover 1.71 (272.) Allowance for Element Removal 1.5 (38.1) Tube 8.22 (28.9) All dimensions are in inches (millimeters) Performance System Restriction vs Flow Rate Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH AH AH19483 AH Restriction (kpa) Capacity (g) Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (87) 3.17 (2.46) 1845 (17) (1) 3.74 (2.83) 1585 (1465) (111) 4.16 (3.14) 13 (1285) (12) 4.62 (3.4) 93 (15) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-41

42 5 Series 9 Outlet OptiAir Air Cleaners Inlet Restriction Indicator Port Twist Lock Cover Outlet Dust Ejection Valve Specifications Specification AH19487 AH19486 Length Overall 14.5" (368.3 mm) 14.5" (368.3 mm) Cover 6.5" (166. mm) 6.5" (166. mm) Flow, Min. (2" restriction) 7 CFM (2. m 3 /min) 4 CFM (1.1 m 3 /min) Flow, Max. (12 restriction) 145 CFM (4.1 m 3 /min) 11 CFM (3.1 m 3 /min) Secondary Element No Yes Housing Material Glass-Filled Polypropylene Glass-Filled Polypropylene Pre-cleaner Integral Yes Yes Outlet 9 Elbow 9 Elbow Dust Holding Capacity per Cummins Specification Specification AH19487 AH19486 Allowable Flow for 1 g/cfm < 127 CFM (3.6 m 3 /min) < 15 CFM (3. m 3 /min) Allowable Flow for 25 g/cfm < 85 CFM (2.4 m 3 /min) < 79 CFM (2.2 m 3 /min) Specifications subject to change without notice cumminsfiltration.com

43 OptiAir Air Cleaners 5 Series 9 Outlet Ordering Information Part Number AH19487 AH19486 Dimensions 1.5 (38.1) Air Cleaners OptiAir 5 Series Air Cleaner without Secondary Element with 9 Outlet OptiAir 5 Series Air Cleaner with Secondary Element with 9 Outlet 2.5 (63.5) INLET.4 (9.8) Accessories S Mounting Bracket 1 No. of Brackets Required S Outlet Band Clamps S Weather Hood N/A Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator AH19486 AH19487 (not shown) 14.1 (358.5) Service Parts AF26168 Primary Element N/A Magnum Primary Element AF26351 Secondary Element S Dust Ejection Valve S Cover Assembly 3.82 (97.) 6.52 (165.7) Cover 4.24 (17.6) Performance System Restriction vs Flow Rate 1.71 (272.) Allowance for Element Removal 1.5 (38.1) Tube 8.22 (28.9) All dimensions are in inches (millimeters) 2.5 (63.5) 3.1 (77.7) OUTLET Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH AH Restriction (kpa) Capacity (g) AH AH Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (81) 2.97 (2.29) 1747 (188) (96) 3.37 (2.72) 147 (142) (15) 3.79 (2.97) 113 (14) (11) 4.11 (3.11) 75 (8) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-43

44 6 Series Straight Outlet OptiAir Air Cleaners Inlet Twist Lock Cover Outlet Restriction Indicator Port Dust Ejection Valve Specifications Specification AH19476 AH19477 Length Overall 14.8" (375.1 mm) 14.8" (375.1 mm) Cover 7.6" (193.7 mm) 7.6" (193.7 mm) Flow, Min. (2 restriction) 98 CFM (2.8 m 3 /min) 8 CFM (2.3 m 3 /min) Flow, Max. (12" Restriction) 24 CFM (6.8 m 3 /min) 26 CFM (5.8 m 3 /min) Secondary Element No Yes Housing Material Glass-Filled Polypropylene Glass-Filled Polypropylene Pre-cleaner Integral Yes Yes Outlet Straight Straight Dust Holding Capacity per Cummins Specification Specification AH19476 AH19477 Allowable Flow for 1 g/cfm < 212 CFM (6. m 3 /min) < 191 CFM (5.4 m 3 /min) Allowable Flow for 25 g/cfm < 135 CFM (3.8 m 3 /min) < 126 CFM (3.6 m 3 /min) Specifications subject to change without notice cumminsfiltration.com

45 OptiAir Air Cleaners 6 Series Straight Outlet Ordering Information Part Number AH19476 AH19477 Dimensions 1.8 (45.8) Air Cleaners OptiAir 6 Series Air Cleaner without Secondary Element with Straight Outlet OptiAir 6 Series Air Cleaner with Secondary Element with Straight Outlet 3. (76.2) INLET.4 (9.5) Accessories S Mounting Bracket 1 No. of Brackets Required S Outlet Band Clamps S Weather Hood S Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator AH19477 AH19476 (not shown) 12.9 (327.2) 1.5 (38.1) Service Parts AF26117 Primary Element N/A Magnum Primary Element AF26118 Secondary Element S Dust Ejection Valve S Cover Assembly 4.41 (112.) 3. (76.2) 4.84 (123.) OUTLET 7.63 (193.7) Cover (314.8) Allowance for Element Removal 1.5 (38.1) Tube 9.38 (238.2) All dimensions are in inches (millimeters) Performance System Restriction vs Flow Rate Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH AH Restriction (kpa) Capacity (g) AH AH Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (135) 4.84 (3.82) 293 (324) (16) 5.61 (4.53) 2425 (2578) (18) 6.2 (5.1) 1986 (2184) (22) 6.8 (5.72) 14 (16) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-45

46 6 Series 9 Outlet OptiAir Air Cleaners Inlet Restriction Indicator Port Twist Lock Cover Outlet Dust Ejection Valve Specifications Specification AH19489 AH19488 Length Overall 16.7" (423.3 mm) 16.7" (423.3 mm) Cover 7.6" (193.7 mm) 7.6" (193.7 mm) Flow, Min. (2" restriction) 85 CFM (2.4 m 3 /min) 7 CFM (2. m 3 /min) Flow, Max. (12 restriction) 213 CFM (6. m 3 /min) 175 CFM (5. m 3 /min) Secondary Element No Yes Housing Material Glass-Filled Polypropylene Glass-Filled Polypropylene Pre-cleaner Integral Yes Yes Outlet 9 Elbow 9 Elbow Dust Holding Capacity per Cummins Specification Specification AH19489 AH19488 Allowable Flow for 1 g/cfm < 196 CFM (5.6 m 3 /min) < 175 CFM (5. m 3 /min)* Allowable Flow for 25 g/cfm < 132 CFM (3.7 m 3 /min) < 128 CFM (3.6 m 3 /min) * Flow rate limited by restriction Specifications subject to change without notice cumminsfiltration.com

47 OptiAir Air Cleaners 6 Series 9 Outlet Ordering Information Air Cleaners Accessories Service Parts Part Number AH19489 AH19488 Dimensions OptiAir 6 Series Air Cleaner without Secondary Element with 9 Outlet OptiAir 6 Series Air Cleaner with Secondary Element with 9 Outlet S Mounting Bracket 1 No. of Brackets Required S Outlet Band Clamps S Weather Hood S Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator AF26117 Primary Element N/A Magnum Primary Element AF26118 Secondary Element S Dust Ejection Valve S Cover Assembly 1.8 (45.8) 3. (76.2) INLET.4 (9.5) AH19488 AH19489 (not shown) 16.3 (413.8) 4.41 (112.) 4.84 (123.) 3.44 (87.3) 7.63 (193.7) Cover (314.8) Allowance for Element Removal 1.5 (38.1) Tube 9.38 (238.2) All dimensions are in inches (millimeters) 3. (76.2) OUTLET Performance System Restriction vs Flow Rate Restriction (inch H 2 O) AH AH Restriction (kpa) Typical System Capacity vs Flow Rate Capacity (g) AH AH Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (115) 4.19 (3.26) 3 (34) (138) 4.96 (3.91) 2459 (3) (157) 5.52 (4.45) 1986 (251) (175) 6.3 (4.96) 145 (1925) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-47

48 8 Series Straight Outlet OptiAir Air Cleaners Inlet Twist Lock Cover Outlet Restriction Indicator Port Dust Ejection Valve Specifications Specification AH19261 AH1926 Length Overall 16.2" (411. mm) 16.2" (411. mm) Cover 9.3" (237. mm) 9.3" (237. mm) Flow, Min. (2 restriction) 175 CFM (5. m 3 /min) 13 CFM (2.9 m 3 /min) Flow, Max. (12 restriction) 388 CFM (11. m 3 /min) 29 CFM (8.2 m 3 /min) Secondary Element No Yes Housing Material Glass-Filled Polypropylene Glass-Filled Polypropylene Pre-cleaner Integral Yes Yes Outlet Straight Straight Dust Holding Capacity per Cummins Specification Specification AH19261 AH1926 Allowable Flow for 1 g/cfm < 336 CFM (9.5 m 3 /min) < 285 CFM (8.1 m 3 /min) Allowable Flow for 25 g/cfm < 216 CFM (6.1 m 3 /min) < 26 CFM (5.8 m 3 /min) Specifications subject to change without notice cumminsfiltration.com

49 OptiAir Air Cleaners 8 Series Straight Outlet Ordering Information Part Number AH19261 AH1926 Dimensions 2.22 (56.5) Air Cleaners OptiAir 8 Series Air Cleaner without Secondary Element with Straight Outlet OptiAir 8 Series Air Cleaner with Secondary Element with Straight Outlet 3.75 (95.25) Accessories S Mounting Bracket 1 No. of Brackets Required S Outlet Band Clamps S Weather Hood S Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator AH1926 AH19261 (not shown) (4.8) (368.4) (38.1) INLET Service Parts AF2596 Primary Element N/A Magnum Primary Element AF25961 Secondary Element S Dust Ejection Valve S Cover Assembly 5.4 (137.5) 4. (11.6) 5.4 (138.4) OUTLET 9.33 (237.1) Cover 14. (355.25) Allowance for Element Removal Performance System Restriction vs Flow Rate 1.5 (38.1) Tube 9.66 (245.4) All dimensions are in inches (millimeters) Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH AH Restriction (kpa) Capacity (g) AH AH Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (27) 7.79 (5.86) 4583 (5155) (242) 8.98 (6.85) 3857 (4369) (27) 1.5 (7.65) 2844 (3392) (29) 1.99 (8.21) 212 (26) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-49

50 8 Series 9 Outlet OptiAir Air Cleaners Inlet Restriction Indicator Port Twist Lock Cover Outlet Dust Ejection Valve Specifications Specification AH19491 AH1949 Length Overall 18.6" (472.1 mm) 18.6" (472.1 mm) Cover 9.3" (237. mm) 9.3" (237. mm) Flow, Min. (2" restriction) 13 CFM (3.7 m 3 /min) 1 CFM (2.8 m 3 /min) Flow, Max. (12 restriction) 33 CFM (9.3 m 3 /min) 266 CFM (7.5 m 3 /min) Secondary Element No Yes Housing Material Glass-Filled Polypropylene Glass-Filled Polypropylene Pre-cleaner Integral Yes Yes Outlet 9 Outlet 9 Outlet Dust Holding Capacity per Cummins Specification Specification AH19491 AH1949 Allowable Flow for 1 g/cfm < 321 CFM (9.1 m 3 /min) < 266 CFM (7.5 m 3 /min)* Allowable Flow for 25 g/cfm < 212 CFM (6. m 3 /min) < 191 CFM (5.4 m 3 /min) * Flow rate limited by restriction. Specifications subject to change without notice. 5-5 cumminsfiltration.com

51 OptiAir Air Cleaners 8 Series 9 Outlet Ordering Information Part Number AH19491 AH1949 Dimensions 2.22 (56.5) Air Cleaners OptiAir 8 Series Air Cleaner without Secondary Element with 9 Outlet OptiAir 8 Series Air Cleaner with Secondary Element with 9 Outlet 3.75 (95.25) INLET.2 (4.8) Accessories S Mounting Bracket 1 No. of Brackets Required S Outlet Band Clamps S Weather Hood S Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator AH1949 AH19491 (not shown) 18.4 (467.4) Service Parts AF2596 Primary Element N/A Magnum Primary Element AF25961 Secondary Element S Dust Ejection Valve S Cover Assembly 5.4 (137.5) 5.4 (138.4) 3.5 (88.9) 9.33 (237.1) Cover 14. (355.25) Allowance for Element Removal 1.5 (38.1) Tube 9.66 (245.4) All dimensions are in inches (millimeters) 3.5 (88.9) OUTLET Performance System Restriction vs Flow Rate Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH1949 AH AH19491 AH Restriction (kpa) Capacity (g) Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (19) 6.6 (5.38) 595 (4756) (22) 7.65 (6.23) 4525 (43) (247) 8.5 (7.) 373(364) (266) 9.35 (7.53) 295 (315) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-51

52 1 Series Straight Outlet OptiAir Air Cleaners Inlet Twist Lock Cover Outlet Restriction Indicator Port Dust Ejection Valve Specifications Specification AH19478 AH19479 Length Overall 17.4" (442.6 mm) 17.4" (442.6 mm) Cover 1.7" (272. mm) 1.7" (272. mm) Flow, Min. (2" restriction) 2 CFM (5.7 m 3 /min) 175 CFM (5. m 3 /min) Flow, Max. (12 restriction) 57 CFM (14.4 m 3 /min) 411 CFM (11.6 m 3 /min) Secondary Element No Yes Housing Material Glass-Filled Polypropylene Glass-Filled Polypropylene Pre-cleaner Integral Yes Yes Outlet Straight Straight Dust Holding Capacity per Cummins Specification Specification AH19478 AH19479 Allowable Flow for 1 g/cfm < 489 CFM (13.9 m 3 /min) < 411 CFM (11.6 m 3 /min)* Allowable Flow for 25 g/cfm < 323 CFM (9.1 m 3 /min) < 315 CFM (8.9 m 3 /min) * Flow rate limited by restriction. Specifications subject to change without notice cumminsfiltration.com

53 OptiAir Air Cleaners 1 Series Straight Outlet Ordering Information Air Cleaners Accessories Service Parts Part Number AH19478 AH19479 OptiAir 1 Series Air Cleaner without Secondary Element with Straight Outlet OptiAir 1 Series Air Cleaner with Secondary Element with Straight Outlet S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S Weather Hood S Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator AF2612 Primary Element N/A Magnum Primary Element AF26121 Secondary Element S Dust Ejection Valve S Cover Assembly Dimensions 2.5 (63.5) 4.5 (114.3) INLET.4 (9.7) AH19479 AH19478 (not shown) (394.9) 1.5 (37.9) 6.48 (158.8) 4.5 (114.3) 5.76 (146.4) OUTLET 1.7 (271.8) Cover (314.8) Allowance for Element Removal 1.5 (38.1) Tube 12.3 (312.3) All dimensions are in inches (millimeters) Performance System Restriction vs Flow Rate Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH19479 AH19479 AH AH Restriction (kpa) Capacity (g) Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (289) 1.14 (8.18) 767 (8248) (336) (9.52) 659 (7546) (375) (1.62) 5535 (685) (411) (11.64) 44 (599) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-53

54 11 Series Straight Outlet OptiAir Air Cleaners Inlet Twist Lock Cover Outlet Restriction Indicator Port Dust Ejection Valve Specifications Specification AH19333 AH19334 Length Overall 19.2" (489. mm) 19.2" (489. mm) Cover 12.2" (39.2 mm) 12.2" (39.2 mm) Flow, Min. (2 restriction) 25 CFM (7.1 m 3 /min) 23 CFM (6.5 m 3 /min) Flow, Max. (12 restriction) 663 CFM (18.8 m 3 /min) 544 CFM (15.4 m 3 /min) Secondary Element No Yes Housing Material Glass-Filled Polypropylene Glass-Filled Polypropylene Pre-cleaner Integral Yes Yes Outlet Straight Straight Dust Holding Capacity per Cummins Specification Specification AH19333 AH19334 Allowable Flow for 1 g/cfm < 663 CFM (18.8 m 3 /min)* < 544 CFM (15.4 m 3 /min)* Allowable Flow for 25 g/cfm < 474 CFM (13.4 m 3 /min) < 454 CFM (12.9 m 3 /min) * Flow rate limited by restriction. Specifications subject to change without notice cumminsfiltration.com

55 OptiAir Air Cleaners 11 Series Straight Outlet Ordering Information Part Number AH19333 AH19334 Dimensions 3. (76.2) Air Cleaners OptiAir 11 Series Air Cleaner without Secondary Element with Straight Outlet OptiAir 11 Series Air Cleaner with Secondary Element with Straight Outlet 5. (127.) INLET.22 (5.7) Accessories S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S Weather Hood S Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator AH19334 AH19333 (not shown) (438.9) 1.7 (44.4) Service Parts AF25962 Primary Element N/A Magnum Primary Element AF25963 Secondary Element S Dust Ejection Valve S Cover Assembly 7. (177.8) 6.77 (171.9) OUTLET 5. (127.) (39.2) Cover 16.1 (49.1) Allowance for Element Removal Performance System Restriction vs Flow Rate 1.5 (38.1) Tube (35.2) All dimensions are in inches (millimeters) Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH19334 AH AH19333 AH Restriction (kpa) Capacity (g) Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (39) (11.4) 1223 (123) (451) 15.7 (12.77) 17 (1158) (51) (14.44) 8951 (1162) (544) (15.41) 7 (92) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-55

56 13 Series Straight Outlet OptiAir Air Cleaners Twist Lock Cover Inlet Outlet Restriction Indicator Port Dust Ejection Valve Specifications Specification AH1948 AH19481 Length Overall 23." (583.5 mm) 23." (583.5 mm) Cover 14." (356.2 mm) 14." (356.2 mm) Flow, Min. (2" restriction) 45 CFM (12.7 m 3 /min) 4 CFM (11.3 m 3 /min) Flow, Max. (12 restriction) 1171 CFM (33.2 m 3 /min) 954 CFM (27. m 3 /min) Secondary Element No Yes Housing Material Glass-Filled Polypropylene Glass-Filled Polypropylene Pre-cleaner Integral Yes Yes Outlet Straight Straight Dust Holding Capacity per Cummins Specification Specification AH1948 AH19481 Allowable Flow for 1 g/cfm < 1134 CFM (32.1 m 3 /min) < 954 CFM (27. m 3 /min)* Allowable Flow for 25 g/cfm < 75 CFM (2. m 3 /min) < 673 CFM (19.1 m 3 /min) * Flow rate limited by restriction. Specifications subject to change without notice cumminsfiltration.com

57 OptiAir Air Cleaners 13 Series Straight Outlet Ordering Information Part Number AH1948 AH19481 Dimensions 2.9 (73.) Air Cleaners OptiAir 13 Series Air Cleaner without Secondary Element with Straight Outlet OptiAir 13 Series Air Cleaner with Secondary Element with Straight Outlet 7. (177.8) INLET.17 (4.3) Accessories S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S Weather Hood S Hump-Hose S 9 Elbow S 9 Reducing Elbow S Restriction Indicator AH19481 AH1948 (not shown) 21. (535.) 1.7 (44.4) Service Parts AF26124 Primary Element N/A Magnum Primary Element AF26125 Secondary Element S Dust Ejection Valve S Cover Assembly 8. (22.3) 7. (177.8) 7.85 (199.3) OUTLET 14. (356.2) Cover 16. (46.) Allowance for Element Removal Performance System Restriction vs Flow Rate 1.5 (38.1) Tube 16.5 (418.3) All dimensions are in inches (millimeters) Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH AH Restriction (kpa) Capacity (g) AH AH Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (676) 22.6 (19.14) (16789) (779) (22.6) (1511) (87) (24.64) (1295) (953) (26.99) 1482 (1442) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-57

58 13 Series Straight Inlet OptiAir Air Cleaners Inlet Twist Lock Cover Restriction Indicator Port Outlet Dust Ejection Valve Specifications Specification Length Overall Cover Flow, Min. (2" restriction) Flow, Max. (12 restriction) Secondary Element Housing Material Pre-cleaner Integral Outlet AH " (63.7 mm) 14.1" (358.1 mm) 612 CFM (17.3 m 3 /min) 153 CFM (42.6 m 3 /min) No Plastic No Straight Dust Holding Capacity per Cummins Specification Specification AH19274 Allowable Flow for 3 g/cfm < 1263 CFM (35.8 m 3 /min) Allowable Flow for 1 g/cfm < 682 CFM (19.4 m 3 /min) Allowable Flow for 25 g/cfm < 338 CFM (9.6 m 3 /min) Specifications subject to change without notice cumminsfiltration.com

59 OptiAir Air Cleaners 13 Series Straight Inlet Ordering Information Air Cleaners Accessories Service Parts Part Number AH19274 Dimensions OptiAir 13 Series Air Cleaner without Secondary Element with Straight Outlet S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S Weather Hood S Hump-Hose S 9 Elbow S 9 Reducing Elbow S Restriction Indicator AH19274 AF2578 Primary Element AF2578M Magnum Primary Element S Dust Ejection Valve Q76517 Cover Assembly 8. (23.2) INLET.17 (4.4) 21.1 (535.9) 7.5 (19.5) 3.13 (79.4) 8.3 (29.6) 7. (177.8) 7.85 (199.4) OUTLET 14. (356.2) Cover Performance System Restriction vs Flow Rate 16. (46.) Allowance for Element Removal 1.5 (38.1) Tube Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH Restriction (kpa) Capacity (g) AH Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-59

60 How to Service an OptiAir System OptiAir Air Cleaners 1 Time for an element change... The restriction indicator mounted on your OptiAir system indicates when your OptiAir element needs changing. 2 Lift the lever as indicated on the OptiAir cover label. 3 Twist the OptiAir cover to the left into the open position. 4 Remove the OptiAir cover. 5 Twist the end of the filter to disengage seal. Gently remove the filter element 1 from the housing. Inspect the filter for foreign material on the sealing surface and potential marks of dust on the clean air side. 1 If servicing a system that contains a secondary element that needs to be replaced, apply the same procedure as shown in step cumminsfiltration.com

61 OptiAir Air Cleaners How to Service an OptiAir System 6 Thoroughly clean the sealing surface and the inside of the OptiAir housing. 7 Inspect the new filter element 2 for damage and insert into the housing. 8 Place the OptiAir cover back on the housing. Make sure dust ejection valve is orientated downward. 9 Twist the OptiAir cover to the right into the locked position 1 Reset the restriction indicator. 2 If servicing a system that contains a secondary element that needs to be replaced, apply the same procedure as shown in step 7. cumminsfiltration.com 5-61

62 Notes 5-62 cumminsfiltration.com

63 Selection Metal Air Cleaners Medium Dust Applications Integral Pre-Cleaner Primary Element Only Part Number 1" H 2 O m kpa AH AH AH AH AH AH AH AH AH AH AH AH AH Light Dust Applications Primary Element Only Part Number Part Number 6" H 2 O 1" H 2 O m kpa AH AH AH AH Heavy or Medium Dust Applications Integral Pre-Cleaner Primary and Secondary Element m kpa AH AH AH AH AH AH AH AH AH Metal Air Cleaners cumminsfiltration.com 5-63

64 Service Parts Metal Air Cleaners Style 1 AH1917 AH1918 AH1919 AH1911 AH1961 AH1963 AH1965 AH1969 A B C D E Part O-Ring Wing Nut Element Wing Nut Dust Ejector A F Cover Assembly B D C F E Style 2 AH1962 AH1964 AH1966 AH19268 AH197 A B C D E F G H Part O-Ring Wing Nut Element Wing Nut Dust Ejector Cover Assembly Secondary Element Wing Nut B F A D E C H G Style 3 AH1973 AH19259 Part AH1974 AH1975 AH19269 AH1927 A B C Wing Nut Element Wing Nut AH1976 AH1977 AH19271 AH19272 D E Dust Ejector Secondary Element D C E AH1978 AH1979 A B AH cumminsfiltration.com

65 Notes cumminsfiltration.com 5-65

66 AH1917 Metal Air Cleaners Inlet Cover Outlet Dust Ejection Valve Specifications Specification Length Overall Body Flow, Min. (2" Restriction) Flow, Max. (12" Restriction) Secondary Element Housing Material Pre-cleaner Integral AH " (216. mm) 4.38" (111.3 mm) 31 CFM (.9 m 3 /min) 76 CFM (2.2 m 3 /min) No Metal Yes Dust Holding Capacity per Cummins Specification Specification AH1917 Allowable Flow for 3 g/cfm < 75 CFM (2.1 m 3 /min) Allowable Flow for 1 g/cfm < 58 CFM (1.6 m 3 /min) Allowable Flow for 25 g/cfm < 4 CFM (1.1 m 3 /min) Specifications subject to change without notice cumminsfiltration.com

67 Metal Air Cleaners AH1917 Ordering Information Part Number AH1917 Dimensions 1.75 (44.45) Air Cleaner Metal Air Cleaner 1.3 (33.) Accessories S Mounting Bracket 1 No. of Brackets Required N/A Outlet Band Clamps S Weather Hood N/A N/A N/A N/A 8. (23) Allowance for Element Removal.12 (3.) Hump-Hose 9 Elbow 9 Reducing Elbow Restriction Indicator 2.8 (71.1) 8.5 (216) 4.6 (116.8) 1.5 (38.1) AF1658K N/A N/A Service Parts Primary Element Magnum Primary Element Secondary Element S Dust Ejection Valve S S Wing Nut/Clips S Cover Assembly 1. (25.4) 4.38 (111.3) Body 4.57 (116.1) Cover.25 (6.4) 1.75 (44.45) 5.3 (136) All dimensions are in inches (millimeters) Performance System Restriction vs Flow Rate 1.4 (26.4) 1.5 (38.1) Tube Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH Restriction (kpa) Capacity (g) AH Restriction Flow Rate Typical Capacity in H 2 O kpa CFM m 3 /min grams ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-67

68 AH1918 Metal Air Cleaners Inlet Cover Outlet Dust Ejection Valve Specifications Specification Length Overall Body Flow, Min. (2" Restriction) Flow, Max. (12" Restriction) Secondary Element Housing Material Pre-cleaner Integral AH " (326.4 mm) 5.3" (133.4 mm) 44 CFM (1.3 m 3 /min) 113 CFM (3.2 m 3 /min) No Metal Yes Dust Holding Capacity per Cummins Specification Specification AH1918 Allowable Flow for 1 g/cfm < 96 CFM (2.7 m 3 /min) Allowable Flow for 25 g/cfm < 68 CFM (1.9 m 3 /min) Specifications subject to change without notice cumminsfiltration.com

69 Metal Air Cleaners AH1918 Ordering Information Part Number AH1918 Dimensions 2. (5.8) 1. (25) 1.5 (38.1) Air Cleaner Metal Air Cleaner Accessories S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S Weather Hood N/A Hump-Hose S 9 Elbow N/A N/A 9 Reducing Elbow Restriction Indicator 11. (279) Allowance for Element Removal 3. (326.4) 2. (76.2) 1.5 (38.1) (5.8) INLET AF25543K N/A N/A Service Parts Primary Element Magnum Primary Element Secondary Element S Dust Ejection Valve S S Wing Nut/Clips S Cover Assembly.25 (6.4) 5.25 (133.4) Body OUTLET 2. (5.8) 3.11 (79.) 1.5 (38.1) All dimensions are in inches (millimeters) Performance System Restriction vs Flow Rate 1.25 (31.8) Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH Restriction (kpa) Capacity (g) AH Restriction Flow Rate Typical Capacity in H 2 O kpa CFM m 3 /min grams ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-69

70 AH1919 Metal Air Cleaners Inlet Cover Outlet Dust Ejection Valve Specifications Specification Length Overall Body Flow, Min. (2" Restriction) Flow, Max. (12" Restriction) Secondary Element Housing Material Pre-cleaner Integral AH " (346.7 mm) 6.6" (166.4 mm) 71 CFM (2. m 3 /min) 184 CFM (5.2 m 3 /min) No Metal Yes Dust Holding Capacity per Cummins Specification Specification Allowable Flow for 3 g/cfm Allowable Flow for 1 g/cfm Allowable Flow for 25 g/cfm AH1919 < 18 CFM (5.1 m 3 /min) < 145 CFM (4.1 m 3 /min) < 13 CFM (2.9 m 3 /min) Specifications subject to change without notice. 5-7 cumminsfiltration.com

71 Metal Air Cleaners AH1919 Ordering Information Part Number AH1919 Dimensions 1.34 (34.).84 (21.3) Air Cleaner Metal Air Cleaner 2.5 (63.5) 12. (35) Allowance for Element Removal Accessories S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S Weather Hood N/A N/A N/A N/A 4. (11.6) Hump-Hose 9 Elbow 9 Reducing Elbow Restriction Indicator (346.7) 1.81 (46.) INLET AF437K AF437KM N/A Service Parts Primary Element Magnum Primary Element Secondary Element S Dust Ejection Valve S S Wing Nut/Clips S Cover Assembly 2. (5.8).25 (6.4) 6.55 (166.4) Body OUTLET 2.25 (57.15) 3.9 (78.5) 1.5 (38.1) All dimensions are in inches (millimeters) 1.25 (31.8) Performance System Restriction vs Flow Rate Restriction (inch H 2 O) AH Restriction (kpa) Typical System Capacity vs Flow Rate Capacity (g) AH Restriction Flow Rate Typical Capacity in H 2 O kpa CFM m 3 /min grams ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-71

72 AH1911 Metal Air Cleaners Inlet Cover Outlet Dust Ejection Valve Specifications Specification Length Overall Body Flow, Min. (2" Restriction) Flow, Max. (12" Restriction) Secondary Element Housing Material Pre-cleaner Integral AH " (369.6 mm) 7.9" (2.4 mm) 18 CFM (3.1 m 3 /min) 267 CFM (7.6 m 3 /min) No Metal Yes Dust Holding Capacity per Cummins Specification Specification Allowable Flow for 1 g/cfm Allowable Flow for 25 g/cfm AH1911 < 246 CFM (7. m 3 /min) < 165 CFM (4.7 m 3 /min) Specifications subject to change without notice cumminsfiltration.com

73 Metal Air Cleaners AH1911 Ordering Information Part Number AH1911 Dimensions 1.5 (38.1) 1. (25) Air Cleaner Metal Air Cleaner 3. (76.2) 13. (33) Allowance for Element Removal Accessories S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S Weather Hood S Hump-Hose S 9 Elbow N/A N/A 4. (11.6) 9 Reducing Elbow Restriction Indicator 14.5 (369.6) 2.6 (52.3) INLET AF49K AF49KM N/A Service Parts Primary Element Magnum Primary Element Secondary Element S Dust Ejection Valve S S Wing Nut/Clips S Cover Assembly 2. (5.8).25 (6.4) 7.89 (2.4) Body 3.25 (82.6) 3. (76.2) OUTLET 3. (76.2) All dimensions are in inches (millimeters) Performance System Restriction vs Flow Rate 2. (5.8) Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH Restriction (kpa) Capacity (g) AH Restriction Flow Rate Typical Capacity in H 2 O kpa CFM m 3 /min grams ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-73

74 AH1961 AH1962 Metal Air Cleaners Inlet Cover Outlet Dust Ejection Valve Specifications Specification AH1961 AH1962 Length Overall 16.9" (429. mm) 16.9" (429. mm) Body, Max. 5.3" (2.4 mm) 5.3" (2.4 mm) Flow, Min. (2" Restriction) 58 CFM (1.6 m 3 /min) 48 CFM (1.4 m 3 /min) Flow, Max. (12" Restriction) 147 CFM (4.2 m 3 /min) 125 CFM (35 m 3 /min) Secondary Element No Yes Housing Material Metal Metal Pre-cleaner Integral Yes Yes Dust Holding Capacity per Cummins Specification Specification AH1961 AH1962 Allowable Flow for 1 g/cfm < 123 CFM (3.5 m 3 /min) < 12 CFM (2.9 m 3 /min) Allowable Flow for 25 g/cfm < 85 CFM (2.4 m 3 /min) < 72 CFM (2. m 3 /min) Specifications subject to change without notice cumminsfiltration.com

75 Metal Air Cleaners AH1961 AH1962 Ordering Information Part Number AH1961 AH1962 Dimensions 1.5 (38.1) 5.25 (133.4) Body Air Cleaners Metal Air Cleaner without Secondary Element Metal Air Cleaner with Secondary Element 2.5 (63.5) 1. (25.4) 15. (381.) Allowance for Element Removal Accessories S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S Weather Hood N/A Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator 3. (76.2) 16.9 (429) Ref. INLET AF1823K N/A AF26118 Service Parts Primary Element Magnum Primary Element Secondary Element S Dust Ejection Valve S S Wing Nut/Clips S Cover Assembly 1.75 (44.5) 2. (5.8) 1.44 (36.6) 1/8" NPT Pressure Tap.25 (6.4) 2.5 (63.5) OUTLET 3.12 (79.2) 1.5 (38.1) All dimensions are in inches (millimeters) Performance System Restriction vs Flow Rate 1.25 (31.8) Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH AH Restriction (kpa) Capacity (g) AH AH Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (88) 2.92 (2.49) 1691 (139) (12) 3.37 (2.89) 137 (129) (114) 3.79 (3.23) 969 (699) (125) 4.16 (3.54) 662 (391) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-75

76 AH1963 AH1964 Metal Air Cleaners Inlet Cover Outlet Dust Ejection Valve Specifications Specification AH1963 AH1964 Length Overall 17.7" (448. mm) 17.7" (448. mm) Body, Max. 6.6" (166.4 mm) 6.6" (166.4 mm) Flow, Min. (2" Restriction) 72 CFM (2. m 3 /min) 65 CFM (1.8 m 3 /min) Flow, Max. (12" restriction) 188 CFM (5.3 m 3 /min) 168 CFM (4.8 m 3 /min) Secondary Element No Yes Housing Material Metal Metal Pre-cleaner Integral Yes Yes Dust Holding Capacity per Cummins Specification Specification AH1963 AH1964 Allowable Flow for 1 g/cfm <184 CFM (5.2 m 3 /min) < 159 CFM (4.5 m 3 /min) Allowable Flow for 25 g/cfm < 143 CFM (4. m 3 /min) <123 CFM (3.5 m 3 /min) Specifications subject to change without notice cumminsfiltration.com

77 Metal Air Cleaners AH1963 AH1964 Ordering Information Part Number AH1963 AH1964 Dimensions 1.5 (38) 6.55 (166.4) Body 1. (25.4) Air Cleaners Metal Air Cleaner without Secondary Element Metal Air Cleaner with Secondary Element 3. (76.2) Accessories S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S Weather Hood S Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator 4. (11.6) (448) INLET OUTLET 1.32 (33.5).25 (6.4) 1/8" NPT Pressure Tap 3. (76.2) AF166K AF166KM AF1982 Service Parts Primary Element Magnum Primary Element Secondary Element S Dust Ejection Valve S S Wing Nut/Clips S Cover Assembly 3.11 (79.) Performance System Restriction vs Flow Rate 16. (46) Allowance for Element Removal 1.25 (31.8) 1.5 (38.1) 1.81 (46.) 2. (5.8) All dimensions are in inches (millimeters) Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH AH Restriction (kpa) Capacity (g) AH AH Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (116) 3.62 (3.29) 4159 (3316) (135) 4.25 (3.82) 3258 (2552) (153) 4.81 (4.33) 245 (185) (168) 5.32 (4.76) 171 (1192) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-77

78 AH1965 AH1966 Metal Air Cleaners Inlet Cover Outlet Dust Ejection Valve Specifications Specification AH1965 AH1966 Length Overall 16.1" (458.5 mm) 16.1" (458.5 mm) Body, Max. 7.9" (2.4 mm) 7.9" (2.4 mm) Flow, Min. (2" Restriction) 13 CFM (3.7 m 3 /min) 15 CFM (3. m 3 /min) Flow, Max. (12" Restriction) 331 CFM (9.4 m 3 /min) 28 CFM (7.9 m 3 /min) Secondary Element No Yes Housing Material Metal Metal Pre-cleaner Integral Yes Yes Dust Holding Capacity per Cummins Specification Specification AH1965 AH1966 Allowable Flow for 1 g/cfm < 331 CFM (9.4 m 3 /min)* < 28 CFM (7.9 m 3 /min)* Allowable Flow for 25 g/cfm < 256 CFM (7.3 m 3 /min) < 24 CFM (6.8 m 3 /min) * Flow rate limited by restriction. Specifications subject to change without notice cumminsfiltration.com

79 Metal Air Cleaners AH1965 AH1966 Ordering Information Part Number AH1965 AH1966 Dimensions 1.5 (38) 1. (2.5) Air Cleaners Metal Air Cleaner without Secondary Element Metal Air Cleaner with Secondary Element 3.75 (95.25) Accessories S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S Weather Hood S Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator 15. (381) Allowance for Element Removal 4. (11.6) INLET AF459K N/A AF413 Service Parts Primary Element Magnum Primary Element Secondary Element S Dust Ejection Valve S S Wing Nut/Clips S Cover Assembly 18.5 (458.5) 2.44 (62.) 2.5 (63.5) 1.44 (36.6).25 (6.4) 1/8" NPT Filtered Pressure Tap 7.89 (2.4) Body 8.6 (24.7) Cup 3.5 (88.9) OUTLET 3.25 (82.6) 3. (76.2) All dimensions are in inches (millimeters) Performance System Restriction vs Flow Rate Restriction (inch H 2 O) AH AH Restriction (kpa) 2. (5.8) Typical System Capacity vs Flow Rate Capacity (g) AH AH Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (185) 6.51 (5.24) 6927 (6897) (219) 7.59 (6.2) 6146 (6415) (251) 8.52 (7.11) 532 (5787) (28) 9.37 (7.93) 4412 (542) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-79

80 AH19268 Metal Air Cleaners Inlet Outlet Dust Ejection Valve Specifications Specification Length Overall Body, Max. Flow, Min. (2" Restriction) Flow, Max. (12" Restriction) Secondary Element Housing Material Pre-cleaner Integral AH " (46.7 mm) 7.9" (2.4 mm) 14 CFM (4. m 3 /min) 317 CFM (9. m 3 /min) No Metal Yes Dust Holding Capacity per Cummins Specification Specification Allowable Flow for 1 g/cfm Allowable Flow for 25 g/cfm * Flow rate limited by restriction. AH19268 < 317 CFM (9. m 3 /min)* < 223 CFM (6.3 m 3 /min) Specifications subject to change without notice. 5-8 cumminsfiltration.com

81 Metal Air Cleaners AH19268 Ordering Information Part Number AH19268 Dimensions Air Cleaners Metal Air Cleaner without Secondary Element Accessories S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S Weather Hood S Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator Service Parts AF459K Primary Element N/A Magnum Primary Element AF413 Secondary Element S Dust Ejection Valve S Wing Nut/Clips S Cover Assembly (38.1) (25.4) 3.75 (92.25) 1/8" NPT Filtered Pressure Tap 15. (381.) Allowance for Element Removal 16.1 (46.65) 2.44 (62.) INLET 2.5 (63.5) 1.44 (36.6).25 (6.4) 7.89 (2.4) Body 3.5 (88.9) 7. (177.8) All dimensions are in inches (millimeters) OUTLET Performance System Restriction vs Flow Rate Restriction (inch H 2 O) AH Restriction (kpa) 1.3 (33.2) Typical System Capacity vs Flow Rate Capacity (g) AH Restriction Flow Rate Typical Capacity in H 2 O kpa CFM m 3 /min grams ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-81

82 AH1927 AH19269 Metal Air Cleaners Inlet Outlet Dust Ejection Valve Specifications Specification AH1927 AH19269 Length Overall 2.1" (519.4 mm) 2.1" (519.4 mm) Body, Max. 9." ( mm) 9." (227.3 mm) Flow, Min. (2" Restriction) 18 CFM (5.1 m 3 /min) 15 CFM (4.2 m 3 /min) Flow, Max. (12" Restriction) 46 CFM (13. m 3 /min) 383 CFM (1.9 m 3 /min) Secondary Element No No Housing Material Metal Metal Pre-cleaner Integral Yes Yes Dust Holding Capacity per Cummins Specification Specification AH1927 AH19269 Allowable Flow for 1 g/cfm < 43 CFM (11.4 m 3 /min) < 368 CFM (1.4 m 3 /min) Allowable Flow for 25 g/cfm < 279 CFM (7.9 m 3 /min) < 269 CFM (7.6 m 3 /min) Specifications subject to change without notice cumminsfiltration.com

83 Metal Air Cleaners AH1927 AH19269 Ordering Information Part Number AH1927 AH19269 Dimensions 6.5 (165.1) 7.5 (19.5) Air Cleaners Metal Air Cleaner without Secondary Element Metal Air Cleaner with Secondary Element 9.47 (24.54) Cover 4. (11.6) 2.54 (64.52) 8.95 (227.33) Body 17. (431.8) Allowance for Element Removal Accessories S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S Weather Hood S Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator 2.45 (519.43) 17.4 (441.96) 2.7 (68.58) INLET AF1735K N/A AF415 Service Parts Primary Element Magnum Primary Element Secondary Element S Dust Ejection Valve S S Wing Nut/Clips S Cover Assembly 2.4 (6.96) 1.25 (31.75).25 (6.4) 1/8" NPT Pressure Tap 4. (11.6) OUTLET 1.5 (38.1) 1.25 (31.75) All dimensions are in inches (millimeters) Performance System Restriction vs Flow Rate Restriction (inch H 2 O) AH AH Restriction (kpa) Typical System Capacity vs Flow Rate Capacity (g) AH AH Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (259) 8.55 (7.33) 6924 (651) (34) 1.14 (8.61) 5864 (5245) (345) (9.77) 455 (3812) (383) 13.3 (1.85) 2236 (342) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-83

84 AH1969 AH197 Metal Air Cleaners Inlet Cover Outlet Dust Ejection Valve Specifications Specification AH1969 AH197 Length Overall 18.5" (469.4 mm) 18.5" (469.4 mm) Body, Max. 12.1" (36.6 mm) 12.1" (36.6 mm) Flow, Min. (2" Restriction) 24 CFM (6.8 m 3 /min) 175 CFM (5. m 3 /min) Flow, Max. (12" Restriction) 631 CFM (17.9 m 3 /min) 447 CFM (12.7 m 3 /min) Secondary Element No Yes Housing Material Metal Metal Pre-cleaner Integral Yes Yes Dust Holding Capacity per Cummins Specification Specification AH1969 AH197 Allowable Flow for 3 g/cfm < 615 CFM (17.4 m 3 /min) < 441 CFM (12.5 m 3 /min) Allowable Flow for 1 g/cfm < 495 CFM (14. m 3 /min) < 441 CFM (12.5 m 3 /min) Allowable Flow for 25 g/cfm < 329 CFM (9.3 m 3 /min) < 32 CFM (9.1 m 3 /min) Specifications subject to change without notice cumminsfiltration.com

85 Metal Air Cleaners AH1969 AH197 Ordering Information Part Number AH1969 AH197 Dimensions Air Cleaners Metal Air Cleaner without Secondary Element Metal Air Cleaner with Secondary Element 5. (127.) 3.9 (78.5) Accessories S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S Weather Hood S Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator 5. (127.) (469.4) 5.25 (133.4) INLET AF418 AF418M AF49M Service Parts Primary Element Magnum Primary Element Secondary Element S Dust Ejection Valve S S Wing Nut/Clips S Cover Assembly 3.5 (88.9) 1.75 (44.4) 1/8" - 27 NPT Pressure Tap and Pipe Cap.25 (6.3) 12.7 (36.6) Body 5. (127.) OUTLET 3.5 (88.9) Performance System Restriction vs Flow Rate 13. (33) Allowance for Element Removal 2.2 (55.9) 3. (76.2) All dimensions are in inches (millimeters) Typical System Capacity vs Flow Rate Restriction (inch H 2 O) Restriction (kpa) AH AH197 AH1969 AH Capacity (g) 64 Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (31) (8.78) 6187 (8161) (361) (1.22) 458 (711) (46) (11.5) 2984 (5743) (447) (12.66) 1397 (4171) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-85

86 AH19271 AH19272 Metal Air Cleaners Inlet Outlet Dust Ejection Valve Specifications Specification AH19271 AH19272 Length Overall 21.9" (556.3 mm) 21.9" (556.3 mm) Body, Max. 11." (279.7 mm) 11." (279.7 mm) Flow, Min. (2" Restriction) 4 CFM (11.3 m 3 /min) 27 CFM (7.7 m 3 /min) Flow, Max. (12" Restriction) 767 CFM (21.7 m 3 /min) 686 CFM (19.4 m 3 /min) Secondary Element No Yes Housing Material Metal Metal Pre-cleaner Integral Yes Yes Dust Holding Capacity per Cummins Specification Specification AH19271 AH19272 Allowable Flow for 1 g/cfm < 674 CFM (19.1 m 3 /min) < 653 CFM (18.5 m 3 /min) Allowable Flow for 25 g/cfm < 445 CFM (12.6 m 3 /min) < 41 CFM (11.4 m 3 /min) Specifications subject to change without notice cumminsfiltration.com

87 Metal Air Cleaners AH19271 AH19272 Ordering Information Part Number AH19271 AH19272 Dimensions (318.77) 2.94 (74.67) Air Cleaners Metal Air Cleaner without Secondary Element Metal Air Cleaner with Secondary Element 17.5 (444.5) Allowance for Element Removal Accessories S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S Weather Hood S Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator 21.9 (556.26) (468.37) 6. (152.4) INLET 3.5 (88.9) 1.59 (4.38) AF4754 N/A AF4755 Service Parts Primary Element Magnum Primary Element Secondary Element S Dust Ejection Valve S S Wing Nut/Clips S Cover Assembly 8.77 (222.75) 9.7 (246.38) 11.1 (279.65) Body.25 (6.3) 1/8" - 27 NPT Pressure Tap 5. (127.) OUTLET 2.2 (55.88) 3. (76.2) All dimensions are in inches (millimeters) Performance System Restriction vs Flow Rate 2.2 (55.9) Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH AH Restriction (kpa) Capacity (g) AH19272 AH Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (48) 15.7 (13.59) 1442 (9294) (557) (15.77) 8749 (8263) (625) 19.6 (17.7) 636 (71) (686) (19.43) 233 (5844) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-87

88 AH19259 Metal Air Cleaners Inlet Outlet Dust Ejection Valve Specifications Specification Length Overall Body Flow, Min. (2" Restriction) Flow, Max. (12" Restriction) Secondary Element Housing Material Pre-cleaner Integral AH " (636.3 mm) 14.1" (358.1 mm) 355 CFM (1.1 m 3 /min) 897 CFM (25.4 m 3 /min) Yes Metal Yes Dust Holding Capacity per Cummins Specification Specification Allowable Flow for 1 g/cfm Allowable Flow for 25 g/cfm * Flow rate limited by restriction. AH19259 < 897 CFM (25.4 m 3 /min)* < 841 CFM (23.8 m 3 /min) Specifications subject to change without notice cumminsfiltration.com

89 Metal Air Cleaners AH19259 Ordering Information Part Number AH19259 Dimensions 6. (152.4) Air Cleaner Metal Air Cleaner 4.5 (12.9) 2. (58) Allowance for Element Removal Accessories S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S S Weather Hood S Hump-Hose S 9 Elbow S S 9 Reducing Elbow S Restriction Indicator 25.5 (636.3) 22.5 (56.1) 3.75 (95.3) INLET 3. (76.2) Service Parts AF1828 Primary Element N/A Magnum Primary Element AF1894M Secondary Element S Dust Ejection Valve S Wing Nut/Clips N/A Cover Assembly 1. (254.) 2. (5.8).25 (6.35) 14.1 (358.1) Body 6. (152.4) 1.5 (267) OUTLET 3. (76.2) All dimensions are in inches (millimeters) Performance System Restriction vs Flow Rate Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH Restriction (kpa) Capacity (g) AH Restriction Flow Rate Typical Capacity in H 2 O kpa CFM m 3 /min grams ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-89

90 AH1973 AH1974 Metal Air Cleaners Inlet Outlet Dust Ejection Valve Specifications Specification AH1973 AH1974 Length Overall 24.6" (625.9 mm) 24.6" (625.9 mm) Body, Max. 16.1" (48.9 mm) 16.1" (48.9 mm) Flow, Min. (2" Restriction) 57 CFM (16.4 m 3 /min) 555 CFM (15.7 m 3 /min) Flow, Max. (12" Restriction) 1275 CFM (36.1 m 3 /min) 1224 CFM (34.7 m 3 /min) Secondary Element No Yes Housing Material Metal Metal Pre-cleaner Integral Yes Yes Dust Holding Capacity per Cummins Specification Specification AH19273 AH1974 Allowable Flow for 1 g/cfm < 1275 CFM (36.1 m 3 /min)* 1224 CFM (34.7 m 3 /min)* Allowable Flow for 25 g/cfm < 938 CFM (26.6 m 3 /min) 917 CFM (26. m 3 /min) * Flow rate limited by restriction. Specifications subject to change without notice. 5-9 cumminsfiltration.com

91 Metal Air Cleaners AH1973 AH1974 Ordering Information Part Number AH1973 AH1974 Dimensions 1. (254.) 7. (177.8) Air Cleaners Metal Air Cleaner without Secondary Element Metal Air Cleaner with Secondary Element 4.6 (116.8) 22. (559) Allowance for Element Removal Accessories S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S S Weather Hood S Hump-Hose S 9 Elbow S S 9 Reducing Elbow S S Restriction Indicator (575.1) (625.9) 4.62 (117.3) 2. (5.8) INLET 1.62 (41.1).25 (6.35) 1/8" - 27 NPT Filtered Male Pressure Tap Service Parts AF4553M Primary Element AF4553M Magnum Primary Element AF4554M Secondary Element S Dust Ejection Valve S Wing Nut/Clips N/A Cover Assembly 16.1 (48.9) Body 7. (177.8) OUTLET 3. (76.2) All dimensions are in inches (millimeters) 3.4 (86) Performance System Restriction vs Flow Rate 2.2 (51.3) Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH AH Restriction (kpa) Capacity (g) AH1974 AH Restriction Flow Rate ( ) = with Secondary Flow Rate ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (832) 23.9 (23.56) 2457 (23938) (967) (27.39) (22166) (198) 32.3 (31.1) 213 (19751) (1224) (34.66) (16757) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-91

92 AH1975 AH1976 Metal Air Cleaners Inlet Outlet Dust Ejection Valve Specifications Specification AH1975 AH1976 Length Overall 27.3" (693. mm) 27.3" (693. mm) Body, Max. 18.1" (46.2 mm) 18.1" (46.2 mm) Flow, Min. (2" Restriction) 7 CFM (19.8 m 3 /min) 65 CFM (18.4 m 3 /min) Flow, Max. (12" Restriction) 1815 CFM (51.4 m 3 /min) 1765 CFM (5. m 3 /min) Secondary Element No Yes Housing Material Metal Metal Pre-cleaner Integral Yes Yes Dust Holding Capacity per Cummins Specification Specification AH19273 AH1974 Allowable Flow for 1 g/cfm < 1815 CFM (51.4 m 3 /min)* 1765 CFM (5. m 3 /min)* Allowable Flow for 25 g/cfm < 132 CFM (37.4 m 3 /min) 126 CFM (35.9 m 3 /min) * Flow rate limited by restriction. Specifications subject to change without notice cumminsfiltration.com

93 Metal Air Cleaners AH1975 AH1976 Ordering Information Part Number AH1975 AH1976 Dimensions.25 Dia. Hanger Hole 1.5 (38.1) 11.5 (292) Air Cleaners Metal Air Cleaner without Secondary Element Metal Air Cleaner with Secondary Element 3.75 (95.3).5 (12.7) 1/8" NPT Filtered Pressure Tap Accessories S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S Weather Hood S Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator 27. (686) Allowance for Element Removal 2.4 (518) 1. (254.) 27.3 (693) INLET Service Parts AF25544 Primary Element N/A Magnum Primary Element AF25545 Secondary Element S Dust Ejection Valve S Wing Nut/Clips N/A Cover Assembly 1.71 (43.4).25 (6.4) 1.75 (44.5) (46.2) Body 8. (23.2) 14.8 (376) 3. (76.2) All dimensions are in inches (millimeters) OUTLET Performance System Restriction vs Flow Rate 2.45 (62.2) Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH AH AH1976 AH Restriction (kpa) Capacity (g) Restriction Flow Rate ( ) = with Secondary Typical Capacity ( ) = with Secondary in H 2 O kpa CFM m 3 /min grams (1211) 35.4 (34.3) (32113) (1418) (4.16) 349 (29169) (16) (45.31) 26181(2585) (1765) (49.98) (22266) ISO Coarse Dust 2. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-93

94 AH1977 Metal Air Cleaners Inlet Outlet Specifications Specification Length Overall Body Flow, Min. (2" Restriction) Flow, Max. (12" restriction) Secondary Element Housing Material Pre-cleaner Integral AH " (454.9 mm) 7.2" (182.4 mm) 188 CFM (5.3 m 3 /min) 468 CFM (13.3 m 3 /min) No Metal No Dust Holding Capacity per Cummins Specification Specification AH1977 Allowable Flow for 3 g/cfm < 329 CFM (9.3 m 3 /min) Allowable Flow for 1 g/cfm < 181 CFM (5.1 m 3 /min) Specifications subject to change without notice cumminsfiltration.com

95 Metal Air Cleaners AH1977 Ordering Information Part Number AH1977 Dimensions 6.69 (169.9) 1.5 (38.1) Air Cleaner Metal Air Cleaner 4. (11.6) 16. (46) Ref. Allowance for Element Removal Accessories S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S Weather Hood S Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator (454.9) (389.9) (34.) INLET AF25546 N/A N/A N/A Service Parts Primary Element Magnum Primary Element Secondary Element Dust Ejection Valve S S Wing Nut/Clips S Cover Assembly 2.56 (65.) 1.5 (38.1) 1/8" NPT Filtered Male Pressure Tap 7.18 (182.4) Body 4. (11.6) OUTLET All dimensions are in inches (millimeters) Performance System Restriction vs Flow Rate Typical System Capacity vs Flow Rate Restriction (inch H 2 O) Restriction (kpa) AH AH Capacity (g) Restriction Flow Rate Typical Capacity in H 2 O kpa CFM m 3 /min grams ISO Fine Dust 1. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-95

96 AH1978 Metal Air Cleaners Inlet Outlet Specifications Specification Length Overall Body Flow, Min. (2" Restriction) Flow, Max. (12" Restriction) Secondary Element Housing Material Pre-cleaner Integral AH " (547.1 mm) 8.5" (216.4 mm) 31 CFM (8.8 m 3 /min) 791 CFM (22.4 m 3 /min) No Metal No Dust Holding Capacity per Cummins Specification Specification Allowable Flow for 3 g/cfm Allowable Flow for 1 g/cfm AH1978 < 52 CFM (14.7 m 3 /min) < 25 CFM (7.1 m 3 /min) Specifications subject to change without notice cumminsfiltration.com

97 Metal Air Cleaners AH1978 Ordering Information Air Cleaner Accessories Service Parts Part Number AH1978 Metal Air Cleaner S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S Weather Hood S Hump-Hose S 9 Elbow N/A 9 Reducing Elbow S Restriction Indicator AF25547 N/A N/A N/A Primary Element Magnum Primary Element Secondary Element Dust Ejection Valve S S Wing Nut/Clips S Cover Assembly Dimensions 8.52 (216.4) Body 5. (127.) 2.51 (63.8) 19. (483) Allowance for Element Removal INLET (547.1) (3.) 2.56 (65.) 1.5 (38.1) 6.77 (172.).25 (6.4) 5. (127.) OUTLET Performance System Restriction vs Flow Rate Restriction (inch H 2 O) AH Restriction (kpa) All dimensions are in inches (millimeters) Typical System Capacity vs Flow Rate Capacity (g) AH Restriction Flow Rate Typical Capacity in H 2 O kpa CFM m 3 /min grams ISO Fine Dust 1. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-97

98 AH1979 Metal Air Cleaners Inlet Outlet Specifications Specification Length Overall Body Flow, Min. (2" Restriction) Flow, Max. (12" Restriction) Secondary Element Housing Material Pre-cleaner Integral AH " (585.7 mm) 1.1" (256.5 mm) 465 CFM (13.2 m 3 /min) 1156 CFM (32.7 m 3 /min) No Metal No Dust Holding Capacity per Cummins Specification Specification Allowable Flow for 3 g/cfm Allowable Flow for 1 g/cfm AH1979 < 692 CFM (19.6 m 3 /min) < 329 CFM (9.3 m 3 /min) Specifications subject to change without notice cumminsfiltration.com

99 Metal Air Cleaners AH1979 Ordering Information Part Number AH1979 Dimensions 2.59 (65.8) 7.64 (194.1) Air Cleaner Metal Air Cleaner 1.1 (256.5) 6. (152.4) 2. (58.) Allowance for Element Removal Accessories S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S S Weather Hood S Hump-Hose S 9 Elbow S S 9 Reducing Elbow S Restriction Indicator 23.6 (585.7) 19.9 (55.5) (367.) INLET Service Parts AF25548 Primary Element N/A Magnum Primary Element N/A Secondary Element N/A Dust Ejection Valve S S Wing Nut/Clips S Cover Assembly 3.16 (8.3) 1.6 (4.6).25 (6.4) 1/8" NPT Filtered (Male) Pressure Tap With Cap 6. (152.4) OUTLET Performance System Restriction vs Flow Rate All dimensions are in inches (millimeters) Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH1979 AH Restriction (kpa) Capacity (g) Restriction Flow Rate Typical Capacity in H 2 O kpa CFM m 3 /min grams ISO Fine Dust 1. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-99

100 AH198 Metal Air Cleaners Inlet Outlet Specifications Specification Length Overall Body Flow, Min. (2" Restriction) Flow, Max. (12" Restriction) Secondary Element Housing Material Pre-cleaner Integral AH " (583.2 mm) 1." (255. mm) 47 CFM (13.3 m 3 /min) 1217 CFM (34.5 m 3 /min) No Metal No Dust Holding Capacity per Cummins Specification Specification Allowable Flow for 3 g/cfm Allowable Flow for 1 g/cfm AH198 < 956 CFM (27.1 m 3 /min) < 473 CFM (13.4 m 3 /min) Specifications subject to change without notice. 5-1 cumminsfiltration.com

101 Metal Air Cleaners AH198 Ordering Information Part Number AH198 Dimensions Air Cleaner Metal Air Cleaner Accessories S Mounting Bracket 2 No. of Brackets Required S Outlet Band Clamps S S Weather Hood S Hump-Hose S 9 Elbow S S 9 Reducing Elbow S Restriction Indicator Service Parts AF25549 Primary Element N/A Magnum Primary Element N/A Secondary Element N/A Dust Ejection Valve S S Wing Nut/Clips S Cover Assembly (3.) 7. (177.8) 4.14 (15.2) 1.4 (255.) 2. (58.) Allowance for Element Removal (583.2) 15. (381.) INLET 2.7 (69) 1.5 (38.1).25 (6.4) 1/8" NPT Filtered Pressure Tap 6. (152.4) OUTLET Performance System Restriction vs Flow Rate All dimensions are in inches (millimeters) Typical System Capacity vs Flow Rate Restriction (inch H 2 O) AH AH Restriction (kpa) Capacity (g) Restriction Flow Rate Typical Capacity in H 2 O kpa CFM m 3 /min grams ISO Fine Dust 1. g/m 3 Feed Rate 6.25 kpa (25" H 2 O) Terminal Restriction cumminsfiltration.com 5-11

102 Notes 5-12 cumminsfiltration.com

103 Disposable Air Cleaners cumminsfiltration.com 5-13

104 Throw-Away Style ECB Style Disposable Air Cleaners Throw-Away Style Features Disposable Throw-Away Plastic Housing Over 99% Efficiency Wide Range of Low to Medium Dust Concentration Applications Low Initial Cost Filter Elements Included A Air Inlet D Air to Engine C Mounting Base Part Number Body Dia. A C Length D Airflow CFM Airflow m 3 /min 6" H 2 O 8" H 2 O 1" H 2 O 1.5 kpa 2. kpa 2.5 kpa AH (442) 5.5 (14) 14.6 (37) AH (53) 5.5 (14) 17.8 (453) ECB Style Replaces Donaldson ECB Duralite Style Disposable Housings and Filters Applications Light and Medium Duty Engines Gas and Diesel Powered Vehicles and Equipment Outlet B Outlet Length = 1.38 in (35 mm) C A Expanded Metal Liner Inlet Part Number Body Dia. A Outlet ID B Length C Airflow CFM Airflow m 3 /min 4" H 2 O 6" H 2 O 8" H 2 O 1 kpa 1.5 kpa 2 kpa AH (215.9) 3 (76.2) 11 ( 279.4) A AH (215.9) 4 (11.6) 11 ( 279.4) A AH (215.9) 3 (76.2) 3 (76.2) A AH (215.9) 3 (76.2) 8.5 (215.9) A AH (215.9) 4 (11.6) 11 ( 279.4) B AH (215.9) 3 (76.2) 11 ( 279.4) B AH (266.7) 4 (11.6) 1.5 (266.7) B AH (266.7) 4 (11.6) 1.5 (266.7) A AH (317.5) 6 (152.4) 15 (381.) C * A = Standard B = Treated for higher humidity (marine applications, for example) C = Reinforced to withstand higher pulsation applications Media Type* 5-14 cumminsfiltration.com

105 Disposable Air Cleaners ECC Style ECD Style ECC Style Replaces Donaldson ECC Duralite Style Disposable Housings and Filters Applications Light and Medium Duty Engines Gas and Diesel Powered Vehicles and Equipment Outlet B Outlet Length = 1.38 in (35 mm) C A Slotted Inlet Part Number Body Dia. A B Length C Airflow CFM Airflow m 3 /min 4" H 2 O 6" H 2 O 8" H 2 O 1 kpa 1.5 kpa 2 kpa AH (215.9) 3 (76.2) 9.5 (241.35) C AH (215.9) 3 (76.2) 5 (127.) C AH (266.7) 4 (11.6) 6 (152.4) A AH (215.9) 2.5 (63.5) 6.5 (165.1) C AH (266.7) 4 (11.6) 1.5 (266.7) A AH (215.9) 2.5 (63.5) 4 (11.6) C AH (215.9) 2.5 (63.5) 9.5 (241.3) C AH (139.7) 1.75 (44.45) 4 (11.6) C AH (114.3) 1.5 (38.1) 4.5 (114.3) C AH (317.5) 5 (127.) 11 (279.4) A AH (165.1) 2 (5.8) 7.5 (19.5) C * A = Standard B = Treated for higher humidity (marine applications, for example) C = Reinforced to withstand higher pulsation applications Media Type ECD Style Replaces Donaldson ECD Duralite Style Disposable Housings and Filters Applications Outlet Outlet Length = 1.38 in (35 mm) Light and Medium Duty Engines Gas and Diesel Powered Vehicles and Equipment B C A Slotted Inlet Part Number Body Dia. A B Length C Airflow CFM Airflow m 3 /min 4" H 2 O 6" H 2 O 8" H 2 O 1. kpa 1.5 kpa 2. kpa AH (114.3) 1.5 (38.1) 4.5 (114.3) cumminsfiltration.com 5-15

106 ECO II Disposable Air Cleaners ECO II Single-Stage Air Cleaner for Medium-Duty Service Its unique, tapered, offset, and oversized element in a highly efficient, compact design makes the ECO II today's leading choice for many stationary engine applications. The revolutionary design results in greatly reduced intake air restriction, and provides maximum airflow to the engine. Features 99.9% Efficiency Component ECO II Air Cleaner Optional Inlet Adapter Combination Water Separator and Inlet Adapter Hose Clamps (2 Required) Pressure Tap Sleeve (with Service Indicator) 1/8" NPT Tap Pressure Tap Sleeve (with Service Indicator) 1/8" NPT and 3/4" NPT Taps Pressure Tap Sleeve (with Service Indicator) 1/8" NPT Tap Pressure Tap Sleeve (with Service Indicator) 1/8" NPT and 3/4" NPT Taps Diameter Length Normal Rated Airflow CFM 8 in H 2 O Normal Rated Airflow m 3 /min 8 in H 2 O Intake Dia Outlet Dia 9.75 (248) 24 (61) 11 Grid 6 (152) AH (279) 24 (61) 138 Grid 7 (178) AH113F/ AH (343) 15 (381) 16 Grid 7 (178) AH (343) 18 (457) 16 Grid 7 (178) AH (343) 24 (61) 16 Grid 7 (178) AH (248) 6 (152) S 11. (279) 6 (152) S 11. (279) 7 (178) S 13.5 (343) 7 (178) S 9.75 (248) 6 (152) S 11. (279) 6 (152) S 11. (279) 7 (178) S 13.5 (343) 7 (178) S 9.75 (248) S 11. (279) S 13.5 (343) S 6 (152) 6 (152) S 6 (152) 6 (152) S 7 (178) 7 (178) S 7 (178) 7 (178) S 5-16 cumminsfiltration.com

107 Disposable Air Cleaners ECO-SE ECO-SE For Light and Medium Duty Applications The ECO-SE is perfect for today's smaller fleet and stationary engines up to 25 hp. Its compact size, light weight, ease of service, and high efficiency combine to provide the critical engine protection and simplified maintenance cost-conscious equipment operators now require. A B Features Integral neoprene outlet for easy installation and service 99.9% efficiency C Component ECO-SE Air Cleaner Body Dia. A Outlet ID B Length C Airflow CFM Airflow m 3 /min 4" H 2 O 6" H 2 O 8" H 2 O 1. kpa 1.5 kpa 2. kpa Part Number 6.8 (171.5) 3 (76.2) (36) AH (169.9) 4 (11.6) (435) AH (247.7) 5 (127.) 2.16 (512) AH (152.4) 5 (127.) 19.4 (493) AH1197 Component Diameter Part Number Mounting Clamps (2 Required) 6.75 (171.5) S 7.75 (169.9) S 9.75 (247.7) S cumminsfiltration.com 5-17

108 Notes 5-18 cumminsfiltration.com

109 Hump Hoses/Hump Hose Reducers D A C Hump Hose Reducers ID B A Hump Hoses ID A B C Part Number 3. (76.2) 5.25 (133.35) 4.5 (114.3) 2. (5.8) S 3.5 (88.9) 5.25 (133.35) 5. (127.) 2. (5.8) S 4. (11.6) 5.25 (133.35) 5.37 (136.4) 2. (5.8) S 4.5 (114.3) 5.25 (133.35) 5.87 (149.1) 1.75 (44.45) S 5. (127.) 6. (152.4) 6.12 (155.45) 2.25 (57.15) S 5.5 (139.7) 6. (152.4) 7. (177.8) 2.25 (57.15) S 6. (152.4) 6. (152.4) 7.5 (19.5) 2.75 (69.85) S 7. (177.8) 7. (177.8) 8.5 (215.9) 2.5 (63.5) S 8. (23.2) 5. (127.) 9.5 (241.3) 1.5 (38.1) S 1. (254.) 6. (152.4) 11.5 (292.1) 2. (5.8) S A C B B C D Part Number 3. x 2.5 (76.2 x 63.5) 4.5 (114.3) 4.25 (17.95) 2.12 (53.85) 3. (76.2) 912K 3.5 x 3. (88.9 x 76.2) 5. (127.) 5. (127.) 2.12 (53.85) 2.12 (53.85) S 4. x 3. (11.6 x 76.2) 5.25 (133.35) 5.5 (139.7) 1.5 (38.1) 1.75 (44.45) S 5. x 4. (127. x 11.6) 6. (152.4) 6.5 (165.1) 1.5 (38.1) 1.75 (44.45) S 5.5 x 4. (139.7 x 11.6) 6. (152.4) 7. (177.8) 1.87 (47.5) 2. (5.8) S 5.5 x 5. (139.7 x 127.) 6. (152.4) 7. (177.8) 1.87 (47.5) 2. (5.8) S 6. x 5. (152.4 x 127.) 6. (152.4) 7.5 (19.5) 1.87 (47.5) 2. (5.8) S 6. x 5.5 (152.4 x 139.7) 6. (152.4) 7.5 (19.5) 2. (5.8) 2. (5.8) S 7. x 5.5 (177.8 x 139.7) 7. (177.8) 8.5 (215.9) 2.25 (57.15) 2.75 (69.85) S 7. x 6. (177.8 x 152.4) 6. (152.4) 8.5 (215.9) 1.44 (36.58) 1.5 (38.1) S 8. x 5.5 (23.2 x 139.7) 7. (177.8) 9.5 (241.3) 1.75 (44.45) 1.75 (44.45) S 8. x 6. (23.2 x 152.4) 6. (152.4) 9.5 (241.3) 1.38 (35.5) 1.5 (38.1) S 8. x 7. (23.2 x 177.8) 6. (152.4) 9.5 (241.3) 1.44 (36.58) 1.5 (38.1) S 1. x 8. (254. x 23.2) 6. (152.4) 11.5 (292.1) 1.75 (44.45) 2. (5.8) S Air Intake Components cumminsfiltration.com 5-19

110 Weather Hoods B A A Style 1 Style 2 B B C A A Style 3 B A Style (457.2) Style 5 B B C 11.9 (32.3) C C C Weather Hoods (Styles 1 6) Style A (ID) B C Material Finish Part Number 2 2. (5.8) 4.6 (116.8) 3.3 (83.8) Metal Black S (63.5) 5.8 (147.3) 3.9 (99.1) Metal Primer S 2 3. (76.2) 6.6 (167.6) 5. (127.) Metal Primer S (94.) 9.5 (241.3) 8. (23.2) Metal Black S 1 4. (11.6) 9.5 (241.3) 8. (23.2) Metal Black S 3 5. (127.) 9.5 (241.3) 5. (127.) Metal Black S 3 6. (152.4) 9.5 (241.3) 5. (127.) Metal Black S 6 6. (152.4) 13. (33.2) 4.1 (14.1) Plastic Stainless* S 6 7. (177.8) 13. (33.2) 3.8 (96.5) Plastic Stainless* S 4 7. (177.8) 17. (431.8) 6.8 (172.7) Metal Black S 3 7. (177.8) 16.2 (411.5) 7.9 (2.7) Metal Black S 3 1. (254.) 19.2 (487.7) 7.9 (2.7) Metal Black S * Stainless cap is polished to match chrome appearance. Weather Hoods (Style 5) Style A (ID) B Black Finish Chrome Finish (139.7) 9.6 (244.6) S S 5 6. (152.4) 9.5 (241.3) S S 5 7. (177.8) 9.3 (236.5) S S 5 8. (23.2) 8.1 (26.4) S S Weather Hoods (Style 7, Composite) Air Intake Components A A Style 6 Style B (ID) C A Part Number (44.45) 5.51 (139.95) 2.81 (71.37) S 7 2. (5.8) 5.54 (14.72) 2.86 (72.64) S (63.5) 5.54 (14.72) 2.86 (72.64) S B B C Style 7 C A Style 8 Weather Hoods (Style 8, Composite) Style C (ID) A B (ID) Part Number 8 3. (76.2) 8. (23.2) 3.75 (95.25) S (95.25) 8. (23.2) 3.75 (95.25) S (114.3) 13.5 (342.9) 4.98 (126.49) S 8 5. (127.) 13.5 (342.9) 4.87 (123.7) S 8 6. (152.4) (293.88) 5.15 (13.81) S 8 7. (177.8) 13.5 (342.9) 4.45 (113.3) S 5-11 cumminsfiltration.com

111 Air Intake Components Mounting Brackets Metal Mounting Brackets F D A G C B E A B C D E F 4.4 (111.76).88 (22.35) 4. (11.6) 2.5 (63.5).344 (8.74).5 (12.7) S 5.25 (133.35).88 (22.35) 3.25 (82.55) 3.12 (79.25).344 (8.74).5 (12.7) S 6.5 (165.1).88 (22.35) 3.75 (95.25) 3.75 (95.25).344 (8.74).5 (12.7) S 7.3 (185.42).88 (22.35) 4.25 (17.95) 4.15 (15.41).344 (8.74).5 (12.7) S 7.89 (2.41).88 (22.35) 4.25 (17.95) 4.44 (112.78).344 (8.74).5 (12.7) S 8. (23.2) 1.25 (31.75) 4.25 (17.95) 4.88 (123.95).46 (1.31).88 (22.35) S 8.5 (215.9).88 (22.35) 4.25 (17.95) 4.75 (12.65).344 (8.74).5 (12.7) S 9. (228.6) 1.25 (31.75) 4.5 (114.3) 5.38 (136.65).46 (1.31).88 (22.35) S 1.2 (259.8) 1.25 (31.75) 5. (127.) 5.98 (151.89).46 (1.31).88 (22.35) S 1.3 (261.62) 1.25 (31.75) 5. (127.) 6.3 (153.16).46 (1.31).88 (22.35) S 11. (279.4) 1.25 (31.75) 5. (127.) 6.38 (162.5).46 (1.31).88 (22.35) S 11. (279.4) 1.25 (31.75) 5. (127.) 6.38 (162.5).46 (1.31).88 (22.35) S* 11.8 (299.72) 1.25 (31.75) 6. (152.4) 6.78 (172.21).46 (1.31).88 (22.35) S 12.1 (37.34) 1.5 (38.1) 8. (23.2) 7.12 (18.85).469 (11.91) 1.6 (26.92) S 13. (33.2) 1.5 (38.1) 6. (152.4) 7.56 (192.2).469 (11.91) 1.6 (26.92) S* 13. (33.2) 1.5 (38.1) 6. (152.4) 7.56 (192.2).469 (11.91) 1.6 (26.92) S 14. (355.6) 1.5 (38.1) 8. (23.2) 8.6 (24.72).469 (11.91) 1.6 (26.92) S 15. (381.) 1.25 (31.75) 8. (23.2) 8.38 (212.85).46 (1.31).88 (22.35) S 16. (46.4) 1.25 (31.75) 1. (254.) 8.88 (225.55).46 (1.31).88 (22.35) S 18.1 (459.74) 1.5 (38.1) 8. (23.2) 1.12 (257.5).469 (11.91) 1.6 (26.92) S * = Stainless Steel G A F E B C D Mounting Brackets for Plastic Air Cleaners Wire Form Brackets for Plastic Air Cleaners Style For Use On A Bolt Hole Diameter Part Number 2 OptiAir 4 Series 4.63 (117.6).35 (9.) S 1 OptiAir 4 Series 4.63 (117.6).35 (9.) S 2 OptiAir 5 Series 5.62 (142.8).35 (9.) S 1 OptiAir 5 Series 5.62 (142.8).35 (9.) S A Style 1 A Style 2 For Use On A B C D E F G Part Number 4" & OptiAir 4 Series 4.77 (121.16) 6.45 (163.83) 1.57 (39.88).35 (8.89) 2.76 (7.1) 4. (11.6) 3.7 (77.98) S 5" & OptiAir 5 Series 5.72 (145.2) 7.39 (187.71) 1.98 (5.29).35 ( (8.1) 4.38 (111.25) 3.54 (89.92) S 6" & OptiAir 6 Series 6.5 (165.1) 8.32 (211.33) 1.98 (5.29).35 ( (89.92) 4.75 (12.65) 3.95 (1.33) S 7" Mounting Bracket 7.17 (182.12) 8.74 (222.) 1.98 (5.29).35 ( (1.8) 5.25 (133.35) 4.15 (15.41) S 8" & OptiAir 8 Series 8.32 (211.33) 9.88 (25.95) 1.98 (5.29).35 ( (11.24) 5.56 (141.22) 4.72 (119.98) S 1" & OptiAir 1 Series 9.83 (249.68) (296.67) 1.25 (31.75).46 (1.31) 6. (152.4) 8.5 (215.9) 5.78 (146.81) S 11" & OptiAir 11 Series (288.29) (334.26) 1.25 (31.75).46 (1.31) 6.5 (165.1) 8.5 (215.9) 6.5 (165.1) S 13" & OptiAir 13 Series (336.4) 15.7 (382.78) 1.25 (31.75).46 (1.31) 8. (23.2) 11. (279.4) 8. (23.2) S cumminsfiltration.com 5-111

112 Hose Clamps Dust Ejection Valves Air Intake Components Hose Clamps Nominal Connection* Actual Clamp ID 2. (5.8) ( ) S 2.5 (63.5) ( ) S 3. (76.2) ( ) S 3.5 (88.9) ( ) S 4. (11.6) ( ) S 4.5 (114.3) ( ) S 5. (127.) ( ) S 5.5 (139.7) ( ) S 6. (152.4) ( ) S 7. (177.8) ( ) S 8. (23.2) ( ) S 1. (254.)** ( ) S 1. (254.)*** ( ) S * Nominal ID dimension shown corresponds to ID dimension of rubber part being clamped. ** For use with 45 and 9 Elbows. *** For use with Hump Hoses and Reducers. Dust Ejection Valves Size For Use On 1.5 (38.1) Plastic and Metal S 3. (76.2) Metal Only S cumminsfiltration.com

113 Air Intake Components Elbows A A C C B B Style 1 Style 2 45 Elbows Style ID A B C Part Number 1 3. (76.2) 3.5 (88.9) 1.6 (4.64) 1.6 (4.64) 5.5 (139.7) S (88.9) 4. (11.6) 1.68 (42.67) 1.68 (42.67) 5. (127.) S 1 4. (11.6) 4.5 (114.3) 1.46 (37.8) 1.46 (37.8) 5.5 (139.7) S 1 5. (127.) 5.5 (139.7) 1.36 (34.54) 1.36 (34.54) 5.5 (139.7) S (139.7) 6. (152.4) 1.7 (43.18) 1.7 (43.18) 6.25 (158.75) S 2 6. (152.4) 6.5 (165.1) 1.74 (44.2) 1.74 (44.2) 6.5 (165.1) S 2 7. (177.8) 7.62 (193.55) 2.38 (6.45) 2.38 (6.45) 8. (23.2) S 2 8. (23.2) 8.75 (222.25) 2. (5.8) 2. (5.8) 8.6 (24.72) S 2 1. (254.) 1.75 (273.5) 2.25 (57.15) 2.25 (57.15) 1.5 (266.7) S B B C 9 Elbows A C A A Style 1 Style 2 A Style ID A B C Part Number 1 2. (5.8) 2.4 (6.96) 3.5 (88.9) 1.5 (38.1) 1.5 (38.1) S (63.5) 3. (76.2) 4. (11.6) 1.5 (38.1) 1.5 (38.1) S 1 3. (76.2) 3.5 (88.9) 5.25 (133.35) 1.5 (38.1) 1.5 (38.1) S (88.9) 4. (11.6) 5.5 (139.7) 1.5 (38.1) 1.5 (38.1) S 1 4. (11.6) 4.5 (114.3) 5.75 (146.5) 1.25 (31.75) 1.25 (31.75) S (114.3) 5. (127.) 5.5 (139.7) 2. (5.8) 1.62 (41.15) S 1 5. (127.) 5.5 (139.7) 6.12 (155.45) 1.62 (41.15) 1.62 (41.15) S (139.7) 6. (152.4) 6.5 (165.1) 1.75 (44.45) 1.75 (44.45) S 2 6. (152.4) 6.5 (165.1) 6.75 (171.45) 2.25 (57.15) 2. (5.8) S 2 7. (177.8) 7.62 (193.55) 7.56 (192.2) 2.25 (57.15) 2. (5.8) S 2 8. (23.2) 8.75 (222.25) 8.5 (215.9) 2. (5.8) 2.25 (57.15) S 2 1. (254.) 1.75 (273.5) 1.5 (266.7) 2.25 (57.15) 2.25 (57.15) S cumminsfiltration.com 5-113

114 Reducing Elbows Air Intake Components E B E B C C F F D A Style 1 Reducing 45 Elbows D A Style 2 Style A ID (mm) B ID (mm) C D (in mm) E F Thickness Part Number 1 6. (152.4) 5. (127.) 6.44 (163.58) TBD 1.75 (44.45) 1.75 (44.45).25 (6.35) S 2 7. (177.8) 6. (152.4) 7.38 (187.45) TBD 2. (5.8) 2. (5.8).31 (7.87) S E B Reducing 9 Elbows A (ID) D A R C B (ID) Thickness C D E F Part Number 5. (127.) 6. (152.4).25 (6.35) 7. (177.8) 6. (152.4) 1.5 (38.1) 1.7 (43.18) S 5.5 (139.7) 6. (152.4).25 (6.35) 6.75 (171.45) 6.75 (171.45) 1.75 (44.45) 1.75 (44.45) S 5. (127.) 7. (177.8).25 (6.35) 7. (177.8) 6.25 (158.75) 1.75 (44.45) 2.75 (69.85) S 5.5 (139.7) 7. (177.8).31 (7.87) 5.75 (146.5) 6.25 (158.75) 1.5 (38.1) 1.5 (38.1) S 6. (152.4) 7. (177.8).38 (9.65) 9. (228.6) 7.56 (192.2) 3. (76.2) 3. (76.2) S cumminsfiltration.com

115 Air Intake Components Reducer Inlet Sleeves C A B D A E Reducer Inlet Sleeves B C D E Part Number 1.75 (44.45) 2.5 (63.5) 2. (5.8) 1. (25.4).25 (6.35) S 1.38 (35.5) 2.5 (63.5) 2. (5.8) 1. (25.4).25 (6.35) S 2.5 (63.5) 3.5 (88.9) 3. (76.2) 1. (25.4).25 (6.35) S 2.25 (57.15) 3.5 (88.9) 3. (76.2) 1. (25.4).25 (6.35) S 2. (5.8) 3.5 (88.9) 3. (76.2) 1. (25.4).25 (6.35) 3932 S 3.75 (95.25) 4.5 (114.3) 4. (11.6) 1.5 (38.1).25 (6.35) S 4. (11.6) 5. (127.) 4.5 (114.3) 1.5 (38.1).25 (6.35) S 3.75 (95.25) 5. (127.) 4.5 (114.3) 1.5 (38.1).25 (6.35) S 3. (76.2) 5. (127.) 4.5 (114.3) 1.5 (38.1).25 (6.35) S 4.5 (114.3) 5.5 (139.7) 5. (127.) 1.5 (38.1).25 (6.35) S 4. (11.6) 5.5 (139.7) 5. (127.) 1.5 (38.1).25 (6.35) 3954 S 5. (127.) 6. (152.4) 5.5 (139.7) 1.5 (38.1).25 (6.35) S 5. (127.) 6.5 (165.1) 6. (152.4) 1.5 (38.1).5 (12.7) S 5.5 (139.7) 6.5 (165.1) 6. (152.4) 1.5 (38.1).25 (6.35) S cumminsfiltration.com 5-115

116 Notes cumminsfiltration.com

117 Take the uncertainty and extra costs out of air filter maintenance. A Restriction Indicator automatically and continually monitors the condition of your air filters. The best preventative engine maintenance practice would be to ensure that air filters are only replaced when necessary. Changing a filter more often than necessary increases the risk of dirt reaching the engine. The disturbed dust can enter the intake near the filter sealing gasket area within the housing as the old filter is removed. Most of the dust that passes through a new air filter occurs in the first third of its useful life. Changing a filter too early doesn't utilize the best dirt removal efficiency, which occurs in the last two thirds of its service life. Single Position Indicator Single Position Indicator with Electrical Switch Type Inches of H 2 O kpa Features Constant restriction readings allow accurate checks on filter restriction, even after shutdown Eliminates air cleaner over-servicing Saves fuel Saves costs Reduces the chance of engine failure due to dirt entering the system Easy and safe to use Quick to install Manual reset Height Graduated Indicator with Electrical Switch Port Size Part Number (46).125 (3.18) S Single Position (46).125 (3.18) S Single Position with Electrical Switch (59).125 (3.18) S (7).125 (3.18) S Graduated (7).125 (3.18) S Graduated with Electrical Switch (79).125 (3.18) S Non-Locking Electrical Air Switch This Restriction Indicator with an electrical switch can turn a light on within the vehicle when the restriction reaches a level where the filter should be changed. No reset switch is required since the light turns off automatically when the air flow and restriction decrease S Graduated Indicator Remote Mount Kit (Not Shown) Includes a 3" (762 mm) hose, male and female barb fittings, and a plastic mount bracket. This kit can be used with any of the Restriction Indicators shown here S Restriction Indicators cumminsfiltration.com 5-117

118 Notes cumminsfiltration.com

119 Pre-Cleaners Why Use a Pre-Cleaner? Why Use a Pre-Cleaner? Pre-Cleaners extend air filter life by reducing the amount of dust and/or debris that reaches the air filter There are two types of pre-cleaners available ingestive and ejective Pre-Cleaners Visibowl Pre-Cleaners (Ingestive) Ingestive systems collect debris and require maintenance, either emptying or cleaning. Removes 7 85% of dust and debris Collects all separated debris in bowl and stops when bowl is full Variable efficiency curve dependent on air flow Fleetguard Pre-Cleaners (Ejective) Ejective systems eject debris and are maintenance free. Removes up to 88% of dust and debris Ejects all separated debris pre-cleans continuously High, flat efficiency curve Simply empty the bowl when it is full Best suited for dust and smaller debris Bowl is made from a heavy duty polymer with increased UV protection to prevent cracking and discoloration. Must be mounted vertically Maintenance free Best suited for heavier than air debris, including dust, rain, sawdust, chaff, etc. Housing is made from high-quality, non-reflective, non-corroding Nylon 6-6 polymer Can be mounted either vertically or horizontally One (1) year warranty Two (2) year warranty cumminsfiltration.com 5-119

120 Visibowl Pre-Cleaners Ordering Information Visibowl Reducing Adapter Flow Rate Part Number Intake Part Number From To CFM m 3 /min AP2 AP3 AP45 AP5 2. (5.8) 3. (76.2) 4.5 (114.3) 5. (127.) AP S 2. (5.8) 1.75 (44.45) S 2. (5.8) 1.38 (35.5) AP S 3. (76.2) 2.5 (63.5) S 3. (76.2) 2.25 (57.15) S 3. (76.2) 2. (5.8) AP S 4.5 (114.3) 4. (11.6) S 4.5 (114.3) 3.75 (95.25) S 4.5 (114.3) 3. (76.2) AP S 5. (127.) 4.5 (114.3) S 5. (127.) 4. (11.6) Expansion Adapter Visibowl Part Number Expansion Adapter From To AP S 5. (127.) 6. (152.4) Replacement Lids Replacement Bowls Visibowl Replacement Lid Part Number Visibowl Replacement Bowl Part Number AP S AP S AP S AP S AP S AP S AP S AP S B Dimensions D Part Number Outlet A Cover Width B Height C Cover Height D Body Width E C AP2 2. (5.8) 5.6 (142.2) 4.8 (121.9) 1.8 (45.7) 5.5 (139.7) AP3 3. (76.2 ) 7.5 (19.5) 6.2 (157.5) 1.8 (45.7) 7.3 (185.4) AP (114.3) 1.7 (271.8) 7.7 (195.6) 1.9 (48.2) 1.5 (266.7) A AP5 5. (127.) 12.1 (37.3) 7.7 (195.6) 2. (5.8) 12. (34.8) E 5-12 cumminsfiltration.com

121 Pre-Cleaners Fleetguard Extended air filter life Increased engine protection Reduced downtime Reduced maintenance costs Self-cleaning Lightweight Easy to install Durable polymer design The Benefits of Fleetguard Pre-Cleaners Fleetguard Pre-Cleaners are state of the art products that reduce maintenance costs and downtime for all diesel applications. They are recommended for the construction, farming, mining, forestry or any other segment where operating conditions are severe. Fleetguard Pre-Cleaners keep air filters clean, extend the life of the filter and maintain engine performance. Positioned at the beginning of the air intake, Fleetguard air Pre-Cleaners eject the majority of dust/dirt particles that are heavier than air. How the Fleetguard Pre-Cleaner Works 1 Dirty air passes through prescreen and enters through recessed vanes at the bottom of the Fleetguard Pre-Cleaner. 2 The curved particle accelerator rotates much faster than the incoming air, capturing debris, which is passed down the length of the particle accelerator s straked vanes. 3 4 The debris is then deposited on the inner wall of the separator chamber. As the particle accelerator spins, it sweeps debris that has deposited under the strakes onto the inner wall of the pre-cleaner, where it is ejected Clean air continues to spin upward, being compressed, and forced into the air inlet opening. 5 cumminsfiltration.com 5-121

122 Fleetguard Pre-Cleaners B C A Ordering Information To properly size a Fleetguard Pre-Cleaner, you will need to know the correct airflow of the engine in CFM (m 3 /min) and the Outside Diameter () of the air intake. For optimum efficiency, select the pre-cleaner where the CFM (m 3 /min) falls in the upper end of the ranges shown. Do not size a Fleetguard Pre-Cleaner solely based on the air intake dimension. Pre-cleaners should not be mounted against any part of the machine as space is needed to allow air to enter into the pre-cleaner. Cummins Filtration does not recommend putting pre-cleaners high in the air on an extended pipe as the further away the air intake is from the engine, the more added restriction. Part Number A Outlet B Width C Height CFM Flow Rate m 3 /min AP847 2 (5.8) 4.5 (114.3) 3 (76.2) AP848 3 (76.2) 6.7 (17.18) 4.2 (16.68) AP843 4 (11.6) 8.5 (215.9) 6.28 (159.51) AP849 4 (11.6) 8.5 (215.9) 6.28 (159.51) AP (127.) 1.6 (27)_ 7.9 (21) AP844 6 (152.4) 13.1 (332.74) 11.1 (281.94) AP841 6 (152.4) 13.1 (332.74) 11.1 (281.94) AP845 8 (23.2) 18 (457.2) ( ) AP846 8 (23.2) 18 (457.2) ( ) Installation Kits* Part Number Size in Adapts to Intake Size S 2 (5.8) 1/1.5/ /38.1/ S 3 (76.2) 2/2.5/ /63.5/ S 4 (11.6) 3/3.5/ /88.9/ S 4 (11.6) 4/4.5/4.75/5 11.6/114.3/12.65/ S 4 (11.6) 5.25/5.5/ /139.7/ S 4 (11.6) S 6 (152.4) S 6 (152.4) 4/5 11.6/ S 6 (152.4) 5/5.25/ /133.35/ S 6 (152.4) 6.25/6.5/ /165.1/ S 6 (152.4) S 6 (152.4) 7/1/ /254./ S 6 (152.4) S 8 (23.2) 6/ / S 8 (23.2) 7/ / S 8 (23.2) 1/ / S 8 (23.2) 12/ / S 8 (23.2) 6/ / S 8 (23.2) Special Kit mm * Installation Kits do not contain pre-cleaners, only the necessary adapters for installing a pre-cleaner to the matched intake sizes cumminsfiltration.com

123 Pre-Cleaners Accessories Rubber Reducing Adapters Use when your pre-cleaner is larger than your air intake pipe. From To S 2 (5.8) 1.5 (38.1) S 2 (5.8) 1.75 (44.45) S 3 (76.2) 2 (5.8) S 3 (76.2) 2.5 (63.5) S 3 (76.2) 2.75 (69.85) S 4 (11.6) 2.5 (63.5) S 4 (11.6) 2.75 (69.85) S 4 (11.6) 3 (76.2) S 4 (11.6) 3.75 (95.25) S 4 (11.6) 3.23 (82.4) S 5 (127.) 4.33 (19.98) S 5 (127.) 4 (11.6) From To S 5 (127.) 4.5 (114.3) S 5 (127.) 4.75 (12.65) S 6 (152.4) 5 (127.) S 6 (152.4) 5.25 (133.35) S 6 (152.4) 5.5 (139.7) S 7 (177.8) 6 (152.4) S 7 (177.8) 6.25 (158.75) S 7 (177.8) 6.5 (165.1) S 8 (23.2) 7 (177.8) S 9 (282.6) 8 (23.2) S 11 (279.4) 1 (254.) S 13 (33.2) 12 (34.8) Metal Expansion Adapters Use when your pre-cleaner is smaller than your intake. Metal Expansion Adapters are spun metal, designed to withstand the elements. Rubber Expansion Adapters Use when your pre-cleaner is smaller than your intake. Rubber Expansion Adapters are rubber pieces, designed to withstand the elements. From To S 4 (11.6) 5 (127.) S 4 (11.6) 6 (152.4) S 6 (152.4) 7 (177.8) S 6 (152.4) 9 (228.6) S 7 (177.8) 9 (228.6) S 8 (23.2) 13 (33.2) S 8 (23.2) 16 (46.4) From To S 4.25 (17.95) 4.5 (114.3) S 6.25 (158.75) 7 (177.8) Check Valve Use when your application requires the use of a Check Valve with the Fleetguard Pre-cleaner. Inlet () Outlet () S 1.5 (38.1) 1.5 (38.1) Material: Polypropylene (-4 to 18 F ( C) temperature range) Caution: Not intended for high temperature applications. cumminsfiltration.com 5-123

124 Accessories Pre-Cleaners Metal Extension Pipes Use when your pre-cleaner is below the hood line or you need more hood clearance underneath the pre-cleaner. A Diameter B Length S 4 (11.6) 12 (34.8) S 5 (127.) 12 (34.8) S 6 (152.4) 12 (34.8) S 7 (177.8) 14 (355.6) S 8 (23.2) 12 (34.8) A B Basket/Mesh Screens Use when operating in an environment with large debris (forestry, agriculture, landfill) to keep your pre-cleaner working at peak efficiency. Pre-Cleaner Size S Perforated Screen Kit 4 (11.6) S Perforated Screen Replacement 4 (11.6) S Perforated Screen Kit 6 (152.4) S Perforated Screen Replacement 6 (152.4) S Perforated Screen Kit 8 (23.2) S Perforated Screen Replacement 8 (23.2) S Wire Mesh Screen Kit 4 (11.6) S Wire Mesh Screen Kit 6 (152.4) S Wire Mesh Screen Kit 8 (23.2) Dust Ejection Valve Plugs Use to seal the dump valve portion of an internal or dust ejector pre-cleaner when the dump valve is removed. Size S 4 (11.6) S 5 (127.) S 6 (152.4) S 7 (177.8) S 8 (23.2) cumminsfiltration.com

FRG Air Cleaners. Superior Protection for Larger Engines RadialSeal Sealing Technology Means Reliable Filtration and Quicker Service

FRG Air Cleaners. Superior Protection for Larger Engines RadialSeal Sealing Technology Means Reliable Filtration and Quicker Service Superior Protection for Larger Engines RadialSeal Sealing Technology Means Reliable Filtration and Quicker Service The Donaldson two-stage FRG RadialSeal air cleaners provide improved reliability, better

More information

ISO 5011 Test Results

ISO 5011 Test Results ISO 5011 Test Results Certified to the ISO 5011 Air Filtration Standard Cold Air Intake Kit 2005-08 Ford Mustang GT V8-4.6L Part Number 75-5003 ISO 5011, Second Edition Performance Testing: Inlet Air Cleaning

More information

Superior Protection for Larger Engines Radial Seal Sealing Technology Means Reliable Filtration and Quicker Service

Superior Protection for Larger Engines Radial Seal Sealing Technology Means Reliable Filtration and Quicker Service Superior Protection for Larger Engines Radial Seal Sealing Technology Means Reliable Filtration and Quicker Service The Donaldson two-stage FRG radial seal air cleaners provide improved reliability, better

More information

TEST RESULTS. Certified to the ISO 5011 Air Filtration Standard

TEST RESULTS. Certified to the ISO 5011 Air Filtration Standard TEST RESULTS Certified to the ISO 5011 Air Filtration Standard 2001-04 GM Silverado/Sierra V8 8.1L HD S&B Cold Air Intake Kit Part # 75-3030-1 ISO 5011, Second Edition Performance Testing: Inlet Air Cleaning

More information

ISO 5011 Test Results

ISO 5011 Test Results ISO 5011 Test Results Certified to the ISO 5011 Air Filtration Standard Replacement Filter for AFE Intake Kit 1994-07 Dodge Ram Cummins 5.9L Diesel S&B Part Number: CR-90021 ISO 5011 Air Filtration Standard

More information

FPG & FPG Alexin Air Cleaners

FPG & FPG Alexin Air Cleaners & Alexin Air Cleaners Advanced Sealing Technology in Compact Two-Stage Design For the Most Reliable Engine Protection The Air Cleaner series is a two-stage engine air cleaner operating in medium to heavy

More information

TEST RESULTS. Certified to the ISO 5011 Air Filtration Standard

TEST RESULTS. Certified to the ISO 5011 Air Filtration Standard TEST RESULTS Certified to the ISO 5011 Air Filtration Standard 2003-2005 Dodge Ram Trucks L6 5.9L Diesel S&B OE Replacement Filter Part # 66-5007D ISO 5011, Second Edition Performance Testing: Inlet Air

More information

Service Access Cover. Vacuator Valve. Accessories

Service Access Cover. Vacuator Valve. Accessories Under Hood Mount, Two-Stage Filtration For Large Construction & Mining Equipment The FTG Cycloflow Air Cleaner is another two-stage air cleaner with a built-in pre-cleaner. This air cleaner has axial seal

More information

ISO 5011 Test Results

ISO 5011 Test Results ISO 5011 Test Results Certified to the ISO 5011 Air Filtration Standard Replacement Filter for AFE Intake Kit 2006-08 Duramax Chevrolet Silverado & GMC Sierra V8-6.6L Duramax LLY-LBZ S&B Part Number: CR-90038

More information

STG Donaclone Air Cleaners

STG Donaclone Air Cleaners STG Donaclone: Field Proven & Reliable Heavy-Duty Workhorse for Construction & Off-Highway Applications Donaldson s STG Donaclone air cleaner has been applied to a wide variety of heavy-duty equipment

More information

ISO 5011 Test Results

ISO 5011 Test Results ISO 5011 Test Results Certified to the ISO 5011 Air Filtration Standard Cold Air Intake Kit 1999-06 General Motors (GM) Trucks, Avalanche, Tahoe, Yukon, Suburban V8 4.8L, 5.3L & 6.0L Part Numbers: 75-5036

More information

TEST RESULTS. Certified to the ISO 5011 Air Filtration Standard

TEST RESULTS. Certified to the ISO 5011 Air Filtration Standard TEST RESULTS Certified to the ISO 5011 Air Filtration Standard 2003-05 Ford F-150 V8 4.6L S&B Cold Air Intake Kit Part # 75-2557 ISO 5011, Second Edition Performance Testing: Inlet Air Cleaning Equipment

More information

ISO 5011 Test Results

ISO 5011 Test Results ISO 5011 Test Results Certified to the ISO 5011 Air Filtration Standard Cold Air Intake Kit 2003-07 2003-07 Dodge Cummins 5.9L Diesel Part Numbers: 75-5047 75-5047D ISO 5011, Second Edition Performance

More information

ISO 5011 Test Results

ISO 5011 Test Results ISO 5011 Test Results Certified to the ISO 5011 Air Filtration Standard Cold Air Intake Kit 05-06 Dodge/Chrysler/300C 5.7L Hemi Part Number: 75-5008 (Cotton Filter) 75-5008D (Dry Filter) ISO 5011, Second

More information

TEST RESULTS. Certified to the ISO 5011 Air Filtration Standard

TEST RESULTS. Certified to the ISO 5011 Air Filtration Standard TEST RESULTS Certified to the ISO 5011 Air Filtration Standard 1999-05 GM Trucks & SUVs (Gas) S&B Performance Filter 66-2129D (Test Results for Parts Made After 5/1/06) ISO 5011, Second Edition Performance

More information

FPG & FPG Alexin Air Cleaners

FPG & FPG Alexin Air Cleaners Advanced Sealing Technology in Compact Two-Stage Design For the Most Reliable Engine Protection The Air Cleaner series is a two-stage engine air cleaner operating in medium to heavy dust conditions. The

More information

Cummins and Fleetguard are registered trademarks of Cummins, Inc. Mann+Hummel is a registered trademark of Mann+Hummel GMBH

Cummins and Fleetguard are registered trademarks of Cummins, Inc. Mann+Hummel is a registered trademark of Mann+Hummel GMBH MEDIUM DUST AIR CLEANERS Smaller, Lightweight Alternative Two-Stage Air Cleaner Designed for horizontal installation The FKB series is a family of twostage air cleaners for medium dust conditions. Compared

More information

Innovative Filtration Solutions

Innovative Filtration Solutions Innovative Filtration Solutions Baldwin s Channel Flow Air Filters... A Stronger Design For Outstanding Protection Improved Engine Protection Design traps contaminants within the filter, preventing them

More information

ISO 5011 Test Results

ISO 5011 Test Results ISO 5011 Test Results Certified to the ISO 5011 Air Filtration Standard Cold Air Intake Kit 1998-03 Ford F250/350/450 V8-7.3L Powerstroke Part Numbers: 75-5028 (Cotton Filter) 75-5028D (Dry Filter) ISO

More information

PowerCore Air Cleaners Two-Stage: PSD and Single-Stage: PCD

PowerCore Air Cleaners Two-Stage: PSD and Single-Stage: PCD PowerCore Air Cleaners Two-Stage: PSD and Single-Stage: PCD PowerCore air cleaners deliver... System design flexibility Metal-free, lightweight materials Rugged construction Straight-through airflow technology

More information

Filtration Products Extended service filters Increase engine protection Extend service intervals Reduce operating costs

Filtration Products Extended service filters Increase engine protection Extend service intervals Reduce operating costs Donaldson Filtration Products Extended service filters Increase engine protection Extend service intervals Reduce operating costs Oil Filters Air Filters Fuel Filters Hydraulic Filters Coolant Filters

More information

XLR TM. Next generation air filtration

XLR TM. Next generation air filtration XLR TM Next generation air filtration XLR TM Self-Cleaning Air With PowerCore media technology High performance: reduced initial pressure loss and long filter life for improved turbine efficiency and heat

More information

MANN Europiclon Two stage air cleaner modular system

MANN Europiclon Two stage air cleaner modular system MANN Europiclon Two stage air cleaner modular system Background picture: Claas 7 MANN Europiclon... Applications The MANN Europiclon is the ideal intake air cleaner for construction and agricultural machinery,

More information

ISO 5011 Test Results

ISO 5011 Test Results ISO 5011 Test Results Certified to the ISO 5011 Air Filtration Standard Cold Air Intake Kit 2004-05 Chevrolet Silverado & GMC Sierra V8-6.6L Duramax LLY Part Number 75-5038 ISO 5011, Second Edition Performance

More information

PowerCore Air Cleaners Two-Stage

PowerCore Air Cleaners Two-Stage Our Original PowerCore Brand is Changing! PowerCore Air Cleaners Two-Stage POWERCORE AIR CLEANERS to Section Index PSD... 30 Scavenge System Components... 38 PowerCore Air Cleaners for Cummins Engines...

More information

Ultra-Web HD. SSG Donaclone Air Cleaners. Designed for the Worst Dust Conditions New Choice for Construction and Off-Highway Applications

Ultra-Web HD. SSG Donaclone Air Cleaners. Designed for the Worst Dust Conditions New Choice for Construction and Off-Highway Applications HEAVY DUST AIR CLEANERS Designed for the Worst Dust Conditions New Choice for Construction and Off-Highway Applications The SSG Air Cleaner offers design improvements over our older SRG air cleaner style.

More information

PowerPleat Air Cleaners

PowerPleat Air Cleaners PowerPleat, 1 Protection for Large Equipment RadialSeal technology for quick and easy servicing Applications PowerPleat air cleaner provides up to cfm airflow. The PowerPleat 1 air cleaner provides up

More information

PowerPleat Air Cleaners

PowerPleat Air Cleaners POWERPLEAT AIR CLEANERS PowerPleat Compact, Durable All-plastic Housing Servicing is quick and easy Applications Provides up to cfm airflow without a safety filter and cfm airflow with a safety filter.

More information

MANN+HUMMEL IQORON The new compact air cleaner for high requirements

MANN+HUMMEL IQORON The new compact air cleaner for high requirements MANN+HUMMEL IQORON The new compact air cleaner for high requirements IQORON : An intelligent solution The newly developed IQORON air cleaner series from MANN+HUMMEL meets current and future requirements

More information

Our older, classic EBA cowl-mounted air cleaner (shown on the right) has been replaced with our ERA Air Cleaner.

Our older, classic EBA cowl-mounted air cleaner (shown on the right) has been replaced with our ERA Air Cleaner. Air Cleaners Cowl-Mounted Air Cleaner Superior Protection with RadialSeal Sealing Technology Looking for a replacement to our older EBA cylindrical-shaped axial seal style air cleaner? Our RadialSeal air

More information

10 Hydraulic Filters

10 Hydraulic Filters 1 Hydraulic Filters Introduction.... 1- HF65 Series.... 1-9 HF66 Series.... 1-15 HF67 Series.... 1-21 HF68 Series.... 1-1 Dual Spin-On Assembly.... 1-5 Introduction Hydraulic Filtration Systems Cummins

More information

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Catalog & SalesManual

Catalog & SalesManual Catalog & SalesManual Innovations in air filtration Grounds Care griculture Construction Forestry Mining Marine Utility Plastic ir Cleaners Metal ir Cleaners Precleaners luminum / Stainless Composite Cab

More information

AMSOIL Ea Oil, Bypass and Air Filters

AMSOIL Ea Oil, Bypass and Air Filters AMSOIL Ea Oil, Bypass and Air Filters RACING AIR FILTERS BYPASS FILTERS OIL FILTERS Advanced oil and air filtration technology from AMSOIL helps improve engine life and reduce maintenance costs. AMSOIL

More information

Air Cleaners for Heavy Dust Conditions S Series

Air Cleaners for Heavy Dust Conditions S Series Heavy-Duty Two-Stage Filtration for Diesel Engines Operating in Severe Dust Conditions Heavy construction vehicles (haul trucks, crawlers, dozers), above ground and underground mining machines, agricultural

More information

Installation manual. Intake system and ventilation. Industrial engines DC09, DC13, DC16 OC16. 01:02 Issue 10 en-gb. Scania CV AB 2018, Sweden

Installation manual. Intake system and ventilation. Industrial engines DC09, DC13, DC16 OC16. 01:02 Issue 10 en-gb. Scania CV AB 2018, Sweden Installation manual Intake system and ventilation Industrial engines DC09, DC13, DC16 OC16 01:02 Issue 10 en-gb Changes from the previous issue...3 Intake air...4 Intake air taken from outside engine room...

More information

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS AH12 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

SSG Donaclone Air Cleaners

SSG Donaclone Air Cleaners HEAVY DUST AIR CLEANERS Designed for the Worst Dust Conditions New Choice for Construction and Off-Highway Applications The SSG Air Cleaner offers design improvements over our older SRG air cleaner style.

More information

HeliFlow Industrial Series. Positive Displacement Blowers & Vacuum Pumps

HeliFlow Industrial Series. Positive Displacement Blowers & Vacuum Pumps HeliFlow Industrial Series Positive Displacement lowers & Vacuum Pumps 2 GD HeliFlow uilt y the Industry Leaders GD HeliFlow HeliFlow integrates proven experience with blower design and manufacturing techniques

More information

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING -

More information

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND RANGE HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

AMSOIL Ea Air, Oil and By-Pass Filters

AMSOIL Ea Air, Oil and By-Pass Filters AMSOIL Ea Air, Oil and By-Pass Filters AIR FILTERS BY-PASS FILTERS OIL FILTERs Advanced air and oil filtration technology from AMSOIL helps improve engine life and reduce maintenance costs. Ea Air Filters

More information

THE CLEANEST FUEL. PERIOD.

THE CLEANEST FUEL. PERIOD. Donaldson Delivers Front Cover Headline Should Fuel Be Filtration Centered In for This Cummins Color Box QSK Engines Cummins is a registered trademark of Cummins, Inc. THE CLEANEST FUEL. PERIOD. Treated

More information

EPG Air Cleaners. Durable, Corrosion-Free Air Cleaner Improved Reliability, Superior Engine Protection, Easiest Serviceability

EPG Air Cleaners. Durable, Corrosion-Free Air Cleaner Improved Reliability, Superior Engine Protection, Easiest Serviceability LIGHT DUST AIR CLEANERS Durable, Corrosion-Free Air Cleaner Improved Reliability, Superior Engine Protection, Easiest Serviceability The EPG air cleaner series, which incorporates Donaldson RadialSeal

More information

Intake Accessories On- and Off-Road

Intake Accessories On- and Off-Road Accessories Help You... Set a Filter Service Schedule: Restriction indicators go-no-go, lock-up styles, electric, in-field manometers, safety filter indicator. Product line now includes Filter Minder.

More information

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ZTH WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation

More information

10 Hydraulic Filters

10 Hydraulic Filters 1 Hydraulic Filters Introduction................................... 1-3 HF65 Series................................. 1-9 HF66 Series................................ 1-15 HF67 Series................................

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO

More information

VALVE TIMING DIAGRAM FOR SI ENGINE VALVE TIMING DIAGRAM FOR CI ENGINE

VALVE TIMING DIAGRAM FOR SI ENGINE VALVE TIMING DIAGRAM FOR CI ENGINE VALVE TIMING DIAGRAM FOR SI ENGINE VALVE TIMING DIAGRAM FOR CI ENGINE Page 1 of 13 EFFECT OF VALVE TIMING DIAGRAM ON VOLUMETRIC EFFICIENCY: Qu. 1:Why Inlet valve is closed after the Bottom Dead Centre

More information

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO

More information

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWUH9 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT

INSTALLATION INSTRUCTIONS ISLAND LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS ISLAND LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWEH6-K WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

Crankcase Ventilation Manager (CVM) Installation Instructions

Crankcase Ventilation Manager (CVM) Installation Instructions Crankcase Ventilation Manager (CVM) Installation Instructions CVM280 CVM424 Parts List E D C B A A B C D E Part Description No. Included A Shell 1 B Collar 1 C *O-Ring 1 D *Element 1 E Head 1 Part Number

More information

ProVent MANN+HUMMEL Oil Separator for Closed and Open Crankcase Ventilation

ProVent MANN+HUMMEL Oil Separator for Closed and Open Crankcase Ventilation ProVent MANN+HUMMEL Oil Separator for Closed and Open Crankcase Ventilation ProVent high performance with distinct advantages ProVent is MANN+HUMMEL's newest innovation for crankcase ventilation. It is

More information

MOISTURE MEETS ITS MATCH

MOISTURE MEETS ITS MATCH Donaldson Delivers T.R.A.P. Breather Technology For Hydraulic and Lube Oil Reservoirs MOISTURE MEETS ITS MATCH Donaldson T.R.A.P. breathers collect and expel the moisture out of reservoirs, which means

More information

Cummins Westport The Natural Choice ISL G

Cummins Westport The Natural Choice ISL G Cummins Westport The Natural Choice ISL G The Leading Natural Gas Engine For Truck And Bus. Lower Emissions, Improved Performance, Lower Costs. The ISL G is the natural choice in alternative-fuel engine

More information

EXPERTLY ENGINEERED FULL FLOW OIL FILTERS FOR HEAVY DUTY ENGINES

EXPERTLY ENGINEERED FULL FLOW OIL FILTERS FOR HEAVY DUTY ENGINES EXPERTLY ENGINEERED FULL FLOW OIL FILTERS FOR HEAVY DUTY ENGINES OVER THE PAST FEW YEARS, THERE HAS BEEN A MAJOR MISCONCEPTION REGARDING HEAVY DUTY OIL FILTRATION Mislead by confusing manufacturer warranty

More information

Leadership in Filtration. ENTARON HD Highest application flexibility through innovative evolution

Leadership in Filtration. ENTARON HD Highest application flexibility through innovative evolution Leadership in Filtration ENTARON HD Highest application flexibility through innovative evolution 2 ENTARON HD Compact with excellent application flexibility The ENTARON HD series from MANN+HUMMEL replaces

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO ISLAND RANGE HOOD Read All Instructions Thoroughly Before Beginning

More information

Fume extractor is warranted for two years, parts and labor.

Fume extractor is warranted for two years, parts and labor. Industrial Centralized Systems Issued Feb. 7 Index No. AY/. Welding Safety and Health Quick Specs Industrial Applications Manufacturing and fabrication Schools and training centers Processes Stick (SMAW)

More information

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES WALL MOUNT HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS JCH/C2 DESIGNER SERIES

More information

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

POSITIVE DISPLACEMENT BLOWERS & VACUUM PUMPS. HeliFlow Industrial Series

POSITIVE DISPLACEMENT BLOWERS & VACUUM PUMPS. HeliFlow Industrial Series POSITIVE DISPLACEMENT LOWERS & VACUUM PUMPS HeliFlow Industrial Series It's all about... the HeliFlow The HeliFlow Series integrates proven experience with blower design and manufacturing techniques to

More information

Ultipleat SRT Filters

Ultipleat SRT Filters Lenntech info@lenntech.com www.lenntech.com Tel. +31-15-261.09.00 Fax. +31-15-261.62.89 Ultipleat SRT Filters Stress Resistant Technology The Ultimate in Filter Design Ultipleat SRT Filters Pall s Ultipleat

More information

INTRODUCING. Donaldson Blue Filters with NEW Ultra-Web HD Media BEST THE

INTRODUCING. Donaldson Blue Filters with NEW Ultra-Web HD Media BEST THE INTRODUCING Donaldson Blue Filters with NEW Ultra-Web HD Media THE BEST JUST GOT BETTER DONALDSON BLUE AIR FILTERS WITH Ultra-Web HD Media Calling your work-site dusty is a monumental understatement. Dust

More information

Power Rating Minimum Power 250 bkw 335 BHP Maximum Power 340 bkw 456 BHP

Power Rating Minimum Power 250 bkw 335 BHP Maximum Power 340 bkw 456 BHP The Cat C9.3B Diesel Engine is offered in ratings ranging from 250-340 bkw (335-456 bhp) @ 1800-2200 rpm. These ratings meet U.S. EPA Tier 4 Final and EU Stage V emission standards. The C9.3B engines are

More information

MANN+HUMMEL Piclon High performance two-stage air cleaner with robust metal housing

MANN+HUMMEL Piclon High performance two-stage air cleaner with robust metal housing MANN+HUMMEL Piclon High performance two-stage air cleaner with robust metal housing 9 : Two-stage air cleaner with metal housing The Piclon line from MANN+HUMMEL, with its proven two-stage air cleaners,

More information

Air Cleaners for Medium Dust Conditions F Series & XRB Air Cleaners

Air Cleaners for Medium Dust Conditions F Series & XRB Air Cleaners Powerful Two-Stage Filtration for Diesel Engines Operating in Medium to Heavy Dust Conditions The air cleaners featured in this section offer reliable two-stage filtration designs that have been proven

More information

Section: G Crankcase Filtration

Section: G Crankcase Filtration Section: Crankcase Filtration aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Table of Contents Closed Crankcase Ventilation

More information

Intake Accessories On- and Off-Road

Intake Accessories On- and Off-Road Accessories Help You... Set a Filter Service Schedule: Restriction indicators go-no-go, lock-up styles, electric, in-field manometers, safety filter indicator Aspirate (or scavenge) an intake system: Strata

More information

Introduction Filter Heads Extended Service Interval Filters Standard Service Interval Filters

Introduction Filter Heads Extended Service Interval Filters Standard Service Interval Filters 7 Water Filters Introduction... 7-3 Filter Heads.... 7-6 Extended Service Interval Filters... 7-8 Standard Service Interval Filters.... 7-10 Introduction Water () Filtration Technology The function of

More information

Redefining Efficiency. B6.7 For Truck Applications.

Redefining Efficiency. B6.7 For Truck Applications. Redefining Efficiency. B6.7 For Truck Applications. Redefining Efficiency. When you say the word efficiency to anyone in the trucking industry, the conversation immediately turns to fuel economy for good

More information

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES WALL MOUNT HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS JDH/C2 DESIGNER SERIES

More information

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO WALL MOUNT HOOD WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK C U L R Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS EUROLINE/EUROLINE PRO

More information

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD

INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS CWSH3 WALL MOUNT HOOD Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

EXPERTLY ENGINEERED FULL FLOW OIL FILTERS FOR HEAVY DUTY ENGINES

EXPERTLY ENGINEERED FULL FLOW OIL FILTERS FOR HEAVY DUTY ENGINES G CIN XL DU RO 01 INT 90 LFP EXPERTLY ENGINEERED FULL FLOW OIL FILTERS FOR HEAVY DUTY ENGINES OVER THE PAST FEW YEARS, THERE HAS BEEN A MAJOR MISCONCEPTION REGARDING HEAVY DUTY OIL FILTRATION Misled by

More information

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD

INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS K-SERIES UNDER CABINET HOOD Read All Instructions Thoroughly Before Beginning Installation

More information

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01

Contents. Overview. Safety Instructions. Before Installation. Installation. Operation. Maintenance. Replacement Parts. System Specifications 8 01 PrintPRO Universal Contents Overview 1 01 02 03 Overview of your extraction system (front) Overview of your extraction system (back) Overview of the Control Panel Safety Instructions 2 01 Important safety

More information

Efficiency and Engine Wear. Media Efficiency Comparison. Studies on the ingestion of particulates 10,000 3,000 1,

Efficiency and Engine Wear. Media Efficiency Comparison. Studies on the ingestion of particulates 10,000 3,000 1, AMSOIL Ea Air Filters AMSOIL Ea Air Filters represent a major breakthrough in filtration technology. For the first time, revolutionary nanofiber technology is available to the auto/light truck market.

More information

Full-Flow Lube Oil Filters

Full-Flow Lube Oil Filters Donaldson Delivers Front Cover Headline Should Be Centered In for This Cummins Color Box X15 / ISX Engines Full-Flow Lube Oil Filters Cummins is a registered trademark of Cummins, Inc. PROVEN FULL -FLOW

More information

Engine Liquid Filtration

Engine Liquid Filtration Engine Liquid Filtration Lube/Oil, Fuel, Coolant, Hydraulic and Transmission Since 1915, we have delivered innovative filtration solutions that protect engine components to extend the life of your equipment.

More information

HeliFlow Industrial Series. Positive Displacement Blowers & Vacuum Pumps

HeliFlow Industrial Series. Positive Displacement Blowers & Vacuum Pumps HeliFlow Industrial Series Positive Displacement Blowers & Vacuum Pumps 2008 2 GD HeliFlow Built By the Industry Leaders Gardner Denver Tradition Quality Innovation Results GD HeliFlow HeliFlow integrates

More information

INTRODUCING. Front Cover Headline. HD Media BEST THE. Cummins is a registered trademark of Cummins, Inc.

INTRODUCING. Front Cover Headline. HD Media BEST THE. Cummins is a registered trademark of Cummins, Inc. INTRODUCING Front Cover Headline Should Donaldson Be Centered Blue Filters with In NEW This Ultra-Web Color Box HD Media BEST THE JUST GOTBETTER Cummins is a registered trademark of Cummins, Inc. DONALDSON

More information

DONALDSON DELIVERS A single source for on-road engine filtration

DONALDSON DELIVERS A single source for on-road engine filtration DONALDSON DELIVERS A single source for on-road engine filtration Durable, rugged and built for the long haul, Donaldson replacement filters are manufactured to the same quality standards as the original.

More information

Diesel Power. Advanced synthetic technology to protect today s most demanding diesels. SYNTHETIC DIESEL OILS. FuEL.

Diesel Power. Advanced synthetic technology to protect today s most demanding diesels. SYNTHETIC DIESEL OILS. FuEL. Diesel Power SYNTHETIC DIESEL OILS DrIvETraIN FLuIDS FuEL additives Advanced synthetic technology to protect today s most demanding diesels. Synthetic Diesel Oils AMSOIL introduced the world s first synthetic

More information

CAUTION: NOT INTENDED FOR STREET USE HOW TO USE THIS CATALOG WE LOVE RACING

CAUTION: NOT INTENDED FOR STREET USE HOW TO USE THIS CATALOG WE LOVE RACING WE LOVE RACING When WIX Filters began making its performancedriven products in 1939, the first Daytona race was still 20 years down the road. In developing the WIX Racing line, WIX engineers have worked

More information

Engine Air Cleaners, Intake Accessories & Service Parts

Engine Air Cleaners, Intake Accessories & Service Parts Donaldson filters are built to provide the best protection for your engine - even in the most demanding operating environments. Engine Air Cleaners, Intake Accessories & Service Parts Table of Contents

More information

PACKAGED DOWNFLO EVOLUTION DUST COLLECTORS. The Complete Plug-and-Play Solution

PACKAGED DOWNFLO EVOLUTION DUST COLLECTORS. The Complete Plug-and-Play Solution PACKAGED DOWNFLO EVOLUTION DUST COLLECTORS The Complete Plug-and-Play Solution WE KNOW FILTRATION Donaldson is a global provider of filtration solutions for manufacturing industries. Our advanced technology,

More information

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT

INSTALLATION INSTRUCTIONS K SERIES LINER INSERT Read and Save These Instructions All Hoods Must Be Installed By A Qualified Installer INSTALLATION INSTRUCTIONS K SERIES LINER INSERT Read All Instructions Thoroughly Before Beginning Installation WARNING

More information

About Pre-Separators. When a Pre-Separator is to be used the following should be considered: Pre-Separators should be used: Dustcontrol Pre-Separators

About Pre-Separators. When a Pre-Separator is to be used the following should be considered: Pre-Separators should be used: Dustcontrol Pre-Separators Pre-Separators When large quantities of material are to be separated, it is advisable to use a pre-separator. The pre-separator can be placed at the workplace or in conjunction with the central unit. 49

More information

CYLINDRICAL ROLLER BEARING CATALOG TIMKEN SMALL BORE METRIC SEALS CATALOG

CYLINDRICAL ROLLER BEARING CATALOG TIMKEN SMALL BORE METRIC SEALS CATALOG CYLINDRICAL ROLLER BEARING CATALOG ABOUT THE TIMKEN COMPANY The leading authority on tapered roller bearings, Timken today applies its deep knowledge of metallurgy, tribology and mechanical power transmission

More information

Redefining Efficiency B6.7 For Truck Applications.

Redefining Efficiency B6.7 For Truck Applications. Redefining Efficiency. 2017 B6.7 For Truck Applications. Redefining Efficiency. When you say the word efficiency to anyone in the trucking industry, the conversation immediately turns to fuel economy for

More information

Industry Shaping Technology Air Filtration Trends and Evolution

Industry Shaping Technology Air Filtration Trends and Evolution Industry Shaping Technology Air Filtration Trends and Evolution Air Filtration System Trends Smaller Air Cleaner Systems Over the past decade numerous emission standards and engineering achievements have

More information

F-250/550 Power Stroke Diesel Maintenance Intervals

F-250/550 Power Stroke Diesel Maintenance Intervals F-250/550 Power Stroke Diesel Maintenance Intervals Power Stroke Diesel engines and Super Duty pickups are used in a large variety of demanding applications. Their owners put them through their paces and

More information

Minimum Power 224 bkw 300 bhp Maximum Power 298 bkw 400 bhp

Minimum Power 224 bkw 300 bhp Maximum Power 298 bkw 400 bhp Specifications Power Rating The Cat C9.3 ACERT Diesel Engine is offered in ratings ranging from 224-298 bkw (300-400 bhp) @ 1800-2200 rpm. These ratings meet U.S. EPA Tier 4 Final, EU Stage IV emission

More information

1204F-E44TTA Industrial Diesel Engine

1204F-E44TTA Industrial Diesel Engine The Perkins 1204F, the 4 cylinder option for the 1200 Series, gives you a complete power solution that meets the latest EU Stage IV/U.S. EPA Tier 4 Final emission standards. The choice of options, engine

More information

FOR HEAVY DUTY APPLICATIONS

FOR HEAVY DUTY APPLICATIONS Air and Oil Filters FOR HEAVY DUTY APPLICATIONS With Nanofiber Technology Ideal For Extended Maintenance Intervals Superior In Prolonging Equipment Life Extended service filters Increase engine protection

More information