Type TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION

Size: px
Start display at page:

Download "Type TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION"

Transcription

1 Homepage > Prodotti > Elementi ed unità filtranti > Cassonetti terminali per l'alloggiamento di filtri a piccole pieghe > Terminali filtranti per camere bianche > Type TFP Type TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION Pharmaceutical clean room terminal filters as final filter stage with Mini Pleat filter panels for the separation of suspended particles. Used in highly sensitive areas in pharmaceuticals, medicine, and biology Mini Pleat filter panels with downstream fluid seals meet the highest hygiene requirements Easy, time-saving, and secure filter change Diffuser face is held in place by magnets and can be hinged down to facilitate cleaning and validation; filter change without tool Robust, welded construction Compact construction, suitable for low ceilings Various diffuser face plates to ideally meet individual requirements Horizontal or vertical connection Removable spigot for installation into closed ceilings in case of horizontal connection For air cleanliness classes 5 to 8 according to ISO 16-1 Meets the hygiene requirements of VDI 6022

2 APPLICATION Application Pharmaceutical clean room terminal filter type TFP for ceiling installation as final filter stage and for air distribution in sensitive areas of the pharmaceutical industry Fitting of filter elements for the separation of suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply or extract air Special characteristics Compact construction Flush ceiling installation Removable spigot for installation into closed ceilings Diffuser face plate can be hinged down Nominal sizes [mm] 00, 500, 600, 625 DESCRIPTION Variants TC: Top entry circular spigot SC: Side entry circular spigot SCR: Side entry circular spigot, removable Construction Sheet steel, powder-coated RAL 9010, pure white Attachments FD: Ceiling swirl diffuser TDF: Ceiling swirl diffuser Useful additions

3 Mini Pleat filter panels (MFP) Suitable filter elements to be ordered separately Construction features Welded filter casing with sealing frame for fitting filter elements, with a seal on the downstream side Mounted pressure measurement points to monitor the operating differential pressure and with internal measuring tube Materials and surfaces Casing and diffuser face plate made of sheet steel, powder-coated RAL 9010, pure white Standards and guidelines Hygiene meets the requirements of VDI 6022, VDI 3803, DIN 196 Part, ÖNORM H 6021 and ÖNORM H 6020, SWKI VA and SWKI 99-3, and EN Maintenance Diffuser face plate can be hinged down to facilitate disassembly and cleaning Particulate filter need not be removed for cleaning (seal on downstream side) Easy change of filter elements due to special frame profile; no additional fluid sealing frame is necessary TECHNISCHE INFORMATION Function, Specification text, Order code, Related products FUNCTION

4

5 SPECIFICATION TEXT Pharmaceutical clean room terminal filter type TFP for ceiling installation as final filter stage and for air distribution in sensitive areas of the pharmaceutical industry. Fitting of filter elements for the separation of suspended particles such as aerosols, toxic dusts, viruses and bacteria from the supply or extract air. Welded filter casing with sealing frame for fixing the Mini Pleat filter panels, with a fluid seal on the downstream side. With top entry or side entry spigot; removable spigot as an option. The Mini Pleat filter panels are pressed into place using a tensioning frame with knurled screws. Casing with mounted pressure measurement points to monitor the operating differential pressure and with internal measuring tube. Diffuser face plate made of sheet steel, powder-coated (RAL 9010), types FD and TDF; can be hinged down to facilitate disassembly and cleaning. Leakage test for each casing. Special characteristics Compact construction Flush ceiling installation Removable spigot for installation into closed ceilings Diffuser face plate can be hinged down Materials and surfaces Casing and diffuser face plate made of sheet steel, powder-coated RAL 9010, pure white Construction Sheet steel, powder-coated RAL 9010, pure white

6 ORDER CODE Variants, Dimensions and weight, Product details

7 Homepage > Prodotti > Elementi ed unità filtranti > Cassonetti terminali per l'alloggiamento di filtri a piccole pieghe > Terminali filtranti per camere bianche > Type TFP VARIANTS TFP-TC Gehäuse mit rundem Anschlussstutzen Anschlussstutzen oben angeordnet TFP-SC Gehäuse mit rundem Anschlussstutzen Anschlussstutzen seitlich angeordnet TFP-SCR Gehäuse mit rundem Anschlussstutzen Anschlussstutzen seitlich angeordnet Anschlussstutzen demontierbar DIMENSIONS AND WEIGHT Alle Gewichtsangaben sind netto, ohne Verpackung Filtergröße B H T K M J L kg Außenmaß Luftdurchlass Außenmaß Gehäuse 5 Außenmaß Gehäuseflansch 6 Lochabstand Aufhängung oben 7 Gewicht (ca.) Home Contatto Stampa Condizioni generali di vendita e consegna Privacy Disclaimer 26/01/2018 TROX Italia S.p.A.

8 Homepage > Prodotti > Elementi ed unità filtranti > Cassonetti terminali per l'alloggiamento di filtri a piccole pieghe > Terminali filtranti per camere bianche > Type TFP Filtergröße B H T K M J L G kg Außenmaß Luftdurchlass Außenmaß Gehäuse 5 Außenmaß Gehäuseflansch 6 Lochabstand Aufhängung oben 7 Anschlussmaß bis Stutzenmitte 8 Gewicht (ca.) Filtergröße B H T K M J L G kg Außenmaß Luftdurchlass Außenmaß Gehäuse 5 Außenmaß Gehäuseflansch 6 Lochabstand Aufhängung oben 7 Anschlussmaß bis Stutzenmitte 8 Gewicht (ca.) Installation details, Basic information and nomenclature Home Contatto Stampa Condizioni generali di vendita e consegna Privacy Disclaimer 26/01/2018 TROX Italia S.p.A.

9 Homepage > Prodotti > Elementi ed unità filtranti > Cassonetti terminali per l'alloggiamento di filtri a piccole pieghe > Terminali filtranti per camere bianche > Type TFP INSTALLATION DETAILS Installation and commissioning Fitting of filter elements with a fluid seal on the downstream side The filter element is pressed into place using a tensioning frame with knurled screws Diffuser face plate is hinged and held in place by magnets; no additional tools required TROX Italia S.p.A. Online-Services Service-Hotlines TROX Academy Your contact partner Online fault report Telefono Telefax Via Mecenate Milano ITALY Home Contatto Stampa Condizioni generali di vendita e consegna Privacy Disclaimer 26/01/2018 TROX Italia S.p.A.

Home > Products > Filter elements and filter units > Particulate filter air terminal devices > Pharmaceutical clean room terminal filters > Type TFP

Home > Products > Filter elements and filter units > Particulate filter air terminal devices > Pharmaceutical clean room terminal filters > Type TFP Type TFP FOR CRITICAL AIR CLEANLINESS AND VERY CRITICAL HYGIENE REQUIREMENTS, SUITABLE FOR CEILING INSTALLATION Pharmaceutical clean room terminal filters as final filter stage with Mini Pleat filter panels

More information

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES Prefilters or final filters for the separation of fine dust, or particulate filters for the most critical requirements in ventilation systems Filter

More information

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the extract air control in buildings with variable air volume systems and demanding acoustic requirements Highly

More information

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400

RN-S: 80, 100, 125 RN: 80, 100, 125, 160, 200, 250, 315, 400 RN-FL: 100, 125, 160, 200, 250, 315, 400 Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES Circular self-powered volume flow controllers for the control of supply air or extract air in constant air volume systems Volume flow rate

More information

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements

Type TVZ. VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Type TVZ FOR SUPPLY AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Highly

More information

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES

Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES Type MFI COMPACT CONSTRUCTION FOR LARGE VOLUME FLOW RATES Prefilters or final filters for the separation of fine dust, or particulate filters for the most critical requirements in ventilation systems Filter

More information

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS

Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS Home > PRODOTTI > Unità di regolazione > VARYCONTROL > Unità terminali VAV > Serie TVA Type TVA FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the extract air control

More information

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES

Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES Circular VAV terminal units for standard applications regarding the supply air or extract air control in variable air

More information

Type VSD35. Nominal length up to 1500 mm: one spigot

Type VSD35. Nominal length up to 1500 mm: one spigot Type VSD35 Nominal length up to 1500 mm: one spigot NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with 35 mm diffuser face (nominal width) and adjustable air control elements

More information

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES

Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES Homepage > Products > Air Diffusers > Industrial diffusers > Diffusers for high momentum > Type ISH Type ISH FOR INDUSTRIAL ZONES WITHOUT AIR POLLUTING PROCESSES Impulse diffusers with horizontal air discharge

More information

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL

Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES. Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Homepage > Products > Air Diffusers > Swirl diffusers > Type VDL Type VDL FOR HIGH ROOMS, WITH ADJUSTABLE AIR CONTROL BLADES Circular ceiling swirl diffusers, with manual or motorised adjustment of the

More information

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES Homepage > Products > Grilles and Diffusers > Ceiling diffusers > Ceiling swirl diffusers with perforated face plate > Type DCS Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION

More information

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF

Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF Type TVT FOR NORMAL AND HIGH VOLUME FLOW RATE RANGES AND LOW-LEAKAGE SHUT-OFF Rectangular VAV terminal units for standard applications regarding the supply air or extract air control in variable air volume

More information

Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN.

Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN. Homepage > Prodotti > Unità di regolazione > Regolazione di flussi costanti CONSTANTFLOW > KVS- Regolatore di portata > Serie EN Type EN FOR THE PRECISE CONTROL OF NORMAL AND HIGH CONSTANT VOLUME FLOWS

More information

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1 X X testregistrierung Disc valves Type For supply air Circular disc valves with manually adjustable annular gap Nominal sizes 100, 125, 160, 200 mm Volume flow rate range 10 90 l/s or 36 324 m³/h Diffuser

More information

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK

Type AK FOR LOW-LEAKAGE SHUT-OFF. Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK Type AK FOR LOW-LEAKAGE SHUT-OFF Circular shut-off dampers for shutting off volume flows in ventilation ducts

More information

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES Circular self-powered volume flow controllers for the control of supply air or extract air in constant air volume systems Volume flow rate

More information

HEPA terminal filter units Ceiling diffusers: F640, F650, F654, F655, F656, F659, F660 Wall grilles: F670

HEPA terminal filter units Ceiling diffusers: F640, F650, F654, F655, F656, F659, F660 Wall grilles: F670 HPA terminal filter units eiling diffusers: 60, 650, 65, 655, 656, 659, 660 Wall grilles: 670 or critical air purity and hygiene requirements Used in medicine, biology, pharmaceuticals, and sensitive technical

More information

Parts and characteristics

Parts and characteristics Type TVZ FOR SUPPLY AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS VAV terminal units for the supply air control in buildings with variable air volume systems and demanding acoustic requirements Highly

More information

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW

Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES. Homepage > Products > Control units > Constant volume flow control CONSTANTFLOW Type RN FOR THE PRECISE CONTROL OF CONSTANT VOLUME FLOW RATES Circular self-powered volume flow controllers for the control of supply air or extract air in constant air volume systems Volume flow rate

More information

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades X X testregistrierung Type Vertical air discharge Horizontal air discharge For large temperature differences in heating mode, high penetration of air, with adjustable air control blades Circular ceiling

More information

Ducted HEPA filter units for highly sensitive areas

Ducted HEPA filter units for highly sensitive areas Ducted HEPA filter units for highly sensitive areas Without prefilter casing: Type F60 With prefilter casing: Type F70 Duct casing for installation into ductwork, with or without prefilter Double-groove

More information

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK

Type AKK FOR CONTAMINATED AIR. Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK Homepage > Products > Airflow Control - VAV and CAV > Shut-off and restriction > Shut-Off Devices > Type AKK Type AKK FOR CONTAMINATED AIR Plastic circular shut-off dampers for shutting off aggressive

More information

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Rectangular VAV terminal units for the extract air control in buildings with variable air volume

More information

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge Diffuser face plate with perforated circular face style and exposed discharge nozzle Diffuser

More information

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Homepage > Products > Control units > Shut-off and restriction > Shut-Off Devices > Type AK-Ex Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX) Circular shut-off

More information

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE Homepage > Products > Sound attenuators > Splitter sound attenuators > Type MSA Type MSA Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

More information

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS

PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Homepage > Producten > Luchtroosters > Lijnroosters > Pureline18 PURELINE18 PARTICULARLY SLIM DIFFUSER FACE, AVAILABLE IN NUMEROUS VARIANTS FOR MANY DIFFERENT INSTALLATION SITUATIONS Slot diffusers with

More information

Ceiling swirl diffusers with perforated face plate

Ceiling swirl diffusers with perforated face plate X X testregistrierung Ceiling swirl diffusers with perforated face plate Type Horizontal swirling air discharge For horizontal swirling supply air discharge creating high induction levels, with fixed air

More information

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES

Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Type TA-Silenzio FOR EXTRACT AIR SYSTEMS WITH DEMANDING ACOUSTIC REQUIREMENTS AND LOW AIRFLOW VELOCITIES Rectangular VAV terminal units for the extract air control in buildings with variable air volume

More information

Type NAK. Gas-tight shut-off damper with pneumatic actuator

Type NAK. Gas-tight shut-off damper with pneumatic actuator Homepage > Products > Control units > Shut-Off dampers > Type NAK Type NAK FOR THE GAS-TIGHT SHUT-OFF OF DUCTS Gas-tight shut-off damper with pneumatic actuator Gas-tight shut-off dampers are designed

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type RFD-Sirius, cross bar Horizontal swirling air discharge Circular diffuser face, integral measuring tubes is an air terminal device combined with a VAV

More information

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX Type TX FOR THE REDUCTION OF AIR-REGENERATED NOISE OF AIR TERMINAL UNITS TYPE TVJ, OR EN Rectangular secondary silencers

More information

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU

Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Homepage > Products > Fire and Smoke Protection > Fire dampers > Type KA-EU Type KA-EU FOR THE EXTRACT AIR OF COMMERCIAL KITCHENS Rectangular fire damper for use in extract air and exhaust air ducts of

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Adjustable blades Protective cage For high rooms, with adjustable air control blades Circular ceiling swirl diffusers,

More information

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION

Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION Homepage > Products > Sound attenuators > Circular silencers > Type CS Type CS FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, ALUMINIUM CONSTRUCTION Circular silencers, in rigid aluminium construction,

More information

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL.

Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL. Homepage > Products > External louvres - louvre blades > Mechanically self-powered dampers > Non-return dampers > Type KUL Type KUL FOR INSTALLATION INTO DUCTWORK Non-return dampers prevent unwanted airflows

More information

Ceiling swirl diffusers

Ceiling swirl diffusers X X testregistrierung Ceiling swirl diffusers Type Horizontal swirling air discharge Vertical air discharge Protective cage For high rooms, with adjustable air control blades Square ceiling swirl diffusers,

More information

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX

Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX. Type TX Homepage > Products > Control units > VARYCONTROL > Secondary silencer > Type TX Type TX FOR THE REDUCTION OF AIR-REGENERATED NOISE OF AIR TERMINAL UNITS TYPE TVJ, OR EN Rectangular secondary silencers

More information

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS

Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS Homepage > Products > External Louvres & Dampers > Multileaf dampers > Multileaf dampers > Type JZ Low leakage Type JZ Low leakage FOR LOW-LEAKAGE SHUT-OFF IN AIR CONDITIONING SYSTEMS Rectangular multileaf

More information

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM MULTI-SERVICE ACTIVE CHILLED BEAM WITH TWO-WAY AIR DISCHARGE AND HORIZONTAL

More information

Multileaf damper with actuator

Multileaf damper with actuator JZ Multileaf damper with actuator FOR SHUTTING OFF THE AIRFLOW IN AIR CONDITIONING SYSTEMS Rectangular multileaf dampers for volume flow and pressure control as well as for shutting off ducts and openings

More information

Shut-off dampers. Type AKK. For contaminated air PD AKK 1

Shut-off dampers. Type AKK. For contaminated air PD AKK 1 X X testregistrierung Shut-off dampers Type Variant with circular spigot For contaminated air Plastic circular shut-off dampers for shutting off aggressive media volume flows in air conditioning systems

More information

VAV terminal units. Type TVM. For dual duct systems PD TVM 1

VAV terminal units. Type TVM. For dual duct systems PD TVM 1 X X testregistrierung VAV terminal units Type Variant -S Rectangular connection on the room end For dual duct systems VAV dual duct terminal units for dual duct systems with variable volume flows in buildings

More information

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1 X X testregistrierung CAV controllers Type Adjustment scale ATEX-Zertifizierung For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) Circular, mechanical self-powered

More information

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or extract air in constant air

More information

Slot diffusers for ceiling installation

Slot diffusers for ceiling installation X X testregistrierung Slot diffusers for ceiling installation Type lenum box with damper blade (optional) Alternating horizontal air discharge Concealed screw fixing With wide diffuser face for larger

More information

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES

Type WG. External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS, AVAILABLE ALSO IN LARGE SIZES Homepage > Products > External Louvres & Dampers > External weather louvres > External weather louvres > Type WG Type WG External weather louvre made of galvanised steel sections FOR THE MOST DIVERSE APPLICATIONS,

More information

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR

Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR. Type TVR Homepage > Products > Control units > VARYCONTROL > VAV TERMINAL UNITS > Type TVR Type TVR FOR THE MOST DIVERSE APPLICATIONS REGARDING STANDARD VOLUME FLOW RATE RANGES Circular VAV terminal units for standard

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Grille cores made of aluminium, with fixed horizontal blades Grille cores with special profiled blades

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of aluminium, with fixed horizontal blades also for horizontal runs Single

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles with flat border construction also for continuous horizontal runs The new ventilation

More information

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS

Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS Homepage > Products > Control Systems > Variable volume flow control > VAV terminal units > Type TVLK Type TVLK OPTIMISED FOR USE IN LABORATORIES AND ON FUME CUPBOARDS Plastic circular VAV terminal units

More information

Particle Filter Box FKU

Particle Filter Box FKU Particle Filter Box FKU Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

CONSTANTFLOW Volume Flow Controllers

CONSTANTFLOW Volume Flow Controllers 5/9.1/EN/8 CONSTANTFLOW Volume Flow Controllers for constant volume systems Type EN The art of handling air Contents Description Description 2 Application 3 Construction Dimensions Accessories 4 Dimensions

More information

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1. X X testregistrierung Shut-off dampers Type ATEX-compliant parts and units For low-leakage shut-off of volume flows in potentially explosive atmospheres (ATEX) Circular shut-off dampers for shutting off

More information

Ventilation grilles for installation into walls, sills or rectangular

Ventilation grilles for installation into walls, sills or rectangular X X testregistrierung Ventilation grilles for installation into walls, sills or rectangular ducts Type Ventilation grilles, made of sheet steel, with individually adjustable, horizontal blades Ventilation

More information

CAV controllers Type RN

CAV controllers Type RN 2.1 X X testregistrierung CAV controllers Type For the precise control of constant volume flow rates Circular self-powered volume flow controllers for the control of supply air or return air in constant

More information

TYPE EK-EU SMOKE CONTROL DAMPER

TYPE EK-EU SMOKE CONTROL DAMPER Homepage > PRODUCTS > Fire and Smoke Protection > Smoke Control Damper > Type EK-EU TYPE EK-EU SMOKE CONTROL DAMPER WITH TROXNETCOM AS AN OPTION CE COMPLIANT ACCORDING TO EUROPEAN REGULATIONS EK-EU WITH

More information

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1

VAV terminal units. Type TVZ. For supply air systems with demanding acoustic requirements PD TVZ 1 X X testregistrierung VAV terminal units Type Easy controller Compact controller Rectangular connection on the room end Circular connection on the fan end For supply air systems with demanding acoustic

More information

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic T.3//EN/ Floor diffusers Type FB In aluminium and plastic The art of handling air Contents Description Description Installation examples 3 Construction Dimensions Plenum box Load capacity Installation

More information

Volume Flow Limiters Type VFL

Volume Flow Limiters Type VFL X X Volume Flow Limiters Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical self-powered

More information

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION Hoepage > Products > Sound attenuators > Circular silencers > Type CA Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION Circular silencers Type CA for the reduction

More information

Type Pneumatic actuators

Type Pneumatic actuators Homepage > Products > External louvres - louvre blades > Multileaf dampers > Attachments > Type Pneumatic actuators Type Pneumatic actuators PNEUMATIC ACTUATORS FOR THE OPENING AND CLOSING OF DAMPERS IN

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K .1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element

Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. HEPA filter air outlet with pull-down outlet element Cleanroom systems Puri-Drall PDK. Puri-Clean PCK. Puri-Inlet PEK. with pull-down outlet element DS 4178 E 01.201 Preliminary remarks Materials and designs As a rule, turbulent mixing ventilation is used

More information

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1 X X testregistrierung CAV controllers Type Aerodynamic damper blade Sticker showing volume flow rates Set the volume flow rate Insert Volume flow limiter for insertion into ducting Circular, mechanical

More information

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K

VAV terminal units. Type TVA. For extract air systems with demanding acoustic requi rements K . X X testregistrierung VAV terminal units Type Easy controller Compact controller Circular connection on the fan end For extract air systems with demanding acoustic requi rements VAV terminal units for

More information

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/ 6/5/EN/6 Circular Silencer Rigid and flexible construction Type CA CB CF CS TROX GmbH Telephone +49/28 45/2 02-0 Telefax +49/28 45/2 02-2 65 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn

More information

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en

Circular silencers. Type CS. For the reduction of noise in circular ducts, aluminium construction PD CS 1. 02/2017 DE/en X X testregistrierung Circular silencers Type For the reduction of noise in circular ducts, aluminium construction Circular silencers, in rigid aluminium construction, for the reduction of noise in the

More information

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m

2/18/EN/2. Air Handling Lights. Type LR. Recommended for use in rooms with ceiling heights of approx m 2/18/EN/2 Air Handling Lights Type LR Recommended for use in rooms with ceiling heights of approx. 2.60... 4.00 m Contents Description Description... 2 Supply Air Construction LR-Z... 3 Extract Air Construction

More information

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face

2/1/EN/3. Slot Diffuser. Type VSD15. with 15 mm wide diffuser face 2/1/EN/3 Slot Diffuser Type VSD15 with 15 mm wide diffuser face Contents Air Diffuser Discharge Characteristics (horizontal) 2 Description 3 Air Diffuser Discharge Characteristics (alternating) 3 Construction

More information

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1

Circular silencers. Type CA. For the reduction of noise in circular ducts, galvanised sheet steel construction. 02/2017 DE/en PD CA 1 X X testregistrierung Circular silencers Type For the reduction of noise in circular ducts, galvanised sheet steel construction Circular silencers Type for the reduction of noise in the circular ducts

More information

Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION

Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION Hoepage > Products > Sound attenuators > Circular silencers > Type CF Type CF FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, FLEXIBLE ALUMINIUM CONSTRUCTION Circular silencers, in flexible aluiniu construction,

More information

Type Pneumatic actuators

Type Pneumatic actuators Homepage > Products > External Louvres & Dampers > Multileaf dampers > Attachments > Type Pneumatic actuators Type Pneumatic actuators PNEUMATIC ACTUATORS FOR THE OPENING AND CLOSING OF DAMPERS IN AIR

More information

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION

Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET STEEL CONSTRUCTION Hoepage > Products > Airflow Control - VAV and CAV > Variable air volue flow control - VARYCONTROL > Secondary silencer > Type CA Type CA FOR THE REDUCTION OF NOISE IN CIRCULAR DUCTS, GALVANISED SHEET

More information

ceiling swirl diffuser DQJ

ceiling swirl diffuser DQJ ceiling swirl diffuser DQJ Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Advantages...

More information

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust 2 BERNER INTERNATIONAL Claire total At a glance CLAIRE TOTAL PRO CHEMISTRY Protection Shield The multiple award-winning Shield

More information

Particle Filter Box Model FKF

Particle Filter Box Model FKF Particle Filter Box Model FKF Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de Contents Description...3 Construction...

More information

Pressure relief dampers

Pressure relief dampers X X testregistrierung Pressure relief dampers Type Closed blade For the prevention of excess pressure in rooms Pressure relief dampers for gas fire extinguishing systems and transformer substations Air

More information

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) X X testregistrierung CAV controllers Type Adjustment scale For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX) Rectangular, mechanical self-powered

More information

A CLEAN AIR WORLD. Rigid, gas tight, shock and vibration resistant. Operating pressure guaranteed to ± 8000 Pa. Functional design, userfriendly

A CLEAN AIR WORLD. Rigid, gas tight, shock and vibration resistant. Operating pressure guaranteed to ± 8000 Pa. Functional design, userfriendly S C Gas tight housings for contamination-free filter change Rigid, gas tight, shock and vibration resistant Operating pressure guaranteed to ± 8000 Pa Functional design, userfriendly operation Self-adjusting

More information

N O V E L T Y Diffuser with particulate filter class H13

N O V E L T Y Diffuser with particulate filter class H13 N O V E L T Y Diffuser with particulate filter class H13 NAF Atest Higieniczny: HK/B/1121/02/2007 NAF diffusers are intended to use in low- and mediumpressure ventilation systems. They are used in facilities

More information

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1

CAV controllers. Type EN. For the precise control of normal and high constant volume flows. 01/2017 DE/en PD EN 1 X X testregistrierung CAV controllers Type For the precise control of normal and high constant volume flows Rectangular self-powered volume flow controllers for the control of supply air or extract air

More information

Apartment ventilation

Apartment ventilation GB1250 04.18 AuraFlex LØV-R Apartment ventilation Diffusers in steel Customer adapted diffuser pattern Available in all colours Plenum box with damper and measuring outlet for commissioning Plenum box

More information

JG, JK, JP Ultrafilter

JG, JK, JP Ultrafilter JG, JK, JP Ultrafilter High Efficiency Cylindrical Air Filters Compact space saving design Simple to install Low pressure drops Large filter medium area gives long life service Individually tested and

More information

Duct filter units. Duct HEPA filter units AKF

Duct filter units. Duct HEPA filter units AKF Duct HEPA filter units AKF Application Duct HEPA filter unit AKF is being used in the network of inlet and outlet ducts used to supply or extract air from the rooms with highest demands regarding air cleanness.

More information

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en X X testregistrierung Heat exchanger Type For the reheating of airflows in circular ducting Circular hot water heat exchanger for the reheating of airflows, suitable for VAV terminal units Type TVR and

More information

Displacement flow diffusers. L e

Displacement flow diffusers. L e Displacement flow diffusers L-08-1-04e Contents Application Safety instructions Contents Application Safety instructions 2 Construction Perforation Principle of operation Example of quick selection 3 Type

More information

HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION. Exflow 28 Technical Specification. Page 1 of 7

HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION. Exflow 28 Technical Specification. Page 1 of 7 HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION Exflow 28 Technical Specification Page 1 of 7 TECHNICAL SUMMARY Terminal Unit size 12-3 ¼ x 12-3 ¼ x 23 ¾ Terminal Unit weight 3527

More information

TROX Prisliste Filtrering K7-00

TROX Prisliste Filtrering K7-00 TROX Prisliste 2019 Filtrering K7-00 K1 - ARMATURER, RISTE Ceiling swirl diffusers AIRNAMIC...7 VDW...8 TDV-SilentAIR...9 RFD...10 FD...11 TDF-SilentAIR...12 VD...13 VDL...14 FDE...16 Design ceiling swirl

More information

Air terminal devices

Air terminal devices Installation manual GB/en Air terminal devices Slot Diffusers Type PureLine18 TROX GmbH Heinrich-Trox-Platz 47504 Neukirchen-Vluyn Germany Phone: +49 (0) 2845 2020 Fax: +49 (0) 2845 202265 E-mail: trox@trox.de

More information

Ceiling Swirl Diffuser DQJ

Ceiling Swirl Diffuser DQJ Ceiling Swirl Diffuser DQJ Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telephone +49 (0) 74 63-980 - 0 Fax +49 (0) 74 63-980 - 200 info@schako.de www.schako.de contents Description...3 Advantages...

More information

Homepage > Products > External Louvres & Dampers > Multileaf dampers > Attachments > Type Explosion-proof actuators. Type Explosion-proof actuators

Homepage > Products > External Louvres & Dampers > Multileaf dampers > Attachments > Type Explosion-proof actuators. Type Explosion-proof actuators Homepage > Products > External Louvres & Dampers > Multileaf dampers > Attachments > Type Explosion-proof actuators Type Explosion-proof actuators FOR OPENING AND CLOSING MULTILEAF DAMPERS INSTALLED IN

More information

Maximum Protection in Filter Systems CGF/CGG. GEA Ceiling Air Outlets Data & Facts. GEA Heat Exchangers / GEA Air Treatment

Maximum Protection in Filter Systems CGF/CGG. GEA Ceiling Air Outlets Data & Facts. GEA Heat Exchangers / GEA Air Treatment Maximum Protection in Filter Systems CGF/CGG GEA Ceiling Air Outlets Data & Facts GEA Heat Exchangers / GEA Air Treatment Table of Contents Technical Description... 3 Application and Components... 3 Components...

More information

Lint separator FLARE

Lint separator FLARE Lint separator FLARE Ferdinand Schad KG Steigstraße 25-27 D-78600 Kolbingen Telefon 0 74 63-980 - 0 Telefax 0 74 63-980 - 200 info@schako.de www.schako.de Contens Description...3 Construction... 3 Model...

More information

COMPETENCE BROCHURE Filter Media DELBAG HEPA Filter. Fresh Air Freed of Floating Materials

COMPETENCE BROCHURE Filter Media DELBAG HEPA Filter. Fresh Air Freed of Floating Materials COMPETENCE BROCHURE Filter Media DELBAG HEPA Filter Fresh Air Freed of Floating Materials DELBAG HEPA FILTER From Universal to Specifically Technology which Liberates... FILTER WITH INNOVATION In the pharmaceutical

More information

Apartment ventilation

Apartment ventilation GB1250 06.18 AuraFlex LØV-R Apartment ventilation Diffusers in steel Customer adapted diffuser pattern Available in all colours Plenum box with damper and measuring outlet for commissioning Plenum box

More information

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS Square extract air diffuser QUICK FACTS Perforated air diffuser front face Manages large extract airflows Flush design Designed for modular suspended ceilings Quick Access front face Can be combined with

More information

Active Chilled Beams

Active Chilled Beams T 2.4/3/EN/1 Active Chilled Beams Type DID00B TROX GmbH Telephone +49/2 45/2 02-0 Telefax +49/2 45/202-25 Heinrich-Trox-Platz e-mail trox@trox.de D-47504 Neukirchen-Vluyn www.troxtechnik.com Contents Description

More information