AP LP LW YP YP-DU Series

Size: px
Start display at page:

Download "AP LP LW YP YP-DU Series"

Transcription

1 AP LP LW YP YP-DU Series FEATURES > > Oil-less > > Long life > > Low power consumption > > Worldwide service network > > Low sound level/vibration > > Protection class IP54 (AP/LP/LW-Series) > > CE approved (23V 5Hz models with housing and cord with plug) > > Integrated intake filter (AP/LP/LW-Series) > > RoHS compliant BASE MODEL AP LP LW YP YP-DU TYPICAL APPLICATIONS > > Sewage aeration > > Aquarium aeration > > Gas/particle analysis > > Air mattress > > Compression therapy > > Battery aeration > > Grey water treatment > > Process water recycling Linear

2 Linear Diaphragm Pumps PRODUCT OVERVIEW Model Pressure Vacuum without housing with housing (l/min) Page YP-15DU YP-2DU 15 1 mbar 2 1 mbar 3 YP-15A YP-2A 15 1 mbar 2 1 mbar 4 YP-2V 2 (18) 1 (-1) mbar 5 YP-4DU YP-5DU mbar 5 12 mbar 6 YP-4VC YP-5VC YP-6VC YP-7VC 43 (39) 12 (-12) mbar 58 (52) 12 (-12) mbar 66 (61) 12 (-12) mbar 73 (64) 12 (-18) mbar 7 AP-4 AP-6N AP-6/8 AP-8H AP-1 AP mbar 47 2 mbar 6 2 mbar 82 2 mbar 18 2 mbar mbar 8,9 LP-15HN LP-2HN 15 2 mbar 2 2 mbar 1 LW-24 LW-3 LW mbar 35 2 mbar mbar 11 2

3 Linear Diaphragm Pumps YP-15DU, YP-2DU 6 to 2 l/min at 1 mbar Description YP-15DU YP-2DU Part number l/min 2 l/min Rated pressure 1 mbar 1 mbar Operating range 2 to 2 mbar 2 to 2 mbar Motor type Linear drive Linear drive Voltage 23V 5Hz 23V 5Hz Power consumption at rated pressure 13 W 18 W Ambient temperature -1 to 4 C -1 to 4 C Weight 1.2 kg 1.2 kg Outlet diameter 2 x 8 mm 2 x 8 mm Average sound level 38 db (A) 4 db (A) Chamber block set 1) If 23V 6Hz is required, please consult factory YP-2DU YP-15DU 2 x Leads (3 cm) for power supply 1 x Lead (1 cm) for earth/ground 2 x Diaphragm nut 2 x Diaphragm washer Stock programme

4 Linear Diaphragm Pumps YP-15A, YP-2A 15 to 2 l/min at 1 mbar Description YP-15A YP-2A Part number l/min 2 l/min Rated pressure 1 mbar 1 mbar Operating range 2 to 2 mbar 2 to 2 mbar Motor type Linear drive Linear drive Voltage 23V 5Hz 23V 5Hz Power consumption at rated pressure 13 W 18 W Ambient temperature -1 to 4 C -1 to 4 C Weight 2.4 kg 2.4 kg Outlet diameter 5 or 11 mm 5 or 11 mm Average sound level 33 db (A) 35 db (A) Chamber block set 1) If 23V 6Hz is required, please consult factory YP-2A YP-15A Cable/Euro-plug 1 x Tube connector I.D mm 2 x Diaphragm assembl;y 2 x Diaphragm nut 2 x Diaphragm washer Stock programme

5 Linear Diaphragm Pump YP-2V 2 l/min at 1 mbar Description YP-2V Part number l/min Rated pressure ±1 mbar Operating range -2 to 2 mbar Motor type Voltage Power consumption at rated pressure Linear drive 23V 5Hz 18 W Ambient temperature -1 to 4 C Weight 2.4 kg Inlet / Outlet diameter Rc 1/8 Average sound level 34 db (A) Chamber block set 1) 717 If 23V 6Hz is required, please consult factory YP-2V Cable/Euro-plug 2 x Diaphragm nut 2 x Diaphragm washer ACCESSORIES Tube connector I.D. 8 mm (part number 6126) Vacuum rel. [%] Stock programme 5

6 Linear Diaphragm Pumps YP-4DU, YP-5DU 43 to 5 l/min at 12 mbar Description YP-4DU YP-5DU Part number l/min 5 l/min Rated pressure 12 mbar 12 mbar Operating range 5 to 2 mbar 5 to 2 mbar Motor type Linear drive Linear drive Voltage 23V 5Hz 23V 5Hz Power consumption at rated pressure 42 W 45 W Ambient temperature -1 to 4 C -1 to 4 C Weight 2.5 kg 2.8 kg Outlet diameter 2 x 1 mm 2 x 1 mm Average sound level 49 db (A) 5 db (A) Chamber block set 1) If 23v 6Hz is required, please consult factory YP-5DU YP-4DU 2 x Leads (3 cm) for power supply 1 x Lead (1 cm) for earth/ground 2 x Diaphragm nut 2 x Diaphragm washer Stock programme 6

7 Linear Diaphragm Pumps YP-4VC, YP-5VC, YP-6VC, YP-7VC 43 to 73 l/min at 12 to 18mbar Description YP-4VC YP-5VC YP-6VC YP-7VC Part number l/min 58 l/min 66 l/min 73 l/min Rated pressure ±12 mbar ±12 mbar ±12 mbar ±18 mbar Operating range -2 to 2 mbar -2 to 2 mbar -2 to 2 mbar -2 to 2 mbar Motor type Linear drive Linear drive Linear drive Linear drive Voltage 23V 5Hz 23V 5Hz 23V 5Hz 23V 5Hz Power consumption at rated pressure 4 W 46 W 59 W 85 W Ambient temperature -1 to 4 C -1 to 4 C -1 to 4 C -1 to 4 C Weight 5.1 kg 5.5 kg 5.9 kg 6.2 kg Inlet / Outlet diameter Rc 3/8 Rc 3/8 Rc 3/8 Rc 3/8 Average sound level 39 db (A) 41 db (A) 46 db (A) 48 db (A) Chamber block set 1) If 23V 6Hz is required, please consult factory YP-7VC YP-6VC YP-5VC YP-4VC Cable/Euro-plug 2 x Diaphragm nut 2 x Diaphragm washer 4 2 ACCESSORIES Tube connector I.D. 14 mm (part number 31644) Vacuum rel. [%] Stock programme 7

8 Linear Diaphragm Pump AP-4 45 l/min at 12 mbar Description AP-4 Part number l/min Rated pressure 12 mbar Operating range 5 to 2 mbar Motor type Nominal Voltage Consumption at rated pressure Efficiency at rated pressure Linear drive 23V 5Hz.34 A / 29 W.64 W/l Ambient temperature -1 to 4 C Weight 4.3 kg Outlet diameter 18 mm Average sound level 34 db (A) Chamber block set 1) 758 Air filter and gasket kit 7582 Air filter kit 7583 If 23V 6Hz is required, please consult factory. 1 8 AP-4 2 x Diaphragm gasket 2 x Nut 2 x Washer Cable/Euro-plug Air connector consists of (part number 773) 1 x Outlet hose, angled, 17/5 mm 2 x Hose clamp Air filter and gasket kit consists of: 1 x Air cleaner element 1 x Air cleaner gasket 1 x Cover plate gasket 1 x Noise absorbing net 1 x Tank gasket Stock programme Air filter kit consists of: 5 x Air cleaner element 5 x Air cleaner gasket All listed values are measured at standard atmospheric conditions 8

9 Linear Diaphragm Pumps AP-6N, AP-6/8, AP-8H, AP-1, AP to 125 l/min at 2 mbar Description AP-6N AP-6/8 AP-8H AP-1 AP-12 Part number l/min 6 l/min 82 l/min 18 l/min 125 l/min Rated pressure 2 mbar 2 mbar 2 mbar 2 mbar 2 mbar Operating range 1 to 3 mbar 1 to 3 mbar 1 to 3 mbar 14 to 3 mbar 16 to 3 mbar Motor type Linear drive Linear drive Linear drive Linear drive Linear drive Nominal Voltage 23V 5Hz 23V 5Hz 23V 5Hz 23V 5Hz 23V 5Hz Consumption at rated pressure.26 A / 31 W.34 A / 41 W.8 A / 73 W 1.6 A / 99 W 1.45 A / 128 W Efficiency at rated pressure.66 W/l.68 W/l.89 W/l.92 W/l 1.2 W/l Ambient temperature -1 to 4 C -1 to 4 C -1 to 4 C -1 to 4 C -1 to 4 C Weight 5.8 kg 5.8 kg 6.1 kg 6.1 kg 6.1 kg Outlet diameter 18 mm 18 mm 18 mm 18 mm 18 mm Average sound level 34 db (A) 34 db (A) 35 db (A) 37 db (A) 38 db (A) Chamber block set 1) Air filter and gasket kit Air filter kit Protective switch 1) If 23V 6Hz is required, please consult factory AP-12 AP-1 AP-8H AP-6/8 AP-6N x Diaphragm gasket 2 x Nut 2 x Washer Air filter and gasket kit consists of: 1 x Air cleaner element 1 x Air cleaner gasket 1 x Cover plate gasket 1 x Noise absorbing net 1 x Tank gasket Air filter kit consists of: 5 x Air cleaner element 5 x Air cleaner gasket Protective switch 1) consists of: 1 x Microswitch 2 x Nut 2 x Washer 1 x Cover plate gasket Cable/Euro-plug Air connector consists of (part number 773) 1 x Outlet hose, angled, 17/5 mm 2 x Hose clamp Stock programme All listed values are measured at standard atmospheric conditions 9

10 Linear Diaphragm Pumps LP-15HN, LP-2HN 15 to 2 l/min at 2 mbar LP15/2HN Description LP-15HN LP-2HN Part number l/min 2 l/min Rated pressure 2 mbar 2 mbar Operating range 1 to 3 mbar 1 to 3 mbar Motor type Linear drive Linear drive Nominal Voltage 23V 5Hz 23V 5Hz Consumption at rated pressure.85 A/13 W 1.15 A/2 W Ambient temperature -1 to 4 C -1 to 4 C Weight 8.6 kg 8.6 kg Outlet diameter 18 mm 18 mm Average sound level 43 db (A) 44 db (A) Chamber block set 1) Air filter and gasket kit Air filter kit Protective switch 1) If 23v 6Hz is required, consult factory 4 35 LP-2HN LP-15HN 2 x Diaphragm nut 2 x Diaphragm washer Protective switch 1) consists of: 1 x Microswitch complete with cover plate 1 x Cover plate gasket Air filter and gasket kit consists of: 1 x Air cleaner element 1 x Air cleaner gasket 1 x Cover plate gasket 1 x Noise absorbing net 1 x Tank gasket 2 x L-Hose 2 x L-Clamp Air filter kit consists of: 5 x Air cleaner element 5 x Air cleaner gasket Cable/Euro-plug Air connector (part number 773) consists of: 1 x Outlet hose, angled, 17/5 mm 2 x Hose clamp Stock programme All listed values are measured at standard atmospheric conditions 1

11 Linear Diaphragm Pumps LW-24, LW-3, LW l/min at 2 mbar Power Supply Cord 18 mm Power Supply Cord 18 mm 4X Hose Clamp 2X Hose Clamp Elbow Relief Valve Assy Elbow LW-24 Standard Hose Connection LW-24 LW-3, LW-4 Standard Hose Connection LW-3/4 Description LW-24 LW-3 LW-4 Part number l/min 35 l/min 425 l/min Rated pressure 2 mbar 2 mbar 2 mbar Operating range 1 to 25 mbar 1 to 25 mbar 1 to 25 mbar Motor type Linear drive Linear drive Linear drive Nominal Voltage 23V 5Hz 23V 5Hz 23V 5Hz Consumption at rated pressure 1.8 A/25 W 1.6 A/28 W 2.4 A/4 W Ambient temperature -1 to 4 C -1 to 4 C -1 to 4 C Weight 14.4 kg 16. kg 16. kg Outlet diameter 26 mm 26 mm 26 mm Average sound level 49 db (A) 5 db (A) 51 db (A) Chamber block set 1) Air filter and gasket kit Air filter kit Protective switch 1) Please consult factory if 23V 6Hz is needed. 1) Denotes that part is only available for trained service personnel LW-24 LW-3 LW All listed values are measured at standard atmospheric conditions Chamber block set 1) consists of: 4 x Pump head with valves 4 x Diaphragm assembly 4 x Diaphragm nut 4 x Diaphragm washer Air filter and gasket kit consists of: 1 x Air cleaner element 1 x Air cleaner gasket 1 x Noise absorbing net 1 x Tank gasket 1 x Cover gasket 4 x L-Hose Air filter kit consists of: 5 x Air cleaner element 5 x Air cleaner gasket Stock programme Protective switch 1) consists of: 1 x Microswitch w/cover plate Please note: One unit is equipped with two protective switches Cable/Euro with plug Air connector consisting of LW-24 (7513) 1 x Outlet hose, angled, 17/5 mm 2 x Hose clamp LW-3 & LW-4 (P/N 76) 1 x Outlet hose, angled, 17/5 mm 4 x Hose clamp 1 x Relief valve assembly 1 x Hose connector Accessory Available: Air connector, straight type (P/N 7514) consists of 1 x Outlet hose, straight, 15 mm 2 x Hose clamp 11

12 PUMP AND COMPRESSOR SOLUTIONS FOR OEMS WORLDWIDE gd-thomas.com Gardner Denver Thomas GmbH Livry-Gargan-Str Fürstenfeldbruck Germany T F thomas.de@gardnerdenver.com Gardner Denver Hong Kong, Limited Unit Delta House, 3 On Yiu Street Siu Lek Yuen, Shatin, New Territories Hong Kong T F thomas.hk@gardnerdenver.com Gardner Denver Thomas, Inc Illinois Avenue Sheboygan, WI 5381 USA T F td.usa@gardnerdenver.com The information presented in this material is based on technical data and test results of nominal units. It is believed to be accurate and reliable and is offered as an aid to help in the selection of Thomas products. It is the responsibility of the user to determine the suitability of the product for the intended use and the user assumes all risk and liability in connection therewith. Thomas does not warrant, guarantee or assume any obligation or liability in connection with this information. Models presented in this catalog are representative of the product family. Photos of products pictured in this catalog do not necessarily represent a specific model number. To obtain further information for custom options, contact your local Thomas office. Printed in Germany Form No /217 Gardner Denver Thomas GmbH. All rights reserved.

7010 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm. > > Oil-less > > Low vibration > > Low sound level

7010 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm. > > Oil-less > > Low vibration > > Low sound level 71 Series FEATURES > > Oil-less > > Low vibration > > Low sound level BASE MODEL 71 DC 71 AC 71Z DC 71Z AC TYPICAL APPLICATIONS > > Medical devices > > Clinical analyzers > > Air collector > > Inhalators

More information

7006 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm. > > Oil-less > > Low vibration > > Low sound level

7006 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm. > > Oil-less > > Low vibration > > Low sound level 76 Series FEATURES > > Oil-less > > Low vibration > > Low sound level TYPICAL APPLICATIONS BASE MODEL 76 DC 76 AC 76 BLDC 76Z DC 76Z AC 76Z BLDC > > Medical devices > > Clinical analyzers > > Air collector

More information

8011 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm

8011 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm 811 Series FEATURES > > > > Maintenance free > > Low sound level > > Low vibration > > High performance BASE MODEL 811 AC 811Z AC TYPICAL APPLICATIONS > > Autoclaves > > Analysers > > Vacuum ovens > >

More information

2755 Series BASE MODELS FEATURES 2755BE75 (115/60/1) 2755BGHI75 (230/601/1 & /50/1) 2755CE60 (115/60/1) 2755CGHI60 (230/601/1 & /50/1)

2755 Series BASE MODELS FEATURES 2755BE75 (115/60/1) 2755BGHI75 (230/601/1 & /50/1) 2755CE60 (115/60/1) 2755CGHI60 (230/601/1 & /50/1) FEATURES > > Monolithic head > > Epoxy coated wetted parts > > 17mm shaft & bearing compliment > > Oil-less operation > > Permanently lubricated bearings > > Stainless steel valves > > Die-cast aluminum

More information

3003 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm. >>Oil-less. >>Low vibration. >>Low sound level. >>Compact design >>Lightweight

3003 Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm. >>Oil-less. >>Low vibration. >>Low sound level. >>Compact design >>Lightweight 33 Series FEATURES BASE MOEL >>Oil-less 33 C >>Low vibration 33 LC >>Low sound level 33 BLC >>Compact design >>Lightweight TYPICAL APPLICATIONS >>Patient monitoring >>Anaesthetic control >>Gas detection

More information

5002F Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm

5002F Series FEATURES BASE MODEL TYPICAL APPLICATIONS. Diaphragm 52F Series FEATURES > > Self priming > > Dry running > > Oil-less, non lubricated > > Suitable for continuous operation > > Chemical resistant pump materials for aggressive media BASE MODEL 52F 52F Twin

More information

1/12, 1/6, 1/4, 1/3, 1/2, 3/4 & 1.0 HP

1/12, 1/6, 1/4, 1/3, 1/2, 3/4 & 1.0 HP Articulating Piston TAskair (TA) Series /, /6, /4, /3, /, 3/4 &.0 HP MODELS TA-0-DC (70046) TA-30-DC (7004) TA-40-DC (7005) TA-40-DC (70047) TA-50-DC (70058) TA-50E (70063) TA-50E (70064) TA-60E (70066)

More information

2750 SERIES MODELS FEATURES WOB-L. Standard models 2750CE CGHI50. Other models based on availability and minimum purchase.

2750 SERIES MODELS FEATURES WOB-L. Standard models 2750CE CGHI50. Other models based on availability and minimum purchase. WOB-L 2750 SERIES MODELS models 2750CE50 2750CGHI50 Other models based on availability and minimum purchase. 2750CE60 2750CGHI60 2750CS50 2750CS60 2750TGHI48 2750BE75 2750BGHI75 275OBS75 275OVEF75 2750VHI75

More information

2668CE CHI CHI CE CE CHI CHI VE VGHI44

2668CE CHI CHI CE CE CHI CHI VE VGHI44 WOB-L 2668/2688 SERIES MODELS models 2668CE22 2668CE44 2668CHI22 2668CHI44 2688CE22 2688CE44 2688CHI22 2688CHI44 2688VE44 2688VGHI44 Other models based on availability and minimum purchase. 2668CE32 2668CE40

More information

WOB-L. PISTON Pumps and Compressors. 607/668/669/688/689 Series MODELS:

WOB-L. PISTON Pumps and Compressors. 607/668/669/688/689 Series MODELS: WOB-L PISTON Pumps and Compressors 607/668/669/688/689 Series MODELS: Standard models available. 607CA22, 607CA32, 607CD22, 607CD32 668CE44, 668CGHI44 688CE44, 688CGHI44 669CE44, 669CHGI44 689CE44, 689CGHI44

More information

APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS!

APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS! 4,6,8,16,24,30 APPLIED VACUUM TECHNOLOGY. ASK THE EXPERTS! www.welchvacuum.com/crvpro YOUR BENEFITS Highest reliability for stable operation and long product lifespan Reduced risk of chemical attacks and

More information

Standard Product Catalog

Standard Product Catalog Standard Product Catalog WOB-L Piston MODEL SERIES Air Compressors & Vacuum Pumps LPM @ PSI (PSI) LPM @ IN.HG. (IN.HG.) VOLTAGE TYPE* 0 5 10 20 40 60 80 100 CONTINUOUS INTERMITTENT RESTART 0 5 10 15 20

More information

Improving Lives through Innovation TM. Global Catalog. Compressors, Vacuum Pumps & Liquid Pumps

Improving Lives through Innovation TM. Global Catalog. Compressors, Vacuum Pumps & Liquid Pumps Improving Lives through Innovation TM Global Catalog Compressors, Vacuum Pumps & Liquid Pumps Pumps and Compressor Solutions for OEMs Worldwide As a leader in providing fluidic solutions to Original Equipment

More information

COMPRESSORS, VACUUM & LIQUID PUMPS Global Solutions

COMPRESSORS, VACUUM & LIQUID PUMPS Global Solutions COMPRESSORS, VACUUM & LIQUID PUMPS Global Solutions INTRODUCTION / TABLE OF CONTENTS Pump and Compressor Solutions for OEMs Worldwide As the leader in providing fluidic solutions to Original Equipment

More information

VTE DTE Series Picolino

VTE DTE Series Picolino VTE DTE Series Picolino FUTURES > > Oil-less > > Long lifetime > > Compact design > > Low sound level > > Pulsation free > > Low vibration BASE MODEL VTE 3 DTE 3 VTE 6 DTE 6 VTE 8 DTE 8 VTE 1 DTE 1 TYPICAL

More information

STANDARD PRODUCT CATALOGUE EUROPE

STANDARD PRODUCT CATALOGUE EUROPE STANDARD PRODUCT CATALOGUE EUROPE Vacuum/Pressure & Liquid to 365 l/min Market driven engineering For pumps and compressors, Thomas is the right contact. We understand our customers requirements: quiet

More information

SIDE CHANNEL BLOWERS

SIDE CHANNEL BLOWERS SIDE CHANNEL BLOWERS RT-1 / RT-2 / RT-3 / RT-4 series 23 RT-4 / RT-5 / RT-6 / RT-7 / RT-8 / RT-9 series 24 RT-23 / RT-33 / RT-43 / RT-63 / RT-83 series 25 19 Applications Aeration Swiing pools and whirlpools

More information

DIAPHRAGM PUMPS. SLL series 8 EL-N series 9 EL-S series single system 10 EL-S series twin system 11 OEM assembly pumps 12 Phoe-niX series 14

DIAPHRAGM PUMPS. SLL series 8 EL-N series 9 EL-S series single system 10 EL-S series twin system 11 OEM assembly pumps 12 Phoe-niX series 14 Bild fehlt noch DIAPHRAGM PUMPS SLL series 8 EL-N series 9 EL-S series single system 1 EL-S series twin system 11 OEM assembly pumps 12 Phoe-niX series 14 5 Applications Water treatment and environmental

More information

SINGLE STAGE TWO STAGES

SINGLE STAGE TWO STAGES BLOWERS CATALOG Table of contents SINGLE STAGE TWO STAGES 3 4 1 1 5 6 7 8 9 10 11 12 Weight (Kg) 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 2RSC 50-65 Performance curve for Vacuum

More information

Solenoid valves VZWF, force pilot operated

Solenoid valves VZWF, force pilot operated q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity qready for dispatch

More information

Rotary Vane Compressors and Vacuum Pumps

Rotary Vane Compressors and Vacuum Pumps Rotary Vane Compressors and Vacuum Pumps The Gast Group Difference The Gast Group Difference For over 9 years, Gast Manufacturing has been providing innovative air solutions to a broad breadth of customers.

More information

Peristaltic Pumps FEATURES BASE MODEL TYPICAL APPLICATIONS. Peristaltic SR10/30 SR10/50 SR10/100 SR18 SR25

Peristaltic Pumps FEATURES BASE MODEL TYPICAL APPLICATIONS. Peristaltic SR10/30 SR10/50 SR10/100 SR18 SR25 Peristaltic Pumps FEATURES > > Compact design > > Quick change of cassette (SR10)/tubing (SR25, SR18) > > Endless tubing possible (SR10) > > Self priming > > Safe to run dry > > Maintenance free > > Different

More information

V-Series. Oil-less Rotary Vane

V-Series. Oil-less Rotary Vane V-Series Oil-less Rotary Vane Oil-less rotary vane vacuum pumps, compressors and pressure-vacuum pumps The compact V-VTE vacuum pumps and V-DTE compressors are each available in four sizes. Low noise and

More information

DATA PD LK..., LP... Product PD Air Compressors. Function. Technical Features

DATA PD LK..., LP... Product PD Air Compressors. Function. Technical Features Commercial Vehicle Systems Product Doc. No. Y210611 DATA (EN - Rev. 000) Function The are piston-type and are used for generating compressed air to supply the air brake system, air suspension and auxiliary

More information

Technical Datasheet. Differential Pressure Gauge Diaphragm DG Range. Performance characteristics. Product applications. How can we help you?

Technical Datasheet. Differential Pressure Gauge Diaphragm DG Range. Performance characteristics. Product applications. How can we help you? Technical Datasheet Differential Pressure Gauge Diaphragm DG Range Nominal Diameter options of 100mm & 150mm. Degree of Protection IP55/IP65. Stainless steel enclosure as standard. Blowout Protection.

More information

HEPTADRY. Dry screw pumps. Optimum ultimate pressure. Absolutely oil-free. Cool-running.

HEPTADRY. Dry screw pumps. Optimum ultimate pressure. Absolutely oil-free. Cool-running. HEPTADRY Dry screw pumps. Optimum ultimate pressure. Absolutely oil-free. Cool-running. HEPTADRY Dry screw pumps. Optimum ultimate pressure. Absolutely oil-free. Cool-running. With HeptaDry, Pfeiffer Vacuum

More information

MANN Europiclon Two stage air cleaner modular system

MANN Europiclon Two stage air cleaner modular system MANN Europiclon Two stage air cleaner modular system Background picture: Claas 7 MANN Europiclon... Applications The MANN Europiclon is the ideal intake air cleaner for construction and agricultural machinery,

More information

N086, N186, N786. Pressure retaining valve, Plastic

N086, N186, N786. Pressure retaining valve, Plastic Pressure retaining valve, Plastic Construction The GEMÜ N086, N186 and N786 pressure retaining valves are used to provide a constant back pressure in process plant. If the inlet pressure rises above a

More information

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE

product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - Air-cooled condensers 09PE product selection data Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers - 09PE Translation of the original document N 20030, 03.2015 Use The 09PE range, available

More information

L04 L29 (5 40 HP) FIXED-SPEED ROTARY SCREW COMPRESSORS. L-Series

L04 L29 (5 40 HP) FIXED-SPEED ROTARY SCREW COMPRESSORS. L-Series L04 L29 (5 40 HP) FIXED-SPEED ROTARY SCREW COMPRESSORS L-Series Advanced Technology Inspired Simplicity A Better Approach Champion has a long history of manufacturing compressed air equipment. With our

More information

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE

product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE product selection data Slim design Acoustic comfort 40% smaller footprint Drycoolers 09VE Translation of the original document N 20033, 03.2015 Drycoolers Use Drycoolers in this range are mainly designed

More information

AIR COMPRESSORS, VACUUM PUMPS & LIQUID PUMPS

AIR COMPRESSORS, VACUUM PUMPS & LIQUID PUMPS Lk1e Linear-motor-driven Free Piston Pumps and other Pumps for various applications AIR COMPRESSORS, VACUUM PUMPS & LIQUID PUMPS GENERAL CATALOG Our air compressors and vacuum pumps are unique products

More information

Series 2 Product Family Diaphragm Compressors & Vacuum Pumps Piston Compressors Revised September 2015

Series 2 Product Family Diaphragm Compressors & Vacuum Pumps Piston Compressors Revised September 2015 Series Product Family Diaphragm Compressors & Vacuum Pumps Piston Compressors Revised September s Max. Flow Max. Vacuum Max. Intermittent Pressure DBLDC., DBLDC6., PBLDC., PBLDC6., D9BRLC., D9BRLC7., P9BRLC..slpm

More information

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE

PRODUCT SELECTION DATA. Performance. Flexibility. Intelligence. Energy optimisation. Acoustic optimisation. Drycoolers 09PE PRODUCT SELECTION DATA Performance Flexibility Intelligence Energy optimisation Acoustic optimisation Drycoolers 09PE Translation of the original document N 20030, 02.2017 Use 09PE The 09PE range is particularly

More information

WATERFLUX 3070 Quick Start

WATERFLUX 3070 Quick Start WATERFLUX 3070 Quick Start Battery powered electromagnetic water meter Electronic Revision ER 4.3.0_ up to ER 4.3.4_ (SW.REV 4.2.2_ up to 4.2.5_) KROHNE CONTENTS WATERFLUX 3070 1 Safety instructions 4

More information

NCF fans 60Hz. Protection class IP 55

NCF fans 60Hz. Protection class IP 55 The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

HENALINE. A complete line of single-stage rotary vane pumps for low and medium vacuum applications. Safe. Reliable. Powerful.

HENALINE. A complete line of single-stage rotary vane pumps for low and medium vacuum applications. Safe. Reliable. Powerful. HENALINE A complete line of single-stage rotary vane pumps for low and medium vacuum applications. Safe. Reliable. Powerful. HENALINE A complete line of single-stage rotary vane pumps for low and medium

More information

UD and UC Gear pump unit

UD and UC Gear pump unit 1-19-EN for SKF CircOil or hydraulic lubrication systems General Information The UC and UD gear pump units are vertically or horizontally arranged units that are used in hydraulic or circulating-oil lubrication

More information

Spec.No. CBF2525-VBVB-01E-1. Orion Model CBF2525-VBVB-01. Date Aug APPD CKD DWN. Kuroiwa Yamada Takei Takahashi ORION MACHINERY CO., LTD.

Spec.No. CBF2525-VBVB-01E-1. Orion Model CBF2525-VBVB-01. Date Aug APPD CKD DWN. Kuroiwa Yamada Takei Takahashi ORION MACHINERY CO., LTD. Spec.No. CBF2525-VBVB-01E-1 Orion Trade Name DRY PUMP Orion Model CBF2525-VBVB-01 Date Aug.30.2011 APPD CKD DWN Y. F. N. Y. Kuroiwa Yamada Takei Takahashi ORION MACHINERY CO., LTD. Spec.No. CBF2525-VBVB-01E-1

More information

Laboratory Vacuum Catalog

Laboratory Vacuum Catalog Laboratory Vacuum Catalog Application Specific Pumps High Vacuum Rotary Vane Pumps Dry (oil-free) Vacuum Pumps Components, Traps & Gauges Compact Direct Drive Welch Vacuum Pumps Lightweight, Compact, High

More information

INSTRUCTION MANUAL INSTALLATION & MAINTENANCE LA-100/ LA-120

INSTRUCTION MANUAL INSTALLATION & MAINTENANCE LA-100/ LA-120 MEDO LA BLOWER INSTRUCTION MANUAL INSTALLATION & MAINTENANCE LA-8B/ LA-45B LA-60B/ LA-80B LA-100/ LA-10 This instruction manual should be read and understood thoroughly before any installation and maintenance

More information

Solenoid valves VZWP, servo-controlled

Solenoid valves VZWP, servo-controlled Key features and overview Function The solenoid valve VZWP-L- is a servo-controlled 2/2-way valve with solenoid coil. The solenoid valve is closed when de-energised. When energised, the differential pressure

More information

INSTRUCTION MANUAL FOR LINEAR COMPRESSORS

INSTRUCTION MANUAL FOR LINEAR COMPRESSORS CONTENTS INSTRUCTION MANUAL FOR LINEAR COMPRESSORS MODEL EL-60 EL-10W EL-80-15 EL-150 EL-80-17 EL-00 EL-100 1. Parts name. Instructions -1 Prior to operation 3 - Storage and transfer 3-3 Installation 4

More information

Environmental Technology Linear Diaphragm Pumps Side Channel Blowers Diffusers.

Environmental Technology Linear Diaphragm Pumps Side Channel Blowers Diffusers. Environmental Technology Linear Diaphragm Pumps Side Channel Blowers Diffusers www.bibus.co.uk BIBUS - Network of Competencies We are the link between the manufacturing plants and our customers. Our many

More information

AERZEN BULK VEHICLE BLOWER

AERZEN BULK VEHICLE BLOWER AERZEN BULK VEHICLE BLOWER A E R Z E N E R M A S C H I N E N F A B R I K GMBH G1-071 05 EN 250 11.2012 Fields of application and principle of operation Aerzen bulk vehicle blowers have been specifically

More information

DELTA V 1p 400V 3p

DELTA V 1p 400V 3p COMPRESSOR DELTA 2 230V 1p 400V 3p QR-CODES Download a QR-Code App on your smartphone and scan the QR-Code or use the link directly in your browser. GENERAL 4 Compressor Delta 2 Type 230V 1p & 400V 3p

More information

Data sheet. D-2011/05/ Date: 07/2013. Type TK1 CNG. CNG Fuelling Nozzle. for time filling of cars. WEH - We Engineer Hightech

Data sheet. D-2011/05/ Date: 07/2013. Type TK1 CNG. CNG Fuelling Nozzle. for time filling of cars. WEH - We Engineer Hightech Data sheet D-2011/05/00160-4-3 Date: 07/2013 Type TK1 CNG CNG Fuelling Nozzle for time filling of cars WEH - We Engineer Hightech General Description Sliding sleeve Media inlet Features Compatible with

More information

Oil-free piston compressors KK and piston vacuum pumps KV

Oil-free piston compressors KK and piston vacuum pumps KV Oil-free piston compressors KK and piston vacuum pumps KV Installation and Operating Instructions 0678106030L02 1707V003 Contents Important information 1 About this document 2 1.1 Warnings and symbols

More information

Eclipse RatioAir Burners

Eclipse RatioAir Burners Parameter Maximum Input, BTU/hr (kw) 1, Minimum Input, BTU/hr (kw) Lower inputs may be achieved. Contact factory. Main Gas Inlet Pressure, "w.c. (mbar) 3 Fuel pressure at ratio regulator inlet. High Fire

More information

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP Product Information Stepper Motor-driven Diaphragm Dosing Pump Reliable dosing of chemicals Stepper motor driven diaphragm pumps are particularly suitable for highly accurate, reproducible industrial dosing

More information

NEOSTAR NEW! Condensers. www. 18 kw 1250 kw

NEOSTAR NEW! Condensers. www. 18 kw 1250 kw Condensers NEOSTAR 18 kw 12 kw Friga-Bohn reserves itself the right to make changes at any time without preliminary notice - Photos non-contractual www NEW! The air cooled condenser units of the new NEOSTAR

More information

Swing Piston Compressors and Vacuum Pumps

Swing Piston Compressors and Vacuum Pumps Swing Piston Compressors and Vacuum Pumps NPK 018 AC Pressure NPK 018 DC Pressure NPK 018 AC Vacuum NPK 018 DC Vacuum Operating and Installation Instructions Read and observe these Operating and Installation

More information

ac-500 hot surface ignition & i.i.d.spark ignition vertically fired gas convection oven

ac-500 hot surface ignition & i.i.d.spark ignition vertically fired gas convection oven ac-00 hot surface ignition & i.i.d.spark ignition vertically fired gas convection oven REPLACEMENT PARTS LIST Effective june, 0 Superseding All Previous Parts Lists. The Company reserves the right to make

More information

DEMAMaster TM DM-811 Series Installation Manual

DEMAMaster TM DM-811 Series Installation Manual R TM MADE IN USA I-807 Page 1 of 6 System Overview The DEMAMaster series is designed for long reliable use with simplicity in mind for both the installer and user. The DEMAMaster dispenses using the reliable

More information

AC-500 HOT SURFACE IGNITION & I.I.D.SPARK IGNITION VERTICALLY FIRED GAS CONVECTION OVEN REPLACEMENT PARTS LIST

AC-500 HOT SURFACE IGNITION & I.I.D.SPARK IGNITION VERTICALLY FIRED GAS CONVECTION OVEN REPLACEMENT PARTS LIST AC-00 HOT SURFACE IGNITION & I.I.D.SPARK IGNITION VERTICALLY FIRED GAS CONVECTION OVEN REPLACEMENT PARTS LIST EFFECTIVE APRIL 9, 0 Superseding All Previous Parts Lists. The Company reserves the right to

More information

NCF 60 Hz. Protection class IP 55

NCF 60 Hz. Protection class IP 55 The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

L04 L290 (5 400 HP) FIXED-SPEED ROTARY SCREW COMPRESSORS. L-Series

L04 L290 (5 400 HP) FIXED-SPEED ROTARY SCREW COMPRESSORS. L-Series L04 L290 (5 400 HP) FIXED-SPEED ROTARY SCREW COMPRESSORS L-Series Advanced Technology Inspired Simplicity A Better Approach Gardner Denver has a long history of manufacturing compressed air equipment.

More information

Liquid ring compressors

Liquid ring compressors Liquid ring compressors KPH 65212, KPH 65218 Compression pressures: Suction volume flow: 2 to 7 bar 375 to 660 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring compressors are displacement compressors

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS 2012 2 The CALEFFI SOLAR product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

Linear Air Pumps SUN MINES ELECTRICS CO.,LTD 三敏電機股份有限公司

Linear Air Pumps SUN MINES ELECTRICS CO.,LTD 三敏電機股份有限公司 電磁式空氣泵 SUN MINES ELECTRICS CO.,LTD 三敏電機股份有限公司 2018 The works without any sliding parts but only oil-free components, so the air pump requires no lubrication and it delivers the air without any pollution.

More information

HIGH PRESSURE COMPRESSORS FOR NATURAL GAS REFUELLING OF VEHICLES FOR PRIVATE USE. CATALOG 2018 CNG FILLING STATIONS

HIGH PRESSURE COMPRESSORS FOR NATURAL GAS REFUELLING OF VEHICLES FOR PRIVATE USE. CATALOG 2018 CNG FILLING STATIONS HIGH PRESSURE COMPRESSORS FOR NATURAL GAS REFUELLING OF VEHICLES FOR PRIVATE USE. CATALOG 2018 CNG FILLING STATIONS CNG 3 EVO 50 l/min 3 m 3 /h TECHNICAL DATA REFUELLING TIME 80 l Cylinder (kg 11.5) 0/200

More information

Data sheet. D-2011/05/ Date: 02/2013. Type TS50 CNG. Fuelling System. for installation in cars FUTURE. TECHNOLOGY. TODAY.

Data sheet. D-2011/05/ Date: 02/2013. Type TS50 CNG. Fuelling System. for installation in cars FUTURE. TECHNOLOGY. TODAY. Data sheet D-2011/05/00160-3-3 Date: 02/2013 Type TS50 CNG Fuelling System for installation in cars FUTURE. TECHNOLOGY. TODAY. General Description Features Integrated WEH TN1 CNG receptacle (NGV1) with

More information

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF

GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-300-VEF MBC-700-VEF MBC-1200-VEF GasMultiBloc Combined regulator and safety valve Infinitely variable air/ gas ratio control mode MBC-00-VEF 7.03 Max. operating pressure 30 mbar (3 kpa) Compact design High flow values Low weight Low power

More information

COMPACT DRY PUMPING SYSTEMS DRYTEL SERIES

COMPACT DRY PUMPING SYSTEMS DRYTEL SERIES COMPACT DRY PUMPING SYSTEMS DRYTEL SERIES COMPACT DRY PUMPING SYSTEMS DRYTEL SERIES Dry pumping units The Drytel series of products are dry pumping systems that include an Adixen molecular drag pump (MDP)

More information

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing echnical data sheet LH4A.. Linear actuators for operating air control dampers and slide valves in ventilation and air-conditioning systems For air control dampers up to approx. m Actuating force 5 ominal

More information

Data sheet. Etaline GN /3002 G11 Version no.: 1 Inline pump. Operating data. Design. Clean water. Efficiency 61.6 % 20.0 C.

Data sheet. Etaline GN /3002 G11 Version no.: 1 Inline pump. Operating data. Design. Clean water. Efficiency 61.6 % 20.0 C. Data sheet Item no.: 1900 Page: 1 / 5 Operating data Pumped medium Water Actual flow rate 72.19 m ³/h Operating data determined for maximum inlet pressure Actual developed head 70.26 m Clean water Efficiency

More information

MEDO LA BLOWER INSTRUCTION MANUAL INSTALLATION & MAINTENANCE LA-28B/ LA-45B LA-60B/ LA-80B LA-100/ LA-120

MEDO LA BLOWER INSTRUCTION MANUAL INSTALLATION & MAINTENANCE LA-28B/ LA-45B LA-60B/ LA-80B LA-100/ LA-120 MEDO LA BLOWER INSTRUCTION MANUAL INSTALLATION & MAINTENANCE LA-8B/ LA-5B LA-60B/ LA-80B LA-00/ LA-0 This instruction manual should be read and understood thoroughly before any installation and maintenance

More information

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG Productinformatie A.U.K. MÜLLER GMBH & CO. KG Solenoid valves Control valves Special valves and systems GmbH & Co. KG Dresdener Str. 162 D-40595 Düsseldorf/Germany Tel.: +49(0)211-7391-0 Fax: +49(0)211-7391-281

More information

We are world-leading. innovators in oil-free OEM vacuum pumps & compressors. gseint.com

We are world-leading. innovators in oil-free OEM vacuum pumps & compressors. gseint.com We are world-leading innovators in oil-free OEM vacuum pumps & compressors. gseint.com Your world-class OEM partner GSE is one of the world s leading manufacturers of oil-free OEM vacuum pumps and compressors.

More information

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15 17 Elster GmbH Edition 1.17 Translation from the German 519 D F NL I E DK S N P GR TR CZ PL RUS H www.docuthek.com Operating instructions Solenoid valve for gas VG VG 15/1 Contents Solenoid valve for gas

More information

Products RUVAC WA/WAU 251 to 2001 Roots Vacuum Pumps with Air-Cooled Flange-Mounted Motors

Products RUVAC WA/WAU 251 to 2001 Roots Vacuum Pumps with Air-Cooled Flange-Mounted Motors Products RUAC WA/WAU 251 to 2001 Roots acuum Pumps with Air-Cooled Flange-Mounted Motors RUAC WAU 2001 single-stage Roots vacuum pump, depicted with a 160 ISO-K collar flange Advantages to the User - Two

More information

Transport SBU. Product Overview

Transport SBU. Product Overview Product Overview Compressors Our range includes the following machines GD150, SC200 & J200 E490 RTL 80 & 100 XK 12 & 18 Bulkline 650 & 1000 D9000 T5CDL9 and T5CDL12 Cycloblowers ROL 190M, 280M, 400M &

More information

Lubricated Rotary Screw Air Compressors

Lubricated Rotary Screw Air Compressors Lubricated Rotary Screw Air Compressors 45 110 kw an industry leader Leadership Since 1965, Sullair has been recognized worldwide as an innovator and leader in rotary screw compression and vacuum technology.

More information

OwNErS MaNual with INSTallaTION INSTrucTIONS

OwNErS MaNual with INSTallaTION INSTrucTIONS OwNErS MaNual with INSTallaTION INSTrucTIONS EMISSIONS KIT light duty 6.2l chevrolet/gm diesel for use on gm 6.2L diesel trucks equipped with the banks sidewinder turbo system this manual is for use with

More information

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01

GasBloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating GB-M(P) 057 D01 Gasloc Multifunctional gas control Combined regulator and safety shut-off valves Electrically modulating G-M(P) 057 D01 Two stage operating mode G-(LEP)Z 057 D01 Technical Description Multifunctional gas

More information

MANN+HUMMEL ProVent. Oil separator for closed and open crankcase ventilation

MANN+HUMMEL ProVent. Oil separator for closed and open crankcase ventilation MANN+HUMMEL ProVent Oil separator for closed and open crankcase ventilation ProVent high performance with distinct advantages The development of the whole MANN+HUMMEL ProVent product family was directed

More information

Data sheet. Page: 1 / 5 ETN GG A 11GA201502B. Operating data. Design. Requested developed head m. Efficiency 74.

Data sheet. Page: 1 / 5 ETN GG A 11GA201502B. Operating data. Design. Requested developed head m. Efficiency 74. Data sheet Page: 1 / 5 Operating data Requested flow rate 160.00 m³/h Actual flow rate 159.85 m³/h Operating data determined for maximum inlet pressure Actual developed head 20.96 m Requested developed

More information

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pumps and Compressors Operating Instructions Read and observe these Operating Instructions! Diaphragm Vacuum Pumps and Compressors N145 AN.18 N145 AT.18 N145 AV.18 N145.1.2 AN.18 N145.1.2 AT.18 N145.1.2 AV.18 KNF Neuberger

More information

NCF fans 50 Hz. Protection class IP 55

NCF fans 50 Hz. Protection class IP 55 The Nederman NCF Fans have direct drive motors which means a safe and cost effective operation. Installing an energy efficient NCF fan with our other Nederman products saves time and reduces energy costs.

More information

KIT. light duty 6.2L chevrolet/gm diesel. for use on gm 6.2L diesel trucks equipped with the banks sidewinder turbo system

KIT. light duty 6.2L chevrolet/gm diesel. for use on gm 6.2L diesel trucks equipped with the banks sidewinder turbo system owners manual with installation instructions EMISSIONS KIT light duty 6.2L chevrolet/gm diesel for use on gm 6.2L diesel trucks equipped with the banks sidewinder turbo system this manual is for use with

More information

Compressed Air Systems Catalog

Compressed Air Systems Catalog Compressed Air Systems Catalog Reciprocating Rotary Screw Aftermarket/Parts 2 Advantage Series The Advantage Series air compressor units come with all the normally ordered accessories already mounted and

More information

VACOMASS. Technical information VACOMASS square diaphragm control valve

VACOMASS. Technical information VACOMASS square diaphragm control valve VACOMASS Technical information VACOMASS square diaphragm control valve Diaphragm control valve with a square shaped control aperture and falling flow axis VACOMASS SQUARE DIAPHRAGM CONTROL VALVE The VACOMASS

More information

COMPONENTS FOR SOLAR THERMAL SYSTEMS

COMPONENTS FOR SOLAR THERMAL SYSTEMS COMPONENTS FOR SOLAR THERMAL SYSTEMS The Caleffi Solar product range has been specially developed for use in solar thermal systems, where high temperatures can normally be reached and where, depending

More information

Electropneumatic pressure regulator EPP4 Series. Connection G ½. Catalogue 8684/UK G ½"

Electropneumatic pressure regulator EPP4 Series. Connection G ½. Catalogue 8684/UK G ½ Electropneumatic pressure regulator EPP4 Series Connection G ½ Catalogue 8684/UK G ½" The ECONOMIC solution which meets the market requirements Compact design and lightweight for ease of installation and

More information

Pressure/vacuum switch (V)PE-1/8-...(-SW) PE-PK-...(-SW)

Pressure/vacuum switch (V)PE-1/8-...(-SW) PE-PK-...(-SW) Pressure/vacuum switch (V)PE-1/8-...(-SW) PE-PK-...(-SW) (en) Operating instructions 8068554 2017-05c [8068556] Original instructions Symbols: Warning, Caution Fitting and commissioning to be carried out

More information

INDUSTRIALS GROUP. Screw Compressors. ESM Fixed Speed & VS Variable Speed

INDUSTRIALS GROUP. Screw Compressors. ESM Fixed Speed & VS Variable Speed INDUSTRIALS GROUP Screw Compressors ESM 30 132 Fixed Speed & VS 30 132 Variable Speed GARDNER DENVER COMPRESSED AIR TECHNOLOGIES The perfect fit to maximise productivity The growing industrial demand for

More information

MECAIR 200 SERIES THREADED VALVES CLEAN AIR SOLUTIONS PRODUCT LEAFLET

MECAIR 200 SERIES THREADED VALVES CLEAN AIR SOLUTIONS PRODUCT LEAFLET 200 SERIES CLEAN AIR SOLUTIONS - 200 SERIES CONSTRUCTION FEATURES VALVE Lock nut DESCRIPTION COVER Diecast aluminium (anodised) BODY Diecast aluminium (anodised) PILOT BASE Aluminium (anodised) PILOT Stainless

More information

AIR COMPRESSOR, VACUUM PUMP & LIQUID PUMP

AIR COMPRESSOR, VACUUM PUMP & LIQUID PUMP Lk1f Linear-motor-driven Free Piston Pumps and other Pumps for various applications AIR COMPRESSOR, VACUUM PUMP & LIQUID PUMP GENERAL CATALOG Our air compressors and vacuum pumps are unique products featuring

More information

Diaphragm Vacuum Pumps and Compressors

Diaphragm Vacuum Pumps and Compressors Operating Instructions Read and observe these Operating Instructions! Diaphragm Vacuum Pumps and Compressors N022 AN.18 N022 AT.18 N022 AV.18 N026.1.2 AN.18 N026.1.2 AT.18 N026.1.2 AV.18 N026.3 AN.18 N026.3

More information

iqpc912 PARTS MANUAL PC912PM v1

iqpc912 PARTS MANUAL PC912PM v1 iqpc912 PARTS MANUAL PC912PM v1 See Page 10 See Page 6 & See Page 12 See Page 2 See Page 16 See Page 1 See Page 1 See Page See Page 22 See Page 20 See Page 2 See Page 26 3 16 19 1 17 1 1 11 13 12 10 9

More information

ELECTRONIC CONTROLLER

ELECTRONIC CONTROLLER BRQB011206E THE INSIDE STORY OF THE QB3: IP65 enclosure allows it to withstand the elements and be washed down without harm Precision pressure control vacuum to 150 psi (10.34 bar ) at high flow rate saves

More information

High CATALOG. Efficiency. Pilot Operated Safety Valves Series 810 Pop Action Series 820 Modulate Action. The-Safety-Valve.com

High CATALOG. Efficiency. Pilot Operated Safety Valves Series 810 Pop Action Series 820 Modulate Action. The-Safety-Valve.com High Efficiency Pilot Operated Safety Valves Series 10 Pop Action Series 20 Modulate Action CATALOG The-Safety-Valve.com Valve finder How to find the right product group High operating to set pressure

More information

EFFICIENCY REGULATIONS FOR MOTORS AND MOTOR SYSTEMS

EFFICIENCY REGULATIONS FOR MOTORS AND MOTOR SYSTEMS Intelligent Drivesystems, Worldwide Services EFFICIENCY REGULATIONS FOR MOTORS AND MOTOR SYSTEMS EN INTERNATIONAL REQUIREMENTS EFFICIENCY REGULATIONS FOR MOTORS AND MOTOR SYSTEMS Electric drives in industrial

More information

S200-P Passport Series Fire Pump Service Parts List

S200-P Passport Series Fire Pump Service Parts List Document Number Issue Date 04/08/13 Rev. Date 9/24/18 S200-P Passport Series Fire Pump Service Parts List Index: Component See Pages Body and Impeller 2, 3 Pedestal and Primers 4, 5 Cross Section Views

More information

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM

FRM. Medium Pressure Regulator. Medium pressure regulator Type FRM FRM Medium Pressure Regulator Medium pressure regulator Type FRM Direct acting pressure regulator with adjustable setpoint springs and modular mounted safety shutoff valve (SAV) In compliance with EN 334

More information

Proportional directional control valves MPYE

Proportional directional control valves MPYE Key features General information The directly actuated proportional directional control valve has a position-controlled spool. This transforms an analogue input signal into a corresponding opening cross-section

More information

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07 GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) - B07 7.08 Printed in Germany Rösler Druck Edition 08.00 Nr. 9 6 Technical description

More information

PRESSURE REGULATOR. Lucifer EPP 4 - Basic. Description. Technical data

PRESSURE REGULATOR. Lucifer EPP 4 - Basic. Description. Technical data Description EPP 4 - Basic is an electropneumatic pressure regulator which, by means of an integrated electronic control system and pulse width modulated solenoid valves, controls the outlet pressure proportionally

More information

Pressure transmitter for industrial applications Type MBS 4510

Pressure transmitter for industrial applications Type MBS 4510 MAKING MODERN LIVING POSSIBLE Data sheet Pressure transmitter for industrial applications Type MBS 4510 The high accuracy flush diaphragm pressure transmitter MBS 4510 is designed for use in non-uniform,

More information

The factory-set pressure switches.

The factory-set pressure switches. The factory-set pressure switches. Pressure switch 901 with factory-set pressure setting TUV. SUDWEST BAUMUSTER.. GEPRUFT. Application Factory-set pressure switch monitoring overpressure, vacuum or differential

More information