SOAPP-CT.25 WorkStation 11/1/00. Equipment List Project: Sample Outputs Conceptual Design: Cogen, 1 x 27 MW, NG, Quarterly
|
|
- Homer Mosley
- 6 years ago
- Views:
Transcription
1 GENERAL PROJECT DATA Ambient Conditions Maximum Site Ambient Dry Bulb Temp F Maximum Site Ambient Wet Bulb Temp F Minimum Site Ambient Dry Bulb Temp F Site Average Annual Rainfall in/yr Site Maximum Daily Rainfall 7.00 in/day Site Elevation Above Mean Sea Level ft Design Basis Unit Cycle Configuration Cogeneration Number of Combustion Turbines 1 Number of HRSG's 1 Unit Frequency Market 60 Hz Primary Fuel - CT Natural Gas Secondary Fuel - CT None Primary Fuel - DB Natural Gas Secondary Fuel - DB None Water Treating System Source of Make-up Water Well Water STRUCTURAL DESIGN DATA Enclosures Power Block Enclosure Length ft Power Block Enclosure Width Power Block Enclosure Height ft Water Treatment Enclosure Length ft Water Treatment Enclosure Width ft Water Treatment Enclosure Height ft HRSG Enclosure No Approximate Plant Dimensions Approximate Unit Land Area Requirement 2.29 acres Approximate Length of Main Roadway ft Approximate Pipe Bridge Length for Natural Gas Supply Pipe ft Approximate Pipe Bridge Length for Export Steam Pipe ft Approximate Pipe Bridge Length for Main Pipe Header Approximate Pipe Bridge Length for CT Pipe Leads ft Approximate Pipe Bridge Length for HRSG Pipe Leads ft Approximate Pipe Bridge Length for Treated Water Main Pipe ft Foundations/Substructure Plant Seismic Zone Location Zone 0 Foundation Grade Beam Stacks Bypass Stack(s) - Number 1 Inside Diameter at Top of HRSG Bypass Stack(s) 9.00 ft Top Height Above Grade of HRSG Bypass Stack(s) ft Material of Construction for HRSG Bypass Stack(s) A238 Carbon Steel w/ 409 Diverter Valve Height ft Diverter Valve Length ft Diverter Valve Width ft Main Stack(s) - Number 1 Page 1
2 Inside Diameter at Top of Main Stack(s) 9.78 ft Minimum Thickness at Top of Main Stack(s).25 in Main Stack Top Height Above Grade ft Material of Construction for Main Stack(s) Steel COMBUSTION TURBINE DATA Turbine/Generator Data Number of CTs in Plant Design 1 CT NOx Control Technology, Natural Gas Firing Water Injection CT NOx Emission 15% O2 - Natural Gas % O2 CT Gross Output, per CT 28, kw CT Gross Heat Rate (LHV) 9, Btu/kWh CT Exhaust Gas Mass Flow Rate 665, lb/h CT Exhaust Gas Temperature F CT Generator Air Cooled Inlet Air Filtration Data Combustion Turbine Inlet Filter Static Filter Combustion Turbine Inlet Filter Height ft Combustion Turbine Inlet Filter Length ft Combustion Turbine Inlet Filter Width ft Number of Barrier Filters 70 Hours Before Change Out of Barrier Filters 7, Number of Prefilters 70 Hours Before Change Out of Prefilters 2, HEAT RECOVERY STEAM GENERATOR DATA HRSG Design Number of Heat Recovery Steam Generators (HRSG's) 1 Number of Pressure Levels 2 High Pressure Drum Pinch Point Temp F High Pressure Steam Drum Approach Temp F Low Pressure Drum Pinch Point Temp F Low Pressure Steam Drum Approach Temp.00 F HRSG Dimensions HRSG Height ft HRSG Length ft HRSG Width ft Deaerator Deaerator Standalone Deaerator Deaerator Cond Inlet Perf. Pt. Mass Flow 122, lb/h Deaerator Cond Inlet Perf. Pt. Pressure psia Deaerator Cond Inlet Perf. Pt. Temperature F Deaerator Vent Losses Perf. Pt. Mass Flow lb/h Duct Burners Duct Burner Included Yes Duct Burner Primary Fuel Natural Gas Number of Duct Burner Elements 2 Duct Burner Width ft Duct Burner Height ft Duct Burner Cooling Air Fan.33 hp Page 2
3 Duct Burner Cooling Air Fan Auxiliary Power.50 kw PUMP DATA High Pressure Feed Pumps Horizontal Split-Cage Mul gpm Net Developed Head 1, ft H2O hp Low Pressure Feed Pumps Horizontal Split-Cage gpm Net Developed Head ft H2O 1.00 hp Condensate Pumps Horizontal Split-Cage gpm Net Developed Head ft H2O hp Miscellaneous Pumps Pretreatment Backwash Transfer Pumps Vertical 9.98 gpm ft H2O.50 hp Waste Water Pumps Horizontal Split Cage gpm ft H2O hp Water Treatment System Makeup Pumps Horizontal Split Cage gpm ft H2O hp Water Treatment System Raw Water Pumps Vertical gpm ft H2O hp BOP EQUIPMENT DATA Instrument & Station Air Compressors Screw Page 3
4 Number ft3/min-std Discharge Pressure psig hp Number of Receivers 2.00 Volume of Receivers ft3 Instrument Air Dryers Dessicant Aftercoolers & Moisture Separators Included Yes Water Treatment System Number of Parallel Trains Water Treatment System Auxiliary Power kw Total Water Treatment System 18, gph TANKS Treated Water Storage Tank Number 1 Tank 277, gal Tank Diameter ft Tank Height ft Neutralization Tank and Agitator Number 1 Neutralization Tank 20, gal Neutralization Tank Diameter ft Neutralization Tank Height ft Number of Neutralization Tank Agitators Neutralization Tank Agitator hp Oil/Water Separators Number 1 Corrugated Plate gpm PIPING DATA Fuel Oil Piping Natural Gas Piping Plant Nat Gas Header Pipe Size in Plant Nat Gas Header Pipe Schedule Plant Nat Gas Header Pipe Length ft CT Nat Gas Header Pipe Size 2.00 in CT Nat Gas Header Pipe Schedule CT Nat Gas Header Pipe Length CT Nat Gas Branch Pipe Size 2.00 in CT Nat Gas Branch Pipe Schedule CT Nat Gas Branch Pipe Length ft HRSG Nat Gas Header Pipe Size HRSG Nat Gas Header Pipe Schedule HRSG Nat Gas Header Pipe Length HRSG Nat Gas Branch Pipe Size 2.00 in HRSG Nat Gas Branch Pipe Schedule HRSG Nat Gas Branch Pipe Length ft High Pressure Steam Piping Page 4
5 Mass Flow, per HRSG 119, lb/h Pressure at HRSG psia Temperature at HRSG F Plant Header Diameter 6.00 in Plant Header Length Plant Header Material Plant Header Thickness.28 in HRSG Leads Diameter 6.00 in HRSG Leads Length ft HRSG Leads Material HRSG Leads Thickness.28 in High Pressure Feedwater Piping High Pressure Feedwater Mass Flow, per HRSG 151, lb/h High Pressure Feedwater Pressure psia High Pressure Feedwater Temperature F High Pressure Feedwater Piping Header Diameter High Pressure Feedwater Piping Header Length ft High Pressure Feedwater Piping Header Material High Pressure Feedwater Piping Header Thickness High Pressure Feedwater Piping Leads Diameter High Pressure Feedwater Piping Leads Length ft High Pressure Feedwater Piping Leads Material High Pressure Feedwater Piping Leads Thickness Low Pressure Feedwater Piping Low Pressure Feedwater Mass Flow, per HRSG 6, lb/h Low Pressure Feedwater Pressure psia Low Pressure Feedwater Temperature F Low Pressure Feedwater Piping Header Diameter Low Pressure Feedwater Piping Header Length ft Low Pressure Feedwater Piping Header Material Low Pressure Feedwater Piping Header Thickness Low Pressure Feedwater Piping Leads Diameter Low Pressure Feedwater Piping Leads Length ft Low Pressure Feedwater Piping Leads Material Low Pressure Feedwater Piping Leads Thickness Condensate Piping Condensate Piping Header Diameter Condensate Piping Header Length ft Condensate Piping Header Material Condensate Piping Header Thickness ELECTRICAL EQUIPMENT DATA Main Power Transformer - Combustion Turbine 33, kva Unit Auxiliary Transformer - Combustion Turbine 1, kva Unit Substation Transformer 1, kva Main Power Transformer - Combustion Turbine - Quantity 1 Unit Auxiliary Transformer - Combustion Turbine - Quantity 1 Unit Substation Transformer - Combustion Turbine - Quantity 4 Non-segregated Bus Duct - CT MPT to Generator Page 5
6 Non-segregated Phase Bus Duct - Length ft Non-segregated Phase Bus Duct - CT UAT to non-seg bus ducts A Non-segregated Phase Bus Duct - Length ft Non-segregated Bus Duct Non-segregated Bus Duct, Length ft Circuit Breaker - CT, Quantity 1 Circuit Breaker - CT Generator 1, A Medium Voltage Breaker - CT UAT, Quantity 1 Medium Voltage Breaker - CT UAT A Medium Voltage Breaker - CT Starter, Quantity 1 Medium Voltage Breaker - CT Starter A Medium Voltage Breaker - BFW Pump, Quantity 0 Medium Voltage Breaker - BFW Pump.00 A Medium Voltage Breaker - Unit Substation, Quantity 2 Medium Voltage Breaker - Unit Substation A Low Voltage Breaker - Unit Substation, Quantity 2 Low Voltage Breaker - Unit Substation Low Voltage Breaker - Bus Coupler, Quantity 1 Low Voltage Breaker - Bus Coupler Low Voltage Breaker - Power Centers, Quantity 2 Low Voltage Breaker - Power Centers A Low Voltage Breaker - Motor Control Center, Quantity 2 Low Voltage Breaker - Motor Control Center A Switchyard Voltage kv Page 6
Introducing the TM /
Introducing the TM2500+ 8 / What s New? LM2500 PLUS gas turbine Up to 30% more power! Two-trailer design 75% reduction in footprint Improved interconnection design Faster installation and set-up 9 / 31%
More informationMCU Steam Outlet Pressure 420 psig (29.5 kg/cm 2 ) MCU Steam Outlet Temperature 571 F (299 C). MCU Net Steam Production
MCU Package Deliverable Outputs Expected electrical power and steam generation with two turbines operating at an ambient temperature of 59 F (15 C), standard atmospheric pressure at sea level, 2" (50.8
More informationIN-STOCK INVENTORY O-TYPE WATERTUBE BOILER O-TYPE BOILER - UP TO 75,000 PPH SPECIFICATIONS SCOPE OF SUPPLY
O-TYPE WATERTUBE BOILER F OLLOW A L E ADE R O-TYPE BOILER - UP TO 75,000 PPH Model No.: VS-4-57 Saturated Unit National Board No.: Available upon request Unit Condition: New Unit Type: O-Type Watertube
More information93 MWe natural gas fired Combined Cycle Power Plant
93 MWe natural gas fired Combined Cycle Power Plant 1. Power Plant General Description This is a Combined Cycle Cogeneration Power Plant (CCCPP) located in (Milan) able to supply about 30 t/h of surplus
More informationDRAFT APPENDIX G. PERFORMANCE CHARACTERISTICS FOR DUAL FUEL CTS
APPENDIX G. PERFORMANCE CHARACTERISTICS FOR DUAL FUEL CTS The tables which follow show key performance characteristics for the GE 7FA CT in a 2x1 CC configuration, the GE 7FA CT in SC configuration, the
More information27 MW Combined Cycle Power Plant, for sale:
TUBA Turbine GmbH Paul-Ehrlich-St.r 15 60596 Frankfurt/Germany Telefon: +49 69 69 71 61 61 Telefax: +49 69 69 71 61 41 Mobil: +49 171 75 25 838 Mail: office@tuba-turbine.de Skype: tubaturbine Internet:
More informationTECHNICAL INFORMATION
1 WORKING MACHINE WITH SOLVENT: HYDROCARBON MACHINE CAPACITY (RATIO 1:20) Lbs 40 BASKET Diameter Depth Volume Wash speed Extract speed Door opening inches 35.4 inches 21 gal 90 rpm 12 50 rpm 300 540 inches
More informationTECHNICAL INFORMATION
1 WORKING MACHINE WITH SOLVENT: HYDROCARBON MACHINE CAPACITY Lbs 60 BASKET Diameter Depth Volume Wash speed Extract speed Door opening inches 39.4 inches 25.2 gal 132 rpm 12 50 rpm 300 540 inches 20 SOLVENT
More informationANNEX A-5 GAS TURBINE JET ENGINE EXPANDER TURBINE STEAM TURBINE GENERATOR
ANNEX A-5 UNITS IN COMBINED CYCLE or CO-GENERATION BLOCKS INDEX TO SYSTEM/COMPONENT CAUSE CODES Inlet Air System and Compressors 5000-5039 Fuel, Ignition and Combustion Systems 5040-5079 Turbine 5080-5099
More informationAppendix B8 Combined Cycle Cogeneration Block Cause Codes
Appendix B8 Combined Cycle Cogeneration Block Cause Codes UNITS IN COMBINED CYCLE or COGENERATION BLOCKS INDEX TO SYSTEM/COMPONENT CAUSE CODES (Gas Turbine Codes 300 399 or 700 799) (Steam Turbine Codes
More informationNITIN CORPORATION 402, 4 th Floor, Bezzola Commercial Complex, Sion Trombay Road, Chembur, Mumbai , India.
NITIN CORPORATION 402, 4 th Floor, Bezzola Commercial Complex, Sion Trombay Road, Chembur, Mumbai 400071, India. WEB : www.corponit.com E MAIL : nitincorporation@yahoo.com enquiry@corponit.com PH (O) :
More informationProduct Specification
Capstone Capstone Turbine Corporation 21211 Nordhoff Street Chatsworth CA 91311 USA Telephone: (818) 734-5300 Facsimile: (818) 734-5320 Website: www.microturbine.com Product Specification Technical Specifications
More informationXQ-5200 Solar T60 Gas Turbine-Generator 5,200 ekw Iso Conditions 13.8 kv
XQ-5200 Solar T60 Gas Turbine-Generator 5,200 ekw Iso Conditions 13.8 kv XQ-5200_Specs.doc Page 1 of 11 Index 1. Overview... 3 2. Equipment... 4 3. Performance Data... 4 4. Gas Composition Requirement...
More information95 MW Wartsila Natural Gas Generator Power Plant
95 MW Wartsila Natural Gas Generator Power Plant Plant comprises of (12) 8730 KW Wartsila, 20V34SG Natural Gas Engines and ABB Alternators, Fuel: Natural Gas, Year /2009, 11 KV, 50 HZ, Complete plant with
More informationGenerator set data sheet Prime. Fuel consumption. Engine Standby rating Prime rating Continuous rating. Fuel flow
Generator set data sheet Model: Frequency: Fuel type: kw rating: Emissions level: DQLC 60 Hz Diesel 500 Standby 335 Prime 950 Continuous Exhaust emission data sheet: Sound performance data sheet: Cooling
More information50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS
R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES
More informationPORTISHEAD B POWER STATION
PORTISHEAD B POWER STATION Portishead B Statistics: Main Building (General) Overall length: 704 ft. Overall width: 186 ft. Height above ground: 138 ft. (boiler house) Height above ground: 80 ft. (turbine
More informationTM2500 & TM2500+ Mobile Gas Turbine Generator
TM2500 & TM2500+ Mobile Gas Turbine Generator December, 2008 Product Description 23-31 MW mobile gas turbine generator Easily transported by land, air, or sea 50 or 60 Hz flexibility Liquid or natural
More informationSECTION H3 TRAYMASTER SERIES DEAERATORS
SECTION H3 TRAYMASTER SERIES DEAERATORS SAMPLE SPECIFICATIONS PART 1 GENERAL... H3-12 1.1 Packaged Deaerator Specification... H3-12 PART 2 PRODUCTS... H3-12 2.1 Deaerator... H3-12 2.2 Deaerator Vessel...
More information2500 Prime 2100 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2
Generator set data sheet Model: DQLF Frequency: 60 Hz Fuel type: Diesel kw rating: 2750 Standby 2500 Prime 2100 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2 Exhaust emission data sheet:
More informationLM 6000 PC Technical Description
LM 6000 PC Technical Description Table of Contents Table of Contents... 1 1. Unit s Identity... 2 1.1 Gas Turbines Electronic Controls System... 2 1.2 Main Equipment Technical Data... 2 2. Technical Description
More informationUltra-low sulphur diesel (15 ppm sulphur)
Generator set data sheet Model: Frequency: Fuel type: kw rating: DQLH 60 Hz Ultra-low sulphur diesel (15 ppm sulphur) 2750 Standby 2500 Prime 2100 Continuous Emissions level: EPA Stationary non-emergency
More informationIMM CONE CT Study Results
IMM CONE CT Study Results MIC Special Session: Quadrennial Review June 1, 2018 Joe Bowring Raymond Pasteris Objective of Study Develop an independent determination of CONE CT revenue requirements for the
More informationTechnologies & Economics
Panos Konstantin Power and Energy Systems Technologies & Economics Case Study Cycle Simulation CCT Notes: 1. Cells with black characters include inputs 2. Cells with red characters include formulas 3.
More informationCXVT Engineering Data
CXVT Engineering Data H Access Door Both Ends W End Elevation: CXVT Units CXVT-x-1224-x and CXVT-x-1426-x CXVT-x-2424-x and CXVT-x-2826-x 1. Model number denotes R-717 capacity in evaporator tons at a
More information2500 Prime 2200 Continuous
Generator set data sheet Model: Frequency: Fuel type: kw rating: DQLD 60 Hz Diesel 2750 Standby 2500 Prime 2200 Continuous Exhaust emission data sheet: Sound performance data sheet: Cooling performance
More information1135 Prime 1000 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2
Generator set data sheet Model: Frequency: Fuel type: kw : DQGAE 60 Hz Diesel 1250 1135 1000 Emissions level: EPA NSPS Stationary Emergency Tier 2 Exhaust emission data sheet: Exhaust emission compliance
More informationWest Campus Power Plant
West Campus Power Plant Tabular Report The University of Iowa Iowa City, IA Final August 2009 Executive Summary As new facilities are located on the West Campus, the utility load increases and additional
More informationEngineers Ireland Site Visit 23 rd March 2010
Whitegate Independent Power Plant CER Site Visit 24 th October 2008 CER Site Visit 24 th October 2008nt Engineers Ireland Site Visit 23 rd March 2010 Agenda Presentation of project and progress to date.
More informationCMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES
DIESEL GENERATOR SET FEATURES Image shown may not reflect actual package. FUEL/EMISSIONS STRATEGY Low fuel consumption SINGLE-SOURCE SUPPLIER Designed and built at Caterpillar ISO certified facilities
More informationTECHNICAL INFORMATION F25 AS LT3 12/2011 / B 1
F25 AS LT3 1 WORKING MACHINE WITH SOLVENT HYDROCARBON MACHINE CAPACITY 25 Kg 55 60 Lbs BASKET Diameter 1000 mm 39.4 inches Depth 640 mm 25.2 inches Volume 500 Lt 14.1 cu.ft Wash speed 20 50 rpm Extract
More informationSECTION H4 BOILERMATE DEAERATORS
SAMPLE SPECIFICATIONS PART 1 SECTION H4 BOILERMATE DEAERATORS GENERAL...H4-14 1.01 General...H4-14 PART 2 PRODUCTS...H4-14 2.01 Hardware...H4-14 A. Deaerator...H4-14 B. Make Up Valve and Controller...H4-15
More informationProduct Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons
Product Data Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 1 Nominal Tons The 50XCA single-package cooling units with integral air-cooled condensers
More informationKTA50 Land Based Drilling Power Modules
KTA50 Land Based Drilling Power Modules Description Cummins Land Based Drilling Power Modules are designed and tested based on oil field customer requirements to provide optimum performance, reliability,
More informationSan Joaquin Valley Unified Air Pollution Control District
Best Available Control Technology (BACT) Guideline 2.1.1* Last Update 3/17/1997 Soil Remediation Operation - Thermal Oxidizer NOx 1. Natural gas with low NOx burner 2. Water injection (valid only for vapor
More informationIMM CONE CT Study Results
IMM CONE CT Study Results MIC Special Session: Quadrennial Review June 22, 2018 Joe Bowring Raymond Pasteris Objective of Study Develop an independent determination of CONE CT revenue requirements for
More informationTECHNICAL INFORMATION HXL 8015 S 11/2011 / 730-C 1
1 WORKING MACHINE WITH SOLVENT HYDROCARBON MACHINE CAPACITY 15 Kg 35 Lbs BASKET Diameter 800 mm 31.5 inches Depth 560 mm 22 inches Volume 285 Lt 10.1 cu.ft Wash speed 20 55 rpm Extract speed 300 500 rpm
More informationPrecision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz
Precision Cooling For Business-Critical Continuity Liebert CW System Design Manual - 26-181kW, 50 & 60Hz TABLE OF CONTENTS LIEBERT CW MODEL NUMBER NOMENCLATURE....................................1 1.0
More informationSee Note. 100% of rated load. Mechanical efficiency ISO3046/1 2,4,7 35.2% 34.8% 34.1% Electrical efficiency ISO3046/1 2,4,6,7 33.7% 33.4% 32.
Generator set data sheet 1000 kw (1250 kva) Standby Model: C1000 N6 Frequency: 60 Hz Fuel type: Natural gas MI 50 + Emissions NOx: 1.0 g/hp-hr LT water inlet temp: 50 C (122 F) HT water outlet temp: 90
More informationSee Note. 100% of rated load
Generator set data sheet 1250 kw (1563 kva) Standby Model: C1250 N6 Frequency: 60 Hz Fuel type: Natural gas MI 69 + Emissions NOx: 1.0 g/hp-hr LT water inlet temp: 50 C (122 F) HT water outlet temp: 90
More informationProduct Specification
Phone: (818) 734-5300 Fax: (818) 734-5320 Web: www.capstoneturbine.com Product Specification Model C65 Capstone MicroTurbine 460044 Rev D (May 2013) Page 1 of 15 Capstone Turbine Corporation 21211 Nordhoff
More informationA214396F78F5E4B92DB85A8D15EFBBC #2.ECT0223b.xls
From: To: Cc: Bcc: Subject: Date: Attachments: Aiken, Sam Larua Fanelli Fitzsimmons, Casey McHugh, Sean
More informationSAMPLE SPECIFICATIONS
SAMPLE SPECIFICATIONS CONTENTS PART 1 GENERAL...H1a-12 1.1 DEAERATOR SPECIFICATION...H1a-12 PART 2 PRODUCTS...H1a-12 2.1 HARDWARE...H1a-12 A. Deaerator...H1a-12 B. Make Up Valve and Controller...H1a-14
More informationTECHNICAL INFORMATION
03/2004 648-A 1 WORKING MACHINE WITH SOLVENT: PERCLORETHILENE MACHINE CAPACITY (RATIO 1:20) Lbs 55 60 BASKET Diameter Depth Volume Wash speed without Inverter Extract speed without Inverter Wash speed
More informationSee Note. 100% of rated load
Generator set data sheet 1160 kw Continuous Model: Frequency: C1160 N5C 50 Hz Fuel type: Natural gas MI 78 + Emissions NOx: 500 mg/nm 3 LT water inlet temp: HT water outlet temp: 50 C (122 F) 95 C (203
More informationSee Note. 100% of rated load
Generator set data sheet 1400 kw Continuous Model: C1400 N6C Frequency: 60 Hz Fuel type: Natural gas MI 75 + Emissions NOx: 1.0 g/hp-hr LT water inlet temp: 50 C (122 F) HT water outlet temp: 90 C (194
More informationProduct Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm
Product Data 42BH System Fan Coil 800 to 4000 Cfm Satisfy All Your Design Requirements with Carrier s Versatile 42BH Fan Coil Unit A selection of 6 sizes covers capacities from 800 to 4000 cfm Choice of
More informationWET COMPRESSION. What it Is Not. What it Is. Is not traditional inlet air cooling, like a fogger or a chiller
IGTI 2011 June 8 th, 2011 What it Is 8 to 25% (~12% 7EA) Power Augmentation at any wet bulb temperature above 45 F Complimentary Technology -used in series w/ inlet cooling & other GT upgrades Technology
More informationGEN SET PERFORMANCE DATA [24Z06603]
GEN SET PERFORMANCE DATA [24Z06603] Sales Model: 3512 DITA Combustion: DI Engine Power: 1150 W/O F 1,662 HP Manifold Type: DRY Speed: 1,800 RPM Governor Type: WDWRD Aspr: TA After Cooler: JWAC After Cooler
More informationAppendix A. Cooling Coil
Appendix A COILS FOR RUN-AROUND HEAT RECOVERY SYSTEM Cooling Coil Model number D--B45 Coil Information Tag Exhaust Wint Actual airflow Quantity System type 1 Chilled Water Entering dry bulb Entering wet
More informationGEN SET PERFORMANCE DATA [23Z03937] JULY 16, 2015
Page 1 of 9 SET PERFORMANCE DATA [23Z03937] JULY 16, 2015 For Help Desk Phone Numbers Click here Performance Number: TM3264 Change Level: 10 Sales Model: 3508 DITA Combustion: DI Aspr: TA Engine Power:
More information220 to Volts or 1800 RPM
Diesel Generator Set Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications
More information(With the possibility of conversion to HFO firing)
Ref.-No.: GT - 346 Entire 230 MWel Combined Cycle Power Plant -1 x 155 MWel V94.2 Gas Turbine Generator with HRSG - 1 x 75 MWel Steam Turbine Generator (With the possibility of conversion to HFO firing)
More information220 to Volts or 1800 RPM
Diesel Generator Set Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications
More information1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications Generator Set
More informationNITIN CORPORATION 402, 4 th Floor, Bezzola Commercial Complex, Sion Trombay Road, Chembur, Mumbai , India.
NITIN CORPORATION 402, 4 th Floor, Bezzola Commercial Complex, Sion Trombay Road, Chembur, Mumbai 400071, India. WEB: www.corponit.com E MAIL: enquiry@corponit.com nitincorporation@yahoo.com FAX : +91-22
More informationEngine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration
3512C Generator Set Electric Power Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
More informationGE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work
GE Consumer & Industrial Power Protection New SecoGear 12-24kV GE imagination at work General SecoGear metal-clad switchgear is designed and manufactured with advance technology and has been comprehensively
More informationTECHNICAL INFORMATION
1 WORKING MACHINE WITH SOLVENT PERCHLORETHYLENE MACHINE CAPACITY (RATIO 1:20) Lbs 40 BASKET Diameter Depth Volume Wash speed Extract speed Door opening inches 35.4 inches 21 cu-ft 12 rpm 40 rpm 400 inches
More informationGEN SET PERFORMANCE DATA [HCC PREFIX]
SET PERFORMANCE DATA [HCC PREFIX] Sales Model: 3306 SINA Combustion: SI Aspr: NA Engine Power: 85 W/O F 126 HP Manifold Type: WET Speed: 1,800 RPM Governor Type: PSG After Cooler: After Cooler Temp(F):
More information30,668 MWe POWER PLANT (7 x TBG 632 V 16 DEUTZ + 1 x TCG 2032 V16 MWM ENGINES) ON SALE. From OWNER
30,668 MWe POWER PLANT (7 x TBG 632 V 16 DEUTZ + 1 x TCG 2032 V16 MWM ENGINES) ON SALE From OWNER DESCRIPTION OF THE INSTALLATION The plant consists of seven DEUTZ (MWM) engines, model TBG 632 V 16; one
More information220 to volts. Electronic unit injection
Generator Set Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications
More informationCENTRIFUGAL CHILLER TECHNICAL DATA SHEET Job Name: Mt Healthy Junior Senior HS Date: 6/25/2009 Version: 06.12 Submitted By: Mary Wilking Unit Description: McQuay Model Number: WSC100MBJ72R/E4212-CE-3**/C3612-BLYY-2*****/R134-BAABM
More information12,78 779, Bore , ,22 Compression ratio. 18,1:1 Wet weight. Engine incl. cooling system, air filtration system, and frame
General Inline four stroke diesel engine with direct injection. Rotation direction, anticlockwise viewed towards flywheel. Turbocharged Number of cylinders 6 Displacement, total Firing order in 3 12,78
More informationGeneral In-line four stroke diesel engine with direct injection. Rotation direction, anti-clockwise viewed towards flywheel
Important This Technical Data Sheet and the corresponding Installation Instructions provide important information to ensure the installed engine will operate according to the design specification in the
More informationTECHNICAL INFORMATION HXL8018S-K 11/2012 / 733-B 1
HXL8018S-K 1 WORKING MACHINE WITH SOLVENT HYDROCARBON / GREEN EARTH / SOLVON K4 MACHINE CAPACITY 18 Kg 40 Lbs BASKET Diameter 900 mm 35.4 inches Depth 535 mm 21 inches Volume 340 Lt 12 cu.ft Wash speed
More information4,76 290,7 Firing order Bore
General In-line four stroke diesel engine with direct injection. Rotation direction, anti-clockwise viewed towards flywheel. Turbocharged Number of cylinders 4 Displacement, total litre in 3 4,76 29,7
More informationNOMENCLATURE WATER COOLED PACKAGE UNITS GENERAL DESCRIPTION. Cleanable Shell and Tube Condenser. Scroll Compressor(s)
NOMENCLATURE Product that perform By people who care 6 WCP S 640 B Q P Blank 50Hz 6 60Hz Blank P R22 R407c Water Cooled Packaged Blank Rotary S Scroll Compressor Model Code Blank Standard Q Special B Floor
More informationVoltage 220 to or 1800 RPM
A TA Diesel Generator Set Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications
More information220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.
Generator Set Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications
More informationOmegaAir Series Dedicated Outside Air Systems (DOAS) Engineering Guide
Series Dedicated Outside Air Systems (DOAS) Engineering Guide Effective September 2017 Vertical and Horizontal Water-Cooled and Air-Cooled Contents Product Features...3 Options...4 Air-Cooled Indoor Ducted
More information3412C Generator Set Electric Power. Specifications. Benefits and Features
Generator Set Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications
More informationCat 3516B Diesel Generator Sets
Cat 3516B Diesel Generator Sets Bore mm (in) 170 (6.69) Stroke mm (in) 190 (7.48) Displacement L (in 3 ) 69 (4210.64) Compression Ratio 14.0:1 Aspiration TA Fuel System EUI Governor Type ADEM A3 Image
More informationCat C32 Diesel Generator Sets
Cat C32 Diesel Generator Sets Bore 145 (5.7) Stroke 162 (6.4) Displacement L (in 3 ) 32.1 (1952.76) Compression Ratio 15.0:1 Aspiration TA Fuel System EUI Governor Type ADEM A4 Image shown may not reflect
More informationC32 ACERT Generator Set Electric Power
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Generator Set Specifications
More informationCat 3516B Diesel Generator Sets
Cat 3516B Diesel Generator Sets Bore mm (in) 170 (6.69) Stroke mm (in) 215 (8.46) Displacement L (in 3 ) 78 (4764.73) Compression Ratio 15.5:1 Aspiration TA Fuel System EUI Governor Type ADEM A3 Image
More informationCat 3516B Diesel Generator Sets
Cat 3516B Diesel Generator Sets Bore mm (in) 170 (6.69) Stroke mm (in) 190 (7.48) Displacement L (in 3 ) 69 (4210.64) Compression Ratio 14.0:1 Aspiration TA Fuel System EUI Governor Type ADEM A3 Image
More informationSee Note. 100% of rated load
Generator set data sheet 2000 kw Continuous Model: Frequency: Fuel type: Emissions NOx: LT water inlet temp: HT water outlet temp: C2000 N6C 60 Hz Low BTU 0.5 g/hp-h 50 C (122 F) 92 C (198 F) Measured
More information1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications Generator Set
More informationSee Note. 100% of rated load
Generator set data sheet 2000 kw Continuous Model: C2000 N6C Frequency: 60 Hz Fuel type: Natural gas MI 76 + Emissions NOx: 0.5 g/hp-h LT water inlet temp: 50 C (122 F) HT water outlet temp: 92 C (198
More informationDIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS
Product Specifications DIRECT EXPANSION COMMERCIAL PACKAGED AIR HANDLING UNITS, 6 25 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Multi position design for horizontal or vertical installation without
More informationCat C32 Diesel Generator Sets
Cat C32 Diesel Generator Sets Bore 145 (5.7) Stroke 162 (6.4) Displacement L (in 3 ) 32.1 (1959) Compression Ratio 14.0:1 Aspiration TA Fuel System EUI Governor Type ADEM A4 Image shown may not reflect
More informationSee Note. 100% of rated load 2,4,6, (17.73)
Generator set data sheet 2000 kw Continuous Model: Frequency: C2000 N5CB 50 Hz Fuel type: Natural gas MI 70 + Emissions NOx: 350 mg/nm 3 LT water inlet temp: HT water outlet temp: 40 C (104 F) 92 C (198
More informationA Division of Nailor International Inc. ECONOMY AIR HANDLERS
A Division of Nailor International Inc. MODEL : ECONOMY AIR HANDLERS Thermal Model Standard Specification MODEL 800-4000 CFM AIR HANDLERS Description Model air handlers are designed for efficient and economical
More informationSpecifications. 3406C Generator Set Electric Power
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications Generator Set
More informationModel CBEX Elite HP
Model CBEX Elite 100-800 HP TABLE OF CONTENTS FEATURES AND BENEFITS.....................................................3 PRODUCT OFFERING.........................................................3 DIMENSIONS
More informationPRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts
DIESEL GENERATOR SET PRIME 400 ekw 500 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
More informationCAT PAU 99(2) SUPERSEDES CAT.NO SARAVEL PACKAGED AIR CONDITIONING UNITS
CAT PAU 99(2) SUPERSEDES CAT.NO.200-95 SARAVEL PACKAGED AIR CONDITIONING UNITS TABLE OF CONTENTS Introduction...3 Physical Data..... 4 Selection Procedure....5-7 Water Cooled Packaged Unit Ratings....
More information220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)
Generator Set Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Specifications
More informationCat C32 Diesel Generator Sets
Cat C32 Diesel Generator Sets Bore mm (in) 145 (5.7) Stroke mm (in) 162 (6.4) Displacement L (in 3 ) 32.1 (1959) Compression Ratio 15.0:1 Aspiration TA Fuel System EUI Governor Type ADEM A4 Image shown
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationabc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.
CPD7948/075 Specification Oil-Free, Air Cooled, Rotary Screw Compressors - Dryclon Range Models D75, D90, D110, D132, D150 (50Hz) D55, D75, D90, D110, D150 (60Hz) COMPRESSOR PACKAGE An enclosed two stage
More informationMARINE ENGINE PERFORMANCE DATA [T2P PREFIX]
MARINE PERFORMANCE DATA [T2P PREFIX] Sales Model: C18 DITA Combustion: DI Aspr: TA Engine Power: 715 HP Speed: 2,100 After Cooler: SWAC Manifold Type: W/C Governor Type: After Cooler Temp(F): -- Turbo
More informationCat C Diesel Generator Sets
Cat C175-16 Diesel Generator Sets Image shown may not refl ect actual confi guration Bore 175 (6.89) Stroke 220 (8.66) Displacement L (in 3 ) 84.7 (6456.31) Compression Ratio 16.7:1 Aspiration TA Fuel
More informationEngine incl. cooling system and air filtration system Engine incl. cooling system, air filtration system, and frame. Standby Power
20110216 General Inline four stroke diesel engine with direct injection. Rotation direction, anticlockwise viewed towards flywheel. Turbocharged Number of cylinders 6 Displacement, total Firing order in
More informationFeed System. Oil Volume with Filter 14 qt 13.3 L. Maximum Angle of Continuous Operation. 30 deg. Liquid. Cooling Medium
Brush Chippers > BC1500 BC1500 Specs General Dimensions and Weights Length - Feed Table Up, Tongue In Length - Table Down, Tongue Extended 179" 454.7 cm 217" 551.2 cm Width 86" 218.4 cm Height 104" 264.2
More information: Nubaria Module III - Egypt (2x250MW GE gas turbines frame 9 FA)
103956-MEC-CMOS-E-2000 Gas Turbine Maintenance Engineer Holds a B. Sc. in Mechanical Power Engineering and has over 14 years hands-on experience working in construction, maintenance, operation, commissioning
More informationCat 3516B Diesel Generator Sets
Cat 3516B Diesel Generator Sets Image shown may not refl ect actual confi guration Bore 170 (6.69) Stroke 215 (8.46) Displacement L (in 3 ) 78.08 (4764.73 ) Compression Ratio 15.5:1 Aspiration TA Fuel
More informationPERFORMANCE DATA [1HZ00788] JULY 09, 2014 For Help Desk Phone Numbers Click here
PERFORMANCE DATA [1HZ00788] JULY 09, 2014 For Help Desk Phone Numbers Click here Perf No: DM4683 Change Level: 02 General Heat Rejection Emissions Regulatory Altitude Derate Cross Reference General Notes
More informationBAC / BHC Product Specifications
COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves
More information