15-kV Live Terminal 200 Amp Mini-Switch Source-Isolated Pad-Mounted Switchgear 40 Amp (Max) Arc-Strangler NX Fuses

Size: px
Start display at page:

Download "15-kV Live Terminal 200 Amp Mini-Switch Source-Isolated Pad-Mounted Switchgear 40 Amp (Max) Arc-Strangler NX Fuses"

Transcription

1 Page Heavy duty 11-gauge steel enclosure is all-welded construction for long life Door safety barrier removal instructions Safety latches on the door safety barriers, front and rear, are insulating and require a positive action to remove the safety barrier Clear-polycarbonate door safety barriers (front and rear) allows visual inspection without removal Corrosion proof nameplate is located to provide easy access for the operator Danger Keep Out! Hazardous Voltage Nontracking self-scouring ELRIM cycloaliphatic epoxy thru-bushings and insulators Stainless steel hinges are welded to the door & the enclosure pins are standard arrier lift handles are insulating and keyed to prevent rotation Door-holder rods are stainless steel and hold the door open 100 degrees or 140 degrees Ground lugs on each wall of the elbow compartment accept #6 - #2/0 ground cable Superlife finish includes phosphatizing, rust-inhibiting epoxy primer and Pad-Mount Green (Munsell 7GY 3.29/1.5) polyurethane top coat - over 5 mils dry ENCLOSURE OPTIONS: 1) #5052H32 luminum 2) 12-gauge #304L Stainless Steel

2 Page Cross-kinked roof prevents standing moisture 300 mp copper transfer bus for source isolation Field-Proven Components including Elliott thru-bushings specifically designed for "in-air" operation gives you long-term reliable service Fuse mountings accept rc Strangler Switchblades and/or rc-strangler Current Limiting fuses Standard Cable Training means quick, economical installation and assures proper operation for the life of the equipment Tamper-Resistant Enclosure meets National and Regional Enclosure Integrity Standards and virtually eliminates the entrance of airborne contamination to reduce maintenance Co-ordinated padlock and penta-head or optional hex-head bolt (top and bottom) provides bolted door security with visual confirmation by supervisory personnel. Security bolt is made captive with a stainless steel washer compressed to an oval shape to severely discourage removal. Overlapping door and enclosure flanges - with other features - provide tamper resistance to meet national and regional standards Fuses compartment label is visible with doors closed 300 mp copper bus has rounded corners and is de-burred for corona-free operation In-ir Insulation eliminates leaking or contamination of insulating medium for long trouble-free operation In-ir Visibility allows visual inspection of all components without the inconvenience or expense associated with equipment which must be de-energized for inspection Removable lift provisions with blind holes for tamper resistance Nonferrous hardware for long life Glass reinforced barriers meet NEM GPO-3 Standards In-ir ccessibility means every connection may be checked and tightened using hot stick tools without de-energizing the equipment Open bottom and terminal arrangement allows easy cable installation and maintenance

3 Page Selecting Switchgear The switchgear shown in the circuit diagrams below is rated 8.3/14.4 kv Grounded Wye Maximum Design. Dimension drawings showing each design can be found on pages 4 through 11 of this bulletin. The continuous-current rating of the Thru-bushings is 200 amperes with an eight-hour overload rating of 300 amperes. us bar terminals are copper, rated 300 amperes continuous-current. Thru-bushings and insulators are cycloaliphatic epoxy with square edge skirts and extra creep for superior contamination resistance. Four ground terminals, which accept #6 through #2/0 cable, are included and are installed as shown by the drawings. rc-strangler Switchblades are interchangeable with rc Strangler Fuses (Code 1 switchblades interchange with Code 1 fuses and Code 2 switchblades interchange with Code 2 fuses). s a result, switchblades or fuses can be installed in any combination for every design shown in this bulletin. rc-strangler Switchblades are rated to make and break 200 amperes. Maximum fuse size is 40 amperes utilizing Eaton s Cooper Power Systems rc-strangler NX Current- Limiting Fuses. Switchblade information, fuse information and available fuse sizes can be found on pages 15 and 16 of this bulletin. These Mini-Switches may be ordered with or without rc Strangler Switchblades and/or rc-strangler Fuses. The Typical Specification on pages 12, 13 and 14 describe the design, construction and available alternate switch and fuse options. EPMS S-EL2-T/1 EPMS S-EL2-T/2 EPMS S-EL2-1/CM4 EPMS S-EL2-2/CM5 EPMS S-EL2-T/1 EPMS S-EL2-T/2 EPMS S-EL2-1 EPMS S-EL2-2

4 Page Cable Training and nchor olt Locations Front View Rear View Enclosure 2.25" X 2.25" Galv. Square Washer Ø.5" nchor olts 1.5" Concrete Pad lternate #1 Enclosure Elliott nchor racket # Ø.5" nchor olts 1.5" Concrete Pad Section and Typical Pad Dimensions lternate #2 Catalog Number Switchblade/Fuse Mounting Dim. EPMS S-EL2-T/1 EPMS S-EL2-T/2 When additional cable terminating space is required, a 48 or 54 high enclosure can be supplied to increase cable terminating space by 6 or 12. To order a 48 high enclosure, suffix the catalog number -48H. To order a 54 high enclosure, suffix the catalog number -54H. 8.3 kv (Code 1) 1.5 to 40 mp 15.5 kv (Code 2) 1.5 to 40 mp

5 Page Three-Phase Two Ways Per Phase 200 mp Elliott ir-insulated Thru-ushings 8.3/14.4 kv Grounded Wye Max Design 95 kv IL 30" "us" Label is Visible with Door Closed 30" "Fuses" Label is Visible with Door Closed C Provision for Padlock and Security olt, Top and ottom 42" C 7.5" 7.5" 7.5" 7.5" Front View Rear View 30" 42" 26" 28" ottom Open 2" 8.5" 42" 42" 34" 200 mp Elliott Thru-ushing Door Safety arrier Front and Rear Equipment Plate 7.5" 7.5" 8.5" GPO-3 arriers 40" 38" Projected Centerline of Cables "" ø 0.75" Typical Two Ground Provisions Each Side Section Section Catalog Number Switchblade/Fuse Mounting Dim. EPMS S-EL2-T/1 EPMS S-EL2-T/2 When additional cable terminating space is required, a 48 or 54 high enclosure can be supplied to increase cable terminating space by 6 or 12. To order a 48 high enclosure, suffix the catalog number -48H. To order a 54 high enclosure, suffix the catalog number -54H. 8.3 kv (Code 1) 1.5 to 40 mp 15.5 kv (Code 2) 1.5 to 40 mp

6 Page Cable Training and nchor olt Locations 30" 30" 42" "" "" 7.5" 7.5" 6" Min. 7.5" 7.5" 6" Min. Front View Rear View Enclosure 2.25" X 2.25" Galv. Square Washer Ø.5" nchor olts 1.5" Concrete Pad lternate #1 Enclosure Elliott nchor racket # Ø.5" nchor olts 1.5" Concrete Pad Section and Typical Pad Dimensions lternate #2 Catalog Number Switchblade/Fuse Mounting Dim. EPMS S-EL2-1/CM4 EPMS S-EL2-2/CM5 When additional cable terminating space is required, a 48 or 54 high enclosure can be supplied to increase cable terminating space by 6 or 12. To order a 48 high enclosure, suffix the catalog number -48H. To order a 54 high enclosure, suffix the catalog number -54H. 8.3 kv (Code 1) rc-strangler /8.3 kv (Code 4) 1.5 to 40 mp Clip Mounted CL Fuse 15.5 kv (Code 1) rc-strangler /8.3 kv (Code 5) 1.5 to 140 mp Clip Mounted CL Fuse

7 Page Three-Phase Two Ways Per Phase 200 mp Elliott ir Insulated Thru-ushings 8.3/14.4 kv Grounded Wye Max Design 95 kv IL Front View Rear View Section Section Catalog Number Switchblade/Fuse Mounting Dim. EPMS S-EL2-1/CM4 EPMS S-EL2-2/CM5 When additional cable terminating space is required, a 48 or 54 high enclosure can be supplied to increase cable terminating space by 6 or 12. To order a 48 high enclosure, suffix the catalog number -48H. To order a 54 high enclosure, suffix the catalog number -54H. 8.3 kv (Code 1) rc-strangler /8.3 kv (Code 4) 1.5 to 40 mp Clip Mounted CL Fuse 15.5 kv (Code 1) rc-strangler /8.3 kv (Code 5) 1.5 to 140 mp Clip Mounted CL Fuse

8 Page Cable Training and nchor olt Locations Front View Rear View Enclosure 2.25" X 2.25" Galv. Square Washer Ø.5" nchor olts 1.5" Concrete Pad lternate #1 Enclosure Elliott nchor racket # Ø.5" nchor olts 1.5" Concrete Pad Section and Typical Pad Dimensions lternate #2 Catalog Number Switchblade/Fuse Mounting Dim. EPMS S-EL2-T/1 EPMS S-EL2-T/2 When additional cable terminating space is required, a 48 or 54 high enclosure can be supplied to increase cable terminating space by 6 or 12. To order a 48 high enclosure, suffix the catalog number -48H. To order a 54 high enclosure, suffix the catalog number -54H. 8.3 kv (Code 1) 1.5 to 40 mp 15.5 kv (Code 2) 1.5 to 40 mp

9 Page Three-Phase Four Ways Per Phase 200 mp Elliott ir-insulated Thru-ushings 8.3/14.4 kv Grounded Wye Max Design 95 kv IL "us" Label is Visible with Door Closed 48" 48" "Fuses" Label is Visible with Door Closed Provision for Padlock and Security olt, Top and ottom C C 48" 6.5" 6.5" 6.5" 6.5" 3.25" 3.25" C C 6.5" 6.5" 6.5" 6.5" 3.25" 3.25" Front View Rear View Section Section Catalog Number Switchblade/Fuse Mounting Dim. EPMS S-EL2-T/1 EPMS S-EL2-T/2 When additional cable terminating space is required, a 48 or 54 high enclosure can be supplied to increase cable terminating space by 6 or 12. To order a 48 high enclosure, suffix the catalog number -48H. To order a 54 high enclosure, suffix the catalog number -54H. 8.3 kv (Code 1) 1.5 to 40 mp 15.5 kv (Code 2) 1.5 to 40 mp

10 Page Cable Training and nchor olt Locations Front View Rear View Enclosure 2.25" X 2.25" Galv. Square Washer Ø.5" nchor olts 1.5" Concrete Pad lternate #1 Enclosure Elliott nchor racket # Ø.5" nchor olts 1.5" Concrete Pad Section and Typical Pad Dimensions lternate #2 Catalog Number Switchblade/Fuse Mounting Dim. EPMS S-EL2-1 EPMS S-EL2-2 When additional cable terminating space is required, a 48 or 54 high enclosure can be supplied to increase cable terminating space by 6 or 12. To order a 48 high enclosure, suffix the catalog number -48H. To order a 54 high enclosure, suffix the catalog number -54H. 8.3 kv (Code 1) 1.5 to 40 mp 15.5 kv (Code 2) 1.5 to 40 mp

11 Page Three-Phase Four Ways Per Phase 200 mp Elliott ir-insulated Thru-ushings 8.3/14.4 kv Grounded Wye Max Design 95 kv IL Front View Rear View Section Section Catalog Number Switchblade/Fuse Mounting Dim. EPMS S-EL2-1 EPMS S-EL2-2 When additional cable terminating space is required, a 48 or 54 high enclosure can be supplied to increase cable terminating space by 6 or 12. To order a 48 high enclosure, suffix the catalog number -48H. To order a 54 high enclosure, suffix the catalog number -54H. 8.3 kv (Code 1) 1.5 to 40 mp 15.5 kv (Code 2) 1.5 to 40 mp

12 Page Typical Specification - Page 1 of 3 General The switchgear shall be 15 kv Class, 95 kv IL, 200 ampere continuous current, suitable for use on 8.3/14.4 kv grounded wye max design systems. The switchgear shall be constructed for connection to the utility system with bolt-on cable terminals and stress-relief devices (Elastimold modular terminators, Joslyn PS terminators or equal to be supplied by the user). The switchgear shall be designed for and contain switch and fuse mountings that accept both Eaton s Cooper Power Systems rc-strangler Switchblades and s. door safety barrier shall be provided inside the door(s) as recommended in IEEE Standard C2 (National Electrical Safety Code) Rule 381G. Tamper resistance shall meet the Enclosure Security requirements of IEEE Standard C (Pad-Mounted Equipment Enclosure Integrity). Together, the tamper resistance and the door safety barrier(s) shall resist unauthorized entry, protect authorized and unauthorized persons, and provide positive safety features when installed in areas accessible to the general public. The switchgear shall be constructed for outdoor installation in areas subject to heavy precipitation and in areas with windblown contamination. The equipment shall be air-insulated and completely assembled prior to shipment. Enclosure Construction The enclosure shall be tamper-resistant, all-welded construction utilizing 11-gauge minimum sheet steel. Corner plates and braces shall be used as necessary to assure rigidity. The enclosure top shall be cross-kinked to provide watershed and rigidity. The enclosure shall be open bottom with a 1-inch flange inside, all around. The door(s) shall be furnished with a stainless steel door holder that will latch the door open 100 degrees and 140 degrees and resist accidental closing. Door(s) shall be provided with provisions for padlocking and a recessed penta-head (or hex-head) security bolt to prevent unauthorized entry (coordinated to prevent installation of the padlock until the security bolt is tightened when closing the door(s) and to prevent a wrench from operating the security bolt until the padlock is removed when opening the door(s)). The security bolt shall be made captive with a stainless steel washer compressed to an oval shape to severely discourage removal. Hinges shall be stainless steel (with stainless steel pins not less than inch diameter) and shall be welded to both the enclosure and the door(s) to maintain door alignment for the life of the equipment. The enclosure shall be nonventilated to minimize the entrance of airborne contamination, insects, rodents or reptiles. The protective finish shall include necessary grinding, cleaning and phosphatizing, two-component rustinhibiting epoxy primer and a Pad-Mount Green two-component polyurethane top coat finish (Munsell color 7GY 3.29/1.5). The primer and top coat shall be electronically monitored during application to insure proper ratio and mixing of each component. Total average thickness of paint (after curing) shall be not less than 5 mils. The protective coating shall meet the Enclosure Coating System requirements of IEEE Standard C (Pad-Mounted Equipment Enclosure Integrity). Removable lift provisions, adequate to withstand handling with normal utility equipment, shall be provided on the outside of the enclosure. Threaded openings for lift provision bolts shall be blind holes to prevent the entrance of wire or other foreign objects into the enclosure when lift provisions are removed. Switches lternate 1: Switch provisions shall be Code 1 to accept Eaton s Cooper Power Systems 200 ampere loadbreak 8.3 kv and 15.5 kv (short) rc-strangler Switchblades. When specified, switchblades shall be supplied in the switchgear. n available option is a holder for each switchblade that will allow storage (and retrieval) of the rc-strangler Switchblade with hot-line tools. Switchblade storage shall not interfere with opening or closing the door(s). lternate 2: Switch provisions shall be Code 2 to accept Eaton s Cooper Power Systems 200 ampere loadbreak 15.5 kv (long) rc-strangler Switchblades. When specified, switchblades shall be supplied in the switchgear. n available option is a holder for each switchblade that will allow storage (and retrieval) of the rc-strangler Switchblade with hot-line tools. Switchblade storage shall not interfere with opening or closing the door(s). us and Fuse Mountings us shall be copper with all burrs and sharp corners removed prior to installation. Fuse clips and/or fuse hinges shall be keyed to prevent rotation and to maintain alignment. Positive pressure shall be assured by use of stainless steel fasteners and lock washers or compression washers at all connection points. ll connections shall provide direct contact of current-carrying parts and shall not depend on current transfer through fastener thread-to-thread contact. Fuses and their blown-fuse indicators shall be visible (when the fuse compartment door(s) are open) without removal of the clearpolycarbonate door safety barrier to allow easy identification of blown fuses without de-energizing or removing the fuse from service. Electrical components shall be air-insulated and positioned to allow visual inspection of all internal connections and components without removing the clear-polycarbonate door safety barrier, de-energizing or removing the equipment from service. lternate 1: Fuse mountings shall be Mounting Code 1 to accept 1.5 amp to 40 amp (max), 8.3 kv Eaton s Cooper Power Systems rc-strangler NX current-limiting fuses. Spare-fuse storage is optional. When specified, a spare-fuse holder shall be provided for each fuse position that will allow storage (and retrieval) of the rc-strangler fuse with hot-line tools. Spare-fuse storage shall not interfere with opening or closing the doors. lternate 2: Fuse mountings shall be Mounting Code 2

13 Page Typical Specification - Page 2 of 3 to accept 1.5 amp to 40 amp (max), 15.5 kv Eaton s Cooper Power Systems rc-strangler NX current-limiting fuses. Spare-fuse storage is optional. When specified, a spare-fuse holder shall be provided for each fuse position that will allow storage (and retrieval) of the rc-strangler fuse with hot-line tools. Spare-fuse storage shall not interfere with opening or closing the doors. ushings and Terminals ushings shall be 200 ampere Elliott # T, 15 kv class (8.3 kv to ground) ir-insulated Live-Terminal Thru-ushings, 95 kv IL, for use with 8.3/14.4 kv systems. The bushings shall be pressure-molded cycloaliphatic epoxy with a 0.75-inch diameter copper conductor that is drilled and tapped inch 16UNC x 1-inch deep on both ends to provide for connection of the bus and/or live parts. Integral shielding shall be provided to eliminate partial discharge caused by off-center mounting and mounting holes that may have sharp edges or burrs. ushings shall mount in a inch diameter opening and bolt in place to allow field replacement with standard tools. The bushing mounting bolts shall be self-locking stainless steel serrated-flange hex-head bolts that cut through the enclosure protective finish to ground the integral shielding of each bushing. To assure adequate strength for apparatus support, the bushing shall withstand a minimum cantilever loading of 250 pounds for five minutes without damage. Each bushing shall be tested in free air, mounted in a grounded steel plate not less than 10 inches x 10 inches and shall meet the requirements for 15 kv devices in accordance with the test values of IEEE Standard 386 (latest revision), including 100 percent production testing. ushing-style Thru-Insulators Insulators shall be Elliott # TI, 25 kv class (15.2 kv to ground) ir-insulated ushing-style Thru-Insulators, 125 kv IL, for use with 8.3/14.4 kv or 15.2/26.3 kv systems. The insulators shall be nontracking, self-scouring, nonweathering pressure-molded cycloaliphatic epoxy with cast-in-place brass inserts. The brass inserts shall be drilled and tapped inch 16UNC x 1-inch deep to provide for connection of the bus and/or live parts. The skirts shall be square-edge design to provide 17 inches or more leakage distance for superior contamination resistance. Surface damage to insulators shall expose material of the same composition and characteristics so insulators with minor surface damage will not require replacement. The insulators shall provide adequate thermal cycle withstand to assure trouble-free field service in the most severe climatic conditions established by in-house testing and field-operating experience. Insulators shall mount in a inch diameter opening and bolt in place to allow field replacement with standard tools. To assure adequate strength for apparatus support, the insulator shall withstand a minimum cantilever loading of 600 pounds for five minutes without damage. The insulator mounting bolts shall be self-locking stainless steel serrated-flange hex-head bolts. Insulators The switch and bus insulators shall be nontracking, self-scouring, nonweathering pressure-molded cycloaliphatic epoxy with cast-in-place brass inserts. The skirts shall be square-edge design to provide 14 inches or more leakage distance for superior contamination resistance. Surface damage to insulators shall expose material of the same composition and characteristics so insulators with minor surface damage will not require replacement. The insulators shall provide adequate thermal cycle withstand to assure trouble-free field service in the most severe climatic conditions established by in-house testing and field-operating experience. The insulators shall be 15 kv class, 95 kv IL and produced by a manufacturer with ten or more years experience with cycloaliphatic epoxy. arriers Phase and ground barriers shall be provided to assure correct phase-to-phase and phase-to-ground clearances for proper operation at rated voltage. These barriers shall be glass-reinforced polyester (NEM GPO-3 class material) not less than inch thick. removable insulating barrier with a DNGER Keep Out! Hazardous voltage sign, Elliott #7203-D , shall be located inside the door(s) as recommended in Rule 381G of IEEE Standard C2 (National Electrical Safety Code). The door safety barriers shall be constructed of 0.25-inch clear-polycarbonate (Lexan or equal) and shall completely close the door opening and be provided with a non-conductive safety latch requiring a positive action to remove the barrier. Handles and other hardware extending through this door safety barrier shall be nonconductive material. Handles shall be keyed to prevent rotation for secure handling. Complete visual inspection of the internal components shall be possible without removing the door safety barrier. Grounding Provisions Four high-conductivity bronze eyebolt-type ground lugs, which accept #6 through #2/0 copper conductor, shall be installed on the inside walls of the enclosure (located on each side of each door opening in an accessible position as shown on the drawings). ccessory Equipment corrosion proof nameplate with permanent thermal transfer printing shall be installed inside one door on the switch (or bus) compartment. It shall be located at the top corner farthest from the live equipment when the door is open. The nameplate will provide Type of Equipment, Model Number, mps Continuous, kv Maximum, IL, Serial Number, Job Number, Date Manufactured and Weight of Equipment.

14 Page Typical Specification - Page 3 of 3 The enclosure shall be labeled in near proximity of the locking provisions with a pressure-sensitive vinyl label using letters not less than inch nor more than inch high. The label shall indicate the type of equipment behind the access (switch, fuses, bus, etc.). When specified, mounting provisions for distribution-class metal-oxide-varistor surge arresters shall be provided at each source-side switch terminal. When specified, four anchor-bolt brackets, Elliott # or approved equal, shall be supplied with each switchgear to provide a means of clamping the equipment to the concrete pad. Packaging Each switchgear shall be bolted to a solid-top wood pallet (to prevent the forks of a forklift truck from entering the open bottom of the equipment) to prevent hidden damage. The equipment shall be wrapped with inch thick polyethylene foam or other suitable material to minimize damage to the finish during shipment. Drawings When specified, drawings shall be furnished for each switchgear that include: 1) enclosure dimensions and location of components. 2) proposed pad dimensions and location of anchor bolts. 15-kV Thru-ushings Series (bolt in) for ir-insulated Service 200 mp Thru-ushing # T Thru-Insulator # TI

15 Page NX Hinge-Style rc-strangler Switchblade Ratings The rc-strangler loadbreaking device used on NX switchblades meets all the requirements of IEEE Standard C It has a continuous-current rating of 200 amps, its momentary and closing-in rating is 18,000 amps, and its loadbreaking ability is five operations at 200 amps at 80% power factor. t smaller current levels, more operations are possible. Two-hundred amp switchblades with integral rc-strangler loadbreaking devices are available for use in NX fuse mountings. They are completely interchangeable with NX fuses of the same code number so that, as system needs change, switches can be substituted for fuses and vice versa without any alteration to the mounting. Pullring rc-strangler Sleeve Voltage (kv) Rating Continuous and Loadbreak Current (amp) Ratings and Dimensions Description Mounting Code Number* Dimension (in.) Catalog Number lade F Short 15 kv lade F Long 15 kv lade F31 *Code number of mounting must match code number of fuse or switchblade. Switchblade Hinge NX Fuses with rc-strangler Loadbreaking Device NX current-limiting fuses up to 15.5 kv can be ordered with an integral rc-strangler loadbreaking device. These units have the same operating characteristics as the basic clip style fuse, along with loadbreaking capabilities. See Page 20 Core C Latch Spring ctuator Spring Fuse Conductor rc-strangler Sleeve Plastic ccessory Latch Replaces the Latch Spring lown-fuse Indicator utton rc-strangler loadbreaking device with optional accessory latch.

16 Page NX Fuses With rc-strangler Loadbreaking Device Features Eaton s Cooper Power Systems NX fuses with rc-strangler loadbreaking device offer: Safe loadbreaking. The rc-strangler loadbreak quickly extinguishes load-current arcs drawn between the mounting contacts and the fuse conductor during loadbreaking operation. Prevention from accidental closing. The rc-strangler loadbreaking device must be cocked before the fuse can be closed into the mounting. NEM standard hookstick operation. oth the pullring and the hinge accept the standard distribution-class hookstick. The hinge is made with a slot for the hookstick, making fuse removal from and replacement in the mounting easy. lown-fuse indication. red button is clearly visible after the fuse has operated. High-voltage warning. The big warning label (readable when the fuse is hanging open) warns personnel of possible danger. Optional latch. plastic latch that gives a positive indication that the device is armed is available as an accessory (See Page 15). Operating Principles The rc-strangler loadbreaking device is a springloaded sliding sleeve that cuts off the arc drawn between the mounting contacts and the fuse conductor when the fuse is opened while load current is flowing. pullring at the top of the fuse (for hookstick operation) and a hinge at the bottom complete the loadbreak device. The rc-strangler loadbreak is complete in itself no auxiliary loadbreaking tool is required and no additional loadbreaking switch in series is necessary. ll current magnitudes through the continuous-current rating of the fuse can be interrupted positively and safely under proper conditions. The loadbreaking assembly includes a stationary core and a sliding molded sleeve that covers the contacts on opening the hinged assembly. The sleeve is made of high-quality material that gives off small quantities of arc-quenching gases under the heat of the arc. Voltage (kv) 50,000 amps Symmetrical Interrupting Rating Rating Continuous Current (amp) Mounting Code Number* For Single and Parallel Unit Hinge Style Mountings 4.3, 5.5, and , 5.5, and (in.) Fuse Diameter (In.)** Catalog Number F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F F440 *Code number of mounting must match code number of fuse or switchblade. **ll 2 -in. diameter fuses have magniformed end fittings with stamped hinge. Description in. diameter hinged fuse 2-in. diameter hinged fuse Voltage Rating (kv) Dimensions Mounting Code Number* See Page 15 (in.) *Code number of mounting must match code number of fuse or switchblade. C (in.)

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses Page 1 2016 EPMR-35-311S-R2/ESW-CM9 Three Phase Two Ways per Phase 200 Amp 35 kv Class Eaton s CPS LRTPs 50 Amp (Max) 27 kv Clip-Mounted NX Fuse Provisions 21.1/36.6 kv Grounded Wye Max Design, 150 kv

More information

15-kV Safefront 200 Amp Source Isolated Cable Switching Station Pad-Mounted Non-Fusible

15-kV Safefront 200 Amp Source Isolated Cable Switching Station Pad-Mounted Non-Fusible ulletin Page 208 -gauge steel equipment plate is rigid for easier elbow operation Heavy-duty -gauge steel enclosure is all-welded construction for long life "Elbows" compartment label is visible with doors

More information

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses Page 1 2015 Heavy duty 11-gauge steel enclosure is all-welded construction for long life Corrosion proof nameplate is located to provide easy access for the operator Glass reinforced barriers meet NEMA

More information

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch Page 1 2015 Kinked roof prevents standing moisture Glass reinforced barriers meet NEMA GPO-3 Standards 0.625" diameter copper ground bar Elliott air-insulated bushings accept IEEE Standard inserts and

More information

15-kV Live Terminal Primary Metering Station Pad-Mounted Outdoor

15-kV Live Terminal Primary Metering Station Pad-Mounted Outdoor ulletin Page 1 2015 Cross-kinked roof prevents standing moisture Metering Transformer compartment label is visible with doors closed Heavy duty 11-gauge steel enclosure is all-welded construction for long

More information

15-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 140 Amp (Max) Clip-Mounted Current-Limiting Fuses

15-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 140 Amp (Max) Clip-Mounted Current-Limiting Fuses Page 1 2016 Heavy duty 11-gauge steel enclosure is all-welded construction for long life 200 Amp Elliott air-insulated bushing wells accept IEEE Standard inserts and elbows ushing wells may be added or

More information

25-kV Safefront Mini-Switch Phase Isolated Pad-Mounted Switchgear 125 Amp (Max) Clip-Mounted Current-Limiting Fuses

25-kV Safefront Mini-Switch Phase Isolated Pad-Mounted Switchgear 125 Amp (Max) Clip-Mounted Current-Limiting Fuses ulletin Page 1 2018 11-gauge steel equipment plate is rigid for easier elbow operation Heavy-duty 11-gauge steel enclosure is all-welded construction for long life us and fuse schematic is orange-colored

More information

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor

35-kV Safefront 200 Amp SuperWell Primary Metering Station Pad-Mounted Outdoor 35-kV Safefront 2 Amp SuperWell 5-33 Page 1 216 EPM-PMS-35-311P-R2/ESW Three Phase Two Ways per Phase 2 Amp 35 kv Class Eaton's CPS LRTPs NEMA Standard Outdoor Instrument Transformer Provisions 21.1/36.6

More information

35-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current-Limiting Fuses

35-kV Safefront Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current-Limiting Fuses Page 1 2016 Heavy duty 11-gauge steel enclosure is all-welded construction for long life 11-gauge steel equipment plate is rigid for easier elbow operation Parking stands for the upper two phases extend

More information

15-kV Safefront 200 Amp Primary Transformer Station Pad-Mounted Outdoor

15-kV Safefront 200 Amp Primary Transformer Station Pad-Mounted Outdoor 1-kV Safefront 200 mp ulletin 0-102 Page 1 2018 200 mp Elliott air-insulated bushing wells accept IEEE Standard inserts and elbows Open bottom and extra depth of elbow compartment provides space for use

More information

35-kV Safefront 200 Amp Primary Metering Station Pad-Mounted Outdoor

35-kV Safefront 200 Amp Primary Metering Station Pad-Mounted Outdoor ulletin Page 1 2016 Heavy duty 11-gauge steel enclosure is all-welded construction for long life 11-gauge steel equipment plate is rigid for easier elbow operation Upper parking stands extend 3" per IEEE

More information

15-kV Safefront 600 Amp Primary Transformer Station Pad-Mounted Outdoor

15-kV Safefront 600 Amp Primary Transformer Station Pad-Mounted Outdoor 1-kV Safefront 00 mp ulletin 0-10 Page 1 2018 00 mp air-insulated bushings accept IEEE Standard 00 mp elbows "Elbows" compartment label is visible with doors closed Parking stands are unpainted stainless

More information

15-kV Safefront 200 Amp Primary Capacitor Station Pad-Mounted Outdoor

15-kV Safefront 200 Amp Primary Capacitor Station Pad-Mounted Outdoor Page 1 2015 Heavy-duty 11-gauge steel enclosure is all-welded construction for long life Clear polycarbonate removable safety barrier separates upper and lower compartment (supplied only with internally

More information

35-kV Safefront 200 Amp SuperWell Primary Capacitor Station Pad-Mounted Outdoor

35-kV Safefront 200 Amp SuperWell Primary Capacitor Station Pad-Mounted Outdoor Page 1 2016 EPM-PCS-35-320P-R2/ESW-GCM6-2S-SA Three Phase Two Ways per Phase 200 Amp 35 kv Class Eaton's CPS LRTPs 35 kv Elliott Air-Insulated SuperWell Bushings 21.1/36.6 kv Grounded Wye Max Design, 150

More information

Bus and fuse schematic is orange-colored vinyl for high visibility

Bus and fuse schematic is orange-colored vinyl for high visibility -kv Safefront Mini-Switch 0 mp (Max) s and 0 mp (Max) s ulletin 00-0 Page 208 -gauge steel equipment plate is rigid for easier elbow operation Heavy-duty -gauge steel enclosure is all-welded construction

More information

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Equipment Connection Bus Bar, or Grounded Metal Equipment Plate F Series Mounting Holes ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric

More information

15 kv and 25 kv Thru-Bushings

15 kv and 25 kv Thru-Bushings Page 1 2001 ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric strength, dielectric loss and power factor Choice of shapes allows design innovation

More information

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 15 kv or 25 kv Separable Insulated Connector (elbow) Equipment Connection Power Cable Power Cable ELRIM Cycloaliphatic

More information

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV 200-kV BIL Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection 35 kv Separable Insulated Connector (elbow) Bus Bar or Other Component Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other

More information

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

35-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 35 kv Separable Insulated Connector (elbow) Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other

More information

25 kv Apparatus Bushings

25 kv Apparatus Bushings Page 1 2001 ELRIM Cycloaliphatic Epoxy Provides: Nontracking, self-scouring, nonweathering performance Superior dielectric strength, dielectric loss and power factor Choice of shapes allows design innovation

More information

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp

25-kV Apparatus Bushings A Series (clamp-in) for Elbow to Air-Insulated Service 200 Amp and 600 Amp Page 1 2018 Grounded Metal Equipment Plate Equipment Connection 15 kv or 25 kv Separable Insulated Connector (elbow) Grounded Metal Equipment Plate Equipment Connection Power Cable Power Cable ELRIM Cycloaliphatic

More information

ME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv

ME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv ME series dead-front fused sectionalizing enclosures MEC current limiting fusing and MEP power fusing 200 Amperes,15-25 kv ABB ME series fused sectionalizing enclosures ABB's dead-front Padmount ME series

More information

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break Part 1-GENERAL 1.1 DESCRIPTION Guide Specification Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break The switchgear shall consist of magnetically actuated solid dielectric insulated

More information

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings Page 1 Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings I. General This specification covers the design requirements for a pad-mounted capacitor

More information

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised

More information

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV

TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV Cutler Hammer SECTION PB-1A-110 PAGE 1 Replaces April, 1996 TYPE PSI/II PADMOUNT SWITCHGEAR 15KV 25KV The PSI/II Padmount is the second generation of switchgear in the PSI switchgear family. The PSI/II

More information

STANDARD SPECIFICATION FOR TYPE PLD LIVE-FRONT/DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV A. General

STANDARD SPECIFICATION FOR TYPE PLD LIVE-FRONT/DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV A. General Page 1 STANDARD SPECIFICATION FOR TYPE PLD LIVE-FRONT/DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV A. General 1. Product The pad-mounted switchgear shall be in accordance with the applicable plans, drawings,

More information

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 1. APPLICATION A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system. 2. REFERENCE STANDARDS A. The transformers supplied shall

More information

STANDARD SPECIFICATION FOR LIVE-FRONT 15KV AND 25KV PSI/II PAD-MOUNTED SWITCHGEAR

STANDARD SPECIFICATION FOR LIVE-FRONT 15KV AND 25KV PSI/II PAD-MOUNTED SWITCHGEAR STANDARD SPECIFICATION FOR LIVE-FRONT 15KV AND 25KV PSI/II PAD-MOUNTED SWITCHGEAR A. General 1. Product The pad-mounted switchgear shall be PSI/II design as manufactured by Federal Pacific and shall conform

More information

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS Originated 1/85 Revised 6/95 Revised 6/02 Revised 11/05 Revised 4/08 Revised 11/09 Revised 1/12 Revised 11/12 Revised

More information

Typical Specification

Typical Specification Engineered to Order Built to Last Typical Specification VAULT VRPFI, TWO POSITION, ROTARY PUFFER SWITCHGEAR PART 1- GENERAL 1.1 DESCRIPTION A. The switch shall consist of manually operated load interrupting,

More information

STANDARD SPECIFICATION FOR PAD-MOUNTED CAPACITOR BANKS FOR 15kV or 25kV APPLICATIONS

STANDARD SPECIFICATION FOR PAD-MOUNTED CAPACITOR BANKS FOR 15kV or 25kV APPLICATIONS A. General 1. Product The pad-mounted capacitor banks shall be in accordance with the applicable plans, drawings, and one-line diagrams and shall conform to these specifications. 2. Assembly The outdoor

More information

SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed.

SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS. D. Dead Front, loop feed design shall be employed. City of Cartersville Electric System P.O. Box 1390 320 S. Erwin St. Cartersville, GA 30120 770-387-5631 March 2006 SPECIFICATION FOR THREE-PHASE PAD MOUNT TRANSFORMERS This specification provides standardization

More information

S&C Manual PME Pad-Mounted Gear

S&C Manual PME Pad-Mounted Gear S&C Manual PME Pad-Mounted Gear Outdoor Distribution,. kv and 5 kv S&C Manual PME Pad-Mounted Gear... Featuring Elbow-Connected Encased Components. S&C Manual PME Pad-Mounted Gear brings in-air insulation,

More information

DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV

DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV TYPE PSE MANUAL DEAD-FRONT PAD-MOUNTED SWITCHGEAR 15kV 25kV Figure 1 Federal Pacific Dead-Front PSE (available as UL Listed) contains an integrated system of fuses and switches with access control features

More information

Underground Distribution Switchgear

Underground Distribution Switchgear Underground Distribution Switchgear Functional Specification Guide Functional Specification for 15 kv, 25 kv, or 35 kv Underground Distribution Switchgear 1. Scope 1.1. This specification applies to three-phase,

More information

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT PADMOUNTED SWITCHGEAR WITH VACUUM LOAD

More information

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115 CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-115 PADMOUNTED TRANSFORMERS 12kV AND DUAL VOLTAGE, RADIAL FEED STAINLESS STEEL NOVEMBER 2011 Specification:ELE_115_R1 Page

More information

Three-Phase Pole Mounted Recloser

Three-Phase Pole Mounted Recloser Three-Phase Pole Mounted Recloser Page 1 of 8 Table of Contents 1 GENERAL... 3 2 CONSTRUCTION... 3-5 3 BUSHINGS... 5 4 LINE CONNECTOR... 5 5 TOOLS....5 6 NAMEPLATES..6 7 PAINT... 6 8 EXTERNAL HARDWARE

More information

PAD-MOUNT SWITCHGEAR 15kV 25kV 35kV

PAD-MOUNT SWITCHGEAR 15kV 25kV 35kV PAGE 1 TYPE PSI PAD-MOUNT SWITCHGEAR 15kV 25kV 35kV INSTRUCTIONS For Installation and Operation INTRODUCTION... 1 Receiving... 1 Handling... 1 Storage... 1 GENERAL DESCRIPTION... 1 SAFETY FEATURES... 1

More information

A. Submit manufacturer's literature and technical data before starting work.

A. Submit manufacturer's literature and technical data before starting work. SECTION 16425 SWITCHBOARD PART 1 GENERAL 1.01 SUMMARY A. Related Section: 1. 16450 - Grounding. 1.02 SUBMITTALS A. Submit manufacturer's literature and technical data before starting work. B. Submit Shop

More information

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER Solid Dielectric Load Break Switch SPECIFICATION 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT PADMOUNTED VACUUM LOAD INTERRUPTING

More information

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak Powergrid Solution s Metal Enclosed Switchgear has many different customizable options and configurations. Customers

More information

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position LET S BE PACIFIC November 0 Volume Number 5 ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position Federal Pacific has the capability to engineer, fabricate and assemble

More information

NX indoor current-limiting fuses

NX indoor current-limiting fuses Fusing Equipment Catalog Data CA132049EN Supersedes 240-60 September 2009 COOPER POWER SERIES NX indoor current-limiting fuses General Eaton provides overload protection for all indoor and underground

More information

MATERIAL SPECIFICATION ELECTRIC OPERATIONS ORGANIZATION. M3902 ****Supercedes BECo Standard E and ComElectric Spec ****

MATERIAL SPECIFICATION ELECTRIC OPERATIONS ORGANIZATION. M3902 ****Supercedes BECo Standard E and ComElectric Spec **** Page 1 of 8 ****Supercedes BECo Standard E2.12-2.12 and ComElectric Spec 6-0895**** 1.0 General Requirements SINGLE PHASE PAD-MOUNTED DISTRIBUTION TRANSFORMERS 1.1 These specifications cover single-phase

More information

SPECIFICATION BULLETIN

SPECIFICATION BULLETIN SPECIFICATIONS Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 150 apply, except as modified under WARRANTY QUALIFICATIONS on page 3. SPECIAL TO THIS PRODUCT:

More information

SWITCHGEAR DIVISION PRODUCT PROFILES

SWITCHGEAR DIVISION PRODUCT PROFILES SWITCHGEAR DIVISION PRODUCT PROFILES Metal-Enclosed Load-Interrupter Switchgear Product Profiles Description: Three-Phase, Group-Operated Load-Interrupter Switches with Fuses in Single and Multi-Bay Assemblies

More information

Disconnect & ByPass Switches

Disconnect & ByPass Switches Disconnect & ByPass Switches Disconnect & Oil Circuit Recloser Bypass Switches; Regulator & Current Transformer Bypass Switches Electrical Apparatus K-SEC 060 & 090 Contents Type D-73 Distribution Class

More information

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application The most advanced Arc-Resistant Switchgear, designed and built to provide maximum safety in the event of an Internal Arcing Fault. 5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application Page 1

More information

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications Descriptive bulletin Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications General overview Reliable, low maintenance and economical Load Interrupter

More information

SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES

SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES SERIES G100 / G110 SPECIFICATION 15KV & 25KV SUBMERSIBLE & VAULT MOUNTED SF 6 -INSULATED VACUUM LOAD INTERRUPTING SWITCHES MANUALLY OPERATED / REMOTELY OPERATED DEAD FRONT SUBMERSIBLE AND VAULT MOUNTED

More information

100 / 110 DRYWELL FUSE SPECIFICATION

100 / 110 DRYWELL FUSE SPECIFICATION 100 / 110 DRYWELL FUSE SPECIFICATION 15KV & 25KV SUBMERSIBLE VACUUM LOAD INTERRUPTERS AND DRYWELL FUSE ASSEMBLIES MANUALLY OPERATED / REMOTELY OPERATED SUBMERSIBLE SWITCHGEAR WITH LOAD INTERRUPTING SWITCHES

More information

C1000 Series Automatic Cap Bank

C1000 Series Automatic Cap Bank C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution

More information

Underground Distribution Switchgear

Underground Distribution Switchgear Underground Distribution Switchgear Functional Specification Guide Functional Specification for 15 kv, 25 kv, or 35 kv Underground Distribution Switchgear 1. Scope 1.1. This specification applies to three-phase,

More information

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv) S&C Power Fuses Types SM- 4, SM-5, SMD-0, and SMD-40 Outdoor Distribution (4.16 kv through kv) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: The seller s standard

More information

S&C Recloser Bypass Disconnects

S&C Recloser Bypass Disconnects S&C Recloser Bypass Disconnects Outdoor Distribution (14.4 kv through 34.5 kv) Application S&C Recloser Bypass Disconnects are station-type devices used to bypass and isolate automatic circuit reclosers

More information

Submersible Vacuum Fault Interrupters

Submersible Vacuum Fault Interrupters Submersible Vacuum Fault Interrupters UG Distribution Medium Voltage Vacuum Fault Interrupters Functional Specification Guide PS024002EN Functional Specification for 2.4kV to 17.5kV UG Distribution Medium

More information

GE 8000-Line Motor Control Centers

GE 8000-Line Motor Control Centers GE 8000-Line -1 ENCLOSURE TYPES TYPE 1 General Purpose, Indoor Intended for use indoors, primarily to prevent accidental contact of personnel with the enclosed equipment, in areas where unusual service

More information

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein. 16425 SWITCHBOARD ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 24 13 An optional keynote to

More information

Cleaning Flooded Gear

Cleaning Flooded Gear S&C Manual PMX Modular Metal-Enclosed Switchgear Outdoor Distribution (13.8 kv and 25 kv) Cleaning Flooded Gear Table of Contents Section Page Section Page Introduction.... 2 Safety Information Understanding

More information

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale S&C Omni-Rupter Switches Outdoor istribution (14.4 kv and 5 kv) Specifications Conditions of Sale STNR: Seller s standard conditions of sale as set forth in Price Sheet apply. SPECIL TO THIS PROUCT: INCLUSIONS:

More information

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE PAGE 261116-1 SECTION 261116 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Design Standard. Purpose: Design Standard:

Design Standard. Purpose: Design Standard: Design Standard Purpose: This design standard has the purpose of creating a consistent application of motor-control centers throughout the East Side Union High School District, therefore achieving a standard

More information

ME Series Fused Sectionalizing Enclosures Style Guide 1VAM SG April 16, 2009 Revision D

ME Series Fused Sectionalizing Enclosures Style Guide 1VAM SG April 16, 2009 Revision D ME eries Fused ectionalizing Enclosures tyle Guide 1VM224701-G pril 16, 2009 Revision D 's dead-front padmount ME series fused sectionalizing enclosures are designed for 200 ampere circuits to protect

More information

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv) Outdoor Distribution (4.4 kv through 46 kv) Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet 50 apply, except as modified under WARRANTY QUALIFICATIONS

More information

Product Specifications for Phase Over Phase GOABS(r)

Product Specifications for Phase Over Phase GOABS(r) 1. General a) This specification covers the design, manufacture, and shipment of phase-over-phase, 1-way, 2-way, 3-way, and 4-way, gang-operated disconnecting switches, both air-break and load-break, for

More information

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5 1.1. APPLICABLE PUBLICATIONS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements, and errata), form a part of this

More information

Figure 1. HX cutout fuseholders.

Figure 1. HX cutout fuseholders. Fusing Equipment Kearney Open Distribution Cutout - Type HX Electrical Apparatus K-SEC 010 GENERAL Application Versatility Cooper Power Systems Kearney HX cutouts can be quickly and economically adapted

More information

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003 Types SM-4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through kv) Conditions of Sale STANDARD: Seller s standard conditions of sale set forth in Price Sheet apply, except as modified under

More information

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34.

Specifications. S&C Power Fuses Types SM and SMLa. For use with SM Refill Units or SMU Fuse Units. Indoor Distribution (4.16 kv through 34. S&C Power Fuses s SM and SMLa Indoor Distribution (4.16 through 34. ) For use with SM Refill Units or SMU Fuse Units Specifications Conditions of Sale STANDARD: Seller s standard conditions of sale set

More information

MATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec ****

MATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec **** Page 1 of 8 ****Supercedes BECo Standard E2.12-2.14 and ComElectric Spec 7-0895**** THREE-PHASE DEADFRONT PAD-MOUNTED DISTRIBUTION TRANSFORMERS, LOOP & RADIAL FEED DESIGNS 1.0 General Requirements 1.1

More information

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv)

S&C Loadbuster Disconnect Switches. Outdoor Distribution (14.4 kv through 34.5 kv) S&C Loadbuster Disconnect Switches Outdoor Distribution ( kv through 34.5 kv) S&C s Loadbuster Disconnect Switches, when used with S&C s Loadbuster tool, provide the ultimate in distribution live-switching

More information

PAD-MOUNTED SWITCHGEAR INSPECTION & MAINTENANCE RECOMMENDATIONS TYPE PSI/II. 15kV 25kV. Qualified Persons

PAD-MOUNTED SWITCHGEAR INSPECTION & MAINTENANCE RECOMMENDATIONS TYPE PSI/II. 15kV 25kV. Qualified Persons Page 1 Qualified Persons... 1 Safety Information... 2 Procedures... 3 Maintenance... 3 Security Inspection (Exterior)... 3 Verify Securing Devices... 3 Maintaining the Exterior... 3 Replacing Labels...

More information

Cleaning Flooded Gear

Cleaning Flooded Gear S&C Manual Metal-Enclosed Switchgear Indoor and Outdoor Distribution (4.16 kv through 34.5 kv) Cleaning Flooded Gear Table of Contents Section Page Section Page Introduction.... 2 Safety Information Understanding

More information

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z PART 1 GENERAL 1.01 1.02 1.03 1.04 1.05 SCOPE The Contractor shall furnish and install fixed power factor correction equipment as specified herein and as shown on the contract drawings. This specification

More information

Installation Instructions LINK---C

Installation Instructions LINK---C IS---LINK---C Page 1 of 10 Installation Instructions LINK---C DEADBREAK CAM LINK OPERABLE CONNECTOR SYSTEM The is a 600 amp, connector designed to: 1.) provide a fully shielded, fully submersible hot stick

More information

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary

Type M3 Hookstick Disconnect Switches Up to 38kV 600 or 900 Amp 40kA Momentary 14B-2 Type M3 Hookstick Disconnect Switches Up to 38kV 0 or 900 Amp 40kA Momentary Application The Chance Type M3 Disconnect Switch is a single-phase hookstick operated switch. It is for manual switching

More information

SECTION PANELBOARDS

SECTION PANELBOARDS SECTION 16470 PANELBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. The general provisions of the contract including General and Special Conditions and General Requirements shall apply to all work under

More information

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

56-SDMS-07 REV. 01 SPECIFICATIONS FOR 56-SDMS-07 REV. 01 SPECIFICATIONS FOR UNIT SUBSTATIONS UP TO 36 kv ALUMINUM TRANSFORMER ALUMINUM BUS BARS LVDP This specification is property of SEC and subject to change or modification without any notice

More information

INDEX Welcome 1.2 Contacting Powergrid Solutions, Inc. 1.3 Terms Of Usage 1.4 Product Codes and Descriptions

INDEX Welcome 1.2 Contacting Powergrid Solutions, Inc. 1.3 Terms Of Usage 1.4 Product Codes and Descriptions INDEX SECTION 1 INTRODUCTION 1.1 Welcome 1.2 Contacting Powergrid Solutions, Inc. 1.3 Terms Of Usage 1.4 Product Codes and Descriptions SECTION 2 PADMOUNTED ENCLOSURES/CABLE SWITCHING/TERMINATING GEAR

More information

Product Specifications for Aluminum Vertical Break Switches

Product Specifications for Aluminum Vertical Break Switches 1. General a) This specification covers the design, manufacture, and shipment of aluminum vertical break switches, both air-break and load-break configurations, for substation and transmission switching

More information

M-Force three-phase switch

M-Force three-phase switch Supersedes K-SEC 926 December 2012 M-Force three-phase switch Description The M-Force switch from Eaton's Cooper Power Systems is a distribution-class, gangoperated, factory unitized three-phase overhead

More information

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV) SUBSTATION VACUUM CIRCUIT BREAKER (38KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products for utilities

More information

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV) For more than four decades, Myers Power Products has led the switchgear market in quality for the electric industry, delivering highly reliable products

More information

S&C Loadbuster Disconnects

S&C Loadbuster Disconnects S&C Loadbuster Disconnects Outdoor Distribution ( kv through 34.5 kv) With these outstanding features... Up to -ampere continuous ratings, 40,000-ampere RMS asymmetrical momentary ratings Designed for

More information

Fixed, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

Fixed, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification Fixed, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification 1. General 1.1 This specification is for a fixed, medium-voltage, padmounted, three-phase power capacitor bank

More information

MEH Series Sectionalizing Enclosures. Single-Phase and Three-Phase

MEH Series Sectionalizing Enclosures. Single-Phase and Three-Phase MEH Series Sectionalizing Enclosures Single-Phase and Three-Phase ABB MEH Sectionalizing Enclosures ABB s MEH Sectionalizing Enclosures provide an economical and safe sectionalizing tap point for underground

More information

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work Section 16435 - SWITCHBOARDS Introduction Part 1 - General Related Work Section 16070 Seismic Anchorage and Restraint Section 16075 Electrical Identification Section 16080 Power Distribution Acceptance

More information

600 A 15 and 25 kv class Cleer grounding elbow

600 A 15 and 25 kv class Cleer grounding elbow Loadbreak/Deadbreak Connectors CA650013EN Supersedes March 2015 COOPER POWER SERIES 600 A 15 and 25 kv class Cleer grounding elbow General Eaton provides a visible ground on its Cooper Power series 600

More information

Automatic, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

Automatic, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification Automatic, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification 1. General 1.1 This specification is for an automatic, medium-voltage, padmounted, three-phase power capacitor

More information

A. The ratings for the integrated pad-mounted gear shall be as designated below:

A. The ratings for the integrated pad-mounted gear shall be as designated below: Section 16310 - PRIMARY SWITCH STATION PART 1 GENERAL 1.01 Description of Work 1.02 Ratings A. The pad-mounted gear shall be in accordance with the one-line diagram, and shall conform to the following

More information

D-73P disconnect and bypass switches

D-73P disconnect and bypass switches Switches atalog Data 008005EN Supersedes pril 2016 OOPER POWER SERIES D-73P disconnect and bypass switches ontents Description Page D-73P disconnect switch....2 D-73P3 bypass switch....5 D-73P-D cutout

More information

Figure 1. HX cutout fuseholders. Positive Interruption

Figure 1. HX cutout fuseholders. Positive Interruption Fusing Equipment Kearney Open Distribution Cutout - Type HX Electrical Apparatus 327-10 general Application Versatility Cooper Power Systems Kearney HX cutouts can be quickly and economically adapted to

More information

Type MOST oil switch

Type MOST oil switch Underground Distribution witchgear CA285002EN Effective October 20 upersedes 285-20 October 2013 COOPER POWER ERIE ype MO oil switch Contents Description Page General...2 Ordering information....2 Features

More information

OPERATION AND MAINTENANCE OF TRAYER 4000 SERIES PADMOUNTED VACUUM FAULT INTERRUPTER

OPERATION AND MAINTENANCE OF TRAYER 4000 SERIES PADMOUNTED VACUUM FAULT INTERRUPTER OPERATION AND MAINTENANCE OF TRAYER 4000 SERIES PADMOUNTED VACUUM FAULT INTERRUPTER 1) INTRODUCTION 2) CAUTIONS 3) RECEIVING A) UNPACKING B) INSPECTION C) HANDLING D) STORAGE 4) INSTALLATION A) PRE-INSTALLATION

More information

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified. SECTION 26 24 13 LOW VOLTAGE SWITCHBOARDS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. The Conditions of the Contract and applicable requirements of Divisions 0 and 1 and Section 26 00 01, Electrical General

More information

M-Force three-phase switch

M-Force three-phase switch Switches and Disconnects CA008004EN Supersedes May 2015 COOPER POWER SERIES M-Force three-phase switch Description Eaton's Cooper Power series M-Force switch is a distribution-class, gang-operated, factory

More information