FUEL SHUT-OFF/ LOCKOFFS
|
|
- Blanche Ray
- 6 years ago
- Views:
Transcription
1 FUEL SHUT-OFF/ LOCKOFFS Model VFF ET98 Model ET98 with Filter Model FL-206 Model FL V Model FL V Model FL Model FL Model FL Model IMPCO TECHNOLOGIES September, 2017
2 MODEL VFF30 VACUUM FUEL LOCK/FILTER MODEL VFF30 VACUUM FUEL LOCK/FILTER DESCRIPTION The Model VFF30 is a combination fuel lockoff and filter, engineered for use with LPG (liquid or vapor) or Natural Gas Vapor. It is available with hydrin, silicone and fluorosilicone diaphragms. A pressure of 0.5 w.c (0.12kPa) is required to open the lockoff. The VFF30 is suitable for engines up to 325 hp (242 kw) at a maximum working pressure of 312 psi (21.51 Bar). The extra large capacity filter element is fully serviceable. SPECIFICATIONS Fuel Type... LPG Liquid/Vapor, Natural Gas Vapor Inlet Pressure (maximum) psi (21.51 Bar) Flow Rate CFM (12.6 L/s) Operating Temperature Range F to +250 F (-40 C to +121 C) Vacuum Activation Minimum Opening w.c. (0.12kPa) Fully Opened w.c. (2.86 kpa) Minimum Operating Opening w.c. (0.50 kpa) Mounting Position... Vertical (as shown above) Certification... UL (AU1502) Inquire for specific ECE approval IMPCO TECHNOLOGIES September, 2017
3 MODEL VFF30 VACUUM FUEL LOCK/FILTER DIMENSIONS MODEL VFF30 VFF30-2 VFF VFF VFF30-2ULC VFF30-3 DIAPHRAGM TYPE HYDRIN Silicone Silicone Silicone Silicone Fluoro-silicone A B C D E F G FRONT OF OVERALL HEIGHT OVERALL WIDTH 109 mm 114 mm (4.28") (4.50") 109 mm 115 mm (4.28") (4.50") 109 mm 114 mm (4.28") (4.50") 109 mm 115 mm (4.28") (4.50") 109 mm 114 mm (4.28") (4.50") 109 mm 115 mm (4.28") (4.50") OVERALL DEPTH 66.7 mm (2.625") 66.7 mm (2.625") 66.7 mm (2.625") 66.7 mm (2.625") 66.7 mm (2.625") 66.7 mm (2.625") FUEL LOCK TO CTR. OF MOUNTING HOLE MOUNTING HOLES CTR. TO CTR. MOUNTING HOLE THREAD BACK OF FUEL LOCK TO CTR. OF FUEL OUTLET 24 mm (.94") 48mm (1.88") 1/4"-20 37mm (1.44") 24 mm (.94") 48mm (1.88") 1/4"-20 37mm (1.44") 24 mm (.94") 48mm (1.88") 1/4"-20 37mm (1.44") 24 mm (.94") 48mm (1.88") 1/4"-20 37mm (1.44") 24 mm (.94") 48mm (1.88") 1/4"-20 37mm (1.44") 24 mm (.94") 48mm (1.88") 1/4"-20 37mm (1.44") H J K L M MODEL BACK OF FUEL LOCK TO CTR. OF VACUUM PORT AIR VALVE VACUUM PORT (NPT) FUEL OUTLET (NPT) FUEL INLET (NPT) PRIIMER VFF30 32mm (1.25") 1/8" 1/4" 1/4" VFF mm (1.25") 1/8" 1/4" 1/4" VFF mm (1.25") 1/8" 1/4" 1/4" ELECTRIC PRIMER VFF mm (1.25") 1/8" w/check Valve 1/4" 1/4" MANUAL PRIMER VFF130-2ULC 32mm (1.25") 1/8" 1/4" 1/4" VFF mm (1.25") 1/8" 1/4" 1/4" IMPCO TECHNOLOGIES September, 2017
4 MODEL VFF30 VACUUM FUEL LOCK/FILTER COMPONENTS ITEM# PART# DESCRIPTION 1* S Screw, 8-32 Taptite (6) 2 C1-37 Diaphragm cover, (std., VFF30 only) NSS Diaphragm Assy (Hydrin) (RK-VFF30) 3* Diaphragm Assy, Silicone NSS (RK-VFF30-2) Diaphragm Assy, Flourosilicone NSS (RK-VFF30-3) 4* NSS Screw, 8-32 Taptite (3) 5 F3-2 Fulcrum 6 NSS Valve operating lever 7 NSS Body ass'y 8 S1-5 Screw, 1/4-20 x 5/8" SEMS (2) 9* S3-116 Seal, Lip Pin 10* NSS Valve, operating pin 11 S2-40 Valve, spring 12* NSS Screen, back-up filter 13* NSS Filter 14* NSS Filter Assy (includes Filter & Screen) 15* NSS Filter cover gasket 16 C1-38 Filter cover 17 NSS Screw, Taptite (10) 18 AF4-66 Fitting, ball check, assy (not shown, VFF only) 19* NSS Seat, VFF30 20* NSS Washer, Seal Retaining NSS = Not Serviced Separately * Repair Kit Components. Note that extra screws (both slotted and torx) are included in the repair kits to replace any that may be damaged. IMPCO TECHNOLOGIES September, 2017
5 VFF30 VACUUM FUEL LOCK/FILTER MODEL VFF30 VACUUM FUEL LOCK/FILTER ACCESSORIES PART# AC1-57 PART# RK-VFF30 RK-VFF30-2 RK-VFF30-3 PRIMER DESCRIPTION Cover, VFF30 w/electric Primer REPAIR KITS DESCRIPTION Repair Kit, Hydrin Repair Kit, Silicone Repair Kit, Fluorosilicone IMPCO TECHNOLOGIES September, 2017
6 ET98 SHUTOFF/LOCKOFF ET98 MODEL ET98 DESCRIPTION The Model ET98 is an electrically operated safety shutoff valve suitable for high pressure up to 315 psi (21.72 Bar) of LPG liquid, LPG Vapor or Natural Gas Vapor. It is a normally closed Straight-Through Lockoff, opened with 12V DC and is available with either a male or female outlet. As of early 2013, the ET98 shut-off valves will have a new solenoid with a female electrical connector. The part number remains unchanged and includes a matching electrical connector with wires. SPECIFICATIONS Fuel Type... LPG Liquid/Vapor, Low Pressure Natural Gas Vapor Inlet Pressure (maximum) psi (21.72 Bar) Flow Rating... 24,000 NL/H ( kpa Air Electrical Requirement Volts DC/15.5 Watts (1.3 Amps) Operating Temperature Range F to +250 F (-40 C to +121 C) Fuel Filtration Required Microns Mounting Position... Vertical Recommended Certification... UL Recognized. Inquire for specific ECE application Weight... ~12 oz. (470 grams) IMPCO TECHNOLOGIES September, 2017
7 ET98 SHUTOFF/LOCKOFF DIMENSIONS P/N ET P/N ET ET98 IMPCO TECHNOLOGIES September, 2017
8 ET98 SHUTOFF/LOCKOFF To service the lockoff or its electrical connection, both wire pigtail connector and the lockoff (without the wire pigtail connector) are available separately. Refer to the table below for part information: ET98 Lockoff ET98 Lockoff Wire Pigtail Description (w/pigtail Connector) (w/o Pigtail Connector) Connector ET ET Female to Male ET ET Female to Female ET ET Female to Female AW ET ET Female to Male ET ET Female to Female All wire pigtails connect to the solenoid coil of the ET98 using connector Tyco part number AW has insulated wire leads approximately 6.3 (159mm) long AW has a Tyco connector AW has a Metri-pack connector (Packard type PA6) IMPCO TECHNOLOGIES September, 2017
9 ET98 SHUTOFF/LOCKOFF IMPCO TECHNOLOGIES September, 2017
10 ET98 SHUTOFF/LOCKOFF WITH FILTER ET98 FILTER MODEL ET98 w/filter (New Version) DESCRIPTION The Model ET98 with filter is an electrically operated safety shutoff valve suitable for high pressure up to 315 psi (21.72 Bar) of LPG liquid, LPG Vapor or Natural Gas Vapor. It is a normally closed Straight-Through Lockoff, opened with 12V DC featuring an integrated filter. The filter model has two female NPT fittings and a mounting kit. As of early 2013, the ET98 shut-off valves will have a new solenoid with a female electrical connector. The part number remains unchanged and includes a matching electrical connector with wires. SPECIFICATIONS Fuel Type... LPG Liquid/Vapor, Low Pressure Natural Gas Vapor Inlet Pressure (maximum) psi (21.72 Bar) Flow Rating GM (24, psi (400 kpa) Air Electrical Requirement Volts DC/15.5 Watts (1.3 Amps) Operating Temperature Range F to +250 F (-40 C to +121 C) Fuel Filtration Provided Microns Mounting Position... Vertical Recommended Certification... UL Recognized. Inquire for specific ECE application IMPCO TECHNOLOGIES September, 2017
11 ET98 SHUTOFF/LOCKOFF WITH FILTER DIMENSIONS P/N ET (new version) PART# RK-ET98 REPAIR KIT DESCRIPTION Repair Kit, ET-98 w/filter NOTE: The RK-ET98 repair kit cannot be used to repair an ET98 not originally equipped with an integrated fuel filter. IMPCO TECHNOLOGIES September, 2017
12 ET98 SHUTOFF/LOCKOFF WITH FILTER To service the lockoff or its electrical connection, both wire pigtail connector and the lockoff (without the wire pigtail connector) are available separately. Refer to the table below for part information: ET98 Lockoff ET98 Lockoff Wire Pigtail Description (w/pigtail Connector) (w/o Pigtail Connector) Connector ET ET Female to Female AW ET ET Female to Female AW ET ET Female to Female AW All wire pigtails connect to the solenoid coil of the ET98 using connector Tyco part number AW has insulated wire leads approximately 6.3 (159mm) long AW has a Tyco connector AW has a Metri-pack connector (Packard type PA6) IMPCO TECHNOLOGIES September, 2017
13 ET98 SHUTOFF/LOCKOFF WITH FILTER FL-206 MODEL DESCRIPTION The FL-206 model is a normally closed 12 VDC electric solenoid shut off valve, suitable for use with gasoline applications. SPECIFICATIONS Fuel Type... Gasoline Inlet Pressure (maximum) psi (2.1 Bar) Flow Rating psi ( kpa) Electrical Requirement VDC, 8W Operating Temperature Range ºF to 158ºF (-40ºC to 70ºC) Fuel Filtration Required Micron Mounting Position... Any Certification... UL (MH19296) IMPCO TECHNOLOGIES September, 2017
14 FL-206 MODEL DIMENSIONS A B C D E F G H I K MODEL CENTER OF SOLENOID TO WIDEST POINT OVERALL HEIGHT VALVE BODY LENGTH SOLENOID DIA. INLET THREAD TYPE INLET THREAD SIZE (NPT) OUTLET THREAD TYPE OUTLET THREAD SIZE (NPT) FL mm (0.91") 71 mm 42 mm (2.80") (2.01") 32 mm (1.26") FEMALE 1/8" FEMALE 1/8" CTR. OF VALVE TO TOP OF SOLENOID WEIGHT 59 mm 266 G (9.4 (2.32") OZ) IMPCO TECHNOLOGIES September, 2017
15 FL-206 MODEL FL V MODEL DESCRIPTION The FL-218 model heavy-duty electric shutoff solenoid valve, equipped with an integral filter for engines up to 200 cubic inches (3.28L). The solenoid is 12 VDC operated and is normally closed. The internal replaceable filter allows for in-line filtration suitable for use with LPG or low pressure side of Natural Gas applications. SPECIFICATIONS Fuel Type... LPG Liquid/Vapor or Low Pressure Natural Gas Inlet Pressure (max. working) psi (17.24 Bar) Operating Temperature Range ºF to +250ºF (-40ºC to 121ºC) Flow Rating gal/h (15.1 L/h), maximum 2.84 psi (19.6 kpa) Electrical Requirement VDC, 12W Fuel Filtration Required Micron Mounting Position... Any Certification... UL (AU1502) IMPCO TECHNOLOGIES September, 2017
16 FL V MODEL DIMENSIONS A B C D E G MODEL INLET THREAD SIZE (NPT) HEX NUT SIZE OVERALL WIDTH OVERALL LENGTH OUTLET THREAD SIZE (NPT) WEIGHT FL V 1/4" (FEMALE) 9/16" 32 mm 91.2mm (1.25") (3.59") 1/4" (MALE) 510 G (18 oz. ) IMPCO TECHNOLOGIES September, 2017
17 FL V MODEL FL V MODEL KIT-FILTER ELEMENT & GASKET ITEM # PART # DESCRIPTION 1 FL-4748 Kit, Element & Gasket IMPCO TECHNOLOGIES September, 2017
18 FL V MODEL FL V MODEL DESCRIPTION The FL V model heavy duty electric shutoff solenoid valve with an integral filter. The solenoid is 12 volt operated, normally closed and is suitable for LPG and low pressure side Natural Gas applications. The internal replaceable filter allows for in-line filtration and can be used in conjunction with any IMPCO fuel management system. SPECIFICATIONS Fuel Type... LPG Liquid/Vapor or Low Pressure Natural Gas Inlet Pressure (maximum) psi (17.24 Bar) Operating Temperature Range ºF to +250ºF (-40ºC to +121ºC) Electrical Requirement VDC Filter Rating Micron (1.6 mil) Mounting Position... Vertical/horizontal Certification... UL (AU1502) IMPCO TECHNOLOGIES September, 2017
19 FL V MODEL DIMENSIONS MODEL FL V A B C D E G INLET OUTLET OVERALL OVERALL NUT THREAD THREAD HEIGHT WIDTH WIDTH TYPE TYPE WEIGHT 116 mm 48 mm 25 mm 1/4" NPT 1/4"(FEMALE) (4.56") (1.88") (1.0") (MALE) 340 g (12 oz) PART # FL-4748 FILTERS DESCRIPTION Kit Elem & Gasket IMPCO TECHNOLOGIES September, 2017
20 FL / FL MODEL FL / FL MODEL DESCRIPTION The FL / FL model is a low pressure normally closed 12 volt DC safety shut-off valve suitable for use with LPG Vapor or Natural Gas Vapor. The valve is available in six different inlet/outlet configurations and provides two points for hard mounting. The coil assembly is hermetically sealed for excellent moisture resistance. As of early 2013, the FL / FL shut-off valves will have a new solenoid with a female electrical connector. The part number will remain unchanged and will include a matching electrical connector with wires. SPECIFICATIONS Fuel Type... LPG Vapor or Low Pressure Natural Gas Inlet Pressure (maximum) w.c. (3.45 kpa) Flow Rate CFH (9, kpa (Air) Electrical Requirement Volts DC (1.3 Amps) Operating Temperature Range F to +221 F (-40 C to 105 C) Mounting Position... Vertical (Coil Up) ±10 Certification... UL Recognized. Inquire for specific ECE application IMPCO TECHNOLOGIES September, 2017
21 FL / FL MODEL DIMENSIONS FL shut-off (Original version shown) PART NUMBERS To better service the new lockoff or its electrical connection, both the wire pigtail connector and the lockoff (without the wire pigtail connector) are available separately. Refer to the table below for part information: Original FL Lockoff* New Lockoff (solenoid w/female connector)** Description Wire Pigtail Connector FL FL Lockoff, 180 Deg Flow, Female In, Female Out FL FL Lockoff, 180 Deg Flow, Female In, Male Out FL FL Lockoff, 90 Deg Flow, Female In, Female Out, Left Exit FL FL Lockoff, 90 Deg Flow Female In, Female Out, Right Exit FL FL Lockoff, 90 Deg Flow, Female In, Female Out, Right Exit FL FL Lockoff, 90 Deg Flow, Female In, Male Out, Right Exit FL FL Lockoff, 180 Deg Flow, Female In, Male Out, No Mtg Hole FL FL Lockoff, 180 Deg Flow, Female In, Female Out, No Mtg Hole *Includes Wire Pigtail **Wire Pigtail not included IMPCO TECHNOLOGIES September, 2017
22 FL / FL MODEL Clock Position Fitting Type Description Top View 3 M8 Mounting Hole Mount 6 ¾ NPT Female Inlet 9 M8 Mounting Hole Mount 12 ¾ NPT Female Outlet Valve Description: Straight-Through (180 ) Passage (female outlet) IMPCO P/N: FL / FL or -008 (w/out mtg hole) Clock Position Fitting Type Description 3 M8 Mounting Hole Mount 6 ¾ NPT Female Inlet 9 M8 Mounting Hole Mount 12 ¾ NPT Male Outlet Valve Description: Straight-Through (180 ) Passage (male outlet) IMPCO P/N: FL / FL or -007 (w/out mtg hole) Clock Position Fitting Type Description 3 M8 Mounting Hole Mount 6 ¾ NPT Female Inlet 9 ¾ NPT Female Outlet 12 M8 Mounting Hole Mount Valve Description: 90 Left Exit (female outlet) Clock Position IMPCO P/N: FL-50046/ FL Fitting Type Description 3 M8 Mounting Hole Mount 6 ¾ NPT Female Inlet 9 ¾ NPT Male Outlet 12 M8 Mounting Hole Mount Valve Description: 90 Left Exit (male outlet) IMPCO P/N: FL / FL IMPCO TECHNOLOGIES September, 2017
23 FL / FL MODEL Clock Position Fitting Type Description Top View 3 ¾ NPT Female Outlet 6 ¾ NPT Female Inlet 9 M8 Mounting Hole Mount 12 M8 Mounting Hole Mount Valve Description: 90 Right Exit (Female outlet) IMPCO P/N: FL / FL Clock Position Fitting Type Description 3 ¾ NPT Male Outlet 6 ¾ NPT Female Inlet 9 M8 Mounting Hole Mount 12 M8 Mounting Hole Mount Valve Description: 90 Right Exit (Male outlet) IMPCO P/N: FL / FL The wire pigtail connector (AW ) has insulated wire leads approximately 6.3 (159mm) long. The connector is Tyco part number IMPCO TECHNOLOGIES September, 2017
24 FL MODEL FL MODEL DESCRIPTION The FL model lockoff is a normally closed 12 VDC electric solenoid shut off valve, suitable for use in low pressure, dry gas fuel applications. The FL is light weight and can be easily mounted directly to a low pressure regulator or remotely mounted utilizing the single mounting boss. The FL is designed for applications requiring 90º flow direction. SPECIFICATIONS Fuel Type...Low Pressure LPG Vapor or Natural Gas Vapor Inlet Pressure (maximum)...(13.8 w.c.) 3.4 kpa Flow Rate...N/A Electrical Requirement...12 VDC, (0.14A) Operating Temperature Range F to +250 F (-40 C to +121 C) Mounting Position...Vertical (Coil Up) Certification...UL Approved (YIOZ2.MH26404) IMPCO TECHNOLOGIES September, 2017
25 FL MODEL DIMENSIONS MODEL FL A B C D E F G H I K FLOW DIRECTION OVERALL HEIGHT VALVE BODY LENGTH SOLENOID DIA mm 65.1 mm 44.4 mm (2.845") (2.565") (1.75") INLET INLET THREAD THREAD SIZE TYPE (RC) OUTLET OUTLET THREAD THREAD SIZE TYPE (RC) CTR. TO VALVE TO TOP OF SOLENOID WEIGHT 59.6mm kg FEMALE 1/2" FEMALE 1/2" (2.3") (18.4 OZ) IMPCO TECHNOLOGIES September, 2017
26 FL MODEL FL MODEL LOCKOFF DESCRIPTION The Model FL is a large capacity, low pressure, 12 VDC normally closed, electric shut off. SPECIFICATIONS Fuel Type... LPG Vapor or Low pressure Natural Gas Inlet Pressure (maximum) psi (10kPa) Capacity... N/A Electrical Requirement VDC, 1200ma Operating Temperature Range... 32ºF to +122ºF (-0ºC to +50ºC) Fuel Filtration Required Micron Mounting Position... Vertical (Coil Up) Recommended Certification... UL 429, MH9011 IMPCO TECHNOLOGIES September, 2017
27 FL MODEL DIMENSIONS A B C D E F MODEL HEIGHT DEPTH OVERALL WIDTH SIDE TO CTR OF OUTLET INLET/ OUTLET (NPT) CONNECTOR HEIGHT FL mm 96.0mm 82.0mm 31.0mm (3.89") (3.78") (3.23") (1.22") 3/4" 55mm (2.17") IMPCO TECHNOLOGIES September, 2017
MODEL E & PE REGULATORS
The model E & PE are engine heated two-stage regulator/vaporizers. The model E provides a choice of two negative outlet pressures. A blue secondary spring to provide a -1.5 w.c. (0.37 kpa) output and an
More informationREGULATORS REGULATORS
Model AHR50-D... 146 11A17... 148 Model T52... 151 Model KN... 153 Model 202A... 157 Model T60... 159 Model J... 163 Model PJ... 167 Cobra... 171 P-Cobra... 175 Model C250A... 179 Model 120A... 183 Model
More informationMODEL CA125 CARBURETOR
MODEL CA125 CARBURETOR The Model 125 carburetor is a single-diaphragm air valve carburetor/mixer for applications requiring air flow up to 235 CFM (111 L/s). It offers a down draft air inlet that can be
More informationMODEL CA100 CARBURETOR
MODEL CA100 CARBURETOR The Model 100 is a single diaphragm air-gas valve carburetor/mixer. It offers a 90 degree air inlet to provide low overhead clearance, and is available with several Air Horn and
More informationDIMENSIONS MIXER THRTL. SAE HORN OVRAL. BODY OVRAL. BODY FLANGE OF AIR CARB WIDTH DIA. 159 mm (6.250") N/A. 148 mm (1.688") 159 mm (6.
DIMENSIONS A B C D E F G H I MIXER FLANG. CTR. TO AIR TO CTR. SAE CTR. BOLT HORN OVRAL. NPT OVRAL. BODY SHAFT OF AIR CARB BODY FLANGE SPACING BORE DIA. WIDTH INLET HEIGHT HEIGHT DIA. HORN 225-94 AT2-6
More informationFuel Systems & Components for LPG and Natural Gas Engines
Fuel Systems for LPG and Natural Gas Engines STREAMLINE INTERNATIONAL SALES OFFICES Toll-free: (800) 451-7040 E-mail: fsp@woodward.com USA / NILES Tel: +1 (847) 967-7730 E-mail: fsp@woodward.com BRAZIL
More informationFuel Systems for LPG and Natural Gas Engines
Fuel Systems for LPG and Natural Gas Engines Fuelock Filters Regulators & Vaporizers Mixers & Carburetors Product Catalog Woodward s Streamline fuel system products are easy to select and easy to use.
More informationFuel Systems & Components for LPG and Natural Gas Engines
NGVI North America Fuel Lock Filters Fuel Systems & Components for LPG and Natural Gas Engines Regulators & Vaporizers Fuel Systems for LPG and Natural Gas Engines Product Catalog North America Mixers
More informationIntroduction. Marine Turbine Series. Model Illustrations. Special Notes. Specifications 77/1000MA 73/1000MA 75/500MAX 75/900MAX 79/1000MAV 75/1000MAX
Introduction Model Illustrations 5MA 5MAM 9MA 1MA 7/1MA 77/1MA 75/5MAX Special Notes 75/9MAX 75/1MAX 79/1MAV 1. See--thru bowl MA / MAX / MAV units are approved for Diesel service only. UL Listed, USCG
More informationMODEL C-COBRA SERIES CONVERTER REPAIR KIT INSTRUCTIONS
MODEL C-COBRA SERIES CONVERTER REPAIR KIT INSTRUCTIONS Important: Any maintenance, service or repair should be performed by trained and experienced service technicians. Proper tools and equipment should
More informationLarge Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions
Engineering & Manufacturing Solutions LEFC Specifications: See flow chart for capacity. Max. 3000 psi cartridge input pressure. Nominally Rated for 3000 psi (207 bar). Tank Port - #4 SAE (10 psi (0.69
More informationQUICK REFERENCE GUIDE GUÍA DE REFERENCIA GUIDE DE RÉFÉRENCE FACILE
QUICK REFERENCE GUIDE GUÍA DE REFERENCIA GUIDE DE RÉFÉRENCE FACILE AISAN SY51466 Overhaul Kit, Fuel Warning, 6FG10-30, 7FG10-45 with 4Y and 5K SY59387 Regulator, 3-Way Catalytic, 7FGCU15-70, 7FGU15-80
More informationFailure to follow these codes, regulations and recommendations could result in hazardous installation, bodily injury and/or death.
Carburetors IMPORTANT INFORMATION: Product must be installed and used in strict conformance with NFPA Pamphlet 8 and/or NFPA Pamphlet 4 and all other codes, regulations and manufacturer recommendations.
More informationEFC. Electronically Adjustable Proportional Pressure Compensated Flow Control
Engineering & Manufacturing Solutions Specifications: See flow chart for capacity. 3000 psi (207 bar) rating. Weighs 8-1/2 lbs. (3.9 kg). Standard Port size #12SAE (1-1/16 12). 10-Micron Filtration Recommended.
More informationSTC Manual & Actuated Process Valves
STC Manual & Actuated Process Valves Fine Quality Precision Engineered Excellent Prices Advanced Design connects fluid power to industrial automation Table of Contents STC Valve Numbering System.......2
More informationSST Series Sand Media Filtration Systems
SST Series Sand Media Filtration Systems Kits and Spare Parts Listing LS-695 (Rev. 6 / 07) Page 1 SST SAND FILTERS Installation Profile Automatic Systems WLS-594B(REV.11/03) Installation Configurations
More informationEI, EIO INTRINSICALLY SAFE VALVES
EI, EIO INTRINSICALLY SAFE VALVES Definitions C a : Maximum Allowed Capacitance I sc : Maximum Output Current V oc : Maximum Output Voltage C i : Maximum Internal Capacitance L a : Maximum Allowed Inductance
More informationG96 Series BASOTROL Dual Operator Valve
Product Bulletin Issue Date March 5, 2013 G96 Series BASOTROL Dual Operator Valve The G96 Series BASOTROL valves are combination, dual operator, automatic valves available with or without a pressure regulator.
More informationSentronic PLUS 614 Series
Sentronic PLUS 64 Series Proportional Technology www.asco.com PRESSURE CONTROL: 64 SERIES SENTRONIC PLUS Sentronic PLUS Sentronic PLUS is a digitally operated pressure regulator valve. This valve accurately
More informationReliable Overspeed Protection with the G4 Diesel Fuel Stop Solenoid
Reliable Overspeed with the Diesel Patented 2/4 Way valve Patent No. 97 830 22 06 Energise to run Connection Energise to stop Connection 1. This 2/4 Way Solenoid Valve will very reliably stop a diesel
More informationLPG QUICK REFERENCE GUIDE GUÍA DE REFERENCIA GUIDE DE RÉFÉRENCE FACILE
LPG QUICK REFERENCE GUIDE GUÍA DE REFERENCIA GUIDE DE RÉFÉRENCE FACILE AISAN TSA/SY1237617 Description Application Notes Years Diaphragm TSA/SY1237619 Diaphragm TSA/SY35236 Filter kit 6FGCU15-18, 7FGCU15-70,
More informationM/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners
M/MR Modulating Valves design certified For Atmospheric, Infrared, and Direct Fired urners TALE OF CONTENTS Description/Specifications... 1 Introduction... 2 Direct Fired Applications (Negative Pressure)...
More informationVFDAVV 1/2 VFDAVV VACUUM VALVES. DIMENSIONS (mm)
VACUUM VALVES VFDAVV VACUUM VALVES Direct acting vacuum valves 12VDC, 24VDC, 110VAC & 230VAC 1/4 & 1/2 Ports Full size high flow orifice 3-way Operation 2-way Operation (plug exhaust port using VFBP-U02)
More informationEVP SERIES PROPORTIONAL CONTROL VALVES
EVP SERIES PROPORTIONAL CONTROL VALVES 207 Clippard is pleased to add the EVP series proportional control valve to our electronic product line. This product combines the features of the existing EV series
More informationGeneral The Racor Marine Diesel Spin--on Series feature a variety of compact sizes to fit most installations and cramped engine compartments.
Selection Selection Information General The Racor Marine Diesel Spin--on Series feature a variety of compact sizes to fit most installations and cramped engine compartments. Mounting Heads: These units
More informationPACKED SPOOL 4-WAY DIRECTIONAL CONTROL VALVE.
PACKED SPOOL 4-WAY DIRECTIONAL CONTROL VALVE www.elwood.com 0 0 1 : 0 0 0 C E R T I F I E D C O M P A N Y 4-Way 3-Postion Valve 4-WAY, 3-POSITION DIRECTIONAL VALVE, AIR SOLENOID OPERATED SHOWN; DIRECT
More informationG4 Diesel Fuel Shut off Valve A very safe method to protect YOUR engine
G4 Diesel Fuel Shut off Valve A very safe method to protect YOUR engine With the G4 2-position /4 way fuel valve When an alarm signal occurs, the G4 fuel valve instantly reverses the supply pump suction
More informationT60 REGULATOR REPAIR KIT INSTRUCTIONS
T60 REGULATOR REPAIR KIT INSTRUCTIONS This PPI covers the repair of Series I and II T60 regulators using either a minor or major repair kit. Important: Any maintenance, service or repair should be performed
More information4 WAY DIRECTIONAL CONTROL VALVE AO
B Certificate 4 WAY DIRECTIONAL CONTROL VALVE AO ISO 91:2 WITH DESIGN #2.2.1 AO12O4LS B A P T AO12T4JRD FEATURES: SMALL AND COMPACT to fit your design requirements. POSITIVE METERING in either direction
More information2-Way/2 Position Valves
4 2-Way/2 Position Valves Two-way solenoid valves have one inlet and one outlet, and are used to permit and shut off fluid flow. Two Types of Operations Apply Normally Closed (NC) Fluid is shut off when
More informationFT150 MIXER REPAIR KIT INSTRUCTIONS
FT150 MIXER REPAIR KIT INSTRUCTIONS This PPI addresses the procedure to service the FT150 Fuel Mixer used on the certified Spectrum III 4.3 liter GM engines in the event the fuel mixer becomes contaminated.
More informationPRO-II SERIES SAND MEDIA FILTRATION SYSTEMS Kits and Parts Listing
PRO-II SERIES SAND MEDIA FILTRATION SYSTEMS Kits and Parts Listing TABLE OF CONTENTS Assembling Components...page 8" Tanks & Tank Kits... " & " Dia. Tank & Tank Kits... Manifold Kits 6", 8" & 0"... 5-5
More informationHeavy Duty Hydrostatic Transmissions
Heavy Duty Hydrostatic Transmissions Features and Benefits Typical Applications Construction Transit Mixer Road Roller Paver Motor Grader Loader Dozer Material Handling & Utility Crane Sweeper Lift Truck
More informationWEIGHT (lb) PART NO WITH ACCESS CONNECTION (ODS) BALL PORT DIAMETER WA WAS
SUPERIOR - BALL VALVES WA SERIES (WELDED) WAS Series (Welded with Access Fittings) Full Service Temperature Range of -40 F to +325 F. Forged Brass Body and Seal Cap. Design Working Pressure: 700 psig.
More information400 Series Spin-on Fuel Filter/Water Separators
00 Series Spin-on Fuel Filter/Water Separators Instruction Part Number 09 Rev G 00 Series fuel filter/water separators are designed to handle today s tough fuel filtration problems and can be used anywhere
More informationS P R AY E R VA L V E S AND C O N T ROL S C AT A L OG
Q UA L I T Y VA LV E S A N D C O N T R O L S. TO D AY A N D TO M O R R O W. Texas Industrial Remcor, Inc. CATALOG NO. 33 The new RC2 control system: Ensures no potential leaks in the tractor cab when using
More informationMB SERIES SMB SERIES MINIATURE TANK BREATHERS MINIATURE TANK BREATHERS ACCCESSORIES. Phone (608) Fax (608)
G1 MB SERIES MINIATURE TANK BREATHERS 10 Micron Filtration (Nominal) Shatter Resistant Plastic Construction Temperatures Up to +225 F Model A B Number Thread Size Overall Height MB-02-10 1/4 NPT 1.8 MB-03-10
More informationMarine Fuel Filtration Marine 800 Series
Racor recyclers offer large diesel engine operators both ease of maintenance and continuous engine operation. Continuous operations include filter changeouts and the draining of accumulated water from
More informationSeries 1 Model Codes
Eaton Heavy Duty Hydrostatic Transmissions No. 11-06-0866su EN 1000 (Supplement Sheet TO 11-866) Series 1 Model s Models 33 through 76 Hydrostatic Transmissions Series 1 Variable Pump Model The following
More informationAccessories and spare parts
Accessories and spare parts ACCESSORIES AND SPARE PARTS FOR SOLENOID VALVES G9150/R06 9150/R07 9150/R08 9150/R09 9150/R10 9151/R04 9150/R50 9150/R11 9150/R43 008217 008218 008229 200193 009060 200646 004259
More informationG190 LT-145 (1992) Page 1 of 27 42" Mower Deck
132-736G190 LT-145 (1992) Page 1 of 27 42" Mower Deck 132-736G190 LT-145 (1992) Page 2 of 27 42" Mower Deck 3 17600A 1 S 42" Deck Ass'y. Code: N notates a new part (not previously existing). 813-06119
More informationPRESSURE TRANSDUCERS. Specifications. Individual Specifications
GEMS COMPLIANT 00 Series and 00 Heavy Duty Series Compact OEM Pressure Transmitters 0 00 psi to 0-0,000 psi ranges (0- bar to 0-,00 bar) High Proof Pressures Broad Choice of Outputs RoHS Compliant For
More informationSTC. Manual & Actuated Process Valves. Fine Quality. Precision Engineered. Advanced Design. Excellent Prices. Solenoid & Process Valves
Catalog: PUB 07A PV STC Manual & Actuated Process Valves Advanced Design Precision Engineered Fine Quality Excellent Prices D1 connects fluid power to industrial automation Table of Contents STC Process
More informationSSI Technologies Application Note PS-AN3 MediaGauge Digital Pressure Gauges Product Overview
Product Description The MediaGauge digital pressure gauges have better accuracy, longer life and standard multiple functions which make it a better choice than mechanical pressure gauges. The MediaGauge
More informationBRASS BALL VALVES. CSA, UL, cul CGA 9.1 and FM Approved. Female NPT, Male NPT and Flare ends in various configurations from 3/8 to 1.0.
195 Series Ball Valves BRASS BALL VALVES CSA, UL, cul CGA 9.1 and FM Approved. Female NPT, Male NPT and Flare ends in various configurations from 3/8 to 1.0. Hot forged brass body Blow-out nickel plated
More informationAtomizer 36-DC User Guide
TECHNICAL INSTRUCTIONS Atomizer 36-DC User Guide SERVICE CASE HUMIDIFICATION Specification Sheet... 2 Installation Guide... 3 Layout Diagram... 4 Maintenance Guide... 5 Wiring Diagram... 6 Pull Sheet...
More informationASSY, CRANKCASE WITH SLEEVE
1 0G7908A 1 ASSY, CRANKCASE WITH SLEEVE 2 0E9843A 1 SEAL, 38 I.D. CRANKSHAFT GREEN 3 0G0919 5 SCREW, HHFCS M6-1.0 X 12 G8.8 4 0G9100 1 ASSEMBLY, BREATHER DUAL BREATHER 5 0C3005 1 GASKET, BREATHER COVER
More informationB21 Series BASOTROL Gas Valve
Installation Instructions B21 Issue Date September 19, 2017 Installation IMPORTANT: These instructions are intended as a guide for qualified personnel installing or servicing BASO Gas Products. Carefully
More informationBGD278 Series BASOTROL CE Approved Gas Valve
Product Bulletin Issue Date November 16, 2012 BGD278 Series BASOTROL CE Approved Gas Valve The BGD278 Series gas valve is a combination main and pilot valve intended for use in conjunction with solid-state
More informationElectronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33
Electronic Proportional (EP) Control for Heavy Duty Series 2 Piston Pumps Model 33 Model 39 Model 46 Model 54 Model 64 EP Control for Heavy Duty Series 2 Piston Pumps Table of Contents Introduction........................................................................
More informationQT025A 2.4L 25 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency
STANDBY POWER RATING 25 kw, 31 kva, 60 z Image used for illustration purposes only Features Generator Set Benefits PROTOTYPE & TORSIONALLY TESTED PROVIDES A PROVEN UNIT UL2200 TESTED ENSURES A QUALITY
More informationModel Model Model
Filter Separators Model 9003 Model 9004 Model 9001 & 9032 Model 9002 EXAIR's Filter Separators remove water, dirt and rust from your compressed air system. They prevent these contaminants from plugging
More informationInstallation Manual FTI-10A & FTI-20A SINGLE TANK. Automated Fuel Maintenance System FUEL TECHNOLOGIES INTERNATIONAL
Installation Manual Automated Fuel Maintenance System FTI-10A & FTI-20A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL 05/01/2016 Rev A Fuel Technologies FTI-10A & FTI-20A Single Tank Installation Manual
More informationC 0 Valve, Exhaust (1/32" oversize) C 0 Valve, Exhaust (Standard) (Conventional
H30-35359P Page 1 of 8 Engine Parts List #1 H30-35359P Page 2 of 8 Engine Parts List #1 1 34708A 0 Cylinder Assy. (2-1/2" Bore) 2 26727 0 Pin, Dowel 3 27642 0 Plug, Drain 4 32600 0 Seal, Oil 5 29314B 0
More informationMODIFICATIONS AVAILABLE - MADE TO ORDER - CONSULT OUR FACTORY. (MINIMUM ORDER MAY BE REQUIRED.)
NEEDLE VALVES - ANGLE & CROSS PATTERN Flow can be accurately controlled from full orifice opening to shut off. Fluid flow is readily visible through large sight window. Cross pattern can be used singularly
More informationPRESSURE TRANSDUCERS. Specifications. Individual Specifications
00 Series and 00 Heavy Duty Series Compact OEM Pressure Transmitters 0 50 psi to 0-0,000 psi ranges (0-.5 bar to 0-,00 bar) High Proof Pressures Broad Choice of Outputs RoHS Compliant For OEMs that need
More informationControl Valve Specifications
Control Valve Specifications Available in two-way, three-way and four-way configuration and with port sizes from 10-32UNF through to 1/2"NPT. The N2V & N3V1 offering is a direct acting solenoid poppet
More informationTrueDRY DR65/DR90/DR120
TrueDRY DR65/DR90/DR120 Ventilating Dehumidification System DR65 Specifications Part Number: DR65A2000 Blower: Supply Voltage: Amps: 160 CFM @ 0.0 in. WG 100 CFM @ 0.6 in. WG 120 VAC; 60 Hz. 5.2 A Power
More informationMX-1408 SELF-CONTAINED EXTRACTOR REPLACEMENT PARTS LIST
MX-1408 SELF-CONTAINED EXTRACTOR REPLACEMENT PARTS LIST SECTION 100 - TANK ASSEMBLY Ref Part Description Part 2 Dome w/filter (#2 & 8) 402478 3 Complete Solution Tank Cover 423130 5 Dome w/filter & Gasket
More informationM O D E L S EST- FL PARTS MANUAL Rev 1.00A
M O D E L S EST- FL PARTS MANUAL Rev 1.00A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com TABLE
More informationMODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.04A
MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.04A CMA DISHMACHINES 12700 KNOTT STREET GARDEN GROVE, CALIFORNIA 92841 800-854- 6417 FAX 714-895-2141 www.cmadishmachines.com TABLE OF CONTENTS PARTS
More informationAP/UP, AP/MIL Series Magnetic Circuit Protectors
AP/UP, AP/MIL AP/UP, AP/MIL Series Magnetic Circuit Protectors Introduction 68 Single Pole 69 Multi-Pole 70 Configurations 72 Operating Characteristics 73 Delay Curves 74 Specifications 75 Decision Tables
More informationINSTRUCTION MANUAL ADDEN600V R1 AQUAVAR CPC. (Centrifugal Pump Control) 600 VOLT ADDENDUM
INSTRUCTION MANUAL ADDEN600V R1 AQUAVAR CPC (Centrifugal Pump Control) 600 VOLT ADDENDUM Cable Sizing/Ratings 500 600 Volt Drives The following table provides Aquavar CPC rating information and recommended
More information0 900 psi Pressure-Reducing Diaphragm Regulator
Instruction Sheet P/N 009506-09 0 900 psi Pressure-Reducing Diaphragm Regulator Description The Nordson 0 900 psi diaphragm regulator reduces high primary pressures to lower secondary pressures. It is
More informationSingle Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.
Single Pole Circuit Protectors 55 Multi-Pole Circuit Protectors 56 Configurations 58 Operating Characteristics 59 Delay Curves 60 Specifications 61 Decision Tables 62 SINGLE POLE CIRCUIT PROTECTORS The
More informationMiniature Multimedia Valves
2 Inert Isolation PTFE 3-Way Solenoid Valve Series 1 The Series 1 diaphragm type valve has a low internal volume and rapid response time, which enables users to get readings quickly for their analysis.
More informationIMPORTANT INFORMATION
Table of Contents IMPORTANT INFORMATION Section 1A - Specifications SPECIFICATIONS 1 A Master Specifications.................... 1A-2 Torque Chart......................... 1A-6 Standard Hardware...................
More informationMarine Fuel Filtration. Marine FBO. Features:
The Racor assembly is specifically designed to meet the filtration requirements of today s high pressure common rail diesel injection systems. The unit is used for fuel dispensing pumps or as a primary
More informationBGD258 Series BASOTROL CE Approved Class A Gas Valve
Product Bulletin Issue Date May 21, 2010 BGD258 Series BASOTROL CE Approved Class A Gas Valve The BGD258 Series multi-function gas control valve works in conjunction with an electronic sequence control
More informationFor Discount Tecumseh Engine Parts Call or V J Page 1 of 8 Engine Parts List #1
V60-70346J Page 1 of 8 Engine Parts List #1 V60-70346J Page 2 of 8 Engine Parts List #1 1 34177 0 Cylinder Assy. (2-5/8" Bore) 2 27652 0 Pin, Dowel 3 31461 0 Bushing, Crankshaft 4 27876B 0 Seal, Oil 5
More informationVALVES. FIMCO Code # MFG Part # std $ fp $ fp $
97 VALVES std = standard port fp = full port POLY BOLTED STAINLESS STEEL BOLTS, NUTS & WASHERS Size 5143361 60540 1/2 fp $ 29.29 5143362 60541 3/4 fp $ 29.29 5143363 60542 1 std $ 29.29 5143364 60543 1
More informationSolid state ignition Beckett CleanCut fuel pump with oil valve Air tube 2-3/4" UL recognized. Beckett Burner Chart
Your One Stop Shop for Parts 115 / 230 Volt Oil Burners.4 to 3 GPH firing rate 6-1/4" Blower fan 115V and 230V 3450 RPM Pump/blower motor Solid state ignition CleanCut fuel pump with oil valve Air tube
More informationFITTINGS CHEST FITTINGS CHEST. Get organized with the Pneuforce Fittings Chest!
FITTINGS CHEST FITTINGS CHEST Get organized with the Pneuforce Fittings Chest! Over 40 Different Compartments Easy Carry Handle Holds and Includes 420 Fittings All threaded Models Have the Unique Pneuforce
More informationFor Discount Tecumseh Engine Parts Call or V H Page 1 of 8 Engine Parts List #1
V60-70291H Page 1 of 8 Engine Parts List #1 V60-70291H Page 2 of 8 Engine Parts List #1 1 33361A 0 Cylinder Assy. (2-5/8" Bore) 2 27652 0 Pin, Dowel 3 31461 0 Bushing, Crankshaft 4 27876B 0 Seal, Oil 5
More informationInstallation Manual. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL
Installation Manual Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL Replacement Manuals Available on Website: www.fueltechnologiesinternational.com 07/15/2015 Rev E Fuel Technologies
More informationG196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve
Product Bulletin Issue Date March 13, 2013 G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve The G196 Series valves use the reliable valve body and magnetic operators from
More informationSRG LPG Liquid Service/Offtake Valve Type /
SRG LPG Liquid Service/Offtake Valve Type 480-426 / 480-427 Inlet Connection Outlet Connection Width across flats ¾ NPT 1 ¼ NPT M26x1,814 36 mm 46 mm Product Description: The SRG type 480 liquid service
More informationElectronic Proportional (EP) Control for Medium Duty Piston Pumps
Electronic Proportional (EP) Control for Medium Duty 72400 Piston Pumps EP Control for Medium Duty 72400 Piston Pumps Table of Contents Introduction........................................................................
More informationVacuum Filters. Catalogue Edition 2
Vacuum Filters Catalogue Edition 2 INLINE VACUUM FILTERS Vacuforce plastic in-line filters provide easy monitoring, economy and safety. These shatterproof filters are 100% airtight, can withstand high
More informationMAX FLUID TEMPERATURE
Operation is similar to standard centrifugal pumps, except the impeller is driven with a magnetic coupling, eliminating the need for a shaft seal. Magnetic drive pumps must be used where flooded suction
More informationVacuum Gauge Catalog
2019 Vacuum Gauge Catalog Possibly The World s Best Gauge Tubes! 1/8 in. NPT Standard Internal Volume Only 0.78 cc Working Pressure to 300 PSI (Tested to 1200 PSI) NO PLASTIC! Pirani Gauges 1 to 2000 mtorr.01
More informationStandard Coils and Proportional Valve Coils
COILS AND ELECTRONIC CONTROLS Standard Coils and Proportional Valve Coils WHY HYDRAFORCE STANDARD COILS OUTPERFORM COMPETITIVE UNITS High Quality Materials HydraForce coils are made with high quality,
More informationM O D E L S E S T / E S T T A L L PARTS MANUAL Rev 1.08 C M A D I S H M A C H I N E S K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841
M O D E L S E S T / E S T T A L L PARTS MANUAL Rev 1.08 C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 54-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com
More informationVALVES POLYPROPYLENE STYBBY BALL VALVES POLYPROPYLENE 3-WAY BALL VALES. Fax Toll-Free
EPDM- seals Full-Port EPDM- seals Full-Port Viton seals Full-Port POLYPROPYLENE SINGLE UNION BALL VALVES PARTS NO. FPT SIZE MAX. PSI MP-S301200PP 1/2" 240 MP-S301250PP 3/4" 240 MP-S301320PP 1" 240 MP-S301400PP
More informationVAS VAS VACUUM SWITCH SPECIFICATIONS. DIMENSIONS (mm)
VACUUM SWITCHES VAS VACUUM SWITCH Diaphragm vacuum switch Compact size Lightweight Inch port sizes 5/32, 1/4 & 5/16 Metric port sizes 4, 6 & 8mm Fully adjustable VAS 10 06 Series Body Size 10 Vacuum Port
More informationWARNING. Diode Package The Murphy diode package ( ) is designed to allow the fuel shutoff valve to be used with dual Magneto Ignition systems.
M2582, M508, and M580 Series Electromechanical and Pneumatic, Fuel Gas Shutoff Valves Installation and Operation Instructions Please read the following instructions before installing. A visual inspection
More informationGROUP E EXPLODED VIEW: EV FUEL SYSTEM 2.4L G2 DRAWING #: 0G1151 ITEM PART# QTY. DESCRIPTION
EXPLODED VIEW: EV FUEL SYSTEM 2.4L G2 DRAWING #: 0G1151 GROUP E ITEM PART# QTY. DESCRIPTION 1 026915 2 NIPPLE CLOSE 3/4 X 1.375 2 075580 1 FLANGE FUEL INLET 3 0F6390C 1 REGULATOR ASSY 2.4L (25KW) 0F6390B
More informationMODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.04B
MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.04B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com
More informationGLOBAL PRODUCTS CATALOG
GLOBAL PRODUCTS CATALOG IMPCO Technologies, Inc. 16804 Gridley Place Cerritos, California 90703-1741 Phone: (562) 860-6666 Fax: (562) 860-3088 www.impco.ws 2001 IMPCO Technologies, Inc. All Rights Reserved
More informationMODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.05A
MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.05A C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com
More informationAIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT
FORM NO. H11-516 REV. 1 Supersedes Form No. H11-516 Rev. 0 AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT Features Versatile 4-way convertible design for upflow, downflow, horizontal
More informationMODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.03B
MODELS EAH / EC/E TALL/3-Door Parts Manual Revision 1.03B C M A D I S H M A C H I N E S 1 2 7 0 0 K N O T T S T R E E T GARDEN GROVE, CALIFORNIA 92841 800-8 5 4-6 4 1 7 FAX 714-895-2141 www.cmadishmachines.com
More information2 Fluid Level Management
2 Fluid Level Management Introduction.................................... 2-3 REN Oil Level Regulator........................ 2-5 REN Slow Flow Meter.......................... 2-9 Slow Flow Meter Remote
More informationREAD THIS FIRST. For questions or help with this product contact Tech Support at (570) or
The following changes were made to this machine since the owner's manual was printed: Obtained CSA certification meeting CSA C22.2 #105-1953 and UL 987-7th standards. Changed transformer, contactors, overload
More informationCA55 Standard Carburetor/Mixer
CA55 Standard Carburetor/Mixer Important: Any maintenance, service or repair should be performed by trained and experienced service technicians. Proper tools and equipment should be used to prevent injury
More information2 4 8 9 0 2 4 8 R4248 Starter ( Volt) New - Not Rebuilt 84M9 (TO20, TO0, TO >SN 20) 2 R04 Starter ( Volt) 2 Bolt Mount, Type V9 8298M9 (TEA20, 80, 8mm Gas >SN 20000) 29 R4 Starter Drive Fits R04 Starter
More informationSpecial Applications Require Special Tools
Index Routers.................. 102-103 Tappers..................... 104 Clinch Nut Tools.............. 106 Rivet Shavers................ 107 Skin Clamp Runners........... 108 Saws................... 109-110
More informationSPARE PARTS PRICE LIST SEAKEEPER SERIES
SPARE PARTS PRICE LIST SEAKEEPER SERIES UPDATED 3.6.2018 COMMON PARTS SECTION PAGE NUMBER ELECTRONIC SUB-ASSEMBLY 6 SEAKEEPER 3 SECTION PAGE NUMBER ELECTRONIC SUB-ASSEMBLY 7 BRAKE SUB-SYSTEM 7 COOLING
More informationRAZOR. RAZOR HVLP Spray Guns
RAZOR RAZOR HVLP Spray Guns Provides generous material flow that helps you get the job done quickly Offers exceptional atomization rate Promotes a superior finish Proven effective for clear coat, base
More informationSERVICE PARTS MANUAL
SERVICE PARTS MANUAL 28V SERIES SNOW PLOWS FOR PLOW SERIAL NUMBERS AFTER 28VG100000 28VD100000 07 Sno-Way International 9710097F TABLE OF CONTENTS Page PARTS LIST INTRODUCTION... 2 POWER PACK FRAME...
More information