NUFORS-DC VALVE SERVICE

Size: px
Start display at page:

Download "NUFORS-DC VALVE SERVICE"

Transcription

1 Maintenance Instructions NUFORS-DC VALVE SERVICE Direct Cylinder operated level sensed condensate drain 08/14 GENERAL OPERATION The NUFORS-DC removes condensate from compressed air systems without using electricity. The discharge process is automatic and is based on a 2/2 way level controlled valve principle that operates a direct cylinder valve. The NUFORS-DC is ideally suited in applications where power is not available, too expensive or not reliable. The integrated stainless steel strainer protects the valve, optimising the discharge performance. The condensate level can be viewed through the sight port which offers a visual monitoring of the condensate level. 1

2 SAFETY INSTRUCTIONS SAFETY AND PROPER USAGE To ensure safe and enduring performance of this product, you must comply strictly with the instructions enclosed herein. Non-compliance with instructions or improper handling of the product will void your warranty! This product is designed to drain condensate from compressed air systems. Usage of this product in conditions not specified in this manual or in contrary to the instructions hereby provided is considered IMPROPER. The manufacturer will not be held liable for any damages resulting from improper use of the product. SAFETY & WARNING INSTRUCTIONS ATTENTION - Observe valid and generally accepted safety rules when planning, installing and using this product. - Take proper measures to prevent unintentional operation of the product or damage to it. - Do not attempt to disassemble this product or lines in the system while they are under pressure. - Always depressurise the compressed air system before working on the system. It is important that personnel use safe working practices and observe all regulations and legal requirements for safety when operating this product. When handling, operating or carrying out maintenance on this product, personnel must employ safe engineering practices and observe all local health & safety requirements & regulations. International users refer to regulations that prevail within the country of installation. Most accidents, which occur during the operation and maintenance of machinery, are the result of failure to observe basic safety rules or precautions. An accident can often be avoided by recognising a situation that is potentially dangerous. Improper operation or maintenance of this product could be dangerous and result in an accident causing injury or death. The manufacturer cannot anticipate every possible circumstance, which may represent a potential hazard. The WARNINGS in this manual cover the most common potential hazards and are therefore not all-inclusive. If the user employs an operating procedure, an item of equipment or a method of working which is not specifically recommended by the manufacturer he must ensure that the product will not be damaged or made unsafe and that there is no risk to persons or property. GENERAL MAGNET SAFETY ATTENTION The magnets in the operator we use are extremely strong, and must be handled with care to avoid personal injury and damage to the magnets. Fingers and other body parts can get severely pinched between two attracting magnets. The strong magnetic fields of the magnets in the operator can also damage magnetic media such as floppy disks, credit cards, magnetic I.D. cards, cassette tapes, video tapes or other such devices. They can also damage televisions, VCRs, computer monitors and other CRT displays. Never place the operator near electronic appliances. Never allow magnets near a person with a pacemaker or similar medical aid. The strong magnetic fields of the magnets in the operator can affect the operation of such devices. The operator will lose its magnetic properties if heated above 175 F (80 C). 2

3 EXPLODED VIEW - Main parts Housing bolt (4*) Air plug Washer (4*) Air plug o-ring Test knob Housing front plate Test spring Strainer Valve mounting bolt (4*) Sight glas Test pin + valve O-ring Valve O-ring Air inlet top nut Inlet plug (2*) Valve/operator module Outlet nipple Sight glass gasket Housing back Strainer plug with O-ring Sight glass Housing gasket Sight glass screw (2*) Sight glass screw o-ring (2*) 3

4 EXPLODED VIEW - Valve/operator module Valve bolt (4*) Top nut air inlet Valve top part Plunger seal o-ring Plunger seal Valve plunger o-ring Air bypass plug Air bypass Plug o-ring Valve middle part Plunger spring Plunger stem Valve bottom part Operator Operator Shaft Operator Spring Operator Plunger Operator valve Screw (2*) Operator valve body Valve O-ring 4

5 MAINTENANCE INSTRUCTIONS 1. Close the condensate supply, i.e. close the ball valve which is installed in front of the NUFORS-DC. Depressurize the system before installation or maintenance is carried out! 2. Press and hold the TEST button to empty the unit of any residual condensate and to depressurise the NUFORS-DC. 3. Remove the outlet tube. 4. Remove the 4 housing bolts using a 6mm Allen key. 5. Remove the front plate with attached valve assembly. 6. Remove the test knob and underlying spring by screwing it off the test pin using your hands on the knob and Needle nose pliers on the back. 5

6 MAINTENANCE INSTRUCTIONS 7. Remove the 4 valve mounting bolts using a 3mm Allen key. 8. Take the valve assembly and O-rings off the front plate. 9. Remove the 4 valve bolts using a 3mm Allen key. 10. Take out the valve middle part and remove the plunger seal using needle nose pliers. Do not remove the plunger stem! 11.First clean and then lubricate the plunger seal O-ring and the chamber where you removed it from. 12. Screw the plunger seal back on to the plunger stem using needle nose pliers and move it up and down a couple of times. Make sure it moves easily. Note: the two holes for the pliers should be on top, do not over tighten! 6

7 MAINTENANCE INSTRUCTIONS 13. screw the three valve blocks back together using the 4 valve bolts. Make sure the three blocks line up perfectly straight at the front (where the O-rings are). 14. Screw the valve assembly back on to the front plate using a 3mm Allen key. Do not over tighten!. Make sure all 4 O-rings are positioned correctly. 15. replace the test spring and test knob and tighten them using your fingers on the test knob and needle nose pliers on the back. Tighten them as far as you can but make sure the test pin can still move when you press the button. 16. Replace the front plate with attached valve assembly on to the reservoir using the 4 housing bolts and a 6mm Allen key. 17. replace the outlet tube and tighten the clamp. 18. Your NUFORS-DC is ready for operation. Push the test button to check the valve function 7

Installation & Maintenance Instructions NUFORS G1/2 & G3/4. Pneumatically operated demand drain 04/08

Installation & Maintenance Instructions NUFORS G1/2 & G3/4. Pneumatically operated demand drain 04/08 Installation & Maintenance Instructions NUFORS G1/2 & G3/4 Pneumatically operated demand drain GENERAL OPERATION 04/08 The NUFORS removes condensate from compressed air systems. The operation is automatic

More information

Electronic Timer Drain and Filter Ball Valves. Operating Instructions Manual

Electronic Timer Drain and Filter Ball Valves. Operating Instructions Manual Operating Instructions Manual EN Electronic Timer Drain and Filter Ball Valves Models 12F742, 13X522-13X542, 38UC76, 38UC77, 38XR36, 38XR45, 38XR46, 38XR59, 38XR65, 38XR70, 38XR85, 38XT18, 38XT31, 38XT33,

More information

Free Float Air Trap G8

Free Float Air Trap G8 172-65193MA-06 (G8) 24 June 2015 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Free Float Air Trap G8 Copyright 2015 by TLV CO., LTD. All rights reserved 1

More information

Service Manual #67. Installation and Service Instructions 6000, 7000 & 8000 Series Magnetically Coupled Pumps

Service Manual #67. Installation and Service Instructions 6000, 7000 & 8000 Series Magnetically Coupled Pumps Service Manual #67 Installation and Service Instructions 6000, 7000 & 8000 Series Magnetically Coupled Pumps Table of Contents Section Description Page 1 General Description 4 2 The Pumping Principle 5

More information

KHR Series Regulators

KHR Series Regulators KHR Series Regulators Maintenance Instructions Kit Contents retainer Poppet Poppet spring Poppet damper Outer body seal Inner body seal Upper piston seal seal backup ring Main piston seal vent seal Self-vent

More information

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013.

Air Trap TATSU2. Copyright 2013 by TLV CO., LTD. All rights reserved ISO 9001/ ISO M-02 (TATSU2) 7 August 2013. 172-65177M-02 (TATSU2) 7 August 2013 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Air Trap TATSU2 Copyright 2013 by TLV CO., LTD. All rights reserved 1 Contents

More information

Float Dynamic Steam Trap J10

Float Dynamic Steam Trap J10 172-65237MA-01 (J10) 12 June 2015 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Float Dynamic Steam Trap J10 Copyright 2015 by TLV CO., LTD. All rights reserved

More information

Free Float Air Trap JA3 JAF3 / JA5 JAF5 JA7 / JA7.2 / JA7.5 / JA8

Free Float Air Trap JA3 JAF3 / JA5 JAF5 JA7 / JA7.2 / JA7.5 / JA8 172-65144MA-05 (JA Series) 29 July 2013 ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Free Float Air Trap JA3 JAF3 / JA5 JAF5 JA7 / JA7.2 / JA7.5 / JA8 Copyright

More information

A408 GB. Pneumatic oil and diesel pumps 1:1

A408 GB. Pneumatic oil and diesel pumps 1:1 03 594 A408 GB Pneumatic oil and diesel pumps 1:1 G Operating instructions for Pneumatic oil and diesel pump 1:1 Contents 1. General details 2 1.1 Intended use 2 1.2 Design and functional description 2

More information

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER CHR-1285/2485 BATTERY CHARGER TEL:886-4-2238-0698 FAX:886-4-2238-0891 Web Site:http://www.monicon.com.tw E-mail:sales@monicon.com.tw Copyright 2007 Monicon Instruments Co., Ltd. All right reserved. Contents

More information

Martin Air Cannon Maintenance Instructions

Martin Air Cannon Maintenance Instructions Martin Air Cannon Maintenance Instructions Go to Martin Air Cannon Maintenance Instructions web page Martin Hurricane Air Cannon Martin Tornado Air Cannon Operator s Manual M3747 Important MARTIN ENGINEERING

More information

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P P200-3100 SERIES PUMPS 18mm Versions Nickle-Aluminum Bronze Models: P217-3100, P218-3100, P219-3100, P220-3100, P221-3100, P227-3100, P230-3100 Triplex Ceramic Plunger Pump Operating Instructions/ Repair

More information

Plunger Heads Use and Maintenance Manual

Plunger Heads Use and Maintenance Manual Plunger Heads Use and Maintenance Manual UK Positive displacement dosing pump Type PDP Series A-I 175 A-I 250 A-I 350 General instructions We thank you for choosing this product and recommend you read

More information

APT10-2 Automatic Pump Trap

APT10-2 Automatic Pump Trap 6120050/3 IM-P612-18 ST Issue 3 APT10-2 Automatic Pump Trap Installation and Maintenance Instructions 1. General safety information 2. Product information 3. Installation Closed loop steam systems only

More information

Model CP420/CP425. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

Model CP420/CP425. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Model CP420/CP425 Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Updated 02/12 Contents: Installation Instructions: page 2 Pump Specifications: page 3 Exploded View: page

More information

Pneumatic grease pump 50:1 and grease supply system

Pneumatic grease pump 50:1 and grease supply system Pneumatic grease pump 50:1 and grease supply system 03 591 A411 GB G Operating instructions for Pneumatic grease pump 50:1 Contents 1. General Information 2 1.1 Usage Stipulations 2 1.2 Construction &

More information

TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingcom TECHNICAL SERVICE MANUAL abrasive liquid pumps SERIES 4625 SIZES f - fh SECTION TSM 410.1 PAGE 1

More information

PRODUCT OBSOLETED 4Q16

PRODUCT OBSOLETED 4Q16 Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingcom TECHNICAL SERVICE MANUAL abrasive liquid pumps SERIES 4625 SIZES f - fh SECTION TSM 410.1 PAGE 1

More information

Disassembly and Assembly

Disassembly and Assembly K EN R 623 2-00 August 2006 Disassembly and Assembly 2506-15 Industrial Engine M G A (Engine) MGB (Engine) M G D (Engine) Important Safety Information Most accidents that involve product operation, maintenance

More information

Installation Manual DIAPHRAGM WELL TANK

Installation Manual DIAPHRAGM WELL TANK Installation Manual DIAPHRAGM WELL TANK IN-LINE SERIES: 2-5 & 7 GALLON VERTICAL SERIES: 14-20-25-32-36-52-65-86-96-119 GALLON HORIZONTAL SERIES: 7-14 & 20 GALLON NO LEAD NO LEAD: The weighted average of

More information

Series CP200. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual. For Models: CP218 CP219 CP220 CP230

Series CP200. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual. For Models: CP218 CP219 CP220 CP230 Series CP200 Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual For Models: CP218 CP219 CP220 CP230 Updated 10/02 Contents: Installation Instructions: page 2 Pump Specifications:

More information

Miniature Soft Seat Fluid Pressure Regulator

Miniature Soft Seat Fluid Pressure Regulator Instruction Sheet P/N 1. Description The Nordson miniature soft seat fluid pressure regulator is designed for use with hydraulic and pneumatic medias. The regulator body and wetted parts are constructed

More information

BIG BLASTER Air Cannon Maintenance Instructions

BIG BLASTER Air Cannon Maintenance Instructions BIG BLASTER Air Cannon Maintenance Instructions Go to BIG BLASTER Air Cannon Maintenance Instructions web page BIG BLASTER HURRICANE Air Cannon BIG BLASTER XHV Air Cannon with MARTIN TORNADO Exhaust Valve

More information

HEAVY DUTY PNEUMATIC TORQUE WRENCH (C-RAD) USER GUIDE

HEAVY DUTY PNEUMATIC TORQUE WRENCH (C-RAD) USER GUIDE HEAVY DUTY PNEUMATIC TORQUE WRENCH (C-RAD) USER GUIDE Ref: WCOI.041 Date: June 2015 Issue: 4 Page Description CONTENTS 1 Introduction Training Requirements 2 General Safety 3 C-RAD Wrench Models Covered

More information

BAYLIFT SERVICE MANUAL

BAYLIFT SERVICE MANUAL -PRINT- MARCH 2014 - TABLE OF CONTENTS- INTRODUCTION I. INTRODUCTION T he RICON BayLift Public Use wheelchair lift is intended to provide wheelchair access to public vehicles including buses, school buses,

More information

Easy-On Wireless Tail Lights User s Guide

Easy-On Wireless Tail Lights User s Guide Easy-On Wireless Tail Lights User s Guide TAKE NOTICE: BY INSTALLING OR OTHERWISE USING THE EASY-ON WIRELESS TAIL LIGHTS YOU AGREE TO FOLLOW THE BELOW DIRECTIONS CAREFULLY AND BE BOUND BY THE LIMITATION

More information

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

Installation and operating manual Quick closing valve (Bellow sealed) LK product no: LK product no: 902002 Article no: 74506 Revision: 2 Contents 1. General information... 3 2. Safety precautions... 3 2.1 Significance of symbols... 3 2.2 Explanatory notes on safety information... 3 3.

More information

Ph: (07) Fax: (07) Pump Manual

Ph: (07) Fax: (07) Pump Manual sales@scintex.com.au www.scintex.com.au Ph: (07) 3137 0135 Fax: (07) 3041 0541 Pump Manual 12V 75LPM Vane Pump & Vane Pump Station SPEP12V75 & SP12VFS75 SPEP12V75 SP12VFS75 Parts List No. Part Name QTY

More information

1 MECHANICAL FUEL METER

1 MECHANICAL FUEL METER 1 MECHANICAL FUEL METER USER S MANUAL WARNING: Read carefully and understand all INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety precautions may result in serious

More information

Trail-Creeper Dual Transfer Case Adapter

Trail-Creeper Dual Transfer Case Adapter Trail-Creeper Dual Transfer Case Adapter Installation Instructions For Kits: 100001-1-KIT 21 Spline 100006-1-KIT 23 Spline KIT Contents: 23 or 21 Spline Coupler 1.0 Adapter Plate w/ Bearings Installed

More information

H2O-C14 AAA FINE FINISH SERIES PUMP OUTFIT

H2O-C14 AAA FINE FINISH SERIES PUMP OUTFIT PRODUCT INFORMATION H2O-C14 AAA FINE FINISH SERIES PUMP OUTFIT The H2O-C14 AAA pump system is an air assisted airless unit which combines airless and conventional or HVLP air atomization technologies to

More information

Manufacturer Kakogawa, Japan DC5S

Manufacturer Kakogawa, Japan DC5S ISO 9001/ ISO 14001 Manufacturer Kakogawa, Japan is approved by LRQA LTD. to ISO 9001/14001 Cyclone Separator Trap DC5S Copyright 2015 by TLV Co., Ltd. All rights reserved 1 Contents Introduction... 1

More information

Technical Manual. DLM Module. This manual should remain with the unit.

Technical Manual. DLM Module. This manual should remain with the unit. Technical Manual DLM Module This manual should remain with the unit. Safety Rules SAVE THESE INSTRUCTIONS! Read the following information carefully before attempting to install, operate or service this

More information

Owner's/Installation Manual

Owner's/Installation Manual Owner's/Installation Manual Power Management Module (PMM) and Starter Kit NOTE: The starter kit must be purchased and installed prior to individual PMM usage. Model Numbers: 00686-0 PMM 00699-0 PMM WITH

More information

Dome-Loaded Pressure Reducing BD-Series

Dome-Loaded Pressure Reducing BD-Series Dome-Loaded Pressure Reducing BD-Series *Parts will differ for high pressure valves. Load Piston - Piston - U-cup U-cup Piston 1. Carefully place the u-cup over the neck of the piston. Load Cylinder -

More information

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P

MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P MANUAL NUMBER P-EFS-1 MAINTENANCE MANUAL FOR THERMOSTATIC TEMPERATURE REGULATING VALVE TRAC STYLE P TRAC Regulator Company Inc. 160 South Terrace Avenue Mount Vernon, New York USA 10550-2408 Phone: (914)

More information

OFFICINE OROBICHE S.p.A. 1/7 INSTRUCTION MANUAL FOR FLOW SWITCHES PL SERIES

OFFICINE OROBICHE S.p.A. 1/7 INSTRUCTION MANUAL FOR FLOW SWITCHES PL SERIES OFFICINE OROBICHE S.p.A. 1/7 INSTRUCTION MANUAL FOR FLOW SWITCHES PL SERIES 1.INSTRUMENT DESCRIPTION Flow switches PL series are designed to be mounted in an upright position along horizontal pipes. These

More information

IMPORTANT SAFETY NOTICE

IMPORTANT SAFETY NOTICE IMPORTANT SAFETY NOTICE To: Our Valued Customers User safety is a major focus in the design of our products. Following the precautions outlined in this manual will minimize your risk of injury. ITT Goulds

More information

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions. FL 10 INSTALLATION INSTRUCTIONS DIAPHRAGM PUMP FL 10 DC-P FL 10 AC Before operating the pump, please read the Installation Instructions and safety precautions. Installation Instructions FL 10 Table of

More information

OWNER S MANUAL MiniBoost

OWNER S MANUAL MiniBoost A Brand OWNER S MANUAL MiniBoost www.teambmpro.com CONTENTS Safety Precautions 3 About the MiniBoost 4 Installation 4 Personnel 4 Ventilation, Orientation, and Thermal Considerations 4 Mounting 5 Wiring

More information

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil Type 3535 Three-way Valve with bellows seal and rod-type yoke (partial view) Mounting and Operating Instructions EB 8135/8136 EN Edition

More information

IAG Street Series Air / Oil Separator (AOS) For WRX & WRX STI

IAG Street Series Air / Oil Separator (AOS) For WRX & WRX STI IAG Street Series Air / Oil Separator (AOS) For 2006-07 WRX & 2004-07 WRX STI Part# IAG-ENG-7150 Tools Required: Ratchet, torque wrench, extensions, needle nose pliers, hose cutter, snips/scissors, flat

More information

CompoSeal butterfly valves, wafer style Installation & Maintenance Instructions

CompoSeal butterfly valves, wafer style Installation & Maintenance Instructions Please read these instructions carefully This symbol indicates important messages and safety instructions. Intended valve use The valve is intended to be used only in applications within the pressure/temperature

More information

Quick-Disconnect Coupling one-hand operation Push Pull ND 5, connecting thread G 1/4,max. operating pressure 500 bar

Quick-Disconnect Coupling one-hand operation Push Pull ND 5, connecting thread G 1/4,max. operating pressure 500 bar Issue 12-2013 Quick-Disconnect Coupling one-hand operation Push Pull ND 5, connecting thread G 1/4,max. operating pressure 500 bar Figure 1: Coupling complete Figure 4: Coded coupling, complete Table of

More information

PNEUMATIC TORQUE WRENCH (C-RAD) USER GUIDE

PNEUMATIC TORQUE WRENCH (C-RAD) USER GUIDE PNEUMATIC TORQUE WRENCH (C-RAD) USER GUIDE Ref: WCOI.031 Date: Mar 2017 Issue: 10 Page Description CONTENTS 1 Introduction Training Requirements 2 General Safety 3 C-RAD Wrench Models Covered By Manual

More information

Maintenance Information

Maintenance Information 16573321 Edition 3 February 2014 Air Grinder Series 61H Maintenance Information Save These Instructions Product Safety Information WARNING Failure to observe the following warnings, and to avoid these

More information

IAG Street Series Air / Oil Separator (AOS) For WRX & WRX STI

IAG Street Series Air / Oil Separator (AOS) For WRX & WRX STI IAG Street Series Air / Oil Separator (AOS) For 2006-07 WRX & 2004-07 WRX STI Part# IAG-ENG-7100 Tools Required: Ratchet, torque wrench, extensions, needle nose pliers, hose cutter, snips/scissors, flat

More information

Models P420A-3100 & P420A-5100

Models P420A-3100 & P420A-5100 Models P420A-3100 & P420A-5100 Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual Corrossion Resistant Pumps Contents: Installation Instructions: page 2 Specifications: page

More information

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS

PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS PRODUCT SERVICE MANUAL FOR BK12DHZ PUMPS WARNING This manual, and the GENERAL INSTRUCTION MANUAL SRM00046, should be read thoroughly prior to pump installation, operation or maintenance. Manual No. SRM00095

More information

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS X-SERIES TRIPLEX CERAMIC PLUNGER PUMPS OPERATING MANUAL MODELS X8 X10 X20 IMPORTANT OPERATING CONDITIONS Failure to comply with any of these conditions invalidates the warranty. Lubrication - Prior to

More information

Intended Use: Explanation of Signal Word Consequences

Intended Use: Explanation of Signal Word Consequences SAFETY INFORMATION & INSTRUCTION MANUAL Please read, understand, and follow all safety information contained in these instructions prior to the use of this device. Retain these instructions for future

More information

INSTRUCTION MANUAL FOR SAMSON GAMMA UNITS, TYPES: GAMMA 10, -20, -30, -40, -50, -60, -70, -90, -100

INSTRUCTION MANUAL FOR SAMSON GAMMA UNITS, TYPES: GAMMA 10, -20, -30, -40, -50, -60, -70, -90, -100 TRUCKS FOOD OFFSHORE FISH SAMSON LIQUID RING VACUUM PUMPS INSTRUCTION MANUAL FOR SAMSON GAMMA UNITS, TYPES: GAMMA 10, -20, -30, -40, -50, -60, -70, -90, -100 DOC3700C INDUSTRY GAMMA UNITS 2 CONTENTS 1

More information

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use! Operating instructions Pneumatic Crimper AC 100 Date of issue: 05/2010 Keep for future use! SAFETY SAFETY Basic information The basic prerequisite for ensuring safe use and continuous operation of the

More information

Opti Line ACG8 Screw pump Maintenance & Start up Instruction

Opti Line ACG8 Screw pump Maintenance & Start up Instruction Opti Line ACG8 Screw pump Maintenance & Start up Instruction Introduction A screw pump from IMO is a quality product that is designed for a long problem free operation in tough environments. As all other

More information

DELUXE TELESCOPING LANCE ASSEMBLY

DELUXE TELESCOPING LANCE ASSEMBLY DELUXE TELESCOPING LANCE ASSEMBLY Products Part # Lenght Inlet Outlet 27.0080 18 3/8 Plug 1/4" QC F 27.0082 24 3/8 Plug 1/4" QC F The product come supplied with: - Non Molded Extension Wand M22 Male Inlet

More information

CONGRATULATIONS. on your purchase of a Viridian Grip Laser, the most advanced sighting device available.

CONGRATULATIONS. on your purchase of a Viridian Grip Laser, the most advanced sighting device available. GRIP LASER MANUAL CONGRATULATIONS on your purchase of a Viridian Grip Laser, the most advanced sighting device available. IF YOU HAVE TECHNICAL OR SERVICE ISSUES WITH THIS LASER, DO NOT RETURN TO PRODUCT

More information

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions INSTALLATION AND MAINTENANCE INSTRUCTIONS IM-8-002-US October 2016 Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions These instructions should be read by the Company

More information

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico:

MicroCoat. System Operating Manual MC2000 Series. MC785, MC785-WF Spray Valves. US: UK: Mexico: MicroCoat System Operating Manual MC2 Series MC785, MC785-WF Spray Valves A NORDSON COMPANY US: 8-498-8865 UK: 8 585733 Mexico: 1-8-556-3484 Introduction The MicroCoat System provides precise lubrication

More information

Type 644 and 645 Differential Pressure Pump Governors

Type 644 and 645 Differential Pressure Pump Governors Instruction Manual 644 and 645 Pump Governors Type 644 and 645 Differential Pressure Pump Governors Introduction Scope of Manual This instruction manual provides information on installation, adjustment,

More information

HALLMARK INDUSTRIES INC

HALLMARK INDUSTRIES INC Performance Part No. HP. CONVERTIBLE JET PUMP USER S MANUAL GPH of Water @ Total Discharge Pressure of 40 psi Max. Pressure Max suction (shallow well) Max Suction (deep well) Max GPM (@0 head) Max Discharge

More information

Installation, Maintenance, & Repair Series 995 Reduced Pressure Zone Backflow Preventers

Installation, Maintenance, & Repair Series 995 Reduced Pressure Zone Backflow Preventers Installation, Maintenance, & Repair Series 995 Reduced Pressure Zone Backflow Preventers RP/IS-995 Sizes: 2" through 2" (5-50mm)! WARNING Read this Manual BEFORE using this equipment. Failure to read and

More information

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding Installation, Operating, Maintenance & Safety Instruction for M PUMPS CM MAG-M SERIES Centrifugal light Mag-Drive pumps (CM MAG-M06/1/2/3/4) This manual presents installation, servicing, troubleshooting,

More information

IAG Air / Oil Separator (AOS) For STi

IAG Air / Oil Separator (AOS) For STi IAG Air / Oil Separator (AOS) For 2008-14 STi Part# IAG-ENG-7000 Tools Required: Ratchet, torque wrench, extensions, needle nose pliers, hose cutter, snips/scissors Sockets: 10mm, 12mm 13mm Wrenches: 10mm,

More information

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1

CONTENTS. VIKING PUMP, INC. A Unit of IDEX Corporation Cedar Falls, IA USA SECTION TSM 710.1 TECHNICAL SERVICE MANUAL industrial heavy duty motor speed pumps SERIES 4076 AND 4176 SIZES hle, ate and ale SECTION TSM 710.1 PAGE 1 of 8 ISSUE B CONTENTS Introduction....................... 1 Safety

More information

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i) USER MANUAL NEMA 48C Flange Mounted, Enclosed, Clutch Brake FMCBE Model 500 (i) In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual

More information

Installation Instructions

Installation Instructions Instructions Aerada 90-75 Series Metering Faucet S53-053 90-75 Series Metering Faucet with 4" Centerset S53-082 90-75 Series Metering Faucet with 4" Centerset & 8" Trim Plate S53-058 90-75 Series Metering

More information

Operation and Maintenance Manual

Operation and Maintenance Manual BM / BMA Hydrometers ½ Operation and Maintenance Manual i This manual is intended for use by the users of this equipment. The information contained herein is the property of the Arad Ltd. Dalia and may

More information

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS:

INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS: INSTRUCTION MANUAL INTERNAL GEAR PUMP TITAN G-4124A SERIES=> FLANGED TITAN G-124A SERIES => FLANGED MODELS: G-H, G-HL, G-K, G-KK, G-L, G-LQ, G-LL, GLS, G-Q, G-QS 1 Contents Maintenance Thrust bearing adjustment

More information

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions 4034450/9 IM-P403-15 AB Issue 9 BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions 1. Safety information 2. Application 3. Technical data 4. Operation 5. Installation 6. Rotating

More information

Series. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual P200-18mm versions

Series. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual P200-18mm versions Series Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual P200-18mm versions For Models: P217 P218 P219 P220 P221 P227 P230 Updated 05/18 Contents: Page Installation Instructions:

More information

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual

Model GXR Series. Consumer Pump. Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual Model GXR Series Triplex Plunger Pump Operating Instructions/ Repair Instructions Manual Consumer Pump Horizontal/Vertical Pump with built-in Regulator, Thermal Relief Valve and Siphon Injector MADE IN

More information

operating instruction

operating instruction operating instruction a.560pn #125101 DE, EN, FR, SE Table of Contents Installation... 3 Tool use...4-5 Safety precautions...6-7 Troubleshooting and maintenance... 8 Technical specification... 9 Spare

More information

FCB-450, LCB-600, MCB-800

FCB-450, LCB-600, MCB-800 AIR CHAMP PRODUCTS User Manual FCB-450, LCB-600, MCB-800 Clutch-Brakes (i) In accordance with Nexen s established policy of constant product improvement, the specifications contained in this manual are

More information

BW - BIG VOLUME BOOSTER INSTRUCTION MANUAL 2072

BW - BIG VOLUME BOOSTER INSTRUCTION MANUAL 2072 BW - BIG VOLUME BOOSTER INSTRUCTION MANUAL 2072 STI S.r.l has taken every care in collecting and verifying the documentation contained in this Instruction Manual. The information herein contained are reserved

More information

TECHNICAL SERVICE MANUAL INSTALLATION, START UP, TROUBLESHOOTING, SERIES SG-04, SG-05 & SG-07 spur gear PUMPS

TECHNICAL SERVICE MANUAL INSTALLATION, START UP, TROUBLESHOOTING, SERIES SG-04, SG-05 & SG-07 spur gear PUMPS Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com TECHNICAL SERVICE MANUAL SECTION TSM 340 PAGE 1 OF 10 ISSUE G INSTALLATION, START UP, TROUBLESHOOTING,

More information

IAG Street Series Air / Oil Separator (AOS) For WRX & WRX STI

IAG Street Series Air / Oil Separator (AOS) For WRX & WRX STI IAG Street Series Air / Oil Separator (AOS) For 2006-07 WRX & 2004-07 WRX STI Part# IAG-ENG-7150 Tools Required: Ratchet, torque wrench, extensions, needle nose pliers, hose cutter, snips/scissors, flat

More information

Variable Speed Misting Pump Totally Enclosed Direct Drive MODEL HDE-1PH-230VFD

Variable Speed Misting Pump Totally Enclosed Direct Drive MODEL HDE-1PH-230VFD Variable Speed Misting Pump Totally Enclosed Direct Drive MODEL 60100-HDE-1PH-230VFD SAFETY, GENERAL INFORMATION, ELECTRICAL DEFINITIONS WARNING CAN cause DEATH, SEVERE INJURY or substantial property damage.

More information

Mod: KLD6-12/35XLAS-N

Mod: KLD6-12/35XLAS-N 12/2011 Mod: KLD6-12/35XLAS-N Production code: 1914070 INSTRUCTION MANUAL LOGIC LINE PLUS HOOD Reseller Stamp for Warranty Dear customer, Above all, thank you for choosing our product and we would like

More information

SAFETY INFORMATION & INSTRUCTION MANUAL

SAFETY INFORMATION & INSTRUCTION MANUAL SAFETY INFORMATION & INSTRUCTION MANUAL Please read, understand, and follow all safety information contained in these instructions prior to the use of this device. Retain these instructions for future

More information

PRODUCT OPERATING MANUAL

PRODUCT OPERATING MANUAL PRODUCT OPERATING MANUAL PANBLAST TM BP300-1 BLAST POT Manual Number: ZVP-PC-PB-0014 SECTION 1. GENERAL INFORMATION 2. INITIAL SETUP INSTRUCTIONS 3. OPERATING INSTRUCTIONS 4. MAINTENANCE 5. TROUBLE SHOOTING

More information

PRODUCT SERVICE MANUAL. BK6DHZ(C)-250, 275, 312 and 400 PUMPS

PRODUCT SERVICE MANUAL. BK6DHZ(C)-250, 275, 312 and 400 PUMPS PRODUCT SERVICE MANUAL BK6DHZ(C)-250, 275, 312 and 400 PUMPS WARNING This manual, and the GENERAL INSTRUCTION MANUAL, SRM00046, should be read thoroughly prior to pump installation, operation or maintenance.

More information

TM SERIES MIXER TMS OPERATION & PARTS MANUAL

TM SERIES MIXER TMS OPERATION & PARTS MANUAL TM SERIES MIXER TMS OPERATION & PARTS MANUAL EU Declaration of Conformity Finish Thompson Inc. hereby declares that the following machine(s) fully comply with the applicable health and safety requirements

More information

Disassembly and Assembly

Disassembly and Assembly SENR9973-01 September 2007 Disassembly and Assembly 400C Industrial Engine HB (Engine) HD (Engine) HH (Engine) HL (Engine) HM (Engine) HN (Engine) HP (Engine) HR (Engine) Important Safety Information Most

More information

1 of 1 5/6/2016 7:30 AM

1 of 1 5/6/2016 7:30 AM Battery, Hybrid Drive Service and Repair, Procedures: Battery Module... http://repair.alldata.com/alldata/article/display.action?componentid=377... 1 of 1 5/6/2016 7:30 AM Battery Module Replacement NOTE:

More information

SELF PRIMING CHEMICAL SERVICE PUMPS

SELF PRIMING CHEMICAL SERVICE PUMPS SELF PRIMING CHEMICAL SERVICE PUMPS INSTALLATION AND OPERATING INSTRUCTIONS This Manual covers: SELF PRIMING MODEL RANGE J50ECX TO J250ECX STAINLESS STEEL*, and NON METALLIC SEAL PUMP MODEL: SERIAL NO:

More information

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

4 ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause 4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL BEFORE INSTALLING PUMP, BE SURE TO READ THIS OWNER S MANUAL CAREFULLY. CAUTION Fill pump with water before starting or pump will be damaged. The motor on

More information

PRODUCT OPERATING MANUAL

PRODUCT OPERATING MANUAL PRODUCT OPERATING MANUAL PANBLAST TM BP110 3 BLAST POT Manual Number: ZVP PC 0155 00 SECTION 1. GENERAL INFORMATION 2. INITIAL SETUP INSTRUCTIONS 3. OPERATING INSTRUCTIONS 4. MAINTENANCE 5. TROUBLE SHOOTING

More information

80 Litre Suction Oil Drainer With Inspection Chamber

80 Litre Suction Oil Drainer With Inspection Chamber Please dispose of packaging for the product in a responsible manner. It is suitable for recycling. Help to protect the environment, take the packaging to the local amenity tip and place into the appropriate

More information

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM 150 150 150 This instruction manual contains proprietary information which is protected by copyright laws. No part of

More information

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 EN Operating manual Motorised zone valve Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 This manual ensures safe and efficient use of the 3PV2 or 3PV8 force-actuated three-way valve with spring-loaded return

More information

Wrenches: ⅞, 8mm, 10mm, 13mm, 19mm P. allen, Other: Electrical Tape

Wrenches: ⅞, 8mm, 10mm, 13mm, 19mm P. allen, Other: Electrical Tape IAG Street Series Air / Oil Separator (AOS) For 2008-14 STI Part# IAG-ENG-7100 Tools Required: Ratchet, torque wrench, extensions, needle nose pliers, hose cutter, snips/scissors, flat head screw driver,

More information

DODGE COOL LUBE 2 for Sleevoil Pillow Blocks Part Numbers , , ,

DODGE COOL LUBE 2 for Sleevoil Pillow Blocks Part Numbers , , , DODGE COOL LUBE for Sleevoil Pillow Blocks Part s 063487, 063488, 07889, 07890 These instructions must be read thoroughly before installing or operating this product. WARNING: To ensure the drive is not

More information

MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES

MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES Size Range 2 48 ASME Classes 150-2500 *It is recommended that the valve installer is familiar with

More information

US Water ph Booster-Reducer Injection System

US Water ph Booster-Reducer Injection System US Water ph Booster-Reducer Injection System 410-PHBOOST 410-PHREDUCER US Water Systems, Inc. 1209 Country Club Road Indianapolis, IN 46234 1-800-608-8792 info@uswatersystems.com www.uswatersystems.com

More information

HYDRAULIC PUMP. INSTALLATION, OPERATION, & MAINTENANCE MANUAL MAINTENANCE MANUAL #: MM-HP Rev. A Page 1 of 12

HYDRAULIC PUMP. INSTALLATION, OPERATION, & MAINTENANCE MANUAL MAINTENANCE MANUAL #: MM-HP Rev. A Page 1 of 12 INSTALLATION, OPERATION, & #: MM-HP001 4-20-09 Rev. A Page 1 of 12 HYDRAULIC PUMP PART NUMBER HP46982ALSL & HP46982SL HYDRAULIC PUMP MM-HP001 Rev. A Page 2 of 12 Table of Contents 1.0 General Page 3 2.0

More information

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Air Operated Diaphragm Pumps Operating and Maintenance Instructions Product & Chemical Disclaimer The user must take responsibility in the selection of the products materials of construction. Empire Pumps Ltd will act in an advisory role and offer recommendations; however,

More information

TECHNICAL SERVICE MANUAL

TECHNICAL SERVICE MANUAL Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com TECHNICAL SERVICE MANUAL industrial heavy duty motor speed pumps SERIES 4076 AND 4176 SIZES

More information

CONDENSER-NEEDLE COIL CLEANER OPERATING AND MAINTENANCE INSTRUCTIONS

CONDENSER-NEEDLE COIL CLEANER OPERATING AND MAINTENANCE INSTRUCTIONS CONDENSER-NEEDLE COIL CLEANER OPERATING AND MAINTENANCE INSTRUCTIONS Copyright 2012 SpeedClean., Stamford, CT U.S.A. Effective Date: June 15, 2015 SpeedClean is a registered trademark of Crossford International.

More information

Installation and operating manual

Installation and operating manual LK product no: 901002 and 901102 501002 and 501102 (JIS) Article no: 74500 Revision: 9 Article no: 74500 Revision: 9 2 (23) Contents 1. General information... 5 2. Safety precautions... 5 2.1 Significance

More information

Model Repair Parts Sheet SPECIFICATIONS. Stake threads lightly after assembly. Note: Pump base is not available as a service item.

Model Repair Parts Sheet SPECIFICATIONS. Stake threads lightly after assembly. Note: Pump base is not available as a service item. Repair Parts Sheet Model 10508 SPECIFICATIONS Operating Pressure Relief Valve Setting Oil Volume per Stroke Reservoir Capacity 10,000 psi max. 10,000 psi 0.1595 cu. in. 43 cu. in. Use a 3/16 hex wrench

More information