The Annubar Flowmeter Series. Rosemount 3051SFA ProBar Flowmeter. Product Data Sheet , Rev EA Catalog

Size: px
Start display at page:

Download "The Annubar Flowmeter Series. Rosemount 3051SFA ProBar Flowmeter. Product Data Sheet , Rev EA Catalog"

Transcription

1 , Rev EA Rosemount 3051SFA ProBar Flowmeter SPECIFICATIONS Performance System Reference Accuracy Percentage (%) of volumetric flow rate Classic Ultra Ultra for Flow (8:1 flow turndown) (8:1 flow turndown) (10:1 flow turndown) ±1.10% ±0.90% ±0.80% Repeatability ±0.1% Line Sizes Sensor Size 1: 2-in. to 8-in. (50 to 200 mm) Sensor Size 2: 6-in. to 96-in. (150 to 200 mm) Sensor Size 3: 12-in. to 96-in. (300 to 200 mm) NOTE Some mounting types are not available in larger line sizes. TABLE 1. Reynolds Number and Probe Width Sensor Size Output Minimum Rod Reynolds Number (R d ) Probe Width ( d ) in. (1.99 mm) in. (26.92 mm) in. (9.15 mm) d V p R d = Where d = Probe width (feet) V = Velocity of fluid (ft/sec) p = Density of fluid (lb m /ft 3 ) = Viscosity of the fluid (lb m /ft-sec) HART 20 ma ADC, flow rate output. Digital HART protocol superimposed on 20 ma signal, available to any host that conforms to the HART protocol. FOUNDATION Fieldbus (output code F) 17.5 ma for all configurations (including LCD display option) Performance Statement Assumptions Measured pipe I.D Electronics are trimmed for optimum flow accuracy Sizing Contact an Emerson Process Management representative for assistance. A Configuration Data Sheet is required prior to order for application verification. Annubar Sensor Surface Finish The front surface of the Annubar primary is textured for high Reynolds number applications (typically gas and steam). The surface texture creates a more turbulent boundary layer on the front surface of the sensor. The increased turbulence produces a more predictable and repeatable separation of flow at the edge of the sensor. The appropriate surface finish will be determined for each application by the Emerson Process Management sizing program. Functional Service Liquid Gas Steam 20 ma/hart Zero and Span Adjustment Zero and span values can be set anywhere within the range. Span must be greater than or equal to the minimum span. Output Two-wire 20 ma is user-selectable for linear or square root output. Digital process variable superimposed on 20 ma signal, available to any host that conforms to the HART protocol. Power Supply External power supply required. Standard transmitter ( 20 ma): 10.5 to 2. V dc with no load 3051S SIS Safety transmitter: 12 to 2 Vdc with no load 3051S HART Diagnostics transmitter: 12 to 2 Vdc with no load

2 , Rev EA The Annubar Flowmeter Series Load Limitations Maximum loop resistance is determined by the voltage level of the external power supply, as described by: Standard Transmitter Maximum Loop Resistance = 3.5 * (Power Supply Voltage 10.5) Load (Ohms) Operating Region Voltage (V dc) 2. The HART communicator requires a minimum loop resistance of 250 for communication. 3051S SIS Safety Transmitter (output code B) 3051S HART Diagnostics Transmitter (option code DA1) Maximum Loop Resistance = 3.5 * (Power Supply Voltage 12.0) Load (Ohms) Operating Region Voltage (V dc) 2. The HART communicator requires a minimum loop resistance of 250 for communication. HART Diagnostics Suite (Option DA1) The 3051S HART Diagnostics Transmitter provides Abnormal Situation Prevention (ASP) indication, device operating hours, variable logging, loop output readback diagnostic, and enhanced EDDL graphic displays for easy visual analysis. The integral statistical process monitoring (SPM) technology calculates the mean and standard deviation of the process variable 22 times per second and makes them available to the user. The 3051S ASP algorithm uses these values and highly flexible configuration options for customization to detect many user-defined or application specific abnormal situations (e.g. plugged impulse line detection). The device operating hours are logged along with the occurrence of diagnostic events to enable quick troubleshooting of application and installation issues. FOUNDATION fieldbus Power Supply External power supply required; transmitters operate on 9.0 to 32.0 V dc transmitter terminal voltage. Current Draw 17.5 ma for all configurations (including LCD display option) FOUNDATION fieldbus Parameters Schedule Entries Links Virtual Communications Relationships (VCR) 1 (max.) 30 (max.) 20 (max.) Standard Function Blocks Resource Block Contains hardware, electronics, and diagnostic information. Transducer Block Contains actual sensor measurement data including the sensor diagnostics and the ability to trim the pressure sensor or recall factory defaults. LCD Block Configures the local display. 2 Analog Input Blocks Processes the measurements for input into other function blocks. The output value is in engineering or custom units and contains a status indicating measurement quality. PID Block with Auto-tune Contains all logic to perform PID control in the field including cascade and feedforward. Auto-tune capability allows for superior tuning for optimized control performance. Backup Link Active Scheduler (LAS) The transmitter can function as a Link Active Scheduler if the current link master device fails or is removed from the segment. Software Upgrade in the Field Software for the 3051S with FOUNDATION fieldbus is easy to upgrade in the field using the FOUNDATION fieldbus Common Device Software Download procedure. PlantWeb Alerts Enable the full power of the PlantWeb digital architecture by diagnosing instrumentation issues, communicating advisory, maintenance, and failure details, and recommending a solution. Advanced Control Function Block Suite (Option A01) Input Selector Block Selects between inputs and generates an output using specific selection strategies such as minimum, maximum, midpoint, average, or first good. Arithmetic Block Provides pre-defined application-based equations including flow with partial density compensation, electronic remote seals, hydrostatic tank gauging, ratio control and others. Signal Characterizer Block Characterizes or approximates any function that defines an input/output relationship by configuring up to twenty X, Y coordinates. The block interpolates an output value for a given input value using the curve defined by the configured coordinates. Integrator Bock Compares the integrated or accumulated value from one or two variables to pre-trip and trip limits and generates discrete output signals when the limits are reached. This block is useful for calculating total flow, total mass, or volume over time. 5

3 , Rev EA Output Splitter Block Splits the output of one PID or other control block so that the PID will control two valves or other actuators. Control Selector Block Selects one of up to three inputs (highest, middle, or lowest) that are normally connected to the outputs of PID or other control function blocks. Block Execution Time Resource - Transducer - LCD Block - Analog Input 1, 2 20 milliseconds PID with Auto-tune 25 milliseconds Input Selector 20 milliseconds Arithmetic 20 milliseconds Signal Characterizer 20 milliseconds Integrator 20 milliseconds Output Splitter 20 milliseconds Control Selector 20 milliseconds Fully Compensated Mass Flow Block (Option H01) Calculates fully compensated mass flow based on differential pressure with external process pressure and temperature measurements over the fieldbus segment. Configuration for the mass flow calculation is easily accomplished using the Rosemount 3095 Engineering Assistant. FOUNDATION fieldbus Diagnostics Suite (Option D01) 3051S FOUNDATION fieldbus Diagnostics provide Abnormal Situation Prevention (ASP) indication and enhanced EDDL graphic displays for easy visual analysis. The integral statistical process monitoring (SPM) technology calculates the mean and standard deviation of the process variable 22 times per second and makes them available to the user. The 3051S ASP algorithm uses these values and highly flexible configuration options for customization to detect many user-defined or application specific abnormal situations (e.g. plugged impulse line detection). Process Temperature Limits Direct Mount Electronics 500 F (260 C) 750 F (00 C) when used with a direct mount, high temperature 5-valve manifold (Electronics Connection Platform code 6) Remote Mount Electronics 1250 F (677 C) Hastelloy Sensor Material 850 F (5 C) Stainless Steel Sensor Material Electronics Temperature Limits Ambient 0 to 185 F ( 0 to 85 C) With Integral Mount LCD Display: to 175 F ( 20 to 80 C) Storage 50 to 230 F ( 6 to 110 C) With Integral Mount LCD Display: 0 to 185 F ( 0 to 85 C) Pressure Limits (1) Direct Mount Electronics Pressure retention per ANSI B # or DIN PN Static Pressure Limits Range 1A: Operates within specification between static line pressures of 0.5 psia to 2000 psig (0.03 to 138 bar) Ranges 2A 3A: Operates within specifications between static line pressures of 0.5 psia and 3626 psig (0.03 bar-a to 250 bar-g) Burst Pressure Limits Coplanar or traditional process flange psig (689,5 bar). Overpressure Limits Flowmeters withstand the following limits without damage: Range 1A: 2000 psig (138 bar) Ranges 2A 3A: 3626 psig (250 bar) TABLE 2. Overpressure Limits (1) Standard Type Humidity Limits 0 100% relative humidity Carbon Steel Rating Stainless Steel Rating ANSI/ASME Class (20) 275 (19) ANSI/ASME Class (51) 720 (50) ANSI/ASME Class (102) 10 (99) At 100 F (38 C), the rating decreases with increasing temperature. DIN PN 10/0 580 (0) 580 (0) DIN PN 10/ (16) 232 (16) DIN PN 25/0 580 (0) 580 (0) At 28 F (120 C), the rating decreases with increasing temperature. (1) Carbon Steel and Stainless Steel Ratings are measured in psig (bar). Turn-On Time Performance within specifications less than 2 seconds (typical) after power is applied to the transmitter Damping Analog output response to a step input change is user-selectable from 0 to 60 seconds for one time constant. This software damping is in addition to sensor module response time Failure Mode Alarm HART -20mA (output option codes A and B) If self-diagnostics detect a gross transmitter failure, the analog signal will be driven offscale to alert the user. Rosemount standard (default), NAMUR, and custom alarm levels are available (see Table 3). High or low alarm signal is software-selectable or hardware-selectable via the optional switch (option D1). (1) Static pressure selection may effect pressure limitations. 6

4 , Rev EA The Annubar Flowmeter Series TABLE 3. Alarm Configuration High Alarm Low Alarm Default ma 3.75 ma NAMUR compliant (1) 22.5 ma 3.6 ma (2) (3) Custom levels ma ma (1) Analog output levels are compliant with NAMUR recommendation NE 3, see option codes C or C5. (2) Low alarm must be 0.1 ma less than low saturation and high alarm must be 0.1 ma greater than high saturation. (3) Not available with the 3051S SIS Safety Transmitter. 3051S SIS Safety Transmitter Failure Values Safety accuracy: 2.0% (1) Safety response time: 1.5 seconds (1) A 2% variation of the transmitter ma output is allowed before a safety trip. Trip values in the DCS or safety logic solver should be derated by 2%. Dynamic Performance Total Response Time (Td + Tc) (3) : 3051S_C, Ranges 2A - 3A: Range 1A: - 20 ma (HART ) (1) Fieldbus protocol (2) Typical Transmitter Response Time 100 milliseconds 255 milliseconds 152 milliseconds 307 milliseconds Transmitter Output vs. Time Process Variable Response Time 3051S SIS, Ranges 2A - 3A: Range 1A: 220 milliseconds 375 milliseconds Not Applicable Not Applicable Dead Time (Td) () 5 milliseconds (nominal) 97 milliseconds Update Rate 3051S 3051S SIS 22 times per second 11 times per second 22 times per second Not Applicable Pressure Released T d 100% 36.8% 0% T c Time T d = Dead Time T c = Time Constant Response Time = T d +T c 63.2% of Total Step Change _17A (1) Dead time and update rate apply to all models and ranges; analog output only (2) Transmitter fieldbus output only, segment macro-cycle not included. (3) Nominal total response time at 75 F (2 C) reference conditions. For option code DA1, add 0 milliseconds (nominal) to -20 ma (HART ) total response time values. () For option code DA1, dead time (Td) is 85 milliseconds (nominal). 7

5 , Rev EA Straight Run Requirements Flowmeter Orientation Upstream Dimensions Gas (Horizontal) Without Vanes (1) In Plane A With Vanes (2) Out of Plane A A C C Downstream Recommended Zone 120 degrees 30 degrees 30 degrees 8 2 Liquid and Steam (Horizontal) degrees 30 degrees degrees Recommended Zone Gas (Vertical) Flow degrees Steam (Vertical) degrees Flow (1) In Plane A means the bar is in the same plane as the elbow. Out of Plane A means the bar is perpendicular to the plane of the elbow. (2) Use straightening vane to reduce the required straight run length. Drill Hole Size According to Sensor Size Sensor Size Diameter 1 3 /-in. (19 mm) /16-in. (3 mm) /2-in. (6 mm) 8

6 , Rev EA The Annubar Flowmeter Series Physical Temperature Measurement Integral RTD 100 Ohm platinum RTD -wire RTD ( = ) Remote RTD 100 Ohm platinum RTD, spring loaded with 1 /2-in. NPT nipple and union (078 series with Rosemount 6 housing) Thermowell with Remote RTD 1 /2-in. x 1 /2-in NPT, 316 Stainless Steel with 1 /2-in. weld couplet to match pipe material Electronic Connections 1 /2 1 NPT, G 1 /2, and M (CM20) conduit. HART interface connections fixed to terminal block for output code A Annubar Sensor Material 316 Stainless Steel Hastelloy 276 Annubar Type See Dimensional Drawings on page 1 Pak-Lok Model (option P) Provided with a compression sealing mechanism rated up to 600# ANSI (10 psig at 100 F (99 bar at 38 C)) Graphite Packing ( 300 to 850 F ( 18 to 5 C)) Flanged with Opposite Side Support Model (option F) Provided with opposite side support, which is the same material as the pipe and requires a second pipe penetration Sensor flange is the same material as the Annubar sensor and the mounting flange is the same material as the pipe material Flanged mounting hardware: nuts, bolts and gaskets (constructed from the same material as the pipe material) SST: ( 300 to 850 F ( 18 to 5 C)) Hastelloy: ( 300 to 1250 F ( 18 to 677 C)) Flange Lok Model (option L) Flange Lok assembly is supplied in 316 SST material. Flange-Lok mounting hardware: nuts, bolts and gaskets (constructed from the same material as the pipe material) 300 to 850 F ( 18 to 5 C) Flo-Tap Models (options G and M) Opposite side support is not available Threaded connection is not available with Sensor Size 3 Gear Drive is not available with Sensor Size 1 Packing gland required Packing Gland Material Temperature Limits Teflon (PTFE): 0 to 00 F ( 0 to 20 C) Graphite: 300 to 850 F ( 18 to 5 C) Isolation valve included The isolation valve will carry the same pressure rating as the sensor flange and mounting flange specified in the mounting type Ball valves have a 300# limitation For threaded flo-tap models, the isolation valve NPT size is 1 1 /-in. (Sensor Size one) and 2-in. (Sensor Size 2). Annubar Type Specification Chart Option Description Pak-Lok (1) Flange-Lok Flange (1) Available up to 600# ANSI (10 psig at 100 F (99 bar at 38 C)) rating. Instrument Connections Temperature Ranges TABLE. Minimum / Maximum Temperature Range Manual and Gear Drive Flo-Tap T1 (1) Pak-Lok Body X Threaded connection X A1 150# RF ANSI X X X A3 300# RF ANSI X X X A6 600# RF ANSI X X X A9 (2) 900# RF ANSI X AF (2) 1500# RF ANSI X AT (2) 2500# RF ANSI X D1 DN PN 16 X X X D3 DN PN 0 X X X D6 DN PN 100 X X X R9 (2) 900# RTJ Flange X RF (2) 1500# RTJ Flange X RT (2) 2500# RTJ Flange X (2) Remote mount only. Description Temperature G1 Needle Valves, Carbon Steel 20 to 500 F ( 29 to 260 C) G2 Needle Valves, Stainless Steel 0 to 600 F ( 0 to 316 C) G3 Needle Valves, Hastelloy 0 to 600 F ( 0 to 316 C) G5 OS&Y Gate Valve, Carbon Steel 20 to 775 F ( 29 to 13 C) G6 OS&Y Gate Valve, Stainless Steel 0 to 850 F ( 0 to 5 C) G7 OS&Y Gate Valve, Hastelloy 0 to 1250 F ( 0 to 677 C) 9

7 , Rev EA Flowmeter Installed in Flanged Pipe Spool Section (option codes H3, H, and H5) All pipe spool sections are flanged pipe sections The flanged pipe spool section is constructed from the same material as the pipe Consult the factory for remote temperature measurement and ANSI ratings above 600# and DIN flanges TABLE 5. Flanged Pipe Spool Section Schedule ANSI 150# ANSI 0 300# ANSI 0 600# ANSI 80 Schedule TABLE 6. Flange Pipe Spool Section Length Nominal Pipe Size 2-in. (50 mm) 3-in. (80 mm) -in. (100 mm) 6-in. (150 mm) 8-in. (200 mm) Length in. (267.2 mm) in. (288.8 mm) 12.7-in. (323.6 mm) 1.33-in. (36.0 mm) in. (21.1 mm) Process-Wetted Parts Integral Manifolds 316 SST Hastelloy C-276 Remote Manifolds 316 SST Hastelloy C-276 Transmitter Vent Valves and Process Flanges 316 SST Hastelloy C-276 Process Isolating Diaphragms 316L SST Hastelloy C-276 O-rings Glass-filled TFE Integral Manifold O-Rings Teflon (PTFE) / Graphite Non-Wetted Parts Sensor Module Fill Fluid Silicone oil Inert Fill optional Cover O-rings Buna-N Remote Mounting Brackets SST Sensor mounting (including nuts, bolts, and gasket) Match Process Pipe material Electronic Housing Low copper aluminum, NEMA x, IP65 SST (optional) Paint Polyurethane Bolts CS 10

8 , Rev EA The Annubar Flowmeter Series PRODUCT CERTIFICATIONS Approved Manufacturing Locations Rosemount Inc. Chanhassen, Minnesota USA Emerson Process Management GmbH & Co. Wessling, Germany Emerson Process Management Asia Pacific Private Limited Singapore Beijing Rosemount Far East Instrument Co., LTD Beijing, China European Directive Information The EC declaration of conformity for all applicable European directives for this product can be found at A hard copy may be obtained by contacting an Emerson Process Management representative. ATEX Directive (9/9/EC) Emerson Process Management complies with the ATEX Directive. European Pressure Equipment Directive (PED) (97/23/EC) Models 3051S_CA; 3051S_CD2, 3,, 5; (also with P9 option) Pressure Transmitters QS Certificate of Assessment - EC No. PED-H-20, Module H Conformity Assessment All other Model 3051S Pressure Transmitters Sound Engineering Practice Transmitter Attachments: Diaphragm Seal - Process Flange - Manifold Sound Engineering Practice Primary Elements, Flowmeter See appropriate Primary Element QIG Electro Magnetic Compatibility (EMC) (89/336/EEC) All Models: EN : 1992; EN :1995; EN :1997 Industrial Ordinary Location Certification for FM As standard, the transmitter has been examined and tested to determine that the design meets basic electrical, mechanical, and fire protection requirements by FM, a nationally recognized testing laboratory (NRTL) as accredited by the Federal Occupational Safety and Health Administration (OSHA). Hazardous Locations Certifications North American Certifications FM Approvals E5 Explosion-proof for Class I, Division 1, Groups B, C, and D; dust-ignition proof for Class II and Class III, Division 1, Groups E, F, and G; hazardous locations; enclosure Type X, conduit seal not required when installed according to Rosemount drawing I5/IE Intrinsically Safe for use in Class I, Division 1, Groups A, B, C, and D; Class II, Division 1, Groups E, F, and G; Class III, Division 1; Class I, Zone 0 AEx ia IIC when connected in accordance with Rosemount drawing ; Non-incendive for Class I, Division 2, Groups A, B, C, and D Enclosure Type X For entity parameters see control drawing Canadian Standards Association (CSA) E6 Explosion-proof for Class I, Division 1, Groups B, C, and D; Dust-Ignition-Proof for Class II and Class III, Division 1, Groups E, F, and G; suitable for Class I, Division 2, Groups A, B, C, and D, when installed per Rosemount drawing , CSA Enclosure Type X; conduit seal not required. I6/IF Intrinsically Safe for Class I, Division 1, Groups A, B, C, and D when connected in accordance with Rosemount drawings ; For entity parameters see control drawing European Certifications I1/IA ATEX Intrinsic Safety Certificate No.: BAS01ATEX1303X EEx ia IIC T5 (-60 C T a 0 C) T (-60 C T a 70 C) T (-60 C T a 0 C) (FISCO) 1180 TABLE 7. Input Parameters Loop / Power U i = 30 V U i = 17.5 V I i = 300 ma I i = 380 ma P i = 1.0 W P i = 1.3 W P i = 5.32 W C i = 30 nf C i = 11. nf C i = 0 L i = 0 L i = 60 µh II 1G Groups HART / FOUNDATION fieldbus/ Remote Display / SIS FISCO HART / FOUNDATION fieldbus/ Remote Display / SIS FISCO HART / Remote Display / SIS FOUNDATION fieldbus FISCO SuperModule Platform HART / SIS FOUNDATION fieldbus / Remote Display / FISCO HART / FOUNDATION fieldbus/ SIS / FISCO Remote Display Special conditions for safe use (x) 1. The apparatus, excluding the Types 3051 S-T and 3051 S-C (In-line and Coplanar SuperModules respectively), is not capable of withstanding the 500V test as defined in Clause of EN This must be considered during installation. 2. The terminal pins of the Types 3051 S-T and 3051 S-C must be protected to IP20 minimum. 11

9 , Rev EA N1 ND E1 ATEX Type n Certificate No.: BAS01ATEX330X II 3 G EEx nl IIC T5 (T a = -0 C TO 70 C) Ui = 5 Vdc max IP66 Special conditions for safe use (x) The apparatus is not capable of withstanding the 500V insulation test required by Clause 9.1 of EN 50021: This must be taken into account when installing the apparatus. ATEX Dust Certificate No.: BAS01ATEX137X II 1 D T105 C (-20 C T amb 85 C) V max = 2. volts max A = 2 ma IP Special conditions for safe use (x) 1. The user must ensure that the maximum rated voltage and current (2. volts, 22 milliampere, DC) are not exceeded. All connections to other apparatus or associated apparatus shall have control over this voltage and current equivalent to a category ib circuit according to EN Cable entries must be used which maintain the ingress protection of the enclosure to at least IP Unused cable entries must be filled with suitable blanking plugs which maintain the ingress protection of the enclosure to at least IP66.. Cable entries and blanking plugs must be suitable for the ambient range of the apparatus and capable of withstanding a 7J impact test. 5. The 3051S must be securely screwed in place to maintain the ingress protection of the enclosure. ATEX Flameproof Certificate No.: KEMA00ATEX213X II 1/2 G EEx d IIC T6 (-50 C T amb 65 C) EEx d IIC T5 (-50 C T amb 80 C) V max = 2.V 1180 Special conditions for safe use (x) This device contains a thin wall diaphragm. Installation, maintenance and use shall take into account the environmental conditions to which the diaphragm will be subjected. The manufacturer s instructions for installation and maintenance shall be followed in detail to assure safety during its expected lifetime. The Model 3051S pressure transmitter must include a Series 300S housing integrally mounted to a Series Model 3051S Sensor module as per Rosemount drawing Japanese Certifications E JIS Flameproof Ex d IIC T6 Australian Certifications E7 Certificate TC15682 TC15683 TC1568 TC15685 TC15686 TC15687 TC15688 TC15689 TC15690 Description Coplanar with Junction Box Housing Coplanar with PlantWeb Housing Coplanar with PlantWeb Housing and LCD Display In-Line SST with Junction Box Housing In-Line Hastelloy with Junction Box Housing In-Line SST with PlantWeb Housing In-Line Hastelloy with Plantweb Housing In-Line SST with Plantweb Housing and LCD Display In-Line Hastelloy with PlantWeb Housing and LCD Display SAA Explosion-proof and DIP Certification No.: AUS Ex 3798X Ex d IIC T6 (T a = 60 C) IP66 DIP A21 TA T6 (T a = 60 C) IP66 Special conditions for safe use (x) 1. It is a condition of manufacture that each transmitter module shall be pressure tested in accordance with clause.3 of AS at minimum pressure of 150 kpa. As the model 300S housing passed tests at times the reference pressures (00 kpa for single and 3800 kpa for dual compartment housing) and are not of welded construction, they may be exempted from the routing pressure test of clause.3 of AS It is a condition of manufacture that each transmitter module and housing combination shall be subjected to a routine high voltage test in accordance with clause 6.2 of AS , with the following variation. The test voltage applied to each single or dual compartment housing shall not be less than 500 V, 7 to 62 Hz, for a period of not less than one minute, with a breakdown current of less than 5 ma. 3. It is a condition of safe use that each housing shall be connected to external circuits via suitable conduit or Standards Australia certified cable glands. Where only one entry is used for connection to external circuits, the unused entry shall be closed by means of the blanking plug supplied by the equipment manufacturer or by a suitable Standards Australia certified blanking plug.. It is a condition of safe use that a dielectric strength test shall be applied whenever the terminal block is changed or replaced in either the dual compartment or single compartment housings. The breakdown current shall be less than 5 ma, when 500 V, 7 to 62 Hz, is applied for one minute. Note: if tested with an optional T1 transient protector terminal block fitted, the protection will operate and hence there will be no current indicated. 5. It is a condition of safe use that each transmitter module shall be used with a Model 300S housing, in order to comply with flameproof requirements. 12

10 , Rev EA The Annubar Flowmeter Series 6. It is a condition of safe use that each model 300S housing fitted with a transmitter module shall be marked with the same certification marking code information. Should the housing be replaced after initial supply to another model 300S housing, the replacement housing shall have the same certification marking code information as the housing it replaces. IECEx Certifications I7/IG IECEx Intrinsic Safety Certificate No.: IECExBAS0.0017X Ex ia IIC T5 (T a = -60 C to 0 C) -HART/SIS/Remote Meter Ex ia IIC T (T a = -60 C to 70 C) -HART/SIS/Remote Meter Ex ia IIC T (T a = -60 C to 70 C) -FOUNDATION Fieldbus Ex ia IIC T (T a = -60 C to 0 C) -FISCO IP66 TABLE 8. Input Parameters Loop / Power U i = 30 V U i = 17.5 V I i = 300 ma I i = 380 ma P i = 1.0 W P i = 1.3 W P i = 5.32 W C i = 30 nf C i = 11. nf C i = 0 L i = 0 Groups HART / FOUNDATION fieldbus/ Remote Display / SIS FISCO HART / FOUNDATION fieldbus/ Remote Display / SIS FISCO HART / Remote Display / SIS FOUNDATION fieldbus FISCO SuperModule Platform HART / SIS FOUNDATION fieldbus / Remote Display / FISCO HART / FOUNDATION fieldbus/ SIS / FISCO N7 IECEx Type n Certificate No.: IECExBAS0.0018X Ex nc IIC T5 (Ta = -0 C to 70 C) Ui = 5 Vdc MAX IP66 Special conditions for safe use (x) The apparatus is not capable of withstanding the 500 V insulation test required by Clause 8 of IEC 79-15: Combinations of Certifications Stainless steel certification tag is provided when optional approval is specified. Once a device labeled with multiple approval types is installed, it should not be reinstalled using any other approval types. Permanently mark the approval label to distinguish it from unused approval types. K1 Combination of E1, I1, N1, and ND K5 Combination of E5 and I5 K6 Combination of E6 and I6 K7 Combination of E7, I7, and N7 KA Combination of E1, I1, E6, and I6 KB Combination of E5, I5, I6 and E6 KC Combination of E5, E1, I5 and I1 KD Combination of E5, I5, E6, I6, E1, and I1 Special conditions for safe use (x) 1.The Models 3051S HART -20mA, 3051S Fieldbus, 3051S Profibus and 3051S FISCO are not capable of withstanding the 500V test as defined in clause of IEC This must be taken into account during installation. 2.The terminal pins of the Types 3051S-T and 3051S-C must be protected to IP20 minimum. 13

11 , Rev EA DIMENSIONAL DRAWINGS Pak-Lok ProBar Flowmeter (1) Front View Side View Top View D B C A (1) The Pak-Lok Annubar model is available up to 600# ANSI (10 psig at 100 F (99 bar at 38 C)). TABLE 9. Pak-Lok ProBar Flowmeter Dimensional Data Sensor Size A (Max) B (Max) C (Max) D (Max) (190.5) (07.2) 9.00 (228.6) 6.90 (175.3) (235.0) (51.6) 9.00 (228.6) 6.90 (175.3) (30.8) (508.8) 9.00 (228.6) 6.90 (175.3) Dimensions are in inches (millimeters) 1

12 , Rev EA The Annubar Flowmeter Series Flange-Lok ProBar Flowmeter (1) Front View Side View Top View E C D B A (1) The Flange-Lok Annubar model can be direct mounted up to 600# ANSI (10 psig at 100 F (99 bar at 38 C)). TABLE 10. Flange-Lok ProBar Flowmeter Dimensional Data Sensor Size Flange Size and Rating A ± (3.2) B ± 0.25 (6.) C (Max) D (Max) E (Max) /2 150# 3.88 (98.6) (311.2) (527.8) 9.00 (228.6) (285.8) /2 300#.13 (10.9) (311.2) (527.8) 9.00 (228.6) (285.8) /2 600#. (112.8) (311.2) (527.8) 9.00 (228.6) (285.8) 1 DN0/PN (78.5) (311.2) (527.8) 9.00 (228.6) (285.8) 1 DN0/PN (81.5) (311.2) (527.8) 9.00 (228.6) (285.8) 1 DN0/ PN (98.6) (311.2) (527.8) 9.00 (228.6) (285.8) #.13 (10.9) 1.25 (362.0) (578.6) 9.00 (228.6) (285.8) #.38 (111.3) 1.25 (362.0) (578.6) 9.00 (228.6) (285.8) #.76 (120.9) 1.25 (362.0) (578.6) 9.00 (228.6) (285.8) 2 DN50/PN (86.) 1.25 (362.0) (578.6) 9.00 (228.6) (285.8) 2 DN50/PN (89.2) 1.25 (362.0) (578.6) 9.00 (228.6) (285.8) 2 DN50/ PN (109.2) 1.25 (362.0) (578.6) 9.00 (228.6) (285.8) #.63 (117.6) (.5) (661.2) 9.00 (228.6) (285.8) # 5.00 (127.0) (.5) (661.2) 9.00 (228.6) (285.8) # 5.38 (136.7) (.5) (661.2) 9.00 (228.6) (285.8) 3 DN80/PN (97.5) (.5) (661.2) 9.00 (228.6) (285.8) 3 DN80/PN0.16 (105.7) (.5) (661.2) 9.00 (228.6) (285.8) 3 DN80/ PN (125.7) (.5) (661.2) 9.00 (228.6) (285.8) Dimensions are in inches (millimeters) 15

13 , Rev EA Flanged ProBar Flowmeter Front View Side View Top View E B C D A F TABLE 11. Flanged ProBar Flowmeter Dimensional Data Flange Size and A ± B ± 0.25 C ± 0.25 Sensor Size Rating (3.2) (6.) (6.) D (Max) E (Max) F (Max) /2 150# 3.88 (98.6) (279.) (96.1) 9.00 (228.6) 6.30 (160.0) 3.50 (88.9) /2 300#.13 (10.9) (279.) (96.1) 9.00 (228.6) 6.86 (17.2) 3.50 (88.9) /2 600#. (112.8) (279.) (96.1) 9.00(228.6) 6.86 (17.2) 3.50 (88.9) 1 DN0/PN (78.5) (279.) (96.1) 9.00 (228.6) 6.86 (17.2) 3.50 (88.9) 1 DN0/PN (81.5) (279.) (96.1) 9.00 (228.6) 6.86 (17.2) 3.50 (88.9) 1 DN0/ PN (98.6) (279.) (96.1) 9.00(228.6) 6.86 (17.2) 3.50 (88.9) /2 900#.9 (125.5) 9.32 (236.6) 3.50 (88.9) /2 1500#.9 (125.5) 9.32 (236.6) 3.50 (88.9) /2 2500# 6.76 (171.7) 11.6 (295.5).00 (101.6) #.13 (10.9) (30.8) (521.5) 9.00 (228.6) 6.80 (172.7) 5.00 (127.0) #.38 (111.3) (30.8) (521.5) 9.00 (228.6) 7.05 (179.1) 5.00 (127.0) #.76 (120.9) (30.8) (521.5) 9.00 (228.6) 7.05 (179.1) 5.00 (127.0) 2 DN50/PN (86.) (30.8) (521.5) 9.00 (228.6) 7.05 (179.1) 5.00 (127.0) 2 DN50/PN (89.2) (30.8) (521.5) 9.00 (228.6) 7.05 (179.1) 5.00 (127.0) 2 DN50/ PN (109.2) (30.8) (521.5) 9.00 (228.6) 7.05 (179.1) 5.00 (127.0) # 5.88 (19.) (266.8) 5.00 (127.0) # 5.88 (19.) (266.8) 5.00 (127.0) # 9.87 (250.7) (396.7).50 (11.3) #.63 (117.6) (32.9) (559.6) 9.00 (228.6) 7.55 (191.8).00 (101.6) # 5.00 (127.0) (32.9) (559.6) 9.00 (228.6) 7.93 (201.3).00 (101.6) Table 11 Continued on Next Page 16

14 , Rev EA The Annubar Flowmeter Series TABLE 11. Flanged ProBar Flowmeter Dimensional Data Flange Size and A ± B ± 0.25 C ± 0.25 Sensor Size Rating (3.2) (6.) (6.) D (Max) E (Max) F (Max) # 5.38 (136.7) (32.9) (559.6) 9.00 (228.6) 7.93 (201.3).00 (101.6) 3 DN80/PN (97.5) (32.9) (559.6) 9.00 (228.6) 7.93 (201.3).00 (101.6) 3 DN80/PN0.16 (105.7) (32.9) (559.6) 9.00 (228.6) 7.93 (201.3).00 (101.6) 3 DN80/ PN (125.7) (32.9) (559.6) 9.00 (228.6) 7.93 (201.3).00 (101.6) 3 900# 8.19 (208.0) 13. (31.3) 7.00 (177.8) # 8.56 (217.) (350.8) 7.00 (177.8) # (28.2) (39.8) 7.00 (177.8) Dimensions are in inches (millimeters) 17

15 , Rev EA Flanged Flo-Tap ProBar Flowmeter (1) Front View Side View Top View F D E C B A (1) The Flanged Flo-Tap ProBar Flowmeter is available with both the manual and gear drive options. TABLE 12. Flanged Flo-Tap ProBar Flowmeter Dimensional Data Sensor Size Flange Size and Rating A ± (3.2) B ± 0.25 (6.) Note: Customer Supplied. Inserted, C Dimension = Pipe I.D. + Wall Thickness + B + C I Retracted, C Dimension = 2 x (Pipe I.D. + Wall Thickness + B) + C I C I (Max) (Gear Drive) C I (Max) (Manual) D (Max) E (Max) F (Max) /2 150# 3.88 (98.5) (266.7) 17.9 (5.7) C (216.7) (266.7) (285.8) /2 300#.13 (10.9) (298.5) 17.9 (5.7) C (216.7) (266.7) (285.8) /2 600#. (112.8) 1.06 (357.2) 17.9 (5.7) C (216.7) (266.7) (285.8) 1 DN0/PN (78.5) See Note (5.7) C (216.7) (266.7) (285.8) 1 DN0/PN (81.5) See Note (5.7) C (216.7) (266.7) (285.8) 1 DN0/PN (98.6) See Note (5.7) C (216.7) (266.7) (285.8) #.13 (10.9) (285.8) 2.6 (62.8) 21. (53.6) C (216.7) (319.0) (285.8) #.38 (111.3) (330.2) 2.6 (62.8) 21. (53.6) C (216.7) (319.0) (285.8) #.76 (120.9) (16.0) 2.6 (62.8) 21. (53.6) C (216.7) (319.0) (285.8) 2 DN50/PN (86.) See Note. 2.6 (62.8) 21. (53.6) C (216.7) (319.0) (285.8) 2 DN50/PN (89.2) See Note. 2.6 (62.8) 21. (53.6) C (216.7) (319.0) (285.8) 2 DN50/PN (109.2) See Note. 2.6 (62.8) 21. (53.6) C (216.7) (319.0) (285.8) #.63 (117.6) (323.9) 26.5 (673.1) 23.3 (591.8) C (216.7) 1.13 (358.9) (285.8) # 5.00 (127.0) (12.8) 26.5 (673.1) 23.3 (591.8) C (216.7) 1.13 (358.9) (285.8) # 5.38 (136.7) (95.) 26.5 (673.1) 23.3 (591.8) C (216.7) 1.13 (358.9) (285.8) 3 DN80/PN (97.5) See Note (673.1) 23.3 (591.8) C (216.7) 1.13 (358.9) (285.8) 3 DN80/PN0.16 (105.7) See Note (673.1) 23.3 (591.8) C (216.7) 1.13 (358.9) (285.8) 3 DN80/PN (125.7) See Note (673.1) 23.3 (591.8) C (216.7) 1.13 (358.9) (285.8) Dimensions are in inches (millimeters) 18

16 , Rev EA The Annubar Flowmeter Series Threaded Flo-Tap ProBar Flowmeter (1) Front View Side View Top View E C D B A (1) The Flanged Flo-Tap ProBar Flowmeter is available with both the manual and gear drive options. TABLE 13. Threaded Flo-Tap ProBar Flowmeter Dimensional Data Sensor Size A ± 0.50 (12.7) B I (Max) (Gear Drive) B I (Max) (Manual) C (Max) D (Max) E (Max) (171.8) 17.0 (2.0) B (216.7) (266.7) 6.90 (175.3) (207.5) (602.0) (528.3) B (216.7) (319.0) 6.90 (175.3) Sensor Size 3 is not available in a Threaded Flo-Tap. Dimensions are in inches (millimeters) Inserted, B Dimension = Pipe I.D. + Wall Thickness + A + B I Retracted, B Dimension = 2 x (Pipe I.D. + Wall Thickness + A) + B I 19

17 , Rev EA ORDERING INFORMATION Rosemount 3051SFA ProBar Flowmeter Ordering Information Model 3051SFA D L G S Product Description ProBar Flowmeter Measurement Type Differential Pressure Fluid Type Liquid Gas Steam Line Size Line Size in. (50 mm) in. (50 mm) /2-in. (63.5 mm) in. (500 mm) in. (80 mm) 20 2-in. (600 mm) /2-in. (89 mm) in. (750 mm) 00 -in. (100 mm) in. (900 mm) in. (125 mm) 20 2-in. (1066 mm) in. (150 mm) 80 8-in. (1210 mm) in. (175 mm) in. (1520 mm) in. (200 mm) in. (1820 mm) in. (250 mm) in (1950 mm) in. (300 mm) 80 8-in. (2100 mm) 10 1-in. (350 mm) in. (2250 mm) in. (00 mm) in (200 mm) Pipe I.D. Range (Refer to the Pipe I.D. Range measured in inches (millimeters) on page 26) A Range A from the Pipe I.D. table B Range B from the Pipe I.D. table C Range C from the Pipe I.D. table D Range D from the Pipe I.D. table E Range E from the Pipe I.D. table Z Non-standard Pipe I.D. Range or Line Sizes greater than 12 inches Pipe Material / Mounting Assembly Material C Carbon steel S 316 Stainless Steel G Chrome-Moly Grade F-11 N Chrome-Moly Grade F-22 J Chrome-Moly Grade F-91 0 (1) No Mounting (Customer Supplied) H D U P F L G M Piping Orientation Horizontal Piping Vertical Piping with Downwards Flow Vertical Piping with Upwards Flow Annubar Type Pak-Lok Flanged with opposite side support Flange-Lok Gear-Drive Flo-Tap Manual Flo-Tap Sensor Material S 316 Stainless Steel H Hastelloy C

18 , Rev EA The Annubar Flowmeter Series Rosemount 3051SFA ProBar Flowmeter Ordering Information Sensor Size 1 Sensor size 1 Line sizes 2-in. (50 mm) to 8-in. (200 mm) 2 Sensor size 2 Line sizes 6-in. (150 mm) to 96-in. (200 mm) 3 Sensor size 3 Line sizes greater than 12-in. (300 mm) Mounting Type T1 Compression or Threaded Connection A1 150# RF ANSI A3 300# RF ANSI A6 600# RF ANSI A9 (2) 900# RF ANSI AF (2) 1500# RF ANSI AT (2) 2500 # RF ANSI D1 DN PN16 Flange D3 DN PN0 Flange D6 DN PN100 Flange R9 (2) 900# RTJ Flange RF (2) 1500# RTJ Flange RT (2) 2500# RTJ Flange Opposite Side Support and Packing Gland 0 No opposite side support or packing gland (Required for Pak-Lok and Flange-Lok models) Opposite Side Support Required for Flanged Models C NPT Threaded Opposite Support Assembly Extended Tip D Welded Opposite Support Assembly Extended Tip Packing Gland Required for Flo-Tap Models Packing Gland Material Rod Material Packing Material J Stainless Steel Packing Gland / Cage Nipple Carbon Steel Teflon K Stainless Steel Packing Gland / Cage Nipple Stainless Steel Teflon L Stainless Steel Packing Gland / Cage Nipple Carbon Steel Graphite N Stainless Steel Packing Gland / Cage Nipple Stainless Steel Graphite R Hastelloy Packing Gland / Cage Nipple Stainless Steel Graphite Isolation Valve for Flo-Tap Models 1 Gate Valve, Carbon Steel 2 Gate Valve, Stainless Steel 5 Ball Valve, Carbon Steel 6 Ball Valve, Stainless Steel 0 (1) Not Applicable or Customer Supplied Temperature Measurement T Integral RTD not available with Flanged model greater than class 600 R Remote Thermowell and RTD 0 No Temperature Sensor Electronics Connection Platform 3 Direct-mount, Integral 3-valve manifold not available with Flanged model greater than class Direct -mount, 5-valve manifold not available with Flanged model greater than class Direct-mount, high temperature 5-valve manifold not available with Flanged model greater than class Remote-mount NPT Connections 8 Remote-mount SW Connections 1A 2A 3A Differential Pressure Ranges 0 to 25 in H 2 O (0 to 62.2 mbar) 0 to 250 in H 2 O (0 to 623 mbar) 0 to 1000 in H 2 O (0 to 2.5 bar) 21

19 , Rev EA Rosemount 3051SFA ProBar Flowmeter Ordering Information Output Protocol A 20 ma with digital signal based on HART protocol B (3) 20 ma Safety Certified with digital signal based on HART protocol F () FOUNDATION fieldbus protocol Electronics Housing Style Material Conduit Entry Size 1A PlantWeb Housing Aluminum 1 /2-1 NPT 1B PlantWeb Housing Aluminum M20 x 1.5 (CM20) 1C PlantWeb Housing Aluminum G 1 /2 1J PlantWeb Housing 316L SST 1 /2-1 NPT 1K PlantWeb Housing 316L SST M20 x 1.5 (CM20) 1L PlantWeb Housing 316L SST G 1 /2 2A Junction Box Housing Aluminum 1 /2-1 NPT 2B Junction Box Housing Aluminum M20 x 1.5 (CM20) 2C Junction Box Housing Aluminum G 1 /2 2E Junction Box housing with output for remote display and interface Aluminum 1 /2-1 NPT 2F Junction Box housing with output for remote display and interface Aluminum M20 x 1.5 (CM20) 2G Junction Box housing with output for remote display and interface Aluminum G 1 /2 2J Junction Box Housing 316L SST 1 /2-1 NPT 2M Junction Box housing with output for remote display and interface 316L SST 1 /2-1 NPT 7J (5) Quick Connect (A size Mini, -pin male termination) 316L SST Electronics Performance Class 3 (6) Ultra for Flow: up to 0.8% flow rate accuracy, 10:1 flow turndown, 10-year stability. limited 12-year warranty 1 (6) Ultra: up to 0.9% flow rate accuracy, 8:1 flow turndown, 10-year stability, limited 12-year warranty 2 Classic: up to 1.1% flow rate accuracy, 8:1 flow turndown, 5-year stability Options Pressure Testing P1 (7) Hydrostatic Testing with Certificate PX (7) Extended Hydrostatic Testing Special Cleaning P2 Cleaning for Special Processes PA Cleaning per ASTM G93 level D (section 11.) Material Testing V1 Dye Penetrant Exam Material Examination V2 Radiographic Examination Flow Calibration W1 Flow Calibration (Average K) WZ Special Calibration Special Inspection QC1 Visual and Dimensional Inspection with Certificate QC7 Inspection and Performance Certificate Surface Finish RL Surface finish for Low Pipe Reynolds Number in Gas and Steam RH Surface finish for High Pipe Reynolds Number in Liquid Material Traceability Certification Q8 (8) Material Certificate per ISO B and EN B 22

20 , Rev EA The Annubar Flowmeter Series Rosemount 3051SFA ProBar Flowmeter Ordering Information Conformance J1 Canadian Registration J2 (9) ANSI B31.1 J3 (9) ANSI B31.3 J (9) ANSI B31.8 J5 (10) NACE MR-0175 / ISO J6 European Pressure Directive (PED) Installed in Flanged Pipe Spool Section H3 150# Flanged Connection with Rosemount Standard Length and Schedule H 300# Flanged Connection with Rosemount Standard Length and Schedule H5 600# Flanged Connection with Rosemount Standard Length and Schedule Instrument Connections for Remote Mount Option G1 Needle Valves, Carbon Steel G2 Needle Valves, Stainless Steel G3 Needle Valves, Hastelloy G5 OS&Y Gate Valve, Carbon Steel G6 OS&Y Gate Valve, Stainless Steel G7 OS&Y Gate Valve, Hastelloy Special Shipment Y1 Mounting Hardware Shipped Separately Special Dimensions VM Variable Mounting VT Variable Tip VS Variable length Spool Section V9 Special Dimension Transmitter Calibration Certification Q Calibration Data Certificate for Transmitter QP Calibration Data Certificate and Tamper Evident Seal Safety Certification QS Certificate of FMEDA data Product Certifications E1 ATEX Flameproof I1 ATEX Intrinsically Safe N1 ATEX Type n IA (11) ATEX FISCO Intrinsically Safe; for FOUNDATION fieldbus protocol only K1 ATEX Flameproof, Intrinsically Safe, Type n, and Dust (combination of E1, I1, N1, and ND) ND ATEX Dust E5 FM Explosion-proof I5 FM Intrinsically Safe, Non-incendive IE (11) FM FISCO Intrinsically Safe; for FOUNDATION fieldbus protocol only K5 FM Explosion-proof, Intrinsically Safe, Non-incendive (combination of E5 and I5) E6 CSA Explosion-proof, Division 2 I6 CSA Intrinsically Safe IF (11) CSA FISCO Intrinsically Safe; for FOUNDATION fieldbus protocol only K6 CSA Explosion-proof, Intrinsically Safe, Division 2 (combination of E6 and I6) E7 (11) SAA Flameproof, Dust Ignition-proof I7 IECEx Intrinsically Safe IG (11) IECEx FISCO Intrinsically Safe N7 IECEx Type n K7 SAA Flameproof, Dust Ignition-proof, IECEx Intrinsically Safe, and Type n (combination of E7, I7, and N7) KA ATEX and CSA Flameproof, Intrinsically Safe (combination of E1, I1, E6, and I6) Note: Only available on Housing Style codes IA, IJ, 2A, 2J, 2E, or 2M. KB FM and CSA Explosion-proof, Intrinsically Safe, Division 2 (combination of E5, E6, I5, and I6) Note: Only available on Housing Style codes IA, IJ, 2A, 2J, 2E, or 2M. KC FM and ATEX Explosion-proof, Intrinsically Safe, Non-incendive (combination of E5, E1, I5, and I1) Note: Only available on Housing Style codes IA, IJ, 2A, 2J, 2E, or 2M. KD FM, CSA, and ATEX Explosion-proof, Intrinsically Safe (combination of E5, I5, E6, I6, E1, and I1) Note: Only available on Housing Style codes IA, IJ, 2A, 2J, 2E, or 2M. 23

21 , Rev EA Rosemount 3051SFA ProBar Flowmeter Ordering Information Alternate Transmitter Materials of Construction L1 Inert Sensor Fill Fluid L2 Graphite-Filled Teflon (PTFE) O-Ring LA Inert Sensor Fill Fluid and Graphite-Filled Teflon (PTFE) O-ring Display (12) M5 PlantWeb LCD display M7 (6)(13) Remote mount LCD display and interface, PlantWeb housing, no cable, SST bracket M8 (6)(13) Remote mount LCD display and interface, PlantWeb housing, 50 foot cable, SST bracket M9 (6)(13) Remote mount LCD display and interface, PlantWeb housing, 100 foot cable, SST bracket Terminal Blocks T1 (12) Transient terminal block T2 (1) Terminal block with WAGO spring clamp terminals T3 (1) Transient terminal block with WAGO spring clamp terminals Manifold for Remote Mount Option F1 3-Valve Manifold, Carbon Steel F2 3-Valve Manifold, Stainless Steel F3 3-Valve Manifold, Hastelloy C F5 5-Valve Manifold, Carbon Steel F6 5-Valve Manifold, Stainless Steel F7 5-Valve Manifold, Hastelloy C PlantWeb Control Functionality A01 (15) FOUNDATION fieldbus Advanced Control Function Block Suite PlantWeb Diagnostic Functionality D01 (15) FOUNDATION fieldbus Diagnostics Suite DA1 (16) HART Diagnostic Suite PlantWeb Enhanced Measurement Functionality H01 (15)(17) Fully Compensated Mass Flow Block Special Configuration (Software) C (18) NAMUR alarm and saturation signal levels, high alarm C5 (18) NAMUR alarm and saturation signal levels, low alarm C6 (6)(18) Custom alarm and saturation signal levels, high alarm Note: Requires option code C1, custom software configuration. A Configuration Data Sheet must be completed, see page 59. C7 (6)(18) Custom alarm and saturation signal levels, low alarm Note: Requires option code C1, custom software configuration. A Configuration Data Sheet must be completed, see page 59. C8 (18) Low alarm (standard Rosemount alarm and saturation signal levels) Special Configuration (Hardware) D1 (18) Hardware Adjustment (zero, span, security) D External Ground Screw DA (18) Hardware Adjustment (zero, span, security) and External Ground Screw Conduit Electrical Connector GE (19) M12, -pin, Male Connector (eurofast ) GM (19) A size Mini, -pin, Male Connector (minifast ) Typical Model Number: 3051SFA D L 060 D C H P S 2 T A A 1A 3 (1) Provide the A dimension for Flanged, Flange-Lok, and Threaded Flo-Tap models. Provide the B dimension for Flange Flo-Tap models. (2) Available in remote mount applications only. (3) Requires PlantWeb housing and Hardware Adjustments option code D1. () Requires PlantWeb housing. (5) Available with output code A only. Available approvals are FM Intrinsically Safe, Non-incendive (option code I5) or ATEX Instrinsically Safe (option code I1). Contact an Emerson Process Management representative for additional information. (6) Not available with output protocol code B. (7) Applies to assembled flowmeter only, mounting not tested. (8) Isolation and Instrument valves not included in Traceability Certification. 2

22 , Rev EA The Annubar Flowmeter Series (9) Not available with Electronics Connection Platform 6. (10) Materials of Construction comply with metallurgical requirements within NACE MR0175/ISO for sour oil field production environments. Environmental limits apply to certain materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments. (11) Consult factory for availability. (12) Not available with Housing code 7J. (13) Not available with Output Protocol code F or option code DA1. (1) Available with Output Protocol code A and Plantweb housing only. (15) Requires PlantWeb housing and output code F. (16) Requires PlantWeb housing and output code A. Includes Hardware Adjustments as standard. Contact an Emerson Process Management representative regarding availability. (17) Requires Rosemount 3095 Engineering Assistant to configure. (18) Not available with Output Protocol code F. (19) Not available with Housing code 7J. Available with Intrinsically Safe approvals only. For FM Intrinsically Safe, Non-incendive approval (option code I5) or FM FISCO Intrinsically Safe approval (option code IE), install in accordance with Rosemount drawing to maintain NEMA X rating. 25

23 , Rev EA Pipe I.D. Range measured in inches (millimeters) See Rosemount 3051SFA ProBar Flowmeter Ordering Information on page 20 For pipes with an Inner Diameter (I.D.) Range / Pipe Wall Thickness not found in this table or with a line size greater than 12-in. (300 mm), choose option code Z and specify the exact pipe dimensions (I.D. and Pipe Wall Thickness) on the HART Configuration Data Sheet (CDS) on page 59. The Emerson process Management Sizing program will determine this code, based on the application piping. Sensor Size 1 Sensor Size 2 Sensor Size 1 Sensor Size 2 Sensor Size 1 Sensor Size 2 Nominal 2-in. (50 mm) 2 1 /2-in. (63.5 mm) 3-in. (80 mm) 3 1 /2-in. (89 mm) -in. (100 mm) 5-in. (125 mm) 6-in. (150 mm) 6-in. (150 mm) 7-in. (180 mm) 7-in. (180 mm) 8-in. (200 mm) 8-in. (200 mm) 10-in. (250 mm) 12-in. (300 mm) Line Size Max. O.D in. (66.68 mm) in. (80.98 mm) 3.75-in. (95.25 mm).25-in. ( mm) in. ( mm) 6.09-in. (15.79 mm) 6.93-in. ( mm) 6.93-in. ( mm) 7.93-in. (201.2 mm) 7.93-in. (201.2 mm) in. (26.08 mm) in. (26.08 mm) in. (298.5 mm) in. ( mm) Pipe Wall Thickness I.D. Option Inner Diameter (I.D.) Range ANSI Pipes Non-ANSI Pipes Range 1.78 to 1.81-in. (5.31 to 6.76 mm) to 0.55-in to 0.88-in. (1.7 to 12. mm) A to in. (6.79 to 9.23 mm) (1.7 to 13.8 mm) to 0.9-in. (1.7 to 11. mm) B to in. (9.25 to mm) to 0.17-in. (1.7 to 10.6 mm) C to in. (52.53 to mm) to 0.07-in. (1.7 to 10.3 mm) D to in. (56.06 to mm) to in to 0.8-in. (2.1 to 11. mm) B to 2.69-in. (59.00 to mm) (2.1 to 1.3 mm) to 0.17-in. (2.1 to 10.6 mm) C 2.70 to in. (62.7 to mm) to 0.35-in. (2.1 to 11.0 mm) D to 2.67-in. (66.01 to mm) to in. (2.1 to 13.1 mm) E 2.68 to in. (67.26 to mm) to in to 0.60-in. (2.1 to 11.7 mm) A to in. (69.90 to mm) (2.1 to 1.3 mm) to 0.16-in. (2.1 to 10.6 mm) B to in. (73.66 to mm) to in. (2.1 to 10.0 mm) C to in. (77.95 to mm) to 0.0-in (2.1 to 10.3 mm) D to in. (82.02 to 8.66 mm) to in to 0.96-in. (3.0 to 12.6 mm) B to 3.58-in. (8.68 to mm) (3.0 to 15.2 mm) to in. (3.0 to 9.8 mm) C 3.59 to 3.73-in. (90.1 to 9.8 mm) to 0.15-in. (3.0 to 10.5 mm) D to in. (9.87 to mm) to in to in. (3.0 to 13.0 mm) B to.026-in. (97.18 to mm) (3.0 to 15.2 mm) to 0.00-in. (3.0 to 10.2 mm) C.027 to.237-in. ( to mm) to in. (3.0 to 9.9 mm) D.238 to.37-in. ( to mm) to 0.01-in. (3.0 to 10.2 mm) E.38 to.571-in. ( to mm) 0.13 to 0.61-in to 0.81-in. (3. to 12.2 mm) A to.812-in. ( to mm) (3. to 15.6 mm) 0.13 to 0.37-in. (3. to 9.5 mm) B.813 to 5.07-in. ( to mm) 0.13 to in. (3. to 9.7 mm) C 5.08 to 5.29-in. ( to mm) 0.13 to 0.13-in. (3. to 10.5 mm) D to 5.72-in. ( to mm) 0.13 to 0.61-in to in. (3. to 9.9 mm) A to in. ( to mm) (3. to 15.6 mm) 0.13 to in. (3. to 8.3 mm) B to in. (16.33 to mm) 0.13 to 0.31-in. (3. to 7.9 mm) C to in. (15.08 to mm) 0.13 to in. (3. to 7.5 mm) D to 5.72-in. ( to mm) 0.13 to 1.35-in to in. (3. to 28.7 mm) A to in. ( to mm) (3. to 3. mm) 0.13 to in. (3. to 27.1 mm) B to in. (16.33 to mm) 0.13 to 1.05-in. (3. to 26.7 mm) C to in. (15.08 to mm) 0.13 to in. (3. to 26.3 mm) D 6.38 to 6.62-in. ( to mm) 0.13 to 0.61-in to 0.37-in. (3. to 9.5 mm) B to in. ( to mm) (3. to 15.6 mm) 0.13 to in. (3. to 5.5 mm) C 7.02 to in. (178.1 to mm) 0.13 to 0.26-in. (3. to 6.2 mm) D to 6.62-in. ( to mm) 0.13 to 1.35-in to 1.11-in. (3. to 28.3 mm) B to in. ( to mm) (3. to 3. mm) 0.13 to in. (3. to 2.3 mm) C 7.02 to in. (178.1 to mm) 0.13 to in. (3. to 25.0 mm) D to 7.62-in. ( to mm) to 0.73-in to 0.99-in. (6. to 12.6 mm) B to in. ( to mm) (6. to 18.5 mm) to 0.37-in. (6. to 9.5 mm) C to 8.00-in. (202.7 to mm) to in. (6. to 7.9 mm) D 8.01 to in. ( to mm) to 0.36-in. (6. to 9.2 mm) E to 7.62-in. ( to mm) to 1.7-in to in. (6. to 31. mm) B to in. ( to mm) (6. to 37.3 mm) to 1.11-in. (6. to 28.3 mm) C to 8.00-in. (202.7 to mm) to in. (6. to 26.7 mm) D 8.01 to in. ( to mm) to 1.10-in. (6. to 28.0 mm) E to in. ( to mm) to 1.70-in to in. (6. to 27.1 mm) A to in. ( to mm) (6. to 37.3 mm) to in. (6. to 27.5 mm) B to in. (22.87 to mm) to in. (6. to 25.7 mm) C to in. (25.53 to mm) to 0.95-in. (6. to 2.0 mm) D to in. ( to mm) to in. (6. to 25.9 mm) E to in. (279.0 to mm) to 1.70-in to in. (6. to 27.9 mm) B to in. ( to mm) (6. to 37.3 mm) to in. (6. to 23.0 mm) C to in. ( to mm) to in. (6. to 29. mm) D 26

Rosemount 3051CFA Annubar Flowmeter

Rosemount 3051CFA Annubar Flowmeter December 2013 Rosemount 3051 Rosemount 3051CFA Annubar Flowmeter The Rosemount 3051CFA Annubar Flowmeter utilizes the patented T-shaped sensor design that delivers best in class accuracy and performance.

More information

Rosemount 3051T In-Line Pressure Transmitter

Rosemount 3051T In-Line Pressure Transmitter Rosemount 3051T In-Line Pressure Transmitter Rosemount 3051T In-line Pressure Transmitters are the industry standard for Gage, and Absolute pressure measurement. The in-line, compact design allows the

More information

Rosemount Annubar Flowmeter Series

Rosemount Annubar Flowmeter Series Product Data Sheet 00813-0100-809, Rev EA Rosemount Annubar Flowmeter Series Industry leading integrated DP flowmeters are created when Annubar primary elements are packaged with Rosemount pressure transmitters

More information

Rosemount DP Flowmeters and Primary Elements

Rosemount DP Flowmeters and Primary Elements meters and Primary Elements Multivariable capabilities allow for real time fully compensated mass and energy flow Fully-Integrated Wireless Flowmeters allow for easy installation Minimize permanent pressure

More information

Rosemount DP Flowmeters and Primary Elements

Rosemount DP Flowmeters and Primary Elements Product Data Sheet Rosemount DP Flowmeters and Primary Elements Rosemount DP Flow Multivariable capabilities allow for real time fully compensated mass and energy flow Fully-Integrated Wireless Flowmeters

More information

Annubar Flowmeter Series

Annubar Flowmeter Series Reference Manual Appendix A Reference Data Annubar Flowmeter Series 3051SFA Ordering Information..................... page A-1 3051SFA Specifications........................... page A-10 3051CFA Ordering

More information

Annubar Flowmeter Series

Annubar Flowmeter Series 00813-0100-809, Rev CA Catalog 200 Annubar Flowmeter Series Best-in-Class integrated DP flowmeters are created when Annubar primary elements are packaged with Rosemount pressure transmitters Improved performance

More information

Rosemount 3051S Series of Instrumentation

Rosemount 3051S Series of Instrumentation Product Data Sheet 3051S Series delivers highest field performance and reliability SuperModule Platform provides a foundation for integrated pressure, flow, and level solutions IEC 62591 (WirelessHART

More information

Rosemount 3051 Pressure Transmitter

Rosemount 3051 Pressure Transmitter Product Data Sheet Rosemount 3051 Rosemount 3051 Pressure Transmitter THE PROVEN INDUSTRY LEADER IN PRESSURE MEASUREMENT Best-in-Class performance with up to 0.04% reference accuracy Industry first installed

More information

Rosemount 3051S Series of Instrumentation

Rosemount 3051S Series of Instrumentation Product Data Sheet January 2013 00813-0100-4801, Rev RA Rosemount 3051S Series of Instrumentation Scalable Pressure, Flow, and Level Solutions Innovation Reaching Across Your Operation With the Rosemount

More information

Rosemount 3051 Pressure Transmitter

Rosemount 3051 Pressure Transmitter Rosemount 3051 Pressure Transmitter Product Data Sheet April 2014 00813-0100-4001, Rev RC With the Rosemount 3051 Pressure Transmitter, you ll gain more control over your plant. You ll be able to reduce

More information

Rosemount DP Flowmeters and Primary Elements

Rosemount DP Flowmeters and Primary Elements Product Data Sheet March 2015 00813-0100-4485, Rev FB Rosemount DP Flowmeters and Primary Elements Multivariable capabilities allow for real time fully compensated mass and energy flow Fully-Integrated

More information

Rosemount Integral Orifice Flowmeter Series

Rosemount Integral Orifice Flowmeter Series Product Data Sheet HIGHLY ACCURATE SMALL-BORE FLOW MEASUREMENT CAPABILITY WITH MINIMAL INSTALLATION AND MAINTENANCE REQUIREMENTS Improves accuracy and repeatability in 1 /2-in., 1-in., and 1 1 /2-in. line

More information

Rosemount Compact Orifice Flowmeter Series

Rosemount Compact Orifice Flowmeter Series Product Data Sheet INTEGRATED DESIGN FOR LIMITED STRAIGHT PIPE RUN, CLOSED LOOP CONTROL, AND GENERAL PURPOSE MONITORING APPLICATIONS Reduced installation cost compared to a traditional orifice plate Accurate

More information

Rosemount 3051S Series of Instrumentation

Rosemount 3051S Series of Instrumentation Product Data Sheet May 2014 00813-0100-4801, Rev SA Rosemount 3051S Series of Instrumentation Scalable pressure, flow, and level solutions Innovation reaching across your operation With the Rosemount 3051S

More information

Rosemount 3051S Series

Rosemount 3051S Series Product Data Sheet Industry leading performance with 0.025% accuracy Industry s first %-of-reading flow transmitter delivering a 10x performance improvement Industry's first 10-year stability under actual

More information

Rosemount 3051S Electronic Remote Sensor (ERS) System

Rosemount 3051S Electronic Remote Sensor (ERS) System Rosemount 3051S Electronic Remote Sensor (ERS) System The Rosemount 3051S ERS System is a flexible, 2-wire 4-20 ma ART architecture that calculates differential pressure (DP) electronically using two pressure

More information

Rosemount 3051CF Flowmeter Series

Rosemount 3051CF Flowmeter Series September 2014 Rosemount DP Flow Rosemount 3051CF Flowmeter Series Rosemount 3051CFA Annubar Flowmeter The Rosemount 3051CFA Annubar Flowmeter utilizes the T-shaped sensor design that delivers best in

More information

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications Product Data Sheet Rosemount 3051 FIELDBUS PROTOCOL Hazardous Locations Certifications North American Certifications FM Approvals E5 Explosion-Proof for Class I, Division 1, Groups B, C, and D. Dust-Ignition-Proof

More information

Rosemount 285 Annubar Primary Element Series

Rosemount 285 Annubar Primary Element Series 0013-0100-02, Rev CA Rosemount 25 Annubar Primary Element Series Designed for general purpose applications Increased plant uptime with the maintenance-free design Energy savings gained through minimal

More information

Rosemount Engineered Assemblies

Rosemount Engineered Assemblies Product Data Sheet A single, high performance, engineered solution designed to meet the highest industry standards: Complete measurement solution, ready to install out of the box Designed and built to

More information

Rosemount DP Level Transmitters and 1199 Seal Systems

Rosemount DP Level Transmitters and 1199 Seal Systems Product Data Sheet FOR ROSEMOUNT 3051S, 3051, AND 2051 TRANSMITTERS APPLICATIONS Level, Flow, Pressure, Interface, Density Extreme hot and cold temperatures Corrosive, clogging, or viscous processes Hygienic

More information

Rosemount DP Level Transmitters and 1199 Remote Seals

Rosemount DP Level Transmitters and 1199 Remote Seals Product Data Sheet FOR ROSEMOUNT 3051S, 3051, AND 2051 TRANSMITTERS APPLICATIONS Level, Flow, Pressure, Interface, Density Extreme hot and cold temperatures Corrosive, clogging, or viscous processes Hygienic

More information

Rosemount 3095FT MultiVariable Flow Data Logger

Rosemount 3095FT MultiVariable Flow Data Logger Quick Installation Guide Rosemount 3095FT Rosemount 3095FT MultiVariable Flow Data Logger Step 1: Mount the Transmitter Step 2: Consider Housing Rotation Step 3: Set Jumpers and Switches Step 4: Connect

More information

Rosemount 3051S Series of Instrumentation

Rosemount 3051S Series of Instrumentation Product Data Sheet 00813-0100-4801, Rev UK December 2018 Rosemount 3051S Series of Instrumentation Innovation reaching across your operation With the Rosemount 3051S Series of Instrumentation, operations

More information

Rosemount DP Level Transmitters and 1199 Seal Systems

Rosemount DP Level Transmitters and 1199 Seal Systems Rosemount DP Level Transmitters and 1199 Seal Systems Product Data Sheet November 2013 00813-0100-4016, Rev NA Applications Level, Flow, Pressure, Interface, Density Extreme hot and cold temperatures Corrosive,

More information

Rosemount 2051 Pressure Transmitter

Rosemount 2051 Pressure Transmitter Product Data Sheet Rosemount 2051 Rosemount 2051 Pressure Transmitter Reference Accuracy of 0.075% Rangeability of 100:1 Protocols available include 4-20 ma HART, FOUNDATION fieldbus, 1-5 Vdc HART Low

More information

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES: Rosemount 1810 Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES: A cleanable and compact stainless steel design An innovative patented venting configuration that prevents gauge reference

More information

Rosemount 2051 Pressure Transmitter

Rosemount 2051 Pressure Transmitter Product Data Sheet Rosemount 2051 Rosemount 2051 Pressure Transmitter Reference Accuracy of 0.075% Rangeability of 100:1 Protocols available include 4-20 ma HART, FOUNDATION fieldbus, 1-5 Vdc HART Low

More information

Rosemount 1195 Integral Orifice Primary Element

Rosemount 1195 Integral Orifice Primary Element September 2014 Rosemount DP Flow Rosemount 1195 Integral Orifice Primary Element Rosemount 1195 Integral Orifice Primary Element utilizes a self centering orifice plate design to eliminate installation

More information

Rosemount 3095FC MultiVariable Mass Flow Transmitter with MODBUS Protocol

Rosemount 3095FC MultiVariable Mass Flow Transmitter with MODBUS Protocol Quick Installation Guide Rosemount 3095FC Rosemount 3095FC MultiVariable Mass Flow Transmitter with MODBUS Protocol Step 1: Mount the Transmitter Step 2: Connect Wiring Step 3: Set Jumpers and Apply Power

More information

Rosemount Integral Orifice Flowmeter Series

Rosemount Integral Orifice Flowmeter Series Reference Manual Rosemount Integral Orifice Rosemount 1195, 3051SFP and 3095MFP www.rosemount.com Reference Manual Rosemount Integral Orifice Rosemount Integral Orifice NOTICE Read this manual before

More information

Product Data Sheet , Rev GA Catalog Content

Product Data Sheet , Rev GA Catalog Content HIGHLY ACCURATE SMALL-BORE FLOW MEASUREMENT CAPABILITY WITH MINIMAL INSTALLATION AND MAINTENANCE REQUIREMENTS Improves accuracy and repeatability in 1 /2-in., 1-in., and 1 1 /2-in. line sizes Reduces leak

More information

Rosemount DP Level Transmitters and Remote Seals

Rosemount DP Level Transmitters and Remote Seals FOR ROSEMOUNT 3051S, 3051, AND 2051 TRANSMITTERS APPLICATIONS Level, Flow, Pressure, Interface, Density Extreme hot and cold temperatures Corrosive, clogging, or viscous processes Hygienic requirements

More information

Rosemount 3051 Pressure Transmitter

Rosemount 3051 Pressure Transmitter Product Data Sheet Rosemount 3051 Rosemount 3051 Pressure Transmitter THE PROVEN INDUSTRY LEADER IN PRESSURE MEASUREMENT Best-in-Class performance with 0.04% High Accuracy option Industry first installed

More information

Rosemount DP Level Transmitters and 1199 Diaphragm Seal Systems

Rosemount DP Level Transmitters and 1199 Diaphragm Seal Systems Rosemount DP Level Transmitters and 1199 Diaphragm Seal Systems Product Data Sheet December 2017 00813-0100-4016, Rev RF Applications Level, flow, pressure, interface, density Extreme hot and cold temperatures

More information

Rosemount DP Level Transmitters and 1199 Diaphragm Seal Systems

Rosemount DP Level Transmitters and 1199 Diaphragm Seal Systems Rosemount DP Level Transmitters and 1199 Diaphragm Seal Systems Product Data Sheet March 2017 00813-0100-4016, Rev RD Applications Level, flow, pressure, interface, density Extreme hot and cold temperatures

More information

Rosemount DP Level Transmitters and 1199 Seal Systems

Rosemount DP Level Transmitters and 1199 Seal Systems Rosemount DP Level Transmitters and 1199 Seal Systems Product Data Sheet March 2015 Applications Level, Flow, Pressure, Interface, Density Extreme hot and cold temperatures Corrosive, clogging, or viscous

More information

Rosemount 4088 MultiVariable Transmitter

Rosemount 4088 MultiVariable Transmitter Product Data Sheet January 2018 00813-0100-4088, Rev BA Rosemount 4088 MultiVariable Transmitter With the innovative Rosemount 4088 MultiVariable Transmitter, you can maximize your measurement accuracy

More information

Rosemount 485 Annubar Pak-Lok Assembly

Rosemount 485 Annubar Pak-Lok Assembly Quick Installation Guide 00825-0300-809, Rev EA Pak-Lok 85 Annubar Rosemount 85 Annubar Pak-Lok Assembly Start Step 1: Location and Orientation Step 2: Drill Holes into Pipe Step 3: Weld Mounting Hardware

More information

Rosemount 3095 MultiVariable Mass Flow Transmitter and Flowmeters

Rosemount 3095 MultiVariable Mass Flow Transmitter and Flowmeters Product Data Sheet THE PROVEN LEADER IN MULTIVARIABLE MASS FLOW MEASUREMENT. 1.0% Mass Flow rate accuracy over 10:1 Flow Range Ten year stability under actual process conditions Unprecedented reliability

More information

Rosemount 4088 MultiVariable Transmitter

Rosemount 4088 MultiVariable Transmitter Product Data Sheet May 2015 00813-0100-4088, Rev AC Rosemount 4088 MultiVariable Transmitter With the innovative Rosemount 4088 MultiVariable Transmitter, you can maximize your measurement accuracy and

More information

ProductDiscontinued Contents

ProductDiscontinued Contents Product Data Sheet THE PROVEN LEADER IN MULTIVARIABLE MASS FLOW MEASUREMENT 1.0% Mass Flow rate accuracy over 10:1 Flow Range Ten year stability under actual process conditions Unprecedented reliability

More information

Rosemount 3051 Pressure Transmitter

Rosemount 3051 Pressure Transmitter Product Data Sheet Rosemount 3051 Rosemount 3051 Pressure Transmitter THE PROVEN INDUSTRY LEADER IN PRESSURE MEASUREMENT Best-in-Class performance with 0.04% High Accuracy option Industry first installed

More information

Rosemount 1151 Pressure Transmitter

Rosemount 1151 Pressure Transmitter Product Data Sheet Rosemount 1151 Rosemount 1151 Pressure Transmitter Proven field performance and reliability Commitment to continuous improvement Reference accuracy of 0.075% Two-year stability of 0.1%

More information

Model 8800C Vortex Flowmeter

Model 8800C Vortex Flowmeter Vortex Flowmeter Start Step 1: Mount the Flowmeter Step 2: Consider Housing Rotation Step 3: Set the Jumpers Step 4: Connect the Wiring and Power Up Step 5: Review Flowmeter Configuration Product Certifications

More information

Rosemount 3051S Series of Instrumentation

Rosemount 3051S Series of Instrumentation Product Data Sheet Industry leading performance with 0.025% accuracy Industry s first %-of-reading flow transmitter delivering a 10x performance improvement Industry's first installed 10-year stability

More information

THE ROSEMOUNT 8800C DELIVERS RELIABILITY Rosemount Reliability -The 8800C Vortex eliates impulse lines, ports, and gaskets to improve reliabil

THE ROSEMOUNT 8800C DELIVERS RELIABILITY Rosemount Reliability -The 8800C Vortex eliates impulse lines, ports, and gaskets to improve reliabil E-MAIL: Vortex Flowmeter HART AND FOUNDATION FIELDBUS PROTOCOLS Available in wafer, flanged, dual, and reducer designs. Only manufacturer of Reducer Vortex which extends the measurable flow range, reduces

More information

Rosemount 485 Annubar Threaded Flo-Tap Assembly

Rosemount 485 Annubar Threaded Flo-Tap Assembly Quick Installation Guide 00825-0500-809, Rev DB Threaded Flo-Tap 85 Annubar Rosemount 85 Annubar Threaded Flo-Tap Assembly Step 1: Location and Orientation Step 2: Weld Mounting Hardware Step 3: Install

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO.: C3100L-E16B Smart Pressure Transmitter with Diaphragm Seal MODEL APT3100L DUON System Co., Ltd. 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200

More information

Rosemount 2051 Pressure Transmitter with HART 4-20 ma and HART 1-5 Vdc Low Power Protocol

Rosemount 2051 Pressure Transmitter with HART 4-20 ma and HART 1-5 Vdc Low Power Protocol Quick Installation Guide 00825-0100-4101, Rev EA June 2010 Pressure Transmitter with HART 4-20 ma and HART 1-5 Vdc Low Power Protocol CF Series Flowmeter Transmitter with HART 4-20 ma and HART 1-5 Vdc

More information

Rosemount 405 Compact Orifice Series

Rosemount 405 Compact Orifice Series Reference Manual Rosemount 405 Compact Rosemount 3051SFC Compact Orifice Flowmeter Rosemount 3095MFC Compact Orifice Mass Flowmeter www.rosemount.com Reference Manual Rosemount 405 Compact Rosemount 405

More information

Rosemount 3051 Pressure Transmitter

Rosemount 3051 Pressure Transmitter Rosemount 3051 Rosemount 3051 Pressure Transmitter HART AND FIELDBUS PROTOCOLS Industry s best total performance of ±0.15% Five year stability of ±0.125% Unmatched dynamic performance Coplanar platform

More information

Rosemount 585 Annubar Flanged Flo-Tap Assembly

Rosemount 585 Annubar Flanged Flo-Tap Assembly Quick Installation Guide 00825-0200-585, Rev AA Flanged Flo-Tap 585 Annubar Rosemount 585 Annubar Flanged Flo-Tap Assembly Start Step 1: Location and Orientation Step 2: Weld Mounting Hardware Step 3:

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. O.: C3700-L-E16A Smart Pressure Transmitter with Diaphragm Seal MODEL APT3700-L 298-29, GODA-RO, GUPO-SI, GYEOGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200 E-mail: autrol@duon.co.kr,

More information

Rosemount 285 Annubar Pak-Lok Assembly

Rosemount 285 Annubar Pak-Lok Assembly Quick Installation Guide 0025-0100-02, Rev AA Pak-Lok 25 Annubar Rosemount 25 Annubar Pak-Lok Assembly Start Step 1: Location and Orientation Step 2: Drill Holes into Pipe Step 3: Weld Mounting Hardware

More information

Rosemount 485 Annubar Flanged Assembly

Rosemount 485 Annubar Flanged Assembly Quick Installation Guide 00825-0100-809, Rev DB Flanged 85 Annubar Rosemount 85 Annubar Flanged Assembly Start Step 1: Location and Orientation Step 2: Drill Holes into Pipe Step 3: Assemble and Check

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO.: C3500L-E16A Smart Pressure Transmitter with Diaphragm Seal MODEL APT3500L 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200 E-mail: autrol@duon.co.kr,

More information

Armstrong In-Line and Insertion Vortex Flow Meters

Armstrong In-Line and Insertion Vortex Flow Meters Armstrong In-Line and Insertion Vortex Flow Meters Designs, materials, weights and performance ratings are approximate and subject to change without notice. Visit for up-to-date information. 1 In-Line

More information

Rosemount 8800D Series Vortex Flowmeter

Rosemount 8800D Series Vortex Flowmeter Product Data Sheet HART AND FOUNDATION FIELDBUS PROTOCOLS Available in wafer, flanged, dual, reducer and high pressure designs. Only manufacturer of Reducer Vortex which extends the measurable flow range,

More information

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter Product Data Sheet February 2015 IP119, Rev CA Displacer Level Transmitter Level, contents or interface measurement transmitter Direct or external chamber mounting 4 20 ma HART output ATEX Intrinsically

More information

SATRON VDt Differential Pressure Transmitter

SATRON VDt Differential Pressure Transmitter SATRON VDt differential pressure transmitter belongs to V-transmitter family. The series V transmitters have both analog and smart properties. SATRON VDt is used for -,1kPa...-15 MPa ranges. It is a 2-wire

More information

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction Sensing the pulse of industry tekvorx TV01 Multivariable Vortex flow Sensors Vortex flow sensors derive their name from a natural phenomenon of fluid dynamics. When a gas or relatively low viscosity liquid

More information

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter INTERPLANT STANDARD - STEEL INDUSTRY IPSS Specification for Smart Pressure & Differential Pressure Transmitter Corresponding IS does not exist IPSS: 2-07-104-15 1. Scope 1.1 This Interplant Standard covers

More information

Rosemount 8800D Series Vortex Flowmeter

Rosemount 8800D Series Vortex Flowmeter Product Data Sheet HART AND FOUNDATION FIELDBUS PROTOCOLS Available with optional MultiVariable output and temperature compensated mass flow for saturated steam. Available in wafer, flanged, dual, reducer

More information

SATRON VT Pressure Transmitter

SATRON VT Pressure Transmitter SATRON VT pressure transmitter belongs to the series V-transmitters. SATRON VT is used for 0-1.4 kpa...0-100 MPa ranges. It is a 2-wire transmitter with HART standard communication. In pressure measuring

More information

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T KROHNE 10/2001 7.02313.23.00 GR/OP Vortex Flowmeters F-T W-T Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level measuring

More information

STEEMCO-MAS Flowmeter for Steam

STEEMCO-MAS Flowmeter for Steam STEEMCO-MAS Flowmeter for Steam Typical Applications The STEEMCO-MAS flow meters measure the mass flow of superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical

More information

Micro Motion 7827 Digital Viscosity Meter

Micro Motion 7827 Digital Viscosity Meter Product Data Sheet PS-001217, Rev. C April 2013 Micro Motion 7827 Digital Viscosity Meter Micro Motion viscosity meters are built to tackle the most demanding process and control applications. Rugged and

More information

Rosemount Manifolds. Rosemount Manifolds. Product Data Sheet , Rev MA August Contents

Rosemount Manifolds. Rosemount Manifolds. Product Data Sheet , Rev MA August Contents Product Data Sheet Factory assembled, leak-tested, and calibrated Full breadth of offering including integral, conventional, and inline designs Integral design enables flangeless valve integration 2, 3,

More information

Rosemount Manifolds. Rosemount Manifolds. Product Data Sheet , Rev LA Catalog Contents

Rosemount Manifolds. Rosemount Manifolds. Product Data Sheet , Rev LA Catalog Contents Product Data Sheet Factory assembled, leak-tested, and calibrated Full breadth of offering including integral, conventional, and inline designs Integral design enables flangeless valve integration 2, 3,

More information

Smart Pressure Transmitter

Smart Pressure Transmitter DOC. NO.: C3200L-E16B Smart Pressure Transmitter with Diaphragm Seal MODEL APT3200L DUON System Co., Ltd. 298-29, GONDAN-RO, GUNPO-SI, GYEONGGI-DO, KOREA 15809 Tel : +82-31-3-6100 Fax : +82-31-29-7200

More information

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online... Multivariable Mass Vortex Flow Meter Features Volumetric or mass flow monitoring of gases, liquids and steam Smart electronics extends range down to a Reynolds number of 5000 Ideal for steam applications

More information

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric. Typical Applications EPSILON Flowmeter The EPSILON flow meters measure the flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical and the power

More information

VIM20 Vortex Insertion Flowmeter

VIM20 Vortex Insertion Flowmeter VIM20 Principle of Operation Vortex flowmeters measure flows of liquid, gas and steam by detecting the frequency at which vortices are alternately shed from a bluff body. According to proven laws of physics,

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance (033332_0_000) Issued to: Rosemount Inc. 6021 Innovation Blvd. Shakopee, Minnesota 55379-9795 USA Attention: Glen Edwards The products listed below are eligible to bear the CSA

More information

Rosemount 8800D Series Vortex Flowmeter

Rosemount 8800D Series Vortex Flowmeter Product Data Sheet HART AND FOUNDATION FIELDBUS PROTOCOLS Available with optional MultiVariable output and temperature compensated mass flow for saturated steam. Available in wafer, flanged, dual, reducer

More information

Series Level-Trol Electronic Liquid Level Transmitters

Series Level-Trol Electronic Liquid Level Transmitters 0- Level-Trol Series 0- Series Level-Trol Electronic Liquid Level Transmitters W0-/IL Non-Interactive Zero and Span Adjustments; Dry Span Calibration Allows Field Recalibration without Removing Wiring

More information

Level Measurement Point level measurement - RF Capacitance switches

Level Measurement Point level measurement - RF Capacitance switches Pointek CLS200 - Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level and material detection switch with optional rod/cable

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits Key Benefits Multivariable vortex flowmeter for measuring volumetric flow, temperature, pressure, density, and mass flow using a single meter Measures most gases, liquids and steam without the need to

More information

Rosemount Pipe Clamp RTD Sensor

Rosemount Pipe Clamp RTD Sensor Product Data Sheet Platinum RTD Temperature Sensors with silver or nickel tip Non intrusive design for measurement on pipe applications Temperature-sensor matching provides increased measurement accuracy

More information

ORIMAS Mass Flowmeter

ORIMAS Mass Flowmeter Typical Applications ORIMAS Mass Flowmeter The ORIMAS mass flow meters measure the mass flow of most liquids and gases within the process industries, including chemical, petro-chemical, pharmaceutical

More information

STEEMCO Flowmeter for Steam

STEEMCO Flowmeter for Steam STEEMCO Flowmeter for Steam Typical Applications The STEEMCO flow meters measure the flow of saturated and superheated steam within the process industries, including chemical, petro-chemical, pharmaceutical

More information

Multivariable Vortex Flow Meter

Multivariable Vortex Flow Meter Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version

More information

VLM20 In-line Vortex Flowmeter

VLM20 In-line Vortex Flowmeter ocal regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V Multivariable Flowmeter Model M24 In-line Vortex Pro-V TM Advantage: VorTek Instruments Pro-V multivariable flowmeters utilize three primary sensing elements a vortex shedding velocity sensor, an

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70054084 Issued to: Emerson - Rosemount, Micro Motion Inc. 12001 Technology Dr. Eden Prairie, Minnesota 55344 USA Attention: Paul Schilke The products listed below

More information

2600T Series Pressure Transmitter

2600T Series Pressure Transmitter Data Sheet 2600T Series Pressure Transmitter Model 261GS Gauge Model 261AS Absolute standard overload Base accuracy: ±0.15 % Span limits 0.3 to 60000kPa; 1.2inH 2 O to 8700psi 0.3 to 3000kPa abs; 2.25mmHg

More information

Multivariable Vortex Flow Meter

Multivariable Vortex Flow Meter Multivariable Vortex Flow Meter DVH Sensor Design w/o sealing Fully welded sensor Integrated temperature and pressure measurement (optional) Calculation of mass and density possible High temperature version

More information

SATRON VVFe Pressure Transmitter

SATRON VVFe Pressure Transmitter SATRON VVFe pressure transmitter belongs to Vtransmitter family. SATRON VVFe is used for 0 4 kpa...0500 kpa ranges. It is a 2wire transmitter with HART standard communication. SATRON VVFe pressure transmitter

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview. Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER F-2700 SERIES INSERTION VORTEX FLOW METER APPLICATIONS Saturated steam Hot water to 500 F (260 C) standard 750 F (400 C) optional Applications with optional pressure sensor Superheated steam to 500 F (260

More information

InnovaMass 240 & 241. Multivariable Mass Vortex Flow Meter. FEATURES DESCRIPTION

InnovaMass 240 & 241. Multivariable Mass Vortex Flow Meter.   FEATURES DESCRIPTION Multivariable Mass Vortex Flow Meter FEATURES Mass and volumetric flow measurement of gas, liquid, and steam Multivariable outputs for five process parameters: mass flow rate volumetric flow rate temperature

More information

Rosemount Magnetic Flowmeter Systems (Transmitter and Flowtube)

Rosemount Magnetic Flowmeter Systems (Transmitter and Flowtube) November 2003 Rosemount 8712D / 8700 Series Rosemount Magnetic Flowmeter Systems (Transmitter and Flowtube) ProductDiscontinued Start Step 1: Pre-Installation Step 2: Wiring Step 3: Basic Configuration

More information

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd Pointek CLS200 Standard Overview Configuration Installation Pointek CLS200 (standard version) is a versatile inverse frequency shift capacitance level switch with optional rod/cable choices liquids, solids,

More information

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

TEK-B AR 3110A. Differential Pressure Transmitter.   Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE Technology Solutions TEK-B AR 3110A Differential Pressure Transmitter PRESSURE www.tek-trol.com Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys Introduction The Tek-Bar 3110A Differential

More information

Transmitting Transducer. Gas/Air Velocity Range:

Transmitting Transducer. Gas/Air Velocity Range: RNG Series Insertion-Style Gas Flow Meter The RNG Series meter is an insertion-style vortex shedding flow meter designed to offer high accuracy measurements over an extremely large flow range. The meters

More information

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet All Metal Variable Area Flow Meter BGN Technical Data Sheet Extremely robust through star guiding system instead of guiding rod Flow metering of liquids, gases and steam Available up to nominal size of

More information

SATRON VTe pressure transmitter

SATRON VTe pressure transmitter SATRON VTe pressure transmitter belongs to the series V-transmitters which will have both analog and smart properties. SATRON VTe is used for 0-4 kpa...0-00 MPa ranges. The transmitter communicates in

More information