3/2 Solenoid Cartridge Valve, Size 6
|
|
- Philip Giles Lynch
- 6 years ago
- Views:
Transcription
1 / Solenoid Cartridge Valve, Size 6 Q max = 4 l/min ( gpm), p max = 5 bar (45 psi) Bidirectional seat-valve shut-off, direct acting Series W.B, WF.B Guided valve spool and poppet Two spool variants are available Available in two mounting versions With or without manual override Hand lever can be fitted on solenoid All exposed parts with zinc-nickel plating High pressure wet-armature solenoids The slip-on coil can be rotated, and it can be replaced without opening the hydraulic envelope Can be fitted in a line-mounting body escription The W / WF series of / solenoid operated directional seat valves are size 6, direct acting, pressure balanced, push-in cartridges. In the normal condition (de-energised), flow in port is shut off without leakage. The core element operates on the tried and tested principle of the guided poppet, and the guide spool has a seal. Two different mounting versions are available, which allows the designer to choose the insertion depth (flange. mm or 8 mm). The overlapped spool model (WF ) features a closed crossover characteristic i.e. during the valve's switching period (in the crossover position), there is no connection between ports,, and and therefore only a minimal loss of flow / pressure occurs. These cartridge seat valves are also available with or without manual override, and with the option of an additional hand lever. These valves are predominantly used in certain mobile and industrial applications where leak-tight shut-off functions are crucially important. Examples are where loads, tensions, or clamping forces must be held without leakage. All external parts of the cartridge are zinc-nickel plated to IN and are thus suitable for use in the harshest operating environments. The slip-on coils can be replaced without opening the hydraulic envelope and can be positioned at any angle through 6. If you intend to manufacture your own cavities or are designing a line-mounting installation, please refer to the section Related data sheets. Symbol Technical data General characteristics esignation esign escription, value, unit / solenoid cartridge valve bidirectional seat-valve shut-off, direct acting poppet and valve-spool design (pressure balanced) with underlapped or overlapped spool Mounting method push-in cartridge, 4 mounting bolts M5 x Tightening torque 5. Nm 5 % (4 ft-lbs 5 %) Size size 6, cavity type AC or cavity type A Weight.85 kg (.9 lbs) Mounting attitude unrestricted Reference: 4-P-6-EN- Issue:.7 /6
2 Hydraulic characteristics escription, value, unit Maximum operating pressure 5 bar ( 45 psi) Maximum flow rate 4 l/min ( gpm) Flow direction see symbols Hydraulic fluid HL and HLP mineral oil to IN 5 54; for other fluids, please contact BUCHER Ambient temperature range ) -5 C +8 C ( F +76 F) Hydraulic fluid temperature range -5 C +8 C ( F +76 F) Viscosity range Minimum fluid cleanliness Cleanliness class to ISO 446 : mm /s (cst), recommended mm /s (cst) class /8/5 Electrical characteristics escription, value, unit Supply voltage Supply voltage tolerance V C, 4 V C / 5 V AC, V AC (5 6 Hz) ± % Ambient temperature range ) -5 C +5 C ( F + F) Nominal power consumption V C = W / V AC = W Switching time Flow direction 8 (energising) 8 (deenergising) Flow direction 5 (energising) 9 (deenergising) These times are strongly influenced by fluid pressure, flow rate and viscosity, as well as by the dwell time under pressure. Relative duty cycle Protection class to ISO 65 / EN 6 59 Electrical connection % IP 65 / IP 67 / IP 69K, see Ordering code (with appropriate mating connector and proper fitting and sealing) IN EN 75-8, -pin P+E (standard) for other connectors, see Ordering code : ) The less favourable values from the hydraulic and electrical characteristics determine the temperature range of the whole valve. To ensure the performance data is not compromised, it is imperative to use coils 45/7 according to data sheet 4-P-. /6 4-P-6-EN-/.7 Series W.B, WF.B
3 4 Performance graphs measured with oil viscosity mm /s (cst), coil at steady-state temperature and % undervoltage p = f (Q) Performance limits [W] 5 (5) (4) 5 (6) (9) 5 () (4) 5 (7) P47.ai p = f (Q) Performance limits [WF] 5 (5) (4) 5 (6) (9) 5 () (4) 5 (7) P4.ai (.6) (5.) (8) 4 () (.6) (5.) (8) 4 () p = f (Q) Pressure drop - Flow rate characteristic [W ] (85) P48.ai p = f (Q) Pressure drop - Flow rate characteristic [WF ] 4 (57) P49.ai 6 () (7) 8 (5) 4 (6) (4) (85) (4) (.6) (5.) (8) 4 () (.6) (5.) (8) 4 () 4-P-6-EN-/.7 Series W.B, WF.B /6
4 5 imensions & sectional view 5. Shallow insertion model 5. eep insertion model (shown here without manual override) M A =.7 [Nm] % ft bls % 8.6 (.) 59. (.) ).4 (.6) 4.9 (.7) 9.9 (.66) 56.5 (.) Ø 45 Ø 45 (Ø.77) (Ø.77) 85.5 (.7) 57 (.4) 5.9 (4.96) (.) 8 (.7) 6.5 (.5) M5 4 (.57) 4 4 M A = 5. [Nm] 5% 4 ft bls 5% 6.4 (4.98). (.4) 5) 4) 5. Seal kit Seal kit no. S-467-N 6) Item Qty. 4 ) Qty. 5 ) escription O-ring no. 5 4, x,78 N9 O-ring no. 6 5,6 x,78 N O-ring no. 6 8,7 x,6 N O-ring no.,5 x,78 N9 4 O-ring, x, V8 4) WB / WFB / W / WF (Shallow insertion model) 5) WC / WFC / WE / WFE (eep insertion model) 6) Seal kit with FKM (Viton) seals, no. S-467-V 4) WG / WFG / WI / WFI (Shallow insertion model) 5) WH / WFH / WK / WFK (eep insertion model) ) Can be chosen with or without manual override. (see ordering code) When replacing an old coil with connection according to IN 465/ISO44 (with other Pin setup than according to datasheet 4-P-), the new coil can be mounted in 8 reversed position so that the existing plug (with 8 earthing- PIN) can be connected. This does not affect the performance data. 4/6 4-P-6-EN-/.7 Series W.B, WF.B
5 6 Installation information ATTENTION! Only qualified personnel with mechanical skills may carry out any maintenance work. Generally, the only work that should ever be undertaken is to check, and possibly replace, the seals. When changing seals, oil or grease the new seals thoroughly before fitting them. 7 Functional principle / Spool variants Underlapped spool (standard, W ) When fitting the cartridges, use the specified tightening torque for the mounting screws. No adjustments are necessary, since the cartridges are set in the factory. Overlapped spool (WF ) 8 Hand lever fitted on solenoid (optional) The overlapped spool model features a closed crossover characteristic i.e. during the valve's switching period, there is no connection between ports,, and and therefore only a minimal loss of flow/pressure occurs. This is a very important benefit in small-volume circuits, and in accumulator- and clamping systems. As an option, the WC... series of / solenoid operated directional seat valves are available with an additional hand lever. Two models can be supplied; the HHB hand lever with detent feature, and the HHNB hand lever without detent feature. Hand levers can only be fitted to valves that have a manual override. 8 (.) 6.5 (4.59) Ø 5 (Ø.98) 5.5 (.7) 5 7) 68.8 (6.8) 7.8 (4.64) Ø 45 (Ø.77) 7) Operated position 4-P-6-EN-/.7 Series W.B, WF.B 5/6
6 9 Ordering code W B B _ 4 _ + HHB _ W F = directional seat valve, de-energised closed = standard spool, / function, solenoid operated = overlapped spool, / function, solenoid operated Nitrile seals Viton seals Mounting depth (Cavity types AC and A) B G shallow = with manual override (not available with line-mounting body) C H deep = with manual override (with or without line-mounting body) I shallow = without manual override (not available with line-mounting body) E K deep = without manual override (with or without line-mounting body) A... Q = standard model - see relevant data sheets Z... R = special features - please consult BUCHER... 9 = design number, seat vlave (omit when ordering new units)... = voltage e.g. 4 (4 V) = current C A = current AC (connection only possible with IN EN 75-8) (blank) = IN EN 75-8 connection with mating plug (standard, IP 65) M = IN EN 75-8 connection without mating plug for the following plug-variants [mating plug not supplied], please consult Bucher: T = eutsch plug connection T4-P (with quenching diode, IP 67/69K) JT = Junior Timer radial plug connection (with quenching diode, IP 65) F = flying leads (6mm) (IP 65) without = without hand lever (standard) + HHB = with hand lever with detent + HHNB = with hand lever without detent... 9 = design number, hand lever (omit when ordering new units) Related data sheets Reference (Old no.) escription 4-P-4 (i-) The form-tool hire programme 4-P-4 (i-.) Cavity type AC and A 4-P- Coil for solenoid valve, series 45/7 4-P-7 (G-.) Line-mounting body, type GAA (G /8 ) info.ch@bucherhydraulics.com 7 by Bucher Hydraulics AG Frutigen, CH-74 Frutigen All rights reserved. ata is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Classification: /6 4-P-6-EN-/.7 Series W.B, WF.B
3/2 Solenoid Cartridge Valve, Size 6
/ Solenoid Cartridge Valve, Size 6 Q max = l/min, p max = 5 bar Bidirectional seat-valve shut-off, direct acting Guided valve spool and poppet Two spool variants are available Available in two mounting
More information2/2 Solenoid Cartridge Valve, Size 10
2/2 Solenoid Cartridge Valve, Size 1 Q max = 8 l/min, p max = 3 bar Seat-valve shut-off, two-stage, monitored operating position 1 Description With integral electronic monitoring of operating position
More informationProportional Flow-Control Cartridges, Size 5
Proportional Flow-Control Cartridges, Size Q max = l/min, p max = bar, Q N = l/min at p bar Leak free, load compensated, two stage Description Series MVRPLSA two-stage proportional flow-control cartridges
More information2/2 Solenoid Cartridge Valve, Size 6
/ Solenoid Cartridge Valve, Size 6 Q max = l/min (.3 gpm), p max = 3 bar (4 psi) Bidirectional leak-proof shutoff, direct acting, with EX-safty solenoid coil Description Valve: Bidirectional leak-proof
More information2/2 Cartridge Seat Valve, Size 5
/ Cartridge Seat Valve, Size Q max = l/min, p max = bar Digital valve, bidirectional seat-valve shut-off, direct acting Series WSGD / WSOD For use in digital hydraulics With bidirectional seat-valve shut-off
More informationElectrically Operated Pressure Relief Cartridge, Size 1 Seated Design, Direct Acting Series WUVA 1LO...
Electrically Operated Pressure Relief Cartridge, Size Seated Design, Direct Acting Series WUVA LO....5 l/min, 40 bar Wet armature solenoid with high pressure core tube and slip on coil Coils can be changed
More information2/2 Logic Cartridge Valve, Size 10
2/2 Logic Cartridge Valve, Size 10 Q max = 10 l/min, p max = 420 bar ctive Control, Seated Design ctive control rea ratio 2 : 1 High flow rates with low p Seat-valve shut-off from and No pilot oil consumption
More informationElectrically Operated Pressure Relief Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WUVPA 1...
Electrically Operated Pressure Relief Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WUVPA 1... 3 l/min, 420 bar Two pressure valve, ON / OFF or HI / LO With internal pilot drain to
More informationElectrically Operated Pressure Reducing Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WDRVPA 5...
Electrically Operated Pressure Reducing Cartridge, Size 16 Seated Pilot Stage, Spool Type Main Stage Series WDRVPA... 2 l/min, 3 bar Two pressure valve, HI / LO External pilot drain to port 3 Surface protection:
More information2/2 Logic Cartridge Valve, Size 10
2/2 Logic Cartridge Valve, Size 10 Q max = 10 l/min, p max = 420 bar ctive Control, Seated Design, Soft Switching 1 Description ctive control Soft switching, or soft switching + snap action Seated valve
More informationProportional Pressure Reducing Valve, Size 16 Series DRPSB 5B...
Proportional Pressure Reducing Valve, Size 16 Series DRPSB B... l/min, bar External pilot drain to port 3 Surface protection: Cartridge is chromited, Cr VI free Very stable operation Coil can be changed
More informationProportional Valves MODEL DESCRIPTION FLOW CAVITY 4/3 PROPORTIONAL DIRECTIONAL VALVE 8 GPM C1040 PDFC-4M PDFC-4L
Proportional Valves MODEL DESCRIPTION FLOW CAVITY 4 b a PDFC-4M 4/3 PROPORTIONAL DIRECTIONAL VALVE 8 GPM C040 4 3 b a PDFC-4L 3 3 EPRR-0 PROPORTIONAL PRESS. REDUCING/RELIEVING GPM C030 EPRT-08 PROPORTIONAL
More informationFlow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control
Flow Control Valve Series SRC.. plug-in coil for easy coil change flow rates are unaffected by changes in temperature or load compact design reduced p ZnNi coating (>70h DIN EN ISO 97 NSS) Description.
More informationCheck Valve, Size 04 16
, Size 04 6 Spherical poppet-type, screw-in design Series RKVE -VD 0 l/min, 50 bar for the same pressure differential, Q max. is around 50% higher than with standard RKVE valves no soft seal, therefore
More informationFlow Control Valve. 1 Description. 2 Symbols. Series SRCA General. 1.2 Application examples way flow control way flow control
Flow Control Valve Series SRC.. plug-in coil for easy coil change flow rates are unaffected by changes in temperature or load. compact reduced p ZnNi coating (>70h DIN EN ISO 97 NSS) Description. General
More informationPressure Relief Valve
ressure Relief Valve For mounting on hydraulic pumps and motors Series ASDF and AGDF S short response times S trouble-free operation S with improved pressure-adjustment resolution S high levels of functionality
More informationCheck Valves, Size Spherical Poppet-type, Screw-in Design Series RKVE l/min, 350 bar (500 bar)
Check Valves, Size 04... 40 Spherical Poppet-type, Screw-in Design Series RKVE... 360 l/min, 350 bar (500 bar) 1 General 1.1 Product description Series RKVE units are screw-in check valves with mounting
More informationDifferential Lock Valve
Differential Lock Valve Series M..DVD (for 3 motors) robust and reliable energy-optimised over the whole flow range simple control compact design offers space-saving installation reliable, uniform motion
More information2/2-way poppet valves with solenoid operation Type KSDER1
RE 8 36-0/0.0 Replaces: 07.0 /-way poppet valves with solenoid operation Type KSDER Build size T-3A cavity Maximum operating pressure 350 bar Maximum flow 0 L/min H/A/D 680/0 Type KSDER.A/HC... Overview
More informationLeak-Free Load-Control Valve NS 32, Cartridge Design
Leak-Free Load-Control Valve NS 32, Cartridge Design Q max = 1 l/min, p max = 42 bar Seat-valve, two-stage hydraulic 32--C... 1 Description Whenever large loads are to be precisely moved, placed and held,
More informationSD2E-A3. Functional Description. 3/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2013. Replaces HA /2012
3/2 Way Solenoid Operated Directional Control Valves Spool Type SD2E-A3 3/4-6 UNF p max 350 bar (5076 PSI) Q max 30 L/min (7.9 GPM) HA 404 /203 Replaces HA 404 07/202 Hardened and precision working parts
More informationSD3E-B2. Functional Description. 2/2 Way Solenoid Operated Directional Control Valves Poppet Type HA /2012. Replaces HA /2010
/ Way Solenoid Operated Directional Control Valves Poppet Type SD3E-B 7/8-4 UNF p max 40 bar (609 PSI) Q max 75 L/min (9.8 GPM) H 4063 7/0 Replaces H 4063 0/00 / way cartridge valves solenoid operated
More informationSD2E-A4. Functional Description. 4/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2012. Replaces HA /2010
4/2 Way Solenoid Operated Directional Control Valves Spool Type SD2E-4 /4-16 UNF p max 50 bar (5076 PSI) Q max 0 L/min (7.9 GPM) 7/2012 Replaces 10/2010 4/2 way cartridge valves solenoid operated spool
More information3/2 directional spool valve, direct operated with solenoid actuation
/ directional spool valve, direct operated with solenoid actuation RE 86-4/6. Replaces:.9 / Type KKDE (high-performance) Size Component series A Maximum operating pressure 5 bar Maximum flow 6 l/min H68
More informationSD2E-A4. Functional Description. 4/2 Way Solenoid Operated Directional Control Valves Spool Type HA /2014. Replaces HA /2013
/ Way Solenoid Operated Directional Control Valves Spool Type SDE- /-6 UNF p max 50 bar (5076 PSI) Q max 0 L/min (7.9 GPM) 07/0 Replaces 0/0 Hardened precision working parts High flow capacity High transmitted
More informationProportional Directional Valve System
roportional Directional Valve System in Sectional Design Reference: 31--9589-ENG-2 Issue: 8.215 1/2 Contents age 1 General... 3 1.1 Description... 3 1.2 pplication examples... 3 2 Technical data... 3 3
More information2/2 directional seat valve, direct operated with solenoid actuation
/ directional seat valve, direct operated with solenoid actuation RE 836-/0. Replaces: 06.08 /0 Type KSDE (High Performance) Component size 8 Component series B Maximum operating pressure 500 bar Maximum
More informationRPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007
Directional Control Valves Solenoid Operated RPE3-04 Size 04 (D 02) 320 bar (4600 PSI) 30 L/min (8.0 GPM) 10/2010 Replaces 12/2007 4/3-, 4/2- way directional control valves with solenoid control Solenoids
More information2/2 Solenoid Operated Seat Valve, ISO Size 03
2/2 Solenoid Operted Set Vlve, ISO Size 03 Q mx = 40 l/min (11 gpm), p mx = 315 r (4500 psi) Sndwich design, idirectionl lek-proof shutoff, direct cting, electriclly operted 1 Description 2 echnicl dt
More informationIntelligent Lift Control Valve with Electronic Card
Intelligent Lift Control Valve with Electronic Card Q max = 500 l/min, p max = 80 bar Leak-free, two-stage, electronically controlled, without frequency control i50 and i500 Information lift-control valve
More information4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid
01/08 /3, /2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid 2.1 Type WE 10...L5X Size (NG) 10 Up to 350 bar Up to 150 L/min Contents Function and configurations -03 Specifications 0 Symbols 05
More informationFlow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control
Flow Control Valve Series SRC.. plug-in solenoid for easy coil change flow rates are unaffected by temperature change or when the higher load pressure alternates between the outlet ports energy - optimised
More informationDirectional Control Valve Series 4D01 (DENISON)
Characteristics The Denison series 4D01 is a solenoid operated directional control valve size NG06 in -chamber design. It is direct operated by wet pin solenoids. The 4D01 is available with a Soft Shift
More informationFunctional Description
4/2 Way Solenoid Operated Directional Control Valves Spool SD2E-A4 Type 3/4-16 UNF p max 350 bar (5076 PSI) Q max 30 L/min (7.9 GPM) 01/2005 4/2 Way cartridge valves solenoid operated spool directed Manual
More informationDirectional cartridge valve tight on both sides type 2URED6 3
APPLICATION Directional cartridge valve type URED6 is intended for control direction of fluid flow, causing particular movement direction or stops a receiver (cylinder or hydraulic motor). The directional
More informationDifferential Lock Valve
Differential Lock Valve Series M..DVV (for 4 motors) robust and reliable energy-optimised over the whole flow range simple control compact design offers space-saving installation reliable, uniform motion
More information3/2 ways/positions flow diverters L (VS91-VS92-VS95)
3/2 ways/positions flow diverters L706... (VS91-VS92-VS95) RE 18302-03 Edition: 04.2016 Replaces: 02.2016 Size 12 Series 00 Maximum operating pressure 310 bar (4500 psi) Maximum flow 140 l/min (36.98 gpm)
More informationDifferential Lock Valve
Differential Lock Valve Series M..DVV (for 4 motors) robust and reliable energy-optimised over the whole flow range simple control compact design offers space-saving installation reliable, uniform motion
More informationStand alone 4/3, 4/2 solenoid operated directional valve
Stand alone 4/3, 4/2 solenoid operated directional valve (LF ) FAN DRIVE (LF ) RE 1835-4 Edition: 2.216 Replaces: 7.12 7.212 LF1 Size 6 LF2 Size 1 Series LF1 Maximum operating pressure 31 (45 ) LF2 Maximum
More informationCartridge Valves Technical Information Directional Valves DCV 03
OVERVIEW DCV 03 directional control valves consist of: housing (1), control spool (5), with two centering springs (4), and cylindrical operating solenoids (2, 3). The three-position directional valves
More informationSeated valves 500 bar
Seated valves 500 bar Type WVM-6I Features Solenoid actuated and direct operated Leakage free in every direction (double tight) High operational safety and reliable switching High duty cycles and long
More information4/3-4/2 Directional valve elements LF1_1 (LC1F-Z)
4/3-4/2 Directional valve elements LF1_1 LC1F-Z) RE 18305-01 Edition: 02.2016 Replaces: 07.12 07.2012 Size 6 Series 00 Maximum operating pressure 310 bar 4500 psi) Maximum flow 35 l/min 9.25 gpm) Ports
More informationDirectional Control Valves
Overview HYDAC offers several functions of the Directional Control Cartridges. HYDAC Manually operated position, - way normally closed, spring return, directional valve features poppet design. It offers
More informationDirectional Control Valve
Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. wide variety of spool options allows
More informationDirectional Control Valve Series D3W Soft Shift
Characteristics The D3W is a 3-chamber, electrically controlled 4/3 or 4/ way directional control valve. It is activated directly by solenoids with screwed in wet pin armature. The soft shifting of this
More informationDifferential Lock Valve
Differential Lock Valve Series M..DV (for 2 motors) robust and reliable energy-optimised over the whole flow range simple control compact design offers space-saving installation reliable, uniform motion
More informationProportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB
Proportional pressure relief valve, pilot-operated, with anti-cavitation function, decreasing characteristic curve Type KBVS.2DB RE 18377 Edition: 11.2017 Size 2 Series B Maximum working pressure 420 bar
More information4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections
4/3-4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections RE 183-52/7.12 Replaces: 1.9 1/8 8_8 (EDZ) Size 4 Series Maximum operating pressure 31 bar
More informationDirectional spool valves, direct operated, smoothly switching, with solenoid actuation
Directional spool valves, direct operated, smoothly switching, with solenoid actuation Type WE..73 A12 H7564 Features 4/2 or 4/3 directional design Porting pattern according to DIN 24340 form A Porting
More informationStand alone 4/3, 4/2 direct acting directional valve LF2_1 (LC2F-DZ)
Stand alone 4/3, 4/2 direct acting directional valve LF2_1 (LC2F-DZ) RE 18305-03 Edition: 02.2016 Replaces: 07.12 07.2012 Size 10 Series 00 Maximum operating pressure 250 bar (3600 psi) Maximum flow 90
More information6/2 ways/positions flow diverters L (VS120-VS125-VS129)
6/2 ways/positions flow diverters L710... VS120-VS125-VS129) RE 18302-04 Edition: 05.2014 Replaces: 07.12 Size 4 Series 00 Maximum operating pressure 310 bar 4500 psi) Maximum flow 25 l/min 6.6 gpm) Ports
More informationDL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min
41 211/118 ED DL3 SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO 4401-03 p max 280 bar Q max 50 l/min MOUNTING SURFACE OPERATING PRINCIPLE ISO 4401-03-02-0-05 (CETOP
More informationDirectional spool valves, direct operated, with solenoid actuation. Type WE
Directional spool valves, direct operated, with solenoid actuation Type WE RE 23178 Edition: 2013-06 Replaces: 04.09 Size 6 Component series 6X Maximum operating pressure 350 bar [5076 psi] Maximum flow:
More informationProportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 SK (high-performance)
Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 6 SK (high-performance) RE 64655 Edition: 7.218 Replaces: 11.216 Size 6 Series 3X Maximum control pressure
More informationunrestricted; preferably with coil at bottom (auto. air bleed) 12 or 24 Volt DC from an electronic controller Deutsch plug - IP67
3 Technical data General characteristics Design Flow direction Seals De-energized position Mounting attitude Description, value, unit line mounting P A controlled P R surplus flow discharge (models shown
More informationProportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 FK (high-performance)
Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 FK (high-performance) RE 64656 Edition: 07.18 Replaces: 11.16 Size 6 Series 3X Maximum control pressure
More information4/3-4/2 Directional valve with solenoid actuation
4/3-4/2 Directional valve with solenoid actuation RE 18305-08/12.13 1/10 L5110 LC1-Z ) Size NG6 ISO 4401-03 CETOP RP121 H-03 CETOP 3) Series 00 Maximum operating pressure 350 bar [5076 psi] Maximum flow
More information6/2 ways/positions flow diverters
6/2 ways/positions flow diverters RE 18302-07/07.12 Replaces: 12.09 1/8 L753... (VS311-VS312-VS315) Size 10 Series 00 Maximum operating pressure 310 bar [4500 psi] Maximum flow 140 l/min [36,98 gpm] Ports
More informationVS6M - SOLENOID OPERATED DIRECTIONAL VALVES
CONTINENTAL HYDRAULICS VS6M SOLENOID OPERATED DIRECTIONAL VALVES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VS6M SOLENOID OPERATED DIRECTIONAL VALVES
More informationDirectional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces:
Directional valve elements L80810P with proportional (ED4-PT1) control of Tank unloaded excess flow L80810P (ED4-PT1) RE 1801-1 Edition: 09.2016 Replaces: 07.12 01.2016 Size 6 Series 00 Maximum operating
More informationDirectional Control Valve Series D1VW
Characteristics The NG6 directional control valve series D1VW provides high functional limits up to 8 l/min in combination with a very low, energy-saving pressure drop. A wide variety of spool options
More informationMounting on manifold strip. Working pressure min./max. Max. particle size 5 µm. Connector standard ISO 15217
1 00137795 Version Spool valve, zero overlap Sealing principle Soft sealing Mounting on manifold strip P-strip Working pressure min./max. See table below Control pressure See table below min./max. Ambient
More informationPressure Control Valves
Control Valves DR8- Reducing/Relieving, Direct Acting, Spool Type 4 gpm (5 l/min) 6 psi (4 bar) Description A screw-in cartridge, direct acting, spool type, pressure reducing/relieving valve with internal
More information6/2 ways/positions flow diverters L (VS151-VS152-VS155)
6/2 ways/positions flow diverters L721... (VS151-VS152-VS155) RE 1832-5 Edition: 2.216 Replaces: 5.214 Size 6 Series 1 Maximum operating pressure 31 bar (45 psi) Maximum flow 6 l/min (15.85 gpm) Ports
More informationDSE /117 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 11 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min
83 2/117 ED DSE3 DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SUBPLATE MOUNTING ISO 41-3 p max 3 bar Q max l/min MOUNTING SURFACE OPERATING PRINCIPLE ISO 41-3-2-- (CETOP 4.2-4-3-3). 33 3.2 21. 12.7.1.7
More informationVSNG10 - SOLENOID OPERATED DIRECTIONAL VALVES
CONTINENTAL HYDRAULICS VSNG10 SOLENOID OPERATED DIRECTIONAL VALVES 5505 WEST 123RD STREET SAVAGE, MN 55378-1299 / PH: 952.895.6400 / WWW.CONTINENTALHYDRAULICS.COM VSNG10 SOLENOID OPERATED DIRECTIONAL VALVES
More informationRPEW4-06. Functional Description HA /2005. Solenoid Operated Directional Control Valves with Wirebox 1/2 NPT 1/2 NPT. Replaces HA /2004
Solenoid Operated Directional Control Valves with Wirebox RPEW4-06 2/2005 Size 06 p max up to 320 bar Q max up to 80 L/min Replaces 2/2004 4/3, 4/2 way directional control valves Four-land spool - reduced
More information4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections
RA 183-52/1.11 1/1 4/3 4/2 Directional valve elements with or without secondary relief valves, and with or without LS connections B8_8 (EDBZ) Summary Description Page General specifications 1 Ordering
More information6 to14/2 ways/positions bankable flow diverters flangeable
6 to14/2 ways/positions bankable flow diverters flangeable RE 18302-10/07.12 Replaces: 12.09 1/8 L745... (VS281F-VS285F-VS286F-VS287F-VS289F) Size 10 Series 00 Maximum operating pressure 310 bar [4500
More informationGPM PSI LPM BAR MODEL CAVITY PAGE IF-S3A special IF-S3D special IG-S4A special 198
Transmission & Brake Spool Valves Screw-in style GPM PSI LPM BAR MODEL CAVITY PAGE 2 1000 8 70 TC-S3A 5/8-18 186 6 1000 23 70 TF-S3A 7/8-14 188 6 1000 23 70 TF-S3D 7/8-14 190 5 1000 20 70 TG-S4A 7/8-14
More informationDirectional spool valves, direct operated, with solenoid actuation. Type WE. Features. Contents
Directional spool valves, direct operated, with solenoid actuation Type WE H7564 Features 4/3, 4/2 or 3/2 directional design High-power solenoid Porting pattern according to DIN 24340 form A Porting pattern
More information4/3 and 4/2 Proportional directional valve elements L8580 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING
/ and / Proportional directional valve elements L88 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING L88 (EDC-P) RE 181-9 Edition:.16 Replaces: 7.1 7.1 Size 6 Series Maximum operating pressure
More informationDirectional Controls
Vickers Directional Controls Wet Armature Solenoid Operated Directional Control Valves Model DGV-, Series Typical Construction of a Spring-Centered DC Valve with Variable Speed Pilot Control passage Speed
More informationInternal Gear Unit. for motor/pump function Series QXM. Reference: 100-P US-10 1/18. Issue:
Internal Gear Unit for motor/pump function Series QXM Reference: 1-P-63-US-1 Issue: 1.218 1/18 2/18 1-P-63-US-1/1.218 Contents Page 1 General... 5 1.1 Product description... 5 1.2 Advantages... 5 1.3 Application...
More information4/3 and 4/2 Proportional directional valve elements L8581 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING
4/3 and 4/2 Proportional directional valve elements L881 with flow (EDC-P1) sharing control (LUDV concept) PATENT PENDING L881 (EDC-P1) RE 1831-1 Edition: 6.218 Replaces: 7.12.217 Size 6 Series Maximum
More informationPressure limitation and feed valve, pilot-operated Type MHDBN...Y
Pressure limitation and feed valve, pilot-operated Type MHDBN...Y RE 64600 Edition: 06.2018 Sizes 22, 32 Series 3X Maximum working pressure 420 bar Maximum flow 400 l/min H8121 Features Screw-in cartridge
More informationProportional pressure relief valve, directly operated, rising characteristic curve
Proportional pressure relief valve, directly operated, rising characteristic curve RE 1139-0/09.07 Replaces: 0.05 1/1 Type KBPS.A (High-Performance) Component series A Maximum operating pressure 0 bar
More informationPilot Operated Directional Control Valves Series D31DW, D41VW - D111VW
Characteristics The D31, D41, D81, D91 and D111 are electrically controlled 4/3 or 4/ way directional control valves. The valves are pilot operated by an NG6 valve. Pressure and flow of the pilot oil have
More informationDSE3B /118 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SERIES 10 SUBPLATE MOUNTING ISO p max 350 bar Q max 40 l/min
83 215/118 ED DSE3B DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL SUBPLATE MOUNTING ISO 4401-03 p max 350 bar Q max 40 l/min MOUNTING INTERFACE OPERATING PRINCIPLE ISO 4401-03-02-0-05 (CETOP 4.2-4-03-350)
More informationRNEH4-25. Functional Description HA / /2 and 4/3 Way Directional Control Valves Pilot Operated. Replaces HA /2012
4/2 and 4/3 Way Directional Control Valves Pilot Operated RNEH4-25 HA 4024 7/2015 Size 25 (D 08) 320 bar (4600 PSI) 600 L/min (159 GPM) Replaces HA 4024 6/2012 Solenoid pilot operated directional valves
More information6 to 12/2 ways/positions bankable flow diverters flangeable
6 to 12/2 ways/positions bankable flow diverters flangeable RE 18302-08/07.12 Replaces: 12.09 1/8 L711... (VS120F-VS125F) Size 4 Series 00 Maximum operating pressure 310 bar [4500 psi] Maximum flow 20
More informationDirectional spool valves, direct operated, with solenoid actuation. Type WE. Contents. Features. RE Edition: Replaces:
Directional spool valves, direct operated, with solenoid actuation Type WE RE 23340 Edition: 2013-06 Replaces: 2012-06 Size 10 Component series 5X Maximum operating pressure 350 bar [5076 psi] Maximum
More informationSR1A-A2. Functional Description HA /2012. Directly Operated Pressure Relief Valves. Replaces HA /2010. Screw-in cartridge design
Directly Operated Pressure Relief Valves SRA-A2 HA 5063 7/202 3/4-6 UNF p max 350 bar (5080 PSI) Q max 30 L/min (7.9 GPM) Replaces HA 5063 8/200 Screw-in cartridge design 4 pressure ranges Pressure setting
More informationDirectional Control Valve Series D3W (Parker), 4D02 (Denison)
Characteristics Series D3W (Parker), 4D0 (Denison) The direct operated directional control valve size NG10 is available with both Parker (series D3W) and Denison (series 4D0) model codes. Both series are
More informationp max (see table of performances) Q max (see table of performances) bar Maximum flow rate from port P to A - B - T l/min
41 400/117 ED E*P4 PILOT OPERATED DISTRIBUTOR SOLENOID OR HYDRAULIC (C*P4) CONTROLLED E4P4 CETOP P05 E4R4 ISO 4401-05 E5 ISO 4401-08 p max (see table of performances) Q max (see table of performances)
More informationPilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW
Characteristics The pilot operated valves are available in 4 sizes: D31DW NG10 (standard) D31NW NG10 (high flow) D41VW NG16 D81VW NG5 (for port diameter up to 6 mm) D91VW NG5 (for port diameter up to 3
More informationProportional pressure reducing valve, direct operated, increasing characteristic curve Type DRE05SK
Proportional pressure reducing valve, direct operated, increasing characteristic curve Type DRESK RE 6469 Edition: 7.218 Replaces: 1.218 Size Series 1X Maximum control pressure 3 bar Maximum working pressure
More informationDirectional spool valves, direct operated, with solenoid actuation. Type WE. Features. Contents. RE Edition: Replaces: 04.
Directional spool valves, direct operated, with solenoid actuation Type WE RE 23178 Edition: 2013-06 Replaces: 04.09 Size 6 Component series 6X Maximum operating pressure 350 bar [5076 psi] Maximum flow:
More informationSolenoid directional valves Pmax 420 bar direct operated, ISO 4401 size 06 and size 10
Table TE030-0/E Solenoid directional valves Pmax 40 bar direct operated, ISO 440 size 06 and size 0 HEP-07*-** HEP; KEP, direct operated solenoid valves with max pressure up to 40 bar for heavy duty applications
More informationPilot control unit with end position lock for the remote control of directional valves
Pilot control unit with end position lock for the remote control of directional valves RE 64 553/02.07 1/12 Replaces : 05.05 Type 4THF6 or 5THF6 Series 2X Contents Functional description, section, symbol
More informationSolenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)
Hydraulic Screw-in Cartridge Valves (SiCV) Solenoid valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) Solenoid valves SOLENOID VLVES...- SV5-8-C/CM
More informationPilot-Operated Directional Control Valves Series D3 - D11
Catalogue HY11-500/UK Characteristics The D31, D41, D81, D91 and D111 are electrical controlled 4/3 or 4/ way directional control valves. The valves are pilot-operated by an NG6 valve. Pressure and flow
More information3/2 and 4/2 directional seat valves with solenoid actuation
1/16 3/2 and 4/2 directional seat valves with solenoid actuation RE 22049-XN-B2/08.12 Replaces: 07.10 Type M-.SED 6...XN... Size 6 Component series 1X Maximum operating pressure 350 bar Maximum flow 25
More informationSolenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.
Solenoid Valves Poppet and Spool type solenoid actuated valves for applications up to 5 bar (5 psi) and 7 L/min (6 USgpm) n Eaton Brand ETON Screw-In Cartridge Valves E-VLSC-MC-E November 9 -. Solenoid
More information3/2 and 4/2 directional poppet valve with solenoid actuation
Courtesy of CM/Flodyne/Hydradyne Motion Control Hydraulic neumatic Electrical Mechanical (800) 426-5480 www.cmafh.com 3/2 and 4/2 directional poppet valve with solenoid actuation ype M-.SED Size 10 Component
More informationPRM2-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013. Size 06 p max 350 bar Q max 40 L/min
Proportional Directional Control Valves Size 06 p max 50 bar Q max 40 L/min PRM-06 HA 5104 /014 Replaces HA 5104 /01 Compact design with integrated High reliability Simple replacement of the exciting coils
More information4/3 and 4/2 on-off directional valve elements L8511 with flow (EDC-DZ) sharing control (LUDV concept) L8511 (EDC-DZ)
4/3 and 4/2 on-off directional valve elements L8511 with flow (EDC-DZ) sharing control (LUDV concept) L8511 (EDC-DZ) RE 1831-11 Edition: 6.218 Replaces: 7.12 2.216 Size 6 Series Maximum operating pressure
More informationInternal Gear Unit. for motor/pump service Series QXM. Reference: 100-P EN-07 1/16. Issue:
Internal Gear Unit for motor/pump service Series QXM Reference: -P-63-EN-7 Issue: 8.215 1/16 Contents Page 1 General... 3 1.1 Product description... 3 1.2 Advantages... 3 1.3 Application... 3 1.4 ATEX
More informationChapter 2: Directional Control Valves
Contents Chapter : Directional Control Valves Series Description Direct operated Pilot operated Page DIN / ISO 06 10 16 5 3 10 16 5 3 Seat valves, electrically operated D1SE - Spool valves, electrically
More informationRPE3-04. Functional Description HA /2013. Directional Control Valves Solenoid Operated. Replaces HA /2010
Directional Control Valves Solenoid Operated RPE3-04 Size 04 (D 02) 320 bar (4600 PSI) 30 L/min (8.0 GPM) HA 4014 09/2013 Replaces HA 4014 10/2010 4/3-, 4/2- way directional control valves with solenoid
More information