Safety Roller Door RD344

Size: px
Start display at page:

Download "Safety Roller Door RD344"

Transcription

1 Original instructions Safety Roller Door RD Roller door with safe interlocking TLC7M00, rev. B ABB Jokab Safety Varlabergsvägen, SE- 9 Kungsbacka, Sweden

2 Read and understand this document Please read and understand this document before using the products. Please consult your ABB JOKAB SAFETY representative if you have any questions or comments. WARRANTY ABB JOKAB SAFETY s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by ABB JOKAB SAFETY. ABB JOKAB SAFETY MAKES NO WARRANTY OR REPRESENTATION, EXPRESSED OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS, ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OR THEIR INTENDED USE. ABB JOKAB SAFETY DISCLAIMS ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. LIMITATIONS OF LIABILITY ABB JOKAB SAFETY SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of ABB JOKAB SAFETY for any act exceed the individual price of the product on which liability asserted. IN NO EVENT SHALL ABB JOKAB SAFETY BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS ABB JOKAB SAFETY S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. SUITABILITY FOR USE ABB JOKAB SAFETY shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer s application or use of the product. At the customer s request, ABB JOKAB SAFETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE ABB JOKAB SAFETY PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PERFORMANCE DATA While every effort has been taken to ensure the accuracy of the information contained in this manual ABB JOKAB SAFETY cannot accept responsibility for errors or omissions and reserves the right to make changes and improvements without notice. Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of ABB JOKAB SAFETY S test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the ABB JOKAB SAFETY Warranty and Limitations of Liability. TLC7M00, rev. B

3 Table of Contents Introduction...5 Scope...5 Audience... 5 Prerequisites... 5 Special notes... 5 Preparations before installation...6 Check the manual and the parts of the door... 6 Space needed for the door... 7 Safety distance... 7 Important safety information... 7 To lift/move the door and its parts... 8 Description of the roller door safety devices...9 Mechanical installation...0 Exploded view with parts list... 0 Fixing points... Mounting instructions, step by step... Step Frame... Step Back Plate... Step Aligning... Step Attachment... Step 5 Fit the drive unit... 5 Step 6 Roller package... 5 Step 7 Centering Electrical installation...7 Cable requirements... 7 Electrical conditions... 7 Electrical installation, step-by-step... 7 Step 8 Drive unit... 7 Step 9 Electrical cabinet Adjustments, testing and mounting of cover plates...9 Final installation, step-by-step... 9 Step 0 Adjustment of the lower stop position... 9 Step Adjustment of the upper stop position... 9 Step Test run the door... 0 Step Adjustment of Eden sensors... 0 Step Fronts... 0 Stand for mounting... 7 Checklist for mechanical and electrical installation, test run and adjustments... 8 Troubleshooting... TLC7M00, rev. B

4 9 Maintenance... 0 Technical data...5 EC Declaration of Conformity...6 Connection examples...7 TLC7M00, rev. B

5 Introduction Scope These instructions contain information on the efficiency in the use of Safety Roller Door RD in accordance with the intended applications. These instructions constitute a part of the scope of the delivery. Audience This document is intended for authorized installation personnel. Prerequisites It is assumed that the reader of this document has knowledge of the following: Basic knowledge of ABB/Jokab Safety products. Knowledge of machine safety. Special notes Pay attention to the following special notes in the document: Warning! Caution! Danger of severe personal injury! An instruction or procedure which, if not carried out correctly, may result in injury to the technician or other personnel. Danger of damage to the equipment! An instruction or procedure which, if not carried out correctly, may damage the equipment. NB: Notes are used to provide important or explanatory information. 5 TLC7M00, rev. B

6 Preparations before installation Check the manual and the parts of the door Figure. - Tools that will be needed. Warning! Read through the manual before mounting the door. Warning! Electrical installations must be carried out by trained personnel only Check that the width and height of the supplied door match the actual opening (see section.). when mounting the door in ABB JOKAB Safety s Quick Guard system; that necessary parts of the fencing system are at hand. when mounting the door in other types of guarding or fixture; that it is of suitable strength and capable of rigidly supporting the door (see section.) that all components (according to delivery note) are at hand and undamaged, see parts list section.. NB! When installing the door it is of vital importance that the frame columns are erected absolutely vertically and the top roll perfectly horizontal. TLC7M00, rev. B 6

7 Space needed for the door 90 A DH 55 B DW 8 7 D D DETAIL B SCALE : SECTION A-A SCALE : A SECTION D-D SCALE : Safety distance The door must be placed in front of the machine/machines in such a way that the safety distance is fulfilled. The standard EN ISO 855 Safety of machinery Positioning of safeguards with respect to the approach speeds of parts of the human body gives the requirements especially for trip devices but could also be used as guidance when installing a Safety Roller Door. The installer has the responsibility to place the Safety Roller Door with such distance that all moving parts are stopped in a safe way when the operator reaches them. Important safety information When the door is mounted in front of a machine and the operator can pass the door and go into the machine, the door must be prevented from being closed and the machine being started while the operator is inside the machine area. One way of doing this, is to install a horizontal light curtain/s to protect the area/s where the operator can stand in the machine. Another way of securing that nobody is inside the risk area, when the door is to be operated downwards, is by timed reset. A facility like this is not a part of door and has to be ordered separately. Contact ABB/ JOKAB Safety for more information. If the door is going to be used as control guard it must be installed according to the requirements in EN 95 Safety of machinery General requirements for the design and construction of fixed and movable guards (see clause 5..9). 7 TLC7M00, rev. B

8 To lift/move the door and its parts How to safely lift the top roll Attach two slings, which are adequately rated and approved to lift the roll weight (Minimum 50 kg lifting capacity), around the top roll. Place the slings so that the top roll can be lifted securely and in balance without risk of tipping or dropping. Use lifting equipment that is approved and suitable for the size and weight of the top roll. Caution! Never lift the top roll, placed on a pallet unless the top roll is securely fixed. Fasten the frames when dismantling When the frames have to be dismantled the upper parts must be secured with appropriate lifting equipment. Fasten the drive unit when mounting/dismantling When the drive unit is to be mounted/dismantled it must be secured in appropriate lifting equipment. TLC7M00, rev. B 8

9 Description of the roller door safety devices To monitor the position of the door blade, the door is equipped with two PL e/category Eden sensors (contact free) in both sides of its frame. When the door is closed the Eden sensors are actuated and the machine is ready to be restarted. When the door starts to open, a stop signal is sent to the machine. As the door has Eden sensors on both sides, this prevents the door being lifted or pushed to one side without a stop signal being given to the machine. To protect personnel from being injured by the door it is equipped with a contact strip on the bottom beam profile. If the door hits a person the contact strip will be actuated, and the control system will reverse the door to its fully open position. 9 TLC7M00, rev. B

10 Mechanical installation Exploded view with parts list OPTION Figure. - Exploded view TLC7M00, rev. B 0

11 Pos No Title Note 0 Motor cover Right / left 0 Roller cover 0 Wall 0 Axle assembly 05 Bearing plate 06 Bearing 07 Roller 08 Roller moulding 09 Upper wall mounting Right 0 Frame profile Right Frame reinforcement Drive unit Motor plate Motor spacer 5 Upper wall mounting Left 6 Brush 7 Back plate 8 Guide wheel 9 Cover profile Left 0 Frame profile Left Electrical cabinet Cover profile Right Beam profile Door leaf 5 Guide fitting 6 Attachment bracket, cable chain 7 8 Screw MFT-TT M6x0 8 Decorative moulding (JSM T) 9 Anti-crush guard rubber 0 Fork bracket Contact strip Eden safety switch, EVA part Cable chain, end piece Adjustment plate 5 Fork moulding Left 6 Lower wall mounting Right 7 Cable chain 8 Decorative moulding, frame (JSM T) 9 Fork mounting Right Pos No Title Note 0 Lower wall mounting Left Eden safety switch, ADAM part End position damper End piece, m cable End piece, m cable 5 ULG joint clamp 6 Sealing strip 7 7 Cable, chain flex. 8 Motor cable 9 Limit position, cable 50 Supply cable 5 Handle Std extension with universal joint, gfa 5 Bend protection 5 Screw 5 Cable clamp 55 Spiral cable 56 Mounting bracket, motor cover 57 6 Screw 58 6 Nut 59 Screw 60 Key 7x8x00 / 6x6x95 6 Screw roller 6 0 Rivet 6 Screw M6x0 6 Main switch 65 Foil pressure 66 Emergency stop 67 6 Screw KT6 M6x0 68 Screw M6S M8x6 69 Screw M6S M8x0 70 Screw KT6 M6x0 7 Screw Mx 7 Screw MRX Mx6 7 Screw MRX Mx0 7 Nut Hexflange M6 75 Screw KT6 M6x6 76 Screw KT6 M6x Screw M6S M0x0 78 Screw M6S M8x6 79 Washer BRB 8. TLC7M00, rev. B

12 Pos No Title Note 80 Screw KT6 M6x 8 Nut 8 6 Nut 8 Screw MLC6S Mx 8 Manufacturing sign 85 Back plate, motor cover Option 86 Nut 87 Screw MF6S M8x6 88 Velcro fastener 89 Screw KT6 M6x 90 Nut 9 Screw KT6 M6x 9 Nut TLC7M00, rev. B

13 Fixing points A 50 DH+50 DW DH B DETAIL A SCALE : 75 DW 5 DETAIL B SCALE : C DETAIL C SCALE : 6 DW TLC7M00, rev. B

14 Mounting instructions, step by step All position numbers refer to the exploded view. See Figure. - Exploded view. Warning! Follow the instructions precisely when mounting the door. Not doing so runs the risk of the door falling down with personal injuries as a result. Step Frame Remove the cover profiles 9 and from frame profiles 0 and 0. Raise both frames, right and left respectively (0/0), against the wall on the respective sides of the door opening and attach them temporarily with the help of screw clamps. See Figure.. Protect the frame profiles to prevent scratches. Step Back Plate Mount the back plate (7) against the wall mountings upper edge. The back plate determines the distance between the frames. See Figure.. 0 Figure. 0 Step Aligning Align the door using a spirit level or an aligning instrument and check that the top seal is horizontal and that the frames are vertical. 7 Step Attachment The lower holes require a long drill (50 mm). Screw the door tight in the wall. Use the pre-drilled holes and at least M0 screws in the upper wall attachments (09/5) and the lower wall attachments (6/0). See Figure.. Figure. Figure. TLC7M00, rev. B

15 Step 5 Fit the drive unit The drive unit can be fitted on either the left side or the right side. Fit the motor attachment () on the gearbox. Use the thread lock on the screw s threads. See Figure.5. Mount the bearing plate (05) on the motor plate using motor spacers () and screw (68) See Figure.6. Place the key in the axle s key slot, slide the motor onto the axle. Figure.5 Figure.6 Step 6 Roller package Mount the bearing plate with bearing on the non-motor side. See Figure.7. The screws for the bearing shall not be tightened. Unscrew the two lower attachment screws on the bearing plate but leave the upper screw slightly loose so that it fits against the upper wall mounting. See Figure.7. Lift the roller into position with the bearing side first. Lower the roller so that the screw in the bearing plate fits into the wall mounting s long hole (place the bearing plate on the inside of the wall mountings). Fit the other four screws in the bearing plate and wall mounting. Remove the strap that secures the roller. Slide in the door fabric and guides in the frame. Fit the side with the safety sensor first. See Figure Figure.7 Figure TLC7M00, rev. B

16 Step 7 Centering Check that the roller package is centred between the frames wall attachments. See Figure.9. If necessary, adjust the roller laterally by carefully bending between the bearing plate and roller. Install the bearing s excenter-locking ring on the non-motor side and turn clockwise. Lock the locking ring by knocking it with hard blows for ½ - ¾ turn. Use a drift that is inserted in a pre-drilled hole. Tighten the locking screw. See Figure.0a-d. Tighten all the screws in the bearing. same distance locking ring with locking screw Figure.9 Figure.0a Figure.0b / - / Figure.0c Figure.0d TLC7M00, rev. B 6

17 5 Electrical installation Cable requirements Electrical supply via 5 conductor cable, phase, neutral, ground (min.5 mm ). Cable Colour marked cables core (.5 mm ) cable + earth for motor 8/0 core (0.75 mm ) cable for cam switches and safety circuits core (0.50 mm ) cable for contact strip. (Spiral Cable supplied) 6/8/0 core (0.50 mm ) cable for up/down/stop controls core (0.50 mm ) cable for machine interface Electrical conditions Electrical supply needed for the Safety Roller Door is phase, x 00V or x 0V. Motors for other voltage levels can be ordered. The drive unit has an electromagnetic brake, oil-cooled gearbox, thermo fuse and built in cam-box. Motor and connection blocks are protected according to IP5. Always use screw caps that preserve the IP class. (If the door is mounted in such a position that the drive unit could be affected by rain or wash-down then the motor should be fitted with an additional cover). Control voltage is VDC. NB! Before phase sequence (the rotation direction of the motor) is checked by running the door short distances, always initially, place the door in an half open position by using the motor crank. Then follow the instructions in Step Test run the door. Electrical installation, step-by-step Step 8 Drive unit Connecting the motor: Check that the motor is marked as follows: 60-5/08-0 Volt. (-phase system) If the supply voltage is 60-5 V the motor shall be Y-connected. See Figure 5. - Y-connection. If the supply voltage is 08-0 V the motor shall be D-connected. See Figure 5. - D-connection. Y U V W Y U V W U U V W U V W V W W U V Figure 5. - Y-connection Figure 5. - D-connection 7 TLC7M00, rev. B

18 Step 9 Electrical cabinet Make the connections as follows. See chapter Connection examples. Connection block Equipment L, L, L Electrical supply N, PE Neutral, Earth - (X) Supply for motor - (X) Connection of external button/signal for controlling door movement upwards 5-6 (X) Connection of external button/signal for controlling door movement downwards 7-8 (X) Connection of external button/signal for stopping the door 0 (X) Reset button (X) Reset button (X) Lamp in reset button -7 (X) Eden. Safety switch for supervision of closed position of the door. 8- (X) Eden. Safety switch for supervision of closed position of the door. -6 (X) Connection of contact strip 7- (X) Option: Focus II Receiver M 5-8 (X) Option: Focus II Transmitter M 50-5 Safety output; to be connected to the machine 5-5 Safety output; to be connected to the machine TLC7M00, rev. B 8

19 6 Adjustments, testing and mounting of cover plates Final installation, step-by-step Warning! The following steps must be carried out with with the electrical supply isolated from the door motor and controls. Step 0 Adjustment of the lower stop position Remove the cover of the cam switch box. In the box are the cam plates that set the cam switches. Check that the bolts fixing the bracket holding the cam switches are fully tightened. To operate the door; use the crank and put it in the location in the bottom of the motor. Disengage the brake with the brake handle and turn the crank. Follow the steps thoroughly to adjust the lower stop position. See Figure 6. - Cam switch. Put the door in closed position. Turn the cam plate for the CLOSE cam switch so that the cam is positioned in front of the switch. Tighten the locking screw with an Allen key. Operate the door to a half open position. Close the door again. Fine adjust the CLOSE stop position by turning the adjustment screw. The CLOSE SAFETY cam switch follows the adjustments made on the CLOSE cam switch. Fine adjustments can be made on CLOSE SAFETY by turning the adjustment screw. Cam Switch Lock screw Adjustments Figure 6. - Cam switch Step Adjustment of the upper stop position Operate the door to the fully open position and adjust the OPEN and OPEN SAFETY cam switches in the same way as in step 0. Important! The OPEN cam switch should be adjusted so that a distance of 60 mm is left between the upper part of the bottom beam profile and the top cover (0). The reason for this is to minimize the risk for personal injuries of squeezing hands or fingers between the bottom beam and top cover. 9 TLC7M00, rev. B

20 Step Test run the door Place the door in the half open position by using the crank. Then remove the crank and connect the electrical supply to the door. Push the OPEN (S) button (if fitted) on the control panel. Stop the door immediately by pushing the STOP button (S). -- If the door is moving upwards the phases are connected correct. -- If the door moves downwards two phases have to change places on the connection blocks (,, ). Always finally adjust the limit position cams in small steps to ensure that the door does not go past its end positions and is damaged. Disconnect all external OPEN signals. Release the emergency stop but be prepared to stop the door if necessary. Step Adjustment of Eden sensors Push the CLOSE (S) button on the control panel to close the door. Adjust both adjustment plates () until the door s guide rails (5) rest in the bottom of both the fork brackets (0). The locking head () is mounted on the guide fitting s right or left sides. See Figure 6.. Adjust the Eden ADAM sensor () so that it is positioned opposite the Eden EVA sensor at a distance of no more than 8 mm. See Figure 6.. Check that the two parts of the Eden sensor cannot physically collide when the door is manoeuvred up or down. Manoeuvre the door to its end positions several times and check that the safety equipment receives a signal when the door is in its closed position. Mount the front frame cover (9/) 5-8 mm 0 Figure 6. Figure 6. Step Fronts Lift the front (0) into position and screw it against the bearing plates collar. Mount the motor cover (0) on the motor, and wall (0) on the non-motor side. Install the cable duct protection and decorative moulding (8) for the frame cover. TLC7M00, rev. B 0

21 Stand for mounting Can be ordered separately for the Safety Roller Doors. 00 A DW+60 VKR 0x0x VKR 0x0x Pls 0x6 00 E 00 H DETAIL H SCALE : 5 0 VKR 0x0x DETAIL E SCALE : 5 VKR 0x0x VKR 0x0x DW VKR 80x0x DH+50 Pls 80x8x00 D D SECTION A-A SCALE : F A Drawing showing no pre-drilled hole for door frame 0 50 SECTION D-D SCALE : DETAIL F SCALE : 5 TLC7M00, rev. B

22 7 Checklist for mechanical and electrical installation, test run and adjustments Company Type Date Idendification number Measure Check Comment Check that bolts and rubber mounts for the drive unit are securely fixed. Check that cam switches for door open and closed are correctly adjusted. Check that the door in its upper stop position leaves a minimum distance of 60 mm between the upper part of the bottom beam and the top cover. Check that control signals/customer connected push puttons are installed and function correctly (e.g. correct direction of motion). Check that the contact strip is connected correctly and makes the door move to its fully open position when actuated. Check that the Eden sensors are correctly adjusted. Check that machine/ machines inside risk area is stopped correctly when door leaves its bottom position. Check that chosen safety distance is fulfilled and sufficient for the machinery to stop before operator can reach moving parts. TLC7M00, rev. B

23 8 Troubleshooting Operating the door when electrical supply is disconnected The door can be opened/closed manually by the crank for the drive unit. Place the crank in the tap in the bottom of the motor. Disengage the brake by pulling the brake handle and turn the crank at the same time. Warning! When the crank is placed in the tap in the bottom of the motor the electrical supply to the motor is automatically switched off. Electrical supply to the door should always be switched off via the line circuit breaker before the door is operated by the crank. Error indication Eden sensors The LED has the following states: LED Indication Description LED on Eden Green Green-Red (flashing) Red Eva within range, safety circuit closed; door closed. Eva within range; the door is closed but the signal is not OK. Eva out of range, safety circuit open; door open. TLC7M00, rev. B

24 9 Maintenance Company Type Date Idendification number Daily checks: Measure Check Comment Check that bolts and rubber mounts for the drive unit are securely fixed. Check that the door reverses to its upper position when the contact strip is actuated. Look for oil leaks from gearbox and shaft, Check that the door is undamaged. Check that the door is working correctly according to door controls. Monthly checks (or every 0,000 cycles interval): NB: Checks according to daily checks together with the following checks. Measure Check Comment Check the brake performance and cam switch settings by checking that the door when stopping at its upper stop position leaves a distance of 60 mm between the upper part of the bottom beam and the top cover, the door blade does not get crinkled in the bottom position TLC7M00, rev. B

25 0 Technical data Manufacturer Address Ordering data ABB JOKAB SAFETY Varlabergsvägen 9 Kungsbacka Sweden Safety Roller door + viewing window. Viewing window with weld splash protection. Daylight height & Daylight width. Mechanical characteristics Maximum size, door cloth 0 m² If a larger size is needed, contact ABB Jokab Safety AB. Maximum width Maximum height Speed, roller door Max. number of cycles/minute Material frames Material upper bracket 000 mm 500 mm m/s up/down (during continous operation hours a day) Aluminum extrusion mm steel painted black Electrical characteristics Driving unit Three-phase motor 00-5 VAC Hz General Protection class Colour Door fabric material Door fabric colour Sound absorption Motor and gearbox are delivered with IP5 rating. Frame - aluminium, door cloth - grey Other colours available on request. Multi-layer polyester fabric cloth with PVC, mm thick or transparent PVC. The viewing window can also be supplied with protection against welding flash light. (Removes 99% of the UV-transmision from the welding process) Grey (RAL 708), can be supplied with recessed window (only in full width). Other colours are available. approx. 0 db Ambient temperature 0 C to +55 When operating in temperatures below -5 C, the oil in the gear-box should be replaced with an oil suitable to withstand cold temperatures. Durability towards chemicals Ammoniac, sodium hydrate, phosphoric acid, tartaric acid, oxalic acid, hydrochloric acid, citric acid, acetic acid, oil, detergent, calcium chloride (contact ABB Jokab Safety for more specifications) Safety Control monitoring unit for roller door Outputs Monitoring of position of the roller door Contact strip ABB Jokab Safety s Safety-PLC, Pluto safe outputs for connection to machine/plant. Eden sensors one on each side of the door. Mounted on the bottom frame of the door fabric. The door motion is reversed if the contact strip is compressed. Safety level Category /PL e, in accordance with EN ISO TLC7M00, rev. B

26 EC Declaration of Conformity We ABB AB JOKAB Safety Varlabergsvägen 9 Kungsbacka Sweden EC Declaration of conformity (According to 006//EC, Annex A) declare that the safety components of ABB AB make with type designations and safety functions as listed below, are in conformity with the Directives 006//EC 006/95/EC 00/08/EC Authorised to compile the technical file Product Safety Roller Door with monitoring of closed position by contact free sensor Eden and safety-plc Pluto ABB AB JOKAB Safety Varlabergsvägen SE- 9 Kungsbacka Sweden Safety Roller Door / 50 / 700 Used harmonized standards EN ISO 00:00, EN ISO 89-:008, EN 606:005, EN 600-:006+A:009, EN 6066-:007, EN :005, EN :007, EN , EN 5078:997, EN 088+A:008 Other used standards EN 6508:00 Jesper Kristensson PRU Manager Kungsbacka Original TLC7M00, rev. B 6

27 Connection examples X L L L N PE X G U W V V F K 5 6 K 5 6 A A + - S 5 6 JSNA 0/VDC 5 X U V W N AC AC M M Y FRONT DOOR 0V Anmärkning Remark Rullport Safety RollerDoor Standard Konstr Design Ritad Drawn JS Godk Appr Datum Date Blad Sheet JS 0 Sidor Pages Ritn nr Drawing no Forts Cont RD V V S S5 X X Panel Extern S0 F S S X S Extern 6 5 S S 5 6 X IQ / IQ5 Upp / Panel S6 Extern 8 7 S S X IQ / IQ6 Ner / Panel 6 S5 7 8 S V 0V Anmärkning Remark Rullport Safety RollerDoor Standard Konstr Design Ritad Drawn JS Godk Appr JS Datum Date 0 Blad Sheet Sidor Pages Ritn nr Drawing no Forts Cont RD TLC7M00, rev. B

28 V SAFETY MAT/ SAFETY STRIP K S8 S9 S0 S S7 ADAM EVA ADAM EVA Focus Receiver Focus Transmitter X 5 dyn A 50 X 0 white white 5 brown 6 7 brown K brown white blue black grey 5 brown white blue black grey 5 EDEN EDEN Option 5 5 brown 8 blue 9 white green 0 yellow red grey pink brown blue white black grey A X Tina7A A +V 0V ID CL CH I0 I I I I I5 I6 I7 VDC Type: PLUTO B0 JOKAB SAFETY IQ0 IQ IQ IQ IQ IQ5 IQ6 IQ7 0L Q0 L Q Q0 Q0 IQ / IQ /6 IQ5 / IQ6 /6 Option Reset 0V L Q00 K K PLUTO A0 L Q0 Anmärkning Remark Rullport Safety RollerDoor Standard Konstr Design Ritad Drawn JS Godk Appr JS Datum Date 0060 Blad Sheet Sidor Pages Ritn nr Drawing no Forts Cont RD mm 80 mm S F K K A A T S S S 80 mm X Anmärkning Remark Rullport Safety RollerDoor Standard Konstr Design Ritad Drawn JS Godk Appr JS Datum Date 0 Blad Sheet Sidor Pages Ritn nr Drawing no Forts Cont RD000 5 TLC7M00, rev. B 8

29 5 5 6 W W OPTION 7 8 G/G 8 G/G W G/G OPTION G/G W9 G/G G/G FOCUS RECIVER M FOCUS TRANSMITTER M Safety output independent safty output PROCESS START OPTION OPTION MACHINE SAFETY STRIP Roller Door Anmärkning Remark Rullport Safety RollerDoor Standard Konstr Design Ritad Drawn JS Godk Appr JS Datum Date 0 Blad Sheet 6 Sidor Pages Ritn nr Drawing no Forts Cont RD TLC7M00, rev. B

30 TLC7M00, rev. B 0

Tina 11A Connection block

Tina 11A Connection block Original instructions Tina 11A Connection block ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

Tina 4A Connection block

Tina 4A Connection block Original instructions Tina 4A Connection block Instructions valid for versions of the product from ver. H ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read

More information

Tina 10A/B/C Adaptor unit

Tina 10A/B/C Adaptor unit Original instructions Tina 10A/B/C Adaptor unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

Smile 11 RA/-B Smile 12 RF/-G Reset button

Smile 11 RA/-B Smile 12 RF/-G Reset button Original Instructions Smile 11 RA/-B Smile 12 RF/-G Reset button ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this User Manual Please read

More information

FMC-1/2 Tina Muting unit

FMC-1/2 Tina Muting unit Original instructions FMC-1/2 Tina Muting unit ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this

More information

Sense7-series Non-contact coded safety switch

Sense7-series Non-contact coded safety switch Original instructions Sense7-series Non-contact coded safety switch ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please

More information

Smile 41 Push-button box with/without emergency stop

Smile 41 Push-button box with/without emergency stop Original instructions Smile 41 Push-button box with/without emergency stop ABB Jokab Safety Varlabergsvägen 11, 434 39 Kungsbacka www.abb.com/jokabsafety Read and understand this document Please read and

More information

EStrong-series Emergency Stop

EStrong-series Emergency Stop Original instructions EStrong-series Emergency Stop ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand

More information

MKey9-series Safety Interlock Switch with Guard Locking

MKey9-series Safety Interlock Switch with Guard Locking Original instructions MKey9-series Safety Interlock Switch with Guard Locking ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document

More information

Eden AS-i Proximity safety sensor

Eden AS-i Proximity safety sensor Original instructions Eden AS-i Proximity safety sensor ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand

More information

Please note! This model of Eden is obsolete and has been replaced by Eden DYN. Original instructions Eden Non-contact safety sensor

Please note! This model of Eden is obsolete and has been replaced by Eden DYN. Original instructions Eden Non-contact safety sensor Original instructions Eden Non-contact safety sensor ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand

More information

Knox Safety and process lock

Knox Safety and process lock Original instructions Knox Safety and process lock ABB Jokab Safety Varlabergsvägen 11, SE-434 39, Sweden www.abb.com/jokabsafety Read and understand this document Please read and understand this document

More information

Original instructions Eden OSSD Coded non-contact safety sensor

Original instructions Eden OSSD Coded non-contact safety sensor Original instructions Eden OSSD Coded non-contact safety sensor ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and

More information

SAFETY PRODUCTS. ASK-Series Safety Mat Product Manual

SAFETY PRODUCTS. ASK-Series Safety Mat Product Manual SAFETY PRODUCTS ASK-Series Safety Mat Product Manual 2TLC010047M0201_D ORIGINAL INSTRUCTIONS Read and understand this document Please read and understand this document before using the products. Please

More information

SAFET Y PRODUCTS. TT-Series Safety Edge Product Manual

SAFET Y PRODUCTS. TT-Series Safety Edge Product Manual SAFET Y PRODUCTS TT-Series Safety Edge Product Manual 2TLC010046M0201_B ORIGINAL INSTRUCTION S Read and understand this document Please read and understand this document before using the products. Please

More information

2NC (slow-action) Direct. Model. opening

2NC (slow-action) Direct. Model. opening Small Safety Limit Switch CSM DS_E_3_1 Smallest Class of Safety Limit Switches in the World Note: Contact your sales representative for details on models with safety standard certification. The world's

More information

Eden OSSD Coded non-contact safety sensor

Eden OSSD Coded non-contact safety sensor Original instructions Eden OSSD Coded non-contact safety sensor ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety Read and understand this document Please read and

More information

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping) Safety-door Switch D4BS The Special Activates a Direct Opening Mechanism to Open the Contacts and Shut Off Control Circuits when Protective Doors Are Opened on Machine Tools or Other Equipment CSM_D4BS_DS_E_6_1

More information

D4BS CSM_D4BS_DS_E_8_4

D4BS CSM_D4BS_DS_E_8_4 Safety-door Switch CSM DS_E_8_4 The Special Activates a Direct Opening Mechanism to Open the Contacts and Shut Off Control Circuits when Protective Doors Are Opened on Machine Tools or Other Equipment

More information

Multiple Limit Switch

Multiple Limit Switch Multiple Limit Switch CSM DS_E_1_1 A New Monoblock Multiple Limit Switch Incorporating a ead Box with a Tough ead and Ensuring igh Sealing Performance and a Mechanical Durability of 5,000,000 Operations

More information

M2S. Indicator Series with Square 40-mm Body. Indicator (Square) List of Models

M2S. Indicator Series with Square 40-mm Body. Indicator (Square) List of Models Indicator (Square) CSM DS_E_3_2 Indicator Series with Square 40-mm Body Same type of Indicator as those in the A3S-series Pushbutton Switch Easy panel mounting from the front and simple lamp replacement

More information

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models Long-barrel Inductive Proximity Sensor EE CSM_EE_DS_E Proximity Sensor with a Long Screw Length Increased tightening strength. Cable protectors provided as a standard feature. Increased indicator visibility.

More information

D4GS-N CSM_D4GS-N_DS_E_7_2

D4GS-N CSM_D4GS-N_DS_E_7_2 Slim Safety Door Switch D4GS-N CSM_D4GS-N_DS_E_7_2 Slim Safety Door Switches with IP67 Rating Slim design with a width of only 17 mm (three-contact models). Reversible design allowing either front or rear

More information

Digital display Pressure range ON/OFF output Linear output Model

Digital display Pressure range ON/OFF output Linear output Model Slim Digital Pressure Sensor E8CC with Built-in Microcomputer and Digital Display Withstands a pressure of 49 kpa and highly reliable. Incorporates a two-turn pressure adjuster ensuring easy pressure setting.

More information

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h) Mechatronic Analog Timer H3AM Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and

More information

Original instructions LineStrong-series Emergency Stop Grab Wire Safety Switch

Original instructions LineStrong-series Emergency Stop Grab Wire Safety Switch Original instructions LineStrong-series Emergency Stop Grab Wire Safety Switch ABB AB / Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/lowvoltage Read and understand this document

More information

2NC (slow-action) Direct. Model. opening

2NC (slow-action) Direct. Model. opening Small Safety Limit Switch D4F CSM_D4F_DS_E_5_2 Smallest Class of Safety Limit Switches in the World Note: Contact your sales representative for details on models with safety standard certification. The

More information

D4BL. Guard Lock Safety-door Switch

D4BL. Guard Lock Safety-door Switch Guard Lock Safety-door Switch D4BL CSM_D4BL_DS_E_5_1 Release Protective Cover Locks Using Controller Signals or Pushbutton Switches after the Cutting Tool Stops Moving Due to Inertia A mechanical lock

More information

Safety Limit Switch

Safety Limit Switch Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_4_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit

More information

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure Safety-door Switch D4NS CSM_D4NS_DS_E_5_2 Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch Lineup includes three contact models with 2NC/1NO and 3NC contact forms and

More information

A165E CSM_A165E_DS_E_11_2

A165E CSM_A165E_DS_E_11_2 Emergency Stop Switch (16-dia.) CSM DS_E_11_2 Separate Construction with Minimal Depth Direct opening mechanism to open contacts in emergencies, such as when they are welded. Conforms to EN 6947-5-5. Includes

More information

High Performance Door Albany RP300. ASSA ABLOY Entrance Systems

High Performance Door Albany RP300. ASSA ABLOY Entrance Systems High Performance Door Albany RP300 ASSA ABLOY Entrance Systems Albany RP300 Rapid opening and closing ensures short cycle times High reliability even after years of high numbers of cycles Safety limit

More information

SPEEDROLLER SERVICE MANUAL CE DECLARATIONS LOG BOOK USER MANUAL. Edition : May 2011

SPEEDROLLER SERVICE MANUAL CE DECLARATIONS LOG BOOK USER MANUAL. Edition : May 2011 SERVICE MANUAL CE DECLARATIONS LOG BOOK USER MANUAL SPEEDROLLER Edition : May 2011 1 8 2 3 4 Main components 1 drive 2 wind roller with hood (optional) 3 door panel 4 aluminium hinge profile 5 window section

More information

G3PE-Single-phase. Solid State Relays for Heaters

G3PE-Single-phase. Solid State Relays for Heaters Solid State Relays for Heaters Single-phase CSM_Single-phase_DS_E Compact, Slim-profile SSRs with Heat Sinks. s with No Zero Cross for a Wide Range of Applications. RoHS compliant. s also available with

More information

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.) CSM_A165S_W_DS_E_4_1 Separate Construction with Cylindrical 16-dia. Body Same separate construction as the A16-series Pushbuttons with Miniature

More information

Safety stop buttons Smile, INCA and Compact

Safety stop buttons Smile, INCA and Compact Smile, INCA and are used to safely stop a certain part of a dangerous machine. ABB offers safety stop buttons to suit different needs of connection and communication. Models are available for e.g. external

More information

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings Motor Time Switch H2F-WM CSM_H2F-WM_DS_E_2_1 Weekly ON/OFF Control in 1-h Increments The H2F-WM is a Compact Weekly Time Switch in a DIN -mm Body Equipped with Power Interruption Backup Providing Protection

More information

XW2R-COM. Common Terminals X W 2R - P D - COM. Space-saving and less wiring work of power supply wiring are achieved. Application Example

XW2R-COM. Common Terminals X W 2R - P D - COM. Space-saving and less wiring work of power supply wiring are achieved. Application Example Common Terminals XW2R-COM CSM_XW2R-P_M_B-COM_DS_E Space-saving and less wiring work of power supply wiring are achieved. Common wiring is already wired on the PCB, transition wiring is unnecessary. Wiring

More information

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment Safety-door Hinge Switch CSM DS_E_4_1 Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment Note: Contact your sales representative for details on models

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Notes Regarding Safety...3 4 Intended Area of Application...4 5 Technical Data...5

More information

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet Small Sealed Switch D4E-N CSM_D4E-_N_DS_E_4_ Slim and Compact Switch with Better Seal and Ensuring Longer Service Life than D4E Flat springs with an improved lever ratio of the built-in switch ensure smooth

More information

D4BL. Guard Lock Safety-door Switch

D4BL. Guard Lock Safety-door Switch Guard Lock Safety-door Switch D4BL CSM_D4BL_DS_E_7_1 Release Protective Cover Locks Using Controller Signals or Pushbutton Switches after the Cutting Tool Stops Moving Due to Inertia A mechanical lock

More information

Model Number Legend (Completely Assembled)... Shipped as a set which includes the Operation Unit, Lamp (lighted models only), and Switch. 4.

Model Number Legend (Completely Assembled)... Shipped as a set which includes the Operation Unit, Lamp (lighted models only), and Switch. 4. Emergency Stop Switch (-dia./5-dia.) AE CSM_AE_DS_E_7_ Install in -dia. or 5-dia. Panel Cutout Direct opening mechanism to open the circuit when the contact welds. Safety lock mechanism prevents operating

More information

Model Number Structure

Model Number Structure Solid State Relays CSM OEE_DS_E_1_2 Extremely Thin Relays Integrated with Heat Sinks Downsizing achieved through optimum design of heat sink. Mounting possible via screws or via DIN track. Close mounting

More information

NEW GEN OWNER S MANUAL

NEW GEN OWNER S MANUAL NEW GEN OWNER S MANUAL For Models: LT-ELP223Q LT-ELP116Q 1 2! Turn off the light when not in use to conserve battery power. CAUTION! If you need to mount the flashlight onto a firearm, make sure firearm

More information

Features. Emergency Stop Switch A165E. Separate Construction with Smallest Class of Depth in the World. Safety Lock Prevents Misuse

Features. Emergency Stop Switch A165E. Separate Construction with Smallest Class of Depth in the World. Safety Lock Prevents Misuse Emergency Stop Switch Separate Construction with Smallest Class of Depth in the World Direct opening mechanism to open contacts in emergencies, such as when they are welded. Conforms to EN418. Includes

More information

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator Miniature Limit Switch CSM DS_E_3_3 Many Models Including Roller Lever Switches are Only -mm Thick with Connector New center roller lever models that enable ganged mounting of up to 6 Switches. Cable connectors

More information

Safety interlock switch MKey

Safety interlock switch MKey Safety interlock switch MKey MKey are mechanical safety switches used for monitoring doors and hatches. The switch is mounted on the frame and the actuator key on the moving part of the guard. All MKey

More information

DIN Track Terminal Blocks with Screw Terminals

DIN Track Terminal Blocks with Screw Terminals New Product DIN Track Terminal Blocks with Screw Terminals XW5T Global-standard DIN Terminal Blocks for Control Panels Wires held with screws. Compatible with a wide range of wire sizes with a nominal

More information

DIN Track Terminal Blocks with Screw Terminals XW5T

DIN Track Terminal Blocks with Screw Terminals XW5T New Product DIN Track Terminal Blocks with Screw Terminals XW5T Global-standard DIN Terminal Blocks for Control Panels Wires held with screws. Compatible with a wide range of wire sizes with a nominal

More information

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K Guard Lock Safety-door Switch D4BL CSM_D4BL_DS_E_10_1 Die-cast aluminum body Key holding force of 700 N Auxiliary release key ensures easy maintenance and unlocks the door in the case of a power failure.

More information

S8JX-N/S8JX-G Series Replacement Brackets

S8JX-N/S8JX-G Series Replacement Brackets Original model mounting method Bottom mounting Front mounting Side mounting Original model: S8JX-N/S8JX-G Replacement model: S8FS-G Replacement bracket Model scheduled to be discontinued Recommended replacement

More information

Safety Guard Switching Unit G9SX-GS

Safety Guard Switching Unit G9SX-GS Enabling Grip Switch CSM DS_E_5_1 Enabling Grip Switch with Distinct Feel for Three Easily Discernible Positions The difficult task of configuring safety circuits is now easily achieved by combining the

More information

D4NH CSM_D4NH_DS_E_7_1

D4NH CSM_D4NH_DS_E_7_1 Safety-door Hinge Switch D4NH CSM_D4NH_DS_E_7_1 Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment Lineup includes three contact models with 2NC/1NO

More information

RITE-HITE VHLS. Vertical Under-Leveler Seal Installation Instructions & Owner s Manual. Date of Installation:

RITE-HITE VHLS. Vertical Under-Leveler Seal Installation Instructions & Owner s Manual. Date of Installation: RITE-HITE VHLS Vertical Under-Leveler Seal Installation Instructions & Owner s Manual Date of Installation: This Manual Covers All Units Shipped 4/2014 to Date PRINTED IN U.S.A. PUBLICATION VHLS0003 REV.

More information

ZB0050 / ZB0051 ZB0070 / ZB0071

ZB0050 / ZB0051 ZB0070 / ZB0071 Operating instructions Safety Rope Emergency Stop Switches UK ZB0050 / ZB0051 ZB0070 / ZB0071 7390877 / 02 08/2013 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4 2.2

More information

DIN Track Terminal Blocks with Screw Terminals XW5T

DIN Track Terminal Blocks with Screw Terminals XW5T New Product DIN Track Terminal Blocks with Screw Terminals XW5T Global-standard DIN Terminal Blocks for Control Panels Wires held with screws. Compatible with a wide range of wire sizes from 0.14 to 185

More information

Pro Series 2120 COMMERCIAL ROLLER SHUTTER OPENER

Pro Series 2120 COMMERCIAL ROLLER SHUTTER OPENER AUTOMATIC TECHNOLOGY AUSTRALIA PTY LTD Pro Series 2120 COMMERCIAL ROLLER SHUTTER OPENER OWNERS COPY Installation Instructions WARNING It is vital for the safety of persons to follow all instructions. Failure

More information

Effective June 2016 New Issue

Effective June 2016 New Issue Voltage Regulators MN225035EN Effective June 2016 New Issue COOPER POWER SERIES QD8 Quik-Drive Tap-Changer Switch Assembly Kit 5740785B13 and Switch Neutral Stationary Assembly Kit 5791646A48 Installation

More information

Instruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1

Instruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1 Instruction Manual ThinkTop D30 2064-0000_1 Patented Sensor System Registered Design Registered Trademark ESE02248-EN3 2014-12 Original manual Table of contents The information herein is correct at the

More information

SERVICE MANUAL. Permobil C350. Power Wheelchair

SERVICE MANUAL. Permobil C350. Power Wheelchair SERVICE MANUAL US Permobil C350 Power Wheelchair Contents Contents Introduction... 5 Rating plates... 6 Covers... 8 Batteries... 10 Rear wheels... 12 Support wheels... 14 Front wheels... 16 Wheel fork...

More information

A22LK CSM_A22LK_DS_E_6_2

A22LK CSM_A22LK_DS_E_6_2 Guard Lock Safety Key CSM DS_E_6_2 The guard lock prevents accidental mode changes. for secure equipment activation during maintenance The guard lock of the Operation Unit prevents incorrect operation.

More information

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions Voltage Regulators MN225025EN Effective March 2016 Supersedes S225-50-48 November 2008 COOPER POWER SERIES QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit 5791646A26 installation

More information

Small transport belts single-lane, double-lane

Small transport belts single-lane, double-lane Small transport belt, single-lane Small transport belt, double-lane Specifications may change as design revisions take place; closing date: 32/2013 All rights reserved The copyright owner of this documentation

More information

LT-EL138 LED Flashlight

LT-EL138 LED Flashlight LT-EL138 LED Flashlight 1 2! CAUTION! If you need to mount the flashlight onto a firearm, make sure firearm is not loaded before installation. Remove magazine and examine chamber. Use safe handling procedures

More information

Owner s Manual, Operating Instructions Manual, and Replacement Parts Manual. Lift-Rite Hand Pallet Trucks Model PST Plus

Owner s Manual, Operating Instructions Manual, and Replacement Parts Manual. Lift-Rite Hand Pallet Trucks Model PST Plus Owner s Manual, Operating Instructions Manual, and Replacement Parts Manual Lift-Rite Hand Pallet Trucks Model PST Plus This publication, 1269849/001B, applies to the Lift-Rite Hand Pallet Truck, Model

More information

Lift-N-Glide Manual. Lifter Serial Number: Lift Mast Serial Number: Intermediate Member Serial No:

Lift-N-Glide Manual. Lifter Serial Number: Lift Mast Serial Number: Intermediate Member Serial No: Lift-N-Glide Lift-N-Glide Manual 1 Lifter Serial Number: Lift Mast Serial Number: Intermediate Member Serial No: 2 TABLE OF CONTENTS 1 Introduction... 3 2 Safety... 4 3 Warranty... 4 3.1 Warranty... 4

More information

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s.   PEGAS E Smart Manual EN 04 WELDING INVERTER PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL PEGAS 160-200 E Smart Manual EN 04 2/12 CONTENT: 1. INTRODUCTION... 3 2. SAFETY INSTRUCTIONS AND WARNINGS... 4 3. TECHNICAL DATA...

More information

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination

3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination 3M Cold Shrink Silicone Rubber Termination QT-III 7600-S-3G Series Three-Core Outdoor Termination Instructions IEEE Std. No. 48 Class 1 Termination CAUTION Working around energized electrical systems may

More information

Motor-drive mechanism, type BUL. Technical guide

Motor-drive mechanism, type BUL. Technical guide Motor-drive mechanism, type BUL Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required

More information

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits

3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits 3M Cold Shrink QT-III Silicone Rubber Three-Core Termination Kits With High-K Stress Relief For 3-Conductor Type G (Ground Wire), Copper Tape Shield, Armored Cables 7600-S-3G Series Instructions IEEE Std.

More information

Installation and Operation Instructions Safety Director Arrow

Installation and Operation Instructions Safety Director Arrow Installation and Operation Instructions Safety Director Arrow! WARNING! Failure to install or use this product according to manufacturers recommendations may result in property damage, serious bodily/personal

More information

Pan and Tilt Head CDD2416-T

Pan and Tilt Head CDD2416-T Pan and Tilt Head CDD2416-T Installation guide Before attempting to connect or operate this product, please read these instructions completely Williams Electronics Ltd www.w-e.co.uk Tel: +44 (0)2921 660

More information

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010

ELECTRIC HOIST MODEL NO: CH2500B, CH4000B OPERATION & MAINTENANCE INSTRUCTIONS PART NO: , LS1010 ELECTRIC HOIST MODEL NO: CH2500B, CH4000B PART NO: 7630386, 7630391 OPERATION & MAINTENANCE INSTRUCTIONS LS1010 INTRODUCTION Thank you for purchasing this CLARKE Electric Hoist. Before attempting to use

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

TRANSPONDER TERMINAL MANUAL. Version: July 2012

TRANSPONDER TERMINAL MANUAL. Version: July 2012 Version: July 2012 2 1.0 PRODUCT DESCRIPTION 3 1.1 ORDER CODE 3 1.2 DESCRIPTION 3 2.0 WARNING 4 2.1 SAFETY 4 3.0 INSTALLATION 5 3.1 IMPORTANT 5 3.2 DIAGRAM 6 3.3 INSTALLATION PROCEDURE 7 4.0 CONNECTIONS

More information

MODEL A OLD NORCROSS ROAD LAWRENCEVILLE, GA (770) TEL (770) FAX (877) TOLL FREE

MODEL A OLD NORCROSS ROAD LAWRENCEVILLE, GA (770) TEL (770) FAX (877) TOLL FREE USER MANUAL RAPID-ROLL DOOR OWNER S MANUAL MODEL 230 975-A OLD NORCROSS ROAD LAWRENCEVILLE, GA 30045 (770) 338-5000 TEL (770) 338-5034 FAX (877) 925-2468 TOLL FREE Part # 6410T0009 Architectural Drawing

More information

Recommended Scheduled Maintenance

Recommended Scheduled Maintenance 005-08-9 () Illustrerad stol Be-Ge 900 Recommended Scheduled Maintenance Daily Inspection: Inspections every,000 working hours: Inspect and perform, if necessary, the required maintenance according to

More information

1ZSC ABH en, Rev. 1. Motor-drive mechanisms, types BUE and BUL2 Maintenance guide

1ZSC ABH en, Rev. 1. Motor-drive mechanisms, types BUE and BUL2 Maintenance guide 1ZSC000498-ABH en, Rev. 1 Motor-drive mechanisms, types BUE and BUL2 Maintenance guide Original instruction The information provided in this document is intended to be general and does not cover all possible

More information

Transformer bushings, type GOH. Technical guide

Transformer bushings, type GOH. Technical guide Transformer bushings, type GOH Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required

More information

ROLL-A-GLIDE INSULATED ROLLER DOOR. Installation Instructions

ROLL-A-GLIDE INSULATED ROLLER DOOR. Installation Instructions ROLL-A-GLIDE INSULATED ROLLER DOOR Installation Instructions 1. Motor 13. Brush Strips 2. Axle Assembly 14. Curtain Assembly 3. Rigid Link Collars 15. Door Laths 4. Octagonal Plug End 16. Locking Caps

More information

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit

3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit 3M Cold Shrink QT-III Silicone Rubber 3/C Cabinet Mount Termination Kit With High-K Stress Relief For 3-Conductor Copper Tape Shield Cables with or without Ground Wires 7600-T-3RJS Series Instructions

More information

SUNTURA SOLAR TRACKER

SUNTURA SOLAR TRACKER WindyNation SUNTURA SOLAR TRACKER SOT-TRKS-NF User s Manual Page 1 of 10 WindyNation 08/09/2012 Table of Contents 1 Introduction... 3 1.1 Limited Warranty... 3 1.2 Restrictions... 3 1.3 Warranty Claims

More information

Better Productivity by Standstill and Low-speed Monitoring

Better Productivity by Standstill and Low-speed Monitoring Better Productivity by Standstill and Low-speed Monitoring Standstill Monitoring Reduces Extra Waiting Time During Work Problem When a hazardous part has a long inertia, door-lock control using an off-delay

More information

Northern Sales & Distribution Centre

Northern Sales & Distribution Centre User Manual Industrial Door Northern Sales & Distribution Centre The Door Centre, Discovery Park, Crossley Road, Stockport, SK4 5BW /indupart /indupart /indupart /company/indupart-ltd Foreword This user

More information

Air Compressor. Owner s Manual. Sonny's Enterprises, Inc Hiatus Road Tamarac, Florida v1

Air Compressor. Owner s Manual. Sonny's Enterprises, Inc Hiatus Road Tamarac, Florida v1 Owner s Manual Sonny's Enterprises, Inc. 5605 Hiatus Road Tamarac, Florida 33321 16v1 *Table of Contents* WARNING *SAFETY REQUIREMENTS* WARNING... 3 *INTRODUCTION*... 5 Product Specifications... 6 Optional

More information

LED Signal Towers. Pre-assembled and pre-cabled in different aperture to highlight the processes. Features/Unique selling proposition

LED Signal Towers. Pre-assembled and pre-cabled in different aperture to highlight the processes. Features/Unique selling proposition Pre-assembled and pre-cabled in different aperture to highlight the processes LED Signal Towers Modular and monolithic design are available. Patlite s extensive product range cover highly advanced LED

More information

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series 3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series For 3-Conductor Copper Tape Shield Cables without Ground Wires Instructions IEEE Std. No. 48 Class 1 Termination CAUTION Working

More information

SERVICE MANUAL ULTIMATE 200

SERVICE MANUAL ULTIMATE 200 SERVICE MANUAL ULTIMATE 200 This manual is for: 20 200-120 Ultimate 200 std. 120V 60 Hz 20 200-240 Ultimate 200 std. 240V 50 Hz 20 201-120 Ultimate 200 DMX 120V 60 Hz 20 201-240 Ultimate 200 DMX 240V 50

More information

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION 770 EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the

More information

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain

RollSeal 1733 County Road 68 Bremen, Alabama Part No Rev Owner s Manual RS-Divider Curtain 1. 2. 7 3. 4. RollSeal 1733 County Road 68 Bremen, Alabama 35033 256-287-7000 Part No 4801-5176 Rev 12-11-17 Owner s Manual RS-Divider Curtain Table of Contents 1 Warnings (Avertissements)... 3 2 Limited

More information

High performance door Albany RR300. ASSA ABLOY Entrance Systems

High performance door Albany RR300. ASSA ABLOY Entrance Systems High performance door RR300 ASSA ABLOY Entrance Systems RR300 Modular system allows custom configurations Fast opening and closing speed saves energy costs Space saving construction for almost unlimited

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (S-type TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Conversion tables for Magne products

Conversion tables for Magne products KUNGSBACKA, SWEDEN, APRIL 2018 Conversion tables for Magne products Older models of Magne cannot be ordered anymore. The tables below indicate which replacement products to choose in case of a new installation,

More information

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions Drive Unit e-drive1 Installation instructions 04/2014 English translation of the original German installation instructions Contents Foreword... 3 Availability... 3 Structural features in the text... 3

More information

WELDING POSITIONER S OPERATION MANUAL CWP40

WELDING POSITIONER S OPERATION MANUAL CWP40 WELDING POSITIONER S OPERATION MANUAL CWP40 Revision May 19 2015 Note: The information contained in this manual is intended to be accurate. However the manufacturer retain the rights to make changes in

More information

Thermal Overcurrent Circuit Breaker 3120-F...

Thermal Overcurrent Circuit Breaker 3120-F... Thermal Overcurrent Circuit Breaker 20-F... Description An extremely versatile range of rocker switch/thermal circuit breakers (Stype TO CBE to EN 6094 with trip free mechanism) offering the choice of

More information

Multi-Mover Charger for model L25

Multi-Mover Charger for model L25 Multi-Mover Charger for model L25 Important safety instruction. Keep these instructions. This manual contains important instructions for the safety of the user and the operation of the device. 1. SYMBOLS

More information

UltraSlim Mechanical Install & Owner s Manual

UltraSlim Mechanical Install & Owner s Manual PN: 6410T0020 Version C Rev: 5/01/2012 UltraSlim Mechanical Install & Owner s Manual Doors are Ultra-Tough, Ultra-Reliable, and Ultra-Affordable. ASSA ABLOY ENTRANCE SYSTEMS All Rights Reserved 975-A Old

More information

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN Loadbreak Connectors MN650015EN Effective December 2015 Supersedes S500-15-1 October 2013 COOPER POWER SERIES 200 A loadbreak junction 15 and 25 kv class installation instructions DISCLAIMER OF WARRANTIES

More information