NEW STINGER SYSTEM 1 INTRODUCTION Alstom Transport

Size: px
Start display at page:

Download "NEW STINGER SYSTEM 1 INTRODUCTION Alstom Transport"

Transcription

1 1 INTRODUCTION Alstom Transport NEW STINGER SYSTEM

2 SUMMARY 1. INTRODUCTION APPLICATION PURPOSE PRODUCT DESCRIPTION INSULATED CONDUCTOR RAIL SYSTEM FOR ENERGY SUPPLY SUPPORT HANGERS CONTACT RAILS RIGID JOINT CLAMPS FEEDER CLAMPS FIXED POINT HANGERS END CAP CURRENT COLLECTORS TROLLEY ON STEEL TRACK RAIL ELECTRICAL AND CONTROL PANEL WITH CABLES SOCKET FOR POWER TRANSMISSION TO THE VEHICLE AND RAPID SECURE LINK (ON DEMAND) TECHNICAL DATA MAINTENANCE INSTRUCTIONS INTRODUCTION Alstom Transport

3 1. INTRODUCTION The objective of this document is to provide a general description of the Stinger system and the relevant insulated conductor rail system for electrical power supply (installation recommendation). The following symbols and references are used in this manual to give instructions and warnings (cautions) of particular importance. These must always be strictly observed! NOTE: Refers to special information on how to use the equipment safely and efficiently. CAUTION: Warns of general dangers. Danger of injuries and damage to property. CAUTION: Warns of danger of electrical shock from live equipment. The operating instructions must always be kept at an on-site location near the Stinger System where they can be readily accessed. In addition to the operating instructions, general regulations regarding accident prevention and environmental protection are to be observed. Read the following assembly and maintenance instructions before starting the installation of the line. All personnel working on the conductor system should be correctly trained and authorized to operate on the energy supply system in compliance with relevant standards, regulations and laws. Furthermore only authorized and qualified maintenance personnel may work with the stinger system and conductor rail system and all personnel working has to able to recognize and avoid risks and possible dangers which may occur during operation. 2. APPLICATION PURPOSE Stinger systems serve as energy supply for rail vehicles as suburban and underground in depot and maintenance area separated from their main power supply (i.e. third rail or catenary). The power in these areas is supplied by current collector trolleys that can move on conductor rails fixed close to ceiling. The power received by a special cable over current collector trolleys is acquired to vehicle by proper sockets. This system is developed from inside applications. For the installation of the conductor rails and other working condition refer to following chapters. 3 INTRODUCTION Alstom Transport

4 3. PRODUCT DESCRIPTION The system is composed by different items grouped in the following sets: a) Insulated conductor rail system for energy supply b) Current collectors c) trolley on steel track rail d) Electrical and control panel with cables e) Socket for power transmission to the vehicle and rapid secure link (on demand) 4 PRODUCT DESCRIPTION Alstom Transport

5 3.1. INSULATED CONDUCTOR RAIL SYSTEM FOR ENERGY SUPPLY The insulated conductor rail ALINOX is a solution for the electric feeding of the Stinger system, suitable for load up to 1300 A. ALINOX is designed and realized in order to offer the best safety guarantees against accidental contact, according to the standard EN 60529, in particular the protection degree of housing is IP23. The conductor is made of aluminum and stainless steel and all bolts and nuts are in stainless steel. The system is available from 400 A up to 1300 A, and it could be used for power and control system. The range for admissible temperature for standard PVC insulating housing (addition of the ambient and the operating temperature) is -30 C +85 C, for the power of 900, 1100 and 1300 A is available NORYL insulating housing with maximum temperature up to 145 C. The insulated conductor rail system will be installed onto the existing support structure. The mechanical correct installation of the support arm must be checked before the start of conductor rail installation SUPPORT HANGERS The insulated conductor rail system will be installed onto the existing support structure. The mechanical correct installation of the support arm must be checked before the start of conductor rail installation. The support hangers have to be fixed to the respective iron brackets, which have been installed according to Pict. 1 where is shown the attachment to a I or H profile supporting beam, using two shaped plates, which position can be adjusted along the brackets, in order to fit it. This is only an example of installation, the system could be developed according to the requested layout. There are 2 types of support hanger : one for 750 V in DC and another for upper voltage composed with a fiberglass insulator up to 1500 V ( DC). Pict.1 (example of composition) Pict.2 The brackets have to be drilled keeping a minimum distance of 70 mm among the phases (when is a required a three phase system. The standard installation pitch of the brackets is 2 m maximum. Particular attention has to be paid during the installation of the brackets, fixing them to the wall or to the beam, in order to keep them as aligned as possible, to guarantee a straight and parallel run of contact rails CONTACT RAILS The rails are supplied in standard pieces 4 m or 6m long (according to the load); they must be assembled placing them side by side horizontally (at a minimum distance of 70 mm among them), hooking them on one side in the support hanger (pict 2) and then turning them in the support hanger until they are also attached to the other side. Another method of assembly consists on inserting the bar into the front of the support hanger. Then you have to slide the rail along, until it joins to the adjacent conductor rail. 5 PRODUCT DESCRIPTION Alstom Transport

6 Important Remark: the distance between each joint of one rail to the next, and the closest support hanger must always be 300 mm. In this way, being the support hangers mounted with pitch 2 m and being the rail 4 m long, the joints between two sections will be always 300 mm away respect to the support hangers. Pict RIGID JOINT CLAMPS Pict.3 Before mounting the joint clamp on the line do the following operations: Brush with a metal (stainless steel) brush the contact surfaces of the joint clamp and contact rail. Apply a thin layer of white vaseline on the front surface of the contact rail or joint clamp The joint clamps are supplied in polythene bags containing the electric joint clamp, the insulating joint cover box. The electrical connecting clamp is composed of one stainless steel plate and an aluminium component assembled with 4 M10 screws, nuts, complete with washers (pict 3). Fit the clamp to the rail, space lightly the extremities of the rails and insert the upper part of the conductor between stainless steel plate and the aluminium component; move the other contact rail inserting the extremity as mentioned before and then tighten the 4 nuts taking care to centre the joint clamp (recommended torque 20 Nm). During the assembling phase make sure that the lower parts of the conductors are perfectly aligned and not twisted each other as shown in pict. 4 in order to avoid the outcome of the contact shoe due to the stumbling or bouncing over the joint passage. In case this happens, you have to align the extremities, with the help of two pliers positioned on the extremities and rotating them, one in the opposite sense of the other. 6 PRODUCT DESCRIPTION Alstom Transport

7 NO Pict.4 Remarks: in the unlikely case of presence of burrs near the extremities of the conductor, you must remove them before mounting the terminal, in order to avoid any irregular wear of the contact shoes. Then mount the two click half boxes that cover the joints as shown in the following photos PRODUCT DESCRIPTION Alstom Transport

8 FEEDER CLAMPS Pict.5 The feeder clamp must be installed where indicated in the installation diagram in substitution of a Joint Clamp. Before mounting the feeder clamp on the line do the following operations: Brush with a metal (stainless steel) brush the contact surfaces of the feeder clamp and contact rail. Apply a thin layer of white Vaseline on the front surface of the contact rail or feeder clamp. The feeder clamps are supplied in a polythene bag containing the electric feeder clamp, composed by a feeding plate, rigid joint clamp and related plate), two half-boxes with the relevant coupling self-tapping screws and four conical cable glands. The feeder clamps are realized with two components that have 4 holes for M10 screws in the lower part to be fixed to the conductor rail and 4 threaded holes M12 in the centre to link the feeder terminal. To assembly the clamp to the rail, slightly separate the extremities of the rails and insert the upper part of the conductor between the stainless steel plate and the aluminium component (pict. 5); move the other contact rail inserting the extremity as mentioned before and then tighten the 4 nuts taking care to centre the joint clamp. (Recommended torque 20 Nm). Cut the cone of the cable gland so that its diameter is slightly lower than the outer diameter of the cable; insert the extremity of the cable into the cable gland, connect the terminal connector at the extremity of the cable and then fix the terminal connector to the feeder clamp with the M12 screw (Recommended torque 40 Nm). Remove from one side, through a cutter, the round part of cable wall of the two half-boxes, on the side where the cable will be inserted; fit the cable together with cable gland between the two insulating half-boxes and then fix them one to the other through five self-threading screws. 8 PRODUCT DESCRIPTION Alstom Transport

9 FIXED POINT HANGERS Pict.6 They are used to determine a fixed point on the line. They must be mounted between two expansion joints or between an expansion joint and the extremity of the line. In case of lines for which expansion joints are not necessary, it will be enough to install one fixed point hanger per phase in the middle of the line. The fixed point hangers are similar to the support hangers, but they are equipped with a couple of half-joint (Pict.6) END CAP The end caps are threaded on the contact rail at the extremity of the line. 9 PRODUCT DESCRIPTION Alstom Transport

10 3.2. CURRENT COLLECTORS The current collector is fixed to the brackets, realized with steel profiles 60x60x6. (pict.7). When you install the brackets on the IPE, you have to respect the distance of 220 mm between the support surface of the base of the current collector and the sliding surface of the contact shoe. Besides you have to do all the possible so that the axis of the fixing hole of the current collector is aligned with the fixing one of the support hanger of the overhanging line. (pict. 8). The contact shoe is then inserted into the two lower nibs of the insulated profile of the contact rail, which act as a guide. The derivation cable from the current collector (excluded from our supply, maximum section 25 mmq) is connected directly to the shoe, inserting it into one of the two lateral holes you find on the insulating cover containing the shoe. The insulating cap, already mounted, closes the other hole. REMARKS: the cable must have an abundant loop and be fixed to the lower arm of the current collector, by means of a hose clamp, to avoid limitations of the articulations of the contact shoe and consequently possible bad contacts on the conductor (pict. 9). Pict.7 10 PRODUCT DESCRIPTION Alstom Transport

11 Pict.8 Pict.9 11 PRODUCT DESCRIPTION Alstom Transport

12 3.3. TROLLEY ON STEEL TRACK RAIL The system is supported by means trolley that runs upon the structural beam. The operators is able to pull up the system by means rope in order to reach easily the exact connection point with the vehicle in maintenance area. The leading trolley is realized in order to ensure the maximum handling capacity motion on steel track rail without incurring in such problems of wear of the wheels having frequent maintenance activities as consequence. Warning: if the system is equipped with rapid secure link, is forbidden to fix the pull rope to the vehicle to be driven during train movement within maintenance area. In this way the rapid secure link is by passed! 12 PRODUCT DESCRIPTION Alstom Transport

13 Main characteristics: Weight : very light system thanks to usage of light materials for construction Anti-jump wheel : to increase the stability of the trolley during the motion on the beam Dumper : one on each side of a trolley to absorb the impact between two adjacent Stinger System 13 Alstom Transport

14 Contrast wheels : to increase the lateral stability during the motion along the beam Fast Installation : simplicity of installation thanks to the marks on the transverse beam 14 Main characteristics: Alstom Transport

15 Weld less : no welding to reduce the weight, increase the resistance and decrease the cost Expandability : possibility to add Signal Rails or Power Rails even on Stinger System already installed 15 Main characteristics: Alstom Transport

16 3.4. ELECTRICAL AND CONTROL PANEL WITH CABLES The product provides the relevant command and control of Stinger System in a selective mode. Each Stinger belonging to the same feeding line can be switched ON or switched "OFF" depending of operating needs. PENDANT REMOTE CONTROL DESCRIPTION: The operators using the pendant remote control above is able to activate or deactivate such system according to the following state condition: 1. Key security switch on remote control : ON 2. Rapid secure link connected (if equipped) 3. Jupiter plug connected to the vehicle 4. Green Light on control panel switch ON automatically If all the above states are satisfied, the system is in Stand-by state and the operator can push the Green button on remote control to switch ON the System. 16 Main characteristics: Alstom Transport

17 ** Is enough just one condition didn't satisfied than the state above mentioned to get Inhibit state of the system Just after green button pushed the system goes in Working on state: 5. Green Light on control panel switch OFF automatically 6. Red light on remote control and control panel switch ON automatically (redundant light signalization) 7. The buzzer is activated automatically for 5 seconds then is stop. By the Working on state the system can returns in the state: 1. Stand by 1a:If the operator push the red button on remote control (Operating condition) 2. Inhibit 2a. if the operator switch off the key on remote control (Operating condition) 2b: if the rapid secure link is disconnecting (Emergency condition) 2c: if the Jupiter plug is disconnected from the vehicle (working condition not foresee) Especially relating to the case 2b, the system is able to actuate a protection in order to interrupt the voltage supply just one instant after the mechanical plugs disconnecting avoiding electric arc and potential injury to the operators. We precise that the case 2c is not a contemplated case over the normal activities of the Operators under High voltage presence. The system even in this case actuates the interruption of Voltage supply. take note that all the protections actuated by the system are simply a primary protection to mitigate all the potential risk of device damaging or injury prevention, Under no circumstances, those protections shall be considered exhaustive to avoid damages to the things or to the worker especially if the workers doesn t respect the right working instruction. 17 Main characteristics: Alstom Transport

18 To restore Inhibit state from Emergency condition cases 2b-2c, the Operator shall: 3. Turn the Key switch on remote control in position OFF 4. Push the button Red stop on remote control 5. The presence of green light on panel control ON 6. The absence of red light on Panel control and remote control OFF 7. Re connect the rapid secure link or Jupiter plug 8. Please refers to the table here after for component localization and summary working operation: key block button ON button OFF red lamp type green lamp rapid secure link jup iter/shunt regolable buzzer line Contactor control power supply plug interface location remote control remote control remote control remote control + control panel control panel frangible link plug vehicle plug interface control panel control panel control panel vehicle plug interface function without key inserted is not possible to close negative loop circuit of power control -system disabled button pushed in ON - system enable = Key inserted and in position = 1; button pushed in OFF -System interruption - all position of the key HV presence, red light visible directly on remote control by the operator, light on when the KL1 is powered HV absence, green light visible on cabinet, when the KL1 is open and p1 not pushed - pilot pin of frangible, close the negative loop when the frangible plug is completly inserted shunt of jupiter plug metro side, close the negative loop when the movable plug is inserted HV presence, regolable buzzer intermitted sound for 5 seconds, buzzer on when the KL1 is powered power line contactor drived by the logical condition, control unit low voltage power line 48Vdc plug Metro interface 3.5. SOCKET FOR POWER TRANSMISSION TO THE VEHICLE AND RAPID SECURE LINK (ON DEMAND) The socket or plug interface with the vehicle is typically defined by Client or Train integrator who define the type and relevant characteristics. This plug permits the distribution of power supply directly to the vehicle interlocked into a dedicated socket installed from Vehicle side. Please refers to the chapter Technical data hereby about plug characteristics for project. RAPID SECURE LINK (If equipeed) 18 Main characteristics: Alstom Transport

19 1 The Stinger System is equipped with a secure rapid link for the case of an emergency. If the rail vehicle moves out of the maintenance area, the connection cable is separated at secure link (1), before a high traction force causes a major damage on the Stinger System. If traction force exceeds a certain limit please refer to the Technical data chapter, the secure rapid link disconnects at first the control circuit and then, after a short time, the energy line. This measure prevents building up an electric arc, which can injure personnel. Then both Stinger Systems in the road will be switched OFF. Please refers to the chapter 3.4 to restore Inhibit state ** The Operators mustn t removed, during the normal maintenance activities under High Voltage the rapid secure link or Jupiter plug! 19 Main characteristics: Alstom Transport

20 4. TECHNICAL DATA Conductor rail Power conductor rail: Number of conductors: Voltage: Continuous rating: 500 A *Control conductor rail: Number of conductors: *Voltage: Continuous rating: Insulating material Protection: Direct contact protection Type Alinox (Al stainless steel) Possibility of different layout 750 VDC 1500 Vdc range 400 A 1300 A Type Alinox (Al stainless steel) Possibility of different layout 24 VDC 110 Vdc ; 48Vac 120 Vac 50hz up to 5,2 A PVC or NORYL -CEI EN IP23 EN60529 *The system can produce itself the Voltage to supply Control unit directly from the Power conductor line Collector trolley (including control panel) Collector trolley: hot dip galvanized steel Number of trolleys: 1 Current collectors: 2x 200 A (double collector) for power Number of current collectors: 1 per trolley, possibility of different lay-out Control collectors: 2x 100 A (double collector) for control Number of current collectors: 1 per trolley possibility of different lay-out Voltage: 750 VDC Continuous rating: 300 A per trolley Indication lights: Green Red, Yellow not used, Buzzer (timing adjustable) Weight Control Panel including trolley (Without cables): 30kg Electrical Diagram Cariboni Dwg xxxxx Towing speed: 1.1 m/s (max.) Pull force: 25N? (EHS compliant) Protection: IP 54 Normative: please refers to the electrical diagram of the system Control pendant Pushbuttons: Indicator lamps: Protection: Start Green; Stop Red, security Key switch Red Voltage presence IP65 20 TECHNICAL DATA Alstom Transport

21 Connection cable Cable type: Ultra flexible unipolar cable 120mm^2 Insulation material: class 5 Number of strands and cross section energy: 4 x 25 mm² Number of strands and cross section control: 2 x 16 mm² Diameter: 23,5 mm Cable length: 8 meter Rapid secure Link Type: Mechanical disconnecting including early Voltage break Connectors Release traction force: 35-40N Material shear rod: xx Length of buffer cable loop: xx Protection: IP55 Vehicle connector Type: FICHE PAT 2621 Souriau (depending of Customer/Train requirement) Park receptacle Type: RECR2621 Souriau (depending of Customer/Train requirement) Environmental conditions Temperature: +3 C to +48 C Humidity: 59% to 90% 21 MAINTENANCE INSTRUCTIONS Alstom Transport

22 5. MAINTENANCE INSTRUCTIONS a) Insulated conductor rail system for energy supply b) Current collectors Remember to check the recommended torque, reported in this table: Screw/nut Torque Nm M6 8 M8 12 M10 20 M12 40 In order to verify that there are no mistakes in connecting the cables of the power terminals we suggest to check the sequence of the phases. After the installation it is advisable to check the insulation resistance, in order to verify that there aren t components damaged during assembly. MAINTENANCE PROGRAM TO GUARANTEE THE BEST WORKING CONDITIONS WHAT WHEN HOW TO DO CHECKING OF THE WEAR OF THE CONTACT SHOES CHECKING OF THE PRESSURE OF THE CONTACT SHOE CLEANING OF THE SECTIONALIZING JOINTS CHECKING IF THE RAIL EASILY SLIDES INTO THE SUPPORT HANGERS CHECKING OF THE TIGHTENING OF THE FIXING SCREWS OF THE CURRENT COLLECTOR TO THE BRACKET CHECKING OF THE OPENING OF THE EXPANSION JOINT TEST OF THE SLIDING OF THE EXPANSION JOINTS CHECKING OF THE TIGHTENING OF THE JOINT AND FEEDER CLAMPS CHECKING OF THE TIGHTENING OF THE FIXING SCREWS OF THE SUPPORT HANGERS QUARTERLY HALF YEARLY YEARLY SEE POINT "A" SEE POINT "B" SEE POINT "C" SEE POINT "D" SEE POINT "E" SEE POINT "F" SEE POINT "G" SEE POINT "E" SEE POINT "E" A. CONTACT SHOES The contact shoes have to be replaced when the wear has reached the replacing line engraved on one side of the contact shoe. The replacement is made unscrewing the two screws, which tighten the two parts of the insulating shoe-holder, unscrewing the screw, which fixes the cable to the shoe; then remove the worn-out contact shoe and insert the new one as shown in the previous point. B. SPRINGS OF THE CURRENT COLLECTORS The springs have to be replaced when the pressure in working conditions is lower than 2 Kg. C. PERIODIC CLEANING OF THE LINE Remove eventual deposits of dust, grease or other, that may be present on the insulating housing of the rail, the support hangers or the current collectors, which could reduce the insulation distances. D. PERIODIC CLEANING OF THE SLIDING AREAS Remove eventual deposits of dust, grease or other, that may be present on the insulating housing of the rail, which could prevent the free sliding of the rail into the support hangers during the expansion; the same for the contact shoe sliding area. E. TIGHTENING OF THE SCREWS Check the tightening of the various screws by a dynamometric wrench rated to the suggested values (M10 20Nm, M12 40 Nm ) 22 MAINTENANCE INSTRUCTIONS Alstom Transport

1 Product Description System Layout Safety Instructions Intended Use Installation... 3

1 Product Description System Layout Safety Instructions Intended Use Installation... 3 Order Number 0812xx- Contents 1 Product Description... 2 2 System Layout... 2 3 Safety Instructions... 3 4 Intended Use... 3 5 Installation... 3 5.1 Hanger Clamp... 3 5.2 Cutting of Conductor Rail... 4

More information

ALINOX INSULATED CONDUCTOR RAIL FOR ELECTRICAL FEEDING OF CRANES

ALINOX INSULATED CONDUCTOR RAIL FOR ELECTRICAL FEEDING OF CRANES ALINOX INSULATED CONDUCTOR RAIL FOR ELECTRICAL FEEDING OF CRANES 2 ALINOX INSULATED CONDUCTOR RAIL Features, advantages and benefit The insulated conductor rail system ALINOX is the most suitable solution

More information

1 Product Description System Layout Safety Instructions Intended Use Installation... 3

1 Product Description System Layout Safety Instructions Intended Use Installation... 3 Part Number 0812xx- Contents 1 Product Description... 2 2 System Layout... 2 3 Safety Instructions... 3 4 Intended Use... 3 5 Installation... 3 5.1 Hanger Clamp... 3 5.2 Cutting of Conductor Rail... 4

More information

1 Product Description Check of the supplied Parts Notes Intended Use Current Collector... 3

1 Product Description Check of the supplied Parts Notes Intended Use Current Collector... 3 Order number 0813xx-... Contents 1 Product Description... 2 2 Check of the supplied Parts... 2 3 Notes... 2 4 Intended Use... 2 5 Current Collector... 3 6 Installation Sequence... 3 7 Pickup Guide... 7

More information

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the 770

More information

Conductor Bar Series 812

Conductor Bar Series 812 Conductor Bar Series 812 Contents Page 1 Completeness of the delivered parts... 1 2 Hints... 2 3 Installation... 2 4 Maintenance... 6 5 Photos of relevant system parts... 8 In addition to other advantages,

More information

INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3. Operating Instructions for DORNIER looms. Robustness Reliability Quality Productivity Versatility

INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3. Operating Instructions for DORNIER looms. Robustness Reliability Quality Productivity Versatility INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3 Operating Instructions for DORNIER looms Robustness Reliability Quality Productivity Versatility WARNING! - Condensation could form on the Weft Feeder when

More information

1 Product Description Check of the supplied Parts Notes Intended Use Current Collector... 3

1 Product Description Check of the supplied Parts Notes Intended Use Current Collector... 3 Part number 0813xx-... Contents 1 Product Description... 2 2 Check of the supplied Parts... 2 3 Notes... 2 4 Intended Use... 2 5 Current Collector... 3 6 Installation Sequence... 3 7 Pickup Guide... 6

More information

GTS-L4 5 / 10 / 15 TECHNICAL DATA

GTS-L4 5 / 10 / 15 TECHNICAL DATA GTS-L4 5 / 0 / 5 POWER SOLID STATE RELAYS WITH FOUR INDEPENDENT SOLID STATE RELAYS Main applications Extrusion lines and injection presses for plastics Hot channels Thermoforming machines Packing and packaging

More information

)LUHQ]H installation manual

)LUHQ]H installation manual installation manual All information contained in this document was provided by the manufacturer of the components for this model. As a fabricator, Retractableawnings.com claims no liability with respect

More information

MR - MEDIUM RATING A

MR - MEDIUM RATING A 88 MR - MEDIUM RATING 160-1000A SECTION CONTENTS 90 General features 96 Advantages 100 Illustrated contents MR MEDIUM RATING 102 Trunking components 110 Feed units and end covers 113 Tap-off boxes 118

More information

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrical Safety Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due to electrical shock) Electrical shock

More information

ATM Lighting sp. z o.o

ATM Lighting sp. z o.o INSTALLATION AND MAINTENANCE MANUAL FOR LUMINAIRE INS240 Carefully read the instructions before mounting the luminaire. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk, tel: +48 58 347 51 07,

More information

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016 SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016 3009/16 en Ed.02.2016 Read these Operating Instructions before performing any transportation, installation, commissioning, maintenance or

More information

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION 770 EC MACHINE DIRECTIVE COMPLIANCE DECLARATION (DIRECTIVE 89/392 EEC, APPENDIX II, PART B) Manufacturer: FAAC S.p.A. Address: Via Benini, 1 40069 - Zola Predosa BOLOGNA - ITALY Hereby declares that: the

More information

Quality touch! Pushbuttons and selector switches. Ø22mm QUICK AND EASY ACTUATOR INSTALLATION. Click! Click!

Quality touch! Pushbuttons and selector switches. Ø22mm QUICK AND EASY ACTUATOR INSTALLATION. Click! Click! Pushbuttons and selector switches Ø22mm Quality touch! QUICK AND EASY ACTUATOR INSTALLATION Click! Click! - Actuator fixing on the mounting surface, through a Ø22mm drilled hole, is obtained using its

More information

4 pole insulated conductor rails UNILIFT-ULA 35A, 50A, 80A, 100A

4 pole insulated conductor rails UNILIFT-ULA 35A, 50A, 80A, 100A 2 Table of contents General information... 4 Elements of the conductor rail supply line... 4 Innovative connection method... 5 Technical properties... 6 Construction of the line section... 6 Line section...

More information

Sectional and Tilting Door Opener

Sectional and Tilting Door Opener Sectional and Tilting Door Opener Installation Instructions and User Guide 600 800 1000 S/N WARNING Please read the manual carefully before installation and use. The installation of your new door opener

More information

Triple Output Power Supply

Triple Output Power Supply Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com Model 1672, 1673 Triple Output Power Supply INSTRUCTION MANUAL 1 Safety Summary The following safety precautions

More information

Technical Documentation

Technical Documentation Technical Documentation Product manual Holding brake controller Document: 0198441113316 Edition: V1.00, 03.2006 Important information The drive systems described here are products for general use that

More information

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2 OPERATING AND MAINTENANCE MANUAL Product: Type: Primary Current Injection Test Set 750ADM mk2 750ADM-H mk2 DESIGNED AND MANUFACTURED BY: T & R Test Equipment Limited 15-16 Woodbridge Meadows, Guildford,

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because

More information

RAFIX 22 QR. General data. Content

RAFIX 22 QR. General data. Content QR General data QR control component range For a mounting hole diameter of.3 mm to IEC 60947 50V/10A max. Water-jet proof IP65 collar shapes The lamps of the pushbuttons can also be replaced from the front

More information

Motor-drive mechanism, type BUL. Technical guide

Motor-drive mechanism, type BUL. Technical guide Motor-drive mechanism, type BUL Technical guide This Technical Guide has been produced to allow transformer manufacturers, and their designers and engineers, access to all the technical information required

More information

The specified data apply only if actuators/signal indicators are combined with contact blocks and lamp sockets within the same product range.

The specified data apply only if actuators/signal indicators are combined with contact blocks and lamp sockets within the same product range. General data QR control component range For a mounting hole diameter of.3 mm to IEC 60947 50V/10A max. Water-jet proof IP65 collar shapes The lamps of the pushbuttons can also be replaced from the front

More information

LB - LIGHTING BUSWAY 25-40A

LB - LIGHTING BUSWAY 25-40A 16 LB - LIGHTING BUSWAY 25-40A LIGHTING BUSWAY SECTION CONTENTS 18 General features 24 Trunking components: 2 and 4 conductors elements 28 Trunking components: 6 conductors elements 30 Plugs 33 Fixing

More information

Installation Manual. stairlift. A 4724 Neukirchen/W, Salling 8 Tel: 07278/ , Fax: 07278/ Mobil: 0664/

Installation Manual. stairlift. A 4724 Neukirchen/W, Salling 8 Tel: 07278/ , Fax: 07278/ Mobil: 0664/ Installation Manual Ω MEGA stairlift A 4724 Neukirchen/W, Salling 8 Tel: 07278/3514-15, Fax: 07278/3514-12 Email: office.lehner@gmx.at Mobil: 0664/1612980 CONTENTS OBSERVE THE FOLLOWING POINTS BEFORE INSTALLATION!...

More information

TECHNICAL MANUAL GTB16N

TECHNICAL MANUAL GTB16N TECHNICAL MANUAL GTB16N 1/20 1. INTRODUCTION 1.1 Purpose 1.2 Before Service 1.3 Safety 1.3.1 Hazard Definitions 1.3.2 For Your Safety 1.4 Specifications & dimensions 1.5 Description 2. HYDRAULIC SYSTEM

More information

Pro-Ductor Insulated flat conductor bar for 4, 7 or 10 conductors

Pro-Ductor Insulated flat conductor bar for 4, 7 or 10 conductors Darwinstraat 10 NL 6718 XR Ede The Netherlands Flexible with energy! Phone +31 (0)342 403900 Fax +31 (0)342 403912 email info@akapp.com URL www.akapp.com Pro-Ductor Insulated flat conductor bar for 4,

More information

C-Rail Festoon track systems

C-Rail Festoon track systems C-Rail Festoon track systems & Hose carrying systems Application C-Rail festoon track systems are the ideal solution for carrying cables supplying power to many types of moving machinery using either flat

More information

ATM Lighting sp. z o.o

ATM Lighting sp. z o.o INSTALLATION AND MAINTENANCE MANUAL FOR LIGHT FITTING INX230LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk, tel: +48 58

More information

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV MEDIUM VOLTAGE MEDIUM VOLTAGE APPLICATION CE-B Metal Clad switchboards are designed for use in public and industrial distribution system up to 24kV for the operation and protection of lines, generators,

More information

GTS-L 5 / 10 / 15 POWER SOLID STATE RELAYS WITH LOGIC CONTROL TECHNICAL DATA

GTS-L 5 / 10 / 15 POWER SOLID STATE RELAYS WITH LOGIC CONTROL TECHNICAL DATA GTS-L / 0 / POWER SOLID STATE RELAYS WITH LOGIC CONTROL Main applications Extrusion lines and injection presses for plastics Hot channels Thermoforming machines Packing and packaging machines Temperature

More information

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1 Webinar 1 Electrical 2 1 Webinar Introduction An average of one worker is electrocuted on the job every day There are four main types of electrical injuries: Electrocution (death due to electrical shock)

More information

MICRO WELD MODEL AUF-8 HEAVY DUTY FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL

MICRO WELD MODEL AUF-8 HEAVY DUTY FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL MICRO WELD MODEL AUF-8 HEAVY DUTY FERROUS BUTT WELDERS MICRO PRODUCTS COMPANY SERVICE MANUAL 1 TABLE OF CONTENTS 1.0 SPECIFICATIONS 2.0 GENERAL OPERATING INSTRUCTIONS 3.0 BASIC OPERATING PARTS 4.0 BASIC

More information

ATM Lighting sp. z o.o

ATM Lighting sp. z o.o INSTALLATION AND MAINTENANCE MANUAL FOR LUMINAIRE INS370 Carefully read the instructions before mounting the luminaire. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk, tel: +48 58 347 51 07,

More information

WORK BENCHES FOR ELECTRIC INSTALLATIONS. index

WORK BENCHES FOR ELECTRIC INSTALLATIONS. index index WORK BENCHES TWO PLACE WORK BENCH WITH 2 INDEPENDENT SUPPLIES DL 1101 FOUR PLACE WORK BENCH WITH 4 INDEPENDENT SUPPLIES DL 1103 FOUR PLACE WORK BENCH WITH 2 INDEPENDENT SUPPLIES DL 1104 TWO PLACE

More information

Aurora Wind Interface Box

Aurora Wind Interface Box Aurora Wind Interface Box Installation and Operator s Manual Page 2 of 15 REVISION TABLE Document Revision Author Date Change Description 1.0 T. Melzl 5/9/2006 First release of the document SAVE THESE

More information

Sectional and Tilting Door Opener Installation Instructions and User Guide

Sectional and Tilting Door Opener Installation Instructions and User Guide Sectional and Tilting Door Opener Installation Instructions and User Guide ET-600E ET-800E ET-1000E S/N WARNING Please read the manual carefully before installation and use. The installation of your new

More information

INSTALLATION M ANUAL

INSTALLATION M ANUAL INSTALLATION MANUAL Table of Contents UL Listings Installing the Warning Sign / Precautions Methods of Installation / Compact Installation Mounting the Secondary Entrapment / Welding Gate Arn Mounting

More information

CE DECLARATION OF MACHINE CONFORMITY

CE DECLARATION OF MACHINE CONFORMITY CE DECLARATION OF MACHINE CONFORMITY (DIRECTIVE 2006/42/EC) Manufacturer : Address: Declares that: FAAC S.p.A. Via Calari, 10-40069 Zola Predosa BOLOGNA - ITALY Operator mod. 541 3ph is built to be incorporated

More information

Northern Sales & Distribution Centre

Northern Sales & Distribution Centre User Manual Industrial Door Northern Sales & Distribution Centre The Door Centre, Discovery Park, Crossley Road, Stockport, SK4 5BW /indupart /indupart /indupart /company/indupart-ltd Foreword This user

More information

Quality Stainless Products DB-8000-XL Strut Compressor

Quality Stainless Products DB-8000-XL Strut Compressor Quality Stainless Products DB-8000-XL Strut Compressor Thank you for choosing Quality Stainless Products DB-8000-XL, Strut Compressor. In order to operate your new Strut Compressor safely, we suggest you

More information

PLP Compression Dead-end & Jumper Terminal for ACSR & ACSS Conductors

PLP Compression Dead-end & Jumper Terminal for ACSR & ACSS Conductors MARCH 2017 PLP Compression Dead-end & Jumper Terminal for ACSR & ACSS Conductors Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED

More information

Chapter 21 Practical Electricity

Chapter 21 Practical Electricity Chapter 21 Practical Electricity (A) Electrical Power 1. State four applications of the heating effect of electricity. Home: o Used in electric kettles o Used in electric irons o Used in water heaters

More information

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV CE - B36 - C - en - REV.00 2011.9 EDIU VOLTAGE EDIU VOLTAGE APPLICATION CE-B etal Clad switchboards are designed for use in public and industrial distribution system up to 36kV for the operation and protection

More information

ARACHNE 230V 24V- 12V

ARACHNE 230V 24V- 12V SWING GATES OPERATOR SERIE ARACHNE 12V-24V-220V INSTRUCTIONS MANUAL SAFETY Our compliments for your excellent choice. Your new electromechanical gear motor has been produced according to a high quality

More information

PATENT PENDING. Phone: (877) Operation and Service Manual

PATENT PENDING.   Phone: (877) Operation and Service Manual PATENT PENDING Phone: (877) 544-2291 Operation and Service Manual 2 IMPORTANT NOTICE This document contains information intended to aid in the proper installation, operation, and maintenance of the product

More information

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content 1. About this document Operating instructions.............pages 1 to 6 Original 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning

More information

TGI Vacuum Circuit-Breaker Air isolator Earthing switch

TGI Vacuum Circuit-Breaker Air isolator Earthing switch TGI Vacuum Circuit-Breaker Air isolator Earthing switch PATENT Versatile Visible isolation Simple Removable Index 3 in 1 2 Simple and versatile 4 Operations sequence ON Commissioning 8 Operations sequence

More information

VALIADIS S.A. HELLENIC MOTORS

VALIADIS S.A. HELLENIC MOTORS Explosion proof motors MAK 56-250 (MAKe 63-250) series Groups IIB and IIC Ex db / Ex db e (EPL) executions Gb or Ex tb IIIC (EPL) Db II 2 G, II 2D, 2GD SAFETY INSTRUCTIONS Safety Instructions MAK and MAKe

More information

GTZ 25 / 40 / 55. TECHNICAL DATA General features. Category of use: AC51, AC53a

GTZ 25 / 40 / 55. TECHNICAL DATA General features. Category of use: AC51, AC53a GTZ 25 / 40 / 55 THEE-PHASE SOLID STATE ELAYS WITH LOGIC CONTOL Vdc / Vac Main applications Thermoforming Plastic extrusion lines Industrial ovens and furnaces Heat treatments Control applications with

More information

K25000 & KD25000 Series

K25000 & KD25000 Series K25000 & KD25000 Series Fire Alarm Power Supplies Installation, Commissioning and Operating Manual Man-1128 Issue 14 January 2016 Man-1128_K25400_series_Power_Supply_Manual_14 Page 1 of 20 Section Page

More information

Power Connection Kit installation instructions

Power Connection Kit installation instructions Operating instructions & Parts Manual ET00 Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and

More information

SKY TRACK SYSTEM _ Intro

SKY TRACK SYSTEM _ Intro SKY TRACK SYSTEM _ Intro 82 lighting Ideal for all photo and video studios where the floor needs to be kept totally clear of power cables and lighting stands, the Sky Track System permits rapid manoeuvre

More information

ELECTRICAL. 60 Minutes

ELECTRICAL. 60 Minutes ELECTRICAL 60 Minutes AGENDA Electrical definitions Electrical shocks, burns and secondary injuries Electrical hazards in the workplace Safety devices and prevention steps Do s and Don ts INTRODUCTORY

More information

Instruction Manual for the. E-SL 450 Series

Instruction Manual for the. E-SL 450 Series Instruction Manual for the E-SL 450 Series Estate Slide Summary of Functions The Estate Slide is only to be used for vehicular Slide gates in a Class I setting. Class I: A vehicular gate opener (or system)

More information

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL INSTALLATION INSTRUCTIONS AND OPERATION MANUAL UL325-2010 Compliant Commercial and Industrial Door Operator Logic Control Continuous Duty IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk

More information

Assembly and Maintenance Manual Type ASNU

Assembly and Maintenance Manual Type ASNU Assembly and Maintenance Manual Type ASNU Hatschekstr.36 69126 Heidelberg Germany Tel +49(0)6221 30470 Fax +49(0)6221 304731 info@stieber.de www.stieber.de Date of issue: 30.05.2018 GB Revision: 0 U:\EngUsers\!ProduktDoku\1AAA_Einbauerklaerung_Wartungsanleitung_Konformitaetserklaerung\1AAA_Wartungsanleitungen\Orginal_Worddatei\_ASNU.docx

More information

ATM Lighting sp. z o.o

ATM Lighting sp. z o.o INSTALLATION AND MAINTENANCE MANUAL FOR LIGHT FITTING INV360LED Carefully read the instructions before mounting the light fitting. ATM Lighting sp. z o.o., ul. Budowlanych 31, 80-298 Gdańsk, tel: +48 58

More information

Operating Instructions

Operating Instructions Operating Instructions Pendant Light Fitting > Contents 1 Contents 1 Contents...2 2 General Information...2 3 General Notes Regarding Safety...3 4 Intended Area of Application...4 5 Technical Data...5

More information

Series Type ROi400 DE EN FR. Montage- und Betriebsanleitung Installation and operating instructions Instructions de montage et d utilisation

Series Type ROi400 DE EN FR. Montage- und Betriebsanleitung Installation and operating instructions Instructions de montage et d utilisation Montage- und Betriebsanleitung Installation and operating instructions Instructions de montage et d utilisation DE EN FR Member of JOST-World Modellreihe Series Type ROi400 Vollautomatische Anhängekupplung

More information

USER'S GUIDE and Spare Parts Drawings GENERIC APPLICATIONS

USER'S GUIDE and Spare Parts Drawings GENERIC APPLICATIONS Super ELF-X2 USER'S GUIDE and Spare Parts Drawings GENERIC APPLICATIONS SUPER ELF X2 WARNING! - Condensation could form on the Weft Feeder when it is moved from the cold environment of the warehouse to

More information

Bowl feeder WV401-1 / Translation of operating and installation instructions

Bowl feeder WV401-1 / Translation of operating and installation instructions Bowl feeder WV401-1 / 402-1 Translation of operating and installation instructions Copyright by Afag GmbH This operation instruction applies to: Bowl feeder WV401-1 Bowl feeder WV402-1 Type 230 V / 50

More information

DR-6C MEDIUM VOLTAGE SWITCHGEAR COMPACT RING MAIN UNIT. Installation Manual: DR-6C / DR-6+ C

DR-6C MEDIUM VOLTAGE SWITCHGEAR COMPACT RING MAIN UNIT. Installation Manual: DR-6C / DR-6+ C DR-6C MEDIUM VOLTAGE SWITCHGEAR COMPACT RING MAIN UNIT Installation Manual: DR-6C / DR-6+ C SGC - SwitchGear Company nv - Moorstraat 24 - B-9850 Nevele - Belgium +32 (0)9/321.91.12 - Fax +32 (0)9/321.91.13

More information

20 Gauge Super-Speed. shoprpmachine

20 Gauge Super-Speed. shoprpmachine Operator tor s s manual 20 Gauge Super-Speed 1 WARRANTY Our guarantee on the products we manufacture is limited to repair or replacement without charge, of any part found to be defective in materials or

More information

4-Ductor Insulated conductor bar

4-Ductor Insulated conductor bar Darwinstraat 10 4-Ductor AKAPP 4-Ductor current supply system compact, reliable and safe! AKAPP 4-Ductor is a compact, reliable and safe current supply system for cranes, hoists, monorail systems, conveyor

More information

Owner s Manual. ELECTRIC WIRE ROPE HOIST and TROLLEY RH SERIES

Owner s Manual. ELECTRIC WIRE ROPE HOIST and TROLLEY RH SERIES EFFECTIVE: September 25, 2007 Owner s Manual ELECTRIC WIRE ROPE HOIST and TROLLEY RH SERIES 2 Ton through 20 Ton Capacity Product Code and Serial Number WARNING This equipment should not be installed,

More information

Arm - RX series 170B family

Arm - RX series 170B family Arm - RX series 170B family Characteristics Stäubli Faverges 2004 D18325304B - 11/2004 The specifications contained in the present document can be modified without notice. Although all necessary precautions

More information

User Manual. Important notes:

User Manual. Important notes: User Manual Important notes: The Magnic Light system is intended only for installation with original Magnic Light adapters as additional lighting system (not as a sole source of light!) according to the

More information

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0 Products Tde Macno User s Manual BRAKING UNIT Cod. MP00401E00 V_1.0 SUMMARY 1 GENERAL DESCRIPTION... 2 2 USE LIMITATIONS... 2 2.1 Climatic Class... 2 2.2 Resistance To Chemically Active Substances...

More information

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

F ERNI K I T THE FERNI-S KIT CONSISTS OF: CAME UNITED KINGDOM LTD ORCHARD PARK INDUSTRIAL ESTATE TOWN STREET, SANDIACRE, NOTTINGHAM, NG10 5BP TEL: 0115 921 0430 FAX: 0115 921 0431 INTERNET - www.cameuk.com E-MAIL - enquiries@cameuk.com TECHNICAL

More information

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY OPERATING INSTRUCTIONS PLEASE READ CAREFULLY 925-0330 Rev 0 0416 TABLE OF CONTENTS SAFETY SUMMARY... 3 SPECIFICATIONS... 4 1.0 INTRODUCTION/DESCRIPTION.... 5 2.0 LOCATION AND MOUNTING... 5 3.0 CONNECTIONS

More information

SLIDING DOOR OPERATOR INSTRUCTION MANUAL

SLIDING DOOR OPERATOR INSTRUCTION MANUAL SLIDING DOOR OPERATOR INSTRUCTION MANUAL (MODEL NO. 1071.101 & 1071.102) Please carefully keep this manual for good maintenance. Caution Be sure the door opener is far away from moisture, vibration, and

More information

INSTALLATION INSTRUCTIONS SERVICE MANUAL

INSTALLATION INSTRUCTIONS SERVICE MANUAL INSTALLATION INSTRUCTIONS SERVICE MANUAL This manual provides instructions for the proper installation of the L 06 HAWLE stair lift. It is necessary to read and understand the contents of these instructions

More information

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE Comfort 800E/1000E WARNING Please read the manual carefully before installation and use. The installation of your new door opener

More information

Outdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety...

Outdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety... Contents 1 Introduction...1 2 Safety...4 3 Product Specifications...6 Outdoor UPS User Manual 4 Installation...8 4.1 Inspection...8 4.2 Installing the UPS Cabinet...8 4.3 Connecting the Power Supply...10

More information

Visit Our Our Our Web Site at:

Visit Our Our Our Web Site at: Visit Our Our Our Web Site at: ww w ww w w w w. l o c k f o rr r m e r r r. c o m 711 OGDEN AVENUE, LISLE, ILLINOIS 60532-1399 Phone (630) 964-8000 Fax (630) 964-5685 09-1998 Operator tor s manual 20 Gauge

More information

INSTALLATION, OPERATION AND MAINTENANCE TECHNICAL MANUAL

INSTALLATION, OPERATION AND MAINTENANCE TECHNICAL MANUAL ISO 9001:2008 Via Renata Bianchi, 12 16152 Genova ITALY Tel. +39.01.6017016 Fax. +39-010-601-6021 www.tecnidro.com s INDEX 1. Introduction 1.1 Premise 1.2 Generality 1.3 Principle of operation 2. INSTALLATION

More information

Electrobar Elite. Instruction Manual. Conductor Bar System. ELITE-03A October 2011 Part Number: R3 Copyright 2011 Electromotive Systems

Electrobar Elite. Instruction Manual. Conductor Bar System. ELITE-03A October 2011 Part Number: R3 Copyright 2011 Electromotive Systems Electrobar Elite Conductor Bar System Instruction Manual ELITE-03A October 2011 Part Number: 005-1054-R3 Copyright 2011 Electromotive Systems 2011 MAGNETEK All rights reserved. This notice applies to

More information

Exhaust Alert Installation & Operating Instructions THE SCIENCE OF SILENCE. Exhaust Alert Operating & Fitting Instructions 1

Exhaust Alert Installation & Operating Instructions THE SCIENCE OF SILENCE. Exhaust Alert Operating & Fitting Instructions 1 Exhaust Alert Installation & Operating Instructions THE SCIENCE OF SILENCE Exhaust Alert Operating & Fitting Instructions 1 Contents Exhaust Alert Fitting Instructions Section Page 1 Introduction 2 1.1

More information

Electronic basin tap or mixer with anti-legionella Rinse out Program. Automatic draining for 45 sec., each 24 hours after last use 230/12V.

Electronic basin tap or mixer with anti-legionella Rinse out Program. Automatic draining for 45 sec., each 24 hours after last use 230/12V. INSTALLATION INSTRUCTIONS Tempomatic & Binoptic 447500, 441157, 379ENC, 379MCH, 379ECM Date: Dec 2008 Electronic basin tap or mixer with anti-legionella Rinse out Program 230/12V. Automatic draining for

More information

Conductor Bar Series 831

Conductor Bar Series 831 Conductor Bar Series 831 1 MV0831-0021b-E CONDUCTOR BAR 831 MANUAL 1 1. Completeness of the delivered parts Please check first, if the individual parts are completely delivered (see Photos on page 7 and

More information

Instruction Manual LA-SDO1 Sectional garage door opener

Instruction Manual LA-SDO1 Sectional garage door opener Instruction Manual LA-SDO1 Sectional garage door opener INSTALLATION INSTRUCTIONS OWNERS COPY 1 WARNING: It is vital for the safety of persons to follow all instructions. Failure to comply with the installation

More information

Basic steps for installing the AmeriGlide Express Dumbwaiter

Basic steps for installing the AmeriGlide Express Dumbwaiter Basic steps for installing the AmeriGlide Express Dumbwaiter 1. Remove Shroud. 2. Mount lower section of Track and Unit to hoistway wall and Brackets. 3. Remove Shipping Bracket from Top of Car. 4. Install

More information

Installation Instructions. Ultimate Screen. English Version 2.3

Installation Instructions. Ultimate Screen. English Version 2.3 Installation Instructions Ultimate Screen English Version 2.3 REMARKS. This manual simply describes the rules governing use and installing of the Ultimate Screen Blind. For different versions we would

More information

APPLICATION NOTES VALVE CHECKER M

APPLICATION NOTES VALVE CHECKER M APPLICATION NOTES VALVE CHECKER M040-120-001 1 of 16 CONTENTS Chapter Title Page 1. Description 3 2. Specification 7 3. Connecting to valve and plant 8 4. Plant mode operation (in line) 9 5. Checker mode

More information

BELT CONVEYOR PNL/4 Series User and maintenance manual

BELT CONVEYOR PNL/4 Series User and maintenance manual BELT CONVEYOR PNL/4 Series User and maintenance manual 1 DECLARATION OF CONFORMITY CE In conformity with the 2006/42/CE Machine Directives, Enclosure II, section A The company: VIRGINIO NASTRI S.r.l. Tel.

More information

Typical Installation Schematic

Typical Installation Schematic The 760 Gate Automation System The FAAC 760 automation system consists of a monoblock hydraulic unit and foundation box assembly. The system is designed for underground installation, and will not alter

More information

BELT CONVEYOR CB/M5 Series

BELT CONVEYOR CB/M5 Series BELT CONVEYOR CB/M5 Series User and maintenance manual 1 DECLARATION OF CONFORMITY The company: Tel. +39-0444 450 620-451 520 Fax +39-0444 671 840 declares under its own responsibility that the machine

More information

Instruction manual. EK6 Earthing switch 36/40.5 kv

Instruction manual. EK6 Earthing switch 36/40.5 kv Instruction manual EK6 Earthing switch 36/40.5 kv Your safety first always! That s why our instruction manual begins with these recommendations: Only install switchgear and/or switchboards in enclosed

More information

COMPACT BUSWAY 40 & 60 AMP HOUSING

COMPACT BUSWAY 40 & 60 AMP HOUSING 40 & 60 AMP HOUSING B40 & HOUSING Each Track Busway housing section consists of an extruded aluminum housing with an insulated strip containing copper conductors mounted on the top interior wall. The aluminum

More information

Certified Quality System UNI EN ISO 9001 : 2008 SERVICE MANUAL PGRF series Release A10/14

Certified Quality System UNI EN ISO 9001 : 2008 SERVICE MANUAL PGRF series Release A10/14 312 Certified Quality System UNI EN ISO 9001 : 2008 www.comerindustries.com SERVICE MANUAL PGRF series Release A10/14 INDEX GENERAL INFORMATION... 3 GEARBOX UNIT IDENTIFICATION... 3 RISKS AND PRECAUTIONS...

More information

THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL. WELLS ENGINE UNIT 230 VOLT Product No. U905, U906, U907, U908

THIS PRODUCT IS FOR PROFESSIONAL LABORATORY USE ONLY USER'S MANUAL. WELLS ENGINE UNIT 230 VOLT Product No. U905, U906, U907, U908 DENTAL, INC. TECHNICAL BULLETIN U807-022510 5860 FLYNN CREEK ROAD READ ALL INSTRUCTIONS P.O. BOX 106 BEFORE PROCEEDING COMPTCHE, CALIFORNIA, U.S.A. 95427 SAVE THIS FOR FUTURE REFERENCE THIS PRODUCT IS

More information

Installation and Operating Instructions for EAS -NC clutch Type 45_. _. _ Sizes 02 and 03

Installation and Operating Instructions for EAS -NC clutch Type 45_. _. _ Sizes 02 and 03 Table of contents: Please read and observe this Operating Instruction carefully! A possible malfunction or failure of the clutch and any damage may be caused by not observing it. Page 1: - Table of contents

More information

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy INSTALLATION MANUAL FOR SWING SHUTTERS KAF212 FACE S.r.l. Viale delle Industrie, 74 31030 Dosson di Casier Treviso Italy INDEX Subject Page 1. General safety instruction 2 1.1 EC marking and European directives

More information

M MODEL FORK POSITIONERS

M MODEL FORK POSITIONERS Index: INTRODUCTION SPECIFICATIONS AND USE OF THE EQUIPMENT 1. RECOMMENDATIONS FOR USING THE EQUIPMENT 1.1 PROHIBITED MOVEMENTS 1.2 CORRECT MOVEMENTS 2. ATTACHMENT CONFIGURATION 3.INSTALLING THE POSITIONER

More information

J2 Remove sound insulation/knee guard 1 and side panel 2 on center console

J2 Remove sound insulation/knee guard 1 and side panel 2 on center console J1 Preparations Drive car forward on a level surface so that wheels are straight. Disconnect battery negative lead. Turn ignition key to position 1 so that steering lock is off. J2 Remove sound insulation/knee

More information

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL INSTALLATION INSTRUCTIONS AND OPERATION MANUAL NEMA 4X UL325-2010 Compliant Commercial and Industrial Door Operator Logic Control Continuous Duty IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the

More information

Pump Manual. Model Numbers: SP240VDFS57LPM SP240VDFS80LPM. Product Names: Digital Refueling Station - 57 L/min Digital Refueling Station - 80 L/min

Pump Manual. Model Numbers: SP240VDFS57LPM SP240VDFS80LPM. Product Names: Digital Refueling Station - 57 L/min Digital Refueling Station - 80 L/min Pump Manual Model Numbers: SP240VDFS57LPM SP240VDFS80LPM Product Names: Digital Refueling Station - 57 L/min Digital Refueling Station - 80 L/min Copyright: Scintex Fuel Depot 2012[Type text] Page 1 WARNING: