Contact Force (lb.) Stroke (in.) Fluid Advance Work Supports, hydraulic pressure lifts spring which lifts plunger, hydraulic pressure locks 0.

Size: px
Start display at page:

Download "Contact Force (lb.) Stroke (in.) Fluid Advance Work Supports, hydraulic pressure lifts spring which lifts plunger, hydraulic pressure locks 0."

Transcription

1 B-21 For Retracted Plunger Applications Available in three capacities 1,000, 2,500 and 4,000 lb. Normally retracted plungers do not interfere with part loading. them with hydraulic pressure, exerting only spring force to bring the plunger into contact with your part. Hydraulic pressure then automatically sequences, freezing the plunger properly against the part. Ventless configuration and built in wiper keeps chips and debris out, reducing the chance of plunger/sleeve sticking or binding. Stainless steel plunger and sleeve assemblies help guard against corrosion in most machining en vi ron ments. Standard SAE porting and alternate o-ring manifold face seal is located in the base of the support for bolt down in stal la tion. The base can be removed for direct cartridge mounting. U. S. Patent No. 5,957,443 Feeder caps (page B-25) and retaining collars (page L-1). Model No. Dimensions Capacity (lb.)* Mounting Style *** Contact Force (lb.) Stroke (in.) Base Dimensions (in.) Retracted Height (in.) Oil Capacity (cu. in.)** s, hydraulic pressure lifts spring which lifts plunger, hydraulic pressure locks Cartridge 1-6 N/A SAE/Manifold X 1.31 X Cartridge 3-10 N/A SAE/Manifold X 1.50 X Cartridge N/A SAE/Manifold 0.99 X 2.88 X * capacities are listed at 5,000 psi maximum operating pressure. capacities for other pressures must be determined by consulting the capacity graph on page B-22. ** Restrict flow rate to a maximum of 130 cu. in./minute. *** For cartridge mount models, see cavity dimensions on pages and B-24. NOTE: The maximum system backpressure a fluid advance work support can overcome is 10 psi. Returning backpressure greater than 10 psi may cause slow or failed retraction. Model No. A B C D E F G H J K L M N P s, hydraulic pressure lifts spring which lifts plunger, hydraulic pressure locks / / Vektek, February

2 B-22 All dimensions are in inches. SUPPORT FORCE (lb) SUPPORT FORCE (lb) 0 INPUT PRESSURE (psi) INPUT PRESSURE (psi) 5000 ILS REV E lb 1400 lb 2500 lb lb Model No. Model No. Model No. Model No ILS REV H For proper sealing, mating surface must be flat within in with a maximum 63 µ in.r a surface finish. Q R S T V W X Y Z AA AB AC AD AE s, hydraulic pressure lifts spring which lifts plunger, hydraulic pressure locks. 5/16-18 X SAE YES N/A 3/8-24 x /16-14 X SAE N/A N/A N/A N/A YES /2-13 X SAE N/A N/A N/A N/A YES Vektek, June 2017

3 Cartridges B-23 Cavity Check List Confirm capacity of item selected. Note the sealing surface finish requirements. Minimum depth specification represents the nominal depth of the standard Vektek base dimension. Confirm cavity drawing is appropriate for the model number used. Note specified thread depth when cutting threads. When using a bottoming tap tool, modifications may be required. When hand tapping threads, perpendicularity is essential. The 'fluid' passage is located in the center. Cartridge Dimensions Model No. A B C D E F G H J M V W, Oil Rise Cartridge /16-18 X /8-24 x / /16-4 X / /2-13 X Vektek, February

4 Cartridge Cavities B-24 For proper sealing, mating surface must be flat within in with a maximum 63 μ in. R a surface finish Vektek, February 2017

5 Accessories B-25 Shields Model No Fits Model No. A B C D For use with S/A fluid advance s only. Feeder Caps Model No. A B C D For use with fluid advance s only / / Machining Specifications For s Mounted with a Feeder Cap or Lock Nut Capacity (lb.) B C 1, , / , / Self-produced Contact Bolt Model No. Capacity (lb.), Oil Rise Std. Stroke Long Stroke 2500 Std. Stroke 2500 Long Stroke O-ring Part No. A B C D E (0.236 x 0.059) (0.301 x 0.064) (0.301 x 0.070) (0.301 x 0.070) (0.364 x 0.070) /16-18 UNC-2A /8-24 UNF-2A /16-14 UNC-2A /16-14 UNC-2A /2-13 UNC-2A Vektek, February

6 Features and Capacity Graphs Spring B-10 Air Standard Features Highly repeatable; plus or minus inches. Standard s may be bolted up or down to mount directly on fixture plates. They may also be installed through a hole in the fixture and locked in place using retaining collars for easy adjustment. Standard SAE porting is located in the base of the sup port for easy access to both the clamp and vent ports (bronze filter installed before shipping). Design features insure VektorFlo work supports last longer, stand up to harsh en vi ron ments and abuse bet ter than other models without these features. Proprietary wiper and seal de signs reduce con tam i na tion and drag for longer lasting, better per form ing work sup ports. Special corrosion resistant plungers and sleeves reduce the tendency to stick. Special large diameter plungers and sleeves provide greater rigidity. Cartridge mount work supports available in all styles for installation into customer machined cavities Vektek, February 2017

7 Vektek Concept Concept B-26 PRV Combo SEQ/PRV TuffCam Top Flange Swing Clamp SEQ/PRV Combo PRV Assembly TuffCam Top Flange Swing Clamp Hydraulic TuffCam Top Flange Swing Clamp Hydraulic Vektek, February 2017

TuffCam Swing Clamps C-1. Frequently Asked Questions

TuffCam Swing Clamps C-1. Frequently Asked Questions TuffCam s Frequently Asked Questions C-1 When do you recommend the use of TuffCam s over the standard product? Applications where speed is essential, massive arms are required, or position sensing is necessary,

More information

Cylinders. Standard Features F-1. Frequently Asked Questions, Features

Cylinders. Standard Features F-1. Frequently Asked Questions, Features Frequently Asked Questions, Features Why use Cylinders? Cylinders are the most common and least costly form of hydraulic clamping avail able. They can be sized adequately to allow you to clamp across or

More information

Accessory Valves. Frequently Asked Questions

Accessory Valves. Frequently Asked Questions Flow Control Frequently Asked Questions What is the difference between your Accessory Valves and others I already use? Vektek Accessory Valves are sized for the normal flows and conditions present in hydraulic

More information

TuffCam Swing Clamps C-1. Frequently Asked Questions

TuffCam Swing Clamps C-1. Frequently Asked Questions Frequently Asked Questions C-1 When do you recommend the use of TuffCam Swing Clamps over the standard product? Applications where speed is essential, massive arms are required, or position sensing is

More information

Push/Pull Cylinders G-1. Frequently Asked Questions. Frequently Asked Questions, Features

Push/Pull Cylinders G-1. Frequently Asked Questions. Frequently Asked Questions, Features Frequently Asked Questions, Features G-1 Frequently Asked Questions What is the intended application of these devices? They are intended for use actuating remote mechanisms, pulling on clamp plates, or

More information

Miscellaneous Plumbing

Miscellaneous Plumbing Manifolds Manifolds Four different styles to work in your par ticu lar system. SAE straight thread o-ring ports used exclusively to provide drip free hydraulic connections. High strength steel, careful

More information

NEW PRODUCTS PRECISION HYDRAULIC CLAMPING. Metric Slip-in Cartridge. 360 Link Clamp. Confirmation Valve

NEW PRODUCTS PRECISION HYDRAULIC CLAMPING. Metric Slip-in Cartridge. 360 Link Clamp. Confirmation Valve PRECISION HYDRAULIC CLAMPING NEW PRODUCTS sales@vektek.com www.vektek.com 800-992-0236 NEW PRODUCTS Metric Slip-in Cartridge 360 Link Clamp The BEST Link Clamp Innovation Ever... NOW AVAILABLE IN: INCH

More information

TuffCam 7 MPa Swing Clamps

TuffCam 7 MPa Swing Clamps TuffCam 7 MPa Swing Clamps Frequently Asked Questions C-1 When do you recommend the use of TuffCam 7 MPa Swing Clamps over other Vektek product? Sometimes there are applications where speed is essential.

More information

We shut the air supply down to our clamps once they are in position. Sometimes we notice that they are sticking. Could this be the cause?

We shut the air supply down to our clamps once they are in position. Sometimes we notice that they are sticking. Could this be the cause? Frequently Asked Questions B-1 Following are some of the questions we have been asked while developing the VektorAir TM line. Please read them carefully before planning your system. Many common problems

More information

Palletized Fixture Accessories

Palletized Fixture Accessories Frequently Asked Questions Some questions about pallet and tombstone clamping systems are common to both novices and experienced users. The answers to the following questions may help you better understand

More information

Directional Control Valves

Directional Control Valves Frequently sked Questions Frequently sked Questions What is the function of a directional control valve? directional control valve is the extend and retract control for your hydraulic cylinders. It provides

More information

VEKTEK PARTS LIST THIS IS A TWO PAGE PARTS LIST. THIS FIRST PAGE APPLIES TO MODEL AT REVISION C AND LATER REVISIONS.

VEKTEK PARTS LIST THIS IS A TWO PAGE PARTS LIST. THIS FIRST PAGE APPLIES TO MODEL AT REVISION C AND LATER REVISIONS. Copyright 986-208 209 by Vektek, Inc. 2 THIS IS A TWO PAGE PARTS LIST. THIS FIRST PAGE APPLIES TO MODEL 50-4085-00 AT REVISION C AND LATER REVISIONS. 2 2X APPLY LOW STRENGTH THREAD LOCKER TO THREADS. TIGHTEN

More information

VEKTEK PARTS LIST. Copyright by Vektek, Inc.

VEKTEK PARTS LIST. Copyright by Vektek, Inc. Copyright 986-208 by Vektek, Inc. 2 THIS IS A TWO PAGE PARTS LIST. THIS FIRST PAGE APPLIES TO MODELS 45-0485-00 & L5-0485-00 AT REVISION B AND LATER REVISIONS. 4 2 2X APPLY LOW STRENGTH THREAD LOCKER TO

More information

Series PVP Variable Volume Piston Pumps

Series PVP Variable Volume Piston Pumps Series PVP Variable Volume Piston Pumps Catalog HY28-2661-CD/US zp2 hpm12-1.p65, lw, jk 1 Notes Series PVP hpm12-1.p65, lw, jk 2 Introduction Series PVP Series Sizes 6-14 Phased Out For Reference Only

More information

Disc Valve Hydraulic Motors Series 4000

Disc Valve Hydraulic Motors Series 4000 Disc Valve Hydraulic Motors Series 0 10.20 inspired hydraulics. Änderungen und Druckfehler vorbehalten 10.20 EN EATON_Motoren english Highlights Features 10 displacements, a variety of mounting flanges

More information

Directional Control Valves

Directional Control Valves Frequently sked Questions N-1 Frequently sked Questions What is the function of a directional control valve? directional control valve is the extend and retract control for your hydraulic cylinders. It

More information

OPERATION AND PARTS MANUAL

OPERATION AND PARTS MANUAL OPERATION AND PARTS MANUAL MODEL NUMBER : PART NUMBER : TAP- IN KIT 5100-5151 BAYNE MACHINE WORKS, INC. PHONE: (864) 288-3877 910 FORK SHOALS ROAD TOLL FREE: (800) 535-2671 GREENVILLE S.C., 29605 FAX:

More information

Power Supplies. Hydraulic Oil ISO 32 Grade

Power Supplies. Hydraulic Oil ISO 32 Grade Frequently Asked Questions I have a pump on my machine. Can I use it to drive my clamps too? Yes, you may use a machine pump to drive your clamping system if it has the following characteristics: 1) It

More information

Fabri-Valve Push Through Slurry Valve SV1. Engineered Valves

Fabri-Valve Push Through Slurry Valve SV1. Engineered Valves Fabri-Valve Push Through Slurry Valve SV1 Engineered Valves Fabri-Valve SV1 - Push Through Slurry Valve The Fabri-Valve SV1 Push-Through Slurry Valve is one of the most versatile knife gate valve configurations

More information

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA Catalog HY28-6/NA PV, PVT Series Piston Pumps Variable Volume Catalog HY28-6/NA 1 Catalog HY28-6/NA Notes Series PV 2 Catalog HY28-6/NA Introduction Series PV Quick Reference Data Chart Pump Delivery Approx.

More information

Disc Valve Motors Integral Cross Over Relief Valve Technical Manual 2000 Series

Disc Valve Motors Integral Cross Over Relief Valve Technical Manual 2000 Series Disc Valve Motors Integral Technical Manual 2000 Series Introduction Eaton Char-Lynn, your proven low speed high torque motor supplier, now offers the Char-Lynn 2000 Series motor with our proven Eaton

More information

FUNDAMENTAL TECHNICAL HYDRAULIC CLAMPING INFORMATION

FUNDAMENTAL TECHNICAL HYDRAULIC CLAMPING INFORMATION FUNDAMENTAL TECHNICAL HYDRAULIC CLAMPING INFORMATION This is an uncontrolled document provided for informative purposes only. Product information contained herein is subject to change without notification

More information

Disc Valve Hydraulic Motors 4000 Compact Series

Disc Valve Hydraulic Motors 4000 Compact Series Disc Valve Hydraulic Motors 10.2014 inspired hydraulics. Änderungen und Druckfehler vorbehalten 10.2014 EN EATON_Motoren english Port B Port A Features Shuttle Valve with Back- Pressure Relief Valve Highlights

More information

POWER CLAMPING. Power Clamping. Air-Powered Hydraulic Pumps

POWER CLAMPING. Power Clamping. Air-Powered Hydraulic Pumps Power Clamping Repair Kits... 213 Rotary Couplers...208 Swing Cylinder Arms... 150 Swing Cylinder Bottom Flange... 149 Swing Cylinder Top Flange... 148 Tubing, Steel... 212 Valves, Air Circuit... 202 203

More information

POWER CLAMPING.

POWER CLAMPING. www.jergensinc.com POWER CLAMPING Air Circuit Controls- 2-Hand No Tie Down....59 Booster Clamping Kit....49 Boosters, High Pressure/Volume....47 Booster Installation Kits....48 Boosters, Pre-Fill....44

More information

Disc Valve Hydraulic Motors 2000 Series

Disc Valve Hydraulic Motors 2000 Series Disc Valve Hydraulic Motors 10.2014 inspired hydraulics. Änderungen und Druckfehler vorbehalten 10.2014 EN EATON_Motoren english Highlights Port A Features Three zone design for longer life and true bi-directionality.

More information

6000 Series Highlights

6000 Series Highlights Highlights Features 9 displacements available Presents a multitude of options that make this motor very smart and flexible to apply Benefits Very tough motor for demanding applications Can be used in a

More information

CRITICAL SUCCESS FACTORS

CRITICAL SUCCESS FACTORS Features Critical Success Factors Position Sensing Swing Clamps New Item: Hydraulic Intensifier 4:1 Power to Hold, Prices in Check 1334 East 6th Avenue Emporia, KS 66801 800-992-0236 www.vektek.com R Made

More information

Disc Valve Hydraulic Motors Series 6000

Disc Valve Hydraulic Motors Series 6000 Disc Valve Hydraulic Motors Series 6000 10.2014 inspired hydraulics. Änderungen und Druckfehler vorbehalten 10.2014 EN EATON_Motoren english Highlights Features 9 displacements available Presents a multitude

More information

Powers TM Controls VP 656 Powermite Three-way Mixing Valves (Flared Type)

Powers TM Controls VP 656 Powermite Three-way Mixing Valves (Flared Type) VP 656-3 Powers TM Controls VP 656 Powermite Three-way Mixing Valves (Flared Type) Description The VP 656 Powermite Three-way Mixing Valves are designed for water mixing applications. The valve body is

More information

10,000 Series. Highlights C-6

10,000 Series. Highlights C-6 Highlights Features higher flows Benefits demanding mobile and industrial applications from Applications Description This is the biggest disc valve motor of our line with up to 45 GPM and 24,000 in-lb

More information

6000 Series. Highlights C-5. Description With torque up to 15,000 in-lb and 40 gpm continuous, this motor is packed with power operates very smoothly.

6000 Series. Highlights C-5. Description With torque up to 15,000 in-lb and 40 gpm continuous, this motor is packed with power operates very smoothly. Highlights Features 9 displacements available Presents a multitude of options that make this motor very smart and flexible to apply Benefits Very tough motor for demanding applications Can be used in a

More information

SELKIRK CORP INSTALLATION INSTRUCTION SUPPLEMENT MODEL G - CHIMNEY LINER

SELKIRK CORP INSTALLATION INSTRUCTION SUPPLEMENT MODEL G - CHIMNEY LINER SELKIRK CORP MODEL G - CHIMNEY LINER These instructions are supplemental to the General Installation Instructions for Selkirk Model G, PS, IPS and ZC Single Wall, Double Wall Air & Fiber Insulated Positive

More information

H Low Torque Impact Wrench

H Low Torque Impact Wrench SERVICE MANUAL H8508-3 Low Torque Impact Wrench Serial Code AKW Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this

More information

MCV106A. Hydraulic Displacment Control-PV DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: March 1991

MCV106A. Hydraulic Displacment Control-PV DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: March 1991 DESCRIPTION MCV106A Hydraulic Displacment Control-PV Issued: March 1991 The MCV106A Hydraulic Displacement Control (HDC) is a costeffective hydraulic pump stroke control which uses mechanical feedback

More information

OPERATION AND PARTS MANUAL

OPERATION AND PARTS MANUAL OPERATION AND PARTS MANUAL MODEL NUMBER : PART NUMBER : Revolution 1999-0500 SERIAL NUMBER : BAYNE MACHINE WORKS, INC. PHONE: 864.288.3877 910 FORK SHOALS ROAD TOLL FREE: 800.535.2671 GREENVILLE SC, 29605

More information

Disc Valve Hydraulic Motors

Disc Valve Hydraulic Motors Disc Valve Hydraulic Motors State of the art motors benefiting from years of experience and inovating constantly to fit your demands. C-i Disc Valve Hydraulic Motors Highlights Product Description In the

More information

OPERATION AND PARTS MANUAL

OPERATION AND PARTS MANUAL OPERATION AND PARTS MANUAL MODEL NUMBER : PART NUMBER : BTL 208-12 1999-0212 SERIAL NUMBER : BAYNE MACHINE WORKS, INC. PHONE: 864.288.3877 910 FORK SHOALS ROAD TOLL FREE: 800.535.2671 GREENVILLE SC, 29605

More information

Tugger T-Bolts Coupling (Extension) Nuts Eye Bolts Metric Coupling (Ext.) Nuts Latch Swing Bolts Heavy Hex Nuts...

Tugger T-Bolts Coupling (Extension) Nuts Eye Bolts Metric Coupling (Ext.) Nuts Latch Swing Bolts Heavy Hex Nuts... INDEX Threaded Rod... 4 T-Slot Nuts... 14 Driver Studs - Stainless Steel... 4 Stainless Steel T-Nuts... 14 Driver Studs... 4-5 Stainless Steel Flange Nuts... 15 Driver Studs Various Thread Lengths... 6

More information

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding PAVC Medium Pressure Super Charged Piston Pumps Variable Displacement

More information

Proportional Directional Control Cartridge Valves: PSV10-34 & PSV12-34

Proportional Directional Control Cartridge Valves: PSV10-34 & PSV12-34 Control Cartridge Valves: PSV10-34 & PSV12-34 SCHEMATIC PRESSURE* FLOW CAVITY COIL Page 2 PSV10-34-02 250 BAR 3600 PSI 22 LPM 6 GPM SDC10-4 M16-26W R16-20W Page 4 PSV12-34-02 260 BAR 3770 PSI 50 LPM 13

More information

VALVE ASSEMBLY. Form No "A" "A" Parts List for: (1/4 N.P.T.F.-REF.) (1/4 N.P.T.F.-REF.)

VALVE ASSEMBLY. Form No A A Parts List for: (1/4 N.P.T.F.-REF.) (1/4 N.P.T.F.-REF.) Parts List for: Form No. 108100 SPX Corporation 5885 11th Street Rockford, IL 61109-3699 USA Internet Address: http://www.powerteam.com Tech. Services: (800) 477-8326 Fax: (800) 765-8326 Order Entry: (800)

More information

Track Drive Circuit - General System. Simplified Travel Circuit Diagrams: Neutral Controls Forward Travel Reverse Travel

Track Drive Circuit - General System. Simplified Travel Circuit Diagrams: Neutral Controls Forward Travel Reverse Travel Section 7.1 Track Drive Circuit - General System Simplified Travel Circuit Diagrams: Neutral Controls... 7.1.2 Forward Travel... 7.1.4 Reverse Travel... 7.1.5 General... 7.1.3 Track Drive Circuit: General...

More information

45x90 Strut for mounting flexibility. Long life ceramic bearing

45x90 Strut for mounting flexibility. Long life ceramic bearing Grippers Extreme Force and Torque The concept was developed for applications that impart high acceleration to heavy objects or require extremely long, precisely positioned jaws. These applications put

More information

Installation of Hydraulic Kit STD Controls w/ standard pump/manifold location

Installation of Hydraulic Kit STD Controls w/ standard pump/manifold location BULLETIN MIO-H29RRG048B00 REV A Installation of Hydraulic Kit STD Controls w/ standard pump/manifold location SAFETY PRECAUTIONS If any installation problems are encountered, please call G&B Specialties

More information

CAUTION. Fuel Injection Pump, In-Line, Spill Port Timing

CAUTION. Fuel Injection Pump, In-Line, Spill Port Timing Page 4 of 22 Rotate the crankshaft counterclockwise, as viewed from the front of the engine, to approximately 40 degrees before TDC. Both the RQV and RQV-K governor require the shutdown lever to be in

More information

Delivering innovation through engineering

Delivering innovation through engineering Delivering innovation through engineering +44 1224 727480 Completions & Work-over Operations Bore Selector gives access to either the main production bore or annulus in a traditional vertical xmas tree,

More information

GM - G XXX-XXX. Direct solenoid and solenoid pilot operated valves. Function Port size Flow [Max] Individual mounting. Series 77

GM - G XXX-XXX. Direct solenoid and solenoid pilot operated valves. Function Port size Flow [Max] Individual mounting. Series 77 Direct solenoid and solenoid pilot operated valves Series 77 Function Flow [Max] Individual mounting 3/2 NC, 2/2 NC 1/8-1/4 1.0 Cv Inline OPERATIONAL BENEFITS 1. The 4-way pilot develops maximum shifting

More information

Larger Diameter Hymax Inches in Diameter. <--Use Arrow Keys to Navigate Slides--> press 'escape' key to exit

Larger Diameter Hymax Inches in Diameter. <--Use Arrow Keys to Navigate Slides--> press 'escape' key to exit Larger Diameter Hymax 14 24 Inches in Diameter press 'escape' key to exit Large Diameter Hymax Wide Range of Fit = Reduced Inventory Less Bolts = Fast Installation

More information

T Series with Parking Brake (185-)

T Series with Parking Brake (185-) T Series with Parking Highlights Description Eaton s latest offering in LSHT motor technology is the new T Series Motor with Parking Brake. T Series Motor with Parking Brake utilizes brake pads that rotate

More information

ENGINEERING DATA. High Torque, Low Speed Motors H, S, 2000, 6000, and 10,000 Series. w w w. F l u i D y n e F P. c o m

ENGINEERING DATA. High Torque, Low Speed Motors H, S, 2000, 6000, and 10,000 Series. w w w. F l u i D y n e F P. c o m ENGINEERING DATA High Torque, Low Speed Motors H, S, 2000, 6000, and 10,000 Series Interchangeable with: Charlynn White Ross Parker Danfoss w w w. INDEX Cross Reference Guide...2 Introduction...3 H-Series...4

More information

Failure to heed to any of the following warnings could result in severe bodily injury and/or equipment damage.

Failure to heed to any of the following warnings could result in severe bodily injury and/or equipment damage. INSTALLATION OF HYDRAULIC KIT Page of Bulletin MIH9RRFR08B (Rev 0) SAFETY PRECAUTIONS If any installation problems are encountered, please call G&B Specialties, Inc. for technical assistance before continuing

More information

OPERATION AND PARTS MANUAL

OPERATION AND PARTS MANUAL OPERATION AND PARTS MANUAL MODEL NUMBER : PART NUMBER : DTL 1116 1900-0098 SERIAL NUMBER : BAYNE MACHINE WORKS, INC. PHONE: 864.288.3877 910 FORK SHOALS ROAD TOLL FREE: 800.535.2671 GREENVILLE SC, 29605

More information

A comprehensive range of pneumatic actuators, providing compact, reliable and economical powered operation for all types of quarter-turn valves.

A comprehensive range of pneumatic actuators, providing compact, reliable and economical powered operation for all types of quarter-turn valves. A comprehensive range of pneumatic actuators, providing compact, reliable and economical powered operation for all types of quarter-turn valves. Features Mounting to valve either directly or via bracket,

More information

> clamping force up to kn. > operating pressure up to 500 bar. > piston with internal thread. > for push- and pull operation

> clamping force up to kn. > operating pressure up to 500 bar. > piston with internal thread. > for push- and pull operation Block CYLINDERS for VARIOUS DESIGN APPLICATIONS > clamping force up to 155.5 kn > operating pressure up to 500 bar > piston with internal thread > for push- and pull operation > with longitudinal and cross

More information

OPERATION AND PARTS MANUAL

OPERATION AND PARTS MANUAL OPERATION AND PARTS MANUAL MODEL NUMBER : PART NUMBER : BTL 1114 SO CURBSIDE CARRY CAN 1910-0001 SERIAL NUMBER : BAYNE MACHINE WORKS, INC. PHONE: 864.288.3877 910 FORK SHOALS ROAD TOLL FREE: 800.535.2671

More information

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Pilot Operated Pressure Relief Valve Series R5V (Denison) Characteristics Pilot operated pressure relief valves series R5V have a similar design to the subplate mounted R4V series. The SAE flanges allow to mount the valves directly on the outlet flanges of pumps

More information

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Char-Lynn Disc Valve Hydraulic Motors. h y d r a u l i c s

Solutions. ydraulics. We Manufacture. H y d r a u l i c s. Char-Lynn Disc Valve Hydraulic Motors. h y d r a u l i c s H y d r a u l i c s ydraulics Char-Lynn Disc Valve Hydraulic Motors h y d r a u l i c s 4000 Compact Series Standard, Wheel, and Bearingless Hydraulic Motors We Manufacture 11-01-113 EN-0400 Solutions

More information

LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS

LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS Fluid Power Specialist Since 1948 LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS Copyright 2019, Almo Manifold & Tool Co. All rights reserved. All attempts have been made to make the information in

More information

767 Hydraulic Hand Pump

767 Hydraulic Hand Pump INSTRUCTION MANUAL 767 Hydraulic Hand Pump Serial Code ABM Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this product

More information

Pressure Sensor No Series

Pressure Sensor No Series Sales Manual Section 335 PRODUCT SPECIFICATION 84372 SERIES Pressure Sensor No. 84372-Series GENERAL DESCRIPTION The patented* No. 84372-Series Pressure Sensor contains a weatherproof, snap-acting valve

More information

Operation and Maintenance Manual Model.75,, 3, 5, 8, 0, 0, 5, 35, 50 http://www.torsionx.com Use the MaxDrv Series Square Drive Torque Wrench Model.75,, 3, 5, 8, 0, 0, 5, 35, 50 to install and remove threaded

More information

whitedriveproducts SERIES Hydraulic Motor LIGHT DUTY

whitedriveproducts SERIES Hydraulic Motor LIGHT DUTY whitedriveproducts SERIES 145-146 - LIGHT DUTY Hydraulic Motor www.cenhyd.com 1(800)264-9571 WD WD (All Series) whitedriveproducts overview The WD motor series is an economical solution for light duty

More information

HTR TIE-ROD CYLINDERS H I K M N TUBE OD

HTR TIE-ROD CYLINDERS H I K M N TUBE OD 1 Brand Cylinders LINE THE HTR Pressure Ratings: 2" - 4" Bore = 2500 PSI, 5" Bore = 2000 PSI BORE (INCH) B C D E F G = J 2.0 1.015 2.125 1.625 1.000 1.000 1.142 2.5 1.015 2.125 1.625 1.000 1.000 1.142

More information

Form No , 9 5, 6. Parts List for: X1A1 AIR DRIVEN WITH REMOTE CONTROL HYDRAULIC PUMP. Max. Capacity: 10,000 PSI

Form No , 9 5, 6. Parts List for: X1A1 AIR DRIVEN WITH REMOTE CONTROL HYDRAULIC PUMP. Max. Capacity: 10,000 PSI Form No. 101249 Parts List for: X1A1 AIR DRIVEN WITH REMOTE CONTROL HYDRAULIC PUMP Max. Capacity: 10,000 PSI Air Motor Assembly See sheet 3 of 6 13 12 1 11 10 8, 9 Basic Pump Assembly See sheet 4 of 6

More information

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body VF 599-1 Description Features Application The Flowrite VF 599 series two-way valves are designed to work with either a pneumatic

More information

Failure to heed to any of the following warnings could result in severe bodily injury and/or equipment damage.

Failure to heed to any of the following warnings could result in severe bodily injury and/or equipment damage. INSTALLATION OF HYDRAULIC KIT Page of Bulletin MIH9RRGX080 (Rev 0) SAFETY PRECAUTIONS If any installation problems are encountered, please call G&B Specialties, Inc. for technical assistance before continuing

More information

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s

Solutions. We Manufacture. H y d r a u l i c s. Eaton Medium Duty Piston Pump. h y d r a u l i c s H y d r a u l i c s ydraulics Eaton Medium Duty Piston Pump h y d r a u l i c s Model 70122, 70422, 70423, and 70523 or -Flow Compensated Piston Pumps We Manufacture April 1997 Solutions S o l u t i o

More information

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body VF 599-1 VF114R1 VF115R1 Description Features Application The Flowrite VF 599 series two-way valves are designed to work with either

More information

Bulleti n BF Kinney Water-Cooled Burner Valve* for Blast Furnace Stoves. Fast, Safe Stove Changing from Gas to Blast.

Bulleti n BF Kinney Water-Cooled Burner Valve* for Blast Furnace Stoves. Fast, Safe Stove Changing from Gas to Blast. Bulleti n BF 113.2 n Kinney Water-Cooled Burner Valve* for Blast Furnace Stoves o Fast Safe Stove Changing from Gas to Blast J - Patented 2! J...-' Stove changing from "gas" to "blast" is now fast and

More information

LS100L Battery-powered Punch Driver

LS100L Battery-powered Punch Driver OPERATION MANUAL Serial Number GATOR LS100L Battery-powered Driver Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this

More information

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body

Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body Flowrite VF 599 Series Two-Way Valves 2-1/2 to 6-inch Flanged Iron Body VF 599-1 Description Features Application The Flowrite VF 599 series two-way valves are designed to work with either a pneumatic

More information

Series PAVC Variable Volume, Piston Pumps

Series PAVC Variable Volume, Piston Pumps Series PVC Variable Volume, Piston Pumps Catalog 26-11-1/US 95 Introduction Series PVC Quick Reference Data Chart Pump Model Displacement CM 3 /REV (IN 3 /REV) Pump Delivery *pprox. Noise Levels db() Input

More information

Work supports - Collet-Lok design

Work supports - Collet-Lok design ork supports - ollet-ok design Shown: PS-1, PTS-1 Hydraulically locked, mechanically maintained work support ollet-ok products ollet-ok design allows the work support to maintain support position after

More information

03/2017 SRA SELF-ADJUSTING SWING CLAMP CYLINDERS

03/2017 SRA SELF-ADJUSTING SWING CLAMP CYLINDERS SRA SELF-ADJUSTING SWING CLAMP CYLINDERS SRA SELF-ADJUSTING SWING CLAMP CYLINDERS PATENT-REGISTERED SRA CYLINDERS Double-acting swing clamp cylinders with integrated work support of the SRA series have

More information

Installation, Operation, and Maintenance Manual for the Spears NM Series RACK AND PINION PNEUMATIC ACTUATORS

Installation, Operation, and Maintenance Manual for the Spears NM Series RACK AND PINION PNEUMATIC ACTUATORS Installation, Operation, and Maintenance Manual for the Spears NM Series RACK AND PINION PNEUMATIC ACTUATORS TABLE OF CONTENTS I. Introduction... 04 A. Storage... Pg.04 II. Identification... 05 A. General

More information

Installation, Operation, and Maintenance Manual for Milwaukee Valve

Installation, Operation, and Maintenance Manual for Milwaukee Valve Installation, Operation, and Maintenance Manual for Milwaukee Valve RACK AND PINION PNEUMATIC ACTUATORS TABLE OF CONTENTS I. Introduction... 04 A. Storage... Pg.04 II. Identification... 05 A. General Identification...

More information

LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS

LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS Fluid Power Specialist Since 1948 LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS Copyright 2018, Almo Manifold & Tool Co. All rights reserved. All attempts have been made to make the information in

More information

Form No Parts List for: RWP55 RWP55-4 MODEL C HYDRAULIC PUMP AIR DRIVEN WITH REMOTE CONTROL GENERAL ASS'Y SIDE VIEW SECTION A-A

Form No Parts List for: RWP55 RWP55-4 MODEL C HYDRAULIC PUMP AIR DRIVEN WITH REMOTE CONTROL GENERAL ASS'Y SIDE VIEW SECTION A-A Parts List for: Form No. 000339 RWP55 RWP55-4 MODEL C HYDRAULIC PUMP AIR DRIVEN WITH REMOTE CONTROL GENERAL ASS'Y SIDE VIEW 3 9, 0 4 5 6 6 5 4, 3 9,0 SPX Hydraulic Technologies, Rockford, IL 609 USA powerteam.com

More information

PRESSURE CONTROLS TECNORD

PRESSURE CONTROLS TECNORD Pressure Reducing / Relieving Valves GPM PSI LPM BAR MODEL PAGE 1 4 38 276 DF-PRP 174 2 3 76 27 SK-PRP 176 1 4 38 276 DF-PWP 178 Typical Schematic Typical application for the PRP and PWP is multi-system

More information

APECS 0225 Linear Actuators

APECS 0225 Linear Actuators Product Specification 36581 APECS 0225 Linear Actuators APPLICATIONS APECS 0225 linear actuators provide proportional fuel control for construction, industrial, and agricultural equipment. Speed governing

More information

SF-120, SF-170, SF-250, SF-400 Bearing Mounted, Flange Mounted, SFC-120, SFC-170, SFC-250, SFC-400 Bearing Mounted, Flange Mounted

SF-120, SF-170, SF-250, SF-400 Bearing Mounted, Flange Mounted, SFC-120, SFC-170, SFC-250, SFC-400 Bearing Mounted, Flange Mounted SF-120, SF-170, SF-250, SF-400 Bearing Mounted, Flange Mounted, SFC-120, SFC-170, SFC-250, SFC-400 Bearing Mounted, Flange Mounted P-0200-WE 819-0481 Installation Instructions An Altra Industrial Motion

More information

Section 6.1. Implement Circuit - General System. General: Implement Control Valve: Implement Circuit

Section 6.1. Implement Circuit - General System. General: Implement Control Valve: Implement Circuit Section 6.1 Implement Circuit - General System General: Implement Circuit... 6.1.3 Implement Pump Breakdown... 6.1.4 Operational Description: General... 6.1.5 Compensator Control... 6.1.6 Standby Condition...

More information

Section 7.1. Wheel Drive Circuit - General System

Section 7.1. Wheel Drive Circuit - General System Section 7.1 Wheel Drive Circuit - General System Simplified Travel Circuit Diagrams: Neutral Controls... 7.1.2 Forward Travel... 7.1.4 Reverse Travel... 7.1.5 General... 7.1.3 Wheel Drive Circuit: General...

More information

18. KSP 18. KSP 18.1 1200016 1200016 18.2 18.3 1200016 1200016 18.4 18.5 1200016 1200016 18.6 18.7 1200016 1200016 18.8 18.9 1200016 DARLEY BASIC ASSEMBLING TECHNIQUES Work with clean tools in clean surroundings

More information

WHITE MOTORS. Features. Max Torque lb-in (Nm) Cont. Inter. *Stall

WHITE MOTORS. Features. Max Torque lb-in (Nm) Cont. Inter. *Stall Due to its case drain design, the Series motor is an excellent medium size motor for applications with high duty cycles or frequent direction reversals. The case drain design produces a number of benefits

More information

SERVICE LETTER PIPER AIRCRAFT CORPORATION, LOCK HAVEN, PA., U. S. A. Service Letter No. 315 February 4, TO: All Distributors, Dealers and Owners

SERVICE LETTER PIPER AIRCRAFT CORPORATION, LOCK HAVEN, PA., U. S. A. Service Letter No. 315 February 4, TO: All Distributors, Dealers and Owners SERVICE LETTER Service Letter No. 315 February 4, 1959 TO: All Distributors, Dealers and Owners SUBJECT: PA-24 Comanche Landing Gear Transmission Assembly We have been receiving warranty claims for the

More information

Instruction Sheet. Booster and Wand PRODUCTION AUTOMATION IMPORTANT RECEIVING INSTRUCTIONS CONTENTS

Instruction Sheet. Booster and Wand PRODUCTION AUTOMATION IMPORTANT RECEIVING INSTRUCTIONS CONTENTS PRODUCTION AUTOMATION L1840 Rev. O 05/94 IMPORTANT RECEIVING INSTRUCTIONS Instruction Sheet Booster and Wand Visually inspect all components for shipping damage. If any shipping damage is found, notify

More information

Pneumatic Actuator Durastroke Series 2000 Installation & Maintenance Instructions

Pneumatic Actuator Durastroke Series 2000 Installation & Maintenance Instructions Pneumatic Actuator Durastroke Series 2000 Installation & Maintenance Instructions INSTALLATION Installation of Airtech Products Durastroke pneumatic actuator is a simple three-step process; Mounting of

More information

RUBBER SLEEVE KNIFE GATE VALVE

RUBBER SLEEVE KNIFE GATE VALVE RUBBER SLEEVE KNIFE GATE VALVE The model knife gate is a bi-directional wafer valve equipped with two metallic coved rubber sleeves designed for use in the handling of abrasive slurries, mainly in industries

More information

INSTALLATION MANUAL - v4

INSTALLATION MANUAL - v4 I-LOCKTM COUPLER INSTALLATION MANUAL - v4 SPECIAL NOTE Your new Wedgelock Coupler fitted with the I-LOCK TM Safety Device requires the installation of a third hydraulic line - please follow the instructions

More information

HexPro Series Low Profile Wrenches

HexPro Series Low Profile Wrenches HexPro Series Low Profile Wrenches Operation and Maintenance Manual Model 2HP 4HP 8HP 14HP 30HP www.torquetoolsinc.com Use the HEXPRO Series Low Profile Wrenches Model 2HP 4HP 8HP 14HP 30HP to install

More information

Features and Benefits

Features and Benefits ...........................................................3-14 Features and Benefits..............................................................................3 How To Order....................................................................................4

More information

CDM CREEPDRIVE MOTOR

CDM CREEPDRIVE MOTOR CDM 222-050 CREEPDRIVE MOTOR T E C H N I C A L C A T A L O G FOREWORD Product description The vehicle equipped with CDM 222-050 motor features two independent transmission types : hydrostatic and, mechanical.

More information

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve: Section 6.1 Implement Circuit - General System General: TF Configuration... 6.1.3 TB Configurations... 6.1.5 Implement Pump Breakdown... 6.1.6 Operational Description: General... 6.1.7 Compensator Control...

More information

VB-8000 Series VB-9313 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents. Valve and Actuator Selection Procedure

VB-8000 Series VB-9313 Series. Selection Guide. Applications. Applicable Literature. Selection Guide Contents. Valve and Actuator Selection Procedure Selection Guide VB-8000 Series VB-9313 Series Schneider ElectricVB-8000 Series and VB-9000 Series 2-1/2 to 6 Globe Valves with Schneider Electric NSR Forta M800A and M1500A Actuators Applications Schneider

More information

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P P200-3100 SERIES PUMPS 18mm Versions Nickle-Aluminum Bronze Models: P217-3100, P218-3100, P219-3100, P220-3100, P221-3100, P227-3100, P230-3100 Triplex Ceramic Plunger Pump Operating Instructions/ Repair

More information

1998 Saab 900 SE ENGINES Saab 2.0L & 2.3L 4-Cylinder

1998 Saab 900 SE ENGINES Saab 2.0L & 2.3L 4-Cylinder Removal & Installation See VALVE SPRINGS under CYLINDER HEAD under OVERHAUL. CAMSHAFT Removal 1. Rotate crankshaft until "0" mark on flywheel aligns with timing mark on flywheel cover. Remove inspection

More information

Operation and Maintenance Instructions for Bettis GVO-C Series GVO-CLP-SR Pneumatic Actuators

Operation and Maintenance Instructions for Bettis GVO-C Series GVO-CLP-SR Pneumatic Actuators Part Number: GVO-CLP-SR.IOM.1003, Rev. 0 Release: March 2016 Operation and Maintenance Instructions for Bettis GVO-C Series GVO-CLP-SR Pneumatic Actuators Part Number: GVO-CLP-SR.IOM.1003, Rev. 0 Table

More information

Frame and Running Gear Data: CVIP. A. Performance Characteristics 4C-VIP 5C-VIP 6C-VIP. Stroke (in.) Rod Diameter (in.)

Frame and Running Gear Data: CVIP. A. Performance Characteristics 4C-VIP 5C-VIP 6C-VIP. Stroke (in.) Rod Diameter (in.) Frame and Running Gear Data: CVIP I. STANDARD FRAME AND RUNNING GEAR ASSEMBLIES A. Performance Characteristics 4C-VIP 5C-VIP 6C-VIP 1.0 General Stroke (in.) 4.0 5.0 6.0 Rod Diameter (in.) 2.0 2.0 2.0 Maximum

More information