INSTRUCTION MANUAL DIGITRAC % 2 DIGITAL TENSION READOUT AND CONTROL

Size: px
Start display at page:

Download "INSTRUCTION MANUAL DIGITRAC % 2 DIGITAL TENSION READOUT AND CONTROL"

Transcription

1 Magnetic Power Systems, Inc Manufacturers Drive. Fenton, MO Tel: Fax: INSTRUCTION MANUAL DIGITRAC % 2 DIGITAL TENSION READOUT AND CONTROL TABLE OF CONTENTS Section Title Page Figure Title Page 1 Introduction... 2 Specifications Installation Wiring Isolated Inputs Electrical Connections System Types Setup and Calibration PA-2 Installation PA-2/PA-90 Installation Wiring Diagrams Optional Features Outline Dimensions Trouble Shooting Screen Flow Chart Reset Procedures All of the information herein is the exclusive proprietary property of Magnetic Power Systems, Inc., and is disclosed with the understanding that it will be retained in confidence and will neither be duplicated nor copied in whole or in part nor be used for any purpose other than for which disclosed. Copyright 2002, all rights reserved. 850A /02 Rev. D

2 1. INTRODUCTION The MAGPOWR % Model DIGITRAC % 2 is a microprocessor based control, designed for precise closed loop tension control of a moving web. All data entry and calibration is done through the touch pad keyboard. The DIGITRAC 2 is capable of controlling web tension in unwind, rewind, or point-to-point applications. Throughout this manual, bold words or symbols represent keystrokes. 2. INSTALLATION INSTALLATION The DIGITRAC 2, Model D2E and its variants are intended for mounting on any flat vertical surface capable of supporting it. See Figure 4 for dimensions. The D2E meets the environmental and mechanical requirements of EN50178 with the exception that the degree of protection provided by the D2E enclosure is IP65 which is more stringent than the standard. If the IP65 rating is required in the final installation, sealing type cable grips should be used for cable entry. Four mounting holes are provided for attachment of the D2E to the mounting surface. The means of attachment should comply with the essential requirements of the appropriate standard(s) and is the responsibility of the installer. The DIGITRAC 2, Model D2 and its variants are intended for installation through a DIN panel opening. The panel itself should exhibit sufficient strength to support the weight of the D2 as well as insure the integrity of the environmental seal. The D2 maintains a degree of protection of IP65 over its front panel. It also meets the environmental and mechanical requirements of EN The D2 mounting clips found on both sides of the enclosure behind the front panel will accommodate panel thickness of 0.06 inches (1.5mm) to 0.5 inches (12mm). Wiring to and from the enclosure must be done with double or reinforced insulation or protective screening which provides protective separation. All wiring outside either of the DIGITRAC 2 enclosures should comply with the essential requirements of the appropriate standard(s) and is the responsibility of the installer. If using a magnetic particle clutch or brake, see Section 5 to install the Model PA-2 or PA-90 Power Amplifier. WARNING: DISCONNECT MAINS BEFORE OPENING ENCLOSURE MAINTENANCE The only maintenance that may be required on DIGITRAC 2 is fuse replacement. Replacement of any fuse requires opening the enclosure, which circumvents the enclosure IP rating. To replace a fuse: On Model D2 and its variants: On Model D2E and its variants: 1. Disconnect the supply mains. 1. Disconnect the supply mains. 2. Remove the two screws on the rear of the D2 2. Open the door of the D2E by loosening the which retain the top cover. two retaining screws. 3. Remove the top cover. 3. Remove the PA-2 or PA-90 power amplifier 4. Remove the PA-2 or PA-90 power amplifier if present. if present 4. Remove and replace the blown fuse. 5. Remove and replace the blown fuse. 5. Re-install the PA-2 or PA Re-install the PA-2 or PA-90 and the top cover. 6. Close the door and re-tighten the retaining screws. 7. Reconnect supply mains. 7. Reconnect supply mains. 2

3 3. ELECTRICAL CONNECTIONS Figure 3 shows the connections that are required for the basic DIGITRAC 2 system. They are: 115 or 230 vac power One or two MAGPOWR tension sensors RUN/STOP using the DIGITRAC 2 internal logic supply OUTPUT to clutch, brake, motor controller, etc Power Amplifier input (if used) 115 vac for 90 vdc clutch or brake, or 24 vdc for a 24 vdc clutch or brake. See Section 6 for other options and connections. Route AC power away from sensor and control wiring. MAGPOWR sensor cables are color coded on the nameplate. Run all wiring in shielded cable. Connect shields to the enclosure using the standoffs provided. Maximum shield length and maximum length of wires outside of the shield is 3 inches (75 mm). 4. SETUP AND CALIBRATION Apply power. Screen contrast can be adjusted using SHIFT,B and or. SETUP # STATUS A = AUTOMATIC S = STOPPING H = HOLD M = MANUAL E = E-STOP OFF ANALOG BAR GRAPH OF TENSION DIGITAL READOUT OF TENSION USE CONFIGURE TO SELECT UNITS & LANGUAGE The home screen (above) always appears at power up. HOME also returns you to this screen. Keyboard Layout and Programming See Cover for keypad layout. CLEAR clears numeric inputs and other keystrokes. SHIFT selects the shifted (white) functions NEXT and PRIOR change to next or prior screens. or change the value of the parameter displayed on the screen. See Figure 6 for a complete programming flow chart. 3

4 4.1 System Set up Basic calibration cannot be performed if E-STOP is open, or if RUN/STOP is in run mode. A complete flow chart is shown in Figure 6. To begin basic calibration, do the following: Press SHIFT, Press PROGram, Use or to select )PROGRAM: CALIBRATE(, Press NEXT to select )CALIBRATE BASIC(, Press NEXT to display )SELECT SYSTEM(. Use or to select desired system type. See Figure 1 for a description of system types. If using a regenerative drive, see Section 6.9 to determine system type. Then continue through the flow chart at right entering the desired data in each screen. 4.2 Tension Sensor Calibration NOTE: Continuing beyond this point will erase any previous sensor calibration in this setup. Sensor calibration will require loading the sensor roll with a known force. The known force will be applied using a weight and a temporary web as shown below. The temporary web should be threaded as the web would normally be threaded in the machine to ensure the same wrap angles. In wide web applications, the known force should be applied near the center of the sensing roll using a narrow web such as a rope. Follow the steps at the right to calibrate the tension sensors. 4

5 4.3 Dynamic Tuning Use NEXT or PRIOR to enter the DESIRED TENSION screen and enter the desired value. Follow the flow chart, Figure 6, to enter CALIBRATE DYNAMICS. When asked to OPTIMIZE in any of the following steps do the following: 1. Press and hold until the tension becomes unstable. 2. Press and hold until the tension is again stable. System stability can be observed on the bar graph. Run the machine at a moderate speed, with the control in AUTOMATIC mode and perform dynamic calibration using the above procedure in the indicated sequence. STABility is normally optimized at full roll. COMPensation is normally optimized at core. If the tension becomes unstable at some other roll diameter see )Tension Oscillates( in Troubleshooting, Section INSTALLATION OF MODEL PA-90 or PA-2 Power Amplifier (if used) 5.1 PA-90 Install the PA-90 before applying power to the control Remove the D2 cover, or open the D2E door. Set JP6 on the D2 p.c. board to 0-10V and voltage. Set JP1 on the power amplifier for the desired output current range. On Model D2, unplug TB6 and remove the knockout from the rear of the enclosure. Mount Power Amplifier per Figure 2 using the standoffs provided with the PA-90. Resecure cover or door. When using the PA-90, the DIGITRAC 2 s 0 to 10 vdc control output is still active but no longer isolated, and is referenced to the AC line. 5.2 PA-2 Install the PA-2 before applying power to the control. Remove the D2 cover, or open the D2E door. Set JP6 on the main PCB to )0-10V( and )VOLTAGE(. Set JP1 and JP2 on the power amplifier per Figure 2 for the desired output voltage and current range. On model D2 unplug TB7 and remove the knock-out from the rear of the enclosure. Mount Power Amplifier per Figure 2 using the standoffs provided with the PA-2. When using the PA-2, the DIGITRAC 2 s 0 to 10 vdc control output is still active but no longer isolated, and is referenced to the AC line. 5

6 6. OPTIONAL CONNECTIONS, FUNCTIONS AND OTHER TECHNICAL INFORMATION HARDWARE TABLE OF CONTENTS ALTERNATE TENSION INPUTS DIAMETER INPUT WEB SPEED INPUT RUN/STOP E-STOP REMOTE TENSION ON/OFF ISOLATED LOGIC INPUTS (RUN/STOP, ETC.) SELECTING OUTPUT VOLTAGE/CURRENT vdc SUPPLY PROGRAM OPTIONS OPERATOR SCREENS UNITS OF MEASURE LANGUAGE MANUAL MODE TAPER TENSION INERTIA COMPENSATION HOLD LEVEL CONTROL OPTIMIZE METHOD SETUPS AND COPY SETUPS SECURITY ITEM NUMBERS AND SCREEN DESCRIPTIONS ALTERNATE TENSION INPUTS 100 mv/v TENSION SENSORS On the main PCB cut jumpers JP11 and JP12. Connect wires to TB2 and TB3 as shown using shielded wiring. Only one full bridge can be used. 10 vdc TENSION SIGNAL On main PCB cut jumpers JP10, JP11, JP12 and JP13. Connect signal between terminals TB2.1(+) and TB2.2(-) using shielded wiring. TB2.2(-) should also be connected to TB3.1 (GND). 6.2 DIAMETER INPUT The DIGITRAC 2 uses the diameter of the roll on unwinds and rewinds for inertia compensated stopping and on rewinds for providing taper tension. When no diameter input is provided the DIGITRAC 2 estimates diameter. Using a diameter input gives more accurate results. Select the DIAMETER INPUT TYPE under PROGRAM-CONFIGURE. Connect a diameter sensor between TB3.7(+) and TB3.6(-) using shielded wiring. VOLTAGE (0 to 10 vdc) Voltage must be proportional to diameter (i.e. the output at core cannot be 0 vdc). Select )VOLTAGE( on JP15 on the main PCB. 6

7 PULSE (0 to 5 vdc, 0 to10,000 pps) Diameter is calculated by dividing web speed by this signal, which is proportional to unwind/rewind RPM. Select )PULSE( on JP15 on main PCB. TB3.5 can be used to supply 5vdc to the pulse generator. See current limitation in Paragraph 6.9. A web speed signal must be provided if the diameter signal is )PULSE(. 6.3 WEB SPEED INPUT The DIGITRAC 2 needs a web speed input if a PULSE type input is used to calculate diameter of the roll on unwinds and rewinds. Select the SPEED INPUT TYPE under PROGRAM-CONFIGURE. Connect a web speed sensor between TB3.8(+) and TB3.6(-) using shielded wiring. VOLTAGE (0 to 10 vdc) Select )VOLTAGE( ON JP9 on main PCB. PULSE (0 to 5vdc, 0 to 10,000 pps) Select )PULSE( on JP9 on main PCB. TB3.5 can be used to supply 5 vdc to the pulse generator. See current limitation in Paragraph LOGIC INPUTS The logic inputs may be isolated with an external (5 to 24 vdc) power supply to interface with other equipment or for increased noise immunity. Set JP7-8 (OPTO SUPPLY) to EXT (external) for an external isolated 5 to 24 vdc power supply as shown in Figure 5. The current flowing in the logic inputs switches is 2 madc RUN/STOP Connect TB4.4 to TB4.3 to initiate the stopping function. During STOP TIME the DIGITRAC 2 continues to control tension as a closed loop system but INERTIA COMP and STOP MULTIPLIER are also activated. See Section 6.7 to use isolated logic inputs (5 to 24vdc) E-STOP (E-STOP IS AN AUXILIARY FUNCTION NOT INTENDED TO PROVIDE CATEGORY 1 SAFETY PROTECTION) Open the connection between TB4.2 and TB4.1 to initiate E-STOP. On unwinds the output goes full on. On all other systems the output goes to zero. See Section 6.7 to use isolated logic inputs (5 to 24vdc) REMOTE TENSION ON/OFF TENSION OFF sets the output to zero for all types of systems. For Type 2 and 3 systems OUTPUT LEVEL will display 100% since these systems are reverse acting (i.e. tension decreases with increasing output). Either of two optional modes of operation are selected using PROGRAM-CONFIGURE. TOGGLE duplicates TENSION ON/OFF on the keypad. A momentary connection should be made between TB4.5 and TB4.3 will toggle between TENSION ON and OFF. The TENSION ON/OFF key remains functional. LEVEL turns TENSION OFF when TB4.5 is connected to TB4.3. The TENSION ON/OFF key is disabled. See Section 6.7 to use isolated logic inputs (5 to 24vdc). 6.5 ISOLATED LOGIC INPUTS If it is desired to isolate the logic inputs on TB4 to interface with other equipment or for increased noise immunity, an external power supply can be used as shown in Figure 15. On the main PCB set JP8-7 (OPTO SUPPLY) to EXT (external). 7

8 6.6 SELECTING OUTPUT VOLTAGE/CURRENT The output voltage/current at TB5.1(+) and TB5.2(-) is set by positioning jumpers on JP6 as shown below. JP6 must be set for 0 to 10 vdc when the PA-2 or PA-90 Power Amplifier is used. The 10 vdc to +10 vdc output is normally used with regenerative drives in torque mode. If the drive is wired so that +10vdc creates torque in the first quadrant, use SYSTEM TYPE 2 or 4. Otherwise use SYSTEM TYPE 1 or 3. In either case tension can now increase or decrease from T1 to T2. See Figure 1. If the PA-2 or PA-90 Power Amplifier is used, select current and voltage per Figure vdc SUPPLY (TB3.5(+) to TB3.6(-)) Total current capacity is 150 madc. Subtract sensor current of: 30 madc per MAGPOWR sensor 45 madc per 120 ohm sensor connected per Section OPERATOR SCREENS The operator screens are those normally used during machine operation and are accessed using NEXT ITEM or PRIOR ITEM from the HOME screen. These are the only screens affected by the language selected per Section 6.10 and the only screens which are accessible when security is set per Section The operator screens are )TENSION(, )DESIRED TENSION(, )MANUAL LEVEL(, )OUTPUT LEVEL(, )TAPER PERCENT( (if TAPER TENSION is selected), and )WEB SPOOL WIDTH( (if INERTIA COMPENSATION is selected). 6.9 UNITS OF MEASURE PROGRAM-CONFIGURE can be used to select units of measure from: 6.10 LANGUAGE ENGLISH (lb, in) METRIC (kg, mm) METRIC (n, mm) PROGRAM-CONFIGURE can be used to select different languages. The selected language is used for the operator screens which are )TENSION(, )DESIRED TENSION(, )MANUAL LEVEL(, )OUTPUT LEVEL(, )TAPER PERCENT( and )WEB SPOOL WIDTH(. The available languages are: ENGLISH (factory default) FRANCAIS DEUTSCH ESPANOL ITALIANO 8

9 6.11 MANUAL MODE Switch to MANUAL mode at any time using SHIFT,. The output is now fixed at the level set in the MANUAL LEVEL screen. Switch back to AUTOMATIC mode using SHIFT, 6.12 TAPER TENSION Taper tension is used on rewinds to make better rolls by reducing full roll tension compared to core tension. Use PROGRAM-CONFIGURE to select TAPER TENSION. Input the CORE DIAMETER and FULL ROLL DIAMETER. TAPER PERCENT can now be entered on an operator screen. Percent taper is defined as the percent decrease in tension from core to full roll. If a diameter input is not used the DIGITRAC 2 estimates diameter. More accurate results are obtained if a diameter input is provided. See Section 6.2. Either way, diameter must be calibrated using PROGRAM- CALIBRATE-DIAMETER. When calibrating diameter, set TAPER PERCENT to INERTIA COMPENSATION Extra torque is often needed to help stop large unwind rolls. STOP MULTIPLIER is available to increase the output as a multiple of the present running torque. If better stopping results are required, they can be attained by selecting INERTIA COMP using PROGRAM-CONFIGURE. The DIGITRAC 2 asks for information needed to calculate the inertia of the unwind roll. The DIGITRAC 2 needs this information to calculate the inertia and required stopping torque as the roll diameter changes. If a diameter input is not used, the DIGITRAC 2 estimates diameter. More accurate results are obtained if a diameter input is provided. See Section 6.2. Either way, diameter must be calibrated using PROGRAM- CALIBRATE-DIAMETER. You must select INERTIA COMP before calibrating diameter. Diameter must be calibrated while the machine is running, so required stopping torque can be calculated. The DIGITRAC 2 must also know roll width to calculate roll inertia. A new screen now appears in the operator loop to input this information when INERTIA COMP is selected HOLD LEVEL CONTROL During normal automatic operation the output changes to correct for changes in DESIRED TENSION, roll diameter, etc. During the STOP TIME the DIGITRAC 2 is still in automatic mode, but the output is momentarily changed by STOP MULTIPLIER or INERTIA COMP to help stop the unwind roll. At the end of STOP TIME the DIGITRAC 2 switches to HOLD mode. In HOLD mode the output is fixed at the HOLD LEVEL. PROGRAM- CONFIGURE can be used to set HOLD LEVEL CHANGES WITH TENSION and / or HOLD LEVEL CHANGES WITH DIAMETER OPTIMIZE METHOD You should normally select PI (Proportional-Integral) for tension control applications. OPTIMIZE changes P and I to give optimum response. For special applications PID (Proportional-Integral-Derivative) can be selected using PROGRAM-CONFIGURE. 9

10 6.16 SETUPS AND COPY SETUPS There are six independent setups. Each contains its own complete set of parameters. Switch between setups only while stopped using SHIFT, 1, etc. Each setup can be calibrated individually as described in Section 4, or the sensor calibration and parameters in any one setup can be copied to any other setup. Complete setups can be copied using PROGRAM-COPY SETUPS. COPY SETUPS always copies from a selected setup to the present setup. You can also copy the factory DEFAULTS to the present setup PROGRAM-SECURITY PROGRAM-SECURITY can be used to prevent changes to all the programming parameters. When secured, only values in the operator screens can be changed ITEM NUMBERS AND SCREEN DESCRIPTIONS The numbers following each screen parameter can be used to change the value using SHIFT, ITEM. OPERATOR SCREENS TENSION DESIRED TENSION (18) CORE TENSION (18) MANUAL LEVEL (48) OUTPUT LEVEL TAPER PERCENT (20) WEB SPOOL WIDTH (10) Displays current measured tension, setup number and operating mode. The tension set point for AUTOMATIC mode and STOPPING mode. (Does not appear when taper tension is used). This is the DESIRED TENSION at CORE DIAMETER when taper tension is used. The output set point percent when in MANUAL mode. Current output as a percent of maximum. Appears only when taper tension is used. The core tension is reduced by this percentage as the rewind roll increases to FULL ROLL DIAMETER. Appears only when inertia comp is used. Enter the width of the present web to enable calculation of roll inertia. PROGRAM-PARAMETER SCREENS BAR GRAPH TIME (29) DERIVATIVE TIME (34) ERROR LIMIT (19) HOLD LEVEL (26) INTEGRATOR TIME (32) NUMERIC DISPLAY TIME (28) OUTPUT LIMIT (21) Update time for the tension / output bar graph. Default is.050 sec. Part of PID control. Gives an output adjustment proportional to the rate of change of tension error. Error is the difference between the desired tension and the measured tension. This value limits the percent of error that is acted upon. The output will stay at this percent level while in HOLD mode. This time adjusts the response to errors. Larger values slow down the response to rapidly changing error. Update time for the tension / output digital readout. The output will not go above this percent of maximum.

11 PROPORTIONAL GAIN (33) START TIME (22) STOP MULTIPLIER (24) STOP TIME (23) Generates an output adjustment proportional to the error. Provides a soft-start when starting with a slack web. The output is limited to the HOLD LEVEL at start, but the limit level is increased with time. This is the time taken to increase the limit to full output. A longer start time will provide a softer start. Upon receipt of a stop signal, the output is increased by this multiplier (1 creates no increase). Since the output is proportional to roll diameter, this is a simple adjustment for roll inertia. This is the time that DIGITRAC 2 stays in STOPPING (automatic) mode after the stop signal is received. At the end of this time the control goes to HOLD mode. Stop time should be slightly longer than actual machine stopping time. PROGRAM-CONFIGURE SCREENS DIAMETER INPUT TYPE (11) IS INERTIA COMP USED IS TAPER TENSION USED HOLD LEVEL CHANGES WITH DIAMETER HOLD LEVEL CHANGES WITH TENSION OUTPUT RANGE OPTIMIZE METHOD (44) SELECT LANGUAGE SELECT UNITS (42) SPEED INPUT TYPE (47) TENSION ON/OFF NONE, VOLTAGE, or PULSE. YES, NO YES, NO YES, NO YES, NO Normal, -10 vdc to +10 vdc PI or PID. ENGLISH, FRANCAIS, DEUTSCH, ESPANOL, or ITALIANO (lb, in), (kgm, mm), (n, mm) NONE, VOLTAGE, or PULSE. TOGGLE, LEVEL. The following appear only if taper tension is used: CORE DIAMETER (14) FULL ROLL DIA. (12) CORE TENSION is commanded at this diameter. At this diameter the tension will be reduced by the taper percent. 11

12 The following appear only if inertia comp is used: DIAMETER AT THIS WEIGHT ROLL WEIGHT RUNNING VELOCITY TIME TO ZERO SPEED WIDTH AT THIS WEIGHT The roll diameter at the entered weight. Diameter must be calibrated while the web is running. It is not necessary to calibrate at the maximum velocity. The roll weight at any diameter in lbs or kgm. The maximum running web velocity. Typical velocity can be used. The time it takes the machine to stop when running at the above velocity. This width is used to calculate density for the above roll weight. 7. TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION OR DIAGNOSTIC Screen blank or hard to read Contrast misadjusted Power select switch improperly set. Press SHIFT, B and or to adjust. Set 115/230 vac power select switch to the appropriate voltage. Output always low Output always high Cannot enter PROGRAM, CALIBRATE, BASIC )EXCESSIVE ROLL WEIGHT( TENSION ON/OFF set to OFF E-STOP is active (except unwind). E-STOP is wired incorrectly. JP8-7 not set for the proper logic supply. E-STOP is active (unwinds only). E-STOP is wired incorrectly. JP8-7 not set for the proper logic supply. Not in HOLD mode: RUN/STOP not wired correctly. JP8-7 not set for the proper logic supply. Sensor(s) misapplied If REMOTE TENSION ON/OFF is set to )TOGGLE( press TENSION ON/OFF on the keypad once. If REMOTE TENSION ON/OFF is set to )LEVEL( one or more of the remote tension off switches are closed. If the internal logic is being used (the factory default) TB4.2 must be connected to TB4.1 to disable E-STOP. Also verify JP8-7 set to )INT(. If an external logic supply is used see Section 6.5. See above. If the internal logic supply is being used (the factory default) TB4.4 must be connected to TB4.3 to be in HOLD mode. Also verify JP8-7 set to )INT(. If an external logic supply is used see Section 6.5. The total weight of the sensor idler roll and shaft must be less than of sensor rating. When two sensors are used this is the combined rating of both (i.e. 100 lbs for two 50 lb sensors).

13 )MAXIMUM TENSION TOO HIGH( )SENSOR SIGNAL TOO LOW( Selected maximum tension is out of sensor range. Maximum tension is out of sensor range. Calibration can be completed by using a smaller maximum tension. See )Maximum tension is out of range( below. 1. This problem is often caused by loading the sensor in the wrong direction. It can be corrected by reversing +SIG and -SIG (TB2-1 and TB2-2). 2. If signal direction is correct, calibration can often be completed by using a larger maximum tension. See )Maximum tension is out of range( below. Maximum tension is out of sensor range. When maximum tension is applied the load on the sensors must be less than the total sensor rating and greater than 1/8 of total sensor rating. When two sensors are used this is the combined rating of both (i.e. 100 lbs for two 50 lbs sensors). Calculate this load from: LOAD = 2*MAX*SIN(WRAP/2) where: MAX = maximum tension entered during sensor calibration. WRAP=wrap angle. Tension oscillates DIAGNOSTIC: 1. From the home screen use NEXT or PRIOR to go to OUTPUT LEVEL. 2. While the machine is running record the approximate output level. 3. Enter this value in the MANUAL LEVEL. 4. Switch to MANUAL mode. 5. If the tension continues to oscillate there is an out of round roll or other machine generated tension variation. 6. If oscillation stops the control may be mistuned. See ERROR LIM needs adjustment. ERROR LIM needs adjustment 1. Go to OPTIMIZE ERROR LIM. 2. Press and hold until the oscillation stops. If ERROR LIM is max go to )COMP needs adjustment(. COMP needs adjustment 1. Go to OPTIMIZE COMP (ignore reference to core). 2. Press and hold until the oscillation stops. 3. If oscillations cease, optimize ERROR LIMIT. 3. If COMP is max go to )STAB needs adjustment(.

14 Tension oscillates (continued) STAB needs adjustment 1. Go to OPTIMIZE STAB (ignore reference to full roll). 2. Press and hold until the oscillation stops. 3. If oscillations cease, optimize COMP and then optimize ERROR LIM. 4. If STAB is max go to )STAB is max(. Tension oscillates (continued) STAB is max This is extremely rare. You have a system that needs more than a 150 sec integrator to be stable. Verify this result by performing the diagnostic under )Tension oscillates(. If verified this system may need to use PID for the OPTIMIZE METHOD. Consult the factory. Front panel TENSION ON/OFF does not work Cannot change to a different setup DIGITRAC 2 configured for LEVEL for external TENSION ON/OFF E-STOP is active E-STOP is wired incorrectly JP8-7 not set for the proper logic supply. Not in HOLD mode RUN/STOP not wired correctly JP8-7 not set for the proper logic supply When LEVEL is selected for TENSION ON/OFF only external tension on/off can be used. If the internal logic is being used (the factory default) TB4.2 must be connected to TB4.1 to disable E-STOP. Also verify JP8-7 set to )INT(. If an external logic supply is used see Section 6.7. If the internal logic supply is being used (the factory default) TB4.4 must be connected to TB4.3 to be in HOLD mode. Also verify JP8-7 set to )INT(. If an external logic supply is used see Section

15 8. RESET PROCEDURES If it is desired to reset parameters to factory default values perform one of the following reset procedures: A. 1. Simultaneously press and and hold for 2 seconds. )RESETTING PARAMETERS( will appear on the screen for 1 second. 2. Program reset is complete. The basic (tension sensor) calibration is still in memory, but dynamic calibration must be reprogrammed. or B. 1. Connect TB4.6 to TB4.3 for 2 seconds. 2. When )REMOVE FORMAT SIGNAL TO START( appears, remove connection. 3. Program reset is complete. The basic (tension sensor) calibration is still in memory, but dynamic calibration must be reprogrammed. or C. 1. Turn the power to the DIGITRAC 2 )OFF( for 5 seconds. 2. Press SHIFT and 3 simultaneously. 3. While holding the keys down, turn the power )ON(. 4. Release both keys when the screen appears. The screen will display )TEST OR NORMAL? TEST( 5. Press ENTER to display )DISABLE WATCHDOG NO( 6. Press PRIOR ITEM to display )TEST OR NORMAL? TEST( 7. Press to display )TEST OR NORMAL? NORMAL( 8. Press ENTER. 9. Program reset is complete. The basic (tension sensor) calibration has been erased, and all other programming has been reset to factory default values. Begin at Section 4 to reprogram. 15

16 16

17 17

18 18

19 19

20 DIGITRAC % 2 Specifications Supply Voltage 115 or 230 volts rms, 10% Supply Frequency: 50 or 60 cycles per second, sinusoidal Fuses: F1, F2 1.6 amp, Littelfuse Part No , or Wickmann Part No FS Enclosure D2 Front Panel IP65 (IEC529) D2E Enclosure IP20 (IEC529) IP65 (IEC529) Climatic Class: 3K3 (EN60721) Temperature Range: Operating 0-C to 40-C Storage -30-C to +80-C Relative Humidity 5% to 85% Pollution Degree: 2 (IEC664-1) Altitude: 0 to 2000 m Compatible Residual Current Devise Types: Worst Case Fault Current: A or B (IEC755) 1.6 amp Inputs: Tension Sensor Diameter Web Speed E-Stop Run/Stop Tension Off Format Outputs: Torque Tension Reference 2.1 mvdc using +5 and -5 vdc (10 vdc) across one 350 ohm sensor or two 350 ohm sensors in parallel, or 100 mvdc, using 5 volts across one 100 ohm full bridge, or 0 to +10 vdc analog 0 to +10 vdc analog, or 20 to 10,000 pulses per second, 5 volt TTL 0 to +10 volts analog, or 20 to 10,000 pulses per second, 5 volt TTL switch closure or 5 vdc or 24 vdc logic switch closure or 5 vdc or 24 vdc logic switch closure or 5 vdc or 24 vdc logic switch closure or 5 vdc or 24 vdct logic 0 to +10 vdc., 1 madc maximum 4 to 20 madc, 500 ohms maximum -10 to +10 vdc, 1 madc maximum 0 to +5 vdc., 1 madc maximum 20

21

22

EZ-TRAC Digital Tension Readout and Control

EZ-TRAC Digital Tension Readout and Control Magnetic Power Systems, Inc. 1626 Manufacturers Drive. Fenton, MO 63026 Tel: 636.343.5550 Fax: 636.326.0608 magpowr@magpowr.com INSTRUCTION MANUAL EZ-TRAC Digital Tension Readout and Control Table of Contents

More information

MAGPOWR Spyder-Plus-S1 Tension Control

MAGPOWR Spyder-Plus-S1 Tension Control MAGPOWR TENSION CONTROL MAGPOWR Spyder-Plus-S1 Tension Control Instruction Manual Figure 1 EN MI 850A351 1 A COPYRIGHT All of the information herein is the exclusive proprietary property of Maxcess International,

More information

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY 222 W. Memorial Road, Oklahoma City, OK 73114-2317 Phone: 1-800-624-7697 Fax: 405-755-8425 www.magpowr.com E-mail: magpowr@magpowr.com INSTRUCTION MANUAL MODEL PS-24 24 VDC POWER SUPPLY All of the information

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

TRAC-3 TENSION READOUT AND CONTROL

TRAC-3 TENSION READOUT AND CONTROL Magnetic Power Systems, Inc. 1626 Manufacturers Drive. Fenton, MO 63026 Tel: 636.343.5550 Fax: 636.326.0608 magpowr@magpowr.com INSTRUCTION MANUAL TRAC-3 READOUT AND CONTROL For Control of Magnetic Particle

More information

CYGNUS TM DIGITAL TENSION READOUT AND CONTROL

CYGNUS TM DIGITAL TENSION READOUT AND CONTROL Magnetic Power Systems, Inc. 1626 Manufacturers Drive. Fenton, MO 63026 Tel: 636.343.5550 Fax: 636.326.0608 magpowr@magpowr.com INSTRUCTION MANUAL CYGNUS TM DIGITAL TENSION READOUT AND CONTROL CYGNUS-E

More information

Fincor Series 2230 MKII/2240

Fincor Series 2230 MKII/2240 Fincor Series 2230 MKII/ Fincor Series 2200 regenerative drives are ideal for your more demanding applications. They feature flexibility with ratings up to 5 horsepower. The Series 2230 MKII offers new

More information

Continental Hydraulics Installation Manual CEM-AA-A

Continental Hydraulics Installation Manual CEM-AA-A Continental Hydraulics Installation Manual CEM-AA-A Description: This power amplifier drives either single or dual solenoid proportional valve coils up to 2.6A. It is suitable to control current to proportional

More information

CPW Current Programmed Winder for the 890. Application Handbook. Copyright 2005 by Parker SSD Drives, Inc.

CPW Current Programmed Winder for the 890. Application Handbook. Copyright 2005 by Parker SSD Drives, Inc. CPW Current Programmed Winder for the 890. Application Handbook Copyright 2005 by Parker SSD Drives, Inc. All rights strictly reserved. No part of this document may be stored in a retrieval system, or

More information

Loadcell Tension Control

Loadcell Tension Control CORTEX INDUSTRIAL SYSTEM CONTROLLER Loadcell Tension Control Instruction Manual Model CORTEX-D00 Table of Contents 1. General Description... 2 2. Specifications... 3 2.1 Electrical... 3 2.2 Physical...

More information

Original Instructions INSTRUCTION MANUAL Model GTSCM / GTSDM Load Cells For Under Pillow Block Applications

Original Instructions INSTRUCTION MANUAL Model GTSCM / GTSDM Load Cells For Under Pillow Block Applications Original Instructions INSTRUCTION MANUAL Model GTSCM / GTSDM Load Cells For Under Pillow Block Applications All of the information herein is the exclusive proprietary property of Maxcess International,

More information

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI II 1400-6 ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI ACSI 1426-04-AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1092, REV. C INSTALLATION For C-UL Listed applications,

More information

5001TCP SPEED CONTROLLER

5001TCP SPEED CONTROLLER VARIABLE SPEED DRIVE CONTROLLER INSTALLATION AND SETTING UP MANUAL 5001TCP SPEED CONTROLLER With PC101 Torque Limit Control WARNING Disconnect all incoming power before working on this equipment. Follow

More information

MAGPOWR DLCA Digital Load Cell Amplifier

MAGPOWR DLCA Digital Load Cell Amplifier MAGPOWR TENSION CONTROL MAGPOWR DLCA Digital Load Cell Amplifier Installation and User Manual EN MI 850A348 1 D CONTENTS INTRODUCTION 1-1 About these operating instructions... 1-1 Product overview... 1-2

More information

MAGPOWR DTR-65 Digital Load Cell Amplifier

MAGPOWR DTR-65 Digital Load Cell Amplifier MAGPOWR TENSION CONTROL MAGPOWR DTR-65 Digital Load Cell Amplifier Installation and User Manual EN MI 850A349 1 CONTENTS INTRODUCTION 1-1 About these operating instructions... 1-1 Product overview... 1-2

More information

Induction Power Supplies

Induction Power Supplies Induction Power Supplies 7.5kW; 135 400kHz 480V version (Integral Heat Station) User s Guide Model 7.5-135/400-3-480 SMD Control Brds Rev. D 5/08 Table of Contents 1. Specifications and features...3 2.

More information

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2 RCP200 Series Motor Controls Instruction Manual Model RCP202-000 Model RCP205-000 Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2 You ve just purchased the best! Congratulations! You ve just purchased

More information

5001TCP SPEED CONTROLLER

5001TCP SPEED CONTROLLER INSTALLATION AND SETTING UP MANUAL 5001TCP SPEED CONTROLLER WARNING Disconnect all incoming power before working on this equipment. Follow power lockout procedures. Use extreme caution around electrical

More information

S4 Controller OPERATOR S HANDBOOK. Montalvo. Operator s Handbook

S4 Controller OPERATOR S HANDBOOK. Montalvo. Operator s Handbook Operator s Handbook Version 1.0 / Pub. Date 091211 / v1 Technical details subject to change without notice. -operator handbook-us Montalvo Table of Contents 1 General Description... 2 2 Front Panel...

More information

DC Variable Speed Drive Panel

DC Variable Speed Drive Panel DC Variable Speed Drive Panel Installation, Operation & Maintenance Instruction Manual Bulletin #: CC-IOM-0103-D Manufacturers of Quality Pumps, Controls and Systems ENGINEERED PUMP OPERATIONS 2883 Brighton

More information

OPERATOR TROUBLESHOOTING GUIDE

OPERATOR TROUBLESHOOTING GUIDE OPERATOR TROUBLESHOOTING GUIDE ABOUT THE TROUBLESHOOTING GUIDE This document is provided for the use of qualified operator installers. The installer should familiarize themselves with this guide Options

More information

CONTROL FEATURES AVAILABLE OPTIONS

CONTROL FEATURES AVAILABLE OPTIONS Vari Speed A2000 TABLE OF CONTENTS Control Features Options Application Data Operating Condition s Control Ratings Chart Mounting Dimensions Installation and Wiring Typical Wiring Diagram Schematic (Block

More information

1/6 through 5 HP Adjustable Speed, DC Motor Controllers

1/6 through 5 HP Adjustable Speed, DC Motor Controllers 1/6 through 5 HP Adjustable Speed, DC Motor Controllers 1/6-5 HP 115 or 230 V, Single Phase - Reconnectable Four Quadrant Regenerative Selectable Deadband AC Line Starting DC Tachometer Feedback Run Contact

More information

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320 Inlet Controller SB 2000 USER'S MANUAL AUTO OPEN MANUAL PUSH TO SEARCH NEXT STAG E CLOSE Aerotech, Inc. FORM: QM 1320 4215 Legion Dr. Mason, MI 48854-1036 USA Rev. 3, Sept. 1997 Ph. (517) 676-7070 Fax

More information

CENTRIFEEDER ELECTRONICS

CENTRIFEEDER ELECTRONICS CENTRIFEEDER ELECTRONICS FOR USE WITH CENTRIFEEDER with Integrated Vibratory Control REV 08/13 ADDENDUM VERSION 6.22 SOFTWARE Copyright 2011 Eastern Instrument Laboratories, Inc. All Rights Reserved. TABLE

More information

Signet Temperature Transmitter

Signet Temperature Transmitter Signet 80 Temperature English 80.090 80.090 Rev. G /0 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents.

More information

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors Made in the U.S.A. NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors Nema Enclosed DC Control Specifications Catalog Number BC140 or Features BC138 BC139 BC140-FBR BC154 BC160 BCWD140

More information

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN Form 1254 BRAKETRON Electronic Motor Brake Instructions SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN TABLE OF CONTENTS SECTION TITLE PAGE I. Introduction 1 II. Specifications 1 III. Principles

More information

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible DC Drives Flexible & Powerful single-phase DC drives provide a complete family solution from the compact Series 2120 chassis drive to the powerful Series 2230 and it s feature rich application specific

More information

Overvoltage Suppression F7 Drive Software Technical Manual

Overvoltage Suppression F7 Drive Software Technical Manual Overvoltage Suppression F7 Drive Software Technical Manual Software Number: VSF11015X, Drive Models: CIMR-F7UXXXXXX-062, CIMR-F7U40750F-145. Document Number: TM.F7SW.062, Date: 09/17/2010, Rev: 10-09 This

More information

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00 Inlet Controller TC5-ITA USER'S MANUAL M 890-00047 rev. 02 K 895-00458 rev. 00 TABLE OF CONTENTS PRECAUTIONS... 3 FEATURES... 4 LOCATION OF THE CONTROLS... 5 Status Leds...5 Internal Switches...6 INSTALLATION

More information

OnCommand Troubleshooting Guide Hayward Industries

OnCommand Troubleshooting Guide Hayward Industries OnCommand Troubleshooting Guide 2010 Hayward Industries Table of Contents Safety Precautions Page 1 Overview Pages 2-5 Software Troubleshooting Page 6 Local Display Pages 7-8 Relays Pages 9-10 Heaters

More information

ESD5500E Series Speed Control Unit

ESD5500E Series Speed Control Unit ESD5500E Series Speed Control Unit 1 SPECIFICATIONS INTRODUCTION PERFORMANCE Isochronous Operation ± 0.25% or better Speed Range / Governor 1-7.5 KHz Continuous Speed Drift with Temperature ±1% Maximum

More information

Mitsubishi. VFD Manuals

Mitsubishi. VFD Manuals Mitsubishi VFD Manuals Mitsubishi D700 VFD Installation Mitsubishi FR-D700 VFD User Manual Mitsubishi D700 Parallel Braking Resistors VFD Wiring Diagram - Apollo Mitsubishi VFD to Interpreter Mitsubishi

More information

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR TECHNICAL MANUAL MODEL DVR 2000 AND DVR 2000C FIGURE 1 - FRONT AND REAR VIEW OF VOLTAGE REGULATOR...4 SECTION 1- INTRODUCTION...5 GENERAL DESCRIPTION...5 SPECIFICATIONS...5

More information

STEADYWEB TENSION CONTROLLER Data Sheet

STEADYWEB TENSION CONTROLLER Data Sheet STEADYWEB TENSI CTROLLER Data Sheet Dover offers a variety of analog SteadyWeb tension controllers. They are used to operate pneumatic or electric brakes and clutches, eddy current clutches, and DC and

More information

DUAL SWIVEL REEL OPERATING INSTRUCTIONS

DUAL SWIVEL REEL OPERATING INSTRUCTIONS DUAL SWIVEL REEL OPERATING INSTRUCTIONS MODELS 100 & 1000 SERIES RAPID-AIR CORPORATION 4601 KISHWAUKEE ST. ROCKFORD, IL 61109-2925 Phone: (815) 397-2578 Fax: (815) 398-3887 Web Site: www.rapidair.com OPERATING

More information

Magnetek DSD 412 Drive

Magnetek DSD 412 Drive DRIVE STARTUP MANUAL Magnetek DSD 412 Drive Induction Motor Installation www.smartrise.us 2601 Fair Oaks Blvd., Sacramento, CA 95864 916.457.5129 Magnetek DSD 412 Drive EQUIPMENT/SETTINGS VERIFICATION

More information

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

CENTROIDTM. AC Brushless Drive. Product Spec Sheet 4 Axis, up to 2 KW motors Brake Output for each axis Overtemp and Overcurrent Protection All-software Configuration Self-cooled Fiber Optic Control CENTROIDTM AC Brushless Drive Product Spec Sheet AC Brushless

More information

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech The Axpert-CSS is a range of Combination Soft Starter panels offered by AMTECH DRIVES. We also offer the module unit as an individual product, named as Axpert-Opti torque Soft Starter. This is only the

More information

STR3. Step Motor Drive. User Manual

STR3. Step Motor Drive. User Manual STR3 Step Motor Drive User Manual Contents 1 Introduction... 3 1.1 Overview... 3 1.2 Features... 3 1.3 Block Diagram... 4 1.4 Safety Instructions... 5 2 Getting Started... 6 2.1 Mounting Hardware... 6

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 80 Pressure 80.090 80.090 Rev. J 0/ English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents. Installation.

More information

MAGPOWR TENSION CONTROL SOLUTIONS MAGPOWR TENSION CONTROL SOLUTIONS. Advanced Web Tension and Torque Control Technologies

MAGPOWR TENSION CONTROL SOLUTIONS MAGPOWR TENSION CONTROL SOLUTIONS. Advanced Web Tension and Torque Control Technologies MAGPOWR TENSION CONTROL SOLUTIONS MAGPOWR TENSION CONTROL SOLUTIONS Advanced Web Tension and Control Technologies INTRODUCTION 1 High quality and efficiency are the goals of every web production line,

More information

VFD - Mitsubishi. VFD Manuals. Mitsubishi D700 VFD Installation. Mitsubishi FR-D700 VFD User Manual. Mitsubishi D700 Parallel Braking Resistors

VFD - Mitsubishi. VFD Manuals. Mitsubishi D700 VFD Installation. Mitsubishi FR-D700 VFD User Manual. Mitsubishi D700 Parallel Braking Resistors VFD - Mitsubishi VFD Manuals Mitsubishi D700 VFD Installation Mitsubishi FR-D700 VFD User Manual Mitsubishi D700 Parallel Braking Resistors VFD Wiring Diagram - Apollo Mitsubishi VFD to Interpreter Mitsubishi

More information

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved. MANUAL ECM Motor ECM / ECM-DX Series v100 Issue Date: 08/15/17 2017 Price Industries Limited. All rights reserved. ECM MOTOR TABLE OF CONTENTS ECM Motor Background...1 ECM Motor Power and Control Connectors...2

More information

Boston Gear Ratiotrol

Boston Gear Ratiotrol Boston Gear Ratiotrol DC Motor Speed Control Installation and Operation Doc. No. 3721 RG1 and RG2 Models 1/6-1 HP GENERAL INFORMATION DESCRIPTION Series RG Controllers statically convert single-phase AC

More information

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module. Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module. 1 Upon the completion of this module, you will be able to describe the

More information

1.0 Features and Description

1.0 Features and Description 1.0 Features and Description The is an intelligent actuator designed for precise control of quarter turn valves and dampers. Using stepper motor technology, the SmartStep proportionally positions valves

More information

Dynaweb, Inc. EP350 Dancer Tension Controller. Instruction Manual

Dynaweb, Inc. EP350 Dancer Tension Controller. Instruction Manual Dynaweb, Inc. EP350 Dancer Tension Controller Instruction Manual 1 DYNAWEB, INC July 1, 2010 Page# INSTALLATION 2 START-UP, POWER OFF, NO WEB 2 START-UP, POWER ON, NO WEB 3 START-UP, POWER ON, WEB UP MACHINE

More information

Installation & Operation Manual

Installation & Operation Manual Installation & Operation Manual SECO SE 2000 Series DC Motor Controller 1 Through 5 HP 115/230 VAC 1 Phase Input TABLE OF CONTENTS Section Page 1.0 GENERAL INFORMATION... 3 1.1 Controller... 4 1.2 Specifications...

More information

Signet Pressure Transmitter

Signet Pressure Transmitter Signet 8450 Pressure English 8450.090 8450.090 Rev. G /06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury. Contents

More information

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM DSE 520 ISSUE 4 4/4/02 MR 1 TABLE OF CONTENTS Section Page INTRODUCTION... 4 CLARIFICATION OF NOTATION USED WITHIN THIS PUBLICATION.... 4 1. OPERATION...

More information

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA MDCKB1-120081-01 110VAC, 8A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information

DENISON HYDRAULICS Jupiter 500 Driver Card Series S

DENISON HYDRAULICS Jupiter 500 Driver Card Series S Back to Content DENISON HYDRAULICS Jupiter 500 Driver Card Series S20-11712-0 Publ. 9-AM681 E-Mail: denison@denisonhydraulics.com Internet: http://www.denisonhydraulics.com SYSTEM FEATURES SYSTEM FEATURES

More information

Tension Control System MCS-166, MCS-203, MCS-204

Tension Control System MCS-166, MCS-203, MCS-204 Tension Control System MCS-166, MCS-203, MCS-204 P-257-WE 819-9027 Installation & Operation Instructions An Altra Industrial Motion Company Table of Contents Introduction...3 Specifications... 3-4 Installation

More information

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951) SPI Mag MODEL 282L SINGLE POINT INSERTION ELECTROMAGNETIC FLOW METER 2 SENSOR SUBMITTAL PACKAGE From McCROMETER, INC. 3255 WEST STETSON AVENUE HEMET, CA 92545 Phone (951) 652-6811 Toll Free (800) 220-2279

More information

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-10 ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Up to 1.95 Amps Load Capacity Class 2 Rated Outputs Overload, Over Voltage, and Short Circuit Protection Standby Battery

More information

EG3000. Generator Electronic Governor Controller Operation Manual

EG3000. Generator Electronic Governor Controller Operation Manual EG3000 Generator Electronic Governor Controller Operation Manual Smoke Limit Control, Idle Speed Control, suitable for Builtin, Non-Built-in and PT Pump Type Actuator. SP POWERWORLD LTD Willows, Waterside,

More information

EDG5500 Electronic Digital Governor With Quikset Display

EDG5500 Electronic Digital Governor With Quikset Display 1 INTRODUCTION EDG5500 Electronic Digital Governor With Quikset Display GAC s EDG5500 digital governor is designed to regulate engine speed on diesel and gaseous-fueled engines. The EDG system is a suitable

More information

Filtered PWM Speed Control for Permanent Magnet DC Motors

Filtered PWM Speed Control for Permanent Magnet DC Motors Instructions for Installation and Operation Filtered PWM Speed Control for Permanent Magnet DC Motors Model 0794 Speed and Direction Control up to 5/8 HP NEMA-1/IP-20 Specifications Product Type:... WPM-2148E1

More information

MDC VAC, 15A Brushless Controller. User s Guide. 910 East Orangefair Lane, Anaheim, CA

MDC VAC, 15A Brushless Controller. User s Guide. 910 East Orangefair Lane, Anaheim, CA MDC150-120151 120VAC, 15A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information

ESC2301. Universal Electronic Governor Controller Operation Manual

ESC2301. Universal Electronic Governor Controller Operation Manual ESC2301 Universal Electronic Governor Controller Operation Manual *Replaces most Woodward, Barber Colman & Cummins Speed Controls Features Smoke Limit Control, Idle Speed Control, 12V or 24V input Suitable

More information

CS 420RC. Solid De-icer Controller Configuration and Set-up Manual

CS 420RC. Solid De-icer Controller Configuration and Set-up Manual CS 420RC Solid De-icer Controller Configuration and Set-up Manual 2/15 Table of Contents 1 Systems Modes of Operation 3 2 System Features 4 3 System Description 5 4 System Specifications 6 4.1 CS-420RC

More information

PowerView PV380-R2 Mechanical Configuration

PowerView PV380-R2 Mechanical Configuration PowerView PV380-R2 Mechanical Configuration Operations Manual *Products covered in this document comply with European Council electromagnetic compatibility directive 2004/108/EC and electrical safety directive

More information

Product Manual (Revision A, 8/2015) Original Instructions. ProAct II Digital Speed Control System. Technical Supplement

Product Manual (Revision A, 8/2015) Original Instructions. ProAct II Digital Speed Control System. Technical Supplement Product Manual 36060 (Revision A, 8/2015) Original Instructions ProAct II Digital Speed Control System Technical Supplement DEFINITIONS This is the safety alert symbol. It is used to alert you to potential

More information

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc. POWER SUPPLY MODEL XP-800 TWO AC VARIABLE VOLTAGES; 0-120V and 0-40V @ 7A, PLUS 0-28VDC @ UP TO 10A Instruction Manual Elenco Electronics, Inc. Copyright 1991 Elenco Electronics, Inc. Revised 2002 REV-I

More information

INSTALLING, OPERATING AND MAINTAINING THE MODEL D1028 COMPUTER INPUT BI-DIRECTIONAL GENERATOR FIELD REGULATOR INSTRUCTION MANUAL # S-225

INSTALLING, OPERATING AND MAINTAINING THE MODEL D1028 COMPUTER INPUT BI-DIRECTIONAL GENERATOR FIELD REGULATOR INSTRUCTION MANUAL # S-225 INSTALLING, OPERATING AND MAINTAINING THE MODEL D1028 COMPUTER INPUT BI-DIRECTIONAL GENERATOR FIELD REGULATOR INSTRUCTION MANUAL # S-225 INSTALLING, OPERATING AND MAINTAINING THE MODEL D1028 BI-DIRECTIONAL

More information

SIGNET Temperature Transmitter

SIGNET Temperature Transmitter SIGNET 83501 Temperature *38350.0901* English 38350.0901 Rev. G 3/06 English CAUTION! Remove power to unit before wiring input and output connections. Follow instructions carefully to avoid personal injury.

More information

MAGPOWR TENSION CONTROL SOLUTIONS MAGPOWR TENSION CONTROL SOLUTIONS. Advanced Web Tension and Torque Control Technologies

MAGPOWR TENSION CONTROL SOLUTIONS MAGPOWR TENSION CONTROL SOLUTIONS. Advanced Web Tension and Torque Control Technologies MAGPOWR TENSION CONTROL SOLUTIONS MAGPOWR TENSION CONTROL SOLUTIONS Advanced Web Tension and Control Technologies INTRODUCTION 1 High quality and efficiency are the goals of every web production line,

More information

MDC Series

MDC Series MDC300-120151 Series 120VAC, 15A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714)

More information

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

User Manual. T6 Tachometer. Online:   Telephone: P.O. Box St. Petersburg, Florida 33736 User Manual T6 Tachometer Online: www.phareselectronics.com Telephone: 727-623-0894 P.O. Box 67251 St. Petersburg, Florida 33736 Table of Contents Overview... 1 Description... 1 Wiring... 1 T6 Tachometer

More information

GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS. User s Manual

GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS. User s Manual GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS User s Manual Safety Warnings SHOCK HAZARD AVOID HEAT KEEP DRY AVOID VIBRATION This symbol denotes an important safety tip or warning. Please

More information

G203V / G213V MANUAL STEP MOTOR DRIVE

G203V / G213V MANUAL STEP MOTOR DRIVE G203V / G213V MANUAL STEP MOTOR DRIVE PRODUCT DIMENSIONS PHYSICAL AND ELECTRICAL RATINGS Minimum Maximum Units Supply Voltage 18 80 VDC Motor Current 0 7 A Power Dissipation 1 13 W Short Circuit Trip 10

More information

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA MDC150-012301 12V, 30A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 910 East Orangefair Lane, Anaheim, CA 92801 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual Headquarters : No.3, Lane 201, Chien Fu St., Chyan Jenn Dist., Kaohsiung, TAIWAN Tel : + 886-7-8121771 Fax : + 886-7-8121775 URL : http://www.kutai.com.tw

More information

MaxPak Plus Analog DC V S Drive

MaxPak Plus Analog DC V S Drive Three-Phase 3-600 HP non-regenerative and 5-150 HP regenerative drives Designed to accommodate a wide range of industrial requirements, the DC V S Drive has been widely applied worldwide. Selected ratings

More information

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Dycon D2430 EN54-4 Fire Alarm Power Supply Series Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product

More information

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter

Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter Intelli-Feed Controller User s Manual Intelli-Feed Digital Tachometer and Hourmeter Part #: 9047 Table of Contents: Table of Contents 2 Intelli-Feed TM User Interface 3 Equipment Diagnostic Indicators

More information

FAIRCHILD T5420 DIGITAL-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

FAIRCHILD T5420 DIGITAL-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions FAIRCHILD T5420 DIGITAL-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions Figure 1. T5420 Outline Dimensions. INSTALLATION The Model T5420 can be mounted directly onto a flat surface

More information

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL Model No. DFC-X Support 877-351-4702 DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL This manual covers the following products: DFC-X TS-01 DFTD RDU DAT-12 PWM-10V

More information

Product Guide: Series III Pump Control Board Set (RoHS)

Product Guide: Series III Pump Control Board Set (RoHS) revised 04/08/10 Description: The Series III Pump Control Board Set provides motor drive and pump control for a wide assortment of pumps from Scientific Systems, Inc. The assembly consists of two circuit

More information

PRODUCT SERIES: DPG-2100

PRODUCT SERIES: DPG-2100 Service Information PRODUCT SERIES: DPG-2100 DYNA Programmable Governor for Isochronous Generators Calibration and Troubleshooting for DPG-2101, DPG-2102, DPG-2103, DPG-2104 DPG-2100 The DPG-2100 governors

More information

Inlet Controller SB3500 USER'S MANUAL

Inlet Controller SB3500 USER'S MANUAL Inlet Controller USER'S MANUAL NOTICE Every effort has been made to ensure that this manual is complete, accurate and up-to-date. The information contained in it is however subject to change without notice

More information

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / / Non-Regen Drives Non-regenerative drives are typically used on applications which primarily motor in one direction and stopping is achieved through friction or infrequent use of a dynamic braking resistor.

More information

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. Introduction OPERATING INSTRUCTIONS: MCD REMOTE OPERATOR Order Codes: 175G94 (for MCD 2) 175G361 + 175G9 (for MCD 5) 175G361 (for MCD 3) 1. Introduction 1.1. Important User Information Observe all necessary

More information

2904 Power Supply Installation Instructions I-EA00041

2904 Power Supply Installation Instructions I-EA00041 FEATURES Controls an opening with electrified locking device and automatic door operator Separate inputs for activation switch on entry and exit sides of opening Separate 24 VDC outputs for fail safe and

More information

LNII Series Motor and Drives

LNII Series Motor and Drives LNII Series Motor and Drives Operator's Manual PN 04-01805 B PRECISION MOTION CONTROLS 2530 Berryessa Rd. #209 San Jose, CA 95132 10/04/05 2 2 LNII Manual Table of Contents Page Introduction 1. Description

More information

ACSI MODEL POWER SUPPLY INSTALLATION INSTRUCTIONS

ACSI MODEL POWER SUPPLY INSTALLATION INSTRUCTIONS II 1400-9 ACSI MODEL 1400-6100 POWER SUPPLY INSTALLATION INSTRUCTIONS Features: Used exclusively with the ACSI Series 6100 Communicating Bath Door (Common Bath) System Two separate and identical rows of

More information

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document. General information Actuator controls AC 01.2 for controlling multi-turn actuators of the SA/SAR type range and part-turn actuators of the SQ/SQR.2 type range. Features and functions Power supply Standard

More information

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16 User Manual CLA-VAL Europe www.cla-val.ch cla-val@cla-val.ch 1 - LIN072UE - 04/16 Table of Contents 1 Introduction... 3 1.1 Precautions Before Starting... 3 1.2 Troubleshooting... 3 1.3 General Disclaimer...

More information

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen. Kelly HSR Opto-Isolated Series Motor Controller with Regen User s Manual HSR72601 HSR72801 HSR12401 HSR12601 HSR12901 HSR14301 HSR14501 HSR14701 Rev.3.3 Dec. 2011 Contents Chapter 1 Introduction... 2 1.1

More information

HGM-MZ Multi-Zone Monitor Annual Maintenance And Troubleshooting Guide

HGM-MZ Multi-Zone Monitor Annual Maintenance And Troubleshooting Guide HGM-MZ Multi-Zone Monitor Annual Maintenance And Troubleshooting Guide Service, Testing and Maintenance procedures BACHARACH Inc. HGM-MZ Routine Annual Maintenance And Operating Parameter Verification

More information

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries Product Data Sheet January 214 813-1-475, Rev FA Rosemount 875WA Magnetic Flowmeter System For Water and Wastewater Industries THE 875WA MAGNETIC FLOWMETER Rosemount reliability in a customized offering

More information

CABINET REEL OPERATING INSTRUCTIONS

CABINET REEL OPERATING INSTRUCTIONS CABINET REEL OPERATING INSTRUCTIONS MODELS R50, R60 & R70 SERIES RAPID-AIR CORPORATION 4601 KISHWAUKEE ST. ROCKFORD, IL 61109-2925 Phone: (815) 397-2578 Fax: (815) 398-3887 Web Site: www.rapidair.com OPERATING

More information

SERIES 2335 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-2 HP)

SERIES 2335 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-2 HP) Rev. 02/97 SERIES 2335 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-2 HP) TABLE OF CONTENTS SECTION TITLE PAGE I GENERAL INFORMATION 1 Introduction 1 General Description 1 Model Types 1 Motor

More information

TRIPS AND FAULT FINDING

TRIPS AND FAULT FINDING WWW.SDS.LTD.UK 0117 9381800 Trips and Fault Finding Chapter 6 6-1 TRIPS AND FAULT FINDING Trips What Happens when a Trip Occurs When a trip occurs, the drive s power stage is immediately disabled causing

More information

ARM V FDBK ENSURE MOTOR IS NOT ROTATING DURING POWER UP STILL FAULTS? YES ENSURE ARMATURE WIRING IS ISOLATED FROM ANY OTHER POWER LEADS STILL FAULTS?

ARM V FDBK ENSURE MOTOR IS NOT ROTATING DURING POWER UP STILL FAULTS? YES ENSURE ARMATURE WIRING IS ISOLATED FROM ANY OTHER POWER LEADS STILL FAULTS? ARM V FDBK ENSURE MOTOR IS T ROTATING DURING POWER UP This fault can only happen in the first 3 seconds after power up. The processor looks at the armature voltage. The voltage needs to be near 0. Possible

More information

Troubleshooting Bosch Proportional Valves

Troubleshooting Bosch Proportional Valves Troubleshooting Bosch Proportional Valves An Informative Webinar Developed by GPM Hydraulic Consulting, Inc. Instructed By Copyright, 2009 GPM Hydraulic Consulting, Inc. TABLE OF CONTENTS Bosch Valves

More information

SAFTRONICS DF8 PLUS SERIES

SAFTRONICS DF8 PLUS SERIES DF8 PLUS SERIES ¼ to 5 HP Full Wave Regenerative Reversing SCR Speed Controls for DC Motors CAUTION Equipment is at possibly lethal AC line voltage when AC power is connected. Pressing the STOP pushbutton

More information

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA MDCKB1-120081 120VAC, 8A Brushless Controller User s Guide A N A H E I M A U T O M A T I O N 4985 E. Landon Drive Anaheim, CA 92807 e-mail: info@anaheimautomation.com (714) 992-6990 fax: (714) 992-0471

More information