1 BART/60 Pneumatic conveyor unit Updated 01/01/2017 Integrated Air Control OPERATING MANUAL AIR-TEC SYSTEM S.r.l. via del Cerchio 3/ Calderara di Reno BOLOGNA Tel Fax

2 Pag. 2 di 36

3 INTRODUCTION The purpose of this manual is to provide the basic information necessary for using and maintaining the equipment. It is important to remember that the machine is designed and built to work exclusively with certain materials and in specific conditions. The performance you will obtain from the machine will depend on how well You have understood the contents of this manual. Improper use may cause the warranty to lapse. We strongly recommend that you carefully study this manual, the information regarding the individual components, drawings and all other documentation provided. If you diligently follow the instructions contained, we are sure you will be among the growing number of satisfied owners of Air-Tec pneumatic conveyance systems. We are committed to helping you get the most from this machine in order to enhance all your production. This manual, written by the manufacturer, is an integral part of the machine kit; It must therefore follow the car until its dismantling and be readily available for easy reference by the operators concerned and the work site. In case of change of ownership of the machine the manual must be handed over to the new owner who supplied the machine. Before doing any work with or on the machine staff concerned must absolutely and necessarily having read carefully this manual. If the manual is lost, crumpled and that they are not completely readable, you must request a new copy from manual Air-Tec System Ltd. (AIRTEC), verify that the modification date is prior to the purchase of the machine and, if not it is, go directly to AIRTEC. This manual provides warnings and indications concerning the safety regulations for the prevention of occupational accidents. Ranging however, and in any case, observed most scrupulously by the various operators safety standards laid against them by current regulations. Any modification of the safety standards that were to take place over time will have to be delivered and implemented. «CAUTION» Always keep it handy! Always observe the information! The information and illustrations in this manual were up to date edition. Pag. 3 di 36

4 AIRTEC is committed to continuous product improvement. Therefore changes in the components or the machine itself will be made without prior notice to third parties. All technical information contained herein are the exclusive property of AIRTEC. and should be considered confidential. Therefore it is prohibited its reproduction and dissemination also part without written permission. Also it is prohibited to use this manual for purposes other than those set out above. In order to detail for greater impact and clarity the operation, maintenance or other, some pictures may show the machine without protective equipment. «WARNING» IT S FORBIDDEN, LIKE STD 2014/68/UE DIRECTIVE, UTILIZE THE MACHINE WITH FLUID GROUP 1 Pag. 4 di 36

5 INDEX INTRODUCTION 3 CONVENTIONAL PNEUMATIC CONVEYANCE 7 BART INSTALLATION DIRECTIONS 8 DIMENSIONAL DRAWING 11 LAY OUT BART COMPONENTS 12 PNEUMATIC DIAGRAM SHOWING APPLICATION WITHOUT VENTING SYSTEM 13 STARTING UP AND OPERATION 14 CHECK LIST 14 BART FLUIDISATION SETTING 15 ROUTINE MAINTENANCE 16 RECOMMENDED SPARE PARTS 16 BUTTERFLY VALVE - SPARE PARTS 18 EXTRAORDINARY MAINTENANCE 20 REPLACING THE GASKET OF THE BUTTERFLY LOADING VALVE 20 IMPORTANT NOTES FOR THE COMMISSIONING 21 WORKING PRESSURE OF BART VESSEL: MAX 1,9BAR 21 NOTES TO THE PROPER INSTALLATION OF PRESSURE VESSELS 21 VESSEL CLASS A 21 VESSEL CLASS B 21 VESSEL CLASS C 21 WARRING. 21 CHANGING THE BART VENTING SYSTEM 22 BART LOADING SYSTEM VENT 22 PNEUMATIC DIAGRAM SHOWING APPLICATION WITH VENTING SYSTEM 23 ATTACHED: TECHNICAL DATA SHEET FOR INSTRUMET ON BOARD MACHINE 24 Pag. 5 di 36

6 1. RELIEF VALVE PRESSURE SWITCH LEVEL INDICATOR STANDARD VERSION AIR VALVE LOADING BUTTERFLY VALVE 30 Pag. 6 di 36

7 CONVENTIONAL PNEUMATIC CONVEYANCE The conventional pneumatic conveyance system relies on high pressure. In this specific case the pressure will be 2 bars. It is mainly recommended for conveying fine powders and granules, as well as fragile products like ceramic powder, over medium-short distances (15-30 metres max). It can also be used over longer distances but the efficiency (air/ product ratio) declines proportionally. This is a non-continuous conveyance system driven by a blow conveyor (BART). The operating cycle begins with the opening of a butterfly valve located on the top part of the BART; this allows the material to start dropping into the blow conveyor. Filling stops when the level sensor indicates that the BART has been filled to the maximum level. At this point the butterfly valve will close. When these conditions have been reached, a conveying blow valve will open to start building up the pressure inside the BART. A pressure sensor will determine when the pressure ( PS1 ) necessary for conveying the material has been reached inside the blow conveyor. The same pressure sensor also serves to close the air delivery line at the end of the conveyance cycle and allow the residual air to clean out the line. The fundamental features of this conveyance system are a high air flow at the start and end of each cycle and a lower air flow during the cycle itself. The BART pneumatic blow conveyor can convey many different kinds of materials. Both the physical characteristics of the materials and the distance they are to be conveyed have a direct influence on the machine s performance in terms of compressed air consumption and hourly capacity. Pag. 7 di 36

8 BART INSTALLATION DIRECTIONS Product inlet Product piping Connect Control Board and junction box Connect Power Supply Pag. 8 di 36

9 Supply Air actuator Connect air supply Set Convey pressure Set Fluidizing Pag. 9 di 36

10 1. It is recommended to use a compressed air storage tank with a capacity of at least 200 litres. 2. The conveyor tube, made of flexible spiral tubing or metal, must be bent into broad curves 3. The tube supplying compressed air to the pressure reducer, the pressure reducer and tube connecting the pressure reducer to the compressed air control unit must all have a diameter of 1 inch. 4. The pressure reducer must be set between 0.1 and 2 Bars 5. The maximum conveying distance is 30 metres 6. The receiving hopper must be provided with an efficient venting system to prevent the build up of counter-pressure while material is being conveyed 7. Avoid long lines with material conveyed downward 8. Use compressed air that has been dehumidified, with hygroscopic material in particular 9. The compressed air supply to the loading valve actuator and vibra-jets (where present) must be drawn upstream from the pressure reducer and must have a pressure of at least 4.5 bars to ensure that the equipment will work efficiently. The recommended value is 6 bars SIZE WEIGHT SUPPLY VOLTAGE INSTALLED POWER COMPRESSED AIR CONSUMPTION NOISE LEVEL 800x350x900 50kg 230V 50/60Hz 200VA MAX 60Nm³/h <70dBA Pag. 10 di 36

11 DIMENSIONAL DRAWING Pag. 11 di 36

12 AIR-TEC system BOLOGNA - ITALY Vessel LAY OUT BART COMPONENTS Pag. 12 di 36

13 PNEUMATIC DIAGRAM SHOWING APPLICATION WITHOUT VENTING SYSTEM Pag. 13 di 36

14 CHECK LIST STARTING UP AND OPERATION ensure scrupulous compliance with the specifications provided in the drawings of electrical and mechanical components; make sure that the mechanical components have been properly installed; compressed air supply requirements: o supply line section 1 o supply line pressure 6 bars o pressure reducer set at bars electricity supply requirements: check the wiring and voltage; check the stability of the equipment; ambient conditions suitable for operation; check and/or reset the system control parameters recorded on the display; Be sure that the characteristics of the material to be handled are compatible with the operating conditions of the and with the parameter settings. Check the correct operating of instruments on machine: o Pressure switch o Level indicator o Switch and solenoid valve For the correct functioning of level switch, it can be required a calibration procedure, to do at the start-up of machine. See the operating instruction of instruments, attached to this manual. Pag. 14 di 36

15 BART FLUIDISATION SETTING The BART blow conveyor builds up pressure by introducing compressed air through a feed manifold and through a fluidising filter located in the lower part of the conveyor. A gate valve allows the stream of compressed air to be divided between the fluidising filter and the feed manifold. The characteristics of the material will determine how the compressed air stream should be divided for optimal conveyance Powder-like materials: it is recommended to direct 75% through the fluidising filter and 25% through the compressed air feed manifold. Granular materials: a division is recommended. 100% FLUIDISING FILTER 50% FLUIDISING FILTER 50% FEED MANIFOLD Pag. 15 di 36

16 ROUTINE MAINTENANCE 1. Check the efficiency of the bottom part fitted with the fluidising filter and replace it if necessary. 2. Check the condition of the butterfly loading valve: check for wear on the gasket and disk. RECOMMENDED SPARE PARTS CODICE / CODE DESCRIZIONE / DESCIPTION 1 KB60_LIV1 KIT LEVEL STANDARD 2 KB60_LIA1 KIT LEVEL ATEX 2A KB60_LIV2 LEVEL INDICATOR HIGT TEMPERATURE 3 KBT1_PRES PRESSURE SWITCH KIT 4 KBT1_EVXX KIT SOLENOID VALVE STANDARD 5 6E SOLENOID VALVE ATEX E SOLENOID VALVE ATEX E RELIEF VALVE 8 KBT1_GRNA SEAT PLUS REPAIR KIT. BLACK GASKET 9 KBT1_GRND SEAT PLUS REPAIR KIT. WHITE GASKET 10 6K SEAT CLAMP 11 KBT1_NAM1 KIT NAMUR STANDARD 12 KBTA_NA22 KIT NAMUR ATEX KBTA_NA21 KIT NAMUR ATEX B OPERATOR KEYPAD 15 KBT1_BAL1 OPERATING BLOCK 16 6F CARBON STEEL DISC 17 6F STAINLESS STEEL DISC AISI KBT1_VA3V THREE WAYS VENT VALVE 19 6F BUTTERFLY INLET VALVE, BLACK SEAT + ACTUATOR 20 6F BUTTERFLY INLET VALVE, WHITE SEAT + ACTUATOR 21 6E PRESSURE GAUGE 22 6F EXIT VALVE IN BRASS 23 6F EXIT VALVE IN AISI F HINGES KIT DN F LIMIT SWITCH 26 6F BUTTERFLY INLET VALVE BODY CARBON STEEL 27 6F BUTTERFLY INLET VALVE BODY STAINLESS STEEL 28 KBT1_VNN1 BUTTERFLY VALVE IN CARBON STEEL WITH NAMUR VALVE 29 KBT1_VBN1 BUTTERFLY VALVE IN STAINLESS STEEK WITH NAMUR VALVE 30 6E C RELIEF VALVE atex22 Pag. 16 di 36

17 31 6E D RELIEF VALVE atex21 Pag. 17 di 36

18 BUTTERFLY VALVE - SPARE PARTS Pag. 18 di 36

19 DN 150 6F F F F F F F F F F CORPO, A105+SILICONE, ATTUATORE NO F/C BODY VALVE,A105+SILICON GASKET, ACTUATOR NO LIMIT SWITCH CORPO, A105+NBR, ATTUATORE+F/C BODY VALVE,A105+BLACK GASKET, ACTUATOR+LIMIT SWITCH CORPO, A105+NBR, ATTUATORE NO F/C BODY VALVE,A105+BLACK GASKET, ACTUATOR NO LIMIT SWITCH CORPO, AISI 316+G. NAT., ATTUATORE+F/C BODY VALVE,AISI 316+WHITE GASKET, ACTUATOR+LIMIT SWITCH CORPO, AISI 316+G. NAT., ATTUATORE NO F/C BODY VALVE,AISI 316+WHITE GASKET, ACTUATOR NO LIMIT SWITCH CORPO, AISI 316+SILICONE, ATTUATORE NO F/C BODY VALVE,AISI 316+SILICON GASKET, ACTUATOR NO LIMIT SWITCH CORPO, A105+CARBOSSILATO, ATTUATORE NO F/C BODY VALVE,A105+CARBOSSILATO GASKET, ACTUATOR NO LIMIT SWITCH CORPO, A105+NBR BODY VALVE,A105+BLACK GASKET CORPO, AISI 316+G. NATURALE BODY VALVE,AISI 316+WHITE GASKET CORPO, A105+CARBOSSILATO BODY VALVE,A105+CARBOSSILATO GASKET Pag. 19 di 36

20 EXTRAORDINARY MAINTENANCE REPLACING THE GASKET OF THE BUTTERFLY LOADING VALVE To replace the gasket correctly, carefully follow the directions below: First of all, make sure that the compressed air supply is DISABLEDAND DECOMPRESSED and that the power supply is OFF before performing any maintenance work. 1. remove the butterfly valve from the Bart blow conveyor and remove the actuator; 2. loosen and take out the screw situated on the side opposite the actuator; 3. screw an M6 bolt into the threaded hole to extract the spindle; 4. Remove the snap ring and extract the other spindle using suitable pliers. Now the disk is free and can be removed; 5. pry out the gasket by inserting a tool with a pointed tip and round edge, e.g. a screwdriver, between the gasket and the metal body of the valve; WARNING: DO NOT INSERT THE TOOL CLOSE TO THE POINT WHERE THE SHAFT PASSES THROUGH BECAUSE THIS COULD CAUSE DAMAGE TO THE SEAT DO NOT DAMAGE THE GASKET SEAT!! 6. now fit the new gasket in place, taking care to thoroughly lubricate the valve body for a smoother insertion. 7. also grease the spindles before replacing the other valve components. WARNING: BEFORE CONNECTING THE POWER SUPPLYAND INTRODUCING COMPRESSED AIR, MAKE SURE THERE ARE NO FOREIGN BODIES IN THE DISK CLOSING AREA. KEEPYOUR HANDS FAR AWAY FROM THE AREA INSIDE THE GASKET BECAUSE THE DISK MAY ROTATE SUDDENLY WHEN COMPRESSED AIR IS INTRO Pag. 20 di 36

21 IMPORTANT NOTES FOR THE COMMISSIONING WORKING PRESSURE OF BART VESSEL: MAX 1,9BAR SUPPLY MAY 'BE PROVIDED THE PRESSURE REGULATOR AT THE ENTRANCE OF THE VESSEL. NOTES TO THE PROPER INSTALLATION OF PRESSURE VESSELS VESSEL CLASS A BELONG TO THIS CATEGORY ALL CONTAINERS WITH THE PRODUCT OF VOLUME (LITRE) PRESSURE (NOT MORE THAN 12 ATE) NOT EXCEEDING THESE CONTAINERS USED INDIVIDUALLY NOT ECESSITANO VERIFICATION OF THE FIRST AND PERIODIC SYSTEM BY ORGANIZATIONS VESSEL CLASS B BELONG TO THIS CATEGORY TWO OR MORE CONTAINERS OF A CLASS SYSTEM INSTALLED IN THE SAME. THEY ARE SUBJECT ONLY TO VERIFICATION OF ORIGINAL EQUIPMENT TO BE CALLED A INAIL (EX ISPESL) OF TERRITORIAL JURISDICTION. IF YOU ARE INSTALLED WITH DEVICES CLASS C MUST BE SUBJECT TO PERIODIC CHECKS IN THIS CATEGORY. VESSEL CLASS C BELONG TO THIS CATEGORY ALL CONTAINERS WITH THE PRODUCT OF VOLUME (LITRE) PRESSURE (ATE) MORE THAN 8000 OR PRESSURE THAN 12 ATE. THEY ARE SUBJECT TO VERIFICATION OF ORIGINAL EQUIPMENT TO BE CALLED A INAIL (EX ISPESL) TERRITORIAL JURISDICTION OF THE ANNUAL AND PERIODIC CHECKS BY REGIONAL ARPA. WARRING. IN ITALY THE LAW PROVIDES THE OBLIGATION OF COMPLAINT TO BODIES IN CHARGE OF PLANTS THE SUCCESSFUL INSTALLATION CATEGORY "B" AND "C". ALSO MUST KEEP THE CERTIFICATES OF ORIGIN OF SAFETY VALVE AND THE FUEL TANK ATTACHED HERE BECAUSE' IF YOU ARE MISSING THE POSSIBILITY OF USE OF THESE IS NOT MORE AUTHORIZED BY THE AUTHORITIES RESPONSIBLE, AND BECOMES THE MANDATORY REPLACEMENT Pag. 21 di 36

22 CHANGING THE BART VENTING SYSTEM 3-way ball valve with actuator and rapid couplings for Rilsan ø8 x 1/8 Qty. 2 1 nipple Qty. 1 1 x 40 mm threaded stub pipe with 1 ring nut and 2 gaskets 1 elbow Qty. 1 1 standard gas fittings for spiral rubber tubing, outside diameter 25 mm Qty. 2 Aluminium under-base of solenoid valve complete with 2 rapid couplings for Rilsan ø8 x 1/8 ; 2 OR, outside diameter 21 mm, thickness 2 mm Bolts M5 x TCCE Qty. 2 Spiral tubing, inside diameter 25 mm L=1000 mm and 2 clamps Rilsan tube ø8 x 1500 mm -¾ flexible tubing, 600 mm BART LOADING SYSTEM VENT 1. remove the 3-piece union from the Bart 2. screw in the 3-way valve directly with a nipple and with the arrow turned toward the Bart; 3. fit the 3-piece union in the valve 4. replace the lower flexible tube with a new one 5. drill a hole in the hopper body and install the elbow with a fitting for rubber tubing 6. remove the pneumatic control valve situated above the loading valve actuator 7. place the manifold between the loading valve and the actuator with the OR turned down in contact with the body of the actuator 8. install the control valve situated above the manifold, taking care not to turn it by 180, in which case the opposite effect would be obtained 9. using the ø8 Rilsan tube provided, connect the manifold to the 3-way valve; make sure that when the loading valve is open, the inside of the Bart is connected by means of the 3-way valve and the spiral tubing is connected to the bag-emptying hopper. If this is not the case, invert the Rilsan tubes. Pag. 22 di 36

23 PNEUMATIC DIAGRAM SHOWING APPLICATION WITH VENTING SYSTEM Pag. 23 di 36

24 ATTACHED: TECHNICAL DATA SHEET FOR INSTRUMET ON BOARD MACHINE 1. RELIEF VALVE Pag. 24 di 36

25 Pag. 25 di 36 Vessel

26 2. PRESSURE SWITCH Pag. 26 di 36

27 3. LEVEL INDICATOR STANDARD VERSION Pag. 27 di 36

28 4. AIR VALVE Pag. 28 di 36

29 Pag. 29 di 36 Vessel

30 5. LOADING BUTTERFLY VALVE Pag. 30 di 36

31 Pag. 31 di 36 Vessel

32 Pag. 32 di 36

33 Pag. 33 di 36 Vessel

34 NOTE: Pag. 34 di 36

35 Pag. 35 di 36 Vessel

36 Via del Cerchio 3/ Calderara di Reno BOLOGNA ITALY Tel Fax Cod. Fisc. e Part. IVA C.C.I.A.A Iscrizione Tribunale BO Pag. 36 di 36

Operation and Maintenance Manual

Operation and Maintenance Manual BM / BMA Hydrometers ½ Operation and Maintenance Manual i This manual is intended for use by the users of this equipment. The information contained herein is the property of the Arad Ltd. Dalia and may

More information

Operating Instructions

Operating Instructions 16 1 Independent & Unauthorized Changes and Spare Parts Alterations and changes to actuators are only possible, i.e. permitted under express permission from the company airpower Europe GmbH. These conditions

More information

BELT CONVEYOR CB/M5 Series

BELT CONVEYOR CB/M5 Series BELT CONVEYOR CB/M5 Series User and maintenance manual 1 DECLARATION OF CONFORMITY The company: Tel. +39-0444 450 620-451 520 Fax +39-0444 671 840 declares under its own responsibility that the machine

More information

BELT CONVEYOR PNL/4 Series User and maintenance manual

BELT CONVEYOR PNL/4 Series User and maintenance manual BELT CONVEYOR PNL/4 Series User and maintenance manual 1 DECLARATION OF CONFORMITY CE In conformity with the 2006/42/CE Machine Directives, Enclosure II, section A The company: VIRGINIO NASTRI S.r.l. Tel.

More information

BUTTERFLY VALVE 1234P SERIES

BUTTERFLY VALVE 1234P SERIES FIGURE: AD: Pneumatic actuator, double acting AS: Pneumatic actuator, spring return ASRO: Pneumatic actuator, spring return, spring to open, air to close BUTTERFLY VALVE 1234P SERIES With pneumatic actuator

More information

MICROPUMP AIR/OIL USE AND MAINTENANCE MANUAL

MICROPUMP AIR/OIL USE AND MAINTENANCE MANUAL MICROPUMP AIR/OIL USE AND MAINTENANCE MANUAL Edition July 2012 Index GENERAL... 3 TECHNICAL CHARACTERISTIC... 3 MINIMUM LEVEL SENSOR... 3 ELECTROVALVE... 3 TYPES... 4 VERSION WITH BOX AND THANK 1.5LT...

More information

5 TANK ¾ VALVE AND 6 TANK 1 VALVE HEADER TANK SOLUTIONS PENTAIR CLEAN AIR SYSTEMS

5 TANK ¾ VALVE AND 6 TANK 1 VALVE HEADER TANK SOLUTIONS PENTAIR CLEAN AIR SYSTEMS HEADER TANK SOLUTIONS PENTAIR CLEAN AIR SYSTEMS Standard ColourRHEADER TANK SOLUTIONS DESCRIPTION The patented Mecair Full Immersion System consists of a round header tank with fully integrated diaphragm

More information

Installation and maintenance guide

Installation and maintenance guide Installation and maintenance guide DISPENSING VALVE DA 400 DAV TECH SRL Via Ravizza, 30-36075 Montecchio Maggiore (VI) - ITALY Tel. 0039 0444 574510 - Fax 0039 0444 574324 davtech@davtech.it - www.davtech.it

More information

BUTTERFLY VALVE SERIES Pneumatic actuator - El-O-Matic

BUTTERFLY VALVE SERIES Pneumatic actuator - El-O-Matic B C D BUTTERFLY VALVE - 223 SERIES Pneumatic actuator - El-O-Matic FIGURE: PD: Pneumatic actuator, double acting PE: Pneumatic actuator, spring return G F L DIMENSIONS: (mm) DN L B PD PE PD C D F Kg PE

More information

10 TANK WITH 2 VALVE HEADER TANK SOLUTIONS PENTAIR CLEAN AIR SYSTEMS

10 TANK WITH 2 VALVE HEADER TANK SOLUTIONS PENTAIR CLEAN AIR SYSTEMS HEADER TANK SOLUTIONS PENTAIR CLEAN AIR SYSTEMS Standard ColourR FULL IMMERSION SYSTEM DESCRIPTION The patented Mecair Full Immersion System consists of a round header tank with fully integrated diaphragm

More information

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP Installation, Operation, & Maintenance Manual Welker Sampler Model GSS-4HP The information in this manual has been carefully checked for accuracy and is intended to be used as a guide to operations. Correct

More information

Operating Instructions

Operating Instructions Armaturen GmbH Armaturen, Rohre, Sonderteile aus Edelstahl fittings, pipes, special parts of stainless steel Operating Instructions BaseCom butterfly valve Rev.0 / 12.12.2009 Page 1 of 8 BA52290GB.doc

More information

BUTTERFLY VALVE - N1234 SERIES Pneumatic actuator - El-O-Matic

BUTTERFLY VALVE - N1234 SERIES Pneumatic actuator - El-O-Matic B C D BUTTERFLY VALVE - N123 SERIES Pneumatic actuator - El-O-Matic FIGURE: PD: Pneumatic actuator, double acting PE: Pneumatic actuator, spring return G F L DIMENSIONS: (mm) DN L B PD PE PD C D F Kg PE

More information

VAG CEREX M300 Butterfly Valve

VAG CEREX M300 Butterfly Valve Operation and Maintenance Instructions VAG CEREX M300 Butterfly Valve KAT 1310-B Edition4 12-17 Table of Contents 1 General 3 1.1 Safety 3 1.2 Proper use 3 1.3 Identification 3 VAG reserves the right to

More information

Rectangular Door L-VAT with pneumatic actuator double acting

Rectangular Door L-VAT with pneumatic actuator double acting Rectangular Door L-VAT with pneumatic actuator double acting This manual is valid for the products: 0 7 5 1 0 U A 2 4 0 0 0 1 4 character option code Size 10... 46 x 236 12... 50 x 336 Actuator 24... without

More information

HIGH PRESSURE CONTROL VALVE PISTON BALANCED

HIGH PRESSURE CONTROL VALVE PISTON BALANCED PISTON BALANCED All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be

More information

BUTTERFLY VALVE 27 SERIES Pneumatic actuator - El-O-Matic

BUTTERFLY VALVE 27 SERIES Pneumatic actuator - El-O-Matic C D E FIGURE: PD: pneumatic actuator, double acting PE: pneumatic actuator, spring return PEO: pneumatic actuator, spring return, normally open BUTTERFLY VALVE 27 SERIES Pneumatic actuator - El-O-Matic

More information

USE AND MAINTENANCE MANUAL

USE AND MAINTENANCE MANUAL SERIES 8 Note: the numbers in parenthesis refer to the components in the exploded view of page 4 for mod. 5-30 and page 5 for mod. 70-330. VALBIA supplies a range of pneumatic rotary actuators, RACK and

More information

FASANI ASSISTED SWING CHECK VALVE BOLTED BONNET INSTALLATION AND MAINTENANCE INSTRUCTIONS

FASANI ASSISTED SWING CHECK VALVE BOLTED BONNET INSTALLATION AND MAINTENANCE INSTRUCTIONS Before installation these instructions must be fully read and understood INTRODUCTION Actuator or Counterweight assisted, flanged or welded ends. This manual provides guidelines to be observed for the

More information

original operating manual Operating manual Translation of the Item-No.: ,

original operating manual Operating manual Translation of the Item-No.: , Translation of the original operating manual Operating manual Item-No.: 015 431 551, 015 431 581 Important! Copyright The operating manual is always to be read before commissioning the equipment. No warranty

More information

Installation, Operating & Maintenance Instructions. Series 081, DN (I.D. 2½" - 4") Hot surfaces; do not touch!

Installation, Operating & Maintenance Instructions. Series 081, DN (I.D. 2½ - 4) Hot surfaces; do not touch! Vacuum Gate Valve This manual is valid for the valve ordering number(s): 08136-FA14/24/34/44 08138-FA14/24/34/44 08140-FA14/24/34/44 The fabrication number is indicated on each product as per the label

More information

USE AND MAINTENANCE MANUAL

USE AND MAINTENANCE MANUAL LATERAL TURNOVER 360 ORIGINAL INSTRUCTIONS INTRODUCTION This manual includes instructions for assembly, maintenance (regular and extraordinary), and for possible faults with remedies. The instructions

More information

Valves. Rapid opening and closing solenoid valves VMR (E1110 rev /11/2012)

Valves. Rapid opening and closing solenoid valves VMR (E1110 rev /11/2012) Valves Rapid opening and closing solenoid valves VMR (E1110 rev. 03-19/11/2012) GENERAL WARNINGS: DISPOSAL: ¾ All installation, maintenance, ignition and setting must be performed by qualified staff, respecting

More information

Installation and maintenance guide

Installation and maintenance guide Installation and maintenance guide SPRAY VALVE DAS 30 DAV TECH SRL Via Ravizza, 30-36075 Montecchio Maggiore (VI) - ITALY Tel. 0039 0444 574510 - Fax 0039 0444 574324 davtech@davtech.it - www.davtech.it

More information

USE AND MAINTENANCE MANUAL

USE AND MAINTENANCE MANUAL Note: the numbers in parenthesis refer to the components in the exploded view of page 4. VALBIA supplies a range of pneumatic rotary actuators, RACK and PINION TYPE, quarter turn, in double acting or spring

More information

INSTALLATION INSTRUCTION & TECHNICAL MANUAL FLOWMETER

INSTALLATION INSTRUCTION & TECHNICAL MANUAL FLOWMETER Sep 2003 INSTALLATION INSTRUCTION & SERIES: MICA (FL & RC) INSTALLATION INSTRUCTION & Type: MICA Series: MICA Page: INSTALLATION CONCEPT... 2 2 MOUNTING POSITION OF THE METER... 2 2. General remarks...

More information

Application cup for OptiFlex 2 GM03 manual powder gun

Application cup for OptiFlex 2 GM03 manual powder gun En Operating instructions and spare parts list Application cup for OptiFlex 2 GM03 manual powder gun Translation of the original operating instructions Documentation OptiFlex GM03 application cup Copyright

More information

Complete orbital coverage of all interior surfaces. Suitable for use in the food industry. Model Number Y Y Rated Pressure

Complete orbital coverage of all interior surfaces. Suitable for use in the food industry. Model Number Y Y Rated Pressure FEATURES Designed for quick and efficient cleaning of interior surfaces of tanks and barrels. TANK CLEANING TANK CLEANING Note: Nozzles not included SPECIFICATIONS Model Number Y25479000 Y25479100 Rated

More information

DEMCO Resilient-Seated Butterfly Valve

DEMCO Resilient-Seated Butterfly Valve Document Number: TC003001-01 Revision: Rev 2 DEMCO Resilient-Seated Butterfly Valve Installation, Operation, and Maintenance Manual TABLE OF CONTENTS BILL OF MATERIALS... 3 SCOPE... 5 NAMEPLATE INFORMATION...

More information

Installation and Setting-Up Instructions Spare Parts List

Installation and Setting-Up Instructions Spare Parts List Man.rev.2 Installation and Setting-Up Instructions Spare Parts List Contents : TECHNICAL DATA 2 CONSTRUCTION AND OPERATION 3 INSTALLATION 4 SETTING-UP 5 MAINTENANCE DOCUMENTS Technical Specifications :

More information

BELT CONVEYOR CBD/8 Series

BELT CONVEYOR CBD/8 Series BELT CONVEYOR CBD/8 Series User and maintenance manual 1 DECLARATION OF CONFORMITY CE In conformity with the 2006/42/CE Machine Directives, Enclosure II, section A The company: VIRGINIO NASTRI S.r.l. Tel.

More information

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings

Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings Product bulletin for: ST2 Ball valves with two-way and three-way BSPP threaded fittings ST2 Ball valves in conjunction with spring return and non-spring return VA-Actuators Developed for HVAC applications

More information

PNEUMATIC PUMP Series

PNEUMATIC PUMP Series PNEUMATIC PUMP Series 3103... User and Maintenance Manual Original text translation TABLE OF CONTENTS 1. INTRODUCTION 2. GENERAL DESCRIPTION 3. PRODUCT-MACHINE IDENTIFICATION 4. TECHNICAL CHARACTERISTICS

More information

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY

PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY PRESSURE REGULATOR BACK PRESSURE TO ATMOSPHERE WITH OUTSIDE SUPPLY All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been

More information

Bulk Solids Feeding. Distributor for. Blow-Through Rotary Valves RVS Drop-Through Rotary Valves RVC

Bulk Solids Feeding. Distributor for. Blow-Through Rotary Valves RVS Drop-Through Rotary Valves RVC Bulk Solids Feeding Distributor for Blow-Through Rotary Valves RVS Drop-Through Rotary Valves RVC Blow-Through Rotary Valves RVS Drop-Through Rotary Valves RVC High filling efficiency and precise metering

More information

Directional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces:

Directional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces: Directional valve elements L80810P with proportional (ED4-PT1) control of Tank unloaded excess flow L80810P (ED4-PT1) RE 1801-1 Edition: 09.2016 Replaces: 07.12 01.2016 Size 6 Series 00 Maximum operating

More information

Operating instructions

Operating instructions Operating instructions Digital tank contents indicator DTA 10 DTA 10 DTA 10 0 4.0 m fuel oil 0 3.5 m water Read instructions before using device! Observe all safety information! Keep instructions for future

More information

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions Solar Thermal Grant Solar Pump Station Installation & Servicing Instructions Part No. DOC 96. Rev 02. October 2012 Important Note Important Note for Installers The Pump Station supplied with your Grant

More information

Boiler room components 0459EN October 2013 Safety pressure switch with manual reset

Boiler room components 0459EN October 2013 Safety pressure switch with manual reset 0459EN October 03 Safety pressure switch with manual reset Installation The lockout pressure switch must be installed by qualified personnel. The pressure switch K374Y00 can be assembled either vertically

More information

Bulk Solids Feeding. Blow-Through Rotary Valves RVS Drop-Through Rotary Valves RVC

Bulk Solids Feeding. Blow-Through Rotary Valves RVS Drop-Through Rotary Valves RVC Bulk Solids Feeding Available from: FILQUIP Pty Limited 5/6 Compton Rd, Underwood, Qld 49 Australia Ph: +6 7 308 3499 Fx: +6 7 308 3449 Email: sales@filquip.com.au www.filquip.com.au Blow-Through Rotary

More information

BALL VALVE - 340BA SERIES Pneumatic actuator - El-O-Matic

BALL VALVE - 340BA SERIES Pneumatic actuator - El-O-Matic C D E BALL VALVE - 30BA SERIES Pneumatic actuator - El-O-Matic FIGURE: PD: Pneumatic actuator, double acting PE: Pneumatic actuator, spring return G F DIMENSIONS: (mm) Ø DN C PD PE PD D E F Kg PE D E G

More information

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080

CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 CO 3-WAY PNEUMATIC VALVE INSTRUCTION MANUAL 2080 STI S.r.l has taken every care in collecting and verifying the documentation contained in this Instruction Manual. The information herein contained are

More information

Manual. Pneumatic Drilling Unit Series BEP 22 SK. Read this manual before installation and commissioning of the product. Keep for future reference.

Manual. Pneumatic Drilling Unit Series BEP 22 SK. Read this manual before installation and commissioning of the product. Keep for future reference. EN Manual Pneumatic Drilling Unit Series BEP 22 SK Read this manual before installation and commissioning of the product. Keep for future reference. MAN027 - Manual BEP 22 SK, EN, Rev. 01.doc Table of

More information

THE TOTAL SOLUTION PROVIDER

THE TOTAL SOLUTION PROVIDER THE TOTAL SOLUTION PROVIDER R R THE TOTAL SOLUTION PROVIDER DESCRIPTION The Full immersion Patented System consists of a round header tank with fully integrated diaphragm valves, suitable for Dust collector

More information

R35 GT-R GT1000 FULL TURBINE KIT INSTALLATION MANUAL

R35 GT-R GT1000 FULL TURBINE KIT INSTALLATION MANUAL R35 GT-R GT1000 FULL TURBINE KIT INSTALLATION MANUAL Installation must be done by a professional. Read this manual prior to the installation. Always have access to this manual as well as a factory service

More information

Backflushing Filter AutoFilt RF3

Backflushing Filter AutoFilt RF3 Backflushing Filter AutoFilt C 2,5 4 6 8 1. TECHNICAL SPECIFICATIONS 1.1 GENERAL The automatic back-flushing filter AutoFilt is a self-cleaning system for extracting particles from lowviscosity fluids.

More information

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life! Instructions and operation manual for butterfly valves This manual is intended to support the users of Herberholz butterfly valves type HRD/HRA, RD/RA, LDKE/LDKF for installation, operation and maintenance

More information

Freefall metal detection system Vistus with separator FL

Freefall metal detection system Vistus with separator FL Freefall metal detection system Vistus with separator FL The space-saving model Separator FL benefits For maximum space-saving: the low installation height allows for especially short complete systems

More information

SolidFlow. Monitoring of Solids. Product Information. SWR engineering Messtechnik GmbH

SolidFlow. Monitoring of Solids. Product Information. SWR engineering Messtechnik GmbH EN SolidFlow Product Information Monitoring of Solids SWR engineering Messtechnik GmbH Using SolidFlow is a sensor especially developed for measuring the flow rate of solids conveyed in metallic ducts.

More information

BUTTERFLY VALVE - N1234 SERIES Pneumatic actuator - Actreg

BUTTERFLY VALVE - N1234 SERIES Pneumatic actuator - Actreg B C D BUTTERFLY VALVE - N1234 SERIES Pneumatic actuator - Actreg FIGURE: AD: Pneumatic actuator, double acting AS: Pneumatic actuator, spring return G F L DIMENSIONS: (mm) DN L B AD AS AD C D F Kg AS C

More information

MAMMOUTH Type Series Booklet

MAMMOUTH Type Series Booklet Butterfly Valve MAMMOUTH DN 1050-4000 PS 25 bar Type Series Booklet Legal information/copyright Type Series Booklet MAMMOUTH All rights reserved. The contents provided herein must neither be distributed,

More information

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 EN Operating manual Motorised zone valve Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3 This manual ensures safe and efficient use of the 3PV2 or 3PV8 force-actuated three-way valve with spring-loaded return

More information

BR 31a Rack-and-pinion Actuator,

BR 31a Rack-and-pinion Actuator, Operating, assembly and maintenance instructions BR 31a Rack-and-pinion Actuator, SRP and DAP 1. General These instructions are intended to support the user in the assembly, maintenance, and repair of

More information

Service Handbook. High-Pressure Washer Pump

Service Handbook. High-Pressure Washer Pump Pump 629 9/28/01 3:22 PM Page 1 Service Handbook High-Pressure Washer Pump 3.532-629.0 10.00 Pump 629 9/28/01 3:22 PM Page 2 Pump 629 9/28/01 3:22 PM Page 3 TROUBLESHOOTING OVERVIEW How to Use This Manual

More information

BOAX-B Mat E. Type Series Booklet

BOAX-B Mat E. Type Series Booklet Butterfly Valve with Electric Actuator BOAX-B Mat E PS 16 bar: DN 40 to 200 PS 10 bar: DN 250 and 300 Design to EN 593 and ISO 10631 Type Series Booklet Legal information/copyright Type Series Booklet

More information

BABY S PRATIKA S VACUUM AUTOCLAVE

BABY S PRATIKA S VACUUM AUTOCLAVE MEDICAL EQUIPMENT DIVISION Via Don L. Sturzo,6 42021 Barco (RE) (ITALY) Codice Fiscale e Partita IVA: IT 01363800358 Numero REA: 180051 C.C.I.A.A. di Reggio Emilia Capitale sociale: Euro 10.400 i.v. Tel.

More information

Installation, Operating & Maintenance Instructions. UHV gate valve with pneumatic actuator. Series 108 DN mm (I. D. 2½ 8 )

Installation, Operating & Maintenance Instructions. UHV gate valve with pneumatic actuator. Series 108 DN mm (I. D. 2½ 8 ) Installation, Operating & Maintenance Instructions UHV gate valve with pneumatic actuator Series 108 DN 63 200 mm (I. D. 2½ 8 ) This manual is valid for the following product ordering numbers: 108.. -.

More information

solids solutions group

solids solutions group Pneumatic dense phase conveying by a push conveying process with high load and slow conveying speed for gentle conveying. Hygienic-Dry Design according to EHEDG-Guidelines for dry processes with dry cleaning,

More information

Operating Instructions for the. In Line Conveyor System West Cabot Boulevard Langhorne, PA w w w.empire-airblast.

Operating Instructions for the. In Line Conveyor System West Cabot Boulevard Langhorne, PA w w w.empire-airblast. Operating Instructions for the IL-885 In Line Conveyor System 2101 West Cabot Boulevard Langhorne, PA 19047-1893 w w w.empire-airblast.com Model Number: Serial Number: Date of Purchase: Date of Installation:

More information

METERING VALVE 2" STEM GUIDED

METERING VALVE 2 STEM GUIDED 2" STEM GUIDED All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be construed

More information

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : NOMINAL SIZE MATERIAL MAXIMUM SERVICE PRESSURE 200, 150, 100, 80 & 50NB Cast Iron 12 Bar (175 PSI) THREADED OPENING MOUNTING FACTORY HYDROSTATIC TEST PRESSURE

More information

AV INSTALLATION, OPERATION & MAINTENANCE MANUAL

AV INSTALLATION, OPERATION & MAINTENANCE MANUAL Rack & Pinion Pneumatic Actuators AV INSTALLATION, OPERATION & MAINTENANCE MANUAL AVCS PO Box 68172 Minneapolis, MN 55418 TABLE OF CONTENTS CHAPTER 1: PRODUCT DESCRIPTION 3 CHAPTER 2: TECHNICAL FEATURES

More information

6/2 ways/positions flow diverters L (VS120-VS125-VS129)

6/2 ways/positions flow diverters L (VS120-VS125-VS129) 6/2 ways/positions flow diverters L710... VS120-VS125-VS129) RE 18302-04 Edition: 05.2014 Replaces: 07.12 Size 4 Series 00 Maximum operating pressure 310 bar 4500 psi) Maximum flow 25 l/min 6.6 gpm) Ports

More information

PNEUMATIC TRANSPORT FOR SOLID FUELS Price list ADVANCE Easy Moving

PNEUMATIC TRANSPORT FOR SOLID FUELS Price list ADVANCE Easy Moving ADVANCE www.advanceeasymoving.com PNEUMATIC TRANSPORT FOR SOLID FUELS Price list 2015 INDEX Basic components - NOVA 1 vacuum unit page 2 - NOVA 2 vacuum unit page 2 - Control panel Drive page 2 - Dispenser

More information

SMALL FLOW AIRMATE PRESSURE REDUCING VALVES AND AIR LOADERS CLASSES A-2, AG-2, AF-2, AFG-2, ETC.

SMALL FLOW AIRMATE PRESSURE REDUCING VALVES AND AIR LOADERS CLASSES A-2, AG-2, AF-2, AFG-2, ETC. 50 Telecom Drive, Tampa Florida 33637 Installation, Operating and Maintenance Instructions Supplement 30/.5. Rev. SMALL FLOW AIRMATE PRESSURE REDUCING VALVES AND AIR LOADERS CLASSES A-, AG-, AF-, AFG-,

More information

4/3 and 4/2 Proportional directional valve elements L8580 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING

4/3 and 4/2 Proportional directional valve elements L8580 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING / and / Proportional directional valve elements L88 with flow (EDC-P) sharing control (LUDV concept) PATENT PENDING L88 (EDC-P) RE 181-9 Edition:.16 Replaces: 7.1 7.1 Size 6 Series Maximum operating pressure

More information

Installation and maintenance guide

Installation and maintenance guide Installation and maintenance guide METERING VALVE DAV 100 - DAV 200 DAV TECH SRL Via Ravizza, 30-3605 Montecchio Maggiore (VI) - ITALY Tel. 0039 0444 54510 - Fax 0039 0444 54324 davtech@davtech.it - www.davtech.it

More information

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE FEATURES The bronze ZEUS valve is intended for the automatic shutoff of networks of fluids. The full-bore inclined-seat body and the excellent flow-rate coefficients allow for very low pressure drops.

More information

Line filter with filter element according to DIN 24550

Line filter with filter element according to DIN 24550 Line filter with filter element according to DIN 2455 RE 51423/9.12 Replaces: 7.1 1/2 Type 445LEN4 to 1 Size according to DIN 2455: 4 to 1 Nominal pressure: 45 bar [6527 psi] Connection up to G 1 1/2;

More information

Freefall metal detection system Vistus with separator ST 2.0

Freefall metal detection system Vistus with separator ST 2.0 Freefall metal detection system Vistus with separator ST 2.0 Reliable metal detection ensuring optimum product quality Separator ST 2.0 benefits Dust-proof design for minimal product loss and increased

More information

Installation and Service Instructions (Translation of the Original Instructions) SV120. C _EN 11/2009 Rev.0

Installation and Service Instructions (Translation of the Original Instructions) SV120. C _EN 11/2009 Rev.0 Installation and Service Instructions (Translation of the Original Instructions) SV20 Introduction Carefully read these Installation and Service Instructions prior to the installation and start of operation

More information

6400 Series Horizontal Loading Valves

6400 Series Horizontal Loading Valves Leading The Way in Fluid Handling Solutions Worldwide 6400 Series Horizontal Loading Valves Document No. H32310PA, Rev. 0 Issue Date: February 19, 2015 Supersedes: September 9, 2013 The OPW Horizontal

More information

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide 11451 Belcher Road South, Largo, FL 33773 USA Tel +1 (727) 447-6140 Fax +1 (727) 442-5699 1054-7 / 34405 www.onicon.com sales@onicon.com

More information

AKG-A/AKGS-A. Type Series Booklet

AKG-A/AKGS-A. Type Series Booklet Gate Valve AKG-A/AKGS-A PN 63-160 DN 80/80-300/250 Type Series Booklet Legal information/copyright Type Series Booklet AKG-A/AKGS-A All rights reserved. The contents provided herein must neither be distributed,

More information

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1 INLINE Flow sensor for hazardous area II G/D - II D - II GD - I M Type SE0 Ex can be combined with... Flow meter with NAMUR or NPN/PNP output signal Mounting, dismounting of electronics by a Quarter-Turn

More information

OPD min max a c max d c. code [ISO 228 G] [mm] [l/min] [barg] [barg] [barg] code [Volts/Hz]

OPD min max a c max d c. code [ISO 228 G] [mm] [l/min] [barg] [barg] [barg] code [Volts/Hz] 2/2 way pilot operated PISTON valve, G 1/4ʺ G 1/2ʺ A P normally closed TECHNICAL SPECIFICATIONS Media: water, steam Media temperature: +80 C +180 C Ambient temperature: -10 C +70 C Body material: brass

More information

Features PNEUMAT IC VALVES. Pneumatic valves Vip - Pneumatic coaxial valve GENERAL FEATURES CONTROL MEDIA OPERATING MEDIA

Features PNEUMAT IC VALVES. Pneumatic valves Vip - Pneumatic coaxial valve GENERAL FEATURES CONTROL MEDIA OPERATING MEDIA OMAL S.p.a. Via Ponte Nuovo, 11-25050 Rodengo Saiano (BS) ITALY Phone +39 0308900145 - Fax +39 0308900423 Booked in the Enterprise Register of: Brescia number 1661640175 Share capital completely deposited:

More information

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE VMH Safety shut off valves for gas with hydraulic actuator DN65 DN200 www. delta-elektrogas.com EE168-0513 VMH Contents Description.. 3 Features.. 3 Functioning and application. 4 Special versions and

More information

Installation and Setting-Up Instructions

Installation and Setting-Up Instructions Man.rev.1 Installation and Setting-Up Instructions Contents : 1 TECHNICAL DATA 2 CONSTRUCTION AND OPERATION 3 INSTALLATION 4 SETTING-UP 5 MAINTENANCE DOCUMENTS Technical Specifications : G345 Installation

More information

Operating & Maintenance Manual Compact Domestic Booster Set Model BTAF Arrow Valves

Operating & Maintenance Manual Compact Domestic Booster Set Model BTAF Arrow Valves Arrow Valves Ltd Tel 01442 823123 Fax 01442 823234 Installation Instructions/ Operating & Maintenance Manual Pent-A-Boost Compact Domestic Booster Set Models BTAF 700 900 1200 230-240 V Single Phase &

More information

The company 1 Certifications 2

The company 1 Certifications 2 PNEUMATIC ACTUATORS PRISMA MECÁNICA S.L The company 1 Certifications 2 ALUMINIUM PNEUMATIC ACTUATORS Technical features 3 PA range 5 P range 7 Disassembly and materials 9 PA dimensions 11 P dimensions

More information

Components for central heating

Components for central heating 01 01 Components for central heating Booster units and spare parts 18 Hydraulic separator and spare parts 21 Dirt separators - Deaerators 23 By-Pass differential valve - Air separator units 32 Filling

More information

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc. TREATER VALVE All Rights Reserved. All contents of this publication including illustrations are believed to be reliable. And while efforts have been made to ensure their accuracy, they are not to be construed

More information

ABV21i and ABV40i Air Actuated Boiler Blowdown Valves

ABV21i and ABV40i Air Actuated Boiler Blowdown Valves Local regulations may restrict the use of this product to below the conditions quoted. In the interests of development and improvement of the product, we reserve the right to change the specification without

More information

PRATIKA S / N AUTOCLAVE

PRATIKA S / N AUTOCLAVE FAX NR. 0039 0522 875579 E-MAIL: reverberisrl@gmail.com REVERBERI ARNALDO S.R.L Via Don Luigi Sturzo n 6 42021 Barco di Bibbiano Reggio Emilia ITALY Tel. 0039 0522/875159 Numero REA: 180051 C.C.I.A.A di

More information

Service Handbook HD /97

Service Handbook HD /97 Service Handbook HD 1050 5.905-032 07/97 Foreword HD 1050 Foreword Indispensable prerequisites for the competent execution of service procedures are comprehensive, real-life training workshops for technical

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS RTECK terminal boxes RTKB series IEC Ex EX010 TECHNICAL FILES CONTENTS: 1) Contents 2) General information 3) Safety information 4) Conformity to standards 5) Function 6) Technical

More information

Model LA 4100 Time Delay OFF Controller

Model LA 4100 Time Delay OFF Controller ISIMET LA Series Model LA 4100 Time Delay OFF Controller Installation, Operation and Maintenance Manual Application: The Time Delay OFF Controller operates as a single output controller where the application

More information

The Combustex Pilot Pro 800 Pilot Burner Assembly with Ignition & Flame Failure Monitor

The Combustex Pilot Pro 800 Pilot Burner Assembly with Ignition & Flame Failure Monitor OPERATIONS MANUAL The Combustex Pilot Pro 800 Pilot Burner Assembly with Ignition & Flame Failure Monitor Safe, reliable ignition and flame failure protection combined with a proven, completely self-powered

More information

Block mounting filter, for lateral flange-mounting

Block mounting filter, for lateral flange-mounting Block mounting filter, for lateral flange-mounting RE 51418/12.1 Replaces: 1.1 1/18 Type 245PSFN4 to 4; 245PSF13, 15 Size according to DIN 2455: 4 to 4 Additional sizes: 13, 15 Nominal pressure 25 bar

More information

L15 HEAVY DUTY KNIFE GATE VALVE STANDARD PARTS LIST

L15 HEAVY DUTY KNIFE GATE VALVE STANDARD PARTS LIST L15 HEAVY DUTY KNIFE GATE VALVE The L15 model knife gate is a uni-directional lug type valve designed according to MSS-SP-81 and TAPPI TIS 405-8 for industrial service applications. The design of the body

More information

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive

Installation and Operation Instructions. VAG ROTOP Portable Electric Drive Installation and Operation Instructions VAG ROTOP Portable Electric Drive KAT-B 5551 Edition 1-01/2018 Content 1 General 3 1.1 Safety 3 1.2 Proper use 3 2 Transport and Storage 3 2.1 Transport 3 2.2 Storage

More information

STAINLESS STEEL PRESSURE REDUCING VALVE PRV ELITE

STAINLESS STEEL PRESSURE REDUCING VALVE PRV ELITE Pressure (bar) STAINLESS STEEL PRESSURE REDUCING VALVE PRV ELITE MAIN CHARACTERISTICS The stainless steel PRV elite valve is intended for the function of pressure reduction of the fluids such as water,

More information

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE FEATURES The stainless steel ARES valve is intended for the automatic shut-off of networks of fluids. The full-bore, inclined-seat body and the excellent flow-rate coefficients allow for very low pressure

More information

type 630r relief Valve

type 630r relief Valve December 2011 type 630r relief Valve W1934 Figure 1. Type 630R Relief Valve Introduction The Type 630R is a general relief valve that is available in NPS 1 and 2 / DN 25 and 50 body sizes. It is frequently

More information

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D.

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D. Installation, Operating & Maintenance Instructions HV gate valve with pneumatic actuator Series 110 DN 250 320 mm (I. D. 10" 12") This manual is valid for the following product ordering numbers: 11048-.

More information

KEYSTONE F89 PNEUMATIC QUARTER-TURN ACTUATOR GENERAL PURPOSE / HAZARDOUS AREA

KEYSTONE F89 PNEUMATIC QUARTER-TURN ACTUATOR GENERAL PURPOSE / HAZARDOUS AREA FEATURES Direct mounting to all Keystone butterfly valves and ball valves. Valve connection compatible with Keystone (imperial and metric) and ISO 5211. Double Rack and Pinion design nullifies side loads

More information

6/2 ways/positions flow diverters L (VS151-VS152-VS155)

6/2 ways/positions flow diverters L (VS151-VS152-VS155) 6/2 ways/positions flow diverters L721... (VS151-VS152-VS155) RE 1832-5 Edition: 2.216 Replaces: 5.214 Size 6 Series 1 Maximum operating pressure 31 bar (45 psi) Maximum flow 6 l/min (15.85 gpm) Ports

More information

4/3-4/2 Proportional directional valves L5080 solenoid (LC04P) operated (for open loop control) L5080 (LC04P)

4/3-4/2 Proportional directional valves L5080 solenoid (LC04P) operated (for open loop control) L5080 (LC04P) / - / Proportional directional valves L solenoid (LCP) operated (for open loop control) L (LCP) RE - Edition:. Replaces: 7. 7. Size Series Maximum operating pressure bar ( psi) Maximum flow l/min (.7 gpm)

More information

+Actuators GEMELS PNEUMATIC ACTUATORS. Actuators. INSTALLATION, OPERATION AND MAINTENANCE TECHNICAL DETAILS Quarter-Turn Rack & Pinion

+Actuators GEMELS PNEUMATIC ACTUATORS. Actuators. INSTALLATION, OPERATION AND MAINTENANCE TECHNICAL DETAILS Quarter-Turn Rack & Pinion +Actuators + GEMELS PNEUMATIC ACTUATORS INSTALLATION, OPERATION AND MAINTENANCE TECHNICAL DETAILS Quarter-Turn Rack & Pinion Actuators + Actuators Specialist in Ball Valves Introduction STANDARDS Gemels

More information